microcoaxial surgery
DESCRIPTION
Perfect Vision's Dr Con Moshegov presentation on: Microcoaxial surgeryTRANSCRIPT
![Page 1: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/1.jpg)
The Art of Micro-coaxial Lens Replacement
Con N. Moshegov
Sydney
![Page 2: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/2.jpg)
Microincisional Phaco
Small incision clear corneal surgery is desirable because:
Causes less induced astigmatismPossibly reduces risk of endophthalmitisQuicker stabisation of final refraction Potentially better AC maintenance
Prospective evaluation of early visual and refractive effects with small clear corneal incision for cataract surgery.
Lyle WA, Jin GJC. J Cataract Refract Surg 1996; 22: 1456-60
![Page 3: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/3.jpg)
Surgically induced astigmatismSurgically induced astigmatism
![Page 4: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/4.jpg)
Microincisional PhacoMicroincisional Phaco
Two methods of microincision cataract surgery available:
Bimanual
Coaxial
![Page 5: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/5.jpg)
3 groups each of 5 human cadaver eyesUnderwent simulated phaco by– Standard phaco (2.75mm)– Bimanual phaco (2 x 1.2mm)– Microcoaxial phaco (2.2mm)
Wound integrity assessed by noting aqueous leakage and India ink penetrationWound architecture examined with SEM
![Page 6: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/6.jpg)
Microincisional PhacoMicroincisional Phaco
Spontaneous wound leakage evident in all 5 of the bimanual group, 1 of the standard group and none of the 2.2mm coaxial group
Whitening and edema of wound edge present in 4 eyes of the bimanual group and in none of the others
India ink penetrated the 1.2mm wounds of the bimanual group but not the coaxial group (India Ink particles have roughly the same size as bacteria)
Greater endothelial cell loss and compromise to Descemet’s membrane near wound in bimanual group
![Page 7: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/7.jpg)
Microincisional PhacoMicroincisional Phaco
Why so?
Stress from instrument manipulation within an overly tight wound
Increased heat from a sleeveless tip
![Page 8: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/8.jpg)
Microincisional PhacoMicroincisional Phaco
Other disadvantages of bimanual MICS:
CCC with conventional forceps not possible
Necessitates chopping technique
Necessitates irrigating chopper:– Restricted inflow → difficulty maintaining AC
![Page 9: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/9.jpg)
![Page 10: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/10.jpg)
Microincisional PhacoMicroincisional Phaco
OZil™ Torsional Technology is possible through a 2.2mm incision using ‘Ultra Sleeve’
Any single piece AcrySof IOL can now be implanted through an unenlarged 2.2mm incision
Minor alterations to usual technique required– CCC– Micro tip and Ultra sleeve– I/A– IOL implantation
![Page 11: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/11.jpg)
Microincisional PhacoMicroincisional Phaco
• Some capsulorhexis forceps cannot be Some capsulorhexis forceps cannot be opened inside the 2.4mm (or smaller) incisionopened inside the 2.4mm (or smaller) incision
![Page 12: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/12.jpg)
No good:• Masket forceps from Katena (K5-5084 & K5-5084a) • Kraff-Utrata forceps from Asico (AE-4394 & AE-4394a)
Good:Good:• Utrata from Katena (K5-5081 & K5-5081a) Utrata from Katena (K5-5081 & K5-5081a) • Inamura cross action from Duckworth & Kent (2-716-2R)Inamura cross action from Duckworth & Kent (2-716-2R)
• Vitreo-retinal micro-forceps not necessaryVitreo-retinal micro-forceps not necessary
![Page 13: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/13.jpg)
0.9 mm MicroTip
0.9 mm Flared Tip
0.9 mm Tapered Tip
![Page 14: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/14.jpg)
Optimal Tip for Micro-coaxial: 0.9 mm Mini-Flared Kelman 0.9 mm Mini-Flared Kelman®® ABS ABS®® Tips Tips
Angled design enhances OZil Angled design enhances OZil torsional movement and torsional movement and efficiencyefficiencyFlared head increases holding Flared head increases holding force and emulsification force and emulsification capacitycapacityNarrower proximal portion Narrower proximal portion permits utilization of higher permits utilization of higher vacuum and offers better vacuum and offers better surge suppressionsurge suppression
30° and 45° angulations
![Page 15: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/15.jpg)
Irrigation/aspirationIrrigation/aspiration
Smaller bore I/A tip
Silicone tip an option
Metallic tips also available
No change in technique
![Page 16: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/16.jpg)
IOL implantationIOL implantation
Not possible with ‘B’ cartridge
Modification of technique necessary with ‘C’ cartridge
Single handed injectors with second hand being used to provide countertraction
![Page 17: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/17.jpg)
![Page 18: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/18.jpg)
MONARCH® D Cartridge
Lockout Feature
