mcguire stoptite a install 3-2018 · th is pr in tis th e pr op erty of sys te ms , inc .a nd ep re...
TRANSCRIPT
![Page 1: McGuire StopTite A Install 3-2018 · Th is pr in tis th e pr op erty of Sys te ms , Inc .a nd ep re se nts pro pr ie ta ry ar tic le n hic h Sy st em s,In c. re ta in s nya nd all](https://reader034.vdocument.in/reader034/viewer/2022042204/5ea554a8cdece936fa589a15/html5/thumbnails/1.jpg)
Concrete Dock Face (Standard installation)
Low Pit Floor (Distance from pit floor to drive under 24”)
Driveway Mount (Recommended when dock face is unsuitable for PowerStop Mounting)
Cantilevered Dock (For bumper projection >4” or cantilevered dock or Edge-of-Dock leveler)
TOLERANCES(UNLESS OTHERWISE NOTED)
FRACTIONAL: 1/32"DECIMAL: .00 = .01"
.000 = .005"
ANGULAR: 1
DRAWN BY CHECKED BY
DRAWING NO.
DATEBDK 12/1/2017
S Y S T E M S, I N C.L o a d i n g D o c k E q u i p m e n t
P O W E R A M P M C G U I R E
D L M
This print is the property of Systems, Inc. and represents a proprietary article in which Systems, Inc. retains any and all patent and other rights, including exclusive rights of use and/or manufacture and/or sale. Possession of this print does not convey any permission to reproduce, print or manufacture the article or articles shown therein, such permission to be granted only by written authorization signed by an officer or other authorized agent of Systems,Inc. thereof.
MATERIAL STOCK NO.
INSTALLATIONOVERVIEW VIEW 1
OptionalEmbed Plate
27”
18”
TOLERANCES(UNLESS OTHERWISE NOTED)
FRACTIONAL: 1/32"DECIMAL: .00 = .01"
.000 = .005"
ANGULAR: 1
DRAWN BY CHECKED BY
DRAWING NO.
DATEBDK 12/1/2017
S Y S T E M S, I N C.L o a d i n g D o c k E q u i p m e n t
P O W E R A M P M C G U I R E
D L M
This print is the property of Systems, Inc. and represents a proprietary article in which Systems, Inc. retains any and all patent and other rights, including exclusive rights of use and/or manufacture and/or sale. Possession of this print does not convey any permission to reproduce, print or manufacture the article or articles shown therein, such permission to be granted only by written authorization signed by an officer or other authorized agent of Systems,Inc. thereof.
MATERIAL STOCK NO.
INSTALLATIONOVERVIEW VIEW 2
Anchor pit floor mounting plate (minimum 3/8” x 20”W x 8”D, Part #9414-0056, Figure 10) with four (4) 3/4” x 5-1/4” min. wedge anchors. Weld mounting plate to curb steel and back plate of PowerStop with a continuous 1/4” fillet weld. Anchor back plate of PowerStop to dock face with a minimum of four (4) 3/4” x 5-1/4” min. wedge anchors (Kit #2103-0003). See Figure 11.
TOLERANCES(UNLESS OTHERWISE NOTED)
FRACTIONAL: 1/32"DECIMAL: .00 = .01"
.000 = .005"
ANGULAR: 1
DRAWN BY CHECKED BY
DRAWING NO.
DATEBDK 8/11/2017
S Y S T E M S, I N C.L o a d i n g D o c k E q u i p m e n t
P O W E R A M P M C G U I R E
D L M
This print is the property of Systems, Inc. and represents a proprietary article in which Systems, Inc. retains any and all patent and other rights, including exclusive rights of use and/or manufacture and/or sale. Possession of this print does not convey any permission to reproduce, print or manufacture the article or articles shown therein, such permission to be granted only by written authorization signed by an officer or other authorized agent of Systems,Inc. thereof.
MATERIAL STOCK NO.
9415-0063 STORED
FINAL ASM - PSTOP/STOPTITE 2018
27" TALL - M
If <24”
Trim frame here
Note:Trim or cut leveler front frame member as shown in Figure 12 when necessary to allow for pit floor mounting plate.
S Y S T E M S, I N C.L o a d i n g D o c k E q u i p m e n t
P O W E R A M P M C G U I R E
D L M
MATERIAL STOCK NO.
