may • 25-27, 2004 2004 · communications and information technology, which should allow...
TRANSCRIPT
www.lst.ro 2004
ROMANIAN LIVE WORKING ASSOCIATION
The 7th lnternational Conference on Live Maintenance
May • 25-27, 2004 Romania JW Marriott Bucharest Grand Hotel
LWA
Organizers
ICOLIM2004 • 2
LIVE WORKING ASSOCIATION (LWA) An association of eight countries (Hungary, France, Italy, Portugal, Spain, Romania, Germany and Czech Republic) with the scope of promoting and coordinating the activities of the various member countries in accordance with national circumstances so that there are no regulation or standardization measures
taken that could impede the development and practical performance of Live Working.
LWA promotes European industrial policy with respect to national economies and market regulations particularly through exchanges of information on decisions related to important investments in order to optimise the development of LW.
LWA achieves its objects by all appropriate methods, notably it organises the periodical conference ICOLIM.
ASOCIATIA PENTRU LUCRUL SUB TENSIUNE DIN ROMANIA (ALSTR) – THE ROMANIAN LIVE WORKING ASSOCIATION
ALSTR represents the Romanian technical authority in the field of Live Maintenance, in respect of the electrical installations within the Romanian Power System and the consultant organism of the management of TRANSELECTRICA, SMART, ELECTRICA and other companies interested in this field.
C.N. TRANSELECTRICA S.A.
The Romanian Power Grid Company “TRANSELECTRICA” SA is the Transmission and System Operator (TSO) of the entire Romanian Power System. It is a joint stock, state-owned company, with eight branches,
with a high share of public assets and a high degree of autonomy and functions according to transmissions and systems operator licenses and the transmission grid code.
S.C. ELECTRICA S.A.
SC Electrica SA is a state-owned company.
Its core activity is electricity distribution, supply and provision of the infrastructure of communications and information technology, which should allow high-quality management on the liberalized market, taking into account the competition in the field. The company’s main activities are the operation and development of the distribution system, communications and information technology, as well as the activities related to the supply of electricity to their customers.
LWA
S.C. SMART S.A.
The Commercial Company for Power Transmission Grid Maintenance Services – „SMART” SA emerged in compliance with Romanian laws in force and is operating according to its own statute. The main goal of SMART activity is to provide maintenance services for the power transmission grid. SMART SA provides services of maintenance, current repairs, overhauls for OHL’s and cabling, primary (0.40-750kV) and secondary power equipment, automation, protections and telecommu-nications.
www.lst.ro/lwa
www.lst.ro
www.transelectrica.ro
www.smart-sa.ro
www.electrica.ro
From The Conference Main
Welcome to ICOLIM 2004 On behalf of the ICOLIM – 2004 Organizing Committee, I would like to take this opportunity to welcome you to our 2004 Conference. It is the 7th International Conference on Live Mainte-nance. The six previous conferences took place in
• Hungary 1992
• France 1994
• Italy 1996
• Portugal 1998
• Spain 2000
• Germany 2002. It is a great honor for our country to be given the opportunity to organize a technical – scientific event of
such importance. Ever since 1979, Romania has been promoting Live Maintenance within the high voltage power grid (220-400kV), in co-operation with a partner from the former Democratic Republic of Germany. Nowadays, CN Transelectrica – the Romanian transmission and system operator and SC Electrica – the Romanian distribution operator, are the promoters of Live Maintenance within the high voltage power grid (220-400kV), respectively low voltage, medium voltage and 110kV. Furthermore, I am convinced that this conference will be a significant element in the future developing of Live Maintenance generally, and in Romania especially. The themes of this conference are centered on the following main subjects:
• Live maintenance in low, medium and high voltage fields
• Laws and regulations
• EHV networks monitoring. The technical committee of LWA together with ICOLIM 2004 Organizing Committee developed a technical
program that covers the following aspects concerning:
• Live Maintenance methods and procedures
• Economics
• Work safety
• Quality and efficiency
• Training
• Monitoring of power grid and equipments. Our exhibitors will be displaying the latest developments in this area that can help your company to work
more efficiently and in a cost effective manner. Our demonstrations will be the highlight of ICOLIM 2004. I hope that over the next three days, you will be able to take advantage of all the learning opportunities
that are at your disposal. Take some time to share ideas as well as learn what others are doing as far as Live Mainte-nance is concerned.
