microwave sensor for blade tip clearance and …...microwave sensor works on the principle of...

17
1 Microwave Sensor for Blade Tip Clearance and Structural Health Measurements The use of microwave based sensors for the health monitoring of rotating machinery is being explored at the NASA Glenn Research Center. The microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal. The phase shift of the reflected signal is proportional to the distance between the sensor and the component that is being measured. This type of sensor is beneficial in that it has the ability to operate at extremely high temperatures and is unaffected by contaminants that may be present in the rotating machinery. It is intended to use these probes in the hot sections of turbine engines for closed loop turbine clearance control and structural health measurements. Background on the sensors, an overview of their calibration and preliminary results from using them to make blade tip clearance and health measurements on a large axial vane fan will be presented. https://ntrs.nasa.gov/search.jsp?R=20080047680 2020-03-14T21:50:57+00:00Z

Upload: others

Post on 13-Mar-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Microwave Sensor for Blade Tip Clearance and …...microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal

1

Microwave Sensor for Blade Tip Clearance and Structural Health Measurements

The use of microwave based sensors for the health monitoring of rotating machinery is being explored at the NASA Glenn Research Center. The microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal. The phase shift of the reflected signal is proportional to the distance between the sensor and the component that is being measured. This type of sensor is beneficial in that it has the ability to operate at extremely high temperatures and is unaffected by contaminants that may be present in the rotating machinery. It is intended to use these probes in the hot sections of turbine engines for closed loop turbine clearance control and structural health measurements. Background on the sensors, an overview of their calibration and preliminary results from using them to make blade tip clearance and health measurements on a large axial vane fan will be presented.

https://ntrs.nasa.gov/search.jsp?R=20080047680 2020-03-14T21:50:57+00:00Z

Page 2: Microwave Sensor for Blade Tip Clearance and …...microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal

Standards

Certification

Education & Training

Publishing

Conferences & Exhibits

Microwave Sensor for Blade Tip Clearance and Structural Health MeasurementsMark R. WoikeTimothy J. BencicNASA Glenn Research CenterCleveland, Ohio

Page 3: Microwave Sensor for Blade Tip Clearance and …...microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal

2

Mark R. Woike

• NASA Glenn Research Center, Cleveland, Ohio

• Electronics Engineer – Instrumentation, Data and Control Systems – Wind Tunnel and Propulsion Test Facilities

• Currently in the Optical Instrumentation and Non-Destructive Evaluation (NDE) Branch

Page 4: Microwave Sensor for Blade Tip Clearance and …...microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal

3

Microwave Tip Clearance Sensor –Outline

• Sensor Background

• Sensor Calibration

• Testing on an Axial Vane Fan at the Glenn Research Center’s 10x10 Wind Tunnel Facility

Page 5: Microwave Sensor for Blade Tip Clearance and …...microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal

4

Microwave Tip Clearance Sensor -Background

• Designed to measure blade tip clearances

• Developed by Radatec, Inc. (currently Vibro-Meter, SA) through NASA’s Small Business Innovation Research (SBIR) program

• 5.8GHZ microwave sensor, 0.50”(~13mm) in diameter– Sensor is both a transmitting &

receiving antenna – Reflected signal's phase shift is

proportional to distance between sensor and target

Page 6: Microwave Sensor for Blade Tip Clearance and …...microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal

5

Goals & Benefits of Technology

• Well suited for use in hot sections of turbines– Closed loop turbine clearance control– Variable geometry control schemes– IVHM applications

– Tip timing measurements

• Benefits of technology– Rated for high temperature usage

– ~2000°F (~1100°C)– Tested to ~2200°F ( ~1200°C) in a high pressure burner rig

– Accurate at low clearances– Goal of accuracies on the order 1 mil (.025mm)

– Not effected by environmental conditions & contaminants

• Ultimate goal is to use system in an aero engine– Near term goals are to calibrate the system and evaluate its use on

smaller test rigs

Page 7: Microwave Sensor for Blade Tip Clearance and …...microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal

6

High Pressure Burner Rig Testing

HPBR Microwave Sensor Survivability Test

0200400600800

100012001400

0 10 20 30 40 50 60Run Time (Minutes)

Tem

pera

ture

(°C

)

Microwave probe evaluated for survivability and operation in a combustion environment using jet fuel in GRC High Pressure Burner Rig to 2200°F (1200°C). No clearance information obtained only center frequency and reflected energy because of test setup.

Page 8: Microwave Sensor for Blade Tip Clearance and …...microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal

7

Sensor Calibration

• Calibrated two microwave probes – System makes an average

measurement of the geometry within the spot size that is projected on the blade

– Need to map this average reading to the actual minimum clearance.

