medc product overview - cooper medc€¦ · medc product overview world class manufacturers of...

52
MEDC Product Overview World class manufacturers of alarm, signalling and notification products for use in hazardous and industrial areas

Upload: tranmien

Post on 21-Aug-2018

230 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

MEDC Product OverviewWorld class manufacturers of alarm, signalling and notification products for use in hazardous and industrial areas

Page 2: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

In today’s intensely competitive marketplace, proven reliability and expertise combine with functionality to drive the ultimate purchasing decision. When you are working on a multi-million dollar construction project, you need a partner that can support you with tried-and-tested products as well as a full service and support package from initial system definition through to design and service. Cooper MEDC is dedicated to maximising both personnel and equipment safety by offering a comprehensive range of innovative notification solutions designed for potentially explosive atmospheres and harsh industrial and marine environments.

Proven solutions for harsh and hazardous environmentsDesigners and manufacturers of alarm, signal, control and communications equipment since 1975, Cooper MEDC has developed a range of products specifically designed for harsh environmental conditions and where there is a risk of explosion due to the presence of flammable atmospheres both offshore and onshore. The extensive range of manual, visual, audible alarms and loudspeakers has been developed in close collaboration with customers to deliver the best combination of performance and safety. Through its vast global presence, technical sales force and engineering experts, Cooper MEDC meets the demanding standards of a multitude of industries including: oil, gas, petrochemical, marine and mining.

Technical solutions and superior performanceCooper MEDC has pioneered the use of glass reinforced polyester (GRP) in explosion-proof products to deliver solutions with reduced maintenance, extended lifetime and lower cost of ownership. Since 1975, the oil and gas industry has counted on Cooper MEDC for the most reliable and highly respected alarms and loudspeakers in the industry. Extensive quality certifications include ATEX, CQST, UL, ULC, CSA, GOST R, GOST K, IECEx and Inmetro and demonstrate our commitment to maintaining our leadership position in the market.

Thousands of Products, Hundreds of Solutions, One CooperWithin Cooper Industries’ Safety division, Cooper MEDC’s noti f ication equipment is part of a comprehensive portfolio of solutions which also includes emergency lighting, security and fire detection as well as lighting fixtures and electrical installation materials.

Cooper Safety specialises in products designed to save lives and protect property in the most demanding industrial, residential and commercial environments worldwide. The company’s high-quality brands have earned leadership positions in the markets we serve and that leadership is sustained through unparalleled sales support, market expertise and local availability. Cooper Safety is a division of Cooper Industries with manufacturing facilities in 23 countries and more than 25,000 people throughout the world.

Introduction

www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

Page 3: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

3

Manual Alarm Call Points6

Status Lights9

Beacon / Strobes12

Sounders / Horns20

Speakers27

Combination Units24

Detectors / Control / Distribution31

Heavy Duty Industrial / Marine35

North American Certified Products38

How to use this OverviewThis overview contains concise information on Cooper MEDC products for use in potentially explosive atmospheres, harsh industrial and marine environments.

To use this guide, refer to the product group of interest, read through the brief information and select the specific product for your application.

For more detailed information visit our website www.medc.com where a detailed datasheet can be downloaded. Or alternatively contact our sales offices in the UK and the USA for a full catalogue.

Page 4: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

4 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

This information is intended as a guide only and further expert guidance should be sought before placing into service, maintaining or repairing any item of equipment in a Potentially Explosive Atmosphere.Definition | Potentially Explosive Atmospheres exist where there is a risk of explosion due to mixtures of gas/air, vapour/air, dust/air or other flammable combinations. Where electrical equipment has to be used in these areas, it must be so designed and constructed such that it does not create sources of ignition capable of igniting these mixtures.

Area Classification | Process plants are divided into Zones (European and IEC method) or Divisions (North American method) according to the likelihood of a Potentially Explosive Atmosphere being present. Note: North American legislation now allows Zones to be used to classify areas, where this practice is used it follows the IEC Zone method.

ATEXAfter 1st July 2003, the ATEX directive came into force and is a mandatory requirement for all equipment intended for use in Potentially Explosive Atmospheres within the E.U. All relevant MEDC equipment is covered by the date it comes into force and many are already certified. It should be noted also that MECHANICAL equipment is covered by the ATEX directive so for the first time items such as gearboxes will have to carry ATEX certification.

TemperatureTo guard against hot surfaces igniting gases, all electrical equipment intended for use in Potentially Explosive Atmospheres is classified according to the maximum surface temperature it will reach in service (normally based on a surrounding ambient temperature of 40°C (102°F).

Temperature Classification

T1 T1 450° CT2 T2 300° C T2A 280° C T2B 260° C T2C 230° C T2D 215° CT3 T3 200° C T3A 180° C T3B 165° C T3C 160° CT4 T4 135° C T4A 120° CT5 T5 100° CT6 T6 85° C

Maximum Surface Temperature European/I.E.C. North American

Gas Groups, Dusts and FibresThere are two main gas groups, Group I – Mining only and Group II – Surface Industries.

These categories are used in European and I.E.C. groupings.

Group I is concerned only with underground mining where methane and coal dust are present.

Group II gases occurring in surface industries, are sub-grouped according to their volatility. This enables electrical equipment to be designed to less onerous tolerances if it is to be used with the least volatile gases.

Methane I -Acetylene IIC AHydrogen IIC BEthylene IIB CPropane IIA DMetal dust - ECoal dust - FGrain dust - G

North American Gas Group

Typical gas/ material

European/I.E.C. Gas Group

European & IEC Classification Definition of zone or division North American Classification

Zone 0 (gases) An area in which an explosive mixture is Class I Division 1 (gases) Zone 20 (dusts) continuously present or present for long periods Class II Division 1 (dusts)

Zone 1 (gases) An area in which an explosive mixture is Class I Division 1 (gases) Zone 21 (dusts) likely to occur in normal operation Class II Division 1 (dusts)

Zone 2 (gases) An area in which an explosive mixture is not Class I Division 2 (gases) Zone 22 (dusts) likely to occur in normal operation and if it Class II Division 2 (dusts) occurs it will exist only for a short time Class III Division 1 (fibres) Class III Division 2 (fibres)

The equipment coding will be as the current practice plus an additional code as follows:ExII2GD i.e.Ex – Explosionproof in accordance with ATEX.II – Group II surface industries2 – Category 2 equipment (suitable for use in Zone 1) note: Category 1 is suitable for Zone 0. Category 3 is suitable for Zone 2.G – suitable for atmospheres containing gasD – suitable for atmospheres containing dustEquipment will be CE marked when certified to ATEX.For more information about hazardous areas, download guide from www.medc.com.

Hazardous Area Guide

Page 5: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

5

International Europe U.S.A.

General Recommendations IEC60079-14 EN60079-14 N.E.C. Chapter 5Classification of Hazardous Areas IEC60079-10 EN60079-10 N.E.C. Chapter 5Inspection and Maintenance of Electrical Equipment IEC60079-17 EN60079-17 -Requirements for Flameproof Enclosures IEC60079-14 EN60079-14 N.E.C. Chapter 5Requirements for Intrinsically Safe Equipment IEC60079-14 EN60079-14 N.E.C. Chapter 5Requirements for Increased Safety Equipment IEC60079-14 EN60079-14 N.E.C. Chapter 5Requirements for Purged and Pressurised Equipment IEC60079-14 EN60079-14 N.E.C. Chapter 5Requirements for Non-Sparking Equipment IEC60079-14 EN60079-14 -

Selection, Installation and Maintenance of Electrical Equipment Intended for use in Potentially Explosive Atmospheres

European IEC USA Area of use Area of use Area of use Designation Designation Designation

Standard Standard Standard

Flameproof Enclosure – An enclosure used to house electrical Zones 1 & 2 Zones 1 & 2 Class Iequipment, which when subjected to an internal explosion will not Divisions 1 & 2ignite a surrounding explosive atmosphere. EExd Exd – EN60079-1 IEC60079-1 UL1203

Intrinsic Safety – A technique whereby electrical energy is limited Zones 0, 1 & 2 Zones 1 & 2 Class Isuch that any sparks or heat generated by electrical equipment is Divisions 1 & 2sufficiently low as to not ignite an explosive atmosphere. EExi Exi – EN60079-11 IEC60079-11 UL913

Increased Safety – This equipment is so designed as to eliminate Zones 1 & 2 Zones 1 & 2 –sparks and hot surfaces capable of igniting an explosive EExe Exi –atmosphere. EN60079-7 IEC60079-7 –

Purged and Pressurised – Electrical equipment is housed in an Zones 1 & 2 Zones 1 & 2 Class Ienclosure which is initially purged to remove any explosive mixture, Divisions 1 & 2then pressurised to prevent ingress of the surrounding atmosphere EExp Exp –prior to energisation. EN60079-2 IEC60079-2 NFPA496

Encapsulation – A method of exclusion of the explosive atmosphere Zones 1 & 2 Zone 1 & 2 –by fully encapsulating the electrical components in an approved EExm Exm –material. EN60079-18 IEC60079-18 –

Oil Immersion – The electrical components are immersed in oil, Zone 1 & 2 Zones 1 & 2 Class Ithus excluding the explosive atmosphere from any sparks or hot Division 2surfaces. EExo Exo – EN50015 IEC60079-6 UL698

Powder Filling – Equipment is surrounded with a fine powder, such as Zones 1 & 2 Zones 1 & 2 – quartz, which does not allow the surrounding atmosphere to come EExq Exq –into contact with any sparks or hot surfaces. EN50017 IEC60079-5 –

Non-sparking – Sparking contacts are sealed against ingress of the Zone 2 Zone 2 –surrounding atmosphere, hot surfaces are eliminated. EExn Exn – EN60079-15 IEC60079-15 –

Different techniques are used to prevent electrical equipment from igniting explosive atmospheres. There are restrictions on where these different types of equipment can be used as follows:

Types of Electrical Equipment Suitable for use in Potentially Explosive Atmospheres

International and national standards are published giving details of requirements for the safe use of Electrical Equipment in Potentially Explosive Atmospheres as follows:

Cooper MEDC advise that all Explosion-proof electrical equipment is maintained, by suitably trained personnel, in accordance with the Manufacturers’ recommendations.

Any spare parts used should be purch ased from the original Manufacturer and repairs should be carried out by the Manufacturer or under his supervision, in order that the item remains in conformance with the certification documents.

Page 6: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

6 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

Manual Alarm Call PointsCooper MEDC offer a range of manual alarm call points, in various materials covering push button and break glass versions.

Manual alarm call points are designed for the purpose of raising an alarm manually once verification of a fire or emergency condition exists, by operating the push button or break glass the alarm signal can be raised.

There are options for the inclusion of LED status indicators and addressable boards to give the unit an individually recognised location (or address) within the system. These manual call points are designed to meet European or North American industrial and fire application standards.

