Date: 4 & 5th June 2010End User: BSNL Kerala Circle , Trivendrum Installer: MillikenVenue: StachueTelephone Exchange, TrivendrumClassification: Overlay
Amit DubeyMaxCell Market Manager - India
BSNL Trivendrum (India)
Installed Rope in 110-100mm Cable Installation EM
5621-3 MaxCell in 110-100mm duct overlay of 40-33mm duct
Section Conduit ID, mm
Existing Cable or sub duct OD mm
Pull Length
M
Sweeps, degrees
MaxCell Installations Cable Installation Final Fill
RatioStyle Time, min
Tension, kgs
OD, mm Time, min
Tension, kgs
1 100mm, 33mm
40 duct, empty
100, 100
Straight, straight
1x5621-3, 1x 3614-2
4, 5
1 Man
2 Man Hand Pull
18, 2 x
12mm
6, 6,8
2 Man HP 19.2%26.4 %
Remarks:-
- This trial was held in exchange compound because it required permission to open manhole and mainly because of coastal area and monsoon season all manhole were fill up with water.
- Formed a 100m lengthy 110-100 mm conduit, do sub-ducting with 40-33mm HDPE pipe .
- Overlay EM 5621-3 MaxCell in 110-100mm conduit, further installed EM 3614-2 MaxCell in empty 40-33 mm sub duct.
- Installed 18mm cable in EM 5621-3 MaxCell while 2 x 12mm in EM 3614-2 MaxCell in 40-33mm sub-duct successful.
- Concern BSNL Kerala Circle Chief General Manager (CGM) and his team agreed to discussed MaxCell application in monthly management meeting and to identify such site where duct is full and expansion and upgradation required in same route.
Date: 4 & 5th June 2010End User: BSNL Kerala Circle , Trivendrum Installer: MillikenVenue: StachueTelephone Exchange, TrivendrumClassification: Overlay
Amit DubeyMaxCell Market Manager - India
Installation Results:
Date: 4 & 5th June 2010End User: BSNL Kerala Circle , Trivendrum Installer: MillikenVenue: StachueTelephone Exchange, TrivendrumClassification: Overlay
Sub- ducting via 40-33mm in 110-100mm conduit
12mm Cable getting entry in 40-33mm sub duct
Amit DubeyMaxCell Market Manager - India
18mm cable getting enter in EM 5621-3 MaxCell 18mm cable pulling in EM
5621-3 MaxCell
Date: 4 & 5th June 2010End User: BSNL Kerala Circle , Trivendrum Installer: MillikenVenue: StachueTelephone Exchange, TrivendrumClassification: Overlay
Cable pulling in 40-33mm duct
Thanks for CGM Kerala Team
Amit DubeyMaxCell Market Manager - India
2nd Cable pulling in 2nd cell of EM 3614-221-3
MaxCell sub duct 40-33mm