minimum and general data sets
TRANSCRIPT
-
7/30/2019 Minimum and General Data Sets
1/4
PCP-R IFTS Min&GenDataSets.DRAFT.20050901.Posted.xls General & Minimum Data Sets (8/4/2011) C-FER Technologies
PCP-RIFTS: General Data Set
PCP-RIFTS: Min imum Data Set (1)
Parameter DescriptionCompany Name Name of operating company (Participant)
Division Name Name of operating unit, group of field, etc.
Field Name Name of oil field
Field Location (Country) Name of country field is in
Location of PCP Supply Centre Country, Provinces/State, and nearest Town/City of source of PCP system. If more than one supply centre, pleaprovide location of main supply centre.
Location of PCP Teardown Facility Country, Province/State, and nearest Town/City where pulled PCPs are sent for teardown and inspection. If mothan one teardown facility, please provide location of main teardown facility.
Field Type (Onshore/Offshore)Onshore, Offshore (Platform), Offshore (Subsea), Onshore/Offshore
Oil Density at STP Oil density inAPI at standard temperature (15C) and pressure (1 atm)
Reservoir Temperature Fluid temperature at the reservoir conditions
Dead Oil Viscosity at STP Dead oil viscosity at standard temperature (15C) and pressure (1 atm)
Oil Bubble Point Pressure Bubble point (vapour) pressure of oil at Reservoir Temperature
Well Name Name or identifier of well
Well Type (Geometry) Vertical, Slant, Deviated, Horizontal, S idetracked, Re-Entry Sidetrack, or Multilateral
Wellhead location Onshore, Platform, Subsea
Pad or Platform Name Name of group of wells
Reservoir Name/Zone Name(s) of producing reservoirs (during production period)
Reservoir Type Carbonate, Consolidated Sandstone, Unconsolidated Sandstone, Evaporite
Reservoir Recovery Mechanism Aquifer drive, Solution Gas Drive, Water flood, EOR (e.g., CO2 flooding, Water-Alternating-Gas (WAG), PolymeFlood, Steam stimulation, etc)
Completion Type Perforated Casing, Open hole, or Unknown
Sand Control Type Type of sand control installed in the well during the production period, e.g. Gravel Pack, Slotted Liner, Wire-wrapped Screen, etc. If no sand control installed, please indicate None.
Production Casing Outer Diameter Nominal outer diameter of the production casing
Production Period Number Production period number for well
Date Installed (mm/dd/yyyy) Date PCP system was installed
Date Period Started (mm/dd/yyyy) Date PCP system was first started. If not provided, the Date Period Started will be assumed equal to the DateInstalled.
Period Status Status of the production period: Period Completed or Still on Production.
Date Period Ended (mm/dd/yyyy) Date PCP system failed, was shutdown, or last date record was updated if PCP still running. If not provided, theDate Period Ended will be assumed equal to the Date Pulled.
Date Pulled (mm/dd/yyyy) Date PCP system was pulled
Actual Runtime Days the PCP system was actually running. If not provided, Actual Runtime will be assumed equal to Duration
PCP System Failed? Did/has the PCP system failed (Yes or No)? This parameter should be consistent with the Period Status. If PerioFailure Information
Field Information
Fluid Information
Well Information
Runtime Data
(dates)
Status ="Still Running", then PCP System Failed? should be "No". If PCP System Failed? ="Yes", then Period
Status should be "Period Completed".
Reason for Pull: General General category of why the PCP was pulled
Reason for Pull: Specific More specific reason why the PCP was pulled
Primary Failed System Only required if both PCP and Tubing System failed. If only one system fails, then the Primary Failed System isdefaulted to that system.