Page 7: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

7

Explosionproof & Weatherproof – Break Glass Call Point | BG ATEX, UL, CSA, GOST ‘R’ & ‘K’, CQST, Inmetro, IECExATEX Ex II 1GD, EExia IIC T4ATEX Ex II 2GD, EExed(m) IIC T4 (T6)Model dependant - refer to datasheet-40°C to +50°C (EExia)-20°C to +50°C (EExed)IP66 & 67Corrosion-free GRPUp to 4 x 20mm or 16mm (NPT for UL)1.2kg (varies with model)Body colour, LED, lift flap, series & EOL resistors, diodes, earth continuity, terminals, certification, tag & duty labels.

CertificationIntrinsically SafeIncreased Safety

Area Classification

Certified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

Explosionproof & Weatherproof – Break Glass Call Point | BG2

CertificationIntrinsically SafeIncreased Safety

Area Classification

Certified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEXATEX Ex II 1GD, EExia IIC T4ATEX Ex II 2GD, EExed(m) IICT4 (T6)Model dependant - refer to datasheet-40°C to +50°C (EExia)-20°C to +50°C (EExed)IP66 & 67Corrosion-free GRP2 x 20mm1.2kgLift flap, series & EOL resistors

Explosionproof & Weatherproof – Break Glass Call Point | BG3 ATEX, CQSTATEX Ex II 1G, EExia IIC T4Model dependant - refer to datasheet-55°C to +55°C (EExia)IP66 & 67Corrosion-free GRP2 x 20mm0.5kgBody colour, LED, lift flap, series & EOL resistors, tag & duty labels.

CertificationIntrinsically Safe

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

Manual Alarm Call Points

Certification Type Ordering Code ATEX Ex II 1GD Intrinsically Safe PX800002 ATEX Ex II 2GD Increased Safety PX800003

Standard Product ConfigurationStandard models have 2 x 20mm bottom entries, red painted GRP, single switch glass label ‘Break Glass Press Here’.

Standard models.Available ex-stock.

Certification Type Ordering Code ATEX Ex II 1GD Intrinsically Safe PX800005 ATEX Ex II 2GD Increased Safety PX800004

Standard models.Available ex-stock.

Standard Product ConfigurationStandard models have 2 x 20mm bottom entries, painted red GRP, single switch glass label ‘Break Glass Press Here’.

Standard models. Available ex-stock.

Standard Product ConfigurationStandard models are surface mount version, have 2 x 20mm bottom entries, painted red GRP, single switch glass label ‘Break Glass Press Here’, duty label ‘Burning House’

Certification Type Ordering Code ATEX Ex II 1G Intrinsically Safe PX800007 – Weatherproof PX800006

Page 8: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

8 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

SM87 BG | Break Glass Call Point – Explosionproof & Weatherproof

CertificationIntrinsically Safe

FlameproofArea Classification

Certified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEX, CSA, GOST ‘R’ & ‘K', CQST, InmetroATEX Ex II 1G, EExia IIC T4ATEX Ex II 2G, EExd IIC T6Zone 0, Zone 1 and Zone 2 use*-55°C to +70°C-20°C to +55°C (LED)IP66 & 67Stainless Steel or AlloyUp to 4 x 20mm or 25mm3.8kg (Steel) 2.5kg (Alloy)Body colour, lift flap, LED, resistor, diode, 3 & 4 pole changeover switch, certification, tag & duty labels.

PB | Push Button Call Point – Explosionproof & Weatherproof

CertificationIntrinsically SafeIncreased Safety

Area Classification

Certified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEX, UL, CSA, GOST ‘R’ & ‘K’, CQST, Inmetro, IECExATEX Ex II 1GD, EExia IIC T4ATEX Ex II 2GD, EExed(m) IIC T4 (T6)Model dependant - refer to datasheet-40°C to +70°C (EExia)-20°C to +50°C (EExed)IP66 & 67Corrosion-free GRPUp to 4 x 20mm or 16mm (NPT for UL)1.2kgBody colour, LED, series & EOL resistors, diode, earth continuity (Not UL), turn & push, self reset, tag & duty labels.

SM87 PB | Push Button Call Point – Explosionproof & Weatherproof

CertificationIntrinsically Safe

FlameproofArea Classification

Certified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEX, UL, CSA, GOST ‘R’ & ‘K’, CQST, InmetroATEX Ex II 1G, EExia IIC T4ATEX Ex II 2G,EExd IIC T6Zone 0, Zone 1 and Zone 2 use*-55°C to +70°C-20°C to +55°C (LED)IP66 & 67Stainless Steel or AlloyUp to 4 x 20mm or 25mm (NPT for UL)3.8kg (Steel) 2.5kg (Alloy)Body colour, LED, resistor, diode,3 & 4 pole changeover switch, certification, tag & duty labels.

Manual Alarm Call Points

*Depending on version.

*Depending on version.

Page 9: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

9

Status LightsCooper MEDC offer a range of Status Lights designed for potentially explosive atmospheres and harsh environmental conditions.

Status lights are commonly found in oil, gas, petrochemical and other hazardous areas where multicoloured lamp combinations are used to identify the safety status of specific zones.

Page 10: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

10 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

SM87 SL | Xenon, Filament, Fluorescent & LED Status Lamps – Explosionproof & Weatherproof

ATEX, GOST ‘R’ & ‘K’, CQST, Inmetro, CSAATEX Ex II 2G,EExd IIC T4 (LED/FiI)ATEX Ex II 2G,EExd IIC T6 (Xe/Fl)Zone 1 and Zone 2 use.

-20°C to +55°C (LED/FI)-55°C to +70°C* (Xe/Fil)IP66 & 67Stainless Steel or AlloyUp to 3 x 20mm or 25mmUp to 4Body & lens colour, certification, tag & duty labels.*Model dependant, refer to data sheet.

Certification

Flameproof

Area Classification

Certified Ambient Temperature

Ingress ProtectionMaterialEntries

No. of Ways

Options

SL5 | Xenon, Filament & LED Status Lights – Explosionproof & Weatherproof

CertificationIncreased Safety

Area Classification

Certified Ambient Temperature

Ingress ProtectionMaterialEntries

No. of WaysOptions

SL15 Range | Status Lights – Explosionproof &Weatherproof

ATEX, CQSTATEX Ex II 2G,EExe(m) II T3/T4Zone 1 and Zone 2 use.-40°C to +55°C (Xe/FiI)-40°C to +45°C (LED)IP66 & 67Corrosion-free GRPUp to 2 x 16mm or 20mm or 1 x 25mm or 32mmUp to 5Body & lens colour, certification, tag & duty labels.

CertificationArea Classification

Certified Ambient TemperatureIngress Protection

MaterialEntries

No. of Ways

Options

ATEX, and IEC Ex Approved, ULModel dependant - refer to datasheet-55°C to +70°CIP66 & 67Corrosion-free GRPUp to 2 x ½" or 2 x ¾" entries. ATEX has M20 or M25.Up to 4Various flash rates available for xenon units. Various lens colours. Optional cast or wire lens guard.

UL Version

Status Lights

Page 11: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

11

Status Lamps can also be configured using the high intensity XB4 range.

ATEX, UL, Inmetro, CQSTATEX Ex II 2GD, EExd IIB T5/T6Zone 1 and Zone 2 use.-55°C to +70°CIP66 & 67Corrosion-free GRP1 x 20mm (NPT for UL)Up to 5Body & lens colour, tag & duty labels.

Explosionproof & Weatherproof– Xenon, Filament & Flourescent Status Lamps | XB11SL

CertificationFlameproof

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntries

No. of WaysOptions

Explosionproof & Weatherproof – Xenon, Filament & Flourescent Status Lamp | XB12SL

CertificationFlameproof

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntries

No. of WaysOptions

ATEX, UL, Inmetro, GOST, CQSTATEX Ex II 2G, EExd IIB T4/T5Model dependant - refer to datasheet-55°C to +70°C IP66 & 67Corrosion-free GRP1 x 20mm (NPT forUL)Up to 5Body & lens colour, tag & duty labels.

Page 12: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

12 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

Beacons / StrobesCooper MEDC offer a range of beacons including flashing, steady-state indicators and rotating units. These may be used to warn of potential hazards or indicate the status of plant items, gas and oil leaks, evacuation alerts and many more.

The signals may operate as stand-alone units or be incorporated into a wider system, such as a fire panel. Within this section there is a wide variety of output values and lens colours.

© BP p.l.c

Page 13: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

13

ATEX, UL, CSA, GOST ‘R’ & ‘K’, CQST, InmetroATEX Ex II 2GD, EExd(e) IIC T4 &T6Model dependant - refer to datasheet-55°C to +70°C (EExd)IP66 & 67Stainless Steel or AlloyUp to 4 x 20mm or 25mm (NPT for UL)3.8kg (Steel) or 2kg (Alloy)Body & lens colour, EOL resistor, tel. & relay initiate, lens guard, tag or duty labels, flash rate, high temp. version (-40°C to +85°C) available, voltages 24-48V d.c., 110-254V a.c.

ATEX, UL, CQST, SAA, Inmetro, GOST ‘R’ & ‘K’, IECExATEX Ex II 2GD, EExd IIB T4, T5 & T6Zone 1 and Zone 2 use.-55°C to +70°C IP66 & 67Corrosion-free GRP2 x 20mm (NPT for UL)2.5kgBody & lens colour, mounting, tel. initiate, lens guard, flash rate, earth continuity, voltages 24V d.c., 110V a.c., 240 V a.c.

ATEX, Inmetro, IECExATEX Ex II 2G, EExd IIC T5/T6Zone 1 and Zone 2 use.-55°C to +55°CIP66 & 67Corrosion-free GRP1 x 20mm or PG13.51.6kgBody & lens colour, tag or duty labels, voltages, flash rate, 24-48V d.c., 110-254V a.c.

CertificationFlameproof

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

CertificationFlameproof

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

CertificationFlameproof

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

Beacons / Strobes

Explosionproof & Weatherproof – 5 Joule Flashing Xenon | SM87 HXB

Explosionproof & Weatherproof – 5 Joule Flashing Xenon | XB11

Explosionproof & Weatherproof – 5 Joule Flashing Xenon | XB9

Certification Voltage Lens Colour Ordering Code ATEX Ex II 2G 24V d.c. Red PX813005 ATEX Ex II 2G 24V d.c. Amber PX813006 ATEX Ex II 2G 240V a.c. Red PX813007 ATEX Ex II 2G 240V a.c. Amber PX813008

Standard Product ConfigurationStandard models are in alloy, red body, no tag or duty labels, 2 x M20 entries, 60 flashes per minute.

Standard models. Available ex-stock.

Standard models. Available ex-stock.

Standard models. Available ex-stock.

Certification Voltage Lens Colour Ordering Code ATEX Ex II 2GD 24V d.c. Red PX811101 ATEX Ex II 2GD 24V d.c. Amber PX811102 ATEX Ex II 2GD 240V a.c. Red PX811103 ATEX Ex II 2GD 240V a.c. Amber PX811104

Standard Product ConfigurationStandard models are in GRP, natural black body, no tag or duty labels, 2 x M20 entries, 60 flashes per minute.