8” minimum
48” minimum
48” minimum
Driveway mount requires attachment to a concrete drive greater than 8” thick. For asphalt drive, pour 48”x48”x8” (min. ) concrete pad and include six (6) 3/4” dowels into foundation wall. Then proceed with adhesive anchors or weld plate embed.
Adhesive Anchors Method (Kit #9414-0058)At rear of StopTite, drill 1-1/8” dia. x 7” deep holes and install two (2) 1” dia. adhesive anchors. At front of PowerStop, install two (2) 3/4” dia. x 5-1/4” min. wedge anchors.
BILL OF MATERIALSIZEDESCRIPTIONPART NO.QTYITEM
1/2 X 16 X 27BAR7952-0215113/8 X 2-1/2 X 16BAR7952-0216221-7/8 OD X 1-1/8 ID X 5-3/4TUBE - LIP HINGE9512-114643
TOLERANCES(UNLESS OTHERWISE NOTED)
FRACTIONAL: 1/32"DECIMAL: .00 = .01"
.000 = .005"
ANGULAR: 1
MATERIAL
DRAWN BY CHECKED BY
DRAWING NO.BDK
7953-0195
IMBED WELDMENT - POWERSTOP 2018L o a d i n g D o c k E q u i p m e n t
This print is the property of Systems, Inc. and represents a proprietary article in which Systems, Inc. retains any and all patent and other rights, including exclusive rights of use and/or manufacture and/ornot convey any permission to reproduce, print or manufacture t he article or articles shown therein, such permission to be granted only by written authorization signed by an officer or other authorized agent of Systems, Inc. thereof.
DRIVEWAY - MOUNTED
2 1/21 1/4
4 4
27
1 1/2 1 1/2
16
2 1/21 1/4
3 1/83 1/89/16 9/16
1
3
2
.25 in
.25 in4X
- 17-077 11/15/2017 RELEASED FOR PRODUCTION
BILL OF MATERIALSIZEDESCRIPTIONPART NO.QTYITEM
1/2 X 16 X 27BAR7952-0215113/8 X 2-1/2 X 16BAR7952-0216221-7/8 OD X 1-1/8 ID X 5-3/4TUBE - LIP HINGE9512-114643
TOLERANCES(UNLESS OTHERWISE NOTED)
FRACTIONAL: 1/32"DECIMAL: .00 = .01"
.000 = .005"
MATERIAL
DRAWN BY CHECKED BY
DRAWING NO.BDK
7953-0195
IMBED WELDMENT - POWERSTOP 2018L o a d i n g D o c k E q u i p m e n t
DRIVEWAY - MOUNTED
2 1/21 1/4
4 4
27
1 1/2 1 1/2
16
2 1/21 1/4
3 1/83 1/89/16 9/16
1
3
2
.25 in
.25 in4X
- 17-077 11/15/2017 RELEASED FOR PRODUCTION
16”
4” 4”
27”
1-1/2”1-1/2”
TOLERANCES(UNLESS OTHERWISE NOTED)
FRACTIONAL: 1/32"DECIMAL: .00 = .01"
.000 = .005"
ANGULAR: 1
DRAWN BY CHECKED BY
DRAWING NO.
DATEBDK 8/11/2017
S Y S T E M S, I N C.L o a d i n g D o c k E q u i p m e n t
P O W E R A M P M C G U I R E
D L M
This print is the property of Systems, Inc. and represents a proprietary article in which Systems, Inc. retains any and all patent and other rights, including exclusive rights of use and/or manufacture and/or sale. Possession of this print does not convey any permission to reproduce, print or manufacture the article or articles shown therein, such permission to be granted only by written authorization signed by an officer or other authorized agent of Systems,Inc. thereof.
MATERIAL STOCK NO.
9415-0063 STORED
FINAL ASM - PSTOP/STOPTITE 2018
27" TALL - M
Drive Embed Method (Part #7953-0195)Weld-on:Properly locate and level the drive embed weld plate in the drive approach. Observe cantilever conditions (page 14) for proper positioning. Weld restraint to embed plate with a continuous 1/4” fillet weld.Bolt-on:Properly locate and level the drive embed weld plate in the drive approach. Observe cantilever conditions (page 13) for proper positioning. Bolt the restraint to the embed plate using 1” dia. x 6” min. bolts at the rear, and 3/4” dia. x 6” min. bolts at the front.
