MINISTRY OF WORKS AND HUMAN SETTLEMENT

DEPARTMENT OF ENGINEERING SERVICES LABOUR AND MATERIAL CO-EFFICIENTS

(ELECTRICAL) 2013

Page 3: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical) - 2013

Foreword

The Labour and Material Co-efficient (LMC) published by the Department of EngineeringServices under the Ministry of Works and Human Settlement forms an integral part of BhutanSchedule of Rates. The built-up rates of the BSR are corresponding to the coefficients asindicated in this document.

This book is a guideline for preparation of rate analysis for those items of work which are similarin nature. Due to rapid change in construction technology, a need to review and updatemachinery and labour coefficient is also felt. Until such system is established where latest bestpractices can be easily adopted, LMC shall continue to remain unchanged. However,individuals/agencies are advised to carefully review the coefficients and apply it at their owndiscretions.

I am positive ~hat this Analysis of Rates will be useful to all concerned.

Dr. Sonam TenzinSecretary,Ministry of Works and Human SettlementThimphu.

Date: ~~ 10> \ 'U) I~

Department of Engineering Services page 3

Page 4: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical) - 2013  

Department of Engineering Services  page 4  

Disclaimer

The BSR (Both Civil & Electrical) ‐2013 is prepared and published primarily as a tool to assist in

estimation of project costs. Due to difficulty in obtaining comprehensive and accurate rates from

FOUR base towns, and associated complexity in their analysis, the BSR reflects only suggestive

averages and not accurate current market rates. Material and labour rates are subject to change any

time as they are totally governed by market forces which are beyond the control of any

individual/group/organization. The validity of rates in the BSR is therefore uncertain and by the

time of publication of this book, some rates would have already altered. Hence engineers,

architects, contractors and all other relevant professionals/firms in the construction industry are

advised to carry out thorough assessment of materials to be used and after conducting their own

market studies, analyse the rates and prepare cost estimates. The publisher shall not be held

accountable or answerable for any issues/disputes arising as a result of individuals or agencies using

the rates in the BSR‐2013 as a basis for filling their bids, evaluating and awarding of tenders.

Furthermore, the BSR shall not be used for purpose of any contractual payments.

©All rights reserved with DES, MoWHS. Reproduction for sale of this publication, in part(s) or

whole, in any form or by any means, by any agency or individual, is a punishable offence and is

strictly prohibited.

Page 5: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013

Department of Engineering Services, MoWHS

CONTENTS

1 Foreword 3

2 Disclaimer 4

3 PVC Casing & Capping Wiring 7

4 Trunking Cable Management Wiring 26

5 MS Conduit Wiring 33

6 PVC Conduit Wiring 66

7 Stainless Steel Conduit Wiring 103

8 Re-Wiring 120

9 Conduiting 135

10 Boxes 159

11 Switches & Sockets 165

12 Indoor Luminiaries (Supply) 179

13 Outdoor Luminiaries (Supply) 183

14 Lamps & Shades 187

15 Fans (Supply) 191

16 Control Gear & Busbars (Supply) 192

17 Erection / Installation 213

18 Earthing 230

19 Lightning Protection 234

20 Power Cable (Supply) 235

21 Laying of Power Cable 250

22 Control Cable 257

23 Electric Pole & Accessories 268

24 Telephone Wires & Cables 272

25 Air Conditioners 273

26 Dismantling & Demolition 274

27 Civil Works 275

Chapter Description Page

Page 6: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 7

Department of Engineering Services, MoWHS

WP0001

Coefficient for per m of WP0001

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 1.01 m

WP0002

Coefficient for per m of WP0002

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 2.02 m

WP0003

Coefficient for per m of WP0003

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 3.03 m

WP0004

Coefficient for per m of WP0004

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 4.04 m

WP0005

Coefficient for per m of WP0005

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 5.05 m

WP0006

Coefficient for per m of WP0006

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 6.06 m

WP0007

Coefficient for per m of WP0007

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 7.07 m

CHAPTER 1: PVC CASING & CAPPING WIRING

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 4x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 5x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 6x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 1x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 3x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 2x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 7x1.5 sq.mm

Page 7: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 8

Department of Engineering Services, MoWHS

WP0008

Coefficient for per m of WP0008

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 8.08 m

WP0009

Coefficient for per m of WP0009

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 2.02 m

WP0010

Coefficient for per m of WP0010

Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 3.03 m

WP0011

Coefficient for per m of WP0011

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 4.04 m

WP0012

Coefficient for per m of WP0012

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 5.05 m

WP0013

Coefficient for per m of WP0013

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 6.06 m

WP0014

Coefficient for per m of WP0014

Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 2.02 m

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 5x2.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 6x2.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 2x4 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 3x2.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 4x2.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 8x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 2x2.5 sq.mm

Page 8: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 9

Department of Engineering Services, MoWHS

WP0015

Coefficient for per m of WP0015

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 3.03 m

WP0016

Coefficient for per m of WP0016

Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.027 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 4.04 m

WP0017

Coefficient for per m of WP0017

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 5.05 m

WP0018

Coefficient for per m of WP0018

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 2.02 m

WP0019

Coefficient for per m of WP0019

Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.027 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 3.0302 m

WP0020

Coefficient for per m of WP0020

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 4.04 m

WP0040

Coefficient for per m of WP0040

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 1.01 m

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 4x6 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 1x1 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 5x4 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 3x4 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 4x4 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 2x6 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC Casing Capping - 3x6 sq.mm

Page 9: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 10

Department of Engineering Services, MoWHS

WP0041

Coefficient for per m of WP0041

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m

WP0042

Coefficient for per m of WP0042

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 3.03 m

WP0043

Coefficient for per m of WP0043

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.04 m

WP0044

Coefficient for per m of WP0044

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 5.05 m

WP0045

Coefficient for per m of WP0045

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.06 m

WP0046

Coefficient for per m of WP0046

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 7.07 m

WP0047

Coefficient for per m of WP0047

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 8.08 m

WP0048

Coefficient for per m of WP0048

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 9.09 m

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 3x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 4x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 5x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 6x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 7x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 2x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 8x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 9x1 sq.mm

Page 10: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 11

Department of Engineering Services, MoWHS

WP0049

Coefficient for per m of WP0049

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m

WP0050

Coefficient for per m of WP0050

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 3.03 m

WP0051

Coefficient for per m of WP0051

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.04 m

WP0052

Coefficient for per m of WP0052

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 5.05 m

WP0053

Coefficient for per m of WP0053

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.06 m

WP0054

Coefficient for per m of WP0054

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 7.07 m

WP0055

Coefficient for per m of WP0055

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 8.08 m

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 4x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 5x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 6x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 7x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 2x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 3x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 8x1.5 sq.mm

Page 11: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 12

Department of Engineering Services, MoWHS

WP0056

Coefficient for per m of WP0056

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m

WP0057

Coefficient for per m of WP0057

Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 3.03 m

WP0058

Coefficient for per m of WP0058

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.04 m

WP0059

Coefficient for per m of WP0059

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 5.05 m

WP0060

Coefficient for per m of WP0060

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 6.06 m

WP0061

Coefficient for per m of WP0060

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m

WP0062

Coefficient for per m of WP0062

Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 3.03 m

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 5x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 6x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 2x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 3x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 2x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 3x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 4x2 sq.mm

Page 12: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 13

Department of Engineering Services, MoWHS

WP0063

Coefficient for per m of WP0063

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.04 m

WP0064

Coefficient for per m of WP0064

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 5.05 m

WP0065

Coefficient for per m of WP0065

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 6.06 m

WP0066

Coefficient for per m of WP0066

Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m

WP0067

Coefficient for per m of WP0067

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 3.03 m

WP0068

Coefficient for per m of WP0068

Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.027 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.04 m

WP0069

Coefficient for per m of WP0069

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 5.05 m

WP0070

Coefficient for per m of WP0070

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 3x4 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 4x4 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 5x4 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 2x6 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 4x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 5x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 6x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 2x4 sq.mm

Page 13: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 14

Department of Engineering Services, MoWHS

WP0071

Coefficient for per m of WP0071

Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.027 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 3.0302 m

WP0072

Coefficient for per m of WP0072

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m

Coefficient for per point of WP0095

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WP0096

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

WP0095

WP0096etc. as required - Medium Point

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 3x6 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated Copper conductor cable in existing PVC Casing Capping - 4x6 sq.mm

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - Short Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning

Page 14: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 15

Department of Engineering Services, MoWHS

Coefficient for per point of WP0097

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WP0105

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

etc. as required - Medium Point Coefficient for per point of WP0106

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

WP0106

WP0097

WP0105Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning

etc. as required - Long Point

etc. as required - Short Point

Page 15: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 16

Department of Engineering Services, MoWHS

Coefficient for per point of WP0107

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WP0115

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WP0116

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each

WP0107

WP0115

etc. as required - Long Point

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including

earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

WP0116earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning

Page 16: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 17

Department of Engineering Services, MoWHS

Coefficient for per point of WP0117

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4940 PVC Casing & Cappings - 12x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WP0125

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4941 PVC Casing & Cappings - 12x10 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WP0126

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4941 PVC Casing & Cappings - 12x10 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3/5 pin, 6 ampere socket outlet and switch

WP0125

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3/5 pin, 6 ampere socket outlet and switch

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WP0126

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3/5 pin, 6 ampere socket outlet and switch includingWP0117earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

Page 17: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 18

Department of Engineering Services, MoWHS

Coefficient for per point of WP0127

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4941 PVC Casing & Cappings - 12x10 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WP0135

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m

MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WP0136

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m

MT5825 Plate 4-module with frame 1 each

WP0135

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3 pin, 6/16 ampere socket outlet and switch

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3/5 pin, 6 ampere socket outlet and switch

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

WP0136

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

WP0127

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3 pin, 6/16 ampere socket outlet and switch

Page 18: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 19

Department of Engineering Services, MoWHS

Coefficient for per point of WP0137

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WP0145

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WP0146

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each

WP0137

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

WP0145

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WP0146

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3 pin, 6/16 ampere socket outlet and switchincluding earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

Page 19: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 20

Department of Engineering Services, MoWHS

Coefficient for per point of WP0147

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WP0155

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WP0156

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each

WP0147

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

WP0155

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WP0156

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required- Long Point

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3 pin, 16 ampere socket outlet and switch

Page 20: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 21

Department of Engineering Services, MoWHS

Coefficient for per point of WP0157

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WP0165

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WP0166

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each

Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WP0166

WP0165Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with 2 way 6 ampere switch including earthing third pin, connections, painting, testing, and

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

WP0157

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with providing and fixing 3 pin, 16 ampere socket outlet and switch

commissioning etc. as required - Short Point

Page 21: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 22

Department of Engineering Services, MoWHS

Coefficient for per point of WP0167

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WP0175

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WP0176

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Medium Point

WP0176

Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with 2 way 6 ampere switch including earthing third pin, connections, painting, testing

commissioning etc. as required - Short Point WP0175

and commissioning etc. as required - Long Point WP0167

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with 2 way 6 ampere switch including connections, painting, testing and

Page 22: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 23

Department of Engineering Services, MoWHS

Coefficient for per point of WP0177

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4944 PVC Casing & Cappings - 20x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 1 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per m of WP0185

Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4940 PVC Casing & Cappings - 12x12 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m

Coefficient for per m of WP0186

Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4940 PVC Casing & Cappings - 12x12 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m

Coefficient for per m of WP0187

Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4944 PVC Casing & Cappings - 20x12 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m

required - 2x1.5 sq.mm WP0186

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm

WP0187

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as

required - 2x1 sq.mm WP0185

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Long Point

WP0177

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as

Page 23: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 24

Department of Engineering Services, MoWHS

WP0195

Coefficient for per m of WP0195

Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4940 PVC Casing & Cappings - 12x12 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m

WP0196

Coefficient for per m of WP0196

Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4944 PVC Casing & Cappings - 20x12 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m

WP0200

Coefficient for per m of WP0200

Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4944 PVC Casing & Cappings - 20x12 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m

WP0205

Coefficient for per m of WP0205

Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4945 PVC Casing & Cappings - 25x10 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 2x6 sq.mm

Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 2x2 sq.mm

Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 2x2.5 sq.mm

Wiring for power circuit with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm

Page 24: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 25

Department of Engineering Services, MoWHS

WP0206

Coefficient for per m of WP0206

Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4945 PVC Casing & Cappings - 25x10 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m

WP0207

Coefficient for per m of WP0207

Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m MT4873 PVC sleev 25mm 6.7 each MT4945 PVC Casing & Cappings - 25x10 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m

WP0208

Coefficient for per m of WP0208

Code Description Quant Units LB0051 Mason Gd.2 0.0242 day LB0056 Wireman Gd.1 0.0534 day LB0067 Painter Gd.2 0.0266 day LB0069 Wireman Gd.2 0.0776 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m MT4873 PVC sleev 25mm 6.7 each MT4946 PVC Casing & Cappings - 30x10 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m

WP0209

Coefficient for per m of WP0209

Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.067 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 4.04 m MT4873 PVC sleev 25mm 6.7 each MT4948 PVC Casing & Cappings - 50x20 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 2x10 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 2x16 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 4x10 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 4x6 sq.mm

Page 25: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 26

Department of Engineering Services, MoWHS

WP0210

Coefficient for per m of WP0210

Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.067 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4.04 m MT4873 PVC sleev 25mm 6.7 each MT4948 PVC Casing & Cappings - 50x20 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m

CM0001

Coefficient for per m of CM0001

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4071 PVC insulated single core copper conductor, 1.1KVG - 1.5 sq.mm 2.02 m

CM0002

Coefficient for per m of CM0002

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4071 PVC insulated single core copper conductor, 1.1KVG - 1.5 sq.mm 3.03 m

CM0003

Coefficient for per m of CM0003

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated single core copper conductor, 1.1KVG - 1.5 sq.mm 4.04 m

CM0004

Coefficient for per m of CM0004

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated single core copper conductor, 1.1KVG - 1.5 sq.mm 5.05 m

CM0005

Coefficient for per m of CM0005

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated single core copper conductor, 1.1KVG - 1.5 sq.mm 6.06 m

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC casing and capping including connections, painting, testing and commissioning etc. as required - 4x16 sq.mm

CHAPTER 2: TRUNKING CABLE MANAGEMENT-WIRING

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 6x1.5 sq.mm

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 2x1.5 sq.mm

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 3x1.5 sq.mm

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 4x1.5 sq.mm

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 5x1.5 sq.mm

Page 26: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 27

Department of Engineering Services, MoWHS

CM0006

Coefficient for per m of CM0006

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4071 PVC insulated single core copper conductor, 1.1KVG - 1.5 sq.mm 7.07 m

CM0007

Coefficient for per m of CM0007

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4071 PVC insulated single core copper conductor, 1.1KVG - 1.5 sq.mm 8.08 m

CM0008

Coefficient for per m of CM0008

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4073 PVC insulated single core copper conductor, 1.1KVG - 2.5 sq.mm 2.02 m

CM0009

Coefficient for per m of CM0009

Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4073 PVC insulated single core copper conductor, 1.1KVG - 2.5 sq.mm 3.03 m

CM0010

Coefficient for per m of CM0010

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated single core copper conductor, 1.1KVG - 2.5 sq.mm 4.04 m

CM0011

Coefficient for per m of CM0011

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated single core copper conductor, 1.1KVG - 2.5 sq.mm 5.05 m

CM0012

Coefficient for per m of CM0012

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4073 PVC insulated single core copper conductor, 1.1KVG - 2.5 sq.mm 6.06 m

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 7x1.5 sq.mm

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 8x1.5 sq.mm

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 2x2.5 sq.mm

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 3x2.5 sq.mm

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 4x2.5 sq.mm

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 5x2.5 sq.mm

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 6x2.5 sq.mm

Page 27: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 28

Department of Engineering Services, MoWHS

CM0013

Coefficient for per m of CM0013

Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4074 PVC insulated single core copper conductor, 1.1KVG - 4.0 sq.mm 2.02 m

CM0014

Coefficient for per m of CM0014

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4074 PVC insulated single core copper conductor, 1.1KVG - 4.0 sq.mm 3.03 m

CM0015

Coefficient for per m of CM0015

Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.027 day MT4074 PVC insulated single core copper conductor, 1.1KVG - 4.0 sq.mm 4.04 m

CM0016

Coefficient for per m of CM0016

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4074 PVC insulated single core copper conductor, 1.1KVG - 4.0 sq.mm 5.05 m

CM0017

Coefficient for per m of CM0017

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4075 PVC insulated single core copper conductor, 1.1KVG - 6.0 sq.mm 2.02 m

CM0018

Coefficient for per m of CM0018

Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.027 day MT4075 PVC insulated single core copper conductor, 1.1KVG - 6.0 sq.mm 3.03 m

CM0019

Coefficient for per m of CM0019

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4075 PVC insulated single core copper conductor, 1.1KVG - 6.0 sq.mm 4.04 m

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 5x4.0 sq.mm

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 2x6.0 sq.mm

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 3x6.0 sq.mm

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 4x6.0 sq.mm

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 4x4.0 sq.mm

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 3x4.0 sq.mm

Provide & draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC mini- trunking - 2x4.0 sq.mm

Page 28: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 29

Department of Engineering Services, MoWHS

CM0050

Coefficient for per point of CM0050

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor 1.1KVG - 1.5 sq.mm 4.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7000 PVC mini-trunking - 32x12.5 mm 2 m MT7002 Changeable internal/external angle 1 each

MT7003 Changeble flat angle 1 eachMT7001 End caps 0.1 each

MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

CM0051

Coefficient for per point of CM0051

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor 1.1KVG - 1.5 sq.mm 10.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7000 PVC mini-trunking - 32x12.5 mm 5 m MT7002 Changeable internal/external angle 1 each

MT7003 Changeble flat angle 1 eachMT7001 End caps 0.2 each

MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

CM0052

Coefficient for per point of CM0052

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor 1.1KVG - 1.5 sq.mm 17.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7000 PVC mini-trunking - 32x12.5 mm 8.5 m MT7002 Changeable internal/external angle 1 each

MT7003 Changeble flat angle 1 eachMT7001 End caps 0.5 each

MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking including connections, painting, testing and commissioning etc. as required - Long Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking including connections, painting, testing and commissioning etc. as required - Short Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking including connections, painting, testing and commissioning etc. as required - Medium Point

Page 29: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 30

Department of Engineering Services, MoWHS

Coefficient for per point of CM0053

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4073 PVC insulated Single Core Copper conductor 1.1KVG - 2.5 sq.mm 4.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7000 PVC mini-trunking - 32x12.5 mm 2 m MT7002 Changeable internal/external angle 1 each

MT7003 Changeble flat angle 1 eachMT7001 End caps 0.1 eachMT6537 Wire - 2.5 mm dia. bare copper 2.4 m

MT5800 6A switch SP 1-way 1 eachMT5809 3-pin, 6A socket outlet, shuttered 1 each

MT5824 Plate 3-module with frame 1 each

Coefficient for per point of CM0054

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4073 PVC insulated Single Core Copper conductor 1.1KVG - 2.5 sq.mm 10.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7000 PVC mini-trunking - 32x12.5 mm 5 m MT7002 Changeable internal/external angle 1 each

MT7003 Changeble flat angle 1 eachMT7001 End caps 0.2 eachMT6537 Wire - 2.5 mm dia. bare copper 5.4 mMT5809 3-pin, 6A socket outlet, shuttered 1 each

MT5800 6A switch SP 1-way 1 each MT5824 Plate 3-module with frame 1 each

Coefficient for per point of CM0055

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4073 PVC insulated Single Core Copper conductor 1.1KVG - 2.5 sq.mm 17.4 m MT4862 PVC Boxes - 3 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7000 PVC mini-trunking - 32x12.5 mm 8.5 m MT7002 Changeable internal/external angle 1 each

MT7003 Changeble flat angle 1 eachMT7001 End caps 0.5 eachMT6537 Wire - 2.5 mm dia. bare copper 8.9 mMT5809 3-pin, 6A socket outlet, shuttered 1 each

MT5800 6A switch SP 1-way 1 each MT5824 Plate 3-module with frame 1 each

CM0055

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking with providing and fixing 3/5 pin, 6 ampere socket outlet and switchincluding earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

CM0054

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking with providing and fixing 3/5 pin, 6 ampere socket outlet and switchincluding earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

CM0053

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking with providing and fixing 3/5 pin, 6 ampere socket outlet and switchincluding earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

Page 30: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 31

Department of Engineering Services, MoWHS

Coefficient for per point of CM0056

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor 1.1KVG - 4.0 sq.mm 4.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7005 PVC mini-trunking - 32x16 mm 2 m MT7007 Changeable internal/external angle 1 each

MT7008 Changeble flat angle 1 eachMT7006 End caps 0.1 eachMT6537 Wire - 2.5 mm dia. bare copper 2.4 mMT5814 5/6 pin, 6/16 A socket outlet, shuttered 1 each

MT5800 6A switch SP 1-way 1 each MT5825 Plate 4-module with frame 1 each

Coefficient for per point of CM0057

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor 1.1KVG - 4.0 sq.mm 10.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7005 PVC mini-trunking - 32x16 mm 5 m MT7007 Changeaable internal/external angle 1 each

MT7008 Changeble flat angle 1 eachMT7006 End caps 0.2 eachMT6537 Wire - 2.5 mm dia. bare copper 5.4 mMT5814 5/6 pin, 6/16 A socket outlet, shuttered 1 each

MT5800 6A switch SP 1-way 1 each MT5825 Plate 4-module with frame 1 each

Coefficient for per point of CM0058

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor 1.1KVG - 4.0 sq.mm 17.4 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT7005 PVC mini-trunking - 32x16 mm 8.5 m MT7007 Changeable internal/external angle 1 each

MT7008 Changeble flat angle 1 eachMT7006 End caps 0.5 eachMT6537 Wire - 2.5 mm dia. bare copper 8.9 mMT5814 5/6 pin, 6/16 A socket outlet, shuttered 1 each

MT5800 6A switch SP 1-way 1 each MT5825 Plate 4-module with frame 1 each

CM0056

Wiring for 5/6 pin, 6/16 ampere plug point with 4.0 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switchincluding earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

CM0057

Wiring for 5/6 pin, 6/16 ampere plug point with 4.0 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switchincluding earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

CM0058

Wiring for 5/6 pin, 6/16 ampere plug point with 4.0 sq.mm 1.1KV grade, PVC insulated copper conductor cable in PVC mini-trunking with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switchincluding earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

Page 31: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 32

Department of Engineering Services, MoWHS

Coefficient for per m of CM0090

Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4071 PVC insulated Single Core Copper conductor 1.1KVG - 1.5 sq.mm 2.02 m MT7000 PVC mini-trunking - 32x12.5 mm 1 m MT7002 Changeable internal angle 0.3 each

MT7002 Changeable external angle 0.21 eachMT7003 Changeable flat angle 0.32 eachMT7001 End caps 0.03 each

Coefficient for per m of CM0091

Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4074 PVC insulated Single Core Copper conductor 1.1KVG - 4.0 sq.mm 2.02 m MT7005 PVC mini-trunking - 32x16 mm 1 m MT7002 Changeable internal angle 0.3 each

MT7002 Changeable external angle 0.21 eachMT7003 Changeable flat angle 0.32 eachMT7001 End caps 0.03 each

CM0100

Coefficient for per m of CM0100

Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4073 PVC insulated Single Core Copper conductor 1.1KVG - 2.5 sq.mm 2.02 m

MT7005 PVC mini-trunking - 32x16 mm 1 mMT7002 Changeable internal angle 0.3 eachMT7002 Changeable external angle 0.21 eachMT7003 Changeable flat angle 0.32 eachMT7001 End caps 0.03 each

CM0101

Coefficient for per m of CM0101

Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4074 PVC insulated Single Core Copper conductor 1.1KVG - 4.0 sq.mm 2.02 m

MT7005 PVC mini-trunking - 32x16 mm 1 mMT7002 Changeable internal angle 0.3 eachMT7002 Changeable external angle 0.21 eachMT7003 Changeable flat angle 0.32 eachMT7001 End caps 0.03 each

CM0090Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in PVC mini-trunking including connections, painting, testing and commissioning etc. asrequired - 2x1.5 sq.mm

CM0091Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in PVC mini-trunking including connections, painting, testing and commissioning etc. asrequired - 2x4.0 sq.mm

Wiring for lighting circuit with 1.1KV grade, PVC insulated copper conductor cable in PVC mini- trunking including connections, painting, testing and commissioning etc. as required - 2x2.5 sq.mm

Wiring for power circuit with 1.1KV grade, PVC insulated copper conductor cable in PVC mini- trunking including connections, painting, testing and commissioning etc. as required - 2x4.0 sq.mm

Page 32: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 33

Department of Engineering Services, MoWHS

WM0001

Coefficient for per m of WM0001

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.02 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 1.01 m

WM0002

Coefficient for per m of WM0002

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.02 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 2.02 m

WM0003

Coefficient for per m of WM0003

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.02 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 3.03 m

WM0004

Coefficient for per m of WM0004

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.0062 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 4.04 m

WM0005

Coefficient for per m of WM0005

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.0062 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 5.05 m

WM0006

Coefficient for per m of WM0006

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.0062 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 6.06 m

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 1x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 2x1.5 sq.mm

CHAPTER 3: MS CONDUIT WIRING

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 4x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 3x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 5x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 6x1.5 sq.mm

Page 33: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 34

Department of Engineering Services, MoWHS

WM0007

Coefficient for per m of WM0007

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.0076 day LB0069 Wireman Gd.2 0.03 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 7.07 m

WM0008

Coefficient for per m of WM0008

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.0076 day LB0069 Wireman Gd.2 0.03 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 8.08 m

WM0009

Coefficient for per m of WM0009

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.02 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 2.02 m

WM0010

Coefficient for per m of WM0010

Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.023 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 3.03 m

WM0011

Coefficient for per m of WM0011

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.0062 day LB0069 Wireman Gd.2 0.025 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 4.04 m

WM0012

Coefficient for per m of WM0012

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.0062 day LB0069 Wireman Gd.2 0.025 day MT4021 PVC insulated & sheathed single core Aluminium conductor, 440V G - 2.5 sq.m 5.05 m

WM0013

Coefficient for per m of WM0013

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0067 Painter Gd.2 0.0076 day LB0069 Wireman Gd.2 0.028 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 6.06 m

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 4x2.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 3x2.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 2x2.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 6x2.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 7x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 8x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 5x2.5 sq.mm

Page 34: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 35

Department of Engineering Services, MoWHS

WM0014

Coefficient for per m of WM0014

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.02 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 2.02 m

WM0015

Coefficient for per m of WM0015

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.0062 day LB0069 Wireman Gd.2 0.025 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 3.03 m

WM0016

Coefficient for per m of WM0016

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.0076 day LB0069 Wireman Gd.2 0.03 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 4.04 m

WM0017

Coefficient for per m of WM0017

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.0076 day LB0069 Wireman Gd.2 0.03 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 5.05 m

WM0018

Coefficient for per m of WM0018

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.02 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 2.02 m

WM0019

Coefficient for per m of WM0019

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.0076 day LB0069 Wireman Gd.2 0.03 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 3.0302 m

WM0020

Coefficient for per m of WM0020

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.0076 day LB0069 Wireman Gd.2 0.03 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 4.04 m

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 2x4 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 3x4 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 4x6 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 4x4 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 5x4 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 2x6 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing MS surface conduit - 3x6 sq.mm

Page 35: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 36

Department of Engineering Services, MoWHS

WM0040

Coefficient for per m of WM0040

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 1.01 m

WM0041

Coefficient for per m of WM0041

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m

WM0042

Coefficient for per m of WM0042

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 3.03 m

WM0043

Coefficient for per m of WM0043

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.04 m

WM0044

Coefficient for per m of WM0044

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 5.05 m

WM0045

Coefficient for per m of WM0045

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.06 m

WM0046

Coefficient for per m of WM0046

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 7.07 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 1x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 2x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 3x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 4x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 5x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 6x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 7x1 sq.mm

Page 36: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 37

Department of Engineering Services, MoWHS

WM0047

Coefficient for per m of WM0047

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 8.08 m

WM0048

Coefficient for per m of WM0048

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 9.09 m

WM0049

Coefficient for per m of WM0049

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m

WM0050

Coefficient for per m of WM0050

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 3.03 m

WM0051

Coefficient for per m of WM0051

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.04 m

WM0052

Coefficient for per m of WM0052

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 5.05 m

WM0053

Coefficient for per m of WM0053

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.06 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 8x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 9x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 2x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 3x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 4x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 5x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 6x1.5 sq.mm

Page 37: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 38

Department of Engineering Services, MoWHS

WM0054

Coefficient for per m of WM0054

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 7.07 m

WM0055

Coefficient for per m of WM0055

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 8.08 m

WM0056

Coefficient for per m of WM0056

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m

WM0057

Coefficient for per m of WM0057

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 3.03 m

WM0058

Coefficient for per m of WM0058

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.04 m

WM0059

Coefficient for per m of WM0059

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 5.05 m

WM0060

Coefficient for per m of WM0060

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 6.06 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 8x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 2x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 3x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 4x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 7x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 5x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 6x2 sq.mm

Page 38: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 39

Department of Engineering Services, MoWHS

WM0061

Coefficient for per m of WM0061

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m

WM0062

Coefficient for per m of WM0062

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 3.03 m

WM0063

Coefficient for per m of WM0063

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.04 m

WM0064

Coefficient for per m of WM0064

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 5.05 m

WM0065

Coefficient for per m of WM0065

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 6.06 m

WM0066

Coefficient for per m of WM0066

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 2x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 3x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 4x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 5x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 6x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 2x4 sq.mm

Page 39: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 40

Department of Engineering Services, MoWHS

WM0067

Coefficient for per m of WM0067

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 3.03 m

WM0068

Coefficient for per m of WM0068

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.04 m

WM0069

Coefficient for per m of WM0069

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 5.05 m

WM0070

Coefficient for per m of WM0070

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.025 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m

WM0071

Coefficient for per m of WM0071

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 3.0302 m

WM0072

Coefficient for per m of WM0072

Code Description Quant Units LB0056 Wireman Gd.1 0.0338 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.0338 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 3x4 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 4x4 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 5x4 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 2x6 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 3x6 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing MS surface conduit - 4x6 sq.mm

Page 40: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 41

Department of Engineering Services, MoWHS

WM0095

Coefficient for per point of WM0095

Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

WM0096

Coefficient for per point of WM0096

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

WM0097

Coefficient for per point of WM0097

Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 1 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - Short Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - Medium Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - Long Point

Page 41: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 42

Department of Engineering Services, MoWHS

WM0105

Coefficient for per point of WM0105

Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

WM0106

Coefficient for per point of WM0106

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

WM0107

Coefficient for per point of WM0107

Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 1 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - Medium Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - Short Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - Long Point

Page 42: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 43

Department of Engineering Services, MoWHS

WM0115

Coefficient for per point of WM0115

Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each

WM0116

Coefficient for per point of WM0116

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each

WM0117

Coefficient for per point of WM0117

Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 1 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and comissioning etc. as required- Short Point

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required -Long Point

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

Page 43: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 44

Department of Engineering Services, MoWHS

Coefficient for per point of WM0125

Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WM0126

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WM0127

Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 1 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each

WM0126

WM0125

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

WM0127

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch

Page 44: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 45

Department of Engineering Services, MoWHS

Coefficient for per point of WM0135

Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4809 M.S Coduit - M.S Saddle 4 each MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WM0136

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WM0137

Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 1 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m

switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch

WM0135

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

WM0137

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switchincluding earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WM0136

Page 45: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 46

Department of Engineering Services, MoWHS

MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WM0145

Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4809 M.S Coduit - M.S Saddle 4 each MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WM0146

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WM0147

Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

WM0145

WM0147

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WM0146

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch

Page 46: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 47

Department of Engineering Services, MoWHS

LB0069 Wireman Gd.2 1 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WM0155

Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WM0156

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

WM0155

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WM0156

Page 47: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 48

Department of Engineering Services, MoWHS

Coefficient for per point of WM0157

Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 1 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WM0165

Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WM0166

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point WM0157

Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Short Point

WM0165

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including

Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WM0166

Page 48: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 49

Department of Engineering Services, MoWHS

Coefficient for per point of WM0167

Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 1 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m

MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WM0175

Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WM0176

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.625 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

and commissioning etc. as required - Long Point WM0167

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Short Point

WM0175

Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Medium Point

WM0176

Page 49: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 50

Department of Engineering Services, MoWHS

Coefficient for per point of WM0177

Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 1 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per m of WM0185

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.064 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0824 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each

Coefficient for per m of WM0186

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.064 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0824 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each

etc. as required - Long Point WM0177

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 2x1 sq.mm

WM0185

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 2x1.5 sq.mm

WM0186

Page 50: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 51

Department of Engineering Services, MoWHS

Coefficient for per m of WM0187

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.0704 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0906 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each

WM0195

Coefficient for per m of WM0195

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.064 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0824 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each

WM0196

Coefficient for per m of WM0196

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.064 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0824 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each

WM0205

Coefficient for per m of WM0205

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.0704 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0906 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m

required - 2x4 sq.mm WM0187

Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 2x2 sq.mm

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as

Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 2x2.5 sq.mm

Wiring for power circuit with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting,testing and commissioning etc. as required - 2x4 sq.mm

Page 51: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 52

Department of Engineering Services, MoWHS

MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each

WM0210

Coefficient for per m of WM0210

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.0704 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0906 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m MT4802 M.S Coduit - 25mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each

WM0211

Coefficient for per m of WM0211

Code Description Quant Units LB0051 Mason Gd.2 0.0286 day LB0056 Wireman Gd.1 0.0754 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.097 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m MT4803 M.S Coduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each

WM0212

Coefficient for per m of WM0212

Code Description Quant Units LB0051 Mason Gd.2 0.0286 day LB0056 Wireman Gd.1 0.0754 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.097 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m MT4803 M.S Coduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each

WM0213

Coefficient for per m of WM0213

Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.0874 day

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 2x6 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 2x10 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 2x16 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 4x6 sq.mm

Page 52: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 53

Department of Engineering Services, MoWHS

LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.01108 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m MT4803 M.S Coduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each

WM0214

Coefficient for per m of WM0214

Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.0874 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.01108 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 4.04 m MT4804 M.S Coduit - 40mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each

WM0215

Coefficient for per m of WM0215

Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.0874 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.01108 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4.04 m MT4805 M.S Coduit - 50mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4.08 each

Coefficient for per point of WM0230

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 4x10 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in surface MS conduit including connections, painting, testing and commissioning etc. as required - 4x16 sq.mm

commissioning etc. as required - Short Point WM0230

Page 53: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 54

Department of Engineering Services, MoWHS

Coefficient for per point of WM0231

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WM0232

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WM0240

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - Long Point

WM0232

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - Medium Point

WM0231

commissioning etc. as required - Short Point WM0240

Page 54: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 55

Department of Engineering Services, MoWHS

Coefficient for per point of WM0241

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WM0242

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal Boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WM0250

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - Long Point

WM0242

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - Medium Point

WM0241

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

WM0250

Page 55: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 56

Department of Engineering Services, MoWHS

MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WM0251

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WM0252

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WM0260

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

WM0260

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WM0251

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

WM0252

Page 56: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 57

Department of Engineering Services, MoWHS

MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WM0261

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WM0262

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal Boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WM0270

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

WM0270

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

WM0262

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WM0261

Page 57: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 58

Department of Engineering Services, MoWHS

MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4809 M.S Coduit - M.S Saddle 4 each MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WM0271

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WM0272

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WM0271

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

WM0272

Page 58: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 59

Department of Engineering Services, MoWHS

Coefficient for per point of WM0280

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4809 M.S Coduit - M.S Saddle 4 each MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WM0281

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WM0282

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch

WM0280

WM0281

WM0282

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

Page 59: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 60

Department of Engineering Services, MoWHS

Coefficient for per point of WM0290

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WM0291

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WM0292

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal Boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3 pin, 16 ampere socket outlet and

switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3 pin, 16 ampere socket outlet and

WM0290

WM0291

WM0292

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

Page 60: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 61

Department of Engineering Services, MoWHS

Coefficient for per point of WM0300

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WM0301

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WM0302

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Short Point

WM0300

Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WM0301

Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Long Point

WM0302

Page 61: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 62

Department of Engineering Services, MoWHS

Coefficient for per point of WM0310

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m MT4801 M.S Coduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WM0311

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m MT4801 M.S Coduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Short Point

WM0310

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Medium Point

WM0311

Page 62: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 63

Department of Engineering Services, MoWHS

Coefficient for per point of WM0312

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0067 Painter Gd.2 0.0052 day LB0069 Wireman Gd.2 1.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m MT4801 M.S Coduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per m of WM0320

Code Description Quant Units LB0051 Mason Gd.2 0.08 day LB0056 Wireman Gd.1 0.064 day LB0069 Wireman Gd.2 0.144 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each

Coefficient for per m of WM0321

Code Description Quant Units LB0051 Mason Gd.2 0.08 day LB0056 Wireman Gd.1 0.064 day LB0069 Wireman Gd.2 0.144 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each

Coefficient for per m of WM0322

Code Description Quant Units LB0051 Mason Gd.2 0.088 day LB0056 Wireman Gd.1 0.0704 day LB0069 Wireman Gd.2 0.1584 day

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning as required - 2x1 sq.mm

WM0320

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Long Point

WM0312

required - 2x1.5 sq.mm WM0321

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning as required - 2x4 sq.mm

WM0322

Page 63: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 64

Department of Engineering Services, MoWHS

MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each

WM0330

Coefficient for per m of WM0330

Code Description Quant Units LB0051 Mason Gd.2 0.08 day LB0056 Wireman Gd.1 0.064 day LB0069 Wireman Gd.2 0.144 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each

WM0331

Coefficient for per m of WM0331

Code Description Quant Units LB0051 Mason Gd.2 0.08 day LB0056 Wireman Gd.1 0.064 day LB0069 Wireman Gd.2 0.144 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each

WM0340

Coefficient for per m of WM0340

Code Description Quant Units LB0051 Mason Gd.2 0.088 day LB0056 Wireman Gd.1 0.0704 day LB0069 Wireman Gd.2 0.1584 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each

WM0350

Coefficient for per m of WM0350

Code Description Quant Units LB0051 Mason Gd.2 0.088 day LB0056 Wireman Gd.1 0.0704 day LB0069 Wireman Gd.2 0.1584 day

Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - 2x2 sq.mm

Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - 2x2.5 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required- 2x6 sq.mm

Wiring for power circuit with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm

Page 64: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 65

Department of Engineering Services, MoWHS

MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m MT4802 M.S Coduit - 25mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each

WM0351

Coefficient for per m of WM0351

Code Description Quant Units LB0051 Mason Gd.2 0.0942 day LB0056 Wireman Gd.1 0.0754 day LB0069 Wireman Gd.2 0.1694 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m MT4803 M.S Coduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each

WM0352

Coefficient for per m of WM0352

Code Description Quant Units LB0051 Mason Gd.2 0.0942 day LB0056 Wireman Gd.1 0.0754 day LB0069 Wireman Gd.2 0.1694 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m MT4803 M.S Coduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each

WM0353

Coefficient for per m of WM0353

Code Description Quant Units LB0051 Mason Gd.2 0.1008 day LB0056 Wireman Gd.1 0.0806 day LB0069 Wireman Gd.2 0.1812 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m MT4803 M.S Coduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required- 2x10 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - 4x6 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required- 2x16 sq.mm

Page 65: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 66

Department of Engineering Services, MoWHS

WM0354

Coefficient for per m of WM0354

Code Description Quant Units LB0051 Mason Gd.2 0.1078 day LB0056 Wireman Gd.1 0.0862 day LB0069 Wireman Gd.2 0.01938 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 4.04 m MT4804 M.S Coduit - 40mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each

WM0355

Coefficient for per m of WM0355

Code Description Quant Units LB0051 Mason Gd.2 0.1078 day LB0056 Wireman Gd.1 0.0862 day LB0069 Wireman Gd.2 0.01938 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4.04 m MT4805 M.S Coduit - 50mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 2.04 each

WC0001

Coefficient for per m of WC0001

Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0069 Wireman Gd.2 0.024 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 1.01 m

WC0002

Coefficient for per m of WC0002

Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0069 Wireman Gd.2 0.024 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 2.02 m

WC0003

Coefficient for per m of WC0003

Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0069 Wireman Gd.2 0.024 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 3.03 m

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - 4x16 sq.mm

CHAPTER 4: PVC CONDUIT WIRING

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 1x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 2x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 3x1.5 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed MS conduit including connections, painting, testing and commissioning etc. as required - 4x10 sq.mm

