maxsys - dsc

12
High-End Integrated Security from DSC MAXSYS ®

Upload: others

Post on 21-Oct-2021

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MAXSYS - DSC

High-End Integrated Security from DSC

M A X S Y S ®

Page 2: MAXSYS - DSC
Page 3: MAXSYS - DSC

M A X S Y S

C O M P R E H E N S I V E S E C U R I T Y

T H A T ’ S N O T C O M P L I C A T E D

Managing a business takes a lot of work, passion and commitment.

That’s why it’s important that the same effort be made when choosing

a security system. After all, properly protecting the people and other

valuable assets that comprise a successful business are not something

you want to jeopardize.

There was a time when building security consisted of little more than burglar

alarms, motion detectors and a few smoke detectors. Clearly times have

changed and the need for a premium security system is real.

In keeping with new times and new technologies, DSC has defined the meaning

of security, as is evident with MAXSYS. The security system allows a host of

value-added and life-safety features to be integrated to provide peace of mind

for years to come. Security concerns, whether they are intrusion, fire, alarm

communications, access control, automation, wireless/addressable expansion or

structured cabling, can be tailored to meet specific needs. MAXSYS is truly a

single-system solution that is ideal for commercial, industrial and institutional

facilities, as well as large or multi-level residential units.

Fully integrated security solutions

High-end, premium quality security

ss

Page 4: MAXSYS - DSC

M A X S Y S

I N T R U S I O N C O N T R O L P A N E L S

Every business is unique. With MAXSYS you

can choose the best combination of

technologies to expand security needs

as necessary.

COMBUS expansion

Addressable loop expansion

Wireless expansion

16-128 Zone Control Panel PC4020

• 16 zones on main control panel • Supports up to 16 hardwired keypads • Expandable to 128 zones using hardwire,

wireless modules and addressable zones • COMBUS hardwired expansion • 8 partitions • 1,500 user codes (4 or 6 digit)• 3,000-event buffer • 9 account and 3 phone numbers • 1 supervised bell zone • Built-in telephone line and siren

supervision• Auto SIA and Contact ID formats• Supports GS3050-A/GS3050-I GSM

universal wireless alarm communicatorsand T-Link™/T-Link TL250 network/Internetalarm communicators

• Full upload/download support with DLSdownload software

K E Y P A D S

The MAXSYS LCD keypad puts security and

convenience at your fingertips. The keypad offers

end-users simple one-button activation of five

programmable function keys. For urgent situations,

keypad-activated emergency keys send an alarm

signal to the central monitoring station, which in

turn, notifies the proper authority (police, fire or

emergency services).

Programmable-Message LCD Keypad LCD4501

• Connect up to 16 keypads • Large, backlit, 2-line, 32-character display • Plain-language display of zone status, system

status, trouble conditions, event buffer,system instructions, date and time

• Ready, Armed and Trouble LEDs • 5 programmable function keys • 4 keypad-activated alarms:

- Panic, Auxiliary, Fire and Duress

• Backlight boost

ss

s

Page 5: MAXSYS - DSC

Internet Alarm Communicator T-LINK TL250

T-Link TL250 Internet alarm communicators providean always-on, two-way line of IP communicationbetween DSC control panels and central monitoringstation receivers. It works over the Internet or local LAN/WAN networks and installs easily,even behind firewalls.

Network Alarm Communicator T-LINK

Low-cost T-Link network alarm communicatorstransmit alarm signals securely over an existingLAN/WAN network and then through the Internet toa central monitoring station. This is an idealapplication for banks or large retail chains wheresignificant networks have already been establishedand are being used for various purposes.

GSM Universal Wireless AlarmCommunicators GS3050-A:

• Compatible with any control panel • 4 inputs for the activation of voice messages and

SMS dialer (optional NC2/VOX voice board modulerequired for voice dialer)

• 2 SMS messages available on each input • Programmable voice/SMS dialer-channel activation• 8 telephone numbers available for the voice/SMS

dialer function • 5 outputs (open collector) • Output control via SMS messaging • Dual-band (900 MHz and 1,800 MHz

GSM networks) • SIM card (not included) programmable via any

GSM cellphone or PC with the Windows™

compatible GS3050-A Software Application• Compatible with standard central monitoring

station receivers, like Sur-Gard™

• 7-segment status display• Supports Contact ID, 10 bps and 20 bps protocols,

and in areas with optimum signal strength, SIAand CESA protocols

GS3050-I:

