ministry of works and human settlement · 2014-08-04 · services under the ministry of works and...
TRANSCRIPT
MINISTRY OF WORKS AND HUMAN SETTLEMENT
DEPARTMENT OF ENGINEERING SERVICES LABOUR AND MATERIAL CO-EFFICIENTS
(ELECTRICAL) 2013
Labour and Material Coefficients (Electrical) - 2013
Foreword
The Labour and Material Co-efficient (LMC) published by the Department of EngineeringServices under the Ministry of Works and Human Settlement forms an integral part of BhutanSchedule of Rates. The built-up rates of the BSR are corresponding to the coefficients asindicated in this document.
This book is a guideline for preparation of rate analysis for those items of work which are similarin nature. Due to rapid change in construction technology, a need to review and updatemachinery and labour coefficient is also felt. Until such system is established where latest bestpractices can be easily adopted, LMC shall continue to remain unchanged. However,individuals/agencies are advised to carefully review the coefficients and apply it at their owndiscretions.
I am positive ~hat this Analysis of Rates will be useful to all concerned.
Dr. Sonam TenzinSecretary,Ministry of Works and Human SettlementThimphu.
Date: ~~ 10> \ 'U) I~
Department of Engineering Services page 3
Labour and Material Coefficients (Electrical) - 2013
Department of Engineering Services page 4
Disclaimer
The BSR (Both Civil & Electrical) ‐2013 is prepared and published primarily as a tool to assist in
estimation of project costs. Due to difficulty in obtaining comprehensive and accurate rates from
FOUR base towns, and associated complexity in their analysis, the BSR reflects only suggestive
averages and not accurate current market rates. Material and labour rates are subject to change any
time as they are totally governed by market forces which are beyond the control of any
individual/group/organization. The validity of rates in the BSR is therefore uncertain and by the
time of publication of this book, some rates would have already altered. Hence engineers,
architects, contractors and all other relevant professionals/firms in the construction industry are
advised to carry out thorough assessment of materials to be used and after conducting their own
market studies, analyse the rates and prepare cost estimates. The publisher shall not be held
accountable or answerable for any issues/disputes arising as a result of individuals or agencies using
the rates in the BSR‐2013 as a basis for filling their bids, evaluating and awarding of tenders.
Furthermore, the BSR shall not be used for purpose of any contractual payments.
©All rights reserved with DES, MoWHS. Reproduction for sale of this publication, in part(s) or
whole, in any form or by any means, by any agency or individual, is a punishable offence and is
strictly prohibited.
Labour and Material Coefficients (Electrical)- 2013
Department of Engineering Services, MoWHS
CONTENTS
1 Foreword 3
2 Disclaimer 4
3 PVC Casing & Capping Wiring 7
4 Trunking Cable Management Wiring 26
5 MS Conduit Wiring 33
6 PVC Conduit Wiring 66
7 Stainless Steel Conduit Wiring 103
8 Re-Wiring 120
9 Conduiting 135
10 Boxes 159
11 Switches & Sockets 165
12 Indoor Luminiaries (Supply) 179
13 Outdoor Luminiaries (Supply) 183
14 Lamps & Shades 187
15 Fans (Supply) 191
16 Control Gear & Busbars (Supply) 192
17 Erection / Installation 213
18 Earthing 230
19 Lightning Protection 234
20 Power Cable (Supply) 235
21 Laying of Power Cable 250
22 Control Cable 257
23 Electric Pole & Accessories 268
24 Telephone Wires & Cables 272
25 Air Conditioners 273
26 Dismantling & Demolition 274
27 Civil Works 275
Chapter Description Page
Labour and Material Coefficients (Electrical)- 2013 Page 7
Department of Engineering Services, MoWHS
WP0001
Coefficient for per m of WP0001
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 1.01 m
WP0002
Coefficient for per m of WP0002
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 2.02 m
WP0003
Coefficient for per m of WP0003
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 3.03 m
WP0004
Coefficient for per m of WP0004
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 4.04 m
WP0005
Coefficient for per m of WP0005
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 5.05 m
WP0006
Coefficient for per m of WP0006
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 6.06 m
WP0007
Coefficient for per m of WP0007
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 7.07 m
CHAPTER 1: PVC CASING & CAPPING WIRING
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 4x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 5x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 6x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 1x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 3x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 2x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 7x1.5 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 8
Department of Engineering Services, MoWHS
WP0008
Coefficient for per m of WP0008
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 8.08 m
WP0009
Coefficient for per m of WP0009
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 2.02 m
WP0010
Coefficient for per m of WP0010
Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 3.03 m
WP0011
Coefficient for per m of WP0011
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 4.04 m
WP0012
Coefficient for per m of WP0012
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 5.05 m
WP0013
Coefficient for per m of WP0013
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 6.06 m
WP0014
Coefficient for per m of WP0014
Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 2.02 m
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 5x2.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 6x2.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 2x4 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 3x2.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 4x2.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 8x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 2x2.5 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 9
Department of Engineering Services, MoWHS
WP0015
Coefficient for per m of WP0015
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 3.03 m
WP0016
Coefficient for per m of WP0016
Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.027 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 4.04 m
WP0017
Coefficient for per m of WP0017
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 5.05 m
WP0018
Coefficient for per m of WP0018
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 2.02 m
WP0019
Coefficient for per m of WP0019
Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.027 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 3.0302 m
WP0020
Coefficient for per m of WP0020
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 4.04 m
WP0040
Coefficient for per m of WP0040
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 1.01 m
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 4x6 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 1x1 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 5x4 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 3x4 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 4x4 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 2x6 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 3x6 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 10
Department of Engineering Services, MoWHS
WP0041
Coefficient for per m of WP0041
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m
WP0042
Coefficient for per m of WP0042
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 3.03 m
WP0043
Coefficient for per m of WP0043
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.04 m
WP0044
Coefficient for per m of WP0044
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 5.05 m
WP0045
Coefficient for per m of WP0045
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.06 m
WP0046
Coefficient for per m of WP0046
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 7.07 m
WP0047
Coefficient for per m of WP0047
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 8.08 m
WP0048
Coefficient for per m of WP0048
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 9.09 m
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 3x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 4x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 5x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 6x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 7x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 2x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 8x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 9x1 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 11
Department of Engineering Services, MoWHS
WP0049
Coefficient for per m of WP0049
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m
WP0050
Coefficient for per m of WP0050
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 3.03 m
WP0051
Coefficient for per m of WP0051
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.04 m
WP0052
Coefficient for per m of WP0052
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 5.05 m
WP0053
Coefficient for per m of WP0053
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.06 m
WP0054
Coefficient for per m of WP0054
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 7.07 m
WP0055
Coefficient for per m of WP0055
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 8.08 m
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 4x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 5x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 6x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 7x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 2x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 3x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 8x1.5 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 12
Department of Engineering Services, MoWHS
WP0056
Coefficient for per m of WP0056
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m
WP0057
Coefficient for per m of WP0057
Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 3.03 m
WP0058
Coefficient for per m of WP0058
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.04 m
WP0059
Coefficient for per m of WP0059
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 5.05 m
WP0060
Coefficient for per m of WP0060
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 6.06 m
WP0061
Coefficient for per m of WP0060
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m
WP0062
Coefficient for per m of WP0062
Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 3.03 m
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 5x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 6x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 2x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 3x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 2x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 3x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 4x2 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 13
Department of Engineering Services, MoWHS
WP0063
Coefficient for per m of WP0063
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.04 m
WP0064
Coefficient for per m of WP0064
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 5.05 m
WP0065
Coefficient for per m of WP0065
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 6.06 m
WP0066
Coefficient for per m of WP0066
Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m
WP0067
Coefficient for per m of WP0067
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 3.03 m
WP0068
Coefficient for per m of WP0068
Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.027 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.04 m
WP0069
Coefficient for per m of WP0069
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 5.05 m
WP0070
Coefficient for per m of WP0070
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 3x4 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 4x4 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 5x4 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 2x6 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 4x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 5x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 6x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 2x4 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 14
Department of Engineering Services, MoWHS
WP0071
Coefficient for per m of WP0071
Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.027 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 3.0302 m
WP0072
Coefficient for per m of WP0072
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m
Coefficient for per point of WP0095
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WP0096
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
WP0095
WP0096etc. as required - Medium Point
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 3x6 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 4x6 sq.mm
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - Short Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning
Labour and Material Coefficients (Electrical)- 2013 Page 15
Department of Engineering Services, MoWHS
Coefficient for per point of WP0097
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WP0105
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
etc. as required - Medium Point Coefficient for per point of WP0106
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
WP0106
WP0097
WP0105Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning
etc. as required - Long Point
etc. as required - Short Point
Labour and Material Coefficients (Electrical)- 2013 Page 16
Department of Engineering Services, MoWHS
Coefficient for per point of WP0107
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WP0115
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WP0116
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each
WP0107
WP0115
etc. as required - Long Point
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including
earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
WP0116earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning
Labour and Material Coefficients (Electrical)- 2013 Page 17
Department of Engineering Services, MoWHS
Coefficient for per point of WP0117
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WP0125
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4941 PVC Casing & Cappings - 12x10 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WP0126
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4941 PVC Casing & Cappings - 12x10 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3/5 pin, 6 ampere socket outlet and switch
WP0125
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3/5 pin, 6 ampere socket outlet and switch
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WP0126
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3/5 pin, 6 ampere socket outlet and switch includingWP0117earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
Labour and Material Coefficients (Electrical)- 2013 Page 18
Department of Engineering Services, MoWHS
Coefficient for per point of WP0127
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4941 PVC Casing & Cappings - 12x10 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WP0135
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m
MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WP0136
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m
MT5825 Plate 4-module with frame 1 each
WP0135
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3 pin, 6/16 ampere socket outlet and switch
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3/5 pin, 6 ampere socket outlet and switch
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
WP0136
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
WP0127
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3 pin, 6/16 ampere socket outlet and switch
Labour and Material Coefficients (Electrical)- 2013 Page 19
Department of Engineering Services, MoWHS
Coefficient for per point of WP0137
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WP0145
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WP0146
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each
WP0137
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
WP0145
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WP0146
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3 pin, 6/16 ampere socket outlet and switchincluding earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
Labour and Material Coefficients (Electrical)- 2013 Page 20
Department of Engineering Services, MoWHS
Coefficient for per point of WP0147
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WP0155
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WP0156
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each
WP0147
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
WP0155
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WP0156
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required- Long Point
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3 pin, 16 ampere socket outlet and switch
Labour and Material Coefficients (Electrical)- 2013 Page 21
Department of Engineering Services, MoWHS
Coefficient for per point of WP0157
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WP0165
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WP0166
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each
Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WP0166
WP0165Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with 2 way 6 ampere switch including earthing third pin, connections, painting, testing, and
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
WP0157
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3 pin, 16 ampere socket outlet and switch
commissioning etc. as required - Short Point
Labour and Material Coefficients (Electrical)- 2013 Page 22
Department of Engineering Services, MoWHS
Coefficient for per point of WP0167
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WP0175
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WP0176
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Medium Point
WP0176
Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with 2 way 6 ampere switch including earthing third pin, connections, painting, testing
commissioning etc. as required - Short Point WP0175
and commissioning etc. as required - Long Point WP0167
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with 2 way 6 ampere switch including connections, painting, testing and
Labour and Material Coefficients (Electrical)- 2013 Page 23
Department of Engineering Services, MoWHS
Coefficient for per point of WP0177
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per m of WP0185
Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4940 PVC Casing & Cappings - 12x12 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m
Coefficient for per m of WP0186
Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4940 PVC Casing & Cappings - 12x12 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m
Coefficient for per m of WP0187
Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4944 PVC Casing & Cappings - 20x12 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m
required - 2x1.5 sq.mm WP0186
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm
WP0187
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as
required - 2x1 sq.mm WP0185
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Long Point
WP0177
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as
Labour and Material Coefficients (Electrical)- 2013 Page 24
Department of Engineering Services, MoWHS
WP0195
Coefficient for per m of WP0195
Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4940 PVC Casing & Cappings - 12x12 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m
WP0196
Coefficient for per m of WP0196
Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4944 PVC Casing & Cappings - 20x12 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m
WP0200
Coefficient for per m of WP0200
Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4944 PVC Casing & Cappings - 20x12 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m
WP0205
Coefficient for per m of WP0205
Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4945 PVC Casing & Cappings - 25x10 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 2x6 sq.mm
Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 2x2 sq.mm
Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 2x2.5 sq.mm
Wiring for power circuit with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 25
Department of Engineering Services, MoWHS
WP0206
Coefficient for per m of WP0206
Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4945 PVC Casing & Cappings - 25x10 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m
WP0207
Coefficient for per m of WP0207
Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4945 PVC Casing & Cappings - 25x10 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m
WP0208
Coefficient for per m of WP0208
Code Description Quant Units LB0051 Mason Gd.2 0.0242 day LB0056 Wireman Gd.1 0.0534 day LB0067 Painter Gd.2 0.0266 day LB0069 Wireman Gd.2 0.0776 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m MT4873 PVC sleev 25mm 6.7 each MT4946 PVC Casing & Cappings - 30x10 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m
WP0209
Coefficient for per m of WP0209
Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.067 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 4.04 m MT4873 PVC sleev 25mm 6.7 each MT4948 PVC Casing & Cappings - 50x20 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 2x10 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 2x16 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 4x10 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 4x6 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 26
Department of Engineering Services, MoWHS
WP0210
Coefficient for per m of WP0210
Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.067 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4.04 m MT4873 PVC sleev 25mm 6.7 each MT4948 PVC Casing & Cappings - 50x20 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m
CM0001
Coefficient for per m of CM0001
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4071 PVC insulated single core copper conductor, 1.1KVG - 1.5 sq.mm 2.02 m
CM0002
Coefficient for per m of CM0002
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4071 PVC insulated single core copper conductor, 1.1KVG - 1.5 sq.mm 3.03 m
CM0003
Coefficient for per m of CM0003
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated single core copper conductor, 1.1KVG - 1.5 sq.mm 4.04 m
CM0004
Coefficient for per m of CM0004
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated single core copper conductor, 1.1KVG - 1.5 sq.mm 5.05 m
CM0005
Coefficient for per m of CM0005
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated single core copper conductor, 1.1KVG - 1.5 sq.mm 6.06 m
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 4x16 sq.mm
CHAPTER 2: TRUNKING CABLE MANAGEMENT-WIRING
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 6x1.5 sq.mm
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 2x1.5 sq.mm
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 3x1.5 sq.mm
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 4x1.5 sq.mm
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 5x1.5 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 27
Department of Engineering Services, MoWHS
CM0006
Coefficient for per m of CM0006
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4071 PVC insulated single core copper conductor, 1.1KVG - 1.5 sq.mm 7.07 m
CM0007
Coefficient for per m of CM0007
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4071 PVC insulated single core copper conductor, 1.1KVG - 1.5 sq.mm 8.08 m
CM0008
Coefficient for per m of CM0008
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4073 PVC insulated single core copper conductor, 1.1KVG - 2.5 sq.mm 2.02 m
CM0009
Coefficient for per m of CM0009
Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4073 PVC insulated single core copper conductor, 1.1KVG - 2.5 sq.mm 3.03 m
CM0010
Coefficient for per m of CM0010
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated single core copper conductor, 1.1KVG - 2.5 sq.mm 4.04 m
CM0011
Coefficient for per m of CM0011
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated single core copper conductor, 1.1KVG - 2.5 sq.mm 5.05 m
CM0012
Coefficient for per m of CM0012
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4073 PVC insulated single core copper conductor, 1.1KVG - 2.5 sq.mm 6.06 m
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 7x1.5 sq.mm
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 8x1.5 sq.mm
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 2x2.5 sq.mm
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 3x2.5 sq.mm
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 4x2.5 sq.mm
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 5x2.5 sq.mm
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 6x2.5 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 28
Department of Engineering Services, MoWHS
CM0013
Coefficient for per m of CM0013
Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4074 PVC insulated single core copper conductor, 1.1KVG - 4.0 sq.mm 2.02 m
CM0014
Coefficient for per m of CM0014
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4074 PVC insulated single core copper conductor, 1.1KVG - 4.0 sq.mm 3.03 m
CM0015
Coefficient for per m of CM0015
Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.027 day MT4074 PVC insulated single core copper conductor, 1.1KVG - 4.0 sq.mm 4.04 m
CM0016
Coefficient for per m of CM0016
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4074 PVC insulated single core copper conductor, 1.1KVG - 4.0 sq.mm 5.05 m
CM0017
Coefficient for per m of CM0017
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4075 PVC insulated single core copper conductor, 1.1KVG - 6.0 sq.mm 2.02 m
CM0018
Coefficient for per m of CM0018
Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.027 day MT4075 PVC insulated single core copper conductor, 1.1KVG - 6.0 sq.mm 3.03 m
CM0019
Coefficient for per m of CM0019
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4075 PVC insulated single core copper conductor, 1.1KVG - 6.0 sq.mm 4.04 m
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 5x4.0 sq.mm
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 2x6.0 sq.mm
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 3x6.0 sq.mm
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 4x6.0 sq.mm
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 4x4.0 sq.mm
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 3x4.0 sq.mm
Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 2x4.0 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 29
Department of Engineering Services, MoWHS
CM0050
Coefficient for per point of CM0050
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor 1.1KVG - 1.5 sq.mm 4.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7000 PVC mini-trunking - 32x12.5 mm 2 m MT7002 Changeable internal/external angle 1 each
MT7003 Changeble flat angle 1 eachMT7001 End caps 0.1 each
MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
CM0051
Coefficient for per point of CM0051
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor 1.1KVG - 1.5 sq.mm 10.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7000 PVC mini-trunking - 32x12.5 mm 5 m MT7002 Changeable internal/external angle 1 each
MT7003 Changeble flat angle 1 eachMT7001 End caps 0.2 each
MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
CM0052
Coefficient for per point of CM0052
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor 1.1KVG - 1.5 sq.mm 17.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7000 PVC mini-trunking - 32x12.5 mm 8.5 m MT7002 Changeable internal/external angle 1 each
MT7003 Changeble flat angle 1 eachMT7001 End caps 0.5 each
MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking including connections, painting, testing and commissioning etc. as required - Long Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking including connections, painting, testing and commissioning etc. as required - Short Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking including connections, painting, testing and commissioning etc. as required - Medium Point
Labour and Material Coefficients (Electrical)- 2013 Page 30
Department of Engineering Services, MoWHS
Coefficient for per point of CM0053
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4073 PVC insulated Single Core Copper conductor 1.1KVG - 2.5 sq.mm 4.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7000 PVC mini-trunking - 32x12.5 mm 2 m MT7002 Changeable internal/external angle 1 each
MT7003 Changeble flat angle 1 eachMT7001 End caps 0.1 eachMT6537 Wire - 2.5 mm dia. bare copper 2.4 m
MT5800 6A switch SP 1-way 1 eachMT5809 3-pin, 6A socket outlet, shuttered 1 each
MT5824 Plate 3-module with frame 1 each
Coefficient for per point of CM0054
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4073 PVC insulated Single Core Copper conductor 1.1KVG - 2.5 sq.mm 10.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7000 PVC mini-trunking - 32x12.5 mm 5 m MT7002 Changeable internal/external angle 1 each
MT7003 Changeble flat angle 1 eachMT7001 End caps 0.2 eachMT6537 Wire - 2.5 mm dia. bare copper 5.4 mMT5809 3-pin, 6A socket outlet, shuttered 1 each
MT5800 6A switch SP 1-way 1 each MT5824 Plate 3-module with frame 1 each
Coefficient for per point of CM0055
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4073 PVC insulated Single Core Copper conductor 1.1KVG - 2.5 sq.mm 17.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7000 PVC mini-trunking - 32x12.5 mm 8.5 m MT7002 Changeable internal/external angle 1 each
MT7003 Changeble flat angle 1 eachMT7001 End caps 0.5 eachMT6537 Wire - 2.5 mm dia. bare copper 8.9 mMT5809 3-pin, 6A socket outlet, shuttered 1 each
MT5800 6A switch SP 1-way 1 each MT5824 Plate 3-module with frame 1 each
CM0055
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking with providing and fixing 3/5 pin, 6 ampere socket outlet and switchincluding earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
CM0054
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking with providing and fixing 3/5 pin, 6 ampere socket outlet and switchincluding earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
CM0053
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking with providing and fixing 3/5 pin, 6 ampere socket outlet and switchincluding earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
Labour and Material Coefficients (Electrical)- 2013 Page 31
Department of Engineering Services, MoWHS
Coefficient for per point of CM0056
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor 1.1KVG - 4.0 sq.mm 4.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7005 PVC mini-trunking - 32x16 mm 2 m MT7007 Changeable internal/external angle 1 each
MT7008 Changeble flat angle 1 eachMT7006 End caps 0.1 eachMT6537 Wire - 2.5 mm dia. bare copper 2.4 mMT5814 5/6 pin, 6/16 A socket outlet, shuttered 1 each
MT5800 6A switch SP 1-way 1 each MT5825 Plate 4-module with frame 1 each
Coefficient for per point of CM0057
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor 1.1KVG - 4.0 sq.mm 10.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7005 PVC mini-trunking - 32x16 mm 5 m MT7007 Changeaable internal/external angle 1 each
MT7008 Changeble flat angle 1 eachMT7006 End caps 0.2 eachMT6537 Wire - 2.5 mm dia. bare copper 5.4 mMT5814 5/6 pin, 6/16 A socket outlet, shuttered 1 each
MT5800 6A switch SP 1-way 1 each MT5825 Plate 4-module with frame 1 each
Coefficient for per point of CM0058
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor 1.1KVG - 4.0 sq.mm 17.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7005 PVC mini-trunking - 32x16 mm 8.5 m MT7007 Changeable internal/external angle 1 each
MT7008 Changeble flat angle 1 eachMT7006 End caps 0.5 eachMT6537 Wire - 2.5 mm dia. bare copper 8.9 mMT5814 5/6 pin, 6/16 A socket outlet, shuttered 1 each
MT5800 6A switch SP 1-way 1 each MT5825 Plate 4-module with frame 1 each
CM0056
Wiring for 5/6 pin, 6/16 ampere plug point with 4.0 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switchincluding earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
CM0057
Wiring for 5/6 pin, 6/16 ampere plug point with 4.0 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switchincluding earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
CM0058
Wiring for 5/6 pin, 6/16 ampere plug point with 4.0 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switchincluding earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
Labour and Material Coefficients (Electrical)- 2013 Page 32
Department of Engineering Services, MoWHS
Coefficient for per m of CM0090
Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4071 PVC insulated Single Core Copper conductor 1.1KVG - 1.5 sq.mm 2.02 m MT7000 PVC mini-trunking - 32x12.5 mm 1 m MT7002 Changeable internal angle 0.3 each
MT7002 Changeable external angle 0.21 eachMT7003 Changeable flat angle 0.32 eachMT7001 End caps 0.03 each
Coefficient for per m of CM0091
Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4074 PVC insulated Single Core Copper conductor 1.1KVG - 4.0 sq.mm 2.02 m MT7005 PVC mini-trunking - 32x16 mm 1 m MT7002 Changeable internal angle 0.3 each
MT7002 Changeable external angle 0.21 eachMT7003 Changeable flat angle 0.32 eachMT7001 End caps 0.03 each
CM0100
Coefficient for per m of CM0100
Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4073 PVC insulated Single Core Copper conductor 1.1KVG - 2.5 sq.mm 2.02 m
MT7005 PVC mini-trunking - 32x16 mm 1 mMT7002 Changeable internal angle 0.3 eachMT7002 Changeable external angle 0.21 eachMT7003 Changeable flat angle 0.32 eachMT7001 End caps 0.03 each
CM0101
Coefficient for per m of CM0101
Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4074 PVC insulated Single Core Copper conductor 1.1KVG - 4.0 sq.mm 2.02 m
MT7005 PVC mini-trunking - 32x16 mm 1 mMT7002 Changeable internal angle 0.3 eachMT7002 Changeable external angle 0.21 eachMT7003 Changeable flat angle 0.32 eachMT7001 End caps 0.03 each
CM0090Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in PVC mini-trunking including connections, painting, testing and commissioning etc. asrequired - 2x1.5 sq.mm
CM0091Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in PVC mini-trunking including connections, painting, testing and commissioning etc. asrequired - 2x4.0 sq.mm
Wiring for lighting circuit with 1.1KV grade, PVC insulated copper conductor cable in PVC mini- trunking including connections, painting, testing and commissioning etc. as required - 2x2.5 sq.mm
Wiring for power circuit with 1.1KV grade, PVC insulated copper conductor cable in PVC mini- trunking including connections, painting, testing and commissioning etc. as required - 2x4.0 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 33
Department of Engineering Services, MoWHS
WM0001
Coefficient for per m of WM0001
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.02 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 1.01 m
WM0002
Coefficient for per m of WM0002
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.02 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 2.02 m
WM0003
Coefficient for per m of WM0003
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.02 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 3.03 m
WM0004
Coefficient for per m of WM0004
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.0062 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 4.04 m
WM0005
Coefficient for per m of WM0005
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.0062 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 5.05 m
WM0006
Coefficient for per m of WM0006
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.0062 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 6.06 m
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 1x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 2x1.5 sq.mm
CHAPTER 3: MS CONDUIT WIRING
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 4x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 3x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 5x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 6x1.5 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 34
Department of Engineering Services, MoWHS
WM0007
Coefficient for per m of WM0007
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.0076 day LB0069 Wireman Gd.2 0.03 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 7.07 m
WM0008
Coefficient for per m of WM0008
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.0076 day LB0069 Wireman Gd.2 0.03 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 8.08 m
WM0009
Coefficient for per m of WM0009
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.02 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 2.02 m
WM0010
Coefficient for per m of WM0010
Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.023 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 3.03 m
WM0011
Coefficient for per m of WM0011
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.0062 day LB0069 Wireman Gd.2 0.025 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 4.04 m
WM0012
Coefficient for per m of WM0012
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.0062 day LB0069 Wireman Gd.2 0.025 day MT4021 PVC insulated & sheathed single core Aluminium conductor, 440V G - 2.5 sq.m 5.05 m
WM0013
Coefficient for per m of WM0013
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0067 Painter Gd.2 0.0076 day LB0069 Wireman Gd.2 0.028 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 6.06 m
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 4x2.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 3x2.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 2x2.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 6x2.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 7x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 8x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 5x2.5 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 35
Department of Engineering Services, MoWHS
WM0014
Coefficient for per m of WM0014
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.02 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 2.02 m
WM0015
Coefficient for per m of WM0015
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.0062 day LB0069 Wireman Gd.2 0.025 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 3.03 m
WM0016
Coefficient for per m of WM0016
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.0076 day LB0069 Wireman Gd.2 0.03 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 4.04 m
WM0017
Coefficient for per m of WM0017
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.0076 day LB0069 Wireman Gd.2 0.03 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 5.05 m
WM0018
Coefficient for per m of WM0018
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.02 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 2.02 m
WM0019
Coefficient for per m of WM0019
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.0076 day LB0069 Wireman Gd.2 0.03 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 3.0302 m
WM0020
Coefficient for per m of WM0020
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.0076 day LB0069 Wireman Gd.2 0.03 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 4.04 m
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 2x4 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 3x4 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 4x6 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 4x4 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 5x4 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 2x6 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 3x6 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 36
Department of Engineering Services, MoWHS
WM0040
Coefficient for per m of WM0040
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 1.01 m
WM0041
Coefficient for per m of WM0041
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m
WM0042
Coefficient for per m of WM0042
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 3.03 m
WM0043
Coefficient for per m of WM0043
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.04 m
WM0044
Coefficient for per m of WM0044
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 5.05 m
WM0045
Coefficient for per m of WM0045
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.06 m
WM0046
Coefficient for per m of WM0046
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 7.07 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 1x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 2x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 3x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 4x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 5x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 6x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 7x1 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 37
Department of Engineering Services, MoWHS
WM0047
Coefficient for per m of WM0047
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 8.08 m
WM0048
Coefficient for per m of WM0048
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 9.09 m
WM0049
Coefficient for per m of WM0049
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m
WM0050
Coefficient for per m of WM0050
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 3.03 m
WM0051
Coefficient for per m of WM0051
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.04 m
WM0052
Coefficient for per m of WM0052
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 5.05 m
WM0053
Coefficient for per m of WM0053
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.06 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 8x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 9x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 2x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 3x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 4x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 5x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 6x1.5 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 38
Department of Engineering Services, MoWHS
WM0054
Coefficient for per m of WM0054
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 7.07 m
WM0055
Coefficient for per m of WM0055
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 8.08 m
WM0056
Coefficient for per m of WM0056
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m
WM0057
Coefficient for per m of WM0057
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 3.03 m
WM0058
Coefficient for per m of WM0058
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.04 m
WM0059
Coefficient for per m of WM0059
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 5.05 m
WM0060
Coefficient for per m of WM0060
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 6.06 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 8x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 2x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 3x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 4x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 7x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 5x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 6x2 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 39
Department of Engineering Services, MoWHS
WM0061
Coefficient for per m of WM0061
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m
WM0062
Coefficient for per m of WM0062
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 3.03 m
WM0063
Coefficient for per m of WM0063
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.04 m
WM0064
Coefficient for per m of WM0064
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 5.05 m
WM0065
Coefficient for per m of WM0065
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 6.06 m
WM0066
Coefficient for per m of WM0066
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 2x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 3x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 4x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 5x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 6x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 2x4 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 40
Department of Engineering Services, MoWHS
WM0067
Coefficient for per m of WM0067
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 3.03 m
WM0068
Coefficient for per m of WM0068
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.04 m
WM0069
Coefficient for per m of WM0069
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 5.05 m
WM0070
Coefficient for per m of WM0070
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m
WM0071
Coefficient for per m of WM0071
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 3.0302 m
WM0072
Coefficient for per m of WM0072
Code Description Quant Units LB0056 Wireman Gd.1 0.0338 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.0338 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 3x4 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 4x4 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 5x4 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 2x6 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 3x6 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 4x6 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 41
Department of Engineering Services, MoWHS
WM0095
Coefficient for per point of WM0095
Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
WM0096
Coefficient for per point of WM0096
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
WM0097
Coefficient for per point of WM0097
Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 1 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - Short Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - Medium Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - Long Point
Labour and Material Coefficients (Electrical)- 2013 Page 42
Department of Engineering Services, MoWHS
WM0105
Coefficient for per point of WM0105
Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
WM0106
Coefficient for per point of WM0106
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
WM0107
Coefficient for per point of WM0107
Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 1 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - Medium Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - Short Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - Long Point
Labour and Material Coefficients (Electrical)- 2013 Page 43
Department of Engineering Services, MoWHS
WM0115
Coefficient for per point of WM0115
Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each
WM0116
Coefficient for per point of WM0116
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each
WM0117
Coefficient for per point of WM0117
Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 1 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and comissioning etc. as required- Short Point
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required -Long Point
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
Labour and Material Coefficients (Electrical)- 2013 Page 44
Department of Engineering Services, MoWHS
Coefficient for per point of WM0125
Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WM0126
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WM0127
Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 1 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each
WM0126
WM0125
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
WM0127
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch
Labour and Material Coefficients (Electrical)- 2013 Page 45
Department of Engineering Services, MoWHS
Coefficient for per point of WM0135
Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4809 M.S Coduit - M.S Saddle 4 each MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WM0136
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WM0137
Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 1 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m
switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch
WM0135
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
WM0137
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switchincluding earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WM0136
Labour and Material Coefficients (Electrical)- 2013 Page 46
Department of Engineering Services, MoWHS
MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WM0145
Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4809 M.S Coduit - M.S Saddle 4 each MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WM0146
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WM0147
Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
WM0145
WM0147
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WM0146
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch
Labour and Material Coefficients (Electrical)- 2013 Page 47
Department of Engineering Services, MoWHS
LB0069 Wireman Gd.2 1 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WM0155
Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WM0156
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
WM0155
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WM0156
Labour and Material Coefficients (Electrical)- 2013 Page 48
Department of Engineering Services, MoWHS
Coefficient for per point of WM0157
Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 1 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WM0165
Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WM0166
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point WM0157
Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Short Point
WM0165
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including
Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WM0166
Labour and Material Coefficients (Electrical)- 2013 Page 49
Department of Engineering Services, MoWHS
Coefficient for per point of WM0167
Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 1 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m
MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WM0175
Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WM0176
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
and commissioning etc. as required - Long Point WM0167
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Short Point
WM0175
Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Medium Point
WM0176
Labour and Material Coefficients (Electrical)- 2013 Page 50
Department of Engineering Services, MoWHS
Coefficient for per point of WM0177
Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 1 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per m of WM0185
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.064 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0824 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each
Coefficient for per m of WM0186
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.064 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0824 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each
etc. as required - Long Point WM0177
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 2x1 sq.mm
WM0185
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 2x1.5 sq.mm
WM0186
Labour and Material Coefficients (Electrical)- 2013 Page 51
Department of Engineering Services, MoWHS
Coefficient for per m of WM0187
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.0704 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0906 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each
WM0195
Coefficient for per m of WM0195
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.064 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0824 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each
WM0196
Coefficient for per m of WM0196
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.064 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0824 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each
WM0205
Coefficient for per m of WM0205
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.0704 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0906 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m
required - 2x4 sq.mm WM0187
Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 2x2 sq.mm
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as
Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 2x2.5 sq.mm
Wiring for power circuit with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting,testing and commissioning etc. as required - 2x4 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 52
Department of Engineering Services, MoWHS
MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each
WM0210
Coefficient for per m of WM0210
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.0704 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0906 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m MT4802 M.S Coduit - 25mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each
WM0211
Coefficient for per m of WM0211
Code Description Quant Units LB0051 Mason Gd.2 0.0286 day LB0056 Wireman Gd.1 0.0754 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.097 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m MT4803 M.S Coduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each
WM0212
Coefficient for per m of WM0212
Code Description Quant Units LB0051 Mason Gd.2 0.0286 day LB0056 Wireman Gd.1 0.0754 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.097 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m MT4803 M.S Coduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each
WM0213
Coefficient for per m of WM0213
Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.0874 day
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 2x6 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 2x10 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 2x16 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 4x6 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 53
Department of Engineering Services, MoWHS
LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.01108 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m MT4803 M.S Coduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each
WM0214
Coefficient for per m of WM0214
Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.0874 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.01108 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 4.04 m MT4804 M.S Coduit - 40mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each
WM0215
Coefficient for per m of WM0215
Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.0874 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.01108 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4.04 m MT4805 M.S Coduit - 50mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each
Coefficient for per point of WM0230
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 4x10 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 4x16 sq.mm
commissioning etc. as required - Short Point WM0230
Labour and Material Coefficients (Electrical)- 2013 Page 54
Department of Engineering Services, MoWHS
Coefficient for per point of WM0231
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WM0232
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WM0240
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - Long Point
WM0232
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - Medium Point
WM0231
commissioning etc. as required - Short Point WM0240
Labour and Material Coefficients (Electrical)- 2013 Page 55
Department of Engineering Services, MoWHS
Coefficient for per point of WM0241
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WM0242
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WM0250
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - Long Point
WM0242
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - Medium Point
WM0241
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
WM0250
Labour and Material Coefficients (Electrical)- 2013 Page 56
Department of Engineering Services, MoWHS
MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WM0251
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WM0252
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WM0260
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
WM0260
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WM0251
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
WM0252
Labour and Material Coefficients (Electrical)- 2013 Page 57
Department of Engineering Services, MoWHS
MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WM0261
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WM0262
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WM0270
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
WM0270
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
WM0262
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WM0261
Labour and Material Coefficients (Electrical)- 2013 Page 58
Department of Engineering Services, MoWHS
MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4809 M.S Coduit - M.S Saddle 4 each MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WM0271
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WM0272
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WM0271
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
WM0272
Labour and Material Coefficients (Electrical)- 2013 Page 59
Department of Engineering Services, MoWHS
Coefficient for per point of WM0280
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4809 M.S Coduit - M.S Saddle 4 each MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WM0281
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WM0282
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch
WM0280
WM0281
WM0282
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
Labour and Material Coefficients (Electrical)- 2013 Page 60
Department of Engineering Services, MoWHS
Coefficient for per point of WM0290
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WM0291
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WM0292
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3 pin, 16 ampere socket outlet and
switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3 pin, 16 ampere socket outlet and
WM0290
WM0291
WM0292
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
Labour and Material Coefficients (Electrical)- 2013 Page 61
Department of Engineering Services, MoWHS
Coefficient for per point of WM0300
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WM0301
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WM0302
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Short Point
WM0300
Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WM0301
Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Long Point
WM0302
Labour and Material Coefficients (Electrical)- 2013 Page 62
Department of Engineering Services, MoWHS
Coefficient for per point of WM0310
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WM0311
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Short Point
WM0310
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Medium Point
WM0311
Labour and Material Coefficients (Electrical)- 2013 Page 63
Department of Engineering Services, MoWHS
Coefficient for per point of WM0312
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per m of WM0320
Code Description Quant Units LB0051 Mason Gd.2 0.08 day LB0056 Wireman Gd.1 0.064 day LB0069 Wireman Gd.2 0.144 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each
Coefficient for per m of WM0321
Code Description Quant Units LB0051 Mason Gd.2 0.08 day LB0056 Wireman Gd.1 0.064 day LB0069 Wireman Gd.2 0.144 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each
Coefficient for per m of WM0322
Code Description Quant Units LB0051 Mason Gd.2 0.088 day LB0056 Wireman Gd.1 0.0704 day LB0069 Wireman Gd.2 0.1584 day
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning as required - 2x1 sq.mm
WM0320
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Long Point
WM0312
required - 2x1.5 sq.mm WM0321
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning as required - 2x4 sq.mm
WM0322
Labour and Material Coefficients (Electrical)- 2013 Page 64
Department of Engineering Services, MoWHS
MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each
WM0330
Coefficient for per m of WM0330
Code Description Quant Units LB0051 Mason Gd.2 0.08 day LB0056 Wireman Gd.1 0.064 day LB0069 Wireman Gd.2 0.144 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each
WM0331
Coefficient for per m of WM0331
Code Description Quant Units LB0051 Mason Gd.2 0.08 day LB0056 Wireman Gd.1 0.064 day LB0069 Wireman Gd.2 0.144 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each
WM0340
Coefficient for per m of WM0340
Code Description Quant Units LB0051 Mason Gd.2 0.088 day LB0056 Wireman Gd.1 0.0704 day LB0069 Wireman Gd.2 0.1584 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each
WM0350
Coefficient for per m of WM0350
Code Description Quant Units LB0051 Mason Gd.2 0.088 day LB0056 Wireman Gd.1 0.0704 day LB0069 Wireman Gd.2 0.1584 day
Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - 2x2 sq.mm
Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - 2x2.5 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required- 2x6 sq.mm
Wiring for power circuit with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 65
Department of Engineering Services, MoWHS
MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m MT4802 M.S Coduit - 25mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each
WM0351
Coefficient for per m of WM0351
Code Description Quant Units LB0051 Mason Gd.2 0.0942 day LB0056 Wireman Gd.1 0.0754 day LB0069 Wireman Gd.2 0.1694 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m MT4803 M.S Coduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each
WM0352
Coefficient for per m of WM0352
Code Description Quant Units LB0051 Mason Gd.2 0.0942 day LB0056 Wireman Gd.1 0.0754 day LB0069 Wireman Gd.2 0.1694 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m MT4803 M.S Coduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each
WM0353
Coefficient for per m of WM0353
Code Description Quant Units LB0051 Mason Gd.2 0.1008 day LB0056 Wireman Gd.1 0.0806 day LB0069 Wireman Gd.2 0.1812 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m MT4803 M.S Coduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required- 2x10 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - 4x6 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required- 2x16 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 66
Department of Engineering Services, MoWHS
WM0354
Coefficient for per m of WM0354
Code Description Quant Units LB0051 Mason Gd.2 0.1078 day LB0056 Wireman Gd.1 0.0862 day LB0069 Wireman Gd.2 0.01938 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 4.04 m MT4804 M.S Coduit - 40mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each
WM0355
Coefficient for per m of WM0355
Code Description Quant Units LB0051 Mason Gd.2 0.1078 day LB0056 Wireman Gd.1 0.0862 day LB0069 Wireman Gd.2 0.01938 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4.04 m MT4805 M.S Coduit - 50mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each
WC0001
Coefficient for per m of WC0001
Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0069 Wireman Gd.2 0.024 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 1.01 m
WC0002
Coefficient for per m of WC0002
Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0069 Wireman Gd.2 0.024 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 2.02 m
WC0003
Coefficient for per m of WC0003
Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0069 Wireman Gd.2 0.024 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 3.03 m
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - 4x16 sq.mm
CHAPTER 4: PVC CONDUIT WIRING
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 1x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 2x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 3x1.5 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - 4x10 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 67
Department of Engineering Services, MoWHS
WC0004
Coefficient for per m of WC0004
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 4.04 m
WC0005
Coefficient for per m of WC0005
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 5.05 m
WC0006
Coefficient for per m of WC0006
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 6.06 m
WC0007
Coefficient for per m of WC0007
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 7.07 m
WC0008
Coefficient for per m of WC0008
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 8.08 m
WC0009
Coefficient for per m of WC0009
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 2.02 m
WC0010
Coefficient for per m of WC0010
Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 3.03 m
WC0011
Coefficient for per m of WC0011
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 4.04 m
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 7x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 5x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 6x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 8x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 2x2.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 4x1.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 3x2.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 4x2.5 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 68
Department of Engineering Services, MoWHS
WC0012
Coefficient for per m of WC0012
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 5.05 m
WC0013
Coefficient for per m of WC0013
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 6.06 m
WC0014
Coefficient for per m of WC0014
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 2.02 m
WC0015
Coefficient for per m of WC0015
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 3.03 m
WC0016
Coefficient for per m of WC0016
Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.027 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 4.04 m
WC0017
Coefficient for per m of WC0017
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 5.05 m
WC0018
Coefficient for per m of WC0018
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 2.02 m
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 2x4 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 3x4 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 4x4 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 5x4 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 5x2.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 6x2.5 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 2x6 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 69
Department of Engineering Services, MoWHS
WC0019
Coefficient for per m of WC0019
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 3.0302 m
WC0020
Coefficient for per m of WC0020
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 4.04 m
WC0040
Coefficient for per m of WC0040
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 1.01 m
WC0041
Coefficient for per m of WC0041
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m
WC0042
Coefficient for per m of WC0042
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 3.03 m
WC0043
Coefficient for per m of WC0043
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.04 m
WC0044
Coefficient for per m of WC0044
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 5.05 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 2x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 3x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 4x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 5x1 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 3x6 sq.mm
Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 4x6 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 1x1 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 70
Department of Engineering Services, MoWHS
WC0045
Coefficient for per m of WC0045
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.06 m
WC0046
Coefficient for per m of WC0046
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 7.07 m
WC0047
Coefficient for per m of WC0047
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 8.08 m
WC0048
Coefficient for per m of WC0048
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 9.09 m
WC0049
Coefficient for per m of WC0049
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m
WC0050
Coefficient for per m of WC0050
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 3.03 m
WC0051
Coefficient for per m of WC0051
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.04 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 4x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 6x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 7x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 8x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 9x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 2x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 3x1.5 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 71
Department of Engineering Services, MoWHS
WC0052
Coefficient for per m of WC0052
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 5.05 m
WC0053
Coefficient for per m of WC0053
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.06 m
WC0054
Coefficient for per m of WC0054
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 7.07 m
WC0055
Coefficient for per m of WC0055
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 8.08 m
WC0056
Coefficient for per m of WC0056
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m
WC0057
Coefficient for per m of WC0057
Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 3.03 m
WC0058
Coefficient for per m of WC0058
Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0069 Wireman Gd.2 0.024 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.04 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 7x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 6x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 5x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 2x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 3x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 8x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 4x2 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 72
Department of Engineering Services, MoWHS
WC0059
Coefficient for per m of WC0059
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 5.05 m
WC0060
Coefficient for per m of WC0060
Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0069 Wireman Gd.2 0.026 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 6.06 m
WC0061
Coefficient for per m of WC0061
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m
WC0062
Coefficient for per m of WC0062
Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 3.03 m
WC0063
Coefficient for per m of WC0063
Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0069 Wireman Gd.2 0.024 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.04 m
WC0064
Coefficient for per m of WC0064
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 5.05 m
WC0065
Coefficient for per m of WC0065
Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0069 Wireman Gd.2 0.026 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 6.06 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 5x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 4x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 5x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 6x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 6x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 2x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 3x2.5 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 73
Department of Engineering Services, MoWHS
WC0066
Coefficient for per m of WC0066
Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m
WC0067
Coefficient for per m of WC0067
Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0069 Wireman Gd.2 0.024 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 3.03 m
WC0068
Coefficient for per m of WC0068
Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0069 Wireman Gd.2 0.026 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.04 m
WC0069
Coefficient for per m of WC0069
Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.027 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 5.05 m
WC0070
Coefficient for per m of WC0070
Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0069 Wireman Gd.2 0.024 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m
WC0071
Coefficient for per m of WC0071
Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0069 Wireman Gd.2 0.026 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 3.0302 m
WC0072
Coefficient for per m of WC0072
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 5x4 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 4x4 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 3x4 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 2x6 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 3x6 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 4x6 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 2x4 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 74
Department of Engineering Services, MoWHS
WC0095
Coefficient for per m of WC0095
Code Description Quant Units LB0051 Mason Gd.2 0.01 day LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 1.01 m
WC0096
Coefficient for per m of WC0096
Code Description Quant Units LB0051 Mason Gd.2 0.01 day LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m
WC0097
Coefficient for per m of WC0097
Code Description Quant Units LB0051 Mason Gd.2 0.01 day LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 3.03 m
WC0098
Coefficient for per m of WC0098
Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.04 m
WC0099
Coefficient for per m of WC0099
Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 5.05 m
WC0100
Coefficient for per m of WC0100
Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.06 m
WC0101
Coefficient for per m of WC0101
Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 7.07 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 1x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 2x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 5x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 6x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 7x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 3x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 4x1 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 75
Department of Engineering Services, MoWHS
WC0102
Coefficient for per m of WC0102
Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 8.08 m
WC0103
Coefficient for per m of WC0103
Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 9.09 m
WC0104
Coefficient for per m of WC0104
Code Description Quant Units LB0051 Mason Gd.2 0.01 day LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m
WC0105
Coefficient for per m of WC0105
Code Description Quant Units LB0051 Mason Gd.2 0.01 day LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 3.03 m
WC0106
Coefficient for per m of WC0106
Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.04 m
WC0107
Coefficient for per m of WC0107
Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 5.05 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 9x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 2x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 5x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 8x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 3x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 4x1.5 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 76
Department of Engineering Services, MoWHS
WC0108
Coefficient for per m of WC0108
Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.06 m
WC0109
Coefficient for per m of WC0109
Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 7.07 m
WC0110
Coefficient for per m of WC0110
Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 8.08 m