• Calibration Set up– Rotary table for blade– Linear positioning table for sensor

• Calibrated against two geometries– Thin compressor blade– Thick box to simulate Axial Vane Fan

blade

Page 9: Microwave Sensor for Blade Tip Clearance and …...microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal

8

Calibration – Thick Blade

y = 2.3519E-04x4 - 6.7915E-03x3 + 6.0168E-02x2 + 4.2359E-01x + 3.2987E+00R2 = 9.9995E-01

0.000

1.000

2.000

3.000

4.000

5.000

6.000

7.000

8.000

9.000

10.000

11.000

12.000

0.000 2.000 4.000 6.000 8.000 10.000 12.000 14.000

Actual Clearance (mm)

Mea

sure

d C

lear

ance

(mm

)

Probe #1 - SN E0611, Clearance Correction, Perpendicular Orientation, Wait Time=300us, 2/05/08

Page 10: Microwave Sensor for Blade Tip Clearance and …...microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal

9

Calibration – Thin Blade

y = -2.2619E-03x3 + 6.8695E-02x2 + 1.5082E-01x + 4.2325E+00R2 = 9.9994E-01

0.0000

1.0000

2.0000

3.0000

4.0000

5.0000

6.0000

7.0000

8.0000

9.0000

10.0000

11.0000

12.0000

13.0000

14.0000

0.0000 2.0000 4.0000 6.0000 8.0000 10.0000 12.0000 14.0000

Actual Clearance (mm)

Mea

sure

d C

lear

ance

(mm

)

Probe #1 - SNE0611, Clearance Correction, Parallel to Thin Blade, 3 Blades Per Average, 1/22/08

Page 11: Microwave Sensor for Blade Tip Clearance and …...microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal

10

Sensor Calibration

• Calibration Verification– With current set up observed calibration

accuracy of +/- 0.12mm (~5 mils)– Very repeatable for large blade– More sensitive for small blade

• Observed installation effects– Electric field orientation to blade

– Thin Blade, parallel orientation– Thick Blade, perpendicular orientation

– Backplane– Needs to be greater than a few

wavelengths– Installation depth

– Wave guide effects if too deep

Page 12: Microwave Sensor for Blade Tip Clearance and …...microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal

11

Axial Vane Fan Test

• Goal was to gain experience with the microwave sensor and assess its use on an actual rotating hardware

• Axial Vane Fan– 72” (~1.8M) Diameter Fan– 16 Blades, 1” (~25mm) thick– Two probes installed 90 deg

apart– Operates at 1200RPM

• Acquired data for several configurations– Probes electric field aligned parallel & perpendicular to blade– Acquired both raw & corrected data– Synchronous & Asynchronous data acquisition modes

Page 13: Microwave Sensor for Blade Tip Clearance and …...microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal

12

Axial Vane Fan Test – Probe Installation

Probe Installation - Fan Exterior

Probe Installation -Fan Interior

Page 14: Microwave Sensor for Blade Tip Clearance and …...microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal

13

Axial Vane Fan Test - Status

• In process of reducing & analyzing data

• Probes gave reasonable readings over fan’s operating range– Probe #1 gave best results– Clearances were at levels expected during operation (slides 12 & 13)– As observed in calibration, perpendicular electric field orientation worked

best for large size blade

• Plan is to further analyze– Repeatability of individual blade measurements – Tip timing– Parallel vs. perpendicular electric field orientation results

Page 15: Microwave Sensor for Blade Tip Clearance and …...microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal

14

Axial Vane Fan Test – Clearance Data

Run #7, Probe #1, Perpendicular Orientation, Corrected, Asynchronous Data Mode

0

1

2

3

4

5

6

7

8

9

10

11:28:00 11:29:00 11:30:00 11:31:00 11:32:00 11:33:00 11:34:00 11:35:00 11:36:00 11:37:00

Time

Mea

sure

d C

lear

ance

(mm

)

Avg ClearanceMin Clearance

Page 16: Microwave Sensor for Blade Tip Clearance and …...microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal

15

Axial Vane Fan Test – Clearance Data

Tip Clearance Measurments - One RevolutionRun #5, Probe #1 Parallel Orientation, Synchronous Data Mode

0

0.5

1

1.5

2

2.5

3

3.5

4

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Blade Number (as labeled in the system)

Cle

aran

ce (m

m)

Page 17: Microwave Sensor for Blade Tip Clearance and …...microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal

16

Conclusion / Future Plans

• Finish analyzing data from fan test at 10x10– Repeatability of individual blade tip clearances – Tip timing– Comparison of calibrations vs. use on fan

• Accomplish a comparison test between capacitive, optical, and microwave clearance probes– Rotor Dynamics Test Rig – Axial Vane Fan

• Upgrade system to operate at 24GHZ– Acquire 0.25” (~6mm) diameter probes

• Test on an actual aero engine