The GS3050-I includes all of the same features as the GS3050-A, with the following exceptions.• Dual-band:

- I version (850 MHz/1,900 MHz networks) - IW version (900 MHz/1,800 MHz networks)

• 4 outputs (open collector)• Optional NC2/VOX voice board module is

not available• Not equipped with 7-segment status display• Includes GS3050-I Software Application

• Multiple receivers for larger coverage area or overlap

• New technology for greater signal range and accuracy

• Long-life lithium batteries • Attractive, compact designs• Easy to install, program and use

W I R E L E S S E X P A N S I O N

Use the PC4164-433 wireless receiver to support

up to 64 wireless zones and 16 wireless keys.

Up to eight backup receivers can be installed on

one system. Choose wireless devices from the

innovative line-up of DSC wireless solutions.

I N T E R N E T & N E T W O R K

A L A R M C O M M U N I C A T O R S

The award-winning DSC T-Link family of Internet

and network alarm communicators saves customers

money by taking advantage of their existing

Internet/Intranet networks to create fully supervised

security solutions between protected premises and

the central monitoring station.

G S M A L A R M C O M M U N I C A T I O N S

GSM universal wireless alarm communicators are an

effective backup or alternative to traditional

telephone lines and work by connecting the alarm

control panel to the GSM network to provide

protection against accidental line cuts.

M A X S Y S

Page 6: MAXSYS - DSC

M A X S Y S

A D D R E S S A B L E L O O P E X P A N S I O N

The Addressable Multiplexed Loop (AML) provides the ultimate in simple, flexible and affordable zone

expansion. Save time and money by connecting any addressable detector anywhere on the two-wire AML loop

to create up to 128 addressable zones.

Addressable Passive Infrared Detector AMB-300

• Based on the Bravo® 3 hardwire motion detector• Patented MLSP (Multi-Level Signal Processing)• Interchangeable lenses:

-Wall-to-wall lens (standard), curtain

lens, pet-immune lens and corridor lens

• Built-in tamper switch

Addressable Pet-Immune Passive Infrared Detector AMB-600

• Based on the Bravo® 6 hardwire motion detector• Patented MLSP (Multi-Level Signal Processing)• Provides pet immunity up to 85 lbs (38 kg)• Built-in tamper switch

Addressable Ceiling-Mount Passive Infrared Detector AMB-500

• Based on the Bravo® 5 hardwire motion detector• Patented MLSP (Multi-Level Signal Processing)• Coverage diameter based on mounting height• Built-in tamper switch

Addressable Glassbreak DetectorAMA-100

• Based on the AcuityTM hardwire glassbreak detector

• Detects all types of breaking glass-Plate, laminated, safety and tempered

• Can be tested using the glassbreaksimulator (AFT-100)

• Built-in tamper switch

Addressable Photoelectric Smoke Detectors FSB-210 SERIES

• Automatic drift compensation• Easy-maintenance removable smoke chamber• Non-contact sensitivity reading with

handheld test meter (FSD-100)• Self diagnostics• UL listed

Addressable Point / Contact Modules AMP-700 / AMP-701 / AMP-701NP / AMP-702 / AMP-704 / AMP-704F

• AMP-700 door/window contact with built-in reed switch

• AMP-701 door/window contact with normally closed input

• AMP-701NP universal addressable point module• AMP-702 fire point module with normally

open, EOL resistor supervised input • AMP-704 4-zone door/window contact with normally closed,

single or double EOL inputs• AMP-704F 4-zone normally open fire input module

Loop Repeater / Isolator Module AMX-400

• Can be used to repeat and re-power the AML loop to allow for longer wire runs:- Requires 12 VDC power source

• Will isolate the wire run in the event of a problem• Adds additional 170 mA

Loop Isolator Module AML-770

• Can be used to isolate burglary detectors from fire detectors on the same wire run

Page 7: MAXSYS - DSC

M A X S Y S

D A T A I N T E R F A C E M O D U L E S

With the installation of data interface modules (PC4401), MAXSYS control panels are able to interface with

leading manufacturers of home and building automation products and audio distribution systems to create

seamless, fully integrated control solutions.