Standard Product ConfigurationStandard model has natural black body, no tag or duty labels, 60 flashes per minute, lens guard, 3m cable & tail.

Certification Voltage Lens Colour Ordering Code ATEX Ex II 2G 24V d.c. Red PX819105 ATEX Ex II 2G 24V d.c. Amber PX819106 ATEX Ex II 2G 240V a.c. Red PX819107 ATEX Ex II 2G 240V a.c. Amber PX819108

Page 14: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

14 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

UL (1971 compliant)Class I, Div 2, Groups A-DClass II, Div 2, Groups F & GModel dependant - refer to datasheetCertified Ambient Temperature -55°C to +70°CIP66 & 67Corrosion-free GRP1 x ¾" NPT1kgBody & lens colour, lens guard, tag & duty labels, relay initiate, flash rate, voltages 12-48V d.c., 110-254V a.c.

XB10 | 10 & 15 Joule Flashing Xenon – Explosionproof & Weatherproof

ATEX, GOST ‘R’, Inmetro, IECExATEX Ex II 2G, EExd(e) IIB T4Zone 1 and Zone 2 use.*-55°C to +55°C 10 Joule *-55°C to +40°C 15 JouleIP66 & 67Corrosion-free GRPUp to 3 x 20mm or 2 x PG13.5EExd 2.8kg EExde 3.6kgBody & lens colour, tel. initiate, earth continuity, flash rate, terminal chamber, voltages 24-48V d.c., 110-254V a.c.

*EExd version only, see data sheet for more information.

ATEX, UL, Inmetro, ULC, IECExATEX Ex II 2GD, EExd IIC T4, T5 & T6Zone 1 and Zone 2 use.-55°C to +70°CIP66 & 67Corrosion-free GRPUp to 3 x 20mm or 3 x 25mm (NPT for UL)2.6-3kgBody & lens colour, relay & telephone initiate, flash rate, voltages 12-48V d.c., 110-254V a.c.

CertificationFlameproof

Area Classification

Certified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

XB16 | 10 Joule Flashing Xenon – UL Hazardous & Ordinary Locations

Certification

Hazardous Locations

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

XB15 | 15 Joule Flashing Xenon – Explosionproof & Weatherproof

Direct Mount Pipe Mount UL only

CertificationFlameproof

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

Beacons / Strobes

Certification Voltage Lens Colour Ordering Code ATEX Ex II 2G 24V d.c. Red PX811050 ATEX Ex II 2G 24V d.c. Amber PX811051 ATEX Ex II 2G 240V a.c. Red PX811052 ATEX Ex II 2G 240V a.c. Amber PX811053

Standard Product ConfigurationStandard models are in natural black, 15 Joules, lens guard, no tag or duty labels, 2 x M20 entries, 60 flashes per minute.

Standard models. Available ex-stock.

Page 15: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

15

CertificationFlameproof

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

Explosionproof & Weatherproof – 21 Joule Flashing Xenon | XB4

CertificationFlameproof

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEX, UL, GOST ‘R’, SAA, InmetroATEX Ex II 2G, EExd(e) IIC T5Zone 1 and Zone 2 use.-55°C to +70°CIP66 & 67Stainless Steel or AlloyUp to 4 x 20mm or 25mm15-16kg (Steel), 6.6-7.6kg (Alloy)Body & lens colour, lens guard, tag & duty labels, terminal chamber, initiation options, flash rate, voltages 24-48V d.c., 110-254V a.c.

ATEX, UL, GOST ‘R’ & ‘K’, CQST, Inmetro, IECExATEX Ex II 2G, EExd IIB T4/T5Zone 1 and Zone 2 use.-55°C to +70°CIP66 & 67Corrosion-free GRP2 x 20mm (NPT for UL)7.0kgBody & lens colour, lens guard, tag & duty labels, telephone initiation, flash rate, mounting method, earth continuity, voltages 24V d.c., 110-240V a.c.

Explosionproof & Weatherproof – 21 Joule Flashing Xenon | XB12

ATEX GOST ‘R’ATEX Ex II 1G, EExia IIB/IIC T4Zones 0, 1, 2 & safe area use.-55°C to +60°CIP66 & 67Corrosion-free GRP body, Polycarbonate lensUp to 3 x 20mm via knockouts1.4kgBody & lens colour, certification, tag & duty labels, voltages 12-24V d.c.

CertificationIntrinsically Safe

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

Explosionproof & Weatherproof – 0.5 Joule Flashing Xenon | XB8

Standard models. Available ex-stock.

Standard models. Available ex-stock.

Standard models. Available ex-stock.

Certification Voltage Lens Colour Ordering Code ATEX Ex II 2G 24V d.c. Red PX814001 ATEX Ex II 2G 240V a.c. Red PX814002

Standard Product ConfigurationStandard model are red painted, alloy, no lens guard, 2 x M20 entries.

Standard Product ConfigurationStandard models are in natural black GRP, no lens guard, 2 x 20mm entries, 60 flashes per minute.

Certification Voltage Lens Colour Ordering Code ATEX EX II 2GD 24V d.c. Red PX812101 ATEX EX II 2GD 24V d.c. Amber PX812102 ATEX EX II 2GD 240V a.c. Red PX812103 ATEX EX II 2GD 240V a.c. Amber PX812104

Certification Voltage Lens Colour Ordering Code ATEX Ex II 1G 24V d.c. Clear PX818002

Standard Product ConfigurationStandard models have painted red body colour, no tag or duty labels, 60 flashes per minute.

Page 16: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

16 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

CertificationFlameproof

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEX, UL, Inmetro, GOST ‘R’ATEX Ex II 2GD, EExd IIB T4/T5Zone 1 and Zone 2 use.-20°C to +55°C (FB11)IP66 & 67Corrosion-free GRP2 x 20mm (NPT for UL)2.8kgBody & lens colour, lens guard, tag & duty labels, lamp wattage, unit fixing, earth continuity, mounting method, voltages 24-48V d.c., 110-254V a.c.

XB13 | 10 Joule Flashing Xenon – Weatherproof & Heavy Duty

Area ClassificationOperating Temperature

Ingress ProtectionMaterialEntriesWeight

Options

Weatherproof.-55°C to +70°CIP66 & 67Corrosion-free GRP body Polycarbonate lensUp to 3 x 20mm via knockouts1.1kgBody & lens colour, tag & duty labels, lens guard, telephone & relay initiate, single & dual flash mode, voltages 12 or 24V DC, 115 or 230V AC.

SM87 | LU1/LU3 10 Watt Steady Filament/Fluorescent – Explosionproof & Weatherproof

* Model dependent

ATEX, UL, CSA, CQST, Inmetro, GOST ‘R’ & ‘K’ATEX Ex II 2GD, EExd(e) IIC T4/T6Zone 1 and Zone 2 use.*-55°C to +55°C IP66 & 67Stainless Steel or AlloyUp to 3 x 20mm or 25mm (NPT for UL)2.5 - 3.8kgBody & lens colour, lens guard, tag or duty labels, terminal chamber, voltages 24-48V d.c., 110-254V a.c.

CertificationFlameproof

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

FB11 & FL11 | 10 Watt Steady Filament & Fluorescent – Explosionproof & Weatherproof

Voltage Lens Colour Ordering Code 24V d.c. Red PX813101 24V d.c. Amber PX813102 230V a.c. Red PX813103

Standard Product ConfigurationStandard models are in painted red body colour, no tag or duty labels, no lens guard, 3 x 20mm entries via knockouts, 60 flashes per minute (single flash mode), dual & single flash modes.

Standard models. Available ex-stock.

Beacons / Strobes

Page 17: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

17

CertificationArea Classification

Flameproof

Certified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEX, UL, GOST ‘R’, InmetroZone 1 and Zone 2 use.ATEX Ex II 2G, EExd(e) IIC T3/T6-55°C to +55°C (FB4 EExd)-50°C to +55°C (FB4 EExde)-20°C to +55°C (FL4)IP66 & 67Stainless Steel or AlloyUp to 4 x 20mm or 25mm14.9-17.3kg (Steel), 6.5 - 8.9kg (Alloy)Body & lens colour, lens guard, tag & duty labels, lamp wattage, relay initiate or terminal chamber, voltages 24-48V d.c., 110V d.c., 110-254V a.c.

Explosionproof & Weatherproof – 100 Watt Steady Filament & 39 Watt Fluorescent | FB4 & FL4

CertificationFlameproof

Area Classification

Certified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEX, UL, GOST ‘R’, InmetroATEX Ex II 2G, EExd IIB T4/T5Zone 1 and Zone 2 use.-55°C to +55°C (FB12)-20°C to +55°C (FL12)IP66 & 67Corrosion-free GRP2 x 20mm (NPT for UL)7.2 - 7.6kgBody & lens colour, lens guard, tag & duty labels, lamp wattage, unit fixing, earth continuity, mounting method, voltages 24-48V d.c., 110-254V a.c.

Explosionproof & Weatherproof – 100 Watt Steady Filament & 39 Watt Fluorescent | FB12 & FL12

CertificationFlameproof

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEX, UL, Inmetro, GOST ‘R’, IECExATEX Ex II 2GD, AExd IIC T3/T4Zone 1 and Zone 2 use.-55°C to +70°CIP66 & 67Corrosion-free GRP2 x 20mm (NPT for UL)2.6 Kg (Pipe Mount) 3.0 Kg (Direct Mount)Body & lens colour, lens guard, tag & duty labels, lamp wattage, unit fixing, mounting method, voltages 24-48V d.c., 110-254V a.c.

Explosionproof & Weatherproof – 60 Watt Steady Filament | FB15

Pipe MountDirect Mount

Page 18: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

18 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

Certification

FlameproofArea Classification

Certified Ambient TemperatureIngress Protection

MaterialEntriesWeight

Options

ATEX, UL, GOST, Inmetro, CSA, CQST, GOST ‘R’ & ‘K’ATEX Ex II 2GD, EExd(e) IIC T6Zone 1 and Zone 2 use.-20°C to +40°CIP66 & 67Stainless Steel or AlloyUp to 3 x 20mm or 25mm2.5 - 4.5kgBody & lens colour, lens guard, tel & relay initiate, EOL resistor, terminal chamber, voltages 24-48V d.c..

CertificationFlameproof

Area Classification

Certified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEXATEX Ex II 2G, EExd(e) IIB T4/T6Zone 1 use.-20°C to +55°C (TH5)-20°C to +40°C (XB5)IP66, 67 & 68AlloyUp to 4 x 20mm or 25mm – Exe only14.6 - 15.9kgBody & lens colour, lens guard, tag label, terminal chamber, rotational speed, voltages *12-48V d.c., 110-254V a.c.

*See datasheet for voltage option for TH5.