TOLERANCES(UNLESS OTHERWISE NOTED)
FRACTIONAL: 1/32"DECIMAL: .00 = .01"
.000 = .005"
ANGULAR: 1
DRAWN BY CHECKED BY
DRAWING NO.
DATEBDK 8/11/2017
S Y S T E M S, I N C.L o a d i n g D o c k E q u i p m e n t
P O W E R A M P M C G U I R E
D L M
This print is the property of Systems, Inc. and represents a proprietary article in which Systems, Inc. retains any and all patent and other rights, including exclusive rights of use and/or manufacture and/or sale. Possession of this print does not convey any permission to reproduce, print or manufacture the article or articles shown therein, such permission to be granted only by written authorization signed by an officer or other authorized agent of Systems,Inc. thereof.
MATERIAL STOCK NO.
9415-0063 STORED
FINAL ASM - PSTOP/STOPTITE 2018
27" TALL - M
Dim. A
Dim. B
Offset Required
Offset Formula
Dim. ABumper Projection
Dim. BCantilever
-4”= Offset
Required4” + Dim. B6” + Dim. B10” + Dim. B15” + Dim. B
Driveway MountDetermine offset, then proceed with “Driveway Mount” instructions .
Wall MountFor filler requirements from 2” to 15”, refer to the cantilever bracket table on page 33 to determine which cantilever bracket is relevant to the application in question, then anchor cantilever bracket to dock face with six (6) wedge anchors (3/4” x 5-14” min) or weld to the embed mounting plate with ten (10) 4” long, 1/4” fillet welds.
Note:To determine size offset required, take total effective bumper projection (bumper size plus any cantilever) and subtract 4”. See table and drawing to the left.
Wedge Anchors Method (Kit #2103-0003)Using back plate as a guide, drill six (6) holes for wedge anchors (3/4” x 5-14” min). Install anchors.
TOLERANCES(UNLESS OTHERWISE NOTED)
FRACTIONAL: 1/32"DECIMAL: .00 = .01"
.000 = .005"
ANGULAR: 1
DRAWN BY CHECKED BY
DRAWING NO.
DATEBDK 8/11/2017
S Y S T E M S, I N C.L o a d i n g D o c k E q u i p m e n t
P O W E R A M P M C G U I R E
D L M
This print is the property of Systems, Inc. and represents a proprietary article in which Systems, Inc. retains any and all patent and other rights, including exclusive rights of use and/or manufacture and/or sale. Possession of this print does not convey any permission to reproduce, print or manufacture the article or articles shown therein, such permission to be granted only by written authorization signed by an officer or other authorized agent of Systems,Inc. thereof.
MATERIAL STOCK NO.
9415-0063 STORED
FINAL ASM - PSTOP/STOPTITE 2018
27" TALL - M
5-1/4” minimum
Wall Embed Method (Part #7953-0119)If optional embed plate is present, weld three sides of PowerStop back plate to the embed mounting plate with ten (10) 4” long, 1/4” fillet welds.BILL OF MATERIAL
SIZEDESCRIPTIONPART NO.QTYITEM20" X 20" X 3/8"DECK PLATE7952-0147111/4 X 1 X 8CONCRETE ANCHOR7952-0009122
TOLERANCES(UNLESS OTHERWISE NOTED)
FRACTIONAL: 1/32"DECIMAL: .00 = .01"
.000 = .005"
ANGULAR: 1
MATERIAL
DRAWN BY CHECKED BY
DRAWING NO.
DATE
Steel, A36
JAH 6/28/2011
7953-0119
IMBED WLDT-PSTOP WALL MTG
P O W E R A M PM C G U I R E
D L M
L o a d i n g D o c k E q u i p m e n t
This print is the property of Systems, Inc. and represents a proprietary article in which Systems, Inc. retains any and all patent and other rights, including exclusive rights of use and/or manufacture and/or sale. Possession of this print does not convey any permission to reproduce, print or manufacture the article or articles shown therein, such permission to be granted only by written authorization signed by an offi cer or other authorized agent of Systems, Inc. thereof.