Page 66: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 67

Department of Engineering Services, MoWHS

WC0004

Coefficient for per m of WC0004

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 4.04 m

WC0005

Coefficient for per m of WC0005

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 5.05 m

WC0006

Coefficient for per m of WC0006

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 6.06 m

WC0007

Coefficient for per m of WC0007

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 7.07 m

WC0008

Coefficient for per m of WC0008

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4001 PVC insulated single core Aluminium conductor, 440V G - 1.5 sq.mm 8.08 m

WC0009

Coefficient for per m of WC0009

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 2.02 m

WC0010

Coefficient for per m of WC0010

Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 3.03 m

WC0011

Coefficient for per m of WC0011

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 4.04 m

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 7x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 5x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 6x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 8x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 2x2.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 4x1.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 3x2.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 4x2.5 sq.mm

Page 67: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 68

Department of Engineering Services, MoWHS

WC0012

Coefficient for per m of WC0012

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 5.05 m

WC0013

Coefficient for per m of WC0013

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4002 PVC insulated single core Aluminium conductor, 440V G - 2.5 sq.mm 6.06 m

WC0014

Coefficient for per m of WC0014

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 2.02 m

WC0015

Coefficient for per m of WC0015

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 3.03 m

WC0016

Coefficient for per m of WC0016

Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.027 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 4.04 m

WC0017

Coefficient for per m of WC0017

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4003 PVC insulated single core Aluminium conductor, 440V G - 4 sq.mm 5.05 m

WC0018

Coefficient for per m of WC0018

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 2.02 m

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 2x4 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 3x4 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 4x4 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 5x4 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 5x2.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 6x2.5 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 2x6 sq.mm

Page 68: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 69

Department of Engineering Services, MoWHS

WC0019

Coefficient for per m of WC0019

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 3.0302 m

WC0020

Coefficient for per m of WC0020

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4004 PVC insulated single core Aluminium conductor, 440V G - 6 sq.mm 4.04 m

WC0040

Coefficient for per m of WC0040

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 1.01 m

WC0041

Coefficient for per m of WC0041

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m

WC0042

Coefficient for per m of WC0042

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 3.03 m

WC0043

Coefficient for per m of WC0043

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.04 m

WC0044

Coefficient for per m of WC0044

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 5.05 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 2x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 3x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 4x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 5x1 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 3x6 sq.mm

Provide & Draw Single Core 440V grade PVC insulated Aluminium conductor cable in existing PVC surface conduit - 4x6 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 1x1 sq.mm

Page 69: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 70

Department of Engineering Services, MoWHS

WC0045

Coefficient for per m of WC0045

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.06 m

WC0046

Coefficient for per m of WC0046

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 7.07 m

WC0047

Coefficient for per m of WC0047

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 8.08 m

WC0048

Coefficient for per m of WC0048

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 9.09 m

WC0049

Coefficient for per m of WC0049

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m

WC0050

Coefficient for per m of WC0050

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 3.03 m

WC0051

Coefficient for per m of WC0051

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.04 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 4x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 6x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 7x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 8x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 9x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 2x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 3x1.5 sq.mm

Page 70: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 71

Department of Engineering Services, MoWHS

WC0052

Coefficient for per m of WC0052

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 5.05 m

WC0053

Coefficient for per m of WC0053

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.06 m

WC0054

Coefficient for per m of WC0054

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 7.07 m

WC0055

Coefficient for per m of WC0055

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 8.08 m

WC0056

Coefficient for per m of WC0056

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m

WC0057

Coefficient for per m of WC0057

Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 3.03 m

WC0058

Coefficient for per m of WC0058

Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0069 Wireman Gd.2 0.024 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.04 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 7x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 6x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 5x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 2x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 3x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 8x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 4x2 sq.mm

Page 71: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 72

Department of Engineering Services, MoWHS

WC0059

Coefficient for per m of WC0059

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 5.05 m

WC0060

Coefficient for per m of WC0060

Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0069 Wireman Gd.2 0.026 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 6.06 m

WC0061

Coefficient for per m of WC0061

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m

WC0062

Coefficient for per m of WC0062

Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 3.03 m

WC0063

Coefficient for per m of WC0063

Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0069 Wireman Gd.2 0.024 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.04 m

WC0064

Coefficient for per m of WC0064

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 5.05 m

WC0065

Coefficient for per m of WC0065

Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0069 Wireman Gd.2 0.026 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 6.06 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 5x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 4x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 5x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 6x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 6x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 2x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 3x2.5 sq.mm

Page 72: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 73

Department of Engineering Services, MoWHS

WC0066

Coefficient for per m of WC0066

Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0069 Wireman Gd.2 0.023 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m

WC0067

Coefficient for per m of WC0067

Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0069 Wireman Gd.2 0.024 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 3.03 m

WC0068

Coefficient for per m of WC0068

Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0069 Wireman Gd.2 0.026 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.04 m

WC0069

Coefficient for per m of WC0069

Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.027 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 5.05 m

WC0070

Coefficient for per m of WC0070

Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0069 Wireman Gd.2 0.024 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m

WC0071

Coefficient for per m of WC0071

Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0069 Wireman Gd.2 0.026 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 3.0302 m

WC0072

Coefficient for per m of WC0072

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 5x4 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 4x4 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 3x4 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 2x6 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 3x6 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 4x6 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC surface conduit - 2x4 sq.mm

Page 73: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 74

Department of Engineering Services, MoWHS

WC0095

Coefficient for per m of WC0095

Code Description Quant Units LB0051 Mason Gd.2 0.01 day LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 1.01 m

WC0096

Coefficient for per m of WC0096

Code Description Quant Units LB0051 Mason Gd.2 0.01 day LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m

WC0097

Coefficient for per m of WC0097

Code Description Quant Units LB0051 Mason Gd.2 0.01 day LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 3.03 m

WC0098

Coefficient for per m of WC0098

Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.04 m

WC0099

Coefficient for per m of WC0099

Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 5.05 m

WC0100

Coefficient for per m of WC0100

Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.06 m

WC0101

Coefficient for per m of WC0101

Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 7.07 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 1x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 2x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 5x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 6x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 7x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 3x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 4x1 sq.mm

Page 74: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 75

Department of Engineering Services, MoWHS

WC0102

Coefficient for per m of WC0102

Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 8.08 m

WC0103

Coefficient for per m of WC0103

Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 9.09 m

WC0104

Coefficient for per m of WC0104

Code Description Quant Units LB0051 Mason Gd.2 0.01 day LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m

WC0105

Coefficient for per m of WC0105

Code Description Quant Units LB0051 Mason Gd.2 0.01 day LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 3.03 m

WC0106

Coefficient for per m of WC0106

Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.04 m

WC0107

Coefficient for per m of WC0107

Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 5.05 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 9x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 2x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 5x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 8x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 3x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 4x1.5 sq.mm

Page 75: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 76

Department of Engineering Services, MoWHS

WC0108

Coefficient for per m of WC0108

Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.06 m

WC0109

Coefficient for per m of WC0109

Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 7.07 m

WC0110

Coefficient for per m of WC0110

Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 8.08 m

WC0111

Coefficient for per m of WC0111

Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m

WC0112

Coefficient for per m of WC0112

Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 3.03 m

WC0113

Coefficient for per m of WC0113

Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.04 m

WC0114

Coefficient for per m of WC0114

Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 5.05 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 6x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 2x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 3x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 4x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 5x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 7x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 8x1.5 sq.mm

Page 76: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 77

Department of Engineering Services, MoWHS

WC0115

Coefficient for per m of WC0115

Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 6.06 m

WC0116

Coefficient for per m of WC0116

Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m

WC0117

Coefficient for per m of WC0117

Code Description Quant Units LB0051 Mason Gd.2 0.012 day LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 3.03 m

WC0118

Coefficient for per m of WC0118

Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.04 m

WC0119

Coefficient for per m of WC0119

Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 5.05 m

WC0120

Coefficient for per m of WC0120

Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 6.06 m

WC0121

Coefficient for per m of WC0121

Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 2x4 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 4x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 5x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 3x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 6x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 2x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 6x2.5 sq.mm

Page 77: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 78

Department of Engineering Services, MoWHS

WC0122

Coefficient for per m of WC0122

Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.044 day LB0069 Wireman Gd.2 0.044 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 3.03 m

WC0123

Coefficient for per m of WC0123

Code Description Quant Units LB0051 Mason Gd.2 0.016 day LB0056 Wireman Gd.1 0.046 day LB0069 Wireman Gd.2 0.046 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.04 m

WC0124

Coefficient for per m of WC0124

Code Description Quant Units LB0051 Mason Gd.2 0.016 day LB0056 Wireman Gd.1 0.048 day LB0069 Wireman Gd.2 0.048 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 5.05 m

WC0125

Coefficient for per m of WC0125

Code Description Quant Units LB0051 Mason Gd.2 0.014 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m

WC0126

Coefficient for per m of WC0126

Code Description Quant Units LB0051 Mason Gd.2 0.016 day LB0056 Wireman Gd.1 0.044 day LB0069 Wireman Gd.2 0.044 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 3.0302 m

WC0127

Coefficient for per m of WC0127

Code Description Quant Units LB0051 Mason Gd.2 0.016 day LB0056 Wireman Gd.1 0.048 day LB0069 Wireman Gd.2 0.048 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 3x6 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 4x6 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 3x4 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 4x4 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 5x4 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing PVC concealed conduit - 2x6 sq.mm

Page 78: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 79

Department of Engineering Services, MoWHS

WC0150

Coefficient for per point of WC0150

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

WC0151

Coefficient for per point of WC0151

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

WC0152

Coefficient for per point of WC0152

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m MT4840 PVC Conduit - 20 mm,18SWG 6.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - Long Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - Medium Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - Short Point

Page 79: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 80

Department of Engineering Services, MoWHS

WC0160

Coefficient for per point of WC0160

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

WC0161

Coefficient for per point of WC0161

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

WC0162

Coefficient for per point of WC0162

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m MT4840 PVC Conduit - 20 mm,18SWG 6.4 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - Short Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - Long Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - Medium Point

Page 80: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 81

Department of Engineering Services, MoWHS

Coefficient for per point of WC0170

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4862 PVC Boxes - 3 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WC0171

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT4862 PVC Boxes - 3 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WC0172

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4840 PVC Conduit - 20 mm,18SWG 6.4 m MT4862 PVC Boxes - 3 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each

earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including

earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including

WC0171

WC0172

WC0170

earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

Page 81: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 82

Department of Engineering Services, MoWHS

Coefficient for per point of WC0180

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4862 PVC Boxes - 3 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WC0181

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT4862 PVC Boxes - 3 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WC0182

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4840 PVC Conduit - 20 mm,18SWG 6.4 m MT4862 PVC Boxes - 3 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each

WC0181

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including

earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WC0182

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

WC0180

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including

earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

Page 82: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 83

Department of Engineering Services, MoWHS

MT5800 6A switch SP 1-way 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WC0190

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4863 PVC Boxes - 4 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0191

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT4863 PVC Boxes - 4 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0192

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4840 PVC Conduit - 20 mm,18SWG 6.4 m MT4863 PVC Boxes - 4 Module 1 each

earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including WC0190

WC0191

earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including WC0192

Page 83: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 84

Department of Engineering Services, MoWHS

MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0200

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4863 PVC Boxes - 4 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0201

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT4863 PVC Boxes - 4 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0202

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m

earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point WC0200

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including WC0201

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

WC0202

Page 84: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 85

Department of Engineering Services, MoWHS

MT4809 M.S Coduit - M.S Saddle 15 each MT4840 PVC Conduit - 20 mm,18SWG 6.4 m MT4863 PVC Boxes - 4 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0210

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4863 PVC Boxes - 4 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0211

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT4863 PVC Boxes - 4 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0212

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day

earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point WC0210

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including

earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point WC0211

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

WC0212

Page 85: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 86

Department of Engineering Services, MoWHS

LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4840 PVC Conduit - 20 mm,18SWG 6.4 m MT4863 PVC Boxes - 4 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0220

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4860 PVC Boxes - 1 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WC0221

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m MT4809 M.S Coduit - M.S Saddle 9 each MT4860 PVC Boxes - 1 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WC0222

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day

Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with 2 way 6 ampere switch including earthing third pin, connections, painting,testing and commissioning etc. as required - Short Point

WC0220

Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WC0221

Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Long Point

WC0222

Page 86: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 87

Department of Engineering Services, MoWHS

MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m MT4809 M.S Coduit - M.S Saddle 15 each MT4860 PVC Boxes - 1 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT4840 PVC Conduit - 20 mm,18SWG 6.4 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WC0230

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 1.5 m MT4860 PVC Boxes - 1 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WC0231

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m MT4809 M.S Coduit - M.S Saddle 9 each MT4840 PVC Conduit - 20 mm,18SWG 3.75 m MT4860 PVC Boxes - 1 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WC0232

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m MT4809 M.S Coduit - M.S Saddle 15 each MT4840 PVC Conduit - 20 mm,18SWG 6.4 m

commissioning etc. as required - Short Point WC0230

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with 2 way 6 ampere switch including connections, painting, testing andcommissioning etc. as required - Medium Point

WC0231

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with 2 way 6 ampere switch including connections, painting, testing and

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Long Point

WC0232

Page 87: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 88

Department of Engineering Services, MoWHS

MT4860 PVC Boxes - 1 Module 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per m of WC0240

Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m MT4840 PVC Conduit - 20 mm,18SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each

Coefficient for per m of WC0241

Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m MT4840 PVC Conduit - 20 mm,18SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each

Coefficient for per m of WC0242

Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4840 PVC Conduit - 20 mm,18SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each

Coefficient for per m of WC0250

Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m MT4840 PVC Conduit - 20 mm,18SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each

required - 2x1 sq.mm WC0240

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as

Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required- 2x2 sq.mm

WC0250

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 2x1.5 sq.mm

WC0241

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm

WC0242

Page 88: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 89

Department of Engineering Services, MoWHS

WC0251

Coefficient for per m of WC0251

Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m MT4840 PVC Conduit - 20 mm,18SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each

WC0260

Coefficient for per m of WC0260

Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4840 PVC Conduit - 20 mm,18SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each

WC0270

Coefficient for per m of WC0270

Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m MT4841 PVC Conduit - 25 mm,16SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each

WC0271

Coefficient for per m of WC0271

Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m MT4842 PVC Conduit - 32 mm,14SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each

Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 2x2.5 sq.mm

Wiring for power circuit with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 2x6 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 2x10 sq.mm

Page 89: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 90

Department of Engineering Services, MoWHS

WC0272

Coefficient for per m of WC0272

Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m MT4842 PVC Conduit - 32 mm,14SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each

WC0273

Coefficient for per m of WC0273

Code Description Quant Units LB0051 Mason Gd.2 0.0242 day LB0056 Wireman Gd.1 0.0534 day LB0067 Painter Gd.2 0.0266 day LB0069 Wireman Gd.2 0.0776 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m MT4842 PVC Conduit - 32 mm,14SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each

WC0274

Coefficient for per m of WC0274

Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.067 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 4.04 m MT4843 PVC Conduit - 40 mm,14SWG 1 m MT4872 Inspection bend for conduit 0.2 each MT4874 PVC sleev 35mm 4.08 each

WC0275

Coefficient for per m of WC0275

Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.067 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4.04 m MT4844 PVC Conduit - 50 mm,14SWG 1 m MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4.08 each

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 4x16 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 2x16 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 4x6 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in PVC surface conduit including connections, painting, testing and commissioning etc. as required - 4x10 sq.mm

Page 90: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 91

Department of Engineering Services, MoWHS

Coefficient for per point of WC0290

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe - 20mm 1.5 m MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WC0291

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4850 HDPE pipe - 20mm 3.75 m MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WC0292

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4850 HDPE pipe - 20mm 6.4 m MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - Long Point

WC0291

WC0292

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - Medium Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - Short Point

WC0290

Page 91: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 92

Department of Engineering Services, MoWHS

Coefficient for per point of WC0300

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe - 20mm 1.5 m MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WC0301

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4850 HDPE pipe - 20mm 3.75 m MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WC0302

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4850 HDPE pipe - 20mm 6.4 m MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

commissioning etc. as required - Long Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and

commissioning etc. as required - Short Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - Medium Point

WC0301

WC0302

WC0300

Page 92: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 93

Department of Engineering Services, MoWHS

Coefficient for per point of WC0310

Code Description Quant Units LB0051 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe - 20mm 1.5 m

MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 2 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WC0311

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each mt4850 HDPE pipe - 20mm 3.75 m MT4870 PVC Socket 2 each

MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WC0312

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4850 HDPE pipe - 20mm 6.4 m MT4870 PVC Socket 3 each

MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each

earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including

earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including

WC0311

WC0312

WC0310

Page 93: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 94

Department of Engineering Services, MoWHS

MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WC0320

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe - 20mm 1.5 m

MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WC0321

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4850 HDPE pipe - 20mm 3.75 m MT4870 PVC Socket 2 each

MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WC0322

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4850 HDPE pipe - 20mm 6.4 m MT4870 PVC Socket 3 each

MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3/5 pin, 6 ampere socket outlet and switch

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

WC0321

WC0322

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3/5 pin, 6 ampere socket outlet and switch

WC0320

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

Page 94: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 95

Department of Engineering Services, MoWHS

MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WC0330

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe -20mm 1.5 m

MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0331

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4850 HDPE pipe - 20mm 3.75 m MT4870 PVC Socket 2 each

MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0332

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4850 HDPE pipe - 20mm 6.4 m MT4870 PVC Socket 3 each

MT4871 Junction box, 1 or 2 way for conduit 1 each

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3 pin, 6/16 ampere socket outlet and switch

WC0331

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

WC0332

WC0330

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3 pin, 6/16 ampere socket outlet and switch

Page 95: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 96

Department of Engineering Services, MoWHS

MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0340

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe - 20mm 1.5 m

MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0341

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4850 HDPE pipe - 20mm 3.75 m MT4870 PVC Socket 2 each

MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0342

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4809 M.S Coduit - M.S Saddle 15 each MT4850 HDPE pipe - 20mm 6.4 m

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

WC0342

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

WC0340

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WC0341

Page 96: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 97

Department of Engineering Services, MoWHS

MT4870 PVC Socket 3 eachMT4871 Junction box, 1 or 2 way for conduit 1 each

MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0350

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe - 20mm 1.5 m

MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0351

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4809 M.S Coduit - M.S Saddle 9 each MT4850 HDPE pipe - 20mm 3.75 m MT4870 PVC Socket 2 each

MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0352

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WC0351

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

WC0352

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

WC0350

Page 97: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 98

Department of Engineering Services, MoWHS

MT4809 M.S Coduit - M.S Saddle 15 each MT4850 HDPE pipe - 20mm 6.4 m MT4870 PVC Socket 3 each

MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WC0360

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe - 20mm 1.5 m MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WC0361

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m MT4809 M.S Coduit - M.S Saddle 9 each MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT4850 HDPE pipe - 20mm 3.75 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WC0362

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m

Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Short Point

WC0360

Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WC0361

Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Long Point

WC0362

Page 98: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 99

Department of Engineering Services, MoWHS

MT4809 M.S Coduit - M.S Saddle 15 each MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT4850 HDPE pipe - 20mm 6.4 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WC0370

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m MT4809 M.S Coduit - M.S Saddle 4 each MT4850 HDPE pipe - 20mm 1.5 m MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WC0371

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m MT4809 M.S Coduit - M.S Saddle 9 each MT4850 HDPE pipe - 20mm 3.75 m MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WC0372

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 1.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m MT4809 M.S Coduit - M.S Saddle 15 each

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Short Point

WC0370

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Medium Point

WC0371

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Long Point

WC0372

Page 99: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 100

Department of Engineering Services, MoWHS

MT4850 HDPE pipe - 20mm 6.4 m MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per m of WC0380

Code Description Quant Units LB0051 Mason Gd.2 0.0784 day LB0056 Wireman Gd.1 0.0628 day LB0069 Wireman Gd.2 0.1412 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4850 HDPE pipe - 20mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each

Coefficient for per m of WC0381

Code Description Quant Units LB0051 Mason Gd.2 0.0784 day LB0056 Wireman Gd.1 0.0628 day LB0069 Wireman Gd.2 0.1412 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4850 HDPE pipe - 20mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each

Coefficient for per m of WC0382

Code Description Quant Units LB0051 Mason Gd.2 0.0864 day LB0056 Wireman Gd.1 0.069 day LB0069 Wireman Gd.2 0.1552 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4850 HDPE pipe - 20mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x1 sq.mm

WC0380

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x1.5 sq.mm

WC0381

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm

WC0382

Page 100: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 101

Department of Engineering Services, MoWHS

WC0390

Coefficient for per m of WC0390

Code Description Quant Units LB0051 Mason Gd.2 0.0784 day LB0056 Wireman Gd.1 0.0628 day LB0069 Wireman Gd.2 0.1412 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4850 HDPE pipe - 20mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each

WC0391

Coefficient for per m of WC0391

Code Description Quant Units LB0051 Mason Gd.2 0.0784 day LB0056 Wireman Gd.1 0.0628 day LB0069 Wireman Gd.2 0.1412 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4850 HDPE pipe - 20mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each

WC0400

Coefficient for per m of WC0400

Code Description Quant Units LB0051 Mason Gd.2 0.0864 day LB0056 Wireman Gd.1 0.069 day LB0069 Wireman Gd.2 0.1552 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4850 HDPE pipe - 20mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each

WC0410

Coefficient for per m of WC0410

Code Description Quant Units LB0051 Mason Gd.2 0.0864 day LB0056 Wireman Gd.1 0.069 day LB0069 Wireman Gd.2 0.1552 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4851 HDPE pipe - 25mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each

Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x2 sq.mm

Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x2.5 sq.mm

Wiring for power circuit with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x6 sq.mm

Page 101: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 102

Department of Engineering Services, MoWHS

WC0411

Coefficient for per m of WC0411

Code Description Quant Units LB0051 Mason Gd.2 0.0924 day LB0056 Wireman Gd.1 0.074 day LB0069 Wireman Gd.2 0.166 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4852 HDPE pipe - 32mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each

WC0412

Coefficient for per m of WC0412

Code Description Quant Units LB0051 Mason Gd.2 0.0924 day LB0056 Wireman Gd.1 0.074 day LB0069 Wireman Gd.2 0.166 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4852 HDPE pipe - 32 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each

WC0413

Coefficient for per m of WC0413

Code Description Quant Units LB0051 Mason Gd.2 0.0988 day LB0056 Wireman Gd.1 0.079 day LB0069 Wireman Gd.2 0.1776 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4852 HDPE pipe - 32mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each

WC0414

Coefficient for per m of WC0414

Code Description Quant Units LB0051 Mason Gd.2 0.1058 day LB0056 Wireman Gd.1 0.0844 day LB0069 Wireman Gd.2 0.19 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 4.04 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4853 HDPE pipe - 40mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.2 each MT4874 PVC sleev 35mm 4 each

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x10 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 2x16 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 4x6 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 4x10 sq.mm

Page 102: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 103

Department of Engineering Services, MoWHS

WC0415

Coefficient for per m of WC0415

Code Description Quant Units LB0051 Mason Gd.2 0.1058 day LB0056 Wireman Gd.1 0.0844 day LB0069 Wireman Gd.2 0.19 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4.04 m MT4809 M.S Coduit - M.S Saddle 1.02 each MT4854 HDPE pipe - 50mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 4 each

CHAPTER 5: STAINLESS STEEL CONDUIT WIRING

WS0001

Coefficient for per m of WS0001

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 1.01 m

WS0002

Coefficient for per m of WS0002

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m

WS0003

Coefficient for per m of WS0003

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 3.03 m

WS0004

Coefficient for per m of WS0004

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.04 m

WS0005

Coefficient for per m of WS0005

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 5.05 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 2x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 3x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 4x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 1x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 5x1 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in recessed HDPE pipe including connections, painting, testing and commissioning etc. as required - 4x16 sq.mm

Page 103: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 104

Department of Engineering Services, MoWHS

WS0006

Coefficient for per m of WS0006

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.06 m

WS0007

Coefficient for per m of WS0007

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 7.07 m

WS0008

Coefficient for per m of WS0008

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 8.08 m

WS0009

Coefficient for per m of WS0009

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 9.09 m

WS0010

Coefficient for per m of WS0010

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m

WS0011

Coefficient for per m of WS0011

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 3.03 m

WS0012

Coefficient for per m of WS0012

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.04 m

WS0013

Coefficient for per m of WS0013

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 5.05 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 9x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 8x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 7x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 2x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 6x1 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 3x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 4x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 5x1.5 sq.mm

Page 104: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 105

Department of Engineering Services, MoWHS

WS0014

Coefficient for per m of WS0014

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.06 m

WS0015

Coefficient for per m of WS0015

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 7.07 m

WS0016

Coefficient for per m of WS0016

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 8.08 m

WS0017

Coefficient for per m of WS0017

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m

WS0018

Coefficient for per m of WS0018

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 3.03 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 6x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 7x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 8x1.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 2x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 3x2 sq.mm

Page 105: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 106

Department of Engineering Services, MoWHS

WS0019

Coefficient for per m of WS0019

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.04 m

WS0020

Coefficient for per m of WS0020

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 5.05 m

WS0021

Coefficient for per m of WS0021

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 6.06 m

WS0022

Coefficient for per m of WS0022

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m

WS0023

Coefficient for per m of WS0023

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 3.03 m

WS0024

Coefficient for per m of WS0024

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.04 m

WS0025

Coefficient for per m of WS0025

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 5.05 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 5x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 4x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 5x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 6x2 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 2x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 3x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 4x2.5 sq.mm

Page 106: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 107

Department of Engineering Services, MoWHS

WS0026

Coefficient for per m of WS0026

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 6.06 m

WS0027

Coefficient for per m of WS0027

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m

WS0028

Coefficient for per m of WS0028

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 3.03 m

WS0029

Coefficient for per m of WS0029

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.04 m

WS0030

Coefficient for per m of WS0030

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 5.05 m

WS0031

Coefficient for per m of WS0031

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m

WS0032

Coefficient for per m of WS0032

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 3.0302 m

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 6x2.5 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 2x4 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 3x4 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 4x4 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 5x4 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 2x6 sq.mm

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 3x6 sq.mm

Page 107: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 108

Department of Engineering Services, MoWHS

WS0033

Coefficient for per m of WS0033

Code Description Quant Units LB0056 Wireman Gd.1 0.0338 day LB0069 Wireman Gd.2 0.0338 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m

Coefficient for per point of WS0055

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WS0056

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WS0057

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m

commissioning etc. as required - Long Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and

commissioning etc. as required - Medium Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and

Provide & Draw Single Core 1.1KV grade PVC insulated copper conductor cable in existing Steel surface conduit - 4x6 sq.mm

Wiring for light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - Short Point

WS0055

WS0056

WS0057

Page 108: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 109

Department of Engineering Services, MoWHS

MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WS0065

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WS0066

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WS0067

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and

commissioning etc. as required - Medium Point

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and

commissioning etc. as required - Short Point WS0065

Wiring for light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and WS0066

commissioning etc. as required - Long Point WS0067

Page 109: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 110

Department of Engineering Services, MoWHS

LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5800 6A switch SP 1-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WS0075

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WS0076

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each

including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WS0076

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

WS0075

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch

Page 110: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 111

Department of Engineering Services, MoWHS

Coefficient for per point of WS0077

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WS0085

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WS0086

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5824 Plate 3-module with frame 1 each

switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and

Wiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WS0086

WS0077

WS0085

Page 111: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 112

Department of Engineering Services, MoWHS

Coefficient for per point of WS0087

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5800 6A switch SP 1-way 1 each MT5902 Metal boxes - 3 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5824 Plate 3-module with frame 1 each

Coefficient for per point of WS0095

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WS0096

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

WS0095

switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

WS0087

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WS0096

Wiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3/5 pin, 6 ampere socket outlet and

Page 112: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 113

Department of Engineering Services, MoWHS

Coefficient for per point of WS0097

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WS0105

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WS0106

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each

Wiring for 3 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

WS0097

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

WS0105

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WS0106

Page 113: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 114

Department of Engineering Services, MoWHS

Coefficient for per point of WS0107

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WS0115

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 2.4 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WS0116

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 5.4 m MT5825 Plate 4-module with frame 1 each

Wiring for 5/6 pin, 6/16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 5/6 pin, 6/16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

WS0107

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Short Point

WS0115

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WS0116

Page 114: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 115

Department of Engineering Services, MoWHS

Coefficient for per point of WS0117

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5804 16A switch SP 1-way 1 each MT5810 3-Pin, 16A socket outlet, shuttered 1 each MT5903 Metal boxes - 4 Module 1 each MT6537 Wire - 2.5 mm dia. bare copper 8.9 m MT5825 Plate 4-module with frame 1 each

Coefficient for per point of WS0125

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WS0126

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Wiring for 3 pin, 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with providing and fixing 3 pin, 16 ampere socket outlet and switch including earthing the third pin, connections, painting, testing and commissioning etc. as required - Long Point

WS0117

Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Short Point

WS0125

Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Medium Point

WS0126

Page 115: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 116

Department of Engineering Services, MoWHS

Coefficient for per point of WS0127

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m

MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WS0135

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.1875 day LB0067 Painter Gd.2 0.0625 day LB0069 Wireman Gd.2 0.3125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m MT4820 Steel Conduit - 20mm x 1.6mm 1.5 m MT4825 Steel Conduit - Steel Saddle 4 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WS0136

Code Description Quant Units LB0051 Mason Gd.2 0.166 day LB0056 Wireman Gd.1 0.3333 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m MT4820 Steel Conduit - 20mm x 1.6mm 3.75 m MT4825 Steel Conduit - Steel Saddle 9 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each

Wiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with 2 way 6 ampere switch including earthing third pin, connections, painting, testing and commissioning etc. as required - Long Point

WS0127

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Short Point

WS0135

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Medium Point

WS0136

Page 116: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 117

Department of Engineering Services, MoWHS

MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4874 PVC sleev 35mm 22 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per point of WS0137

Code Description Quant Units LB0051 Mason Gd.2 0.25 day LB0056 Wireman Gd.1 0.5 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.75 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m MT4820 Steel Conduit - 20mm x 1.6mm 6.4 m MT4825 Steel Conduit - Steel Saddle 15 m MT4826 Steel Conduit - 20mm Junction box, 1 or 2 way for conduit 1 each MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4874 PVC sleev 35mm 34 each MT5895 Holders & Plugs - Ceiling Rose, 2 plate (PVC) 6A 1 each MT5802 6A switch SP 2-way 1 each MT5900 Metal boxes - 1 Module 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per m of WS0145

Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m MT4820 Steel Conduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each

Coefficient for per m of WS0146

Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m MT4820 Steel Conduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each

Wiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit with 2 way 6 ampere switch including connections, painting, testing and commissioning etc. as required - Long Point

WS0137

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 2x1 sq.mm

WS0145

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 2x1.5 sq.mm

WS0146

Page 117: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 118

Department of Engineering Services, MoWHS

Coefficient for per m of WS0147

Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4820 Steel Conduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each

WS0155

Coefficient for per m of WS0155

Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m MT4820 Steel Conduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each

WS0156

Coefficient for per m of WS0156

Code Description Quant Units LB0051 Mason Gd.2 0.0188 day LB0056 Wireman Gd.1 0.0376 day LB0067 Painter Gd.2 0.0188 day LB0069 Wireman Gd.2 0.0544 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m MT4820 Steel Conduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each

WS0165

Coefficient for per m of WS0165

Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m MT4820 Steel Conduit - 20mm x 1.6mm 1 m

Wiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm

WS0147

Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 2x2 sq.mm

Wiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required-2x2.5 sq.mm

Wiring for power circuit with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 2x4 sq.mm

Page 118: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 119

Department of Engineering Services, MoWHS

MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each

WS0175

Coefficient for per m of WS0175

Code Description Quant Units LB0051 Mason Gd.2 0.0226 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0726 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m MT4821 Steel Conduit - 25mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each

WS0176

Coefficient for per m of WS0176

Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m MT4822 Steel Conduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each

WS0177

Coefficient for per m of WS0177

Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m MT4822 Steel Conduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each

WS0178

Coefficient for per m of WS0178

Code Description Quant Units LB0051 Mason Gd.2 0.0242 day LB0056 Wireman Gd.1 0.0534 day

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 2x6 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 2x10 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 2x16 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 4x6 sq.mm

Page 119: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 120

Department of Engineering Services, MoWHS

LB0067 Painter Gd.2 0.0266 day LB0069 Wireman Gd.2 0.0776 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m MT4822 Steel Conduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each

WS0179

Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.067 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 4.04 m MT4823 Steel Conduit - 40mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each

WS0180

Coefficient for per m of WS0180

Code Description Quant Units LB0051 Mason Gd.2 0.0282 day LB0056 Wireman Gd.1 0.067 day LB0067 Painter Gd.2 0.0312 day LB0069 Wireman Gd.2 0.0908 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4.04 m MT4824 Steel Conduit - 50mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 2 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 4 each

CHAPTER 6: RE-WIRING

Coefficient for per point of WR0115

Code Description Quant Units LB0056 Wireman Gd.1 0.17 day LB0069 Wireman Gd.2 0.17 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m

Coefficient for per point of WR0116

Code Description Quant Units LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 4x10 sq.mm

Wiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable in stainless steel conduit including connections, painting, testing and commissioning etc. as required - 4x16 sq.mm

Rewiring of light, fans, call bell and 2 pin 6 ampere plug point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantling as per site requirement, painting, testing and commissioning etc. as required - Medium Point

WR0116

Coefficient for per m of WS0179

Rewiring of light, fans, call bell and 2 pin 6 ampere plug point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantling as per site requirement, painting, testing and commissioning etc. as required - Short Point

WR0115

Page 120: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 121

Department of Engineering Services, MoWHS

Coefficient for per point of WR0117

Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m

Coefficient for per point of WR0125

Code Description Quant Units LB0056 Wireman Gd.1 0.17 day LB0069 Wireman Gd.2 0.17 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m

Coefficient for per point of WR0126

Code Description Quant Units LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m

Coefficient for per point of WR0127

Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m

Coefficient for per point of WR0135

Code Description Quant Units LB0056 Wireman Gd.1 0.17 day LB0069 Wireman Gd.2 0.17 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m

Coefficient for per point of WR0136

Code Description Quant Units LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m

Rewiring of light, fans, call bell and 2 pin 6 ampere plug point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantling as per site requirement, painting, testing and commissioning etc. as required - Long Point

WR0117

Rewiring of light, fans, call bell and 2 pin 6 ampere plug point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantling as per site requirement, painting, testing and commissioning etc. as required - Short Point

WR0125

Rewiring of light, fans, call bell and 2 pin 6 ampere plug point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantling as per site requirement, painting, testing and commissioning etc. as required - Medium Point

WR0126

Rewiring of light, fans, call bell and 2 pin 6 ampere plug point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantling as per site requirement, painting, testing and commissioning etc. as required - Long Point

WR0127

Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point

WR0135

Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point

WR0136

Page 121: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 122

Department of Engineering Services, MoWHS

Coefficient for per point of WR0137

Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m

Coefficient for per point of WR0145

Code Description Quant Units LB0056 Wireman Gd.1 0.17 day LB0069 Wireman Gd.2 0.17 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m

Coefficient for per point of WR0146

Code Description Quant Units LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m

Coefficient for per point of WR0147

Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m

Coefficient for per point of WR0155

Code Description Quant Units LB0056 Wireman Gd.1 0.17 day LB0069 Wireman Gd.2 0.17 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m

Coefficient for per point of WR0156

Code Description Quant Units LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m

Coefficient for per point of WR0157

Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m

commissioning etc. as required - Long Point WR0157

Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point

WR0137

Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting,testing and commissioning etc. as required - Short Point

WR0145

Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point

WR0146

Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point

WR0147

Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point

WR0155

Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point

WR0156

Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and

Page 122: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 123

Department of Engineering Services, MoWHS

Coefficient for per point of WR0165

Code Description Quant Units LB0056 Wireman Gd.1 0.17 day LB0069 Wireman Gd.2 0.17 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m

Coefficient for per point of WR0166

Code Description Quant Units LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m

Coefficient for per point of WR0167

Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m

Coefficient for per point of WR0175

Code Description Quant Units LB0056 Wireman Gd.1 0.17 day LB0069 Wireman Gd.2 0.17 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m

Coefficient for per point of WR0176

Code Description Quant Units LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m

Coefficient for per point of WR0177

Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m

Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point

WR0176

Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point

WR0177

Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point

WR0167

Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point

WR0175

Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point

WR0165

Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point

WR0166

Page 123: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 124

Department of Engineering Services, MoWHS

Coefficient for per m of WR0185

Code Description Quant Units LB0056 Wireman Gd.1 0.045 day LB0069 Wireman Gd.2 0.045 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m

Coefficient for per m of WR0186

Code Description Quant Units LB0056 Wireman Gd.1 0.045 day LB0069 Wireman Gd.2 0.045 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m

Coefficient for per m of WR0187

Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m

Coefficient for per m of WR0200

Code Description Quant Units LB0056 Wireman Gd.1 0.045 day LB0069 Wireman Gd.2 0.045 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m

Coefficient for per m of WR0201

Code Description Quant Units LB0056 Wireman Gd.1 0.045 day LB0069 Wireman Gd.2 0.045 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m

Coefficient for per m of WR0215

Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m

Coefficient for per m of WR0216

Code Description Quant Units LB0056 Wireman Gd.1 0.057 day LB0069 Wireman Gd.2 0.057 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m

Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x10 sq.mm

WR0216

Rewiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x2.5 sq.mm

WR0201

Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x6 sq.mm

WR0215

Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x4 sq.mm

WR0187

Rewiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x2 sq.mm

WR0200

Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting testing and commissioning etc. as required - 2x1 sq.mm

WR0185

Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x1.5 sq.mm

WR0186

Page 124: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 125

Department of Engineering Services, MoWHS

Coefficient for per m of WR0217

Code Description Quant Units LB0056 Wireman Gd.1 0.0574 day LB0069 Wireman Gd.2 0.0574 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m

Coefficient for per m of WR0218

Code Description Quant Units LB0056 Wireman Gd.1 0.0574 day LB0069 Wireman Gd.2 0.0574 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m

Coefficient for per m of WR0219

Code Description Quant Units LB0056 Wireman Gd.1 0.063 day LB0069 Wireman Gd.2 0.063 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 4.04 m

Coefficient for per m of WR0220

Code Description Quant Units LB0056 Wireman Gd.1 0.063 day LB0069 Wireman Gd.2 0.063 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4.04 m

Coefficient for per point of WR0230

Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m

Coefficient for per point of WR0231

Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m

Rewiring of light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point

WR0231

Rewiring of light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point

WR0230

Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 4x16 sq.mm

WR0220

Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 4x6 sq.mm

WR0218

Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 4x10 sq.mm

WR0219

Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing HDPE/MS recessed conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x16 sq.mm

WR0217

Page 125: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 126

Department of Engineering Services, MoWHS

Coefficient for per point of WR0232

Code Description Quant Units LB0056 Wireman Gd.1 0.4 day LB0069 Wireman Gd.2 0.4 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m

Coefficient for per point of WR0240

Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m

Coefficient for per point of WR0241

Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m

Coefficient for per point of WR0242

Code Description Quant Units LB0056 Wireman Gd.1 0.4 day LB0069 Wireman Gd.2 0.4 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m

Coefficient for per point of WR0250

Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m

Coefficient for per point of WR0251

Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m

requirement, painting, testing and commissioning etc. as required - Long Point

Rewiring of light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site

requirement, painting, testing and commissioning etc. as required - Short Point WR0240

Rewiring of light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site

Rewiring of light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site

requirement, painting, testing and commissioning etc. as required - Medium Point WR0241

Rewiring of light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point

WR0232

WR0242

WR0250

testing and commissioning etc. as required - Medium Point WR0251

Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting,

testing and commissioning etc. as required - Short Point

Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting,

Page 126: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 127

Department of Engineering Services, MoWHS

Coefficient for per point of WR0252

Code Description Quant Units LB0056 Wireman Gd.1 0.4 day LB0069 Wireman Gd.2 0.4 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m

Coefficient for per point of WR0260

Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m

Coefficient for per point of WR0261

Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m

Coefficient for per point of WR0262

Code Description Quant Units LB0056 Wireman Gd.1 0.4 day LB0069 Wireman Gd.2 0.4 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m

Coefficient for per point of WR0270

Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m

Coefficient for per point of WR0271

Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m

Coefficient for per point of WR0272

Code Description Quant Units LB0056 Wireman Gd.1 0.4 day LB0069 Wireman Gd.2 0.4 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m

Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point

WR0252

Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement,painting, testing and commissioning etc. as required - Short Point