FB5 & FL5 | 200 Watt Steady Filament & 52 Watt Steady Fluorescent – Explosionproof & Weatherproof

CertificationFlameproof

Area Classification

Certified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEXATEX Ex II 2G, EExd(e) IIB T3/T4Zone 1 and Zone 2 use.-20°C to +30°C (FB5)-20°C to +50°C (FL5)IP66, 67 & 68Stainless Steel or AlloyUp to 4 x 20mm or 25mm11.6 - 14.3kgBody colour, lens guard, mounting method,voltages 220-254V a.c.

SM87 LED | Up to 192 Cd Steady or Flashing LED (Selectable) – Explosionproof & Weatherproof

XB5 & TH5 | 5 Joule Sequenced & 70 Watt Rotating – Explosionproof & Weatherproof

Energy efficient LED product

Beacons / Strobes

Page 19: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

19

CertificationFlameproof

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEX, CSA (HS5 only)ATEX Ex II 2G, EExd(e) IIB T3/T4Zone 1 and Zone 2 use.-20°C to +40°CIP66, 67 & 68Stainless Steel or AlloyUp to 4 x 20mm or 25mm12.9 - 14.0kgBody colour, lens guard, tag label, terminal chamber, mounting method, voltages 220-254V a.c.

Explosionproof & Weatherproof – 70 Watt Sodium/80 Watt Mercury Fluorescent | HS5 & MF5

Explosionproof & Weatherproof – 55 Watt/70 Watt Rotating Beacon | TH12

CertificationFlameproof

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEX, GOST ‘R’, InmetroATEX Ex II 2G, EExd IIB T4/T5Zone 1 and Zone 2 use.-55°C to +70°C T4IP66 & 67Corrosion-free GRP2 x 20mm7.6kgBody & lens colour, lens guard, tag & duty labels, flash rate, mounting method, earth continuity, volt-ages 24V d.c. 110-240V a.c.

Page 20: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

20 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

Sounders / HornsCooper MEDC Sounders and Horns feature a variety of tone settings, voice messaging or traditional bells. Sounders and Horns are used to warn of potentially dangerous situations or to relay instructions.

In addition the alarms may operate as stand-alone units or be incorporated into a hazard warning system. A wide variety of sound output levels and other options are also available. The Sounders and Horns output in dB(A) is measured to European standards at 1 metre.

Page 21: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

21

CertificationFlameproof

Area Classification

Certified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

No. of Tones

Options

Explosionproof & Weatherproof –118dB(A) Sounder | DB3 ATEX, UL, GOST ‘R’ & ‘K’, CQST, SAA, InmetroATEX Ex II 2GD, EExd(e) IIC T5Zone 1, Zone 2 and non-Ex use.-20°C to +70°C (standard)-55°C to +55°C (low temp unit)IP66 & 67Corrosion-free GRPUp to 2 x 20mm5.0kg27 user selectable tones and 5 optional programmable spaces.Body colour, tag & duty labels, two stage alarm (DB3P), low temperature version available, EOL resistor, certification, terminal chamber voltages 12-48V d.c., 110V-254V a.c.

Explosionproof & Weatherproof – 113dB(A) Sounder | DB1CertificationFlameproof

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEX, UL, GOST ‘R’, SAA, Inmetro, IECExATEX Ex II 2G, EExd IIB T3Zone 1 and Zone 2 use.-20°C to +70°CIP66Stainless steel or alloyUp to 3 x 20mm or 25mm*3.5-12.7kg Body colour, tag & duty labels, two stage (DB1P) alarms, high output (DB1HP), tel, relay or remote initiate, EOL resistor, certification, voltages 12-48V d.c., 110V a.c., 240V a.c.

Explosionproof & Weatherproof – 110dB(A) Voice Sounder | DB3VCertificationFlameproof

Area Classification

Certified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Speech Duration

Options

ATEX, UL, GOST ‘R’ & ‘K’, CQST, SAA, InmetroATEX Ex II 2GD, EExd(e) IIC T5Zone 1, Zone 2 and non-Ex use.-20°C to +55°C (standard)-55°C to +55°C (low temp unit)IP66 & 67Corrosion-free GRPUp to 2 x 20mm5.0kgUp to 20 seconds repeatableBody colour, tag & duty labels, low temperature version available, EOL resistor, record feature, cer-tification, terminal chamber, ‘mechanical bell’ sound version, voltages 12-48V d.c.

*Model dependent

Sounders / Horns

Certification Ordering Code ATEX Ex II 2G PX801001

Standard Product ConfigurationStandard model is single stage alarm, red painted alloy, no tag or duty labels, 2 x M20 entries, 24V d.c., 6 tones, 103dBA output.

Standard models. Available ex-stock.

Standard models. Available ex-stock.

Certification Body Colour Alarm Type Voltage Ordering Code ATEX Ex II 2GD Natural Black Two Stage 12-48V d.c. PX803121 ATEX Ex II 2GD Red Two Stage 12-48V d.c. PX803123 ATEX Ex II 2GD Red Single Stage 12-48V d.c. PX803125 ATEX Ex II 2GD Natural Black Single Stage 240V a.c. PX803122 ATEX Ex II 2GD Red Single Stage 240V a.c. PX803124

Standard Product ConfigurationStandard model has 27 tones, no tag or duty labels, 2 x 20mm entries with one certified plug fitted.

Page 22: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

22 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

CertificationIntrinsically

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

No. of Tones

Options

CertificationIntrinsically Safe

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

No. of Tones

Options

ATEX GOST ‘R’ATEX Ex II 1G, EExia IIB/IIC T4Zones 0, 1, 2 and safe area use.-55°C to +70°CIP66 & 67Corrosion-free GRPUp to 3 x 20mm via knockouts1.0kg27Certification, body colour, duty & tag labels, voltages 12-24V d.c.

ATEX, CSA, FM Approved, Inmetro, IECExATEX Ex II 1G & Ex1 M1, EExia IIC T4Zone 0, Zone 1 and Zone 2 use.-20°C to +55°CIP65Corrosion-free ABSUp to 2 x 20mm via knockouts0.3kg26Body colour, tag labels, certification, voltages 12V-24V d.c.

DB5 | 103dB(A) Sounder – Explosionproof & Weatherproof

DB7 | 110dB(A) Sounder – Explosionproof & Weatherproof

Area ClassificationOperating Temperature

Ingress ProtectionMaterialEntriesWeight

No. of TonesOptions

Weatherproof.-55°C to +70°CIP66 & 67Corrosion-free GRPUp to 3 x 20mm via knockouts1kg27 + 5 programmableBody colour, tag & duty labels, voltages 12V & 24V d.c.

DB12 | 110dB(A) Sounder – Weatherproof & Heavy Duty

Sounders / Horns

Certification Voltage Ordering Code ATEX Ex II 1G 12V d.c. PX805001 ATEX Ex II 1G 24V d.c. PX805002

Standard Product ConfigurationStandard model has 26 tones, natural red body colour, no tag or duty labels, 2 x 20mm entries via knockouts.

Certification Voltage Ordering Code ATEX Ex II 1G 24V d.c. PX807006

Standard Product ConfigurationStandard model is a two stage alarm (DB7P), has 27 tones, painted red body, up to 3 x 20mm entries via knockouts.

Voltage Alarm Type Ordering Code 24V d.c. Two Stage PX808001 115/230V a.c. Single Stage PX808003

Standard Product ConfigurationStandard model has 27 tones, painted red body colour, no tag or duty labels, 3 x 20mm entries via knockouts.

Standard models. Available ex-stock.

Standard models. Available ex-stock.

Standard models. Available ex-stock.

Page 23: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

23

Area ClassificationOperating Temperature

Ingress ProtectionMaterialEntriesWeight

No. of Tones

Options

Weatherproof.-55°C to +70°CIP66 & 67Corrosion-free GRP2 x 20mm2.6kg27 + 5 programmablePainted grey, tag & duty labels, two stage alarm (DB15P) version, earth continuity, EOL resistor, volt-ages 12-48V d.c., *110-254V a.c.

*Not available in a.c. versions for DB15P.

CertificationFlameproof

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEX, Inmetro, IECExATEX Ex II 2G, EExd IIB T5Zone 1 and Zone 2 use.-20°C to +55°CIP65Cast Iron2 x 20mm11kgBody colour, tag labels, voltages 24V d.c., 240V a.c.

Weatherproof & Heavy Duty – 117dB(A) Sounder | DB15

Explosionproof & Weatherproof – 109dB(A) Bell | DB6

Voltage Body Colour Alarm Type Ordering Code 24-48V d.c. Grey Two stage PX808110 24-48V d.c. Red Two stage PX808115 240V a.c. Grey Single stage PX808120 240V a.c. Red Single stage PX808125

Standard Product ConfigurationStandard model has 27 tones, 2 x 20mm entries.

Certification Voltage Body Colour Ordering Code ATEX Ex II 2G 24V d.c. Red PX806003

Standard Product ConfigurationStandard models are in cast iron, no tag or duty labels, 2 x M20 entries.

Standard models. Available ex-stock.

Standard models. Available ex-stock.

Page 24: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

24 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

Combination UnitsCooper MEDC combination units are designed for the purpose of alerting audio and visual awareness to an emergency situation.

Our range of combination units are suitable for use in harsh environmental conditions found offshore and onshore in the oil, gas and petrochemical industries.

Page 25: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

25

Combination Beacon / Sounder | CU 1

Explosionproof — Xenon 5J; Sounder | DB3 / XB11

Explosionproof — Xenon 5J; Sounder | DB1 HP / SM87 HXB

Combination Units

CertificationFlameproof

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEX Ex II 2G, EExd(e)IIB T3Zone 1, Zone 2 & non-Ex use.-50°C to +70°C*IP66 & 67Corrosion-free GRPUp to 2 x 25mm6.5kg approxBody & lens colour, tel. initiate, earth continuity, flash rate, voltages 24–48V d.c. 110–254V a.c.

*High Temperature Unit, See data sheet for other versions.

Certification Voltage Alarm Type Lens Colour Ordering Code ATEX Ex 2GD 24V d.c. Single Stage Red 803140 ATEX Ex 2GD 24V d.c. Two Stage Red 803141 ATEX Ex 2GD 240V d.c. Single Stage Red 803142

Standard Product ConfigurationStandard models are in red finish, 10 Joules, lens guard, no tag or duty labels, 2 x M20 entries, one certified plug 60 flashes per minute.

Standard models. Available ex-stock.

Certification

Area ClassificationVoltage

Beacon

Sounder

Dimensions (mm)Options

Certification

Area ClassificationVoltage

Beacon

Sounder

Dimensions (mm)Options

ATEX: Ex II 2GD, EExdIIBT5.UL: Class I, Div. 1, Groups C & D.Model dependant - refer to datasheet24V d.c., 110V a.c., 240V a.c.Standard: XB11 (Xenon 5J).Option: Filament (10W). Flourescent (≤10W).Standard: DB3 (long flare) ≤115dBA at 1 metre.Option: DB3 (short flare) ≤108dBA at 1 metre.420 (height) x 220 (width) x 337 (depth).Refer to data sheet. Specify when ordering.

