mike nankivell - marketing director space airconditioning stand c111 1 is energy efficiency up to...

39
Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 QuickT TIFF (U are nee Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive Article 9 Mike Nankivell Marketing & Business Development Director Space Airconditioning plc

Upload: heriberto-gates

Post on 28-Mar-2015

212 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

1

QuickTime™ and aTIFF (Uncompressed) decompressorare needed to see this picture.

Is Energy Efficiency Up to

the Measure?

Energy Performance In Buildings DirectiveArticle 9

Mike NankivellMarketing & Business Development Director

Space Airconditioning plc

Page 2: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Space Air HQ, Guildford

30 Years

1980 - 2010

Intelligent

Distribution

Largest

Independent

Distributor

GuildfordBirmingham

BristolLeeds

Manchester

SPACE AIRCONDITIONING plc UK DAIKIN DISTRIBUTOR

Page 3: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Introduction

• The 160 million buildings in the EU use over 40% of Europe’s energy and create over 40% of its carbon dioxide emissions and that proportion is growing.

• The UK has been given challenges to move towards cleaner and more efficient forms of energy generation and distribution.

• These gases are known as global warming gases.

• Burning these fuels generates carbon dioxide, sulphur dioxide and nitrogen oxide gas emissions.

• Electricity generation has traditionally been based on burning fossil fuels.

Page 4: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

4

QuickTime™ and aTIFF (Uncompressed) decompressorare needed to see this picture.

Content:• Overview of the EPBD• Article 9 - Air Conditioning Inspections• CIBSE Video Clip• Examples of what inspections might reveal• Summary

Page 5: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

5

QuickTime™ and aTIFF (Uncompressed) decompressorare needed to see this picture.

Energy Performance of Buildings Directive

EPBD

Page 6: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

EPBD - Key Objectives• The 2002 European Performance of Buildings Directive (EPBD) implicated most new and existing residential and non-residential buildings, and first began to be implemented in 2006 through Part L of the Building Regulations.

The Key objectives are to promote: - • Improved energy performance of buildings within the EU.• The union of building energy standards across Member States.

Page 7: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

EPBD - Main Provisions

• A framework method for calculating the energy performance of buildings (SBEM).

• Regular inspection of air conditioning required plus the provision of guidelines on best practice in air conditioning use and

replacement.

Certificate to be positioned in a prominent situation in all public buildings over 1000m2.

Certificate to be accompanied by suggestions for cost effective improvements to energy performance.

• Display Energy Certificates required for Public Buildings

• Energy Performance Certificates required for buildings built, sold or rented.

• The viability of alternative energy systems to be considered for new buildings over 1000m2.

• Minimum energy performance standards to be set by Member states.

Page 8: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Air Conditioning Inspections

• Article 9 of the Energy Performance in Buildings Directive requires inspections of air conditioning systems over 12kW rated output every 5 years.

• The Energy Performance of Buildings (Certificates and Inspections) Regulations 2007 - SI 991:2007 implemented Articles 7 – 9 of the Directive (In England and Wales)

Page 9: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

The Regulations

Inspections of air-conditioning systems

Systems must be inspected by the relevant date and then every 5 years:

Systems installed after 1/1/2008 must be inspected within 5 years of installation

Existing systems over 250kW must be inspected by 4/1/2009

Existing systems over 12kW by 4/1/2011

Page 10: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Penalties

• Building owners failing to meet inspection deadlines face fines:

£300 to £5,000 depending on building size/number of infringements

(Possible ‘name and shame’ approach)

Enforcement by Trading Standards officers

(With powers to repeat fines on each recorded infringement)

• Potential reduced property values where inspection reports indicate significant improvement recommendations (or no report is available)

• Potential for building insurance claims to be void?

Page 11: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

The Regulations

The inspection report must include:

• An assessment of the air-conditioning efficiency and the sizing of the system compared to the cooling requirements of the building

• Contain appropriate advice on possible improvements to the system, replacement of the system and alternative solutions.

Page 12: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

The Regulations

The inspection report must include the following information:

(a) the address of the building in which the system is located.

(b) the name of the energy assessor.

(c) the name and address of the energy assessor's employer, or

if he is self-employed, the name under which he trades and his address.

(d) the date on which the inspection occurred.

(e) the name of the Approved Accreditation Scheme of which the energy assessor is a member.