All the participants, exhibitors, field demonstration companies will share their strategies, ideas and vision for the future of Live Maintenance.
I hope that you will benefit from this opportunity offered with the occasion of ICOLIM 2004. Please, take some time and enjoy the Romanian tourist attractions as well.
Respectfully yours, Stelian Gal,
General Chairman of ICOLIM 2004
ICOLIM2004 • 3
Schedule At-A-Glance Conference Focus Within the scope of a technical conference specific theoretical and practical presentations will be organized, which essentially deal with the following live maintenance aspects: SECTION ITION I: Live maintenance in low-, medium- and high-voltage fields · Operational experiences · Working methods and procedures · New technologies, e.g. robotics ION II: SECTION II Laws and regulations · Economic aspects · Safety aspects · Materials, tools and protective equipment · Quality and efficiency · Recruitment, training and qualification · Requirements in a deregulated market SECTION III: SECTION III EHV networks monitoring · Isolation coordination and safety distance · Electromagnetic fields · Monitoring of electrical networks and equipments
Monday | May 24 MARRIOT HOTEL 1.00 pm - 7.00 pm • Conference Registration 7.00 pm - 9.00 pm • Welcome Reception Tuesday | May 25 MARRIOT HOTEL 7.00 am - 6.00 pm • Conference Registration 9.00 am - 10.00 am • Conference Opening 10.00 am - 10.30 am • Coffee Break 10.30 am - 6.00 pm • Indoor Exhibit Floor Open 11.30 am - 1.30 pm • Technical Papers Panel Session 1.30 pm - 3.00 am • Lunch 3.00 pm - 4.30 pm • Technical Papers Panel Session + Round Tables 4.30 pm - 5.00 pm • Coffee Break 5.00 pm - 6.30 am • Technical Papers Panel Session + Round Tables 8.00 pm - 10.00 pm • Galla Dinner Wednesday | May 26 DOMNESTI SUBSTATION 7.00 am - 4.00 pm • Conference Registration at Marriot Hotel 9.00 am - 5.00 pm • Outdoor Exhibits And Demonstrations Open 12.00 am - 1.30 pm • Buffet Luncheon at Outdoor Site • all day Indoor Exhibit Floor Open Thursday | May 27 MARRIOT HOTEL 7.00 am - 4.00 pm • Conference Registration 9.00 am - 10.30 am • Technical Papers Panel Session + Round Tables 8.00 am - 5.00 pm • Indoor Exhibit Floor Open 10.30 am - 11.00 am • Coffee Break 11.00 am - 1.00 pm • Technical Papers Panel Session + Round Tables 1.00 am - 2.30 pm • Lunch 2.30 pm - 4.00 pm • Technical Papers Panel Session + Round Tables 4.30 pm - 5.30 pm • Closing Session 7.00 pm - 10.00 pm • Conference Dinner
Table of Contents
Conference focus …………………………………….3 Schedule At-A-Clance ……………………………….3 General information …………………………… 4÷6 Special Events ………………………………………..8 Technical Program At-A-Glance ………………..10 Technical Program ………………………… 11÷16 Outdoor Exhibits & Demonstration ……………17 Indoor Exhibit & Floor Map ……………………...18
ICOLIM2004 • 4
ICOLIM2004 • 5
Registration For registration, participants incl. authors are requested to use the attached registration form and to send it to the secretariat’s ad-dress mentioned below. To enjoy the early bird registration fee and to appear on the list of participants, the registration must be received before 10.04.2004. Conference Secretariat ALSTR • ICOLIM 2004 Bld. Gh. Magheru, 33 • RO-70164, Bucharest, 1 Phone: +40 21 3035828 Fax: +40 21 3035820 E-mail: [email protected] Homepage: www.lst.ro On-site Registration Conference registration on-site opens on: Monday, May 24, 1.00 pm - 7.00 pm. and will be open: Tuesday, May 25, 7.00 am - 6.00 pm Wednesday, May 26 7.00 am - 4.00 pm Thursday, May 27 7.00 am - 4.00 pm The registration desk will be located at the entrance of the conference area. Venue JW Marriott Bucharest Grand Hotel Calea 13 Septembrie Bucharest, , 050713, Romania Phone: 40 21-4030000 Fax: 40 21-4030001