WC0111
Coefficient for per m of WC0111
Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m
WC0112
Coefficient for per m of WC0112
Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 3.03 m
WC0113
Coefficient for per m of WC0113
Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.04 m
WC0114
Coefficient for per m of WC0114
Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 5.05 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 6x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 2x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 3x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 4x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 5x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 7x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 8x1.5 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 77
Department of Engineering Services, MoWHS
WC0115
Coefficient for per m of WC0115
Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 6.06 m
WC0116
Coefficient for per m of WC0116
Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m
WC0117
Coefficient for per m of WC0117
Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 3.03 m
WC0118
Coefficient for per m of WC0118
Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.04 m
WC0119
Coefficient for per m of WC0119
Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 5.05 m
WC0120
Coefficient for per m of WC0120
Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 6.06 m
WC0121
Coefficient for per m of WC0121
Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 2x4 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 4x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 5x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 3x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 6x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 2x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 6x2.5 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 78
Department of Engineering Services, MoWHS
WC0122
Coefficient for per m of WC0122
Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.044 day LB0069 Wireman Gd.2 0.044 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 3.03 m
WC0123
Coefficient for per m of WC0123
Code Description Quant Units LB0051 Mason Gd.2 0.016 day LB0056 Wireman Gd.1 0.046 day LB0069 Wireman Gd.2 0.046 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.04 m
WC0124
Coefficient for per m of WC0124
Code Description Quant Units LB0051 Mason Gd.2 0.016 day LB0056 Wireman Gd.1 0.048 day LB0069 Wireman Gd.2 0.048 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 5.05 m
WC0125
Coefficient for per m of WC0125
Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m
WC0126
Coefficient for per m of WC0126
Code Description Quant Units LB0051 Mason Gd.2 0.016 day LB0056 Wireman Gd.1 0.044 day LB0069 Wireman Gd.2 0.044 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 3.0302 m
WC0127
Coefficient for per m of WC0127
Code Description Quant Units LB0051 Mason Gd.2 0.016 day LB0056 Wireman Gd.1 0.048 day LB0069 Wireman Gd.2 0.048 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 3x6 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 4x6 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 3x4 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 4x4 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 5x4 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 2x6 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 79
Department of Engineering Services, MoWHS
WC0150
Coefficient for per point of WC0150
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
WC0151
Coefficient for per point of WC0151
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
WC0152
Coefficient for per point of WC0152
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m MT4840 PVC Conduit - 20 mm,18SWG 6.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - Long Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - Medium Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - Short Point
Labour and Material Coefficients (Electrical)- 2013 Page 80
Department of Engineering Services, MoWHS
WC0160
Coefficient for per point of WC0160
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
WC0161
Coefficient for per point of WC0161
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
WC0162
Coefficient for per point of WC0162
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m MT4840 PVC Conduit - 20 mm,18SWG 6.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - Short Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - Long Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - Medium Point
Labour and Material Coefficients (Electrical)- 2013 Page 81
Department of Engineering Services, MoWHS
Coefficient for per point of WC0170
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4862 PVC Boxes - 3 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WC0171
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT4862 PVC Boxes - 3 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WC0172
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4840 PVC Conduit - 20 mm,18SWG 6.4 m MT4862 PVC Boxes - 3 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each
earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including
earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including
WC0171
WC0172
WC0170
earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
Labour and Material Coefficients (Electrical)- 2013 Page 82
Department of Engineering Services, MoWHS
Coefficient for per point of WC0180
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4862 PVC Boxes - 3 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WC0181
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT4862 PVC Boxes - 3 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WC0182
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4840 PVC Conduit - 20 mm,18SWG 6.4 m MT4862 PVC Boxes - 3 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each
WC0181
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including
earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WC0182
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
WC0180
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including
earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
Labour and Material Coefficients (Electrical)- 2013 Page 83
Department of Engineering Services, MoWHS
MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WC0190
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4863 PVC Boxes - 4 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0191
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT4863 PVC Boxes - 4 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0192
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4840 PVC Conduit - 20 mm,18SWG 6.4 m MT4863 PVC Boxes - 4 Module 1 each
earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including WC0190
WC0191
earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including WC0192
Labour and Material Coefficients (Electrical)- 2013 Page 84
Department of Engineering Services, MoWHS
MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0200
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4863 PVC Boxes - 4 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0201
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT4863 PVC Boxes - 4 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0202
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m
earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point WC0200
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including WC0201
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
WC0202
Labour and Material Coefficients (Electrical)- 2013 Page 85
Department of Engineering Services, MoWHS
MT4809 M.S Coduit - M.S Saddle 15 each MT4840 PVC Conduit - 20 mm,18SWG 6.4 m MT4863 PVC Boxes - 4 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0210
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4863 PVC Boxes - 4 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0211
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT4863 PVC Boxes - 4 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0212
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day
earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point WC0210
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including
earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point WC0211
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
WC0212
Labour and Material Coefficients (Electrical)- 2013 Page 86
Department of Engineering Services, MoWHS
LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4840 PVC Conduit - 20 mm,18SWG 6.4 m MT4863 PVC Boxes - 4 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0220
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4860 PVC Boxes - 1 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WC0221
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m MT4809 M.S Coduit - M.S Saddle 9 each MT4860 PVC Boxes - 1 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WC0222
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day
Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with 2 way 6 ampere switch including earthing third pin, connections, painting,testing and commissioning etc. as required - Short Point
WC0220
Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WC0221
Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Long Point
WC0222
Labour and Material Coefficients (Electrical)- 2013 Page 87
Department of Engineering Services, MoWHS
MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m MT4809 M.S Coduit - M.S Saddle 15 each MT4860 PVC Boxes - 1 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT4840 PVC Conduit - 20 mm,18SWG 6.4 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WC0230
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4860 PVC Boxes - 1 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WC0231
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m MT4809 M.S Coduit - M.S Saddle 9 each MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT4860 PVC Boxes - 1 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WC0232
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m MT4809 M.S Coduit - M.S Saddle 15 each MT4840 PVC Conduit - 20 mm,18SWG 6.4 m
commissioning etc. as required - Short Point WC0230
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with 2 way 6 ampere switch including connections, painting, testing andcommissioning etc. as required - Medium Point
WC0231
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with 2 way 6 ampere switch including connections, painting, testing and
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Long Point
WC0232
Labour and Material Coefficients (Electrical)- 2013 Page 88
Department of Engineering Services, MoWHS
MT4860 PVC Boxes - 1 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per m of WC0240
Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m MT4840 PVC Conduit - 20 mm,18SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each
Coefficient for per m of WC0241
Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m MT4840 PVC Conduit - 20 mm,18SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each
Coefficient for per m of WC0242
Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4840 PVC Conduit - 20 mm,18SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each
Coefficient for per m of WC0250
Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m MT4840 PVC Conduit - 20 mm,18SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each
required - 2x1 sq.mm WC0240
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as
Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required- 2x2 sq.mm
WC0250
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 2x1.5 sq.mm
WC0241
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm
WC0242
Labour and Material Coefficients (Electrical)- 2013 Page 89
Department of Engineering Services, MoWHS
WC0251
Coefficient for per m of WC0251
Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m MT4840 PVC Conduit - 20 mm,18SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each
WC0260
Coefficient for per m of WC0260
Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4840 PVC Conduit - 20 mm,18SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each
WC0270
Coefficient for per m of WC0270
Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m MT4841 PVC Conduit - 25 mm,16SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each
WC0271
Coefficient for per m of WC0271
Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m MT4842 PVC Conduit - 32 mm,14SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each
Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 2x2.5 sq.mm
Wiring for power circuit with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 2x6 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 2x10 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 90
Department of Engineering Services, MoWHS
WC0272
Coefficient for per m of WC0272
Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m MT4842 PVC Conduit - 32 mm,14SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each
WC0273
Coefficient for per m of WC0273
Code Description Quant Units LB0051 Mason Gd.2 0.0242 day LB0056 Wireman Gd.1 0.0534 day LB0067 Painter Gd.2 0.0266 day LB0069 Wireman Gd.2 0.0776 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m MT4842 PVC Conduit - 32 mm,14SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each
WC0274
Coefficient for per m of WC0274
Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.067 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 4.04 m MT4843 PVC Conduit - 40 mm,14SWG 1 m MT4872 Inspection bend for conduit 0.2 each MT4874 PVC sleev 35mm 4.08 each
WC0275
Coefficient for per m of WC0275
Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.067 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4.04 m MT4844 PVC Conduit - 50 mm,14SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 4x16 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 2x16 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 4x6 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 4x10 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 91
Department of Engineering Services, MoWHS
Coefficient for per point of WC0290
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe - 20mm 1.5 m MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WC0291
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4850 HDPE pipe - 20mm 3.75 m MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WC0292
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4850 HDPE pipe - 20mm 6.4 m MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - Long Point
WC0291
WC0292
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - Medium Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - Short Point
WC0290
Labour and Material Coefficients (Electrical)- 2013 Page 92
Department of Engineering Services, MoWHS
Coefficient for per point of WC0300
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe - 20mm 1.5 m MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WC0301
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4850 HDPE pipe - 20mm 3.75 m MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WC0302
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4850 HDPE pipe - 20mm 6.4 m MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
commissioning etc. as required - Long Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and
commissioning etc. as required - Short Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - Medium Point
WC0301
WC0302
WC0300
Labour and Material Coefficients (Electrical)- 2013 Page 93
Department of Engineering Services, MoWHS
Coefficient for per point of WC0310
Code Description Quant Units LB0051 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe - 20mm 1.5 m
MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 2 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WC0311
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each mt4850 HDPE pipe - 20mm 3.75 m MT4870 PVC Socket 2 each
MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WC0312
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4850 HDPE pipe - 20mm 6.4 m MT4870 PVC Socket 3 each
MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each
earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including
earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including
WC0311
WC0312
WC0310
Labour and Material Coefficients (Electrical)- 2013 Page 94
Department of Engineering Services, MoWHS
MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WC0320
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe - 20mm 1.5 m
MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WC0321
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4850 HDPE pipe - 20mm 3.75 m MT4870 PVC Socket 2 each
MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WC0322
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4850 HDPE pipe - 20mm 6.4 m MT4870 PVC Socket 3 each
MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3/5 pin, 6 ampere socket outlet and switch
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
WC0321
WC0322
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3/5 pin, 6 ampere socket outlet and switch
WC0320
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
Labour and Material Coefficients (Electrical)- 2013 Page 95
Department of Engineering Services, MoWHS
MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WC0330
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe -20mm 1.5 m
MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0331
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4850 HDPE pipe - 20mm 3.75 m MT4870 PVC Socket 2 each
MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0332
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4850 HDPE pipe - 20mm 6.4 m MT4870 PVC Socket 3 each
MT4871 Junction box, 1 or 2 way for conduit 1 each
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3 pin, 6/16 ampere socket outlet and switch
WC0331
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
WC0332
WC0330
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3 pin, 6/16 ampere socket outlet and switch
Labour and Material Coefficients (Electrical)- 2013 Page 96
Department of Engineering Services, MoWHS
MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0340
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe - 20mm 1.5 m
MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0341
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4850 HDPE pipe - 20mm 3.75 m MT4870 PVC Socket 2 each
MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0342
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4850 HDPE pipe - 20mm 6.4 m
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
WC0342
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
WC0340
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WC0341
Labour and Material Coefficients (Electrical)- 2013 Page 97
Department of Engineering Services, MoWHS
MT4870 PVC Socket 3 eachMT4871 Junction box, 1 or 2 way for conduit 1 each
MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0350
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe - 20mm 1.5 m
MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0351
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4850 HDPE pipe - 20mm 3.75 m MT4870 PVC Socket 2 each
MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0352
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WC0351
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
WC0352
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
WC0350
Labour and Material Coefficients (Electrical)- 2013 Page 98
Department of Engineering Services, MoWHS
MT4809 M.S Coduit - M.S Saddle 15 each MT4850 HDPE pipe - 20mm 6.4 m MT4870 PVC Socket 3 each
MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WC0360
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe - 20mm 1.5 m MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WC0361
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m MT4809 M.S Coduit - M.S Saddle 9 each MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT4850 HDPE pipe - 20mm 3.75 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WC0362
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m
Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Short Point
WC0360
Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WC0361
Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Long Point
WC0362
Labour and Material Coefficients (Electrical)- 2013 Page 99
Department of Engineering Services, MoWHS
MT4809 M.S Coduit - M.S Saddle 15 each MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT4850 HDPE pipe - 20mm 6.4 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WC0370
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe - 20mm 1.5 m MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WC0371
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m MT4809 M.S Coduit - M.S Saddle 9 each MT4850 HDPE pipe - 20mm 3.75 m MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WC0372
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m MT4809 M.S Coduit - M.S Saddle 15 each
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Short Point
WC0370
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Medium Point
WC0371
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Long Point
WC0372
Labour and Material Coefficients (Electrical)- 2013 Page 100
Department of Engineering Services, MoWHS
MT4850 HDPE pipe - 20mm 6.4 m MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per m of WC0380
Code Description Quant Units LB0051 Mason Gd.2 0.0784 day LB0056 Wireman Gd.1 0.0628 day LB0069 Wireman Gd.2 0.1412 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4850 HDPE pipe - 20mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each
Coefficient for per m of WC0381
Code Description Quant Units LB0051 Mason Gd.2 0.0784 day LB0056 Wireman Gd.1 0.0628 day LB0069 Wireman Gd.2 0.1412 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4850 HDPE pipe - 20mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each
Coefficient for per m of WC0382
Code Description Quant Units LB0051 Mason Gd.2 0.0864 day LB0056 Wireman Gd.1 0.069 day LB0069 Wireman Gd.2 0.1552 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4850 HDPE pipe - 20mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x1 sq.mm
WC0380
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x1.5 sq.mm
WC0381
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm
WC0382
Labour and Material Coefficients (Electrical)- 2013 Page 101
Department of Engineering Services, MoWHS
WC0390
Coefficient for per m of WC0390
Code Description Quant Units LB0051 Mason Gd.2 0.0784 day LB0056 Wireman Gd.1 0.0628 day LB0069 Wireman Gd.2 0.1412 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4850 HDPE pipe - 20mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each
WC0391
Coefficient for per m of WC0391
Code Description Quant Units LB0051 Mason Gd.2 0.0784 day LB0056 Wireman Gd.1 0.0628 day LB0069 Wireman Gd.2 0.1412 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4850 HDPE pipe - 20mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each
WC0400
Coefficient for per m of WC0400
Code Description Quant Units LB0051 Mason Gd.2 0.0864 day LB0056 Wireman Gd.1 0.069 day LB0069 Wireman Gd.2 0.1552 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4850 HDPE pipe - 20mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each
WC0410
Coefficient for per m of WC0410
Code Description Quant Units LB0051 Mason Gd.2 0.0864 day LB0056 Wireman Gd.1 0.069 day LB0069 Wireman Gd.2 0.1552 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4851 HDPE pipe - 25mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each
Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x2 sq.mm
Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x2.5 sq.mm
Wiring for power circuit with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x6 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 102
Department of Engineering Services, MoWHS
WC0411
Coefficient for per m of WC0411
Code Description Quant Units LB0051 Mason Gd.2 0.0924 day LB0056 Wireman Gd.1 0.074 day LB0069 Wireman Gd.2 0.166 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4852 HDPE pipe - 32mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each
WC0412
Coefficient for per m of WC0412
Code Description Quant Units LB0051 Mason Gd.2 0.0924 day LB0056 Wireman Gd.1 0.074 day LB0069 Wireman Gd.2 0.166 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4852 HDPE pipe - 32 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each
WC0413
Coefficient for per m of WC0413
Code Description Quant Units LB0051 Mason Gd.2 0.0988 day LB0056 Wireman Gd.1 0.079 day LB0069 Wireman Gd.2 0.1776 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4852 HDPE pipe - 32mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each
WC0414
Coefficient for per m of WC0414
Code Description Quant Units LB0051 Mason Gd.2 0.1058 day LB0056 Wireman Gd.1 0.0844 day LB0069 Wireman Gd.2 0.19 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 4.04 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4853 HDPE pipe - 40mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.2 each MT4874 PVC sleev 35mm 4 each
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x10 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x16 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 4x6 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 4x10 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 103
Department of Engineering Services, MoWHS
WC0415
Coefficient for per m of WC0415
Code Description Quant Units LB0051 Mason Gd.2 0.1058 day LB0056 Wireman Gd.1 0.0844 day LB0069 Wireman Gd.2 0.19 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4.04 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4854 HDPE pipe - 50mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each
CHAPTER 5: STAINLESS STEEL CONDUIT WIRING
WS0001
Coefficient for per m of WS0001
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 1.01 m
WS0002
Coefficient for per m of WS0002
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m
WS0003
Coefficient for per m of WS0003
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 3.03 m
WS0004
Coefficient for per m of WS0004
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.04 m
WS0005
Coefficient for per m of WS0005
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 5.05 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 2x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 3x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 4x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 1x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 5x1 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 4x16 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 104
Department of Engineering Services, MoWHS
WS0006
Coefficient for per m of WS0006
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.06 m
WS0007
Coefficient for per m of WS0007
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 7.07 m
WS0008
Coefficient for per m of WS0008
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 8.08 m
WS0009
Coefficient for per m of WS0009
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 9.09 m
WS0010
Coefficient for per m of WS0010
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m
WS0011
Coefficient for per m of WS0011
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 3.03 m
WS0012
Coefficient for per m of WS0012
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.04 m
WS0013
Coefficient for per m of WS0013
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 5.05 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 9x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 8x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 7x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 2x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 6x1 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 3x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 4x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 5x1.5 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 105
Department of Engineering Services, MoWHS
WS0014
Coefficient for per m of WS0014
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.06 m
WS0015
Coefficient for per m of WS0015
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 7.07 m
WS0016
Coefficient for per m of WS0016
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 8.08 m
WS0017
Coefficient for per m of WS0017
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m
WS0018
Coefficient for per m of WS0018
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 3.03 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 6x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 7x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 8x1.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 2x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 3x2 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 106
Department of Engineering Services, MoWHS
WS0019
Coefficient for per m of WS0019
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.04 m
WS0020
Coefficient for per m of WS0020
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 5.05 m
WS0021
Coefficient for per m of WS0021
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 6.06 m
WS0022
Coefficient for per m of WS0022
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m
WS0023
Coefficient for per m of WS0023
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 3.03 m
WS0024
Coefficient for per m of WS0024
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.04 m
WS0025
Coefficient for per m of WS0025
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 5.05 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 5x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 4x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 5x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 6x2 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 2x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 3x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 4x2.5 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 107
Department of Engineering Services, MoWHS
WS0026
Coefficient for per m of WS0026
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 6.06 m
WS0027
Coefficient for per m of WS0027
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m
WS0028
Coefficient for per m of WS0028
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 3.03 m
WS0029
Coefficient for per m of WS0029
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.04 m
WS0030
Coefficient for per m of WS0030
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 5.05 m
WS0031
Coefficient for per m of WS0031
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m
WS0032
Coefficient for per m of WS0032
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 3.0302 m
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 6x2.5 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 2x4 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 3x4 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 4x4 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 5x4 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 2x6 sq.mm
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 3x6 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 108
Department of Engineering Services, MoWHS
WS0033
Coefficient for per m of WS0033
Code Description Quant Units LB0056 Wireman Gd.1 0.0338 day LB0069 Wireman Gd.2 0.0338 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m
Coefficient for per point of WS0055
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WS0056
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WS0057
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m
commissioning etc. as required - Long Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and
commissioning etc. as required - Medium Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and
Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 4x6 sq.mm
Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - Short Point
WS0055
WS0056
WS0057
Labour and Material Coefficients (Electrical)- 2013 Page 109
Department of Engineering Services, MoWHS
MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WS0065
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WS0066
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WS0067
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and
commissioning etc. as required - Medium Point
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and
commissioning etc. as required - Short Point WS0065
Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and WS0066
commissioning etc. as required - Long Point WS0067
Labour and Material Coefficients (Electrical)- 2013 Page 110
Department of Engineering Services, MoWHS
LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WS0075
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WS0076
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each
including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WS0076
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
WS0075
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch
Labour and Material Coefficients (Electrical)- 2013 Page 111
Department of Engineering Services, MoWHS
Coefficient for per point of WS0077
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WS0085
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WS0086
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each
switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and
Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WS0086
WS0077
WS0085
Labour and Material Coefficients (Electrical)- 2013 Page 112
Department of Engineering Services, MoWHS
Coefficient for per point of WS0087
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each
Coefficient for per point of WS0095
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WS0096
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
WS0095
switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
WS0087
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WS0096
Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and
Labour and Material Coefficients (Electrical)- 2013 Page 113
Department of Engineering Services, MoWHS
Coefficient for per point of WS0097
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WS0105
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WS0106
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each
Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
WS0097
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
WS0105
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WS0106
Labour and Material Coefficients (Electrical)- 2013 Page 114
Department of Engineering Services, MoWHS
Coefficient for per point of WS0107
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WS0115
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WS0116
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each
Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
WS0107
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point
WS0115
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WS0116
Labour and Material Coefficients (Electrical)- 2013 Page 115
Department of Engineering Services, MoWHS
Coefficient for per point of WS0117
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each
Coefficient for per point of WS0125
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WS0126
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point
WS0117
Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Short Point
WS0125
Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Medium Point
WS0126
Labour and Material Coefficients (Electrical)- 2013 Page 116
Department of Engineering Services, MoWHS
Coefficient for per point of WS0127
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m
MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WS0135
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WS0136
Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each
Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Long Point
WS0127
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Short Point
WS0135
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Medium Point
WS0136
Labour and Material Coefficients (Electrical)- 2013 Page 117
Department of Engineering Services, MoWHS
MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per point of WS0137
Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per m of WS0145
Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m MT4820 Steel Conduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each
Coefficient for per m of WS0146
Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m MT4820 Steel Conduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each
Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Long Point
WS0137
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 2x1 sq.mm
WS0145
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 2x1.5 sq.mm
WS0146
Labour and Material Coefficients (Electrical)- 2013 Page 118
Department of Engineering Services, MoWHS
Coefficient for per m of WS0147
Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4820 Steel Conduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each
WS0155
Coefficient for per m of WS0155
Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m MT4820 Steel Conduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each
WS0156
Coefficient for per m of WS0156
Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m MT4820 Steel Conduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each
WS0165
Coefficient for per m of WS0165
Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4820 Steel Conduit - 20mm x 1.6mm 1 m
Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm
WS0147
Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 2x2 sq.mm
Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required-2x2.5 sq.mm
Wiring for power circuit with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 119
Department of Engineering Services, MoWHS
MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each
WS0175
Coefficient for per m of WS0175
Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m MT4821 Steel Conduit - 25mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each
WS0176
Coefficient for per m of WS0176
Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m MT4822 Steel Conduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each
WS0177
Coefficient for per m of WS0177
Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m MT4822 Steel Conduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each
WS0178
Coefficient for per m of WS0178
Code Description Quant Units LB0051 Mason Gd.2 0.0242 day LB0056 Wireman Gd.1 0.0534 day
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 2x6 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 2x10 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 2x16 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 4x6 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 120
Department of Engineering Services, MoWHS
LB0067 Painter Gd.2 0.0266 day LB0069 Wireman Gd.2 0.0776 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m MT4822 Steel Conduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each
WS0179
Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.067 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 4.04 m MT4823 Steel Conduit - 40mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each
WS0180
Coefficient for per m of WS0180
Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.067 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4.04 m MT4824 Steel Conduit - 50mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each
CHAPTER 6: RE-WIRING
Coefficient for per point of WR0115
Code Description Quant Units LB0056 Wireman Gd.1 0.17 day LB0069 Wireman Gd.2 0.17 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m
Coefficient for per point of WR0116
Code Description Quant Units LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 4x10 sq.mm
Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 4x16 sq.mm
Rewiring of light, fans, call bell and 2 pin 6 ampere plug point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantling as per site requirement, painting, testing and commissioning etc. as required - Medium Point
WR0116
Coefficient for per m of WS0179
Rewiring of light, fans, call bell and 2 pin 6 ampere plug point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantling as per site requirement, painting, testing and commissioning etc. as required - Short Point
WR0115
Labour and Material Coefficients (Electrical)- 2013 Page 121
Department of Engineering Services, MoWHS
Coefficient for per point of WR0117
Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m
Coefficient for per point of WR0125
Code Description Quant Units LB0056 Wireman Gd.1 0.17 day LB0069 Wireman Gd.2 0.17 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m
Coefficient for per point of WR0126
Code Description Quant Units LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m
Coefficient for per point of WR0127
Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m
Coefficient for per point of WR0135
Code Description Quant Units LB0056 Wireman Gd.1 0.17 day LB0069 Wireman Gd.2 0.17 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m
Coefficient for per point of WR0136
Code Description Quant Units LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m
Rewiring of light, fans, call bell and 2 pin 6 ampere plug point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantling as per site requirement, painting, testing and commissioning etc. as required - Long Point
WR0117
Rewiring of light, fans, call bell and 2 pin 6 ampere plug point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantling as per site requirement, painting, testing and commissioning etc. as required - Short Point
WR0125
Rewiring of light, fans, call bell and 2 pin 6 ampere plug point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantling as per site requirement, painting, testing and commissioning etc. as required - Medium Point
WR0126
Rewiring of light, fans, call bell and 2 pin 6 ampere plug point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantling as per site requirement, painting, testing and commissioning etc. as required - Long Point
WR0127
Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point
WR0135
Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point
WR0136
Labour and Material Coefficients (Electrical)- 2013 Page 122
Department of Engineering Services, MoWHS
Coefficient for per point of WR0137
Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m
Coefficient for per point of WR0145
Code Description Quant Units LB0056 Wireman Gd.1 0.17 day LB0069 Wireman Gd.2 0.17 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m
Coefficient for per point of WR0146
Code Description Quant Units LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m
Coefficient for per point of WR0147
Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m
Coefficient for per point of WR0155
Code Description Quant Units LB0056 Wireman Gd.1 0.17 day LB0069 Wireman Gd.2 0.17 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m
Coefficient for per point of WR0156
Code Description Quant Units LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m
Coefficient for per point of WR0157
Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m
commissioning etc. as required - Long Point WR0157
Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point
WR0137
Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting,testing and commissioning etc. as required - Short Point
WR0145
Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point
WR0146
Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point
WR0147
Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point
WR0155
Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point
WR0156
Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and
Labour and Material Coefficients (Electrical)- 2013 Page 123
Department of Engineering Services, MoWHS
Coefficient for per point of WR0165
Code Description Quant Units LB0056 Wireman Gd.1 0.17 day LB0069 Wireman Gd.2 0.17 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m
Coefficient for per point of WR0166
Code Description Quant Units LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m
Coefficient for per point of WR0167
Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m
Coefficient for per point of WR0175
Code Description Quant Units LB0056 Wireman Gd.1 0.17 day LB0069 Wireman Gd.2 0.17 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m
Coefficient for per point of WR0176
Code Description Quant Units LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m
Coefficient for per point of WR0177
Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m
Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point
WR0176
Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point
WR0177
Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point
WR0167
Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point
WR0175
Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point
WR0165
Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point
WR0166
Labour and Material Coefficients (Electrical)- 2013 Page 124
Department of Engineering Services, MoWHS
Coefficient for per m of WR0185
Code Description Quant Units LB0056 Wireman Gd.1 0.045 day LB0069 Wireman Gd.2 0.045 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m
Coefficient for per m of WR0186
Code Description Quant Units LB0056 Wireman Gd.1 0.045 day LB0069 Wireman Gd.2 0.045 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m
Coefficient for per m of WR0187
Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m
Coefficient for per m of WR0200
Code Description Quant Units LB0056 Wireman Gd.1 0.045 day LB0069 Wireman Gd.2 0.045 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m
Coefficient for per m of WR0201
Code Description Quant Units LB0056 Wireman Gd.1 0.045 day LB0069 Wireman Gd.2 0.045 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m
Coefficient for per m of WR0215
Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m
Coefficient for per m of WR0216
Code Description Quant Units LB0056 Wireman Gd.1 0.057 day LB0069 Wireman Gd.2 0.057 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m
Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x10 sq.mm
WR0216
Rewiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x2.5 sq.mm
WR0201
Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x6 sq.mm
WR0215
Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x4 sq.mm
WR0187
Rewiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x2 sq.mm
WR0200
Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting testing and commissioning etc. as required - 2x1 sq.mm
WR0185
Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x1.5 sq.mm
WR0186
Labour and Material Coefficients (Electrical)- 2013 Page 125
Department of Engineering Services, MoWHS
Coefficient for per m of WR0217
Code Description Quant Units LB0056 Wireman Gd.1 0.0574 day LB0069 Wireman Gd.2 0.0574 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m
Coefficient for per m of WR0218
Code Description Quant Units LB0056 Wireman Gd.1 0.0574 day LB0069 Wireman Gd.2 0.0574 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m
Coefficient for per m of WR0219
Code Description Quant Units LB0056 Wireman Gd.1 0.063 day LB0069 Wireman Gd.2 0.063 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 4.04 m
Coefficient for per m of WR0220
Code Description Quant Units LB0056 Wireman Gd.1 0.063 day LB0069 Wireman Gd.2 0.063 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4.04 m
Coefficient for per point of WR0230
Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m
Coefficient for per point of WR0231
Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m
Rewiring of light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point
WR0231
Rewiring of light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point
WR0230
Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 4x16 sq.mm
WR0220
Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 4x6 sq.mm
WR0218
Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 4x10 sq.mm
WR0219
Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x16 sq.mm
WR0217
Labour and Material Coefficients (Electrical)- 2013 Page 126
Department of Engineering Services, MoWHS
Coefficient for per point of WR0232
Code Description Quant Units LB0056 Wireman Gd.1 0.4 day LB0069 Wireman Gd.2 0.4 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m
Coefficient for per point of WR0240
Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m
Coefficient for per point of WR0241
Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m
Coefficient for per point of WR0242
Code Description Quant Units LB0056 Wireman Gd.1 0.4 day LB0069 Wireman Gd.2 0.4 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m
Coefficient for per point of WR0250
Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m
Coefficient for per point of WR0251
Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m
requirement, painting, testing and commissioning etc. as required - Long Point
Rewiring of light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site
requirement, painting, testing and commissioning etc. as required - Short Point WR0240
Rewiring of light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site
Rewiring of light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site
requirement, painting, testing and commissioning etc. as required - Medium Point WR0241
Rewiring of light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point
WR0232
WR0242
WR0250
testing and commissioning etc. as required - Medium Point WR0251
Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting,
testing and commissioning etc. as required - Short Point
Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting,
Labour and Material Coefficients (Electrical)- 2013 Page 127
Department of Engineering Services, MoWHS
Coefficient for per point of WR0252
Code Description Quant Units LB0056 Wireman Gd.1 0.4 day LB0069 Wireman Gd.2 0.4 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m
Coefficient for per point of WR0260
Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m
Coefficient for per point of WR0261
Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m
Coefficient for per point of WR0262
Code Description Quant Units LB0056 Wireman Gd.1 0.4 day LB0069 Wireman Gd.2 0.4 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m
Coefficient for per point of WR0270
Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m
Coefficient for per point of WR0271
Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m
Coefficient for per point of WR0272
Code Description Quant Units LB0056 Wireman Gd.1 0.4 day LB0069 Wireman Gd.2 0.4 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m
Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point
WR0252
Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement,painting, testing and commissioning etc. as required - Short Point
WR0260
Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point
WR0261
Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point
WR0262
Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point
WR0270
Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point
WR0271
Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point
WR0272
Labour and Material Coefficients (Electrical)- 2013 Page 128
Department of Engineering Services, MoWHS
Coefficient for per point of WR0280
Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m
Coefficient for per point of WR0281
Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m
Coefficient for per point of WR0282
Code Description Quant Units LB0056 Wireman Gd.1 0.4 day LB0069 Wireman Gd.2 0.4 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m
Coefficient for per point of WR0290
Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m
Coefficient for per point of WR0291
Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m
Coefficient for per point of WR0292
Code Description Quant Units LB0056 Wireman Gd.1 0.4 day LB0069 Wireman Gd.2 0.4 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m
Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement , painting,testing and commissioning etc. as required - Short Point
WR0280
Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point
WR0281
Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point
WR0282
Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point
WR0290
Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point
WR0291
Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point
WR0292
Labour and Material Coefficients (Electrical)- 2013 Page 129
Department of Engineering Services, MoWHS
Coefficient for per m of WR0300
Code Description Quant Units LB0056 Wireman Gd.1 0.0304 day LB0069 Wireman Gd.2 0.0304 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m
Coefficient for per m of WR0301
Code Description Quant Units LB0056 Wireman Gd.1 0.0304 day LB0069 Wireman Gd.2 0.0304 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m
Coefficient for per m of WR0302
Code Description Quant Units LB0056 Wireman Gd.1 0.0338 day LB0069 Wireman Gd.2 0.0338 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m
Coefficient for per m of WR0315
Code Description Quant Units LB0056 Wireman Gd.1 0.0304 day LB0069 Wireman Gd.2 0.0304 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m
Coefficient for per m of WR0316
Code Description Quant Units LB0056 Wireman Gd.1 0.0304 day LB0069 Wireman Gd.2 0.0304 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m
Coefficient for per m of WR0330
Code Description Quant Units LB0056 Wireman Gd.1 0.0338 day LB0069 Wireman Gd.2 0.0338 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m
Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x1 sq.mm
WR0300
Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x1.5 sq.mm
WR0301
Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x4 sq.mm
WR0302
Rewiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x2 sq.mm
WR0315
Rewiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x2.5 sq.mm
WR0316
Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x6 sq.mm
WR0330
Labour and Material Coefficients (Electrical)- 2013 Page 130
Department of Engineering Services, MoWHS
Coefficient for per m of WR0331
Code Description Quant Units LB0056 Wireman Gd.1 0.037 day LB0069 Wireman Gd.2 0.037 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m
Coefficient for per m of WR0332
Code Description Quant Units LB0056 Wireman Gd.1 0.037 day LB0069 Wireman Gd.2 0.037 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m
Coefficient for per point of WR0345
Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m
Coefficient for per point of WR0346
Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.25 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m
Coefficient for per point of WR0347
Code Description Quant Units LB0056 Wireman Gd.1 0.4286 day LB0067 Painter Gd.2 0.2143 day LB0069 Wireman Gd.2 0.4286 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m
Coefficient for per point of WR0355
Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m
Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x10 sq.mm
WR0331
Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x16 sq.mm
WR0332
Rewiring of light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point
WR0345
Rewiring of light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. asrequired - Medium Point
WR0346
Rewiring of light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point
WR0347
Rewiring of light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point
WR0355
Labour and Material Coefficients (Electrical)- 2013 Page 131
Department of Engineering Services, MoWHS
Coefficient for per point of WR0356
Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m
Coefficient for per point of WR0357
Code Description Quant Units LB0056 Wireman Gd.1 0.4286 day LB0067 Painter Gd.2 0.2143 day LB0069 Wireman Gd.2 0.4286 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m
Coefficient for per point of WR0365
Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m
Coefficient for per point of WR0366
Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.25 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m
Coefficient for per point of WR0367
Code Description Quant Units LB0056 Wireman Gd.1 0.4286 day LB0067 Painter Gd.2 0.2143 day LB0069 Wireman Gd.2 0.4286 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m
Coefficient for per point of WR0375
Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m
painting, testing and commissioning etc. as required - Medium Point WR0366
painting, testing and commissioning etc. as required - Short Point WR0375
Rewiring of light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point
WR0356
Rewiring of light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point
WR0357
Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point
WR0365
Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement,
Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, testing and commissioning etc. as required - Long Point
WR0367
Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement,
Labour and Material Coefficients (Electrical)- 2013 Page 132
Department of Engineering Services, MoWHS
Coefficient for per point of WR0376
Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.25 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m
Coefficient for per point of WR0377
Code Description Quant Units LB0056 Wireman Gd.1 0.4286 day LB0067 Painter Gd.2 0.2143 day LB0069 Wireman Gd.2 0.4286 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m
Coefficient for per point of WR0385
Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m
Coefficient for per point of WR0386
Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.25 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m
Coefficient for per point of WR0387
Code Description Quant Units LB0056 Wireman Gd.1 0.4286 day LB0067 Painter Gd.2 0.2143 day LB0069 Wireman Gd.2 0.4286 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m
commissioning etc. as required - Long Point WR0387
commissioning etc. as required - Short Point WR0385
Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point
WR0386
Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and
Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point
WR0376
Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point
WR0377
Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and
Labour and Material Coefficients (Electrical)- 2013 Page 133
Department of Engineering Services, MoWHS
Coefficient for per point of WR0395
Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m
Coefficient for per point of WR0396
Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m
Coefficient for per point of WR0397
Code Description Quant Units LB0056 Wireman Gd.1 0.4286 day LB0067 Painter Gd.2 0.2143 day LB0069 Wireman Gd.2 0.4286 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m
Coefficient for per point of WR0405
Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m
Coefficient for per point of WR0406
Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.25 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m
Coefficient for per point of WR0407
Code Description Quant Units LB0056 Wireman Gd.1 0.4286 day LB0067 Painter Gd.2 0.2143 day LB0069 Wireman Gd.2 0.4286 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m
requirement, painting, testing and commissioning etc. as required - Long Point WR0407
requirement, painting, testing and commissioning etc. as required - Short Point WR0405
Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point
WR0406
Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site
and commissioning etc. as required - Medium Point WR0396
Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point
WR0397
Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site
Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testingand commissioning etc. as required - Short Point
WR0395
Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing
Labour and Material Coefficients (Electrical)- 2013 Page 134
Department of Engineering Services, MoWHS
Coefficient for per m of WR0415
Code Description Quant Units LB0056 Wireman Gd.1 0.0332 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0332 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m
Coefficient for per m of WR0416
Code Description Quant Units LB0056 Wireman Gd.1 0.0332 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0332 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m
Coefficient for per m of WR0417
Code Description Quant Units LB0056 Wireman Gd.1 0.0354 day LB0067 Painter Gd.2 0.0266 day LB0069 Wireman Gd.2 0.0354 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m
Coefficient for per m of WR0430
Code Description Quant Units LB0056 Wireman Gd.1 0.0332 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0332 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m
Coefficient for per m of WR0431
Code Description Quant Units LB0056 Wireman Gd.1 0.0332 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0332 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m
Coefficient for per m of WR0445
Code Description Quant Units LB0056 Wireman Gd.1 0.0354 day LB0067 Painter Gd.2 0.0266 day LB0069 Wireman Gd.2 0.0354 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m
and commissioning etc. as required - 2x6 sq.mm WR0445
and commissioning etc. as required - 2x2 sq.mm WR0430
Rewiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x2.5 sq.mm
WR0431
Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing
painting, testing and commissioning etc. as required - 2x1.5 sq.mm WR0416
Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x4 sq.mm
WR0417
Rewiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing
Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x1 sq.mm
WR0415
Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement,
Labour and Material Coefficients (Electrical)- 2013 Page 135
Department of Engineering Services, MoWHS
Coefficient for per m of WR0446
Code Description Quant Units LB0056 Wireman Gd.1 0.0372 day LB0067 Painter Gd.2 0.0266 day LB0069 Wireman Gd.2 0.0372 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m
Coefficient for per m of WR0447
Code Description Quant Units LB0056 Wireman Gd.1 0.0372 day LB0067 Painter Gd.2 0.0266 day LB0069 Wireman Gd.2 0.0372 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m
Coefficient for per m of WR0448
Code Description Quant Units LB0056 Wireman Gd.1 0.0354 day LB0067 Painter Gd.2 0.0278 day LB0069 Wireman Gd.2 0.0354 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m
Coefficient for per m of WR0449
Code Description Quant Units LB0056 Wireman Gd.1 0.0408 day LB0067 Painter Gd.2 0.03 day LB0069 Wireman Gd.2 0.0408 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 4.04 m
Coefficient for per m of WR0450
Code Description Quant Units LB0056 Wireman Gd.1 0.0408 day LB0067 Painter Gd.2 0.03 day LB0069 Wireman Gd.2 0.0408 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4.04 m
CHAPTER 7: CONDUITING
CD0045
Coefficient for per m of CD0045
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.0472 day
and commissioning etc. as required - 4x10 sq.mm
Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing WR0449
Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 4x16 sq.mm
WR0450
Supplying and fixing of PVC casing & capping on surface including cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - 13x12x1.2mm
and commissioning etc. as required - 2x16 sq.mm WR0447
Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 4x6 sq.mm
WR0448
Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x10 sq.mm
WR0446
Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing
Labour and Material Coefficients (Electrical)- 2013 Page 136
Department of Engineering Services, MoWHS
MT4873 PVC sleev 25mm 6.6 each MT4940 PVC Casing & Cappings - 12x12 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m
CD0046
Coefficient for per m of CD0046
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.0472 day MT4873 PVC sleev 25mm 6.6 each MT4944 PVC Casing & Cappings - 20x12 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m
CD0047
Coefficient for per m of CD0047
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.0524 day MT4873 PVC sleev 25mm 6.6 each MT4945 PVC Casing & Cappings - 25x10 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.3 m
CD0048
Coefficient for per m of CD0048
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.0524 day MT4873 PVC sleev 25mm 6.6 each MT4946 PVC Casing & Cappings - 30x10 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.3 m
CD0049
Coefficient for per m of CD0049
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.032 day LB0069 Wireman Gd.2 0.056 day MT4873 PVC sleev 25mm 6.6 each MT4947 PVC Casing & Cappings - 40x20 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.3 m
CD0050
Coefficient for per m of CD0050
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.032 day LB0069 Wireman Gd.2 0.056 day MT4873 PVC sleev 25mm 6.6 each MT4948 PVC Casing & Cappings - 50x20 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.3 m
Supplying and fixing of PVC casing & capping on surface including cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - 20x12x1.2mm
Supplying and fixing of PVC casing & capping on surface including cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - 25x10x1.2mm
Supplying and fixing of PVC casing & capping on surface including cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - 32x10x1.2mm
Supplying and fixing of PVC casing & capping on surface including cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - 40x10x1.2mm
Supplying and fixing of PVC casing & capping on surface including cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - 50x10x1.2mm
Labour and Material Coefficients (Electrical)- 2013 Page 137
Department of Engineering Services, MoWHS
Coefficient for per point of CD0060
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4860 PVC Boxes - 1 Module 1 each MT4873 PVC sleev 25mm 19 each MT4940 PVC Casing & Cappings - 12x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m
Coefficient for per point of CD0061
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.11 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.27 day MT4860 PVC Boxes - 1 Module 1 each MT4873 PVC sleev 25mm 39 each MT4940 PVC Casing & Cappings - 12x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m
Coefficient for per point of CD0062
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4860 PVC Boxes - 1 Module 1 each MT4873 PVC sleev 25mm 62 each MT4940 PVC Casing & Cappings - 12x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m
Coefficient for per point of CD0070
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4860 PVC Boxes - 1 Module 1 each MT4873 PVC sleev 25mm 19 each MT4944 PVC Casing & Cappings - 20x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m
as required - Short Point
Supplying and fixing of PVC casing & capping on surface for twin control light point with all accessories such as switch board, round block, cup washer, screws, bends, elbows, Tees, corners, etc. complete
cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point CD0061
Supplying and fixing of PVC casing & capping on surface for light /call bell/fan/ 2 pin socket outlet/ 3/5 pin 6 ampere plug point along with all accessories such as switch board, round block, cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point
CD0062
cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - Short Point CD0060
Supplying and fixing of PVC casing & capping on surface for light /call bell/fan/ 2 pin socket outlet/ 3/5 pin 6 ampere plug point along with all accessories such as switch board, round block,
CD0070
Supplying and fixing of PVC casing & capping on surface for light /call bell/fan/ 2 pin socket outlet/ 3/5 pin 6 ampere plug point along with all accessories such as switch board, round block,
Labour and Material Coefficients (Electrical)- 2013 Page 138
Department of Engineering Services, MoWHS
Coefficient for per point of CD0071
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.11 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.27 day MT4860 PVC Boxes - 1 Module 1 each MT4873 PVC sleev 25mm 39 each MT4944 PVC Casing & Cappings - 20x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m
Coefficient for per point of CD0072
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4860 PVC Boxes - 1 Module 1 each MT4873 PVC sleev 25mm 62 each MT4944 PVC Casing & Cappings - 20x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m
Coefficient for per point of CD0080
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4863 PVC Boxes - 4 Module 1 each MT4873 PVC sleev 25mm 19 each MT4944 PVC Casing & Cappings - 20x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m
Coefficient for per point of CD0081
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.11 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.27 day MT4863 PVC Boxes - 4 Module 1 each MT4873 PVC sleev 25mm 39 each MT4944 PVC Casing & Cappings - 20x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m
complete as required - Medium Point
Supplying and fixing of PVC casing & capping on surface for 3/5 pin 6/16 ampere plug point along with all accessories such as switch board, round block, cup washer, screws, bends, elbows, Tees, corners, etc.
Supplying and fixing of PVC casing & capping on surface for twin control light point with all accessories such as switch board, round block, cup washer, screws, bends, elbows, Tees, corners, etc. complete
CD0081
as required - Long Point CD0072
Supplying and fixing of PVC casing & capping on surface for 3/5 pin 6/16 ampere plug point along with all accessories such as switch board, round block, cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - Short Point
CD0080
Supplying and fixing of PVC casing & capping on surface for twin control light point with all accessories such as switch board, round block, cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point
CD0071
Labour and Material Coefficients (Electrical)- 2013 Page 139
Department of Engineering Services, MoWHS
Coefficient for per point of CD0082
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4863 PVC Boxes - 4 Module 1 each MT4873 PVC sleev 25mm 62 each MT4944 PVC Casing & Cappings - 20x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m
CD0090
Coefficient for per m of CD0090
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.0472 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4840 PVC Conduit - 20 mm,18SWG 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 3.4 each
CD0091
Coefficient for per m of CD0091
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.0524 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4841 PVC Conduit - 25 mm,16SWG 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 3.4 each
CD0092
Coefficient for per m of CD0092
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.0524 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4842 PVC Conduit - 32 mm,14SWG 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 3.4 each
CD0093
Coefficient for per m of CD0093
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day
Supplying and fixing of PVC conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 25mm
Supplying and fixing of PVC conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 32mm
Supplying and fixing of PVC conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 40mm
Supplying and fixing of PVC casing & capping on surface for 3/5 pin 6/16 ampere plug point along with all accessories such as switch board, round block, cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point
CD0082
Supplying and fixing of PVC conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 20mm
Labour and Material Coefficients (Electrical)- 2013 Page 140
Department of Engineering Services, MoWHS
LB0056 Wireman Gd.1 0.052 day LB0069 Wireman Gd.2 0.056 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4843 PVC Conduit - 40 mm,14SWG 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 3.4 each
CD0094
Coefficient for per m of CD0094
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.052 day LB0069 Wireman Gd.2 0.056 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4844 PVC Conduit - 50 mm,14SWG 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 3.4 each
Coefficient for per point of CD0105
Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 2 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each
Coefficient for per point of CD0106
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.11 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.27 day MT4809 M.S Coduit - M.S Saddle 9 each MT4840 PVC Conduit - 20 mm,18SWG 5 m MT4860 PVC Boxes - 1 Module 1 each MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 21 each
as required - Medium Point
CD0105
CD0106
Supplying and fixing of PVC conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 50mm
Supplying and fixing of PVC conduit on surface for light call bell/fan/ 2 pin socket outlet along with all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. complete as required - Short Point
Supplying and fixing of PVC conduit on surface for light call bell/fan/ 2 pin socket outlet along with all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. complete
Labour and Material Coefficients (Electrical)- 2013 Page 141
Department of Engineering Services, MoWHS
Coefficient for per point of CD0107
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4809 M.S Coduit - M.S Saddle 15 each MT4840 PVC Conduit - 20 mm,18SWG 8.5 m MT4860 PVC Boxes - 1 Module 1 each MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 33 each
CD0115
Coefficient for per point of CD0115
Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 2 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each
CD0116
Coefficient for per point of CD0116
Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 2 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 21 each
CD0117
Coefficient for per point of CD0117
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4809 M.S Coduit - M.S Saddle 15 each
as required - Long Point
Supplying and fixing of PVC conduit on surface for light call bell/fan/ 2 pin socket outlet along with all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. complete
Supplying and fixing of PVC conduit on surface for twin control light point along with all accessories such as switch board, screws, bends, elbows, Tees, corners, etc. complete as required -Short Point
Supplying and fixing of PVC conduit on surface for twin control light point along with all accessories such as switch board, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point
Supplying and fixing of PVC conduit on surface for twin control light point along with all accessories such as switch board, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point
CD0107
Labour and Material Coefficients (Electrical)- 2013 Page 142
Department of Engineering Services, MoWHS
MT4840 PVC Conduit - 20 mm,18SWG 8.5 m MT4860 PVC Boxes - 1 Module 1 each MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 33 each
Coefficient for per point of CD0125
Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 2 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each
Coefficient for per point of CD0126
Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 2 m MT4863 PVC Boxes - 4 Module 1 each
MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 21 each
Coefficient for per point of CD0127
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4809 M.S Coduit - M.S Saddle 15 each MT4840 PVC Conduit - 20 mm,18SWG 8.5 m MT4863 PVC Boxes - 4 Module 1 each MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 33 each
complete as required - Long Point
Supplying and fixing of PVC conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc.