ATEX: Ex II 2G, EExdIIBT4(T3).UL: Class I, Div. 1, Groups C & D.Model dependant - refer to datasheet24V d.c., 110V a.c., 240V a.c.Standard: SM87 (Xenon 5J).Option: Filament (10W). Flourescent (≤10W).Standard: DB1 P ≤ 106dBA at 1 metreOption: DB1 HP ≤ 110dBA at 1 metre351 (height) x 228 (width) x 205 (depth).Refer to data sheet. Specify when ordering.

Ordering Information — Standard product Specify options 1 – 4

Product 1. Certification 2. Voltage 3. Lens colour 4. Finish

DB3 + XB11 ATEX UL see above Red Amber Natural Black Red+ + + +

Ordering Information — Standard product Specify options 1 – 5

Product 2. Certification 3. Voltage 4. Lens colour 5. Finish

DB1 P + SM87HXB ATEX UL see above Red Amber specify+ + + +1. Body Material

LM25 stainless steel +

Page 26: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

26 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

DB3 / SM87 HXB | Xenon 5J; Sounder — Explosionproof

DB12 / XB13 | Heavy Duty Industrial Marine Xenon 10J

Combination Units

Certification

Area ClassificationVoltageBeacon

Sounder

Beacon

Sounder

Dimensions (mm)Options

ApplicationsArea Classification

VoltageBeacon

Sounder

Dimensions (mm)

ATEX: Ex II 2G, EExdIICT5.UL: Class I, Div. 2, Groups C & D.Model dependant - refer to datasheet24V d.c., 48V d.c., 240V a.c.LM25 or stainless steel.Corrosion-free GRP.Standard: SM87 (Xenon 5J).Option: Filament (10W). Flourescent (≤10W). LED (≤192cd)Standard: DB3 (long flare) ≤ 115dB(A) at 1 metre.Option: DB3 (short flare) ≤ 108dB(A) at 1 metre (Note: Close coupled unit only available ATEX certified).420 (height) x 220 (width) x 337 (depth).Refer to data sheet. Specify when ordering.

Harsh Industrial & Marine Environments.Model dependant - refer to datasheet12V, 24V d.c., 110V, 240V a.c.Standard: XB13 (Xenon 10J).Standard: DB12 110dB(A) at 1 metre.Standard: DB15 115dB(A) at 1 metre.300 (height) x 195 (width) x 220 (depth).

Ordering Information — Standard product Specify options 1 – 5

Product 2. Certification 3. Voltage 4. Lens colour 5. Finish

DB3 / SM87 HXB ATEX UL see above Red Amber specify+ + + +1. Body Material

LM25 stainless steel +

Ordering Information — Standard product Specify options 1 – 3

Product 1. Voltage 2. Lens colour 3. Finish

DB12 / XB13 see above Red Amber Natural Red+ + +

Page 27: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

27

SpeakersCooper MEDC’s range of hazardous, heavy duty, industrial and commercial speakers are designed to meet the requirements for public address, voice alarm (evacuation) and background music. The speakers can generally operate as stand-alone units, or as part of 100 or 70 volt line systems.

Additionally a wide range of sound output levels (dB / Watts) are available. The speakers sound output in dB(A) is measured to European standards at 1 watt / 1 metre.

Page 28: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

28 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

15 Watt*

*8 Watt version has short flare.

DB4 | 8 - 25 Watt Speaker – Explosionproof & Weatherproof

CertificationFlameproof

Area Classification

Certified Ambient Temperature

Ingress ProtectionMaterial

Output

EntriesWeight

Tappings @ 25 watts

Options

ATEX, UL,GOST ‘R’ & ‘K’, SAA, InmetroATEX Ex II 2GD, EExd(e) IIC T4/T5Zone 1, Zone 2 & non-Ex use.-20°C to +70°C (standard)-55°C to +70°C (low temp unit)IP66 & 67Corrosion-free GRP107 dBA at 1W at 1 metre119 dBA at 25W at 1 metreUp to 2 x 20mm5.0kg25, 12.5, 6, 4, 2, 1Power (8W, 15W, 20W, 25W), body colour, tag & duty labels, BS5839, part 8 compliance, certification, terminal chamber, transformer voltage

DB10 | 8 & 15 Watt Speaker – Explosionproof & Weatherproof

CertificationFlameproof & Increased Safety

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterial

Output

EntriesWeight

Tappings @ 15 WattsOptions

ATEX, GOST ‘R‘ & ‘K’, CQST, InmetroATEX Ex II 2G, EExde IIB & H2 T4, T5 & T6Zone 1, Zone 2 & non-Ex use.-55°C to +70°CIP66 & 67Corrosion-free GRP105 dBA at 1W 1 metre115 dBA at 15W at 1 metreUp to 2 x 20mm3.2kg (model dependent)15, 7.5, 5, 4, 2, 0.8Body colour, tag & duty labels, transformer voltage

Sounders / Horns

Certification Power Ordering Code ATEX EX II 2GD 15 Watts PX804215 ATEX EX II 2GD 25 Watts PX804225

Standard Product ConfigurationStandard model has natural black finish, no labels, 2 x 20mm entries, fitted with one certified plug & 100V line transformer.

Standard models. Available ex-stock.

Standard models. Available ex-stock.

Certification Power Ordering Code ATEX Ex II 2G 15 Watts PX807915 ATEX Ex II 2G 8 Watts PX807908

Standard Product ConfigurationStandard model has 100V line transformer, natural black GRP body, 2 x 20mm entries, fitted with one certified plug, integral E-chamber, earth continuity.

Page 29: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

29

Area ClassificationAmbient Operating Temperature

Ingress ProtectionMaterial

Output

EntriesWeight

Tappings

Options

Weatherproof.-55°C to +70°CIP66 & 67Corrosion-free GRP107 dBA at 1W at 1 metre117 dBA at 15W at 1 metre2 x 20mm2.6kg15, 7.5, 5, 4, 2, 0.8Painted grey, tag & duty labels, transformer voltage, BS 5839, part 8 compliance, earth continuity

DB14 | 15 Watt Speaker – Weatherproof & Heavy Duty

Certification

Area Classification

Certified Ambient Temperature

Ingress ProtectionMaterial

OutputSee data sheet for additional output

EntriesWeight

Tappings @ 30 WattsOptions

ATEX, UL, GOST ‘K’, InmetroATEX Ex II 2G, EExde IIB T3ATEX Ex II 2GD, EExde IIC T110°CZone 1, Zone 2 & non-Ex use.-50°C to +65°C (25W)-50°C to +40°C (30W)IP66 & 67Corrosion-free GRPIIB version: 1W/1m is 110dBA 25W/1m is 121dBA 30W/1m is 122dBAIIC version: 3dBA less than IIB versionsUp to 2 x 20mm or 2 x 25mm5.5kg30, 25, 12, 6, 4, 2Body colour, 30W or 25W, transformer, tag & duty labels.

Explosionproof & Weatherproof – 25 and 30 Watt Speaker | DB16

Standard models. Available ex-stock.

Ordering CodePX808010

Standard Product ConfigurationStandard model has 100V line transformer, painted grey GRP body to, 2 x 20mm entries, no labels.

Page 30: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

30 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

Explosionproof & Weatherproof – 8 & 4 Watt Speaker | DB20 & DB20C

ATEX, IECEx, GOST ‘R’ and ‘K’, InmetroATEX Ex II 2G, Exde IIB T3/T4ATEX Ex II 2GD Exde IIC T4/T5Zone 1& 2 (and Zone 21 & 22 : IIC version)-55°C to +70°C (DB20) -50°C to +70°C (DB20C)IP66/67Corrosion-free GRP and ABS (DB20C)110 dB(A) (DB20) 100 dB (DB20C) at 1W at 1 metre 106 dB(A) at 4W at 1 metre109 dB(A) at 8W at 1 metre3 dB(A) higher than IIC versions2 x 20mmL137 x Ø124mm / 1.5kg4, 2, 1, 0.75, 0.38, 0.28, 4, 2, 1.5, 0.75, 0.4

CertificationFlameproof and

Increased SafetyArea Classification

Certified Operating TemperatureIngress Protection

Main body materialOutput IIC version

IIB versionEntries

Dimensions / WeightTappings @ 4 WattsTappings @ 8 Watts Available in stirrup or ceiling mount

Standard models. Available ex-stock.

Ordering Code Power PX804301 8 watts PX804302 4 watts

PX804304 8 watts PX804305 4 watts

Standard Product ConfigurationStandard ATEX IIC models have 100V line transformer, natural black GRP body, 2 x 20mm entry, one certified plug, no label.

Standard ATEX IIB models have 100V line transformer, natural black GRP body, 2 x 20mm entry, one certified plug, no label.

Sounders / Horns

Page 31: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

31

Detectors, Controls, DistributionHere at Cooper MEDC we offer standard and bespoke control and distribution units for harsh and hazardous areas.

The control units are designed with convenient operation, safety and reliability in mind. As a leading manufacturer of hazardous area and explosion proof equipment, Cooper MEDC can provide hazardous and safe area control units in a range of dimensions to suit your required specification*.

*Manufacturer dependent.

Page 32: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

32 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

CertificationFlameproof

Area ClassificationIncreased SafetyIntrinsically Safe

Certified Ambient Temperature

Ingress Protection

Material

Temperature SettingsEntriesWeight

Options

ATEX, GOST ‘R’ & ‘K’, CQST, Inmetro, Dual Listed AUATEX Ex II 2G, EExd IIB T6Zone 0, Zone 1 and Zone 2 use.ATEX Ex II 2G, EExem II T6ATEX Ex II 1G, EExia IIC T6-20°C to +125°C EExd (T3) ATEX/GOST ‘R’-20°C to +55°C EExd (T6)/EExem-55°C to +55°C EExiaIP66 & 67Marine Grade Alloy (EExd)Corrosion-free GRP (EExia/EExem)140°F to 725°F (60°C to 385°C)2 x 20mm1.1-2.0kg (model dependent)Enclosures, guard, colour, tag and duty labels, temperature setting. Series and EOL resistors, blanking plugs.

EExia/EExemEExd

HD1 EExd

HD1 EExia/EExem

HD1 | Heat Detector – Explosionproof & Intrinsically Safe

CertificationIncreased Safety

Area ClassificationCertified Operating Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEX, ULATEX Ex II 2G, EExe(m) II T3, T4, T5 & T6Zone 1 & 2 use.-55°C to +55°C (model dependent)IP66 & 67Corrosion-free GRPMultiple entries per face *1.1kg JB10 approx 1.8kg JB11 approxBody colour, tag label, terminals, external earth, gland continuity, LED, stainless steel fittings, side cable entries, high temp. version (up to +125°C)

JB10 & JB11 | GRP Junction Boxes – Explosionproof & Weatherproof

* Refer to datasheet

* Refer to datasheet

*Dependent on version

GHG 41181 | Control Units – Explosionproof & Weatherproof

CertificationIncreased Safety

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEX, ULATEX Ex II 2GD, EExed IIC T6Zones 1,2 and safe area.-55°C to +50°C, Versions with switch -55°C to +45°CIP65 & 66*Impact Resistant Thermo Plastic1x M20 Bottom entry as standardApprox. 0.5kg (model dependant)Pushbuttons, emergency stop, rotary switches & block, potentiometer, lamps, key switch, gold contact block.

