A Midea ducted inverter system puts total climate control right at your fingertips. When you’ve worked hard making your home as attractive and comfortable as possible, it’s the perfect solution in every respect. Multi-room, year-round comfort is delivered through discreetly designed and positioned air vents supplied by your specialist air conditioning retailer. Your retailer will also design all the ductwork in your ceiling to provide the best mix of air distribution and quietness. This ensures your Midea outdoor unit delivers the precise amount of cooling or heating required to maintain your living space just the way you like it.

In-ceiling cassettes are another alternative for homes, shops and offices, using stylish ceiling mounted panels to distribute heating or cooling evenly over larger spaces.

Total comfort at your fingertipsYour wired wall mounted control panel lets you adjust the features of your Midea ducted unit to suit your own needs.

ON/OFF, temperature setting, timer functions and fan speed speed settings are just some of the functions accessible.

You can even lock the panel settings to keep little fingers from making unwanted adjustments.

Year round comfort, all around the house

2

Page 3: Midea Ducted and Cassette Split Systems

3D DC Inverter technology saves energy, cuts costs.▶ The compressor and both indoor and outdoor fan motors are Brushless DC

type to reduce noise and increase energy efficiency.

▶ Power output adjusts automatically to maintain precise temperature control. When reaching the desired SET temperature the compressor speed is adjusted to minimise power usage.

▶ Utilising 180° Sine wave technology in their compressors allows Midea greater efficiency, less vibration and noise, and greater reliability over common 120° sawtooth compressors.

3

Page 4: Midea Ducted and Cassette Split Systems

12.5 - 17 kW5 - 10kW

Ducted Systems

A6 Series (Low Profile design)

G2 Series

4

Simplified WiringInter-connection has been reduced to a nonpolar 2-core shield cable, reducing installation cost and the possibility of wiring error.

Diamond Cabinet Featuring a multi-angled structure and unique reinforcing rib. Rugged, durable and low maintenance.

Gold Fin Condenser This corrosion resistant material on the condenser fins enhances and prolongs the heat exchange capacity of the outdoor unit, extending the working life of your air conditioner.

Optimised Outdoor Fan DesignMidea continues their traditional attention to the design of the outdoor fans. Airflow and performance has been optimised while many units are quieter again than previous models.

Wide Operating Range With a generous operating range of -15° to 50° Celsius, you can be confident your Midea system will be performing when you need it most.

Pre-Charged Units are pre-charged for a generous 20 metre pipe run to reduce installation costs.

Built-In Electronic Diagnostics In the unlikely event of a service issue, built-in electronic diagnostics provide precise error code information so your unit can be repaired in the shortest possible time.

Service Valve Cover Protects the outdoor unit service valves from accidental impact as well as capturing any water condensation on the valves.

Product Warranty*A further measure of comfort is provided by our 5 year warranty. *Remote/Wall control one year warranty.

For Commercial Users The new models retain outside air interlock, remote ON/OFF and alarm state terminal connections on PC Board.

Auto Air Volume Optimisation (Ducted only)Once the unit is set on the “auto airflow adjustment” mode, the fan speed changes from low speed to high speed automatically. By calculating the fan speed and power input, the unit can detect the static pressure required and optimize the airflow accordingly.

Page 5: Midea Ducted and Cassette Split Systems

ModelIndoor CA6MD-50W CA6MD-70W CA6MD-100W CG2HD-125W CG2HD-140W CG2HD-170W

Outdoor CUOU-50D CUOU-70D CUOU-100D CUOU-125D CUOU-140D CUOU-170

Power Supply V-Ph-Hz 220~240-1-50 220~240-1-50 220~240-1-50 220~240-1-50 220~240-1-50 220~240-1-50

Cooling

Rated Capacity KW 5.00 7.00 10.00 12.50 14.00 17.00

Capacity Range KW 2.0~6.0 2.8~8.4 4.0~12.0 5.0~15.0 5.6~16.1 6.8~19.5

Rated Input W 1500 (460~1824) 2120 (640~2550) 3050 (920~3640) 3785 (1150~4550) 4250 (1290~5250) 5155 (1560~5950)

