metroselect configuration guide 02407h

Upload: raptornegro

Post on 03-Jun-2018

222 views

Category:

Documents


1 download

TRANSCRIPT

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    1/210

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    2/210

    Copyright

    2007 by Metrologic Instruments, Inc. All rights reserved. No part of thiswork may be reproduced, transmitted, or stored in any form or by any means

    without prior written consent, except by reviewer, who may quote briefpassages in a review, or provided for in the Copyright Act of 1976.

    Trademarks

    Metrologic is a registered trademark of Metrologic Instruments, Inc.Products identified in this document are hereby acknowledged astrademarks, registered or otherwise, of Metrologic Instruments, Inc. or theirrespective companies.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    3/210

    Table of Contents iii

    TABLE OF CONTENTS

    IntroductionSymbol Key ................................................................................................. xi

    Bar Code Configuration MethodsSingle-Code Method................................................................................... xiiMulti-Code Method ..................................................................................... xii

    Need to Start Over?Recall Defaults ...........................................................................................xiii

    Section A: Code Types and Decode RulesUPC/EAN......................................................................................................1 Code 128......................................................................................................3Code 39........................................................................................................4Interleaved 2 of 5..........................................................................................6Standard 2 of 5.............................................................................................9Other 2 of 5 Codes .....................................................................................10Codabar......................................................................................................12 Code 93......................................................................................................13Code 11......................................................................................................13Telepen.......................................................................................................14 Plessey Codes............................................................................................15Other Decode Features..............................................................................17Configurable Code Lengths........................................................................18RSS 14 Features........................................................................................21RSS Limited Features ................................................................................23RSS Expanded Features............................................................................25

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    4/210

    Table of Contents iv

    TABLEOFCONTENTSSection B: Supplements

    Two Digit Supplements/Redundancy ...........................................................1Five Digit Supplements/Redundancy ...........................................................1Supplements Required/Not Required...........................................................2Remote Supplemental Requirement ............................................................2Bookland (978) Supplement Required .........................................................3977 (2 Digit) Supplement Required ..............................................................3378/379 French Supplement Requirement...................................................3434/439 German Supplement Required.......................................................4414/419 German Supplement Required.......................................................4# System 2 Requires Supplements ..............................................................4# System 5 Requires Supplements ..............................................................58711685 Requires 5-Digit Supplements.......................................................5Coupon Code 128 ........................................................................................5Code 128 Group Separators ........................................................................6Code 128 ]C1 Extended Code Format........................................................6100 msec to Find Supplemental...................................................................6200 msec to Find Supplemental...................................................................6400 msec to Find Supplemental...................................................................7Code IDs with Supplements ........................................................................7Allow 2/5 on 977 Bar Code...........................................................................7Allow 2 on 977 Bar Code..............................................................................7Beep Once/Twice on Supplements .............................................................. 8ISBN Check Digit Transmission ...................................................................8Bookland to ISBN Conversion......................................................................9

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    5/210

    Table of Contents v

    TABLEOFCONTENTSISBN Re-Formatting .....................................................................................9

    ISSN Check Digit Transmission .................................................................10ISSN Re-Formatting ...................................................................................10977 to ISSN Conversion.............................................................................10Number System 4 Coupon Code 128.........................................................11UPC Discard...............................................................................................11Supplements and UPC in Same Line.........................................................11

    Section C: CommunicationsEnable RS-232 .............................................................................................1Load Keyboard Wedge Defaults...................................................................1Enable Light Pen/Wand Communication......................................................1Enable Keyboard Wedge Emulation.............................................................1Enable Stand-Alone Keyboard Scanner.......................................................1Load OCIA Defaults......................................................................................2Enable OCIA Output.....................................................................................2Load IBM 46xx Defaults ...............................................................................2Enable IBM 46xx Communication ................................................................2Low Speed USB ........................................................................................... 3Enable No Communication Mode.................................................................3Reserved ......................................................................................................3

    Section D: Scanner OperationConfiguration Mode Options.........................................................................1Scan Buffers.................................................................................................2Redundant Scans.........................................................................................4Miscellaneous Decode Features ..................................................................6Depth of Field Adjustments ..........................................................................7

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    6/210

    Table of Contents vi

    TABLEOFCONTENTSSame Symbol Time Outs..............................................................................8Barcode Absence .........................................................................................9LED Options ...............................................................................................10Beeper Options...........................................................................................12Inter-Character Data Transmission Delays ................................................17Inter-Record Data Transmission Delays.....................................................18Communication Time Out Options ............................................................. 19Host Scanner Commands ..........................................................................21Power Save Modes ....................................................................................26Japanese Double Field Support .................................................................30Test Modes.................................................................................................35

    Section E: Prefixes/SuffixesConfigurable Prefixes, All Data.....................................................................1Configurable ID Characters, Code Specific..................................................3

    Identifiers Character ...........................................................................3Standard Prefix Characters ..........................................................................8Standard Suffix Characters ........................................................................14Longitudinal Redundancy Check (LRC) .....................................................16Configurable Suffixes, All Data...................................................................17Special Formats..........................................................................................20Character Replacements............................................................................21

    Section F: Code FormattingUPC/EAN......................................................................................................1 Codabar........................................................................................................5 Code 39........................................................................................................7Code 11........................................................................................................9

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    7/210

    Table of Contents vii

    TABLEOFCONTENTSTelepen.........................................................................................................9

    Plessey.......................................................................................................10 2 of 5...........................................................................................................12

    Section G: RS-232Enable RS-232 Mode ...................................................................................1Parity Features .............................................................................................2Baud Rates...................................................................................................3Data/Stop Bits...............................................................................................5Hardware Handshaking................................................................................6Software Handshaking .................................................................................9Miscellaneous.............................................................................................12

    Section H: KeyboardEnable Keyboard Emulation.........................................................................1Country/Scan Code Table Selects ...............................................................2Keyboard/System Type ................................................................................4Special Keyboard Features ..........................................................................5Inter-Scan Code Delays ...............................................................................9Control Sets................................................................................................103151 Terminal Keyboard ............................................................................12

    Section I: OCIALoad OCIA Defaults......................................................................................1Enable OCIA.................................................................................................1DTS/Siemens ...............................................................................................1DTS/Nixdorf..................................................................................................1 NCR-S ..........................................................................................................1NCR-F ..........................................................................................................1

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    8/210

    Table of Contents viii

    TABLEOFCONTENTSSection J: Light Pen/Laser Emulation

    Enable Light Pen Mode ................................................................................1Space/Bar Height .........................................................................................1Transmit Code 39.........................................................................................1Transmit as Scanned....................................................................................1Poll Light Pen Source...................................................................................2Light Pen Extra Toggle.................................................................................210x Narrow Element Border .........................................................................250x Narrow Element Border .........................................................................2Set Narrow Element Width ...........................................................................3Laser Emulation............................................................................................3

    Section K: IBM 46xx ConfigurationEnable IBM 46xx Communication ................................................................1Load IBM 46xx Defaults ...............................................................................1IBM Ports......................................................................................................1IBM Reserve Codes .....................................................................................2

    Section M: Code BytesCode Byte Usage .........................................................................................1Code Bytes 0-5.............................................................................................2Code Bytes 6-9.............................................................................................3Reserved Codes...........................................................................................4Code Byte/Code Type Table ........................................................................5

    ASCII Reference Table.................................................................................6Extended Key Code Reference Table........................................................11

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    9/210

    Table of Contents ix

    TABLEOFCONTENTS

    Section N: Miscellaneous FeaturesCustom Defaults...........................................................................................1Serial Configuration Mode............................................................................5Software/Serial Number ...............................................................................5

    Section O: Auxiliary Port ControlsDisable AUX Port..........................................................................................1AUX Port and Secondary Device Data Formats

    When Using a Metrologic Device as a Secondary..............................1When Using a Non-Metrologic RS-232 Device as a Secondary.........3

    Additional AUX Port Data Formats...............................................................4AUX Port Baud Rates...................................................................................5AUX Port Parity ............................................................................................7AUX Port Stop/Data Bits...............................................................................8Enable/Disable RTS/CTS Handshaking.......................................................9Message AUX RTS/CTS ..............................................................................9Character AUX RTS/CTS.............................................................................9Enable/Disable Port Mode 7.........................................................................9Enable/Disable D/E Commands.................................................................10Enable/Disable F/L Commands..................................................................10Enable/Disable M/O Commands ................................................................10Enable/Disable XON/XOFF Handshaking..................................................11Enable/Disable ACK/NAK...........................................................................11AUX CTS/RTS Polarity...............................................................................12AUX Same Symbol Timeout.......................................................................12Main Output Port Auxiliary Data Formats...................................................13

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    10/210

    Table of Contents x

    TABLEOFCONTENTSInter-Character Delays ...............................................................................15Inter-Character De lays ..............................................................................16

    Section P: USB .................................................................................................. 1Section R: IS3480 / MS3580 / MS3780

    Button Modes ............................................................................................... 1Button Click Delay ........................................................................................1Primary and Secondary Scan Patterns ........................................................2Sweet Spot Mode (IS3480) ..........................................................................4CodeGate (IS3480 / MS3580)......................................................................4Depth of Field ...............................................................................................4IR Activation .................................................................................................5TTL RS232 ...................................................................................................5CodeGate (MS3780) ....................................................................................6Modes (MS3780)..........................................................................................7

    Section S: Protocol FormattingROM Emulation ............................................................................................1

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    11/210

    Introduction xi

    INTRODUCTION

    Your new scanner has been configured at the factory with a set of default communicationprotocols. Since many host systems have unique formats and protocol requirements,Metrologic provides a wide range of configurable features that may be selected with theuse of this bar code configuration guide.

    Once the configuration is completed, the scanner stores the settings in nonvolatilememory or NOVRAM. NOVRAM saves the settings when the power is turned off.

    Symbol Key

    * (asterisk) Default Feature

    ~ (tilde)Feature requires the Multi-CodeConfiguration Method,

    see Bar Code Configuration Methods on page xii.

    Important!