Participation Fee a) The participation fee is 500 EURO, if the payment is made until 10.04.2004 or 650 EURO, after 10.04.2004. For University members, the Organising Committee will award discounts of the participation fee, for a limited number of applicants. The request will be addressed to the E-mail: [email protected] . b) For those who submitted papers the participation fee is 300 EURO, if the payment is made until 10.04.2004 or 350 EURO, after 10.04.2004. These fees are only for the authors whose papers have been included in the ICOLIM Program. c) The participation fee for accompanying persons is 100 EURO, if the payment is made until 10.04.2004 or 120 EURO, after 10.04.2004. d) The Round Table fee is 200 EURO/hour. e) The indoor exhibition fee is 100 EURO/m2. f) The outdoor exhibition fee is 10 EURO/m2. The fuIl conference registration fee includes: • Admission to all sessions, technical pres-
entation and the exhibition • One copy of the ICOLIM 2004 proceed-
ings incl. CD-ROM • Cofee breaks • Lunch and drinks • The Welcome Reception • Conference Dinner • Gala Dinner The registration fee for the accompanying person covers the Welcome Reception, the Conference Dinner and Gala Dinner. Payment Payment for registration must be made in EURO (€). The conference fee has to be fully paid in advance. On-site registrations have to be paid by cash in Euros. Cancellation Cancellations by written notice before May 10, 2004, may receive a full reimbursement of paid registration fees with deduction of EURO 50 for handling costs. After this date no refund will be granted. Proceed-ings and CD-ROM will be sent to the no-show regis-trants after the conference.
General Information
ICOLIM2004 • 6
Proceedings Each participant will receive a printed copy of the proceedings incl. CD-ROM on-site. Additional copies of the proceedings will be on sale during and after the conference. Badges A badge will be issued to each participant, which gives access to the conference sessions. lt shall be worn throughout the conference period and during all social events. The badges, the list of participants and the proceedings will be available at the registration desk. Conference languages The languages during the conference are English and French (dependent on the number of participants lan-guage services for German or Spanish will be offered). Technical presentations On the third day of the conference, Wednesday, May 26, technical presentations have been organised. A bus shuttle service is available from the JW Marriott Bucha-rest Grand Hotel to the switchgear plant Domnesti, every hour, from 8:00 am to 4:00 pm. A list of scheduled activities and presenting companies will be distributet on-site. Exhibition The indoor exhibition will take place in the Large Hall of the JW Marriott Bucharest Grand Hotel. Opening hours Tuesday, May 25, 2004 from 10:30 am to 6 pm hrs and on Thursday, May 27, 2004 from 8:00 am to 5 pm hrs. Accommodation Accommodation will be available in the conference hotel and other hotels of various categories close to the venue. You may place your reservation with the attached reservation form or downloaded from the home page: www.lst.ro.
The keyword for the reservation is “ICOLIM 2004’. A deposit of 1 night rate will be required by the hotel agency. Hotel reservations shall be made well in advance but not later than May 1, 2004 to ensure that rooms will be available in the required category. The hotel registration form included in this booklet shall be mailed or faxed directly to the hotel agency. Car parking There is a limited car-park at the JW Marriott Bucharest Grand Hotel. Liability/ lnsurance The organiser cannot assume responsibility whatsoever for damage or injury to persons or property during the conference. lt is recommended to arrange for your own travel and health insurance. Formalities / Visa Some foreign nationais may require entry visas to Romania. Please check this matter right in time with the Romanian Embassy or Romanian Consulate in your country. They will help you to complete the required entry formalities. Weather Moderate temperatures may be expected in May. But occasicnal rain is not uncommon during this period. Therefore a jacket or sweater and an umbrella is recommended especially for the evenings.