PCP System - Primary Failed Item The primary failed PCP component or partPCP System - Primary Failure Descriptor The primary descriptor of the PCP System - Primary Failed Item
PCP System - Secondary Failure Descriptor The secondary descriptor of the PCP System - Primary Failed Item
PCP System - Failure Cause: General Circumstances during design, manufacture or use that led to the PCP System failure
PCP System - Failure Cause: Specific Specific circumstances during design, manufacture or use that led to the PCP System failure
PCP System - Contributing Cause: General Circumstances during design, manufacture or use that contributed to the PCP System failure
PCP System - Contributing Cause: Specific Specific circumstances during design, manufacture or use that contributed to the PCP System failure
Tubing System Failed? Did/has the Tubing System failed?
Tubing System - Primary Failed Item The primary failed Tubing component or part
Tubing System - Primary Failure Descriptor The primary descriptor of the Tubing System - Primary Failed Item
Tubing System - Secondary Failure Descriptor The secondary descriptor of the Tubing System - Primary Failed Item
Tubing System - Failure Cause: General Circumstances during design, manufacture or use that led to the Tubing System failure
Tubing System - Failure Cause: Specific Specific circumstances during design, manufacture or use that led to the Tubing System failure
Tubing System - Contributing Cause: General Circumstances during design, manufacture or use that contributed to the Tubing System failure
Tubing System - Contributing Cause: Specific Specific circumstances during design, manufacture or use that contributed to the Tubing System failure
Failure Comments Specific notes regarding the failure. Include a description of the "contaminant" (e.g., sand, scale, asphaltene, etcthe Contaminated failure descriptor is used.
Control Panel Type Type of control panel: Switchboard, Switchboard with Soft Start, Variable Frequency Drive
Control Panel Vendor Vendor of control panel
Power Transmission Type Type of power transmission: Belts and Sheaves, Gears, Combination, or Other
Prime Mover Type Type of prime mover: Electric Motor, Internal Combustion Engine, or Hydraulic Motor.
Drivehead Vendor Name of vendor/manufacturer of surface drivehead
Prime Mover Rated Power Rated power of prime mover on surface drive
Power Source Local Power Line/Grid, Field Generator, Wellsite Generator
Power Quality Excellent, Good, Average, Low, Poor
(as per PCP
Failure
Nomenclature
Standard)
Surface
Equipment Data
IF Rod Driven PCP
System
Confidential 1 / 4
-
7/30/2019 Minimum and General Data Sets
2/4
PCP-R IFTS Min&GenDataSets.DRAFT.20050901.Posted.xls General & Minimum Data Sets (8/4/2011) C-FER Technologies
PCP-RIFTS: General Data Set
PCP-RIFTS: Min imum Data Set (1)
Parameter Description
PCP Vendor Name of vendor/manufacturer of pump components (e.g., Weatherford BMW). If rotor vendor and stator vendordifferent, use the stator vendor as the Pump Vendor.
Pump Model (SI) Catalogue model designation of pump (e.g., 15-1400)
Elastomer Model Model designation of stator elastomer
Elastomer Type Type of stator elastomer (e.g., medium nitrile, high nitrile, fluroelastomer, etc.)
Rotor Coating Type Type of rotor coating (e.g. chrome, boron, etc.)