STOCK NO.20" X 20" X 3/8"
1 1/8TYP
5 TYP
3/8
20
20
20 1
2
1/4"1/4" TYP
100° 2 7 1/2 TYP
C 17-077 12/5/2017 ADDED 7952-0009 QTY 2B JAH 6/28/2011 REDRAWN FROM MODELA NMS 6/28/2011 24" TO 20"
BILL OF MATERIALDESCRIPTIONPART NO.QTYITEM
DECK PLATE7952-014711CONCRETE ANCHOR7952-0009122
TOLERANCES(UNLESS OTHERWISE NOTED)
FRACTIONAL: 1/32"DECIMAL: .00 = .01"
.000 = .005"
ANGULAR: 1
MATERIAL
DRAWN BY
Steel, A36
JAH
IMBED WLDT-PSTL o a d i n g D o c k E q u i p m e n t
This print is the property of Systems, Inc. and represents a patent and other rights, including exclusive rights of use and/or manufacture and/or sale. Possession of this print does not convey any permission to reproduce, print or manufacture granted only by written authorization signed by an offi
1 1/8TYP
5 TYP
3/8
20
20
20 1
2
1/4"1/4" TYP
100° 2 7 1/2 TYP
C 17-077 12/5/2017B JAH 6/28/2011 REDRAWN FROM MODELA NMS 6/28/2011
3/8”
20”
20”
Manual Vehicle Restraint
STOP-TITE® SERIESInstallation Overview
V e h i c l e R e s t r a i n t
![Page 2: McGuire StopTite A Install 3-2018 · Th is pr in tis th e pr op erty of Sys te ms , Inc .a nd ep re se nts pro pr ie ta ry ar tic le n hic h Sy st em s,In c. re ta in s nya nd all](https://reader034.vdocument.in/reader034/viewer/2022042204/5ea554a8cdece936fa589a15/html5/thumbnails/2.jpg)
Install Control Panel and Wiring
Optional Light Communication System
GRD51
Gre
en L
ight
Gro
und
Field wires:2, 48, 51 115 Vac ControlGround
55
Lim
it Sw
itch
(opt
ion)
Field wires:11, 46 - Proximity - 115 Vac Control47, 55 - Limit Switch Option - 115 Vac ControlGround
Wires 47 & 55 (if used)
Ground
Field wires:47, 55 - Limit Switch Option - 115 Vac ControlGround
1 50484722
L1 L2
Com
mon
Red
Ligh
t
115 Vac
1111 46
Lim
it Sw
itch
(opt
ion)
Prox
imity
Sw
itch
Prox
imity
Sw
itch
Field wires:L1, L2 - 115 Vac ControlGround
Blue
Brow
n
11 46
Junction box at face of dock
Multiconductor cable
Control assembly (by Poweramp)
Truck restraint
Ground
47 551413
Proximity switch
Limit switch (option)
Conduit must be protected from damage. Conduit & connections must be liquid tightif in area where liquid can be present
Conduit must be protected from damage. Conduit & connections must be liquid tightif in area where liquid can be present
1 GRD5150484722
L1 L2
Com
mon
Red
Ligh
t
Gre
en L
ight
Gro
und
115 Vac Field wires:
2, 48, 51 - 115 Vac ControlGround
Field wires:L1, L2 - 115 Vac ControlGround
Control assembly (by Poweramp)
Red Light
Green Light
248
51
Ground
White
Black
WhiteBlack
Field wires:2, 48, 51 - 115 Vac ControlGround
MMLPOWERSTOP - Manual Rest raint / Manual DockAlert
Operating Wand
DETAIL A
BILL OF MATERIALSIZEDESCRIPTIONPART NO.QTYITEM
BELLOWS W/ 0.688 X 17.500 STRIP0191-005811BRACKET,PSTOP M,RELEASE BAR0192-016112