CD0125
CD0127
Supplying and fixing of PVC conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc.complete as required - Short Point
Supplying and fixing of PVC conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point
CD0126
Labour and Material Coefficients (Electrical)- 2013 Page 143
Department of Engineering Services, MoWHS
CD0135
Coefficient for per m of CD0135
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.0472 day MT4820 Steel Conduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 1.7 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 3.4 each
CD0136
Coefficient for per m of CD0136
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.0524 day MT4821 Steel Conduit - 25mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 1.7 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 3.4 each
CD0137
Coefficient for per m of CD0137
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.0524 day MT4822 Steel Conduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 1.7 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 3.4 each
CD0138
Coefficient for per m of CD0138
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.052 day LB0069 Wireman Gd.2 0.056 day MT4823 Steel Conduit - 40mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 1.7 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 3.4 each
CD0139
Coefficient for per m of CD0139
Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.052 day
Supplying and fixing of Stainless steel conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 20mm
Supplying and fixing of Stainless steel conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 25mm
Supplying and fixing of Stainless steel conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 32mm
Supplying and fixing of Stainless steel conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc.complete as required - 40mm
Supplying and fixing of Stainless steel conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 50mm
Labour and Material Coefficients (Electrical)- 2013 Page 144
Department of Engineering Services, MoWHS
LB0069 Wireman Gd.2 0.056 day MT4824 Steel Conduit - 50mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 1.7 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 3.4 each
Coefficient for per point of CD0150
Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4820 Steel Conduit - 20mm x 1.6mm 2 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 19 each MT5900 Metal boxes - 1 Module 1 each
Coefficient for per point of CD0151
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.11 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.27 day MT4820 Steel Conduit - 20mm x 1.6mm 5 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 39 each MT5900 Metal boxes - 1 Module 1 each
Coefficient for per point of CD0152
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4820 Steel Conduit - 20mm x 1.6mm 8.5 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 62 each MT5900 Metal boxes - 1 Module 1 each
Supplying and fixing of Stainless steel conduit on surface for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc.complete as required - Short Point
CD0150
Supplying and fixing of Stainless steel conduit on surface for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc.complete as required - Medium Point
CD0151
Supplying and fixing of Stainless steel conduit on surface for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc.complete as required - Long Point
CD152
Labour and Material Coefficients (Electrical)- 2013 Page 145
Department of Engineering Services, MoWHS
Coefficient for per point of CD0160
Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4820 Steel Conduit - 20mm x 1.6mm 2 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 19 each MT5900 Metal boxes - 1 Module 1 each
Coefficient for per point of CD0161
Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4820 Steel Conduit - 20mm x 1.6mm 2 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 39 each MT5900 Metal boxes - 1 Module 1 each
Coefficient for per point of CD0162
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4820 Steel Conduit - 20mm x 1.6mm 8.5 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 62 each MT5900 Metal boxes - 1 Module 1 each
Coefficient for per point of CD0170
Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4820 Steel Conduit - 20mm x 1.6mm 2 m
Supplying and fixing of Stainless steel conduit on surface for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete asrequired - Short Point
CD0160
Supplying and fixing of Stainless steel conduit on surface for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point
CD0161
Supplying and fixing of Stainless steel conduit on surface for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point
CD0162
Supplying and fixing of Stainless steel conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Short Point
CD0170
Labour and Material Coefficients (Electrical)- 2013 Page 146
Department of Engineering Services, MoWHS
MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 19 each MT5903 Metal boxes - 4 Module 1 each
Coefficient for per point of CD0171
Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4820 Steel Conduit - 20mm x 1.6mm 2 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each
MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 39 each MT5903 Metal boxes - 4 Module 1 each
Coefficient for per point of CD0172
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4820 Steel Conduit - 20mm x 1.6mm 8.5 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 62 each MT5903 Metal boxes - 4 Module 1 each
CD0180
Coefficient for per m of CD0180
Code Description Quant Units LB0051 Mason Gd.2 0.02 day LB0056 Wireman Gd.1 0.04 day LB0067 Painter Gd.2 0.0225 day LB0069 Wireman Gd.2 0.0625 day MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4807 M.S Coduit - Inspection bend 0.04 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 3.4 each
CD0181
Coefficient for per m of CD0181
Code Description Quant Units LB0051 Mason Gd.2 0.02 day LB0056 Wireman Gd.1 0.04 day
Supplying and fixing of Stainless steel conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point
CD0171
Supplying and fixing of Stainless steel conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point
CD0172
Supplying and fixing of MS conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete asrequired - 20mm
Supplying and fixing of MS conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 25mm
Labour and Material Coefficients (Electrical)- 2013 Page 147
Department of Engineering Services, MoWHS
LB0067 Painter Gd.2 0.0225 day LB0069 Wireman Gd.2 0.0625 day MT4802 M.S Coduit - 25mm x 1.6mm 1 m MT4807 M.S Coduit - Inspection bend 0.08 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 3.4 each
CD0182
Coefficient for per m of CD0182
Code Description Quant Units LB0051 Mason Gd.2 0.025 day LB0056 Wireman Gd.1 0.0425 day LB0067 Painter Gd.2 0.0225 day LB0069 Wireman Gd.2 0.065 day MT4803 M.S Coduit - 32mm x 2mm 1 m MT4807 M.S Coduit - Inspection bend 0.08 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 3.4 each
CD0183
Coefficient for per m of CD0183
Code Description Quant Units LB0051 Mason Gd.2 0.025 day LB0056 Wireman Gd.1 0.0425 day LB0067 Painter Gd.2 0.0225 day LB0069 Wireman Gd.2 0.065 day MT4804 M.S Coduit - 40mm x 2mm 1 m MT4807 M.S Coduit - Inspection bend 0.08 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 3.4 each
CD0184
Coefficient for per m of CD0184
Code Description Quant Units LB0051 Mason Gd.2 0.02 day LB0056 Wireman Gd.1 0.045 day LB0067 Painter Gd.2 0.0225 day LB0069 Wireman Gd.2 0.0675 day MT4805 M.S Coduit - 50mm x 2mm 1 m MT4807 M.S Coduit - Inspection bend 0.08 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 3.4 each
Coefficient for per point of CD0195
Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.137 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.212 day MT4801 M.S Coduit - 20mm x 1.6mm 2 m
Supplying and fixing of MS conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 32mm
Supplying and fixing of MS conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 40mm
Supplying and fixing of MS conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 50mm
Supplying and fixing of MS conduit on surface for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Short Point
CD0195
Labour and Material Coefficients (Electrical)- 2013 Page 148
Department of Engineering Services, MoWHS
MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4809 M.S Coduit - M.S Saddle 4 each MT4874 PVC sleev 35mm 3.4 each MT5900 Metal boxes - 1 Module 1 each
Coefficient for per point of CD0196
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.275 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.4 day MT4801 M.S Coduit - 20mm x 1.6mm 5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 2 each MT4809 M.S Coduit - M.S Saddle 9 each MT4874 PVC sleev 35mm 3.4 each MT5900 Metal boxes - 1 Module 1 each
Coefficient for per point of CD0197
Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.3643 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.6143 day MT4801 M.S Coduit - 20mm x 1.6mm 8.5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 3 each MT4809 M.S Coduit - M.S Saddle 15 each MT4874 PVC sleev 35mm 3.4 each MT5900 Metal boxes - 1 Module 1 each
Coefficient for per point of CD0200
Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.137 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.212 day MT4801 M.S Coduit - 20mm x 1.6mm 2 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4809 M.S Coduit - M.S Saddle 4 each MT4874 PVC sleev 35mm 12 each MT5900 Metal boxes - 1 Module 1 each
Supplying and fixing of MS conduit on surface for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point
CD0196
Supplying and fixing of MS conduit on surface for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point
CD0197
Supplying and fixing of MS conduit on surface for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as requiredrequired - Short Point
CD0200
Labour and Material Coefficients (Electrical)- 2013 Page 149
Department of Engineering Services, MoWHS
Coefficient for per point of CD0201
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.275 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.4 day MT4801 M.S Coduit - 20mm x 1.6mm 2 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each
MT4808 M.S Coduit - socket for conduit 2 each MT4809 M.S Coduit - M.S Saddle 4 each MT4874 PVC sleev 35mm 21 each MT5900 Metal boxes - 1 Module 1 each
Coefficient for per point of CD0202
Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.3643 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.6143 day MT4801 M.S Coduit - 20mm x 1.6mm 8.5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 3 each MT4809 M.S Coduit - M.S Saddle 15 each MT4874 PVC sleev 35mm 33 each MT5900 Metal boxes - 1 Module 1 each
Coefficient for per point of CD0210
Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.137 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.212 day MT4801 M.S Coduit - 20mm x 1.6mm 2 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4809 M.S Coduit - M.S Saddle 4 each MT4874 PVC sleev 35mm 12 each MT5903 Metal boxes - 4 Module 1 each
Coefficient for per point of CD0211
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.275 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.4 day
Supplying and fixing of MS conduit on surface for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required-Medium Point
CD0201
Supplying and fixing of MS conduit on surface for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required-Long Point
CD0202
Supplying and fixing of MS conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Short Point
CD0210
Supplying and fixing of MS conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point
CD0211
Labour and Material Coefficients (Electrical)- 2013 Page 150
Department of Engineering Services, MoWHS
MT4801 M.S Coduit - 20mm x 1.6mm 2 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each
MT4808 M.S Coduit - socket for conduit 2 each MT4809 M.S Coduit - M.S Saddle 4 each MT4874 PVC sleev 35mm 21 each MT5903 Metal boxes - 4 Module 1 each
Coefficient for per point of CD0212
Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.3643 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.6143 day MT4801 M.S Coduit - 20mm x 1.6mm 8.5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 3 each MT4809 M.S Coduit - M.S Saddle 15 each MT4874 PVC sleev 35mm 33 each MT5903 Metal boxes - 4 Module 1 each
CD0220
Coefficient for per m of CD0220
Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0352 day LB0069 Wireman Gd.2 0.1232 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4850 HDPE pipe - 20mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 2 each
CD0221
Coefficient for per m of CD0221
Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0352 day LB0069 Wireman Gd.2 0.1232 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4851 HDPE pipe - 25mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 2 each
CD0222
Coefficient for per m of CD0222
Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0374 day LB0069 Wireman Gd.2 0.1254 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4852 HDPE pipe - 32mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 2 each
Supplying and fixing of MS conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point
CD0212
Supplying and fixing of HDPE pipe on recessed including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 20mm
Supplying and fixing of HDPE pipe on recessed including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 25mm
Supplying and fixing of HDPE pipe on recessed including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 32mm
Labour and Material Coefficients (Electrical)- 2013 Page 151
Department of Engineering Services, MoWHS
CD0223
Coefficient for per m of CD00223
Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0374 day LB0069 Wireman Gd.2 0.1254 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4853 HDPE pipe - 40mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 2 each
CD0224
Coefficient for per m of CD0224
Code Description Quant Units LB0051 Mason Gd.2 0.1004 day LB0056 Wireman Gd.1 0.0396 day LB0069 Wireman Gd.2 0.1276 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4854 HDPE pipe - 50mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 2 each
Coefficient for per point of CD0235
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.0833 day LB0069 Wireman Gd.2 0.525 day MT4809 M.S Coduit - M.S Saddle 3 each MT4850 HDPE pipe - 20mm 2 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 9 each
Coefficient for per point of CD0236
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.1666 day LB0069 Wireman Gd.2 0.825 day MT4809 M.S Coduit - M.S Saddle 5 each MT4850 HDPE pipe - 20mm 5 m MT4860 PVC Boxes - 1 Module 1 each MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 13 each
as required - Medium Point
Supplying and fixing of HDPE pipe on recessed for light call bell/fan/ 2 pin socket outlet along with all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. complete
Supplying and fixing of HDPE pipe on recessed including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 40mm
CD0235
CD0236
Supplying and fixing of HDPE pipe on recessed for light call bell/fan/ 2 pin socket outlet along with all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. complete as required - Short Point
Supplying and fixing of HDPE pipe on recessed including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 50mm
Labour and Material Coefficients (Electrical)- 2013 Page 152
Department of Engineering Services, MoWHS
Coefficient for per point of CD0237
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 1.125 day MT4809 M.S Coduit - M.S Saddle 8 each MT4850 HDPE pipe - 20mm 8.5 m MT4860 PVC Boxes - 1 Module 1 each MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 19 each
Coefficient for per point of CD0245
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.0833 day LB0069 Wireman Gd.2 0.525 day MT4809 M.S Coduit - M.S Saddle 3 each MT4850 HDPE pipe - 20mm 2 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 9 each
CD0246
Coefficient for per point of CD0246
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.1666 day LB0069 Wireman Gd.2 0.825 day MT4809 M.S Coduit - M.S Saddle 5 each MT4850 HDPE pipe - 20mm 5 m MT4860 PVC Boxes - 1 Module 1 each MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 13 each
CD0247
Coefficient for per point of CD0247
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 1.125 day MT4809 M.S Coduit - M.S Saddle 8 each MT4850 HDPE pipe - 20mm 8.5 m MT4860 PVC Boxes - 1 Module 1 each MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 19 each
Supplying and fixing of HDPE pipe on recessed for twin control light point along with all accessories such as switch board, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point
as required - Long Point
Supplying and fixing of HDPE pipe on recessed for light call bell/fan/ 2 pin socket outlet along with all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. complete
Short Point
CD0237
CD0245
Supplying and fixing of HDPE pipe on recessed for twin control light point along with all accessories such as switch board, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point
Supplying and fixing of HDPE pipe on recessed for twin control light point along with all accessories such as switch board, screws, bends, elbows, Tees, corners, etc. complete as required-
Labour and Material Coefficients (Electrical)- 2013 Page 153
Department of Engineering Services, MoWHS
Coefficient for per point of CD0255
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.0833 day LB0069 Wireman Gd.2 0.525 day MT4809 M.S Coduit - M.S Saddle 3 each MT4850 HDPE pipe - 20mm 2 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 9 each
Coefficient for per point of CD0256
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.1666 day LB0069 Wireman Gd.2 0.825 day MT4809 M.S Coduit - M.S Saddle 5 each MT4850 HDPE pipe - 20mm 5 m MT4863 PVC Boxes - 4 Module 1 each MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 13 each
Coefficient for per point of CD0257
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 1.125 day MT4809 M.S Coduit - M.S Saddle 8 each MT4850 HDPE pipe - 20mm 8.5 m MT4863 PVC Boxes - 4 Module 1 each MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 19 each
CD0265
Coefficient for per m of CD0265
Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.14 day MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4807 M.S Coduit - Inspection bend 0.04 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 2 each
complete as required - Short Point
Supplying and fixing of HDPE pipe on recessed for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc.
Supplying and fixing of HDPE pipe on recessed for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point
CD0255
complete as required - Medium Point CD0256
CD0257
Supplying and fixing of recessed MS conduit including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 20mm
Supplying and fixing of HDPE pipe on recessed for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc.
Labour and Material Coefficients (Electrical)- 2013 Page 154
Department of Engineering Services, MoWHS
CD0266
Coefficient for per m of CD0266
Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.14 day MT4802 M.S Coduit - 25mm x 1.6mm 1 m MT4807 M.S Coduit - Inspection bend 0.08 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 2 each
CD0267
Coefficient for per m of CD0267
Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0425 day LB0069 Wireman Gd.2 0.1425 day MT4803 M.S Coduit - 32mm x 2mm 1 m MT4807 M.S Coduit - Inspection bend 0.08 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 2 each
CD0268
Coefficient for per m of CD0268
Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0425 day LB0069 Wireman Gd.2 0.1425 day MT4804 M.S Coduit - 40mm x 2mm 1 m MT4807 M.S Coduit - Inspection bend 0.08 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 2 each
CD0269
Coefficient for per m of CD0269
Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.045 day LB0069 Wireman Gd.2 0.145 day MT4805 M.S Coduit - 50mm x 2mm 1 m MT4807 M.S Coduit - Inspection bend 0.08 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 2 each
Coefficient for per point of CD0280
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.0833 day
as required - Short Point
Supplying and fixing of recessed MS conduit for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. complete
Supplying and fixing of recessed MS conduit including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 50mm
Supplying and fixing of recessed MS conduit including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 40mm
CD0280
Supplying and fixing of recessed MS conduit including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 25mm
Supplying and fixing of recessed MS conduit including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 32mm
Labour and Material Coefficients (Electrical)- 2013 Page 155
Department of Engineering Services, MoWHS
LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 0.5833 day MT4801 M.S Coduit - 20mm x 1.6mm 2 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4809 M.S Coduit - M.S Saddle 3 each MT4874 PVC sleev 35mm 9 each MT5900 Metal boxes - 1 Module 1 each
Coefficient for per point of CD0281
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.1666 day LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 0.9166 day MT4801 M.S Coduit - 20mm x 1.6mm 5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 2 each MT4809 M.S Coduit - M.S Saddle 5 each MT4874 PVC sleev 35mm 13 each MT5900 Metal boxes - 1 Module 1 each
Coefficient for per point of CD0282
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 1.25 day MT4801 M.S Coduit - 20mm x 1.6mm 8.5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 3 each MT4809 M.S Coduit - M.S Saddle 8 each MT4874 PVC sleev 35mm 19 each MT5900 Metal boxes - 1 Module 1 each
Coefficient for per point of CD0290
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.0833 day LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 0.5833 day MT4801 M.S Coduit - 20mm x 1.6mm 2 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4809 M.S Coduit - M.S Saddle 3 each MT4874 PVC sleev 35mm 9 each MT5900 Metal boxes - 1 Module 1 each
Supplying and fixing of recessed MS conduit for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Short Point
CD0290
Supplying and fixing of recessed MS conduit for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. completeas required - Medium Point
CD0281
Supplying and fixing of recessed MS conduit for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. complete required - Long Point
CD0282
Labour and Material Coefficients (Electrical)- 2013 Page 156
Department of Engineering Services, MoWHS
Coefficient for per point of CD0291
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.1666 day LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 0.9166 day MT4801 M.S Coduit - 20mm x 1.6mm 5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 2 each MT4809 M.S Coduit - M.S Saddle 5 each MT4874 PVC sleev 35mm 13 each MT5900 Metal boxes - 1 Module 1 each
Coefficient for per point of CD0292
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 1.25 day MT4801 M.S Coduit - 20mm x 1.6mm 8.5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 3 each MT4809 M.S Coduit - M.S Saddle 8 each MT4874 PVC sleev 35mm 19 each MT5900 Metal boxes - 1 Module 1 each
Coefficient for per point of CD0300
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.0833 day LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 0.5833 day MT4801 M.S Coduit - 20mm x 1.6mm 2 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4809 M.S Coduit - M.S Saddle 3 each MT4874 PVC sleev 35mm 9 each MT5903 Metal boxes - 4 Module 1 each
Coefficient for per point of CD0301
Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.1666 day LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 0.9166 day MT4801 M.S Coduit - 20mm x 1.6mm 5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each
Supplying and fixing of recessed MS conduit for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, complete as required - Medium Point
CD0301
Supplying and fixing of recessed MS conduit for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point
CD0292
Supplying and fixing of recessed MS conduit for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners,etc.etc. complete as required - Short Point
CD0300
Supplying and fixing of recessed MS conduit for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required -Medium Point
CD0291
Labour and Material Coefficients (Electrical)- 2013 Page 157
Department of Engineering Services, MoWHS
MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 2 each MT4809 M.S Coduit - M.S Saddle 5 each MT4874 PVC sleev 35mm 13 each MT5903 Metal boxes - 4 Module 1 each
Coefficient for per point of CD0302
Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 1.25 day MT4801 M.S Coduit - 20mm x 1.6mm 8.5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 3 each MT4809 M.S Coduit - M.S Saddle 8 each MT4874 PVC sleev 35mm 19 each MT5903 Metal boxes - 4 Module 1 each
CD0310
Coefficient for per m of CD0310Code Description Quant UnitsLB0051 Mason Gd.2 0.0224 dayLB0056 Wireman Gd.1 0.032 dayLB0069 Wireman Gd.2 0.056 dayMT7000 Mini trunking 32x12.5mm 1 mMT7002 Changeable internal angle 0.3 eachMT7002 Changeable external angle 0.21 eachMT7003 Changeable flat angle 0.32 eachMT7001 End cap 0.03 each
CD0311
Coefficient for per m of CD0311Code Description Quant UnitsLB0051 Mason Gd.2 0.0224 dayLB0056 Wireman Gd.1 0.032 dayLB0069 Wireman Gd.2 0.056 dayMT7005 Mini trunking 32x16mm 1 mMT7007 Changeable internal angle 0.3 eachMT7007 Changeable external angle 0.21 eachMT7008 Changeable flat angle 0.32 eachMT7006 End cap 0.03 each
CD0312
Coefficient for per m of CD0312Code Description Quant UnitsLB0051 Mason Gd.2 0.0224 dayLB0056 Wireman Gd.1 0.032 dayLB0069 Wireman Gd.2 0.056 dayMT7010 Mini trunking 32x20mm 1 mMT7007 Changeable internal angle 0.3 eachMT7007 Changeable external angle 0.21 eachMT7008 Changeable flat angle 0.32 eachMT7011 End cap 0.03 each
Supplying and fixing of recessed MS conduit for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. etc. complete as required - Long Point
CD0302
Suplying and fixing of PVC mini trunking on surface including changeable internal angles, external angles, flat anlges etc. complete as required- 32x20 mm
Suplying and fixing of PVC mini trunking on surface including changeable internal angles, external angles, flat anlges etc. complete as required- 32x12.5 mm
Suplying and fixing of PVC mini trunking on surface including changeable internal angles, external angles, flat anlges etc. complete as required- 32x16 mm
Labour and Material Coefficients (Electrical)- 2013 Page 158
Department of Engineering Services, MoWHS
Coefficient for per point of CD0320
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4860 PVC Boxes - 1 Module 1 each MT7000 Mini trunking 32x12.5mm 2 m MT7002 Changeable internal/external angle 1 each
MT7003 Changeable flat angle 1 eachMT7001 End cap 0.1 each
Coefficient for per point of CD0321
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.11 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.27 day MT4860 PVC Boxes - 1 Module 1 each MT7000 Mini trunking 32x12.5mm 5 m MT7002 Changeable internal/external angle 2 each
MT7003 Changeable flat angle 1 eachMT7001 End cap 0.2 each
Coefficient for per point of CD0322
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4860 PVC Boxes - 1 Module 1 each MT7000 Mini trunking 32x12.5mm 8.5 m MT7002 Changeable internal/external angle 2 each
MT7003 Changeable flat angle 1 eachMT7001 End cap 0.5 each
Coefficient for per point of CD0323
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4863 PVC Boxes - 4 Module 1 each MT7000 Mini trunking 32x12.5mm 2 m MT7002 Changeable internal/external angle 1 each MT7003 Changeable flat angle 1 each
MT7001 End cap 0.1 each
CD0320Supplying and fixing of PVC mini trunking on surface for light/call bell/fan/2-pin socket outlet/3/5-pin 6A plug point along with all accessories such as changeable internal/external/flat anlges, flat junction,end caps, switch box etc. complete as required- Short Point
complete as required - Short Point
CD0321Supplying and fixing of PVC mini trunking on surface for light/call bell/fan/2-pin socket outlet/3/5-pin 6A plug point along with all accessories such as changeable internal/external/flat anlges, flat junction,end caps, switch box etc. complete as required- Medium Point
CD0322Supplying and fixing of PVC mini trunking on surface for light/call bell/fan/2-pin socket outlet/3/5-pin 6A plug point along with all accessories such as changeable internal/external/flat anlges, flat junction,end caps, switch box etc. complete as required- Long Point
CD0323Supplying and fixing of PVC mini-trunking on surface for 3/5 pin 6/16 ampere plug point along with all accessories such as changeable internal/external/flt angles, flat junctions, end caps, switch box, etc.
Labour and Material Coefficients (Electrical)- 2013 Page 159
Department of Engineering Services, MoWHS
Coefficient for per point of CD0324
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.11 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.27 day MT4863 PVC Boxes - 4 Module 1 each MT7000 Mini trunking 32x12.5mm 5 m MT7002 Changeable internal/external angle 1 each MT7003 Changeable flat angle 1 each
MT7001 End cap 0.2 each
Coefficient for per point of CD0325
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4863 PVC Boxes - 4 Module 1 each MT7000 Mini trunking 32x12.5mm 8.5 m MT7002 Changeable internal/external angle 1 each MT7003 Changeable flat angle 1 each
MT7001 End cap 0.5 each
CHAPTER 8: BOXES
BX0001 Coefficient for per each of BX0001
Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4905 Wooden boxes - Box 75x75x38mm 1 each BX0002 Coefficient for per each of BX0002
Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4909 Wooden boxes - Box 100x75x38mm 1 each
Supplying & fixing of wooden boxes including painting etc as required - 75x75x38mm
Supplying & fixing of wooden boxes including painting etc as required - 100x75x38mm
CD0324Supplying and fixing of PVC mini-trunking on surface for 3/5 pin 6/16 ampere plug point along with all accessories such as changeable internal/external/flt angles, flat junctions, end caps, switch box, etc. complete as required - Medium Point
CD0325Supplying and fixing of PVC mini-trunking on surface for 3/5 pin 6/16 ampere plug point along with all accessories such as changeable internal/external/flt angles, flat junctions, end caps, switch box, etc. complete as required - Long Point
Labour and Material Coefficients (Electrical)- 2013 Page 160
Department of Engineering Services, MoWHS
BX0003 Coefficient for per each of BX0003
Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4906 Wooden boxes - Box 100x100x38mm 1 each BX0004 Coefficient for per each of BX0004
Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4907 Wooden boxes - Box 150x150x38mm 1 each BX0005 Coefficient for per each of BX0005
Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4908 Wooden boxes - Box 180x150x38mm 1 each BX0006 Coefficient for per each of BX0006
Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4910 Wooden boxes - Box 200x100x38mm 1 each BX0007 Coefficient for per each of BX0007
Code Description Quant Units LB0051 Mason Gd.2 0.05 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.03125 day LB0069 Wireman Gd.2 0.0917 day MT4874 PVC sleev 35mm 4 each MT4911 Wooden boxes - Box 250x200x38mm 1 each
Supplying & fixing of wooden boxes including painting etc as required - 180x150x38mm
Supplying & fixing of wooden boxes including painting etc as required - 200x100x38mm
Supplying & fixing of wooden boxes including painting etc as required - 250x200x38mm
Supplying & fixing of wooden boxes including painting etc as required - 100x100x38mm
Supplying & fixing of wooden boxes including painting etc as required - 150x100x38mm
Labour and Material Coefficients (Electrical)- 2013 Page 161
Department of Engineering Services, MoWHS
BX0008
Coefficient for per each of BX0008
Code Description Quant Units LB0051 Mason Gd.2 0.05 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.03125 day LB0069 Wireman Gd.2 0.0917 day MT4874 PVC sleev 35mm 4 each MT4912 Wooden boxes - Box 300x200x38mm 1 each BX0009
Coefficient for per each of BX0009
Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.04175 day LB0069 Wireman Gd.2 0.1125 day MT4874 PVC sleev 35mm 6 each MT4913 Wooden boxes - Box 450x300x38mm 1 each
BX0020
Coefficient for per each of BX0020
Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4860 PVC Boxes - 1 Module 1 each MT4874 PVC sleev 35mm 4 each
BX0021
Coefficient for per each of BX0021
Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4861 PVC Boxes - 2 Module 1 each MT4874 PVC sleev 35mm 4 each
BX0022
Coefficient for per each of BX0022
Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4862 PVC Boxes - 3 Module 1 each MT4874 PVC sleev 35mm 4 each
Supplying & fixing of wooden boxes including painting etc as required - 300x200x38mm
Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required
Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required
Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required
Supplying & fixing of wooden boxes including painting etc as required - 450x300x38mm
Labour and Material Coefficients (Electrical)- 2013 Page 162
Department of Engineering Services, MoWHS
BX0023
Coefficient for per each of BX0023
Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4863 PVC Boxes - 4 Module 1 each
BX0024
Coefficient for per each of BX0024
Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4864 PVC Boxes - 5 Module 1 each
BX0025
Coefficient for per each of BX0025
Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4865 PVC Boxes - 6 Module 1 each
BX0026
Coefficient for per each of BX0026
Code Description Quant Units LB0051 Mason Gd.2 0.05 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.03125 day LB0069 Wireman Gd.2 0.0917 day MT4874 PVC sleev 35mm 4 each MT4866 PVC Boxes - 7 Module 1 each
BX0027
Coefficient for per each of BX0027
Code Description Quant Units LB0051 Mason Gd.2 0.05 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.03125 day LB0069 Wireman Gd.2 0.0917 day MT4874 PVC sleev 35mm 4 each MT4867 PVC Boxes - 8 Module 1 each
Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required
Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required
Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required
Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required
Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required
Labour and Material Coefficients (Electrical)- 2013 Page 163
Department of Engineering Services, MoWHS
BX0028
Coefficient for per each of BX0028
Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.04175 day LB0069 Wireman Gd.2 0.1125 day MT4874 PVC sleev 35mm 4 each MT4868 PVC Boxes - 9 Module 1 each
BX0029
Coefficient for per each of BX0029
Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4869 PVC Boxes - 10 Module 1 each
BX0050
Coefficient for per each of BX0050
Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT5900 Metal boxes - 1 Module 1 each
BX0051
Coefficient for per each of BX0051
Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT5901 Metal boxes - 2 Module 1 each
BX0052
Coefficient for per each of BX0052
Code Description Quant Units LB0051 Mason Gd.2 0.0833 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.125 day MT4874 PVC sleev 35mm 4 each MT5902 Metal boxes - 3 Module 1 each
Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required
Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required
Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required
Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required
Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required
Labour and Material Coefficients (Electrical)- 2013 Page 164
Department of Engineering Services, MoWHS
BX0053
Coefficient for per each of BX0053
Code Description Quant Units LB0051 Mason Gd.2 0.0833 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.125 day MT4874 PVC sleev 35mm 4 each MT5903 Metal boxes - 4 Module 1 each
BX0054
Coefficient for per each of BX0054
Code Description Quant Units LB0051 Mason Gd.2 0.0833 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.125 day MT4874 PVC sleev 35mm 4 each MT5904 Metal boxes - 5 Module 1 each
BX0055
Coefficient for per each of BX0055
Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0125 day LB0069 Wireman Gd.2 0.1417 day MT4874 PVC sleev 35mm 4 each MT5905 Metal boxes - 6 Module 1 each
BX0056
Coefficient for per each of BX0056
Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0156 day LB0069 Wireman Gd.2 0.1417 day MT4874 PVC sleev 35mm 4 each MT5906 Metal boxes - 7 Module 1 each
BX0057
Coefficient for per each of BX0057
Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0156 day
Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required
Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required
Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required
Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required
Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required
Labour and Material Coefficients (Electrical)- 2013 Page 165
Department of Engineering Services, MoWHS
LB0069 Wireman Gd.2 0.1417 day MT4874 PVC sleev 35mm 4 each MT5907 Metal boxes - 8 Module 1 each
BX0058
Coefficient for per each of BX0058
Code Description Quant Units LB0051 Mason Gd.2 0.0833 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.125 day MT4874 PVC sleev 35mm 4 each MT5908 Metal boxes - 9 Module 1 each
BX0059
Coefficient for per each of BX0059
Code Description Quant Units LB0051 Mason Gd.2 0.0833 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.125 day MT4874 PVC sleev 35mm 4 each MT5909 Metal boxes - 10 Module 1 each
CHAPTER 9: SWITCHES & SOCKETS
SS0001
Coefficient for per each of SS0001
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
SS0002
Coefficient for per each of SS0002
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each
SS0003
Coefficient for per each of SS0003
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5821 Bell push 6A 1 each MT5822 Plate 1-module with frame 1 each
SS0015
Coefficient for per each of SS0015
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day
Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required
Supplying & fixing of 6A switch on existing wooden board including necessary cutting, connections, testing etc. as required. - 6A switch SP 1- way
Supplying & fixing of 6A switch on existing wooden board including necessary cutting, connections, testing etc. as required. - 6A switch SP 2- way
Supplying & fixing of 6A switch on existing wooden board including necessary cutting, connections, testing etc. as required. - bell push 6A
Supplying & fixing of socket/regulator on existing wooden board including necessary cutting, connections, testing etc. as required. - Regulator or Dimmer
Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required
Labour and Material Coefficients (Electrical)- 2013 Page 166
Department of Engineering Services, MoWHS
LB0069 Wireman Gd.2 0.0417 day MT5817 Dimmer / regulator 1 each MT5823 Plate 2-module with frame 1 each
SS0016
Coefficient for per each of SS0016
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5820 RJ 11 telephone socket 1 each MT5822 Plate 1-module with frame 1 each
Supplying & fixing of socket/regulator on existing wooden board including necessary cutting, connections, testing etc. as required. - RJ 11Telephone socket
Labour and Material Coefficients (Electrical)- 2013 Page 167
Department of Engineering Services, MoWHS
SS0017
Coefficient for per each of SS0017
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5818 TV coaxial socket 1 each MT5822 Plate 1-module with frame 1 each
SS0030
Coefficient for per each of SS0030
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5808 2-pin 6A socket outlet 1 each MT5822 Plate 1-module with frame 1 each
SS0031
Coefficient for per each of SS0031
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5816 5-pin universal socket outlet 1 each MT5823 Plate 2-module with frame 1 each
SS0032
Coefficient for per each of SS0032
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5807 16A fuse unit 1 each MT5822 Plate 1-module with frame 1 each
SS0045
Coefficient for per each of SS0045
Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5806 16A switch SP 1 or 2-way 1 each MT5822 Plate 1-module with frame 1 each
Supplying & fixing of socket/regulator on existing wooden board including necessary cutting, connections, testing etc. as required. - TV coaxial socket
Supplying & fixing of socket outlet on existing wooden board including necessary cutting, connections, testing etc. as required. - 2 pin 6A socket outlet
Supplying & fixing of socket outlet on existing wooden board including necessary cutting, connections, testing etc. as required. - 5 pin universal socket outlet
Supplying & fixing of socket outlet on existing wooden board including necessary cutting, connections, testing etc. as required. - 16 ampere fuse unit
Supplying & fixing of switch on existing wooden board/round block/junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. - 16A switch SP 1 or 2 way
Labour and Material Coefficients (Electrical)- 2013 Page 168
Department of Engineering Services, MoWHS
SS0046
Coefficient for per each of SS0046
Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5814 5/6 pin, 6/16A socket outlet, shuttered 1 each MT5825 Plate 4-module with frame 1 each
SS0047
Coefficient for per each of SS0047
Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5895 Ceiling Rose, 2 plate (PVC) 6A 1 each
SS0060
Coefficient for per each of SS0060
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
SS0061
Coefficient for per each of SS0061
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each
SS0062
Coefficient for per each of SS0062
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5821 Bell push 6A 1 each MT5822 Plate 1-module with frame 1 each
SS0075
Coefficient for per each of SS0075
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5817 Dimmer / regulator 1 each MT5823 Plate 2-module with frame 1 each
Supplying & fixing of socket on existing wooden board/round block/junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. - 5/6 pin, 6/16 ampere socket outlet, shuttered
Supplying & fixing of ceiling rose on existing wooden board/round block/junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. -Ceiling rose, 2 plate (PVC) 6A
Supplying & fixing of 6A switch on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - 6A switch SP 1 way
Supplying & fixing of 6A switch on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - 6A switch SP 2 way
Supplying & fixing of 6A switch on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - bell push 6A
Supplying & fixing of socket/regulator on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - Regulator or Dimmer
Labour and Material Coefficients (Electrical)- 2013 Page 169
Department of Engineering Services, MoWHS
SS0076
Coefficient for per each of SS0076
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5820 RJ 11 telephone socket 1 each MT5822 Plate 1-module with frame 1 each
SS0077
Coefficient for per each of SS0077
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5818 TV coaxial socket 1 each MT5822 Plate 1-module with frame 1 each
SS0090
Coefficient for per each of SS0090
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5808 2-pin 6A socket outlet 1 each MT5822 Plate 1-module with frame 1 each
SS0091
Coefficient for per each of SS0091
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5816 5-pin universal socket outlet 1 each MT5823 Plate 2-module with frame 1 each
SS0092
Coefficient for per each of SS0092
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5807 16A fuse unit 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per each of SS0105
Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5806 16A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each
16A switch SP 2 way SS0105
Supplying & fixing of socket/regulator on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - RJ 11 Telephone socket
Supplying & fixing of socket/regulator on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - TV coaxial socket
Supplying & fixing of socket outlet on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - 2- pin 6A socket outlet
Supplying & fixing of socket outlet on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - 5 pin universal socket outlet
Supplying & fixing of socket outlet on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - 16A fuse unit
Supplying & fixing of switch on existing metal box with fibre sheet cover (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connection testing etc. as required-
Labour and Material Coefficients (Electrical)- 2013 Page 170
Department of Engineering Services, MoWHS
Coefficient for per each of SS0106
Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5814 5/6 pin, 6/16A socket outlet, shuttered 1 each MT5825 Plate 4-module with frame 1 each
Coefficient for per each of SS0107
Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5895 Ceiling Rose, 2 plate (PVC) 6A 1 each
SS0120
Coefficient for per each of SS0120
Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
SS0121
Coefficient for per each of SS0121
Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each
SS0122
Coefficient for per each of SS0122
Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5821 Bell push 6A 1 each MT5822 Plate 1-module with frame 1 each
SS0135
Coefficient for per each of SS0135
Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5817 Dimmer / regulator 1 each MT5823 Plate 2-module with frame 1 each
Ceiling rose, 2 plate (PVC) 6A SS0107
Supplying & fixing of 6A switch on existing PVC/metal / moulded tough surface box (recessed or surface) including necessary cutting, connections, testing etc. as required. - 6A switch SP 1 way
Supplying & fixing of 6A switch on existing PVC/metal / moulded tough surface box (recessed or surface) including necessary cutting, connections, testing etc. as required. - 6A switch SP 2 way
Supplying & fixing of 6A switch on existing PVC/metal / moulded tough surface box (recessed or surface) including necessary cutting, connections, testing etc. as required. - bell push 6A
Supplying & fixing of socket/regulator on existing PVC/metal / moulded tough surface box (recessed or surface) including necessary cutting, connections, testing etc. as required. - Regulator or Dimmer
Supplying & fixing of socket on existing metal box with fibre sheet cover (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connection testing etc. as required. - 5/6 pin 6/16A socket outlet, shuttered
SS0106
Supplying & fixing of ceiling rose on existing metal box with fibre sheet cover (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. -
Labour and Material Coefficients (Electrical)- 2013 Page 171
Department of Engineering Services, MoWHS
SS0136
Coefficient for per each of SS0136
Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5820 RJ 11 telephone Socket 1 each MT5822 Plate 1-module with frame 1 each
SS0137
Coefficient for per each of SS0137
Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5818 TV coaxial socket 1 each MT5822 Plate 1-module with frame 1 each
SS0150
Coefficient for per each of SS0150
Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5808 2-pin 6A socket outlet 1 each MT5822 Plate 1-module with frame 1 each
SS0151
Coefficient for per each of SS0151
Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5816 5-pin universal socket outlet 1 each MT5823 Plate 2-module with frame 1 each
SS0152
Coefficient for per each of SS0152
Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5807 16A fuse unit 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per each of SS0165
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5806 16A switch SP 1 or 2-way 1 each MT5822 Plate 1-module with frame 1 each
Supplying & fixing of switch on existing metal box with fibre sheet cover (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. - 16A switch SP 2 way
SS0165
Supplying & fixing of socket/regulator on existing PVC/metal / moulded tough surface box (recessed or surface) including necessary cutting, connections, testing etc. as required. - RJ 11 telephone socket
Supplying & fixing of socket/regulator on existing PVC/metal / moulded tough surface box (recessed or surface) including necessary cutting, connections, testing etc. as required. - TV coaxial socket
Supplying & fixing of socket outlet on existing PVC/metal / moulded tough surface box (recessed or surface)including necessary cutting, connections, testing etc. as required. - 2 pin 6A socket outlet
Supplying & fixing of socket outlet on existing PVC/metal / moulded tough surface box (recessed or surface) including necessary cutting, connections, testing etc. as required. - 5 pin universal socket outlet
Supplying & fixing of socket outlet on existing PVC/metal / moulded tough surface box (recessed or surface) including necessary cutting, connections, testing etc. as required. - 16A fuse unit
Labour and Material Coefficients (Electrical)- 2013 Page 172
Department of Engineering Services, MoWHS
Coefficient for per each of SS0166
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5814 5/6 pin, 6/16A socket outlet, shuttered 1 each MT5825 Plate 4-module with frame 1 each
Coefficient for per each of SS0167
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5895 Ceiling Rose, 2 plate (PVC) 6A 1 each
Coefficient for per each of SS0175
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5824 Plate 3-module with frame 1 each
Coefficient for per each of SS0176
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5816 5-pin universal socket outlet 1 each MT5823 Plate 2-module with frame 1 each
Coefficient for per each of SS0177
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5819 RJ 45 computer socket 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per each of SS0185
Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5804 16A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each
Supplying & fixing of switch on existing PVC /metal/ moulded tough surface box, metal box (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. - 16A switch SP 1 way
SS0185
Supplying & fixing of socket outlet on existing PVC /metal/ moulded tough surface box/ metal box (recessed or surface) including necessary cutting, connections, testing etc. as required. - 5 pin universal socket outlet
SS0176
Supplying & fixing of socket outlet on existing PVC /metal/ moulded tough surface box/ metal box (recessed or surface) including necessary cutting, connections, testing etc. as required. - RJ 45 compter socket
SS0177
Supplying & fixing of Ceiling rose on existing metal box with fibre sheet cover (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. -Ceiling rose, 2 plate(PVC) 6A
SS0167
Supplying & fixing of socket outlet on existing PVC /metal/ moulded tough surface box/ metal box (recessed or surface) including necessary cutting, connections, testing etc. as required. - 3 pin, 6A socket outlet, shuttered
SS0175
Supplying & fixing of socket on existing metal box with fibre sheet cover (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. - 5/6 pin 6/16A socket outlet, shuttered
SS0166
Labour and Material Coefficients (Electrical)- 2013 Page 173
Department of Engineering Services, MoWHS
Coefficient for per each of SS0186
Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5806 16A switch SP 2 way 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per each of SS0187
Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5814 5/6 pin, 6/16A socket outlet, shuttered 1 each MT5825 Plate 4-module with frame 1 each
Coefficient for per each of SS0195
Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5810 3-pin, 16A socket outlet, shuttered 1 each MT5822 Plate 1-module with frame 1 each
Coefficient for per each of SS0205