33% smaller nozzle size than Monarch® C cartridge
D C
![Page 19: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/19.jpg)
~ 33% reduction vs. ‘C’ nozzle tip
BA
D
C
Monarch III ‘D’ Cartridge & H4 (blue) Injector
Monarch II ‘C’ Cartridge & H3 (green) Injector
![Page 20: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/20.jpg)
Very similar to the Very similar to the MonarchMonarch®® II (Green) Injector II (Green) Injector
Blue color for ease of identificationBlue color for ease of identification
Same ergonomic feelSame ergonomic feel
Same threads and lens advance rateSame threads and lens advance rate
Smaller plunger tip to accommodate the smaller Smaller plunger tip to accommodate the smaller MonarchMonarch®® D cartridge D cartridge
MONARCH® III Injector
![Page 21: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/21.jpg)
NEW MonarchNEW Monarch®® III IOL Delivery III IOL Delivery System* System* (INTREPID(INTREPID™ Micro-coaxial System)™ Micro-coaxial System)
• Easier IOL loading vs. Monarch ‘C’ • 2.4mm ‘through-the-wound’
•Surgeon technique similar to Monarch II with ‘C’ with larger incision
• 2.2mm wound assisted•LESS stress vs. other systems
• AcrySof IQ (SN60WF) IOL = up to 27.0D
*Commercial availability January 2008
![Page 22: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/22.jpg)
![Page 23: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/23.jpg)
Attributes of AcrySof IOL
• Tough• No haptic damage• Slow controlled unfolding• Easy to orientate
![Page 24: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/24.jpg)
Attributes of AcrySof IOL
• No tilting• Rotational stability• Blue filter • Well documented proof of low PCO
![Page 25: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/25.jpg)
Attributes of AcrySof IOL
• Same platform with all variations
![Page 26: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/26.jpg)
Toric IOL needs to be rotationally stable
![Page 27: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/27.jpg)
As the pupil changes size, its centroid may not remain stationary relative to the limbus
![Page 28: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/28.jpg)
Centration relative to the pupil
• With Acrysof single piece IOLs the surgeon can make an adjustment to the final position of the IOL
• Where the surgeon puts it is where it will stay!
![Page 29: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/29.jpg)
Almost 30 million AcrySof IOL have been implanted over the last 10 yearsOne in every two foldable IOLs implanted in the World is made of AcrySof material70% of these are single pieceMajority of these are with a blue filter
![Page 30: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/30.jpg)
Filtering Blue LightFiltering Blue Light
The AcrySof Natural lens has not been demonstrated to have any significant negative impact on colour perception, contrast sensitivity or scotopic vision
Despite theoretical concerns it has not been documented to cause a significant disruption to the circadian rhythm
No proof that filtering blue light reduces the risk of developing ARMD
![Page 31: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/31.jpg)
Retinal Protection: FACTS
Mice exposed to blue light for 25 minutes Mice exposed to blue light for 25 minutes have photoreceptor damagehave photoreceptor damage
If an AcrySof Natural lens is interposed If an AcrySof Natural lens is interposed between them and the light source…between them and the light source…
much less damage occursmuch less damage occurs
![Page 32: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/32.jpg)
Retinal Protection: FACTS
Surgeons have a marked supression of blue Surgeons have a marked supression of blue sensitivity after performing Argon laser PRP using sensitivity after performing Argon laser PRP using blue – green light blue – green light Lasts for several hoursLasts for several hoursIn more senior ophthalmologists this was In more senior ophthalmologists this was irreversibleirreversible
Gunduz, K and Arden, GB. Changes in colour contrast Gunduz, K and Arden, GB. Changes in colour contrast sensitivity associated with operating argon lasers. sensitivity associated with operating argon lasers.
Br. J. Ophthalmol 1989 (73), 241-6.
![Page 33: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/33.jpg)
‘‘Every major IOL manufacturer is
working on the idea of a blue light
filtering lens’
![Page 34: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/34.jpg)
I’ll bet…OZil™ Torsional Technology will prove to be a most popular method of phacoemulsification
Better efficiency and improved followability
Safer thermal profile
Utilized across all lens densities
Requires no change in technique
Goes well with microincisional surgery
Bimanual MICS will fall in popularity
AcrySof will maintain it’s popularity
![Page 35: Microcoaxial surgery](https://reader033.vdocument.in/reader033/viewer/2022061214/5499100cb4795962238b45f4/html5/thumbnails/35.jpg)
No financial interest in any of the products No financial interest in any of the products mentioned and no gain in endorsing themmentioned and no gain in endorsing them