1.937 DIA X 7.02 LGSPRING, COMPRESSION0941-0018130.450 DIA X 1.75 LG X 0.059 WIRE DIASPRING,EXTENSION,S.S.0941-00211410-300VDC,TURCK BI2-Q10S-RZ31XPROX SW,AC/DC,N.C.,20-250VAC0961-0614151/2, METALCONNECTOR, TUBING1431-0239163-1/4 X 14-1/2DECAL - WARNING1751-0135173-1/4 X 14-1/2DECAL - POWERAMP/POWERSTOP1751-0444186-1/2 X 2-1/4DECAL - DLM1751-02461
DECAL - MCGUIRE1751-064915/16-18 UNC X 3/4HHCS - GRADE 2 - ZINC PLATED2101-0009291/4-20 X 0.38 LGSCREW,SHSS, BLACK OXIDE2101-00332101/4-20 UNC X 7/8HHCS - GRADE 5 - ZINC PLATED2101-00848113/8-16 X 2HHCS - GRADE 2 - ZINC PLATED2101-00891121/4-20 UNCNYLON LOCK NUT2101-014381310-24 UNC X 2-1/2RHMS - SLOTTED2101-0150314#10-24 UNCNYLON LOCK NUT2101-01513151/2"E-RING2101-01898161/2-13 UNC X 1FLAT HEAD CAP SCREW2101-02282170.50 DIA X 0.375 LGSCREW,SHLDR2101-0335118STAINLESS STEELWASHER,TAG HOLE,1/2"2101-0336219#4-40 UNC X 0.875 LG PHILLIPSSCREW,RHMS2101-03372201/4" SHAFT DIA,ZINC PLATEDRING,RETAINING,EXTERNAL2101-0349221POWERSTOPJ-BOX ASSY, 2-LEAD, 26.5"2753-0004REF22
CABLE TIE 0.1x4,0.75 MAX BUNDLE3051-00013231/2 DIAPIN - PIVOT - LONG9202-00422241/2 DIAPIN - PIVOT - SHORT9202-00432257 GA - ZINC PLATEDSHROUD,PSTOP,BELLOWS MTG9411-00661260.125 X 0.688 X 17.50BAR,BELLOWS MTG,PSTOP,TOP9411-0076227
LEVER WAND,RELEASE,PSTOP-M9411-0091128PSTOP RIG SENSOR BAR PIN9411-0103129PSTOP RIG SENSOR CONNECTION9411-0104130
OUTSIDE OF HOOKPSTOP RIG SENSOR BAR9411-01051310.375 OD X 0.260 ID X 0.5 LGTBG, RIG SENSOR BAR SPACER9411-01071321-1/4 OD X 9/16 ID X 5/8TUBE9412-01612331/8 X 1 X 7.00 LGBAR,BELLOWS MTG,PSTOP,FRONT9412-02011341/8 X 1 X 23.00 LGBAR,BELLOWS MTG,PSTOP,SIDE9412-0202235
SCISSOR LIFT ASSY,PSTOP9413-00621361-1/8 OD X 11/16 ID X 2.56 LGSPACER ASSY,PSTOP-M,YLW DICH9413-0068137
PROX SWITCH ASSY, UPPER9413-0112138PSTOP LIP DEFLECTOR9413-0121139PSTOP,RELEASE LEVER ASSY9413-0122140
SINGLE STEP TALL PROFILEPOWERSTOP HOOK WELDMENT9413-0123141LOW PROFILEPOWERSTOP HOOK WELDMENT9413-01271
FINAL BASE WLDT - 27" - PSTOP9414-0083142FANTASTOCK-HCW 3-COLOR,650ROLLLABELS,4"X2" THERMAL TRANSFERXMS1-0529143A
L o a d i n g D o c k E q u i p m e n t
P O W E R A M P M C G U I R E
D L M
(26.05)
(29.31)
3
4
(27.19)
(15.50)
1237
38
18
40
2
20
17
39
33
42727 4
28
4
3
N 17-077 11/15/2017 RELEASED FOR PRODUCTIONM BDK 11/15/2017 ADDED 3051-0001 QTY 3L BDK 11/9/2017 ADDED 2101-0336 QTY 2
K BDK 10/25/2017 REMOVED 2101-0028 QTY 2 AND 9411-0102 QTY 1
55
5
5
5
5
6
5
5555
Operating wand
DETAIL A
CONNECTOR, TUBING1431-023916DECAL - WARNING1751-013517DECAL - POWERAMP/POWERSTOP1751-044418DECAL - DLM1751-02461DECAL - MCGUIRE1751-06491HHCS - GRADE 2 - ZINC PLATED2101-000929SCREW,SHSS, BLACK OXIDE2101-0033210HHCS - GRADE 5 - ZINC PLATED2101-0084811HHCS - GRADE 2 - ZINC PLATED2101-0089112NYLON LOCK NUT2101-0143813RHMS - SLOTTED2101-0150314NYLON LOCK NUT2101-0151315E-RING2101-0189816FLAT HEAD CAP