mcdonald’s heated landing zone the hlz is designed to hold wrapped sandwiches while the meal order...

13
McDonald’s Heated Landing Zone The HLZ is designed to hold wrapped sandwiches while the meal order is completed

Upload: stephany-harrington

Post on 15-Jan-2016

217 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: McDonald’s Heated Landing Zone The HLZ is designed to hold wrapped sandwiches while the meal order is completed

McDonald’s Heated Landing Zone

The HLZ is designed to hold wrapped sandwiches while the meal order is completed

Page 2: McDonald’s Heated Landing Zone The HLZ is designed to hold wrapped sandwiches while the meal order is completed

Five screws on the bottom of the unit secure the controllertower.

Page 3: McDonald’s Heated Landing Zone The HLZ is designed to hold wrapped sandwiches while the meal order is completed

Nuts holding theair tower diffuserin place should beloosened, not removedwhen dismantling theunit.

Page 4: McDonald’s Heated Landing Zone The HLZ is designed to hold wrapped sandwiches while the meal order is completed

The sealant on the seam of the heater plate must becut prior to prying the plate off of its adhesive backing.Remove the plate when the unit is hot; the adhesive will be more pliable.

Page 5: McDonald’s Heated Landing Zone The HLZ is designed to hold wrapped sandwiches while the meal order is completed

Air RTD

Air Thermocouple

Relays

Fuses

Page 6: McDonald’s Heated Landing Zone The HLZ is designed to hold wrapped sandwiches while the meal order is completed

Blower Assembly

Page 7: McDonald’s Heated Landing Zone The HLZ is designed to hold wrapped sandwiches while the meal order is completed

Air Heater

Page 8: McDonald’s Heated Landing Zone The HLZ is designed to hold wrapped sandwiches while the meal order is completed

Check temp. of heater plate/ adjust setpoint

Check temp. of air heater/ adjust setpoint

ON/OFFAdjust setpoint

Programmingswitch

Page 9: McDonald’s Heated Landing Zone The HLZ is designed to hold wrapped sandwiches while the meal order is completed

The setpoint for the plate and the air heater can be changed:

• With the unit off, press the Check button and then buttonsmarked 1,2,3,3 in that sequence.

Page 10: McDonald’s Heated Landing Zone The HLZ is designed to hold wrapped sandwiches while the meal order is completed

• SET will be displayed.• Press 1 to adjust heater plate; press 4 to adjust air temp.• Use UP (2) and DOWN (3) arrow keys to adjust setpoint.

Page 11: McDonald’s Heated Landing Zone The HLZ is designed to hold wrapped sandwiches while the meal order is completed

• Press Check to lock in changes.

Page 12: McDonald’s Heated Landing Zone The HLZ is designed to hold wrapped sandwiches while the meal order is completed

The reliability of the HLZ’s temperature readouts can be checked. Test ports are positioned on the unit’s front panel, which allow independent measurement of the heater plate and air heater’s temperature. A variance of ± 50F between readout and meter is acceptable.

Page 13: McDonald’s Heated Landing Zone The HLZ is designed to hold wrapped sandwiches while the meal order is completed

0

12V

LOAD

COM 208/240V

FUSEBLOCK

POWERCORD

WHT BLK GRN/Y

240V OPTION(CAP UNUSED WIREW/MALE PUSH-ON)

PLATE HEATER

AIR HEATER

GRN

WH

TBLK

RED BLOWER

TOPPLATE THERMOCOUPLE (TYPE K)

BOTTOM

RED

WHT

BLK

AIR HEATRELAY

PLATERELAY

HYPOTTEST POINT

+ +

LATCHRELAY186

42 0

AIR THERMOCOUPLE (TYPE K)

COMPUTER

TEST RED WIRENEGATIVEPLUGS

7 82 91 1243 65 1411 13 1510

RED

WHT

BRNPLATERTD

AIR RTD

208V OPTION

HLZ Wiring Diagram