Rated Current A 7.0 (2.0~8.1) 9.7 (2.9~11.5) 13.9 (4.1~16.2) 17.5 (5.1~20.2) 19.5 (5.8~21.7) 23.7 (7.0~26.5)

EER W / W 3.33 3.30 3.28 3.30 3.29 3.30

AEER W / W 3.26 3.25 3.24 3.27 3.27 3.28

Heating

Rated Capacity KW 5.60 7.50 10.50 12.50 14.50 17.50

Capacity Range KW 2.2~6.7 3.0~9.0 4.2~12.5 5.0~15.0 5.8~17.5 7.0~21.0

Rated Input W 1670 (670~2000) 2270 (900~2700) 3180 (1250~3800) 3785 (1500~4500) 4300 (1700~5200) 5200 (2050~6250)

Rated Current A 7.8 (3.1~9.4) 10.5 (4.5~12.8) 14.7 (5.8~17.6) 17.5 (7.0~21.0) 19.5 (7.8~23.5) 23.7 (9.5~28.5)

COP W / W 3.35 3.30 3.30 3.30 3.37 3.37

ACOP W / W 3.29 3.26 3.27 3.27 3.35 3.34

Star RatingCooling 2.0 2.0 1.5 2.0 2.0 2.0

Heating 2.0 2.0 2.0 2.0 2.0 2.0

Max. input consumption W 2100 3000 3900 5500 5500 6000

Max. input current A 11.0 16.0 21.0 26.0 26.0 30.0

Moisture Removal L/hr 1.4 1.5 1.7 3.0 4.0 4.0

Compressor Type Twin Rotary Twin Rotary Twin Rotary Twin Rotary Twin Rotary Twin Rotary

Indoor air flow (Hi/Mid/Lo) L/sec 250/212/175 390/320/270 555/460/360 900/765/640 915/790/650 1055/890/820

Indoor external static pressure (Max) Pa 100 160 160 200 200 200

Indoor noise level (Hi/Mid/Lo) dB(A) 43/40/38 45/41/38 49/46/42 49/46/42 49/45/42 49/46/42

Outdoor air flow (Hi) L/sec 695 970 1530 1945 2000 2085

Outdoor noise Sound Pressure (Hi) dB(A) 58 58 61 62 62 62

Outdoor noise Sound Power (Hi) dB(A) 69 69 70 71 71 71

Indoor unitDimension (W×D×H) mm 880x600x210 1100x720x248 1360x720x248 1200x625x380 1200x625x380 1400x858x440

Net/Gross weight kg 23.5/29 31/38 40/48 54/60 54/60 75/83

Plenum SizeSupply Air mm 706x136 926x175 1186x175 1000x253 1000x253 1188x385

Return Air mm 782x190 1001x228 1261x228 1145x334 1145x334 1188x385

Outdoor unit Dimension (W×D×H) mm 845x363x702 946x410x810 946x410x810 952x415x1333 952x415x1333 952x415x1333

Net/Gross weight kg 42/45 61/66.5 68.5/74 100/114 116/130 116/130

Refrigerant type/ Quantity R410A/1925g R410A/3050g R410A/3950g R410A/4650g R410A/5050g R410A/5050g

Pre-charged to m 20 20 20 20 20 20

Extra charge amount g/m 15 30 30 30 30 30

Refrigerant piping

Liquid side/Gas sidemm

(inch)6.35/12.7

(1/4"/1/2")9.52/15.9

(3/8"/5/8")9.52/15.9

(3/8"/5/8")9.52/19

(3/8"/3/4")9.52/19

(3/8"/3/4")9.52/19

(3/8"/3/4")