Code Description Quant Units LB0056 Wireman Gd.1 0.0555 day LB0069 Wireman Gd.2 0.0555 day MT5811 3-pin, 6A switch/socket combined, shuttered 1 each MT5824 Plate 3-module with frame 1 each
Coefficient for per each of SS0210
Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0069 Wireman Gd.2 0.0625 day MT5813 3-pin, 16A switch/socket combined, Shuttered 1 each MT5825 Plate 4-module with frame 1 each
Supplying & fixing of 6 ampere switch/socket on existing PVC /metal/ moulded tough surface box metal box (recessed or surface) with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - 3 pin 6 ampere switch/socket combined, shuttered
SS0205
Supplying & fixing of switch/socket on existing PVC /metal/ moulded tough surface box metal box (recessed or surface) with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - 3 pin, 16A switch/socket combined, shuttered
SS0210
Supplying & fixing of socket on existing PVC /metal/ moulded tough surface box, metal box (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. - 5/6 pin, 6/16A socket outlet, shuttered
SS0187
Supplying & fixing of 16A switch on existing PVC /metal/ moulded tough surface box metal box (recessed or surface) with fibre sheet cover (recessed or surface) including necessary cutting, connection testing etc. as required- 3 pin 16 ampere socket outlet
SS0195
Supplying & fixing of switch on existing PVC /metal/ moulded tough surface box, metal box (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. - 16A switch SP 2way
SS0186
Labour and Material Coefficients (Electrical)- 2013 Page 174
Department of Engineering Services, MoWHS
Coefficient for per each of SS0220
Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0069 Wireman Gd.2 0.0625 day MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5825 Plate 4-module with frame 1 each
Coefficient for per each of SS0221
Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0069 Wireman Gd.2 0.0625 day MT5890 Holders & Plugs - Batten holder (heavy duty, brass) 1 each
Coefficient for per each of SS0230
Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0069 Wireman Gd.2 0.0625 day MT5891 Holders & Plugs - Plain pendant holder (bakelite) 1 each
Coefficient for per each of SS0231
Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0069 Wireman Gd.2 0.0625 day MT5891 Holders & Plugs - Plain pendant holder (bakelite) 1 each
Coefficient for per each of SS0232
Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0069 Wireman Gd.2 0.0625 day MT5892 Holders & Plugs - Angle holder (heavy duty) 1 each
CHAPTER 10: INDOOR LUMINIARIES (Supply)
Coefficient for per each of IL0001
Code Description Quant Units MT5720 Globe dia 150mm, 1x60W 1 each
Supplying & fixing on existing PVC/ wooden /metal/ moulded tough surface box with fibre sheet cover, round block, junction box (recessed or surface) including necessary cutting, connections, testing etc.as required. - Angle holder (heavy duty, brass plunger)
SS0232
Supplying & fixing on existing PVC/ wooden /metal/ moulded tough surface box with fibre sheet cover, round block, junction box (recessed or surface) including necessary cutting, connections, testing etc. as required. - Plain pendant holder with alumetic 2 core PVC wire cord grip
SS0230
Supplying & fixing on existing PVC/ wooden /metal/ moulded tough surface box with fibre sheet cover, round block, junction box (recessed or surface) including necessary cutting, connection testing etc.as required. - Plain pendant brass holder (heavy duty with twin twisted flexible wire)
SS0231
Supplying & fixing of switch/socket on existing PVC/ wooden /metal/ moulded tough surface box with fibre sheet cover, round block, junction box (recessed or surface) including necessary cutting, connections, testing etc. as required. - 5/6 pin, switch / socket combined, shuttered
SS0220
Supplying & fixing on existing PVC/ wooden /metal/ moulded tough surface box with fibre sheet cover, round block, junction box (recessed or surface) including necessary cutting, connections testing etc. as required. - Batten holder (heavy duty, brass plunger)
SS0221
Supplying of prewired indoor surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. butwithout lamp - Globe dia 150, projection 215mm, finish-painted
IL0001
Labour and Material Coefficients (Electrical)- 2013 Page 175
Department of Engineering Services, MoWHS
Coefficient for per each of IL0002
Code Description Quant Units MT5721 Globe dia 200mm, 1x60W 1 each
Coefficient for per each of IL0003
Code Description Quant Units MT5722 Globe dia 250mm, 1x60W 1 each
Coefficient for per each of IL0004
Code Description Quant Units MT5723 Square louvered, 1x60W 1 each
Coefficient for per each of IL0005
Code Description Quant Units MT5724 Special drumlite, dia 175mm milky, 1x60W 1 each
Coefficient for per each of IL0006
Code Description Quant Units MT5725 Special drumlite dia 225mm milky, 1x60W 1 each
Coefficient for per each of IL0020
Code Description Quant Units MT5726 Spot light 235mm, reflector dia 130mm, 1x60W 1 each
Coefficient for per each of IL0021
Code Description Quant Units MT5727 Spot light 245mm, reflector dia 100mm, 1x60W 1 each
Supplying of prewired indoor surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. but without lamp - Square louvered, projection 115mm, length or width 240mm,finish-painted
Supplying of prewired indoor surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. but without lamp - Globe dia 200, projection 265mm, finish-painted
IL0002
Supplying of prewired indoor surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. but without lamp - Globe dia 250, projection 315mm, finish-painted
IL0003
IL0004
Supplying of prewired indoor surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. but without lamp - Special drumlite dia 175, projection 115mm, finish-painted
IL0005
Supplying of prewired indoor surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. but without lamp - Special drumlite dia 225, milky, projection 115mm, finish-painted
IL0006
Supplying of prewired indoor spots and clamps surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. but without lamp - Spot light fixtures finish-painted, reflector dia 130mm, projection 235mm
IL0020
Supplying of prewired indoor spots and clamps surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. but without lamp - Spot light fixtures, finish-painted, reflector dia 100mm, projection 245mm
IL0021
Labour and Material Coefficients (Electrical)- 2013 Page 176
Department of Engineering Services, MoWHS
Coefficient for per each of IL0022
Code Description Quant Units MT5728 Clamp light 225mm, dia 110mm, 1x60W 1 each
Coefficient for per each of IL0035
Code Description Quant Units MT5729 Clamp light 160mm, 100W 1 each
Coefficient for per each of IL0036
Code Description Quant Units MT5730 Rail light 225mm, 2x60W (R) 1 each
Coefficient for per each of IL0037
Code Description Quant Units MT5731 Rail light 160mm, 2x100W (R) 1 each
Coefficient for per each of IL0050
Code Description Quant Units MT5732 Rail light 225mm, 3x60W (R) 1 each
Coefficient for per each of IL0051
Code Description Quant Units MT5733 Rail light 160mm, 3x100W (R) 1 each
Coefficient for per each of IL0052
Code Description Quant Units MT5734 Wall bracket 225mm, 1x60W 1 each
Coefficient for per each of IL0065
Code Description Quant Units MT5735 Wall bracket 230mm, 1x60W 1 each
Supplying of prewired indoor spots and clamps surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. but without lamp-Clamp light fixtures, reflector dia 110mm, projection 225mm, finish-painted
IL0022
Supplying of prewired indoor clamps and rails on surface / ceiling mounted luminiaries suitable for reflector lamp for maximum wattage upto 60/100 watts complete with all accessories such as base,holder, reflector etc. but without lamp - Clamp light projection 160mm, finish-painted, suitable for reflector lamp, 100W
IL0035
Supplying of prewired indoor clamps and rails on surface / ceiling mounted luminiaries suitable for reflector lamp for maximum wattage upto 60/100 watts complete with all accessories such as base, holder, reflector etc. but without lamp - Rail light fixtures for 2x60W (R), reflector lamp of projection 225mm, rail lenght 600mm
IL0036
Supplying of prewired indoor rails and wall brackets on surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base,
Supplying of prewired indoor clamps and rails on surface / ceiling mounted luminiaries suitable for reflector lamp for maximum wattage upto 60/100 watts complete with all accessories such as base, holder, reflector etc. but without lamp - Rail light lamp of projection 160mm, rail length 600mm, 2x100W (R)
IL0037
Supplying of prewired indoor rails and wall brackets on surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, reflector, rails, glass globe, etc. but without lamp - Rail lighting projection 225mm, finish painted, suitable for reflector lamp, 3x60W (R)
IL0050
holder, reflector, rails, glass globe, etc. but without lamp - Rail lighting fixtures of projection 160mm for 3x100W (R) reflector lamp length of rail 600mm
IL0051
Supplying of prewired indoor rails and wall brackets on surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, reflector, rails, glass globe, etc. but without lamp - Wall bracket projection 225mm, height 240mm finish painted, glass frosted, 1x60W
IL0052
Supplying of prewired indoor rails and wall brackets on surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, reflector, rails, glass globe, etc. but without lamp - Wall bracket upward projection 230mm, height 225mm finish-painted globe 360/400mm dia.. glass milky/ frosted, 1x60W
IL0065
Labour and Material Coefficients (Electrical)- 2013 Page 177
Department of Engineering Services, MoWHS
Coefficient for per each of IL0066
Code Description Quant Units MT5736 Wall bracket 160mm, 1x60W 1 each
Coefficient for per each of IL0067
Code Description Quant Units MT5737 Wall bracket 185mm, 1x60W 1 each
Coefficient for per each of IL0080
Code Description Quant Units MT5738 Double wall bracket 200mm, 2x60W 1 each
Coefficient for per each of IL0081
Code Description Quant Units MT5739 Double wall bracket 160mm, 2x60W 1 each
Coefficient for per each of IL0082
Code Description Quant Units MT5740 Single swivel wall bracket 375mm, 1x60W 1 each
Coefficient for per each of IL0095
Code Description Quant Units MT5741 Double mirror light 610mm, 2x60W 1 each
Coefficient for per each of IL0096
Code Description Quant Units MT5742 Double mirror light 460mm, 2x60W 1 each
Coefficient for per each of IL0097
Code Description Quant Units MT5743 Single picture light 200mm, 1x60W 1 each
Supplying of prewired indoor rails and wall brackets on surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, reflector, rails, glass globe, etc. but without lamp - Wall bracket down lighter projection 160mm, height 135mm width or base dia 320mm finish-painted, glass frosted, 1x60W
IL0066
Supplying of prewired indoor rails and wall brackets on surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, reflector, rails, glass globe, etc. but without lamp - Wall bracket down lighter, projection 185mm, height 100mm finish painted, 1x60W
IL0067
without lamp - Double wall bracket upward projection 200mm, height 275mm finish-painted globe 360/400mm dia.. glass milky/ frosted, 2x60W
Supplying of prewired indoor wall mounted wall brackets luminiaries suitable for GLS lamp for wattage upto 2x60/1x60 watts complete with all accessories such as base, holder, glass globe, etc. but IL0080
Supplying of prewired indoor wall mounted wall brackets luminiaries suitable for GLS lamp for wattage upto 2x60/1x60 watts complete with all accessories such as base, holder, glass globe, etc. but withoutlamp - Double wall bracket down lighter projection 160mm, height 135mm width or base dia 320mm finish-painted, glass frosted, 2x60W
IL0081
Supplying of prewired indoor wall mounted wall brackets luminiaries suitable for GLS lamp for wattage upto 2x60/1x60 watts complete with all accessories such as base, holder, glass globe, etc. but without lamp - Single swivel wall bracket down lighter, projection 375mm, height 250mm finish painted with switch, 1x60W
IL0082
Supplying of prewired indoor mirror/picture light luminiaries suitable for GLS lamp for wattage upto 2x60/1x60 watts complete with all accessories such as base, holder, glass globe, etc. but without lamp-Double mirror light fixtures downward projection 100mm, height 90mm, lenght 610mm, finish-painted, glass milky/ frosted, 2x60W
IL0095
Supplying of prewired indoor mirror/picture light luminiaries suitable for GLS lamp for wattage upto 2x60/1x60 watts complete with all accessories such as base, holder, glass globe, etc. but without lamp - Double mirror light fixtures downward projection 100mm, height 90mm, lenght 460mm, finish-painted, glass milky/ frosted, 2x60W
IL0096
Supplying of prewired indoor mirror/picture light luminiaries suitable for GLS lamp for wattage upto 2x60/1x60 watts complete with all accessories such as base, holder, glass globe, etc. but without lamp - Single picture down lighter, projection 200mm, height 100mm, length 360mm, finish painted, 1x60W
IL0097
Labour and Material Coefficients (Electrical)- 2013 Page 178
Department of Engineering Services, MoWHS
Coefficient for per each of IL0110
Code Description Quant Units MT5744 Pendant down lighter 215mm, 1x60W 1 each
Coefficient for per each of IL0111
Code Description Quant Units MT5745 Pendant lantern type 460mm, 1x60W 1 each
Coefficient for per each of IL0112
Code Description Quant Units MT5746 Pendant 460mm, 3x60W 1 each
Coefficient for per each of IL0125
Code Description Quant Units MT5747 Recessed down lighter square 170-190mm, 1x100W 1 each
Coefficient for per each of IL0126
Code Description Quant Units MT5748 Recessed down lighter, round 180mm, 1x100W 1 each
Coefficient for per each of IL0127
Code Description Quant Units MT5749 Recessed down lighter, round 165mm, 1x60W (R) 1 each
Coefficient for per each of IL0140
Code Description Quant Units MT5750 Semi recessed down lighter square 170-200mm, 1x100W 1 each
Coefficient for per each of IL0141
Code Description Quant Units MT5751 Semi recessed down lighter, round 90-95mm, 1x100W 1 each
Supplying of prewired indoor pendant lighting luminiaries suitable for GLS lamp 1x60 watts complete with all accessories such as base, holder, glass globe, reflector, suspender, etc etc. but without lamp - Pendant down lighter height 215mm, 205mm dia, finish-painted, 1x60W
IL0110
Supplying of prewired indoor pendant lighting luminiaries suitable for GLS lamp 1x60 watts complete with all accessories such as base, holder, glass globe, reflector, suspender, etc etc. but without lamp - Lantern type, height 460mm, 325mm dia, finish-painted, 1x60W
IL0111
Supplying of prewired indoor pendant lighting luminiaries suitable for GLS lamp 1x60 watts complete with all accessories such as base, holder, glass globe, reflector, suspender, etc etc. but without lamp - Three lighting fixture, height 460mm, 430mm dia finish painted, 3x60W
IL0112
Supplying of prewired indoor recessed down light luminiaries suitable for GLS/reflector lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass globe, reflector, fixingclip, etc etc. but without lamp - Recessed down lighter square width 170-195, cut out 140-165mm, depth 200mm, finish-painted, 1x100W
IL0125
Supplying of prewired indoor recessed down light luminiaries suitable for GLS/reflector lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass globe, reflector, fixing clip, etc etc. but without lamp - Recessed down lighter projection 55mm, cut out 155mm, depth 175mm, 180mm dia, finish-painted, 1x100W
IL0126
Supplying of prewired indoor recessed down light luminiaries suitable for GLS/reflector lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass globe, reflector, fixing clip, etc etc. but without lamp - Recessed down lighter projection 45mm, cut out 110mm, depth 75mm, 165mm dia, finish-painted, 1x60W
IL0127
Supplying of prewired indoor semi-recessed down light luminiaries suitable for GLS/reflector lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass globe, reflector, fixing clip, etc etc. but without lamp - Semi recessed down lighter square width 170-200, cut out 135-160mm, depth 125-135mm, finish-painted, 1x100W
IL0140
Supplying of prewired indoor semi-recessed down light luminiaries suitable for GLS/reflector lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass globe, reflector, fixing clip, etc etc. but without lamp - Semi recessed down lighter projection 90-95mm, cut out 135-160mm, depth 125-135mm, 170-200mm dia, finish-painted, 1x100W
IL0141
Labour and Material Coefficients (Electrical)- 2013 Page 179
Department of Engineering Services, MoWHS
Coefficient for per each of IL0142
Code Description Quant Units MT5752 Semi recessed down lighter, side entry 205mm, 1x60W (R) 1 each
Coefficient for per each of IL0155
Code Description Quant Units
MT5945Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Strip Rail, 18/20 W, LPF 1 each
Coefficient for per each of IL0156
Code Description Quant Units
MT5946Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Decorative, box type 18/20 W, LPF 1 each
Coefficient for per each of IL0157
Code Description Quant Units
MT5947Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Mounting channel, 18/20 W, LPF 1 each
Coefficient for per each of IL0158
Code Description Quant Units
MT5948Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Strip Rail, 36/40 W, LPF 1 each
Coefficient for per each of IL0159
Code Description Quant Units
MT5949Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Decorative, box type 36/40 W, LPF 1 each
Coefficient for per each of IL0160
Code Description Quant Units
MT5950Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Mounting channel, 36/40 W, LPF 1 each
Coefficient for per each of IL0170
Code Description Quant Units
MT5951Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Mounting box, 1x36/40 W, HPF 1 each
Supplying of prewired indoor semi-recessed down light luminiaries suitable for GLS/reflector lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass globe, reflector, fixing clip, etc etc. but without lamp - Semi recessed down lighter side entry, cut out 185mm, depth 130mm, 205mm dia, finish-painted, 1x60W
IL0142
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, LPF suitable for wall and ceiling - Strip Rail 18/20 watt
IL0155
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, LPF suitable for wall and ceiling - Decorative box type 18/20 watt
IL0156
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, LPF suitable for wall and ceiling - Mounting channel 18/20 watt
IL0157
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, LPF suitable for wall and ceiling - Strip Rail 36/40 watt
IL0158
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, LPF suitable for wall and ceiling - Decorative box type 36/40 watt
IL0159
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, LPF suitable for wall and ceiling - Mounting channel 36/40 watt
IL0160
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for wall and ceiling directly or pendant - Mounting box 1x36/40 watt
IL0170
Labour and Material Coefficients (Electrical)- 2013 Page 180
Department of Engineering Services, MoWHS
Coefficient for per each of IL0171
Code Description Quant Units
MT5952Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Mounting box, 2x36/40 W, HPF 1 each
Coefficient for per each of IL0172
Code Description Quant Units
MT5953Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Industrial box, 1x36/40 W, HPF 1 each
Coefficient for per each of IL0173
Code Description Quant Units
MT5970Indoor fluorescent lamp luminiaries, steel rail, Industrial box - Vitreous enamel reflector, 1x36/40 W, HPF 1 each
Coefficient for per each of IL0174
Code Description Quant Units
MT5971Indoor fluorescent lamp luminiaries, steel rail, Industrial box - Stove enamel reflector, 2x36/40 W, HPF 1 each
Coefficient for per each of IL0175
Code Description Quant Units
MT5973Indoor fluorescent lamp luminiaries, steel rail, Industrial box - Vitreous enamel reflector, 2x36/40 W, HPF 1 each
Coefficient for per each of IL0185
Code Description Quant Units
MT5990
Indoor decorative fluorescent lamp luminiaries, steel rail, surface mounting box - Polysterene structured louvere and reflector, 2x36/40 W, HPF 1 each
Coefficient for per each of IL0186
Code Description Quant Units
MT5991Indoor decorative fluorescent lamp luminiaries, steel rail, surface mounting box - Metal louvere and reflector, 2x36/40 W, HPF 1 each
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for wall and ceiling directly or pendant - Mounting box 2x36/40 watt
IL0171
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for wall and ceiling directly or pendant - Industrial box 1x36/40 watt
IL0172
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for wall and ceiling directly or pendant - Industrial box type with vitreous enamel reflector 1x36/40 watt
IL0173
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for wall and ceiling directly or pendant - Industrial box type with vitreous enamel reflector 2x36/40 watt
IL0174
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for wall and ceiling directly or pendant - Industrial box type with stove enamel reflector 2x36/40 watt
IL0175
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface or pendant mounting - Mounting box type with polysterene structured louvere and reflector 2x36/40 watt
IL0185
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface or pendant mounting - Mounting box type with metalled louvere and reflector 2x36/40 watt
IL0186
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface or pendant mounting - Mounting box type with opal acrylic difuser and reflector 2x36/40 watt
IL0187
Labour and Material Coefficients (Electrical)- 2013 Page 181
Department of Engineering Services, MoWHS
Code Description Quant Units
MT5992Indoor decorative fluorescent lamp luminiaries, steel rail, surface mounting box - Opal acrylic diffuser and reflector, 2x36/40 W, HPF 1 each
Coefficient for per each of IL0188
Code Description Quant Units
MT5994Indoor decorative fluorescent lamp luminiaries, steel rail, surface mounting box - Prismatic louvere and reflector, 2x36/40 W, HPF 1 each
Coefficient for per each of IL0189
Code Description Quant Units
MT5995Indoor decorative fluorescent lamp luminiaries, steel rail, surface mounting box - Opal acrylic diffuser, 2x36/40 W, HPF 1 each
Coefficient for per each of IL0190
Code Description Quant Units
MT5996Indoor decorative fluorescent lamp luminiaries, steel rail, surface mounting box - Opal acrylic diffuser and reflector, 2x18/20 W, HPF 1 each
Coefficient for per each of IL0200
Code Description Quant Units
MT6020Indoor decorative fluorescent lamp luminiaries, steel rail, recessed, Mounting box - Prismatic louvere and reflector, 2x36/40 W, HPF 1 each
Coefficient for per each of IL0201
Code Description Quant Units
MT6021Indoor decorative fluorescent lamp luminiaries, steel rail, recessed, Mounting box - Opal acrylic diffuser, 2x36/40 W, HPF 1 each
Coefficient for per each of IL0202
Code Description Quant Units
MT6022Indoor decorative fluorescent lamp luminiaries, steel rail, recessed, Mounting box - Structured louvere and reflector, 2x36/40 W, HPF 1 each
Coefficient for per each of IL0215
Code Description Quant Units
MT6040Indoor decorative fluorescent lamp luminiaries, steel rail, surface/recessed, Mounting box - Prismatic louvere and reflector, 4x18/20 W, HPF 1 each
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface or pendant mounting - Mounting box type with prismatic louvere and reflector 2x36/40 watt
IL0188
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface or pendant mounting - Mounting box type with opal acrylic difuser 1x36/40 watt
IL0189
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface or pendant mounting - Mounting box type with opal acrylic difuser and reflector 2x18/20 watt
IL0190
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for recessed mounting - Mounting box type with prismatic louvere and reflector 2x36/40 watt
IL0200
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for recessed mounting - Mounting box type with opal acrylic difuser 1x36/40 watt
IL0201
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for recessed mounting - Mounting box type with structured louvere and reflector 2x36/40 watt
IL0202
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface/recessed mounting - Mounting box type with prismatic louvere and reflector 4x18/20 watt
IL0215
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface/recessed mounting - Mounting box type with opal acrylic difuser 4x18/20 watt
IL0216
Labour and Material Coefficients (Electrical)- 2013 Page 182
Department of Engineering Services, MoWHS
Coefficient for per each of IL0216
Code Description Quant Units
MT6041
Indoor decorative fluorescent lamp luminiaries, steel rail, surface/recessed, Mounting box - Opal acrylic diffuser, 4x18/20 W, HPF 1 each
Coefficient for per each of IL0217
Code Description Quant Units
MT6042Indoor decorative fluorescent lamp luminiaries, steel rail, surface/recessed, Mounting box - Structured louvere and reflector, 4x18/20 W, HPF 1 each
Coefficient for per each of IL0230
Code Description Quant Units
MT6043Indoor decorative fluorescent lamp luminiaries, steel rail, surface/recessed, Mounting box - Mirror Optic louvere and reflector, 2x18/20 W, HPF 1 each
Coefficient for per each of IL0231
Code Description Quant Units
MT6044Indoor decorative fluorescent lamp luminiaries, steel rail, surface/recessed, Mounting box - Mirror optic louvere, 2x36/40 W, HPF 1 each
Coefficient for per each of IL0232
Code Description Quant Units
MT6045Indoor decorative fluorescent lamp luminiaries, steel rail, surface/recessed, Mounting box - Wide spread mirror optic and reflector, 2x36/40 W, HPF 1 each
IL0245
Coefficient for per each of IL0245
Code Description Quant Units MT6190 Call bell 250 volt A.C - Gong bell assembly 1 each
IL0246
Coefficient for per each of IL0246
Code Description Quant Units MT6191 Call bell 250 volt A.C - Buzzer bell assembly 1 each
IL0247
Coefficient for per each of IL0247
Code Description Quant Units MT6192 Call bell 250 volt A.C - Musical bell assembly 1 each
Coefficient for per each of IL0260
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface/recessed mounting - Mounting box type with structured louvere and reflector 4x18/20 watt
IL0217
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface/recessed mounting - Mounting box with mirror optics louvere and reflector 2x18/20 watt
IL0230
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface/recessed mounting - Mounting box with mirror optics louvere 2x36/40 watt
IL0231
Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface/recessed mounting - Mounting box with side spread mirror optics with reflector 2x36/40 watt
IL0232
Supplying of prewired call bell 250 volt A.C with base, terminal block and all accessories complete - Gong bell assembly
Supplying of prewired call bell 250 volt A.C with base, terminal block and all accessories complete - Buzzer bell assembly
Supplying of prewired call bell 250 volt A.C with base, terminal block and all accessories complete - Musical bell assembly
Supplying of 250 volt A.C prewired lighting tracks with all accessories such as current supply end assembly, right angle joint horizontal/vertical, coupler assembly, cross/tee joint, conical visor and track lighting luminiare 1 No. etc. suitable for reflector lamp 60 watt in museum or decorated shops complete - 0.5m light track
IL0260
Labour and Material Coefficients (Electrical)- 2013 Page 183
Department of Engineering Services, MoWHS
Code Description Quant Units MT6205 Lighting track 250 volt A.C, for 60 W reflector lamp for museum or decorated 1 each
Coefficient for per each of IL0261
Code Description Quant Units MT6206 Lighting track 250 volt A.C, for 60 W reflector lamp for museum or decorated 1 each
Coefficient for per each of IL0262
Code Description Quant Units MT6207 Lighting track 250 volt A.C, for 60 W reflector lamp for museum or decorated 1 each
CHAPTER 11: OUTDOOR LUMINIARIES (Supply)
Coefficient for per each of OL0001
Code Description Quant Units MT5753 Wall bracket louvered 275mm, 1x60/100W 1 each
Coefficient for per each of OL0002
Code Description Quant Units MT5755 Post top dia 325-380mm, 1x60/100W 1 each
Coefficient for per each of OL0015
Code Description Quant Units MT5754 Bulk head die cast aluminium body, weather proof gasket, wire guard, 1x60/1 1 each
Coefficient for per each of OL0025
Code Description Quant Units MT6060 Street Lighting - 1x36/40 W, HPF 1 each
Coefficient for per each of OL0026
Code Description Quant Units MT6061 Street Lighting - 2x36/40 W, HPF 1 each
Coefficient for per each of OL0027
Supplying of 250 volt A.C prewired lighting tracks with all accessories such as current supply end assembly, right angle joint horizontal/vertical, coupler assembly, cross/tee joint, conical visor and track lighting luminiare 1 No. etc. suitable for reflector lamp 60 watt in museum or decorated shops complete - 2m light track
IL0262
Supplying of 250 volt A.C prewired lighting tracks with all accessories such as current supply end assembly, right angle joint horizontal/vertical, coupler assembly, cross/tee joint, conical visor and track lighting luminiare 1 No. etc. suitable for reflector lamp 60 watt in museum or decorated shops complete - 1m light track
IL0261
Supplying of prewired outdoor lighting luminiaries suitable for GLS lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass, reflector, louvered, etc but without lamp - Wall bracket louvered projection 275mm, height 270mm, finish-painted, 1x60/100W
OL0001
Supplying of prewired outdoor lighting luminiaries suitable for GLS lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass, reflector, louvered, etc. but without lamp - Post top garden light dia 325-380mm, height 340-400mm, finish-painted, 1x60/100W
OL0002
Supplying of prewired outdoor bulk head fittings luminiaries having die cast aluminium body, prismatic heat resistant glass cover held in the weather proof gasket, MS galvanised wire guard, etc. Suitablefor GLS lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass, reflector, louvered, etc.complete but without lamp - Projection 100mm, height 220mm, width 125mm, finish-painted, 1x60/100W
OL0015
Supplying of prewired street lighting fluoresent lamp luminiaries housing of CRCA sheet steel rail, end (with lamp holders, copper wound ballast, starter, starter holder, terminal block etc.butwithout lamp, HPF suitable for street or outdoor lighting - 1x36/40 watt
OL0025
Supplying of prewired street lighting fluoresent lamp luminiaries housing of CRCA sheet steel rail, end (with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. butwithout lamp, HPF suitable for street or outdoor lighting - 2x36/40 watt
OL0026
Supplying of prewired street lighting fluoresent lamp luminiaries housing of CRCA sheet steel rail, end (with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for street or outdoor lighting - 1x18/20 watt
OL0027
Labour and Material Coefficients (Electrical)- 2013 Page 184
Department of Engineering Services, MoWHS
Code Description Quant Units MT6062 Street Lighting - 1x18/20 W, HPF 1 each
Coefficient for per each of OL0040
Code Description Quant Units MT6075 Street Light Luminiareis - 1x80 W, HPL-N(BC) 1 each
Coefficient for per each of OL0041
Code Description Quant Units MT6076 Street Light Luminiareis - 1x125 W, HPL-N(BC) 1 each
Coefficient for per each of OL0042
Code Description Quant Units MT6077 Street Light Luminiareis - 1x250 W, HPL-N(ES) 1 each
Coefficient for per each of OL0055
Code Description Quant Units MT6063 Street Lighting - 1x70 W, (E) SON(BC) 1 each
Coefficient for per each of OL0056
Code Description Quant Units MT6064 Street Lighting - 1x70 W, (I)SON(BC) 1 each
Coefficient for per each of OL0057
Code Description Quant Units MT6065 Street Lighting - 1x100 W, SON(BC) 1 each
Coefficient for per each of OL0058
Code Description Quant Units MT6066 Street Lighting - 1x250 W, SON(ES) 1 each
Supplying of prewired street lighting of high pressure mercury vapour lamp luminiaries housing of CRCA sheet steel comprise of canopy, acrylic cover, control gear housing and 50/60mm outer diameter hole for bracket (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, HPF suitable for street or outdoor lighting mecury vapour lamp - 1x80 watt HPL-N(BC)
OL0040
Supplying of prewired street lighting of high pressure mercury vapour lamp luminiaries housing of CRCA sheet steel comprise of canopy, acrylic cover, control gear housing and 50/60mm outer diameter hole for bracket (with lamp holders, copper wound ballast, condenser, terminal block etc. but without suitable for street or outdoor lighting mecury vapour lamp - 1x125 watt HPL-N(BC)
OL0041
Supplying of prewired street lighting of high pressure mercury vapour lamp luminiaries housing of CRCA sheet steel comprise of canopy, acrylic cover, control gear housing and 50/60mm outer diameter hole for bracket (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, HPF suitable for street or outdoor lighting mecury vapour lamp - 1x250 watt HPL-N(ES)
OL0042
Supplying of prewired street lighting of high pressure sodium vapour lamp luminiaries housing of CRCA sheet steel comprise of canopy, acrylic cover, control gear housing and 50/60mm outer diameter hole for bracket (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, HPF suitable for street or outdoor lighting with sodium lamp - 1x70 watt (E) SON(BC)
OL0055
Supplying of prewired street lighting of high pressure sodium vapour lamp luminiaries housing of CRCA sheet steel comprise of canopy, acrylic cover, control gear housing and 50/60mm outer diameter hole for bracket (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, HPF suitable for street or outdoor lighting with sodium lamp - 1x70 watt(I) SON(BC)
OL0056
Supplying of prewired street lighting of high pressure sodium vapour lamp luminiaries housing of CRCA sheet steel comprise of canopy, acrylic cover, control gear housing and 50/60mm outer diameter hole for bracket (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, HPF suitable for street or outdoor lighting with sodium lamp - 1x100 watt SON(BC)
OL0057
Supplying of prewired street lighting of high pressure sodium vapour lamp luminiaries housing of CRCA sheet steel comprise of canopy, acrylic cover, control gear housing and 50/60mm outer diameter hole for bracket (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, HPF suitable for street or outdoor lighting with sodium lamp - 1x250 watt SON(ES)
OL0058
Labour and Material Coefficients (Electrical)- 2013 Page 185
Department of Engineering Services, MoWHS
Coefficient for per each of OL0070
Code Description Quant Units MT6090 Post Top Lantern - 1x80 W, HPL-N(BC) 1 each
Coefficient for per each of OL0071
Code Description Quant Units MT6091 Post Top Lantern - 1x125 W, HPL-N(ES) 1 each
Coefficient for per each of OL0072
Code Description Quant Units MT6092 Post Top Lantern - 1x160 W, ML(ES) 1 each
Coefficient for per each of OL0085
Code Description Quant Units MT6093 Post Top Lantern - 1x70 (E) W, SON(BC) 1 each
1x70(I) watt SON(BC) Coefficient for per each of OL0086
Code Description Quant Units MT6094 Post Top Lantern - 1x70(I) W, SON(BC) 1 each
Coefficient for per each of OL0087
Code Description Quant Units MT6105 Under water lighting - 60/75/100 W (R), (BC) for depth<0.60m 1 each
Coefficient for per each of OL0100
Code Description Quant Units MT6120 Flood Light Luminiare - 2x250/400 W, HPL-N(ES) 1 each
Underwater luminiare 60/75/100 watt (R)BC upto depth of 0.6m
Supplying of prewired flood lighting fixtures of high pressure mercury/sodium vapour/GLS lamp luminiaries housing of cast/spun aluminium reflector, water protected glass cover, base with lamp holder, capacitor/ignitor, copper wound ballast, terminal block etc. but without lamp, suitable for storeyard / large open area/play ground/monuments, etc - 2x250/400 watt HPL-N(ES)
OL0100
/sperical/similar HDP cover (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, suitable for compound/lawns or outdoor lighting with sodium/reflector lamp -
Supplying of prewired post top lantern/under water lighting of high pressure mercury/sodium vapour self ballasted lamp luminiaries housing of cast aluminium 50/60/80mm OD, double conical / eliptical
/sperical/similar HDP cover (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, suitable for compound/lawns or outdoor lighting with sodium/reflector lamp-
Supplying of prewired post top lantern/under water lighting of high pressure mercury/sodium vapour self ballasted lamp luminiaries housing of cast aluminium 50/60/80mm OD, double conical /eliptical
Supplying of prewired post top lantern lighting of high pressure mercury/sodium vapour self ballasted lamp luminiaries housing of cast aluminium 50/60/80mm OD, double conical / eliptical/sperical/similar HDP cover (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, suitable for compound/lawns or outdoor lighting with mercury lamp - 1x80 watt HPL-N(BC)
OL0070
Supplying of prewired post top lantern lighting of high pressure mercury/sodium vapour self ballasted lamp luminiaries housing of cast aluminium 50/60/80mm OD, double conical / eliptical/sperical/similar HDP cover (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, compound/lawns or outdoor lighting with mercury lamp - 1x125 watt HPL-N(ES)
OL0071
Supplying of prewired post top lantern lighting of high pressure mercury/sodium vapour self ballasted lamp luminiaries housing of cast aluminium 50/60/80mm OD, double conical / eliptical/sperical/similar HDP cover (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, suitable for compound/lawns or outdoor lighting with mercury lamp - 1x60 watt ML(ES)
OL0072
OL0086
OL0087
OL0085/sperical/similar HDP cover (with lamp holders, copper wound ballast, condenser, terminal block etc. with sodium/reflector lamp - 1x70(E) watt SON(BC)
Supplying of prewired post top lantern/under water lighting of high pressure mercury/sodium vapour self ballasted lamp luminiaries housing of cast aluminium 50/60/80mm OD, double conical /eliptical
Labour and Material Coefficients (Electrical)- 2013 Page 186
Department of Engineering Services, MoWHS
Coefficient for per each of OL0101
Code Description Quant Units MT6121 Flood Light Luminiare - 2x250/400 W, SON-T(ES) 1 each
Coefficient for per each of OL0102
Code Description Quant Units MT6122 Flood Light Luminiare - 1x500 W, (ES) 1 each
Coefficient for per each of OL0115
Code Description Quant Units MT6123 Flood Light Luminiare - 1x250/400 W, HPI-T 1 each
Coefficient for per each of OL0116
Code Description Quant Units MT6124 Flood Light Luminiare - Halogen lamp, 1x500 W 1 each
Coefficient for per each of OL0117
Code Description Quant Units MT6125 Flood Light Luminiare - Halogen lamp, 1 or 2x1000 W 1 each
Coefficient for per each of OL0130
Code Description Quant Units MT6140 Industrial well glass - GLS 1x200/300 W (ES) 1 each
Coefficient for per each of OL0131
Code Description Quant Units MT6141 Industrial well glass - 1x80/125 W HPL-N(BC) 1 each
Coefficient for per each of OL0132
Code Description Quant Units MT6142 Industrial well glass - 1x70/100 W (E) SON(BC) 1 each
Supplying of prewired industrial well glass luminiaries housing of die-cast aluminium alloy, porcelain holder, terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium ring,copper ballast, capacitor etc. but without lamp, suitable for GLS/HPL-N/SON lamp - watt HPL-N (BC)
OL0131
Supplying of prewired industrial well glass luminiaries housing of die-cast aluminium alloy, porcelain lamp holder, terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium ring, copper ballast, capacitor etc. but without lamp, suitable for GLS/HPL-N/SON lamp - 1x70/100 watt SON(E/I) (BC)
OL0132
Supplying of prewired flood lighting fixtures of metal halide/halogen lamp luminiaries housing of cast/spun aluminium reflector, water protected glass cover, base with lamp holder, capacitor/ignitor, copper wound ballast, terminal block etc. but without lamp, suitable for storeyard/large open area/ play ground/monuments, etc - 1 or 2x1000 watt halogen lamp
OL0117
Supplying of prewired industrial well glass luminiaries housing of die-cast aluminium alloy, porcelain lamp holder, terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium ringcopper ballast, capacitor etc. but without lamp, suitable for GLS/HPL-N/SON lamp -GLS 1x200/300 watt (ES)
OL0130
Supplying of prewired flood lighting fixtures of metal halide/halogen lamp luminiaries housing of cast/spun aluminium reflector, water protected glass cover, base with lamp holder, capacitor/ignitor,copper wound ballast, terminal block etc. but without lamp, suitable for storeyard/large open area/ play ground/monuments, etc - 2x250/400 watt HPI-T
OL0115
Supplying of prewired flood lighting fixtures of metal halide/halogen lamp luminiaries housing of cast/spun aluminium reflector, water protected glass cover, base with lamp holder, capacitor/ignitor, copper wound ballast, terminal block etc. but without lamp, suitable for storeyard/large open area/ play ground/monuments, etc - 2x500 watt halogen lamp
OL0116
Supplying of prewired flood lighting fixtures of high pressure mercury/sodium vapour/GLS lamp luminiaries housing of cast/spun aluminium reflector, water protected glass cover, base with lamp holder, capacitor/ignitor, copper wound ballast, terminal block etc. but without lamp, suitable for storeyard / large open area/play ground/monuments, etc - 2x250/400 watt SON-T(ES)
OL0101
Supplying of prewired flood lighting fixtures of high pressure mercury/sodium vapour/GLS lamp luminiaries housing of cast/spun aluminium reflector, water protected glass cover, base with lamp holder, capacitor/ignitor, copper wound ballast, terminal block etc. but without lamp, suitable for storeyard / large open area/play ground/monuments, etc - 1x500 watt(ES) GLS lamp
OL0102
Labour and Material Coefficients (Electrical)- 2013 Page 187
Department of Engineering Services, MoWHS
Coefficient for per each of OL0145
Code Description Quant Units MT6155 Flame proof Industrial well glass - 1x60/200 W (BC/ES) 1 each
Coefficient for per each of OL0146
Code Description Quant Units MT6156 Flame proof Industrial well glass - 1x80/125 W HPL-N(BC) 1 each
Coefficient for per each of OL0147
Code Description Quant Units MT6157 Flame proof Industrial well glass - 1x160 W ML-N(ES) 1 each
Coefficient for per each of OL0160
Code Description Quant Units MT6170 Flame proof bulk head - 1x60/200 W GLS(BC/ES) 1 each
Coefficient for per each of OL0161
Code Description Quant Units MT6171 Flame proof bulk head - 1x80/125 W (BC) 1 each
Coefficient for per each of OL0162
Code Description Quant Units MT6172 Flame proof bulk head - 1x160 W ML-N(ES) 1 each
CHAPTER 12: LAMPS & LAMP SHADE
LS0001 Coefficient for per each of LS0001
Code Description Quant Units MT6220 GLS lamp 250 volt A.C - 40 W (BC) 1 each LS0002 Coefficient for per each of LS0002
Code Description Quant Units MT6221 GLS lamp 250 volt A.C - 60 W (BC) 1 each
ring, copper ballast, capacitor etc. but without lamp, suitable for GLS/HPL-N lamp - 1x60 watt ML-N/ES)
Supplying of prewired flame proof industrial well glass luminiaries housing of die-cast aluminium alloy, porcelain lamp holder, terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium
ring, copper ballast, capacitor etc. but without lamp, suitable for GLS/HPL-N lamp - 1x80/125 watt HPL-N (BC)
Supplying of prewired flame proof industrial well glass luminiaries housing of die-cast aluminium alloy, porcelain lamp holder,terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium
Supplying of prewired flame proof bulk head luminiaries housing of die-cast aluminium alloy, porcelain lamp holder, terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium ring, copper ballast, capacitor etc. but without lamp, suitable for HPL-N/ML-N lamp - 1x60/200 watt GLS (BC/ES)
OL0160
Supplying of prewired flame proof bulk head luminiaries housing of die-cast aluminium alloy, porcelain lamp holder, terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium ring, copper ballast, capacitor etc. but without lamp, suitable for HPL-N/ML-N lamp - HPL-N lamp 1x80/125 watt (BC)
copper ballast, capacitor etc. but without lamp, suitable for GLS/HPL-N lamp - GLS 1x60/200 watt (BC/ES)OL0145
Supplying of prewired flame proof bulk head luminiaries housing of die-cast aluminium alloy, porcelain lamp holder, terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium ring, copper ballast, capacitor etc. but without lamp, suitable for HPL-N/ML-N lamp - 1x60 watt ML-N
OL0162
OL0161
OL0146
OL0147
Supplying of prewired flame proof industrial well glass luminiaries housing of die-cast aluminium alloy, porcelain lamp holder, terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium ring,
Supplying of GLS lamps 250 volts A.C - GLS lamp 40 watt (BC)
Supplying of GLS lamps 250 volts A.C - GLS lamp 60 watt (BC)
Labour and Material Coefficients (Electrical)- 2013 Page 188
Department of Engineering Services, MoWHS
LS0003 Coefficient for per each of LS0003
Code Description Quant Units MT6222 GLS lamp 250 volt A.C - 100 W (BC) 1 each LS0004 Coefficient for per each of LS0004
Code Description Quant Units MT6223 GLS lamp 250 volt A.C - 150 W (ES) 1 each LS0005 Coefficient for per each of LS0005
Code Description Quant Units MT6224 GLS lamp 250 volt A.C - 200 W (ES) 1 each LS0006 Coefficient for per each of LS0006
Code Description Quant Units MT6225 GLS lamp 250 volt A.C - 300 W (ES) 1 each LS0020 Coefficient for per each of LS0020
Code Description Quant Units MT6226 GLS lamp 250 volt A.C - 500 W (ES) 1 each LS0021 Coefficient for per each of LS0021
Code Description Quant Units MT6235 Reflector lamp 250 volt A.C - 60 W (R) 63(BC) 1 each LS0022 Coefficient for per each of LS0022
Code Description Quant Units MT6236 Reflector lamp 250 volt A.C - 75 W (R) 95(BC/ES) 1 each
LS0035
Coefficient for per each of LS0035
Code Description Quant Units MT6237 Reflector lamp 250 volt A.C - 100 W (R) 95(BC/ES) 1 each LS0036 Coefficient for per each of LS0036
Code Description Quant Units MT6238 Reflector lamp 250 volt A.C - 150 W (R) 95(BC/ES) 1 each LS0037 Coefficient for per each of LS0037
Code Description Quant Units MT6250 ML blended lamp 250 volt A.C - 60 W (BC/ES) 1 each
Supplying of reflector/ML blended/ self ballasted lamps 250 volts A.C - ML-N lamp 160 watt (BC/ES)
Supplying of GLS lamps 250 volts A.C - GLS lamp 100 watt (BC)
Supplying of reflector/ML blended/ self ballasted lamps 250 volts A.C - Reflector lamp 150 watt 95(BC/ES)
Supplying of GLS/reflector lamps 250 volts A.C - Reflector lamp 60 watt 63(BC)
Supplying of GLS/reflector lamps 250 volts A.C - Reflector lamp 75 watt 95(BC/ES)
Supplying of reflector/ML blended/ self ballasted lamps 250 volts A.C - Reflector lamp 100 watt (R)
Supplying of GLS lamps 250 volts A.C - GLS lamp 150 watt (ES)
Supplying of GLS lamps 250 volts A.C - GLS lamp 200 watt (ES)
Supplying of GLS lamps 250 volts A.C - GLS lamp 100 watt (ES)
Supplying of GLS/reflector lamps 250 volts A.C - GLS lamp 500 watt (ES)
Labour and Material Coefficients (Electrical)- 2013 Page 189
Department of Engineering Services, MoWHS
LS0050 Coefficient for per each of LS0050
Code Description Quant Units MT6265 High pressure mercury vapour lamp 250 volt A.C - HPL-N 80 W (BC/ES) 1 each LS0051 Coefficient for per each of LS0051
Code Description Quant Units MT6266 High pressure mercury vapour lamp 250 volt A.C - HPL-N 125 W (BC/ES) 1 each LS0052 Coefficient for per each of LS0052
Code Description Quant Units MT6267 High pressure mercury vapour lamp 250 volt A.C - HPL-N 250 W (ES) 1 each LS0065 Coefficient for per each of LS0065
Code Description Quant Units MT6268 High pressure mercury vapour lamp 250 volt A.C - HPL-N 400 W (ES) 1 each LS0066 Coefficient for per each of LS0066
Code Description Quant Units MT6285 High pressure sodium vapour lamp 250 volt A.C - SON-T 70 W (E)(BC) 1 each LS0067 Coefficient for per each of LS0067
Code Description Quant Units MT6286 High pressure sodium vapour lamp 250 volt A.C - SON-T 70 W (I) (BC) 1 each LS0080 Coefficient for per each of LS0080
Code Description Quant Units MT6287 High pressure sodium vapour lamp 250 volt A.C - SON-T 150 W (ES) 1 each LS0081 Coefficient for per each of LS0081
Code Description Quant Units MT6288 High pressure sodium vapour lamp 250 volt A.C - SON-T 250 W (ES) 1 each LS0082 Coefficient for per each of LS0082
Code Description Quant Units MT6289 High pressure sodium vapour lamp 250 volt A.C - SON-T 400 W (ES) 1 each LS0095 Coefficient for per each of LS0095
Code Description Quant Units MT6300 Metal halide lamp 250 volt A.C - HPI-T 250 W (ES) 1 each
Supplying of high pressure mercury/sodium vapour lamps 250 volts A.C - SON-T lamp 70 watt (I) (BC)
Supplying of high pressure sodium vapour lamps 250 volts A.C - SON-T lamp 150 watt (ES)
Supplying of high pressure mercury vapour lamps 250 volts A.C - HPL-N lamp 80 watt (BC/ES)
Supplying of high pressure mercury/sodium vapour lamps 250 volts A.C - HPL-N lamp 400 watt (ES)
Supplying of high pressure mercury/sodium vapour lamps 250 volts A.C - SON-T lamp 70 watt (E) (BC)
Supplying of high pressure mercury vapour lamps 250 volts A.C - HPL-N lamp 125 watt (BC/ES)
Supplying of high pressure mercury vapour lamps 250 volts A.C - HPL-N lamp 250 watt (ES)
Supplying of high pressure sodium vapour lamps 250 volts A.C - SON-T lamp 250 watt (ES)
Supplying of high pressure sodium vapour lamps 250 volts A.C - SON-T lamp 400 watt (ES)
Supplying of high pressure metal halide/halogen lamps 250 volts A.C - HPI-T lamp 250 watt (ES)
Labour and Material Coefficients (Electrical)- 2013 Page 190
Department of Engineering Services, MoWHS
LS0096 Coefficient for per each of LS0096
Code Description Quant Units MT6301 Metal halide lamp 250 volt A.C - HPI-T 400 W (ES) 1 each LS0097 Coefficient for per each of LS0097
Code Description Quant Units MT6315 Halogen lamp 250 volt A.C - 7785 R 500 W 1 each LS0110 Coefficient for per each of LS0110
Code Description Quant Units MT6316 Halogen lamp 250 volt A.C - 12013 R 1000 W 1 each
LS0111
Coefficient for per each of LS0111
Code Description Quant Units MT6325 Argenta superlux lamp 250 volt A.C - 60 W (BC) 1 each
LS0112
Coefficient for per each of LS0112
Code Description Quant Units MT6335 Special incandescent lamp 250 volt A.C - 15 W (BC) pigmy 1 each LS0125 Coefficient for per each of LS0125
Code Description Quant Units MT6345 Fluorescent lamp 250 volt A.C - TL 18/20 W 1 each LS0126 Coefficient for per each of LS0126
Code Description Quant Units MT6346 Fluorescent lamp 250 volt A.C - TL 36/40 W 1 each LS0127 Coefficient for per each of LS0127
Code Description Quant Units MT6347 Fluorescent lamp 250 volt A.C - TLF 36/40 W 1 each
LS0140
Coefficient for per each of LS0140
Code Description Quant Units MT6355 Glass globe - 150mm dia 1 each
LS0141
Coefficient for per each of LS0141
Code Description Quant Units MT6356 Glass globe - 180mm dia 1 each
Supplying of high pressure metal halide/halogen lamps 250 volts A.C - Halogen lamp 7785 R 500 watt
Supplying of halogen/argenta superlux/special incandescent lamps 250 volts A.C - Halogen 12013 R 1000 watt
Supplying of halogen/argenta superlux/special incandescent lamps 250 volts A.C - Argenta superlux 60 watt (BC)
Supplying of halogen/argenta superlux/special incandescent lamps 250 volts A.C - 15 watt (BC) pigmy lamp
Supplying of high pressure metal halide/halogen lamps 250 volts A.C - HPI-T lamp 400 watt (ES)
Supplying of glass globe/glass lengum shade as required to make the existing fitting good - Glass globe 180mm dia
Supplying of fluorescent lamps 250 volts A.C - TL lamp 18/20 watt
Supplying of fluorescent lamps 250 volts A.C - TL lamp 36/40 watt
Supplying of fluorescent lamps 250 volts A.C - TLF lamp 36/40 watt
Supplying of glass globe/glass lengum shade as required to make the existing fitting good - Glass globe 150mm dia
Labour and Material Coefficients (Electrical)- 2013 Page 191
Department of Engineering Services, MoWHS
LS0142
Coefficient for per each of LS0142
Code Description Quant Units MT6365 Glass lengum shade - 150mm dia 1 each
LS0155
Coefficient for per each of LS0155
Code Description Quant Units MT6366 Glass lengum shade - 180mm dia 1 each
LS0156
Coefficient for per each of LS0156
Code Description Quant Units MT6375 Heat resistant proof plastic conical shade - 150mm dia 1 each
LS0157
Coefficient for per each of LS0157