Pump Rated Displacement Rated displacement of the pump
Pump Rated Differential Pressure Rated differential pressure of the pump
Stator Serial Number Serial number or unique identifiers for that specific PCP statorRotor Serial Number Serial number or unique identifiers for that specific PC P rotor
In-Test: Date Date pump was bench tested prior to installation
In-Test: Speed Rotational speed pump was bench tested at (RPM) prior to installation
In-Test: Reference Differential Pressure Reference pressure of bench test volumetric efficiency (usually rated pressure) prior to installation
In-Test: Volumetric Efficiency at Reference DP Volumetric efficiency of pump at reference pressure and test speed prior to installation
In-Test: Friction Torque Friction torque of pump at test speed prior to installation
In-Test: Volumetric Efficiency at Zero DP Volumetric efficiency of pump at zero differential pressure prior to installation
Out-Test: Date Date pump was bench tested after pull
Out-Test: Speed Rotational speed pump was bench tested at (RPM) after pull
Out-Test: Reference Differential Pressure Reference pressure of bench test volumetric efficiency (usually rated pressure) after pull
Out-Test: Volumetric Efficiency at Reference
DP
Volumetric efficiency of pump at reference pressure and test speed after pull
Out-Test: Friction Torque Friction torque of pump at test speed after pull
Out-Test: Volumetric Efficiency at Zero DP Volumetric efficiency of pump at zero differential pressure after pull
Date Pump Inspected Date pump was inspectedStator New/Used/Repaired When installed, was the stator New or Used (without service or minor servicing only)
Rotor New/Used/Rechromed When installed, was the rotor New, Used (without service or minor servicing only), Repaired (used and servicedRechromed
Stator Pull Condition Condition of stator when pulled: Reusable or Not Reusable
Rotor Pull Condition Condition of rotor when pulled: Reusable or Not Reusable
Pump Intake Vendor Name of vendor/manufacturer of pump intake
Pump Intake TypeType of pump intake: None (PCP Opening), Tail Pipe, Standard Bolt-on Intake (Flexshaft), Static Gas Separator
Bottom-Feeder Gas Separator, Multiple Stator Intakes, Rotary Gas Separator, or Gas Handler
Pump Intake Pull Condition Condition of pump intake when pulled: Reusable or Not Reusable
Tag Bar Type Type of pump tag bar (e.g., integral bar or plate or separate downhole component)
Downhole
Equipment Data
Tag Bar Pull Condition Condition of tag bar when pulled: Reusable or Not Reusable
Pump Seating Depth MD Measured depth of the pump intake
Pump Seating Depth TVD Vertical depth of the pump intake
Inclination at PSD Inclination (hole angle) at the Pump Seating Depth
Maximum Dogleg Maximum curvature that the PCP had to pass through during installation
Tubing Outer Diameter Nominal outer diameter of production tubing
Tubing Weight Weight of the production tubing
Tubing Internal Coating Type Coating type on ID of production tubing string, if tubing ID is coated
Rod Diameter Nominal diameter of rod string
Rod Material Grade Material grade of rod string
Rod Type Type of rod string: Standard, Continuous, or Hollow
Rod Centralizer Type Type of rod string coupling centralizers, if used (Coated, Spin Thru)
Rod Guide Type Type of rod string rod body guides, if used
Tubing Anchor Installed? Was a device installed to anchor the tubing to the casing?
Tubing Anchor Model Model designation of torque anchor. Alternatively, torque anchor vendor may be provided.
Tubing Rotator Installed? Was a device installed to rotate the tubing?
Tubing Rotator Vendor Name of vendor/manufacturer of tubing rotator components
Tubing Rotator Model Model designation of tubing rotator
Gearbox Vendor Name of vendor/manufacturer of gearbox
Gearbox Model Catalogue model designation of gearbox
Gearbox Gear Ratio Gear ratio of gearbox (e.g., 9:1)
Gearbox Trim Metallurgy, elastomers and coatings
Gearbox Serial Number(s) Serial number(s) or unique identifiers for that specific gearbox
Gearbox New/Used/Repaired When installed, was the gearbox New, Used (without service or minor servicing only), or Repaired (used andserviced)
Gearbox Pull Condition Condition of downhole gearbox when pulled: Reusable or Not Reusable
Seal Vendor Name of vendor/manufacturer of seal components
Seal Model Catalogue model designation of seal (e.g. LSBSB-HL)
Seal Trim Metallurgy, elastomers and coatings
Seal Serial Number(s) Serial number(s) or unique identifiers for that specific seal
