Measuring end- expiratory lung volume Giacomo Bellani, M.D., Ph.D. University of Milano-Bicocca Monza, Italy [email protected]

Upload: ivy

Post on 14-Jan-2016

61 views

Category:

Documents


0 download

DESCRIPTION

Measuring end-expiratory lung volume. Giacomo Bellani , M.D., Ph.D . University of Milano-Bicocca Monza, Italy [email protected]. Conflicts of interest. Personal: Lecturing fees from GE Institutional , research grants from: Draeger Maquet Chiesi Farmaceutici. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Measuring end-expiratory lung volume

Measuring end-expiratory lung volume

Giacomo Bellani, M.D., Ph.D.University of Milano-Bicocca

Monza, [email protected]

Page 2: Measuring end-expiratory lung volume

Conflicts of interest

Personal:• Lecturing fees from GE

Institutional, research grants from:• Draeger• Maquet• Chiesi Farmaceutici

Page 3: Measuring end-expiratory lung volume

Which «lung volume» ?

Functional Residual Capacity (FRC)Functional Residual Capacity (FRC)Volume of gas in the lung at the end of a physiologic Volume of gas in the lung at the end of a physiologic

expiration expiration Relaxation volume of respiratory systemRelaxation volume of respiratory system

End Expiratory Lung Volume (EELV)End Expiratory Lung Volume (EELV)Volume of gas in the lung at end expiration during Volume of gas in the lung at end expiration during mechanical ventilation with PEEPmechanical ventilation with PEEP

EELV @ 0 cmH2O= FRC

Page 4: Measuring end-expiratory lung volume

• How do we measure End-expiratory lung volume?

• Why should we measure end-expiratory lung volume?

Page 5: Measuring end-expiratory lung volume

TechniquesCT scan

• Precise quantitative assessment• Radiological exposure+patient transfer

Closed circuit• Need for a dedicated tracer+closed system• No need for «fast» response concentration

measurements - offline measurementOpen circuit muti-breath washin/washout

• Potentially no need for a gas tracer• Fast response measurement, synchrony with tidal

ventilation

Page 6: Measuring end-expiratory lung volume

TechniquesCT scan

• Precise quantitative assessment• Radiological exposure+patient transfer

Closed circuit• Need for a dedicated tracer+closed system• No need for «fast» response concentration

measurements - offline measurementOpen circuit muti-breath washin/washout

• Potentially no need for a gas tracer• Fast response measurement, synchrony with tidal

ventilation

Page 7: Measuring end-expiratory lung volume

Closed Dilution Technique

VVff = V = Vii + EELV + EELV

Mass conservation

CiCiViVi

FRC ?FRC ?

CfCfVfVf

ViViCfCfCiCi

ViViEELVEELV -=

VVii* C* Cii = V = Vff* C* Cff

Page 8: Measuring end-expiratory lung volume
Page 9: Measuring end-expiratory lung volume

TechniquesCT scan

• Precise quantitative assessment• Radiological exposure+patient transfer

Closed circuit• Need for a dedicated tracer+closed system• No need for «fast» response concentration

measurements - offline measurementOpen circuit muti-breath washin/washout

• Potentially no need for a gas tracer• Fast response measurement, synchrony with tidal

ventilation

Page 10: Measuring end-expiratory lung volume

70 %

30 %O2

N2

50 %

50 %

FiN2=70%

Vt

FeN2

600 ml

1400 ml

1000 ml

1000 ml ml.

ml

..

Nml2000

20

400

5070

400 2

Page 11: Measuring end-expiratory lung volume

Multibreath nitrogen washout

Wrigge H et al Intensive Care Med 1998; 24: 487

Off-line correction of viscosity effect on sidestream delay time and pneumothacografic measurments

Page 12: Measuring end-expiratory lung volume

Derives N2 concentration from: 100%- [CO2]- [CO2]

Uses end-tidal concentration (no need for synchronization)

Page 13: Measuring end-expiratory lung volume
Page 14: Measuring end-expiratory lung volume

What about Pressure Support ?

0

1000

2000

3000

4000

0 1000 2000 3000 4000

EELV by He dilution (ml)

EE

LV

by

GE

En

gst

rom

(m

l)Volume Control

R2 = 0.8353

Pressure Support

Using a 20% variation in FiO2:

Bellani G, unpublished

Page 15: Measuring end-expiratory lung volume

FRC INview (Engstrom carestation)

Page 16: Measuring end-expiratory lung volume
Page 17: Measuring end-expiratory lung volume
Page 18: Measuring end-expiratory lung volume

• How do we measure End-expiratory lung volume?

• Why should we measure end-expiratory lung volume?

Page 19: Measuring end-expiratory lung volume

EELV is profoundly reduced in ARDS• Estimate of alveolar

recruitment• Determinant of VILI

Why should we measure end-expiratory lung volume?

Page 20: Measuring end-expiratory lung volume

EELV is profoundly reduced in ARDS

• Estimate of alveolar recruitment

• Determinant of VILI

Why should we measure end-expiratory lung volume?

Page 21: Measuring end-expiratory lung volume

Alveolar recruitment by P-V curve

Maggiore S. et al, Am J Resp Crit Care Med, 2001

Page 22: Measuring end-expiratory lung volume

Effect of recruitment on FRC (0 cmH2O)

Page 23: Measuring end-expiratory lung volume

Patroniti N et al., CCM 2010

Page 24: Measuring end-expiratory lung volume

A simplified approachAssessing alveolar recruitment by EELV

PEEP = 0

Compliance=30 ml/cmH2OEELV= 1000 ml

PEEP=10

Expected EELV increase: 30 * 10= 300 ml

No recruitmentEELV= 1300 ml

RecruitmentEELV = 1600 ml

Page 25: Measuring end-expiratory lung volume

0

0.2

0.4

0.6

0.8

1

1.2

1.4

1.6

1.8

2

4 14

PEEP (cmH2O)

EE

LV

(l)

0

5

10

15

20

25

30

35

Crs

(m

l/cm

H2O

)

6 8 10 12

1350 ml

Crs 29 expected EELV increase 174 ml

1524 l

1950 l

true EELV increase 600 ml

∆EELV / PEEP change = 600 / 6 = 100 ml/cmH2O

Page 26: Measuring end-expiratory lung volume
Page 27: Measuring end-expiratory lung volume
Page 28: Measuring end-expiratory lung volume

EELV is profoundly reduced in ARDS• Estimate of alveolar

recruitment• Determinant of VILI

Why should we measure end-expiratory lung volume?

Page 29: Measuring end-expiratory lung volume

EELV

VE (L/min)

RATIO

NORMAL

ARDS

2500 < 7 < 2.8

1000 > 15 > 15

SPECIFIC HYPERVENTILATION

Page 30: Measuring end-expiratory lung volume

Vt/F

RC

Page 31: Measuring end-expiratory lung volume

End-expiration End-inspiration PETEELVnormally-aerated

Vtnormally-aerated

Kinormally-aerated

High activity

Low activity

- 1000

100

-500

Regional distension and inflammation

Bellani G et al., Am J Resp Crit Care Med, 2011

Page 32: Measuring end-expiratory lung volume

The role of tidal volume/EELV

Bellani G et al., Am J Resp Crit Care Med, 2011

Page 33: Measuring end-expiratory lung volume
Page 34: Measuring end-expiratory lung volume

Conclusions:o Measurement of end-expiratory lung volume is

now available:RESEARCH TOOL → CLINICAL TOOL

o Useful in estimating lung recruitmentoCan it help in setting PEEP? Yeso Is it being used to set PEEP? Don’t know

o Possible role in adjusting tidal volume?