measuring sub-50nm particle retention of upw filters – the particles are very uniform in size (cv...
TRANSCRIPT
![Page 1: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/1.jpg)
CT Associates, Inc. CT Associates, Inc.
Measuring sub-50nm particle retention of UPW filters
Don Grant and Gary Van Schooneveld
CT Associates, Inc.
7121 Shady Oak Road, Eden Prairie, MN 55344
May 2, 2011
1 CTA 1286 2519
![Page 2: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/2.jpg)
CT Associates, Inc. CT Associates, Inc
Introduction
• The critical feature size of state-of-the-art semiconductor devices is on the order of 40 nm and expected to decrease to < 20 nm by 2015.
• Particles half the size of critical features can reduce finished device yield and reliability.
• Particles in UPW that contacts wafer surfaces during processing can deposit on the wafer surface.
• Microfilters and ultrafilters are used to remove particles from these liquids.
• Test methods are needed to measure the filter particle removal efficiency of particles smaller than 50 nm.
CTA 1286 2519 Slide # 2
![Page 3: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/3.jpg)
CT Associates, Inc. CT Associates, Inc
Outline
• Introduction
• Desired test method characteristics
• Comparison of candidate challenge particle properties
• Examples of retention of candidate test particles by a 30 nm UPW filter
• Summary and conclusions
CTA 1286 2519 Slide # 3
![Page 4: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/4.jpg)
CT Associates, Inc. CT Associates, Inc
Desired test method properties
• Testing should simulate “real-world” worst case conditions. – Particle size should be well characterized.
– Particle capture should be by sieving only.
– Particles used in testing should be representative of particles found in UPW systems.
• The test procedure should simulate filter performance during its projected lifetime in a reasonable test period – Operate at a face velocity (flow rate/surface area) similar to actual use
conditions.
– Example of a reasonable test duration - simulate 1 year in a 16 hour test.
• The cost per cartridge test should not be prohibitively expensive.
CTA 1286 2519 Slide # 4
![Page 5: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/5.jpg)
CT Associates, Inc. CT Associates, Inc
Particle capture mechanisms
• Particle capture by filters can result from several mechanisms including: – Diffusion
– Interception
– Impaction
– Electrostatic attraction
– Sieving
• Particle capture should be by sieving only – Worst case capture mechanism
– Capture by diffusion, interception, impaction and electostatic attraction and adsorption should be absent (or nearly absent).
– Desire a strong repulsive force and a weak attractive (Van der Waals) force between the particles and the membrane surface to minimize the potential for adsorption.
CTA 1286 2519 Slide # 5
![Page 6: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/6.jpg)
CT Associates, Inc. CT Associates, Inc
Removal of particle from UPW by a 0.2 µm rated filter by different capture mechanisms
CTA 1286 2519 Slide # 6
Particle diameter (µm)
0.01 0.1 1
Filt
er
rete
ntio
n (
LR
V)
0
10
20
30
40
Capture by interceptionplus diffusion
Capture bysieving
![Page 7: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/7.jpg)
CT Associates, Inc. CT Associates, Inc
This study
• Focused on particle type.
• Measured the retention of different types of particles by a 30 nm commercially-available UPW filter cartridges.
• Particle types evaluated – Polystyrene latex (PSL)
– Colloidal gold
– Colloidal silica
• Test conditions employed – Filters were operated at a face velocity of 0.11 cm/min (equivalent to
~1.1 liters/min in a 10” cartridge). • Lower than actual use conditions.
• Chosen due to the high cost of gold particles.
– Inlet particle concentration – 2E8/mL (~6 ppb)
– Total challenge resulted in a fractional filter coverage of 0.2 monolayers
CTA 1286 2519 Slide # 7
![Page 8: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/8.jpg)
CT Associates, Inc. CT Associates, Inc
Particle comparison
• Size distributions
• Anticipated capture mechanisms
• “Real worldliness”
• Cost
CTA 1286 2519 Slide # 8
![Page 9: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/9.jpg)
CT Associates, Inc. CT Associates, Inc
Liquid Nanoparticle Sizer Description
Dynamic Mobility Analyzer (DMA)
Condensation Particle Counter (CPC)
Operating Principle •Nebulizer converts the hydrosol to an aerosol. •DMA separates particles according to size. •CPC measures concentrations of particles of each size.