WR0260

Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point

WR0261

Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point

WR0262

Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point

WR0270

Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point

WR0271

Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point

WR0272

Page 127: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 128

Department of Engineering Services, MoWHS

Coefficient for per point of WR0280

Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m

Coefficient for per point of WR0281

Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m

Coefficient for per point of WR0282

Code Description Quant Units LB0056 Wireman Gd.1 0.4 day LB0069 Wireman Gd.2 0.4 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m

Coefficient for per point of WR0290

Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m

Coefficient for per point of WR0291

Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m

Coefficient for per point of WR0292

Code Description Quant Units LB0056 Wireman Gd.1 0.4 day LB0069 Wireman Gd.2 0.4 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m

Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement , painting,testing and commissioning etc. as required - Short Point

WR0280

Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point

WR0281

Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point

WR0282

Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point

WR0290

Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point

WR0291

Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point

WR0292

Page 128: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 129

Department of Engineering Services, MoWHS

Coefficient for per m of WR0300

Code Description Quant Units LB0056 Wireman Gd.1 0.0304 day LB0069 Wireman Gd.2 0.0304 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m

Coefficient for per m of WR0301

Code Description Quant Units LB0056 Wireman Gd.1 0.0304 day LB0069 Wireman Gd.2 0.0304 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m

Coefficient for per m of WR0302

Code Description Quant Units LB0056 Wireman Gd.1 0.0338 day LB0069 Wireman Gd.2 0.0338 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m

Coefficient for per m of WR0315

Code Description Quant Units LB0056 Wireman Gd.1 0.0304 day LB0069 Wireman Gd.2 0.0304 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m

Coefficient for per m of WR0316

Code Description Quant Units LB0056 Wireman Gd.1 0.0304 day LB0069 Wireman Gd.2 0.0304 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m

Coefficient for per m of WR0330

Code Description Quant Units LB0056 Wireman Gd.1 0.0338 day LB0069 Wireman Gd.2 0.0338 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m

Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x1 sq.mm

WR0300

Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x1.5 sq.mm

WR0301

Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x4 sq.mm

WR0302

Rewiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x2 sq.mm

WR0315

Rewiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x2.5 sq.mm

WR0316

Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x6 sq.mm

WR0330

Page 129: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 130

Department of Engineering Services, MoWHS

Coefficient for per m of WR0331

Code Description Quant Units LB0056 Wireman Gd.1 0.037 day LB0069 Wireman Gd.2 0.037 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m

Coefficient for per m of WR0332

Code Description Quant Units LB0056 Wireman Gd.1 0.037 day LB0069 Wireman Gd.2 0.037 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m

Coefficient for per point of WR0345

Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 4.4 m

Coefficient for per point of WR0346

Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.25 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 10.4 m

Coefficient for per point of WR0347

Code Description Quant Units LB0056 Wireman Gd.1 0.4286 day LB0067 Painter Gd.2 0.2143 day LB0069 Wireman Gd.2 0.4286 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 17.4 m

Coefficient for per point of WR0355

Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 4.4 m

Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x10 sq.mm

WR0331

Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC casing & capping including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x16 sq.mm

WR0332

Rewiring of light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point

WR0345

Rewiring of light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. asrequired - Medium Point

WR0346

Rewiring of light, fans, call bell and 2 pin light socket outlet with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point

WR0347

Rewiring of light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point

WR0355

Page 130: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 131

Department of Engineering Services, MoWHS

Coefficient for per point of WR0356

Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10.4 m

Coefficient for per point of WR0357

Code Description Quant Units LB0056 Wireman Gd.1 0.4286 day LB0067 Painter Gd.2 0.2143 day LB0069 Wireman Gd.2 0.4286 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 17.4 m

Coefficient for per point of WR0365

Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 4.4 m

Coefficient for per point of WR0366

Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.25 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 10.4 m

Coefficient for per point of WR0367

Code Description Quant Units LB0056 Wireman Gd.1 0.4286 day LB0067 Painter Gd.2 0.2143 day LB0069 Wireman Gd.2 0.4286 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 17.4 m

Coefficient for per point of WR0375

Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 4.4 m

painting, testing and commissioning etc. as required - Medium Point WR0366

painting, testing and commissioning etc. as required - Short Point WR0375

Rewiring of light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point

WR0356

Rewiring of light, fans, call bell and 2 pin light socket outlet with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point

WR0357

Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Short Point

WR0365

Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement,

Rewiring for 3/5 pin, 6 ampere plug point with 2 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, testing and commissioning etc. as required - Long Point

WR0367

Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement,

Page 131: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 132

Department of Engineering Services, MoWHS

Coefficient for per point of WR0376

Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.25 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 10.4 m

Coefficient for per point of WR0377

Code Description Quant Units LB0056 Wireman Gd.1 0.4286 day LB0067 Painter Gd.2 0.2143 day LB0069 Wireman Gd.2 0.4286 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17.4 m

Coefficient for per point of WR0385

Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 6.6 m

Coefficient for per point of WR0386

Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.25 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 15.6 m

Coefficient for per point of WR0387

Code Description Quant Units LB0056 Wireman Gd.1 0.4286 day LB0067 Painter Gd.2 0.2143 day LB0069 Wireman Gd.2 0.4286 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 26.1 m

commissioning etc. as required - Long Point WR0387

commissioning etc. as required - Short Point WR0385

Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point

WR0386

Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and

Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point

WR0376

Rewiring for 3/5 pin, 6 ampere plug point with 2.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point

WR0377

Rewiring for twin light point with 1 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and

Page 132: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 133

Department of Engineering Services, MoWHS

Coefficient for per point of WR0395

Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 6.6 m

Coefficient for per point of WR0396

Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 15.6 m

Coefficient for per point of WR0397

Code Description Quant Units LB0056 Wireman Gd.1 0.4286 day LB0067 Painter Gd.2 0.2143 day LB0069 Wireman Gd.2 0.4286 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 26.1 m

Coefficient for per point of WR0405

Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 4.4 m

Coefficient for per point of WR0406

Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.25 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 10.4 m

Coefficient for per point of WR0407

Code Description Quant Units LB0056 Wireman Gd.1 0.4286 day LB0067 Painter Gd.2 0.2143 day LB0069 Wireman Gd.2 0.4286 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 17.4 m

requirement, painting, testing and commissioning etc. as required - Long Point WR0407

requirement, painting, testing and commissioning etc. as required - Short Point WR0405

Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Medium Point

WR0406

Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site

and commissioning etc. as required - Medium Point WR0396

Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - Long Point

WR0397

Rewiring for 3/5 pin, 6 /16 ampere /3 pin 16 ampere plug point with 4 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site

Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testingand commissioning etc. as required - Short Point

WR0395

Rewiring for twin light point with 1.5 sq.mm 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing

Page 133: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 134

Department of Engineering Services, MoWHS

Coefficient for per m of WR0415

Code Description Quant Units LB0056 Wireman Gd.1 0.0332 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0332 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 2.02 m

Coefficient for per m of WR0416

Code Description Quant Units LB0056 Wireman Gd.1 0.0332 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0332 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 2.02 m

Coefficient for per m of WR0417

Code Description Quant Units LB0056 Wireman Gd.1 0.0354 day LB0067 Painter Gd.2 0.0266 day LB0069 Wireman Gd.2 0.0354 day MT4074 PVC insulated Single Core Copper conductor (1.1KV) - 4 sq.mm 2.02 m

Coefficient for per m of WR0430

Code Description Quant Units LB0056 Wireman Gd.1 0.0332 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0332 day MT4072 PVC insulated Single Core Copper conductor (1.1KV) - 2 sq.mm 2.02 m

Coefficient for per m of WR0431

Code Description Quant Units LB0056 Wireman Gd.1 0.0332 day LB0067 Painter Gd.2 0.025 day LB0069 Wireman Gd.2 0.0332 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 2.02 m

Coefficient for per m of WR0445

Code Description Quant Units LB0056 Wireman Gd.1 0.0354 day LB0067 Painter Gd.2 0.0266 day LB0069 Wireman Gd.2 0.0354 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 2.02 m

and commissioning etc. as required - 2x6 sq.mm WR0445

and commissioning etc. as required - 2x2 sq.mm WR0430

Rewiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x2.5 sq.mm

WR0431

Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing

painting, testing and commissioning etc. as required - 2x1.5 sq.mm WR0416

Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x4 sq.mm

WR0417

Rewiring for lighting circuit with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing

Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x1 sq.mm

WR0415

Rewiring for points in excess length above long points with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement,

Page 134: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 135

Department of Engineering Services, MoWHS

Coefficient for per m of WR0446

Code Description Quant Units LB0056 Wireman Gd.1 0.0372 day LB0067 Painter Gd.2 0.0266 day LB0069 Wireman Gd.2 0.0372 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 2.02 m

Coefficient for per m of WR0447

Code Description Quant Units LB0056 Wireman Gd.1 0.0372 day LB0067 Painter Gd.2 0.0266 day LB0069 Wireman Gd.2 0.0372 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 2.02 m

Coefficient for per m of WR0448

Code Description Quant Units LB0056 Wireman Gd.1 0.0354 day LB0067 Painter Gd.2 0.0278 day LB0069 Wireman Gd.2 0.0354 day MT4075 PVC insulated Single Core Copper conductor (1.1KV) - 6 sq.mm 4.04 m

Coefficient for per m of WR0449

Code Description Quant Units LB0056 Wireman Gd.1 0.0408 day LB0067 Painter Gd.2 0.03 day LB0069 Wireman Gd.2 0.0408 day MT4076 PVC insulated Single Core Copper conductor (1.1KV) - 10 sq.mm 4.04 m

Coefficient for per m of WR0450

Code Description Quant Units LB0056 Wireman Gd.1 0.0408 day LB0067 Painter Gd.2 0.03 day LB0069 Wireman Gd.2 0.0408 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4.04 m

CHAPTER 7: CONDUITING

CD0045

Coefficient for per m of CD0045

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.0472 day

and commissioning etc. as required - 4x10 sq.mm

Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing WR0449

Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 4x16 sq.mm

WR0450

Supplying and fixing of PVC casing & capping on surface including cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - 13x12x1.2mm

and commissioning etc. as required - 2x16 sq.mm WR0447

Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 4x6 sq.mm

WR0448

Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing and commissioning etc. as required - 2x10 sq.mm

WR0446

Rewiring for sub-main with 1.1kV grade, PVC insulated copper conductor cable on existing PVC/MS/Steel surface conduit including dismantalling as per site requirement, painting, testing

Page 135: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 136

Department of Engineering Services, MoWHS

MT4873 PVC sleev 25mm 6.6 each MT4940 PVC Casing & Cappings - 12x12 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m

CD0046

Coefficient for per m of CD0046

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.0472 day MT4873 PVC sleev 25mm 6.6 each MT4944 PVC Casing & Cappings - 20x12 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.2 m

CD0047

Coefficient for per m of CD0047

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.0524 day MT4873 PVC sleev 25mm 6.6 each MT4945 PVC Casing & Cappings - 25x10 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.3 m

CD0048

Coefficient for per m of CD0048

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.0524 day MT4873 PVC sleev 25mm 6.6 each MT4946 PVC Casing & Cappings - 30x10 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.3 m

CD0049

Coefficient for per m of CD0049

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.032 day LB0069 Wireman Gd.2 0.056 day MT4873 PVC sleev 25mm 6.6 each MT4947 PVC Casing & Cappings - 40x20 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.3 m

CD0050

Coefficient for per m of CD0050

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.032 day LB0069 Wireman Gd.2 0.056 day MT4873 PVC sleev 25mm 6.6 each MT4948 PVC Casing & Cappings - 50x20 mm 1 m MT4949 PVC Casing & Cappings - Corner/Tee 0.3 m

Supplying and fixing of PVC casing & capping on surface including cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - 20x12x1.2mm

Supplying and fixing of PVC casing & capping on surface including cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - 25x10x1.2mm

Supplying and fixing of PVC casing & capping on surface including cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - 32x10x1.2mm

Supplying and fixing of PVC casing & capping on surface including cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - 40x10x1.2mm

Supplying and fixing of PVC casing & capping on surface including cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - 50x10x1.2mm

Page 136: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 137

Department of Engineering Services, MoWHS

Coefficient for per point of CD0060

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4860 PVC Boxes - 1 Module 1 each MT4873 PVC sleev 25mm 19 each MT4940 PVC Casing & Cappings - 12x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m

Coefficient for per point of CD0061

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.11 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.27 day MT4860 PVC Boxes - 1 Module 1 each MT4873 PVC sleev 25mm 39 each MT4940 PVC Casing & Cappings - 12x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m

Coefficient for per point of CD0062

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4860 PVC Boxes - 1 Module 1 each MT4873 PVC sleev 25mm 62 each MT4940 PVC Casing & Cappings - 12x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m

Coefficient for per point of CD0070

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4860 PVC Boxes - 1 Module 1 each MT4873 PVC sleev 25mm 19 each MT4944 PVC Casing & Cappings - 20x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m

as required - Short Point

Supplying and fixing of PVC casing & capping on surface for twin control light point with all accessories such as switch board, round block, cup washer, screws, bends, elbows, Tees, corners, etc. complete

cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point CD0061

Supplying and fixing of PVC casing & capping on surface for light /call bell/fan/ 2 pin socket outlet/ 3/5 pin 6 ampere plug point along with all accessories such as switch board, round block, cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point

CD0062

cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - Short Point CD0060

Supplying and fixing of PVC casing & capping on surface for light /call bell/fan/ 2 pin socket outlet/ 3/5 pin 6 ampere plug point along with all accessories such as switch board, round block,

CD0070

Supplying and fixing of PVC casing & capping on surface for light /call bell/fan/ 2 pin socket outlet/ 3/5 pin 6 ampere plug point along with all accessories such as switch board, round block,

Page 137: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 138

Department of Engineering Services, MoWHS

Coefficient for per point of CD0071

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.11 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.27 day MT4860 PVC Boxes - 1 Module 1 each MT4873 PVC sleev 25mm 39 each MT4944 PVC Casing & Cappings - 20x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m

Coefficient for per point of CD0072

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4860 PVC Boxes - 1 Module 1 each MT4873 PVC sleev 25mm 62 each MT4944 PVC Casing & Cappings - 20x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m

Coefficient for per point of CD0080

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4863 PVC Boxes - 4 Module 1 each MT4873 PVC sleev 25mm 19 each MT4944 PVC Casing & Cappings - 20x12 mm 2 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m

Coefficient for per point of CD0081

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.11 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.27 day MT4863 PVC Boxes - 4 Module 1 each MT4873 PVC sleev 25mm 39 each MT4944 PVC Casing & Cappings - 20x12 mm 5 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m

complete as required - Medium Point

Supplying and fixing of PVC casing & capping on surface for 3/5 pin 6/16 ampere plug point along with all accessories such as switch board, round block, cup washer, screws, bends, elbows, Tees, corners, etc.

Supplying and fixing of PVC casing & capping on surface for twin control light point with all accessories such as switch board, round block, cup washer, screws, bends, elbows, Tees, corners, etc. complete

CD0081

as required - Long Point CD0072

Supplying and fixing of PVC casing & capping on surface for 3/5 pin 6/16 ampere plug point along with all accessories such as switch board, round block, cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - Short Point

CD0080

Supplying and fixing of PVC casing & capping on surface for twin control light point with all accessories such as switch board, round block, cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point

CD0071

Page 138: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 139

Department of Engineering Services, MoWHS

Coefficient for per point of CD0082

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4863 PVC Boxes - 4 Module 1 each MT4873 PVC sleev 25mm 62 each MT4944 PVC Casing & Cappings - 20x12 mm 8.5 m MT4949 PVC Casing & Cappings - Corner/Tee 2 m

CD0090

Coefficient for per m of CD0090

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.0472 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4840 PVC Conduit - 20 mm,18SWG 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 3.4 each

CD0091

Coefficient for per m of CD0091

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.0524 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4841 PVC Conduit - 25 mm,16SWG 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 3.4 each

CD0092

Coefficient for per m of CD0092

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.0524 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4842 PVC Conduit - 32 mm,14SWG 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 3.4 each

CD0093

Coefficient for per m of CD0093

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day

Supplying and fixing of PVC conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 25mm

Supplying and fixing of PVC conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 32mm

Supplying and fixing of PVC conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 40mm

Supplying and fixing of PVC casing & capping on surface for 3/5 pin 6/16 ampere plug point along with all accessories such as switch board, round block, cup washer, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point

CD0082

Supplying and fixing of PVC conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 20mm

Page 139: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 140

Department of Engineering Services, MoWHS

LB0056 Wireman Gd.1 0.052 day LB0069 Wireman Gd.2 0.056 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4843 PVC Conduit - 40 mm,14SWG 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 3.4 each

CD0094

Coefficient for per m of CD0094

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.052 day LB0069 Wireman Gd.2 0.056 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4844 PVC Conduit - 50 mm,14SWG 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 3.4 each

Coefficient for per point of CD0105

Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 2 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each

Coefficient for per point of CD0106

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.11 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.27 day MT4809 M.S Coduit - M.S Saddle 9 each MT4840 PVC Conduit - 20 mm,18SWG 5 m MT4860 PVC Boxes - 1 Module 1 each MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 21 each

as required - Medium Point

CD0105

CD0106

Supplying and fixing of PVC conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 50mm

Supplying and fixing of PVC conduit on surface for light call bell/fan/ 2 pin socket outlet along with all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. complete as required - Short Point

Supplying and fixing of PVC conduit on surface for light call bell/fan/ 2 pin socket outlet along with all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. complete

Page 140: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 141

Department of Engineering Services, MoWHS

Coefficient for per point of CD0107

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4809 M.S Coduit - M.S Saddle 15 each MT4840 PVC Conduit - 20 mm,18SWG 8.5 m MT4860 PVC Boxes - 1 Module 1 each MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 33 each

CD0115

Coefficient for per point of CD0115

Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 2 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each

CD0116

Coefficient for per point of CD0116

Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 2 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 21 each

CD0117

Coefficient for per point of CD0117

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4809 M.S Coduit - M.S Saddle 15 each

as required - Long Point

Supplying and fixing of PVC conduit on surface for light call bell/fan/ 2 pin socket outlet along with all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. complete

Supplying and fixing of PVC conduit on surface for twin control light point along with all accessories such as switch board, screws, bends, elbows, Tees, corners, etc. complete as required -Short Point

Supplying and fixing of PVC conduit on surface for twin control light point along with all accessories such as switch board, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point

Supplying and fixing of PVC conduit on surface for twin control light point along with all accessories such as switch board, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point

CD0107

Page 141: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 142

Department of Engineering Services, MoWHS

MT4840 PVC Conduit - 20 mm,18SWG 8.5 m MT4860 PVC Boxes - 1 Module 1 each MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 33 each

Coefficient for per point of CD0125

Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 2 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 12 each

Coefficient for per point of CD0126

Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4809 M.S Coduit - M.S Saddle 4 each MT4840 PVC Conduit - 20 mm,18SWG 2 m MT4863 PVC Boxes - 4 Module 1 each

MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 21 each

Coefficient for per point of CD0127

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4809 M.S Coduit - M.S Saddle 15 each MT4840 PVC Conduit - 20 mm,18SWG 8.5 m MT4863 PVC Boxes - 4 Module 1 each MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 33 each

complete as required - Long Point

Supplying and fixing of PVC conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc.

CD0125

CD0127

Supplying and fixing of PVC conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc.complete as required - Short Point

Supplying and fixing of PVC conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point

CD0126

Page 142: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 143

Department of Engineering Services, MoWHS

CD0135

Coefficient for per m of CD0135

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.027 day LB0069 Wireman Gd.2 0.0472 day MT4820 Steel Conduit - 20mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 1.7 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 3.4 each

CD0136

Coefficient for per m of CD0136

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.0524 day MT4821 Steel Conduit - 25mm x 1.6mm 1 m MT4825 Steel Conduit - Steel Saddle 1.7 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 3.4 each

CD0137

Coefficient for per m of CD0137

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.0524 day MT4822 Steel Conduit - 32mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 1.7 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 3.4 each

CD0138

Coefficient for per m of CD0138

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.052 day LB0069 Wireman Gd.2 0.056 day MT4823 Steel Conduit - 40mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 1.7 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 3.4 each

CD0139

Coefficient for per m of CD0139

Code Description Quant Units LB0051 Mason Gd.2 0.0224 day LB0056 Wireman Gd.1 0.052 day

Supplying and fixing of Stainless steel conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 20mm

Supplying and fixing of Stainless steel conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 25mm

Supplying and fixing of Stainless steel conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 32mm

Supplying and fixing of Stainless steel conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc.complete as required - 40mm

Supplying and fixing of Stainless steel conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 50mm

Page 143: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 144

Department of Engineering Services, MoWHS

LB0069 Wireman Gd.2 0.056 day MT4824 Steel Conduit - 50mm x 2mm 1 m MT4825 Steel Conduit - Steel Saddle 1.7 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 0.08 each MT4828 Steel Conduit - 20mm socket for conduit 0.3 each MT4874 PVC sleev 35mm 3.4 each

Coefficient for per point of CD0150

Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4820 Steel Conduit - 20mm x 1.6mm 2 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 19 each MT5900 Metal boxes - 1 Module 1 each

Coefficient for per point of CD0151

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.11 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.27 day MT4820 Steel Conduit - 20mm x 1.6mm 5 m MT4825 Steel Conduit - Steel Saddle 9 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 39 each MT5900 Metal boxes - 1 Module 1 each

Coefficient for per point of CD0152

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4820 Steel Conduit - 20mm x 1.6mm 8.5 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 62 each MT5900 Metal boxes - 1 Module 1 each

Supplying and fixing of Stainless steel conduit on surface for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc.complete as required - Short Point

CD0150

Supplying and fixing of Stainless steel conduit on surface for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc.complete as required - Medium Point

CD0151

Supplying and fixing of Stainless steel conduit on surface for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc.complete as required - Long Point

CD152

Page 144: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 145

Department of Engineering Services, MoWHS

Coefficient for per point of CD0160

Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4820 Steel Conduit - 20mm x 1.6mm 2 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 19 each MT5900 Metal boxes - 1 Module 1 each

Coefficient for per point of CD0161

Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4820 Steel Conduit - 20mm x 1.6mm 2 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 39 each MT5900 Metal boxes - 1 Module 1 each

Coefficient for per point of CD0162

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4820 Steel Conduit - 20mm x 1.6mm 8.5 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 62 each MT5900 Metal boxes - 1 Module 1 each

Coefficient for per point of CD0170

Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4820 Steel Conduit - 20mm x 1.6mm 2 m

Supplying and fixing of Stainless steel conduit on surface for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete asrequired - Short Point

CD0160

Supplying and fixing of Stainless steel conduit on surface for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point

CD0161

Supplying and fixing of Stainless steel conduit on surface for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point

CD0162

Supplying and fixing of Stainless steel conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Short Point

CD0170

Page 145: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 146

Department of Engineering Services, MoWHS

MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 19 each MT5903 Metal boxes - 4 Module 1 each

Coefficient for per point of CD0171

Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4820 Steel Conduit - 20mm x 1.6mm 2 m MT4825 Steel Conduit - Steel Saddle 4 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each

MT4828 Steel Conduit - 20mm socket for conduit 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 39 each MT5903 Metal boxes - 4 Module 1 each

Coefficient for per point of CD0172

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4820 Steel Conduit - 20mm x 1.6mm 8.5 m MT4825 Steel Conduit - Steel Saddle 15 m MT4827 Steel Conduit - 20mm Inspection bend for conduit 1 each MT4828 Steel Conduit - 20mm socket for conduit 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4873 PVC sleev 25mm 62 each MT5903 Metal boxes - 4 Module 1 each

CD0180

Coefficient for per m of CD0180

Code Description Quant Units LB0051 Mason Gd.2 0.02 day LB0056 Wireman Gd.1 0.04 day LB0067 Painter Gd.2 0.0225 day LB0069 Wireman Gd.2 0.0625 day MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4807 M.S Coduit - Inspection bend 0.04 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 3.4 each

CD0181

Coefficient for per m of CD0181

Code Description Quant Units LB0051 Mason Gd.2 0.02 day LB0056 Wireman Gd.1 0.04 day

Supplying and fixing of Stainless steel conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point

CD0171

Supplying and fixing of Stainless steel conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point

CD0172

Supplying and fixing of MS conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete asrequired - 20mm

Supplying and fixing of MS conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 25mm

Page 146: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 147

Department of Engineering Services, MoWHS

LB0067 Painter Gd.2 0.0225 day LB0069 Wireman Gd.2 0.0625 day MT4802 M.S Coduit - 25mm x 1.6mm 1 m MT4807 M.S Coduit - Inspection bend 0.08 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 3.4 each

CD0182

Coefficient for per m of CD0182

Code Description Quant Units LB0051 Mason Gd.2 0.025 day LB0056 Wireman Gd.1 0.0425 day LB0067 Painter Gd.2 0.0225 day LB0069 Wireman Gd.2 0.065 day MT4803 M.S Coduit - 32mm x 2mm 1 m MT4807 M.S Coduit - Inspection bend 0.08 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 3.4 each

CD0183

Coefficient for per m of CD0183

Code Description Quant Units LB0051 Mason Gd.2 0.025 day LB0056 Wireman Gd.1 0.0425 day LB0067 Painter Gd.2 0.0225 day LB0069 Wireman Gd.2 0.065 day MT4804 M.S Coduit - 40mm x 2mm 1 m MT4807 M.S Coduit - Inspection bend 0.08 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 3.4 each

CD0184

Coefficient for per m of CD0184

Code Description Quant Units LB0051 Mason Gd.2 0.02 day LB0056 Wireman Gd.1 0.045 day LB0067 Painter Gd.2 0.0225 day LB0069 Wireman Gd.2 0.0675 day MT4805 M.S Coduit - 50mm x 2mm 1 m MT4807 M.S Coduit - Inspection bend 0.08 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 3.4 each

Coefficient for per point of CD0195

Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.137 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.212 day MT4801 M.S Coduit - 20mm x 1.6mm 2 m

Supplying and fixing of MS conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 32mm

Supplying and fixing of MS conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 40mm

Supplying and fixing of MS conduit on surface including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 50mm

Supplying and fixing of MS conduit on surface for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Short Point

CD0195

Page 147: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 148

Department of Engineering Services, MoWHS

MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4809 M.S Coduit - M.S Saddle 4 each MT4874 PVC sleev 35mm 3.4 each MT5900 Metal boxes - 1 Module 1 each

Coefficient for per point of CD0196

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.275 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.4 day MT4801 M.S Coduit - 20mm x 1.6mm 5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 2 each MT4809 M.S Coduit - M.S Saddle 9 each MT4874 PVC sleev 35mm 3.4 each MT5900 Metal boxes - 1 Module 1 each

Coefficient for per point of CD0197

Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.3643 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.6143 day MT4801 M.S Coduit - 20mm x 1.6mm 8.5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 3 each MT4809 M.S Coduit - M.S Saddle 15 each MT4874 PVC sleev 35mm 3.4 each MT5900 Metal boxes - 1 Module 1 each

Coefficient for per point of CD0200

Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.137 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.212 day MT4801 M.S Coduit - 20mm x 1.6mm 2 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4809 M.S Coduit - M.S Saddle 4 each MT4874 PVC sleev 35mm 12 each MT5900 Metal boxes - 1 Module 1 each

Supplying and fixing of MS conduit on surface for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point

CD0196

Supplying and fixing of MS conduit on surface for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point

CD0197

Supplying and fixing of MS conduit on surface for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as requiredrequired - Short Point

CD0200

Page 148: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 149

Department of Engineering Services, MoWHS

Coefficient for per point of CD0201

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.275 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.4 day MT4801 M.S Coduit - 20mm x 1.6mm 2 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each

MT4808 M.S Coduit - socket for conduit 2 each MT4809 M.S Coduit - M.S Saddle 4 each MT4874 PVC sleev 35mm 21 each MT5900 Metal boxes - 1 Module 1 each

Coefficient for per point of CD0202

Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.3643 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.6143 day MT4801 M.S Coduit - 20mm x 1.6mm 8.5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 3 each MT4809 M.S Coduit - M.S Saddle 15 each MT4874 PVC sleev 35mm 33 each MT5900 Metal boxes - 1 Module 1 each

Coefficient for per point of CD0210

Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.137 day LB0067 Painter Gd.2 0.05 day LB0069 Wireman Gd.2 0.212 day MT4801 M.S Coduit - 20mm x 1.6mm 2 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4809 M.S Coduit - M.S Saddle 4 each MT4874 PVC sleev 35mm 12 each MT5903 Metal boxes - 4 Module 1 each

Coefficient for per point of CD0211

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.275 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.4 day

Supplying and fixing of MS conduit on surface for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required-Medium Point

CD0201

Supplying and fixing of MS conduit on surface for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required-Long Point

CD0202

Supplying and fixing of MS conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Short Point

CD0210

Supplying and fixing of MS conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point

CD0211

Page 149: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 150

Department of Engineering Services, MoWHS

MT4801 M.S Coduit - 20mm x 1.6mm 2 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each

MT4808 M.S Coduit - socket for conduit 2 each MT4809 M.S Coduit - M.S Saddle 4 each MT4874 PVC sleev 35mm 21 each MT5903 Metal boxes - 4 Module 1 each

Coefficient for per point of CD0212

Code Description Quant Units LB0051 Mason Gd.2 0.1875 day LB0056 Wireman Gd.1 0.3643 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.6143 day MT4801 M.S Coduit - 20mm x 1.6mm 8.5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 3 each MT4809 M.S Coduit - M.S Saddle 15 each MT4874 PVC sleev 35mm 33 each MT5903 Metal boxes - 4 Module 1 each

CD0220

Coefficient for per m of CD0220

Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0352 day LB0069 Wireman Gd.2 0.1232 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4850 HDPE pipe - 20mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 2 each

CD0221

Coefficient for per m of CD0221

Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0352 day LB0069 Wireman Gd.2 0.1232 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4851 HDPE pipe - 25mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 2 each

CD0222

Coefficient for per m of CD0222

Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0374 day LB0069 Wireman Gd.2 0.1254 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4852 HDPE pipe - 32mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 2 each

Supplying and fixing of MS conduit on surface for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point

CD0212

Supplying and fixing of HDPE pipe on recessed including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 20mm

Supplying and fixing of HDPE pipe on recessed including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 25mm

Supplying and fixing of HDPE pipe on recessed including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 32mm

Page 150: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 151

Department of Engineering Services, MoWHS

CD0223

Coefficient for per m of CD00223

Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0374 day LB0069 Wireman Gd.2 0.1254 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4853 HDPE pipe - 40mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 2 each

CD0224

Coefficient for per m of CD0224

Code Description Quant Units LB0051 Mason Gd.2 0.1004 day LB0056 Wireman Gd.1 0.0396 day LB0069 Wireman Gd.2 0.1276 day MT4809 M.S Coduit - M.S Saddle 1.7 each MT4854 HDPE pipe - 50mm 1 m MT4870 PVC Socket 0.3 each MT4872 Inspection bend for conduit 0.08 each MT4874 PVC sleev 35mm 2 each

Coefficient for per point of CD0235

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.0833 day LB0069 Wireman Gd.2 0.525 day MT4809 M.S Coduit - M.S Saddle 3 each MT4850 HDPE pipe - 20mm 2 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 9 each

Coefficient for per point of CD0236

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.1666 day LB0069 Wireman Gd.2 0.825 day MT4809 M.S Coduit - M.S Saddle 5 each MT4850 HDPE pipe - 20mm 5 m MT4860 PVC Boxes - 1 Module 1 each MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 13 each

as required - Medium Point

Supplying and fixing of HDPE pipe on recessed for light call bell/fan/ 2 pin socket outlet along with all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. complete

Supplying and fixing of HDPE pipe on recessed including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 40mm

CD0235

CD0236

Supplying and fixing of HDPE pipe on recessed for light call bell/fan/ 2 pin socket outlet along with all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. complete as required - Short Point

Supplying and fixing of HDPE pipe on recessed including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 50mm

Page 151: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 152

Department of Engineering Services, MoWHS

Coefficient for per point of CD0237

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 1.125 day MT4809 M.S Coduit - M.S Saddle 8 each MT4850 HDPE pipe - 20mm 8.5 m MT4860 PVC Boxes - 1 Module 1 each MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 19 each

Coefficient for per point of CD0245

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.0833 day LB0069 Wireman Gd.2 0.525 day MT4809 M.S Coduit - M.S Saddle 3 each MT4850 HDPE pipe - 20mm 2 m MT4860 PVC Boxes - 1 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 9 each

CD0246

Coefficient for per point of CD0246

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.1666 day LB0069 Wireman Gd.2 0.825 day MT4809 M.S Coduit - M.S Saddle 5 each MT4850 HDPE pipe - 20mm 5 m MT4860 PVC Boxes - 1 Module 1 each MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 13 each

CD0247

Coefficient for per point of CD0247

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 1.125 day MT4809 M.S Coduit - M.S Saddle 8 each MT4850 HDPE pipe - 20mm 8.5 m MT4860 PVC Boxes - 1 Module 1 each MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 19 each

Supplying and fixing of HDPE pipe on recessed for twin control light point along with all accessories such as switch board, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point

as required - Long Point

Supplying and fixing of HDPE pipe on recessed for light call bell/fan/ 2 pin socket outlet along with all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. complete

Short Point

CD0237

CD0245

Supplying and fixing of HDPE pipe on recessed for twin control light point along with all accessories such as switch board, screws, bends, elbows, Tees, corners, etc. complete as required - Medium Point

Supplying and fixing of HDPE pipe on recessed for twin control light point along with all accessories such as switch board, screws, bends, elbows, Tees, corners, etc. complete as required-

Page 152: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 153

Department of Engineering Services, MoWHS

Coefficient for per point of CD0255

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.0833 day LB0069 Wireman Gd.2 0.525 day MT4809 M.S Coduit - M.S Saddle 3 each MT4850 HDPE pipe - 20mm 2 m MT4863 PVC Boxes - 4 Module 1 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 9 each

Coefficient for per point of CD0256

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.1666 day LB0069 Wireman Gd.2 0.825 day MT4809 M.S Coduit - M.S Saddle 5 each MT4850 HDPE pipe - 20mm 5 m MT4863 PVC Boxes - 4 Module 1 each MT4870 PVC Socket 2 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 13 each

Coefficient for per point of CD0257

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 1.125 day MT4809 M.S Coduit - M.S Saddle 8 each MT4850 HDPE pipe - 20mm 8.5 m MT4863 PVC Boxes - 4 Module 1 each MT4870 PVC Socket 3 each MT4871 Junction box, 1 or 2 way for conduit 1 each MT4872 Inspection bend for conduit 1 each MT4874 PVC sleev 35mm 19 each

CD0265

Coefficient for per m of CD0265

Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.14 day MT4801 M.S Coduit - 20mm x 1.6mm 1 m MT4807 M.S Coduit - Inspection bend 0.04 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 2 each

complete as required - Short Point

Supplying and fixing of HDPE pipe on recessed for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc.

Supplying and fixing of HDPE pipe on recessed for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point

CD0255

complete as required - Medium Point CD0256

CD0257

Supplying and fixing of recessed MS conduit including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 20mm

Supplying and fixing of HDPE pipe on recessed for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc.

Page 153: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 154

Department of Engineering Services, MoWHS

CD0266

Coefficient for per m of CD0266

Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.14 day MT4802 M.S Coduit - 25mm x 1.6mm 1 m MT4807 M.S Coduit - Inspection bend 0.08 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 2 each

CD0267

Coefficient for per m of CD0267

Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0425 day LB0069 Wireman Gd.2 0.1425 day MT4803 M.S Coduit - 32mm x 2mm 1 m MT4807 M.S Coduit - Inspection bend 0.08 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 2 each

CD0268

Coefficient for per m of CD0268

Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0425 day LB0069 Wireman Gd.2 0.1425 day MT4804 M.S Coduit - 40mm x 2mm 1 m MT4807 M.S Coduit - Inspection bend 0.08 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 2 each

CD0269

Coefficient for per m of CD0269

Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.045 day LB0069 Wireman Gd.2 0.145 day MT4805 M.S Coduit - 50mm x 2mm 1 m MT4807 M.S Coduit - Inspection bend 0.08 each MT4808 M.S Coduit - socket for conduit 0.3 each MT4809 M.S Coduit - M.S Saddle 1.7 each MT4874 PVC sleev 35mm 2 each

Coefficient for per point of CD0280

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.0833 day

as required - Short Point

Supplying and fixing of recessed MS conduit for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. complete

Supplying and fixing of recessed MS conduit including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 50mm

Supplying and fixing of recessed MS conduit including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 40mm

CD0280

Supplying and fixing of recessed MS conduit including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 25mm

Supplying and fixing of recessed MS conduit including all accessories such as screws, bends, elbows, Tees, corners, etc. complete as required - 32mm

Page 154: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 155

Department of Engineering Services, MoWHS

LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 0.5833 day MT4801 M.S Coduit - 20mm x 1.6mm 2 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4809 M.S Coduit - M.S Saddle 3 each MT4874 PVC sleev 35mm 9 each MT5900 Metal boxes - 1 Module 1 each

Coefficient for per point of CD0281

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.1666 day LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 0.9166 day MT4801 M.S Coduit - 20mm x 1.6mm 5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 2 each MT4809 M.S Coduit - M.S Saddle 5 each MT4874 PVC sleev 35mm 13 each MT5900 Metal boxes - 1 Module 1 each

Coefficient for per point of CD0282

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 1.25 day MT4801 M.S Coduit - 20mm x 1.6mm 8.5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 3 each MT4809 M.S Coduit - M.S Saddle 8 each MT4874 PVC sleev 35mm 19 each MT5900 Metal boxes - 1 Module 1 each

Coefficient for per point of CD0290

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.0833 day LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 0.5833 day MT4801 M.S Coduit - 20mm x 1.6mm 2 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4809 M.S Coduit - M.S Saddle 3 each MT4874 PVC sleev 35mm 9 each MT5900 Metal boxes - 1 Module 1 each

Supplying and fixing of recessed MS conduit for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Short Point

CD0290

Supplying and fixing of recessed MS conduit for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. completeas required - Medium Point

CD0281

Supplying and fixing of recessed MS conduit for light call bell/fan/ 2 pin socket outlet along all accessories such as switch board, round block, screws, bends, elbows, Tees, corners, etc. complete required - Long Point

CD0282

Page 155: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 156

Department of Engineering Services, MoWHS

Coefficient for per point of CD0291

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.1666 day LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 0.9166 day MT4801 M.S Coduit - 20mm x 1.6mm 5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 2 each MT4809 M.S Coduit - M.S Saddle 5 each MT4874 PVC sleev 35mm 13 each MT5900 Metal boxes - 1 Module 1 each

Coefficient for per point of CD0292

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 1.25 day MT4801 M.S Coduit - 20mm x 1.6mm 8.5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 3 each MT4809 M.S Coduit - M.S Saddle 8 each MT4874 PVC sleev 35mm 19 each MT5900 Metal boxes - 1 Module 1 each

Coefficient for per point of CD0300

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.0833 day LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 0.5833 day MT4801 M.S Coduit - 20mm x 1.6mm 2 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4809 M.S Coduit - M.S Saddle 3 each MT4874 PVC sleev 35mm 9 each MT5903 Metal boxes - 4 Module 1 each

Coefficient for per point of CD0301

Code Description Quant Units LB0051 Mason Gd.2 0.75 day LB0056 Wireman Gd.1 0.1666 day LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 0.9166 day MT4801 M.S Coduit - 20mm x 1.6mm 5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each

Supplying and fixing of recessed MS conduit for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, complete as required - Medium Point

CD0301

Supplying and fixing of recessed MS conduit for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required - Long Point

CD0292

Supplying and fixing of recessed MS conduit for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners,etc.etc. complete as required - Short Point

CD0300

Supplying and fixing of recessed MS conduit for twin control light point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. complete as required -Medium Point

CD0291

Page 156: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 157

Department of Engineering Services, MoWHS

MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 2 each MT4809 M.S Coduit - M.S Saddle 5 each MT4874 PVC sleev 35mm 13 each MT5903 Metal boxes - 4 Module 1 each

Coefficient for per point of CD0302

Code Description Quant Units LB0051 Mason Gd.2 1 day LB0056 Wireman Gd.1 0.25 day LB0067 Painter Gd.2 0.01 day LB0069 Wireman Gd.2 1.25 day MT4801 M.S Coduit - 20mm x 1.6mm 8.5 m MT4806 M.S Coduit - Junction box, 1 or 2 way 1 each MT4807 M.S Coduit - Inspection bend 1 each MT4808 M.S Coduit - socket for conduit 3 each MT4809 M.S Coduit - M.S Saddle 8 each MT4874 PVC sleev 35mm 19 each MT5903 Metal boxes - 4 Module 1 each

CD0310

Coefficient for per m of CD0310Code Description Quant UnitsLB0051 Mason Gd.2 0.0224 dayLB0056 Wireman Gd.1 0.032 dayLB0069 Wireman Gd.2 0.056 dayMT7000 Mini trunking 32x12.5mm 1 mMT7002 Changeable internal angle 0.3 eachMT7002 Changeable external angle 0.21 eachMT7003 Changeable flat angle 0.32 eachMT7001 End cap 0.03 each

CD0311

Coefficient for per m of CD0311Code Description Quant UnitsLB0051 Mason Gd.2 0.0224 dayLB0056 Wireman Gd.1 0.032 dayLB0069 Wireman Gd.2 0.056 dayMT7005 Mini trunking 32x16mm 1 mMT7007 Changeable internal angle 0.3 eachMT7007 Changeable external angle 0.21 eachMT7008 Changeable flat angle 0.32 eachMT7006 End cap 0.03 each

CD0312

Coefficient for per m of CD0312Code Description Quant UnitsLB0051 Mason Gd.2 0.0224 dayLB0056 Wireman Gd.1 0.032 dayLB0069 Wireman Gd.2 0.056 dayMT7010 Mini trunking 32x20mm 1 mMT7007 Changeable internal angle 0.3 eachMT7007 Changeable external angle 0.21 eachMT7008 Changeable flat angle 0.32 eachMT7011 End cap 0.03 each

Supplying and fixing of recessed MS conduit for 3/5 pin 6/16 ampere 3 pin 16 ampere plug point along with all accessories such as switch board, junction box, screws, bends, elbows, Tees, corners, etc. etc. complete as required - Long Point

CD0302

Suplying and fixing of PVC mini trunking on surface including changeable internal angles, external angles, flat anlges etc. complete as required- 32x20 mm

Suplying and fixing of PVC mini trunking on surface including changeable internal angles, external angles, flat anlges etc. complete as required- 32x12.5 mm

Suplying and fixing of PVC mini trunking on surface including changeable internal angles, external angles, flat anlges etc. complete as required- 32x16 mm

Page 157: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 158

Department of Engineering Services, MoWHS

Coefficient for per point of CD0320

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4860 PVC Boxes - 1 Module 1 each MT7000 Mini trunking 32x12.5mm 2 m MT7002 Changeable internal/external angle 1 each

MT7003 Changeable flat angle 1 eachMT7001 End cap 0.1 each

Coefficient for per point of CD0321

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.11 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.27 day MT4860 PVC Boxes - 1 Module 1 each MT7000 Mini trunking 32x12.5mm 5 m MT7002 Changeable internal/external angle 2 each

MT7003 Changeable flat angle 1 eachMT7001 End cap 0.2 each

Coefficient for per point of CD0322

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4860 PVC Boxes - 1 Module 1 each MT7000 Mini trunking 32x12.5mm 8.5 m MT7002 Changeable internal/external angle 2 each

MT7003 Changeable flat angle 1 eachMT7001 End cap 0.5 each

Coefficient for per point of CD0323

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.08 day LB0067 Painter Gd.2 0.06 day LB0069 Wireman Gd.2 0.203 day MT4863 PVC Boxes - 4 Module 1 each MT7000 Mini trunking 32x12.5mm 2 m MT7002 Changeable internal/external angle 1 each MT7003 Changeable flat angle 1 each

MT7001 End cap 0.1 each

CD0320Supplying and fixing of PVC mini trunking on surface for light/call bell/fan/2-pin socket outlet/3/5-pin 6A plug point along with all accessories such as changeable internal/external/flat anlges, flat junction,end caps, switch box etc. complete as required- Short Point

complete as required - Short Point

CD0321Supplying and fixing of PVC mini trunking on surface for light/call bell/fan/2-pin socket outlet/3/5-pin 6A plug point along with all accessories such as changeable internal/external/flat anlges, flat junction,end caps, switch box etc. complete as required- Medium Point

CD0322Supplying and fixing of PVC mini trunking on surface for light/call bell/fan/2-pin socket outlet/3/5-pin 6A plug point along with all accessories such as changeable internal/external/flat anlges, flat junction,end caps, switch box etc. complete as required- Long Point

CD0323Supplying and fixing of PVC mini-trunking on surface for 3/5 pin 6/16 ampere plug point along with all accessories such as changeable internal/external/flt angles, flat junctions, end caps, switch box, etc.

