minimum and general data sets

Upload: ruben-morillo

Post on 14-Apr-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/30/2019 Minimum and General Data Sets

    1/4

    PCP-R IFTS Min&GenDataSets.DRAFT.20050901.Posted.xls General & Minimum Data Sets (8/4/2011) C-FER Technologies

    PCP-RIFTS: General Data Set

    PCP-RIFTS: Min imum Data Set (1)

    Parameter DescriptionCompany Name Name of operating company (Participant)

    Division Name Name of operating unit, group of field, etc.

    Field Name Name of oil field

    Field Location (Country) Name of country field is in

    Location of PCP Supply Centre Country, Provinces/State, and nearest Town/City of source of PCP system. If more than one supply centre, pleaprovide location of main supply centre.

    Location of PCP Teardown Facility Country, Province/State, and nearest Town/City where pulled PCPs are sent for teardown and inspection. If mothan one teardown facility, please provide location of main teardown facility.

    Field Type (Onshore/Offshore)Onshore, Offshore (Platform), Offshore (Subsea), Onshore/Offshore

    Oil Density at STP Oil density inAPI at standard temperature (15C) and pressure (1 atm)

    Reservoir Temperature Fluid temperature at the reservoir conditions

    Dead Oil Viscosity at STP Dead oil viscosity at standard temperature (15C) and pressure (1 atm)

    Oil Bubble Point Pressure Bubble point (vapour) pressure of oil at Reservoir Temperature

    Well Name Name or identifier of well

    Well Type (Geometry) Vertical, Slant, Deviated, Horizontal, S idetracked, Re-Entry Sidetrack, or Multilateral

    Wellhead location Onshore, Platform, Subsea

    Pad or Platform Name Name of group of wells

    Reservoir Name/Zone Name(s) of producing reservoirs (during production period)

    Reservoir Type Carbonate, Consolidated Sandstone, Unconsolidated Sandstone, Evaporite

    Reservoir Recovery Mechanism Aquifer drive, Solution Gas Drive, Water flood, EOR (e.g., CO2 flooding, Water-Alternating-Gas (WAG), PolymeFlood, Steam stimulation, etc)

    Completion Type Perforated Casing, Open hole, or Unknown

    Sand Control Type Type of sand control installed in the well during the production period, e.g. Gravel Pack, Slotted Liner, Wire-wrapped Screen, etc. If no sand control installed, please indicate None.

    Production Casing Outer Diameter Nominal outer diameter of the production casing

    Production Period Number Production period number for well

    Date Installed (mm/dd/yyyy) Date PCP system was installed

    Date Period Started (mm/dd/yyyy) Date PCP system was first started. If not provided, the Date Period Started will be assumed equal to the DateInstalled.

    Period Status Status of the production period: Period Completed or Still on Production.

    Date Period Ended (mm/dd/yyyy) Date PCP system failed, was shutdown, or last date record was updated if PCP still running. If not provided, theDate Period Ended will be assumed equal to the Date Pulled.

    Date Pulled (mm/dd/yyyy) Date PCP system was pulled

    Actual Runtime Days the PCP system was actually running. If not provided, Actual Runtime will be assumed equal to Duration

    PCP System Failed? Did/has the PCP system failed (Yes or No)? This parameter should be consistent with the Period Status. If PerioFailure Information

    Field Information

    Fluid Information

    Well Information

    Runtime Data

    (dates)

    Status ="Still Running", then PCP System Failed? should be "No". If PCP System Failed? ="Yes", then Period

    Status should be "Period Completed".

    Reason for Pull: General General category of why the PCP was pulled

    Reason for Pull: Specific More specific reason why the PCP was pulled

    Primary Failed System Only required if both PCP and Tubing System failed. If only one system fails, then the Primary Failed System isdefaulted to that system.

