DESCRIPTION
Problem Solution Constraints –Technical –Practical System Overview SD II Progress PCB’s Testing Enclosures Timeline References Questions/Comments Presentation OverviewTRANSCRIPT
![Page 1: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/1.jpg)
Mid-Semester PresentationSenior Design IIOctober 2, 2012
Humidity-Activated Bathroom Fan
![Page 2: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/2.jpg)
Dontavius MorrissetteComputer EngineerDr. Mike Mazzola
Team Advisor
John AyomElectrical Engineer
Brittany BerrymanElectrical Engineer
Chris FlemingElectrical Engineer
Aaron PlunkettElectrical EngineerComputer Engineer
Team Members
![Page 3: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/3.jpg)
Presentation Overview
![Page 4: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/4.jpg)
Problem and Solution
![Page 5: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/5.jpg)
Issues with high humidity in the bathroom:
•Uncomfortable environment
•Structural damage
•Mold
Problem
![Page 6: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/6.jpg)
Humidity-Activated Bathroom Fan:
• Two device system: wall (control) and ceiling module
• Calibrates and sets initial humidity settings for room
• After humidity exceeds 15% of initial calibration, the fan will turn on
• When room returns to the calibrated level, the fan will turn off
• Pushbutton will allow for user override
Solution
![Page 7: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/7.jpg)
Technical and Practical Constraints
![Page 8: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/8.jpg)
Name DescriptionHumidity Resistance The wireless ceiling module must be
able to withstand up to 100% humidity.Activation Accuracy The HABF is activated when the
humidity reaches ±5% of the user set level.
Wireless Transmission The system must have wireless range of at least 30 feet.
Supply Power The control module must operate from 120VAC/60Hz.
Device Power The ceiling module is battery operated with an estimated battery life of no less than 1 year.
Technical Constraints
![Page 9: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/9.jpg)
Type Name DescriptionManufacturability
Size The HABF control module must fit within a single-gang electrical junction box.
Sustainability Maintenance The HABF system must require almost no user interaction or maintenance.
Practical Constraints
![Page 10: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/10.jpg)
Manufacturability: Size
The HABF control module must not exceed 2-1/4"(W) x 3-3/4"(L) x 3-1/4"(D). This will allow the HABF to:
• Fit in to a typical single gang junction box• Replace existing fan switch
Practical Constraints
[1]
![Page 11: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/11.jpg)
Sustainability: Maintenance
The HABF must require limited user interaction relating to device maintenance.
Practical Constraints
![Page 12: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/12.jpg)
2/23/12
System Overview
![Page 13: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/13.jpg)
System Overview Control Module Ceiling Module
![Page 14: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/14.jpg)
2/23/12
Refinements and Progress
•Extended Battery Life• Configure pins for low power• Minimize a wait-time• Eliminate parts
•Add Low Battery Indicator•Reduced Part Sizes•Completed PCB Design
![Page 15: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/15.jpg)
Control Device
![Page 16: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/16.jpg)
Schematic
![Page 17: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/17.jpg)
Printed Circuit Board
Wall Routed
AC/DC Converter
PIC24
XBEE
TRIAC
67mm
83mm
![Page 18: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/18.jpg)
Ceiling Device
![Page 19: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/19.jpg)
Schematic
![Page 20: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/20.jpg)
Printed Circuit Board
Ceiling Routed
Timer
XBEE
PIC24
Humidity SensorVREF
63mm
70mm
![Page 21: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/21.jpg)
Device Enclosures
![Page 22: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/22.jpg)
Control Module• The PCB for the Control Module is sized to fit
inside a single gang junction box.• The module is a drop in replacement for the
factory fan switch.
Ceiling Module• A small enclosure will be constructed to house
the Ceiling Module PCB and batteries.
[1]
![Page 23: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/23.jpg)
Testing
![Page 24: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/24.jpg)
TestingThe following tests will be performed on both devices following the population of both printed circuit boards:
•Control Module Power Supply Measurements
•Ceiling Module Current Draw Measurements
•Final Product
![Page 25: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/25.jpg)
Tasks Left To Do:1. Finalize Code
2. Order PCB
3. Populate PCB
4. Test PCB
5. Design Ceiling Enclosure
![Page 26: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/26.jpg)
2/23/12
Senior Design II TimelineAugust Septemb
erOctober Novembe
rProjectRefinementPCBDesignPCB PopulatingControl ModuleEnclosureCeiling ModuleEnclosureTesting
![Page 27: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/27.jpg)
[1] In techMall, February 16, 2012. Retrieved from http://biotechnological/Single-Gang-In-Wall-Junction-Box-
S1-18- W-1G-p/30780.htm
[2] Honeywell. “HIH-5030/5031 Series Low Voltage Humidity Sensors”, in Digi-Key. Retrieved from http://www.digikey.com/
References
![Page 28: Mid-Semester Presentation Senior Design II October 2, 2012 Humidity-Activated Bathroom Fan](https://reader036.vdocument.in/reader036/viewer/2022062401/5a4d1b3b7f8b9ab05999e844/html5/thumbnails/28.jpg)
Mid-Semester PresentationSenior Design IIOctober 2, 2012
Humidity-Activated Bathroom Fan