Slide # 9 CTA 1286 2519
FilterChallenge Solution
CDA
UPW
UltrafineNebulizer
Scanning Mobility Particle Sizer (SMPS)ParticleAerosol
Pressureregulator
Drain
Neutralizer DMA CPCmonodispersed
aerosol
![Page 10: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/10.jpg)
CT Associates, Inc. CT Associates, Inc CTA 1286 2519 Slide # 10
50 nm PSL 3050A-3490 - Multiple dilution ratios
Particle diameter (nm)
5 6 7 8 9 15 20 25 30 35 40 50 60 70 80 9010 100
Diffe
ren
tial num
be
r co
ncen
tra
tion
d (
#/m
L)
/ d log(D
P)
0.0
5.0e+14
1.0e+15
1.5e+15
2.0e+15
1,800:1
6,000:1
18,000:1
60,000:1
180,000:1
100nm PSL - Multiple dilutions
Particle diameter (nm)
5 6 7 8 9 15 20 25 30 35 40 50 60 70 80 9010 100
Diffe
ren
tia
l n
um
be
r co
nce
ntr
atio
n
d (
#/c
m3)
/ d
lo
g(D
P)
0
200
400
600
800
55.4 uL/mL 12/2/09
55.4 uL/mL 12/3/09
50.3 uL/mL 12/3/09
54.3 uL/mL 12/3/09
66.4 uL/mL 12/4/09
63.7 uL/mL 12/4/09
30nm PSL Suspension Stability
Particle diameter (nm)
5 6 7 8 9 15 20 25 30 35 40 50 60 70 80 9010 100
Diffe
ren
tial n
um
be
r co
nce
ntr
ation
d (
#/m
L)
/ d
log
(DP)
0.0
5.0e+12
1.0e+13
1.5e+13
2.0e+13
2.5e+13
Initial
18 days
20 nm PSL - Multiple dilution ratios
Particle diameter (nm)
5 6 7 8 9 15 20 25 30 35 40 50 60 70 80 9010 100
Diffe
ren
tial num
be
r co
ncen
tra
tion
d (
#/m
L)
/ d log(D
P)
0.0
1.0e+16
2.0e+16
3.0e+16
4.0e+16
5.0e+16
155,000:1
310,000:1
710,000:1
1,430,000:1
Examples of PSL particle size distributions
![Page 11: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/11.jpg)
CT Associates, Inc. CT Associates, Inc
What size are the 20nm PSL particles?????
CTA 1286 2519 Slide # 11
20 nm PSL - Number weighted distribution
Particle diameter (nm)
5 6 7 8 9 15 20 25 30 35 40 50 60 70 80 9010 100
Diffe
ren
tia
l n
um
be
r co
nce
ntr
atio
nd
(#
/mL
) / d
lo
g(D
P)
0.0
1.0e+16
2.0e+16
3.0e+16
4.0e+16
5.0e+16
155,000:1
310,000:1
710,000:1
20 nm PSL - Volume weighted distribution
Particle diameter (nm)
5 6 7 8 9 15 20 25 30 35 40 50 60 70 80 9010 100
Diffe
ren
tial volu
me
co
ncen
tra
tion
d (
nm
3/m
L)
/ d log(D
P)
0.0
1.0e+19
2.0e+19
3.0e+19
4.0e+19
5.0e+19
155,000:1
310,000:1
710,000:1
![Page 12: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/12.jpg)
CT Associates, Inc. CT Associates, Inc
What’s the small stuff in the PSL????
CTA 1286 2519 Slide # 12
50 nm PSL 3050A-3490
Particle diameter (nm)
5 6 7 8 9 15 20 25 30 35 40 50 60 70 80 9010 100
Diffe
ren
tia
l n
um
be
r co
nce
ntr
atio
nd
(#
/mL
) / d
lo
g(D
P)
0.0
5.0e+14
1.0e+15
1.5e+15
2.0e+15
1,800:1
6,000:1
18,000:1
60,000:1
180,000:1
Measurement of 0.1% TM40 particles and 1% sucrose
Particle diameter (nm)
5 6 7 8 9 15 20 25 30 35 40 50 60 70 80 9010 100D
iffe
ren
tia
l n
um
be
r co
nce
ntr
atio
nd
(#
/mL
) / d
lo
g (
DP)
0
1e+14
2e+14
3e+14
4e+14
5e+14
6e+14
7e+14
8e+14
2,000:1
6,700:1
20,000:1
67,000:1
200,000:1
Particles!!!!