    Note

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    12/210

    Bar Code Configuration Methods xii

    BAR CODE CONFIGURATION METHODS

    Metrologic scanners can be bar code configured in two ways: the Single-Code Method

    and the Multi-Code Method.

    Single-CodeMethod

    Most features can be enabled or disabled using the Single-Code Method.

    1. Power up the scanner.

    2. Scan the bar code(s) for the desired feature(s).3. Observe a multi-toned, save setting beep that indicates the configuration has

    been saved to NOVRAM.

    Multi-CodeMethod

    All features can be enabled or disabled using the Multi-Code Method.A feature marked with a ~ requires the Multi-Code Method.

    1. Power up the scanner.

    2. Scan the Enter/Exit Configuration Modebar code. [3 beeps]

    3. Scan the bar code(s) for the desired feature(s). [1 beep]

    4. Scan the Enter/Exit Configuration Modebar code [3 beeps] andsave new configuration.

    Enter/Exit Configuration Mode

    9 9 9 9 9 9

    To abort a configuration change, power off the scanner before scanning theEnter/Exit Configuration Modebar code.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    13/210

    Need to Start Over? xiii

    NEED TO START OVER?

    Scan the Recall Default bar code. This will erase all previous settings and return to thescanners default communications protocol.

    Keyboard Wedge interface scanners will load keyboard wedge defaults. All other scanners will load RS232 defaults.

    Metrologic manufactures custom OEM scanners, which load the OEMsdefaults. For further information on the affects they have on Metrologic defaultcommunications protocols refer to Section N, Custom Defaults.

    Recall Defaults

    9 9 9 9 9 8

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    14/210

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    15/210

    Code Types & Decode Rules A 1

    SECTIONA UPC/EAN

    * Enable UPC/EAN Disable UPC/EAN

    1 0 0 1 1 6 1 0 0 1 0 6

    * Enable UPC-A Disable UPC-A

    1 0 0 2 1 6 1 0 0 2 0 6

    * Enable UPC-E Disable UPC-E

    1 0 0 2 1 0 1 0 0 2 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    16/210

    Code Types & Decode Rules A 2

    SECTIONA UPC/EAN

    * Enable EAN-13 Disable EAN-13

    1 0 0 2 1 1 1 0 0 2 0 1

    * Enable EAN-8 Disable EAN-8

    1 0 0 2 1 4 1 0 0 2 0 4

    * EnableAuto Redundancy UPC-E

    DisableAuto Redundancy UPC-E

    1 0 1 1 0 4 1 0 1 1 1 4

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    17/210

    Code Types & Decode Rules A 3

    SECTIONA CODE 128

    * Enable Code 128 Disable Code 128

    1 0 0 1 1 3 1 0 0 1 0 3

    EnableUCC/EAN-28]C1 Code Formatting

    DisableUCC/EAN-128]C1 Code Formatting

    1 0 0 3 1 4 1 0 0 3 0 4

    For Coupon Code 128, see Section B, page 5.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    18/210

    Code Types & Decode Rules A 4

    SECTIONA CODE 39

    * Enable Code 39 Disable Code 39

    1 0 0 1 1 1 1 0 0 1 0 1

    Enable MOD 43Check on Code 39

    * Disable MOD 43Check on Code 39

    1 0 0 2 1 3

    The scanner will only scanCode 39 bar codes thathave a valid Modulo 43check digit.

    1 0 0 2 0 3

    The scanner will not testCode 39 bar codes for amodulo 43 check digit.

    Transmit Mode 43 CheckDigit on Code 39

    * Do Not Transmit Mode 43Check Digit on Code 39

    1 0 7 7 1 5

    This feature works inconjunction with Mode 43Check on Code 39. Bothoptions must be enabled for

    this feature to work.

    1 0 7 7 0 5

    This option will not transmitCode 39s Mod 43 checkcharacter.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    19/210

    Code Types & Decode Rules A 5

    SECTIONA CODE 39

    Enable Full ASCII Code 39 * Disable Full ASCIICode 39

    1 0 0 2 1 7 1 0 0 2 0 7

    Enable PARAF Support(Italian Pharmaceutical Codes) * Disable PARAF Support

    1 0 0 2 1 5

    The scanner will convertCode 39 bar codes toPARAF format.

    1 0 0 2 0 5

    The scanner will not convertcode 39 bar codes toPARAF format.

    Enable TRI-OPTIC Code * Disable TRI-OPTIC Code

    1 0 0 3 1 2 1 0 0 3 0 2

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    20/210

    Code Types & Decode Rules A 6

    SECTIONA INTERLEAVED 2OF 5

    * Enable Interleaved

    2 of 5 (ITF)

    Disable Interleaved

    2 of 5 (ITF)

    1 0 0 1 1 5 1 0 0 1 0 5

    Enable MOD 10Check on ITF

    * Disable MOD 10Check on ITF

    1 0 0 3 1 0

    The scanner will only scanInterleaved 2 of 5 (ITF)Bar codes that have aModulo 10 check digit.

    1 0 0 3 0 0

    The scanner will not testInterleaved 2 of 5 (ITF)bar codes for a Modulo 10check digit.

    Transmit MOD 10Check Digit on ITF

    * Do Not Transmit MOD 10Check Digit on ITF

    1 0 7 7 1 4

    The scanner transmitsInterleaved 2 of 5 (ITF)MOD 10 check character.

    1 0 7 7 0 4

    The scanner will nottransmit Interleaved 2 of 5(ITF) MOD 10 check digitcharacters. This featureworks in conjunction withMod 10 Check on ITF. Bothmust be enabled for this

    feature to work.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    21/210

    Code Types & Decode Rules A 7

    SECTIONA INTERLEAVED 2OF 5

    Enable ALTCheck Digit ITF

    * Disable ALTCheck Digit ITF

    1 0 0 7 1 7 1 0 0 7 0 7

    Enable 12 Digit ITFCheck Digit at 1 * Normal Check Digit

    1 0 0 9 1 0

    This feature requiresMOD 10 ITF Check Digittobe enabled. The 12-

    character ITF check digitcalculation will start with 1instead of 0.

    1 0 0 9 0 0

    Enable ITF/Code 39 Filter* Disable ITF/Code 39

    Filter

    1 0 0 4 1 6

    Supports Code 39/ITF filters.

    This feature may adverselyaffect reading Codabar,Code 93 and some othernon-standard symbologies.

    1 0 0 4 0 6

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    22/210

    Code Types & Decode Rules A 8

    SECTIONA INTERLEAVED 2OF 5

    ~ ITF Symbol Length

    Lock 1

    ~ ITF Symbol Length

    Lock 2

    9 0 1 6 0 0

    To specify a 1stITF symbol

    length lock, scan the abovebar code and theappropriate code byteslocated in Section M.

    9 0 1 7 0 0

    To specify a 2ndITF symbol

    length lock, scan the abovebar code and theappropriate code byteslocated in Section M.

    ~ ITF MinimumSymbol Length

    9 0 3 4 0 0 To specify a minimumnumber of ITF characters tobe decoded, scan the abovebar code and theappropriate code byteslocated in Section M.

    Refer to the Multi-CodeConfiguration Method onpage xii.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    23/210

    Code Types & Decode Rules A 9

    SECTIONA STANDARD 2OF 5

    EnableStandard 2 of 5

    * DisableStandard 2 of 5

    1 0 0 1 1 0 1 0 0 1 0 0

    ~ Standard 2 of 5Symbol Length Lock

    9 0 1 5 0 0

    To specify a minimumnumber of ITF characters tobe decoded, scan the abovebar code and theappropriate code byteslocated in Section M.

    Refer to the Multi-Code configurationmethod on page xii.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    24/210

    Code Types & Decode Rules A 10

    SECTIONA OTHER 2OF 5CODES

    Enable Matrix 2 of 5 * Disable Matrix 2 of 5

    1 0 0 0 1 5 1 0 0 0 0 5

    Enable 15 Digit

    Airline 2 of 5

    * Disable 15 Digit

    Airline 2 of 5

    1 0 0 0 1 4 1 0 0 0 0 4

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    25/210

    Code Types & Decode Rules A 11

    SECTIONA OTHER 2OF 5CODES

    Enable 13 DigitAirline 2 of 5

    * Disable 13 DigitAirline 2 of 5

    1 0 0 3 1 3 1 0 0 3 0 3

    Enable Hong Kong2 of 5

    * Disable Hong Kong2 of 5

    1 0 0 3 1 6 1 0 0 3 0 6

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    26/210

    Code Types & Decode Rules A 12

    SECTIONA CODABAR

    * Enable Codabar * Disable Codabar

    1 0 0 1 1 4 1 0 0 1 0 4

    EnableDual Field Codabar

    * DisableDual Field Codabar

    1 0 0 0 1 2 1 0 0 0 0 2

    EnableTab in Dual Codabar

    * DisableTab in Dual Codabar

    1 0 8 0 1 2

    This feature requires DualField Codabar to beenabled. The scanner willinsert a tab between thefields of the dual fieldCodabar.

    1 0 8 0 0 2

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    27/210

    Code Types & Decode Rules A 13

    SECTIONA CODE 93AND CODE 11

    * Enable Code 93 Disable Code 93

    1 0 0 1 1 2 1 0 0 1 0 2

    Enable Code 11 * Disable Code 11

    1 0 0 0 1 3 1 0 0 0 0 3

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    28/210

    Code Types & Decode Rules A 14

    SECTIONA TELEPEN

    Enable Telepen * Disable Telepen

    1 0 0 0 1 7 1 0 0 0 0 7

    EnableALPHA Telepen

    * DisableALPHA Telepen

    1 0 0 0 1 6 1 0 0 0 0 6

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    29/210

    Code Types & Decode Rules A 15

    SECTIONA PLESSEY CODES

    Enable MSI Plessey * Disable MSI Plessey

    1 0 0 2 1 2 1 0 0 2 0 2

    * No MSI PlesseyCheck Digit

    2 0 0 7 0 4

    The scanner will not testMSI Plessey bar codes for acheck digit.

    Enable MSI PlesseyMOD 10/10 Check Digit

    * Enable MSI Plessey MOD10 Check Digit

    2 0 0 7 3 4

    The scanner will test MSIPlessey bar codes for adouble Modulo 10 check

    digit.