    PCP System - Primary Failed Item The primary failed PCP component or partPCP System - Primary Failure Descriptor The primary descriptor of the PCP System - Primary Failed Item

    PCP System - Secondary Failure Descriptor The secondary descriptor of the PCP System - Primary Failed Item

    PCP System - Failure Cause: General Circumstances during design, manufacture or use that led to the PCP System failure

    PCP System - Failure Cause: Specific Specific circumstances during design, manufacture or use that led to the PCP System failure

    PCP System - Contributing Cause: General Circumstances during design, manufacture or use that contributed to the PCP System failure

    PCP System - Contributing Cause: Specific Specific circumstances during design, manufacture or use that contributed to the PCP System failure

    Tubing System Failed? Did/has the Tubing System failed?

    Tubing System - Primary Failed Item The primary failed Tubing component or part

    Tubing System - Primary Failure Descriptor The primary descriptor of the Tubing System - Primary Failed Item

    Tubing System - Secondary Failure Descriptor The secondary descriptor of the Tubing System - Primary Failed Item

    Tubing System - Failure Cause: General Circumstances during design, manufacture or use that led to the Tubing System failure

    Tubing System - Failure Cause: Specific Specific circumstances during design, manufacture or use that led to the Tubing System failure

    Tubing System - Contributing Cause: General Circumstances during design, manufacture or use that contributed to the Tubing System failure

    Tubing System - Contributing Cause: Specific Specific circumstances during design, manufacture or use that contributed to the Tubing System failure

    Failure Comments Specific notes regarding the failure. Include a description of the "contaminant" (e.g., sand, scale, asphaltene, etcthe Contaminated failure descriptor is used.

    Control Panel Type Type of control panel: Switchboard, Switchboard with Soft Start, Variable Frequency Drive

    Control Panel Vendor Vendor of control panel

    Power Transmission Type Type of power transmission: Belts and Sheaves, Gears, Combination, or Other

    Prime Mover Type Type of prime mover: Electric Motor, Internal Combustion Engine, or Hydraulic Motor.

    Drivehead Vendor Name of vendor/manufacturer of surface drivehead

    Prime Mover Rated Power Rated power of prime mover on surface drive

    Power Source Local Power Line/Grid, Field Generator, Wellsite Generator

    Power Quality Excellent, Good, Average, Low, Poor

    (as per PCP

    Failure

    Nomenclature

    Standard)

    Surface

    Equipment Data

    IF Rod Driven PCP

    System

    Confidential 1 / 4

  • 7/30/2019 Minimum and General Data Sets

    2/4

    PCP-R IFTS Min&GenDataSets.DRAFT.20050901.Posted.xls General & Minimum Data Sets (8/4/2011) C-FER Technologies

    PCP-RIFTS: General Data Set

    PCP-RIFTS: Min imum Data Set (1)

    Parameter Description

    PCP Vendor Name of vendor/manufacturer of pump components (e.g., Weatherford BMW). If rotor vendor and stator vendordifferent, use the stator vendor as the Pump Vendor.

    Pump Model (SI) Catalogue model designation of pump (e.g., 15-1400)

    Elastomer Model Model designation of stator elastomer

    Elastomer Type Type of stator elastomer (e.g., medium nitrile, high nitrile, fluroelastomer, etc.)

    Rotor Coating Type Type of rotor coating (e.g. chrome, boron, etc.)

    Pump Rated Displacement Rated displacement of the pump

    Pump Rated Differential Pressure Rated differential pressure of the pump

    Stator Serial Number Serial number or unique identifiers for that specific PCP statorRotor Serial Number Serial number or unique identifiers for that specific PC P rotor

    In-Test: Date Date pump was bench tested prior to installation

    In-Test: Speed Rotational speed pump was bench tested at (RPM) prior to installation

    In-Test: Reference Differential Pressure Reference pressure of bench test volumetric efficiency (usually rated pressure) prior to installation

    In-Test: Volumetric Efficiency at Reference DP Volumetric efficiency of pump at reference pressure and test speed prior to installation

    In-Test: Friction Torque Friction torque of pump at test speed prior to installation

    In-Test: Volumetric Efficiency at Zero DP Volumetric efficiency of pump at zero differential pressure prior to installation

    Out-Test: Date Date pump was bench tested after pull

    Out-Test: Speed Rotational speed pump was bench tested at (RPM) after pull

    Out-Test: Reference Differential Pressure Reference pressure of bench test volumetric efficiency (usually rated pressure) after pull