SCREW2101-0228217SCREW,SHLDR2101-0335118WASHER,TAG HOLE,1/2"2101-0336219SCREW,RHMS2101-0337220RING,RETAINING,EXTERNAL2101-0349221J-BOX ASSY, 2-LEAD, 26.5"2753-0004REF22CABLE TIE 0.1x4,0.75 MAX BUNDLE3051-0001323PIN - PIVOT - LONG9202-0042224PIN - PIVOT - SHORT9202-0043225SHROUD,PSTOP,BELLOWS MTG9411-0066126BAR,BELLOWS MTG,PSTOP,TOP9411-0076227LEVER WAND,RELEASE,PSTOP-M9411-0091128PSTOP RIG SENSOR BAR PIN9411-0103129PSTOP RIG SENSOR CONNECTION9411-0104130PSTOP RIG SENSOR BAR9411-0105131TBG, RIG SENSOR BAR SPACER9411-0107132TUBE9412-0161233BAR,BELLOWS MTG,PSTOP,FRONT9412-0201134BAR,BELLOWS MTG,PSTOP,SIDE9412-0202235SCISSOR LIFT ASSY,PSTOP9413-0062136SPACER ASSY,PSTOP-M,YLW DICH9413-0068137PROX SWITCH ASSY, UPPER9413-0112138PSTOP LIP DEFLECTOR9413-0121139PSTOP,RELEASE LEVER ASSY9413-0122140POWERSTOP HOOK WELDMENT9413-0123141POWERSTOP HOOK WELDMENT9413-01271FINAL BASE WLDT - 27" - PSTOP9414-0083142LABELS,4"X2" THERMAL TRANSFERXMS1-0529143A
TOLERANCES(UNLESS OTHERWISE NOTED)
FRACTIONAL: 1/32"DECIMAL: .00 = .01"
.000 = .005"
ANGULAR: 1
DRAWN BYBDK
L o a d i n g D o c k E q u i p m e n t
This print is the property of Systems, Inc. and represents a proprietary article in which Systems, Inc. retains any and all patof use and/or manufacture and/or sale. Possession of this print does not convey any permission to reproduce, print or manufactusuch permission to be granted only by written authorization signed by an officer or other authorized agent of Systems,Inc. ther
MATERIAL
FINAL ASM - PSTOP/STOPTITE 2018
(26.05)
(29.31)
3
4
NOTE DESCRIPTION1 0.688" X 17.500" VELCRO STRIPS COME ATTACHED TO BELLOWS.2 DLM DECAL OPTION3 USED ONLY WHEN SHIPPING4 ITEMS TO BE SHIPPED LOOSE WITH UNIT5 ITEMS NOT REQUIRED ON UNITS WITH MANUAL LIGHTS
(27.19)
(15.50)
1237
38
18
40
2
20
17
39
33
42727 4
28
4
3
N 17-077 11/15/2017 RELEASED FOR PRODUCTIONM BDK 11/15/2017L BDK 11/9/2017
K BDK 10/25/2017
5
5
5
5
6
5
5555Bracket
Up
Store Operating wandby hanging in slot
Mount StopTite operating wand bracket on the interior wall near the vehicle restraint (or as close to the control box as possible, if equipped). Mounting hardware supplied by others.
Ensure bracket is not mounted upside-down or bracket will be unable to hold operating wand.
A continuing product improvement process is in effect at Systems, Inc. We reserve the right to make product changes without prior notice.McGuire• Division of Systems, Inc. • Phone: 800-624-8473 • Email: [email protected] • www.wbmcguire.com
Automatic Vehicle Restraint
STOP-TITE® SERIESInstallation Overview
V e h i c l e R e s t r a i n t
BUMPERS
96"
1138"
5"
A
19"
8"
1678"
CAUTION
24"
10"
14"
FRACTIONAL: ±1/32"
.00 = ±.01" .000 = ±.005" ANGULAR: ±1°
SPECIFIED, ALL DIMENSIONSARE IN INCHES WITH THE
DECIMAL:
FOLLOWING TOLERANCES:
UNLESS OTHERWISE
MATERIAL
CHK'D
DRAWN BY
DRAWING NO.