Data Interface Module PC4401

• Connect up to 4 modules• Capable of performing as either a bi-

directional RS-232 interface, PC-Link isolator, printer module or DVACS®*communicator (Canada only)

M O D U L E S

MAXSYS zone expanders can add eight zones or 16 zones where needed. Simply connect them to the COMBUS

for flexible, efficient and distributed zone expansion.

8 /16 Hardwire Zone Expanders PC4108A / PC4116

• PC4108A adds 8 hardwire zones• PC4116 adds 16 hardwire zones• AUX power rated at 250 mA

(PTC protected)

Power Supply/ Relay Output / COMBUS Repeater ModulePC4204CX

• Connect up to 16 modules• Fully supervised for AC failure,

low battery and AUX failure• 4 programmable form ‘C’ relays:

- Rated at 3 Amps @ 12 VDC

P O I N T & G R A P H I C A N N U N C I A T O R S

When emergencies occur, make certain operating and emergency personnel are able to understand the nature

of an alarm and are able to communicate the information needed for swift and effective action. With MAXSYS

point or graphic annunciators important, context-sensitive information is never more than a glance away. The

annunciators can display up to 144 zone, partition and system events.

32 / 64 Point & Graphic AnnunciatorsPC4632 / PC4664

• Egg-crate backplate for flexible LED locations• Pre-printed point display transparency• Clear transparencies (2) for custom graphics

• Real-time zone status • Fully programmable • 4-wire hook-up to COMBUS• FCC and IC listed

* DVACS is a registered trademark of Electro Arts Ltd. Scarborough, Ontario, Canada.

16-Output ModulePC4216

• Provides 16 programmable outputs:- Rated at 50 mA @ 12 VDC

• Connect up to 9 PC4216 modules per system

Page 8: MAXSYS - DSC

M A X S Y S

M A X S Y S F I R E P R O D U C T S

MAXSYS fire products provide all the equipment

needed to integrate full commercial fire into any

security application. MAXSYS fire products are only

approved for North American regulations.

PC4020CF LCD4521 PC4701 PS4350R PC4204CXCF PC4702BP

Commercial Fire Panel PC4020CF

• Includes all the features of the PC4020 plus:- PC4050CR cabinet

- PC4701 module

- Built-in 16 VAC, 40 VA transformer

Programmable Fire-Message LCD Keypad LCD4521

• Includes all the features of the LCD4501 keypad• Red bezel• Fire function keys:

- Silence Trouble, Silence Bells, Fire Reset, Fire Drill

and Lamp Test

Dual-Line Dialer Module PC4701

• Dual, supervised phone line connections• 1 2-wire Class B/Style B supervised

smoke alarm zone• 1 Class B/Style B waterflow zone• Fire alarm and fire trouble form ‘C’ relays

External Battery ChargerPS4350R

• Includes PS4085 multi-rate charger module• Includes PT1012 transformer, 12 VDC, 160 VA• Space for 60 Ah of rechargeable batteries

Commercial Fire Power Supply PC4204CXCF

• Includes all the features of the PC4204CX• Includes PC4052CR cabinet • Built-in 16 VAC, 40 VA transformer

Dual-Zone Bell Panel PC4702BP

• Connect up to 4 modules• Provides 2 alarm notification circuits:

- Rated at 1.8 Amps @ 24 VDC each

• Fully supervised outputs for open, short and ground fault

• PTC protected• Includes:

- PC4052CR red cabinet

- 28 VAC, 180 VA transformer

Page 9: MAXSYS - DSC

M A X S Y S

2-Reader Access Control Module PC4820

• Connect up to 16 modules• Multiple reader technologies• 2 supervised lock outputs:

- 250 mA per output

• 64 user access levels• 99 date schedules• 4 holiday groups• Arm/Disarm partitions via access control• PC4053 beige cabinet included

A C C E S S C O N T R O L

Monitoring and restricting the individual entry of tens or

perhaps a thousand people within a building is not easy. To

protect it from theft or damage, MAXSYS allows simple and

affordable access control integration with its alarm systems.

Readers• MAXSYS supports a wide range of 26-bit Weigand readers:

- Polaris™, ioProx™, Shadowprox™, HID and Kantech XSF Technologies

M A X S Y S A C C E S S C O N T R O L K I T

This affordable package is the perfect access control

starter kit. It has all the essentials you need: control

panel, access control module, reader and keys in one

low-cost package. And, if needed, the system can be

easily expanded.