    Out-Test: Volumetric Efficiency at Reference

    DP

    Volumetric efficiency of pump at reference pressure and test speed after pull

    Out-Test: Friction Torque Friction torque of pump at test speed after pull

    Out-Test: Volumetric Efficiency at Zero DP Volumetric efficiency of pump at zero differential pressure after pull

    Date Pump Inspected Date pump was inspectedStator New/Used/Repaired When installed, was the stator New or Used (without service or minor servicing only)

    Rotor New/Used/Rechromed When installed, was the rotor New, Used (without service or minor servicing only), Repaired (used and servicedRechromed

    Stator Pull Condition Condition of stator when pulled: Reusable or Not Reusable

    Rotor Pull Condition Condition of rotor when pulled: Reusable or Not Reusable

    Pump Intake Vendor Name of vendor/manufacturer of pump intake

    Pump Intake TypeType of pump intake: None (PCP Opening), Tail Pipe, Standard Bolt-on Intake (Flexshaft), Static Gas Separator

    Bottom-Feeder Gas Separator, Multiple Stator Intakes, Rotary Gas Separator, or Gas Handler

    Pump Intake Pull Condition Condition of pump intake when pulled: Reusable or Not Reusable

    Tag Bar Type Type of pump tag bar (e.g., integral bar or plate or separate downhole component)

    Downhole

    Equipment Data

    Tag Bar Pull Condition Condition of tag bar when pulled: Reusable or Not Reusable

    Pump Seating Depth MD Measured depth of the pump intake

    Pump Seating Depth TVD Vertical depth of the pump intake

    Inclination at PSD Inclination (hole angle) at the Pump Seating Depth

    Maximum Dogleg Maximum curvature that the PCP had to pass through during installation

    Tubing Outer Diameter Nominal outer diameter of production tubing

    Tubing Weight Weight of the production tubing

    Tubing Internal Coating Type Coating type on ID of production tubing string, if tubing ID is coated

    Rod Diameter Nominal diameter of rod string

    Rod Material Grade Material grade of rod string

    Rod Type Type of rod string: Standard, Continuous, or Hollow

    Rod Centralizer Type Type of rod string coupling centralizers, if used (Coated, Spin Thru)

    Rod Guide Type Type of rod string rod body guides, if used

    Tubing Anchor Installed? Was a device installed to anchor the tubing to the casing?

    Tubing Anchor Model Model designation of torque anchor. Alternatively, torque anchor vendor may be provided.

    Tubing Rotator Installed? Was a device installed to rotate the tubing?

    Tubing Rotator Vendor Name of vendor/manufacturer of tubing rotator components

    Tubing Rotator Model Model designation of tubing rotator

    Gearbox Vendor Name of vendor/manufacturer of gearbox

    Gearbox Model Catalogue model designation of gearbox

    Gearbox Gear Ratio Gear ratio of gearbox (e.g., 9:1)

    Gearbox Trim Metallurgy, elastomers and coatings

    Gearbox Serial Number(s) Serial number(s) or unique identifiers for that specific gearbox

    Gearbox New/Used/Repaired When installed, was the gearbox New, Used (without service or minor servicing only), or Repaired (used andserviced)

    Gearbox Pull Condition Condition of downhole gearbox when pulled: Reusable or Not Reusable

    Seal Vendor Name of vendor/manufacturer of seal components

    Seal Model Catalogue model designation of seal (e.g. LSBSB-HL)

    Seal Trim Metallurgy, elastomers and coatings

    Seal Serial Number(s) Serial number(s) or unique identifiers for that specific seal

    Seal New/Used/Repaired When installed, was the seal New, Used (without service or minor servicing only), or Repaired (used and service

    Seal Pull Condition Condition of downhole seal when pulled: Reusable or Not Reusable

    Motor Vendor Name of vendor/manufacturer of motor

    Motor Model Catalogue model designation of motor (e.g. KMH)

    Motor Rated Power @ 60Hz Rated horsepower of motor at 60 Hz

    Motor Trim Metallurgy, elastomers and coatings

    Motor Serial Number(s) Serial number(s) or unique identifiers for that specific motor