Page 158: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 159

Department of Engineering Services, MoWHS

Coefficient for per point of CD0324

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.11 day LB0067 Painter Gd.2 0.125 day LB0069 Wireman Gd.2 0.27 day MT4863 PVC Boxes - 4 Module 1 each MT7000 Mini trunking 32x12.5mm 5 m MT7002 Changeable internal/external angle 1 each MT7003 Changeable flat angle 1 each

MT7001 End cap 0.2 each

Coefficient for per point of CD0325

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.16 day LB0067 Painter Gd.2 0.2 day LB0069 Wireman Gd.2 0.36 day MT4863 PVC Boxes - 4 Module 1 each MT7000 Mini trunking 32x12.5mm 8.5 m MT7002 Changeable internal/external angle 1 each MT7003 Changeable flat angle 1 each

MT7001 End cap 0.5 each

CHAPTER 8: BOXES

BX0001 Coefficient for per each of BX0001

Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4905 Wooden boxes - Box 75x75x38mm 1 each BX0002 Coefficient for per each of BX0002

Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4909 Wooden boxes - Box 100x75x38mm 1 each

Supplying & fixing of wooden boxes including painting etc as required - 75x75x38mm

Supplying & fixing of wooden boxes including painting etc as required - 100x75x38mm

CD0324Supplying and fixing of PVC mini-trunking on surface for 3/5 pin 6/16 ampere plug point along with all accessories such as changeable internal/external/flt angles, flat junctions, end caps, switch box, etc. complete as required - Medium Point

CD0325Supplying and fixing of PVC mini-trunking on surface for 3/5 pin 6/16 ampere plug point along with all accessories such as changeable internal/external/flt angles, flat junctions, end caps, switch box, etc. complete as required - Long Point

Page 159: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 160

Department of Engineering Services, MoWHS

BX0003 Coefficient for per each of BX0003

Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4906 Wooden boxes - Box 100x100x38mm 1 each BX0004 Coefficient for per each of BX0004

Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4907 Wooden boxes - Box 150x150x38mm 1 each BX0005 Coefficient for per each of BX0005

Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4908 Wooden boxes - Box 180x150x38mm 1 each BX0006 Coefficient for per each of BX0006

Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4910 Wooden boxes - Box 200x100x38mm 1 each BX0007 Coefficient for per each of BX0007

Code Description Quant Units LB0051 Mason Gd.2 0.05 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.03125 day LB0069 Wireman Gd.2 0.0917 day MT4874 PVC sleev 35mm 4 each MT4911 Wooden boxes - Box 250x200x38mm 1 each

Supplying & fixing of wooden boxes including painting etc as required - 180x150x38mm

Supplying & fixing of wooden boxes including painting etc as required - 200x100x38mm

Supplying & fixing of wooden boxes including painting etc as required - 250x200x38mm

Supplying & fixing of wooden boxes including painting etc as required - 100x100x38mm

Supplying & fixing of wooden boxes including painting etc as required - 150x100x38mm

Page 160: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 161

Department of Engineering Services, MoWHS

BX0008

Coefficient for per each of BX0008

Code Description Quant Units LB0051 Mason Gd.2 0.05 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.03125 day LB0069 Wireman Gd.2 0.0917 day MT4874 PVC sleev 35mm 4 each MT4912 Wooden boxes - Box 300x200x38mm 1 each BX0009

Coefficient for per each of BX0009

Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.04175 day LB0069 Wireman Gd.2 0.1125 day MT4874 PVC sleev 35mm 6 each MT4913 Wooden boxes - Box 450x300x38mm 1 each

BX0020

Coefficient for per each of BX0020

Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4860 PVC Boxes - 1 Module 1 each MT4874 PVC sleev 35mm 4 each

BX0021

Coefficient for per each of BX0021

Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4861 PVC Boxes - 2 Module 1 each MT4874 PVC sleev 35mm 4 each

BX0022

Coefficient for per each of BX0022

Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4862 PVC Boxes - 3 Module 1 each MT4874 PVC sleev 35mm 4 each

Supplying & fixing of wooden boxes including painting etc as required - 300x200x38mm

Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required

Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required

Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required

Supplying & fixing of wooden boxes including painting etc as required - 450x300x38mm

Page 161: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 162

Department of Engineering Services, MoWHS

BX0023

Coefficient for per each of BX0023

Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4863 PVC Boxes - 4 Module 1 each

BX0024

Coefficient for per each of BX0024

Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4864 PVC Boxes - 5 Module 1 each

BX0025

Coefficient for per each of BX0025

Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4865 PVC Boxes - 6 Module 1 each

BX0026

Coefficient for per each of BX0026

Code Description Quant Units LB0051 Mason Gd.2 0.05 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.03125 day LB0069 Wireman Gd.2 0.0917 day MT4874 PVC sleev 35mm 4 each MT4866 PVC Boxes - 7 Module 1 each

BX0027

Coefficient for per each of BX0027

Code Description Quant Units LB0051 Mason Gd.2 0.05 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.03125 day LB0069 Wireman Gd.2 0.0917 day MT4874 PVC sleev 35mm 4 each MT4867 PVC Boxes - 8 Module 1 each

Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required

Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required

Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required

Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required

Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required

Page 162: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 163

Department of Engineering Services, MoWHS

BX0028

Coefficient for per each of BX0028

Code Description Quant Units LB0051 Mason Gd.2 0.0625 day LB0056 Wireman Gd.1 0.05 day LB0067 Painter Gd.2 0.04175 day LB0069 Wireman Gd.2 0.1125 day MT4874 PVC sleev 35mm 4 each MT4868 PVC Boxes - 9 Module 1 each

BX0029

Coefficient for per each of BX0029

Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT4869 PVC Boxes - 10 Module 1 each

BX0050

Coefficient for per each of BX0050

Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT5900 Metal boxes - 1 Module 1 each

BX0051

Coefficient for per each of BX0051

Code Description Quant Units LB0051 Mason Gd.2 0.0417 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.0833 day MT4874 PVC sleev 35mm 4 each MT5901 Metal boxes - 2 Module 1 each

BX0052

Coefficient for per each of BX0052

Code Description Quant Units LB0051 Mason Gd.2 0.0833 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.125 day MT4874 PVC sleev 35mm 4 each MT5902 Metal boxes - 3 Module 1 each

Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required

Supplying & fixing of PVC boxes for switch/socket outlet/switch socket combined/ gang switches on surface including painting etc as required

Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required

Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required

Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required

Page 163: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 164

Department of Engineering Services, MoWHS

BX0053

Coefficient for per each of BX0053

Code Description Quant Units LB0051 Mason Gd.2 0.0833 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.125 day MT4874 PVC sleev 35mm 4 each MT5903 Metal boxes - 4 Module 1 each

BX0054

Coefficient for per each of BX0054

Code Description Quant Units LB0051 Mason Gd.2 0.0833 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.125 day MT4874 PVC sleev 35mm 4 each MT5904 Metal boxes - 5 Module 1 each

BX0055

Coefficient for per each of BX0055

Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0125 day LB0069 Wireman Gd.2 0.1417 day MT4874 PVC sleev 35mm 4 each MT5905 Metal boxes - 6 Module 1 each

BX0056

Coefficient for per each of BX0056

Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0156 day LB0069 Wireman Gd.2 0.1417 day MT4874 PVC sleev 35mm 4 each MT5906 Metal boxes - 7 Module 1 each

BX0057

Coefficient for per each of BX0057

Code Description Quant Units LB0051 Mason Gd.2 0.1 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0156 day

Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required

Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required

Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required

Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required

Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required

Page 164: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 165

Department of Engineering Services, MoWHS

LB0069 Wireman Gd.2 0.1417 day MT4874 PVC sleev 35mm 4 each MT5907 Metal boxes - 8 Module 1 each

BX0058

Coefficient for per each of BX0058

Code Description Quant Units LB0051 Mason Gd.2 0.0833 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.125 day MT4874 PVC sleev 35mm 4 each MT5908 Metal boxes - 9 Module 1 each

BX0059

Coefficient for per each of BX0059

Code Description Quant Units LB0051 Mason Gd.2 0.0833 day LB0056 Wireman Gd.1 0.0417 day LB0067 Painter Gd.2 0.0104 day LB0069 Wireman Gd.2 0.125 day MT4874 PVC sleev 35mm 4 each MT5909 Metal boxes - 10 Module 1 each

CHAPTER 9: SWITCHES & SOCKETS

SS0001

Coefficient for per each of SS0001

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

SS0002

Coefficient for per each of SS0002

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each

SS0003

Coefficient for per each of SS0003

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5821 Bell push 6A 1 each MT5822 Plate 1-module with frame 1 each

SS0015

Coefficient for per each of SS0015

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day

Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required

Supplying & fixing of 6A switch on existing wooden board including necessary cutting, connections, testing etc. as required. - 6A switch SP 1- way

Supplying & fixing of 6A switch on existing wooden board including necessary cutting, connections, testing etc. as required. - 6A switch SP 2- way

Supplying & fixing of 6A switch on existing wooden board including necessary cutting, connections, testing etc. as required. - bell push 6A

Supplying & fixing of socket/regulator on existing wooden board including necessary cutting, connections, testing etc. as required. - Regulator or Dimmer

Supplying & fixing of metal boxes for switch/socket outlet/switch socket combined/ gang switches on surface or recessed including painting etc as required

Page 165: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 166

Department of Engineering Services, MoWHS

LB0069 Wireman Gd.2 0.0417 day MT5817 Dimmer / regulator 1 each MT5823 Plate 2-module with frame 1 each

SS0016

Coefficient for per each of SS0016

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5820 RJ 11 telephone socket 1 each MT5822 Plate 1-module with frame 1 each

Supplying & fixing of socket/regulator on existing wooden board including necessary cutting, connections, testing etc. as required. - RJ 11Telephone socket

Page 166: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 167

Department of Engineering Services, MoWHS

SS0017

Coefficient for per each of SS0017

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5818 TV coaxial socket 1 each MT5822 Plate 1-module with frame 1 each

SS0030

Coefficient for per each of SS0030

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5808 2-pin 6A socket outlet 1 each MT5822 Plate 1-module with frame 1 each

SS0031

Coefficient for per each of SS0031

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5816 5-pin universal socket outlet 1 each MT5823 Plate 2-module with frame 1 each

SS0032

Coefficient for per each of SS0032

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5807 16A fuse unit 1 each MT5822 Plate 1-module with frame 1 each

SS0045

Coefficient for per each of SS0045

Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5806 16A switch SP 1 or 2-way 1 each MT5822 Plate 1-module with frame 1 each

Supplying & fixing of socket/regulator on existing wooden board including necessary cutting, connections, testing etc. as required. - TV coaxial socket

Supplying & fixing of socket outlet on existing wooden board including necessary cutting, connections, testing etc. as required. - 2 pin 6A socket outlet

Supplying & fixing of socket outlet on existing wooden board including necessary cutting, connections, testing etc. as required. - 5 pin universal socket outlet

Supplying & fixing of socket outlet on existing wooden board including necessary cutting, connections, testing etc. as required. - 16 ampere fuse unit

Supplying & fixing of switch on existing wooden board/round block/junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. - 16A switch SP 1 or 2 way

Page 167: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 168

Department of Engineering Services, MoWHS

SS0046

Coefficient for per each of SS0046

Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5814 5/6 pin, 6/16A socket outlet, shuttered 1 each MT5825 Plate 4-module with frame 1 each

SS0047

Coefficient for per each of SS0047

Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5895 Ceiling Rose, 2 plate (PVC) 6A 1 each

SS0060

Coefficient for per each of SS0060

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

SS0061

Coefficient for per each of SS0061

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each

SS0062

Coefficient for per each of SS0062

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5821 Bell push 6A 1 each MT5822 Plate 1-module with frame 1 each

SS0075

Coefficient for per each of SS0075

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5817 Dimmer / regulator 1 each MT5823 Plate 2-module with frame 1 each

Supplying & fixing of socket on existing wooden board/round block/junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. - 5/6 pin, 6/16 ampere socket outlet, shuttered

Supplying & fixing of ceiling rose on existing wooden board/round block/junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. -Ceiling rose, 2 plate (PVC) 6A

Supplying & fixing of 6A switch on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - 6A switch SP 1 way

Supplying & fixing of 6A switch on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - 6A switch SP 2 way

Supplying & fixing of 6A switch on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - bell push 6A

Supplying & fixing of socket/regulator on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - Regulator or Dimmer

Page 168: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 169

Department of Engineering Services, MoWHS

SS0076

Coefficient for per each of SS0076

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5820 RJ 11 telephone socket 1 each MT5822 Plate 1-module with frame 1 each

SS0077

Coefficient for per each of SS0077

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5818 TV coaxial socket 1 each MT5822 Plate 1-module with frame 1 each

SS0090

Coefficient for per each of SS0090

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5808 2-pin 6A socket outlet 1 each MT5822 Plate 1-module with frame 1 each

SS0091

Coefficient for per each of SS0091

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5816 5-pin universal socket outlet 1 each MT5823 Plate 2-module with frame 1 each

SS0092

Coefficient for per each of SS0092

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5807 16A fuse unit 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per each of SS0105

Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5806 16A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each

16A switch SP 2 way SS0105

Supplying & fixing of socket/regulator on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - RJ 11 Telephone socket

Supplying & fixing of socket/regulator on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - TV coaxial socket

Supplying & fixing of socket outlet on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - 2- pin 6A socket outlet

Supplying & fixing of socket outlet on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - 5 pin universal socket outlet

Supplying & fixing of socket outlet on existing metal box with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - 16A fuse unit

Supplying & fixing of switch on existing metal box with fibre sheet cover (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connection testing etc. as required-

Page 169: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 170

Department of Engineering Services, MoWHS

Coefficient for per each of SS0106

Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5814 5/6 pin, 6/16A socket outlet, shuttered 1 each MT5825 Plate 4-module with frame 1 each

Coefficient for per each of SS0107

Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5895 Ceiling Rose, 2 plate (PVC) 6A 1 each

SS0120

Coefficient for per each of SS0120

Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5800 6A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

SS0121

Coefficient for per each of SS0121

Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5802 6A switch SP 2-way 1 each MT5822 Plate 1-module with frame 1 each

SS0122

Coefficient for per each of SS0122

Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5821 Bell push 6A 1 each MT5822 Plate 1-module with frame 1 each

SS0135

Coefficient for per each of SS0135

Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5817 Dimmer / regulator 1 each MT5823 Plate 2-module with frame 1 each

Ceiling rose, 2 plate (PVC) 6A SS0107

Supplying & fixing of 6A switch on existing PVC/metal / moulded tough surface box (recessed or surface) including necessary cutting, connections, testing etc. as required. - 6A switch SP 1 way

Supplying & fixing of 6A switch on existing PVC/metal / moulded tough surface box (recessed or surface) including necessary cutting, connections, testing etc. as required. - 6A switch SP 2 way

Supplying & fixing of 6A switch on existing PVC/metal / moulded tough surface box (recessed or surface) including necessary cutting, connections, testing etc. as required. - bell push 6A

Supplying & fixing of socket/regulator on existing PVC/metal / moulded tough surface box (recessed or surface) including necessary cutting, connections, testing etc. as required. - Regulator or Dimmer

Supplying & fixing of socket on existing metal box with fibre sheet cover (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connection testing etc. as required. - 5/6 pin 6/16A socket outlet, shuttered

SS0106

Supplying & fixing of ceiling rose on existing metal box with fibre sheet cover (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. -

Page 170: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 171

Department of Engineering Services, MoWHS

SS0136

Coefficient for per each of SS0136

Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5820 RJ 11 telephone Socket 1 each MT5822 Plate 1-module with frame 1 each

SS0137

Coefficient for per each of SS0137

Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5818 TV coaxial socket 1 each MT5822 Plate 1-module with frame 1 each

SS0150

Coefficient for per each of SS0150

Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5808 2-pin 6A socket outlet 1 each MT5822 Plate 1-module with frame 1 each

SS0151

Coefficient for per each of SS0151

Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5816 5-pin universal socket outlet 1 each MT5823 Plate 2-module with frame 1 each

SS0152

Coefficient for per each of SS0152

Code Description Quant Units LB0056 Wireman Gd.1 0.0333 day LB0069 Wireman Gd.2 0.0333 day MT5807 16A fuse unit 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per each of SS0165

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5806 16A switch SP 1 or 2-way 1 each MT5822 Plate 1-module with frame 1 each

Supplying & fixing of switch on existing metal box with fibre sheet cover (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. - 16A switch SP 2 way

SS0165

Supplying & fixing of socket/regulator on existing PVC/metal / moulded tough surface box (recessed or surface) including necessary cutting, connections, testing etc. as required. - RJ 11 telephone socket

Supplying & fixing of socket/regulator on existing PVC/metal / moulded tough surface box (recessed or surface) including necessary cutting, connections, testing etc. as required. - TV coaxial socket

Supplying & fixing of socket outlet on existing PVC/metal / moulded tough surface box (recessed or surface)including necessary cutting, connections, testing etc. as required. - 2 pin 6A socket outlet

Supplying & fixing of socket outlet on existing PVC/metal / moulded tough surface box (recessed or surface) including necessary cutting, connections, testing etc. as required. - 5 pin universal socket outlet

Supplying & fixing of socket outlet on existing PVC/metal / moulded tough surface box (recessed or surface) including necessary cutting, connections, testing etc. as required. - 16A fuse unit

Page 171: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 172

Department of Engineering Services, MoWHS

Coefficient for per each of SS0166

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5814 5/6 pin, 6/16A socket outlet, shuttered 1 each MT5825 Plate 4-module with frame 1 each

Coefficient for per each of SS0167

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5895 Ceiling Rose, 2 plate (PVC) 6A 1 each

Coefficient for per each of SS0175

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5809 3-Pin, 6A socket outlet, shuttered 1 each MT5824 Plate 3-module with frame 1 each

Coefficient for per each of SS0176

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5816 5-pin universal socket outlet 1 each MT5823 Plate 2-module with frame 1 each

Coefficient for per each of SS0177

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5819 RJ 45 computer socket 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per each of SS0185

Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5804 16A switch SP 1-way 1 each MT5822 Plate 1-module with frame 1 each

Supplying & fixing of switch on existing PVC /metal/ moulded tough surface box, metal box (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. - 16A switch SP 1 way

SS0185

Supplying & fixing of socket outlet on existing PVC /metal/ moulded tough surface box/ metal box (recessed or surface) including necessary cutting, connections, testing etc. as required. - 5 pin universal socket outlet

SS0176

Supplying & fixing of socket outlet on existing PVC /metal/ moulded tough surface box/ metal box (recessed or surface) including necessary cutting, connections, testing etc. as required. - RJ 45 compter socket

SS0177

Supplying & fixing of Ceiling rose on existing metal box with fibre sheet cover (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. -Ceiling rose, 2 plate(PVC) 6A

SS0167

Supplying & fixing of socket outlet on existing PVC /metal/ moulded tough surface box/ metal box (recessed or surface) including necessary cutting, connections, testing etc. as required. - 3 pin, 6A socket outlet, shuttered

SS0175

Supplying & fixing of socket on existing metal box with fibre sheet cover (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. - 5/6 pin 6/16A socket outlet, shuttered

SS0166

Page 172: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 173

Department of Engineering Services, MoWHS

Coefficient for per each of SS0186

Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5806 16A switch SP 2 way 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per each of SS0187

Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day MT5814 5/6 pin, 6/16A socket outlet, shuttered 1 each MT5825 Plate 4-module with frame 1 each

Coefficient for per each of SS0195

Code Description Quant Units LB0056 Wireman Gd.1 0.0417 day LB0069 Wireman Gd.2 0.0417 day MT5810 3-pin, 16A socket outlet, shuttered 1 each MT5822 Plate 1-module with frame 1 each

Coefficient for per each of SS0205

Code Description Quant Units LB0056 Wireman Gd.1 0.0555 day LB0069 Wireman Gd.2 0.0555 day MT5811 3-pin, 6A switch/socket combined, shuttered 1 each MT5824 Plate 3-module with frame 1 each

Coefficient for per each of SS0210

Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0069 Wireman Gd.2 0.0625 day MT5813 3-pin, 16A switch/socket combined, Shuttered 1 each MT5825 Plate 4-module with frame 1 each

Supplying & fixing of 6 ampere switch/socket on existing PVC /metal/ moulded tough surface box metal box (recessed or surface) with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - 3 pin 6 ampere switch/socket combined, shuttered

SS0205

Supplying & fixing of switch/socket on existing PVC /metal/ moulded tough surface box metal box (recessed or surface) with fibre sheet cover (recessed or surface) including necessary cutting, connections, testing etc. as required. - 3 pin, 16A switch/socket combined, shuttered

SS0210

Supplying & fixing of socket on existing PVC /metal/ moulded tough surface box, metal box (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. - 5/6 pin, 6/16A socket outlet, shuttered

SS0187

Supplying & fixing of 16A switch on existing PVC /metal/ moulded tough surface box metal box (recessed or surface) with fibre sheet cover (recessed or surface) including necessary cutting, connection testing etc. as required- 3 pin 16 ampere socket outlet

SS0195

Supplying & fixing of switch on existing PVC /metal/ moulded tough surface box, metal box (recessed or surface)/ junction box (PVC/metal) including necessary cutting, connections, testing etc. as required. - 16A switch SP 2way

SS0186

Page 173: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 174

Department of Engineering Services, MoWHS

Coefficient for per each of SS0220

Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0069 Wireman Gd.2 0.0625 day MT5815 5/6 pin, 6/16A switch/socket combined, shuttered 1 each MT5825 Plate 4-module with frame 1 each

Coefficient for per each of SS0221

Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0069 Wireman Gd.2 0.0625 day MT5890 Holders & Plugs - Batten holder (heavy duty, brass) 1 each

Coefficient for per each of SS0230

Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0069 Wireman Gd.2 0.0625 day MT5891 Holders & Plugs - Plain pendant holder (bakelite) 1 each

Coefficient for per each of SS0231

Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0069 Wireman Gd.2 0.0625 day MT5891 Holders & Plugs - Plain pendant holder (bakelite) 1 each

Coefficient for per each of SS0232

Code Description Quant Units LB0056 Wireman Gd.1 0.0625 day LB0069 Wireman Gd.2 0.0625 day MT5892 Holders & Plugs - Angle holder (heavy duty) 1 each

CHAPTER 10: INDOOR LUMINIARIES (Supply)

Coefficient for per each of IL0001

Code Description Quant Units MT5720 Globe dia 150mm, 1x60W 1 each

Supplying & fixing on existing PVC/ wooden /metal/ moulded tough surface box with fibre sheet cover, round block, junction box (recessed or surface) including necessary cutting, connections, testing etc.as required. - Angle holder (heavy duty, brass plunger)

SS0232

Supplying & fixing on existing PVC/ wooden /metal/ moulded tough surface box with fibre sheet cover, round block, junction box (recessed or surface) including necessary cutting, connections, testing etc. as required. - Plain pendant holder with alumetic 2 core PVC wire cord grip

SS0230

Supplying & fixing on existing PVC/ wooden /metal/ moulded tough surface box with fibre sheet cover, round block, junction box (recessed or surface) including necessary cutting, connection testing etc.as required. - Plain pendant brass holder (heavy duty with twin twisted flexible wire)

SS0231

Supplying & fixing of switch/socket on existing PVC/ wooden /metal/ moulded tough surface box with fibre sheet cover, round block, junction box (recessed or surface) including necessary cutting, connections, testing etc. as required. - 5/6 pin, switch / socket combined, shuttered

SS0220

Supplying & fixing on existing PVC/ wooden /metal/ moulded tough surface box with fibre sheet cover, round block, junction box (recessed or surface) including necessary cutting, connections testing etc. as required. - Batten holder (heavy duty, brass plunger)

SS0221

Supplying of prewired indoor surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. butwithout lamp - Globe dia 150, projection 215mm, finish-painted

IL0001

Page 174: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 175

Department of Engineering Services, MoWHS

Coefficient for per each of IL0002

Code Description Quant Units MT5721 Globe dia 200mm, 1x60W 1 each

Coefficient for per each of IL0003

Code Description Quant Units MT5722 Globe dia 250mm, 1x60W 1 each

Coefficient for per each of IL0004

Code Description Quant Units MT5723 Square louvered, 1x60W 1 each

Coefficient for per each of IL0005

Code Description Quant Units MT5724 Special drumlite, dia 175mm milky, 1x60W 1 each

Coefficient for per each of IL0006

Code Description Quant Units MT5725 Special drumlite dia 225mm milky, 1x60W 1 each

Coefficient for per each of IL0020

Code Description Quant Units MT5726 Spot light 235mm, reflector dia 130mm, 1x60W 1 each

Coefficient for per each of IL0021

Code Description Quant Units MT5727 Spot light 245mm, reflector dia 100mm, 1x60W 1 each

Supplying of prewired indoor surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. but without lamp - Square louvered, projection 115mm, length or width 240mm,finish-painted

Supplying of prewired indoor surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. but without lamp - Globe dia 200, projection 265mm, finish-painted

IL0002

Supplying of prewired indoor surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. but without lamp - Globe dia 250, projection 315mm, finish-painted

IL0003

IL0004

Supplying of prewired indoor surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. but without lamp - Special drumlite dia 175, projection 115mm, finish-painted

IL0005

Supplying of prewired indoor surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. but without lamp - Special drumlite dia 225, milky, projection 115mm, finish-painted

IL0006

Supplying of prewired indoor spots and clamps surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. but without lamp - Spot light fixtures finish-painted, reflector dia 130mm, projection 235mm

IL0020

Supplying of prewired indoor spots and clamps surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. but without lamp - Spot light fixtures, finish-painted, reflector dia 100mm, projection 245mm

IL0021

Page 175: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 176

Department of Engineering Services, MoWHS

Coefficient for per each of IL0022

Code Description Quant Units MT5728 Clamp light 225mm, dia 110mm, 1x60W 1 each

Coefficient for per each of IL0035

Code Description Quant Units MT5729 Clamp light 160mm, 100W 1 each

Coefficient for per each of IL0036

Code Description Quant Units MT5730 Rail light 225mm, 2x60W (R) 1 each

Coefficient for per each of IL0037

Code Description Quant Units MT5731 Rail light 160mm, 2x100W (R) 1 each

Coefficient for per each of IL0050

Code Description Quant Units MT5732 Rail light 225mm, 3x60W (R) 1 each

Coefficient for per each of IL0051

Code Description Quant Units MT5733 Rail light 160mm, 3x100W (R) 1 each

Coefficient for per each of IL0052

Code Description Quant Units MT5734 Wall bracket 225mm, 1x60W 1 each

Coefficient for per each of IL0065

Code Description Quant Units MT5735 Wall bracket 230mm, 1x60W 1 each

Supplying of prewired indoor spots and clamps surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, glass globe etc. but without lamp-Clamp light fixtures, reflector dia 110mm, projection 225mm, finish-painted

IL0022

Supplying of prewired indoor clamps and rails on surface / ceiling mounted luminiaries suitable for reflector lamp for maximum wattage upto 60/100 watts complete with all accessories such as base,holder, reflector etc. but without lamp - Clamp light projection 160mm, finish-painted, suitable for reflector lamp, 100W

IL0035

Supplying of prewired indoor clamps and rails on surface / ceiling mounted luminiaries suitable for reflector lamp for maximum wattage upto 60/100 watts complete with all accessories such as base, holder, reflector etc. but without lamp - Rail light fixtures for 2x60W (R), reflector lamp of projection 225mm, rail lenght 600mm

IL0036

Supplying of prewired indoor rails and wall brackets on surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base,

Supplying of prewired indoor clamps and rails on surface / ceiling mounted luminiaries suitable for reflector lamp for maximum wattage upto 60/100 watts complete with all accessories such as base, holder, reflector etc. but without lamp - Rail light lamp of projection 160mm, rail length 600mm, 2x100W (R)

IL0037

Supplying of prewired indoor rails and wall brackets on surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, reflector, rails, glass globe, etc. but without lamp - Rail lighting projection 225mm, finish painted, suitable for reflector lamp, 3x60W (R)

IL0050

holder, reflector, rails, glass globe, etc. but without lamp - Rail lighting fixtures of projection 160mm for 3x100W (R) reflector lamp length of rail 600mm

IL0051

Supplying of prewired indoor rails and wall brackets on surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, reflector, rails, glass globe, etc. but without lamp - Wall bracket projection 225mm, height 240mm finish painted, glass frosted, 1x60W

IL0052

Supplying of prewired indoor rails and wall brackets on surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, reflector, rails, glass globe, etc. but without lamp - Wall bracket upward projection 230mm, height 225mm finish-painted globe 360/400mm dia.. glass milky/ frosted, 1x60W

IL0065

Page 176: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 177

Department of Engineering Services, MoWHS

Coefficient for per each of IL0066

Code Description Quant Units MT5736 Wall bracket 160mm, 1x60W 1 each

Coefficient for per each of IL0067

Code Description Quant Units MT5737 Wall bracket 185mm, 1x60W 1 each

Coefficient for per each of IL0080

Code Description Quant Units MT5738 Double wall bracket 200mm, 2x60W 1 each

Coefficient for per each of IL0081

Code Description Quant Units MT5739 Double wall bracket 160mm, 2x60W 1 each

Coefficient for per each of IL0082

Code Description Quant Units MT5740 Single swivel wall bracket 375mm, 1x60W 1 each

Coefficient for per each of IL0095

Code Description Quant Units MT5741 Double mirror light 610mm, 2x60W 1 each

Coefficient for per each of IL0096

Code Description Quant Units MT5742 Double mirror light 460mm, 2x60W 1 each

Coefficient for per each of IL0097

Code Description Quant Units MT5743 Single picture light 200mm, 1x60W 1 each

Supplying of prewired indoor rails and wall brackets on surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, reflector, rails, glass globe, etc. but without lamp - Wall bracket down lighter projection 160mm, height 135mm width or base dia 320mm finish-painted, glass frosted, 1x60W

IL0066

Supplying of prewired indoor rails and wall brackets on surface / ceiling mounted luminiaries suitable for GLS lamp for maximum wattage upto 1x60 watts complete with all accessories such as base, holder, reflector, rails, glass globe, etc. but without lamp - Wall bracket down lighter, projection 185mm, height 100mm finish painted, 1x60W

IL0067

without lamp - Double wall bracket upward projection 200mm, height 275mm finish-painted globe 360/400mm dia.. glass milky/ frosted, 2x60W

Supplying of prewired indoor wall mounted wall brackets luminiaries suitable for GLS lamp for wattage upto 2x60/1x60 watts complete with all accessories such as base, holder, glass globe, etc. but IL0080

Supplying of prewired indoor wall mounted wall brackets luminiaries suitable for GLS lamp for wattage upto 2x60/1x60 watts complete with all accessories such as base, holder, glass globe, etc. but withoutlamp - Double wall bracket down lighter projection 160mm, height 135mm width or base dia 320mm finish-painted, glass frosted, 2x60W

IL0081

Supplying of prewired indoor wall mounted wall brackets luminiaries suitable for GLS lamp for wattage upto 2x60/1x60 watts complete with all accessories such as base, holder, glass globe, etc. but without lamp - Single swivel wall bracket down lighter, projection 375mm, height 250mm finish painted with switch, 1x60W

IL0082

Supplying of prewired indoor mirror/picture light luminiaries suitable for GLS lamp for wattage upto 2x60/1x60 watts complete with all accessories such as base, holder, glass globe, etc. but without lamp-Double mirror light fixtures downward projection 100mm, height 90mm, lenght 610mm, finish-painted, glass milky/ frosted, 2x60W

IL0095

Supplying of prewired indoor mirror/picture light luminiaries suitable for GLS lamp for wattage upto 2x60/1x60 watts complete with all accessories such as base, holder, glass globe, etc. but without lamp - Double mirror light fixtures downward projection 100mm, height 90mm, lenght 460mm, finish-painted, glass milky/ frosted, 2x60W

IL0096

Supplying of prewired indoor mirror/picture light luminiaries suitable for GLS lamp for wattage upto 2x60/1x60 watts complete with all accessories such as base, holder, glass globe, etc. but without lamp - Single picture down lighter, projection 200mm, height 100mm, length 360mm, finish painted, 1x60W

IL0097

Page 177: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 178

Department of Engineering Services, MoWHS

Coefficient for per each of IL0110

Code Description Quant Units MT5744 Pendant down lighter 215mm, 1x60W 1 each

Coefficient for per each of IL0111

Code Description Quant Units MT5745 Pendant lantern type 460mm, 1x60W 1 each

Coefficient for per each of IL0112

Code Description Quant Units MT5746 Pendant 460mm, 3x60W 1 each

Coefficient for per each of IL0125

Code Description Quant Units MT5747 Recessed down lighter square 170-190mm, 1x100W 1 each

Coefficient for per each of IL0126

Code Description Quant Units MT5748 Recessed down lighter, round 180mm, 1x100W 1 each

Coefficient for per each of IL0127

Code Description Quant Units MT5749 Recessed down lighter, round 165mm, 1x60W (R) 1 each

Coefficient for per each of IL0140

Code Description Quant Units MT5750 Semi recessed down lighter square 170-200mm, 1x100W 1 each

Coefficient for per each of IL0141

Code Description Quant Units MT5751 Semi recessed down lighter, round 90-95mm, 1x100W 1 each

Supplying of prewired indoor pendant lighting luminiaries suitable for GLS lamp 1x60 watts complete with all accessories such as base, holder, glass globe, reflector, suspender, etc etc. but without lamp - Pendant down lighter height 215mm, 205mm dia, finish-painted, 1x60W

IL0110

Supplying of prewired indoor pendant lighting luminiaries suitable for GLS lamp 1x60 watts complete with all accessories such as base, holder, glass globe, reflector, suspender, etc etc. but without lamp - Lantern type, height 460mm, 325mm dia, finish-painted, 1x60W

IL0111

Supplying of prewired indoor pendant lighting luminiaries suitable for GLS lamp 1x60 watts complete with all accessories such as base, holder, glass globe, reflector, suspender, etc etc. but without lamp - Three lighting fixture, height 460mm, 430mm dia finish painted, 3x60W

IL0112

Supplying of prewired indoor recessed down light luminiaries suitable for GLS/reflector lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass globe, reflector, fixingclip, etc etc. but without lamp - Recessed down lighter square width 170-195, cut out 140-165mm, depth 200mm, finish-painted, 1x100W

IL0125

Supplying of prewired indoor recessed down light luminiaries suitable for GLS/reflector lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass globe, reflector, fixing clip, etc etc. but without lamp - Recessed down lighter projection 55mm, cut out 155mm, depth 175mm, 180mm dia, finish-painted, 1x100W

IL0126

Supplying of prewired indoor recessed down light luminiaries suitable for GLS/reflector lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass globe, reflector, fixing clip, etc etc. but without lamp - Recessed down lighter projection 45mm, cut out 110mm, depth 75mm, 165mm dia, finish-painted, 1x60W

IL0127

Supplying of prewired indoor semi-recessed down light luminiaries suitable for GLS/reflector lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass globe, reflector, fixing clip, etc etc. but without lamp - Semi recessed down lighter square width 170-200, cut out 135-160mm, depth 125-135mm, finish-painted, 1x100W

IL0140

Supplying of prewired indoor semi-recessed down light luminiaries suitable for GLS/reflector lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass globe, reflector, fixing clip, etc etc. but without lamp - Semi recessed down lighter projection 90-95mm, cut out 135-160mm, depth 125-135mm, 170-200mm dia, finish-painted, 1x100W

IL0141

Page 178: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 179

Department of Engineering Services, MoWHS

Coefficient for per each of IL0142

Code Description Quant Units MT5752 Semi recessed down lighter, side entry 205mm, 1x60W (R) 1 each

Coefficient for per each of IL0155

Code Description Quant Units

MT5945Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Strip Rail, 18/20 W, LPF 1 each

Coefficient for per each of IL0156

Code Description Quant Units

MT5946Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Decorative, box type 18/20 W, LPF 1 each

Coefficient for per each of IL0157

Code Description Quant Units

MT5947Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Mounting channel, 18/20 W, LPF 1 each

Coefficient for per each of IL0158

Code Description Quant Units

MT5948Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Strip Rail, 36/40 W, LPF 1 each

Coefficient for per each of IL0159

Code Description Quant Units

MT5949Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Decorative, box type 36/40 W, LPF 1 each

Coefficient for per each of IL0160

Code Description Quant Units

MT5950Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Mounting channel, 36/40 W, LPF 1 each