![Page 13: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/13.jpg)
CT Associates, Inc. CT Associates, Inc
Diafiltered 10nm (9.3nm) Gold particles
Particle diameter (nm)
5 6 7 8 9 20 30 40 50 60 70 80 9010 100
Diffe
rentia
l num
ber
concen
tration
d (
#/m
L)
/ d lo
g (
DP)
0.0
2.5e+13
5.0e+13
7.5e+13
1.0e+14
1.3e+14
1.5e+14
20 nm (20.3) BBI gold particles
Particle diameter (nm)
5 6 7 8 9 15 20 25 30 35 40 50 60 70 80 9010 100
Diffe
rential num
ber
con
centr
ation
d (
#/m
L)
/ d log (
DP)
0.0
2.0e+12
4.0e+12
6.0e+12
8.0e+12
1.0e+13
1.2e+13
1.4e+13
1.6e+13
Slide # 13 CTA 1286 2519
Sizing of gold nanoparticles from BBI
30 nm (30.3) BBI gold particles
Particle diameter (nm)
5 6 7 8 9 15 20 25 30 35 40 50 60 70 80 9010 100
Diffe
rential num
ber
con
centr
ation
d (
#/m
L)
/ d log (
DP)
0.0
1.0e+12
2.0e+12
3.0e+12
4.0e+12Mixture of 20 (20.3) and 30 (30.3) nm BBI gold particles
Particle diameter (nm)
5 6 7 8 9 15 20 25 30 35 40 50 60 70 80 9010 100
Diffe
rential num
ber
con
centr
ation
d (
#/m
L)
/ d log (
DP)
0.0
5.0e+11
1.0e+12
1.5e+12
2.0e+12
2.5e+12
![Page 14: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/14.jpg)
CT Associates, Inc. CT Associates, Inc
Fraction of particles exceeding size (%)
1 2 5 10 20 30 50 70 80 90 95 98 99
Pa
rtic
le d
iam
ete
r (n
m)
0
5
10
15
20
25
30
35
40
9.3 nm
20.3 nm
30.3 nm
Mean (nm) CV (%) Mean (nm) CV (%)
10 9.3 < 15 8.4 13
20 20.3 < 8 20.8 7.4
30 30.3 < 8 30.5 7.3
Claimed size Measured sizeNominal Size (nm)
Comparison between claimed and measured gold nanoparticle sizes (from BBI)
CTA 1286 2519 Slide # 14
![Page 15: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/15.jpg)
CT Associates, Inc. CT Associates, Inc
Size distributions of Ludox® Colloidal Silica Particles
CTA 1286 2519 Slide # 15
Particle diameter (nm)
5 6 7 8 9 20 30 40 50 60 70 80 9010 100
Diffe
ren
tia
l n
um
be
r co
nce
ntr
atio
nd
(#
/mL
) / d lo
g (
DP)
0.00
2.50e+16
5.00e+16
7.50e+16
1.00e+17
1.25e+17
1.50e+17
SM30
HS40
TM40
® Grace Davison
![Page 16: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/16.jpg)
CT Associates, Inc. CT Associates, Inc
Particle size distributions
• Polystyrene latex – Available in “mono-dispersed” sizes of 20, 30, 40, 50 nm, etc. – Particles smaller than about 50 nm are not very uniform in size.
• The standard deviation of particle diameters is approximately 6 nm.; regardless of mean size. • This results in CVs of ~6% and ~30% for 100 and 20 nm particles; respectively.
– Suspensions contain high concentrations of small particles. – Suspensions contain moderate surfactant concentrations to stabilize the particles.
• Colloidal gold – Available in “mono-dispersed” sizes of 5, 10, 15, 20, 25, 30 nm, and larger. – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species.
• Colloidal silica – Available with median sizes of 12, 18, and 28 nm (possibly also smaller sizes). – The 28 nm particles are very uniform in size (CV < 10%); the 12nm and 18nm are
less uniform. – Contain low concentrations of dissolved species.
CTA 1286 2519 Slide # 16
![Page 17: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/17.jpg)
CT Associates, Inc. CT Associates, Inc
Particle capture mechanisms
• Particle capture by filters can result from several mechanisms including: – Diffusion
– Interception
– Impaction
– Electrostatic attraction
– Sieving
• Particle capture should be by sieving only – Worst case capture mechanism
– Capture by diffusion, interception, impaction and electostatic attraction and adsorption should be absent (or nearly absent).
