DESCRIPTION
Master-Trol is a electronic water management software system used to regulate water usage, provide complete control over the use of water fixtures in a facility and provide reports on water consumption. For more information, please visit www.acorneng.comTRANSCRIPT
and other Acorn Electronic Valve Systems
Rev June 09R
Headquartered in Southern California
Acorn Engineering –Innovator of Engineered Plumbing Products
Acorn Family of CompaniesDiversity in Plumbing Products
Acorn Engineering and its Family of Companies are members of U.S. Green Build Council
Master-Trol is a electronic water management software system used to regulate water usage, provide complete control over the use of water fixtures in a facility and provide reports on water consumption.
Master-TrolMeans Total Control
Complete controlover showers
Complete control over lavatories
Complete control over toilets
Master-TrolMeans Total Control
Any plumbing fixture!
• Water savings by regulating the amount of water used
• Effortless installation and maintenance
• Complete control of up to 3,072 fixtures on a single system
• Monitors water usage by reports, graphs and charts
• Continuous improvement since initial development in 1991
Master-TrolBenefits
• Minute by minute reports of users activities on the system
• Easy navigation with detailed location descriptions and search
• Real time reporting of usage time and valve status
• Prevention of abuse of fixtures and/or usage of water
• Use of Master-Trol can contribute to LEED Points
Master-TrolBenefits
Master-TrolHardware Components
The Master-Trol system hardware consists of the following:• Acorn Master-Trol 12-Station Controller• Windows XP Desktop Computer with 8-Link PCI card (recommended from Acorn)
• 8-port Serial Cable• 6 Conductor Telephone Cable (Data Link)• 6 Conductor Telephone Cable (Station Wire)
The Master-Trol Electronic Valve Controller has 12 ports for 12 solenoid valve connections.
Master-TrolElectronic Valve Controller
8 Versa Link Network Module
32 Controllers per Versa Link
12 Valves per controller
= 3,072 total valves controlled by one server
From a single source
you can control up to 3,072 valves
Server
LocalArea
Network
User Interface
Master-TrolControls up to 3,072 Valves
= 3,072 total valves controlled by one server
Master-TrolControls up to 3,072 Valves
Like any server, provides connection to a network of users
= 3,072 total valves controlled by one server
Master-TrolControls up to 3,072 Valves
Server can connect to a maximum of eight Master-Trol controllers in remote areas in the facility.
= 3,072 total valves controlled by one server
Master-TrolControls up to 3,072 Valves
Each Master-Trolcontroller can be daisy chained for a maximum of 32 controllers.
= 3,072 total valves controlled by one server
Master-TrolControls up to 3,072 Valves
Each Master-Trolcontroller can connect to a maximum of 12 valves
12 valves
= 3,072 total valves controlled by one server
Master-TrolControls up to 3,072 Valves
32 x 12 valves = 384 valves
= 3,072 total valves controlled by one server
Master-TrolControls up to 3,072 Valves
8 x 384 valves = 3,072 valves
Link 8 Link 7 Link 6
Link 5 Link 4
Link 3 Link 2
Link 1
Up to 32 Master-TrolControllers per Link(1,220 Meters per Link)
Server or
Handheld
120/230/24 VAC, 60 Hz hardwired transformer is provided
Master-TrolOverall System Set-Up
Up to 4,000 ft
Controller
ValvesController
Valves
Controller
Valves
TRIANGULAR CHASE IN PRISON APPLICATION
Typical Chase
An Acorn Technician Assists with Setup
Open Chase
Master-Trol12 valves per controller
When the push buttona signal is sent
to the branch box
The signal then travels to theMaster-Trolcontroller, which identifies the station sendingthe signal and automaticallyreviews all preprogrammed options and timing requirements
If authorized, the controller returns signalactivating the valve and releasing water to the fixture
Master-TrolHow the System Works
Shown above in a Prison Comby (lav/toilet) application. Process is similar for all valves
Master-TrolNew Enhancements 2008
Master-Trol has been tried and tested over 20 years. It is used in a wide variety of applications from Super Max prisons to regional county jails all over the world.
Significant Improvements for computerized systems::• Windows explorer “Tree” view with improved description of fixture locations and increased flexibility in mapping of fixtures to Master-Trol stations• Multi-Level user names and passwords with detailed tracking of user activities• Ability to limit the amount of usage time and/or number of activations on a fixture in a 24-hour period providing unparalleled water saving• Real time monitoring of water usage and daily/weekly/monthly reports • Added modes such as Accumulator Mode, Variable Lockout, Queued Activations and many more
Master-TrolServer Program
The Master-Trol Server Program is the first layer of the Master-Trol computerized system which communicates directly with the Master-Trol Controllers
The Master-Trol Server program serves the following purposes:• Gives the number of active controllers connected to each link in the Master-Trol System• Provides information of the Link Status• Allows remote access• Displays list of client computers which have access the system.
Master-TrolServer Program
This window could be used to display any controller on any link not communicating with the server
orClicking on a "link" above could pop up a status map of all controllers on the link.
