Measurement report Ray data measurement with color filters Measuring object: Osram OSTAR, 4-chip, with lens Date: 2006-02-09 Page 1/8 Werner-von-Siemens-Str. 10 98693 Ilmenau, GERMANY http://www.technoteam.de Common information Measuring date: 2006-02-07 / 2006-02-08 Person in charge: Knut Bredemeier Measuring object Type: LED, Osram, OSTAR, 4-Chip, with lens Measurement with color filters Two measurements with the color glasses BG25 (blue) and OG530 (yellow) have been done. The ray data of the two measurements are related to the measured luminous flux measured by the V(λ) adapted photometer. For this a factor between the integral of the ray data measured by the camera and the luminous flux measured by the photometer has been calculated. BG 25 - blue OG 530 – yellow Integral of camera data 0.362405 37.1943 Luminous flux of photometer 59.223 59.221 Position and orientation The following views are showing the origin position of the ray data coordinate system referring to the measuring object. The images are captured by the luminance measuring camera at the given angles of the goniometer coordinate system (spherical coordinates). Right view (Theta = 90°, Phi = 0°)

Upload: others

Post on 05-Mar-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Measurement with color filterslight-all.com/Writable/Resource/product/TT/Osram OSTAR... · 2015. 10. 5. · Filter 1: TechnoTeam V(λ) - Filter Filter 2: Schott Glass, OG530, thickness

Measurement report Ray data measurement with color filters Measuring object: Osram OSTAR, 4-chip, with lens Date: 2006-02-09 Page 1/8

Werner-von-Siemens-Str. 1098693 Ilmenau, GERMANY

http://www.technoteam.de

Common information Measuring date: 2006-02-07 / 2006-02-08

Person in charge: Knut Bredemeier

Measuring object Type: LED, Osram, OSTAR, 4-Chip, with lens

Measurement with color filters Two measurements with the color glasses BG25 (blue) and OG530 (yellow) have been done. The ray data of the two measurements are related to the measured luminous flux measured by the V(λ) adapted photometer. For this a factor between the integral of the ray data measured by the camera and the luminous flux measured by the photometer has been calculated.

BG 25 - blue OG 530 – yellow

Integral of camera data 0.362405 37.1943

Luminous flux of photometer 59.223 59.221

Position and orientation The following views are showing the origin position of the ray data coordinate system referring to the measuring object. The images are captured by the luminance measuring camera at the given angles of the goniometer coordinate system (spherical coordinates).

Right view (Theta = 90°, Phi = 0°)

Page 2: Measurement with color filterslight-all.com/Writable/Resource/product/TT/Osram OSTAR... · 2015. 10. 5. · Filter 1: TechnoTeam V(λ) - Filter Filter 2: Schott Glass, OG530, thickness

Measurement report Ray data measurement with color filters Measuring object: Osram OSTAR, 4-chip, with lens Date: 2006-02-09 Page 2/8

Werner-von-Siemens-Str. 1098693 Ilmenau, GERMANY http://www.technoteam.de

Back view (Theta = 90°, Phi = 90°)

Top view (Theta = 0°, Phi = 0°) Goniometer coordinate system

Common operating parameter Power supply: Gossen Metrawatt SPP 500-52

Voltage type: DC

Regulation type: constant current (CC)

Burn-in time: > 45 min.

Common measuring parameter Measuring grid: DeltaTheta = 0.75°, DeltaPhi = 0.75°

Spherical area: Pole cap, +/- 130°

Measuring duration: 2:00h

Page 3: Measurement with color filterslight-all.com/Writable/Resource/product/TT/Osram OSTAR... · 2015. 10. 5. · Filter 1: TechnoTeam V(λ) - Filter Filter 2: Schott Glass, OG530, thickness

Measurement report Ray data measurement with color filters Measuring object: Osram OSTAR, 4-chip, with lens Date: 2006-02-09 Page 3/8

Werner-von-Siemens-Str. 1098693 Ilmenau, GERMANY

http://www.technoteam.de

Measurement – Color filter BG25 (Blue)

Filter Filter 1: TechnoTeam V(λ) - Filter

Filter 2: Schott Glass, BG25, thickness 2.0 mm

Filter 3: Grey filter, Schott Glass, NG 9, thickness 1.91 mm, transmittance 0.0022735

Operating Parameter Laboratory temperature: 23.5°C

Voltage: 11.36 V

Current: 0.0981 A

Power: 1.115 W

Measured luminous flux Luminous flux: 59.224 lm

Comment: The luminous flux has been measured by a V(λ) adapted photometer, independent of the camera measurement .

Light intensity distribution

Polar plot

C0,0-C180,0 C30,0-C210,0 C60,0-C240,0 C90,0-C270,0

90°

105°

120°

135°135°

120°

105°

90°

75° 60° 45° 30° 15° 0° 15° 30° 45° 60° 75°

100

150

200

250

300

cd/klm

Page 4: Measurement with color filterslight-all.com/Writable/Resource/product/TT/Osram OSTAR... · 2015. 10. 5. · Filter 1: TechnoTeam V(λ) - Filter Filter 2: Schott Glass, OG530, thickness

Measurement report Ray data measurement with color filters Measuring object: Osram OSTAR, 4-chip, with lens Date: 2006-02-09 Page 4/8

Werner-von-Siemens-Str. 1098693 Ilmenau, GERMANY

http://www.technoteam.de

3D – View

Output format Pos. Format Filename

1 IES (1.5° x 1.5°), IES95 4ChipWithLens\blue_BG25\lid_15x15.ies

2 LDT (1.5° x 1.5°), EULUM-DAT 4ChipWithLens\blue_BG25\\lid_15x15.ldt

Ray data

Starting points of rays / bounding geometry Type of geometry: Volume (spherical)

Center point: (0, 0, 0)T [mm]

Max radius: 3.4 mm (radius of the lens)

Comment: Starting points of the rays are traced back to the closest distance to the center point. Points with a distance to the center point larger than the given maximum radius have been ignored.