Coefficient for per each of IL0170

Code Description Quant Units

MT5951Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Mounting box, 1x36/40 W, HPF 1 each

Supplying of prewired indoor semi-recessed down light luminiaries suitable for GLS/reflector lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass globe, reflector, fixing clip, etc etc. but without lamp - Semi recessed down lighter side entry, cut out 185mm, depth 130mm, 205mm dia, finish-painted, 1x60W

IL0142

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, LPF suitable for wall and ceiling - Strip Rail 18/20 watt

IL0155

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, LPF suitable for wall and ceiling - Decorative box type 18/20 watt

IL0156

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, LPF suitable for wall and ceiling - Mounting channel 18/20 watt

IL0157

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, LPF suitable for wall and ceiling - Strip Rail 36/40 watt

IL0158

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, LPF suitable for wall and ceiling - Decorative box type 36/40 watt

IL0159

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, LPF suitable for wall and ceiling - Mounting channel 36/40 watt

IL0160

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for wall and ceiling directly or pendant - Mounting box 1x36/40 watt

IL0170

Page 179: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 180

Department of Engineering Services, MoWHS

Coefficient for per each of IL0171

Code Description Quant Units

MT5952Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Mounting box, 2x36/40 W, HPF 1 each

Coefficient for per each of IL0172

Code Description Quant Units

MT5953Prewired Indoor fluorescent lamp luminiaries (CRCA sheet housing, steel) for wall/ceiling - Industrial box, 1x36/40 W, HPF 1 each

Coefficient for per each of IL0173

Code Description Quant Units

MT5970Indoor fluorescent lamp luminiaries, steel rail, Industrial box - Vitreous enamel reflector, 1x36/40 W, HPF 1 each

Coefficient for per each of IL0174

Code Description Quant Units

MT5971Indoor fluorescent lamp luminiaries, steel rail, Industrial box - Stove enamel reflector, 2x36/40 W, HPF 1 each

Coefficient for per each of IL0175

Code Description Quant Units

MT5973Indoor fluorescent lamp luminiaries, steel rail, Industrial box - Vitreous enamel reflector, 2x36/40 W, HPF 1 each

Coefficient for per each of IL0185

Code Description Quant Units

MT5990

Indoor decorative fluorescent lamp luminiaries, steel rail, surface mounting box - Polysterene structured louvere and reflector, 2x36/40 W, HPF 1 each

Coefficient for per each of IL0186

Code Description Quant Units

MT5991Indoor decorative fluorescent lamp luminiaries, steel rail, surface mounting box - Metal louvere and reflector, 2x36/40 W, HPF 1 each

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for wall and ceiling directly or pendant - Mounting box 2x36/40 watt

IL0171

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for wall and ceiling directly or pendant - Industrial box 1x36/40 watt

IL0172

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for wall and ceiling directly or pendant - Industrial box type with vitreous enamel reflector 1x36/40 watt

IL0173

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for wall and ceiling directly or pendant - Industrial box type with vitreous enamel reflector 2x36/40 watt

IL0174

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for wall and ceiling directly or pendant - Industrial box type with stove enamel reflector 2x36/40 watt

IL0175

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface or pendant mounting - Mounting box type with polysterene structured louvere and reflector 2x36/40 watt

IL0185

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface or pendant mounting - Mounting box type with metalled louvere and reflector 2x36/40 watt

IL0186

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface or pendant mounting - Mounting box type with opal acrylic difuser and reflector 2x36/40 watt

IL0187

Page 180: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 181

Department of Engineering Services, MoWHS

Code Description Quant Units

MT5992Indoor decorative fluorescent lamp luminiaries, steel rail, surface mounting box - Opal acrylic diffuser and reflector, 2x36/40 W, HPF 1 each

Coefficient for per each of IL0188

Code Description Quant Units

MT5994Indoor decorative fluorescent lamp luminiaries, steel rail, surface mounting box - Prismatic louvere and reflector, 2x36/40 W, HPF 1 each

Coefficient for per each of IL0189

Code Description Quant Units

MT5995Indoor decorative fluorescent lamp luminiaries, steel rail, surface mounting box - Opal acrylic diffuser, 2x36/40 W, HPF 1 each

Coefficient for per each of IL0190

Code Description Quant Units

MT5996Indoor decorative fluorescent lamp luminiaries, steel rail, surface mounting box - Opal acrylic diffuser and reflector, 2x18/20 W, HPF 1 each

Coefficient for per each of IL0200

Code Description Quant Units

MT6020Indoor decorative fluorescent lamp luminiaries, steel rail, recessed, Mounting box - Prismatic louvere and reflector, 2x36/40 W, HPF 1 each

Coefficient for per each of IL0201

Code Description Quant Units

MT6021Indoor decorative fluorescent lamp luminiaries, steel rail, recessed, Mounting box - Opal acrylic diffuser, 2x36/40 W, HPF 1 each

Coefficient for per each of IL0202

Code Description Quant Units

MT6022Indoor decorative fluorescent lamp luminiaries, steel rail, recessed, Mounting box - Structured louvere and reflector, 2x36/40 W, HPF 1 each

Coefficient for per each of IL0215

Code Description Quant Units

MT6040Indoor decorative fluorescent lamp luminiaries, steel rail, surface/recessed, Mounting box - Prismatic louvere and reflector, 4x18/20 W, HPF 1 each

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface or pendant mounting - Mounting box type with prismatic louvere and reflector 2x36/40 watt

IL0188

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface or pendant mounting - Mounting box type with opal acrylic difuser 1x36/40 watt

IL0189

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface or pendant mounting - Mounting box type with opal acrylic difuser and reflector 2x18/20 watt

IL0190

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for recessed mounting - Mounting box type with prismatic louvere and reflector 2x36/40 watt

IL0200

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for recessed mounting - Mounting box type with opal acrylic difuser 1x36/40 watt

IL0201

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for recessed mounting - Mounting box type with structured louvere and reflector 2x36/40 watt

IL0202

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface/recessed mounting - Mounting box type with prismatic louvere and reflector 4x18/20 watt

IL0215

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface/recessed mounting - Mounting box type with opal acrylic difuser 4x18/20 watt

IL0216

Page 181: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 182

Department of Engineering Services, MoWHS

Coefficient for per each of IL0216

Code Description Quant Units

MT6041

Indoor decorative fluorescent lamp luminiaries, steel rail, surface/recessed, Mounting box - Opal acrylic diffuser, 4x18/20 W, HPF 1 each

Coefficient for per each of IL0217

Code Description Quant Units

MT6042Indoor decorative fluorescent lamp luminiaries, steel rail, surface/recessed, Mounting box - Structured louvere and reflector, 4x18/20 W, HPF 1 each

Coefficient for per each of IL0230

Code Description Quant Units

MT6043Indoor decorative fluorescent lamp luminiaries, steel rail, surface/recessed, Mounting box - Mirror Optic louvere and reflector, 2x18/20 W, HPF 1 each

Coefficient for per each of IL0231

Code Description Quant Units

MT6044Indoor decorative fluorescent lamp luminiaries, steel rail, surface/recessed, Mounting box - Mirror optic louvere, 2x36/40 W, HPF 1 each

Coefficient for per each of IL0232

Code Description Quant Units

MT6045Indoor decorative fluorescent lamp luminiaries, steel rail, surface/recessed, Mounting box - Wide spread mirror optic and reflector, 2x36/40 W, HPF 1 each

IL0245

Coefficient for per each of IL0245

Code Description Quant Units MT6190 Call bell 250 volt A.C - Gong bell assembly 1 each

IL0246

Coefficient for per each of IL0246

Code Description Quant Units MT6191 Call bell 250 volt A.C - Buzzer bell assembly 1 each

IL0247

Coefficient for per each of IL0247

Code Description Quant Units MT6192 Call bell 250 volt A.C - Musical bell assembly 1 each

Coefficient for per each of IL0260

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface/recessed mounting - Mounting box type with structured louvere and reflector 4x18/20 watt

IL0217

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface/recessed mounting - Mounting box with mirror optics louvere and reflector 2x18/20 watt

IL0230

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface/recessed mounting - Mounting box with mirror optics louvere 2x36/40 watt

IL0231

Supplying of prewired indoor fluoresent lamp luminiaries housing of CRCA sheet steel rail, end with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for surface/recessed mounting - Mounting box with side spread mirror optics with reflector 2x36/40 watt

IL0232

Supplying of prewired call bell 250 volt A.C with base, terminal block and all accessories complete - Gong bell assembly

Supplying of prewired call bell 250 volt A.C with base, terminal block and all accessories complete - Buzzer bell assembly

Supplying of prewired call bell 250 volt A.C with base, terminal block and all accessories complete - Musical bell assembly

Supplying of 250 volt A.C prewired lighting tracks with all accessories such as current supply end assembly, right angle joint horizontal/vertical, coupler assembly, cross/tee joint, conical visor and track lighting luminiare 1 No. etc. suitable for reflector lamp 60 watt in museum or decorated shops complete - 0.5m light track

IL0260

Page 182: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 183

Department of Engineering Services, MoWHS

Code Description Quant Units MT6205 Lighting track 250 volt A.C, for 60 W reflector lamp for museum or decorated 1 each

Coefficient for per each of IL0261

Code Description Quant Units MT6206 Lighting track 250 volt A.C, for 60 W reflector lamp for museum or decorated 1 each

Coefficient for per each of IL0262

Code Description Quant Units MT6207 Lighting track 250 volt A.C, for 60 W reflector lamp for museum or decorated 1 each

CHAPTER 11: OUTDOOR LUMINIARIES (Supply)

Coefficient for per each of OL0001

Code Description Quant Units MT5753 Wall bracket louvered 275mm, 1x60/100W 1 each

Coefficient for per each of OL0002

Code Description Quant Units MT5755 Post top dia 325-380mm, 1x60/100W 1 each

Coefficient for per each of OL0015

Code Description Quant Units MT5754 Bulk head die cast aluminium body, weather proof gasket, wire guard, 1x60/1 1 each

Coefficient for per each of OL0025

Code Description Quant Units MT6060 Street Lighting - 1x36/40 W, HPF 1 each

Coefficient for per each of OL0026

Code Description Quant Units MT6061 Street Lighting - 2x36/40 W, HPF 1 each

Coefficient for per each of OL0027

Supplying of 250 volt A.C prewired lighting tracks with all accessories such as current supply end assembly, right angle joint horizontal/vertical, coupler assembly, cross/tee joint, conical visor and track lighting luminiare 1 No. etc. suitable for reflector lamp 60 watt in museum or decorated shops complete - 2m light track

IL0262

Supplying of 250 volt A.C prewired lighting tracks with all accessories such as current supply end assembly, right angle joint horizontal/vertical, coupler assembly, cross/tee joint, conical visor and track lighting luminiare 1 No. etc. suitable for reflector lamp 60 watt in museum or decorated shops complete - 1m light track

IL0261

Supplying of prewired outdoor lighting luminiaries suitable for GLS lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass, reflector, louvered, etc but without lamp - Wall bracket louvered projection 275mm, height 270mm, finish-painted, 1x60/100W

OL0001

Supplying of prewired outdoor lighting luminiaries suitable for GLS lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass, reflector, louvered, etc. but without lamp - Post top garden light dia 325-380mm, height 340-400mm, finish-painted, 1x60/100W

OL0002

Supplying of prewired outdoor bulk head fittings luminiaries having die cast aluminium body, prismatic heat resistant glass cover held in the weather proof gasket, MS galvanised wire guard, etc. Suitablefor GLS lamp 1x100/1x60 watts complete with all accessories such as base, holder, glass, reflector, louvered, etc.complete but without lamp - Projection 100mm, height 220mm, width 125mm, finish-painted, 1x60/100W

OL0015

Supplying of prewired street lighting fluoresent lamp luminiaries housing of CRCA sheet steel rail, end (with lamp holders, copper wound ballast, starter, starter holder, terminal block etc.butwithout lamp, HPF suitable for street or outdoor lighting - 1x36/40 watt

OL0025

Supplying of prewired street lighting fluoresent lamp luminiaries housing of CRCA sheet steel rail, end (with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. butwithout lamp, HPF suitable for street or outdoor lighting - 2x36/40 watt

OL0026

Supplying of prewired street lighting fluoresent lamp luminiaries housing of CRCA sheet steel rail, end (with lamp holders, copper wound ballast, starter, starter holder, terminal block etc. but without lamp, HPF suitable for street or outdoor lighting - 1x18/20 watt

OL0027

Page 183: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 184

Department of Engineering Services, MoWHS

Code Description Quant Units MT6062 Street Lighting - 1x18/20 W, HPF 1 each

Coefficient for per each of OL0040

Code Description Quant Units MT6075 Street Light Luminiareis - 1x80 W, HPL-N(BC) 1 each

Coefficient for per each of OL0041

Code Description Quant Units MT6076 Street Light Luminiareis - 1x125 W, HPL-N(BC) 1 each

Coefficient for per each of OL0042

Code Description Quant Units MT6077 Street Light Luminiareis - 1x250 W, HPL-N(ES) 1 each

Coefficient for per each of OL0055

Code Description Quant Units MT6063 Street Lighting - 1x70 W, (E) SON(BC) 1 each

Coefficient for per each of OL0056

Code Description Quant Units MT6064 Street Lighting - 1x70 W, (I)SON(BC) 1 each

Coefficient for per each of OL0057

Code Description Quant Units MT6065 Street Lighting - 1x100 W, SON(BC) 1 each

Coefficient for per each of OL0058

Code Description Quant Units MT6066 Street Lighting - 1x250 W, SON(ES) 1 each

Supplying of prewired street lighting of high pressure mercury vapour lamp luminiaries housing of CRCA sheet steel comprise of canopy, acrylic cover, control gear housing and 50/60mm outer diameter hole for bracket (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, HPF suitable for street or outdoor lighting mecury vapour lamp - 1x80 watt HPL-N(BC)

OL0040

Supplying of prewired street lighting of high pressure mercury vapour lamp luminiaries housing of CRCA sheet steel comprise of canopy, acrylic cover, control gear housing and 50/60mm outer diameter hole for bracket (with lamp holders, copper wound ballast, condenser, terminal block etc. but without suitable for street or outdoor lighting mecury vapour lamp - 1x125 watt HPL-N(BC)

OL0041

Supplying of prewired street lighting of high pressure mercury vapour lamp luminiaries housing of CRCA sheet steel comprise of canopy, acrylic cover, control gear housing and 50/60mm outer diameter hole for bracket (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, HPF suitable for street or outdoor lighting mecury vapour lamp - 1x250 watt HPL-N(ES)

OL0042

Supplying of prewired street lighting of high pressure sodium vapour lamp luminiaries housing of CRCA sheet steel comprise of canopy, acrylic cover, control gear housing and 50/60mm outer diameter hole for bracket (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, HPF suitable for street or outdoor lighting with sodium lamp - 1x70 watt (E) SON(BC)

OL0055

Supplying of prewired street lighting of high pressure sodium vapour lamp luminiaries housing of CRCA sheet steel comprise of canopy, acrylic cover, control gear housing and 50/60mm outer diameter hole for bracket (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, HPF suitable for street or outdoor lighting with sodium lamp - 1x70 watt(I) SON(BC)

OL0056

Supplying of prewired street lighting of high pressure sodium vapour lamp luminiaries housing of CRCA sheet steel comprise of canopy, acrylic cover, control gear housing and 50/60mm outer diameter hole for bracket (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, HPF suitable for street or outdoor lighting with sodium lamp - 1x100 watt SON(BC)

OL0057

Supplying of prewired street lighting of high pressure sodium vapour lamp luminiaries housing of CRCA sheet steel comprise of canopy, acrylic cover, control gear housing and 50/60mm outer diameter hole for bracket (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, HPF suitable for street or outdoor lighting with sodium lamp - 1x250 watt SON(ES)

OL0058

Page 184: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 185

Department of Engineering Services, MoWHS

Coefficient for per each of OL0070

Code Description Quant Units MT6090 Post Top Lantern - 1x80 W, HPL-N(BC) 1 each

Coefficient for per each of OL0071

Code Description Quant Units MT6091 Post Top Lantern - 1x125 W, HPL-N(ES) 1 each

Coefficient for per each of OL0072

Code Description Quant Units MT6092 Post Top Lantern - 1x160 W, ML(ES) 1 each

Coefficient for per each of OL0085

Code Description Quant Units MT6093 Post Top Lantern - 1x70 (E) W, SON(BC) 1 each

1x70(I) watt SON(BC) Coefficient for per each of OL0086

Code Description Quant Units MT6094 Post Top Lantern - 1x70(I) W, SON(BC) 1 each

Coefficient for per each of OL0087

Code Description Quant Units MT6105 Under water lighting - 60/75/100 W (R), (BC) for depth<0.60m 1 each

Coefficient for per each of OL0100

Code Description Quant Units MT6120 Flood Light Luminiare - 2x250/400 W, HPL-N(ES) 1 each

Underwater luminiare 60/75/100 watt (R)BC upto depth of 0.6m

Supplying of prewired flood lighting fixtures of high pressure mercury/sodium vapour/GLS lamp luminiaries housing of cast/spun aluminium reflector, water protected glass cover, base with lamp holder, capacitor/ignitor, copper wound ballast, terminal block etc. but without lamp, suitable for storeyard / large open area/play ground/monuments, etc - 2x250/400 watt HPL-N(ES)

OL0100

/sperical/similar HDP cover (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, suitable for compound/lawns or outdoor lighting with sodium/reflector lamp -

Supplying of prewired post top lantern/under water lighting of high pressure mercury/sodium vapour self ballasted lamp luminiaries housing of cast aluminium 50/60/80mm OD, double conical / eliptical

/sperical/similar HDP cover (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, suitable for compound/lawns or outdoor lighting with sodium/reflector lamp-

Supplying of prewired post top lantern/under water lighting of high pressure mercury/sodium vapour self ballasted lamp luminiaries housing of cast aluminium 50/60/80mm OD, double conical /eliptical

Supplying of prewired post top lantern lighting of high pressure mercury/sodium vapour self ballasted lamp luminiaries housing of cast aluminium 50/60/80mm OD, double conical / eliptical/sperical/similar HDP cover (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, suitable for compound/lawns or outdoor lighting with mercury lamp - 1x80 watt HPL-N(BC)

OL0070

Supplying of prewired post top lantern lighting of high pressure mercury/sodium vapour self ballasted lamp luminiaries housing of cast aluminium 50/60/80mm OD, double conical / eliptical/sperical/similar HDP cover (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, compound/lawns or outdoor lighting with mercury lamp - 1x125 watt HPL-N(ES)

OL0071

Supplying of prewired post top lantern lighting of high pressure mercury/sodium vapour self ballasted lamp luminiaries housing of cast aluminium 50/60/80mm OD, double conical / eliptical/sperical/similar HDP cover (with lamp holders, copper wound ballast, condenser, terminal block etc. but without lamp, suitable for compound/lawns or outdoor lighting with mercury lamp - 1x60 watt ML(ES)

OL0072

OL0086

OL0087

OL0085/sperical/similar HDP cover (with lamp holders, copper wound ballast, condenser, terminal block etc. with sodium/reflector lamp - 1x70(E) watt SON(BC)

Supplying of prewired post top lantern/under water lighting of high pressure mercury/sodium vapour self ballasted lamp luminiaries housing of cast aluminium 50/60/80mm OD, double conical /eliptical

Page 185: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 186

Department of Engineering Services, MoWHS

Coefficient for per each of OL0101

Code Description Quant Units MT6121 Flood Light Luminiare - 2x250/400 W, SON-T(ES) 1 each

Coefficient for per each of OL0102

Code Description Quant Units MT6122 Flood Light Luminiare - 1x500 W, (ES) 1 each

Coefficient for per each of OL0115

Code Description Quant Units MT6123 Flood Light Luminiare - 1x250/400 W, HPI-T 1 each

Coefficient for per each of OL0116

Code Description Quant Units MT6124 Flood Light Luminiare - Halogen lamp, 1x500 W 1 each

Coefficient for per each of OL0117

Code Description Quant Units MT6125 Flood Light Luminiare - Halogen lamp, 1 or 2x1000 W 1 each

Coefficient for per each of OL0130

Code Description Quant Units MT6140 Industrial well glass - GLS 1x200/300 W (ES) 1 each

Coefficient for per each of OL0131

Code Description Quant Units MT6141 Industrial well glass - 1x80/125 W HPL-N(BC) 1 each

Coefficient for per each of OL0132

Code Description Quant Units MT6142 Industrial well glass - 1x70/100 W (E) SON(BC) 1 each

Supplying of prewired industrial well glass luminiaries housing of die-cast aluminium alloy, porcelain holder, terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium ring,copper ballast, capacitor etc. but without lamp, suitable for GLS/HPL-N/SON lamp - watt HPL-N (BC)

OL0131

Supplying of prewired industrial well glass luminiaries housing of die-cast aluminium alloy, porcelain lamp holder, terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium ring, copper ballast, capacitor etc. but without lamp, suitable for GLS/HPL-N/SON lamp - 1x70/100 watt SON(E/I) (BC)

OL0132

Supplying of prewired flood lighting fixtures of metal halide/halogen lamp luminiaries housing of cast/spun aluminium reflector, water protected glass cover, base with lamp holder, capacitor/ignitor, copper wound ballast, terminal block etc. but without lamp, suitable for storeyard/large open area/ play ground/monuments, etc - 1 or 2x1000 watt halogen lamp

OL0117

Supplying of prewired industrial well glass luminiaries housing of die-cast aluminium alloy, porcelain lamp holder, terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium ringcopper ballast, capacitor etc. but without lamp, suitable for GLS/HPL-N/SON lamp -GLS 1x200/300 watt (ES)

OL0130

Supplying of prewired flood lighting fixtures of metal halide/halogen lamp luminiaries housing of cast/spun aluminium reflector, water protected glass cover, base with lamp holder, capacitor/ignitor,copper wound ballast, terminal block etc. but without lamp, suitable for storeyard/large open area/ play ground/monuments, etc - 2x250/400 watt HPI-T

OL0115

Supplying of prewired flood lighting fixtures of metal halide/halogen lamp luminiaries housing of cast/spun aluminium reflector, water protected glass cover, base with lamp holder, capacitor/ignitor, copper wound ballast, terminal block etc. but without lamp, suitable for storeyard/large open area/ play ground/monuments, etc - 2x500 watt halogen lamp

OL0116

Supplying of prewired flood lighting fixtures of high pressure mercury/sodium vapour/GLS lamp luminiaries housing of cast/spun aluminium reflector, water protected glass cover, base with lamp holder, capacitor/ignitor, copper wound ballast, terminal block etc. but without lamp, suitable for storeyard / large open area/play ground/monuments, etc - 2x250/400 watt SON-T(ES)

OL0101

Supplying of prewired flood lighting fixtures of high pressure mercury/sodium vapour/GLS lamp luminiaries housing of cast/spun aluminium reflector, water protected glass cover, base with lamp holder, capacitor/ignitor, copper wound ballast, terminal block etc. but without lamp, suitable for storeyard / large open area/play ground/monuments, etc - 1x500 watt(ES) GLS lamp

OL0102

Page 186: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 187

Department of Engineering Services, MoWHS

Coefficient for per each of OL0145

Code Description Quant Units MT6155 Flame proof Industrial well glass - 1x60/200 W (BC/ES) 1 each

Coefficient for per each of OL0146

Code Description Quant Units MT6156 Flame proof Industrial well glass - 1x80/125 W HPL-N(BC) 1 each

Coefficient for per each of OL0147

Code Description Quant Units MT6157 Flame proof Industrial well glass - 1x160 W ML-N(ES) 1 each

Coefficient for per each of OL0160

Code Description Quant Units MT6170 Flame proof bulk head - 1x60/200 W GLS(BC/ES) 1 each

Coefficient for per each of OL0161

Code Description Quant Units MT6171 Flame proof bulk head - 1x80/125 W (BC) 1 each

Coefficient for per each of OL0162

Code Description Quant Units MT6172 Flame proof bulk head - 1x160 W ML-N(ES) 1 each

CHAPTER 12: LAMPS & LAMP SHADE

LS0001 Coefficient for per each of LS0001

Code Description Quant Units MT6220 GLS lamp 250 volt A.C - 40 W (BC) 1 each LS0002 Coefficient for per each of LS0002

Code Description Quant Units MT6221 GLS lamp 250 volt A.C - 60 W (BC) 1 each

ring, copper ballast, capacitor etc. but without lamp, suitable for GLS/HPL-N lamp - 1x60 watt ML-N/ES)

Supplying of prewired flame proof industrial well glass luminiaries housing of die-cast aluminium alloy, porcelain lamp holder, terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium

ring, copper ballast, capacitor etc. but without lamp, suitable for GLS/HPL-N lamp - 1x80/125 watt HPL-N (BC)

Supplying of prewired flame proof industrial well glass luminiaries housing of die-cast aluminium alloy, porcelain lamp holder,terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium

Supplying of prewired flame proof bulk head luminiaries housing of die-cast aluminium alloy, porcelain lamp holder, terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium ring, copper ballast, capacitor etc. but without lamp, suitable for HPL-N/ML-N lamp - 1x60/200 watt GLS (BC/ES)

OL0160

Supplying of prewired flame proof bulk head luminiaries housing of die-cast aluminium alloy, porcelain lamp holder, terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium ring, copper ballast, capacitor etc. but without lamp, suitable for HPL-N/ML-N lamp - HPL-N lamp 1x80/125 watt (BC)

copper ballast, capacitor etc. but without lamp, suitable for GLS/HPL-N lamp - GLS 1x60/200 watt (BC/ES)OL0145

Supplying of prewired flame proof bulk head luminiaries housing of die-cast aluminium alloy, porcelain lamp holder, terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium ring, copper ballast, capacitor etc. but without lamp, suitable for HPL-N/ML-N lamp - 1x60 watt ML-N

OL0162

OL0161

OL0146

OL0147

Supplying of prewired flame proof industrial well glass luminiaries housing of die-cast aluminium alloy, porcelain lamp holder, terminal block, heat resistant glass cover, wire guard, rubber gasket, aluminium ring,

Supplying of GLS lamps 250 volts A.C - GLS lamp 40 watt (BC)

Supplying of GLS lamps 250 volts A.C - GLS lamp 60 watt (BC)

Page 187: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 188

Department of Engineering Services, MoWHS

LS0003 Coefficient for per each of LS0003

Code Description Quant Units MT6222 GLS lamp 250 volt A.C - 100 W (BC) 1 each LS0004 Coefficient for per each of LS0004

Code Description Quant Units MT6223 GLS lamp 250 volt A.C - 150 W (ES) 1 each LS0005 Coefficient for per each of LS0005

Code Description Quant Units MT6224 GLS lamp 250 volt A.C - 200 W (ES) 1 each LS0006 Coefficient for per each of LS0006

Code Description Quant Units MT6225 GLS lamp 250 volt A.C - 300 W (ES) 1 each LS0020 Coefficient for per each of LS0020

Code Description Quant Units MT6226 GLS lamp 250 volt A.C - 500 W (ES) 1 each LS0021 Coefficient for per each of LS0021

Code Description Quant Units MT6235 Reflector lamp 250 volt A.C - 60 W (R) 63(BC) 1 each LS0022 Coefficient for per each of LS0022

Code Description Quant Units MT6236 Reflector lamp 250 volt A.C - 75 W (R) 95(BC/ES) 1 each

LS0035

Coefficient for per each of LS0035

Code Description Quant Units MT6237 Reflector lamp 250 volt A.C - 100 W (R) 95(BC/ES) 1 each LS0036 Coefficient for per each of LS0036

Code Description Quant Units MT6238 Reflector lamp 250 volt A.C - 150 W (R) 95(BC/ES) 1 each LS0037 Coefficient for per each of LS0037

Code Description Quant Units MT6250 ML blended lamp 250 volt A.C - 60 W (BC/ES) 1 each

Supplying of reflector/ML blended/ self ballasted lamps 250 volts A.C - ML-N lamp 160 watt (BC/ES)

Supplying of GLS lamps 250 volts A.C - GLS lamp 100 watt (BC)

Supplying of reflector/ML blended/ self ballasted lamps 250 volts A.C - Reflector lamp 150 watt 95(BC/ES)

Supplying of GLS/reflector lamps 250 volts A.C - Reflector lamp 60 watt 63(BC)

Supplying of GLS/reflector lamps 250 volts A.C - Reflector lamp 75 watt 95(BC/ES)

Supplying of reflector/ML blended/ self ballasted lamps 250 volts A.C - Reflector lamp 100 watt (R)

Supplying of GLS lamps 250 volts A.C - GLS lamp 150 watt (ES)

Supplying of GLS lamps 250 volts A.C - GLS lamp 200 watt (ES)

Supplying of GLS lamps 250 volts A.C - GLS lamp 100 watt (ES)

Supplying of GLS/reflector lamps 250 volts A.C - GLS lamp 500 watt (ES)

Page 188: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 189

Department of Engineering Services, MoWHS

LS0050 Coefficient for per each of LS0050

Code Description Quant Units MT6265 High pressure mercury vapour lamp 250 volt A.C - HPL-N 80 W (BC/ES) 1 each LS0051 Coefficient for per each of LS0051

Code Description Quant Units MT6266 High pressure mercury vapour lamp 250 volt A.C - HPL-N 125 W (BC/ES) 1 each LS0052 Coefficient for per each of LS0052

Code Description Quant Units MT6267 High pressure mercury vapour lamp 250 volt A.C - HPL-N 250 W (ES) 1 each LS0065 Coefficient for per each of LS0065

Code Description Quant Units MT6268 High pressure mercury vapour lamp 250 volt A.C - HPL-N 400 W (ES) 1 each LS0066 Coefficient for per each of LS0066

Code Description Quant Units MT6285 High pressure sodium vapour lamp 250 volt A.C - SON-T 70 W (E)(BC) 1 each LS0067 Coefficient for per each of LS0067

Code Description Quant Units MT6286 High pressure sodium vapour lamp 250 volt A.C - SON-T 70 W (I) (BC) 1 each LS0080 Coefficient for per each of LS0080

Code Description Quant Units MT6287 High pressure sodium vapour lamp 250 volt A.C - SON-T 150 W (ES) 1 each LS0081 Coefficient for per each of LS0081

Code Description Quant Units MT6288 High pressure sodium vapour lamp 250 volt A.C - SON-T 250 W (ES) 1 each LS0082 Coefficient for per each of LS0082

Code Description Quant Units MT6289 High pressure sodium vapour lamp 250 volt A.C - SON-T 400 W (ES) 1 each LS0095 Coefficient for per each of LS0095

Code Description Quant Units MT6300 Metal halide lamp 250 volt A.C - HPI-T 250 W (ES) 1 each

Supplying of high pressure mercury/sodium vapour lamps 250 volts A.C - SON-T lamp 70 watt (I) (BC)

Supplying of high pressure sodium vapour lamps 250 volts A.C - SON-T lamp 150 watt (ES)

Supplying of high pressure mercury vapour lamps 250 volts A.C - HPL-N lamp 80 watt (BC/ES)

Supplying of high pressure mercury/sodium vapour lamps 250 volts A.C - HPL-N lamp 400 watt (ES)

Supplying of high pressure mercury/sodium vapour lamps 250 volts A.C - SON-T lamp 70 watt (E) (BC)

Supplying of high pressure mercury vapour lamps 250 volts A.C - HPL-N lamp 125 watt (BC/ES)

Supplying of high pressure mercury vapour lamps 250 volts A.C - HPL-N lamp 250 watt (ES)

Supplying of high pressure sodium vapour lamps 250 volts A.C - SON-T lamp 250 watt (ES)

Supplying of high pressure sodium vapour lamps 250 volts A.C - SON-T lamp 400 watt (ES)

Supplying of high pressure metal halide/halogen lamps 250 volts A.C - HPI-T lamp 250 watt (ES)

Page 189: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 190

Department of Engineering Services, MoWHS

LS0096 Coefficient for per each of LS0096

Code Description Quant Units MT6301 Metal halide lamp 250 volt A.C - HPI-T 400 W (ES) 1 each LS0097 Coefficient for per each of LS0097

Code Description Quant Units MT6315 Halogen lamp 250 volt A.C - 7785 R 500 W 1 each LS0110 Coefficient for per each of LS0110

Code Description Quant Units MT6316 Halogen lamp 250 volt A.C - 12013 R 1000 W 1 each

LS0111

Coefficient for per each of LS0111

Code Description Quant Units MT6325 Argenta superlux lamp 250 volt A.C - 60 W (BC) 1 each

LS0112

Coefficient for per each of LS0112

Code Description Quant Units MT6335 Special incandescent lamp 250 volt A.C - 15 W (BC) pigmy 1 each LS0125 Coefficient for per each of LS0125

Code Description Quant Units MT6345 Fluorescent lamp 250 volt A.C - TL 18/20 W 1 each LS0126 Coefficient for per each of LS0126

Code Description Quant Units MT6346 Fluorescent lamp 250 volt A.C - TL 36/40 W 1 each LS0127 Coefficient for per each of LS0127

Code Description Quant Units MT6347 Fluorescent lamp 250 volt A.C - TLF 36/40 W 1 each

LS0140

Coefficient for per each of LS0140

Code Description Quant Units MT6355 Glass globe - 150mm dia 1 each

LS0141

Coefficient for per each of LS0141

Code Description Quant Units MT6356 Glass globe - 180mm dia 1 each

Supplying of high pressure metal halide/halogen lamps 250 volts A.C - Halogen lamp 7785 R 500 watt

Supplying of halogen/argenta superlux/special incandescent lamps 250 volts A.C - Halogen 12013 R 1000 watt

Supplying of halogen/argenta superlux/special incandescent lamps 250 volts A.C - Argenta superlux 60 watt (BC)

Supplying of halogen/argenta superlux/special incandescent lamps 250 volts A.C - 15 watt (BC) pigmy lamp

Supplying of high pressure metal halide/halogen lamps 250 volts A.C - HPI-T lamp 400 watt (ES)

Supplying of glass globe/glass lengum shade as required to make the existing fitting good - Glass globe 180mm dia

Supplying of fluorescent lamps 250 volts A.C - TL lamp 18/20 watt

Supplying of fluorescent lamps 250 volts A.C - TL lamp 36/40 watt

Supplying of fluorescent lamps 250 volts A.C - TLF lamp 36/40 watt

Supplying of glass globe/glass lengum shade as required to make the existing fitting good - Glass globe 150mm dia

Page 190: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 191

Department of Engineering Services, MoWHS

LS0142

Coefficient for per each of LS0142

Code Description Quant Units MT6365 Glass lengum shade - 150mm dia 1 each

LS0155

Coefficient for per each of LS0155

Code Description Quant Units MT6366 Glass lengum shade - 180mm dia 1 each

LS0156

Coefficient for per each of LS0156

Code Description Quant Units MT6375 Heat resistant proof plastic conical shade - 150mm dia 1 each

LS0157

Coefficient for per each of LS0157

Code Description Quant Units MT6385 Heat resistant proof plastic coolican shade - 150mm dia 1 each

CHAPTER 13: FANS (Supply)

FN0001

Coefficient for per each of FN0001

Code Description Quant Units MT6395 Ceiling fan 240 volt A.C - 1400 rpm, 900mm sweep 1 each

FN0002

Coefficient for per each of FN0002

Code Description Quant Units MT6396 Ceiling fan 240 volt A.C - 1400 rpm, 1200mm sweep 1 each

FN0003

Coefficient for per each of FN0003

Code Description Quant Units MT6397 Ceiling fan 240 volt A.C - 1400 rpm, 1400mm sweep 1 each

FN0015

Coefficient for per each of FN0015

Code Description Quant Units MT6415 Exhaust fan 240 volt A.C - 900 rpm, 300mm sweep 1 each

FN0016

Coefficient for per each of FN0016

Code Description Quant Units MT6416 Exhaust fan 240 volt A.C - 900 rpm, 380mm sweep 1 each

Supplying of ceiling fan 240 volt A.C 1400 rpm with all accessories such as down rod, sweep 3 Nos., canopy 2 Nos., condenser and fan body etc. complete as required - 1200mm sweep

Supplying of ceiling fan 240 volt A.C 1400 rpm with all accessories such as down rod, sweep 3 Nos., canopy 2 Nos., condenser and fan body etc. complete as required - 1400mm sweep

Supplying of exhaust fan 240 volt A.C 900 rpm with all accessories such as frame with arm 3 Nos., sweep 3 Nos., condenser and fan body etc. complete as required - 300mm sweep

Supplying of exhaust fan 240 volt A.C 900 rpm with all accessories such as frame with arm 3 Nos., sweep 3 Nos., condenser and fan body etc. complete as required - 380mm sweep

Supplying of glass lengum shade/heat resistant proof plastic conical/coonican shade as required to make the existing fitting good - PLastic heat resistant shade 150mm dia

Supplying of glass lengum shade/heat resistant proof plastic conical/coonican shade as required to make the existing fitting good - Glass lengum shade 180mm dia

Supplying of glass globe/glass lengum shade as required to make the existing fitting good - Glass lengum shade 150mm dia

Supplying of glass lengum shade/heat resistant proof plastic conical/coonican shade as required to make the existing fitting good - Plastic heat resistant coonican shade 150mm dia

Supplying of ceiling fan 240 volt A.C 1400 rpm with all accessories such as down rod, sweep 3 Nos., canopy 2 Nos., condenser and fan body etc. complete as required - 900mm sweep

Page 191: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 192

Department of Engineering Services, MoWHS

FN0017

Coefficient for per each of FN0017

Code Description Quant Units MT6417 Exhaust fan 240 volt A.C - 900 rpm, 450mm sweep 1 each

FN0030

Coefficient for per each of FN0030

Code Description Quant Units MT6418 Exhaust fan 240 volt A.C - 1400 rpm, 300mm sweep 1 each

FN0031

Coefficient for per each of FN0031

Code Description Quant Units MT6419 Exhaust fan 240 volt A.C - 1400 rpm, 380mm sweep 1 each

FN0032

Coefficient for per each of FN0032

Code Description Quant Units MT6420 Exhaust fan 240 volt A.C - 1400 rpm, 450mm sweep 1 each FN0045 Coefficient for per each of FN0045

Code Description Quant Units MT6435 Aluminium louvere with frame - 300mm sweep 1 each FN0046 Coefficient for per each of FN0046

Code Description Quant Units MT6436 Aluminium louvere with frame - 380mm sweep 1 each FN0047 Coefficient for per each of FN0047

Code Description Quant Units MT6437 Aluminium louvere with frame - 450mm sweep 1 each

CHAPTER 14: CONTROL GEAR & BUSBAR (Supply)

GB0001

Coefficient for per each of GB0001

Code Description Quant Units MT4960 Copper Busbars & MS Busbar Chamber - 2 strips, 300mm bar, 100A 1 each

GB0002

Coefficient for per each of GB0002

Code Description Quant Units MT4961 Copper Busbars & MS Busbar Chamber - 4 strips, 300mm bar, 100A 1 each

Supplying of exhaust fan 240 volt A.C 1400 rpm with all accessories such as frame with arm 3 Nos., sweep 3 Nos., condenser and fan body etc. complete as required - 380mm sweep

Supplying of exhaust fan 240 volt A.C 1400 rpm with all accessories such as frame with arm 3 Nos., sweep 3 Nos., condenser and fan body etc. complete as required - 450mm sweep

Supplying of exhaust fan 240 volt A.C 900 rpm with all accessories such as frame with arm 3 Nos., sweep 3 Nos., condenser and fan body etc. complete as required - 450mm sweep

Supplying of exhaust fan 240 volt A.C 1400 rpm with all accessories such as frame with arm 3 Nos., sweep 3 Nos., condenser and fan body etc. complete as required - 300mm sweep

Supplying of Aluminium louveres for exhaust fan complete all accessories as required - 300mm sweep

Supplying of Aluminium louveres for exhaust fan complete all accessories as required - 380mm sweep

Supplying of Aluminium louveres for exhaust fan complete all accessories as required - 450mm sweep

Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 2 strips, 300mm bar, 100A

Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 4 strips, 300mm bar, 100A

Page 192: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 193

Department of Engineering Services, MoWHS

GB0003

Coefficient for per each of GB0003

Code Description Quant Units MT4962 Copper Busbars & MS Busbar Chamber - 4 strips, 300mm bar, 200A 1 each

GB0004

Coefficient for per each of GB0004

Code Description Quant Units MT4963 Copper Busbars & MS Busbar Chamber - 2 strips, 450mm bar, 100A 1 each

GB0005

Coefficient for per each of GB0005

Code Description Quant Units MT4964 Copper Busbars & MS Busbar Chamber - 4 strips, 450mm bar, 100A 1 each