General Information
ICOLIM2004 • 7
General Information
Messages for Conference participants Messages destinated to ICOLIM 2004 participants, rnay be sent from Monday, May 24, 2004 to Thursday, May 27, 2004, from 8:00 am to 6:00 pm hrs to the conference office: ALSTR ICOLIM 2004 Bld. Gh. Magheru, 33 RO-70164, Bucharest, 1 Phone: +40-21-3035828 Fax: +40-21-3035820 E-mail: [email protected] Electricity/Phone Patch The mains power supply is 220 VAC, 50 Hz. Authors presenting from their laptop are kindly asked to have suitable connectors available for the mains and RJ-11 plugs to ccnnect the phone grid. Emergency Services Police: call 955 , 9544, 956, 2102525 Arnbulance: 961, 973, 9761 or 4502855
Social program Welcome reception at JW Marriott Bucharest Grand Hotel. Monday, May 24, 2004 7.00 pm - 9.00 pm hrs for all registered participants. This evert provides an opporturtunity to meet with other ICOLIM 2004 participants and exhibitors. Snacks ard beverages will be served. Gala Dinner Tuesday , May 25, 2004, from 8.00 pm - 10.00 pm hrs, at the Palace of Parliament. Conference Dinner Thursday , May 27, 2004, from 7.00 pm - 10.00 pm hrs, at JW Marriott Bucharest Grand Hotel. More information for the social events will be distributed with the conference material distributed on-site.
lmportant Addresses
Pre-registration ICOLIM 2004 Secretariat ALSTR ICOLIM 2004
Bld. Gh. Magheru, 33 RO-70164, Bucharest, 1
Phone: +40 21 3035828 Fax: +40 21 3035820
E-mail: [email protected] Homepage: www.lst.ro
Conference Office on-site
JW Marriott Bucharest Grand Hotel Calea 13 Septembrie
Bucharest, , 050713, Romania Phone: 40 21-4030000
Fax: 40 21-4030001
ICOLIM2004 • 8
Technical Committee Germany Jörg Adamus Spain Martin Portillo Belinchón France Bruno Morin Hungary Gábor Kovács Italy Giorgio De Dona Portugal Ascensao Gaspar Czech Jaromir Stankovsky Romania Ioan Diaconu
Steering Committee Germany Jens Jühling Spain Angel Pėrez Herranz France Bernard Arnaud Hungary Lajos Gelencser Italy Mario Iulita Portugal Rui Bravo Czech Republic Stanislav Motejzik Romania Stelian Gal
General chairman Dr. ing. Stelian Gal
Technical chairman Ing. Ioan Diaconu
LWA—Live Working Association
Honour Committee
Dan Ioan Popescu Minister of Economy and Commerce
Iulian Iancu
Secretary of State
Gheorghe Indre Ministry of Economy and Commerce
Energy Division General Manager
Jean Constantinescu
Transelectrica S.A. General Manager
Silviu Lucian Boghiu
S.C. Electrica General Manager
Dan Gheorghiu
ISPE General Manager
ICOLIM2004 • 6 ICOLIM2004 • 9
Special Events
JW Marriott Bucharest Grand Hotel Calea 13 Septembrie Phone: 40 21-4030000 Monday , May 24, 2004 7.00 pm - 9.00 pm
Welcome Reception
JW Marriott Bucharest Grand Hotel Thursday, May 27, 2004 7.00 pm - 10.00 pm
Conference Dinner
Palace of Parliament Tuesday , May 25, 2004 8.00 pm - 10.00 pm
Galla Dinner
ICOLIM2004 • 10
Technical Program At A Glance
Time Room GB D Section I
Room GB C Section II
11:30—13:30 Session S1.1. Session S2.1. Session S3.1.
15:00—16:30 Session S1.2. Session S2.2. Session S3.2.
17:00—18:30 Session S1.3. Session S2.3. Session S3.3.
Room GB A Section III
25.05.2004
Time Room GB D Section I
Room GB C Section II
09:00—10:30 Session S1.4. Session S2.4. Session S3.4.
11:00—13:00 Session S1.5. Session S2.5. Session S3.5.
14:30—16:30 Session S1.6. Session S2.6. Session S3.6.
Room GB A Section III
27.05.2004
25.05.2004 9.00 am - 10.00 am Conference Opening
GB D
GB C
GB A
JW Marriott Bucharest Grand Hotel
ICOLIM2004 • 11
ICOLIM 2004 SECTION I (Room GB D, Tuesday May, 25)
Live maintenance in low, medium and high voltage field
Time No. Title Authors Company Country
11:30- 12:00
1 A study on the Development of an Op-erator-assisted Distribution Work Robot
Tomoyuki Iwashita Kentaro Kawamura Moriyuki Nakashima
Seiki Noda
Kyusyu Electric Power Co Inc.
