md120 cats hr005 benco out interface

7
AIM MD.120 INSTALLATION INSTRUCTIONS CITY OF ATLANTA BENCO OUTBOUND INTERFACE Author : Kiran Kumar Kasam. Creation Date : 05 Jul 2006 Last Updated : 05 Jul 2006 Document Ref :- Version : 1.0

Upload: lingesh6b

Post on 03-Dec-2015

218 views

Category:

Documents


3 download

DESCRIPTION

Md120 Cats Hr005 Benco Out Interface

TRANSCRIPT

Page 1: Md120 Cats Hr005 Benco Out Interface

AIM

MD.120 INSTALLATION INSTRUCTIONS CITY OF ATLANTA

BENCOOUTBOUND INTERFACE

Author : Kiran Kumar Kasam.

Creation Date : 05 Jul 2006

Last Updated : 05 Jul 2006

Document Ref : -

Version : 1.0

Page 2: Md120 Cats Hr005 Benco Out Interface

City of Atlanta 05-Jul-2006MD.120 – Installation Instructions, City of Atlanta: BENCO Outbound Interface

Document Control

Change Record1

Date Author Version

Change Reference

05-Jul-06 Kiran Kumar Kasam

1.0 No Previous Document

Reviewers

Name Position

Vijay Lokray Tech Lead (Offshore)

Distribution

Distributed to Location

Library Master Project Library

Note To Holders:

If you receive an electronic copy of this document and print it out, please write your name on the equivalent of the cover page, for document control purposes.

If you receive a hard copy of this document, please write your name on the front cover, for document control purposes.

Page 3: Md120 Cats Hr005 Benco Out Interface

City of Atlanta 05-Jul-2006MD.120 – Installation Instructions, City of Atlanta: BENCO Outbound Interface

Contents

Document Control....................................................................................... ii

Reviewers.............................................................................................. ii

Installation Instructions for BENCO Outbound Interface..............................4

Pre-Installation Steps.............................................................................4Installation Steps...................................................................................4Verification Checklist.............................................................................5UnInstallation Steps...............................................................................6

Open and Closed Issues for this Deliverable...............................................7

Open Issues...........................................................................................7Closed Issues.........................................................................................7

Page 4: Md120 Cats Hr005 Benco Out Interface

City of Atlanta 05-Jul-2006MD.120 – Installation Instructions, City of Atlanta: BENCO Outbound Interface

Installation Instructions for BENCO Outbound Interface

Environment Name: Oracle Applications (R 11.5.10)

Machine: Red Hat Linux 2.4.9

Pre-Installation Steps

Before performing the Setup, please ensure that the following setups are done.

Ensure that the XBOL_TOP exists with the forms, bin, conversion, sql and reports subdirectories in the application server. Make sure that all the directories have required permissions.

Ensure that environment variable $XBOL_TOP is set for the login used in the application server.

Ensure that the XBOL_TOP is registered with Application Object Library.

Ensure that login through which the installation is done contains the read, write and execute permission to the files in $XBOL_TOP in the application server.

Ensure that login through which the installation is done contains the permission to untar files.

Ensure that the common error Handling Package CATS_COMMON_PK and

CATS_ERRORS_PK are compiled in Bolinf

Ensure that the Profile options and Value sets related to this object are defined in application.

Installation Steps

Log into the Application Unix Server.

FTP the following files the $HOME_PATH in Binary mode: CATS_HRMS_BENCO.tar

Untar the tar file using the command

tar -xvf CATS_HRMS_BENCO.tar

Change the mode of the Install Script CATS_HR_BENCO_OUT_INST.sh using the command.

chmod 777 CATS_HR_BENCO_OUT_INST.sh

Run the Installation Script using the

sh CATS_HR_BENCO_OUT_INST.sh |tee BENCO.log

o The Script prompts for APPS Password until a valid Password is entered.

o The Script prompts for BOLINF Password until a valid Password is entered.

Page 5: Md120 Cats Hr005 Benco Out Interface

City of Atlanta 05-Jul-2006MD.120 – Installation Instructions, City of Atlanta: BENCO Outbound Interface

Verification Checklist

Verify that the customization has been properly installed by following these steps:

Check whether all the files listed below are in tar file

o CATS_HR_BENCO_OUT_PK.pls

o CATS_HR_BENCO_OUT_GT.sql

o CATS_HR_BENCO_OUT_CONC.ldt

o CATS_HR_BENCO_ARC_CONC.ldt

o CATS_HR_BENCO_GRRP.ldt

o CATS_HR_BENCO_RLINK.ldt

o CATS_HR_BENCO_RSET.ldt

o CATS_HR_BENCO_OUT_INST.sh

Check whether all the files listed below are in their respective directories.

o CATS_HR_BENCO_OUT_PK.pls in $XBOL_TOP/sql

o CATS_HR_BENCO_OUT_GT.sql in $XBOL_TOP/sql

Check whether the following execuatbe have been defined.

o CATS_HR_BENCO_OUT

Check whether the following concurrent Programs have been defined.

o CATS BENCO Outbound Interface

o CATS BENCO Output File Archiving

Check whether the following Request Set has been defined.

o CATS BENCO Outbound Interface

Check whether the following Request Set has been attached to Cutsom Request Group “CATS Custom”.

o CATS BENCO Outbound Interface

Check whether the following packages are created (Specification and body) in BOLINF schema.

o CATS_HR_BENCO_OUT_PK

Check whether synonyms are created for the following packages in APPS schema.

o CATS_HR_BENCO_OUT_PK

UnInstallation Steps

Not Applicable

Page 6: Md120 Cats Hr005 Benco Out Interface

City of Atlanta 05-Jul-2006MD.120 – Installation Instructions, City of Atlanta: BENCO Outbound Interface

Open and Closed Issues for this Deliverable

Open Issues

ID Issue Resolution Responsibility

Target Date

Impact Date

Closed Issues

ID Issue Resolution Responsibility

Target Date

Impact Date