GB0006

Coefficient for per each of GB0006

Code Description Quant Units MT4965 Copper Busbars & MS Busbar Chamber - 4 strips, 450mm bar, 200A 1 each

GB0007

Coefficient for per each of GB0007

Code Description Quant Units MT4966 Copper Busbars & MS Busbar Chamber - 4 strips, 600mm bar, 100A 1 each

GB0008

Coefficient for per each of GB0008

Code Description Quant Units MT4967 Copper Busbars & MS Busbar Chamber - 4 strips, 600mm bar, 200A 1 each

GB0009

Coefficient for per each of GB0009

Code Description Quant Units MT4968 Copper Busbars & MS Busbar Chamber - 4 strips, 600mm bar, 300A 1 each

GB0025

Coefficient for per each of GB0025

Code Description Quant Units

MT4980Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 600mm bar, 300A 1 each

GB0026

Coefficient for per each of GB0026

Code Description Quant Units

MT4981Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 600mm bar, 400A 1 each

Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 4 strips, 300mm bar, 200A

Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 2 strips, 450mm bar, 100A

Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 4 strips, 450mm bar, 100A

Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 4 strips, 450mm bar, 200A

Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 4 strips, 600mm bar,100A

Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 4 strips, 600mm bar, 200A

Supplying of pre-fabricated MS busbar chamber with copper busbar complete with all accessories etc. as required - 4 strips, 600mm bar, 300A

Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 600mm bar, 300A

Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 600mm bar, 400A

Page 193: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 194

Department of Engineering Services, MoWHS

GB0027

Coefficient for per each of GB0027

Code Description Quant Units

MT4982Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 600mm bar, 600A 1 each

GB0028

Coefficient for per each of GB0028

Code Description Quant Units

MT4983Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 900mm bar, 400A 1 each

GB0029

Coefficient for per each of GB0029

Code Description Quant Units

MT4984Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 900mm bar, 600A 1 each

GB0030

Coefficient for per each of GB0030

Code Description Quant Units

MT4985Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 900mm bar, 800A 1 each

GB0031

Coefficient for per each of GB0031

Code Description Quant Units

MT4986Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 1350mm bar, 400A 1 each

GB0032

Coefficient for per each of GB0032

Code Description Quant Units

MT4987Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 1350mm bar, 600A 1 each

GB0033

Coefficient for per each of GB0033

Code Description Quant Units

MT4988Aluminium alloy/wrought Busbars suitable for cubical panel board - 4 strips, 1350mm bar, 800A 1 each

GB0050

Coefficient for per each of GB0050

Code Description Quant Units

MT5000 Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 20A, 415V 1 each MT5045 HRC Fuses - 20A, 415V size 0 3 each

Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 600mm bar, 600A

Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 900mm bar, 400A

Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 900mm bar, 600A

Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 900mm bar, 800A

Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 1350mm bar, 400A

Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 1350mm bar, 600A

Supplying of Aluminium alloy/wrought aluminium busbar complete with all accessories etc. to accomodate in prefabricated MS cubical panel board as required - 4 strips, 1350mm bar, 800A

Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN switch fuse unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 20A

Page 194: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 195

Department of Engineering Services, MoWHS

GB0051

Coefficient for per each of GB0051

Code Description Quant Units

MT5001 Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 32A,415V, SFU 1 each MT5046 HRC Fuses - 32A, 415V size 0 3 each

GB0052

Coefficient for per each of GB0052

Code Description Quant Units

MT5002 Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 63A,415V, SFU 1 each MT5047 HRC Fuses - 63A, 415V size 0 3 each

GB0053

Coefficient for per each of GB0053

Code Description Quant Units

MT5006Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 125A, 415V, SFU 1 each

MT5048 HRC Fuses - 125A, 415V size 1 3 each

GB0065

Coefficient for per each of GB0065

Code Description Quant Units

MT5003Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 200A,415V, FSU 1 each

MT5049 HRC Fuses - 200A, 415V size 1 3 each

GB0066

Coefficient for per each of GB0066

Code Description Quant Units

MT5004Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 250A, 415V, FSU 1 each

MT5050 HRC Fuses - 250A, 415V size 1 3 each

GB0067

Coefficient for per each of GB0067

Code Description Quant Units

MT5005Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 315A, 415V, FSU 1 each

MT5051 HRC Fuses - 315A, 415V size 2 3 each

GB0068

Coefficient for per each of GB0068

Code Description Quant Units

MT5007Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 400A,415V, FSU 1 each

MT5052 HRC Fuses - 400A, 415V size 2 3 each

Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN switch fuse unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 32A

Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN switch fuse unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 63A

Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN switch fuse unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 125A

Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN fuse switch unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 200A

Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN fuse switch unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 250A

Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN fuse switch unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 315A

Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN fuse switch unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 400A

Page 195: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 196

Department of Engineering Services, MoWHS

GB0069

Coefficient for per each of GB0069

Code Description Quant Units

MT5008Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 500A,415V, FSU 1 each

MT5053 HRC Fuses - 500A, 415V size 3 3 each

GB0070

Coefficient for per each of GB0070

Code Description Quant Units

MT5009Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 630A,415V, FSU 1 each

MT5054 HRC Fuses - 630A, 415V size 3 3 each

GB0071

Coefficient for per each of GB0071

Code Description Quant Units

MT5011Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 800A,415V, FSU 1 each

MT5056 HRC Fuses - 800A, 415V size 3 3 each

GB0085

Coefficient for per each of GB0085

Code Description Quant Units

MT5012Wall mounting Fuse Switch Units sheet steel enclosure - 4 pole, 500A, 415V, FSU 1 each

MT5053 HRC Fuses - 500A, 415V size 3 4 each

Coefficient for per each of GB0095

Code Description Quant Units

MT5004Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 250A, 415V, FSU 1 each

MT5050 HRC Fuses - 250A, 415V size 1 4 each

Coefficient for per each of GB0096

Code Description Quant Units

MT5007Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 400A, 415V, FSU 1 each

MT5052 HRC Fuses - 400A, 415V size 2 4 each

Coefficient for per each of GB0097

Code Description Quant Units

MT5010 Wall mounting Fuse Switch Units sheet steel enclosure - TPN, 750A,415V FSU 1 each MT5055 HRC Fuses-750A, 415V Size 3 4 each

Supplying of wall mounting combination fuse switch unit with sheet steel enclosure /panel mounting disconnector fuse switch unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 4 pole with HRC fuses and all accessories etc. as required - 400A

GB0096

Supplying of wall mounting combination fuse switch unit with sheet steel enclosure /panel mounting disconnector fuse switch unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 4 pole with HRC fuses and all accessories etc. as required - 750A

GB0097

Supplying of wall mounting combination fuse switch unit with sheet steel enclosure /panel mounting disconnector fuse switch unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 4 pole with HRC fuses and all accessories etc. as required - 250A

GB0095

Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN fuse switch unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 500A

Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN fuse switch unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 630A

Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure TPN fuse switch unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 800A

Supplying of wall mounting combination fuse switch unit (HRC) with steel enclosure 4 pole fuse switch unit, 415 volt A.C complete with HRC fuses and all accessories etc. as required - 500A

Page 196: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 197

Department of Engineering Services, MoWHS

Coefficient for per each of GB0110

Code Description Quant Units

MT5028Panel mounting disconnector FSU complete with front drive mechanism with door interlock (HRC fuse)-3 pole, 32A, 415V, SFU 1 each

MT5046 HRC Fuses - 32A, 415V size 0 3 each

Coefficient for per each of GB0111

Code Description Quant Units

MT5029Panel mounting disconnector FSU complete with front drive mechanism with door interlock (HRC fuse)-3 pole, 63A, 415V, SFU 1 each

MT5047 HRC Fuses - 63A, 415V size 0 3 each

Coefficient for per each of GB0112

Code Description Quant Units

MT5030Panel mounting disconnector FSU complete with front drive mechanism with door interlock (HRC fuse)-3 pole, 125A, 415V, SFU 1 each

MT5048 HRC Fuses - 125A, 415V size 1 3 each

Coefficient for per each of GB0125

Code Description Quant Units

MT5031Panel mounting disconnector FSU complete with front drive mechanism with door interlock (HRC fuse)-3 pole, 250A, 415V, FSU 1 each

MT5050 HRC Fuses - 250A, 415V size 1 3 each

Coefficient for per each of GB0126

Code Description Quant Units

MT5032Panel mounting disconnector FSU complete with front drive mechanism with door interlock (HRC fuse)-3 pole, 400A, 415V, FSU 1 each

MT5052 HRC Fuses - 400A, 415V size 2 3 each

Coefficient for per each of GB0140

Code Description Quant Units

MT5027Panel mounting disconnector FSU complete with front drive mechanism with door interlock (HRC fuse)-4 pole, 125A, 415V, SFU 1 each

MT5048 HRC Fuses - 125A, 415V size 1 4 each

GB0150

Coefficient for per each of GB0150

Code Description Quant Units MT5640 3 pole, 16KA, MCCB 63A, 415V 1 each

GB0151

Coefficient for per each of GB0151

Code Description Quant Units MT5641 3 pole, 16KA, MCCB 100A, 415V 1 each

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 16KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 63A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 16KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 100A

Supplying of panel mounting switch disconnector fuse switch unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 3 pole fuse switch unit with HRC fuses and all accessories etc. as required - 400A

GB0126

Supplying of panel mounting switch disconnector switch fuse unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 4 pole switch fuse unit with HRC fuses and all accessories etc. as required - 125A

GB0140

Supplying of panel mounting switch disconnector switch fuse unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 3 pole switch fuse unit with HRC fuses and all accessories etc. as required - 125A

GB0112

Supplying of panel mounting switch disconnector fuse switch unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 3 pole fuse switch unit with HRC fuses and all accessories etc. as required - 250A

GB0125

Supplying of panel mounting switch disconnector switch fuse unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 3 pole switch fuse unit with HRC fuses and all accessories etc. as required - 32A

GB0110

Supplying of panel mounting switch disconnector switch fuse unit 415 volt A.C complete with front drive mechnism with door interlock HRC fuses 3 pole switch fuse unit with HRC fuses and all accessories etc. as required - 63A

GB0111

Page 197: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 198

Department of Engineering Services, MoWHS

GB0152

Coefficient for per each of GB0152

Code Description Quant Units MT5642 3 pole, 16KA, MCCB 125A, 415V 1 each

GB0165

Coefficient for per each of GB0165

Code Description Quant Units MT5643 4 pole, 16KA, MCCB 63A, 415V 1 each

GB0166

Coefficient for per each of GB0166

Code Description Quant Units MT5644 4 pole, 16KA, MCCB 100A, 415V 1 each

GB0167

Coefficient for per each of GB0167

Code Description Quant Units MT5645 4 pole, 16KA, MCCB 125A, 415V 1 each

GB0180

Coefficient for per each of GB0180

Code Description Quant Units MT5646 3 pole, 25KA, MCCB 63A, 415V 1 each

GB0181

Coefficient for per each of GB0181

Code Description Quant Units MT5647 3 pole, 25KA, MCCB 100A, 415V 1 each

GB0182

Coefficient for per each of GB0182

Code Description Quant Units MT5648 3 pole, 25KA, MCCB 125A, 415V 1 each

GB0195

Coefficient for per each of GB0195

Code Description Quant Units MT5649 4 pole, 25KA, MCCB 63A, 415V 1 each

GB0196

Coefficient for per each of GB0196

Code Description Quant Units MT5650 4 pole, 25KA, MCCB 100A, 415V 1 each

GB0197

Coefficient for per each of GB0197

Code Description Quant Units MT5651 4 pole, 25KA, MCCB 125A, 415V 1 each

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 25KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 63A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 25KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 100A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 25KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 125A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 16KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 125A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 16KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 63A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 16KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 100A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 16KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 125A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 25KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 63A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 25KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 100A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 25KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 125A

Page 198: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 199

Department of Engineering Services, MoWHS

GB0210

Coefficient for per each of GB0210

Code Description Quant Units MT5652 3 pole, 36KA, MCCB 125A, 415V 1 each

GB0211

Coefficient for per each of GB0211

Code Description Quant Units MT5653 3 pole, 36KA, MCCB 160A, 415V 1 each

GB0212

Coefficient for per each of GB0212

Code Description Quant Units MT5654 3 pole, 36KA, MCCB 250A, 415V 1 each

GB0225

Coefficient for per each of GB0225

Code Description Quant Units MT5655 4 pole, 36KA, MCCB 125A, 415V 1 each

GB0226

Coefficient for per each of GB0226

Code Description Quant Units MT5656 4 pole, 36KA, MCCB 160A, 415V 1 each

GB0227

Coefficient for per each of GB0227

Code Description Quant Units MT5657 4 pole, 36KA, MCCB 250A, 415V 1 each

GB0240

Coefficient for per each of GB0240

Code Description Quant Units MT5658 4 pole, 70KA, MCCB 250A, 415V 1 each

GB0241

Coefficient for per each of GB0241

Code Description Quant Units MT5659 4 pole, 70KA, MCCB 400A, 415V 1 each

GB0242

Coefficient for per each of GB0242

Code Description Quant Units MT5660 4 pole, 70KA, MCCB 630A, 415V 1 each

GB0243

Coefficient for per each of GB0243

Code Description Quant Units MT5661 4 pole, 70KA, MCCB 800A, 415V 1 each

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 70KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 800A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 36KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 125A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 36KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 160A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 36KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 250A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 70KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 250A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 70KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 400A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 70KA, 4 pole 415 volt A.C complete with all accessories etc. as required - 630A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 36KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 125A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 36KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 160A

Supplying of panel moulded case circuit breaker (MCCB) with electronic release, breaking capacity 36KA, 3 pole 415 volt A.C complete with all accessories etc. as required - 250A

Page 199: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 200

Department of Engineering Services, MoWHS

GB255

Coefficient for per each of GB0255

Code Description Quant Units MT5070 Earth leakage module, 4 pole, 415 volt A.C - 125A 1 each

GB0256

Coefficient for per each of GB0256

Code Description Quant Units MT5071 Earth leakage module, 4 pole, 415 volt A.C - 160A 1 each

GB0257

Coefficient for per each of GB0257

Code Description Quant Units MT5072 Earth leakage module, 4 pole, 415 volt A.C - 250A 1 each

GB0258

Coefficient for per each of GB0258

Code Description Quant Units MT5073 Earth leakage module, 4 pole, 415 volt A.C - 400A 1 each

GB0259

Coefficient for per each of GB0259

Code Description Quant Units MT5074 Earth leakage module, 4 pole, 415 volt A.C - 630A 1 each

GB0270

Coefficient for per each of GB0270

Code Description Quant Units MT5085 Single pole MCB 230 volt A.C - 6A 1 each

GB0271

Coefficient for per each of GB0271

Code Description Quant Units MT5086 Single pole MCB 230 volt A.C - 10A 1 each

GB0272

Coefficient for per each of GB0272

Code Description Quant Units MT5087 Single pole MCB 230 volt A.C - 16A 1 each

GB0273

Coefficient for per each of GB0273

Code Description Quant Units MT5088 Single pole MCB 230 volt A.C - 20A 1 each

GB0274

Coefficient for per each of GB0274

Code Description Quant Units MT5089 Single pole MCB 230 volt A.C - 25A 1 each

GB0275

Coefficient for per each of GB0275

Code Description Quant Units MT5090 Single pole MCB 230 volt A.C - 32A 1 each

Supply of miniature circuit breaker (MCB) single pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 6A

Supply of miniature circuit breaker (MCB) single pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A

Supply of miniature circuit breaker (MCB) single pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 20A

Supply of miniature circuit breaker (MCB) single pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A

Supply of miniature circuit breaker (MCB) single pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A

Supply of miniature circuit breaker (MCB) single pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 10A

Supply of panel mounting earth leakage module 4 pole, 415 volt A.C complete with all accessories as required - 125A

Supply of panel mounting earth leakage module 4 pole, 415 volt A.C complete with all accessories as required - 160A

Supply of panel mounting earth leakage module 4 pole, 415 volt A.C complete with all accessories as required - 250A

Supply of panel mounting earth leakage module 4 pole, 415 volt A.C complete with all accessories as required - 400A

Supply of panel mounting earth leakage module 4 pole, 415 volt A.C complete with all accessories as required - 630A

Page 200: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 201

Department of Engineering Services, MoWHS

GB0276

Coefficient for per each of GB0276

Code Description Quant Units MT5091 Single pole MCB 230 volt A.C - 40A 1 each

GB0277

Coefficient for per each of GB0277

Code Description Quant Units MT5092 Single pole MCB 230 volt A.C - 63A 1 each

GB0290

Coefficient for per each of GB0290

Code Description Quant Units MT5115 SPN MCB, 230 volt A.C - 6A 1 each

GB0291

Coefficient for per each of GB0291

Code Description Quant Units MT5116 SPN MCB, 230 volt A.C - 10A 1 each

GB0292

Coefficient for per each of GB0292

Code Description Quant Units MT5117 SPN MCB, 230 volt A.C - 16A 1 each

GB0293

Coefficient for per each of GB0293

Code Description Quant Units MT5118 SPN MCB, 230 volt A.C - 20A 1 each

GB0294

Coefficient for per each of GB0294

Code Description Quant Units MT5119 SPN MCB, 230 volt A.C - 25A 1 each

GB0295

Coefficient for per each of GB0295

Code Description Quant Units MT5120 SPN MCB, 230 volt A.C - 32A 1 each

GB0296

Coefficient for per each of GB0296

Code Description Quant Units MT5121 SPN MCB, 230 volt A.C - 40A 1 each

GB0297

Coefficient for per each of GB0297

Code Description Quant Units MT5122 SPN MCB, 230 volt A.C - 63A 1 each

GB0310

Coefficient for per each of GB0310

Code Description Quant Units MT5145 2 pole MCB, 230 volt A.C - 6A 1 each

Supply of miniature circuit breaker (MCB) SPN, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A

Supply of miniature circuit breaker (MCB) SPN, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A

Supply of miniature circuit breaker (MCB) SPN, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A

Supply of miniature circuit breaker (MCB) SPN, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A

Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 6A

Supply of miniature circuit breaker (MCB) single pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A

Supply of miniature circuit breaker (MCB) single pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A

Supply of miniature circuit breaker (MCB) SPN, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 6A

Supply of miniature circuit breaker (MCB) SPN, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 10A

Supply of miniature circuit breaker (MCB) SPN, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A

Supply of miniature circuit breaker (MCB) SPN, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 20A

Page 201: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 202

Department of Engineering Services, MoWHS

GB0311

Coefficient for per each of GB0311

Code Description Quant Units MT5146 2 pole MCB, 230 volt A.C - 10A 1 each

GB0312

Coefficient for per each of GB0312

Code Description Quant Units MT5147 2 pole MCB, 230 volt A.C - 16A 1 each

GB0313

Coefficient for per each of GB0313

Code Description Quant Units MT5148 2 pole MCB, 230 volt A.C - 20A 1 each

GB0314

Coefficient for per each of GB0314

Code Description Quant Units MT5149 2 pole MCB, 230 volt A.C - 25A 1 each

GB0315

Coefficient for per each of GB0315

Code Description Quant Units MT5150 2 pole MCB, 230 volt A.C - 32A 1 each

GB0316

Coefficient for per each of GB0316

Code Description Quant Units MT5151 2 pole MCB, 230 volt A.C - 40A 1 each

GB0317

Coefficient for per each of GB0317

Code Description Quant Units MT5152 2 pole MCB, 230 volt A.C - 50A 1 each

GB0318

Coefficient for per each of GB0318

Code Description Quant Units MT5153 2 pole MCB, 230 volt A.C - 63A 1 each

GB0330

Coefficient for per each of GB0330

Code Description Quant Units MT5180 TP MCB, 415 volt A.C - 6A 1 each

GB0331

Coefficient for per each of GB0331

Code Description Quant Units MT5181 TP MCB, 415 volt A.C - 10A 1 each

GB0332

Coefficient for per each of GB0332

Code Description Quant Units MT5182 TP MCB, 415 volt A.C - 16A 1 each

Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A

Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 6A

Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 10A

Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A

Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A

Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 20A

Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A

Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A

Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A

Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 50A

Supply of miniature circuit breaker (MCB) double pole, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 10A

Page 202: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 203

Department of Engineering Services, MoWHS

GB0333

Coefficient for per each of GB0333

Code Description Quant Units MT5183 TP MCB, 415 volt A.C - 20A 1 each

GB0334

Coefficient for per each of GB03432

Code Description Quant Units MT5184 TP MCB, 415 volt A.C - 25A 1 each

GB0335

Coefficient for per each of GB0335

Code Description Quant Units MT5185 TP MCB, 415 volt A.C - 32A 1 each

GB0336

Coefficient for per each of GB0336

Code Description Quant Units MT5186 TP MCB, 415 volt A.C - 40A 1 each

GB0337

Coefficient for per each of GB0337

Code Description Quant Units MT5187 TP MCB, 415 volt A.C - 50A 1 each

GB0338

Coefficient for per each of GB0338

Code Description Quant Units MT5188 TP MCB, 415 volt A.C - 63A 1 each

GB0350

Coefficient for per each of GB0350

Code Description Quant Units MT5223 TPN MCB, 415 volt A.C - 20A 1 each

GB0351

Coefficient for per each of GB0351

Code Description Quant Units MT5224 TPN MCB, 415 volt A.C - 25A 1 each

GB0352

Coefficient for per each of GB0352

Code Description Quant Units MT5225 TPN MCB, 415 volt A.C - 32A 1 each

GB0353

Coefficient for per each of GB0353

Code Description Quant Units MT5226 TPN MCB, 415 volt A.C - 40A 1 each

GB0354

Coefficient for per each of GB0354

Code Description Quant Units MT5227 TPN MCB, 415 volt A.C - 50A 1 each

Supply of miniature circuit breaker (MCB) triple pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 32A

Supply of miniature circuit breaker (MCB) triple pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 40A

Supply of miniature circuit breaker (MCB) triple pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 50A

Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A

Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A

Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 50A

Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A

Supply of miniature circuit breaker (MCB) triple pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 20A

Supply of miniature circuit breaker (MCB) triple pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 25A

Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 20A

Supply of miniature circuit breaker (MCB) triple pole, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A

Page 203: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 204

Department of Engineering Services, MoWHS

GB0355

Coefficient for per each of GB0355

Code Description Quant Units MT5228 TPN MCB, 415 volt A.C - 63A 1 each

GB0365

Coefficient for per each of GB0365

Code Description Quant Units MT5263 4 pole MCB, 415 volt A.C - 20A 1 each

GB0366

Coefficient for per each of GB0366

Code Description Quant Units MT5264 4 pole MCB, 415 volt A.C - 25A 1 each

GB0367

Coefficient for per each of GB0367

Code Description Quant Units MT5265 4 pole MCB, 415 volt A.C - 32A 1 each

GB0368

Coefficient for per each of GB0368

Code Description Quant Units MT5266 4 pole MCB, 415 volt A.C - 40A 1 each

GB0369

Coefficient for per each of GB0369

Code Description Quant Units MT5267 4 pole MCB, 415 volt A.C - 50A 1 each

GB0370

Coefficient for per each of GB0370

Code Description Quant Units MT5268 4 pole MCB, 415 volt A.C - 63A 1 each

GB0380

Coefficient for per each of GB0380

Code Description Quant Units MT5301 DP Isolators, 230 volt A.C - 40A 1 each

GB0381

Coefficient for per each of GB0381

Code Description Quant Units MT5302 DP Isolators, 230 volt A.C - 63A 1 each

GB0395

Coefficient for per each of GB0395

Code Description Quant Units MT5321 TP Isolators, 415 volt A.C - 40A 1 each

GB0396

Coefficient for per each of GB0396

Code Description Quant Units MT5322 TP Isolators, 415 volt A.C - 63A 1 each

Supply of loadkontak isolator triple pole, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 40A

Supply of loadkontak isolator triple pole, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 63A

Supply of miniature circuit breaker (MCB) 4 pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 32A

Supply of miniature circuit breaker (MCB) 4 pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 40A

Supply of miniature circuit breaker (MCB) 4 pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 50A

Supply of miniature circuit breaker (MCB) 4 pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 63A

Supply of loadkontak isolator double pole, 230 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 40A

Supply of loadkontak isolator double pole, 230 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 63A

Supply of miniature circuit breaker (MCB) triple pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 63A

Supply of miniature circuit breaker (MCB) 4 pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 20A

Supply of miniature circuit breaker (MCB) 4 pole & neutral, 415 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 25A

Page 204: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 205

Department of Engineering Services, MoWHS

GB0410

Coefficient for per each of GB0410

Code Description Quant Units MT5340 DP Timer switch , 230 volt A.C - 24hrs/24hrs 1 each

GB0411

Coefficient for per each of GB0411

Code Description Quant Units MT5341 DP Timer switch , 230 volt A.C - 7days/24hrs 1 each

GB0425

Coefficient for per each of GB0425

Code Description Quant Units MT5350 2 pole RCCB, 230 volt A.C, 30mA - 16A 1 each

GB0426

Coefficient for per each of GB0426

Code Description Quant Units MT5351 2 pole RCCB, 230 volt A.C, 30mA - 25A 1 each

GB0427

Coefficient for per each of GB0427

Code Description Quant Units MT5352 2 pole RCCB, 230 volt A.C, 30mA - 32A 1 each

GB0428

Coefficient for per each of GB0428

Code Description Quant Units MT5353 2 pole RCCB, 230 volt A.C, 30mA - 40A 1 each

GB0429

Coefficient for per each of GB0429

Code Description Quant Units MT5354 2 pole RCCB, 230 volt A.C, 30mA - 63A 1 each

GB0440

Coefficient for per each of GB0440

Code Description Quant Units MT5380 2 pole RCCB, 230 volt A.C, 100mA - 16A 1 each

GB0441

Coefficient for per each of GB0441

Code Description Quant Units MT5381 2 pole RCCB, 230 volt A.C, 100mA - 25A 1 each

GB0442

Coefficient for per each of GB0442

Code Description Quant Units MT5382 2 pole RCCB, 230 volt A.C, 100mA - 32A 1 each

GB0443

Coefficient for per each of GB0443

Code Description Quant Units MT5383 2 pole RCCB, 230 volt A.C, 100mA - 40A 1 each

Supply of residual current circuit breaker (RCCB) double pole, sensitivity 100mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A

Supply of residual current circuit breaker (RCCB) double pole, sensitivity 30mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A

Supply of residual current circuit breaker (RCCB) double pole, sensitivity 30mA, 230 volt A.C complete with all accessories suitable tofix on a din-bar etc. as required - 40A

Supply of residual current circuit breaker (RCCB) double pole, sensitivity 30mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A

Supply of residual current circuit breaker (RCCB) double pole, sensitivity 100mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A

Supply of residual current circuit breaker (RCCB) double pole, sensitivity 100mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A

Supply of residual current circuit breaker (RCCB) double pole, sensitivity 100mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A

Supply of electronic timer switch double pole, 50Hz, sensitivity 30mA, 230 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 24hrs/24hrs

Supply of electronic timer switch double pole, 50Hz, sensitivity 30mA, 230 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 7days/24hrs

Supply of residual current circuit breaker (RCCB) double pole, sensitivity 30mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A

Supply of residual current circuit breaker (RCCB) double pole, sensitivity 30mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A

Page 205: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 206

Department of Engineering Services, MoWHS

GB0444

Coefficient for per each of GB0444

Code Description Quant Units MT5384 2 pole RCCB, 230 volt A.C, 100mA - 63A 1 each

GB0455

Coefficient for per each of GB0455

Code Description Quant Units MT5410 2 pole RCCB, 230 volt A.C, 300mA - 16A 1 each

GB0456

Coefficient for per each of GB0456

Code Description Quant Units MT5411 2 pole RCCB, 230 volt A.C, 300mA - 25A 1 each

GB0457

Coefficient for per each of GB0457

Code Description Quant Units MT5412 2 pole RCCB, 230 volt A.C, 300mA - 32A 1 each

GB0458

Coefficient for per each of GB0458

Code Description Quant Units MT5413 2 pole RCCB, 230 volt A.C, 300mA - 40A 1 each

GB0459

Coefficient for per each of GB0459

Code Description Quant Units MT5414 2 pole RCCB, 230 volt A.C, 300mA - 63A 1 each

GB0470

Coefficient for per each of GB0470

Code Description Quant Units MT5440 4 pole RCCB, 415 volt A.C, 30mA - 16A 1 each

GB0471

Coefficient for per each of GB0471

Code Description Quant Units MT5441 4 pole RCCB, 415 volt A.C, 30mA - 25A 1 each

GB0472

Coefficient for per each of GB0472

Code Description Quant Units MT5442 4 pole RCCB, 415 volt A.C, 30mA - 32A 1 each

GB0473

Coefficient for per each of GB0473

Code Description Quant Units MT5443 4 pole RCCB, 415 volt A.C, 30mA - 40A 1 each

GB0474

Coefficient for per each of GB0474

Code Description Quant Units MT5444 4 pole RCCB, 415 volt A.C, 30mA - 63A 1 each

Supply of residual current circuit breaker (RCCB) double pole, sensitivity 300mA, 230 volt A.C complete with all accessories suitable to to fix on a din-bar etc. as required - 63A

Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 30mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A

Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 30mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A

Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 30mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A

Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 30mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A

Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 30mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A

Supply of residual current circuit breaker (RCCB) double pole, sensitivity 100mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A

Supply of residual current circuit breaker (RCCB) double pole, sensitivity 300mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A

Supply of residual current circuit breaker (RCCB) double pole, sensitivity 300mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A

Supply of residual current circuit breaker (RCCB) double pole, sensitivity 300mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A

Supply of residual current circuit breaker (RCCB) double pole, sensitivity 300mA, 230 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A

Page 206: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 207

Department of Engineering Services, MoWHS

GB0485

Coefficient for per each of GB0485

Code Description Quant Units MT5470 4 pole RCCB, 415 volt A.C, 100mA - 16A 1 each

GB0486

Coefficient for per each of GB0486

Code Description Quant Units MT5471 4 pole RCCB, 415 volt A.C, 100mA - 25A 1 each

GB0487

Coefficient for per each of GB0487

Code Description Quant Units MT5472 4 pole RCCB, 415 volt A.C, 100mA - 32A 1 each

GB0488

Coefficient for per each of GB0488

Code Description Quant Units MT5473 4 pole RCCB, 415 volt A.C, 100mA - 40A 1 each

GB0489

Coefficient for per each of GB0489

Code Description Quant Units MT5474 4 pole RCCB, 415 volt A.C, 100mA - 63A 1 each

GB0500

Coefficient for per each of GB0500

Code Description Quant Units MT5500 4 pole RCCB, 415 volt A.C, 300mA - 16A 1 each

GB0501

Coefficient for per each of GB0501

Code Description Quant Units MT5501 4 pole RCCB, 415 volt A.C, 300mA - 25A 1 each

GB0502

Coefficient for per each of GB0502

Code Description Quant Units MT5502 4 pole RCCB, 415 volt A.C, 300mA - 32A 1 each

GB0503

Coefficient for per each of GB0503

Code Description Quant Units MT5503 4 pole RCCB, 415 volt A.C, 300mA - 40A 1 each

GB0504

Coefficient for per each of GB0504

Code Description Quant Units MT5504 4 pole RCCB, 415 volt A.C, 300mA - 63A 1 each

Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 300mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A

Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 300mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A

Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 300mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A

Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 300mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A

Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 100mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A

Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 100mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 25A

Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 100mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 32A

Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 100mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 40A

Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 100mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 63A

Supply of residual current circuit breaker (RCCB) 4 pole, sensitivity 300mA, 415 volt A.C complete with all accessories suitable to fix on a din-bar etc. as required - 16A

Page 207: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 208

Department of Engineering Services, MoWHS

GB0515

Coefficient for per each of GB0515

Code Description Quant Units MT5525 SPN DB, 230 volt A.C, without door - 4 way 1 each

GB0516

Coefficient for per each of GB0516

Code Description Quant Units MT5526 SPN DB, 230 volt A.C, without door - 6 way 1 each

GB0517

Coefficient for per each of GB0517

Code Description Quant Units MT5527 SPN DB, 230 volt A.C, without door - 8 way 1 each

GB0518

Coefficient for per each of GB0518

Code Description Quant Units MT5528 SPN DB, 230 volt A.C, without door - 12 way 1 each

GB0519

Coefficient for per each of GB0519

Code Description Quant Units MT5529 SPN DB, 230 volt A.C, without door - 16 way 1 each

GB0521

Coefficient for per each of GB0521

Code Description Quant Units MT5531 SPN DB, 230 volt A.C, with metal door - 4 way 1 each

GB0522

Coefficient for per each of GB0522

Code Description Quant Units MT5532 SPN DB, 230 volt A.C, with metal door - 6 way 1 each

GB0523

Coefficient for per each of GB0523

Code Description Quant Units MT5533 SPN DB, 230 volt A.C, with metal door - 8 way 1 each

GB0524

Coefficient for per each of GB0524

Code Description Quant Units MT5534 SPN DB, 230 volt A.C, with metal door - 12 way 1 each

GB0525

Coefficient for per each of GB0525

Code Description Quant Units MT5535 SPN DB, 230 volt A.C, with metal door - 16 way 1 each

Supply of SPN distribution board (DIN type) with metal door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way

Supply of SPN distribution board (DIN type) with metal door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way

Supply of SPN distribution board (DIN type) with metal door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way

Supply of SPN distribution board (DIN type) with metal door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way

Supply of SPN distribution board (DIN type) with metal door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 16 way

Supply of SPN distribution board (DIN type) without door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way

Supply of SPN distribution board (DIN type) without door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way

Supply of SPN distribution board (DIN type) without door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way

Supply of SPN distribution board (DIN type) without door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way

Supply of SPN distribution board (DIN type) without door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 16 way

Page 208: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 209

Department of Engineering Services, MoWHS

GB0527

Coefficient for per each of GB0527

Code Description Quant Units MT5537 SPN DB, 230 volt A.C, with arcylic door - 4 way 1 each

GB0528

Coefficient for per each of GB0528

Code Description Quant Units MT5538 SPN DB, 230 volt A.C, with arcylic door - 6 way 1 each

GB0529

Coefficient for per each of GB0529

Code Description Quant Units MT5539 SPN DB, 230 volt A.C, with arcylic door - 8 way 1 each

GB0530

Coefficient for per each of GB0530

Code Description Quant Units MT5540 SPN DB, 230 volt A.C, with arcylic door - 12 way 1 each

GB0531

Coefficient for per each of GB0531

Code Description Quant Units MT5541 SPN DB, 230 volt A.C, with arcylic door - 16 way 1 each

GB0533

Coefficient for per each of GB0533

Code Description Quant Units MT5543 TPN DB, 415 volt A.C, horizontal, without door - 4 way 1 each

GB0534

Coefficient for per each of GB0534

Code Description Quant Units MT5544 TPN DB, 415 volt A.C, horizontal, without door - 6 way 1 each

GB0535

Coefficient for per each of GB0535

Code Description Quant Units MT5545 TPN DB, 415 volt A.C, horizontal, without door - 8 way 1 each

GB0536

Coefficient for per each of GB0536

Code Description Quant Units MT5546 TPN DB, 415 volt A.C, horizontal, without door - 12 way 1 each

Supply of TPN distribution board (DIN type, horizontal) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way

Supply of TPN distribution board (DIN type, horizontal) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way

Supply of SPN distribution board (DIN type) with arcylic door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way

Supply of SPN distribution board (DIN type) with arcylic door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way

Supply of SPN distribution board (DIN type) with arcylic door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way

Supply of SPN distribution board (DIN type) with arcylic door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 16 way

Supply of TPN distribution board (DIN type, horizontal) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way

Supply of TPN distribution board (DIN type, horizontal) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way

Supply of SPN distribution board (DIN type) with arcylic door, 230 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way

Page 209: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 210

Department of Engineering Services, MoWHS

GB0537

Coefficient for per each of GB0537

Code Description Quant Units MT5547 TPN DB, 415 volt A.C, horizontal, without door - 16 way 1 each

GB0539

Coefficient for per each of GB0539

Code Description Quant Units MT5549 TPN DB, 415 volt A.C, horizontal, with metal door - 4 way 1 each

GB0540

Coefficient for per each of GB0540

Code Description Quant Units MT5550 TPN DB, 415 volt A.C, horizontal, with metal door - 6 way 1 each

GB0541

Coefficient for per each of GB0541

Code Description Quant Units MT5551 TPN DB, 415 volt A.C, horizontal, with metal door - 8 way 1 each

GB0542

Coefficient for per each of GB0542

Code Description Quant Units MT5552 TPN DB, 415 volt A.C, horizontal, with metal door - 12 way 1 each

GB0543

Coefficient for per each of GB0543

Code Description Quant Units MT5553 TPN DB, 415 volt A.C, horizontal, with metal door - 16 way 1 each

GB0545

Coefficient for per each of GB0545

Code Description Quant Units MT5555 TPN DB, 415 volt A.C, horizontal, with arcylic door - 4 way 1 each

GB0546

Coefficient for per each of GB0546

Code Description Quant Units MT5556 TPN DB, 415 volt A.C, horizontal, with arcylic door - 6 way 1 each

Supply of TPN distribution board (DIN type, horizontal) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 16 way

Supply of TPN distribution board (DIN type, horizontal) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way

Supply of TPN distribution board (DIN type, horizontal) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way

Supply of TPN distribution board (DIN type, horizontal) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way

Supply of TPN distribution board (DIN type, horizontal) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way

Supply of TPN distribution board (DIN type, horizontal) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way

Supply of TPN distribution board (DIN type, horizontal) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 16 way

Supply of TPN distribution board (DIN type, horizontal) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way

Page 210: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 211

Department of Engineering Services, MoWHS

GB0547

Coefficient for per each of GB0547

Code Description Quant Units MT5557 TPN DB, 415 volt A.C, horizontal, with arcylic door - 8 way 1 each

GB0548

Coefficient for per each of GB0548

Code Description Quant Units MT5558 TPN DB, 415 volt A.C, horizontal, with arcylic door - 12 way 1 each

GB0549

Coefficient for per each of GB0549

Code Description Quant Units MT5559 TPN DB, 415 volt A.C, horizontal, with arcylic door - 16 way 1 each

GB0551

Coefficient for per each of GB0551

Code Description Quant Units MT5561 TPN DB, 415 volt A.C, vertical, without door - 4 way 1 each

GB0552

Coefficient for per each of GB0552

Code Description Quant Units MT5562 TPN DB, 415 volt A.C, vertical, without door - 6 way 1 each

GB0553

Coefficient for per each of GB0553

Code Description Quant Units MT5563 TPN DB, 415 volt A.C, vertical, without door - 8 way 1 each

GB0554

Coefficient for per each of GB0554

Code Description Quant Units MT5564 TPN DB, 415 volt A.C, vertical, without door - 12 way 1 each

GB0556

Coefficient for per each of GB0556

Code Description Quant Units MT5566 TPN DB, 415 volt A.C, vertical, with metal door - 4 way 1 each

Supply of TPN distribution board (DIN type, vertical) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way

Supply of TPN distribution board (DIN type, vertical) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way

Supply of TPN distribution board (DIN type, vertical) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way

Supply of TPN distribution board (DIN type, vertical) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way

Supply of TPN distribution board (DIN type, vertical) without door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way

Supply of TPN distribution board (DIN type, horizontal) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way

Supply of TPN distribution board (DIN type, horizontal) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way

Supply of TPN distribution board (DIN type, horizontal) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 16 way

Page 211: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 212

Department of Engineering Services, MoWHS

GB0557

Coefficient for per each of GB0557

Code Description Quant Units MT5567 TPN DB, 415 volt A.C, vertical, with metal door - 6 way 1 each

GB0558

Coefficient for per each of GB0558

Code Description Quant Units MT5568 TPN DB, 415 volt A.C, vertical, with metal door - 8 way 1 each

GB0559

Coefficient for per each of GB0559

Code Description Quant Units MT5569 TPN DB, 415 volt A.C, vertical, with metal door - 12 way 1 each

GB0561

Coefficient for per each of GB0561

Code Description Quant Units MT5571 TPN DB, 415 volt A.C, vertical, with arcylic door - 4 way 1 each

GB0562

Coefficient for per each of GB0562

Code Description Quant Units MT5572 TPN DB, 415 volt A.C, vertical, with arcylic door - 6 way 1 each

GB0563

Coefficient for per each of GB0563

Code Description Quant Units MT5573 TPN DB, 415 volt A.C, vertical, with arcylic door - 8 way 1 each

GB0564

Coefficient for per each of GB0564

Code Description Quant Units MT5574 TPN DB, 415 volt A.C, vertical, with arcylic door - 12 way 1 each