Code Description Quant Units MT6385 Heat resistant proof plastic coolican shade - 150mm dia 1 each
CHAPTER 13: FANS (Supply)
FN0001
Coefficient for per each of FN0001
Code Description Quant Units MT6395 Ceiling fan 240 volt A.C - 1400 rpm, 900mm sweep 1 each
FN0002
Coefficient for per each of FN0002
Code Description Quant Units MT6396 Ceiling fan 240 volt A.C - 1400 rpm, 1200mm sweep 1 each
FN0003
Coefficient for per each of FN0003
Code Description Quant Units MT6397 Ceiling fan 240 volt A.C - 1400 rpm, 1400mm sweep 1 each
FN0015
Coefficient for per each of FN0015
Code Description Quant Units MT6415 Exhaust fan 240 volt A.C - 900 rpm, 300mm sweep 1 each
FN0016
Coefficient for per each of FN0016
Code Description Quant Units MT6416 Exhaust fan 240 volt A.C - 900 rpm, 380mm sweep 1 each
Supplying of ceiling fan 240 volt A.C 1400 rpm with all accessories such as down rod, sweep 3 Nos., canopy 2 Nos., condenser and fan body etc. complete as required - 1200mm sweep
Supplying of ceiling fan 240 volt A.C 1400 rpm with all accessories such as down rod, sweep 3 Nos., canopy 2 Nos., condenser and fan body etc. complete as required - 1400mm sweep
Supplying of exhaust fan 240 volt A.C 900 rpm with all accessories such as frame with arm 3 Nos., sweep 3 Nos., condenser and fan body etc. complete as required - 300mm sweep
Supplying of exhaust fan 240 volt A.C 900 rpm with all accessories such as frame with arm 3 Nos., sweep 3 Nos., condenser and fan body etc. complete as required - 380mm sweep
Supplying of glass lengum shade/heat resistant proof plastic conical/coonican shade as required to make the existing fitting good - PLastic heat resistant shade 150mm dia
Supplying of glass lengum shade/heat resistant proof plastic conical/coonican shade as required to make the existing fitting good - Glass lengum shade 180mm dia
Supplying of glass globe/glass lengum shade as required to make the existing fitting good - Glass lengum shade 150mm dia
Supplying of glass lengum shade/heat resistant proof plastic conical/coonican shade as required to make the existing fitting good - Plastic heat resistant coonican shade 150mm dia
Supplying of ceiling fan 240 volt A.C 1400 rpm with all accessories such as down rod, sweep 3 Nos., canopy 2 Nos., condenser and fan body etc. complete as required - 900mm sweep
Labour and Material Coefficients (Electrical)- 2013 Page 192
Department of Engineering Services, MoWHS
FN0017
Coefficient for per each of FN0017
Code Description Quant Units MT6417 Exhaust fan 240 volt A.C - 900 rpm, 450mm sweep 1 each
FN0030
Coefficient for per each of FN0030
Code Description Quant Units MT6418 Exhaust fan 240 volt A.C - 1400 rpm, 300mm sweep 1 each
FN0031
Coefficient for per each of FN0031
Code Description Quant Units MT6419 Exhaust fan 240 volt A.C - 1400 rpm, 380mm sweep 1 each
FN0032
Coefficient for per each of FN0032
Code Description Quant Units MT6420 Exhaust fan 240 volt A.C - 1400 rpm, 450mm sweep 1 each FN0045 Coefficient for per each of FN0045
Code Description Quant Units MT6435 Aluminium louvere with frame - 300mm sweep 1 each FN0046 Coefficient for per each of FN0046
Code Description Quant Units MT6436 Aluminium louvere with frame - 380mm sweep 1 each FN0047 Coefficient for per each of FN0047
Code Description Quant Units MT6437 Aluminium louvere with frame - 450mm sweep 1 each
CHAPTER 14: CONTROL GEAR & BUSBAR (Supply)
GB0001
Coefficient for per each of GB0001
Code Description Quant Units MT4960 Copper Busbars & MS Busbar Chamber - 2 strips, 300mm bar, 100A 1 each
GB0002
Coefficient for per each of GB0002
Code Description Quant Units MT4961 Copper Busbars & MS Busbar Chamber - 4 strips, 300mm bar, 100A 1 each
Supplying of exhaust fan 240 volt A.C 1400 rpm with all accessories such as frame with arm 3 Nos., sweep 3 Nos., condenser and fan body etc. complete as required - 380mm sweep
Supplying of exhaust fan 240 volt A.C 1400 rpm with all accessories such as frame with arm 3 Nos., sweep 3 Nos., condenser and fan body etc. complete as required - 450mm sweep
Supplying of exhaust fan 240 volt A.C 900 rpm with all accessories such as frame with arm 3 Nos., sweep 3 Nos., condenser and fan body etc. complete as required - 450mm sweep
Supplying of exhaust fan 240 volt A.C 1400 rpm with all accessories such as frame with arm 3 Nos., sweep 3 Nos., condenser and fan body etc. complete as required - 300mm sweep
Supplying of Aluminium louveres for exhaust fan complete all accessories as required - 300mm sweep
Supplying of Aluminium louveres for exhaust fan complete all accessories as required - 380mm sweep
Supplying of Aluminium louveres for exhaust fan complete all accessories as required - 450mm sweep
Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 2 strips, 300mm bar, 100A
Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 4 strips, 300mm bar, 100A
Labour and Material Coefficients (Electrical)- 2013 Page 193
Department of Engineering Services, MoWHS
GB0003
Coefficient for per each of GB0003
Code Description Quant Units MT4962 Copper Busbars & MS Busbar Chamber - 4 strips, 300mm bar, 200A 1 each
GB0004
Coefficient for per each of GB0004
Code Description Quant Units MT4963 Copper Busbars & MS Busbar Chamber - 2 strips, 450mm bar, 100A 1 each
GB0005
Coefficient for per each of GB0005
Code Description Quant Units MT4964 Copper Busbars & MS Busbar Chamber - 4 strips, 450mm bar, 100A 1 each
GB0006
Coefficient for per each of GB0006
Code Description Quant Units MT4965 Copper Busbars & MS Busbar Chamber - 4 strips, 450mm bar, 200A 1 each
GB0007
Coefficient for per each of GB0007
Code Description Quant Units MT4966 Copper Busbars & MS Busbar Chamber - 4 strips, 600mm bar, 100A 1 each
GB0008
Coefficient for per each of GB0008
Code Description Quant Units MT4967 Copper Busbars & MS Busbar Chamber - 4 strips, 600mm bar, 200A 1 each
GB0009
Coefficient for per each of GB0009
Code Description Quant Units MT4968 Copper Busbars & MS Busbar Chamber - 4 strips, 600mm bar, 300A 1 each
GB0025
Coefficient for per each of GB0025
Code Description Quant Units
MT4980Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 600mm bar, 300A 1 each
GB0026
Coefficient for per each of GB0026
Code Description Quant Units
MT4981Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 600mm bar, 400A 1 each
Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 4 strips, 300mm bar, 200A
Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 2 strips, 450mm bar, 100A
Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 4 strips, 450mm bar, 100A
Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 4 strips, 450mm bar, 200A
Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 4 strips, 600mm bar,100A
Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 4 strips, 600mm bar, 200A
Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 4 strips, 600mm bar, 300A
Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 600mm bar, 300A
Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 600mm bar, 400A
Labour and Material Coefficients (Electrical)- 2013 Page 194
Department of Engineering Services, MoWHS
GB0027
Coefficient for per each of GB0027
Code Description Quant Units
MT4982Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 600mm bar, 600A 1 each
GB0028
Coefficient for per each of GB0028
Code Description Quant Units
MT4983Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 900mm bar, 400A 1 each
GB0029
Coefficient for per each of GB0029
Code Description Quant Units
MT4984Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 900mm bar, 600A 1 each
GB0030
Coefficient for per each of GB0030
Code Description Quant Units
MT4985Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 900mm bar, 800A 1 each
GB0031
Coefficient for per each of GB0031
Code Description Quant Units
MT4986Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 1350mm bar, 400A 1 each
GB0032
Coefficient for per each of GB0032
Code Description Quant Units
MT4987Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 1350mm bar, 600A 1 each
GB0033
Coefficient for per each of GB0033
Code Description Quant Units
MT4988Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 1350mm bar, 800A 1 each
GB0050
Coefficient for per each of GB0050
Code Description Quant Units
MT5000 Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 20A, 415V 1 each MT5045 HRC Fuses - 20A, 415V size 0 3 each
Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 600mm bar, 600A
Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 900mm bar, 400A
Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 900mm bar, 600A
Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 900mm bar, 800A
Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 1350mm bar, 400A
Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 1350mm bar, 600A
Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 1350mm bar, 800A
Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN switch fuse unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 20A
Labour and Material Coefficients (Electrical)- 2013 Page 195
Department of Engineering Services, MoWHS
GB0051
Coefficient for per each of GB0051
Code Description Quant Units
MT5001 Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 32A,415V, SFU 1 each MT5046 HRC Fuses - 32A, 415V size 0 3 each
GB0052
Coefficient for per each of GB0052
Code Description Quant Units
MT5002 Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 63A,415V, SFU 1 each MT5047 HRC Fuses - 63A, 415V size 0 3 each
GB0053
Coefficient for per each of GB0053
Code Description Quant Units
MT5006Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 125A, 415V, SFU 1 each
MT5048 HRC Fuses - 125A, 415V size 1 3 each
GB0065
Coefficient for per each of GB0065
Code Description Quant Units
MT5003Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 200A,415V, FSU 1 each
MT5049 HRC Fuses - 200A, 415V size 1 3 each
GB0066
Coefficient for per each of GB0066
Code Description Quant Units
MT5004Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 250A, 415V, FSU 1 each
MT5050 HRC Fuses - 250A, 415V size 1 3 each
GB0067
Coefficient for per each of GB0067
Code Description Quant Units
MT5005Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 315A, 415V, FSU 1 each
MT5051 HRC Fuses - 315A, 415V size 2 3 each
GB0068
Coefficient for per each of GB0068
Code Description Quant Units
MT5007Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 400A,415V, FSU 1 each
MT5052 HRC Fuses - 400A, 415V size 2 3 each
Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN switch fuse unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 32A
Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN switch fuse unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 63A
Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN switch fuse unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 125A
Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN fuse switch unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 200A
Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN fuse switch unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 250A
Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN fuse switch unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 315A
Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN fuse switch unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 400A
Labour and Material Coefficients (Electrical)- 2013 Page 196
Department of Engineering Services, MoWHS
GB0069
Coefficient for per each of GB0069
Code Description Quant Units
MT5008Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 500A,415V, FSU 1 each
MT5053 HRC Fuses - 500A, 415V size 3 3 each
GB0070
Coefficient for per each of GB0070
Code Description Quant Units
MT5009Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 630A,415V, FSU 1 each
MT5054 HRC Fuses - 630A, 415V size 3 3 each
GB0071
Coefficient for per each of GB0071
Code Description Quant Units
MT5011Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 800A,415V, FSU 1 each
MT5056 HRC Fuses - 800A, 415V size 3 3 each
GB0085
Coefficient for per each of GB0085
Code Description Quant Units
MT5012Wall mounting Fuse Switch Units sheet steel enclosure - 4 pole, 500A, 415V, FSU 1 each
MT5053 HRC Fuses - 500A, 415V size 3 4 each
Coefficient for per each of GB0095
Code Description Quant Units
MT5004Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 250A, 415V, FSU 1 each
MT5050 HRC Fuses - 250A, 415V size 1 4 each
Coefficient for per each of GB0096
Code Description Quant Units
MT5007Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 400A, 415V, FSU 1 each
MT5052 HRC Fuses - 400A, 415V size 2 4 each
Coefficient for per each of GB0097
Code Description Quant Units
MT5010 Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 750A,415V FSU 1 each MT5055 HRC Fuses-750A, 415V Size 3 4 each
Supplying of wall mounting combination fuse switch unit with sheet steel enclosure /panel mounting disconnector fuse switch unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 4 pole with HRC fuses and all accessories etc. as required - 400A
GB0096
Supplying of wall mounting combination fuse switch unit with sheet steel enclosure /panel mounting disconnector fuse switch unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 4 pole with HRC fuses and all accessories etc. as required - 750A
GB0097
Supplying of wall mounting combination fuse switch unit with sheet steel enclosure /panel mounting disconnector fuse switch unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 4 pole with HRC fuses and all accessories etc. as required - 250A
GB0095
Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN fuse switch unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 500A
Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN fuse switch unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 630A
Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN fuse switch unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 800A
Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure 4 pole fuse switch unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 500A
Labour and Material Coefficients (Electrical)- 2013 Page 197
Department of Engineering Services, MoWHS
Coefficient for per each of GB0110
Code Description Quant Units
MT5028Panel mounting disconnector FSU complete with front drive mechanism with door interlock (HRC fuse)-3 pole, 32A, 415V, SFU 1 each
MT5046 HRC Fuses - 32A, 415V size 0 3 each
Coefficient for per each of GB0111
Code Description Quant Units
MT5029Panel mounting disconnector FSU complete with front drive mechanism with door interlock (HRC fuse)-3 pole, 63A, 415V, SFU 1 each
MT5047 HRC Fuses - 63A, 415V size 0 3 each
Coefficient for per each of GB0112
Code Description Quant Units
MT5030Panel mounting disconnector FSU complete with front drive mechanism with door interlock (HRC fuse)-3 pole, 125A, 415V, SFU 1 each
MT5048 HRC Fuses - 125A, 415V size 1 3 each
Coefficient for per each of GB0125
Code Description Quant Units
MT5031Panel mounting disconnector FSU complete with front drive mechanism with door interlock (HRC fuse)-3 pole, 250A, 415V, FSU 1 each
MT5050 HRC Fuses - 250A, 415V size 1 3 each
Coefficient for per each of GB0126
Code Description Quant Units
MT5032Panel mounting disconnector FSU complete with front drive mechanism with door interlock (HRC fuse)-3 pole, 400A, 415V, FSU 1 each
MT5052 HRC Fuses - 400A, 415V size 2 3 each
Coefficient for per each of GB0140
Code Description Quant Units
MT5027Panel mounting disconnector FSU complete with front drive mechanism with door interlock (HRC fuse)-4 pole, 125A, 415V, SFU 1 each
MT5048 HRC Fuses - 125A, 415V size 1 4 each
GB0150
Coefficient for per each of GB0150
Code Description Quant Units MT5640 3 pole, 16KA, MCCB 63A, 415V 1 each
GB0151
Coefficient for per each of GB0151
Code Description Quant Units MT5641 3 pole, 16KA, MCCB 100A, 415V 1 each
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 16KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 63A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 16KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 100A
Supplying of panel mounting switch disconnector fuse switch unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 3 pole fuse switch unit with HRC fuses and all accessories etc. as required - 400A
GB0126
Supplying of panel mounting switch disconnector switch fuse unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 4 pole switch fuse unit with HRC fuses and all accessories etc. as required - 125A
GB0140
Supplying of panel mounting switch disconnector switch fuse unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 3 pole switch fuse unit with HRC fuses and all accessories etc. as required - 125A
GB0112
Supplying of panel mounting switch disconnector fuse switch unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 3 pole fuse switch unit with HRC fuses and all accessories etc. as required - 250A
GB0125
Supplying of panel mounting switch disconnector switch fuse unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 3 pole switch fuse unit with HRC fuses and all accessories etc. as required - 32A
GB0110
Supplying of panel mounting switch disconnector switch fuse unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 3 pole switch fuse unit with HRC fuses and all accessories etc. as required - 63A
GB0111
Labour and Material Coefficients (Electrical)- 2013 Page 198
Department of Engineering Services, MoWHS
GB0152
Coefficient for per each of GB0152
Code Description Quant Units MT5642 3 pole, 16KA, MCCB 125A, 415V 1 each
GB0165
Coefficient for per each of GB0165
Code Description Quant Units MT5643 4 pole, 16KA, MCCB 63A, 415V 1 each
GB0166
Coefficient for per each of GB0166
Code Description Quant Units MT5644 4 pole, 16KA, MCCB 100A, 415V 1 each
GB0167
Coefficient for per each of GB0167
Code Description Quant Units MT5645 4 pole, 16KA, MCCB 125A, 415V 1 each
GB0180
Coefficient for per each of GB0180
Code Description Quant Units MT5646 3 pole, 25KA, MCCB 63A, 415V 1 each
GB0181
Coefficient for per each of GB0181
Code Description Quant Units MT5647 3 pole, 25KA, MCCB 100A, 415V 1 each
GB0182
Coefficient for per each of GB0182
Code Description Quant Units MT5648 3 pole, 25KA, MCCB 125A, 415V 1 each
GB0195
Coefficient for per each of GB0195
Code Description Quant Units MT5649 4 pole, 25KA, MCCB 63A, 415V 1 each
GB0196
Coefficient for per each of GB0196
Code Description Quant Units MT5650 4 pole, 25KA, MCCB 100A, 415V 1 each
GB0197
Coefficient for per each of GB0197
Code Description Quant Units MT5651 4 pole, 25KA, MCCB 125A, 415V 1 each
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 25KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 63A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 25KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 100A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 25KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 125A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 16KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 125A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 16KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 63A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 16KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 100A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 16KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 125A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 25KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 63A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 25KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 100A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 25KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 125A
Labour and Material Coefficients (Electrical)- 2013 Page 199
Department of Engineering Services, MoWHS
GB0210
Coefficient for per each of GB0210
Code Description Quant Units MT5652 3 pole, 36KA, MCCB 125A, 415V 1 each
GB0211
Coefficient for per each of GB0211
Code Description Quant Units MT5653 3 pole, 36KA, MCCB 160A, 415V 1 each
GB0212
Coefficient for per each of GB0212
Code Description Quant Units MT5654 3 pole, 36KA, MCCB 250A, 415V 1 each
GB0225
Coefficient for per each of GB0225
Code Description Quant Units MT5655 4 pole, 36KA, MCCB 125A, 415V 1 each
GB0226
Coefficient for per each of GB0226
Code Description Quant Units MT5656 4 pole, 36KA, MCCB 160A, 415V 1 each
GB0227
Coefficient for per each of GB0227
Code Description Quant Units MT5657 4 pole, 36KA, MCCB 250A, 415V 1 each
GB0240
Coefficient for per each of GB0240
Code Description Quant Units MT5658 4 pole, 70KA, MCCB 250A, 415V 1 each
GB0241
Coefficient for per each of GB0241
Code Description Quant Units MT5659 4 pole, 70KA, MCCB 400A, 415V 1 each
GB0242
Coefficient for per each of GB0242
Code Description Quant Units MT5660 4 pole, 70KA, MCCB 630A, 415V 1 each
GB0243
Coefficient for per each of GB0243
Code Description Quant Units MT5661 4 pole, 70KA, MCCB 800A, 415V 1 each
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 70KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 800A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 36KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 125A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 36KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 160A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 36KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 250A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 70KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 250A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 70KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 400A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 70KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 630A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 36KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 125A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 36KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 160A
Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 36KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 250A
Labour and Material Coefficients (Electrical)- 2013 Page 200
Department of Engineering Services, MoWHS
GB255
Coefficient for per each of GB0255
Code Description Quant Units MT5070 Earth leakage module, 4 pole, 415 volt A.C - 125A 1 each
GB0256
Coefficient for per each of GB0256
Code Description Quant Units MT5071 Earth leakage module, 4 pole, 415 volt A.C - 160A 1 each
GB0257
Coefficient for per each of GB0257
Code Description Quant Units MT5072 Earth leakage module, 4 pole, 415 volt A.C - 250A 1 each
GB0258
Coefficient for per each of GB0258
Code Description Quant Units MT5073 Earth leakage module, 4 pole, 415 volt A.C - 400A 1 each
GB0259
Coefficient for per each of GB0259
Code Description Quant Units MT5074 Earth leakage module, 4 pole, 415 volt A.C - 630A 1 each
GB0270
Coefficient for per each of GB0270
Code Description Quant Units MT5085 Single pole MCB 230 volt A.C - 6A 1 each
GB0271
Coefficient for per each of GB0271
Code Description Quant Units MT5086 Single pole MCB 230 volt A.C - 10A 1 each
GB0272
Coefficient for per each of GB0272
Code Description Quant Units MT5087 Single pole MCB 230 volt A.C - 16A 1 each
GB0273
Coefficient for per each of GB0273
Code Description Quant Units MT5088 Single pole MCB 230 volt A.C - 20A 1 each
GB0274
Coefficient for per each of GB0274
Code Description Quant Units MT5089 Single pole MCB 230 volt A.C - 25A 1 each
GB0275
Coefficient for per each of GB0275
Code Description Quant Units MT5090 Single pole MCB 230 volt A.C - 32A 1 each
Supply of miniature circuit breaker (MCB) single pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 6A
Supply of miniature circuit breaker (MCB) single pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A
Supply of miniature circuit breaker (MCB) single pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 20A
Supply of miniature circuit breaker (MCB) single pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A
Supply of miniature circuit breaker (MCB) single pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A
Supply of miniature circuit breaker (MCB) single pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 10A
Supply of panel mounting earth leakage module 4 pole, 415 volt A.C complete with all accessories as required - 125A
Supply of panel mounting earth leakage module 4 pole, 415 volt A.C complete with all accessories as required - 160A
Supply of panel mounting earth leakage module 4 pole, 415 volt A.C complete with all accessories as required - 250A
Supply of panel mounting earth leakage module 4 pole, 415 volt A.C complete with all accessories as required - 400A
Supply of panel mounting earth leakage module 4 pole, 415 volt A.C complete with all accessories as required - 630A
Labour and Material Coefficients (Electrical)- 2013 Page 201
Department of Engineering Services, MoWHS
GB0276
Coefficient for per each of GB0276
Code Description Quant Units MT5091 Single pole MCB 230 volt A.C - 40A 1 each
GB0277
Coefficient for per each of GB0277
Code Description Quant Units MT5092 Single pole MCB 230 volt A.C - 63A 1 each
GB0290
Coefficient for per each of GB0290
Code Description Quant Units MT5115 SPN MCB, 230 volt A.C - 6A 1 each
GB0291
Coefficient for per each of GB0291
Code Description Quant Units MT5116 SPN MCB, 230 volt A.C - 10A 1 each
GB0292
Coefficient for per each of GB0292
Code Description Quant Units MT5117 SPN MCB, 230 volt A.C - 16A 1 each
GB0293
Coefficient for per each of GB0293
Code Description Quant Units MT5118 SPN MCB, 230 volt A.C - 20A 1 each
GB0294
Coefficient for per each of GB0294
Code Description Quant Units MT5119 SPN MCB, 230 volt A.C - 25A 1 each
GB0295
Coefficient for per each of GB0295
Code Description Quant Units MT5120 SPN MCB, 230 volt A.C - 32A 1 each
GB0296
Coefficient for per each of GB0296
Code Description Quant Units MT5121 SPN MCB, 230 volt A.C - 40A 1 each
GB0297
Coefficient for per each of GB0297
Code Description Quant Units MT5122 SPN MCB, 230 volt A.C - 63A 1 each
GB0310
Coefficient for per each of GB0310
Code Description Quant Units MT5145 2 pole MCB, 230 volt A.C - 6A 1 each
Supply of miniature circuit breaker (MCB) SPN, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A
Supply of miniature circuit breaker (MCB) SPN, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A
Supply of miniature circuit breaker (MCB) SPN, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A
Supply of miniature circuit breaker (MCB) SPN, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A
Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 6A
Supply of miniature circuit breaker (MCB) single pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A
Supply of miniature circuit breaker (MCB) single pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A
Supply of miniature circuit breaker (MCB) SPN, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 6A
Supply of miniature circuit breaker (MCB) SPN, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 10A
Supply of miniature circuit breaker (MCB) SPN, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A
Supply of miniature circuit breaker (MCB) SPN, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 20A
Labour and Material Coefficients (Electrical)- 2013 Page 202
Department of Engineering Services, MoWHS
GB0311
Coefficient for per each of GB0311
Code Description Quant Units MT5146 2 pole MCB, 230 volt A.C - 10A 1 each
GB0312
Coefficient for per each of GB0312
Code Description Quant Units MT5147 2 pole MCB, 230 volt A.C - 16A 1 each
GB0313
Coefficient for per each of GB0313
Code Description Quant Units MT5148 2 pole MCB, 230 volt A.C - 20A 1 each
GB0314
Coefficient for per each of GB0314
Code Description Quant Units MT5149 2 pole MCB, 230 volt A.C - 25A 1 each
GB0315
Coefficient for per each of GB0315
Code Description Quant Units MT5150 2 pole MCB, 230 volt A.C - 32A 1 each
GB0316
Coefficient for per each of GB0316
Code Description Quant Units MT5151 2 pole MCB, 230 volt A.C - 40A 1 each
GB0317
Coefficient for per each of GB0317
Code Description Quant Units MT5152 2 pole MCB, 230 volt A.C - 50A 1 each
GB0318
Coefficient for per each of GB0318
Code Description Quant Units MT5153 2 pole MCB, 230 volt A.C - 63A 1 each
GB0330
Coefficient for per each of GB0330
Code Description Quant Units MT5180 TP MCB, 415 volt A.C - 6A 1 each
GB0331
Coefficient for per each of GB0331
Code Description Quant Units MT5181 TP MCB, 415 volt A.C - 10A 1 each
GB0332
Coefficient for per each of GB0332
Code Description Quant Units MT5182 TP MCB, 415 volt A.C - 16A 1 each
Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A
Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 6A
Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 10A
Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A
Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A
Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 20A
Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A
Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A
Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A
Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 50A
Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 10A
Labour and Material Coefficients (Electrical)- 2013 Page 203
Department of Engineering Services, MoWHS
GB0333
Coefficient for per each of GB0333
Code Description Quant Units MT5183 TP MCB, 415 volt A.C - 20A 1 each
GB0334
Coefficient for per each of GB03432
Code Description Quant Units MT5184 TP MCB, 415 volt A.C - 25A 1 each
GB0335
Coefficient for per each of GB0335
Code Description Quant Units MT5185 TP MCB, 415 volt A.C - 32A 1 each
GB0336
Coefficient for per each of GB0336
Code Description Quant Units MT5186 TP MCB, 415 volt A.C - 40A 1 each
GB0337
Coefficient for per each of GB0337
Code Description Quant Units MT5187 TP MCB, 415 volt A.C - 50A 1 each
GB0338
Coefficient for per each of GB0338
Code Description Quant Units MT5188 TP MCB, 415 volt A.C - 63A 1 each
GB0350
Coefficient for per each of GB0350
Code Description Quant Units MT5223 TPN MCB, 415 volt A.C - 20A 1 each
GB0351
Coefficient for per each of GB0351
Code Description Quant Units MT5224 TPN MCB, 415 volt A.C - 25A 1 each
GB0352
Coefficient for per each of GB0352
Code Description Quant Units MT5225 TPN MCB, 415 volt A.C - 32A 1 each
GB0353
Coefficient for per each of GB0353
Code Description Quant Units MT5226 TPN MCB, 415 volt A.C - 40A 1 each
GB0354
Coefficient for per each of GB0354
Code Description Quant Units MT5227 TPN MCB, 415 volt A.C - 50A 1 each
Supply of miniature circuit breaker (MCB) triple pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 32A
Supply of miniature circuit breaker (MCB) triple pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 40A
Supply of miniature circuit breaker (MCB) triple pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 50A
Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A
Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A
Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 50A
Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A
Supply of miniature circuit breaker (MCB) triple pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 20A
Supply of miniature circuit breaker (MCB) triple pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 25A
Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 20A
Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A
Labour and Material Coefficients (Electrical)- 2013 Page 204
Department of Engineering Services, MoWHS
GB0355
Coefficient for per each of GB0355
Code Description Quant Units MT5228 TPN MCB, 415 volt A.C - 63A 1 each
GB0365
Coefficient for per each of GB0365
Code Description Quant Units MT5263 4 pole MCB, 415 volt A.C - 20A 1 each
GB0366
Coefficient for per each of GB0366
Code Description Quant Units MT5264 4 pole MCB, 415 volt A.C - 25A 1 each
GB0367
Coefficient for per each of GB0367
Code Description Quant Units MT5265 4 pole MCB, 415 volt A.C - 32A 1 each
GB0368
Coefficient for per each of GB0368
Code Description Quant Units MT5266 4 pole MCB, 415 volt A.C - 40A 1 each
GB0369
Coefficient for per each of GB0369
Code Description Quant Units MT5267 4 pole MCB, 415 volt A.C - 50A 1 each
GB0370
Coefficient for per each of GB0370
Code Description Quant Units MT5268 4 pole MCB, 415 volt A.C - 63A 1 each
GB0380
Coefficient for per each of GB0380
Code Description Quant Units MT5301 DP Isolators, 230 volt A.C - 40A 1 each
GB0381
Coefficient for per each of GB0381
Code Description Quant Units MT5302 DP Isolators, 230 volt A.C - 63A 1 each
GB0395
Coefficient for per each of GB0395
Code Description Quant Units MT5321 TP Isolators, 415 volt A.C - 40A 1 each
GB0396
Coefficient for per each of GB0396
Code Description Quant Units MT5322 TP Isolators, 415 volt A.C - 63A 1 each
Supply of loadkontak isolator triple pole, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 40A
Supply of loadkontak isolator triple pole, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 63A
Supply of miniature circuit breaker (MCB) 4 pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 32A
Supply of miniature circuit breaker (MCB) 4 pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 40A
Supply of miniature circuit breaker (MCB) 4 pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 50A
Supply of miniature circuit breaker (MCB) 4 pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 63A
Supply of loadkontak isolator double pole, 230 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 40A
Supply of loadkontak isolator double pole, 230 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 63A
Supply of miniature circuit breaker (MCB) triple pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 63A
Supply of miniature circuit breaker (MCB) 4 pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 20A
Supply of miniature circuit breaker (MCB) 4 pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 25A
Labour and Material Coefficients (Electrical)- 2013 Page 205
Department of Engineering Services, MoWHS
GB0410
Coefficient for per each of GB0410
Code Description Quant Units MT5340 DP Timer switch , 230 volt A.C - 24hrs/24hrs 1 each
GB0411
Coefficient for per each of GB0411
Code Description Quant Units MT5341 DP Timer switch , 230 volt A.C - 7days/24hrs 1 each
GB0425
Coefficient for per each of GB0425
Code Description Quant Units MT5350 2 pole RCCB, 230 volt A.C, 30mA - 16A 1 each
GB0426
Coefficient for per each of GB0426
Code Description Quant Units MT5351 2 pole RCCB, 230 volt A.C, 30mA - 25A 1 each
GB0427
Coefficient for per each of GB0427
Code Description Quant Units MT5352 2 pole RCCB, 230 volt A.C, 30mA - 32A 1 each
GB0428
Coefficient for per each of GB0428
Code Description Quant Units MT5353 2 pole RCCB, 230 volt A.C, 30mA - 40A 1 each
GB0429
Coefficient for per each of GB0429
Code Description Quant Units MT5354 2 pole RCCB, 230 volt A.C, 30mA - 63A 1 each
GB0440
Coefficient for per each of GB0440
Code Description Quant Units MT5380 2 pole RCCB, 230 volt A.C, 100mA - 16A 1 each
GB0441
Coefficient for per each of GB0441
Code Description Quant Units MT5381 2 pole RCCB, 230 volt A.C, 100mA - 25A 1 each
GB0442
Coefficient for per each of GB0442
Code Description Quant Units MT5382 2 pole RCCB, 230 volt A.C, 100mA - 32A 1 each
GB0443
Coefficient for per each of GB0443
Code Description Quant Units MT5383 2 pole RCCB, 230 volt A.C, 100mA - 40A 1 each
Supply of residual current circuit breaker (RCCB) double pole, sensitivity 100mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A
Supply of residual current circuit breaker (RCCB) double pole, sensitivity 30mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A
Supply of residual current circuit breaker (RCCB) double pole, sensitivity 30mA, 230 volt A.C complete with all accessories suitable tofix on a din-bar etc. as required - 40A
Supply of residual current circuit breaker (RCCB) double pole, sensitivity 30mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A
Supply of residual current circuit breaker (RCCB) double pole, sensitivity 100mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A
Supply of residual current circuit breaker (RCCB) double pole, sensitivity 100mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A
Supply of residual current circuit breaker (RCCB) double pole, sensitivity 100mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A
Supply of electronic timer switch double pole, 50Hz, sensitivity 30mA, 230 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 24hrs/24hrs
Supply of electronic timer switch double pole, 50Hz, sensitivity 30mA, 230 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 7days/24hrs
Supply of residual current circuit breaker (RCCB) double pole, sensitivity 30mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A
Supply of residual current circuit breaker (RCCB) double pole, sensitivity 30mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A
Labour and Material Coefficients (Electrical)- 2013 Page 206
Department of Engineering Services, MoWHS
GB0444
Coefficient for per each of GB0444
Code Description Quant Units MT5384 2 pole RCCB, 230 volt A.C, 100mA - 63A 1 each
GB0455
Coefficient for per each of GB0455
Code Description Quant Units MT5410 2 pole RCCB, 230 volt A.C, 300mA - 16A 1 each
GB0456
Coefficient for per each of GB0456
Code Description Quant Units MT5411 2 pole RCCB, 230 volt A.C, 300mA - 25A 1 each
GB0457
Coefficient for per each of GB0457
Code Description Quant Units MT5412 2 pole RCCB, 230 volt A.C, 300mA - 32A 1 each
GB0458
Coefficient for per each of GB0458
Code Description Quant Units MT5413 2 pole RCCB, 230 volt A.C, 300mA - 40A 1 each
GB0459
Coefficient for per each of GB0459
Code Description Quant Units MT5414 2 pole RCCB, 230 volt A.C, 300mA - 63A 1 each
GB0470
Coefficient for per each of GB0470
Code Description Quant Units MT5440 4 pole RCCB, 415 volt A.C, 30mA - 16A 1 each
GB0471
Coefficient for per each of GB0471
Code Description Quant Units MT5441 4 pole RCCB, 415 volt A.C, 30mA - 25A 1 each
GB0472
Coefficient for per each of GB0472
Code Description Quant Units MT5442 4 pole RCCB, 415 volt A.C, 30mA - 32A 1 each
GB0473
Coefficient for per each of GB0473
Code Description Quant Units MT5443 4 pole RCCB, 415 volt A.C, 30mA - 40A 1 each
GB0474
Coefficient for per each of GB0474
Code Description Quant Units MT5444 4 pole RCCB, 415 volt A.C, 30mA - 63A 1 each
Supply of residual current circuit breaker (RCCB) double pole, sensitivity 300mA, 230 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 63A
Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 30mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A
Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 30mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A
Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 30mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A
Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 30mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A
Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 30mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A
Supply of residual current circuit breaker (RCCB) double pole, sensitivity 100mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A
Supply of residual current circuit breaker (RCCB) double pole, sensitivity 300mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A
Supply of residual current circuit breaker (RCCB) double pole, sensitivity 300mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A
Supply of residual current circuit breaker (RCCB) double pole, sensitivity 300mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A
Supply of residual current circuit breaker (RCCB) double pole, sensitivity 300mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A
Labour and Material Coefficients (Electrical)- 2013 Page 207
Department of Engineering Services, MoWHS
GB0485
Coefficient for per each of GB0485
Code Description Quant Units MT5470 4 pole RCCB, 415 volt A.C, 100mA - 16A 1 each
GB0486
Coefficient for per each of GB0486
Code Description Quant Units MT5471 4 pole RCCB, 415 volt A.C, 100mA - 25A 1 each
GB0487
Coefficient for per each of GB0487
Code Description Quant Units MT5472 4 pole RCCB, 415 volt A.C, 100mA - 32A 1 each
GB0488
Coefficient for per each of GB0488
Code Description Quant Units MT5473 4 pole RCCB, 415 volt A.C, 100mA - 40A 1 each
GB0489
Coefficient for per each of GB0489
Code Description Quant Units MT5474 4 pole RCCB, 415 volt A.C, 100mA - 63A 1 each
GB0500
Coefficient for per each of GB0500
Code Description Quant Units MT5500 4 pole RCCB, 415 volt A.C, 300mA - 16A 1 each
GB0501
Coefficient for per each of GB0501
Code Description Quant Units MT5501 4 pole RCCB, 415 volt A.C, 300mA - 25A 1 each
GB0502
Coefficient for per each of GB0502
Code Description Quant Units MT5502 4 pole RCCB, 415 volt A.C, 300mA - 32A 1 each
GB0503
Coefficient for per each of GB0503
Code Description Quant Units MT5503 4 pole RCCB, 415 volt A.C, 300mA - 40A 1 each
GB0504
Coefficient for per each of GB0504
Code Description Quant Units MT5504 4 pole RCCB, 415 volt A.C, 300mA - 63A 1 each
Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 300mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A
Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 300mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A
Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 300mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A
Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 300mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A
Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 100mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A
Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 100mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A
Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 100mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A
Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 100mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A
Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 100mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A
Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 300mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A
Labour and Material Coefficients (Electrical)- 2013 Page 208
Department of Engineering Services, MoWHS
GB0515
Coefficient for per each of GB0515
Code Description Quant Units MT5525 SPN DB, 230 volt A.C, without door - 4 way 1 each
GB0516
Coefficient for per each of GB0516
Code Description Quant Units MT5526 SPN DB, 230 volt A.C, without door - 6 way 1 each
GB0517
Coefficient for per each of GB0517
Code Description Quant Units MT5527 SPN DB, 230 volt A.C, without door - 8 way 1 each
GB0518
Coefficient for per each of GB0518
Code Description Quant Units MT5528 SPN DB, 230 volt A.C, without door - 12 way 1 each
GB0519
Coefficient for per each of GB0519
Code Description Quant Units MT5529 SPN DB, 230 volt A.C, without door - 16 way 1 each
GB0521
Coefficient for per each of GB0521
Code Description Quant Units MT5531 SPN DB, 230 volt A.C, with metal door - 4 way 1 each
GB0522
Coefficient for per each of GB0522
Code Description Quant Units MT5532 SPN DB, 230 volt A.C, with metal door - 6 way 1 each
GB0523
Coefficient for per each of GB0523
Code Description Quant Units MT5533 SPN DB, 230 volt A.C, with metal door - 8 way 1 each
GB0524
Coefficient for per each of GB0524
Code Description Quant Units MT5534 SPN DB, 230 volt A.C, with metal door - 12 way 1 each
GB0525
Coefficient for per each of GB0525
Code Description Quant Units MT5535 SPN DB, 230 volt A.C, with metal door - 16 way 1 each
Supply of SPN distribution board (DIN type) with metal door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way
Supply of SPN distribution board (DIN type) with metal door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way
Supply of SPN distribution board (DIN type) with metal door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way
Supply of SPN distribution board (DIN type) with metal door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way
Supply of SPN distribution board (DIN type) with metal door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 16 way
Supply of SPN distribution board (DIN type) without door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way
Supply of SPN distribution board (DIN type) without door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way
Supply of SPN distribution board (DIN type) without door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way
Supply of SPN distribution board (DIN type) without door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way
Supply of SPN distribution board (DIN type) without door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 16 way
Labour and Material Coefficients (Electrical)- 2013 Page 209
Department of Engineering Services, MoWHS
GB0527
Coefficient for per each of GB0527
Code Description Quant Units MT5537 SPN DB, 230 volt A.C, with arcylic door - 4 way 1 each
GB0528
Coefficient for per each of GB0528
Code Description Quant Units MT5538 SPN DB, 230 volt A.C, with arcylic door - 6 way 1 each
GB0529
Coefficient for per each of GB0529
Code Description Quant Units MT5539 SPN DB, 230 volt A.C, with arcylic door - 8 way 1 each
GB0530
Coefficient for per each of GB0530
Code Description Quant Units MT5540 SPN DB, 230 volt A.C, with arcylic door - 12 way 1 each
GB0531
Coefficient for per each of GB0531
Code Description Quant Units MT5541 SPN DB, 230 volt A.C, with arcylic door - 16 way 1 each
GB0533
Coefficient for per each of GB0533
Code Description Quant Units MT5543 TPN DB, 415 volt A.C, horizontal, without door - 4 way 1 each
GB0534
Coefficient for per each of GB0534
Code Description Quant Units MT5544 TPN DB, 415 volt A.C, horizontal, without door - 6 way 1 each
GB0535
Coefficient for per each of GB0535
Code Description Quant Units MT5545 TPN DB, 415 volt A.C, horizontal, without door - 8 way 1 each
GB0536
Coefficient for per each of GB0536
Code Description Quant Units MT5546 TPN DB, 415 volt A.C, horizontal, without door - 12 way 1 each
Supply of TPN distribution board (DIN type, horizontal) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way
Supply of TPN distribution board (DIN type, horizontal) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way
Supply of SPN distribution board (DIN type) with arcylic door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way
Supply of SPN distribution board (DIN type) with arcylic door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way
Supply of SPN distribution board (DIN type) with arcylic door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way
Supply of SPN distribution board (DIN type) with arcylic door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 16 way
Supply of TPN distribution board (DIN type, horizontal) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way
Supply of TPN distribution board (DIN type, horizontal) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way
Supply of SPN distribution board (DIN type) with arcylic door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way
Labour and Material Coefficients (Electrical)- 2013 Page 210
Department of Engineering Services, MoWHS
GB0537
Coefficient for per each of GB0537
Code Description Quant Units MT5547 TPN DB, 415 volt A.C, horizontal, without door - 16 way 1 each
GB0539
Coefficient for per each of GB0539
Code Description Quant Units MT5549 TPN DB, 415 volt A.C, horizontal, with metal door - 4 way 1 each
GB0540
Coefficient for per each of GB0540
Code Description Quant Units MT5550 TPN DB, 415 volt A.C, horizontal, with metal door - 6 way 1 each
GB0541
Coefficient for per each of GB0541
Code Description Quant Units MT5551 TPN DB, 415 volt A.C, horizontal, with metal door - 8 way 1 each
GB0542
Coefficient for per each of GB0542
Code Description Quant Units MT5552 TPN DB, 415 volt A.C, horizontal, with metal door - 12 way 1 each
GB0543
Coefficient for per each of GB0543
Code Description Quant Units MT5553 TPN DB, 415 volt A.C, horizontal, with metal door - 16 way 1 each
GB0545
Coefficient for per each of GB0545
Code Description Quant Units MT5555 TPN DB, 415 volt A.C, horizontal, with arcylic door - 4 way 1 each
GB0546
Coefficient for per each of GB0546
Code Description Quant Units MT5556 TPN DB, 415 volt A.C, horizontal, with arcylic door - 6 way 1 each
Supply of TPN distribution board (DIN type, horizontal) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 16 way
Supply of TPN distribution board (DIN type, horizontal) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way
Supply of TPN distribution board (DIN type, horizontal) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way
Supply of TPN distribution board (DIN type, horizontal) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way
Supply of TPN distribution board (DIN type, horizontal) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way
Supply of TPN distribution board (DIN type, horizontal) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way
Supply of TPN distribution board (DIN type, horizontal) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 16 way
Supply of TPN distribution board (DIN type, horizontal) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way
Labour and Material Coefficients (Electrical)- 2013 Page 211
Department of Engineering Services, MoWHS
GB0547
Coefficient for per each of GB0547
Code Description Quant Units MT5557 TPN DB, 415 volt A.C, horizontal, with arcylic door - 8 way 1 each
GB0548
Coefficient for per each of GB0548
Code Description Quant Units MT5558 TPN DB, 415 volt A.C, horizontal, with arcylic door - 12 way 1 each
GB0549
Coefficient for per each of GB0549
Code Description Quant Units MT5559 TPN DB, 415 volt A.C, horizontal, with arcylic door - 16 way 1 each
GB0551
Coefficient for per each of GB0551
Code Description Quant Units MT5561 TPN DB, 415 volt A.C, vertical, without door - 4 way 1 each
GB0552
Coefficient for per each of GB0552
Code Description Quant Units MT5562 TPN DB, 415 volt A.C, vertical, without door - 6 way 1 each
GB0553
Coefficient for per each of GB0553
Code Description Quant Units MT5563 TPN DB, 415 volt A.C, vertical, without door - 8 way 1 each
GB0554
Coefficient for per each of GB0554
Code Description Quant Units MT5564 TPN DB, 415 volt A.C, vertical, without door - 12 way 1 each
GB0556
Coefficient for per each of GB0556
Code Description Quant Units MT5566 TPN DB, 415 volt A.C, vertical, with metal door - 4 way 1 each
Supply of TPN distribution board (DIN type, vertical) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way
Supply of TPN distribution board (DIN type, vertical) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way
Supply of TPN distribution board (DIN type, vertical) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way
Supply of TPN distribution board (DIN type, vertical) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way
Supply of TPN distribution board (DIN type, vertical) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way
Supply of TPN distribution board (DIN type, horizontal) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way
Supply of TPN distribution board (DIN type, horizontal) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way
Supply of TPN distribution board (DIN type, horizontal) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 16 way
Labour and Material Coefficients (Electrical)- 2013 Page 212
Department of Engineering Services, MoWHS
GB0557
Coefficient for per each of GB0557
Code Description Quant Units MT5567 TPN DB, 415 volt A.C, vertical, with metal door - 6 way 1 each
GB0558
Coefficient for per each of GB0558
Code Description Quant Units MT5568 TPN DB, 415 volt A.C, vertical, with metal door - 8 way 1 each
GB0559
Coefficient for per each of GB0559
Code Description Quant Units MT5569 TPN DB, 415 volt A.C, vertical, with metal door - 12 way 1 each
GB0561
Coefficient for per each of GB0561
Code Description Quant Units MT5571 TPN DB, 415 volt A.C, vertical, with arcylic door - 4 way 1 each
GB0562
Coefficient for per each of GB0562
Code Description Quant Units MT5572 TPN DB, 415 volt A.C, vertical, with arcylic door - 6 way 1 each
GB0563
Coefficient for per each of GB0563
Code Description Quant Units MT5573 TPN DB, 415 volt A.C, vertical, with arcylic door - 8 way 1 each
GB0564
Coefficient for per each of GB0564
Code Description Quant Units MT5574 TPN DB, 415 volt A.C, vertical, with arcylic door - 12 way 1 each