DATE
P O W E R A M PM C G U I R E
D L M
S Y S T E M S, I N C.L o a d i n g D o c k E q u i p m e n t
PSTOP-A-7824-4-PD
PIT DETAIL - EH78/PR78/VH78-POWERSTOP-AML/AAL
24" PIT - 4" BUMPERS
BLM
2/10/04
OUTSIDE SIGNALLIGHT ASSEMBLY
4"X4" ELEC. JUNCTION BOX AT POWERSTOP.BY ELECTRICIAN.
DRIVE
4"X4" ELEC. JUNCTION BOX AT PIT.BY ELECTRICIAN.
3" PVC PIPE FOR HYDRAULIC HOSES(FOR COMBINATION LEVELER/RESTRAINT PPAC IN PITOR REMOTE RESTRAINT PPAC IN BUILDING.)WHERE ELBOWS REQ'D, USE SWEEP ELBOWS.BY CONTRACTOR
3" PVC CHASE FOR REMOTE POWER UNITBY CONTRACTOR
FRONT VIEW
3" PVC CHASE FOR COMBO POWER UNITWITH DOCK LEVELER. BY CONTRACTOR
A 18-00312-05-17MOVE J-BOX & PVC AT DOCK FACE5
48"
20"
BUMPERS
SECTION "A-A"
A A
18"
85"
87"
2312" 24"
1 2 43
11"
OUTSIDE SIGNALLIGHT ASSEMBLY
½" CONDUIT FROM THE CONTROL BOX TOOUTSIDE SIGNAL LIGHT ASSEMBLYBY ELECTRICIAN
CONTROL BOX:NEMA 12
34" ELECTRICAL CONDUIT FROM THECONTROL BOX TO THE POWERSTOP JUNCTION BOX. BY ELECTRICIAN.
4"X4" ELEC. JUNCTION BOX AT POWERSTOP.BY ELECTRICIAN.
DRIVE
34" ELECTRICAL CONDUIT FROM THE
CONTROL BOX TO THE PITJUNCTION BOX. BY ELECTRICIAN.
(IF POWERED LEVELER IS REQUIRED)
OPTIONAL WALL MOUNTED IMBED20"H X 20"W
CENTER IN DOCK OPENINGFLUSH WITH BOTTOM OF CURB STEEL.
3" PVC CHASE FOR REMOTE POWER UNITBY CONTRACTOR
3" PVC CHASE FOR COMBO POWER UNITWITH DOCK LEVELER. BY CONTRACTOR
5
48"
A
4” x 4” elec. junction box at restraint.By Electrician.
4” x 4” elec. junction box at pit.By Electrician.
3” PVC pipe for hydraulic hoses(for combination leveler/restraint powerpack in pit or remote restraint powerpack in building.)Where elbows required, use sweep elbows.By Contractor.
Bumpers
Drive
3” PVC chase for combo power unit with dock leveler. By Contractor.
3” PVC chase for remote power unit. By Contractor.
Outside SignalLight Assembly
1/2” conduit from the Control Box to Outside Signal Light Assembly. By Electrician.
3/4” electrical conduit from the Control Box to the PowerStop junction box.
By Electrician.
3/4” electrical conduit from the Control Box to the pit junction box. By Electrician.
(If powered leveler is required)
Control Box:NEMA 12B
20”
10”
14”
96”
19”
8”
5”
11-3/8”
16-7/8”
18”
11”85”
87”
A continuing product improvement process is in effect at Systems, Inc. We reserve the right to make product changes without prior notice.McGuire• Division of Systems, Inc. • Phone: 800-624-8473 • Email: [email protected] • www.wbmcguire.com
Manual Vehicle Restraint
STOP-TITE® SERIESInstallation Overview
V e h i c l e R e s t r a i n t
A continuing product improvement process is in effect at Systems, Inc. We reserve the right to make product changes without prior notice.McGuire• Division of Systems, Inc. • Phone: 800-624-8473 • Email: [email protected] • www.wbmcguire.com
Manual Vehicle Restraint
STOP-TITE® SERIESInstallation Overview
V e h i c l e R e s t r a i n t
STOPTITE - Opt ional L ight Communicat ion SystemMAL
Outside signal l ight assembly by McGuireincluded with Opt ion Ligth Communicat ion System