microscan v5 overview.ppt - intech instruments · 1 microscan v5 s.c.a.d.a and datas.c.a.d.a and...
TRANSCRIPT
1
MicroScan V5S.C.A.D.A and dataS.C.A.D.A and data--logging logging
software and associated software and associated hardware fromhardware from
MicroScan MicroScan -- Connects toConnects to
MicroScan Software connects Analogue Inputs & OutputsMicroScan Software connects to the Intech Micro 2100 series Remote Station hardware modules to form a complete supervisory control and data acquisition system.
Analogue Inputs & OutputsDigital Inputs & Outputs
PLCs
Controllers
acqu s t o syste
2
MicroScan MicroScan -- CapabilityCapability
MicroScan combines all the basic d t l i f ti i t
Analogue Inputs & OutputsDigital Inputs & Outputsdatalogging functions into one
package and performs the function of regularly gathering information, checking alarm states - displaying the data, plus historical analysis and (MMI) operator interface.
g p p
PLCs
Controllers
RS232 to RS422/485converterPC-Networks
MicroScan is made up of the MicroScan is made up of the following main Modules:following main Modules:
Recorder Module: Real Time Trends Recorder Module: Real Time Trends D t Di lD t Di lUp to: 1320 I/OUp to: 1320 I/O Data Displays Data Displays Historical AnalysisHistorical Analysis
Mimic Module: Operator Interface Mimic Module: Operator Interface Up to: 6400 I/OUp to: 6400 I/O MMIMMIController ModuleController ModuleInterface Module: Field Remote Stations and PLC’sInterface Module: Field Remote Stations and PLC’sNetwork Module: Data SharingNetwork Module: Data SharingDDE: Link in to other Windows ApplicationsDDE: Link in to other Windows Applications
3
Page #
11The RecorderThe Recorder
The recorder forms the ‘heart’ 11Page #
2020Page #
5353Page #
8484
The recorder forms the heart of the MicroScan system.
The recorder displays up to 100 pages.
8484Page #
9595
The RecorderThe Recorder
Each page can Page 11
display up to 10 different input signals.
Analogue Inputs/ OutputsDigital Inputs/ Outputs
PLCs
Controllers
Digital Inputs/ Outputs
4
The recorder functions operates continuously including automatic logs & reports plus alarm handling and store file
The RecorderThe Recorder
reports, plus alarm handling and store file generation.
The recorder scans and loads data onto the hard disk at preset rates ensuring safe storage for later retrieval and analysis.
RecorderRecorderPowerful trendingPowerful trendingPowerful trending Powerful trending
and and Historical retrievalHistorical retrieval
5
Digital InputsDigital Inputs(On/Off Indication)(On/Off Indication)
Analogue InputsAnalogue Inputs
6
Hyperlink page Hyperlink page selection for instant selection for instant
page accesspage access
Password protection for Password protection for changes to settingschanges to settings
7
Popup Colour Popup Colour Key Index..Key Index..
..or expand ..or expand Navigation TreeNavigation Tree
8
Use The Mouse tracker Use The Mouse tracker to pinpoint times, dates to pinpoint times, dates and values of interestand values of interest
Track throughTrack throughtime and reallytime and really
see what see what happenedhappened
9
Select which Select which lines to viewlines to view
Popup Tool Bar for quick Popup Tool Bar for quick p p qp p qscale changes, printing, scale changes, printing,
measuring time & values, measuring time & values, showing/hiding inputsshowing/hiding inputs
10
Check on vital Alarm statesCheck on vital Alarm states
Alarms:Alarms:Alarms can perform the following states: Alarms can perform the following states:
Activate the PC beeperActivate the PC beeperActivate the PC beeper,Activate the PC beeper,Send an alarm text message to cell phone(s).Send an alarm text message to cell phone(s).Activate an alarm relay to:Activate an alarm relay to:
Activate an autoActivate an auto--dialler,dialler,Activate Alarm bells.Activate Alarm bells.
11
MA5: MA5: Text messages allow you to Text messages allow you to keep in touch with your processkeep in touch with your process
MA5 Examples:MA5 Examples:
12
It doesn’t have to be all graphsIt doesn’t have to be all graphsAlphaAlpha--Numeric indicationNumeric indication
Switch between Graphs and Data instantlySwitch between Graphs and Data instantlyp yp y
Choose from Choose from the Listthe List
13
Easy to follow menusEasy to follow menus
Easily view the Last Easily view the Last Pages looked atPages looked at
14
OnOn--Line HistoryLine HistoryThis is a powerful and convenient This is a powerful and convenient history viewing window. history viewing window. y gy g
Any data stored by the Recorder can be:Any data stored by the Recorder can be:retrieved and viewed in a trend format, retrieved and viewed in a trend format, exported through the Windows clipboard, or exported through the Windows clipboard, or converted to a format suitable for converted to a format suitable for
d h t d t bd h t d t bspreadsheets or databases,spreadsheets or databases,
without interrupting the Recorder!without interrupting the Recorder!
Data Movement Buttons just like a CDData Movement Buttons just like a CD--Player. Player. Move the graph window through history.Move the graph window through history.