GB0575
Coefficient for per each of GB0575
Code Description Quant Units MT5116 SPN MCB, 230 volt A.C - 10A 1 each MT5610 Earth plug & Socket, DP 230 volt A.C - 10A 1 each
GB0576
Coefficient for per each of GB0576
Code Description Quant Units MT5118 SPN MCB, 230 volt A.C - 20A 1 each MT5611 Earth plug & Socket, DP 230 volt A.C - 20A 1 each
Supply of TPN distribution board (DIN type, vertical) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way
Supply of TPN distribution board (DIN type, vertical) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way
Supply of TPN distribution board (DIN type, vertical) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way
Supply of TPN distribution board (DIN type, vertical) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way
Supply of TPN distribution board (DIN type, vertical) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way
Supply of TPN distribution board (DIN type, vertical) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way
Supply of TPN distribution board (DIN type, vertical) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way
Supply of double pole metal clad commercial/industrial type plug & socket outlet with earth terminal and incoming control gear MCB etc. as required , 230 volt A.C - 10A
Supply of double pole metal clad commercial/industrial type plug & socket outlet with earth terminal and incoming control gear MCB etc. as required , 230 volt A.C - 20A
Labour and Material Coefficients (Electrical)- 2013 Page 213
Department of Engineering Services, MoWHS
GB0590
Coefficient for per each of GB0590
Code Description Quant Units MT5263 4 pole MCB, 415 volt A.C - 20A 1 each MT5620 Earth plug & Socket, 4 pole 415 volt A.C - 20A 1 each
GB0591
Coefficient for per each of GB0591
Code Description Quant Units MT5265 4 pole MCB, 415 volt A.C - 32A 1 each MT5621 Earth plug & Socket, 4 pole 415 volt A.C - 32A 1 each
GB0592
Coefficient for per each of GB0592
Code Description Quant Units MT5268 4 pole MCB, 415 volt A.C - 63A 1 each MT5622 Earth plug & Socket, 4 pole 415 volt A.C - 63A 1 each
CHAPTER 15: ERECTION/INSTALLATION
Coefficient for per each of EI0001
Code Description Quant Units LB0056 Wireman Gd.1 0.056 day LB0069 Wireman Gd.2 0.056 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.5 m
Coefficient for per each of EI0002
Code Description Quant Units LB0056 Wireman Gd.1 0.056 day LB0069 Wireman Gd.2 0.056 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 0.5 m
Coefficient for per each of EI0015
Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.5 m
1.5 sq.mm single core cable 1.1 KV grade Coefficient for per each of EI0016
Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 0.5 m
Erection of all indoor recessed type ceiling fittings/ wall fittings, GLS lamps, fixing of lamp, testing etc. as required including connection with PVC insulated copper conductor - 1 sq.mm single core cable 1.1 KV grade
EI0015
Erection of all indoor recessed type ceiling fittings/ wall fittings, GLS lamps, fixing of lamp, testing etc. as required including connection with PVC insulated copper conductor - EI0016
Supply of 4 pole metal clad commercial/industrial type plug & socket outlet with earth terminal and incoming control gear MCB etc. as required , 415 volt A.C - 63A
Erection of all indoor/outdoor surface type wall bracket (single or double)/ surface ceiling fittings GLS lamps/ bulk head GLS lamp /all types call bell / all type picture or mirror lighting luminiaries fittings with all accessories, fixing of lamp, testing etc. as required including connection with PVC insulated copper conductor - 1 sq.mm single core cable 1.1 KV grade
EI0001
Erection of all indoor/outdoor surface type wall bracket (single or double)/ surface ceiling fittings GLS lamps/ bulk head GLS lamp / all types call bell / all type picture or mirror lighting luminiaries fittings with all accessories, fixing of lamp, testing etc. as required including connection with PVC insulated copper conductor - 1.5 sq.mm single core cable 1.1 KV grade
EI0002
Supply of 4 pole metal clad commercial/industrial type plug & socket outlet with earth terminal and incoming control gear MCB etc. as required , 415 volt A.C - 32A
Supply of 4 pole metal clad commercial/industrial type plug & socket outlet with earth terminal and incoming control gear MCB etc. as required , 415 volt A.C - 20A
Labour and Material Coefficients (Electrical)- 2013 Page 214
Department of Engineering Services, MoWHS
EI0030
Coefficient for per each of EI0030
Code Description Quant Units LB0056 Wireman Gd.1 0.033 day LB0069 Wireman Gd.2 0.033 day
Coefficient for per each of EI0040
Code Description Quant Units LB0056 Wireman Gd.1 0.167 day LB0069 Wireman Gd.2 0.167 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.5 m
Coefficient for per each of EI0040
Code Description Quant Units LB0056 Wireman Gd.1 0.167 day LB0069 Wireman Gd.2 0.167 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 0.5 m
Coefficient for per each of EI0055
Code Description Quant Units LB0051 Mason Gd.2 0.167 day LB0056 Wireman Gd.1 0.167 day LB0067 Painter Gd.2 0.0417 day LB0069 Wireman Gd.2 0.375 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.9 m MT4801 M.S Coduit - 20mm x 1.6mm 0.6 m MT4891 Wooden batten - Round block 76x38mm 2 each
Coefficient for per each of EI0056
Code Description Quant Units LB0051 Mason Gd.2 0.167 day LB0056 Wireman Gd.1 0.167 day LB0067 Painter Gd.2 0.0417 day LB0069 Wireman Gd.2 0.375 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 0.9 m MT4801 M.S Coduit - 20mm x 1.6mm 0.6 m MT4891 Wooden batten - Round block 76x38mm 2 each
Installation, testing and commissioning of prewired fluorescent fittings of all pendant type complete with all accessories and tubes including supplying and fixing ball and socket arrangement suspension down rod of 19mm dia 18 SWG MS conduit upto 300mm length, painting and including wiring down rod with PVC insulated copper conductor - 1 sq.mm single core cable 1.1 KV grade
EI0055
Installation, testing and commissioning of prewired fluorescent fittings of all pendant type complete with all accessories and tubes including supplying and fixing ball and socket arrangement suspension down rod of 19mm dia 18 SWG MS conduit upto 300mm length, painting and including wiring down rod with PVC insulated copper conductor - 1.5 sq.mm single core cable 1.1 KV grade
EI0056
Installation, testing and commissioning of prewired fluorescent fittings of all surface type complete with all accessories and tubes directly on ceiling/wall as required including connection with PVC insulated copper conductor - 1 sq.mm single core cable 1.1 KV grade
EI0040
Installation, testing and commissioning of prewired fluorescent fittings of all surface type complete with all accessories and tubes directly on ceiling/wall as required including connection with PVC insulated copper conductor - 1.5 sq.mm single core cable 1.1 KV grade
EI0041
Erection / replacement for surface or recessed GLS luminiaries to make good as required - All types glass globe / shade
Labour and Material Coefficients (Electrical)- 2013 Page 215
Department of Engineering Services, MoWHS
EI0070
Coefficient for per each of EI0070
Code Description Quant Units LB0056 Wireman Gd.1 0.0167 day LB0069 Wireman Gd.2 0.0167 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.2 m MT4801 M.S Coduit - 20mm x 1.6mm 0.2 m
1 sq.mm single core cable 1.1 KV grade Coefficient for per each of EI0080
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.255 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.5 m
1.5 sq.mm single core cable 1.1 KV grade Coefficient for per each of EI0081
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 0.5 m
Coefficient for per each of EI0095
Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.8 m
Coefficient for per each of EI0096
Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 0.8 m
EI0110
Coefficient for per each of EI0110
Code Description Quant Units LB0051 Mason Gd.2 0.0104 day LB0056 Wireman Gd.1 0.0104 day LB0067 Painter Gd.2 0.0071 day LB0069 Wireman Gd.2 0.028 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.2 m MT6665 G.I Pipe heavy duty - 15mm 0.1 m
1.1 KV grade EI0095
Installation, testing and commissioning of all size ceiling fan and regulator including wiring the down rod of standard length upto 300mm with PVC insulated copper conductor - 1.5 sq.mm single core cable 1.1 KV grade
EI0096
Supplying extra down rod of G.I Pipe (heavy duty) with 2x1 sq.mm PVC insulated single core copper conductor cable, painting, cutting, and threading etc. as required - 15mm dia, 100 mm long
Providing extra down rod with 2x1 sq.mm PVC insulated single core copper conductor cable including painting as required - 20mm dia, 2x100 mm long
Installation, testing and commissioning of prewired fluorescent fittings of all recessed type complete with all accessories and tubes on ceiling including connection with PVC insulated copper conductor-EI0080
Installation, testing and commissioning of prewired fluorescent fittings of all recessed type complete with all accessories and tubes on ceiling including connection with PVC insulated copper conductor - EI0081
Installation, testing and commissioning of all size ceiling fan and regulator including wiring the down rod of standard length upto 300mm with PVC insulated copper conductor - 1 sq.mm single core cable
Labour and Material Coefficients (Electrical)- 2013 Page 216
Department of Engineering Services, MoWHS
Coefficient for per each of EI0120
Code Description Quant Units LB0051 Mason Gd.2 0.33 day LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.67 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.8 m
Coefficient for per each of EI0121
Code Description Quant Units LB0051 Mason Gd.2 0.33 day LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.67 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 0.8 m
Coefficient for per each of EI0135
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.8 m
Coefficient for per each of EI0136
Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 0.8 m
EI0150
Coefficient for per each of EI0150
Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.2 day EI0160 Coefficient for per each of EI0160
Code Description Quant Units LB0067 Painter Gd.2 0.03 day LB0069 Wireman Gd.2 0.03 day MT6682 Synthetic enamel paint 1 litre
Installation of aluminium louveres/shutters complete with a frame of all sizes in the existing opening including making good as required - Exhaust fan upto 510mm sweep
Numbering of ceiling or exhaust fan as required - Upto 510mm sweep
Installation, testing and commissioning of exhaust fan upto 510mm sweepin the existing opening including making the hole to suit the size of the indicated fan making good the damages, and connection with PVC insulated copper conductor - 1 sq.mm single core cable 1.1 KV grade
EI0135
Installation, testing and commissioning of exhaust fan upto 510mm sweepin the existing opening including making the hole to suit the size of the indicated fan making good the damages, and connection with PVC insulated copper conductor - 1.5 sq.mm single core cable 1.1 KV grade
EI0136
Installation, testing and commissioning of exhaust fan upto 450mm sweepin the existing opening including making the hole to suit the size of the indicated fan making good the damages, and connection with PVC insulated copper conductor - 1 sq.mm single core cable 1.1 KV grade
EI0120
Installation, testing and commissioning of exhaust fan upto 450mm sweepin the existing opening including making the hole to suit the size of the indicated fan making good the damages, and connection with PVC insulated copper conductor - 1.5 sq.mm single core cable 1.1 KV grade
EI0121
Labour and Material Coefficients (Electrical)- 2013 Page 217
Department of Engineering Services, MoWHS
EI0170
Coefficient for per each of EI0170
Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 3 m MT4079 PVC insulated Single Core Copper conductor (1.1KV) - 35 sq.mm 2 m MT4640 Flat type Brass Thimble - 63A 4 each MT4641 Flat type Brass Thimble - 100A 2 each MT4843 PVC Conduit - 40 mm,14SWG 0.6 m MT4844 PVC Conduit - 50 mm,14SWG 0.3 m
EI0171
Coefficient for per each of EI0171
Code Description Quant Units LB0056 Wireman Gd.1 1 day LB0069 Wireman Gd.2 1 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4 m MT4079 PVC insulated Single Core Copper conductor (1.1KV) - 35 sq.mm 3 m MT4640 Flat type Brass Thimble - 63A 4 each MT4641 Flat type Brass Thimble - 100A 2 each MT4844 PVC Conduit - 50 mm,14SWG 1 m
EI0172
Coefficient for per each of EI0172
Code Description Quant Units LB0056 Wireman Gd.1 1.25 day LB0069 Wireman Gd.2 1.25 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 13 m MT4079 PVC insulated Single Core Copper conductor (1.1KV) - 35 sq.mm 3 m MT4640 Flat type Brass Thimble - 63A 16 each MT4641 Flat type Brass Thimble - 100A 4 each MT4844 PVC Conduit - 50 mm,14SWG 3 m
EI0173
Coefficient for per each of EI0173
Code Description Quant Units LB0056 Wireman Gd.1 1.25 day LB0069 Wireman Gd.2 1.25 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 13 m MT4081 PVC insulated Single Core Copper conductor (1.1KV) - 70 sq.mm 3 m MT4640 Flat type Brass Thimble - 63A 16 each MT4642 Flat type Brass Thimble - 200A 4 each MT4844 PVC Conduit - 50 mm,14SWG 3 m
Installation, testing and commissioning of prefabricated bus bar chamber with copper bus bar complete with all accessories including connections etc. as required - 2 strips, 300/450mm length, 100A
Installation, testing and commissioning of prefabricated bus bar chamber with copper bus bar complete with all accessories including connections etc. as required - 4 strips, 300/450mm length, 100A
Installation, testing and commissioning of prefabricated bus bar chamber with copper bus bar complete with all accessories including connections etc. as required - 4 strips, 600mm length, 100A
Installation, testing and commissioning of prefabricated bus bar chamber with copper bus bar complete with all accessories including connections etc. as required - 4 strips, 300/450mm length, 200A
Labour and Material Coefficients (Electrical)- 2013 Page 218
Department of Engineering Services, MoWHS
EI0174
Coefficient for per each of EI0174
Code Description Quant Units LB0056 Wireman Gd.1 1.5 day LB0069 Wireman Gd.2 1.5 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 13 m MT4081 PVC insulated Single Core Copper conductor (1.1KV) - 70 sq.mm 3 m MT4640 Flat type Brass Thimble - 63A 16 each MT4642 Flat type Brass Thimble - 200A 4 each MT4844 PVC Conduit - 50 mm,14SWG 4 m
Coefficient for per each of EI0185
Code Description Quant Units LB0056 Wireman Gd.1 1.7 day LB0069 Wireman Gd.2 1.7 day MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 15 m MT4056 PVC insulated single core Aluminium conductor cable 1.1KV - 185 sq.mm 3 m MT4655 Flat type Aluminium Alloy Thimble - 100A 16 each MT4658 Flat type Aluminium Alloy Thimble - 300A 4 each MT4844 PVC Conduit - 50 mm,14SWG 6 m
Coefficient for per each of EI0186
Code Description Quant Units LB0056 Wireman Gd.1 1.85 day LB0069 Wireman Gd.2 1.85 day MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 20 m MT4057 PVC insulated single core Aluminium conductor cable 1.1KV - 300 sq.mm 3 m MT4655 Flat type Aluminium Alloy Thimble - 100A 24 each MT4660 Flat type Aluminium Alloy Thimble - 400A 4 each MT4844 PVC Conduit - 50 mm,14SWG 8 m
Coefficient for per each of EI0187
Code Description Quant Units LB0056 Wireman Gd.1 2 day LB0069 Wireman Gd.2 2 day MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 20 m MT4058 PVC insulated single core Aluminium conductor cable 1.1KV - 600 sq.mm 3 m MT4655 Flat type Aluminium Alloy Thimble - 100A 24 each MT4662 Flat type Aluminium Alloy Thimble - 600A 4 each MT4844 PVC Conduit - 50 mm,14SWG 8 m
Coefficient for per each of EI0188
Code Description Quant Units LB0056 Wireman Gd.1 1.95 day LB0069 Wireman Gd.2 1.95 day
Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete with all accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 600mm length, 600A
EI0187
Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete with all accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 900mm length, 400A
EI0188
Installation, testing and commissioning of prefabricated bus bar chamber with copper bus bar complete with all accessories including connections etc. as required - 4 strips, 600mm length, 200A
Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete all with accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 600mm length, 300A
EI0185
Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete with all accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 600mm length, 400A
EI0186
Labour and Material Coefficients (Electrical)- 2013 Page 219
Department of Engineering Services, MoWHS
MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 22 m MT4057 PVC insulated single core Aluminium conductor cable 1.1KV - 300 sq.mm 3.5 m MT4655 Flat type Aluminium Alloy Thimble - 100A 24 each MT4660 Flat type Aluminium Alloy Thimble - 400A 4 each MT4844 PVC Conduit - 50 mm,14SWG 9 m
Coefficient for per each of EI0189
Code Description Quant Units LB0056 Wireman Gd.1 2.2 day LB0069 Wireman Gd.2 2.2 day MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 22 m MT4058 PVC insulated single core Aluminium conductor cable 1.1KV - 600 sq.mm 3.5 m MT4655 Flat type Aluminium Alloy Thimble - 100A 24 each MT4662 Flat type Aluminium Alloy Thimble - 600A 4 each MT4844 PVC Conduit - 50 mm,14SWG 9 m
Coefficient for per each of EI0190
Code Description Quant Units LB0056 Wireman Gd.1 2.5 day LB0069 Wireman Gd.2 2.5 day MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 25 m MT4059 PVC insulated single core Aluminium conductor cable 1.1KV - 800 sq.mm 3.5 m MT4655 Flat type Aluminium Alloy Thimble - 100A 32 each MT4665 Flat type Aluminium Alloy Thimble - 800A 4 each MT4844 PVC Conduit - 50 mm,14SWG 10 m
Coefficient for per each of EI0191
Code Description Quant Units LB0056 Wireman Gd.1 2 day LB0069 Wireman Gd.2 2 day MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 24 m MT4057 PVC insulated single core Aluminium conductor cable 1.1KV - 300 sq.mm 4 m MT4655 Flat type Aluminium Alloy Thimble - 100A 24 each MT4660 Flat type Aluminium Alloy Thimble - 400A 4 each MT4844 PVC Conduit - 50 mm,14SWG 9 m
Coefficient for per each of EI0192
Code Description Quant Units LB0056 Wireman Gd.1 2.4 day LB0069 Wireman Gd.2 2.4 day MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 24 m MT4058 PVC insulated single core Aluminium conductor cable 1.1KV - 600 sq.mm 4 m MT4655 Flat type Aluminium Alloy Thimble - 100A 24 each MT4662 Flat type Aluminium Alloy Thimble - 600A 4 each MT4844 PVC Conduit - 50 mm,14SWG 9 m
Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete with all accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 1350mm length, 400A
EI0191
Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete with all accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 1350mm length, 600A
EI0192
Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete with all accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 900mm length, 600A
EI0189
Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete with all accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 900mm length, 800A
EI0190
Labour and Material Coefficients (Electrical)- 2013 Page 220
Department of Engineering Services, MoWHS
Coefficient for per each of EI0193
Code Description Quant Units LB0056 Wireman Gd.1 2.7 day LB0069 Wireman Gd.2 2.7 day MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 24 m MT4059 PVC insulated single core Aluminium conductor cable 1.1KV - 800 sq.mm 4 m MT4655 Flat type Aluminium Alloy Thimble - 100A 32 each MT4665 Flat type Aluminium Alloy Thimble - 800A 4 each MT4844 PVC Conduit - 50 mm,14SWG 11 m
Coefficient for per each of EI0205
Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4678 Ferrule type brass thimble - 20A 4 each
Coefficient for per each of EI0206
Code Description Quant Units LB0056 Wireman Gd.1 0.11 day LB0069 Wireman Gd.2 0.11 day MT4680 Ferrule type brass thimble - 32A 4 each
Coefficient for per each of EI0207
Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4683 Ferrule type brass thimble - 63A 4 each
Coefficient for per each of EI0220
Code Description Quant Units LB0056 Wireman Gd.1 0.1428 day LB0069 Wireman Gd.2 0.1428 day MT4685 Ferrule type brass thimble - 125A 4 each
Coefficient for per each of EI0230
Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4680 Ferrule type brass thimble - 32A 4 each
Installation, testing and commissioning of TPN/four pole steel encloser/panel mounting front drive switch fuse unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 125A, 415V
EI0220
Installation, testing and commissioning of TP switch fuse unit front drive four/ miniature circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 32A, 415V
EI0230
Installation, testing and commissioning of TPN steel encloser switch fuse unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 32A, 415V
EI0206
Installation, testing and commissioning of TPN steel encloser switch fuse unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 63A, 415V
EI0207
Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete with all accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 1350mm length, 800A
EI0193
Installation, testing and commissioning of TPN steel encloser switch fuse unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 20A, 415V
EI0205
Labour and Material Coefficients (Electrical)- 2013 Page 221
Department of Engineering Services, MoWHS
Coefficient for per each of EI0240
Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4706 Ferrule type aluminium alloy thimble - 125A 4 each
Coefficient for per each of EI0250
Code Description Quant Units LB0056 Wireman Gd.1 1 day LB0069 Wireman Gd.2 1 day MT4665 Flat type Aluminium Alloy Thimble - 800A 4 each
Coefficient for per each of EI0260
Code Description Quant Units LB0056 Wireman Gd.1 0.11 day LB0069 Wireman Gd.2 0.11 day MT4640 Flat type Brass Thimble - 63A 4 each
Coefficient for per each of EI0270
Code Description Quant Units LB0056 Wireman Gd.1 0.167 day LB0069 Wireman Gd.2 0.167 day MT4686 Ferrule type brass thimble - 200A 4 each
Coefficient for per each of EI0271
Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4659 Flat type Aluminium Alloy Thimble - 315A 4 each
Coefficient for per each of EI0272
Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4661 Flat type Aluminium Alloy Thimble - 500A 4 each
Installation, testing and commissioning of TPN steel encloser fuse switch unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 315A, 415V
EI0271
Installation, testing and commissioning of TPN steel encloser fuse switch unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panelboard including drilling holes, connections etc. as required - 500A, 415V
EI0272
Installation, testing and commissioning of TP switch fuse unit front drive/ miniature circuit breaker/ moulded case circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. required - 63A, 415V
EI0260
Installation, testing and commissioning of TPN steel encloser fuse switch unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 200A, 415V
EI0270
Installation, testing and commissioning of TP switch fuse unit front drive/ moulded case circuit breaker (DIN type) breaking capacity 16/25K complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 415V
EI0240
Installation, testing and commissioning of TP switch fuse unit front drive/ miniature circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubicle control panel board including drilling holes, connections etc. as required - 800A, 415V
EI0250
Labour and Material Coefficients (Electrical)- 2013 Page 222
Department of Engineering Services, MoWHS
Coefficient for per each of EI0273
Code Description Quant Units LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 0.75 day MT4663 Flat type Aluminium Alloy Thimble - 630A 4 each
Coefficient for per each of EI0285
Code Description Quant Units LB0056 Wireman Gd.1 0.2 day LB0069 Wireman Gd.2 0.2 day MT4643 Flat type Brass Thimble - 250A 4 each
Coefficient for per each of EI0286
Code Description Quant Units LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4660 Flat type Aluminium Alloy Thimble - 400A 4 each
Coefficient for per each of EI0300
Code Description Quant Units LB0056 Wireman Gd.1 1 day LB0069 Wireman Gd.2 1 day MT4664 Flat type Aluminium Alloy Thimble - 750A 4 each
Coefficient for per each of EI0301
Code Description Quant Units LB0056 Wireman Gd.1 1 day LB0069 Wireman Gd.2 1 day MT4665 Flat type Aluminium Alloy Thimble - 800A 4 each
Coefficient for per each of EI0315
Code Description Quant Units LB0056 Wireman Gd.1 0.2 day LB0069 Wireman Gd.2 0.2 day MT4660 Flat type Aluminium Alloy Thimble - 400A 4 each
Installation, testing and commissioning of TPN steel encloser fuse switch unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 630A, 415V
EI0273
Installation, testing and commissioning of TPN/four pole steel encloser/panel mounting front drive fuse switch unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 250A, 415V
EI0285
Installation, testing and commissioning of TPN/four pole steel encloser/panel mounting front drive fuse switch unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 400A, 415V
EI0286
Installation, testing and commissioning of TPN/four pole steel encloser fuse switch unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 750A, 415V
EI0300
Installation, testing and commissioning of TPN/four pole steel encloser fuse switch unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 800A, 415V
EI0301
Installation, testing and commissioning of TP fuse switch fuse unit front drive complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 400A, 415V
EI0315
Labour and Material Coefficients (Electrical)- 2013 Page 223
Department of Engineering Services, MoWHS
Coefficient for per each of EI0325
Code Description Quant Units LB0056 Wireman Gd.1 0.1428 day LB0069 Wireman Gd.2 0.1428 day MT4657 Flat type Aluminium Alloy Thimble - 250A 4 each
Coefficient for per each of EI0335
Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4678 Ferrule type brass thimble - 20A 4 each
Coefficient for per each of EI0336
Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4679 Ferrule type brass thimble - 25A 4 each
Coefficient for per each of EI0337
Code Description Quant Units LB0056 Wireman Gd.1 0.11 day LB0069 Wireman Gd.2 0.11 day MT4680 Ferrule type brass thimble - 32A 4 each
Coefficient for per each of EI0338
Code Description Quant Units LB0056 Wireman Gd.1 0.11 day LB0069 Wireman Gd.2 0.11 day MT4681 Ferrule type brass thimble - 40A 4 each
Coefficient for per each of EI0339
Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4682 Ferrule type brass thimble - 50A 4 each
Installation, testing and commissioning of TP fuse switch unit/ moulded case circuit breaker (DIN type) breaking capacity 36K complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 250A, 415V
EI0325
Installation, testing and commissioning of TPN/four pole miniature circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel boardincluding drilling holes, connections etc. as required - 20A, 415V
EI0335
Installation, testing and commissioning of TPN/four pole miniature circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel boardincluding drilling holes, connections etc. as required - 25A, 415V
EI0336
Installation, testing and commissioning of TPN/four pole miniature circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 32A, 415V
EI0337
Installation, testing and commissioning of TPN/four pole miniature circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 40A, 415V
EI0338
Installation, testing and commissioning of TPN/four pole miniature circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 50A, 415V
EI0339
Labour and Material Coefficients (Electrical)- 2013 Page 224
Department of Engineering Services, MoWHS
Coefficient for per each of EI0340
Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4683 Ferrule type brass thimble - 50A 4 each
Coefficient for per each of EI0350
Code Description Quant Units LB0056 Wireman Gd.1 0.09 day LB0069 Wireman Gd.2 0.09 day MT4675 Ferrule type brass thimble - 6A 4 each
Coefficient for per each of EI0351
Code Description Quant Units LB0056 Wireman Gd.1 0.09 day LB0069 Wireman Gd.2 0.09 day MT4676 Ferrule type brass thimble - 10A 4 each
Coefficient for per each of EI0352
Code Description Quant Units LB0056 Wireman Gd.1 0.09 day LB0069 Wireman Gd.2 0.09 day MT4677 Ferrule type brass thimble - 16A 4 each
Coefficient for per each of EI0353
Code Description Quant Units LB0056 Wireman Gd.1 0.09 day LB0069 Wireman Gd.2 0.09 day MT4678 Ferrule type brass thimble - 20A 4 each
Coefficient for per each of EI0354
Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4679 Ferrule type brass thimble - 25A 4 each
Coefficient for per each of EI0355
Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4680 Ferrule type brass thimble - 32A 4 each
Installation, testing and commissioning of TPN/four pole miniature circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 63A, 415V
EI0340
Installation, testing and commissioning of TP miniature circuit breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 6A, 415V
EI0350
Installation, testing and commissioning of TP miniature circuit breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 10A, 415V
EI0351
Installation, testing and commissioning of TP miniature circuit breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 16A, 415V
EI0352
Installation, testing and commissioning of TP miniature circuit breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 20A, 415V
EI0353
Installation, testing and commissioning of TP miniature circuit breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 25A, 415V
EI0354
Installation, testing and commissioning of TP miniature circuit breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 32A, 415V
EI0355
Labour and Material Coefficients (Electrical)- 2013 Page 225
Department of Engineering Services, MoWHS
Coefficient for per each of EI0365
Code Description Quant Units LB0056 Wireman Gd.1 0.09 day LB0069 Wireman Gd.2 0.09 day MT4681 Ferrule type brass thimble - 40A 4 each
Coefficient for per each of EI0366
Code Description Quant Units LB0056 Wireman Gd.1 0.09 day LB0069 Wireman Gd.2 0.09 day MT4682 Ferrule type brass thimble - 50A 4 each
Coefficient for per each of EI0367
Code Description Quant Units LB0056 Wireman Gd.1 0.11 day LB0069 Wireman Gd.2 0.11 day MT4683 Ferrule type brass thimble - 63A 4 each
Coefficient for per each of EI0380
Code Description Quant Units LB0056 Wireman Gd.1 0.09 day LB0069 Wireman Gd.2 0.09 day MT4675 Ferrule type brass thimble - 6A 1 each MT4676 Ferrule type brass thimble - 10A 1 each MT4677 Ferrule type brass thimble - 16A 1 each MT4678 Ferrule type brass thimble - 20A 1 each
Coefficient for per each of EI0390
Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4679 Ferrule type brass thimble - 25A 1.33 each MT4680 Ferrule type brass thimble - 32A 1.33 each MT4681 Ferrule type brass thimble - 40A 1.33 each
Coefficient for per each of EI0400
Code Description Quant Units LB0056 Wireman Gd.1 0.11 day LB0069 Wireman Gd.2 0.11 day MT4682 Ferrule type brass thimble - 50A 2 each MT4683 Ferrule type brass thimble - 63A 2 each
Installation, testing and commissioning of TP miniature circuit/ isolator breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 40A, 415V
EI0365
Installation, testing and commissioning of TP miniature circuit/ isolator breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 50A, 415V
EI0366
Installation, testing and commissioning of TP miniature circuit/ isolator breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 63A, 415V
EI0367
drilling holes, connections etc. as required - 6/10/16/20A
Installation, testing and commissioning of SPN/DP miniature circuit breaker DIN type complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including EI0380
Installation, testing and commissioning of SPN/DP miniature circuit breaker DIN type complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 25/32/40A
EI0390
Installation, testing and commissioning of SPN/DP miniature circuit breaker/ isolator DIN type complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 50/63A
EI0400
Labour and Material Coefficients (Electrical)- 2013 Page 226
Department of Engineering Services, MoWHS
Coefficient for per each of EI0410
Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4702 Ferrule type aluminium alloy thimble - 50A 4 each
Coefficient for per each of EI0411
Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4703 Ferrule type aluminium alloy thimble - 63A 4 each
Coefficient for per each of EI0425
Code Description Quant Units LB0056 Wireman Gd.1 0.1428 day LB0069 Wireman Gd.2 0.1428 day MT4705 Ferrule type aluminium alloy thimble - 100A 4 each
Coefficient for per each of EI0426
Code Description Quant Units LB0056 Wireman Gd.1 0.1428 day LB0069 Wireman Gd.2 0.1428 day MT4706 Ferrule type aluminium alloy thimble - 125A 4 each
Coefficient for per each of EI0440
Code Description Quant Units LB0056 Wireman Gd.1 0.1667 day LB0069 Wireman Gd.2 0.1667 day MT4709 Ferrule type aluminium alloy thimble - 160A 4 each
Coefficient for per each of EI0450
Code Description Quant Units LB0056 Wireman Gd.1 0.2 day LB0069 Wireman Gd.2 0.2 day MT4657 Flat type Aluminium Alloy Thimble - 250A 4 each
Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 16/25K complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 50A, 415V
EI0410
Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 16/25K complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 63A, 415V
EI0411
Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 16/25/36K/earth leakage module complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as 100A, 415V
EI0425
Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 16/25/36K/earth leakage module complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as 125A, 415V
EI0426
Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 36K/earth leakage module complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as 160A, 415V
EI0440
Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 36/70K/earth leakage module complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as 250A, 415V
EI0450
Labour and Material Coefficients (Electrical)- 2013 Page 227
Department of Engineering Services, MoWHS
Coefficient for per each of EI0460
Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4660 Flat type Aluminium Alloy Thimble - 400A 4 each
Coefficient for per each of EI0461
Code Description Quant Units LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 0.75 day MT4663 Flat type Aluminium Alloy Thimble - 630A 4 each
Coefficient for per each of EI0475
Code Description Quant Units LB0056 Wireman Gd.1 1 day LB0069 Wireman Gd.2 1 day MT4665 Flat type Aluminium Alloy Thimble - 800A 4 each
Coefficient for per each of EI0485
Code Description Quant Units LB0056 Wireman Gd.1 0.1428 day LB0069 Wireman Gd.2 0.1428 day MT4709 Ferrule type aluminium alloy thimble - 160A 4 each
Coefficient for per each of EI0495
Code Description Quant Units LB0056 Wireman Gd.1 0.1742 day LB0069 Wireman Gd.2 0.1742 day MT4675 Ferrule type brass thimble - 6A 1.33 each MT4676 Ferrule type brass thimble - 10A 1.33 each MT4677 Ferrule type brass thimble - 16A 2.33 each MT4679 Ferrule type brass thimble - 25A 1 each
Coefficient for per each of EI0505
Code Description Quant Units LB0056 Wireman Gd.1 0.202 day LB0069 Wireman Gd.2 0.202 day
Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 70K/earth leakage module complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as 400A, 415V
EI0460
Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 70K/earth leakage module complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as 630A, 415V
EI0461
Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 70K complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 800A, 415V
EI0475
Installation, testing and commissioning of TP moulded case circuit breaker (DIN type) breaking capacity 36K complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 160A, 415V
EI0485
Installation, testing and commissioning of SPN DB (DIN type, horizontal/vertical) with no door, metal door or arcylic door (double/single door) complete with all accessories to accommodate incomingRCCB DP 16/25A sensitivity 30/100/300mA and outgoing SP MCB 6/10/16A on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 4 way
EI0495
Installation, testing and commissioning of SPN DB (DIN type, horizontal/vertical) with no door, metal door or arcylic door (double/single door) complete with all accessories to accommodate incomingRCCB DP 32/40A sensitivity 30/100/300mA and outgoing SP MCB 6/10/16A on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 8 way
EI0505
Labour and Material Coefficients (Electrical)- 2013 Page 228
Department of Engineering Services, MoWHS
MT4675 Ferrule type brass thimble - 6A 2.66 each MT4676 Ferrule type brass thimble - 10A 2.66 each MT4677 Ferrule type brass thimble - 16A 2.66 each MT4680 Ferrule type brass thimble - 32A 1 each MT4681 Ferrule type brass thimble - 40A 1 each
Coefficient for per each of EI0515
Code Description Quant Units LB0056 Wireman Gd.1 0.2428 day LB0069 Wireman Gd.2 0.2428 day MT4675 Ferrule type brass thimble - 6A 4 each MT4676 Ferrule type brass thimble - 10A 4 each MT4677 Ferrule type brass thimble - 16A 4 each MT4683 Ferrule type brass thimble - 63A 2 each
Coefficient for per each of EI0525
Code Description Quant Units LB0056 Wireman Gd.1 0.225 day LB0069 Wireman Gd.2 0.225 day MT4675 Ferrule type brass thimble - 6A 4 each MT4676 Ferrule type brass thimble - 10A 4 each MT4677 Ferrule type brass thimble - 16A 4 each MT4680 Ferrule type brass thimble - 32A 4 each
Coefficient for per each of EI0535
Code Description Quant Units LB0056 Wireman Gd.1 0.202 day LB0069 Wireman Gd.2 0.202 day MT4675 Ferrule type brass thimble - 6A 6 each MT4676 Ferrule type brass thimble - 10A 6 each MT4677 Ferrule type brass thimble - 16A 6 each MT4683 Ferrule type brass thimble - 63A 4 each
Coefficient for per each of EI0545
Code Description Quant Units LB0056 Wireman Gd.1 0.268 day LB0069 Wireman Gd.2 0.268 day MT4675 Ferrule type brass thimble - 6A 8 each MT4676 Ferrule type brass thimble - 10A 8 each MT4677 Ferrule type brass thimble - 16A 8 each MT4680 Ferrule type brass thimble - 32A 2 each MT4684 Ferrule type brass thimble - 100A 2 each
Installation, testing and commissioning of SPN DB (DIN type, horizontal/vertical) with no door, metal door or arcylic door (double/single door) complete with all accessories to accommodate incomingRCCB DP 63A sensitivity 30/100/300mA and outgoing SP MCB 6/10/16A on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 12 way
EI0515
Installation, testing and commissioning of TPN DB (DIN type, horizontal/vertical) with no door, metal door or arcylic door (double/single door) complete with all accessories to accommodate incomingRCCB FP 16/25/32A sensitivity 30/100/300mA and outgoing SP MCB 6/10/16A on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 4 way
Installation, testing and commissioning of TPN DB (DIN type, horizontal/vertical) with no door, metal door or arcylic door (double/single door) complete with all accessories to accommodate incomingRCCB FP 40/63A sensitivity 30/100/300mA and outgoing SP MCB 6/10/16A on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 6 way
EI0525
EI0535
Installation, testing and commissioning of TPN DB (DIN type, horizontal/vertical) with no door, metal door or arcylic door (double/single door) complete with all accessories to accommodate incomingRCCB/ELCB/RCBO FP 100A sensitivity 30/100/300mA and outgoing SP MCB 6/10/16A on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 8 way
EI0545
Labour and Material Coefficients (Electrical)- 2013 Page 229
Department of Engineering Services, MoWHS
Coefficient for per each of EI0555
Code Description Quant Units LB0056 Wireman Gd.1 0.417 day LB0069 Wireman Gd.2 0.417 day MT4675 Ferrule type brass thimble - 6A 12 each MT4676 Ferrule type brass thimble - 10A 12 each MT4677 Ferrule type brass thimble - 16A 12 each MT4684 Ferrule type brass thimble - 100A 2 each MT4685 Ferrule type brass thimble - 125A 2 each
Coefficient for per each of EI0565
Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4677 Ferrule type brass thimble - 16A 2 each MT4680 Ferrule type brass thimble - 32A 2 each
Coefficient for per each of EI0575
Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4676 Ferrule type brass thimble - 10A 2 each MT4678 Ferrule type brass thimble - 20A 2 each
Coefficient for per each of EI0576
Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4678 Ferrule type brass thimble - 20A 4 each
Coefficient for per each of EI0577
Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4680 Ferrule type brass thimble - 32A 4 each
Installation, testing and commissioning of DP trimer switch assembly in a case complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board recessed including drilling holes, connections etc. as required - Adjustment range either 24/24hrs or 7days/24hrs
EI0565
Installation, testing and commissioning of metal clad commercial/industrial type plug& socket complete with all accessories to accommodate on/in surface or recessed including drilling holes, connections etc. as required - DP, 10/20A with earth terminal and incoming control gear DP MCB 10/20A
EI0575
Installation, testing and commissioning of metal clad commercial/industrial type plug& socket complete with all accessories to accommodate on/in surface or recessed including drilling holes, connections etc. as required - 4 pole 20A with earth terminal and incoming control gear 4 pole MCB 20A
EI0576
Installation, testing and commissioning of metal clad commercial/industrial type plug& socket complete with all accessories to accommodate on/in surface or recessed including drilling holes, connections etc. as required - 4 pole 32A with earth terminal and incoming control gear 4 pole MCB 32A
EI0577
Installation, testing and commissioning of TPN DB (DIN type, horizontal/vertical) with no door, metal door or arcylic door (double/single door) complete with all accessories to accommodate incomingRCCB/ELCB/RCBO FP 125A sensitivity 30/100/300mA and outgoing SP MCB 6/10/16A on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 12 way
EI0555
Labour and Material Coefficients (Electrical)- 2013 Page 230
Department of Engineering Services, MoWHS
Coefficient for per each of EI0578
Code Description Quant Units LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 0.75 day MT4683 Ferrule type brass thimble - 63A 4 each
Coefficient for per sq.m of EI0590
Code Description Quant Units LB0032 Blacksmith (metal-worker) 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT6635 Rolled Steel Section 250MPa - Angles 18 kg MT6637 Rolled Steel Section 250MPa - Flats 6.6 kg
Coefficient for per cu.m of EI0600
Code Description Quant Units LB0032 Blacksmith (metal-worker) 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT6635 Rolled Steel Section 250MPa - Angles 80 kg MT6637 Rolled Steel Section 250MPa - Flats 15.83 kg MT6650 Sheet (250 MPa) - 1mm 59.45 kg
Coefficient for per each of EI0610
Code Description Quant Units LB0056 Wireman Gd.1 0.08 day LB0069 Wireman Gd.2 0.08 day MT6651 Sheet (250 MPa) - 2mm 0.432 kg
CHAPTER 16: EARTHING
Coefficient for per each of ET0001
Code Description Quant Units LB0036 Mason Gd.1 0.11417 day LB0051 Mason Gd.2 0.04654 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day LB0077 Labourer 0.53343 day MT6510 Plate - GI Plate, 600x600x6mm 1 each MT6555 Accessories - Charcoal 96 kg MT6556 Accessories - Salt 5 kg
Installation, testing and commissioning of metal clad commercial/industrial type plug& socket complete with all accessories to accommodate on/in surface or recessed including drilling holes, connections etc. as required - 4 pole 63A with earth terminal and incoming control gear 4 pole MCB 63A
EI0578
Providing and fixing of prefabricated panel board with minimum 50x50x6mm angle iron frame work with horizontal and vertical intermidiate members of flat iron 40x6mm for mounting of switch gears incoming/ outgoing bus bar chambers including drilling holes, painting, grouting etc. as required - mounted fixed type metal board of welded construction
EI0590
Providing and fixing of prefabricated panel board with minimum 50x50x6mm angle iron frame work with horizontal and vertical intermidiate members of flat iron 40x6mm and 24 SWG sheet cover for mountingof switch gears incoming/ outgoing bus bars including drilling holes, insulator, painting, denting, grouting etc. as required - Floor mounted cubical control panel board of welded construction
EI0600
Providing and fixing medium volt danger notice plate made of mild steel and painted with vitreous enamelled white paint on both sides, and with inscription in signal red colour on front side as required on prefabricated MS surface/ MS cubical control panel board on surface including drilling holes etc. as required - 200x150x2mm
EI0610
Providing and fixing of earthing including all accessories, machinery enclosure, C.I cover plate having locking arrangement, watering pipe with excavation and refilling work including charcoal or coke and salt complete as required as per standard earthing drawing - With G.I earth plate 600x600x6mm
ET0001
Labour and Material Coefficients (Electrical)- 2013 Page 231
Department of Engineering Services, MoWHS
MT6604 Sand 0.04694 cu.m MT6666 G.I Pipe heavy duty - 20mm 2.7 m MT6680 Bricks 2nd class 0.05588 1000# MT6681 Grey Cement 0.01543 tonne MT6684 C.I. Manhole Cover with frame, 300 x 300mm inside size 1 each
Coefficient for per each of ET0002
Code Description Quant Units LB0036 Mason Gd.1 0.11417 day LB0051 Mason Gd.2 0.04654 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day LB0077 Labourer 0.53343 day MT6511 Plate - Copper Plate, 600x600x3mm 1 each MT6555 Accessories - Charcoal 96 kg MT6556 Accessories - Salt 5 kg MT6604 Sand 0.04694 cu.m MT6666 G.I Pipe heavy duty - 20mm 2.7 m MT6680 Bricks 2nd class 0.05588 1000# MT6681 Grey Cement 0.01543 tonne MT6684 C.I. Manhole Cover with frame, 300 x 300mm inside size 1 each
ET0015
Coefficient for per m of ET0015
Code Description Quant Units LB0056 Wireman Gd.1 0.01667 day LB0069 Wireman Gd.2 0.01667 day LB0077 Labourer 0.15876 day MT6530 Wire - GI, 4mm dia (8swg) 1 m MT6665 G.I Pipe heavy duty - 15mm 1 m
ET0016
Coefficient for per m of ET0016
Code Description Quant Units LB0056 Wireman Gd.1 0.01667 day LB0069 Wireman Gd.2 0.01667 day LB0077 Labourer 0.15876 day MT6536 Wire - Copper, 4mm dia (8swg) 1 m MT6665 G.I Pipe heavy duty - 15mm 1 m
ET0030
Coefficient for per m of ET0030
Code Description Quant Units LB0051 Mason Gd.2 0.0325 day LB0056 Wireman Gd.1 0.015 day LB0069 Wireman Gd.2 0.0475 day MT6530 Wire - GI, 4mm dia (8swg) 1 m
ET0031
Coefficient for per m of ET0031
Code Description Quant Units LB0051 Mason Gd.2 0.0325 day
Providing and fixing of earthing including all accessories, machinery enclosure, C.I cover plate having locking arrangement, watering pipe with excavation and refilling work including charcoal or coke and salt complete as required as per standard earthing drawing - With copper earth plate 600x600x3mm
ET0002
Providing and laying earth connection from earth electrodes in 15mm dia G.I pipe from earth electrodes as required as per guidence of standard earthing drawing - With 4.06mm dia (8SWG) G.I wire
Providing and laying earth connection from earth electrodes in 15mm dia G.I pipe from earth electrodes as required as per guidence of standard earthing drawing - With 4.06mm dia (8SWG) copper wire
Providing and fixing of wire on surface or in recessed for loop earthing as required - With 4.06mm dia (8SWG) G.I wire
Providing and fixing of wire on surface or in recessed for loop earthing as required - With 4.06mm dia (8SWG) copper wire
Labour and Material Coefficients (Electrical)- 2013 Page 232
Department of Engineering Services, MoWHS
LB0056 Wireman Gd.1 0.015 day LB0069 Wireman Gd.2 0.0475 day MT6536 Wire - Copper, 4mm dia (8swg) 1 m
ET0045
Coefficient for per m of ET0045
Code Description Quant Units LB0056 Wireman Gd.1 0.00417 day LB0069 Wireman Gd.2 0.00417 day LB0077 Labourer 0.05292 day MT6530 Wire - GI, 4mm dia (8swg) 1 m
ET0046
Coefficient for per m of ET0046
Code Description Quant Units LB0056 Wireman Gd.1 0.00417 day LB0069 Wireman Gd.2 0.00417 day LB0075 Labourer 0.5292 day MT6536 Wire - Copper, 4mm dia (8swg) 1 m
ET0060
Coefficient for per m of ET0060
Code Description Quant Units LB0056 Wireman Gd.1 0.0044 day LB0069 Wireman Gd.2 0.0044 day LB0077 Labourer 0.05292 day MT6533 Wire - G.I, 4.88mm dia (6SWG) 1 m
ET0061
Coefficient for per m of ET0061
Code Description Quant Units LB0056 Wireman Gd.1 0.0044 day LB0069 Wireman Gd.2 0.0044 day LB0077 Labourer 0.05292 day MT6538 Wire - Copper, 4.88mm dia (6SWG) 1 m
ET0075
Coefficient for per m of ET0075
Code Description Quant Units LB0056 Wireman Gd.1 0.0055 day LB0069 Wireman Gd.2 0.0055 day LB0077 Labourer 0.05292 day MT6517 Strip - GI Tape\Strip 25x4 mm 1 m
ET0076
Coefficient for per m of ET0076
Code Description Quant Units LB0056 Wireman Gd.1 0.0055 day LB0069 Wireman Gd.2 0.0055 day LB0077 Labourer 0.05292 day MT6519 Strip - Copper Tape\Strip 25x4 1 m
Providing and laying of wire at 0.5m below ground level for conductor earth electrodes including soldering etc. as required - With 4.06mm dia (8SWG) G.I wire
Providing and laying of wire at 0.5m below ground level for conductor earth electrodes including soldering etc. as required - With 4.06mm dia (8SWG) copper wire
Providing and laying of wire at 0.5m below ground level for conductor earth electrodes including soldering etc. as required - With 4.88mm dia (6SWG) G.I wire
Providing and laying of wire at 0.5m below ground level for conductor earth electrodes including soldering etc. as required - With 4.88mm dia (6SWG) copper wire
Providing and laying of metal strip at 0.5m below ground level for as strip earth electrodes including soldering etc. as required - 25x4mm G.I strip
Providing and laying of metal strip at 0.5m below ground level for as strip earth electrodes including soldering etc. as required - 25x4mm copper strip
Labour and Material Coefficients (Electrical)- 2013 Page 233
Department of Engineering Services, MoWHS
ET0077
Coefficient for per m of ET0077
Code Description Quant Units LB0056 Wireman Gd.1 0.0067 day LB0069 Wireman Gd.2 0.0067 day LB0077 Labourer 0.05292 day MT6518 Strip - GI Tape\Strip 25x6 mm 1 m
ET0090
Coefficient for per m of ET0090
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day LB0077 Labourer 0.05292 day MT6517 Strip - GI Tape\Strip 25x4 mm 1 m MT6669 G.I Pipe heavy duty - 40mm 1 m
ET0091
Coefficient for per m of ET0091
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day LB0077 Labourer 0.05292 day MT6519 Strip - Copper Tape\Strip 25x4 1 m MT6669 G.I Pipe heavy duty - 40mm 1 m
ET0105
Coefficient for per m of ET0105
Code Description Quant Units LB0051 Mason Gd.2 0.025 day LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.075 day MT6517 Strip - GI Tape\Strip 25x4 mm 1 m
ET0106
Coefficient for per m of ET0106
Code Description Quant Units LB0051 Mason Gd.2 0.025 day LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.075 day MT6519 Strip - Copper Tape\Strip 25x4 1 m
ET0120
Coefficient for per m of ET0120
Code Description Quant UnitsLB0056 Wireman Gd.1 0.0044 dayLB0069 Wireman Gd.2 0.0044 dayLB0077 Labourer 0.05292 day
MT6534 Wire - 2.032 mm dia.(14SWG) bare G.I 1 m
Providing and laying of metal strip on surface or in recessed for earth connections/loop earthing as required - 25x4mm G.I strip
Providing and laying of metal strip on surface or in recessed for earth connections/loop earthing as required - 25x4mm copper strip
Providing and laying of metal strip in 40mm dia G.I pipe at 0.5m below ground level from earth electrodes including soldering etc. as required - 25x4mm G.I strip
Providing and laying of metal strip at 0.5m below ground level for as strip earth electrodes including soldering etc. as required - 25x6mm G.I strip
Providing and laying of metal strip in 40mm dia G.I pipe at 0.5m below ground level from earth electrodes including soldering etc. as required - 25x4mm copper strip
