Page 1: Mini-implant ball The essential complement · implant axis Screwing in the implant Reduced size to take up less space on the sterile field and in the autoclave. Readability of the

Mini-implant ballThe essential complement

Page 2: Mini-implant ball The essential complement · implant axis Screwing in the implant Reduced size to take up less space on the sterile field and in the autoclave. Readability of the

- Obi Ø 2.7

Ø 3.5

Ø 2.7

Ø 2.35

Ø 2.25

4

2.8

INDICATIONS

RELIABILITY

Tissue level positioningDesigned to be positioned in single-stage surgery, the OBI implant has characteristics that give it high primary stability allowing for immediate loading.

Smooth tissue level neck• Limits gingival manipulations• Circular machining grooves on the neck for optimum hemidesmosomal grip

Asymmetrical thread • Homogeneous distribution of masticatory forces• Excellent primary stability right from the placement of the implant

Double thread• Reduced bone heat-up and insertion time

Atraumatic apex • Atraumatic progression due to its rounded end

Proven STAE® surface treatment• Micro sandblasting with titanium oxide and etching with nitric and hydrofluoric acids • 23 years of clinical experience

Stabilization of removable prostheses • Economical and fast solution• Thin ridges• Immediate loading and stabilization of full removable dentures

The OBI mini-implant balls have the same technical characteristics and the same quality requirements as our traditional implants.

Page 3: Mini-implant ball The essential complement · implant axis Screwing in the implant Reduced size to take up less space on the sterile field and in the autoclave. Readability of the

- Obi Ø 2.7

1 2 3 4

SPEED AND SIMPLICITYA quick surgical protocol = only one drill is required

One simple and compact kit

NEWVERSION

Drilling with the Ø 2 drill Incision usingthe gingival cutter

Verification of theimplant axis

Screwing in the implant

Reduced sizeto take up less space on the sterile field and in the autoclave.

Readability of the sequencesdue to the presentation of instruments in order of use.

1. Geriatric narrow implants for wearers of full dentures: cli-nical aspects and prospects with OBI mini-implants Dr Cédric Huard, Dr Marion Bessadet, Dr Emmanuel Nico-las and Dr Jean-Luc Veyrune - University of Auvergne (Cler-mont-Ferrand, France)Clinical, Cosmetic and Investigational Dentistry 2013:5 63–68 2. Contribution of mini-implants to the treatment of total mandibular edentulism Dr Cédric Huard, Dr Marion Bessadet, Dr Marie-Laure JALA-BERT-MALBOS, Dr Christophe DESCHAUMES, Dr Julien DU-ROUX, Dr Didier COMPAGNON, Dr Emmanuel Nicolas, Dr Pas-cal AUROY, Dr Maurice MORENAS and Dr Jean-Luc Veyrune - University of Auvergne (Clermont-Ferrand, France)Actualités Odonto-Stomatologiques - n° 256 - December 2011

3. Stabilization of a removable prosthesis using Ø 2.7 mm OBI implants Dr Gérard BADER, Mr Yves GASTARD and Dr Xavier RAVALECRevue Implantologie - November 2010 4. SR Phonares and OBI mini-implants: an alliance of choice – Prosthetic strategy Mr Y. Gastard (dental technician), Dr F. Truchot, Dr X. Ravalex and Dr G. BaderStratégie prothétique – January-February 2011

Clinical studies and bibliographic references:

Page 4: Mini-implant ball The essential complement · implant axis Screwing in the implant Reduced size to take up less space on the sterile field and in the autoclave. Readability of the

euroteknika: 726 rue du Général De Gaulle - 74700 Sallanches - FranceT : +33 (0)4 50 91 49 20 - F : +33 (0)4 50 91 98 66 - [email protected] - www.etk.dental

euroteknika implants are medical devices of Class IIb (European Directive 93/42/CEE) comply with the standards of conformity and CE0459 marking carrier. Read carefully the instructions for use and user manual.