15
Adjust the viewing window time Adjust the viewing window time scale from 5 Minute to 31 daysscale from 5 Minute to 31 days
Easy Search Easy Search FunctionFunction
16
Select which lines you want to Select which lines you want to look at, what scale, colour...look at, what scale, colour..., ,, ,
print it or ...print it or ...
17
Export it to another Export it to another applicationapplication
On Line calibration withOn Line calibration with
ISO 9000 TrackingISO 9000 Tracking
18
EventsEvents are logged are logged automatically.automatically.
CalibrationCalibration Log provides Log provides ISO 9000 TrackingISO 9000 Tracking
NotesNotes for operatorfor operatorcomments.comments.
OperatingOperating Log provides Log provides Usage TrackingUsage Tracking
19
StationStation Log gives easy Log gives easy viewing of station statusviewing of station status
Fast - Simple - Painless !
Setup/ConfigurationSetup/Configuration
With our graphical representation the Remote Station network and PLC’s are easily set-up and maintained.
All the parameters and controlsAll the parameters and controls are shown leaving no gaps or hidden mistakes to be found (or worse NOT found).
20
Full control over all program Full control over all program aspects in one easy to use areaaspects in one easy to use area
“So - everything is visual, can I see something other than graphs and data ?”
The MimicThe MimicMMI Man Machine InterfaceMMI Man Machine Interface
something other than graphs and data ?
YES!YES!You can use all the data collected by MicroScanYou can use all the data collected by MicroScan
and show it in a diagrammatical form (eg. Show how full the tanks are and what
pumps are running).
21
Analogue Level Analogue Level Indicators...Indicators...
On/Off Indicators On/Off Indicators (text, flashing (text, flashing
colours, popups)...colours, popups)...
22
RealReal--time values time values IndicatedIndicated
Meaningful representation with Meaningful representation with easily recognisable symbolseasily recognisable symbols
23
Add buttons to Add buttons to change setpoints, change setpoints,
alarms, swap pages, alarms, swap pages, start/stop motors...start/stop motors...
Up to 50 Mimic pages are Up to 50 Mimic pages are p p gp p gavailable via Hyperlinks...available via Hyperlinks...
24
If you want to avoid bored fingers If you want to avoid bored fingers playing on the nightplaying on the night--shift shift -- all/any all/any pages can be password protected.pages can be password protected.
This is the ‘Fun’ part!This is the ‘Fun’ part!This is the Fun part!This is the Fun part!
Lots of room for the imagination here!Lots of room for the imagination here!
Begin with a blank page...Begin with a blank page...
25
RealReal--time values,time values,
On/Off indicators,On/Off indicators,On/Off indicators,On/Off indicators,
Buttons,Buttons,
Hotspots,Hotspots,
Text,Text,
BarBar--Graphs,Graphs,
...there’s room for ...there’s room for custom PLC recipes.custom PLC recipes.
Add background bitmaps drawn with Add background bitmaps drawn with your favourite graphics editor (Paint your favourite graphics editor (Paint
Shop Pro, CorelDraw, PaintBrush etc).Shop Pro, CorelDraw, PaintBrush etc).
26
Drop a few controls in Drop a few controls in the appropriate placesthe appropriate places
It is now finished and It is now finished and ready to put onlineready to put online
27
Accessory: Tool BoxAccessory: Tool BoxUser Friendly Special Function UtilityUser Friendly Special Function Utility
MicroScan Tool Box MicroScan Tool Box --Function Block SummaryFunction Block Summary
HumidityHumidityDew PointDew PointMoisture ContentMoisture Content
Math Math -- AverageAverageMath Math -- FormulaFormulaMathMath -- Rate ofRate of
Step Control Step Control -- StepStepStep Control Step Control --MasterMaster
Moisture ContentMoisture ContentBatch AverageBatch AverageBatch MinBatch MinBatch MaxBatch Max
Batch Save to DBatch Save to D--BaseBase
Math Math Rate of Rate of ChangeChangeMath Math -- SumSumMath Math -- TrigonometryTrigonometryMath Math -- Tank VolumeTank Volume
Math Math -- TotalTotal
Time Time -- Time ClockTime ClockTime Time -- Multi TimerMulti TimerTime Time -- PC ClockPC ClockTime Time -- PulsePulseTime TimerTime Timer
28
NetworkingNetworking
The sharing of data between the The sharing of data between the ti d i tti d i t
Active Node
active and passive computer active and passive computer nodes running MicroScan is nodes running MicroScan is supported on both:supported on both:
the file server styled network, andthe file server styled network, andthe Windows multiple independent the Windows multiple independent server network.server network.
Security is provided to regulateSecurity is provided to regulate
Net
wor
kPassive Node
Passive Node
Security is provided to regulate Security is provided to regulate the sharing of data.the sharing of data.
Node
More Passive Nodes
Comprehensive Help Comprehensive Help always a click awayalways a click away
29
We supply a comprehensive range of
The Remote StationsThe Remote Stations
pp y p gdata-collection and control devices.