Providing and drawing wire for loop earthing in existing surface/ recessed PVC/MS/ steel conduit or casing capping or wooden batten along with other wires as required - 2.032mm (14SWG) G.I wire
Labour and Material Coefficients (Electrical)- 2013 Page 234
Department of Engineering Services, MoWHS
ET0121
Coefficient for per m of ET0121
Code Description Quant UnitsLB0056 Wireman Gd.1 0.0044 dayLB0069 Wireman Gd.2 0.0044 dayLB0077 Labourer 0.05292 day
MT6539 Wire - 2.032 mm dia.(14SWG) bare copper wire 1 m
CHAPTER 17: LIGHTNING PROTECTION
LG0001
Coefficient for per each of LG0001
Code Description Quant Units LB0051 Mason Gd.2 0.167 day LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.333 day MT5630 Copper tube finial with base plate 85x3mm - 25mm dia, 300mm long with sing 1 each
LG0002
Coefficient for per each of LG0002
Code Description Quant Units LB0051 Mason Gd.2 0.2 day LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.5 day MT5631 Copper tube finial with base plate 85x3mm - 25mm dia, 900mm long with fou 1 each
LG0003
Coefficient for per each of LG0003
Code Description Quant Units LB0051 Mason Gd.2 0.167 day LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.333 day MT5630 G.I tube finial with copper base plate 85x6mm - 25mm dia, 300mm long with s 1 each LG0015 Coefficient for per each of LG0015
Code Description Quant Units LB0054 Plumber Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day LG0016 Coefficient for per each of LG0016
Code Description Quant Units LB0054 Plumber Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day
LG0030
Coefficient for per each of LG0030
Code Description Quant Units LB0051 Mason Gd.2 0.0125 day
Rivetting, sweating and soldering as required - Copper tape with another copper tape
Rivetting, sweating and soldering as required - G.I tape with another G.I tape
Providing and fixing metal strip on parapet or surface of wall/roof for lightning conductor as required for horizontal run - 25x4mm G.I strip
Providing and drawing wire for loop earthing in existing surface/ recessed PVC/MS/ steel conduit or casing capping or wooden batten along with other wires as required - 2.032mm (14SWG) copper wire
Providing and fixing lightning conductor including holes etc. complete as required - 25mm dia 300mm long copper tube single prong at top with 85mm dia 3mm thick copper base plate
Providing and fixing lightning conductor including holes etc. complete as required - 25mm dia 900mm long copper tube four prong at top with 85mm dia 3mm thick copper base plate
Providing and fixing lightning conductor including holes etc. complete as required - 25mm dia 300mm long G.I tube single prong at top with 85mm dia 6mm thick copper base plate
Labour and Material Coefficients (Electrical)- 2013 Page 235
Department of Engineering Services, MoWHS
LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.0375 day MT6517 Strip - GI Tape\Strip 25x4 mm 1 m
LG0031
Coefficient for per each of LG0031
Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.0375 day MT6519 Strip - Copper Tape\Strip 25x4 1 m
LG0045
Coefficient for per each of LG0045
Code Description Quant Units LB0051 Mason Gd.2 0.025 day LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.075 day MT6517 Strip - GI Tape\Strip 25x4 mm 1 m
LG0046
Coefficient for per each of LG0046
Code Description Quant Units LB0051 Mason Gd.2 0.025 day LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.075 day MT6519 Strip - Copper Tape\Strip 25x4 1 m
CHAPTER 18: POWER CABLE (Supply)
PC0001
Coefficient for per m of PC0001
Code Description Quant Units
MT4210Power Cables (1.1kV) Single Core Aluminium-Unarmoured, PVC insulated & sheathed - 150 sq.mm 1 m
PC0002
Coefficient for per m of PC0002
Code Description Quant Units
MT4211Power Cables (1.1kV) Single Core Aluminium-Unarmoured, PVC insulated & sheathed - 185 sq.mm 1 m
PC0003
Coefficient for per m of PC0003
Code Description Quant Units
MT4212Power Cables (1.1kV) Single Core Aluminium-Unarmoured, PVC insulated & sheathed - 240 sq.mm 1 m
PC0004
Coefficient for per m of PC0004
Code Description Quant Units
MT4213Power Cables (1.1kV) Single Core Aluminium-Unarmoured, PVC insulated & sheathed - 300 sq.mm 1 m
Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 240 sq.mm
Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 300 sq.mm
Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 150 sq.mm
Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 185 sq.mm
Providing and fixing metal strip on parapet or surface of wall/roof for lightning conductor as required for horizontal run - 25x4mm copper strip
Providing and fixing metal strip on parapet or surface of wall/roof for lightning conductor as required for vertical run - 25x4mm G.I strip
Providing and fixing metal strip on parapet or surface of wall/roof for lightning conductor as required for vertical run - 25x4mm copper strip
Labour and Material Coefficients (Electrical)- 2013 Page 236
Department of Engineering Services, MoWHS
PC0005
Coefficient for per m of PC0005
Code Description Quant Units
MT4214Power Cables (1.1kV) Single Core Aluminium-Unarmoured, PVC insulated & sheathed - 400 sq.mm 1 m
PC0006
Coefficient for per m of PC0006
Code Description Quant Units
MT4215Power Cables (1.1kV) Single Core Aluminium-Unarmoured, PVC insulated & sheathed - 500 sq.mm 1 m
PC0020
Coefficient for per m of PC0020
Code Description Quant Units
MT4230Power Cables (1.1kV) 2- Core Aluminium-Unarmoured, PVC insulated & sheathed - 2.5 sq.mm 1 m
PC0021
Coefficient for per m of PC0021
Code Description Quant Units
MT4231Power Cables (1.1kV) 2- Core Aluminium-Unarmoured, PVC insulated & sheathed - 4 sq.mm 1 m
PC0022
Coefficient for per m of PC0022
Code Description Quant Units
MT4232Power Cables (1.1kV) 2- Core Aluminium-Unarmoured, PVC insulated & sheathed - 6 sq.mm 1 m
PC0023
Coefficient for per m of PC0023
Code Description Quant Units
MT4233Power Cables (1.1kV) 2- Core Aluminium-Unarmoured, PVC insulated & sheathed - 10 sq.mm 1 m
PC0024
Coefficient for per m of PC0024
Code Description Quant Units
MT4234Power Cables (1.1kV) 2- Core Aluminium-Unarmoured, PVC insulated & sheathed - 16 sq.mm 1 m
PC0035
Coefficient for per m of PC0035
Code Description Quant Units
MT4245Power Cables (1.1kV) 3- Core Aluminium-Unarmoured, PVC insulated & sheathed - 2.5 sq.mm 1 m
PC0036
Coefficient for per m of PC0036
Code Description Quant Units
MT4246Power Cables (1.1kV) 3- Core Aluminium-Unarmoured, PVC insulated & sheathed - 4 sq.mm 1 m
PC0037
Coefficient for per m of PC0037
Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 400 sq.mm
Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 500 sq.mm
Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 16 sq.mm
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured cables - 2.5 sq.mm
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 4 sq.mm
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 6 sq.mm
Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 2.5 sq.mm
Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 4 sq.mm
Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 6 sq.mm
Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 10 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 237
Department of Engineering Services, MoWHS
Code Description Quant Units
MT4247Power Cables (1.1kV) 3- Core Aluminium-Unarmoured, PVC insulated & sheathed - 6 sq.mm 1 m
PC0038
Coefficient for per m of PC0038
Code Description Quant Units
MT4248Power Cables (1.1kV) 3- Core Aluminium-Unarmoured, PVC insulated & sheathed - 10 sq.mm 1 m
PC0039
Coefficient for per m of PC0039
Code Description Quant Units
MT4249Power Cables (1.1kV) 3- Core Aluminium-Unarmoured, PVC insulated & sheathed - 16 sq.mm 1 m
PC0040
Coefficient for per m of PC0040
Code Description Quant Units
MT4250Power Cables (1.1kV) 3- Core Aluminium-Unarmoured, PVC insulated & sheathed - 25 sq.mm 1 m
PC0050
Coefficient for per m of PC0050
Code Description Quant Units
MT4260Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 25 sq.mm 1 m
PC0051
Coefficient for per m of PC0051
Code Description Quant Units
MT4261Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 35 sq.mm 1 m
PC0052
Coefficient for per m of PC0052
Code Description Quant Units
MT4262Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 50 sq.mm 1 m
PC0053
Coefficient for per m of PC0053
Code Description Quant Units
MT4263Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 70 sq.mm 1 m
PC0054
Coefficient for per m of PC0054
Code Description Quant Units
MT4264Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 95 sq.mm 1 m
PC0055
Coefficient for per m of PC0055
Code Description Quant Units
MT4265Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 120 sq.mm 1 m
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 35 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 50 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 70 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 95 sq.mm
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 10 sq.mm
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 16 sq.mm
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 25 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 25 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 120 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 238
Department of Engineering Services, MoWHS
PC0056
Coefficient for per m of PC0056
Code Description Quant Units
MT4266Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 150 sq.mm 1 m
PC0057
Coefficient for per m of PC0057
Code Description Quant Units
MT4268Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 225 sq.mm 1 m
PC0058
Coefficient for per m of PC0058
Code Description Quant Units
MT4269Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 240 sq.mm 1 m
PC0059
Coefficient for per m of PC0059
Code Description Quant Units
MT4270Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 300 sq.mm 1 m
PC0060
Coefficient for per m of PC0060
Code Description Quant Units
MT4271Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 400 sq.mm 1 m
PC0061
Coefficient for per m of PC0061
Code Description Quant Units
MT4272Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 500 sq.mm 1 m
PC0062
Coefficient for per m of PC0062
Code Description Quant Units
MT4273Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 630 sq.mm 1 m
PC0075
Coefficient for per m of PC0075
Code Description Quant Units
MT4285Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 2.5 sq.mm 1 m
PC0076
Coefficient for per m of PC0076
Code Description Quant Units
MT4286Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 4 sq.mm 1 m
PC0077
Coefficient for per m of PC0077
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 300 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 400 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 500 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 630 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 150 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 225 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 240 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 2.5 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 4 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 6 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 239
Department of Engineering Services, MoWHS
Code Description Quant Units
MT4287Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 6 sq.mm 1 m
PC0078
Coefficient for per m of PC0078
Code Description Quant Units
MT4288Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 10 sq.mm 1 m
PC0079
Coefficient for per m of PC0079
Code Description Quant Units
MT4289Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 16 sq.mm 1 m
PC0080
Coefficient for per m of PC0080
Code Description Quant Units
MT4290Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 25 sq.mm 1 m
PC0081
Coefficient for per m of PC0081
Code Description Quant Units
MT4291Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 35 sq.mm 1 m
PC0082
Coefficient for per m of PC0082
Code Description Quant Units
MT4292Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 50 sq.mm 1 m
PC0083
Coefficient for per m of PC0083
Code Description Quant Units
MT4293Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 70 sq.mm 1 m
PC0084
Coefficient for per m of PC0084
Code Description Quant Units
MT4294Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 95 sq.mm 1 m
PC0085
Coefficient for per m of PC0085
Code Description Quant Units
MT4295Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 120 sq.mm 1 m
PC0086
Coefficient for per m of PC0086
Code Description Quant Units
MT4296Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 150 sq.mm 1 m
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 10 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 16 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 25 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 35 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 50 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 70 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 95 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 120 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 150 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 240
Department of Engineering Services, MoWHS
PC0087
Coefficient for per m of PC0087
Code Description Quant Units
MT4297Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 225 sq.mm 1 m
PC0088
Coefficient for per m of PC0088
Code Description Quant Units
MT4298Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 240 sq.mm 1 m
PC0089
Coefficient for per m of PC0089
Code Description Quant Units
MT4299Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 300 sq.mm 1 m
PC0090
Coefficient for per m of PC0090
Code Description Quant Units
MT4300Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 400 sq.mm 1 m
PC0091
Coefficient for per m of PC0091
Code Description Quant Units
MT4301Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 500 sq.mm 1 m
PC0092
Coefficient for per m of PC0092
Code Description Quant Units
MT4302Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 630 sq.mm 1 m
PC0105
Coefficient for per m of PC0105
Code Description Quant Units
MT4110Power Cables (1.1kV) Single Core Aluminium-Armoured, PVC insulated & sheathed - 150 sq.mm 1 m
PC0106
Coefficient for per m of PC0106
Code Description Quant Units
MT4111Power Cables (1.1kV) Single Core Aluminium-Armoured, PVC insulated & sheathed - 185 sq.mm 1 m
PC0107
Coefficient for per m of PC0107
Code Description Quant Units
MT4112Power Cables (1.1kV) Single Core Aluminium-Armoured, PVC insulated & sheathed - 240 sq.mm 1 m
PC0108
Coefficient for per m of PC0108
Code Description Quant Units
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 240 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 300 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 400 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 500 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 225 sq.mm
Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 300 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 630 sq.mm
Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 150 sq.mm
Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 185 sq.mm
Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 240 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 241
Department of Engineering Services, MoWHS
MT4113Power Cables (1.1kV) Single Core Aluminium-Armoured, PVC insulated & sheathed - 300 sq.mm 1 m
PC0109
Coefficient for per m of PC0109
Code Description Quant Units
MT4114Power Cables (1.1kV) Single Core Aluminium-Armoured, PVC insulated & sheathed - 400 sq.mm 1 m
PC0110
Coefficient for per m of PC0110
Code Description Quant Units
MT4115Power Cables (1.1kV) Single Core Aluminium-Armoured, PVC insulated & sheathed - 500 sq.mm 1 m
PC0120
Coefficient for per m of PC0120
Code Description Quant Units
MT4125Power Cables (1.1kV) 2- Core Aluminium-Armoured, PVC insulated & sheathed - 2.5 sq.mm 1 m
PC0121
Coefficient for per m of PC0121
Code Description Quant Units
MT4126Power Cables (1.1kV) 2- Core Aluminium-Armoured, PVC insulated & sheathed - 4 sq.mm 1 m
PC0122
Coefficient for per m of PC0122
Code Description Quant Units
MT4127Power Cables (1.1kV) 2- Core Aluminium-Armoured, PVC insulated & sheathed - 6 sq.mm 1 m
PC0123
Coefficient for per m of PC0123
Code Description Quant Units
MT4128Power Cables (1.1kV) 2- Core Aluminium-Armoured, PVC insulated & sheathed - 10 sq.mm 1 m
PC0124
Coefficient for per m of PC0124
Code Description Quant Units
MT4129Power Cables (1.1kV) 2- Core Aluminium-Armoured, PVC insulated & sheathed - 16 sq.mm 1 m
PC0135
Coefficient for per m of PC0135
Code Description Quant Units
MT4140Power Cables (1.1kV) 3- Core Aluminium-Armoured, PVC insulated & sheathed - 2.5 sq.mm 1 m
PC0136
Coefficient for per m of PC0136
Code Description Quant Units
MT4141Power Cables (1.1kV) 3- Core Aluminium-Armoured, PVC insulated & sheathed - 4 sq.mm 1 m
PC0137
Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 400 sq.mm
Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 500 sq.mm
Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 2.5 sq.mm
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 2.5 sq.mm
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 4 sq.mm
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 6 sq.mm
Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 4 sq.mm
Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 6 sq.mm
Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 10 sq.mm
Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 16 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 242
Department of Engineering Services, MoWHS
Coefficient for per m of PC0137
Code Description Quant Units
MT4142Power Cables (1.1kV) 3- Core Aluminium-Armoured, PVC insulated & sheathed - 6 sq.mm 1 m
PC0138
Coefficient for per m of PC0138
Code Description Quant Units
MT4143Power Cables (1.1kV) 3- Core Aluminium-Armoured, PVC insulated & sheathed - 10 sq.mm 1 m
PC0139
Coefficient for per m of PC0139
Code Description Quant Units
MT4144Power Cables (1.1kV) 3- Core Aluminium-Armoured, PVC insulated & sheathed - 16 sq.mm 1 m
PC0140
Coefficient for per m of PC0140
Code Description Quant Units
MT4145Power Cables (1.1kV) 3- Core Aluminium-Armoured, PVC insulated & sheathed - 25 sq.mm 1 m
PC0150
Coefficient for per m of PC0150
Code Description Quant Units
MT4155Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 25 sq.mm 1 m
PC0151
Coefficient for per m of PC0151
Code Description Quant Units
MT4156Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 35 sq.mm 1 m
PC0152
Coefficient for per m of PC0152
Code Description Quant Units
MT4157Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 50 sq.mm 1 m
PC0153
Coefficient for per m of PC0153
Code Description Quant Units
MT4158Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 70 sq.mm 1 m
PC0154
Coefficient for per m of PC0154
Code Description Quant Units
MT4159Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 95 sq.mm 1 m
PC0155
Coefficient for per m of PC0155
Code Description Quant Units
MT4160Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 120 sq.mm 1 m
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 10 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 50 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 70 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 95 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 120 sq.mm
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 16 sq.mm
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 25 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 25 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 35 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 243
Department of Engineering Services, MoWHS
PC0156
Coefficient for per m of PC0156
Code Description Quant Units
MT4161Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 150 sq.mm 1 m
PC0157
Coefficient for per m of PC0157
Code Description Quant Units
MT4163Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 225 sq.mm 1 m
PC0158
Coefficient for per m of PC0158
Code Description Quant Units
MT4164Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 240 sq.mm 1 m
PC0159
Coefficient for per m of PC0159
Code Description Quant Units
MT4165Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 300 sq.mm 1 m
PC0160
Coefficient for per m of PC0160
Code Description Quant Units
MT4166Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 400 sq.mm 1 m
PC0161
Coefficient for per m of PC0161
Code Description Quant Units
MT4167Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 500 sq.mm 1 m
PC0162
Coefficient for per m of PC0162
Code Description Quant Units
MT4168Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 630 sq.mm 1 m
PC0175
Coefficient for per m of PC0175
Code Description Quant Units
MT4180Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 2.5 sq.mm 1 m
PC0176
Coefficient for per m of PC0176
Code Description Quant Units
MT4181Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 4 sq.mm 1 m
PC0177
Coefficient for per m of PC0177
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 6 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 4 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 400 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 500 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 630 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 2.5 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 150 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 225 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 240 sq.mm
Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 300 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 244
Department of Engineering Services, MoWHS
Code Description Quant Units
MT4182Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 6 sq.mm 1 m
PC0178
Coefficient for per m of PC0178
Code Description Quant Units
MT4183Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 10 sq.mm 1 m
PC0179
Coefficient for per m of PC0179
Code Description Quant Units
MT4184Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 16 sq.mm 1 m
PC0180
Coefficient for per m of PC0180
Code Description Quant Units
MT4185Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 25 sq.mm 1 m
PC0181
Coefficient for per m of PC0181
Code Description Quant Units
MT4186Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 35 sq.mm 1 m
PC0182
Coefficient for per m of PC0182
Code Description Quant Units
MT4187Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 50 sq.mm 1 m
PC0183
Coefficient for per m of PC0183
Code Description Quant Units
MT4188Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 70 sq.mm 1 m
PC0184
Coefficient for per m of PC0184
Code Description Quant Units
MT4189Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 95 sq.mm 1 m
PC0185
Coefficient for per m of PC0185
Code Description Quant Units
MT4190Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 120 sq.mm 1 m
PC0186
Coefficient for per m of PC0186
Code Description Quant Units
MT4191Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 150 sq.mm 1 m
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 10 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 70 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 95 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power 120 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 150 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 16 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 25 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 35 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 50 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 245
Department of Engineering Services, MoWHS
PC0187
Coefficient for per m of PC0187
Code Description Quant Units
MT4192Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 225 sq.mm 1 m
PC0188
Coefficient for per m of PC0188
Code Description Quant Units
MT4193Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 240 sq.mm 1 m
PC0189
Coefficient for per m of PC0189
Code Description Quant Units
MT4194Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 300 sq.mm 1 m
PC0190
Coefficient for per m of PC0190
Code Description Quant Units
MT4195Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 400 sq.mm 1 m
PC0191
Coefficient for per m of PC0191
Code Description Quant Units
MT4196Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 500 sq.mm 1 m
PC0192
Coefficient for per m of PC0192
Code Description Quant Units
MT4197Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 630 sq.mm 1 m
PC0205
Coefficient for per m of PC0205
Code Description Quant Units
MT4315Power Cables (1.1kV) 2- Core Copper- Armoured, PVC insulated & sheathed - 2.5 sq.mm 1 m
PC0206
Coefficient for per m of PC0206
Code Description Quant Units
MT4316Power Cables (1.1kV) 2- Core Copper-Armoured, PVC insulated & sheathed - 4 sq.mm 1 m
PC0207
Coefficient for per m of PC0207
Code Description Quant Units
MT4317Power Cables (1.1kV) 2- Core Copper-Armoured, PVC insulated & sheathed - 6 sq.mm 1 m
PC0208
Coefficient for per m of PC0208
Code Description Quant Units
Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 6 sq.mm
Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 10 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 600 sq.mm
Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 2.5 sq.mm
Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 4 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 225 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 240 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 300 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 400 sq.mm
Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 500 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 246
Department of Engineering Services, MoWHS
MT4318Power Cables (1.1kV) 2- Core Copper-Armoured, PVC insulated & sheathed - 10 sq.mm 1 m
PC0209
Coefficient for per m of PC0209
Code Description Quant Units
MT4319Power Cables (1.1kV) 2 - Core Copper-Armoured, PVC insulated & sheathed - 16 sq.mm 1 m
PC0220
Coefficient for per m of PC0220
Code Description Quant Units
MT4330Power Cables (1.1kV) 3- Core Copper-Armoured, PVC insulated & sheathed - 2.5 sq.mm 1 m
PC0221
Coefficient for per m of PC0221
Code Description Quant Units
MT4331Power Cables (1.1kV) 3- Core Copper-Armoured, PVC insulated & sheathed - 4 sq.mm 1 m
PC0222
Coefficient for per m of PC0222
Code Description Quant Units
MT4332Power Cables (1.1kV) 3- Core Copper-Armoured, PVC insulated & sheathed - 6 sq.mm 1 m
PC0223
Coefficient for per m of PC0223
Code Description Quant Units
MT4333Power Cables (1.1kV) 3- Core Copper-Armoured, PVC insulated & sheathed - 10 sq.mm 1 m
PC0224
Coefficient for per m of PC0224
Code Description Quant Units
MT4334Power Cables (1.1kV) 3- Core Copper-Armoured, PVC insulated & sheathed - 16 sq.mm 1 m
PC0225
Coefficient for per m of PC0225
Code Description Quant Units
MT4335Power Cables (1.1kV) 3- Core Copper-Armoured, PVC insulated & sheathed - 25 sq.mm
PC0235
Coefficient for per each of PC0235
Code Description Quant Units MT4725 Single Compression Gland, heavy duty brass - 20mm dia 1 each
PC0236
Coefficient for per each of PC0236
Code Description Quant Units MT4726 Single Compression Gland, heavy duty brass - 22mm dia 1 each
PC0237
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 25 sq.mm
Supplying of heavy duty brass single compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 20mm dia, 4sq.mm
Supplying of heavy duty brass single compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 22mm dia, 6sq.mm
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 6 sq.mm
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 10 sq.mm
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 16 sq.mm
Supplying of heavy duty brass single compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 25mm dia, 10sq.mm
Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 16 sq.mm
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 2.5 sq.mm
Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 4 sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 247
Department of Engineering Services, MoWHS
Coefficient for per each of PC0237
Code Description Quant Units MT4727 Single Compression Gland, heavy duty brass - 25mm dia 1 each
PC0238
Coefficient for per each of PC0238
Code Description Quant Units MT4728 Single Compression Gland, heavy duty brass - 27mm dia 1 each
PC0239
Coefficient for per each of PC0239
Code Description Quant Units MT4729 Single Compression Gland, heavy duty brass - 29mm dia 1 each
PC0250
Coefficient for per each of PC0250
Code Description Quant Units MT4730 Single Compression Gland, heavy duty brass - 33mm dia 1 each
PC0251
Coefficient for per each of PC0251
Code Description Quant Units MT4731 Single Compression Gland, heavy duty brass - 35mm dia 1 each
PC0252
Coefficient for per each of PC0252
Code Description Quant Units MT4732 Single Compression Gland, heavy duty brass - 38mm dia 1 each
PC0253
Coefficient for per each of PC0253
Code Description Quant Units MT4733 Single Compression Gland, heavy duty brass - 40mm dia 1 each
PC0254
Coefficient for per each of PC0254
Code Description Quant Units MT4734 Single Compression Gland, heavy duty brass - 45mm dia 1 each
PC0255
Coefficient for per each of PC0255
Code Description Quant Units MT4735 Single Compression Gland, heavy duty brass - 50mm dia 1 each
PC0256
Coefficient for per each of PC0256
Code Description Quant Units MT4736 Single Compression Gland, heavy duty brass - 55mm dia 1 each
Supplying of heavy duty brass single compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 27mm dia, 16sq.mm
Supplying of heavy duty brass single compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 29mm dia, 25sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 33mm dia, 35sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 35mm dia, 50sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 38mm dia, 70sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 40mm dia, 95sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 45mm dia, 120sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 50mm dia, 150sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 55mm dia, 185sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 248
Department of Engineering Services, MoWHS
PC0257
Coefficient for per each of PC0257
Code Description Quant Units MT4737 Single Compression Gland, heavy duty brass - 60mm dia 1 each
PC0258
Coefficient for per each of PC0258
Code Description Quant Units MT4738 Single Compression Gland, heavy duty brass - 63mm dia 1 each
PC0259
Coefficient for per each of PC0259
Code Description Quant Units MT4739 Single Compression Gland, heavy duty brass - 70mm dia 1 each
PC0260
Coefficient for per each of PC0260
Code Description Quant Units MT4740 Single Compression Gland, heavy duty brass - 78mm dia 1 each
PC0261
Coefficient for per each of PC0261
Code Description Quant Units MT4741 Single Compression Gland, heavy duty brass - 82mm dia 1 each
PC0262
Coefficient for per each of PC0262
Code Description Quant Units MT4742 Single Compression Gland, heavy duty brass - 85mm dia 1 each
PC0275
Coefficient for per each of PC0275
Code Description Quant Units MT4755 Double Compression Gland, heavy duty brass - 20mm dia 1 each
PC0276
Coefficient for per each of PC0276
Code Description Quant Units MT4756 Double Compression Gland, heavy duty brass - 22mm dia 1 each
PC0277
Coefficient for per each of PC0277
Code Description Quant Units MT4757 Double Compression Gland, heavy duty brass - 25mm dia 1 each
PC0278
Coefficient for per each of PC0278
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 60mm dia, 225sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 63mm dia, 240sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 70mm dia, 300sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 78mm dia, 400sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 82mm dia, 500sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 85mm dia, 630sq.mm
Supplying of heavy duty brass double compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 20mm dia, 4sq.mm
Supplying of heavy duty brass double compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 22mm dia, 6sq.mm
Supplying of heavy duty brass double compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 25mm dia, 10sq.mm
Supplying of heavy duty brass double compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 27mm dia, 16sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 249
Department of Engineering Services, MoWHS
Code Description Quant Units MT4758 Double Compression Gland, heavy duty brass - 27mm dia 1 each
PC0279
Coefficient for per each of PC0279
Code Description Quant Units MT4759 Double Compression Gland, heavy duty brass - 29mm dia 1 each
PC0290
Coefficient for per each of PC0290
Code Description Quant Units MT4760 Double Compression Gland, heavy duty brass - 33mm dia 1 each
PC0291
Coefficient for per each of PC0291
Code Description Quant Units MT4761 Double Compression Gland, heavy duty brass - 35mm dia 1 each
PC0292
Coefficient for per each of PC0292
Code Description Quant Units MT4762 Double Compression Gland, heavy duty brass - 38mm dia 1 each
PC0293
Coefficient for per each of PC0293
Code Description Quant Units MT4763 Double Compression Gland, heavy duty brass - 40mm dia 1 each
PC0294
Coefficient for per each of PC0294
Code Description Quant Units MT4764 Double Compression Gland, heavy duty brass - 45mm dia 1 each
PC0295
Coefficient for per each of PC0295
Code Description Quant Units MT4765 Double Compression Gland, heavy duty brass - 50mm dia 1 each
PC0296
Coefficient for per each of PC0296
Code Description Quant Units MT4766 Double Compression Gland, heavy duty brass - 55mm dia 1 each
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 45mm dia, 120sq.mm
Supplying of heavy duty brass double compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 29mm dia, 25sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 33mm dia, 35sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 35mm dia, 50sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 38mm dia, 70sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 40mm dia, 95sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 50mm dia, 150sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 55mm dia, 185sq.mm
Labour and Material Coefficients (Electrical)- 2013 Page 250
Department of Engineering Services, MoWHS
PC0297
Coefficient for per each of PC0297
Code Description Quant Units MT4767 Double Compression Gland, heavy duty brass - 60mm dia 1 each
PC0298
Coefficient for per each of PC0298
Code Description Quant Units MT4768 Double Compression Gland, heavy duty brass - 63mm dia 1 each
PC0299
Coefficient for per each of PC0299
Code Description Quant Units MT4769 Double Compression Gland, heavy duty brass - 70mm dia 1 each
PC0300
Coefficient for per each of PC0300
Code Description Quant Units MT4770 Double Compression Gland, heavy duty brass - 78mm dia 1 each
PC0301
Coefficient for per each of PC0301
Code Description Quant Units MT4771 Double Compression Gland, heavy duty brass - 82mm dia 1 each
PC0302
Coefficient for per each of PC0302
Code Description Quant Units MT4772 Double Compression Gland, heavy duty brass - 85mm dia 1 each
CHAPTER 19: POWER CABLE LAYING
Coefficient for per m of CL0001
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day LB0077 Labourer 0.68207 day MT6604 Sand 0.0876 cu.m MT6680 Bricks 2nd class 0.01 1000#
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 60mm dia, 225sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 63mm dia, 240sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 78mm dia, 400sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 82mm dia, 500sq.mm
Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 85mm dia, 630sq.mm
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core direct in the ground including excavation, sandcushing, protective covering and refilling the trenches etc. as required - Upto 6sq.mm
CL0001
Labour and Material Coefficients (Electrical)- 2013 Page 251
Department of Engineering Services, MoWHS
Coefficient for per m of CL0002
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day LB0077 Labourer 0.68207 day MT6604 Sand 0.0876 cu.m MT6680 Bricks 2nd class 0.01 1000#
Coefficient for per m of CL0003
Code Description Quant Units LB0056 Wireman Gd.1 0.036 day LB0069 Wireman Gd.2 0.036 day LB0077 Labourer 0.68207 day MT6604 Sand 0.0876 cu.m MT6680 Bricks 2nd class 0.01 1000#
Coefficient for per m of CL0004
Code Description Quant Units LB0056 Wireman Gd.1 0.042 day LB0069 Wireman Gd.2 0.042 day LB0077 Labourer 0.68207 day MT6604 Sand 0.0876 cu.m MT6680 Bricks 2nd class 0.01 1000#
Coefficient for per m of CL0005
Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day LB0077 Labourer 0.68207 day MT6604 Sand 0.0876 cu.m MT6680 Bricks 2nd class 0.01 1000#
Coefficient for per m of CL0006
Code Description Quant Units LB0056 Wireman Gd.1 0.06 day LB0069 Wireman Gd.2 0.06 day LB0077 Labourer 0.68207 day MT6604 Sand 0.0876 cu.m MT6680 Bricks 2nd class 0.01 1000#
cushing, protective covering and refilling the trenches etc. as required - Above 25sq.mm to 70sq.mm
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core direct in the ground including excavation, sand
cushing, protective covering and refilling the trenches etc. as required - Above 6sq.mm to 25sq.mm
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core direct in the ground including excavation, sand CL0002
CL0003
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core direct in the ground including excavation, sand cushing, protective covering and refilling the trenches etc. as required - Above 70sq.mm to 150sq.mm
CL0004
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core direct in the ground including excavation, sand cushing, protective covering and refilling the trenches etc. as required - Above 150sq.mm to 300sq.mm
CL0005
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core direct in the ground including excavation, sand cushing, protective covering and refilling the trenches etc. as required - Above 300sq.mm to 630sq.mm
CL0006
Labour and Material Coefficients (Electrical)- 2013 Page 252
Department of Engineering Services, MoWHS
Coefficient for per m of CL0020
Code Description Quant Units LB0056 Wireman Gd.1 0.015 day LB0069 Wireman Gd.2 0.015 day LB0077 Labourer 0.34103 day MT6604 Sand 0.046 cu.m MT6680 Bricks 2nd class 0.01 1000#
Coefficient for per m of CL0021
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day LB0077 Labourer 0.34103 day MT6604 Sand 0.046 cu.m MT6680 Bricks 2nd class 0.01 1000#
Coefficient for per m of CL0022
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day LB0077 Labourer 0.34103 day MT6604 Sand 0.046 cu.m MT6680 Bricks 2nd class 0.01 1000#
Coefficient for per m of CL0023
Code Description Quant Units LB0056 Wireman Gd.1 0.036 day LB0069 Wireman Gd.2 0.036 day LB0077 Labourer 0.34103 day MT6604 Sand 0.046 cu.m MT6680 Bricks 2nd class 0.01 1000#
Coefficient for per m of CL0024
Code Description Quant Units LB0056 Wireman Gd.1 0.044 day LB0069 Wireman Gd.2 0.044 day LB0077 Labourer 0.34103 day MT6604 Sand 0.046 cu.m MT6680 Bricks 2nd class 0.01 1000#
Coefficient for per m of CL0040
Code Description Quant Units LB0056 Wireman Gd.1 0.01 day LB0069 Wireman Gd.2 0.01 day
Extra for laying of one number additional PVC insulated and sheathed power cable copper/aluminium, armoured/un-armoured 1.1KV single core to four core direct in the ground in the same trench in one tier horizontal formation including excavation, sand cushing, protective covering and refilling trenches etc. as required - Upto 6sq.mm
CL0020
Extra for laying of one number additional PVC insulated and sheathed power cable copper/aluminium, armoured/un-armoured 1.1KV single core to four core direct in the ground in the same trench in one tier horizontal formation including excavation, sand cushing, protective covering and refilling the as required - Above 6sq.mm to 25sq.mm
CL0021
Extra for laying of one number additional PVC insulated and sheathed power cable copper/aluminium, armoured/un-armoured 1.1KV single core to four core direct in the ground in the same trench in one tier horizontal formation including excavation, sand cushing, protective covering and refilling the
CL0022
Extra for laying of one number additional PVC insulated and sheathed power cable copper/aluminium, armoured/un-armoured 1.1KV single core to four core direct in the ground in the same trench in one tier horizontal formation including excavation, sand cushing, protective covering and refilling the as required - Above 70sq.mm to 150sq.mm
CL0023
Extra for laying of one number additional PVC insulated and sheathed power cable copper/aluminium, armoured/un-armoured 1.1KV single core to four core direct in the ground in the same trench in one tier horizontal formation including excavation, sand cushing,protective covering and refilling the as required - Above 150sq.mm to 300sq.mm
CL0024
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting RCC/ Hume/ Stone ware/ G.I pipes as required - Upto 6sq.mm
CL0040
Labour and Material Coefficients (Electrical)- 2013 Page 253
Department of Engineering Services, MoWHS
Coefficient for per m of CL0041
Code Description Quant Units LB0056 Wireman Gd.1 0.013 day LB0069 Wireman Gd.2 0.013 day
Coefficient for per m of CL0042
Code Description Quant Units LB0056 Wireman Gd.1 0.017 day LB0069 Wireman Gd.2 0.017 day
Coefficient for per m of CL0043
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day
Coefficient for per m of CL0044
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day
Coefficient for per m of CL0045
Code Description Quant Units LB0056 Wireman Gd.1 0.035 day LB0069 Wireman Gd.2 0.035 day
Coefficient for per m of CL0055
Code Description Quant Units LB0056 Wireman Gd.1 0.01 day LB0069 Wireman Gd.2 0.01 day
Coefficient for per m of CL0056
Code Description Quant Units LB0056 Wireman Gd.1 0.013 day LB0069 Wireman Gd.2 0.013 day
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting RCC/ Hume/ Stone ware/ G.I pipes as required - Above 6sq.mm to 25sq.mm
CL0041
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting RCC/ Hume/ Stone ware/ G.I pipes as required - Above 25sq.mm to 70sq.mm
CL0042
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting RCC/ Hume/ Stone ware/ G.I pipes as required - Above 70sq.mm to 150sq.mm
CL0043
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting RCC/ Hume/ Stone ware/ G.I pipes as required - Above 150sq.mm to 300sq.mm
CL0044
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting RCC/ Hume/ Stone ware/ G.I pipes as required - Above 300sq.mm to 630sq.mm
CL0045
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting masonry open duct as required - Upto 6sq.mm
CL0055
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting masonry open duct as required - Above 6sq.mm to 25sq.mm
CL0056
Labour and Material Coefficients (Electrical)- 2013 Page 254
Department of Engineering Services, MoWHS
Coefficient for per m of CL0057
Code Description Quant Units LB0056 Wireman Gd.1 0.017 day LB0069 Wireman Gd.2 0.017 day
Coefficient for per m of CL0058
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day
Coefficient for per m of CL0059
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day
Coefficient for per m of CL0060
Code Description Quant Units LB0056 Wireman Gd.1 0.035 day LB0069 Wireman Gd.2 0.035 day
CL0070
Coefficient for per each of CL0070
Code Description Quant Units LB0036 Mason Gd.1 0.00187 day LB0039 Work Supervisor (Lajab) 0.0015 day LB0051 Mason Gd.2 0.00187 day LB0053 Plant Operator Gd.3 0.0021 day LB0056 Wireman Gd.1 0.167 day LB0069 Wireman Gd.2 0.167 day LB0077 Labourer 0.25188 day MP0001 Concrete Mixer 0.0021 day MP0002 Concrete Vibrator 0.0021 day MT6604 Sand 0.01335 cu.m MT6623 Stone Aggregates - 20mm 0.0267 cu.m MT6681 Grey Cement 0.00964 tonne
Coefficient for per each of CL0080
Code Description Quant Units LB0036 Mason Gd.1 0.00008 day LB0039 Work Supervisor (Lajab) 0.00007 day LB0051 Mason Gd.2 0.00008 day LB0053 Plant Operator Gd.3 0.00009 day LB0056 Wireman Gd.1 0.167 day
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting masonry open duct as required - Above 25sq.mm to 70sq.mm
CL0057
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting masonry open duct as required - Above 70sq.mm to 150sq.mm
CL0058
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting masonry open duct as required - Above 150sq.mm to 300sq.mm
CL0059
Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting masonry open duct as required - Above 300sq.mm to 630sq.mm
CL0060
Providing and making route marker of size 600x600mm at bottom and 500x500mm at top with a thickness of 100mm including inscreption as required - With cement concrete 1:2:4, 20mm stone aggregate
Providing and making route marker of size 150x100x6mm with necessary nuts & bolts 100mm long 10mm dia with washer embeded in cement concrete 1:2:4, 20mm stone aggregate including inscription as required - With cement concrete 1:2:4, 20mm stone aggregate
CL0080
Labour and Material Coefficients (Electrical)- 2013 Page 255
Department of Engineering Services, MoWHS
LB0069 Wireman Gd.2 0.167 day LB0077 Labourer 0.00404 day MT4785 C.I Route Marker, 150x100x6mm 1 each MP0001 Concrete Mixer 0.00009 day MP0002 Concrete Vibrator 0.00009 day MT6604 Sand 0.00058 cu.m MT6623 Stone Aggregates - 20mm 0.00116 cu.m MT6681 Grey Cement 0.00042 tonne
Coefficient for per each of CL0090
Code Description Quant Units LB0024 Lineman Gd.1 0.75 day LB0069 Wireman Gd.2 0.75 day MT4786 Straight through cable joint box 1 each
Coefficient for per each of CL0091
Code Description Quant Units LB0024 Lineman Gd.1 1 day LB0069 Wireman Gd.2 1 day MT4786 Straight through cable joint box 1 each
Coefficient for per each of CL0092
Code Description Quant Units LB0024 Lineman Gd.1 1.5 day LB0069 Wireman Gd.2 1.5 day MT4786 Straight through cable joint box 1 each
Coefficient for per each of CL0093
Code Description Quant Units LB0024 Lineman Gd.1 1.75 day LB0069 Wireman Gd.2 1.75 day MT4786 Straight through cable joint box 1 each
Coefficient for per each of CL0094
Code Description Quant Units LB0024 Lineman Gd.1 1.1 day LB0069 Wireman Gd.2 1.1 day MT4786 Straight through cable joint box 1 each
Coefficient for per each of CL0095
Code Description Quant Units LB0024 Lineman Gd.1 1.6 day LB0069 Wireman Gd.2 1.6 day MT4786 Straight through cable joint box 1 each
Providing and fixing straight through joint box including ferrules and other jointing materials for under- ground PVC sheathed cable 1.1KV including making joints and filling with bitumenous compound for the aluminium conductor cable - 4-Core, 50/70/95sq.mm
CL0095
Providing and fixing straight through joint box including ferrules and other jointing materials for under- ground PVC sheathed cable 1.1KV including making joints and filling with bitumenous compound for the aluminium conductor cable - 2-Core, 6/10/16sq.mm
CL0090
Providing and fixing straight through joint box including ferrules and other jointing materials for under- ground PVC sheathed cable 1.1KV including making joints and filling with bitumenous compound for the aluminium conductor cable - 3.5-Core, 25/35/50sq.mm
CL0091
Providing and fixing straight through joint box including ferrules and other jointing materials for under- ground PVC sheathed cable 1.1KV including making joints and filling with bitumenous compound for the aluminium conductor cable - 3.5-Core, 70/95/120sq.mm
CL0092
Providing and fixing straight through joint box including ferrules and other jointing materials for under- ground PVC sheathed cable 1.1KV including making joints and filling with bitumenous compound for the aluminium conductor cable - 3.5-Core, 240/300sq.mm
CL0093
Providing and fixing straight through joint box including ferrules and other jointing materials for under- ground PVC sheathed cable 1.1KV including making joints and filling with bitumenous compound for the aluminium conductor cable - 4-Core, 16/25/35sq.mm
CL0094
Labour and Material Coefficients (Electrical)- 2013 Page 256
Department of Engineering Services, MoWHS
Coefficient for per each of CL0096
Code Description Quant Units LB0024 Lineman Gd.1 1.8 day LB0069 Wireman Gd.2 1.8 day MT4786 Straight through cable joint box 1 each
Coefficient for per each of CL0110
Code Description Quant Units LB0024 Lineman Gd.1 0.125 day LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4680 Ferrule type brass thimble - 32A 2 each MT4700 Ferrule type aluminium alloy thimble - 16A 2 each
Coefficient for per each of CL0111
Code Description Quant Units LB0024 Lineman Gd.1 0.167 day LB0056 Wireman Gd.1 0.167 day LB0069 Wireman Gd.2 0.167 day MT4682 Ferrule type brass thimble - 50A 2 each MT4683 Ferrule type brass thimble - 63A 2 each
Coefficient for per each of CL0112
Code Description Quant Units LB0024 Lineman Gd.1 0.25 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4705 Ferrule type aluminium alloy thimble - 100A 2 each MT4707 Ferrule type aluminium alloy thimble - 130A 2 each
Coefficient for per each of CL0113
Code Description Quant Units LB0024 Lineman Gd.1 0.33 day LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4708 Ferrule type aluminium alloy thimble - 150A 2 each MT4710 Ferrule type aluminium alloy thimble - 200A 2 each
Coefficient for per each of CL0114
Code Description Quant Units LB0024 Lineman Gd.1 0.5 day
Installation, Testing and Commissioning of end termination with single/double compresion gland for PVC insulated and sheathed aluminium/ copper conductor cable of 1.1KV grade including connections etc. as required - 60/63/70mm dia
CL0114
Installation, Testing and Commissioning of end termination with single/double compresion gland for PVC insulated and sheathed aluminium/ copper conductor cable of 1.1KV grade including connections etc. as required - 35/38/40mm dia
CL0112
Installation, Testing and Commissioning of end termination with single/double compresion gland for PVC insulated and sheathed aluminium/ copper conductor cable of 1.1KV grade including connections etc. as required - 45/50/55mm dia
CL0113
Installation, Testing and Commissioning of end termination with single/double compresion gland for PVC insulated and sheathed aluminium/ copper conductor cable of 1.1KV grade including connections etc. as required - 20/22/25mm dia
CL0110
Installation, Testing and Commissioning of end termination with single/double compresion gland for PVC insulated and sheathed aluminium/ copper conductor cable of 1.1KV grade including connections etc. as required - 27/29/33mm dia
CL0111
Providing and fixing straight through joint box including ferrules and other jointing materials for under- ground PVC sheathed cable 1.1KV including making joints and filling with bitumenous compound for the aluminium conductor cable - 4-Core, 120/150/300sq.mm
CL0096
Labour and Material Coefficients (Electrical)- 2013 Page 257
Department of Engineering Services, MoWHS
LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4710 Ferrule type aluminium alloy thimble - 200A 2 each MT4711 Ferrule type aluminium alloy thimble - 300A 2 each
Coefficient for per each of CL0115
Code Description Quant Units LB0024 Lineman Gd.1 1 day LB0056 Wireman Gd.1 1 day LB0069 Wireman Gd.2 1 day MT4712 Ferrule type aluminium alloy thimble - 330A 2 each MT4713 Ferrule type aluminium alloy thimble - 425A 2 each
CHAPTER 20: CONTROL CABLE
CC0001
Coefficient for per m of CC0001
Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0067 Painter Gd.2 0.009 day LB0077 Labourer 0.024 day
MT4445Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 2-Core 1.01 m
CC0002
Coefficient for per m of CC0002
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.009 day LB0077 Labourer 0.025 day
MT4446Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 3-Core 1.01 m
CC0003
Coefficient for per m of CC0003
Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0067 Painter Gd.2 0.01 day LB0077 Labourer 0.026 day
MT4447Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 4-Core 1.01 m
CC0004
Coefficient for per m of CC0004
Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0067 Painter Gd.2 0.01 day LB0077 Labourer 0.026 day
MT4448Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 5-Core 1.01 m
CC0005
Coefficient for per m of CC0005