Detectors, Controls & Distribution

Certification Terminals Ordering Code Model ATEX Ex II 2G 6 x SAK 2.5 PX810001 JB10

Certification Ordering Code ATEX Ex II 2GD PX809102 - Em Stop M/H* PX809101 - P/B*

Standard Product ConfiguarationStandard models have earth terminal, gland continuity,4 x M20 entries, 1 on each face, natural black finish.

Standard models. Available ex-stock.

Standard models. Available ex-stock.

Page 33: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

33

* Refer to datasheet

*Dependent on version

*Dependent on version

*Dependent on version

Explosionproof & Weatherproof – Control Units | GHG 41182

CertificationIncreased Safety

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEX, ULATEX Ex II 2GD, EExed IIC T6Zones 1,2 and safe area.-55°C to +50°C, Versions with switch -55°C to +45°CIP65 & 66*Impact Resistant Thermo Plastic1x M20 Bottom entry as standard Approx. 0.5kg (model dependant)Pushbuttons, emergency stop, contact block, padlockable, rotary switches & block, potentiometer, lamps, gold contact block, key switch.

Explosionproof & Weatherproof – Control Units | GHG 41183

CertificationIncreased Safety

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

ATEX, ULATEX Ex II 2GD, EExed IIC T6Zones 1,2 and safe area.-55°C to +50°C, Versions with switch -55°C to +45°CIP65 & 66*Impact Resistant Thermo Plastic1x M20 Bottom entry as standard Approx. 1.3kg (model dependant)Pushbuttons, emergency stop, contact block, padlockable, rotary switches & block, potentiometer, lamps, gold contact block.

Certification Ordering Code ATEX Ex II 2GD PX809201 - Start Stop* PX809202 - Start Em-Stop*

Standard models. Available ex-stock.

EExed & Weatherproof | 432 434 Range

CertificationArea Classification

Certified Ambient TemperatureIngress Protection

MaterialEntriesWeight

Options

Ex, ATEX, ULZones 1,2 and safe area-55°C to +50°C, Versions with switch -55°C to +45°CIP65/66*Impact Resistant Themo Plastic2x M20 Bottom entry as standard0.8kg to 1.6kgPushbuttons, emergency stop, contact block, rotary switches & block, potentiometer, lamps, gold contact block.

Page 34: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

34 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

A range of GRP or 316 Stainless Steel Terminal Boxes and Control Units. The Control Units can be fitted with a variety of lamps, switches, pushbuttons and other accessories.

Distribution Panels & Boards | – Explosionproof & Weatherproof

Certification ATEX, ULIncreased Safety ATEX Ex II 2GD, EExe II T4/T6*Ingress Protection IP65/66*Area Classification Model dependant - refer to datasheetMaterial Corrosion-free GRP or 316 Stainless SteelDimensions (mm): Box Type Box Type Width x Height x Depth* 444 23 744 01 271 134 136 448 23 745 02 271 271 136 449 23 746 02 544 271 136 471 23 749 04 817 271 136 444 33 744 21 175 312.5 151 448 33 745 22 312.5 312.5 151 449 33 146 23 312.5 312.5 151 447 33 749 24 941.5 312.5 151

*Dependent on version

GHG 74 & 44 Range | Terminal Boxes & Control Units – Explosionproof & Weatherproof

GP1, 2, 3 & 4 , G2, JL Range | Control Units & Motor Starters – Explosionproof & Weatherproof

A range of custom built control and motor starter units which can be used individually or combined to provide hazardous area systems for indoor or outdoor use.

Certification ATEXFlameproof ATEX Ex II 2G, EExdIngress Protection IP65 & 66Area Classification Model dependant - refer to datasheetMaterial Cast iron, Stainless Steel or Alloy *Dimensions (mm): Width x Height x DepthGP1/GP1S 580 480 240GP2/GP2S 480 275 243GP3/GP3S 580 480 365JL4/2/JL4/2S 305 265 150JL4/3/JL4/3S 305 265 237G2/G2S 156 257 175

*Model dependant

A range of custom built distribution systems utilising Cooper MEDC’s expertise in hazardous area applications to ensure a safe and reliable solution to customer specifications.

Certification ATEXFlameproof ATEX Ex II 2G, EExd IIBIngress Protection IP66Area Classification Model dependant - refer to datasheetMaterial Cast iron, Stainless Steel or Alloy. *

*Model dependant

Detectors, Controls & Distribution

Page 35: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

35

Heavy Duty Industrial & MarineCooper MEDC offer products suitable for Heavy Duty Industrial and Marine environments.

The Cooper MEDC range includes sounders, beacons, combination units in heavy duty designs with high ingress protection ratings.

Products conform to IP 66 & 67 ratings, as well as a variety of other globally recognised certifications.

Page 36: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

36 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

Area ClassificationOperating Temperature

Ingress ProtectionMaterialEntriesWeight

Options

Model dependant - refer to datasheet-55°C to +55°CIP66 & 67Corrosion-free GRP2 x 20mm0.5kgBody colour, LED, lift flap, series & EOL resistors, tag & duty labels.

Weatherproof.-55°C to +70°CIP66 & 67Corrosion-free GRP body, Polycarbonate lensUp to 3 x 20mm via knockouts1.1kgBody & lens colour, tag & duty labels, lens guard, telephone & relay initiate, single & dual flash mode, voltages 12-24V d.c., 115-230V a.c.

BG3W | Break Glass Call Point – Weatherproof & Heavy Duty

XB13 | 10 Joule Flashing Xenon – Weatherproof & Heavy Duty

Area ClassificationOperating Temperature

Ingress ProtectionMaterialEntriesWeight

Options

DB12 | 110dB(A) Sounder – Weatherproof & Heavy Duty

Weatherproof.-55°C to +70°CIP66 & 67Corrosion-free GRPUp to 3 x 20mm via knockouts1kg d.c 1.2kg a.c.27Body colour, tag & duty labels, voltages 12V & 24V d.c.

Area ClassificationOperating Temperature

Ingress ProtectionMaterialEntriesWeight

No. of TonesOptions

Heavy Duty Industrial & Marine

Ordering Code PX800006

Standard Product ConfigurationStandard models are surface mount version, have 2 x 20mm bottom entries, natural red GRP, single switch glass label ‘Fire Break Glass Press Here’, duty label ‘Burning House’

Voltage Lens Colour Ordering Code 24V d.c. Red PX813101 24V d.c. Amber PX813102 230V a.c. Red PX813103

Standard Product ConfigurationStandard models are in painted red body colour, no tag or duty labels, no lens guard, 3 x 20mm entries via knockouts, 60 flashes per minute (single flash mode), dual & single flash modes.

Voltage Alarm Type Ordering Code 24V d.c. Two Stage PX808001 115/230V a.c. Single Stage PX808003

Standard Product ConfigurationStandard model has 27 tones, painted red body colour, no tag or duty labels, 3 x 20mm entries via knockouts.

Standard models. Available ex-stock.

Standard models. Available ex-stock.

Standard models. Available ex-stock.

Page 37: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

37

*Not available in a.c. version for DB15P.

Weatherproof & Heavy Duty – 117dB(A) Sounder | DB15

Area ClassificationOperating Temperature

Ingress ProtectionMaterialEntriesWeight

No. of Tones

Options

Weatherproof.-55°C to +70°CIP66 & 67Corrosion-free GRP2 x 20mm2.6kg27 + 5 programmablePainted grey, tag & duty labels, two stage alarm (DB15P) version, earth continuity, EOL resistor, volt-ages 12-48V d.c., *110-254V a.c.

Weatherproof & Heavy Duty – 15 Watt Speaker | DB14

Area ClassificationAmbient Operating Temperature

Ingress ProtectionMaterial

Output

EntriesWeight

Tappings

Options

Weatherproof.-55°C to +70°CIP66 & 67Corrosion-free GRP107 dBA at 1W at 1 metre117 dBA at 15W at 1 metre2 x 20mm2.6kg15, 7.5, 5, 4, 2, 0.8Painted grey, tag & duty labels, transformer voltage, BS 5839, part 8 compliance, earth continuity

Voltage Body Colour Alarm Type Ordering Code 24-48V d.c. Grey Two stage PX808110 24-48V d.c. Red Two stage PX808115 240V a.c. Grey Single stage PX808120 240V a.c. Red Single stage PX808125

Standard Product ConfigurationStandard model has 27 tones, 2 x 20mm entries.

Ordering CodePX808010

Standard Product ConfigurationStandard model has 100V line transformer, painted grey GRP body to RAL 7035, 2 x 20mm entries, no labels.

Standard models. Available ex-stock.

Standard models. Available ex-stock.

Page 38: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

38 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

North American Certified ProductsThis section includes products which are internationally approved within North America.

© BP p.l.c

Page 39: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

39

North American CertificationsArea Classification

Certified Ambient Temperature

Ingress Protection

MaterialEntriesWeight

Options

Explosionproof & Weatherproof – Push Button Fire Alarm Call Point | SM87PB ULNorth American Certifications

Area Classification

Certified Ambient Temperature

Ingress Protection

MaterialEntriesWeight

Options

Hazardous Locations – Break Glass Fire Alarm Call Point | BG ULUL, Class I, Div 2, Groups A ,B, C & D, Class I, Zone 2Model dependant - refer to datasheet-13°F to +131°F-25°C to +55°CNEMA 4x & 6IP66 & 67Corrosion-free GRPUp to 4 x ½" NPT2.6lb/1.2kgBody color, tag & duty labels, LED, liftflap, series or EOL resistor, plastic element, single or double pole switch, certification

Standard models stocked in U.S. - contact the U.S. sales office

Standard models stocked in U.S. - contact the U.S. sales office

Hazardous Locations – Push Button Fire Alarm Call Point | PB UL

UL, ULC, CSA, Class I, Div 1, Groups C & D, Class I, Zone 1Model dependant - refer to datasheet-67°F to +158°F -55°C to +70°CNEMA 4x & 6IP66 & 67Marine Grade AlloyUp to 4 x ½" or ¾" NPT5.5lb/2.5kgBody color, tag & duty labels, LED, series or EOL resistor, diode, addressable module, certification

North American Certifications

Area Classification

Certified Ambient Temperature

Ingress Protection

MaterialEntriesWeight

Options

UL, CSA, Class I, Div 2, Groups A ,B, C & D, Class I, Zone 2Model dependant - refer to datasheet-13°F to +131°F-25°C to +55°CNEMA 4x & 6IP66 & 67Corrosion-free GRPUp to 4 x ½" NPT2.6lb/1.2kgBody color, tag & duty labels, LED, series or EOL resistor, single or double pole switch, certification

Exd, Weatherproof — Status Lights | SL15 ULCertification

Area ClassificationCertified Ambient Temperature

Ingress ProtectionMaterialEntries

No. of Ways

Options

UL, ATEX, and IEC Ex ApprovedModel dependant - refer to datasheet-55°C to +70°CIP66 & 67Corrosion-free GRPUp to 2 x ½" or 2 x ¾" entries. ATEX has M20 or M25.Up to 4Various flash rates available for xenon units. Various lens colours. Optional cast or wire lens guard.