    2 0 0 7 2 4

    The scanner will test MSIPlessey bar codes for asingle Modulo 10 check

    digit.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    30/210

    Code Types & Decode Rules A 16

    SECTIONA PLESSEY CODES

    Transmit

    MSI Plessey Check Digit

    * Do Not Transmit

    MSI Plessey Check Digit

    1 0 7 7 1 1

    This option works in

    conjunction with one or bothof the Enabled MSI PlesseyMode options.

    1 0 7 7 0 1

    The scanner will not

    transmit MSI Plessey checkdigit characters.

    Enable UK Plessey * Disable UK Plessey

    1 0 0 1 1 7 1 0 0 1 0 7

    Enable UK PlesseyA to X Conversion

    * Disable UK PlesseyA to X Conversion

    1 0 0 7 1 6 1 0 0 7 0 6

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    31/210

    Code Types & Decode Rules A 17

    SECTIONA OTHER DECODE FEATURES

    Enable Double BorderRequired/LargeInter-Character Space

    * Disable Double BorderRequired/LargeInter-Character Space

    1 0 0 0 1 1 1 0 0 0 0 1

    ~ MinimumSymbol Length

    ~ Symbol Length Lock

    9 0 1 8 0 0

    Omnidirectional default is 4.Combine this code with theproper Code Bytes, tospecify the minimumnumber of characters in allnon-UPC/EAN bar codes.

    9 0 1 9 0 0

    This code combined with theproper Code Bytes, locks thebar codes length into place.

    Refer to the Multi-Code Configuration Method on page xii.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    32/210

    Code Types & Decode Rules A 18

    SECTIONA CONFIGURABLE CODE LENGTHS

    There are seven bar code lock lengths available. Specific code types can be assigned to

    a lock length using the Multi-Codeconfiguration method.

    Example:

    1. Scan the enter/exit configuration bar code.

    2. Scan the code length lock #1bar code.

    3. Scan the three Code Bytes that represent the code length.

    4. Scan the matching code type lock #1 bar code.

    5. Scan the three code bytes that represent the code type.

    Refer to the Code Type Tablein Section M.

    6. Repeat steps 2 through 5 for lock lengths 2 through 7 if desired.

    7. Scan the enter/exit configuration bar code when finished to save settings.

    ~ Code LengthLock #1

    ~ Code TypeLock #1

    9 0 2 0 0 0 9 0 2 1 0 0

    ~ Code Length

    Lock #2

    ~ Code Type

    Lock #2

    9 0 2 2 0 0 9 0 2 3 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    33/210

    Code Types & Decode Rules A 19

    SECTIONA CONFIGURABLE CODE LENGTHS

    ~ Code LengthLock #3

    ~ Code TypeLock #3

    9 0 2 4 0 0 9 0 2 5 0 0

    ~ Code LengthLock #4

    ~ Code TypeLock #4

    9 0 2 6 0 0 9 0 2 7 0 0

    ~ Code LengthLock #5

    ~ Code TypeLock #5

    9 0 2 8 0 0 9 0 2 9 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    34/210

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    35/210

    Code Types & Decode Rules A 21

    SECTIONA RSS14FEATURES

    Enable RSS 14 * Disable RSS 14

    1 0 0 4 1 3 1 0 0 4 0 3

    * Transmit

    RSS 14 Check Digit

    Do Not Transmit

    RSS 14 Check Digit

    1 1 4 9 0 0 1 1 4 9 1 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    36/210

    Code Types & Decode Rules A 22

    SECTIONA RSS14FEATURES

    * Transmit

    RSS 14 Application ID

    Do Not Transmit

    RSS 14 Application ID

    1 1 4 9 0 1

    Application identifier 01 is

    transmitted by default.

    1 1 4 9 1 1

    * TransmitRSS 14 Symbology ID

    Do Not TransmitRSS 14 Symbology ID

    1 1 4 9 0 2

    Symbology identifier ]e0 istransmitted by default.

    1 1 4 9 1 2

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    37/210

    Code Types & Decode Rules A 23

    SECTIONA RSSLIMITED FEATURES

    Enable RSS Limited * Disable RSS Limited

    1 0 0 4 1 4 1 0 0 4 0 4

    * TransmitRSS Limited Check Digit

    Do Not TransmitRSS Limited Check Digit

    1 1 4 9 0 3 1 1 4 9 1 3

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    38/210

    Code Types & Decode Rules A 24

    SECTIONA RSSLIMITED FEATURES

    * Transmit RSS Limited

    Application ID

    Do Not Transmit

    RSS Limited Application ID

    1 1 4 9 0 4

    Application identifier 01 is

    transmitted by default.

    1 1 4 9 1 4

    * Transmit RSS LimitedSymbology ID

    Do Not TransmitRSS Limited Symbology ID

    1 1 4 9 0 5

    Symbology identifier ]e0 istransmitted by default.

    1 1 4 9 1 5

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    39/210

    Code Types & Decode Rules A 25

    SECTIONA RSSEXPANDED FEATURES

    Enable RSS Expanded * Disable RSS Expanded

    1 0 0 4 1 5 1 0 0 4 0 5

    * Transmit RSSExpanded Symbology ID

    Do Not Transmit RSSExpanded Symbology ID

    1 1 4 9 0 6

    Symbology identifier ]e0 istransmitted by default.

    1 1 4 9 1 6

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    40/210

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    41/210

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    42/210

    Supplements B 2

    SECTION B SUPPLEMENTS/REDUNDANCY

    Enable Five Digit

    Redundancy

    * Disable Five Digit

    Redundancy

    1 0 1 2 1 1

    Twice before accepting

    data, the scanner will scanthe bar code plus the fivedigit add on.

    1 0 1 2 0 1

    The scanner will not

    implement the five digitredundancy feature.

    Supplementsare Required

    * Supplements arenot Required

    1 0 1 2 1 3

    All UPC/EAN labels that arescanned must have asupplement.

    1 0 1 2 0 3

    UPC/EAN labels do notrequire a supplement to bescanned.

    Enable RemoteSupplemental Requirement

    * DisableRemote SupplementalRequirement

    1 0 1 4 1 6 1 0 1 4 0 6

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    43/210

    Supplements B 3

    SECTION B SUPPLEMENTS

    Enable Bookland (978)Supplement Requirement

    * Disable Bookland (978)Supplement Requirement

    1 0 1 4 1 7 1 0 1 4 0 7

    Enable 977 (2 digit)

    Supplemental Requirement

    * Disable 977 (2 digit)SupplementalRequirement

    1 0 1 3 1 4

    The scanner will require a2 digit supplement bescanned when an EAN-13code begins with 977.

    1 0 1 3 0 4

    The scanner will notrequire a 2 digit supplementbe scanned whenever anEAN-13 code begins with977.

    Enable 378/379 FrenchSupplement Requirement

    * Disable 378/379 FrenchSupplemental Requirement

    1 0 1 3 1 3 1 0 1 3 0 3

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    44/210

    Supplements B 4

    SECTION B SUPPLEMENTS

    Enable 434/439 GermanSupplemental Requirement

    * Disable 434/439

    German SupplementalRequirement

    1 0 1 4 1 5 1 0 1 4 0 5

    Enable 414/419 GermanSupplemental Requirement

    * Disable 414/419 GermanSupplemental Requirement

    1 0 1 4 1 3 1 0 1 4 0 3

    Enable # System 2 RequiresSupplements

    * Disable # System 2Requires Supplements

    1 0 1 4 1 2 1 0 1 4 0 2

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    45/210

    Supplements B 5

    SECTION B SUPPLEMENTS

    Enable # System 5 RequiresSupplements

    * Disable # System 5Requires Supplements

    1 0 1 2 1 5 1 0 1 2 0 5

    Enable 8711685 Requires5-Digit Supplement

    * Disable 8711685Requires 5-DigitSupplement

    1 0 7 6 1 3

    The scanner will require a5-digit supplement to be

    scanned when an EAN-13code begins with 8711685.

    This feature is notavailable with allmodels.

    1 0 7 6 0 3

    The scanner will not requirea 5-digit supplement to be

    scanned when an EAN-13code begins with 8711685.

    Enable CouponCode 128

    * Disable CouponCode 128

    1 0 0 3 1 5 1 0 0 3 0 5

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    46/210

    Supplements B 6

    SECTION B SUPPLEMENTS

    Enable Code 128 ]C1

    Extended Code Format

    * Disable Code 128 ]C1

    Extended Code Format

    1 0 1 4 1 1

    The scanner will transmit a

    ]C1 at the beginning of thecode 128 portion of thecoupon code.

    1 0 1 4 0 1

    The scanner will not

    transmit a ]C1 at thebeginning of the code 128portion of the coupon code.

    Enable 128 GroupSeparators

    * Disable 128 GroupSeparators

    1 0 1 4 1 4

    GS (1DH) character will betransmitted with couponCode 128 codes.

    1 0 1 4 0 4

    GS (1DH) character willnot be transmitted withcoupon Code 128 codes.

    * 100 msec to FindSupplemental

    200 msec to FindSupplemental

    3 0 1 3 1 0

    The scanner will allot 100milliseconds to find an addon after a main UPC/EANbar code has been scanned.

    3 0 1 3 2 0

    The scanner will allot 200milliseconds to find an addon after a main UPC/EANbar code has been scanned.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    47/210

    Supplements B 7

    SECTION B SUPPLEMENTS

    400 msec to FindSupplemental

    3 0 1 3 4 0

    The scanner will allot 400milliseconds to find an addon after a main UPC/EANbar code has been scanned.

    Enable Code IDs with

    Supplements

    * Disable Code IDs with

    Supplements

    1 0 1 2 1 4 1 0 1 2 0 4

    Allow 2/5 on 977 Bar Code Allow 2 on 977 Bar Code

    1 2 4 8 1 1

    This feature allows either2 or 5 digit supplements if

    977 mode is active.

