mechanical clot detection stago’s viscosity-based clot detection system

50
Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Upload: maud-harper

Post on 25-Dec-2015

248 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Mechanical Clot Detection

Stago’s Viscosity-based Clot Detection System

Page 2: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Viscosity based Detection Viscosity based Detection SystemSystem

Page 3: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Viscosity based Detection Viscosity based Detection SystemSystem

Page 4: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Viscosity based Detection Viscosity based Detection SystemSystem

Page 5: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Viscosity based Detection Viscosity based Detection SystemSystem

Page 6: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Viscosity based Detection Viscosity based Detection SystemSystem

Page 7: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

NEW ANTICOAGULANTS

Katy Whelchel MT(ASCP)SH

Diagnostica Stago, Inc. Technical Support Specialist

February 23, 2006

Page 8: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Maintain hemostatic balance the body must maintain a fluid

equilibrium need to maintain balance between

bleeding & clotting

vessels

Platelets“Coagulation”Proteins

Fibrinolysis/ Inhibitors

Page 9: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

ANTICOAGULANT THERAPY Decrease the risk of post-op

thrombosis Decrease the risk of thrombosis in

patients with risk factors Decrease the risk of spontaneous

abortions in patients with Anti-Phospholipid Syndrome (APS) - lupus anticoagulants

Page 10: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

STANDARD ANTICOAGULANTS HEPARIN (UFH) COUMADIN (warfarin)

Page 11: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

UFH – a few things to remember

Will affect PTT- how much depends dosing and your reagent system

Easily monitored (accurately!) with the Anti-Xa method

Can be used in patients with renal failure

HAS an antidote (protamine sulfate)

Page 12: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Coumadin –a few things to remember

Can be monitored by the PT/INR Can be given long term for high

risk patients Can be used in patients with renal

failure HAS an antidote (Vitamin K)

Page 13: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

St. Lucia Island flowers

Page 14: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

2 classes of NEW ANTICOAGULANTS Antithrombin Dependant

LMWH – Lovenox, Fragmin, Innohep (tinzaparin – has been used on CAP surveys)

DANAPROID (not available in US) FONDAPARINUX (Arixstra)

Direct Thrombin Inhibitors HIRUDEN – LEPIRUDEN (Refludan) ARGATROBAN (Novastan) Bivalirudin Ximelagatran- the “new” coumadin

Page 15: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Why do we care about these new anticoagulants??

They are advertised

as “no monitoringneeded”!

Page 16: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Why do we care about these new anticoagulants?? They can and DO interfere with our

current coagulation tests Can you say how much of this new drug

is in the patient’s system? What do you do for these patients?

Patient is bleeding Patient is clotting – despite therapy Pre-op assessment? PT and PTT may or may not be “normal”

Page 17: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Why do we care about these new anticoagulants??

Special patient populations need special consideration: Pregnancy Renal dysfunction Liver dysfunction Anorexic or morbidly obese patients

Page 18: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Heparins UFH work on the activated factors LMWHs work where the extrinsic

and intrinsic factors come together with Factor Xa

Both use the patient’s ATIII to work

Page 19: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Coag Cascade

Page 20: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

LMWH Action

Page 21: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

LMWH HEPARINS LMWH – better bioavalibility than UFH

Created from UFH Since it’s a smaller molecule it can be

administered as a subcutaneous injection – given in fixed doses for MOST patients

Therapeutic Ranges: 0.5 – 1.1 (2 injections/day) 1.0 – 2.0 (1 injection/ day)

Timing of specimens - peak at about 4 hours after sub Q injection

Page 22: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Heparin Family picture

Page 23: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

LMWH HEPARIN Doesn’t change the APTT (much) –

an increased APTT may signify an overdose of LMWH or some other influence on the APTT (platelet antibodies)

Difficult to reverse with protamine sulfate (antidote for UFH)

Cleared through the kidneys

Page 24: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

LMWH HEPARIN LMWH available in the US:

Enoxaparin (Lovenox): prevent DVT/PE around surgery, treat DVT/PE, unstable angina

Dalteparin (Fragmin): prevent and treat DVT/PE, treat unstable angina

Tinzaparin(Innohep): treat DVT/PE

Page 25: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Who should be monitored for LMWH?

Patients with kidney problems (need to check creatinine clearance)

Patients that are obese or have a very low body weight

Children, burn patients

Page 26: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

How should LMWH be monitored?

Monitor with an anti-Xa method, using LMWH calibrators and controls.

Samples should be drawn 4 hours after dosing.

Page 27: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Marigot Bay, St. Lucia

Page 28: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Danaproid, Fonduparinux

Page 29: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

DANAPROID (not available in the US)

Mixture of heparinoids Usually given to HIT patients Works through antithrombin to inhibit

factor Xa (little effect on other factors) Administered twice a day – IV or Sub Q Therapeutic ranges – IV=0.5 – 0.8 Sub

Q= 0.13-0.35 Monitored by anti-Xa (like LMWH) –

using danaproid as the calibrator.

Page 30: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Danaproid (cont’d) It may prolong the PTT,as well as

affect the PT, TT and ACT. Used successfully in HIT – however,

platelet count should be monitored.

No agent that will reverse the effects of the drug.