• 1 PC4020 control panel • 1 PC4820 access control module • 1 P225W26 ioProx reader• 10 P40KEY ioProx dual-encoded

proximity keys

Request-to-Exit DetectorT-REX™

• Passive infrared request-to-exit detector with patented X-Y Targeting™ and DSP (Digital Signal Processing)

Page 10: MAXSYS - DSC

M A X S Y S

Telephone Interface & Automation Control Module ESCORT™ 4580

• Turns any touchtone telephone into a talking keypad

• Programmable labels:- 6 words per label

- 240+ word library

• Built-in X-10 interface:- Supports up to 32 X-10 devices

- 16 schedules, 8 modes

• Available in English, Spanish and French

C O N C O U R S E EE XX PP ™ S T R U C T U R E D C A B L I N G

ConcourseEXP is the best value in residential structured

cabling. It provides new home builders and home-system

integrators with the convenience of a single, comprehensive

family of cable management products that are easy to use in

applications of all sizes and complexity. ConcourseEXP

enclosures and low-voltage modules have been designed to

provide seamless integration with MAXSYS control panels

and modules.

H O M E A U T O M A T I O N

Imagine a security system that controls home lighting automatically. With MAXSYS control panels lights can

be programmed to automatically turn on and off according to a daily, weekend or monthly schedule. These

tasks can be controlled by turning any touchtone phone into a fully functional keypad that can be used to

monitor and control a security system from home or from anywhere in the world.

D L S 2 0 0 2 S A S Y S T E M A D M I N I S T R A T O R ™ S O F T W A R E

DLS2002SA System Administrator software is the perfect solution for large or multi-location business

applications using the MAXSYS control panel. The software is simple to use and gives users the ability to view

and change codes, access cards and schedules, as well as view system status, arm/disarm partitions, and view,

sort and print the event buffer. The software can be found in the Products area of the DSC website under the

password-protected software section.

Page 11: MAXSYS - DSC

M A X S Y S ®

I N T E G R A T E D S Y S T E M S T E C H N O L O G Y

G S 3 0 5 0 - AG S M U N I V E R S A LW I R E L E S S A L A R MC O M M U N I C A T O R

G S 3 0 5 0 - IG S M U N I V E R S A LW I R E L E S S A L A R MC O M M U N I C A T O R

A D D R E S S A B L E E X P A N S I O N

S E R I A L I N T E R F A C E

I N T R U S I O N

A M B - 3 0 0A D D R E S S A B L EP A S S I V EI N F R A R E DD E T E C T O R

A M A - 1 0 0A D D R E S S A B L EG L A S S B R E A K D E T E C T O R

A M B - 5 0 0A D D R E S S A B L EC E I L I N G - M O U N TP A S S I V E I N F R A R E DD E T E C T O R

A M B - 6 0 0A D D R E S S A B L EP E T- I M M U N EP A S S I V E I N F R A R E DD E T E C T O R

F S B - 2 1 0 S E R I E SA D D R E S S A B L E P H O T O E L E C T R I CS M O K E D E T E C T O R S

A M P - 7 0 0 / A M P - 7 0 1A M P - 7 0 1 N P / A M P - 7 0 2A M P - 7 0 4 / A M P - 7 0 4 FA D D R E S S A B L E C O N T A C T M O D U L E S

A M X - 4 0 0L O O P R E P E A T E R /I S O L A T O R M O D U L E

A M L - 7 7 0L O O PI S O L A T O RM O D U L E

A LT E R N A T EC O M M U N I C A T I O N S

T- L I N K TM

N E T W O R K A L A R M C O M M U N I C A T O R

T- L I N K TM T L 2 5 0I N T E R N E T A L A R M C O M M U N I C A T O R

2 - W I R E A D D R E S S A B L EL O O P ( S )