UL Version

North American Certified Products

Ordering Code PX869101

Ordering Code PX869105

Product descriptionBGUL4C6C1DSN6R

Product descriptionPBUL4C6C0DSN7R

Standard models. Available ex-stock.

Standard models. Available ex-stock.

Page 40: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

40 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

SM87SL UL | Xenon, Filament & Fluorescent Status Lights – Explosionproof & Weatherproof

UL, CSA, Class I, Div 1, Groups C & D, Class I, Zone 1, AExd IIB T4 & T6Model dependant - refer to datasheet-13°F to +131°F-25°C to +55°C*NEMA 4x & 6IP66 & 67AlloyUp to 3 x ½" or ¾" NPT2,3, 4 or 5Body & lens colour, tag & duty labels, certification, voltages 24-48V d.c., 110-254V a.c.

*Model dependant, refer to data sheet.

XB11SL UL | Xenon & Filament Status Lights – Hazardous Locations

XB12SL UL | Xenon & Filament Status Lights – Hazardous Locations

North American Certifications

Area Classification

Certified Ambient Temperature

Ingress Protection

MaterialEntries

No. of Lights

Options

North American Certifications

Area Classification

Certified Ambient Temperature

Ingress Protection

MaterialEntries

No. of LightsOptions

UL, Class I, Div 2, Groups C & D, Class 1, Zones 1 & 2, AExd IIB T4Model dependant - refer to datasheet-67°F to +158°F-55°C to +70°CNEMA 4x & 6IP66 & 67Corrosion-free GRP1 x ½" NPT2,3,4, or 5Body & lens color, tag & duty labels.

North American Certifications

Area Classification

Certified Ambient Temperature

Ingress Protection

MaterialEntries

No. of Lights

Options

UL, Class I, Div 2, Groups C & D, Class I, Zones 1 & 2, AExd IIB T4 & T5Model dependant - refer to datasheet-67°F to+158°F-55°C to +70°CNEMA 4x & 6IP66 & 67Corrosion-free GRP1 x ½" NPT2, 3, 4 or 5Body & lens color, tag & duty labels, certification, voltages 24V d.c., 110-254V a.c.

North American Certified Products

Page 41: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

41

North American Certifications

Area Classification

Certified Ambient Temperature

Ingress Protection

MaterialEntriesWeight

Options

North American Certifications

Area Classification

Certified Ambient Temperature

Ingress Protection

MaterialEntriesWeight

Options

North American Certifications

Area Classification

Certified Ambient Temperature

Ingress Protection

MaterialEntriesWeight

Options

Explosionproof & Weatherproof – 5 Joule Xenon Strobe | SM87 HXB UL

UL, CSA, Class I, Div 1, Groups C & D,Class I, Zone 1, AExd IIBModel dependant - refer to datasheet-67°F to +158°F-55°C to +70°CNEMA 4x & 6IP66 & 67AlloyUp to 4 x ½" or ¾" NPT4.4lb/2.0kg approxBody & lens color, tag & duty labels,certification, lens guard, flash rate, voltages 24-48V d.c.,110-254V a.c., high temp version up to 185°F/85°C

Standard model stocked in U.S. - contact the U.S. sales office

Hazardous Locations – 5 Joule Xenon Strobe | XB11 ULUL, Class I, Div 2, Groups C & D,Class I, Zones 1 & 2, AExd IIB T5Model dependant - refer to datasheet-67°F to +158°F -55°C to +70°C NEMA 4x & 6IP66 & 67Corrosion-free GRP2 x ½" NPT5 ½ lb 2.5kgBody & lens color, tag & duty labels, lens guard, flash rate, certification, mounting method. voltages 24V d.c., 110-254V a.c,

Standard model stocked in U.S. - contact the U.S. sales office

Hazardous & Ordinary Locations – 10 Joule Flashing Xenon | XB16 ULUL 1971 compliant*, Class I, Div 2, Groups A-DClass II, Div 2, Groups F & GModel dependant - refer to datasheet-67°F to +158°F-55°C to +70°CNEMA 4x & 6IP66 & 67Corrosion-free GRPStandard 1 x ¾" NPT2.2lb/1kgBody & lens color, lens guard, tag & duty labels, initiation options, flash rate, voltages 24-48V d.c., 110-254V a.c.

* UL1971 version only available withclear lens option

Standard model stocked in U.S. - contact the U.S. sales office

Ordering Code PX869174

Ordering Code PX869407

Product descriptionXB11UL02406CNBNNNR

Product descriptionXB16UL12060RYNN

Standard models. Available ex-stock.

Standard models. Available ex-stock.

Page 42: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

42 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

North American Certifications

Area Classification

Certified Ambient Temperature

Ingress Protection

MaterialEntriesWeight

Options

XB15 UL | 15 Joule Flashing Xenon – Hazardous & Ordinary Locations

Direct Mount Pipe Mount

UL, Class I, Div 2, Groups C & D,Class I, Zones 1 & 2, AExd IIB T4 & T5Model dependant - refer to datasheet-67°F to +158°F-55°C to +70°CNEMA 4x & 6IP66 & 67Corrosion-free GRPUp to 2 x ½" NPT15.5lb/7.0kgBody & lens color, tag & duty labels, lens guard, flash rate, certification, mounting method voltages 24V d.c., 110-254V a.c.

XB12 UL | 21 Joule Xenon Strobe – Hazardous Locations

XB4 UL | 21 Joule Xenon Strobe – Explosionproof & Weatherproof

North American Certifications

Area Classification

Certified Ambient Temperature

Ingress Protection

Material

Entries

Weight

Options

UL, ULC, Class I, Div 2, Groups A, B, C, DClass II, Div 2, Groups F&G,Class I, Zone I, AExd IIC T4/T5/T6Model dependant - refer to datasheet-67°F to +158°F-55°C to +70°CNEMA 4x & 6IP66 & 67Corrosion-free GRPUp to 3 x ½” NPT or 3 x ¾” NPTPipe mount =1 x ½” or 1 x ¾” NPT5 ¾lb/2.6kg Pipe Mount6 ½lb/3.0kg Direct MountBody & lens color, relay initiate, flash rate, voltages 24-48V d.c., 110-254V a.c.

North American Certifications

Area Classification

Certified Temperature

Ingress Protection

MaterialEntriesWeight

Options

UL, Class I, Div 1, Groups C & D,Class I, Zone 1, AExd IIB T4Model dependant - refer to datasheet-67°F to +158°F-55°C to +70°CNEMA 4x & 6IP66 & 67Alloy or Stainless SteelUp to 3 x ½" or ¾" NPT14.5lb/6.6kg LM AlloyBody & lens color, tag & duty labels, lens guard, flash rate, certification, voltages 24V d.c., 110V & 240V a.c.

Standard model stocked in U.S. - contact the U.S. sales office

North American Certified Products

Ordering Code PX869402

Product descriptionXB15UL12006RWPNN

Standard models. Available ex-stock.

Page 43: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

43

North American Certifications

Area Classification

Certified Temperature

Ingress Protection

MaterialEntriesWeight

Options

North American Certifications

Area Classification

Certified Temperature

Ingress Protection

MaterialEntriesWeight

Options

Explosionproof & Weatherproof – LU3 UL 10 Watt Steady Filament Light | SM87 LU3 UL

UL, CSA, Class I, Div 1, Groups C & D,Class I, Zone 1, AExd IIBModel dependant - refer to datasheet-67°F to +131°F-55°C to +55°CNEMA 4x & 6IP66 & 67Alloy2 x ½" or ¾" NPT4.4lb/2.0kgBody & lens colour, tag & duty labels, lens guard, certification, voltages 12, 24, 48V d.c., 110V-254V a.c.

Hazardous Locations – 10 Watt Steady Filament Light | FB11 UL

*Model dependant

Hazardous Locations – 60/100 Watt Steady Filament Light | FB12 UL

UL, Class I, Div 2, Groups C & D,Class I, Zone 1, AExd IIB T4/T5Model dependant - refer to datasheet*-67°F to +131°F-55°C to +55°CNEMA 4x & 6IP66 & 67Corrosion-free GRPUp to 2 x ½" NPT16.7lb/7.6kgBody & lens color, tag & duty labels, lens guard, mounting method, certification, voltage 120V a.c.*Model dependant

North American Certifications

Area Classification

Certified Temperature

Ingress Protection

Material EntriesWeight

Options

UL, Class I, Div 2, Groups C & D, Class I, Zone 1, AExd IIB T4/T5Model dependant - refer to datasheet*-67°F to +131°F-55°C to +55°CNEMA 4x & 6IP66 & 67Corrosion-free GRPUp to 2 x ½" NPT6.2lb/2.8kgBody & lens color, tag & duty labels, lens guard, mounting method, certification, voltage 24, 48V d.c., 110 – 120V a.c.

Standard model stocked in U.S. - contact the U.S. sales office

Page 44: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

44 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

North American Certifications

Area Classification

Certified Temperature

Ingress Protection

MaterialEntriesWeight

Options

FB15 UL | 60W Steady Filament Light – Hazardous & Ordinary Locations

*Model dependant

FB4 UL | 60 Watt Steady Filament Light – Explosionproof & Weatherproof

UL, ATEX, Class I, Div 1, Groups C & D,Class I, Zone 1, AExd IIB T3 & T4Model dependant - refer to datasheet-67°F to +131°F-55°C to +55°CNEMA 4x & 6IP66 & 67AlloyUp to 3 x ½" or 2 x ¾" NPT*13lb/6.4kgBody & lens color, tag & duty labels, lens guard, relay initiate, certification, voltage 24V d.c.,110V a.c.

*Model dependant

SM87 LU1 UL | 10 Watt Steady Fluorescent Light – Explosionproof & Weatherproof

North American Certifications

Area Classification

Certified Temperature

Ingress Protection

MaterialEntries

Weight

Options

UL, Class I, Div 2, Groups A,B,C, & DClass I, Zone 1, AExd IIC T3/T4Model dependant - refer to datasheet*-67°F to +158°F-55°C to +70°CNEMA 4x & 6IP66 & 67Corrosion-free GRP / Metal Cover for Pipe Mounted UnitUp to 3 x ½" NPT or 3 x ¾" NPT5 ¾lb/2.6kg Pipe Mount6 ½lb/3.0kg Direct MountBody & lens color, lens guard, tag & duty labels, lamp wattage, unit fixing, mounting method, voltages 24-48V d.c., 110-254V a.c.