Japan
12:00- 12:30
2 Mobile bypass system for Medium Voltage Switch-Disconnectors
Dr. Peter Hasse Gerhard Rotter
DEHN + SOEHNE GmbH + CO. KG
Germany
12:30- 13:00
3 Live Working in Medium Voltage Indoor Installations in Germany
Dr. Ralph Brocke Dr. Peter Hasse Gerhard Rotter
DEHN + SOEHNE GmbH + CO. KG
Germany
13:00- 13:30
4 Operational Experiences-Live Working in Medium Voltage Field in Czech Republic
Stanislav Motejzik Jaromir Stankovsky
Zapadoceska ener-getika a.s (CEZ)
Czech Republic
S1.1. Chairmen: Jorg Adamus • Peter Anders
15:00- 15:30
5 RWE Energy steps into medium voltage live working
Peter Anders RWE Net AG Germany
15:30- 16:00
6 Conductor replacement on 15 kV distribution line by means of hot-stick working method (Live-Line Works)
Antonio Pons Miguel A. Fernandez
GESA-ENDESA Cobra Instalaciones
y Servicios SA Spain
16:00-16:30
7 Design Considerations for Aerial Devices with Insulated boom for live working M.Gamba REMA Engineering Italy
S1.2. Chairmen: Giorgio De Donna • Rėmi Dubail
17:00-17:30
8 Replacement of long rod tension insula-tors string on the anchor support and angle support on 110 kV overhead lines.
Ryszard Michniewski Zbigniew Konieczny
ZETSA TORUN Poland
17:30-18:00
9 Working under induced voltage condi-tions at installation of EHV cable sys-tems
Dr.ing. Gero Schroder ABB Energiekabel
GmbH Germany
18:00-18:30
10 A few considerations on the pipelines’ safety nearby the electric transmission lines
Robert Pecsi UTCB
Fac. de Instalatii Romania
S1.3. Chairmen: Anca Popescu • Jaromir Stankovsky
Technical Program
S1.6. Chairmen: Stanislav Motejzik • Nicolae Tulici
S1.5. Chairmen: Mario Iulita • Giorgio De Dona
ICOLIM2004 • 12
ICOLIM 2004 SECTION I (room GB D, Thursday, May 27) Live maintenance in low, medium and high voltage field
Time No Title Authors Company Country
09:00- 09:20
11 Substitution with tension and passage of current of a diverter switch of 500 kV, including insulators support
Luis Neira Guillermo Lockhart
Carlos Curbelo
CTM Salto Grande Argentina
UTE Uruguay UTE Uruguay
Argentina Uruguay
09:20- 09:40
12 A new device for supporting linemen during live activities on conductor
Mario Iulita Doriano Bosonetto
Terna Italy
09:40- 10:00
13 Re-establishing the Live Working Program on 345 kV Structures at Northeast Utilities
K. Bowes F. Hayward George Gela
Northeast Utilities System
Northeast Utilities EPRIsolutions. Inc
USA
10:00- 10:30
14 Micro Master—the transformers time life extending solution
Anca Panta ADREM Invest Romania
S1.4. Chairmen: Gabor Kovacs • Constantin Matea
11:00- 11:25
15 RED ELECTRICA de Espana: safety and advanced achieved for live line works in overhead transmission lines
Luis Fernando Ferrer Moreno Rafel Garcia Fernandez
RED ELECTRICA Spain
11:25- 11:50
16 Experimental LW technology for multiple tension insulators replacement on 400 kV Lines
Constantin Munteanu SC ICEMENERG SA Romania
11:50-12:15
17 Live washing Marcelin Vaillant EDF SERECT France
12:15-12:40
18 Modern Techniques of inspecting the transmission overhead lines
Stelian Gal Fezi Cristian Peter Vitner
CN Transelectrica-STSibiu
EN-Centrum
Romania Romania
Czech Rep.