    1 2 4 8 0 1

    This feature allows 2 digitsupplements if 977 mode is

    active.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    48/210

    Supplements B 8

    SECTION B SUPPLEMENTS

    * Beep Once on

    Supplements

    Beep twice on

    Supplements

    1 1 8 4 0 6 1 1 8 4 1 6

    Enable ISBN Check DigitTransmission

    Disable ISBN Check DigitTransmission

    1 0 1 3 1 5

    This feature is notavailable with allmodels.

    1 0 1 3 0 5

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    49/210

    Supplements B 9

    SECTION B SUPPLEMENTS

    Enable Bookland toISBN Conversion

    * Disable Bookland toISBN Conversion

    1 0 1 3 1 7

    This feature is notavailable with allmodels.

    1 0 1 3 0 7

    EnableISBN Re-Formatting

    * DisableISBN Re-Formatting

    1 0 1 3 1 6

    This feature is notavailable with allmodels.

    1 0 1 3 0 6

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    50/210

    Supplements B 10

    SECTION B SUPPLEMENTS

    Enable ISSN Check Digit

    Transmission

    * Disable ISSN Check Digit

    Transmission

    1 1 5 1 1 5 1 1 5 1 0 5

    EnableISSN Re-Formatting

    * DisableISSN Re-Formatting

    1 1 5 1 1 6

    Transmit a hyphen with thebarcode.

    1 1 5 1 0 6

    Enable 977 to

    ISSN Conversion

    * Disable 977 to

    ISSN Conversion

    1 1 5 1 1 7

    Convert 977 periodicals to

    ISSN format.

    1 1 5 1 0 7

    Do not convert 977

    periodicals to ISSN format.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    51/210

    Supplements B 11

    SECTION B SUPPLEMENTS

    Enable Number System 4Coupon Code 128

    * Disable Number System4 Coupon Code 9128

    1 0 1 0 1 2

    Supports Coupon Code 128for Number System 4 barcodes.

    1 0 1 0 0 2

    Enable UPC Discard * Disable UPC Discard

    1 0 1 0 1 3

    Supports UPC discard if theCode 128 portion of theCoupon Code 128 is

    scanned.

    1 0 1 0 0 3

    Allow Supplements andUPC in Same Line

    Disable Supplements andUPC in Same Line

    1 0 1 0 1 4

    This feature requires2 digit supplements beenabled as well asrequired redundancyand supplements.

    1 0 1 0 0 4

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    52/210

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    53/210

    Communications C 1

    SECTION C COMMUNICATIONS

    * Enable RS-232 Load Keyboard WedgeDefaults

    4 1 5 5 5 4

    The scanner will work with

    RS-232 12V serial output.

    9 9 9 9 9 4

    Scan this before selectingNormal or Stand AloneMode.

    Enable Light Pen/WandCommunication

    Enable Keyboard WedgeEmulation

    4 1 5 5 2 4

    Use this option if a scanneris used in place of a lightpen.

    5 1 5 5 1 4 3

    Select if the scannerprovides keyboardemulation by converting thescanned bar code data tothe PC keyboard scan codeequivalent.

    Enable Stand-AloneKeyboard Scanner

    5 1 5 5 1 5 3

    Allows the scanner to beused without an external

    keyboard.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    54/210

    Communications C 2

    SECTION C COMMUNICATIONS

    Load OCIA Defaults Enable OCIA Output

    9 9 9 9 9 3

    Scan this before selectingEnable OCIA output.

    4 1 5 5 4 4

    Select this option if thecommunications

    requirement is an OpticallyCoupled Interface Adapter(OCIA). This is a docked(by the host) serial interface.

    LoadIBM 46xx Defaults

    Enable IBM 46xxCommunication

    9 9 9 9 9 5

    Scan this before selectingEnable IBM 46xxCommunication

    4 1 5 5 0 4

    Select this option for IBM46xx SIOC/RS485communications.

    Not all scannerssupport this interface.The correct interfaceboard is required.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    55/210

    Communications C 3

    SECTION C COMMUNICATIONS

    Load Low SpeedExternalUSB Defaults

    EnableLow Speed USB

    9 9 9 9 7 8

    Refer to Section P forfull speed USB options.

    4 1 5 5 1 1 4

    Load Low SpeedInternalUSB Defaults

    EnableNo Communication Mode

    9 9 9 9 4 1 4 1 5 5 3 4

    Select this option if thescanner does notinterfacewith the host device.

    Reserved Reserved

    4 1 5 5 6 4 9 1 7 5 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    56/210

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    57/210

    Scanner Operation D 1

    SECTION D CONFIGURATION MODE OPTIONS

    Allow Configuration Modeon Power-Up

    * Allow Configuration ModeAnytime

    1 1 8 1 1 7

    The scanner can only enterMetroSetmode before anybar codes are scanned.

    1 1 8 1 0 7

    Allow MetroSetconfiguration at any time.

    Allow Configuration Codeson Power Up * Allow ConfigurationCodes Anytime

    1 1 8 1 1 6

    Once a product bar code isscanned after power-up, thescanner will not acceptconfiguration bar codes.

    1 1 8 1 0 6

    Allows scanning ofconfiguration bar codes anytime.

    EnableSingle Code Configuration

    DisableSingle Code Configuration

    1 1 8 2 1 2 1 1 8 2 0 2

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    58/210

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    59/210

    Scanner Operation D 3

    SECTION D SCAN BUFFERS

    5 Scan Buffers 6 Scan Buffers

    3 1 8 0 4 0

    Same function as 2 Scan

    Buffers, but 5 bar codes arein the scan field.

    3 1 8 0 5 0

    Same function as 2 Scan

    Buffers, but 6 bar codes arein the scan field.

    7 Scan Buffers 8 Scan Buffers

    3 1 8 0 6 0

    Same function as 2 ScanBuffers, but 7 bar codes arein the scan field.

    3 1 8 0 7 0

    Same function as 2 ScanBuffers, but 8 bar codes arein the scan field.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    60/210

    Scanner Operation D 4

    SECTION D REDUNDANT SCANS

    * 0 Redundant Scans 1 Redundant Scans

    3 0 1 1 0 0

    Requires 1 good decode fora good scan.

    3 0 1 1 1 0

    Requires 2 consecutivedecodes of the same bar

    code data for a good scan.

    2 Redundant Scans 3 Redundant Scans

    3 0 1 1 2 0

    Requires 3 consecutivedecodes of the same barcode data for a good scan.

    3 0 1 1 3 0

    Requires 4 consecutivedecodes of the same barcode data for a good scan.

    4 Redundant Scans 5 Redundant Scans

    3 0 1 1 4 0

    Requires 5 consecutivedecodes of the same barcode data for a good scan.

    3 0 1 1 5 0

    Requires 6 consecutivedecodes of the same barcode data for a good scan.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    61/210

    Scanner Operation D 5

    SECTION D REDUNDANT SCANS

    6 Redundant Scans 7 Redundant Scans

    3 0 1 1 6 0

    Requires 7 consecutive

    decodes of the same barcode data for a good scan.

    3 0 1 1 7 0

    Requires 8 consecutive

    decodes of the same barcode data for a good scan.

    In-Store Redundancy* Disable In-Store

    Redundancy

    1 0 1 1 1 7

    Enable redundancy ofEAN-13 Sys2 & UPCA sys2& Sys4 (store printedbarcodes).

    1 0 1 1 0 7

    Disable redundancy ofEAN-13 Sys2 & UPCA sys2& Sys4 (store printedbarcodes).

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    62/210

    Scanner Operation D 6

    SECTION D MISCELLANEOUS DECODE FEATURES

    * Enable Segmented

    UPC Decoding

    Disable Segmented

    UPC Decoding

    1 0 1 1 1 3

    Enabling segmented UPCdecoding aids in decipheringdamaged or incomplete barcodes.

    1 0 1 1 0 3

    Disable this feature whenbar codes are in goodreading condition. This willspeed up decoding andimprove over all accuracy.

    * Enable

    Piece In-Store Bar Codes

    Disable

    Piece In-Store Bar Codes

    1 0 0 9 0 7

    Enable piece EAN-13 Sys2,

    and UPCA Sys2 and Sys4(store printed barcodes).

    1 0 0 9 1 7

    Disable piece EAN-13 Sys2,

    and UPCA Sys2 and Sys4(store printed barcodes).

    OptionalSame Symbol Check

    * NormalSame Symbol Check

    1 1 8 1 1 3

    Requires 1 differentcharacter betweensuccessive bar codes toconsider the bar code new.

    1 1 8 1 0 3

    Requires 3 differentcharacters betweensuccessive bar codes toconsider the bar code new.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    63/210

    Scanner Operation D 7

    SECTION D DEPTH OF FIELD ADJUSTMENTS

    Do not change these settings unless instructed by a Metrologic representative.

    * Optimize forLow Density Codes

    Optimize forHigh Density Codes

    4 1 8 7 9 0 4 1 8 7 1 3 0

    Fixed forHigh Density Codes

    Fixed forMedium Density Codes

    4 1 8 7 0 0 4 1 8 7 1 0

    Fixed forLow Density Codes

    4 1 8 7 2 0

    For use withomnidirectionalscanners only.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    64/210

    Scanner Operation D 8

    SECTION D SAME SYMBOL TIME OUTS

    These numbers determine the length of time before a bar code can be rescanned after it

    is removed from the scan field. Single code fixed settings in msecs of No, 50, 100, 200,500, 1200 (1.2 sec), 2000 (2.0 sec) and infinite are available. User configurable valuescan be set in user-configurable increments of 50 msecs to 6350 msecs (6.35 sec).

    No Same Symbol Time OutSame Symbol Time Out100 msecs

    8 1 8 9 0 0 8 1 8 9 2 0

    Same Symbol Time Out200 msecs

    * Same Symbol Time Out500 msecs

    8 1 8 9 4 0 8 1 8 9 1 0 0

    Same Symbol Time Out1200 msecs

    Same Symbol Time Out2000 msecs

    8 1 8 9 2 4 0 8 1 8 9 4 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    65/210

    Scanner Operation D 9

    SECTION D SAME SYMBOL TIME OUTS

    InfiniteSame Symbol Time Out

    ~ VariableSame Symbol Time Out

    1 1 8 9 1 7

    The scanner will notrepetitively scan the samebar code.