– Desire a strong repulsive force and a weak attractive (Van der Waals) force between the particles and the membrane surface to minimize the potential for adsorption.
CTA 1286 2519 Slide # 17
![Page 18: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/18.jpg)
CT Associates, Inc. CT Associates, Inc
Anticipated particle capture mechanisms • PSL
– Particle zeta potential (-16 mV) predicts a moderate particle-membrane repulsive force in most cases.
– Particle composition predicts a large particle-membrane attractive force in most cases.
– Tests with multiple membrane types indicate significant non-sieving particle capture occurs.
– Non-sieving capture can be eliminated if surfactant is added to the challenge – not a real-world situation.
• Colloidal gold – Particle zeta potential (-11 mV) predicts a low to moderate particle-membrane repulsive force in most
cases.
– Particle composition predicts a moderate particle-membrane attractive force in most cases.
– The solution in which the purchased particles are suspended contains a high concentration of dissolved conductive material.
– Tests with multiple membrane types indicate significant non-sieving particle capture occurs.
– Non-sieving capture can be reduced/eliminated by modifying the surface of the particles.
• Colloidal silica – Particle zeta potential (-16 mV) predicts a moderate particle-membrane repulsive force in most cases.
– Particle composition predicts a weak particle-membrane attractive force in most cases.
– Tests with multiple membrane types indicate little if any non-sieving particle capture.
CTA 1286 2519 Slide # 18
![Page 19: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/19.jpg)
CT Associates, Inc. CT Associates, Inc
Particle “real-worldliness”
• PSL
– The particles are plastic spheres and are not believed to be representative of particles in UPW systems.
• Colloidal gold
– The particles are not believed to be representative of particles in UPW systems.
• Colloidal silica
– UPW systems are known to contain colloidal silica.
CTA 1286 2519 Slide # 19
![Page 20: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/20.jpg)
CT Associates, Inc. CT Associates, Inc
Particle comparison
Particle Type
Sizes Available
“Real World”? Sieving only? Cost of
particles per gram
PSL Yes No Can be achieved by adding
surfactant. $1,800
Colloidal Gold
Yes No Can be achieved by surface
modification. $23,000
Colloidal Silica
Yes Yes Yes $0.08
CTA 1286 2519 Slide # 20
Colloidal silica appears to be the best choice.
![Page 21: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/21.jpg)
CT Associates, Inc. CT Associates, Inc
Filter cartridge testing
• Cartridges were challenged with 3 types of 30 nm particles (PSL, colloidal gold, colloidal silica)
• Three separate cartridges were tested.
• Each cartridge was challenged with multiple particle types. The challenge order was varied amongst the cartridges.
• One cartridge was also challenged with a mixture of 15 nm colloidal gold and 30 nm colloidal silica particles.
CTA 1286 2519 Slide # 21
![Page 22: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/22.jpg)
CT Associates, Inc. CT Associates, Inc
Filter test system schematic
LNS filter retention overview 03-17-11 Slide # 22
Particlesuspension
Testfilter
UltrafineAtomizer
ScanningMobilityParticle
Sizer
UPW
Pressureregulator
Vent
Liquid Nanoparticle
Sizer
![Page 23: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/23.jpg)
CT Associates, Inc. CT Associates, Inc
Test Procedure
• The cartridges was flushed until the filtrate approached the system background concentration (106/mL > 10 nm).
• The filter was challenged with 2E8 particles/mL (~6 ppb).
• The challenge concentration was verified.
• The face velocity throughout the test was 0.11 cm/min.
CTA 1286 2519 Slide # 23
![Page 24: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/24.jpg)
CT Associates, Inc. CT Associates, Inc CTA 1286 2519 Slide # 24
Fractional coverage (Monolayers)
0.000 0.025 0.050 0.075 0.100 0.125 0.150 0.175 0.200
Re
tention (
%)
0
20
40
60
80
100
Silica
PSL
Gold
High retention of PSL particles
Low retention of silica particles.
Retention of PSL followed by silica (Cartridge #1)
![Page 25: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/25.jpg)
CT Associates, Inc. CT Associates, Inc CTA 1286 2519 Slide # 25
Fractional coverage (Monolayers)
0.000 0.025 0.050 0.075 0.100 0.125 0.150 0.175 0.200
Re
tention (
%)
0
20
40
60
80
100
Silica
PSL
Gold
High retention of gold particles.