Page 13: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Background

• A joint working group led by CIBSE with ACRIB/IOR, BSRIA, FETA, HVCA and with support from DCLG developed guidance on Article 9 implementation

(Inspection of air conditioning systems)

• CIBSE TM 44 published in 2007 gives detailed guidance on assessment methodology and reporting

Page 14: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Air conditioning systems with over 12kW rated cooling output could comprise:

• Individual split systems • Multi-split systems • Centralised systems • Distributed heat pump systems • The rated cooling output of a system may exceed 12kW

where a number of individual units of less than 12kW rated output have common control -(electronic or user)

System Types

Page 15: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Overall Approach

• Simplicity of inspection, minimising costs and disturbance to operation

• Providing useful advice to owner / operator

• Simplest level to identify poor performers

• Minimise burden where systems are well maintained

• Non-invasive ‘observation’ basis

• Minimise risks and potential liabilities to inspector

Page 16: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Methodology

Two track approach1. simple systems – simple inspections2. complex systems – a more detailed

inspection

Broadly, systems with air distribution ductwork (rather than flexible pipes) will require the more detailed inspection

Page 17: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Process

Three key stages in the inspection:

1) Off-site paperwork and energy data (if available)

2) On site examination

3) Report and proposals for possible improvements

Page 18: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

QuickTime™ and aTIFF (Uncompressed) decompressorare needed to see this picture.Basic Procedure

• Review existing documentation

• Compare maintenance with industry good practice

• Inspect system components

• Assess controls and settings

• Estimate cooling load

• Review potential for improvement or alternatives

• Report findings and advice

Page 19: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

19

Further Information

• The CIBSE guide TM44 contains all of the information required for the inspections and includes:– Summary of system types– Checklists– Suggested reporting format

• Available from

www.cibse.org/publications

Page 20: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

DCLG Information

QuickTime™ and a

TIFF (LZW) decompressor

are needed to see this picture.

QuickTime™ and a

TIFF (LZW) decompressor

are needed to see this picture.

Available from DCLG website

http://www.communities.gov.uk/publications/planningandbuilding/airconditioning

http://www.communities.gov.uk/archived/publications/planningandbuilding/airconbusinessesguide

Page 21: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Maximising Efficiency Opportunities

Air Conditioning Inspections will identify:

• System design flaws

• Equipment/installation standard issues

• Maintenance failings

• End-user/operator error

Page 22: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

QuickTime™ and aTIFF (Uncompressed) decompressorare needed to see this picture.

22

To see an informative short film “Putting Airconditioning to the Test”

go to:

http://www.workplacelaw.net/videos/conference_films/AirConditioning.html

Page 23: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

23

QuickTime™ and aTIFF (Uncompressed) decompressorare needed to see this picture.

So….Is Energy Efficiency

Up to the Measure?

Energy Performance In Buildings DirectiveArticle 9

Page 24: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

• An absence of appropriate records

• A simple means of reducing carbon

• A need to plan for remedial action

• Great potential to reduce operating costs

• Answers to operating efficiency problems

• Let’s look at some examples……..

What Air ConditioningInspections could reveal

Page 25: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Design

Page 26: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Design

Page 27: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Installation

Page 28: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Maintenance

Page 29: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Installation

Page 30: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Maintenance

Page 31: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

End User/Operator

Page 32: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

End User/Operator

Page 33: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

End User/Operator

Page 34: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

End User/Operator

Page 35: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Synergies and Benefits

Over one third of all air conditioning in buildings in Europe is more than 15 years old.

• Synergy between EPBD air conditioning inspections and ODS Regulation. - ref. HCFC Phase-out.

• Energy inspections will highlight opportunities to replace older systems covered by other legislation.

• Will increase awareness of efficiency advantages of new development in air conditioning technology.

• F Gas Regulation also involves mandatory, recorded leak check inspections.• EPBD now intrinsic to Part L Building Regs.

Page 36: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

QuickTime™ and aTIFF (Uncompressed) decompressorare needed to see this picture.

36

Page 37: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

• “Non Compliance Costs” campaign is a widely supported CIBSE initiative

• Highlight growing concern in the industry re: lack of compliance/enforcement

• Objective: to drive government to deliver a more successful approach

• Help bldg owner/operators

• Identify an enforcement body that can act

Page 38: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

Summary

• Air conditioning inspections represent an opportunity to improve the efficiency of our buildings

• Air conditioning inspections are required - by law

• Non compliance will cost us all in the long run

• Make sure the energy efficiency of our building’s air conditioning systems are:

UP TO THE MEASURE

Page 39: Mike Nankivell - Marketing Director Space Airconditioning stand C111 1 Is Energy Efficiency Up to the Measure? Energy Performance In Buildings Directive

Mike Nankivell - Marketing Director Space Airconditioning stand C111

39

Is Energy Efficiency Up to

the Measure?

Thank you for your attention