    This optionoverrides thesymbol rescantime-outs.

    9 1 8 9 0 0

    Using the Multi-CodeMethod (on page xii), scanthis bar code and a codebyte sequence from SectionM to set the same symboltime-out duration. Valuesrange from 001 to 127(50 to 6350 msecs).

    BARCODE ABSENCE

    * Enable Bar CodeAbsence Detection

    Disable Bar CodeAbsence Detection

    1 1 8 2 0 0

    Excludes the MS2000Stratos Series.

    1 1 8 2 1 0

    Enable Stratos Bar CodeAbsence Detection

    * Disable Stratos Bar CodeAbsence Detection

    1 2 4 9 1 7

    The scan field must be freeof data for 50 millisecondsto accept a new bar code.

    1 2 4 9 0 7

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    66/210

    Scanner Operation D 10

    SECTION D LEDOPTIONS

    Flash Green LED if

    Rescan Allowed

    * Do not flash Green LED if

    Rescan Allowed

    1 1 8 3 1 3

    This indicates same symbol

    timeout has elapsed.

    1 1 8 3 0 3

    Reverse LED Functions * Normal LED Functions

    1 1 8 3 1 2

    Red = Laser OnGreen = Good Read

    1 1 8 3 0 2

    Green = Laser OnRed = Good Read

    * Enable 3rdLED Disable 3rdLED

    1 4 3 1 0 6

    Enable scanners optionalthird LED.

    This feature is notavailable with allmodels.

    1 4 3 1 1 6

    Disable scanners optionalthird LED.

    This feature is notavailable with allmodels.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    67/210

    Scanner Operation D 11

    SECTION D LEDOPTIONS

    * Laser LED High Intensity Laser LED Low Intensity

    2 4 3 1 0 0

    Laser LED Intensity is High

    or Normal.

    2 4 3 1 2 0

    Laser LED is Low Intensity

    This feature is notavailable with allmodels.

    * Scan LED High Intensity Scan LED Low Intensity

    2 4 3 1 0 2

    Scan LED Intensity is Highor Normal.

    2 4 3 1 2 2

    Scan LED Intensity is LowIntensity

    This feature is not

    available with allmodels.

    Scan LED Off Laser LED Off

    2 4 3 1 3 2

    The scan LED does notsignify barcode scanning.The LED will continue tolight for all other functions.

    This feature is notavailable with allmodels.

    2 4 3 1 3 0

    The laser LED does notsignify laser ON. The LEDwill continue to light for allother functions.

    This feature is notavailable with allmodels.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    68/210

    Scanner Operation D 12

    SECTION D BEEPER OPTIONS

    * Normal Tone Optional Tone 1

    3 1 8 5 7 5 3 1 8 5 6 5

    Optional Tone 2 Optional Tone 3

    3 1 8 5 5 5 3 1 8 5 4 5

    Optional Tone 4 Optional Tone 5

    3 1 8 5 3 5 3 1 8 5 2 5

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    69/210

    Scanner Operation D 13

    SECTION D BEEPER OPTIONS

    Optional Tone 6 No Beep

    3 1 8 5 1 5 3 1 8 5 0 5

    * Enable Good Scan Beep Disable Good Scan Beep

    1 4 1 9 0 3

    Enable good scan beep onpower up.

    1 4 1 9 1 3

    Disable good scan beep onpower up.

    * Enable ButtonBeep Controls

    Disable ButtonBeep Controls

    1 1 9 7 0 1

    This feature is notavailable with all

    models.

    1 1 9 7 1 1

    This feature is notavailable with all

    models.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    70/210

    Scanner Operation D 14

    SECTION D BEEPER OPTIONS

    Next Beep Tone Next Volume

    9 9 9 9 7 5 9 9 9 9 7 4

    * Loudest Volume 2ndLoudest Volume

    2 1 8 5 0 0 2 1 8 5 1 0

    3rdLoudest Volume No Volume

    2 1 8 5 2 0 2 1 8 5 3 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    71/210

    Scanner Operation D 15

    SECTION D BEEPER OPTIONS

    * Beep Once onSupplements Beep Twice onSupplements

    1 1 8 4 0 6 1 1 8 4 1 6

    Enable Fast Beep * Disable Fast Beep

    1 1 8 4 1 4 1 1 8 4 0 4

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    72/210

    Scanner Operation D 16

    SECTION D BEEPER OPTIONS

    Beep on BEL Command * Ignore BEL Command

    1 1 8 4 1 7

    The scanner beeps when itreceives a BEL character

    from the host. If a numberis sent within 200 msecsbefore the BEL character,then the scanner will beepthat number of times.

    1 1 8 4 0 7

    Enable Light Pen ToggleDuring Beep

    * Disable Light Pen ToggleDuring Beep

    1 1 6 9 1 3

    The scanner will beep andtoggle the light pen data lineon a successful decode.This drives a good readindicator.

    1 1 6 9 0 3

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    73/210

    Scanner Operation D 17

    SECTION D INTER-CHARACTERDATA TRANSMISSION DELAYS

    Use these codes to select the amount of delay between sending data characters andBar Code records from the scanner to the host. This helps prevent the scanner fromoverflowing host input buffers.

    * 1 msecInter-Character Delay

    10 msecInter-Character Delay

    8 1 8 8 1 0 8 1 8 8 1 0 0

    25 msec

    Inter-Character Delay~ Variable msec

    Inter-Character Delay

    8 1 8 8 2 5 0 9 1 8 8 0 0

    Scan this bar code and asequence of code bytes inSection M to set the delaybetween characters sent tothe host system. Delayrange can be set from 1 to255 msecs.Refer to the Multi-CodeConfiguration Method onpage xii.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    74/210

    Scanner Operation D 18

    SECTION D INTER-CHARACTERDATA TRANSMISSION DELAYS

    No Inter-Character Delay

    8 1 8 8 0 0

    INTER-RECORD DATA TRANSMISSION DELAYS

    ~ VariableInter-Record Delay

    9 1 9 3 0 0

    Turn Off Laser DuringInter-Record Delay

    * Leave Laser On DuringInter-Record Delay

    1 1 9 3 1 7 1 1 9 3 0 7

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    75/210

    Scanner Operation D 19

    SECTION D COMMUNICATION TIME OUT OPTIONS

    EnableCommunications Time Outs

    * Disable CommunicationsTime Outs

    1 1 8 4 1 2 1 1 8 4 0 2

    * Beep Before Transmit Beep After Transmit

    1 1 8 4 1 3

    Scanner will beep beforeeach label is transmitted.

    1 1 8 4 0 3

    Scanner will beep after eachlabel is transmitted.

    ~ Variable CommunicationsTime Out

    * Default CommunicationsTime Out (2 secs)

    9 1 9 1 0 0 8 1 9 1 4 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    76/210

    Scanner Operation D 20

    SECTION D COMMUNICATION TIME OUT OPTIONS

    Short Communications Time

    Out (1 sec)

    Long Communications

    Time Out (4 secs)

    8 1 9 1 2 0 0 8 1 9 1 8 0 0

    Three Beeps on Time Out * No Beeps on Time Out

    1 1 8 4 1 0 1 1 8 4 0 0

    Razzberry Tone onTime Out

    * No Razzberry Toneon Time Out

    1 1 8 4 1 1 1 1 8 4 0 1

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    77/210

    Scanner Operation D 21

    SECTION D HOST SCANNER COMMANDS

    Enable D/E Disable Command* Disable D/E Disable

    1 1 8 0 1 5

    The scanner will disable scanningafter it receives and ASCII Dfrom the host device. It willenable scanning when it receivesan ASCII E.

    1 1 8 0 0 5

    Do not monitor D/Ecommands.

    Enable Z/R Type

    D/E Simulation

    * No Z/R Type

    D/E Simulation

    1 1 8 2 1 1

    The scanner will disable scanning

    after it receives an ASCII Z fromthe host device. It will enablescanning when it receives an

    ASCII R.

    1 1 8 2 0 1

    Do not monitor Z/R

    commands.

    Enable F/L Laser Command* Disable F/L Laser

    Command

    1 1 8 0 1 4

    The scanner will turn off the laserafter receiving an ASCII Fcharacter. The laser will turn onafter it receives an ASCII Lcharacter.

    1 1 8 0 0 4

    Do not monitor F/Lcommands.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    78/210

    Scanner Operation D 22

    SECTION D HOST SCANNER COMMANDS

    Motor On/Off Using

    M/O Commands

    * Disable M/O

    Commands

    1 1 8 2 1 3

    The scanner will turn the

    motor OFF after it receives anASCII O character. Themotor will turn ON after thescanner receives an ASCIIM character.

    For use with omnidirectionalscanners only.

    1 1 8 2 0 3

    Do not monitor the M/O

    commands.

    Enable I Command Disable I Command

    1 1 5 9 1 7 1 1 5 9 0 7

    Enable i Command Disable i Command

    1 1 5 9 1 6 1 1 5 9 0 6

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    79/210

    Scanner Operation D 23

    SECTION D HOST SCANNERCOMMANDS

    Enable S Command * Disable SCommand

    1 2 5 6 1 0 1 2 5 6 0 0

    Enable EM Commands * Disable EM Commands

    1 2 0 6 1 0

    Enable EM command. Endof Medium (ctrl Y). The EMcommand sends and IDstring then a scanner statusspread over two bytes.

    1 2 0 6 0 0

    Enable SI/SO Command Disable SI/SO Command

    1 2 5 0 1 4 1 2 5 0 0 4

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    80/210

    Scanner Operation D 24

    SECTION D HOST SCANNER COMMANDS

    Use

    DTR Scan Disable

    * Do not use

    DTR Scan Disable

    1 1 8 1 1 5

    The scanner will monitor the

    DTR input to determine ifscanning should be allowed. A+12V active level enablesdecoding. A -12V inactive leveldisables decoding.

    1 1 8 1 0 5

    Do not monitor the DTR

    input.