Seal New/Used/Repaired When installed, was the seal New, Used (without service or minor servicing only), or Repaired (used and service
Seal Pull Condition Condition of downhole seal when pulled: Reusable or Not Reusable
Motor Vendor Name of vendor/manufacturer of motor
Motor Model Catalogue model designation of motor (e.g. KMH)
Motor Rated Power @ 60Hz Rated horsepower of motor at 60 Hz
Motor Trim Metallurgy, elastomers and coatings
Motor Serial Number(s) Serial number(s) or unique identifiers for that specific motor
IF DH Drive PCP
System
IF Rod Driven PCP
System
Confidential 2 / 4
-
7/30/2019 Minimum and General Data Sets
3/4
PCP-R IFTS Min&GenDataSets.DRAFT.20050901.Posted.xls General & Minimum Data Sets (8/4/2011) C-FER Technologies
PCP-RIFTS: General Data Set
PCP-RIFTS: Min imum Data Set (1)
Parameter Description
Motor New/Used/Repaired When installed, was the motor New, Used (without service or minor servicing only), or Repaired (used andserviced)
Motor Pull Condition Condition of downhole motor when pulled: Reusable or Not Reusable
Flexshaft Vendor Name of vendor/manufacturer of flexshaft components
Flexshaft Model Catalogue model designation of flexshaft
Flexshaft Trim Metallurgy, elastomers and coatings
Flexshaft Serial Number(s) Serial number(s) or unique identifiers for that specific flexshaft
Flexshaft New/Used/Repaired When installed, was the flexshaft New, Used (without service or minor servicing only), or Repaired (used and
serviced)Flexshaft Pull Condition Condition of flexshaft when pulled: Reusable or Not Reusable
Cable Vendor Name of vendor/manufacturer of cable
Cable Model Catalogue model designation of cable (e.g., Redalead or CELF)
Cable Size American Wire Gauge (AWG) size of the cable
Cable Armour Galvanized, Monel, Stainless Steel, etc.
Cable Serial Number(s) Serial number(s) or unique identifiers for that specific cable
Motor Lead Extension (MLE) Model Model designation of motor lead extension (MLE)
Cable New/Used/RepairedWhen installed, was the cable New, Used (without service or minor servicing only), or Repaired (used and servic
Cable System Pull Condition Condition of cable system when pulled: Reusable or Not Reusable
Wellhead Penetrator Model Model designation of wellhead penetrator. Alternatively, wellhead penetrator vendor may be provided.
Packer Penetrator Model Model designation of packer penetrator. Alternatively, packer penetrator vendor may be provided.
Downhole Monitoring System Installed?
Downhole Monitoring System Vendor Was a downhole monitoring system installed with the PCP system? (Yes/No)
Downhole Monitoring System
New/Used/Repaired
When installed, was the downhole monitoring system New, Used (without service or minor servicing only), or
Repaired (used and serviced)
Downhole Monitoring System Pull Condition Condition of downhole monitoring system when pulled: Reusable or Not Reusable
Injection Tubing String Outer Diameter Nominal outer diameter of injection tubing string
Shroud Installed? Was a shroud installed with the PCP system? (Yes/No)
Shroud Outer Diameter Outer diameter of shroud. If a shroud is not installed, then leave .
Packer Installed? Was a packer installed with the PCP system? (Yes/No)
Packer Depth Top Landed At Measured depth to the top of the packer. If a packer is not installed, then leave .
Y-tool Installed? Was a Y-Tool installed with the PCP system? (Yes/No)
Number PCP Systems in Well Number of complete PCP Systems (Motor-Seal-Intake-Pump) installed in the well
Ifthere were/are more thanone PCP S stems installed,where the installed in arallel orin series(char e um
(Single/Tandem/Parallel)
PCP Deployment Method Method used to install/deploy the PCP: Production Tbg, Coiled Tbg, Cable
First PCP System Installed Well? Was/is this PCP installation the first PCP installed in this well?
Equipment Comments
Confidential 3 / 4
-
7/30/2019 Minimum and General Data Sets
4/4
PCP-R IFTS Min&GenDataSets.DRAFT.20050901.Posted.xls General & Minimum Data Sets (8/4/2011) C-FER Technologies
PCP-RIFTS: General Data Set
PCP-RIFTS: Min imum Data Set (1)
Parameter Description
Total Flow Rate Total Flow Rate of produced liquids at standard conditions
Pump Speed Pump rotational speed (RP M)
Torque at Drive Measured torque on the polished rod for surface drive or at motor for downhole drive
Water Cut Water flow rate by %volume of produced liquids. Alternatively, produced oil and water rates may be provided.