GB0575

Coefficient for per each of GB0575

Code Description Quant Units MT5116 SPN MCB, 230 volt A.C - 10A 1 each MT5610 Earth plug & Socket, DP 230 volt A.C - 10A 1 each

GB0576

Coefficient for per each of GB0576

Code Description Quant Units MT5118 SPN MCB, 230 volt A.C - 20A 1 each MT5611 Earth plug & Socket, DP 230 volt A.C - 20A 1 each

Supply of TPN distribution board (DIN type, vertical) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way

Supply of TPN distribution board (DIN type, vertical) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way

Supply of TPN distribution board (DIN type, vertical) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 4 way

Supply of TPN distribution board (DIN type, vertical) with arcylic door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way

Supply of TPN distribution board (DIN type, vertical) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 6 way

Supply of TPN distribution board (DIN type, vertical) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 8 way

Supply of TPN distribution board (DIN type, vertical) with metal door, 415 volt A.C complete with all accessories without MCB/isolator/RCCB out going or incoming etc. as required - 12 way

Supply of double pole metal clad commercial/industrial type plug & socket outlet with earth terminal and incoming control gear MCB etc. as required , 230 volt A.C - 10A

Supply of double pole metal clad commercial/industrial type plug & socket outlet with earth terminal and incoming control gear MCB etc. as required , 230 volt A.C - 20A

Page 212: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 213

Department of Engineering Services, MoWHS

GB0590

Coefficient for per each of GB0590

Code Description Quant Units MT5263 4 pole MCB, 415 volt A.C - 20A 1 each MT5620 Earth plug & Socket, 4 pole 415 volt A.C - 20A 1 each

GB0591

Coefficient for per each of GB0591

Code Description Quant Units MT5265 4 pole MCB, 415 volt A.C - 32A 1 each MT5621 Earth plug & Socket, 4 pole 415 volt A.C - 32A 1 each

GB0592

Coefficient for per each of GB0592

Code Description Quant Units MT5268 4 pole MCB, 415 volt A.C - 63A 1 each MT5622 Earth plug & Socket, 4 pole 415 volt A.C - 63A 1 each

CHAPTER 15: ERECTION/INSTALLATION

Coefficient for per each of EI0001

Code Description Quant Units LB0056 Wireman Gd.1 0.056 day LB0069 Wireman Gd.2 0.056 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.5 m

Coefficient for per each of EI0002

Code Description Quant Units LB0056 Wireman Gd.1 0.056 day LB0069 Wireman Gd.2 0.056 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 0.5 m

Coefficient for per each of EI0015

Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.5 m

1.5 sq.mm single core cable 1.1 KV grade Coefficient for per each of EI0016

Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 0.5 m

Erection of all indoor recessed type ceiling fittings/ wall fittings, GLS lamps, fixing of lamp, testing etc. as required including connection with PVC insulated copper conductor - 1 sq.mm single core cable 1.1 KV grade

EI0015

Erection of all indoor recessed type ceiling fittings/ wall fittings, GLS lamps, fixing of lamp, testing etc. as required including connection with PVC insulated copper conductor - EI0016

Supply of 4 pole metal clad commercial/industrial type plug & socket outlet with earth terminal and incoming control gear MCB etc. as required , 415 volt A.C - 63A

Erection of all indoor/outdoor surface type wall bracket (single or double)/ surface ceiling fittings GLS lamps/ bulk head GLS lamp /all types call bell / all type picture or mirror lighting luminiaries fittings with all accessories, fixing of lamp, testing etc. as required including connection with PVC insulated copper conductor - 1 sq.mm single core cable 1.1 KV grade

EI0001

Erection of all indoor/outdoor surface type wall bracket (single or double)/ surface ceiling fittings GLS lamps/ bulk head GLS lamp / all types call bell / all type picture or mirror lighting luminiaries fittings with all accessories, fixing of lamp, testing etc. as required including connection with PVC insulated copper conductor - 1.5 sq.mm single core cable 1.1 KV grade

EI0002

Supply of 4 pole metal clad commercial/industrial type plug & socket outlet with earth terminal and incoming control gear MCB etc. as required , 415 volt A.C - 32A

Supply of 4 pole metal clad commercial/industrial type plug & socket outlet with earth terminal and incoming control gear MCB etc. as required , 415 volt A.C - 20A

Page 213: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 214

Department of Engineering Services, MoWHS

EI0030

Coefficient for per each of EI0030

Code Description Quant Units LB0056 Wireman Gd.1 0.033 day LB0069 Wireman Gd.2 0.033 day

Coefficient for per each of EI0040

Code Description Quant Units LB0056 Wireman Gd.1 0.167 day LB0069 Wireman Gd.2 0.167 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.5 m

Coefficient for per each of EI0040

Code Description Quant Units LB0056 Wireman Gd.1 0.167 day LB0069 Wireman Gd.2 0.167 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 0.5 m

Coefficient for per each of EI0055

Code Description Quant Units LB0051 Mason Gd.2 0.167 day LB0056 Wireman Gd.1 0.167 day LB0067 Painter Gd.2 0.0417 day LB0069 Wireman Gd.2 0.375 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.9 m MT4801 M.S Coduit - 20mm x 1.6mm 0.6 m MT4891 Wooden batten - Round block 76x38mm 2 each

Coefficient for per each of EI0056

Code Description Quant Units LB0051 Mason Gd.2 0.167 day LB0056 Wireman Gd.1 0.167 day LB0067 Painter Gd.2 0.0417 day LB0069 Wireman Gd.2 0.375 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 0.9 m MT4801 M.S Coduit - 20mm x 1.6mm 0.6 m MT4891 Wooden batten - Round block 76x38mm 2 each

Installation, testing and commissioning of prewired fluorescent fittings of all pendant type complete with all accessories and tubes including supplying and fixing ball and socket arrangement suspension down rod of 19mm dia 18 SWG MS conduit upto 300mm length, painting and including wiring down rod with PVC insulated copper conductor - 1 sq.mm single core cable 1.1 KV grade

EI0055

Installation, testing and commissioning of prewired fluorescent fittings of all pendant type complete with all accessories and tubes including supplying and fixing ball and socket arrangement suspension down rod of 19mm dia 18 SWG MS conduit upto 300mm length, painting and including wiring down rod with PVC insulated copper conductor - 1.5 sq.mm single core cable 1.1 KV grade

EI0056

Installation, testing and commissioning of prewired fluorescent fittings of all surface type complete with all accessories and tubes directly on ceiling/wall as required including connection with PVC insulated copper conductor - 1 sq.mm single core cable 1.1 KV grade

EI0040

Installation, testing and commissioning of prewired fluorescent fittings of all surface type complete with all accessories and tubes directly on ceiling/wall as required including connection with PVC insulated copper conductor - 1.5 sq.mm single core cable 1.1 KV grade

EI0041

Erection / replacement for surface or recessed GLS luminiaries to make good as required - All types glass globe / shade

Page 214: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 215

Department of Engineering Services, MoWHS

EI0070

Coefficient for per each of EI0070

Code Description Quant Units LB0056 Wireman Gd.1 0.0167 day LB0069 Wireman Gd.2 0.0167 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.2 m MT4801 M.S Coduit - 20mm x 1.6mm 0.2 m

1 sq.mm single core cable 1.1 KV grade Coefficient for per each of EI0080

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.255 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.5 m

1.5 sq.mm single core cable 1.1 KV grade Coefficient for per each of EI0081

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 0.5 m

Coefficient for per each of EI0095

Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.8 m

Coefficient for per each of EI0096

Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 0.8 m

EI0110

Coefficient for per each of EI0110

Code Description Quant Units LB0051 Mason Gd.2 0.0104 day LB0056 Wireman Gd.1 0.0104 day LB0067 Painter Gd.2 0.0071 day LB0069 Wireman Gd.2 0.028 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.2 m MT6665 G.I Pipe heavy duty - 15mm 0.1 m

1.1 KV grade EI0095

Installation, testing and commissioning of all size ceiling fan and regulator including wiring the down rod of standard length upto 300mm with PVC insulated copper conductor - 1.5 sq.mm single core cable 1.1 KV grade

EI0096

Supplying extra down rod of G.I Pipe (heavy duty) with 2x1 sq.mm PVC insulated single core copper conductor cable, painting, cutting, and threading etc. as required - 15mm dia, 100 mm long

Providing extra down rod with 2x1 sq.mm PVC insulated single core copper conductor cable including painting as required - 20mm dia, 2x100 mm long

Installation, testing and commissioning of prewired fluorescent fittings of all recessed type complete with all accessories and tubes on ceiling including connection with PVC insulated copper conductor-EI0080

Installation, testing and commissioning of prewired fluorescent fittings of all recessed type complete with all accessories and tubes on ceiling including connection with PVC insulated copper conductor - EI0081

Installation, testing and commissioning of all size ceiling fan and regulator including wiring the down rod of standard length upto 300mm with PVC insulated copper conductor - 1 sq.mm single core cable

Page 215: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 216

Department of Engineering Services, MoWHS

Coefficient for per each of EI0120

Code Description Quant Units LB0051 Mason Gd.2 0.33 day LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.67 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.8 m

Coefficient for per each of EI0121

Code Description Quant Units LB0051 Mason Gd.2 0.33 day LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.67 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 0.8 m

Coefficient for per each of EI0135

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1 day MT4070 PVC insulated Single Core Copper conductor (1.1KV) - 1 sq.mm 0.8 m

Coefficient for per each of EI0136

Code Description Quant Units LB0051 Mason Gd.2 0.5 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 1 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 0.8 m

EI0150

Coefficient for per each of EI0150

Code Description Quant Units LB0051 Mason Gd.2 0.125 day LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.2 day EI0160 Coefficient for per each of EI0160

Code Description Quant Units LB0067 Painter Gd.2 0.03 day LB0069 Wireman Gd.2 0.03 day MT6682 Synthetic enamel paint 1 litre

Installation of aluminium louveres/shutters complete with a frame of all sizes in the existing opening including making good as required - Exhaust fan upto 510mm sweep

Numbering of ceiling or exhaust fan as required - Upto 510mm sweep

Installation, testing and commissioning of exhaust fan upto 510mm sweepin the existing opening including making the hole to suit the size of the indicated fan making good the damages, and connection with PVC insulated copper conductor - 1 sq.mm single core cable 1.1 KV grade

EI0135

Installation, testing and commissioning of exhaust fan upto 510mm sweepin the existing opening including making the hole to suit the size of the indicated fan making good the damages, and connection with PVC insulated copper conductor - 1.5 sq.mm single core cable 1.1 KV grade

EI0136

Installation, testing and commissioning of exhaust fan upto 450mm sweepin the existing opening including making the hole to suit the size of the indicated fan making good the damages, and connection with PVC insulated copper conductor - 1 sq.mm single core cable 1.1 KV grade

EI0120

Installation, testing and commissioning of exhaust fan upto 450mm sweepin the existing opening including making the hole to suit the size of the indicated fan making good the damages, and connection with PVC insulated copper conductor - 1.5 sq.mm single core cable 1.1 KV grade

EI0121

Page 216: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 217

Department of Engineering Services, MoWHS

EI0170

Coefficient for per each of EI0170

Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 3 m MT4079 PVC insulated Single Core Copper conductor (1.1KV) - 35 sq.mm 2 m MT4640 Flat type Brass Thimble - 63A 4 each MT4641 Flat type Brass Thimble - 100A 2 each MT4843 PVC Conduit - 40 mm,14SWG 0.6 m MT4844 PVC Conduit - 50 mm,14SWG 0.3 m

EI0171

Coefficient for per each of EI0171

Code Description Quant Units LB0056 Wireman Gd.1 1 day LB0069 Wireman Gd.2 1 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 4 m MT4079 PVC insulated Single Core Copper conductor (1.1KV) - 35 sq.mm 3 m MT4640 Flat type Brass Thimble - 63A 4 each MT4641 Flat type Brass Thimble - 100A 2 each MT4844 PVC Conduit - 50 mm,14SWG 1 m

EI0172

Coefficient for per each of EI0172

Code Description Quant Units LB0056 Wireman Gd.1 1.25 day LB0069 Wireman Gd.2 1.25 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 13 m MT4079 PVC insulated Single Core Copper conductor (1.1KV) - 35 sq.mm 3 m MT4640 Flat type Brass Thimble - 63A 16 each MT4641 Flat type Brass Thimble - 100A 4 each MT4844 PVC Conduit - 50 mm,14SWG 3 m

EI0173

Coefficient for per each of EI0173

Code Description Quant Units LB0056 Wireman Gd.1 1.25 day LB0069 Wireman Gd.2 1.25 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 13 m MT4081 PVC insulated Single Core Copper conductor (1.1KV) - 70 sq.mm 3 m MT4640 Flat type Brass Thimble - 63A 16 each MT4642 Flat type Brass Thimble - 200A 4 each MT4844 PVC Conduit - 50 mm,14SWG 3 m

Installation, testing and commissioning of prefabricated bus bar chamber with copper bus bar complete with all accessories including connections etc. as required - 2 strips, 300/450mm length, 100A

Installation, testing and commissioning of prefabricated bus bar chamber with copper bus bar complete with all accessories including connections etc. as required - 4 strips, 300/450mm length, 100A

Installation, testing and commissioning of prefabricated bus bar chamber with copper bus bar complete with all accessories including connections etc. as required - 4 strips, 600mm length, 100A

Installation, testing and commissioning of prefabricated bus bar chamber with copper bus bar complete with all accessories including connections etc. as required - 4 strips, 300/450mm length, 200A

Page 217: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 218

Department of Engineering Services, MoWHS

EI0174

Coefficient for per each of EI0174

Code Description Quant Units LB0056 Wireman Gd.1 1.5 day LB0069 Wireman Gd.2 1.5 day MT4077 PVC insulated Single Core Copper conductor (1.1KV) - 16 sq.mm 13 m MT4081 PVC insulated Single Core Copper conductor (1.1KV) - 70 sq.mm 3 m MT4640 Flat type Brass Thimble - 63A 16 each MT4642 Flat type Brass Thimble - 200A 4 each MT4844 PVC Conduit - 50 mm,14SWG 4 m

Coefficient for per each of EI0185

Code Description Quant Units LB0056 Wireman Gd.1 1.7 day LB0069 Wireman Gd.2 1.7 day MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 15 m MT4056 PVC insulated single core Aluminium conductor cable 1.1KV - 185 sq.mm 3 m MT4655 Flat type Aluminium Alloy Thimble - 100A 16 each MT4658 Flat type Aluminium Alloy Thimble - 300A 4 each MT4844 PVC Conduit - 50 mm,14SWG 6 m

Coefficient for per each of EI0186

Code Description Quant Units LB0056 Wireman Gd.1 1.85 day LB0069 Wireman Gd.2 1.85 day MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 20 m MT4057 PVC insulated single core Aluminium conductor cable 1.1KV - 300 sq.mm 3 m MT4655 Flat type Aluminium Alloy Thimble - 100A 24 each MT4660 Flat type Aluminium Alloy Thimble - 400A 4 each MT4844 PVC Conduit - 50 mm,14SWG 8 m

Coefficient for per each of EI0187

Code Description Quant Units LB0056 Wireman Gd.1 2 day LB0069 Wireman Gd.2 2 day MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 20 m MT4058 PVC insulated single core Aluminium conductor cable 1.1KV - 600 sq.mm 3 m MT4655 Flat type Aluminium Alloy Thimble - 100A 24 each MT4662 Flat type Aluminium Alloy Thimble - 600A 4 each MT4844 PVC Conduit - 50 mm,14SWG 8 m

Coefficient for per each of EI0188

Code Description Quant Units LB0056 Wireman Gd.1 1.95 day LB0069 Wireman Gd.2 1.95 day

Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete with all accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 600mm length, 600A

EI0187

Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete with all accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 900mm length, 400A

EI0188

Installation, testing and commissioning of prefabricated bus bar chamber with copper bus bar complete with all accessories including connections etc. as required - 4 strips, 600mm length, 200A

Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete all with accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 600mm length, 300A

EI0185

Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete with all accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 600mm length, 400A

EI0186

Page 218: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 219

Department of Engineering Services, MoWHS

MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 22 m MT4057 PVC insulated single core Aluminium conductor cable 1.1KV - 300 sq.mm 3.5 m MT4655 Flat type Aluminium Alloy Thimble - 100A 24 each MT4660 Flat type Aluminium Alloy Thimble - 400A 4 each MT4844 PVC Conduit - 50 mm,14SWG 9 m

Coefficient for per each of EI0189

Code Description Quant Units LB0056 Wireman Gd.1 2.2 day LB0069 Wireman Gd.2 2.2 day MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 22 m MT4058 PVC insulated single core Aluminium conductor cable 1.1KV - 600 sq.mm 3.5 m MT4655 Flat type Aluminium Alloy Thimble - 100A 24 each MT4662 Flat type Aluminium Alloy Thimble - 600A 4 each MT4844 PVC Conduit - 50 mm,14SWG 9 m

Coefficient for per each of EI0190

Code Description Quant Units LB0056 Wireman Gd.1 2.5 day LB0069 Wireman Gd.2 2.5 day MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 25 m MT4059 PVC insulated single core Aluminium conductor cable 1.1KV - 800 sq.mm 3.5 m MT4655 Flat type Aluminium Alloy Thimble - 100A 32 each MT4665 Flat type Aluminium Alloy Thimble - 800A 4 each MT4844 PVC Conduit - 50 mm,14SWG 10 m

Coefficient for per each of EI0191

Code Description Quant Units LB0056 Wireman Gd.1 2 day LB0069 Wireman Gd.2 2 day MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 24 m MT4057 PVC insulated single core Aluminium conductor cable 1.1KV - 300 sq.mm 4 m MT4655 Flat type Aluminium Alloy Thimble - 100A 24 each MT4660 Flat type Aluminium Alloy Thimble - 400A 4 each MT4844 PVC Conduit - 50 mm,14SWG 9 m

Coefficient for per each of EI0192

Code Description Quant Units LB0056 Wireman Gd.1 2.4 day LB0069 Wireman Gd.2 2.4 day MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 24 m MT4058 PVC insulated single core Aluminium conductor cable 1.1KV - 600 sq.mm 4 m MT4655 Flat type Aluminium Alloy Thimble - 100A 24 each MT4662 Flat type Aluminium Alloy Thimble - 600A 4 each MT4844 PVC Conduit - 50 mm,14SWG 9 m

Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete with all accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 1350mm length, 400A

EI0191

Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete with all accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 1350mm length, 600A

EI0192

Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete with all accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 900mm length, 600A

EI0189

Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete with all accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 900mm length, 800A

EI0190

Page 219: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 220

Department of Engineering Services, MoWHS

Coefficient for per each of EI0193

Code Description Quant Units LB0056 Wireman Gd.1 2.7 day LB0069 Wireman Gd.2 2.7 day MT4055 PVC insulated single core Aluminium conductor cable 1.1KV - 35 sq.mm 24 m MT4059 PVC insulated single core Aluminium conductor cable 1.1KV - 800 sq.mm 4 m MT4655 Flat type Aluminium Alloy Thimble - 100A 32 each MT4665 Flat type Aluminium Alloy Thimble - 800A 4 each MT4844 PVC Conduit - 50 mm,14SWG 11 m

Coefficient for per each of EI0205

Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4678 Ferrule type brass thimble - 20A 4 each

Coefficient for per each of EI0206

Code Description Quant Units LB0056 Wireman Gd.1 0.11 day LB0069 Wireman Gd.2 0.11 day MT4680 Ferrule type brass thimble - 32A 4 each

Coefficient for per each of EI0207

Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4683 Ferrule type brass thimble - 63A 4 each

Coefficient for per each of EI0220

Code Description Quant Units LB0056 Wireman Gd.1 0.1428 day LB0069 Wireman Gd.2 0.1428 day MT4685 Ferrule type brass thimble - 125A 4 each

Coefficient for per each of EI0230

Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4680 Ferrule type brass thimble - 32A 4 each

Installation, testing and commissioning of TPN/four pole steel encloser/panel mounting front drive switch fuse unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 125A, 415V

EI0220

Installation, testing and commissioning of TP switch fuse unit front drive four/ miniature circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 32A, 415V

EI0230

Installation, testing and commissioning of TPN steel encloser switch fuse unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 32A, 415V

EI0206

Installation, testing and commissioning of TPN steel encloser switch fuse unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 63A, 415V

EI0207

Installation, testing and commissioning of aluminium alloy/ wrought aluminium bus bar complete with all accessories accessories to accomodate in prefabricated MS cubical control panel board including connections etc. as required - 4 strips, 1350mm length, 800A

EI0193

Installation, testing and commissioning of TPN steel encloser switch fuse unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 20A, 415V

EI0205

Page 220: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 221

Department of Engineering Services, MoWHS

Coefficient for per each of EI0240

Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4706 Ferrule type aluminium alloy thimble - 125A 4 each

Coefficient for per each of EI0250

Code Description Quant Units LB0056 Wireman Gd.1 1 day LB0069 Wireman Gd.2 1 day MT4665 Flat type Aluminium Alloy Thimble - 800A 4 each

Coefficient for per each of EI0260

Code Description Quant Units LB0056 Wireman Gd.1 0.11 day LB0069 Wireman Gd.2 0.11 day MT4640 Flat type Brass Thimble - 63A 4 each

Coefficient for per each of EI0270

Code Description Quant Units LB0056 Wireman Gd.1 0.167 day LB0069 Wireman Gd.2 0.167 day MT4686 Ferrule type brass thimble - 200A 4 each

Coefficient for per each of EI0271

Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4659 Flat type Aluminium Alloy Thimble - 315A 4 each

Coefficient for per each of EI0272

Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4661 Flat type Aluminium Alloy Thimble - 500A 4 each

Installation, testing and commissioning of TPN steel encloser fuse switch unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 315A, 415V

EI0271

Installation, testing and commissioning of TPN steel encloser fuse switch unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panelboard including drilling holes, connections etc. as required - 500A, 415V

EI0272

Installation, testing and commissioning of TP switch fuse unit front drive/ miniature circuit breaker/ moulded case circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. required - 63A, 415V

EI0260

Installation, testing and commissioning of TPN steel encloser fuse switch unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 200A, 415V

EI0270

Installation, testing and commissioning of TP switch fuse unit front drive/ moulded case circuit breaker (DIN type) breaking capacity 16/25K complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 415V

EI0240

Installation, testing and commissioning of TP switch fuse unit front drive/ miniature circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubicle control panel board including drilling holes, connections etc. as required - 800A, 415V

EI0250

Page 221: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 222

Department of Engineering Services, MoWHS

Coefficient for per each of EI0273

Code Description Quant Units LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 0.75 day MT4663 Flat type Aluminium Alloy Thimble - 630A 4 each

Coefficient for per each of EI0285

Code Description Quant Units LB0056 Wireman Gd.1 0.2 day LB0069 Wireman Gd.2 0.2 day MT4643 Flat type Brass Thimble - 250A 4 each

Coefficient for per each of EI0286

Code Description Quant Units LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4660 Flat type Aluminium Alloy Thimble - 400A 4 each

Coefficient for per each of EI0300

Code Description Quant Units LB0056 Wireman Gd.1 1 day LB0069 Wireman Gd.2 1 day MT4664 Flat type Aluminium Alloy Thimble - 750A 4 each

Coefficient for per each of EI0301

Code Description Quant Units LB0056 Wireman Gd.1 1 day LB0069 Wireman Gd.2 1 day MT4665 Flat type Aluminium Alloy Thimble - 800A 4 each

Coefficient for per each of EI0315

Code Description Quant Units LB0056 Wireman Gd.1 0.2 day LB0069 Wireman Gd.2 0.2 day MT4660 Flat type Aluminium Alloy Thimble - 400A 4 each

Installation, testing and commissioning of TPN steel encloser fuse switch unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 630A, 415V

EI0273

Installation, testing and commissioning of TPN/four pole steel encloser/panel mounting front drive fuse switch unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 250A, 415V

EI0285

Installation, testing and commissioning of TPN/four pole steel encloser/panel mounting front drive fuse switch unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 400A, 415V

EI0286

Installation, testing and commissioning of TPN/four pole steel encloser fuse switch unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 750A, 415V

EI0300

Installation, testing and commissioning of TPN/four pole steel encloser fuse switch unit complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 800A, 415V

EI0301

Installation, testing and commissioning of TP fuse switch fuse unit front drive complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 400A, 415V

EI0315

Page 222: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 223

Department of Engineering Services, MoWHS

Coefficient for per each of EI0325

Code Description Quant Units LB0056 Wireman Gd.1 0.1428 day LB0069 Wireman Gd.2 0.1428 day MT4657 Flat type Aluminium Alloy Thimble - 250A 4 each

Coefficient for per each of EI0335

Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4678 Ferrule type brass thimble - 20A 4 each

Coefficient for per each of EI0336

Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4679 Ferrule type brass thimble - 25A 4 each

Coefficient for per each of EI0337

Code Description Quant Units LB0056 Wireman Gd.1 0.11 day LB0069 Wireman Gd.2 0.11 day MT4680 Ferrule type brass thimble - 32A 4 each

Coefficient for per each of EI0338

Code Description Quant Units LB0056 Wireman Gd.1 0.11 day LB0069 Wireman Gd.2 0.11 day MT4681 Ferrule type brass thimble - 40A 4 each

Coefficient for per each of EI0339

Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4682 Ferrule type brass thimble - 50A 4 each

Installation, testing and commissioning of TP fuse switch unit/ moulded case circuit breaker (DIN type) breaking capacity 36K complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 250A, 415V

EI0325

Installation, testing and commissioning of TPN/four pole miniature circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel boardincluding drilling holes, connections etc. as required - 20A, 415V

EI0335

Installation, testing and commissioning of TPN/four pole miniature circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel boardincluding drilling holes, connections etc. as required - 25A, 415V

EI0336

Installation, testing and commissioning of TPN/four pole miniature circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 32A, 415V

EI0337

Installation, testing and commissioning of TPN/four pole miniature circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 40A, 415V

EI0338

Installation, testing and commissioning of TPN/four pole miniature circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 50A, 415V

EI0339

Page 223: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 224

Department of Engineering Services, MoWHS

Coefficient for per each of EI0340

Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4683 Ferrule type brass thimble - 50A 4 each

Coefficient for per each of EI0350

Code Description Quant Units LB0056 Wireman Gd.1 0.09 day LB0069 Wireman Gd.2 0.09 day MT4675 Ferrule type brass thimble - 6A 4 each

Coefficient for per each of EI0351

Code Description Quant Units LB0056 Wireman Gd.1 0.09 day LB0069 Wireman Gd.2 0.09 day MT4676 Ferrule type brass thimble - 10A 4 each

Coefficient for per each of EI0352

Code Description Quant Units LB0056 Wireman Gd.1 0.09 day LB0069 Wireman Gd.2 0.09 day MT4677 Ferrule type brass thimble - 16A 4 each

Coefficient for per each of EI0353

Code Description Quant Units LB0056 Wireman Gd.1 0.09 day LB0069 Wireman Gd.2 0.09 day MT4678 Ferrule type brass thimble - 20A 4 each

Coefficient for per each of EI0354

Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4679 Ferrule type brass thimble - 25A 4 each

Coefficient for per each of EI0355

Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4680 Ferrule type brass thimble - 32A 4 each

Installation, testing and commissioning of TPN/four pole miniature circuit breaker (DIN type) complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 63A, 415V

EI0340

Installation, testing and commissioning of TP miniature circuit breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 6A, 415V

EI0350

Installation, testing and commissioning of TP miniature circuit breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 10A, 415V

EI0351

Installation, testing and commissioning of TP miniature circuit breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 16A, 415V

EI0352

Installation, testing and commissioning of TP miniature circuit breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 20A, 415V

EI0353

Installation, testing and commissioning of TP miniature circuit breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 25A, 415V

EI0354

Installation, testing and commissioning of TP miniature circuit breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 32A, 415V

EI0355

Page 224: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 225

Department of Engineering Services, MoWHS

Coefficient for per each of EI0365

Code Description Quant Units LB0056 Wireman Gd.1 0.09 day LB0069 Wireman Gd.2 0.09 day MT4681 Ferrule type brass thimble - 40A 4 each

Coefficient for per each of EI0366

Code Description Quant Units LB0056 Wireman Gd.1 0.09 day LB0069 Wireman Gd.2 0.09 day MT4682 Ferrule type brass thimble - 50A 4 each

Coefficient for per each of EI0367

Code Description Quant Units LB0056 Wireman Gd.1 0.11 day LB0069 Wireman Gd.2 0.11 day MT4683 Ferrule type brass thimble - 63A 4 each

Coefficient for per each of EI0380

Code Description Quant Units LB0056 Wireman Gd.1 0.09 day LB0069 Wireman Gd.2 0.09 day MT4675 Ferrule type brass thimble - 6A 1 each MT4676 Ferrule type brass thimble - 10A 1 each MT4677 Ferrule type brass thimble - 16A 1 each MT4678 Ferrule type brass thimble - 20A 1 each

Coefficient for per each of EI0390

Code Description Quant Units LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.1 day MT4679 Ferrule type brass thimble - 25A 1.33 each MT4680 Ferrule type brass thimble - 32A 1.33 each MT4681 Ferrule type brass thimble - 40A 1.33 each

Coefficient for per each of EI0400

Code Description Quant Units LB0056 Wireman Gd.1 0.11 day LB0069 Wireman Gd.2 0.11 day MT4682 Ferrule type brass thimble - 50A 2 each MT4683 Ferrule type brass thimble - 63A 2 each

Installation, testing and commissioning of TP miniature circuit/ isolator breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 40A, 415V

EI0365

Installation, testing and commissioning of TP miniature circuit/ isolator breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 50A, 415V

EI0366

Installation, testing and commissioning of TP miniature circuit/ isolator breaker complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 63A, 415V

EI0367

drilling holes, connections etc. as required - 6/10/16/20A

Installation, testing and commissioning of SPN/DP miniature circuit breaker DIN type complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including EI0380

Installation, testing and commissioning of SPN/DP miniature circuit breaker DIN type complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 25/32/40A

EI0390

Installation, testing and commissioning of SPN/DP miniature circuit breaker/ isolator DIN type complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 50/63A

EI0400

Page 225: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 226

Department of Engineering Services, MoWHS

Coefficient for per each of EI0410

Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4702 Ferrule type aluminium alloy thimble - 50A 4 each

Coefficient for per each of EI0411

Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4703 Ferrule type aluminium alloy thimble - 63A 4 each

Coefficient for per each of EI0425

Code Description Quant Units LB0056 Wireman Gd.1 0.1428 day LB0069 Wireman Gd.2 0.1428 day MT4705 Ferrule type aluminium alloy thimble - 100A 4 each

Coefficient for per each of EI0426

Code Description Quant Units LB0056 Wireman Gd.1 0.1428 day LB0069 Wireman Gd.2 0.1428 day MT4706 Ferrule type aluminium alloy thimble - 125A 4 each

Coefficient for per each of EI0440

Code Description Quant Units LB0056 Wireman Gd.1 0.1667 day LB0069 Wireman Gd.2 0.1667 day MT4709 Ferrule type aluminium alloy thimble - 160A 4 each

Coefficient for per each of EI0450

Code Description Quant Units LB0056 Wireman Gd.1 0.2 day LB0069 Wireman Gd.2 0.2 day MT4657 Flat type Aluminium Alloy Thimble - 250A 4 each

Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 16/25K complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 50A, 415V

EI0410

Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 16/25K complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 63A, 415V

EI0411

Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 16/25/36K/earth leakage module complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as 100A, 415V

EI0425

Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 16/25/36K/earth leakage module complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as 125A, 415V

EI0426

Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 36K/earth leakage module complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as 160A, 415V

EI0440

Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 36/70K/earth leakage module complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as 250A, 415V

EI0450

Page 226: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 227

Department of Engineering Services, MoWHS

Coefficient for per each of EI0460

Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4660 Flat type Aluminium Alloy Thimble - 400A 4 each

Coefficient for per each of EI0461

Code Description Quant Units LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 0.75 day MT4663 Flat type Aluminium Alloy Thimble - 630A 4 each

Coefficient for per each of EI0475

Code Description Quant Units LB0056 Wireman Gd.1 1 day LB0069 Wireman Gd.2 1 day MT4665 Flat type Aluminium Alloy Thimble - 800A 4 each

Coefficient for per each of EI0485

Code Description Quant Units LB0056 Wireman Gd.1 0.1428 day LB0069 Wireman Gd.2 0.1428 day MT4709 Ferrule type aluminium alloy thimble - 160A 4 each

Coefficient for per each of EI0495

Code Description Quant Units LB0056 Wireman Gd.1 0.1742 day LB0069 Wireman Gd.2 0.1742 day MT4675 Ferrule type brass thimble - 6A 1.33 each MT4676 Ferrule type brass thimble - 10A 1.33 each MT4677 Ferrule type brass thimble - 16A 2.33 each MT4679 Ferrule type brass thimble - 25A 1 each

Coefficient for per each of EI0505

Code Description Quant Units LB0056 Wireman Gd.1 0.202 day LB0069 Wireman Gd.2 0.202 day

Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 70K/earth leakage module complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as 400A, 415V

EI0460

Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 70K/earth leakage module complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as 630A, 415V

EI0461

Installation, testing and commissioning of four pole moulded case circuit breaker (DIN type) breaking capacity 70K complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 800A, 415V

EI0475

Installation, testing and commissioning of TP moulded case circuit breaker (DIN type) breaking capacity 36K complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 160A, 415V

EI0485

Installation, testing and commissioning of SPN DB (DIN type, horizontal/vertical) with no door, metal door or arcylic door (double/single door) complete with all accessories to accommodate incomingRCCB DP 16/25A sensitivity 30/100/300mA and outgoing SP MCB 6/10/16A on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 4 way

EI0495

Installation, testing and commissioning of SPN DB (DIN type, horizontal/vertical) with no door, metal door or arcylic door (double/single door) complete with all accessories to accommodate incomingRCCB DP 32/40A sensitivity 30/100/300mA and outgoing SP MCB 6/10/16A on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 8 way

EI0505

Page 227: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 228

Department of Engineering Services, MoWHS

MT4675 Ferrule type brass thimble - 6A 2.66 each MT4676 Ferrule type brass thimble - 10A 2.66 each MT4677 Ferrule type brass thimble - 16A 2.66 each MT4680 Ferrule type brass thimble - 32A 1 each MT4681 Ferrule type brass thimble - 40A 1 each

Coefficient for per each of EI0515

Code Description Quant Units LB0056 Wireman Gd.1 0.2428 day LB0069 Wireman Gd.2 0.2428 day MT4675 Ferrule type brass thimble - 6A 4 each MT4676 Ferrule type brass thimble - 10A 4 each MT4677 Ferrule type brass thimble - 16A 4 each MT4683 Ferrule type brass thimble - 63A 2 each

Coefficient for per each of EI0525

Code Description Quant Units LB0056 Wireman Gd.1 0.225 day LB0069 Wireman Gd.2 0.225 day MT4675 Ferrule type brass thimble - 6A 4 each MT4676 Ferrule type brass thimble - 10A 4 each MT4677 Ferrule type brass thimble - 16A 4 each MT4680 Ferrule type brass thimble - 32A 4 each

Coefficient for per each of EI0535

Code Description Quant Units LB0056 Wireman Gd.1 0.202 day LB0069 Wireman Gd.2 0.202 day MT4675 Ferrule type brass thimble - 6A 6 each MT4676 Ferrule type brass thimble - 10A 6 each MT4677 Ferrule type brass thimble - 16A 6 each MT4683 Ferrule type brass thimble - 63A 4 each

Coefficient for per each of EI0545

Code Description Quant Units LB0056 Wireman Gd.1 0.268 day LB0069 Wireman Gd.2 0.268 day MT4675 Ferrule type brass thimble - 6A 8 each MT4676 Ferrule type brass thimble - 10A 8 each MT4677 Ferrule type brass thimble - 16A 8 each MT4680 Ferrule type brass thimble - 32A 2 each MT4684 Ferrule type brass thimble - 100A 2 each

Installation, testing and commissioning of SPN DB (DIN type, horizontal/vertical) with no door, metal door or arcylic door (double/single door) complete with all accessories to accommodate incomingRCCB DP 63A sensitivity 30/100/300mA and outgoing SP MCB 6/10/16A on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 12 way

EI0515

Installation, testing and commissioning of TPN DB (DIN type, horizontal/vertical) with no door, metal door or arcylic door (double/single door) complete with all accessories to accommodate incomingRCCB FP 16/25/32A sensitivity 30/100/300mA and outgoing SP MCB 6/10/16A on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 4 way

Installation, testing and commissioning of TPN DB (DIN type, horizontal/vertical) with no door, metal door or arcylic door (double/single door) complete with all accessories to accommodate incomingRCCB FP 40/63A sensitivity 30/100/300mA and outgoing SP MCB 6/10/16A on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 6 way

EI0525

EI0535

Installation, testing and commissioning of TPN DB (DIN type, horizontal/vertical) with no door, metal door or arcylic door (double/single door) complete with all accessories to accommodate incomingRCCB/ELCB/RCBO FP 100A sensitivity 30/100/300mA and outgoing SP MCB 6/10/16A on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 8 way

EI0545

Page 228: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 229

Department of Engineering Services, MoWHS

Coefficient for per each of EI0555

Code Description Quant Units LB0056 Wireman Gd.1 0.417 day LB0069 Wireman Gd.2 0.417 day MT4675 Ferrule type brass thimble - 6A 12 each MT4676 Ferrule type brass thimble - 10A 12 each MT4677 Ferrule type brass thimble - 16A 12 each MT4684 Ferrule type brass thimble - 100A 2 each MT4685 Ferrule type brass thimble - 125A 2 each

Coefficient for per each of EI0565

Code Description Quant Units LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4677 Ferrule type brass thimble - 16A 2 each MT4680 Ferrule type brass thimble - 32A 2 each

Coefficient for per each of EI0575

Code Description Quant Units LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4676 Ferrule type brass thimble - 10A 2 each MT4678 Ferrule type brass thimble - 20A 2 each

Coefficient for per each of EI0576

Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4678 Ferrule type brass thimble - 20A 4 each

Coefficient for per each of EI0577

Code Description Quant Units LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4680 Ferrule type brass thimble - 32A 4 each

Installation, testing and commissioning of DP trimer switch assembly in a case complete with all accessories to accommodate on/in prefabricated MS surface /MS cubical control panel board recessed including drilling holes, connections etc. as required - Adjustment range either 24/24hrs or 7days/24hrs

EI0565

Installation, testing and commissioning of metal clad commercial/industrial type plug& socket complete with all accessories to accommodate on/in surface or recessed including drilling holes, connections etc. as required - DP, 10/20A with earth terminal and incoming control gear DP MCB 10/20A

EI0575

Installation, testing and commissioning of metal clad commercial/industrial type plug& socket complete with all accessories to accommodate on/in surface or recessed including drilling holes, connections etc. as required - 4 pole 20A with earth terminal and incoming control gear 4 pole MCB 20A

EI0576

Installation, testing and commissioning of metal clad commercial/industrial type plug& socket complete with all accessories to accommodate on/in surface or recessed including drilling holes, connections etc. as required - 4 pole 32A with earth terminal and incoming control gear 4 pole MCB 32A

EI0577

Installation, testing and commissioning of TPN DB (DIN type, horizontal/vertical) with no door, metal door or arcylic door (double/single door) complete with all accessories to accommodate incomingRCCB/ELCB/RCBO FP 125A sensitivity 30/100/300mA and outgoing SP MCB 6/10/16A on/in prefabricated MS surface /MS cubical control panel board including drilling holes, connections etc. as required - 12 way

EI0555

Page 229: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 230

Department of Engineering Services, MoWHS

Coefficient for per each of EI0578

Code Description Quant Units LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 0.75 day MT4683 Ferrule type brass thimble - 63A 4 each

Coefficient for per sq.m of EI0590

Code Description Quant Units LB0032 Blacksmith (metal-worker) 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT6635 Rolled Steel Section 250MPa - Angles 18 kg MT6637 Rolled Steel Section 250MPa - Flats 6.6 kg

Coefficient for per cu.m of EI0600

Code Description Quant Units LB0032 Blacksmith (metal-worker) 0.5 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.75 day MT6635 Rolled Steel Section 250MPa - Angles 80 kg MT6637 Rolled Steel Section 250MPa - Flats 15.83 kg MT6650 Sheet (250 MPa) - 1mm 59.45 kg