12:40-13:00
19 On the Economic and Strategic Impact of Robotics Applied to Transmission Line Maintenance
Serge Montambault Hydro-Quebec (IREQ) Canada
14:30- 14:50
20 Fall Protection and Rescue for Work on Transmission and Transformation Equipment
Jean Pierre Martin Helio Machado
North Safety Products
Canada Brasil
14:50- 15:10
21 Improvement of ergonomics during live work in raining conditions
Guy Riquel Stėphane Bilard
EDF R & D EDF SERECT
France
15:10- 15:30
22
Practical concept for Live-Line Mainte-nance on EGAT’s 500 kV Compact Line: Application of Portable Protective Air Gaps (PPAG)
Vichian Niamsorn Kitti Petchsanthad
George Gela
EGAT EPRIww
EPRI soluttions
Thailand Thailand
USA
15:30- 15:50
23 Data collection methodology applied to electrical infrastructures Paulo Rodrigues ESTEREOFOTO Portugal
Technical Program
S2.3. Chairmen: Angel Perez Herranz • Claire Vincent
ICOLIM2004 • 13
S2.1. Chairmen: Bruno Morin • Florin Bălaşiu
ICOLIM 2004 SECTION II (Room GB C, Tuesday, May, 25) Laws and regulations
17:00- 17:20
10 Normal scheme deviation (ASN) enforced by operation withdrawal, a possible argument for under-voltage work (LST) in Transelectrica
Ilie Ardelean Nastasia Vornic Stefan Kilyeni
ST Timisoara ST Timisoara
U.P. Timisoara Romania
17:20- 17:40
11 Thermal Performance of 30.5 and 106.7 cm Long Electric Arcs
Donald A. Gillies Nestor Kolcio
Ernest A. Jones Jim Stillwagon
Gillies & Associates 2KConsultants Inc.
E.A. Jones Associates Gary Guard, Inc
USA
17:40- 18:00
12 Development of an Industry Guide for Live Work on AC Transmission Lines
T. Verdecchio J. Tomaseski
G. Gela, K. Buchholz T. Buonincontri J. Christensen
D. Dodds, E. Hunt C. Kelly, N.Kolcio
S. Thiese
PSE&G, IBEW EPRIsolutions
PG&E, ConEdison PAR Electrical Contractors
Quanta Energized Services
WAPA, EEI 2K Consultant
L.E. Meyer
USA
S2.2. Chairmen: Jens Jühling • George Gela
15:00- 15:30
7 Accidents during Live line Working-Isolated Events or Common Causality?
Gary Donald David Borrie
Compass Power Solutions
U.K.
15:30- 16:00
8 Live maintenance regulation evolution in ENDESA-Operation regulation
Luis Alejandro Villanueva Guerrero
Pedro Javier Zarco Perinan
ENDESA Dis-tribucion Electrica
Spain
16:00- 16:30
9 Normative and Training of Live Working in EDENOR SA
Mario Ramos Ricardo Casas
Edenor SA Argen-
tina
Technical Program
Time No. Title Authors Company Country
11:30- 11:50
1 Operational organization for live working in RTE Jolanta Ricard
Bruno Vuilleumier Guy Delmas
RTE France
11:50- 12:10
2 Protective suits made of arc-resistant fabrics Dr. Eberhard Muller-
Steineck G.Schumer GmbH & Co.,Schuttorf
Germany
12:10- 12:30
3 Multimedia technologies and the virtual reality for the training of the ”Persons involved in Live Working”
De Dona Giorgio Grosso Gianfranco Lomonte Giancarlo
Tomasella Gianmario
Terna Italy
12:30- 12:50
4 Design influence of the insulating stick over their lifespan
Sylvestre Arberet Christian Atlani
Catu SA France
12:50- 13:10
5 A comparison of Strict Procedural and Limited Rule Based Systems for Live Line Working
Gary Donald Gareth Reid
Compass Power Solutions
U.K.
13:10- 13:30
6 Continuous assessment or repeated structured training-maintaining the skill level
Gary Donald Gareth Reid
Compass Power Solutions
U.K.