Low retention of silica particles.
Retention of gold followed by silica (Cartridge #2)
![Page 26: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/26.jpg)
CT Associates, Inc. CT Associates, Inc CTA 1286 2519 Slide # 26
Fractional coverage (Monolayers)
0.000 0.025 0.050 0.075 0.100 0.125 0.150 0.175 0.200
Re
tention (
%)
0
20
40
60
80
100
Silica
PSL
Gold
High retention of gold and PSL
particles.
Low retention of silica particles.
Initially counting silica rather than PSL particles.
Retention of multiple particle types (Cartridge #3)
![Page 27: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/27.jpg)
CT Associates, Inc. CT Associates, Inc
Retention of different 30nm particles types by a commercially available
UPW filter cartridges
CTA 1286 2519 27
Fractional coverage (Monolayers)
0.000 0.025 0.050 0.075 0.100 0.125 0.150 0.175 0.200
Re
tentio
n (
%)
0
20
40
60
80
100
Silica
PSL
Gold
Fractional coverage (Monolayers)
0.000 0.025 0.050 0.075 0.100 0.125 0.150 0.175 0.200
Re
tention (
%)
0
20
40
60
80
100
Silica
PSL
Gold
Fractional coverage (Monolayers)
0.000 0.025 0.050 0.075 0.100 0.125 0.150 0.175 0.200
Re
tention (
%)
0
20
40
60
80
100
Silica
PSL
Gold
•3 separate filters were tested. •Each was tested with a sequence of particle types. •In all cases the challenge concentration was 2E8/mL.
![Page 28: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/28.jpg)
CT Associates, Inc. CT Associates, Inc
Retention of a mixture of 15 nm gold and 30 nm silica by a commercially available UPW filter
CTA 1286 2519 Slide # 28
Particle diameter (nm)
15 20 25 30 35 40 45 5010
Diffe
ren
tia
l n
um
be
r co
nce
ntr
atio
nd
(#
/mL
) / d
lo
g D
P)
0.0
2.0e+10
4.0e+10
6.0e+10
8.0e+10
1.0e+11
Challenge (3-6 hours)
Filtrate at 3 hours
Filtrate at 6 hours
•Challenged with 3E8/mL gold particles only for first 3 hours •Then 3E8/mL gold + 3E8/mL silica particles for next 3 hours.
![Page 29: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/29.jpg)
CT Associates, Inc. CT Associates, Inc
Retention of a mixture of 15 nm gold and 30 nm silica by a commercially available UPW filter
CTA 1286 2519 Slide # 29
Time (hours)
0 1 2 3 4 5 6
Re
ten
tio
n (
%)
0
10
20
30
40
50
60
70
80
90
100
15 nm Gold particles
28 nm Silica particles
•Challenged with 3E9/mL gold particles only for first 3 hours. •Then 3E9/mL gold + 3E9/mL silica particles for next 3 hours.
Moderate retention of 15 nm gold particles.
Low retention of 30 nm silica particles.
![Page 30: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/30.jpg)
CT Associates, Inc. CT Associates, Inc
Particle retention comparison
• Retention of PSL and gold particles was significantly higher than silica particles.
• Retention of silica particles is predominately by sieving while PSL and gold particles are likely removed by several capture mechanisms.
• Silica is the preferred particle type for UPW filter retention testing.
CTA 1286 2519 Slide # 30
![Page 31: Measuring sub-50nm particle retention of UPW filters – The particles are very uniform in size (CV around 8%.) – Suspensions contain high concentrations of dissolved species. •](https://reader033.vdocument.in/reader033/viewer/2022053002/5f062c927e708231d416aa2a/html5/thumbnails/31.jpg)
CT Associates, Inc. CT Associates, Inc
Summary and conclusions
• Test methods to measure the retention of sub-50nm particles by UPW filters are needed.
• The methods should:
– Use real-world particles that are removed by sieving ,
– Test the filter under representative conditions of particle concentration, particle loading and face velocity
– Be applicable to cartridges as well as filter samples.
– Not be cost prohibitive.
• Filter retention tests performed with PSL, gold, and silica 30 nm particles indicated that silica is the preferred challenge particle.
CTA 1286 2519 Slide # 31