Master-TrolConfiguration Program
• Create the “tree” structure for the prison facility, with detailed descriptions and labels for the location of each valve
• Map the created valves in the tree structure to desired stations of a controller on the Master-Trol System
Master-TrolConfiguration Program
• Create users for the Master-Trol System - Add/Delete users and authorize users access to Master-Trol Software Modules
• Limit the visibility and the access to change parameters to specific users in a specific region in the facility.
• Set accessible functions for the created user to operate• Monitor each users activities over a period of time:
single day, group of days, month etc.
Master-TrolClient Program
Tabbed structure for easy navigation
Master-TrolClient Program
Variable Lockout Custom setting for stations, when a specified numberof activations occur with in a specified time period the station is locked out for a specified interval
Accumulator Mode Used to configure a station to operate with Acorn Vac vacuum drainage system
Paired Operation Used when the valve is required to automatically operate in conjunction with another station on the Master-Trol Controller
Master-TrolClient Program
Make parameter changes to valves such as Setting Valve on time, Lockout time between activations or remote operation of the valve from the central PC workstation
Setting Valve modes as:• Single Cycle – Valve will run through timing cycle before shutting off• Cycle Interrupt – User can interrupt timing cycle by pushing the actuator during a timed cycle
Master-TrolClient Program
• Enabling/Disabling a single valve and/or all valves in a cell/area or the whole system to prohibit utilization of any fixtures in that area/facility
• Setting a limit to the amount of water utilized and/or flush activations in a 24 hour period of time
• Setting windows of operation wherein the fixtures are available for use only within the set period and disabled outside of the specified window.
• View real time usage of the fixture
• Automatic cycling a fixture after an adjustable period of non-use has passed to prevent the trap from drying and/or corrosion of the ht fixture
Master-TrolClient Program
• View a color coded representation of all fixtures in the facility and monitor via color codes in real time
• Get real time warnings of any non-communicating fixtures/controllers and any disabled stations or stations in a remote operation condition
Master-TrolClient Program
• Ability to connect to a Server from a single or multiple clients using a LAN/WAN connection
• Allows administrators/ maintenance personnelto monitor the system and make changes from remote locations
• Dual levels of security via the Server Software and Configuration Software to prevent unauthorized access.
Master-TrolLogging Program
• Log system events to a file on the computer for archiving
• Records number of times each valve has been activated
• Total ON time for each valve
• Log gallons/liters of water used per link/valve/all links over a selectable period of time
Master-TrolLogging Program
• When valves are enabled and disabled
• Print a hardcopy of the information in a log file for archival
• Sort through log files and selectively plot requested data on screen and on hardcopy
Master-TrolHandheld Programmer
• The Master-Trol controller station parameters can also be set using the Acorn Handheld programmer (-CPT)
• CPT is a low cost alternative to using a PC and has the ability to connect to and control one full link (32 controllers) at a time
• The CPT is recommended for smaller installations - between 1-5 controllers.
• Get information on number of controllers on different links
• Set/change On/Off times• Enable /disable stations
Master-TrolHandheld Programmer
• Set Valve modes Remote Operation, Paired Operation (PO)
• Set Actuator Modes Single cycle (SC), Cycle Interrupt (CI), Accumulator Mode (AM)
• Troubleshoot and set parameters when access to the central Desktop Computer is not easily available or Master-Trol Controllers are to work stand alone.
Green ProductWater Conservation
LEED Point Potential Under Water Efficiency Section
• LEED for New Construction
• LEED for Commercial Interiors
• LEED for Existing Buildings
• LEED for Healthcare
• LEED for Schools
Water Efficiency Section
Innovative Wastewater Technologies
Water Reduction: 20- 40% Water Conservation
Achieve LEED certification
Green ProductWater Conservation
Vacuum Plumbing System
Master-TrolElectronic Water
Management System
Green ProductWater Conservation
Completed ProjectsSmithsonian - Washington, DCFlexible DesignWater Management Control
Western Virginia Regional Jail – Salem, VAEmployed Innovative Wastewater TechnologiesLEED Certified BuildingWater Reduction: 20 - 40%
Smithsonian Museum of Natural HistoryWashington, DC
Green ProductWater Conservation
Renovation SolutionsAddressed concerns with:– Structural limitations– Restrictive site issues– Embedded contaminants
Green ProductWater Conservation
Western Virginia Regional Jail
One of the 1st LEED qualified prisons in the US
Estimated savings up to 4 million gallons of water savings and sewage reduction
Western Virginia Regional Jail Plumbing Fixtures
Green ProductWater Conservation
Time-TrolValve Controller
Time-TrolValve Controller
Time-TrolValve Controller
Time-TrolValve Controller
Time-TrolValve Controller
Time-Trol PlusBattery Powered Valve Controller
Time-Trol PlusBattery Powered Valve Controller
15 Second Pushbutton Electronic Metering
Touch-Trol 15 Second Metering Valve