Direct Mount Pipe Mount

North American Certifications

Area Classification

Certified Temperature

Ingress Protection

MaterialEntriesWeight

Options

UL, CSA, Class I, Div 1, Groups C & D,Class I, Zone 1, AExd IIBModel dependant - refer to datasheet-67°F to +131°F-55°C to +55°CNEMA 4x & 6IP66 & 67Alloy2 x ½" or ¾" NPT4.4lb/2.0kgBody & lens colour, tag & duty labels, lens guard, certification, voltages 24-48V d.c. 220V-254V a.c.

North American Certified Products

Page 45: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

45

North American CertificationsArea Classification

Certified Temperature

Ingress Protection

MaterialEntriesWeight

No. of Tones

Options

North American CertificationsArea Classification

Certified Temperature

Ingress Protection

MaterialEntriesWeight

No. of TonesOptions

North American Certifications

Area Classification

Certified Temperature

Ingress Protection

MaterialEntriesWeight

Options

Explosionproof & Weatherproof – 13-39 Watt Steady Fluorescent Light | FL4 UL

UL, Class I, Div 1, Groups C & D,Class I, Zone 1, AExd IIC T5Model dependant - refer to datasheet-4°F to +131°F-20°C to +55°CNEMA 4x & 6IP66 & 67AlloyUp to 3 x ½" NPT or 3 x ¾" NPT*14.5lb/6.6kgBody & lens color, tag & duty labels, lens guard, relay initiate, certification, voltages 24V d.c., 110V, 240V a.c.

*Model dependant

Intrinsically Safe – FM Up to 93dB(A) @ 10ft Horn | DB5 FM UL

UL, FM, CSA, Class I, Div 1 & 2, Groups A,B,C & DModel dependant - refer to datasheet-4°F to +131°F-20°C to +55°CNEMA 4IP65Corrosion-free ABSUp to 2 x 13/16" via knockouts 0.7lb/0.3kg26Body color, label, certification, voltages 12V-24V d.c.

Standard models stocked in U.S. – contact the U.S. sales office.

Explosionproof & Weatherproof – 103dB(A) @ 10ft Horn | DB1HP UL

UL, Class I, Div 1, Groups C & D, Class I, Zone 1Model dependant - refer to datasheet-13°F to +158°F-25°C to +70°CNEMA 4x IP66AlloyUp to 3 x ½ " or ¾" NPT7.7lb/3.5kg (model dependant)27 + 5 ProgrammableBody color, tag & duty labels, certification, voltages 12,24,48V d.c., 110V a.c.

Standard models stocked in U.S. – contact the U.S. sales office.

Page 46: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

46 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

North American Certifications

Area Classification

Certified Temperature

Ingress Protection

Material

*Output

EntriesWeight

Tappings @ 30 WattsOptions

North American Certifications

Area Classification

Certified Temperature

Ingress Protection

MaterialEntriesWeight

Output

Options

DB3 UL | 115dB(A) @ 1m Horn – Hazardous Locations

Standard model stocked in U.S. – contact the U.S. sales office.

DB4 UL | 8-25 Watt Speaker – Hazardous Locations

UL, Class I, Div 2, Groups A,B,C & D,Class I, Zone 1, AExd IIC T4Model dependant - refer to datasheet-67°F to +158°F-55°C to +70°CNEMA 4x & 6IP66 & 67Corrosion-free GRPUp to 2 x ½” NPT11lb/5.0kg97 dBA at 1W at 10 feet109 dBA at 25W at 10 feetBody color, tag & duty labels, transformer, certification, power 25W, 15W, 8W

DB16 UL | 30 Watt Speaker – Hazardous Locations

UL, Class I, Div 2, Groups C & D/A-DClass I, Zone 1, AExde IIB T3/IIC T110°CModel dependant - refer to datasheet-61°F to +90°F-50°C to + 40°CNEMA 4x & 6IP66 & 67Corrosion-free GRPGroups C & D: 100dBA at 1Watt at 10 feet 112dBA at 30 Watts at 10 feetGroups A-D: 3dBA less than C & D versionsUp to 2 x ½" NPT or 2 x ¾" NPT12.1lb/5.5kg30, 25, 12, 6, 4, 2Body color, transformer, tag & duty labels.

*See data sheet for additional output.

North American Certifications

Area Classification

Certified Temperature

Ingress Protection

MaterialEntriesWeight

No. of Tones

Options

UL, ULC, Class I, Div 2, Groups A,B,C & DClass II, Div 2, Groups F & GClass I, Zones 1 & 2, AExd IIC T4Model dependant - refer to datasheet-67°F to +158°F-55°C to +70°C NEMA 4x & 6IP65 & 67Corrosion-free GRPUp to 2 x ½" NPT 11lb/5.0kg27 + 5 ProgrammableBody color, tag & duty labels, end of line resistor, certification, voltages 12-48V d.c., 110V-254V a.c.

North American Certified Products

Ordering Code PX869131

Product descriptionDB3UL048N2CNRZ

Standard models. Available ex-stock.

Page 47: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

47

Hazardous Locations – Control Units | GHG 41181 UL

Hazardous Locations – Control Units | GHG 41182 UL

North American Certifications

Area Classification

Certified Temperature

Ingress Protection

MaterialEntriesWeight

Options

UL, Class I, Div 2, Groups A,B,C & DClass I, Zone 1, AExde IIB+H2 T6Class II, Div 1, Groups E,F&G(cUL)Model dependant - refer to datasheet-4°F to + 104°F-20°C to +40°CNEMA 4x & 6, IP65 & 66Impact Resistant Thermo Plastic1 x ½" NPT as standard0.5kg - 1.3kgPushbuttons, emergency stop, padlockable, contact block, rotary switches & block, potentiometer, lamps

North American Certifications

Area Classification

Certified Temperature

Ingress Protection

MaterialEntriesWeight

Options

UL, ATEX, Class I, Div 2, Groups A,B,C & DClass I, Zone 1, AExde IIB+H2 T6Class II, Div 1, Groups E,F&G(cUL)Model dependant - refer to datasheet-4°F to + 104°F-20°C to +40°CNEMA 4x & 6, IP65 & 66Impact Resistant Thermo Plastic1 x ½" NPT as standard0.5kg - 1.3kgPushbuttons, emergency stop, padlockable, contact block, rotary switches & block, potentiometer, lamps

Hazardous Locations – Control Units | GHG 41183 UL

*Model dependent

North American Certifications

Area Classification

Certified Temperature

Ingress ProtectionMaterialEntriesWeight

Options

UL, Class I, Div 2, Groups A,B,C & DClass I, Zone 1, AExde IIB+H2 T6Class II, Div 1, Groups E,F&G(cUL)Model dependant - refer to datasheet-4°F to + 104°F-20°C to +40°CNEMA 4x & 6, IP65 & 66*Impact Resistant Thermo Plastic1 x ½" NPT as standard0.5kg - 1.3kgPushbuttons, emergency stop, padlockable, contact block, rotary switches & block, potentiometer, lamps

Page 48: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

48 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

North American Certifications

Area Classification

Certified Temperature

Ingress ProtectionMaterialEntriesWeight

Options

All specifications, dimensions, weights and tolerances are nominal (typical) and MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use.

GHG 74 & 44 UL | Terminal Boxes & Control Units – Hazardous Locations

A range of GRP Terminal Boxes and Control Units. The Control Units can be fitted with a variety of lamps, switches, pushbuttons and other accessories.

JB10 & JB11 UL | GRP Junction Boxes – Explosionproof & Weatherproof

UL, Class I, Div 2, Groups A,B,C & DClass I, Zone 1, AExe IIC T4 & T5Model dependant - refer to datasheet-67°F to +131°F-55°C to +55°CNEMA 4x & 6, IP66 & 67Corrosion-free GRPUp to 8 entries (model dependent)2.4-4lbs/1.1kg-1.8kgBody color, tag label, gland continuity, extra internal earth, terminal type

*Model dependant

*Model dependant

Dimensions (mm):Box Type Box Type Width x Height x Depth*444 23 744 01 271 134 136448 23 745 02 271 271 136449 23 746 02 544 271 136471 23 749 04 817 271 136444 33 744 21 175 312.5 151448 33 745 22 312.5 312.5 151449 33 146 23 312.5 312.5 151447 33 749 24 941.5 312.5 151

UL Class I, Div 2, Groups A,B,C & DClass I, Zone 1, Groups A,B,C & DClass II, Div 1, Groups E, F & GAExde IIC T4, T6*Model dependant - refer to datasheetIP65/66*Corrosion-free GRP or316 Stainless Steel

North American Certifications

Increased Safety

Area ClassificationIngress Protection

Material

North American Certified ProductsNorth American Certified Products

432 434 Range | EExed & Weatherproof

North American Certification

Area Classification

Certified Ambient Temperature

Ingress ProtectionMaterialEntriesWeight

Options

Ex, ATEX, ULClass I, Zone 1, AExde IIB+H2 T6Class II, Div 1, Groups E,F&G(cUL)-4°F to + 104°F -20°C to +40°CNEMA 4x & 6, IP65 & 66*Impact Resistant Themo Plastic2 x ½" NPT as standard1.75lbs–3.5lbs / 0.8kg–1.6kgPushbuttons, emergency stop, padlockable, contact block, rotary switches & block, potentiometer, lamps.

Page 49: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

49

Notes

Page 50: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

50 www.medc.com UK Tel: +44 (0) 1773 864100 US Tel: + 1 (713) 937 9772

North American Certified ProductsNotes

Page 51: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

Suppliers to:Cooper MEDC Offices

Cooper MEDC Distribution

Cooper MEDC World-wide

Globally certified with proven pedigree of service since 1975.Highest quality in-house design, certification and build.Highly specified by oil and gas companies world-wide.World leaders in signal and alarm notification products.Highest quality vertically integrated manufacturing.

Page 52: MEDC Product Overview - Cooper MEDC€¦ · MEDC Product Overview World class manufacturers of alarm, signalling and notification products for ... by offering a comprehensive range

Cooper MEDC LtdColliery RoadPinxtonNottinghamNG16 6JFUnited Kingdom

P: + 44 (0) 1773 864100F: + 44 (0) 1773 582800www.medc.com

Cooper MEDC (USA)3413 North Sam HoustonParkway West HoustonTX 77086USA

P: + 1 (713) 937 9772F: + 1 (713) 937 9773

Cooper Industries600 Travis, Suite 5600Houston, Texas 77002-1001P: 713-209-8400www.cooperindustries.com

Cooper Safety LtdJephson CourtTancred CloseRoyal Leamington SpaWarwickshireCV31 3RZUnited Kingdom

P: + 44 (0) 1926 439 202www.cooper-safety.com