    IF DH Drive PCP

    System

    IF Rod Driven PCP

    System

    Confidential 2 / 4

  • 7/30/2019 Minimum and General Data Sets

    3/4

    PCP-R IFTS Min&GenDataSets.DRAFT.20050901.Posted.xls General & Minimum Data Sets (8/4/2011) C-FER Technologies

    PCP-RIFTS: General Data Set

    PCP-RIFTS: Min imum Data Set (1)

    Parameter Description

    Motor New/Used/Repaired When installed, was the motor New, Used (without service or minor servicing only), or Repaired (used andserviced)

    Motor Pull Condition Condition of downhole motor when pulled: Reusable or Not Reusable

    Flexshaft Vendor Name of vendor/manufacturer of flexshaft components

    Flexshaft Model Catalogue model designation of flexshaft

    Flexshaft Trim Metallurgy, elastomers and coatings

    Flexshaft Serial Number(s) Serial number(s) or unique identifiers for that specific flexshaft

    Flexshaft New/Used/Repaired When installed, was the flexshaft New, Used (without service or minor servicing only), or Repaired (used and

    serviced)Flexshaft Pull Condition Condition of flexshaft when pulled: Reusable or Not Reusable

    Cable Vendor Name of vendor/manufacturer of cable

    Cable Model Catalogue model designation of cable (e.g., Redalead or CELF)

    Cable Size American Wire Gauge (AWG) size of the cable

    Cable Armour Galvanized, Monel, Stainless Steel, etc.

    Cable Serial Number(s) Serial number(s) or unique identifiers for that specific cable

    Motor Lead Extension (MLE) Model Model designation of motor lead extension (MLE)

    Cable New/Used/RepairedWhen installed, was the cable New, Used (without service or minor servicing only), or Repaired (used and servic

    Cable System Pull Condition Condition of cable system when pulled: Reusable or Not Reusable

    Wellhead Penetrator Model Model designation of wellhead penetrator. Alternatively, wellhead penetrator vendor may be provided.

    Packer Penetrator Model Model designation of packer penetrator. Alternatively, packer penetrator vendor may be provided.

    Downhole Monitoring System Installed?

    Downhole Monitoring System Vendor Was a downhole monitoring system installed with the PCP system? (Yes/No)

    Downhole Monitoring System

    New/Used/Repaired

    When installed, was the downhole monitoring system New, Used (without service or minor servicing only), or

    Repaired (used and serviced)

    Downhole Monitoring System Pull Condition Condition of downhole monitoring system when pulled: Reusable or Not Reusable

    Injection Tubing String Outer Diameter Nominal outer diameter of injection tubing string

    Shroud Installed? Was a shroud installed with the PCP system? (Yes/No)

    Shroud Outer Diameter Outer diameter of shroud. If a shroud is not installed, then leave .

    Packer Installed? Was a packer installed with the PCP system? (Yes/No)

    Packer Depth Top Landed At Measured depth to the top of the packer. If a packer is not installed, then leave .

    Y-tool Installed? Was a Y-Tool installed with the PCP system? (Yes/No)

    Number PCP Systems in Well Number of complete PCP Systems (Motor-Seal-Intake-Pump) installed in the well

    Ifthere were/are more thanone PCP S stems installed,where the installed in arallel orin series(char e um

    (Single/Tandem/Parallel)

    PCP Deployment Method Method used to install/deploy the PCP: Production Tbg, Coiled Tbg, Cable

    First PCP System Installed Well? Was/is this PCP installation the first PCP installed in this well?

    Equipment Comments

    Confidential 3 / 4

  • 7/30/2019 Minimum and General Data Sets

    4/4

    PCP-R IFTS Min&GenDataSets.DRAFT.20050901.Posted.xls General & Minimum Data Sets (8/4/2011) C-FER Technologies

    PCP-RIFTS: General Data Set

    PCP-RIFTS: Min imum Data Set (1)

    Parameter Description

    Total Flow Rate Total Flow Rate of produced liquids at standard conditions

    Pump Speed Pump rotational speed (RP M)

    Torque at Drive Measured torque on the polished rod for surface drive or at motor for downhole drive

    Water Cut Water flow rate by %volume of produced liquids. Alternatively, produced oil and water rates may be provided.