Pump Intake Pressure Producing pressure at the pump intake
Producing Fluid Level Measured depth to top of annular fluid level
Free Gas at Pump IntakeFree gas % by volume at the pump intake pressure and temperature (includes both separated gas and gas hand
by the pump).
Wellhead Pressure Pressure of produced fluids at the wellheadCasing Head Pressure Pressure in the casing annulus at the wellhead
Pump Intake TemperatureProducing fluid temperature at the pump intake. If not provided, Pump Intake Temperature will be assumed equ
to the Reservoir Temperature.
Reservoir Static Pressure Static or shut-in pressure at the pump intake
Gas Oil Ratio (GOR) Producing gas-oil ratio. Alternatively, produced gas rate at standard conditions may be provided.
Sand CutConcentration of produced sand by %volume of produced liquids and solids. Alternatively, produced sand rate
be provided. If no sand was produced, please enter zero.
Total Solids Concentration Total concentration of solids (including sand, scale, particulate, etc.)
Scale? Presence and relative severity of sale (None/Light/Moderate/Severe)4
Asphaltenes? Presence and relative severity of asphaltenes (None/ L ight/Moderate/Severe)4
Solids? Presence and severity of all solids, including sand: None, Yes-Present, Light, Moderate, or Severe4
CO2 (% by Volume) Concentration of CO2 (preference by %volume of gas). If no CO2 observed, enter zero.
H2S (% by Volume) Concentration of H2S (preference by %volume of gas). If no H2S observed, enter zero.
Water pH Acidity of produced water - tends to be indication of corrosivity
Water Salinity Chloride concentration - indication of water density and corrosivity
Emulsion? Presence and relative severity of emulsion problem? (None/Light/Moderate/Severe)4Motor Operating Frequency Average frequency (Hz) of power supply to motor; IF surface electric or downhole drive
Motor Operating Voltage Average voltage of power supply to motor, IF surface electric or downhole drive
Motor Operating Current Average current of power supply to motor, IF surface electric or downhole drive
Hydraulic Pressure Average pressure to the hydraulic motor, IF surface electric is a hydraulic drive
Number of Restarts During Period Total number of starts during the production period
Injection Fluid Type of injection fluid, if used (water, diluent, oil)
Injection Fluid Rate Daily rate of injection fluid, if used
Production Period Comments Corrosion Treatments, etc.
Any written or verbal procedure, practices E.g., Pump selection and design (elastomer, target in-test efficiency), startup, speed changes, inspection, discaruidelines
Operating and
Production Data
Practices, ,
manufacture, transportation, inspection,
installation, operating, pulling and/or failure
analysis.
PCP Surveillance System
(SCADA/Operator/Other)
Automatic or Manual Control?
Number General Data Set Parameters = 188
Number Minimum Data Set Parameters = 70
Notes:
2. Duration is the days between Date Period Started and Date Period Ended . Time In Hole is the days between Date Pulled and Date
Installed .
3. In PCP-RIFTS, the ESPCP Cable is considered to be a system comprised of the main power cable (insulation, armor, and conductor
MLE, pothead, splices, packer penetrators, and wellhead penetrator. If any one of these parts is considered Not Reusable, the Cable
System is considered Not Reusable.
4. None: substance or problem not observed.
Yes - P resent: substance or problem is present but the concentration/severity is unknown.
Light: substance or problem observed but in small amount and not believed to be a problem for ESPs.
Moderate: moderate amounts of substance or problem observed, may be or has occasionally been a problem.
Severe: substantial amounts of substance or problem observed, strongly believed or known to be a problem.
1. Parameters in theMinimum Data Set are highlighted in yellow. Click on buttons labeled "1" and "2" in top left corner of spreadsheet
flip between Minimum and General Data Sets, respectively (or filter the parameter list based on column "A").
Confidential 4 / 4