    Enable Pass Through Disable Pass Through

    1 2 4 7 1 1

    The AUX scanner mustbe configured for the

    same Baud rate as thehost, with STX prefix,Nixdorf ID characters andCR Terminator enabled.

    1 2 4 7 0 1

    * Blink LEDs on Disable No Blink LEDs on Disable

    1 2 0 4 0 2

    When using CTS scan disable orDTR disable, blink the LEDs thatsignify the unit is disabled(signal = off).

    1 2 0 4 1 2

    When using CTS scanenable or DTR disable, donot blink the LEDs thatsignify the unit is disabled(signal = off).

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    81/210

    Scanner Operation D 25

    SECTION D HOST SCANNER COMMANDS

    Activate on DC2 Character* Do Not Activate on DC2

    Character

    1 1 8 1 1 0 1 1 8 1 0 0

    Transmit NO READ ifDC2 Activated Do Not Transmit NOREAD if DC2 Activated

    1 1 8 1 1 1 1 1 8 1 0 1

    No Green LED DuringNO READ Xmit

    * Green LED DuringNO READ Xmit

    1 1 8 3 1 1 1 1 8 3 0 1

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    82/210

    Scanner Operation D 26

    SECTION D POWER SAVE MODES

    Always Power Save Mode No Power Save Mode

    1 1 8 6 1 7

    The scanner enters powersave mode immediately

    after power-up and aftereach bar code scanned.

    For use withomnidirectionalscanners only.

    8 1 8 6 0 0

    The scanner will never enterpower save mode.

    Power Save Mode in1 minute

    Power Save Mode in2 minutes

    8 1 8 6 1 0

    The scanner enters powersave mode when the

    scanner remains idle for1 min.

    8 1 8 6 2 0

    The scanner enters powersave mode if the scanner

    remains idle for 2 min.

    Power Save in 5 Minutes Power Save in 10 Minutes

    8 1 8 6 5 0

    The scanner enters powersave mode if the scannerremains idle for 5 min.

    8 1 8 6 1 0 0

    The scanner enters powersave mode if the scannerremains idle for 10 min.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    83/210

    Scanner Operation D 27

    SECTION D POWER SAVE MODES

    Power Save in 20 Minutes Power Save in 30 Minutes

    8 1 8 6 2 0 0

    The scanner enters power

    save mode if the scannerremains idle for 20 min.

    For use with omnidirectionalscanners only.

    8 1 8 6 3 0 0

    The scanner enters power

    save mode if the scannerremains idle for 30 min.

    DefaultPower Save Mode

    BlinkPower Save Mode

    3 1 9 4 0 0

    This feature is notavailable with all

    models.

    Some Metrologic scanners

    automatically wake or exitfrom the power save modeif the IR detects movement.Other Metrologic scannerswake if their multi-FunctionButton is pressed. Pleaserefer to the Installation andUsers Guide specific toeach product.

    3 1 9 4 1 0

    The laser Blinks OFF & ONafter a configured period of

    non-use.

    When the scannerrecognizes a bar code it willexit the blink mode.

    This feature is notavailable with allmodels.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    84/210

    Scanner Operation D 28

    SECTION D POWER SAVE MODES

    Laser OFF

    Power Save Mode

    Laser Motor OFF

    Power Save Mode

    3 1 9 4 2 0

    The laser turns OFF after

    a configured period ofnon-use.

    This feature is notavailable with allmodels.

    3 1 9 4 3 0

    The laser and motor turns

    OFF after a configuredperiod of non-use.

    This feature is notavailable with allmodels.

    Dual #1Power Save Mode

    Dual #2Power Save Mode

    3 1 9 4 4 0

    The laser blinks OFF & ONafter a configured period ofnon-use then the laser andmotor turn OFF at thirty-minute intervals.

    Example 1:Example of Dual #1 PowerSave Mode with the power

    save timeout set to15 minutes.

    This feature is notavailable with allmodels.

    Some Metrologic scannersautomatically wake or exitfrom the power save modeif the IR detects movement.Other Metrologic scanners

    wake if their multi-FunctionButton is pressed. Pleaserefer to the Installation andUsers Guide specific toeach product.

    3 1 9 4 6 0

    The laser turns OFF after aconfigured period of non-use then the motor turnsOFF at thirty-minuteintervals.

    Example 2:Example of Dual #2 PowerSave Mode with the power

    save timeout set to15-minutes.

    This feature is notavailable with allmodels.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    85/210

    Scanner Operation D 29

    SECTION D POWER SAVE MODES

    * EnablePower Save Switch

    DisablePower Save Switch

    1 1 9 7 0 0

    This feature is notavailable with allmodels.

    1 1 9 7 1 0

    This feature is notavailable with allmodels.

    EnableWake with Switch Only

    * EnableWake with IR or Switch

    1 1 9 7 1 7

    Only wake from power saveusing the multi-functionbutton

    1 1 9 7 0 7

    Wake using the IR or themultifunction button.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    86/210

    Scanner Operation D 30

    SECTION D JAPANESE DOUBLE FIELD SUPPORT

    To support Japanese Double Field Bar Codes, first make sure you have your scanner configured to

    the following settings. Disable Segmented UPC Decoding Enable 2 scan buffers Disable bar code absence detection Enable normal code selects

    Then, scan the EnableJapan 2 Fieldbar code.

    Enable Japan 2 Field * Disable Japan 2 Field

    1 2 4 7 1 3 1 2 4 7 0 3

    Next, select the matching bar codes that are used for double field symbols.Note that only UPC/EAN bar codes are allowed in double field mode.

    Select at least two characters for each bar code. The maximum is 4 upper and 4 lower bar codes.EXAMPLE

    To select 54 as the first two characters in the Upper Code pair 1:1. Scan the Upper Code 1 Character 1bar code (shown on page D 31)2. Determine the correct Code Byte Value for the character 5 in 54

    (Refer to Section Ms ASCII Reference Table, starting on page M 6)a. Scan Code Byte 0b. Scan Code Byte 5c. Scan Code Byte 3

    3. Scan the Upper Code 1 Character 2bar code (shown on page D 31)4. Determine the correct Code Byte Value for the character 4 in 54.

    a. Scan Code Byte 0b. Scan Code Byte 5c. Scan Code Byte 2

    To select 18 as the first two characters in the Lower Code pair 1:1. Scan the Lower Code 1 Character 1bar code (shown on page D 31)2. Determine the correct Code Byte Value for the character 1 in 18

    (refer to Section Ms ASCII Reference Table starting on page M 6)a. Scan Code Byte 0b. Scan Code Byte 4c. Scan Code Byte 9

    3. Scan the Lower Code 1 Character 2bar code (shown on page D 31)4. Determine the correct Code Byte Value for the character 8 in 18.

    (Refer to Section Ms ASCII Reference Table, starting on page M 6)a. Scan Code Byte 0b. Scan Code Byte 5c. Scan Code Byte 6

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    87/210

    Scanner Operation D 31

    SECTION D JAPANESE DOUBLE FIELD SUPPORT

    Upper Code 1 Character 1 Upper Code 1 Character 2

    9 3 0 0 0 0 9 3 0 1 0 0

    Lower Code 1 Character 1 Lower Code 1 Character 2

    9 3 0 2 0 0 9 3 0 3 0 0

    Upper Code 2 Character 1 Upper Code 2 Character 2

    9 3 0 4 0 0 9 3 0 5 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    88/210

    Scanner Operation D 32

    SECTION D JAPANESE DOUBLE FIELD SUPPORT

    Lower Code 2 Character 1 Lower Code 2 Character 2

    9 3 0 6 0 0 9 3 0 7 0 0

    Upper Code 3 Character 1 Upper Code 3 Character 2

    9 3 0 8 0 0 9 3 0 9 0 0

    Lower Code 3 Character 1 Lower Code 3 Character 1

    9 3 1 0 0 0 9 3 1 1 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    89/210

    Scanner Operation D 33

    SECTION D JAPANESE DOUBLE FIELD SUPPORT

    Upper Code 4 Character 1 Upper Code 4 Character 2

    9 3 1 2 0 0 9 3 1 3 0 0

    Lower Code 4 Character 1 Lower Code 4 Character 2

    9 3 1 4 0 0 9 3 1 5 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    90/210

    Scanner Operation D 34

    SECTION D JAPANESE DOUBLE FIELD SUPPORT

    Japanese Trial Time Enable Code Selects

    9 3 8 8 0 0

    Scan the above bar code followed bythe 3 code bytes in Section M that

    represent the timeout value desired if inspecial code select mode.

    1 is equal to 100 milliseconds

    Example:If a 500 millisecond timeout is desired,scan the above code followed by codebyte 0, code byte 0 and code byte 5.

    1 1 8 2 1 7

    Transmit Top Code Select* Transmit

    All Code Selects

    1 2 0 4 1 0

    Transmit the highest priority code selectif all are not found.

    1 2 0 4 0 0

    Transmit all code selects.

    Enable Error Tone * Disable Error Tone

    1 1 8 5 1 3

    Adds ability to sound RAZZ error tonewhen special code selects fail.

    1 1 8 5 0 3

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    91/210

    Scanner Operation D 35

    SECTION D TEST MODES

    Scanability ON * Scanability OFF

    1 1 8 0 1 7

    The scanner will enter

    scanability test mode.

    Do not enableunless instructed toby a Metrologicrepresentative.

    1 1 8 0 0 7

    Scan Count Mode ON * Scan Count Mode OFF

    1 1 8 0 1 6

    The scanner will enter scancount test mode and the

    scanners firmware numberwill transmit to the host.

    Do not enableunless instructed toby a Metrologicrepresentative.

    1 1 8 0 0 6

    Temporary Symbologies

    The Temporary Symbologiestest

    code enables all major types of barcode symbologies, reduces theminimum number of charactersrequired to 1, sets the minimum ITFcharacters required to 2, and addsthe symbology name as a prefix tothe transmission. This feature isdisabled when power to thescanner is cycled OFFand ON.

    9 9 8 0 4 1

    Do not enableunless instructed toby a Metrologicrepresentative

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    92/210

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    93/210

    Prefixes/Suffixes E 1

    SECTION E CONFIGURABLE PREFIXES,ALL DATA

    Scan the Enter/Exit Configuration Modebar code before trying to set thisfeature. Please refer to the Multi-Code method on page xii.