    Pump Intake Pressure Producing pressure at the pump intake

    Producing Fluid Level Measured depth to top of annular fluid level

    Free Gas at Pump IntakeFree gas % by volume at the pump intake pressure and temperature (includes both separated gas and gas hand

    by the pump).

    Wellhead Pressure Pressure of produced fluids at the wellheadCasing Head Pressure Pressure in the casing annulus at the wellhead

    Pump Intake TemperatureProducing fluid temperature at the pump intake. If not provided, Pump Intake Temperature will be assumed equ

    to the Reservoir Temperature.

    Reservoir Static Pressure Static or shut-in pressure at the pump intake

    Gas Oil Ratio (GOR) Producing gas-oil ratio. Alternatively, produced gas rate at standard conditions may be provided.

    Sand CutConcentration of produced sand by %volume of produced liquids and solids. Alternatively, produced sand rate

    be provided. If no sand was produced, please enter zero.

    Total Solids Concentration Total concentration of solids (including sand, scale, particulate, etc.)

    Scale? Presence and relative severity of sale (None/Light/Moderate/Severe)4

    Asphaltenes? Presence and relative severity of asphaltenes (None/ L ight/Moderate/Severe)4

    Solids? Presence and severity of all solids, including sand: None, Yes-Present, Light, Moderate, or Severe4

    CO2 (% by Volume) Concentration of CO2 (preference by %volume of gas). If no CO2 observed, enter zero.

    H2S (% by Volume) Concentration of H2S (preference by %volume of gas). If no H2S observed, enter zero.

    Water pH Acidity of produced water - tends to be indication of corrosivity

    Water Salinity Chloride concentration - indication of water density and corrosivity

    Emulsion? Presence and relative severity of emulsion problem? (None/Light/Moderate/Severe)4Motor Operating Frequency Average frequency (Hz) of power supply to motor; IF surface electric or downhole drive

    Motor Operating Voltage Average voltage of power supply to motor, IF surface electric or downhole drive

    Motor Operating Current Average current of power supply to motor, IF surface electric or downhole drive

    Hydraulic Pressure Average pressure to the hydraulic motor, IF surface electric is a hydraulic drive

    Number of Restarts During Period Total number of starts during the production period

    Injection Fluid Type of injection fluid, if used (water, diluent, oil)

    Injection Fluid Rate Daily rate of injection fluid, if used

    Production Period Comments Corrosion Treatments, etc.

    Any written or verbal procedure, practices E.g., Pump selection and design (elastomer, target in-test efficiency), startup, speed changes, inspection, discaruidelines

    Operating and

    Production Data

    Practices, ,

    manufacture, transportation, inspection,

    installation, operating, pulling and/or failure

    analysis.

    PCP Surveillance System

    (SCADA/Operator/Other)

    Automatic or Manual Control?

    Number General Data Set Parameters = 188

    Number Minimum Data Set Parameters = 70

    Notes:

    2. Duration is the days between Date Period Started and Date Period Ended . Time In Hole is the days between Date Pulled and Date

    Installed .

    3. In PCP-RIFTS, the ESPCP Cable is considered to be a system comprised of the main power cable (insulation, armor, and conductor

    MLE, pothead, splices, packer penetrators, and wellhead penetrator. If any one of these parts is considered Not Reusable, the Cable

    System is considered Not Reusable.

    4. None: substance or problem not observed.

    Yes - P resent: substance or problem is present but the concentration/severity is unknown.

    Light: substance or problem observed but in small amount and not believed to be a problem for ESPs.

    Moderate: moderate amounts of substance or problem observed, may be or has occasionally been a problem.

    Severe: substantial amounts of substance or problem observed, strongly believed or known to be a problem.

    1. Parameters in theMinimum Data Set are highlighted in yellow. Click on buttons labeled "1" and "2" in top left corner of spreadsheet

    flip between Minimum and General Data Sets, respectively (or filter the parameter list based on column "A").

    Confidential 4 / 4