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0067 Painter Gd.2 0.011 day LB0077 Labourer 0.028 day
MT4449Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 6-Core 1.01 m
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 2-Core
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 3-Core
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 4-Core
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 5-Core
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 6-Core
Installation, Testing and Commissioning of end termination with single/double compresion gland for PVC insulated and sheathed aluminium/ copper conductor cable of 1.1KV grade including connections etc. as required - 78/82/85mm dia
CL0115
Labour and Material Coefficients (Electrical)- 2013 Page 258
Department of Engineering Services, MoWHS
CC0006
Coefficient for per m of CC0006
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0067 Painter Gd.2 0.011 day LB0077 Labourer 0.028 day
MT4450Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 7-Core 1.01 m
CC0007
Coefficient for per m of CC0007
Code Description Quant Units LB0056 Wireman Gd.1 0.031 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.031 day
MT4451Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 10-Core 1.01 m
CC0008
Coefficient for per m of CC0008
Code Description Quant Units LB0056 Wireman Gd.1 0.029 day LB0067 Painter Gd.2 0.011 day LB0077 Labourer 0.029 day
MT4452Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 12-Core 1.01 m
CC0009
Coefficient for per m of CC0009
Code Description Quant Units LB0056 Wireman Gd.1 0.031 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.031 day
MT4453Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 14-Core 1.01 m
CC0010
Coefficient for per m of CC0010
Code Description Quant Units LB0056 Wireman Gd.1 0.032 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.032 day
MT4454Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 16-Core 1.01 m
CC0011
Coefficient for per m of CC0011
Code Description Quant Units LB0056 Wireman Gd.1 0.033 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.033 day
MT4455Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 19-Core 1.01 m
CC0012
Coefficient for per m of CC0012
Code Description Quant Units LB0056 Wireman Gd.1 0.034 day
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 16-Core
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 19-Core
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 24-Core
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 7-Core
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 10-Core
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) -12-Core
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 14-Core
Labour and Material Coefficients (Electrical)- 2013 Page 259
Department of Engineering Services, MoWHS
LB0067 Painter Gd.2 0.013 day LB0077 Labourer 0.034 day
MT4456Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 24-Core 1.01 m
CC0013
Coefficient for per m of CC0013
Code Description Quant Units LB0056 Wireman Gd.1 0.036 day LB0067 Painter Gd.2 0.014 day LB0077 Labourer 0.036 day
MT4457Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 27-Core 1.01 m
CC0014
Coefficient for per m of CC0014
Code Description Quant Units LB0056 Wireman Gd.1 0.036 day LB0067 Painter Gd.2 0.014 day LB0077 Labourer 0.036 day
MT4458Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 30-Core 1.01 m
CC0015
Coefficient for per m of CC0015
Code Description Quant Units LB0056 Wireman Gd.1 0.038 day LB0067 Painter Gd.2 0.014 day LB0077 Labourer 0.038 day
MT4459Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 37-Core 1.01 m
CC0016
Coefficient for per m of CC0016
Code Description Quant Units LB0056 Wireman Gd.1 0.04 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.04 day
MT4460Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 44-Core 1.01 m
CC0017
Coefficient for per m of CC0017
Code Description Quant Units LB0056 Wireman Gd.1 0.041 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.041 day
MT4461Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 52-Core 1.01 m
CC0018
Coefficient for per m of CC0018
Code Description Quant Units LB0056 Wireman Gd.1 0.043 day LB0067 Painter Gd.2 0.016 day LB0077 Labourer 0.043 day
MT4462Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 61-Core 1.01 m
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 52-Core
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 61-Core
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 27-Core
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 30-Core
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 37-Core
Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) -44-Core
Labour and Material Coefficients (Electrical)- 2013 Page 260
Department of Engineering Services, MoWHS
CC0030
Coefficient for per m of CC0030
Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0067 Painter Gd.2 0.01 day LB0077 Labourer 0.026 day
MT4475Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 2-Core 1.01 m
CC0031
Coefficient for per m of CC0031
Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0067 Painter Gd.2 0.01 day LB0077 Labourer 0.026 day
MT4476Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 3-Core 1.01 m
CC0032
Coefficient for per m of CC0032
Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0067 Painter Gd.2 0.011 day LB0077 Labourer 0.028 day
MT4477Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 4-Core 1.01 m
CC0033
Coefficient for per m of CC0033
Code Description Quant Units LB0056 Wireman Gd.1 0.029 day LB0067 Painter Gd.2 0.011 day LB0077 Labourer 0.029 day
MT4478Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 5-Core 1.01 m
CC0034
Coefficient for per m of CC0034
Code Description Quant Units LB0056 Wireman Gd.1 0.031 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.031 day
MT4479Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 6-Core 1.01 m
CC0035
Coefficient for per m of CC0035
Code Description Quant Units LB0056 Wireman Gd.1 0.031 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.031 day
MT4480Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 7-Core 1.01 m
CC0036
Coefficient for per m of CC0036
Code Description Quant Units LB0056 Wireman Gd.1 0.032 day
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 6-Core
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 7-Core
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 10-Core
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 2-Core
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 3-Core
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 4-Core
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 5-Core
Labour and Material Coefficients (Electrical)- 2013 Page 261
Department of Engineering Services, MoWHS
LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.032 day
MT4481Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 10-Core 1.01 m
CC0037
Coefficient for per m of CC0037
Code Description Quant Units LB0056 Wireman Gd.1 0.033 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.033 day
MT4482Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 12-Core 1.01 m
CC0038
Coefficient for per m of CC0038
Code Description Quant Units LB0056 Wireman Gd.1 0.033 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.033 day
MT4483Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 14-Core 1.01 m
CC0039
Coefficient for per m of CC0039
Code Description Quant Units LB0056 Wireman Gd.1 0.035 day LB0067 Painter Gd.2 0.013 day LB0077 Labourer 0.035 day
MT4484Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 16-Core 1.01 m
CC0040
Coefficient for per m of CC0040
Code Description Quant Units LB0056 Wireman Gd.1 0.035 day LB0067 Painter Gd.2 0.013 day LB0077 Labourer 0.035 day
MT4485Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 19-Core 1.01 m
CC0041
Coefficient for per m of CC0041
Code Description Quant Units LB0056 Wireman Gd.1 0.038 day LB0067 Painter Gd.2 0.014 day LB0077 Labourer 0.038 day
MT4486Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 24-Core 1.01 m
CC0042
Coefficient for per m of CC0042
Code Description Quant Units LB0056 Wireman Gd.1 0.039 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.039 day
MT4487Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 27-Core 1.01 m
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 12-Core
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 14-Core
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 16-Core
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 19-Core
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 24-Core
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 27-Core
Labour and Material Coefficients (Electrical)- 2013 Page 262
Department of Engineering Services, MoWHS
CC043
Coefficient for per m of CC0043
Code Description Quant Units LB0056 Wireman Gd.1 0.04 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.04 day
MT4488Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 30-Core 1.01 m
CC0044
Coefficient for per m of CC0044
Code Description Quant Units LB0056 Wireman Gd.1 0.041 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.041 day
MT4489Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 37-Core 1.01 m
CC0045
Coefficient for per m of CC0045
Code Description Quant Units LB0056 Wireman Gd.1 0.044 day LB0067 Painter Gd.2 0.017 day LB0077 Labourer 0.044 day
MT4490Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 44-Core 1.01 m
CC0046
Coefficient for per m of CC0046
Code Description Quant Units LB0056 Wireman Gd.1 0.044 day LB0067 Painter Gd.2 0.017 day LB0077 Labourer 0.044 day
MT4491Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 52-Core 1.01 m
CC0047
Coefficient for per m of CC0047
Code Description Quant Units LB0056 Wireman Gd.1 0.045 day LB0067 Painter Gd.2 0.017 day LB0077 Labourer 0.045 day
MT4492Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 61-Core 1.01 m
CC0060
Coefficient for per m of CC0060
Code Description Quant Units LB0056 Wireman Gd.1 0.017 day LB0067 Painter Gd.2 0.006 day LB0077 Labourer 0.017 day
MT4505Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 2-Core 1.01 m
CC0061
Coefficient for per m of CC0061
Code Description Quant Units LB0056 Wireman Gd.1 0.019 day
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 3-Core
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 30-Core
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 37-Core
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 44-Core
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 52-Core
Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 61-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 2-Core
Labour and Material Coefficients (Electrical)- 2013 Page 263
Department of Engineering Services, MoWHS
LB0067 Painter Gd.2 0.007 day LB0077 Labourer 0.019 day
MT4506Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 3-Core 1.01 m
CC0062
Coefficient for per m of CC0062
Code Description Quant Units LB0056 Wireman Gd.1 0.019 day LB0067 Painter Gd.2 0.007 day LB0077 Labourer 0.019 day
MT4507Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 4-Core 1.01 m
CC0063
Coefficient for per m of CC0063
Code Description Quant Units LB0056 Wireman Gd.1 0.021 day LB0067 Painter Gd.2 0.008 day LB0077 Labourer 0.021 day
MT4508Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 5-Core 1.01 m
CC0064
Coefficient for per m of CC0064
Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0067 Painter Gd.2 0.009 day LB0077 Labourer 0.023 day
MT4509Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 6-Core 1.01 m
CC0065
Coefficient for per m of CC0065
Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0067 Painter Gd.2 0.009 day LB0077 Labourer 0.023 day
MT4510Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 7-Core 1.01 m
CC0066
Coefficient for per m of CC0066
Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0067 Painter Gd.2 0.01 day LB0077 Labourer 0.026 day
MT4511Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 10-Core 1.01 m
CC0067
Coefficient for per m of CC0067
Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0067 Painter Gd.2 0.01 day LB0077 Labourer 0.027 day
MT4512Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 12-Core 1.01 m
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 12-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 4-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 5-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 6-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 7-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 10-Core
Labour and Material Coefficients (Electrical)- 2013 Page 264
Department of Engineering Services, MoWHS
CC0068
Coefficient for per m of CC0068
Code Description Quant Units LB0056 Wireman Gd.1 0.029 day LB0067 Painter Gd.2 0.011 day LB0077 Labourer 0.029 day
MT4513Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 14-Core 1.01 m
CC0069
Coefficient for per m of CC0069
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.011 day LB0077 Labourer 0.03 day
MT4514Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 16-Core 1.01 m
CC0070
Coefficient for per m of CC0070
Code Description Quant Units LB0056 Wireman Gd.1 0.031 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.031 day
MT4515Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 19-Core 1.01 m
CC0071
Coefficient for per m of CC0071
Code Description Quant Units LB0056 Wireman Gd.1 0.034 day LB0067 Painter Gd.2 0.013 day LB0077 Labourer 0.034 day
MT4516Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 24-Core 1.01 m
CC0072
Coefficient for per m of CC0072
Code Description Quant Units LB0056 Wireman Gd.1 0.034 day LB0067 Painter Gd.2 0.013 day LB0077 Labourer 0.034 day
MT4517Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 27-Core 1.01 m
CC0073
Coefficient for per m of CC0073
Code Description Quant Units LB0056 Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & she 0.035 day LB0067 Painter Gd.2 0.013 day LB0077 Labourer 0.035 day
MT4518Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 30-Core 1.01 m
CC0074
Coefficient for per m of CC0074
Code Description Quant Units LB0056 Wireman Gd.1 0.036 day LB0067 Painter Gd.2 0.014 day
LB0077 Labourer 0.036 day
MT4519Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 37-Core 1.01 m
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 30-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 37-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 14-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 16-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 19-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 24-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 27-Core
Labour and Material Coefficients (Electrical)- 2013 Page 265
Department of Engineering Services, MoWHS
CC0075
Coefficient for per m of CC0075
Code Description Quant Units LB0056 Wireman Gd.1 0.039 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.039 day
MT4520Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 44-Core 1.01 m
CC0076
Coefficient for per m of CC0076
Code Description Quant Units LB0056 Wireman Gd.1 0.041 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.041 day
MT4521Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 52-Core 1.01 m
CC0077
Coefficient for per m of CC0077
Code Description Quant Units LB0056 Wireman Gd.1 0.041 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.041 day
MT4522Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 61-Core 1.01 m
CC0090
Coefficient for per m of CC0090
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0067 Painter Gd.2 0.008 day LB0077 Labourer 0.02 day
MT4535Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 2-Core 1.01 m
CC0091
Coefficient for per m of CC0091
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0067 Painter Gd.2 0.008 day LB0077 Labourer 0.02 day
MT4536Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 3-Core 1.01 m
CC0092
Coefficient for per m of CC0092
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.008 day LB0077 Labourer 0.022 day
MT4537Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 4-Core 1.01 m
CC0093
Coefficient for per m of CC0093
Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0067 Painter Gd.2 0.009 day LB0077 Labourer 0.023 day MT4538 Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & she 1.01 m
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 3-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 4-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 5-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 44-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 52-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 61-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 2-Core
Labour and Material Coefficients (Electrical)- 2013 Page 266
Department of Engineering Services, MoWHS
CC0094
Coefficient for per m of CC0094
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.009 day LB0077 Labourer 0.025 day
MT4539Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 6-Core 1.01 m
CC0095
Coefficient for per m of CC0095
Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.009 day LB0077 Labourer 0.025 day
MT4540Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 7-Core 1.01 m
CC0096
Coefficient for per m of CC0096
Code Description Quant Units LB0056 Wireman Gd.1 0.029 day LB0067 Painter Gd.2 0.011 day LB0077 Labourer 0.029 day
MT4541Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 10-Core 1.01 m
CC0097
Coefficient for per m of CC0097
Code Description Quant Units LB0056 Wireman Gd.1 0.031 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer (Male) 0.031 day
MT4542Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 12-Core 1.01 m
CC0098
Coefficient for per m of CC0098
Code Description Quant Units LB0056 Wireman Gd.1 0.032 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.032 day
MT4543Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 14-Core 1.01 m
CC0099
Coefficient for per m of CC0099
Code Description Quant Units LB0056 Wireman Gd.1 0.033 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.033 day
MT4544Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 16-Core 1.01 m
CC0100
Coefficient for per m of CC0100
Code Description Quant Units LB0056 Wireman Gd.1 0.034 day LB0067 Painter Gd.2 0.013 day LB0077 Labourer 0.034 day
MT4545Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 19-Core 1.01 m
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 12-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 14-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 16-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 19-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 6-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 7-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 10-Core
Labour and Material Coefficients (Electrical)- 2013 Page 267
Department of Engineering Services, MoWHS
CC0101
Coefficient for per m of CC0101
Code Description Quant Units LB0056 Wireman Gd.1 0.037 day LB0067 Painter Gd.2 0.014 day LB0077 Labourer 0.037 day
MT4546Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 24-Core 1.01 m
CC0102
Coefficient for per m of CC0102
Code Description Quant Units LB0056 Wireman Gd.1 0.037 day LB0067 Painter Gd.2 0.014 day LB0077 Labourer 0.037 day
MT4547Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 27-Core 1.01 m
CC0103
Coefficient for per m of CC0103
Code Description Quant Units LB0056 Wireman Gd.1 0.039 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.039 day
MT4548Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 30-Core 1.01 m
CC0104
Coefficient for per m of CC0104
Code Description Quant Units LB0056 Wireman Gd.1 0.04 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.04 day
MT4549Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 37-Core 1.01 m
CC0105
Coefficient for per m of CC0105
Code Description Quant Units LB0056 Wireman Gd.1 0.039 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.039 day
MT4550Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 44-Core 1.01 m
CC0106
Coefficient for per m of CC0106
Code Description Quant Units LB0056 Wireman Gd.1 0.044 day LB0067 Painter Gd.2 0.017 day LB0077 Labourer 0.044 day
MT4551Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 52-Core 1.01 m
CC0107
Coefficient for per m of CC0107
Code Description Quant Units LB0056 Wireman Gd.1 0.045 day
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 30-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 37-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 44-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 52-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 24-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 27-Core
Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 61-Core
Labour and Material Coefficients (Electrical)- 2013 Page 268
Department of Engineering Services, MoWHS
LB0067 Painter Gd.2 0.017 day LB0077 Labourer 0.045 day
MT4552Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 61-Core 1.01 m
CHAPTER 21: POLE & ACCESSORIES
Coefficient for per each of PA0001
Code Description Quant Units MT6450 Steel Tubular Pole with base plate - 5.5m, 4.5mm thick 1 each
Coefficient for per each of PA0002
Code Description Quant Units MT6451 Steel Tubular Pole with base plate - 5.5m, 4.8mm thick 1 each
Coefficient for per each of PA0003
Code Description Quant Units MT6452 Steel Tubular Pole with base plate - 5.5m, 5.4mm thick 1 each
Coefficient for per each of PA0004
Code Description Quant Units
MT6468Swaged Street Light Steel Tubular Pole (410 MPa) with base plate - 8.5m, 151 kg 1 each
Coefficient for per each of PA0005
Code Description Quant Units
MT6466Swaged Street Light Steel Tubular Pole (410 MPa) with base plate - 8.5m, 148 kg 1 each
Coefficient for per each of PA0006
Code Description Quant Units
MT6467Swaged Street Light Steel Tubular Pole (410 MPa) with base plate -8.5m, 141 kg 1 each
Coefficient for per each of PA0020
Code Description Quant Units LB0024 Lineman Gd.1 0.033 day LB0033 Carpenter Gd.2 0.2106 day LB0036 Mason Gd.1 0.00845 day LB0039 Work Supervisor (Lajab) 0.00676 day LB0051 Mason Gd.2 0.04145 day LB0053 Plant Operator Gd.3 0.00946 day LB0069 Wireman Gd.2 0.033 day
as required - 5.5m, 5.4mm thick
Supplying of street light/compound light MS tubular pole 50/60mm outer dia having a base plate 250x250x5.4mm, entry hole of 40mm dia 1.1m from bottom and strude bolt as earth terminal complete
complete as required - 5.5m, 4.8mm thick
Supplying of street light/compound light MS tubular pole 50/60mm outer dia having a base plate 250x250x5.4mm, entry hole of 40mm dia 1.1m from bottom and strude bolt as earth terminal complete as required - 8.5m, 141kg
PA0006
Errection of steel tubular pole 5.5m length with 40mm dia MS sleeve as inlet of power cable in cement concrete 1:3:6, 40mm stone aggregate foundation with cement concrete base 0.47mx0.47mx75mm thick 1:4:8 including excavation, centering & shuttering, and refilling, providing props for pole etc. complete as required - At dead end
PA0020
Supplying of street light/compound light MS tubular pole 50/60mm outer dia having a base plate 250x250x5.4mm, entry hole of 40mm dia 1.1m from bottom and strude bolt as earth terminal complete as required - 8.5m, 151kg
PA0004
Supplying of street light/compound light MS tubular pole 50/60mm outer dia having a base plate 250x250x5.4mm, entry hole of 40mm dia 1.1m from bottom and strude bolt as earth terminal complete as required - 8.5m, 148kg
PA0005
PA0001
PA0002
PA0003
Supplying of street light/compound light MS tubular pole 50/60mm outer dia having a base plate 250x250x5.4mm, entry hole of 40mm dia 1.1m from bottom and strude bolt as earth terminal complete as required - 5.5m, 4.5mm thick
Supplying of street light/compound light MS tubular pole 50/60mm outer dia having a base plate 250x250x5.4mm, entry hole of 40mm dia 1.1m from bottom and strude bolt as earth terminal
Labour and Material Coefficients (Electrical)- 2013 Page 269
Department of Engineering Services, MoWHS
LB0077 Labourer 0.65518 day MP0001 Concrete Mixer 0.00946 day MP0002 Concrete Vibrator 0.00946 day MT6600 Ballies 75 to 125mm dia 0.567 m MT6601 Rough-sawn timber (Mixed Conifer) 0.01823 cu.m MT6604 Sand 0.06351 cu.m MT6621 Stone Aggregates - 40mm 0.12026 cu.m MT6681 Grey Cement 0.02822 tonne
Coefficient for per each of PA0021
Code Description Quant Units LB0024 Lineman Gd.1 0.033 day LB0033 Carpenter Gd.2 0.2106 day LB0036 Mason Gd.1 0.00835 day LB0039 Work Supervisor (Lajab) 0.00668 day LB0051 Mason Gd.2 0.04135 day LB0053 Plant Operator Gd.3 0.00936 day LB0069 Wireman Gd.2 0.033 day LB0077 Labourer 0.65193 day MP0001 Concrete Mixer 0.00936 day MP0002 Concrete Vibrator 0.00936 day MT6600 Ballies 75 to 125mm dia 0.567 m MT6601 Rough-sawn timber (Mixed Conifer) 0.01823 cu.m MT6604 Sand 0.06282 cu.m MT6621 Stone Aggregates - 40mm 0.11895 cu.m MT6681 Grey Cement 0.0279 tonne
Coefficient for per each of PA0022
Code Description Quant Units LB0024 Lineman Gd.1 0.033 day LB0033 Carpenter Gd.2 0.2106 day LB0036 Mason Gd.1 0.00826 day LB0039 Work Supervisor (Lajab) 0.00661 day LB0051 Mason Gd.2 0.04126 day LB0053 Plant Operator Gd.3 0.00925 day LB0069 Wireman Gd.2 0.033 day LB0077 Labourer 0.65193 day MP0001 Concrete Mixer 0.00925 day MP0002 Concrete Vibrator 0.00925 day MT6600 Ballies 75 to 125mm dia 0.567 m MT6601 Rough-sawn timber (Mixed Conifer) 0.01823 cu.m MT6604 Sand 0.06213 cu.m MT6621 Stone Aggregates - 40mm 0.11764 cu.m MT6681 Grey Cement 0.02757 tonne
Coefficient for per each of PA0035
Code Description Quant Units LB0024 Lineman Gd.1 0.033 day LB0033 Carpenter Gd.2 0.57564 day LB0036 Mason Gd.1 0.03141 day LB0039 Work Supervisor (Lajab) 0.02513 day
1:4:8 including excavation, centering & shuttering, and refilling, providing props for pole etc. complete as required - At dead end
Errection of steel tubular pole 8.5m length with 40mm dia MS sleeve as inlet of power cable in cement concrete 1:3:6, 40mm stone aggregate foundation with cement concrete base 0.47mx0.47mx75mm thick PA0035
Errection of steel tubular pole 5.5m length with 40mm dia MS sleeve as inlet of power cable in cement concrete 1:3:6, 40mm stone aggregate foundation with cement concrete base 0.47mx0.47mx75mm thick 1:4:8 including excavation, centering & shuttering, and refilling, providing props for pole etc. complete as required - At middle
PA0021
Errection of steel tubular pole 5.5m length with 40mm dia MS sleeve as inlet of power cable in cement concrete 1:3:6, 40mm stone aggregate foundation with cement concrete base 0.47mx0.47mx75mm thick 1:4:8 including excavation, centering & shuttering, and refilling, providing props for pole etc. complete as required - Junction of three way
PA0022
Labour and Material Coefficients (Electrical)- 2013 Page 270
Department of Engineering Services, MoWHS
LB0051 Mason Gd.2 0.06441 day LB0053 Plant Operator Gd.3 0.03518 day LB0069 Wireman Gd.2 0.033 day LB0077 Labourer 2.12231 day MP0001 Concrete Mixer 0.03518 day MP0002 Concrete Vibrator 0.03518 day MT6600 Ballies 75 to 125mm dia 1.5498 m MT6601 Rough-sawn timber (Mixed Conifer) 0.04982 cu.m MT6604 Sand 0.23618 cu.m MT6621 Stone Aggregates - 40mm 0.44723 cu.m MT6681 Grey Cement 0.10733 tonne
Coefficient for per each of PA0036
Code Description Quant Units LB0024 Lineman Gd.1 0.033 day LB0033 Carpenter Gd.2 0.57564 day LB0036 Mason Gd.1 0.03141 day LB0039 Work Supervisor (Lajab) 0.02513 day LB0051 Mason Gd.2 0.06441 day LB0053 Plant Operator Gd.3 0.03518 day LB0069 Wireman Gd.2 0.033 day LB0077 Labourer 2.12231 day MP0001 Concrete Mixer 0.03518 day MP0002 Concrete Vibrator 0.03518 day MT6600 Ballies 75 to 125mm dia 1.5498 m MT6601 Rough-sawn timber (Mixed Conifer) 0.04982 cu.m MT6604 Sand 0.23618 cu.m MT6621 Stone Aggregates - 40mm 0.44723 cu.m MT6681 Grey Cement 0.10733 tonne
Coefficient for per each of PA0037
Code Description Quant Units LB0024 Lineman Gd.1 0.033 day LB0033 Carpenter Gd.2 0.57564 day LB0036 Mason Gd.1 0.03141 day LB0039 Work Supervisor (Lajab) 0.02513 day LB0051 Mason Gd.2 0.06441 day LB0053 Plant Operator Gd.3 0.03518 day LB0069 Wireman Gd.2 0.033 day LB0077 Labourer 2.12231 day MP0001 Concrete Mixer 0.03518 day MP0002 Concrete Vibrator 0.03518 day MT6600 Ballies 75 to 125mm dia 1.5498 m MT6601 Rough-sawn timber (Mixed Conifer) 0.04982 cu.m MT6604 Sand 0.23618 cu.m MT6621 Stone Aggregates - 40mm 0.44723 cu.m MT6681 Grey Cement 0.10733 tonne
Coefficient for per each of PA0050
Code Description Quant Units LB0024 Lineman Gd.1 0.333 day
Errection of steel tubular pole 8.5m length with 40mm dia MS sleeve as inlet of power cable in cement concrete 1:3:6, 40mm stone aggregate foundation with cement concrete base 0.47mx0.47mx75mm thick 1:4:8 including excavation, centering & shuttering, and refilling, providing props for pole etc. complete as required - Junction of three way
PA0037
Errection of junction box and pole cap with arm bracket including wiring with PVC insulated copper conductor cable 1.1KV grade 2x2.5 sq.mm through the existing pole and arm bracket from junction box including erection of street light fixtures, lamps, connection, testing etc. complete as required - Single arm
PA0050
Errection of steel tubular pole 8.5m length with 40mm dia MS sleeve as inlet of power cable in cement concrete 1:3:6, 40mm stone aggregate foundation with cement concrete base 0.47mx0.47mx75mm thick 1:4:8 including excavation, centering & shuttering, and refilling, providing props for pole etc. complete as required - At middle
PA0036
Labour and Material Coefficients (Electrical)- 2013 Page 271
Department of Engineering Services, MoWHS
LB0032 Blacksmith (metal-worker) 0.111 day LB0056 Wireman Gd.1 0.333 day LB0069 Wireman Gd.2 0.333 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17 m MT6637 Rolled Steel Section 250MPa - Flats 0.455 kg
Coefficient for per each of PA0051
Code Description Quant Units LB0024 Lineman Gd.1 0.5 day LB0032 Blacksmith (metal-worker) 0.111 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 26 m MT6637 Rolled Steel Section 250MPa - Flats 0.455 kg
Coefficient for per each of PA0052
Code Description Quant Units LB0024 Lineman Gd.1 0.75 day LB0032 Blacksmith (metal-worker) 0.111 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 0.75 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 35 m MT6637 Rolled Steel Section 250MPa - Flats 0.455 kg
Coefficient for per each of PA0065
Code Description Quant Units LB0024 Lineman Gd.1 0.125 day LB0032 Blacksmith (metal-worker) 0.0833 day LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10 m MT6637 Rolled Steel Section 250MPa - Flats 0.145 kg
PA0075
Coefficient for per each of PA0075
Code Description Quant Units LB0056 Wireman Gd.1 0.167 day LB0069 Wireman Gd.2 0.167 day LB0077 Labourer 1.88053 day MT6530 Wire - GI, 4mm dia (8swg) 5 m MT6557 Accessories - G.I Spike 1.8m 1 each
PA0076
Coefficient for per each of PA0076
Code Description Quant Units LB0056 Wireman Gd.1 0.2 day
Erection of post lamp fixtures including wiring with PVC insulated copper conductor cable 1.1KV grade 2x1.5 sq.mm through the existing pole from junction box including erection of post top lamp fixtures, lamps, connection, testing etc. complete as required - Post top lamp fixtures
PA0065
Providing and installation of street/compound light pole earthing including connections, testing etc. complete as required including excavation and refilling - With G.I earth spike 1.8m
Providing and installation of street/compound light pole earthing including connections, testing etc. complete as required including excavation and refilling - With G.I Wire 8 SWG
Errection of junction box and pole cap with arm bracket including wiring with PVC insulated copper conductor cable 1.1KV grade 2x2.5 sq.mm through the existing pole and arm bracket from junction box including erection of street light fixtures, lamps, connection, testing etc. complete as required - Double arm
PA0051
Errection of junction box and pole cap with arm bracket including wiring with PVC insulated copper conductor cable 1.1KV grade 2x2.5 sq.mm through the existing pole and arm bracket from junction box including erection of street light fixtures, lamps, connection, testing etc. complete as required - Triple arm
PA0052
Labour and Material Coefficients (Electrical)- 2013 Page 272
Department of Engineering Services, MoWHS
LB0069 Wireman Gd.2 0.2 day LB0077 Labourer 1.88053 day MT6530 Wire - GI, 4mm dia (8swg) 12 m
PA0090
Coefficient for per each of PA0090
Code Description Quant Units MT6480 Pole cap wih arm bracket 1.1m and outer dia 50/60mm - Single arm 1 each
PA0091
Coefficient for per each of PA0091
Code Description Quant Units MT6481 Pole cap wih arm bracket 1.1m and outer dia 50/60mm - Double arm 1 each
PA0092
Coefficient for per each of PA0092
Code Description Quant Units MT6482 Pole cap wih arm bracket 1.1m and outer dia 50/60mm - Triple arm 1 each
Coefficient for per each of PA0105
Code Description Quant Units MT6495 MS junction box out door duty, fabricated with 14SWG MS sheet 1 each
CHAPTER 22: TELEPHONE WIRES & CABLES
TC0001
Coefficient for per each of TC0001
Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4595 Telephone wire 0.5mm dia, PVC insulated & sheathed, copper - 2 pair 1.01 m
TC0002
Coefficient for per each of TC0002
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4596 Telephone wire 0.5mm dia, PVC insulated & sheathed, copper - 5 pair 1.01 m
Coefficient for per each of TC0010
Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4610 Telecommunication Cable 0.5mm dia unarmoured, PVC insulated & sheathed, 1.01 m pair
20 pair
Provide and draw PVC insulated & sheathed copper conductor 0.5mm dia telephone wire in existing surface/ recessed conduit wiring system complete as required - 5 pair
Provide and draw PVC insulated & sheathed copper conductor 0.5mm dia telephone wire in existing surface/ recessed conduit wiring system complete as required - 2 pair
PA0105
TC0010
Supplying of pole cap with arm bracket 1.1m long and outer dia 50/60mm having inner pole and outer tightened bolt etc. complete as required for the top section of pole - Double arm
Supplying of pole cap with arm bracket 1.1m long and outer dia 50/60mm having inner pole and outer tightened bolt etc. complete as required for the top section of pole - Triple arm
Provide and draw Jelly filled Telecommunication cables PVC insulated & sheathed copper conductor 0.5mm dia unarmoured in existing surface/ recessed conduit wiring system complete as required -
Supplying of junction box fabricated with 14SWG MS sheet, removal cover plate with gasket for dust and vermine proof, 2 earthing terminals with nut, bolts and spring washer, 2 entry holes 16mm dia at bottom,32mm dia for cable entry at back , including 4 way terminal block & HRC fuse unit with fuse of 6A with locking arrangement and finish coat painting complete with all accessories as required as per standard drawing - MS junction box out door duty
Supplying of pole cap with arm bracket 1.1m long and outer dia 50/60mm having inner pole and outer tightened bolt etc. complete as required for the top section of pole - Single arm
Labour and Material Coefficients (Electrical)- 2013 Page 273
Department of Engineering Services, MoWHS
Coefficient for per each of TC0011
Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4611 Telecommunication Cable 0.5mm dia unarmoured, PVC insulated & sheathed, 1.01 m pair
Coefficient for per each of TC0012
Code Description Quant Units LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4612 Telecommunication Cable 0.5mm dia unarmoured, PVC insulated & sheathed, 1.01 m pair
Coefficient for per each of TC0020
Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0069 Wireman Gd.2 0.024 day MT4625 Telecommunication Cable 0.5mm dia armoured, PVC insulated & sheathed, co 1.01 m
Coefficient for per each of TC0021
Code Description Quant Units LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4626 Telecommunication Cable 0.5mm dia armoured, PVC insulated & sheathed, co 1.01 m
Coefficient for per each of TC0022
Code Description Quant Units LB0056 Wireman Gd.1 0.044 day LB0069 Wireman Gd.2 0.044 day MT4627 Telecommunication Cable 0.5mm dia armoured, PVC insulated & sheathed, co 1.01 m pair
CHAPTER 23: AIR CONDITIONERS
AC0001 Coefficient for per each of AC0001
Code Description Quant Units LB0021 Carpenter Gd.1 1 day LB0077 Labourer 1 day MT6567 Window Type - 1 tonne 1 each
Provide and draw Jelly filled Telecommunication cables PVC insulated & sheathed copper conductor 0.5mm dia unarmoured in existing surface/ recessed conduit wiring system complete as required -
100 pair TC0022
Providing & fixing Window Type Air Conditioners - 1 tonne, window type
20 pair TC0020
Provide and draw Jelly filled Telecommunication cables PVC insulated & sheathed copper conductor 0.5mm dia armoured in existing surface/ recessed conduit wiring system complete as required - 50 pair
TC0021
Provide and draw Jelly filled Telecommunication cables PVC insulated & sheathed copper conductor 0.5mm dia armoured in existing surface/ recessed conduit wiring system complete as required -
50 pair TC0011
Provide and draw Jelly filled Telecommunication cables PVC insulated & sheathed copper conductor 0.5mm dia unarmoured in existing surface/ recessed conduit wiring system complete as required - 100 pair
TC0012
Provide and draw Jelly filled Telecommunication cables PVC insulated & sheathed copper conductor 0.5mm dia armoured in existing surface/ recessed conduit wiring system complete as required -
Labour and Material Coefficients (Electrical)- 2013 Page 274
Department of Engineering Services, MoWHS
AC0002 Coefficient for per each of AC0002
Code Description Quant Units LB0021 Carpenter Gd.1 1 day LB0077 Labourer 1 day MT6566 Window Type - 1.5 tonne 1 each AC0003 Coefficient for per each of AC0003
Code Description Quant Units LB0021 Carpenter Gd.1 1 day LB0077 Labourer 1 day MT6565 Window Type - 2 tonne 1 each AC0015 Coefficient for per each of AC0015
Code Description Quant Units LB0021 Carpenter Gd.1 1 day LB0077 Labourer 1 day MT6587 Splite Type - 1 tonne 1 each AC0016 Coefficient for per each of AC0016
Code Description Quant Units LB0021 Carpenter Gd.1 1 day LB0077 Labourer 1 day MT6586 Splite Type - 1.5 tonne 1 each AC0017 Coefficient for per each of AC0017
Code Description Quant Units LB0021 Carpenter Gd.1 1 day LB0077 Labourer (Male) 1 day MT6585 Splite Type - 2 tonne 1 each
CHAPTER 24: DISMANTLING & DEMOLITION
Coefficient for per point of DS0001
Code Description Quant Units LB0024 Lineman Gd.1 0.0625 day LB0077 Labourer 0.1875 day
Coefficient for per point of DS0002
Code Description Quant Units LB0024 Lineman Gd.1 0.125 day LB0077 Labourer 0.375 day
Dismantling of Electrical wiring including conduits for light, fan, Exhaust fan, call bell, 3 pin 5 ampere plug point, circuit / submain wiring etc and stacking materials within 50m lead including making the surface good: - medium point
DS0002
Dismantling of Electrical wiring including conduits for light, fan, Exhaust fan, call bell, 3 pin 5 ampere plug point, circuit /submain wiring etc and stacking materials within 50m lead including the
Providing & fixing Window Type Air Conditioners - 2 tonne, window type
Providing & fixing Split Type Air Conditioners - 1 tonne, split type
surface good: - short point DS0001
Providing & fixing Window Type Air Conditioners - 1.5 tonne, window type
Providing & fixing Split Type Air Conditioners - 1.5 tonne, split typ
Providing & fixing Split Type Air Conditioners - 2 tonne, split type
Labour and Material Coefficients (Electrical)- 2013 Page 275
Department of Engineering Services, MoWHS
Coefficient for per point of DS0003
Code Description Quant Units LB0024 Lineman Gd.1 0.1875 day LB0077 Labourer 0.5714 day
Coefficient for per m of DS0004
Code Description Quant Units LB0024 Lineman Gd.1 0.045 day LB0077 Labourer 0.0675 day
DS0015
Coefficient for per each of DS0015
Code Description Quant Units LB0024 Lineman Gd.1 0.021 day LB0077 Labourer 0.03125 day
CHAPTER 25: CIVIL WORK
CV0001
Coefficient for per sq.m of CV0001
Code Description Quant Units LB0077 Labourer 0.0339 day
CV0002
Coefficient for per sq.m of CV0002
Code Description Quant Units LB0077 Labourer 0.0476 day
CV0015
Coefficient for per cu.m of CV0015
Code Description Quant Units LB0077 Labourer 0.4588 day
CV0016
Coefficient for per cu.m of CV0016
Code Description Quant Units LB0077 Labourer 0.588 day
CV0017
Coefficient for per cu.m of CV0017
Code Description Quant Units LB0077 Labourer 1.6838 day
Excavation in foundation trenches or drains, width <1.5m, area <10 sq.m in plan, depth >300mm including dressing & ramming, disposal of surplus soil within 50m lead & 1.5m lift - Ordinary Soil
Excavation in foundation trenches or drains, width <1.5m, area <10 sq.m in plan, depth >300mm including dressing & ramming, disposal of surplus soil within 50m lead & 1.5m lift - Hard Soil
Excavation in foundation trenches or drains, width <1.5m, area <10 sq.m in plan, depth >300mm including dressing & ramming, disposal of surplus soil within 50m lead & 1.5m lift - Ordinary rock with out blasting
making the surface good: - Circuit, submain wiring, general wiring
Dismantling of Electrical wiring including conduits for light, fan, Exhaust fan, call bell, 3 pin 5 ampere plug point, circuit /submain wiring etc and stacking materials within 50m lead includingDS0004
Dismantling Electrical fittings, boxes, covers, etc all types and stacking materials within 50m lead including making the surface good: - Pendent/ recessed/ surface
Surface dressing of ground, including removal of vegetations and inequalities < 150mm deep, disposal of rubbish within 50m lead and 1.5m lifts - Ordinary Soil
Surface dressing of ground, including removal of vegetations and inequalities < 150mm deep, disposal of rubbish within 50m lead and 1.5m lifts - Hard Soil
Dismantling of Electrical wiring including conduits for light, fan, Exhaust fan, call bell, 3 pin 5 ampere plug point, circuit /submain wiring etc and stacking materials within 50m lead icludingmaking the surface good: - long point
DS0003
Labour and Material Coefficients (Electrical)- 2013 Page 276
Department of Engineering Services, MoWHS
CV0018
Coefficient for per cu.m of CV0018
Code Description Quant Units LB0032 Blacksmith (metal-worker) 0.044 day LB0051 Mason Gd.2 0.265 day LB0077 Labourer 3.3163 day
Coefficient for per m of CV0030
Code Description Quant Units LB0077 Labourer 0.58232 day
Coefficient for per m of CV0031
Code Description Quant Units LB0077 Labourer 0.90893 day
Coefficient for per m of CV0045
Code Description Quant Units LB0077 Labourer 0.68207 day
Coefficient for per m of CV0046
Code Description Quant Units LB0077 Labourer 1.06462 day
Coefficient for per m of CV0060
Code Description Quant Units LB0077 Labourer 2.35878 day
Coefficient for per m of CV0061
Code Description Quant Units LB0077 Labourer 2.71413 day
Coefficient for per m of CV0075
Code Description Quant Units LB0032 Blacksmith (metal-worker) 0.05148 day LB0051 Mason Gd.2 0.31005 day LB0077 Labourer 4.26881 day
of 50m: Hard Soil - Pipes, cables etc. 80mm to 300mm dia
Hand excavation and refilling in layers < 200mm, of trenches for pipes & sockets, cables, including dressing of sides/ ramming of bottom, depth upto 1.5m, disposal of surplus material within lead
of 50m: Ordinary Soil - Pipes, cables etc. > 300mm dia
Hand excavation and refilling in layers < 200mm, of trenches for pipes & sockets, cables, including dressing of sides/ ramming of bottom, depth upto 1.5m, disposal of surplus material within lead
Hand excavation and refilling in layers < 200mm, of trenches for pipes & sockets, cables, including dressing of sides/ ramming of bottom, depth upto 1.5m, disposal of surplus material within lead of 50m: Ordinary rock - Pipes, cables etc. > 300mm dia
CV0061
Hand excavation and refilling in layers < 200mm, of trenches for pipes & sockets, cables, including dressing of sides/ ramming of bottom, depth upto 1.5m, disposal of surplus material within lead of 50m: Hard rock requiring chiselling - Pipes, cables etc. 80mm to 300mm dia
CV0075
Hand excavation and refilling in layers < 200mm, of trenches for pipes & sockets, cables, including dressing of sides/ ramming of bottom, depth upto 1.5m, disposal of surplus material within lead of 50m: Hard Soil - Pipes, cables etc. > 300mm dia
CV0046
Hand excavation and refilling in layers < 200mm, of trenches for pipes & sockets, cables, including dressing of sides/ ramming of bottom, depth upto 1.5m, disposal of surplus material within lead of 50m: Ordinary rock - Pipes, cables etc. 80mm to 300mm dia
CV0060
CV0030
CV0031
CV0045
Excavation in foundation trenches or drains, width <1.5m, area <10 sq.m in plan, depth >300mm including dressing & ramming, disposal of surplus soil within 50m lead & 1.5m lift - Hard rock requiring chiselling
Hand excavation and refilling in layers < 200mm, of trenches for pipes & sockets, cables, including dressing of sides/ ramming of bottom, depth upto 1.5m, disposal of surplus material within lead of 50m: Ordinary Soil - Pipes, cables etc. 80mm to 300mm dia
Labour and Material Coefficients (Electrical)- 2013 Page 277
Department of Engineering Services, MoWHS
Coefficient for per m of CV0076
Code Description Quant Units LB0032 Blacksmith (metal-worker) 0.05925 day LB0051 Mason Gd.2 0.35685 day LB0077 Labourer 4.91245 day CV0090 Coefficient for per cu.m of CV0090
Code Description Quant Units LB0077 Labourer 0.2955 day CV0091 Coefficient for per cu.m of CV0091
Code Description Quant Units LB0077 Labourer 0.2888 day MT6604 Sand 1 cu.m
CV0105
Coefficient for per sq.m of CV0105
Code Description Quant Units LB0033 Carpenter Gd.2 0.0033 day LB0077 Labourer 0.0069 day MT6600 Ballies 75 to 125mm dia 0.2833 m MT6601 Rough-sawn timber (Mixed Conifer) 0.0087 cu.m
CV0106
Coefficient for per sq.m of CV0106
Code Description Quant Units LB0033 Carpenter Gd.2 0.0069 day LB0077 Labourer 0.0136 day MT6600 Ballies 75 to 125mm dia 0.2833 m MT6601 Rough-sawn timber (Mixed Conifer) 0.0087 cu.m
CV0107
Coefficient for per sq.m of CV0107
Code Description Quant Units LB0033 Carpenter Gd.2 0.0139 day LB0077 Labourer 0.0244 day MT6600 Ballies 75 to 125mm dia 0.2833 m MT6601 Rough-sawn timber (Mixed Conifer) 0.0087 cu.m
CV0120
Coefficient for per sq.m of CV0120
Code Description Quant Units LB0033 Carpenter Gd.2 0.0069 day LB0077 Labourer 0.0139 day MT6600 Ballies 75 to 125mm dia 0.2833 m MT6601 Rough-sawn timber (Mixed Conifer) 0.0257 cu.m
Hand excavation and refilling in layers < 200mm, of trenches for pipes & sockets, cables, including dressing of sides/ ramming of bottom, depth upto 1.5m, disposal of surplus material within lead of 50m: Hard rock requiring chiselling - Pipes, cables etc. > 300mm dia
CV0076
Using selected excavated earth
Using sand
Open timbering over areas including lagging & strutting of trenches, cuts (per sq.m face area timbered) - Depth not exceeding
Open timbering over areas including lagging & strutting of trenches, cuts (per sq.m face area timbered)- 1.5m < depth < 3 m
Open timbering over areas including lagging & strutting of trenches, cuts (per sq.m face area timbered)- Depth > 3 m
Close timbering over areas including lagging & strutting of trenches, cuts ( per sq.m face area timbered)- Depth not exceeding
Labour and Material Coefficients (Electrical)- 2013 Page 278
Department of Engineering Services, MoWHS
CV0121
Coefficient for per sq.m of CV0121
Code Description Quant Units LB0033 Carpenter Gd.2 0.01385 day LB0077 Labourer 0.035 day MT6600 Ballies 75 to 125mm dia 0.2833 m MT6601 Rough-sawn timber (Mixed Conifer) 0.0257 cu.m
CV0122
Coefficient for per sq.m of CV0122
Code Description Quant Units LB0033 Carpenter Gd.2 0.0208 day LB0077 Labourer 0.056 day MT6600 Ballies 75 to 125mm dia 0.2833 m MT6601 Rough-sawn timber (Mixed Conifer) 0.0257 cu.m
CV0135
Coefficient for per cu.m of CV0135
Code Description Quant Units LB0036 Mason Gd.1 0.0625 day LB0039 Work Supervisor (Lajab) 0.05 day LB0051 Mason Gd.2 0.0625 day LB0053 Plant Operator Gd.3 0.07 day LB0077 Labourer 2.2125 day MP0001 Concrete Mixer 0.07 day MP0002 Concrete Vibrator 0.07 day MT6604 Sand 0.445 cu.m MT6623 Stone Aggregates - 20mm 0.89 cu.m MT6681 Grey Cement 0.3213 tonne
CV0136
Coefficient for per cu.m of CV0136
Code Description Quant Units LB0036 Mason Gd.1 0.0625 day LB0039 Work Supervisor (Lajab) 0.05 day LB0051 Mason Gd.2 0.0625 day LB0053 Plant Operator Gd.3 0.07 day LB0077 Labourer 2.2125 day MP0001 Concrete Mixer 0.07 day MP0002 Concrete Vibrator 0.07 day MT6604 Sand 0.445 cu.m MT6621 Stone Aggregates - 40mm 0.89 cu.m MT6681 Grey Cement 0.3213 tonne
CV0137
Coefficient for per cu.m of CV0137
Code Description Quant Units LB0036 Mason Gd.1 0.0625 day LB0039 Work Supervisor (Lajab) 0.05 day LB0051 Mason Gd.2 0.0625 day LB0053 Plant Operator Gd.3 0.07 day LB0077 Labourer 2.2125 day MP0001 Concrete Mixer 0.07 day MP0002 Concrete Vibrator 0.07 day MT6604 Sand 0.47 cu.m MT6621 Stone Aggregates - 40mm 0.89 cu.m MT6681 Grey Cement 0.22 tonne
Close timbering over areas including lagging & strutting of trenches, cuts ( per sq.m face area timbered)- 1.5m < depth < 3m
Close timbering over areas including lagging & strutting of trenches, cuts ( per sq.m face area timbered)- 3m < depth < 4.5m
Providing &laying cement concrete excluding the cost of centering and shuttering - 1:2:4, 20mm aggregates
Providing &laying cement concrete excluding the cost of centering and shuttering - 1:2:4, 40mm aggregates
Providing &laying cement concrete excluding the cost of centering and shuttering - 1:3:6, 40mm aggregates
Labour and Material Coefficients (Electrical)- 2013 Page 279
Department of Engineering Services, MoWHS
CV0138
Coefficient for per cu.m of CV0138
Code Description Quant Units LB0036 Mason Gd.1 0.0625 day LB0039 Work Supervisor (Lajab) 0.05 day LB0051 Mason Gd.2 0.0625 day LB0053 Plant Operator Gd.3 0.07 day LB0077 Labourer 2.2125 day MP0001 Concrete Mixer 0.07 day MP0002 Concrete Vibrator 0.07 day MT6604 Sand 0.47 cu.m MT6620 Stone Aggregates - 50mm 0.89 cu.m MT6681 Grey Cement 0.17 tonne
CV0139
Coefficient for per cu.m of CV0139
Code Description Quant Units LB0036 Mason Gd.1 0.0625 day LB0039 Work Supervisor (Lajab) 0.05 day LB0051 Mason Gd.2 0.0625 day LB0053 Plant Operator Gd.3 0.07 day LB0077 Labourer 2.2125 day MP0001 Concrete Mixer 0.07 day MP0002 Concrete Vibrator 0.07 day MT6604 Sand 0.47 cu.m MT6620 Stone Aggregates - 50mm 0.89 cu.m MT6681 Grey Cement 0.131 tonne
CV0140
Coefficient for per cu.m of CV0140
Code Description Quant Units LB0036 Mason Gd.1 0.0625 day LB0039 Work Supervisor (Lajab) 0.05 day LB0051 Mason Gd.2 0.0625 day LB0053 Plant Operator Gd.3 0.07 day LB0077 Labourer 2.2125 day MP0001 Concrete Mixer 0.07 day MP0002 Concrete Vibrator 0.07 day MT6604 Sand 0.47 cu.m MT6621 Stone Aggregates - 40mm 0.89 cu.m MT6681 Grey Cement 0.131 tonne
CV0150
Coefficient for per sq.m of CV0150
Code Description Quant Units LB0033 Carpenter Gd.2 0.156 day LB0077 Labourer 0.156 day MT6600 Ballies 75 to 125mm dia 0.42 m MT6601 Rough-sawn timber (Mixed Conifer) 0.0135 cu.m CV0160 Coefficient for per cu.m of CV0160
Code Description Quant Units LB0036 Mason Gd.1 0.339 day
Providing &laying cement concrete excluding the cost of centering and shuttering - 1:3:6, 50mm aggregates
Providing &laying cement concrete excluding the cost of centering and shuttering - 1:5:10, 50mm aggregates
Providing &laying cement concrete excluding the cost of centering and shuttering - 1:5:10, 40mm aggregates
Providing and laying second class brick work in foundation and plinth - In cement mortar 1:4
Providing & fixing centering and shuttering (formwork), including strutting, propping etc. and removal of formwork - Foundation and plinth
Labour and Material Coefficients (Electrical)- 2013 Page 280
Department of Engineering Services, MoWHS
LB0051 Mason Gd.2 0.339 day LB0077 Labourer 1.87025 day MT6604 Sand 0.2675 cu.m MT6680 Bricks 2nd class 0.407 1000# MT6681 Grey Cement 0.095 tonne CV0170 Coefficient for per sq.m of CV0170
Code Description Quant Units LB0036 Mason Gd.1 0.102 day LB0077 Labourer 0.1512 day MT6604 Sand 0.01541 cu.m MT6681 Grey Cement 0.0036 tonne CV0180 Coefficient for per cu.m of CV0180
Code Description Quant Units LB0077 Labourer (Male) 1.125 day MT6604 Sand 1.07 cu.m MT6681 Grey Cement 0.38 tonne CV0181 Coefficient for per cu.m of CV0181
Code Description Quant Units LB0077 Labourer 1.125 day MT6604 Sand 1.07 cu.m MT6681 Grey Cement 0.25 tonne
Cement mortar 1:4
Providing & laying 12mm cement plaster - In cement mortar 1:6
Cement mortar 1:6