    Enter/ExitConfiguration Mode

    ~ Configurable PrefixCharacter #1

    9 9 9 9 9 9 9 0 3 5 0 0

    A prefix ID can be addedand assigned for datatransmission. Use this codewith a 3-code bytesequence from Section Mthat represents the desiredcharacter.

    ~ Configurable PrefixCharacter #2

    ~ Configurable PrefixCharacter #3

    9 0 3 6 0 0

    Assigns a 2ndconfigurableprefix character.

    9 0 3 7 0 0

    Assigns a 3rdconfigurableprefix character.

    ~ Configurable PrefixCharacter #4 ~ Configurable PrefixCharacter #5

    9 0 3 8 0 0

    Assigns a 4thconfigurable

    prefix character.

    9 0 3 9 0 0

    Assigns a 5thconfigurable

    prefix character.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    94/210

    Prefixes/Suffixes E 2

    SECTION E CONFIGURABLE PREFIXES,ALL DATA

    ~ Configurable Prefix

    Character #6

    ~ Configurable Prefix

    Character #7

    9 0 4 0 0 0

    Assigns a 6thconfigurable

    prefix character.

    9 0 4 1 0 0

    Assigns a 7thconfigurable

    prefix character.

    ~ Configurable PrefixCharacter #8

    ~ Configurable PrefixCharacter #9

    9 0 4 2 0 0

    Assigns a 8thconfigurableprefix character.

    9 0 4 3 0 0

    Assigns a 9thconfigurableprefix character.

    ~ Configurable PrefixCharacter #10

    * Clear all UserConfigurable Prefixes

    9 0 4 4 0 0

    9 9 9 9 8 5

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    95/210

    Prefixes/Suffixes E 3

    SECTION E CONFIGURABLE IDCHARACTERS,CODE SPECIFIC

    * Use Configurable CodeID Bytes as Prefixes

    Use Configurable Code IDBytes as Suffixes

    1 0 5 5 0 7

    User configured, codespecific ID bytes aretransmitted before the data.

    If using prefixes, userconfigured suffixescan not be used.

    1 0 5 5 1 7

    User configured, codespecific ID bytes aretransmitted after the data.

    If using suffixes, userconfigured prefixescan not be used.

    IDENTIFIERS CHARACTER

    ~ Configurable UPC-A ID ~ Configurable UPC-E ID

    9 0 5 6 0 0 9 0 5 7 0 0

    While using the Multi-Code method, scan this bar code followed by the 3 code byte barcodes in Section M that represent a unique ID character to be associated with this bar codetype. (Refer to the Multi-Code Method on page xii.)

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    96/210

    Prefixes/Suffixes E 4

    SECTION E CONFIGURABLE IDCHARACTERS,CODE SPECIFIC

    ~ Configurable EAN-8 ID ~ Configurable EAN-13 ID

    9 0 5 8 0 0

    While using the Multi-Code method,scan this bar code followed by the 3code byte bar codes in Section Mthat represent a unique ID characterto be associated with this bar codetype. (Refer to the Multi-CodeMethod on page xii.)

    9 0 5 9 0 0

    ~ Configurable Code 39 ID ~ ConfigurableCode 128 ID

    9 0 6 0 0 0 9 0 6 1 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    97/210

    Prefixes/Suffixes E 5

    SECTION E CONFIGURABLE IDCHARACTERS,CODE SPECIFIC

    ~ Configurable Code 93 ID ~ Configurable Code 11 ID

    9 0 6 3 0 0

    While using the Multi-Code method,scan this bar code followed by the 3code byte bar codes in Section Mthat represent a unique ID characterto be associated with this bar codetype. (Refer to the Multi-CodeMethodon page xii.)

    9 0 6 4 0 0

    ~ Configurable Telepen ID ~ Configurable

    TRI-OPTIC ID

    9 0 6 2 0 0 9 0 7 2 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    98/210

    Prefixes/Suffixes E 6

    SECTION E CONFIGURABLE IDCHARACTERS,CODE SPECIFIC

    ~ Configurable

    Standard 2 of 5 ID

    ~ Configurable

    Interleaved 2 of 5 ID

    9 0 7 1 0 0

    While using the Multi-Code method,scan this bar code followed by the 3code byte bar codes in Section Mthat represent a unique ID characterto be associated with this bar codetype. (Refer to the Multi-CodeMethod on page xii.)

    9 0 6 7 0 0

    ~ ConfigurableMatrix 2 of 5 ID ~ ConfigurableAirline 2 of 5 ID

    9 0 6 8 0 0 9 0 6 9 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    99/210

    Prefixes/Suffixes E 7

    SECTION E CONFIGURABLE IDCHARACTERS CODE SPECIFIC

    ~ ConfigurableMSI Plessey ID

    ~ ConfigurableUK Plessey ID

    9 0 6 5 0 0

    While using the Multi-Code method,scan this bar code followed by the 3code byte bar codes in Section Mthat represent a unique ID characterto be associated with this bar codetype. (Refer to the Multi-CodeMethod on page xii.)

    9 0 7 0 0 0

    ~ ConfigurableCodabar ID

    * Clear all ConfigurableCode Specific IDs

    9 0 6 6 0 0 9 9 9 9 8 3

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    100/210

    Prefixes/Suffixes E 8

    SECTION E STANDARD PREFIX CHARACTERS

    Enable STX Prefix * Disable STX Prefix

    1 1 6 6 1 5

    The scanner will transmit aStart of TeXt (ASCII 02H)

    before each bar code.

    1 1 6 6 0 5

    Will not transmit a Start ofTeXt (ASCII 02H) before

    each bar code.

    EnableRockford-Thompson Mode

    * Disable Rockford-Thompson Mode

    1 0 5 5 1 3 1 0 5 5 0 3

    Enable AIM ID Characters* Disable AIM ID

    Characters

    1 0 7 9 1 5

    The scanner will transmitAIM symbology identifiers.

    Some scannermodels may notsupport this feature.

    1 0 7 9 0 5

    The scanner will nottransmit AIM symbologyidentifiers.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    101/210

    Prefixes/Suffixes E 9

    SECTION E STANDARD PREFIX CHARACTERS

    Enable UPC Prefix ID * Disable UPC Prefix ID

    1 1 6 6 1 7

    When enabled, the scanner

    will transmit a prefix beforeany UPC/EAN bar code.

    The prefixes are as follows:A (UPC-A),E0 (UPC-E),F (EAN-13), andFF (EAN-8).

    1 1 6 6 0 7

    Do not send prefix ID

    Characters with UPC/EANcodes.

    Enable NCR Prefix ID * Disable NCR Prefix ID

    1 0 7 9 1 1

    When enabled, the scannerwill transmit a prefix beforethe following code types.

    The prefixes are as follows:

    1 0 7 9 0 1

    A (UPC-A),E0 (UPC-E),FF (EAN-8),F (EAN-13),B1 (Code 39),B2 (ITF) andB3 (Code 128 & other codes).

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    102/210

    Prefixes/Suffixes E 10

    SECTION E STANDARD PREFIX CHARACTERS

    Enable Nixdorf ID

    Characters

    * Disable Nixdorf ID

    Characters

    1 0 7 9 1 7

    This option transmits code

    identifiers before each barcode for manySiemens/Nixdorf registers.

    1 0 7 9 0 7

    This option will not transmit

    Siemens/Nixdorf codeidentifiers.

    Enable SANYO IDCharacters

    * Disable SANYO IDCharacters

    1 0 7 9 1 6

    Transmit Sanyo IDCharacters.

    1 0 7 9 0 6

    Do not transmit Sanyo IDCharacters.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    103/210

    Prefixes/Suffixes E 11

    SECTION E STANDARD PREFIX CHARACTERS

    Enable TEC RegisterFormat ID Characters

    Disable TEC RegisterFormat ID Characters

    1 2 4 7 1 0 1 2 4 7 0 0

    Enable TEC MA1530ID Characters

    Disable TEC MA1530ID Characters

    1 0 8 0 1 0 1 0 8 0 0 0

    Enable Symbology Prefix Disable Symbology Prefix

    1 0 5 5 1 4

    This option adds asymbology description infront of the bar codetransmission.

    1 0 5 5 0 4

    Do not add a symbologydescription in front of the barcode transmission.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    104/210

    Prefixes/Suffixes E 12

    SECTION E STANDARD PREFIX CHARACTERS

    Enable Manufacturer

    ID Prefix

    * Disable Manufacturer

    ID Prefix

    1 0 5 5 1 2

    Transmits METROLOGIC

    before all bar code data toidentify the scanner as aMetrologic Scanner.

    1 0 5 5 0 2

    The scanner will not

    transmit the manufactureridentification string.

    Enable C Prefix * Disable C Prefix

    1 0 5 5 1 1 1 0 5 5 0 1

    Enable $ Prefix ID

    for UPC/EAN

    * Disable $ Prefix ID

    for UPC/EAN

    1 0 5 5 1 0 1 0 5 5 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    105/210

    Prefixes/Suffixes E 13

    SECTION E STANDARD PREFIX CHARACTERS

    Enable Tab Prefix * Disable Tab Prefix

    1 1 6 6 1 1

    The scanner will transmit a

    TAB (ASCII 09H) beforeeach bar code.

    1 1 6 6 0 1

    The scanner will not

    transmit a TAB.

    Enable SNI Beetle Mode * Disable SNI Beetle Mode

    1 1 6 1 1 1 1 1 6 1 0 1

    Enable Cipher 1021 IDs * Disable Cipher 1021 IDs

    1 1 6 1 1 3 1 1 6 1 0 3

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    106/210

    Prefixes/Suffixes E 14

    SECTION E STANDARD SUFFIX CHARACTERS

    * Enable CR Suffix Disable CR Suffix

    1 1 6 6 1 3

    The scanner will transmit aCarriage Return after each

    bar code.

    1 1 6 6 0 3

    The scanner will nottransmit a Carriage Return

    after each bar code.