Page 31: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

FONDAPARINUX (Arixtra) Synthetic pentasaccharide – accelerates

the binding of AT to Xa – the “ultimate LMWH”

Pure anti-Xa effect Commonly used to prevent VTE in

orthopedic surgery Administered Sub Q Half-life of 13 – 15 hours, so only 1 dose

per day. Excreted through kidney (check

creatinine clearance…..)

Page 32: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Fondaparinux (cont’d) PT and PTT are relatively insensitive to

this drug, but may be slightly prolonged. Low bleeding incidence. Has not been shown to cause HIT No direct inhibitor for Arixtra which can

reverse it’s anticoagulant effect. May be monitored by an Anti-Xa method

using the drug as a calibrator.

Page 33: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Fondaparinux (cont’d) Remember – there is no antidote.

So if the patient has too much “on board”, the PT and PTT may be normal, but they may still be bleeding…….can use Factor VIIa concentrate (novoseven) or activated prothrombin concentrates to reverse effect.

Page 34: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Ship: The Brig Unicorn

Page 35: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

DIRECT THROMBIN INHIBITORS Hirudin – Lepirudin (Refludan)

Hirudin: Medicinal Leech Refludan: recombinant polypeptide with

same action Agatroban Bivalirudin (Angiomax)

Do not cause thrombocytopenia; used successfully with HIT

Directly blocks Thrombin Administered by IV or Sub Q REQUIRES MONITORING

Page 36: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Direct Thrombin Inhibitors

Page 37: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

DIRECT THROMBIN INHIBITORS These drugs have a very short half

life. Agatroban cleared by the liver Lepirudin is cleared by the kidneys. Bivalirudin is cleared by the

kidneys Have to be aware of these factors

with the patient!

Page 38: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

ARGATROBAN Derivative of amino acid arginine Directly binds to Thrombin Metabolized by the liver, and excreted

through the kidney – so can be an alternate for patients with renal disease.

Must be monitored by APTT (can also be monitored by the ACT). Therapeutic range is 1.5-3.0 x Baseline APTT.

Page 39: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

REFLUDAN - Lepirudin APTT – IV=1.5 – 3.0 x patient baseline Sub Q= 2.2 – 2.7 X baseline APTT

(specimen drawn 3 hours after administration) HOWEVER, APTT reagents vary in their

sensitivity to Refludin ECARIN CLOTTING TIME (used in some

facilities) CHROMOGENIC ASSAY BASED ON THROMBIN

INHIBITION (developed for research only at this point) – most accurate assay

Page 40: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

DIRECT THROMBIN INHIBITORS These drugs will affect the PT/INR – since they

work at the bottom of the cascade Lepirudin: recommend stopping drug once

INR>2.0 Agatroban: recommend stopping drug once

INR>4.0 Levels are PT reagent dependent!! Literature

says that reagents with a lower ISI have less variability in reactivity. Higher ISI reagents have greater variablity in response.

Will affect results if patient is also on Coumadin!

Page 41: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

DIRECT THROMBIN INHIBITORS Since these drugs affect the PT/INR

system – and since they have a very short half-life – the good news is that if they are discontinued for a couple of hours, the PT should return to normal.

The bad news is that the kidneys and liver have to be working for this to happen.

Page 42: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Bivalirudin Approved for use in the cardiac

cath lab Bivalent thrombin inhibitor Short half-life (20 -30 min) Exclude patients with creatinine

>3.0

Page 43: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Live Volcano, St. Lucia

Page 44: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

DIRECT THROMBIN INHIBITORS Ximelagatran – the “new Coumadin”

Oral tablet Direct thrombin inhibitor Converts to melagatran in the stomach Cleared by kidneys Irreversible – factor VII concentrate

recommended for severe hemorrhage

Page 45: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

DIRECT THROMBIN INHIBITORSXimelagatran – the “new Coumadin” (cont’d) it’s supposed to work better than our

current LMWHs in preventing DVTs in people who have had hip surgery

Theoretically: NO MONITORING! It doesn’t matter how old you are, how much you weigh, etc. it is supposed to be safe…..however it causes liver damage in 6-10% of patients who take it long term. And remember – it is cleared by the kidneys.

Page 46: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

DIRECT THROMBIN INHIBITORSXimelagatran – the “new Coumadin” (cont’d) Not approved by FDA – yet. If you were going to monitor Ximelagatran,

remember it is a thrombin inhibitor – so you’d have to monitor the APTT – NOT a PT even though it is the “new Coumadin”!!

APTT’s response again will be variable depending on reagent system.

Page 47: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

DIRECT THROMBIN INHIBITORS

Ximelagatran – the “new Coumadin” (cont’d)

So – for the time being, we’ll still be doing PT/INR for coumadin therapy.

Page 48: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

Summary Many of these anticoagulants are currently in

use. They may affect routine and specialty

coagulation tests – remember where they affect the cascade!

If abnormal results are obtained, and not expected – ask what drugs the patient is on.

Remember many will act differently if the patient has renal or hepatic impairment.

The “tried and true” may still be the easiest to use if monitored correctly.

Page 49: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

St. Lucia Sunset

Page 50: Mechanical Clot Detection Stago’s Viscosity-based Clot Detection System

The end.