ICOLIM2004 • 14
Time No Title Authors Company Country
09:00- 09:30
13 Detection of internal faults
Guy Riquel Eric Spangenberg
Jean-François Labansat
EDF Recherche et Developpement
EDF SERECT
France
09:30- 10:00
14 New German Accident Prevention Rule for Live Working
Dr.ing. Jens Juhling Institute for the Investigation of
Electrical Accidents Germany
10:00- 10:30
15 Personal protective Equipment (PPE) for live work
Guy Riquel Arnaud Gayrard
Nicolas Oury
EDF Recherche et Developpement EDF SERECT
France
S2.4. Chairmen: Bernard Arnaud • Jacques Lalot
ICOLIM 2004 SECTION II (Room GB C, Thursday, May, 27)
Laws and regulations
11:00- 11:25
16 Professionalism in live working Jean Francois
Mougenet EDF SERECT France
11:25- 11:50
17 Studies of different methods for testing of clothing for protection against the thermal hazards of an electric arc
Dr.ing. Holger Schau Dr.ing.Dirk Borneburg
RWE Eurotest GmbH Technische Universitat
Ilmenau Germany
11:50-12:15
18 Necessity and opportunity of using live mainte-nance at medium voltage overhead lines
Viorel Dan Ileana Rus Iacob Blagu
Electrica SISEE Banat SISEE Banat AISEE Sibiu
Romania
12:15-12:40
19 The Extension Of Live Maintenance Technologies Applicable Within The Romanian Power Transmission Grid
Ioan Diaconu Claude Chodot
Stelian Gal Traian Fagarasan
C. Munteanu
SC SMART SA EDF-SERECT
CN Transelectrica -STS SC SMART-Sibiu
ICEMENERG
Romania France
Romania Romania Romania
12:40-13:00
20
Considerations on the impact of the Romanian electricity sector restructuring on the mainte-nance organising and the need to promote live works to OHL
Gabriel Romascu Christiana Barbulescu Anca-Maria Diaconu
Nicolae Tulici Lacramioara Jurca
Transelectrica Transelectrica-ST Sibiu
Romania
14:30- 14:55
21 Minimum requirements for LW trainees Jorg Adamus
Mathias Diedrich VATENFALL EUROPE Germany
14:55- 15:20
22 Impact of the LW activities on the service quality indices
Gabor Kovacs DEDASZ Hungary
S2.5. Chairmen: Ascensao Gaspar • Ileană Bâran
S2.6. Chairmen: Rui Bravo • Ciprian Diaconu
Technical Program
S3.3. Chairmen: Stelian Gal • Ilie Ardelean
S3.2. Chairmen: Ioan Diaconu • George Florea
ICOLIM2004 • 15
S3.1. Chairmen: Gleb Drăgan • Golovanov Nicolae
17:00- 17:20
10 Live working. A method of calculation of minimum approach distances. Comparison between the new and old edition of IEC 61472 Standard.
De Dona Giorgio Valagussa Claudio
Terna (enel) Cesi
Italy
17:20- 17:40
11 Interconnection the Supervisory Control and Data Acquisition of Power Systems (SCADA)
Sorin Niculescu Transelectrica-ST
Craiova Romania
17:40- 18:00
12
Why not to use live– line techniques for ACSR conduc-tor joints end of life prediction? Romanian theoretical assumptions, actual practices and future management are on this way!
George Florea Stelian Gal
E. Mateescu Constantin Munteanu
Nicolae Tulici Lacramioara Jurca
TEHNOROB SA Transelectrica-ST Sibiu
ISPE ICEMENERG SA
Transelectrica-ST Sibiu Transelectrica-ST Sibiu
Romania
18:00- 18:30
13 Condition assessment of composite insulators through non-destructive investigation
Constantin Munteanu SC ICEMENERG SA Romania
Time No. Title Authors Company Country
11:30- 11:50
1 Discharge development and spark-over in an air gap containing an object at floating potential
N.L.Allen S.Chotigo
Department of electri-cal engineering&
electronics U.K.
11:50- 12:10
2 Tests In High Voltage Laboratory About The Insulat-ing Structure Performances
Viorel Titihazan Adrian Buta
Mariana Titihazan Flavius Dan Şurianu
Adrian Pana Nicolae Chiosa Ilie Ardelean
Nicolae Pantazi Dragan Nesin Gheorghe Rus Traian Tudor
Univ. Politeh. Timisoara Univ. Politeh. Timisoara Univ. Politeh. Timisoara Univ. Politeh. Timisoara Univ. Politeh. Timisoara Transelectrica—STT.