Max. pipe length m 30 50 50 65 65 65

Max. difference in level m 20 25 25 30 30 30

Connecting wiring

Power wiring 3 plus EARTH 3 plus EARTH 3 plus EARTH 3 plus EARTH 3 plus EARTH 3 plus EARTH

Signal wiring2-core shielded

wire2-core shielded

wire2-core shielded

wire2-core shielded

wire2-core shielded

wire2-core shielded

wire

Operation temperature Cooling/Heating ºC 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30

Ambient temp Cooling/Heating ºC -15~50/-15~24 -15~50/-15~24 -15~50/-15~24 -15~50/-15~24 -15~50/-15~24 -15~50/-15~24

Single Phase Ducted Specifications

Specifications based on Testing conditions as specified in AS/NZ3823 1.1.1998. Cooling: Indoor DB 27°C WB 19°C, Outdoor DB 35°C WB 24°C. Heating: Indoor DB 20°C, Outdoor DB 7°C. Star Rating, Comparative Energy Consumption (CEC) and Minimum Energy Performance Standards (MEPS) conform to AS/NZS 3823.2.2:2013. Running current is at rated conditions and does not include compressor start-up or variations in power supply or load requirements. Noise levels are measured in a semi - anechoic chamber. Output capacities are reduced once ambient temperatures are >35°C or <7°C Design & Specifications are subject to change for product improvement. E&O E

5

Page 6: Midea Ducted and Cassette Split Systems

Cassettes are ideal for large open spaces in both domestic and commercial applications or where roof space is limited.

Cassette Type Split Systems

For easier installation and maintenance, the body height has been reduced from previous models.

The drain pump can lift condensing water up to 750mm.

Indoor air quality can be further enhanced by adding fresh air intakes.

Compact Machine Body Built-in Water Pump A Breath of Fresh Air

6

Page 7: Midea Ducted and Cassette Split Systems

Single Phase Cassette Specifications

Specifications based on Testing conditions as specified in AS/NZ3823 1.1.1998. Cooling: Indoor DB 27°C WB 19°C, Outdoor DB 35°C WB 24°C. Heating: Indoor DB 20°C, Outdoor DB 7°C. Star Rating, Comparative Energy Consumption (CEC) and Minimum Energy Performance Standards (MEPS) conform to AS/NZS 3823.1.2:2012. Running current is at rated conditions and does not include compressor start-up or variations in power supply or load requirements. Noise levels are measured in a semi - anechoic chamber. Output capacities are reduced once ambient temperatures are >35°C or <7°C. Design & Specifications are subject to change for product improvement and E&O excepted.

Reserved spaces for air side-outlet to connect ductwork to another nearby room.

Wired controllers are available for use in both commercial and domestic situations. Wireless controllers are optional.

The new D2 series cassettes have outside air interlock, remote ON/OFF and alarm state terminal connections on PC Board.

Room for Expansion Controllers For Commercial Users

7

ModelIndoor CD2C-50W CD2C-70W CD2C-100W CD2C-125W CD2C-140W

Outdoor CUOU-50C CUOU-70C CUOU-100C CUOU-125C CUOU-140C

Power Supply V-Ph-Hz 220~240-1-50 220~240-1-50 220~240-1-50 220~240-1-50 220~240-1-50

Cooling

Rated Capacity W 5300 (2100-6360) 7000 (2800-8400) 10500 (4200-12600) 12500 (5000-15000) 14000 (5600-16800)

Rated Input W 1475 (590-1800) 2000 (800-2400) 3180 (1270-3820) 3790 (1520-4550) 4250 (1700-5100)

Rated Current A 7.0 (2.8-8.4) 9.8 (3.9-11.8) 14.5 (5.8-17.5) 17.5 (7.0-21.0) 20.0 (8.0-24.0)

EER W / W 3.59 3.50 3.30 3.30 3.30

AEER W / W 3.51 3.44 3.27 3.27 3.27

Heating

Rated Capacity W 5800 (2320-6960) 7500 (3000-9000) 10800 (4320-12950) 13000 (5200-15600) 14500 (5800-17500)