Further information Number of camera images: 86879

Number of measured rays: 783304608

Measured luminous flux: 59.224 lm

Proportion of luminous flux on/inside the bounding geometry: 99.98 %

Number of rays on/inside the bounding geometry: 99.98 %

Page 5: Measurement with color filterslight-all.com/Writable/Resource/product/TT/Osram OSTAR... · 2015. 10. 5. · Filter 1: TechnoTeam V(λ) - Filter Filter 2: Schott Glass, OG530, thickness

Measurement report Ray data measurement with color filters Measuring object: Osram OSTAR, 4-chip, with lens Date: 2006-02-09 Page 5/8

Werner-von-Siemens-Str. 1098693 Ilmenau, GERMANY

http://www.technoteam.de Ray data randomized: yes

Output format Pos. Format Number of rays *) Filename

1 ASAP (*.dis) 1e6 4ChipWithLens\ blue_BG25\1e6.dis

2 ASAP (*.dis) 5e6 4ChipWithLens\ blue_BG25\5e6.dis

3 ASAP (*.dis) 10e6 4ChipWithLens\ blue_BG25\10e6.dis

4 ASAP (*.dis) 20e6 4ChipWithLens\ blue_BG25\20e6.dis

*)

The given number of rays is the target specification to the ray data generation from the measured rays. Rays not hitting the given geometry has been ignored, so that the number of rays in the target format is lower by this amount.

Page 6: Measurement with color filterslight-all.com/Writable/Resource/product/TT/Osram OSTAR... · 2015. 10. 5. · Filter 1: TechnoTeam V(λ) - Filter Filter 2: Schott Glass, OG530, thickness

Measurement report Ray data measurement with color filters Measuring object: Osram OSTAR, 4-chip, with lens Date: 2006-02-09 Page 6/8

Werner-von-Siemens-Str. 1098693 Ilmenau, GERMANY

http://www.technoteam.de

Measurement – Color filter OG530 (Yellow)

Filter Filter 1: TechnoTeam V(λ) - Filter

Filter 2: Schott Glass, OG530, thickness 2.0 mm

Filter 3: Grey filter, Schott Glass, NG 9, thickness 1.91 mm, transmittance 0.0022735

Operating Parameter Laboratory temperature: 22.0°C

Voltage: 11.35 V

Current: 0.0981 A

Power: 1.114 W

Measured luminous flux Luminous flux: 59.221 lm

Comment: The luminous flux has been measured by a V(λ) adapted photometer, independent of the camera measurement .

Light intensity distribution

Polar plot

C0,0-C180,0 C30,0-C210,0 C60,0-C240,0 C90,0-C270,0

90°

105°

120°

135°135°

120°

105°

90°

75° 60° 45° 30° 15° 0° 15° 30° 45° 60° 75°

100

150

200

cd/klm

Page 7: Measurement with color filterslight-all.com/Writable/Resource/product/TT/Osram OSTAR... · 2015. 10. 5. · Filter 1: TechnoTeam V(λ) - Filter Filter 2: Schott Glass, OG530, thickness

Measurement report Ray data measurement with color filters Measuring object: Osram OSTAR, 4-chip, with lens Date: 2006-02-09 Page 7/8

Werner-von-Siemens-Str. 1098693 Ilmenau, GERMANY

http://www.technoteam.de

3D – View

Output format Pos. Format Filename

1 IES (1.5° x 1.5°), IES95 4ChipWithLens\yellow_ OG530\lid_15x15.ies

2 LDT (1.5° x 1.5°), EULUM-DAT 4ChipWithLens\yellow_OG530\\lid_15x15.ldt

Ray data

Starting points of rays / bounding geometry Type of geometry: Volume (spherical)

Center point: (0, 0, 0)T [mm]

Max radius: 3.4 mm (radius of the lens)

Comment: Starting points of the rays are traced back to the closest distance to the center point. Points with a distance to the center point larger than the given maximum radius have been ignored.

Further information Number of camera images: 86881

Number of measured rays: 746292085

Measured luminous flux: 59.221 lm

Proportion of luminous flux on/inside the bounding geometry: 99.84 %

Number of rays on/inside the bounding geometry: 99.84 %

Page 8: Measurement with color filterslight-all.com/Writable/Resource/product/TT/Osram OSTAR... · 2015. 10. 5. · Filter 1: TechnoTeam V(λ) - Filter Filter 2: Schott Glass, OG530, thickness

Measurement report Ray data measurement with color filters Measuring object: Osram OSTAR, 4-chip, with lens Date: 2006-02-09 Page 8/8

Werner-von-Siemens-Str. 1098693 Ilmenau, GERMANY

http://www.technoteam.de Ray data randomized: yes

Output format Pos. Format Number of rays *) Filename

1 ASAP (*.dis) 1e6 4ChipWithLens\yellow_ OG530\1e6.dis

2 ASAP (*.dis) 5e6 4ChipWithLens\yellow_ OG530\5e6.dis

3 ASAP (*.dis) 10e6 4ChipWithLens\yellow_ OG530\10e6.dis

4 ASAP (*.dis) 20e6 4ChipWithLens\yellow_ OG530\20e6.dis

*)

The given number of rays is the target specification to the ray data generation from the measured rays. Rays not hitting the given geometry has been ignored, so that the number of rays in the target format is lower by this amount.