Rev 1.0
Mellanox Technologies 16
4.1 OpenSM Activation
OpenSM is a service required by managed networks in InfiniBand environments, and must be acti-vated in one of the machines running on the subnet, otherwise the interface link will not come up. If the cards are connected to a managed network, there is no need to run OpenSM. Only one OpenSM should run per subnet.
In Ethernet interfaces, running OpenSM is not required.
OpenSM is embedded in the MLNX_VPI for Windows package and installed as a disabled Win-dows service.
To enable it, after installing the WinOF package, enter at the command line:
For further information, please refer to the “OpenSM - Subnet Manager” chapter in the User Man-ual.
> sc start opensm
Rev 1.0
Mellanox Technologies 18
Appendix B: Supported Device IDs
Windows 8 is able to burn firmware for the following devices: 0x1003 0x6732 0x673c 0x6750 0x676e