McDonald’s Heated Landing Zone
The HLZ is designed to hold wrapped sandwiches while the meal order is completed
Five screws on the bottom of the unit secure the controllertower.
Nuts holding theair tower diffuserin place should beloosened, not removedwhen dismantling theunit.
The sealant on the seam of the heater plate must becut prior to prying the plate off of its adhesive backing.Remove the plate when the unit is hot; the adhesive will be more pliable.
Air RTD
Air Thermocouple
Relays
Fuses
Blower Assembly
Air Heater
Check temp. of heater plate/ adjust setpoint
Check temp. of air heater/ adjust setpoint
ON/OFFAdjust setpoint
Programmingswitch
The setpoint for the plate and the air heater can be changed:
• With the unit off, press the Check button and then buttonsmarked 1,2,3,3 in that sequence.
• SET will be displayed.• Press 1 to adjust heater plate; press 4 to adjust air temp.• Use UP (2) and DOWN (3) arrow keys to adjust setpoint.
• Press Check to lock in changes.
The reliability of the HLZ’s temperature readouts can be checked. Test ports are positioned on the unit’s front panel, which allow independent measurement of the heater plate and air heater’s temperature. A variance of ± 50F between readout and meter is acceptable.
0
12V
LOAD
COM 208/240V
FUSEBLOCK
POWERCORD
WHT BLK GRN/Y
240V OPTION(CAP UNUSED WIREW/MALE PUSH-ON)
PLATE HEATER
AIR HEATER
GRN
WH
TBLK
RED BLOWER
TOPPLATE THERMOCOUPLE (TYPE K)
BOTTOM
RED
WHT
BLK
AIR HEATRELAY
PLATERELAY
HYPOTTEST POINT
+ +
LATCHRELAY186
42 0
AIR THERMOCOUPLE (TYPE K)
COMPUTER
TEST RED WIRENEGATIVEPLUGS
7 82 91 1243 65 1411 13 1510
RED
WHT
BRNPLATERTD
AIR RTD
208V OPTION
HLZ Wiring Diagram