W L S 9 2 5 L - 4 3 3W I R E L E S S D O O R /W I N D O W C O N T A C T

W L S 9 0 4 P L - 4 3 3W I R E L E S S P A S S I V EI N F R A R E D D E T E C T O R

W L S 9 1 2 L - 4 3 3W I R E L E S SG L A S S B R E A KD E T E C T O R

W S 4 9 1 6W I R E L E S S P H O T O E L E C T R I C S M O K E D E T E C T O R

W S 4 9 3 94 - B U T T O N W I R E L E S S K E Y

P C 4 1 6 4 - 4 3 3W I R E L E S S R E C E I V E R

4 - W I R E C O M B U S

P C 4 2 0 4 C XP O W E R S U P P LY /R E L AY O U T P U T / C O M B U S R E P E A T E RM O D U L E

P C 4 1 0 8 A / P C 4 1 1 68 / 1 6 H A R D W I R E Z O N E E X P A N D E R S

L C D 4 5 0 1P R O G R A M M A B L E -M E S S A G E L C D K E Y P A D

P C 4 2 1 61 6 P R O G R A M M A B L E O U T P U T M O D U L E

W I R E L E S S E X P A N S I O N

L C D 4 5 2 1P R O G R A M M A B L EF I R E - M E S S A G EL C D K E Y P A D

P C 4 7 0 1D U A L - L I N E D I A L E R M O D U L E

P C 4 7 0 2 B PD U A L - Z O N E B E L L P A N E L

P C 4 2 0 4 C X C FC O M M E R C I A L F I R EP O W E R S U P P LY

E S C O R T TM 4 5 8 0T E L E P H O N E I N T E R F A C E& A U T O M A T I O NC O N T R O L M O D U L E

D L S 2 0 0 2 S AS Y S T E M A D M I N I S T R A T O R TM

S O F T W A R E

W I N D O W S S O F T W A R E

L O C A L / R E M O T E C O N T R O LW I T H V O I C E P R O M P T

T- R E X TM

R E Q U E S T- T O -E X I T D E T E C T O R

M U LT I P L ER E A D E RT E C H N O L O G I E S

A C C E S S C O N T R O L

F I R E A L A R M

P C 4 6 3 2 / 4 6 6 43 2 / 6 4 P O I N T & G R A P H I CA N N U N C I A T O R S

A U T O M A T I O N

P C 4 8 2 02 - R E A D E R A C C E S SC O N T R O L M O D U L E

F S A - 2 1 0 / 4 1 0 S E R I E S2 / 4 - W I R E P H O T O E L E C T R I CS M O K E D E T E C T O R S

D L S 2 0 0 2D O W N L O A D I N GS O F T W A R E

P C 4 4 0 1D A T A I N T E R F A C EM O D U L E

W L S 9 1 4 - 4 3 3W I R E L E S S P E T- I M M U N EP A S S I V E I N F R A R E DD E T E C T O R

P S 4 3 5 0 RE X T E R N A L B A T T E R Y C H A R G E R

Page 12: MAXSYS - DSC

Distributed by:For product informationwww.dsc.comProduct specifications and availability subject tochange without notice. Certain product namesmentioned herein may be trade names and/orregistered trademarks of other companies.©2006 2006•05

P/N

30

00

03

50

R0

01

Prin

ted

inC

anad

a

M A X S Y S

A M E R I C A N L I S T I N G SCategory Description Applicable Standard

APAW Police station alarm units (commercial burglary) UL365, UL1635AMCX Central station alarm units (commercial burglary) UL1610, UL1635AOTX Local alarm units (commercial burglary) UL609, UL1635NBSX Household burglar alarm units UL1023UTOU Control units and accessories UL985UOJZ Control units system (commercial fire) UL864ALVY Access control system units UL294

E U R O P E A N L I S T I N G SThis product is in conformity with EMC directive 89/336EEC, R&TTE directive 1999/5/EC and lowvoltage directive 73/23/ECC based on results using the harmonized standards: CISPR Class B,EN50130-4, TBR21, EN60950-1.

A U S T R A L I A N L I S T I N G SThe product carries the A-Tick, Australian compliance mark, indicating that it meets the minimumsafety and network integrity standards set by the ACA and can legally be connected to thetelecommunications network in Australia.

C H I N E S E L I S T I N G SCertification under MII (Network Access License) and CCC (Burglar Alarm Systems)CCC Standard: General Specifications for Burglar-Alarm Control Units GB 12663-2001 MII standards: GB/T 15279-2002,YD/T 868-1996, YD/T 968-2002, YD/T 965-1998, YD/T 993-1998

C A N A D I A N L I S T I N G SDescription Applicable Standard

Central station fire alarm system units CAN/ULC-S527Central monitoring station burglar alarm system units CAN/ULC-S302Local alarm units (commercial burglary) CAN/ULC-S303Household burglar alarm system units CAN/ULC-S310Household fire warning system units CAN/ULC-S545Access control system units UL294

L I S T I N G S