Rated Input W 1615 (640-1780) 2190 (880-2410) 3200 (1280-3550) 3850 (1550-4250) 4300 (1720-4750)

Rated Current A 7.5 (3.0-9.0) 10.0 (4.0-12.0) 14.8 (5.8-17.8) 17.5 (7.0-21.0) 20.0 (8.0-24.0)

COP W / W 3.59 3.42 3.38 3.38 3.37

ACOP W / W 3.52 3.37 3.34 3.35 3.35

Star RatingCooling 2.5 2.0 2.0 2.0 2.0

Heating 2.5 2.0 2.0 2.0 2.0

Max. input consumption W 2100 3000 3900 5500 5500

Max. input current A 11 16 21 26 26

Moisture Removal L/hr 1.4 1.5 1.7 3.0 4.0

Compressor Type Twin Rotary Twin Rotary Twin Rotary Twin Rotary Twin Rotary

Indoor air flow (Hi/Mid/Lo) L/sec 345/290/250 440/335/275 640/555/500 640/555/500 640/555/500

Indoor noise level (Hi/Mid/Lo) dB(A) 49/44/39 49/45/41 52/49/45 53/49/45 54/51/48

Outdoor noise level (Hi) dB(A) 58 58 61 62 62

Outdoor Sound Power level dB(A) 69 69 70 71 71

Indoor unit

Dimension (W×D×H) mm 840x840x205 840x840x245 840x840x287 840x840x287 840x840x287

Packing (W×D×H) mm 900x900x225 900x900x265 900x900x292 900x900x292 900x900x292

Net/Gross weight kg 21.3/25 24/28 28.7/32.8 28.7/32.8 28.7/32.8

Panel

Dimension (W×D×H) mm 950x950x55 950x950x55 950x950x55 950x950x55 950x950x55

Packing (W×D×H) mm 1035x1035x90 1035x1035x90 1035x1035x90 1035x1035x90 1035x1035x90

Net/Gross weight kg 5/8 5/8 5/8 5/8 6.5/8

Outdoor unit

Dimension (W×D×H) mm 845x363x702 946x410x810 946x410x810 952x415x1333 952x415x1333

Packing (W×D×H) mm 965x395x755 1090x500x865 1090x500x865 1095x495x1480 1095x495x1480

Net/Gross weight kg 42/45 61/66.5 68.5/74 100/114 116/130

Refrigerant

Type R410A R410A R410A R410A R410A

Pre-charged tog 1925 3050 3950 4650 5050

m 20 20 20 20 20

Extra charge g/m 15 30 30 30 30

Refrigerant piping

Liquid side/Gas side mm 6.35/12.7(1/4"/1/2") 9.52/15.9(3/8"/5/8") 9.52/15.9(3/8"/5/8") 9.52/19(3/8"/3/4") 9.52/19(3/8"/3/4")

Max. pipe length m 30 50 50 65 65

Max. difference in level m 20 25 25 30 30

Connecting wiringPower wiring 3 plus EARTH 3 plus EARTH 3 plus EARTH 3 plus EARTH 3 plus EARTH

Signal wiring 2-core shielded wire 2-core shielded wire 2-core shielded wire 2-core shielded wire 2-core shielded wire

Operation temperature ºC 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30

Ambient temp Cooling/Heating ºC -15~50/-15~24 -15~50/-15~24 -15~50/-15~24 -15~50/-15~24 -15~50/-15~24

Page 8: Midea Ducted and Cassette Split Systems

Midea has its headquarters in Guangdong Province, China, which covers over one million square metres (pictured above). The company maintains over 85 testing centres, employs

over 1,000 engineers and manufactures over 1,000 different products.

Today, Midea supplies 30% of the world’s air conditioning, for you to enjoy at home.

mideaappliances.com.au

CE

0031

D 0

8/16

Available from

48A Radford Road, Reservoir, Vic. 3073. Tel: (03) 9495 2899

Distributed by