    * Enable LF Suffix Disable LF Suffix

    1 1 6 6 1 2

    The scanner will transmit aLine Feed after each barcode.

    This feature isDisabled whenkeyboard wedgedefaults are loaded.

    1 1 6 6 0 2

    The scanner will nottransmit a Line Feed aftereach bar code.

    Enable Tab Suffix * Disable Tab Suffix

    1 1 6 6 1 0

    The scanner will transmit aTAB (ASCII 09H) after eachbar code.

    1 1 6 6 0 0

    The scanner will nottransmit a TAB (ASCII 09H)after each bar code.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    107/210

    Prefixes/Suffixes E 15

    SECTION E STANDARD SUFFIX CHARACTERS

    Enable ETX Suffix * Disable ETX Suffix

    1 1 6 6 1 4

    The scanner will transmit

    End of TeXt (ASCII 03H)after the bar code data.

    1 1 6 6 0 4

    The scanner will not

    transmit End of TeXt(ASCII 03H).

    Enable UPC Suffix ID * Disable UPC Suffix ID

    1 1 6 6 1 6

    The scanner will transmit asuffix after any UPC/EANbar code.

    The suffixes are as follows:A (UPC-A),E (UPC-E),F (EAN-13) and

    F (EAN-8).

    1 1 6 6 0 6

    The scanner will nottransmit a suffix afterUPC/EAN bar codes.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    108/210

    Prefixes/Suffixes E 16

    SECTION E LONGITUDINAL REDUNDANCY CHECK (LRC)

    Enable Transmit of

    LRC Calculation

    * Disable Transmit of

    LCR Calculation

    1 0 7 8 1 1

    The scanner outputs an

    LRC check character afterthe bar code.

    1 0 7 8 0 1

    The scanner will not output

    an LRC (check character)after the bar code.

    * Start LRC on First Byte Start LRC on Second Byte

    1 0 7 8 0 0

    The scanner will calculatethe LRC check digit startingwith the first character.

    1 0 7 8 1 0

    The scanner will calculatethe LRC check digit startingwith the second character.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    109/210

    Prefixes/Suffixes E 17

    SECTION E CONFIGURABLE SUFFIXES,ALL DATA

    Scan the Enter/Exit Configuration Mode bar code before trying to set this feature.Refer to the Multi-Code Method on page xii.

    Enter/ExitConfiguration Mode

    ~ Configurable SuffixCharacter #1

    9 9 9 9 9 9 9 0 4 5 0 0

    A suffix ID can be addedand assigned for datatransmission. Use this codewith a 3 code byte sequencefrom Section M thatrepresents the desiredcharacter.

    ~ Configurable Suffix

    Character #2

    ~ Configurable Suffix

    Character #3

    9 0 4 6 0 0

    Assigns a 2ndconfigurablesuffix character.

    9 0 4 7 0 0

    Assigns a 3rdconfigurablesuffix character.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    110/210

    Prefixes/Suffixes E 18

    SECTION E CONFIGURABLE SUFFIXES,ALL DATA

    ~ Configurable Suffix

    Character #4

    ~ Configurable Suffix

    Character #5

    9 0 4 8 0 0

    Assigns a 4thconfigurable

    suffix character.

    While using the Multi-Code method,scan this bar code followed by the 3code byte bar codes in Section Mthat represents the desiredcharacter. (Refer to the Multi-CodeMethod on page xii.)

    9 0 4 9 0 0

    Assigns a 5thconfigurable

    suffix character.

    ~ Configurable SuffixCharacter #6

    ~ Configurable SuffixCharacter #7

    9 0 5 0 0 0

    Assigns a 6thconfigurablesuffix character.

    9 0 5 1 0 0

    Assigns 7thconfigurablesuffix character.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    111/210

    Prefixes/Suffixes E 19

    SECTION E CONFIGURABLE SUFFIXES,ALL DATA

    ~ Configurable SuffixCharacter #8

    ~ Configurable SuffixCharacter #9

    9 0 5 2 0 0

    Assigns a 8thconfigurablesuffix character.

    9 0 5 3 0 0

    Assigns a 9thconfigurablesuffix character.

    ~ Configurable SuffixCharacter #10

    9 0 5 4 0 0

    Assigns a 10thconfigurablesuffix character.

    While using the Multi-Code method, scan thisbar code followed by the3 code byte bar codes inSection M that representthe desired character.

    (Refer to the Multi-CodeMethod on page xii.)

    * Clear All UserConfigurable Suffixes

    9 9 9 9 8 4

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    112/210

    Prefixes/Suffixes E 20

    SECTION E SPECIAL FORMATS

    Enable SINEKO Mode * Disable SINEKO Mode

    1 0 7 9 1 4 1 0 7 9 0 4

    Enable Newcode FormattingMode A

    * Disable NewcodeFormatting Mode A

    1 1 6 7 1 1 1 1 6 7 0 1

    Enable Newcode Formatting

    Mode B

    * Disable Newcode

    Formatting Mode B

    1 1 6 7 1 0 1 1 6 7 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    113/210

    Prefixes/Suffixes E 21

    SECTIONE CHARACTER REPLACEMENTS

    To replace a character:1. Scan the Enter/Exit Configuration Modebar code

    (located on page xii, at the front of this guide).

    2. Scan the Character to Replace Code (shown below).

    3. Scan the ASCII Code Byte value of the character you wish to replace

    (refer to the ASCII reference table in Section M).

    4. Scan the Replacement Characterbar code.

    5. Scan the ASCII Code Byte value of the replacement character.

    6. Scan the Enter/Exit Configuration Modebar code

    (located on page xii, at the front of this guide).

    Character to Replace No Replacement

    9 3 8 6 0 0 8 3 8 6 0 0

    Replacement Character

    9 3 8 7 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    114/210

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    115/210

    Code Formatting F 1

    SECTION F UPC/EAN

    * Transmit UPC-ACheck Digit

    Do not TransmitUPC-A Check Digit

    1 0 7 5 1 7 1 0 7 5 0 7

    Transmit UPC-E

    Check Digit

    * Do Not Transmit

    UPC-E Check Digit

    1 0 7 5 1 6 1 0 7 5 0 6

    Expand UPC-E to 12 Digits* Do Not Expand

    UPC-E To 12 Digits

    1 0 7 5 1 5

    Expand UPC-E bar codes tothe 12 digit equivalent,

    UPC-A bar codes.

    1 0 7 5 0 5

    Do not expand UPC-E to the12 digit equivalent, UPC-A

    bar code.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    116/210

    Code Formatting F 2

    SECTION F UPC/EAN

    Convert UPC-A to EAN-13

    * Do Not Convert

    UPC-A to EAN-13

    1 0 7 5 1 4

    The scanner converts

    UPC-A to EAN-13 bytransmitting a leading zerobefore the bar code.

    1 0 7 5 0 4

    The scanner will not convert

    UPC-A to EAN-13.

    Transmit Lead Zeroon UPC-E

    Do Not TransmitLead Zero on UPC-E

    1 0 7 5 1 3

    This option will transmit azero before each

    UPC-E bar code.

    1 0 7 5 0 3

    This option will not transmita zero before each UPC-E

    bar code.

    Convert EAN-8 to EAN-13* Do Not Convert

    EAN-8 to EAN-13

    1 0 7 5 1 2

    The scanner will transmitfive zeros before the barcode to convert EAN-8 toEAN-13.

    1 0 7 5 0 2

    The scanner will not convertEAN-8 to EAN-13.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    117/210

    Code Formatting F 3

    SECTION F UPC/EAN

    * Transmit UPC-ANumber System

    Do Not Transmit UPC-ANumber System

    1 0 7 5 1 1 1 0 7 5 0 1

    Metrologic stronglydiscourages usingthis feature.Duplicate numbersmay result in thedatabase.

    * TransmitUPC-A MFR #

    Do Not TransmitUPC-A MFR #

    1 0 7 6 1 1 1 0 7 6 0 1

    * TransmitUPC-A ITEM #

    Do Not TransmitUPC-A ITEM #

    1 0 7 6 1 0 1 0 7 6 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    118/210

    Code Formatting F 4

    SECTION F UPC/EAN

    * Transmit EAN-8

    Check Digit

    Do Not Transmit

    EAN-8 Check Digit

    1 0 7 9 1 0 1 0 7 9 0 0

    * Transmit EAN-13Check Digit Do Not TransmitEAN-13 Check Digit

    1 0 7 9 1 2 1 0 7 9 0 2

    GTIN-14 Format No GTIN-14 Format

    1 0 7 5 1 0

    This feature is notavailable with all

    models.

    1 0 7 5 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    119/210

    Code Formatting F 5

    SECTION F CODABAR

    Transmit Codabar Start/StopCharacters

    * Do Not Transmit CodabarStart/Stop

    1 0 7 7 1 7

    Transmits Codabars start/stopcharacters before and after eachbar code.

    1 0 7 7 0 7

    Will not transmit Codabarsstart/stop characters before andafter each bar code.

    Convert Codabar Start/Stop

    Characters to Lowercase

    * Do Not Convert CodabarStart/Stop Characters toLowercase

    1 1 5 1 1 0 1 1 5 1 0 0

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    120/210

    Code Formatting F 6

    SECTIONF CODABAR

    Enable

    CLSI Editing

    1 0 7 7 1 6

    CLSI type editing will be done

    before the information istransmitted to the host.

    This option will onlywork with 14 digitCodabar type lengths.

    * Do Not EnableCLSI Editing

    1 0 7 7 0 6

    This option will not performCLSI type editing before theinformation is transmitted tothe host.

  • 8/12/2019 MetroSelect Configuration Guide 02407H

    121/210

    Code Formatting F 7

    SECTION F CODE 39

    Enable MOD 43Check on Code 39

    * Disable MOD 43 Checkon Code 39

    1 0 0 2 1 3

    The scanner will only scanCode 39 bar codes thathave a valid Modulo 43Check Digit.

    1 0 0 2 0 3

    The scanner will not testCode 39 bar codes for aModulo 43 Check Digit.

    Transmit Mod 43

    Check Digit on Code 39*