Analogues Input/Output StationsDigital Input/Output Stations
MultiplexersRamp and P ocess Cont olle sRamp and Process Controllers
Remote Station IntroductionRemote Station Introduction
2100-A16
2100-A4
Up to 64 Remote Stations can be connected Up to 64 Remote Stations can be connected --any combinationany combinationRemote Station Power Supply options:Remote Station Power Supply options:
80 ~ 264Vac/dc80 ~ 264Vac/dc23 ~ 90Vdc23 ~ 90Vdc
More Remote Stations
2100-D10 ~ 28Vac/dc10 ~ 28Vac/dc
2100-AO
30
21002100--A16 Remote StationA16 Remote Station
16 Analogue Inputs* Individually ConfigurableThermocoupleThermocouplePt100 or Pt1000mAmVV*16 Bit A/D
2 Analogue Outputs4~10mA0~20mA2~10V0~10V
4 Digital on/off InputsOpto Isolated
30 C
2100-A16
2100-A4
5 to 30 V DCOn/off statesPulses from flow meters etc
2 Relay Outputs* Expandable to 16 by adding the 2100-R Relay Expander* Alarm or Control outputs
On Board Controllers16 on/off controllers8 heat/cool controllers
More Remote Stations
2100-D
2100-AO
21002100--A4(e) Remote StationA4(e) Remote Station
4 Analogue Inputs4 Analogue Inputs* I di id ll C fi bl* I di id ll C fi bl* Individually Configurable* Individually ConfigurableThermocoupleThermocouplePt100Pt100mAmAmVmVVV*12 Bit A/D*12 Bit A/D
2 Analogue Outputs2 Analogue Outputs4~10mA4~10mA0~20mA0~20mA2~10V2~10V0~10V0~10V
2100-A16
2100-A4
4 Digital on/off Inputs4 Digital on/off InputsOpto IsolatedOpto Isolated5 to 30 V DC5 to 30 V DCOn/off statesOn/off statesPulses from flow meters etcPulses from flow meters etc
4 Relay Outputs4 Relay Outputs* Optional 8 outputs 2100* Optional 8 outputs 2100--A4eA4e* Alarm or Control outputs* Alarm or Control outputs
On Board ControllersOn Board Controllers4 on/off controllers (21004 on/off controllers (2100--A4)A4)4 heat/cool controllers (21004 heat/cool controllers (2100--A4e)A4e)
More Remote Stations
2100-D
2100-AO
31
21002100--D Remote StationD Remote Station
12 Digital on/off InputsOpto Isolated5 to 30 V DC
2100-A16
2100-A4
Up to 500HzOn/off statesPulses from flow meters etc
12 Relay Outputs2 Amps 250 V AC
More Remote Stations
2100-D
2100-AO
21002100--AO Remote StationAO Remote Station
8 Analogue InputsmA or V selectable
8 Analogue OutputsmA or V selectable
2 Relay Outputs12 Digital Outputs
2100-A16
2100-A4
More Remote Stations
2100-D
2100-AO
32
Connecting Field Station’s via Connecting Field Station’s via Data HiData Hi--WayWay
RS422/485 Data Hi-WayRS232
2100-SeriesLength of Data HiLength of Data Hi--way before a way before a booster is required:booster is required:
RS422 2 pair = 1.2km typicalRS422 2 pair = 1.2km typical
Option = MODBUS RTU
2100-IS
More Remote Stations
2100-Series
RS422 2 pair 1.2km typicalRS422 2 pair 1.2km typical
RS485 1 pair = 0.5km typicalRS485 1 pair = 0.5km typical
Data HiData Hi--way cable type is low way cable type is low capacitance data cable with overall capacitance data cable with overall screen screen -- cat5 or similarcat5 or similar
Connecting Field Station’s via Connecting Field Station’s via EthernetEthernet
HUB
2100-A16-NET
2100-Series
2100-NET
RS422/485
More Remote Stations
2100-Series
33
Connecting Field Station’s via Connecting Field Station’s via Wireless Radio ModemWireless Radio Modem
Option = USB
RS232
2100-IS
RS422/485
2100-Series
RS422/485
Performance (900MHz ISM Band):Performance (900MHz ISM Band):Indoor Urban = Up to 450m*Indoor Urban = Up to 450m*
More Remote Stations
2100-Series
Outdoor Line of Sight:Outdoor Line of Sight:with Dipole = Up to 3km*with Dipole = Up to 3km*with High Gain Antenna = Up to 6km*with High Gain Antenna = Up to 6km*
*Subject to Terrain Conditions*Subject to Terrain Conditions
Connect to multiple remote Connect to multiple remote sites via Wirelesssites via Wireless
SB
or U
S
34
If you wish to find out more or see a live version of MicroScan in action please contact your nearest Intech Instruments Ltd outlet.
More InformationMore Information
your nearest Intech Instruments Ltd outlet. Thank-you for viewing our demonstration.
Christchurch: Ph: +64 3 343 0646Christchurch: Ph: +64 3 343 0646Fx: +64 3 343 0649
E-mail: [email protected]: www.intech.co.nz