ST Timisoara ST Timisoara ST Timisoara ST Timisoara ST Timisoara
Romania
12:10- 12:30
3 Automatic calculation of ground protection installation for outdoor transformers
Silvia-Maria Diga Cristian Bratu
Universitatea Craiova Romania
12:30- 12:50
4 Pricipial Errors Of The Ground Electrical Field Measur-ing With Spherical Dipole Related To The Overhead Lines
Dr.ing. Gheorghe Magureanu
UPB Facultatea de
Energetica Romania
12:50- 13:10
5 Electrogeometric theorie or electrostatic theorie? (Determination of the impact point of the lightning with the ground)
Prof.univ.Ovidiu Centea
Facultatea de Instalatii
Romania
13:10- 13:30
6 Safety distances for live working in Spain, based on the European standards
Angel Perez Herranz UNESA Spain
ICOLIM 2004 SECTION III (Room GB A, Tuesday, May 25) EHV networks monitoring
15:00- 15:30
7 Gas insulated bushings with voltage monitoring device P. Bertolotto M. Sehovac P. Guazetti
Passoni&Villa Italy
15:30- 16:00
8 Partial Discharge Monitoring and Locating in Power Transformers, using Acoustic Emission Method
Andrei Marinescu
ICMET Craiova Romania
16:00- 16:30
9 Equipment for HV capacitor-type bushings (DPD) moni-toring
Andrei Marinescu Dorel Nedelcut Dumitru Sacer-
dotianu Ion Patru
Ion Purcaru
ICMET Craiova ICMET Craiova ICMET Craiova ICMET Craiova SC VIG Craiova
Romania
Technical Program
Time No. Title Authors Company Country
09:00- 09:30
14 Electromagnetic coupling phenomena of overhead power lines in low and high frequency
Marilena Ungureanu Codruta Roman
Politehnica University of Bucharest
Romania
09:30- 10:00
15 Measurement of radio interference voltages due to insulators sets and other line equipment
Sorin Coatu; Marian Costea
D.Rucinschi V.Cristea T.Leonida
Politehnica University of
Bucharest TICEM
Romania
10:00- 10:30
16 Response of MV insulation to standard and non-standard lightning impulses
Ileana Baran Marian Costea
Sorin Coatu
Politehnica University of
Bucharest Romania
ICOLIM2004 • 16
Technical Program
S3.4. Chairmen: Lajos Gelencser • Goia Laurenţiu
ICOLIM 2004 SECTION III (Room GB A, Thursday May, 27) EHV networks monitoring
11:00- 11:30
17 Quality of energy: New capacitor voltage trans-formers for measurement of frequencies large band
Pierino Bertolotto R. Ottoboni
Passoni & Villa Italy
11:30- 12:00
18 An Analysis of Calculation Methods regarding the Influence of Corona Impulse Discharge on Traveling Process of Voltage Surges
Gleb Dragan George A. Florea
TEHNOROB SA Romanian Academy
Romania
12:00-12:30
19 Active Power Losses Analysis in the case of Alternative Voltage Corona Discharge on the Similitude Theory Basis
Gleb Dragan M. Popescu
Romanian Academy
Romania
14:30- 14:50
20 An Accurate Model of Induced Voltage Impulse Traveling on Distribution Electric Lines with Corona Discharge and Skin Effect
George A. Florea Gleb Dragan
Romanian Academy TEHNOROB SA
Romania
14:50- 15:10
21 Measurement of ground connection of extended electrical substations
M.L. Goia University of
Oradea Romania
S3.5. Chairmen: Martin Portillo • Guy Riquel
S3.6. Chairmen: Coatu Sorin • Haţegan Ioan
Outdoor Exhibition
Demonstration
In a specially prepared substation near Bucharest several techniques for various voltage levels will be shown. (Domnesti substation)
ICOLIM2004 • 17
Sponsors
gold gold
bronze
www.catuelec.com
www.hubbellpowersystems.com
www.eximprod.ro
www.abb.com
www.areva.com www.saem.ro
www.elm.ro www.romind.ro www.inpec.com
www.siemens.com
www.romelectro.ro
bronze