mid-infrared nice-ohms spectrometer for the study of cold molecular ions
DESCRIPTION
Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions. . Michael Porambo , Jessica Pearson, Courtney Talicska , Benjamin J. McCall ISMS June 18, 2014 WG12. Outline. Background and Motivation Spectrometer/Instrumentation Present and Future Work. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/1.jpg)
.Mid-Infrared NICE-OHMS Spectrometer for the Study of
Cold Molecular IonsMichael Porambo, Jessica Pearson, Courtney Talicska, Benjamin J. McCallISMSJune 18, 2014WG12
![Page 2: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/2.jpg)
Outline
• Background and Motivation• Spectrometer/Instrumentation• Present and Future Work
![Page 3: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/3.jpg)
Why molecular ions?Why spectroscopy?
![Page 4: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/4.jpg)
http://www.navy.mil/view_single.asp?id=40674
Janne Karaste, http://commons.wikimedia.org/wiki/File:Midsummer_bonfire_closeup.jpg
Combustion
Efficiency of engines†
†Thomas, Mass Spec. Rev., 2008, 27, 485–530.
![Page 5: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/5.jpg)
Atmospheric Chemistry
Interstellar Reactions
•
http://earthobservatory.nasa.gov/IOTD/view.php?id=7373
Resolved, high precision spectroscopy to study
these fields All molecular models drawn in Avogado (http://avogadro.cc/wiki/Main_Page)
![Page 6: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/6.jpg)
Laboratory Astrochemistry
Complex, congested spectra from interstellar medium
Simpler, standard spectra from lab of hypothesized molecules
Better understanding of the ISM (e.g., detection of more molecules)
ESO/C. Malin, http://www.eso.org/public/images/ann13016a/
![Page 7: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/7.jpg)
Challenges• Low number density• Small fraction of ions compared to
neutrals• High rotational temperature
![Page 8: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/8.jpg)
Overcoming Low Number Density
• Cavity enhancement to increase signal
• Heterodyne/frequency modulation spectroscopy to decrease noise
EOM
![Page 9: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/9.jpg)
Heterodyne/Frequency Modulation
![Page 10: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/10.jpg)
Heterodyne/Frequency Modulation
EOM
113 MHz
Relative Frequency (MHz)
EOM
Relative Frequency (MHz)
113 MHz
FMS Signal
![Page 11: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/11.jpg)
Cavity Enhancement
Heterodyne/Frequency Modulation
Noise Immune Cavity-Enhanced
Optical Heterodyne Molecular
Spectroscopy (NICE-OHMS)†
†Ye et al., JOSA B, 1998, 15, 6–15.
EOM
NICE-OHMS
![Page 12: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/12.jpg)
Sideband SpacingCavity Longitudinal Modes
Laser Spectrum
Spectroscopy sidebands must couple into longitudinal modes
![Page 13: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/13.jpg)
NICE-OHMS/NICE-OHVMS Projects
Plasma discharge
Supersonic expansion
Overcoming high rotational temperature
Other talks:MK06FA01
![Page 14: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/14.jpg)
Continuous Supersonic Expansion Discharge Source
Source running with nitrogen (N2+ discharge)
H3+ temperature: 80–110 K†
High pressure in line (≈2 atm)
100 mTorr chamber pressure
Tiny pinhole (0.5 mm diameter)
Low temperature ions
Spectroscopy of this “zone of
silenceӠCrabtree et al., Rev. Sci. Instrum., 2010, 81, 086103.
![Page 15: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/15.jpg)
Difference Frequency Generation
Ti:Sapph (700–1100 nm)
Nd:YAG (1064 nm)
PPLN
EOM
2.8–4.8 µm
![Page 16: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/16.jpg)
Mid-IR NICE-OHMS Spectrometer
Difference Frequency Generation
setup
To EOM
RF Generator (113 MHz)
One of the first broadly tunable mid-IR NICE-OHMS spectrometers†
†Porambo et al., Opt. Lett., 2012, 37, 4422–4424.
NICE-OHMS Signal
![Page 17: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/17.jpg)
Mid-IR NICE-OHMS Spectrometer
Difference Frequency Generation
setup
To EOM
Lock-In Amplifier
RF Generator (113 MHz)
IGBT Switching
Circuit
Function Generator (1–10 kHz)
![Page 18: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/18.jpg)
Adapted from diagram by Thomas Houlahan, Jr.
-1 kV
Source
15 V Power Supply
1-10 kHz
Opto-Isolator
DC/DC Isolator
IGBT Driver
IGBT
Insulated-Gate Bipolar Transistor (IGBT) Switching Circuit
V+
V1GND1In
V2GND2Out
+Vin
-Vin
+Vout
-Vout
VInGND
Out
V-
![Page 19: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/19.jpg)
![Page 20: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/20.jpg)
13000 m3/hr Roots blower system
![Page 21: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/21.jpg)
Temperature Determination with Methane
Estimated methane rotational temperature of 300±28 K
Lower State Energy (cm-1)
ln (I/S)
![Page 22: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/22.jpg)
Present and Future Work• H3
+ spectroscopy to test temperature of ion
• HN2+ spectroscopy to test efficient cooling
• High precision spectroscopy of ions of astrochemical/fundamental interest
![Page 23: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/23.jpg)
High Precision Spectroscopy
Difference Frequency Generation
setup(2.8–4.8 µm)
Optical Frequency Comb
H2CO+C3H3+
![Page 24: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/24.jpg)
Summary• Molecular ions key in combustion,
atmospheric, interstellar reactions• Challenging to study, but overcome
with NICE-OHMS on supersonic expansion discharge source
• Preliminary temperature determinations promising; ultimate goal is precision spectroscopy of cooled ions
![Page 25: Mid-Infrared NICE-OHMS Spectrometer for the Study of Cold Molecular Ions](https://reader036.vdocument.in/reader036/viewer/2022062520/568161ab550346895dd16759/html5/thumbnails/25.jpg)
Acknowledgments
Springborn Endowment, UIUCNASA Earth and Space Science Fellowship
Thomas Houlahan, Jr.