Coefficient for per each of EI0610

Code Description Quant Units LB0056 Wireman Gd.1 0.08 day LB0069 Wireman Gd.2 0.08 day MT6651 Sheet (250 MPa) - 2mm 0.432 kg

CHAPTER 16: EARTHING

Coefficient for per each of ET0001

Code Description Quant Units LB0036 Mason Gd.1 0.11417 day LB0051 Mason Gd.2 0.04654 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day LB0077 Labourer 0.53343 day MT6510 Plate - GI Plate, 600x600x6mm 1 each MT6555 Accessories - Charcoal 96 kg MT6556 Accessories - Salt 5 kg

Installation, testing and commissioning of metal clad commercial/industrial type plug& socket complete with all accessories to accommodate on/in surface or recessed including drilling holes, connections etc. as required - 4 pole 63A with earth terminal and incoming control gear 4 pole MCB 63A

EI0578

Providing and fixing of prefabricated panel board with minimum 50x50x6mm angle iron frame work with horizontal and vertical intermidiate members of flat iron 40x6mm for mounting of switch gears incoming/ outgoing bus bar chambers including drilling holes, painting, grouting etc. as required - mounted fixed type metal board of welded construction

EI0590

Providing and fixing of prefabricated panel board with minimum 50x50x6mm angle iron frame work with horizontal and vertical intermidiate members of flat iron 40x6mm and 24 SWG sheet cover for mountingof switch gears incoming/ outgoing bus bars including drilling holes, insulator, painting, denting, grouting etc. as required - Floor mounted cubical control panel board of welded construction

EI0600

Providing and fixing medium volt danger notice plate made of mild steel and painted with vitreous enamelled white paint on both sides, and with inscription in signal red colour on front side as required on prefabricated MS surface/ MS cubical control panel board on surface including drilling holes etc. as required - 200x150x2mm

EI0610

Providing and fixing of earthing including all accessories, machinery enclosure, C.I cover plate having locking arrangement, watering pipe with excavation and refilling work including charcoal or coke and salt complete as required as per standard earthing drawing - With G.I earth plate 600x600x6mm

ET0001

Page 230: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 231

Department of Engineering Services, MoWHS

MT6604 Sand 0.04694 cu.m MT6666 G.I Pipe heavy duty - 20mm 2.7 m MT6680 Bricks 2nd class 0.05588 1000# MT6681 Grey Cement 0.01543 tonne MT6684 C.I. Manhole Cover with frame, 300 x 300mm inside size 1 each

Coefficient for per each of ET0002

Code Description Quant Units LB0036 Mason Gd.1 0.11417 day LB0051 Mason Gd.2 0.04654 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day LB0077 Labourer 0.53343 day MT6511 Plate - Copper Plate, 600x600x3mm 1 each MT6555 Accessories - Charcoal 96 kg MT6556 Accessories - Salt 5 kg MT6604 Sand 0.04694 cu.m MT6666 G.I Pipe heavy duty - 20mm 2.7 m MT6680 Bricks 2nd class 0.05588 1000# MT6681 Grey Cement 0.01543 tonne MT6684 C.I. Manhole Cover with frame, 300 x 300mm inside size 1 each

ET0015

Coefficient for per m of ET0015

Code Description Quant Units LB0056 Wireman Gd.1 0.01667 day LB0069 Wireman Gd.2 0.01667 day LB0077 Labourer 0.15876 day MT6530 Wire - GI, 4mm dia (8swg) 1 m MT6665 G.I Pipe heavy duty - 15mm 1 m

ET0016

Coefficient for per m of ET0016

Code Description Quant Units LB0056 Wireman Gd.1 0.01667 day LB0069 Wireman Gd.2 0.01667 day LB0077 Labourer 0.15876 day MT6536 Wire - Copper, 4mm dia (8swg) 1 m MT6665 G.I Pipe heavy duty - 15mm 1 m

ET0030

Coefficient for per m of ET0030

Code Description Quant Units LB0051 Mason Gd.2 0.0325 day LB0056 Wireman Gd.1 0.015 day LB0069 Wireman Gd.2 0.0475 day MT6530 Wire - GI, 4mm dia (8swg) 1 m

ET0031

Coefficient for per m of ET0031

Code Description Quant Units LB0051 Mason Gd.2 0.0325 day

Providing and fixing of earthing including all accessories, machinery enclosure, C.I cover plate having locking arrangement, watering pipe with excavation and refilling work including charcoal or coke and salt complete as required as per standard earthing drawing - With copper earth plate 600x600x3mm

ET0002

Providing and laying earth connection from earth electrodes in 15mm dia G.I pipe from earth electrodes as required as per guidence of standard earthing drawing - With 4.06mm dia (8SWG) G.I wire

Providing and laying earth connection from earth electrodes in 15mm dia G.I pipe from earth electrodes as required as per guidence of standard earthing drawing - With 4.06mm dia (8SWG) copper wire

Providing and fixing of wire on surface or in recessed for loop earthing as required - With 4.06mm dia (8SWG) G.I wire

Providing and fixing of wire on surface or in recessed for loop earthing as required - With 4.06mm dia (8SWG) copper wire

Page 231: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 232

Department of Engineering Services, MoWHS

LB0056 Wireman Gd.1 0.015 day LB0069 Wireman Gd.2 0.0475 day MT6536 Wire - Copper, 4mm dia (8swg) 1 m

ET0045

Coefficient for per m of ET0045

Code Description Quant Units LB0056 Wireman Gd.1 0.00417 day LB0069 Wireman Gd.2 0.00417 day LB0077 Labourer 0.05292 day MT6530 Wire - GI, 4mm dia (8swg) 1 m

ET0046

Coefficient for per m of ET0046

Code Description Quant Units LB0056 Wireman Gd.1 0.00417 day LB0069 Wireman Gd.2 0.00417 day LB0075 Labourer 0.5292 day MT6536 Wire - Copper, 4mm dia (8swg) 1 m

ET0060

Coefficient for per m of ET0060

Code Description Quant Units LB0056 Wireman Gd.1 0.0044 day LB0069 Wireman Gd.2 0.0044 day LB0077 Labourer 0.05292 day MT6533 Wire - G.I, 4.88mm dia (6SWG) 1 m

ET0061

Coefficient for per m of ET0061

Code Description Quant Units LB0056 Wireman Gd.1 0.0044 day LB0069 Wireman Gd.2 0.0044 day LB0077 Labourer 0.05292 day MT6538 Wire - Copper, 4.88mm dia (6SWG) 1 m

ET0075

Coefficient for per m of ET0075

Code Description Quant Units LB0056 Wireman Gd.1 0.0055 day LB0069 Wireman Gd.2 0.0055 day LB0077 Labourer 0.05292 day MT6517 Strip - GI Tape\Strip 25x4 mm 1 m

ET0076

Coefficient for per m of ET0076

Code Description Quant Units LB0056 Wireman Gd.1 0.0055 day LB0069 Wireman Gd.2 0.0055 day LB0077 Labourer 0.05292 day MT6519 Strip - Copper Tape\Strip 25x4 1 m

Providing and laying of wire at 0.5m below ground level for conductor earth electrodes including soldering etc. as required - With 4.06mm dia (8SWG) G.I wire

Providing and laying of wire at 0.5m below ground level for conductor earth electrodes including soldering etc. as required - With 4.06mm dia (8SWG) copper wire

Providing and laying of wire at 0.5m below ground level for conductor earth electrodes including soldering etc. as required - With 4.88mm dia (6SWG) G.I wire

Providing and laying of wire at 0.5m below ground level for conductor earth electrodes including soldering etc. as required - With 4.88mm dia (6SWG) copper wire

Providing and laying of metal strip at 0.5m below ground level for as strip earth electrodes including soldering etc. as required - 25x4mm G.I strip

Providing and laying of metal strip at 0.5m below ground level for as strip earth electrodes including soldering etc. as required - 25x4mm copper strip

Page 232: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 233

Department of Engineering Services, MoWHS

ET0077

Coefficient for per m of ET0077

Code Description Quant Units LB0056 Wireman Gd.1 0.0067 day LB0069 Wireman Gd.2 0.0067 day LB0077 Labourer 0.05292 day MT6518 Strip - GI Tape\Strip 25x6 mm 1 m

ET0090

Coefficient for per m of ET0090

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day LB0077 Labourer 0.05292 day MT6517 Strip - GI Tape\Strip 25x4 mm 1 m MT6669 G.I Pipe heavy duty - 40mm 1 m

ET0091

Coefficient for per m of ET0091

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day LB0077 Labourer 0.05292 day MT6519 Strip - Copper Tape\Strip 25x4 1 m MT6669 G.I Pipe heavy duty - 40mm 1 m

ET0105

Coefficient for per m of ET0105

Code Description Quant Units LB0051 Mason Gd.2 0.025 day LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.075 day MT6517 Strip - GI Tape\Strip 25x4 mm 1 m

ET0106

Coefficient for per m of ET0106

Code Description Quant Units LB0051 Mason Gd.2 0.025 day LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.075 day MT6519 Strip - Copper Tape\Strip 25x4 1 m

ET0120

Coefficient for per m of ET0120

Code Description Quant UnitsLB0056 Wireman Gd.1 0.0044 dayLB0069 Wireman Gd.2 0.0044 dayLB0077 Labourer 0.05292 day

MT6534 Wire - 2.032 mm dia.(14SWG) bare G.I 1 m

Providing and laying of metal strip on surface or in recessed for earth connections/loop earthing as required - 25x4mm G.I strip

Providing and laying of metal strip on surface or in recessed for earth connections/loop earthing as required - 25x4mm copper strip

Providing and laying of metal strip in 40mm dia G.I pipe at 0.5m below ground level from earth electrodes including soldering etc. as required - 25x4mm G.I strip

Providing and laying of metal strip at 0.5m below ground level for as strip earth electrodes including soldering etc. as required - 25x6mm G.I strip

Providing and laying of metal strip in 40mm dia G.I pipe at 0.5m below ground level from earth electrodes including soldering etc. as required - 25x4mm copper strip

Providing and drawing wire for loop earthing in existing surface/ recessed PVC/MS/ steel conduit or casing capping or wooden batten along with other wires as required - 2.032mm (14SWG) G.I wire

Page 233: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 234

Department of Engineering Services, MoWHS

ET0121

Coefficient for per m of ET0121

Code Description Quant UnitsLB0056 Wireman Gd.1 0.0044 dayLB0069 Wireman Gd.2 0.0044 dayLB0077 Labourer 0.05292 day

MT6539 Wire - 2.032 mm dia.(14SWG) bare copper wire 1 m

CHAPTER 17: LIGHTNING PROTECTION

LG0001

Coefficient for per each of LG0001

Code Description Quant Units LB0051 Mason Gd.2 0.167 day LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.333 day MT5630 Copper tube finial with base plate 85x3mm - 25mm dia, 300mm long with sing 1 each

LG0002

Coefficient for per each of LG0002

Code Description Quant Units LB0051 Mason Gd.2 0.2 day LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.5 day MT5631 Copper tube finial with base plate 85x3mm - 25mm dia, 900mm long with fou 1 each

LG0003

Coefficient for per each of LG0003

Code Description Quant Units LB0051 Mason Gd.2 0.167 day LB0056 Wireman Gd.1 0.1 day LB0069 Wireman Gd.2 0.333 day MT5630 G.I tube finial with copper base plate 85x6mm - 25mm dia, 300mm long with s 1 each LG0015 Coefficient for per each of LG0015

Code Description Quant Units LB0054 Plumber Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day LG0016 Coefficient for per each of LG0016

Code Description Quant Units LB0054 Plumber Gd.2 0.125 day LB0069 Wireman Gd.2 0.125 day

LG0030

Coefficient for per each of LG0030

Code Description Quant Units LB0051 Mason Gd.2 0.0125 day

Rivetting, sweating and soldering as required - Copper tape with another copper tape

Rivetting, sweating and soldering as required - G.I tape with another G.I tape

Providing and fixing metal strip on parapet or surface of wall/roof for lightning conductor as required for horizontal run - 25x4mm G.I strip

Providing and drawing wire for loop earthing in existing surface/ recessed PVC/MS/ steel conduit or casing capping or wooden batten along with other wires as required - 2.032mm (14SWG) copper wire

Providing and fixing lightning conductor including holes etc. complete as required - 25mm dia 300mm long copper tube single prong at top with 85mm dia 3mm thick copper base plate

Providing and fixing lightning conductor including holes etc. complete as required - 25mm dia 900mm long copper tube four prong at top with 85mm dia 3mm thick copper base plate

Providing and fixing lightning conductor including holes etc. complete as required - 25mm dia 300mm long G.I tube single prong at top with 85mm dia 6mm thick copper base plate

Page 234: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 235

Department of Engineering Services, MoWHS

LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.0375 day MT6517 Strip - GI Tape\Strip 25x4 mm 1 m

LG0031

Coefficient for per each of LG0031

Code Description Quant Units LB0051 Mason Gd.2 0.0125 day LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.0375 day MT6519 Strip - Copper Tape\Strip 25x4 1 m

LG0045

Coefficient for per each of LG0045

Code Description Quant Units LB0051 Mason Gd.2 0.025 day LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.075 day MT6517 Strip - GI Tape\Strip 25x4 mm 1 m

LG0046

Coefficient for per each of LG0046

Code Description Quant Units LB0051 Mason Gd.2 0.025 day LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.075 day MT6519 Strip - Copper Tape\Strip 25x4 1 m

CHAPTER 18: POWER CABLE (Supply)

PC0001

Coefficient for per m of PC0001

Code Description Quant Units

MT4210Power Cables (1.1kV) Single Core Aluminium-Unarmoured, PVC insulated & sheathed - 150 sq.mm 1 m

PC0002

Coefficient for per m of PC0002

Code Description Quant Units

MT4211Power Cables (1.1kV) Single Core Aluminium-Unarmoured, PVC insulated & sheathed - 185 sq.mm 1 m

PC0003

Coefficient for per m of PC0003

Code Description Quant Units

MT4212Power Cables (1.1kV) Single Core Aluminium-Unarmoured, PVC insulated & sheathed - 240 sq.mm 1 m

PC0004

Coefficient for per m of PC0004

Code Description Quant Units

MT4213Power Cables (1.1kV) Single Core Aluminium-Unarmoured, PVC insulated & sheathed - 300 sq.mm 1 m

Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 240 sq.mm

Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 300 sq.mm

Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 150 sq.mm

Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 185 sq.mm

Providing and fixing metal strip on parapet or surface of wall/roof for lightning conductor as required for horizontal run - 25x4mm copper strip

Providing and fixing metal strip on parapet or surface of wall/roof for lightning conductor as required for vertical run - 25x4mm G.I strip

Providing and fixing metal strip on parapet or surface of wall/roof for lightning conductor as required for vertical run - 25x4mm copper strip

Page 235: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 236

Department of Engineering Services, MoWHS

PC0005

Coefficient for per m of PC0005

Code Description Quant Units

MT4214Power Cables (1.1kV) Single Core Aluminium-Unarmoured, PVC insulated & sheathed - 400 sq.mm 1 m

PC0006

Coefficient for per m of PC0006

Code Description Quant Units

MT4215Power Cables (1.1kV) Single Core Aluminium-Unarmoured, PVC insulated & sheathed - 500 sq.mm 1 m

PC0020

Coefficient for per m of PC0020

Code Description Quant Units

MT4230Power Cables (1.1kV) 2- Core Aluminium-Unarmoured, PVC insulated & sheathed - 2.5 sq.mm 1 m

PC0021

Coefficient for per m of PC0021

Code Description Quant Units

MT4231Power Cables (1.1kV) 2- Core Aluminium-Unarmoured, PVC insulated & sheathed - 4 sq.mm 1 m

PC0022

Coefficient for per m of PC0022

Code Description Quant Units

MT4232Power Cables (1.1kV) 2- Core Aluminium-Unarmoured, PVC insulated & sheathed - 6 sq.mm 1 m

PC0023

Coefficient for per m of PC0023

Code Description Quant Units

MT4233Power Cables (1.1kV) 2- Core Aluminium-Unarmoured, PVC insulated & sheathed - 10 sq.mm 1 m

PC0024

Coefficient for per m of PC0024

Code Description Quant Units

MT4234Power Cables (1.1kV) 2- Core Aluminium-Unarmoured, PVC insulated & sheathed - 16 sq.mm 1 m

PC0035

Coefficient for per m of PC0035

Code Description Quant Units

MT4245Power Cables (1.1kV) 3- Core Aluminium-Unarmoured, PVC insulated & sheathed - 2.5 sq.mm 1 m

PC0036

Coefficient for per m of PC0036

Code Description Quant Units

MT4246Power Cables (1.1kV) 3- Core Aluminium-Unarmoured, PVC insulated & sheathed - 4 sq.mm 1 m

PC0037

Coefficient for per m of PC0037

Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 400 sq.mm

Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 500 sq.mm

Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 16 sq.mm

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured cables - 2.5 sq.mm

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 4 sq.mm

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 6 sq.mm

Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 2.5 sq.mm

Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 4 sq.mm

Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 6 sq.mm

Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 10 sq.mm

Page 236: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 237

Department of Engineering Services, MoWHS

Code Description Quant Units

MT4247Power Cables (1.1kV) 3- Core Aluminium-Unarmoured, PVC insulated & sheathed - 6 sq.mm 1 m

PC0038

Coefficient for per m of PC0038

Code Description Quant Units

MT4248Power Cables (1.1kV) 3- Core Aluminium-Unarmoured, PVC insulated & sheathed - 10 sq.mm 1 m

PC0039

Coefficient for per m of PC0039

Code Description Quant Units

MT4249Power Cables (1.1kV) 3- Core Aluminium-Unarmoured, PVC insulated & sheathed - 16 sq.mm 1 m

PC0040

Coefficient for per m of PC0040

Code Description Quant Units

MT4250Power Cables (1.1kV) 3- Core Aluminium-Unarmoured, PVC insulated & sheathed - 25 sq.mm 1 m

PC0050

Coefficient for per m of PC0050

Code Description Quant Units

MT4260Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 25 sq.mm 1 m

PC0051

Coefficient for per m of PC0051

Code Description Quant Units

MT4261Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 35 sq.mm 1 m

PC0052

Coefficient for per m of PC0052

Code Description Quant Units

MT4262Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 50 sq.mm 1 m

PC0053

Coefficient for per m of PC0053

Code Description Quant Units

MT4263Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 70 sq.mm 1 m

PC0054

Coefficient for per m of PC0054

Code Description Quant Units

MT4264Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 95 sq.mm 1 m

PC0055

Coefficient for per m of PC0055

Code Description Quant Units

MT4265Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 120 sq.mm 1 m

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 35 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 50 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 70 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 95 sq.mm

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 10 sq.mm

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 16 sq.mm

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 25 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 25 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 120 sq.mm

Page 237: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 238

Department of Engineering Services, MoWHS

PC0056

Coefficient for per m of PC0056

Code Description Quant Units

MT4266Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 150 sq.mm 1 m

PC0057

Coefficient for per m of PC0057

Code Description Quant Units

MT4268Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 225 sq.mm 1 m

PC0058

Coefficient for per m of PC0058

Code Description Quant Units

MT4269Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 240 sq.mm 1 m

PC0059

Coefficient for per m of PC0059

Code Description Quant Units

MT4270Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 300 sq.mm 1 m

PC0060

Coefficient for per m of PC0060

Code Description Quant Units

MT4271Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 400 sq.mm 1 m

PC0061

Coefficient for per m of PC0061

Code Description Quant Units

MT4272Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 500 sq.mm 1 m

PC0062

Coefficient for per m of PC0062

Code Description Quant Units

MT4273Power Cables (1.1kV) 3.5-Core Aluminium - Unarmoured, HD, PVC insulated & sheathed - 630 sq.mm 1 m

PC0075

Coefficient for per m of PC0075

Code Description Quant Units

MT4285Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 2.5 sq.mm 1 m

PC0076

Coefficient for per m of PC0076

Code Description Quant Units

MT4286Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 4 sq.mm 1 m

PC0077

Coefficient for per m of PC0077

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 300 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 400 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 500 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 630 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 150 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 225 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 240 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 2.5 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 4 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 6 sq.mm

Page 238: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 239

Department of Engineering Services, MoWHS

Code Description Quant Units

MT4287Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 6 sq.mm 1 m

PC0078

Coefficient for per m of PC0078

Code Description Quant Units

MT4288Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 10 sq.mm 1 m

PC0079

Coefficient for per m of PC0079

Code Description Quant Units

MT4289Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 16 sq.mm 1 m

PC0080

Coefficient for per m of PC0080

Code Description Quant Units

MT4290Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 25 sq.mm 1 m

PC0081

Coefficient for per m of PC0081

Code Description Quant Units

MT4291Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 35 sq.mm 1 m

PC0082

Coefficient for per m of PC0082

Code Description Quant Units

MT4292Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 50 sq.mm 1 m

PC0083

Coefficient for per m of PC0083

Code Description Quant Units

MT4293Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 70 sq.mm 1 m

PC0084

Coefficient for per m of PC0084

Code Description Quant Units

MT4294Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 95 sq.mm 1 m

PC0085

Coefficient for per m of PC0085

Code Description Quant Units

MT4295Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 120 sq.mm 1 m

PC0086

Coefficient for per m of PC0086

Code Description Quant Units

MT4296Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 150 sq.mm 1 m

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 10 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 16 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 25 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 35 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 50 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 70 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 95 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 120 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 150 sq.mm

Page 239: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 240

Department of Engineering Services, MoWHS

PC0087

Coefficient for per m of PC0087

Code Description Quant Units

MT4297Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 225 sq.mm 1 m

PC0088

Coefficient for per m of PC0088

Code Description Quant Units

MT4298Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 240 sq.mm 1 m

PC0089

Coefficient for per m of PC0089

Code Description Quant Units

MT4299Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 300 sq.mm 1 m

PC0090

Coefficient for per m of PC0090

Code Description Quant Units

MT4300Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 400 sq.mm 1 m

PC0091

Coefficient for per m of PC0091

Code Description Quant Units

MT4301Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 500 sq.mm 1 m

PC0092

Coefficient for per m of PC0092

Code Description Quant Units

MT4302Power Cables (1.1kV) 4-Core Aluminium - Unarmoured, PVC insulated & sheathed - 630 sq.mm 1 m

PC0105

Coefficient for per m of PC0105

Code Description Quant Units

MT4110Power Cables (1.1kV) Single Core Aluminium-Armoured, PVC insulated & sheathed - 150 sq.mm 1 m

PC0106

Coefficient for per m of PC0106

Code Description Quant Units

MT4111Power Cables (1.1kV) Single Core Aluminium-Armoured, PVC insulated & sheathed - 185 sq.mm 1 m

PC0107

Coefficient for per m of PC0107

Code Description Quant Units

MT4112Power Cables (1.1kV) Single Core Aluminium-Armoured, PVC insulated & sheathed - 240 sq.mm 1 m

PC0108

Coefficient for per m of PC0108

Code Description Quant Units

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 240 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 300 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 400 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 500 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 225 sq.mm

Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 300 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor un-armoured power cables - 630 sq.mm

Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 150 sq.mm

Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 185 sq.mm

Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 240 sq.mm

Page 240: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 241

Department of Engineering Services, MoWHS

MT4113Power Cables (1.1kV) Single Core Aluminium-Armoured, PVC insulated & sheathed - 300 sq.mm 1 m

PC0109

Coefficient for per m of PC0109

Code Description Quant Units

MT4114Power Cables (1.1kV) Single Core Aluminium-Armoured, PVC insulated & sheathed - 400 sq.mm 1 m

PC0110

Coefficient for per m of PC0110

Code Description Quant Units

MT4115Power Cables (1.1kV) Single Core Aluminium-Armoured, PVC insulated & sheathed - 500 sq.mm 1 m

PC0120

Coefficient for per m of PC0120

Code Description Quant Units

MT4125Power Cables (1.1kV) 2- Core Aluminium-Armoured, PVC insulated & sheathed - 2.5 sq.mm 1 m

PC0121

Coefficient for per m of PC0121

Code Description Quant Units

MT4126Power Cables (1.1kV) 2- Core Aluminium-Armoured, PVC insulated & sheathed - 4 sq.mm 1 m

PC0122

Coefficient for per m of PC0122

Code Description Quant Units

MT4127Power Cables (1.1kV) 2- Core Aluminium-Armoured, PVC insulated & sheathed - 6 sq.mm 1 m

PC0123

Coefficient for per m of PC0123

Code Description Quant Units

MT4128Power Cables (1.1kV) 2- Core Aluminium-Armoured, PVC insulated & sheathed - 10 sq.mm 1 m

PC0124

Coefficient for per m of PC0124

Code Description Quant Units

MT4129Power Cables (1.1kV) 2- Core Aluminium-Armoured, PVC insulated & sheathed - 16 sq.mm 1 m

PC0135

Coefficient for per m of PC0135

Code Description Quant Units

MT4140Power Cables (1.1kV) 3- Core Aluminium-Armoured, PVC insulated & sheathed - 2.5 sq.mm 1 m

PC0136

Coefficient for per m of PC0136

Code Description Quant Units

MT4141Power Cables (1.1kV) 3- Core Aluminium-Armoured, PVC insulated & sheathed - 4 sq.mm 1 m

PC0137

Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 400 sq.mm

Supplying of Single Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 500 sq.mm

Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 2.5 sq.mm

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 2.5 sq.mm

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 4 sq.mm

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 6 sq.mm

Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 4 sq.mm

Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 6 sq.mm

Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 10 sq.mm

Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 16 sq.mm

Page 241: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 242

Department of Engineering Services, MoWHS

Coefficient for per m of PC0137

Code Description Quant Units

MT4142Power Cables (1.1kV) 3- Core Aluminium-Armoured, PVC insulated & sheathed - 6 sq.mm 1 m

PC0138

Coefficient for per m of PC0138

Code Description Quant Units

MT4143Power Cables (1.1kV) 3- Core Aluminium-Armoured, PVC insulated & sheathed - 10 sq.mm 1 m

PC0139

Coefficient for per m of PC0139

Code Description Quant Units

MT4144Power Cables (1.1kV) 3- Core Aluminium-Armoured, PVC insulated & sheathed - 16 sq.mm 1 m

PC0140

Coefficient for per m of PC0140

Code Description Quant Units

MT4145Power Cables (1.1kV) 3- Core Aluminium-Armoured, PVC insulated & sheathed - 25 sq.mm 1 m

PC0150

Coefficient for per m of PC0150

Code Description Quant Units

MT4155Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 25 sq.mm 1 m

PC0151

Coefficient for per m of PC0151

Code Description Quant Units

MT4156Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 35 sq.mm 1 m

PC0152

Coefficient for per m of PC0152

Code Description Quant Units

MT4157Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 50 sq.mm 1 m

PC0153

Coefficient for per m of PC0153

Code Description Quant Units

MT4158Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 70 sq.mm 1 m

PC0154

Coefficient for per m of PC0154

Code Description Quant Units

MT4159Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 95 sq.mm 1 m

PC0155

Coefficient for per m of PC0155

Code Description Quant Units

MT4160Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 120 sq.mm 1 m

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 10 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 50 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 70 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 95 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 120 sq.mm

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 16 sq.mm

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 25 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 25 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 35 sq.mm

Page 242: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 243

Department of Engineering Services, MoWHS

PC0156

Coefficient for per m of PC0156

Code Description Quant Units

MT4161Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 150 sq.mm 1 m

PC0157

Coefficient for per m of PC0157

Code Description Quant Units

MT4163Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 225 sq.mm 1 m

PC0158

Coefficient for per m of PC0158

Code Description Quant Units

MT4164Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 240 sq.mm 1 m

PC0159

Coefficient for per m of PC0159

Code Description Quant Units

MT4165Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 300 sq.mm 1 m

PC0160

Coefficient for per m of PC0160

Code Description Quant Units

MT4166Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 400 sq.mm 1 m

PC0161

Coefficient for per m of PC0161

Code Description Quant Units

MT4167Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 500 sq.mm 1 m

PC0162

Coefficient for per m of PC0162

Code Description Quant Units

MT4168Power Cables (1.1kV) 3.5-Core Aluminium - Armoured, PVC insulated & sheathed - 630 sq.mm 1 m

PC0175

Coefficient for per m of PC0175

Code Description Quant Units

MT4180Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 2.5 sq.mm 1 m

PC0176

Coefficient for per m of PC0176

Code Description Quant Units

MT4181Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 4 sq.mm 1 m

PC0177

Coefficient for per m of PC0177

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 6 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 4 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 400 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 500 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 630 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 2.5 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 150 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 225 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 240 sq.mm

Supplying of 3.5- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 300 sq.mm

Page 243: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 244

Department of Engineering Services, MoWHS

Code Description Quant Units

MT4182Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 6 sq.mm 1 m

PC0178

Coefficient for per m of PC0178

Code Description Quant Units

MT4183Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 10 sq.mm 1 m

PC0179

Coefficient for per m of PC0179

Code Description Quant Units

MT4184Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 16 sq.mm 1 m

PC0180

Coefficient for per m of PC0180

Code Description Quant Units

MT4185Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 25 sq.mm 1 m

PC0181

Coefficient for per m of PC0181

Code Description Quant Units

MT4186Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 35 sq.mm 1 m

PC0182

Coefficient for per m of PC0182

Code Description Quant Units

MT4187Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 50 sq.mm 1 m

PC0183

Coefficient for per m of PC0183

Code Description Quant Units

MT4188Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 70 sq.mm 1 m

PC0184

Coefficient for per m of PC0184

Code Description Quant Units

MT4189Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 95 sq.mm 1 m

PC0185

Coefficient for per m of PC0185

Code Description Quant Units

MT4190Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 120 sq.mm 1 m

PC0186

Coefficient for per m of PC0186

Code Description Quant Units

MT4191Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 150 sq.mm 1 m

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 10 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 70 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 95 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power 120 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 150 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 16 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 25 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 35 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 50 sq.mm

Page 244: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 245

Department of Engineering Services, MoWHS

PC0187

Coefficient for per m of PC0187

Code Description Quant Units

MT4192Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 225 sq.mm 1 m

PC0188

Coefficient for per m of PC0188

Code Description Quant Units

MT4193Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 240 sq.mm 1 m

PC0189

Coefficient for per m of PC0189

Code Description Quant Units

MT4194Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 300 sq.mm 1 m

PC0190

Coefficient for per m of PC0190

Code Description Quant Units

MT4195Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 400 sq.mm 1 m

PC0191

Coefficient for per m of PC0191

Code Description Quant Units

MT4196Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 500 sq.mm 1 m

PC0192

Coefficient for per m of PC0192

Code Description Quant Units

MT4197Power Cables (1.1kV) 4-Core Aluminium - Armoured, PVC insulated & sheathed - 630 sq.mm 1 m

PC0205

Coefficient for per m of PC0205

Code Description Quant Units

MT4315Power Cables (1.1kV) 2- Core Copper- Armoured, PVC insulated & sheathed - 2.5 sq.mm 1 m

PC0206

Coefficient for per m of PC0206

Code Description Quant Units

MT4316Power Cables (1.1kV) 2- Core Copper-Armoured, PVC insulated & sheathed - 4 sq.mm 1 m

PC0207

Coefficient for per m of PC0207

Code Description Quant Units

MT4317Power Cables (1.1kV) 2- Core Copper-Armoured, PVC insulated & sheathed - 6 sq.mm 1 m

PC0208

Coefficient for per m of PC0208

Code Description Quant Units

Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 6 sq.mm

Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 10 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 600 sq.mm

Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 2.5 sq.mm

Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 4 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 225 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 240 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 300 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 400 sq.mm

Supplying of 4- Core 1.1KV grade PVC insulated and sheathed Aluminium conductor armoured power cables - 500 sq.mm

Page 245: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 246

Department of Engineering Services, MoWHS

MT4318Power Cables (1.1kV) 2- Core Copper-Armoured, PVC insulated & sheathed - 10 sq.mm 1 m

PC0209

Coefficient for per m of PC0209

Code Description Quant Units

MT4319Power Cables (1.1kV) 2 - Core Copper-Armoured, PVC insulated & sheathed - 16 sq.mm 1 m

PC0220

Coefficient for per m of PC0220

Code Description Quant Units

MT4330Power Cables (1.1kV) 3- Core Copper-Armoured, PVC insulated & sheathed - 2.5 sq.mm 1 m

PC0221

Coefficient for per m of PC0221

Code Description Quant Units

MT4331Power Cables (1.1kV) 3- Core Copper-Armoured, PVC insulated & sheathed - 4 sq.mm 1 m

PC0222

Coefficient for per m of PC0222

Code Description Quant Units

MT4332Power Cables (1.1kV) 3- Core Copper-Armoured, PVC insulated & sheathed - 6 sq.mm 1 m

PC0223

Coefficient for per m of PC0223

Code Description Quant Units

MT4333Power Cables (1.1kV) 3- Core Copper-Armoured, PVC insulated & sheathed - 10 sq.mm 1 m

PC0224

Coefficient for per m of PC0224

Code Description Quant Units

MT4334Power Cables (1.1kV) 3- Core Copper-Armoured, PVC insulated & sheathed - 16 sq.mm 1 m

PC0225

Coefficient for per m of PC0225

Code Description Quant Units

MT4335Power Cables (1.1kV) 3- Core Copper-Armoured, PVC insulated & sheathed - 25 sq.mm

PC0235

Coefficient for per each of PC0235

Code Description Quant Units MT4725 Single Compression Gland, heavy duty brass - 20mm dia 1 each

PC0236

Coefficient for per each of PC0236

Code Description Quant Units MT4726 Single Compression Gland, heavy duty brass - 22mm dia 1 each

PC0237

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 25 sq.mm

Supplying of heavy duty brass single compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 20mm dia, 4sq.mm

Supplying of heavy duty brass single compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 22mm dia, 6sq.mm

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 6 sq.mm

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 10 sq.mm

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 16 sq.mm

Supplying of heavy duty brass single compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 25mm dia, 10sq.mm

Supplying of 2- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 16 sq.mm

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 2.5 sq.mm

Supplying of 3- Core 1.1KV grade PVC insulated and sheathed Copper conductor armoured power cables - 4 sq.mm

Page 246: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 247

Department of Engineering Services, MoWHS

Coefficient for per each of PC0237

Code Description Quant Units MT4727 Single Compression Gland, heavy duty brass - 25mm dia 1 each

PC0238

Coefficient for per each of PC0238

Code Description Quant Units MT4728 Single Compression Gland, heavy duty brass - 27mm dia 1 each

PC0239

Coefficient for per each of PC0239

Code Description Quant Units MT4729 Single Compression Gland, heavy duty brass - 29mm dia 1 each

PC0250

Coefficient for per each of PC0250

Code Description Quant Units MT4730 Single Compression Gland, heavy duty brass - 33mm dia 1 each

PC0251

Coefficient for per each of PC0251

Code Description Quant Units MT4731 Single Compression Gland, heavy duty brass - 35mm dia 1 each

PC0252

Coefficient for per each of PC0252

Code Description Quant Units MT4732 Single Compression Gland, heavy duty brass - 38mm dia 1 each

PC0253

Coefficient for per each of PC0253

Code Description Quant Units MT4733 Single Compression Gland, heavy duty brass - 40mm dia 1 each

PC0254

Coefficient for per each of PC0254

Code Description Quant Units MT4734 Single Compression Gland, heavy duty brass - 45mm dia 1 each

PC0255

Coefficient for per each of PC0255

Code Description Quant Units MT4735 Single Compression Gland, heavy duty brass - 50mm dia 1 each

PC0256

Coefficient for per each of PC0256

Code Description Quant Units MT4736 Single Compression Gland, heavy duty brass - 55mm dia 1 each

Supplying of heavy duty brass single compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 27mm dia, 16sq.mm

Supplying of heavy duty brass single compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 29mm dia, 25sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 33mm dia, 35sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 35mm dia, 50sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 38mm dia, 70sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 40mm dia, 95sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 45mm dia, 120sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 50mm dia, 150sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 55mm dia, 185sq.mm

Page 247: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 248

Department of Engineering Services, MoWHS

PC0257

Coefficient for per each of PC0257

Code Description Quant Units MT4737 Single Compression Gland, heavy duty brass - 60mm dia 1 each

PC0258

Coefficient for per each of PC0258

Code Description Quant Units MT4738 Single Compression Gland, heavy duty brass - 63mm dia 1 each

PC0259

Coefficient for per each of PC0259

Code Description Quant Units MT4739 Single Compression Gland, heavy duty brass - 70mm dia 1 each

PC0260

Coefficient for per each of PC0260

Code Description Quant Units MT4740 Single Compression Gland, heavy duty brass - 78mm dia 1 each

PC0261

Coefficient for per each of PC0261

Code Description Quant Units MT4741 Single Compression Gland, heavy duty brass - 82mm dia 1 each

PC0262

Coefficient for per each of PC0262

Code Description Quant Units MT4742 Single Compression Gland, heavy duty brass - 85mm dia 1 each

PC0275

Coefficient for per each of PC0275

Code Description Quant Units MT4755 Double Compression Gland, heavy duty brass - 20mm dia 1 each

PC0276

Coefficient for per each of PC0276

Code Description Quant Units MT4756 Double Compression Gland, heavy duty brass - 22mm dia 1 each

PC0277

Coefficient for per each of PC0277

Code Description Quant Units MT4757 Double Compression Gland, heavy duty brass - 25mm dia 1 each

PC0278

Coefficient for per each of PC0278

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 60mm dia, 225sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 63mm dia, 240sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 70mm dia, 300sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 78mm dia, 400sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 82mm dia, 500sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 85mm dia, 630sq.mm

Supplying of heavy duty brass double compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 20mm dia, 4sq.mm

Supplying of heavy duty brass double compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 22mm dia, 6sq.mm

Supplying of heavy duty brass double compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 25mm dia, 10sq.mm

Supplying of heavy duty brass double compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 27mm dia, 16sq.mm

Page 248: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 249

Department of Engineering Services, MoWHS

Code Description Quant Units MT4758 Double Compression Gland, heavy duty brass - 27mm dia 1 each

PC0279

Coefficient for per each of PC0279

Code Description Quant Units MT4759 Double Compression Gland, heavy duty brass - 29mm dia 1 each

PC0290

Coefficient for per each of PC0290

Code Description Quant Units MT4760 Double Compression Gland, heavy duty brass - 33mm dia 1 each

PC0291

Coefficient for per each of PC0291

Code Description Quant Units MT4761 Double Compression Gland, heavy duty brass - 35mm dia 1 each

PC0292

Coefficient for per each of PC0292

Code Description Quant Units MT4762 Double Compression Gland, heavy duty brass - 38mm dia 1 each

PC0293

Coefficient for per each of PC0293

Code Description Quant Units MT4763 Double Compression Gland, heavy duty brass - 40mm dia 1 each

PC0294

Coefficient for per each of PC0294

Code Description Quant Units MT4764 Double Compression Gland, heavy duty brass - 45mm dia 1 each

PC0295

Coefficient for per each of PC0295

Code Description Quant Units MT4765 Double Compression Gland, heavy duty brass - 50mm dia 1 each

PC0296

Coefficient for per each of PC0296

Code Description Quant Units MT4766 Double Compression Gland, heavy duty brass - 55mm dia 1 each

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 45mm dia, 120sq.mm

Supplying of heavy duty brass double compression gland for 4- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 29mm dia, 25sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 33mm dia, 35sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 35mm dia, 50sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 38mm dia, 70sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 40mm dia, 95sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 50mm dia, 150sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 55mm dia, 185sq.mm

Page 249: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 250

Department of Engineering Services, MoWHS

PC0297

Coefficient for per each of PC0297

Code Description Quant Units MT4767 Double Compression Gland, heavy duty brass - 60mm dia 1 each

PC0298

Coefficient for per each of PC0298

Code Description Quant Units MT4768 Double Compression Gland, heavy duty brass - 63mm dia 1 each

PC0299

Coefficient for per each of PC0299

Code Description Quant Units MT4769 Double Compression Gland, heavy duty brass - 70mm dia 1 each

PC0300

Coefficient for per each of PC0300

Code Description Quant Units MT4770 Double Compression Gland, heavy duty brass - 78mm dia 1 each

PC0301

Coefficient for per each of PC0301

Code Description Quant Units MT4771 Double Compression Gland, heavy duty brass - 82mm dia 1 each

PC0302

Coefficient for per each of PC0302

Code Description Quant Units MT4772 Double Compression Gland, heavy duty brass - 85mm dia 1 each

CHAPTER 19: POWER CABLE LAYING

Coefficient for per m of CL0001

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day LB0077 Labourer 0.68207 day MT6604 Sand 0.0876 cu.m MT6680 Bricks 2nd class 0.01 1000#

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 60mm dia, 225sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 63mm dia, 240sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 78mm dia, 400sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 82mm dia, 500sq.mm

Supplying of heavy duty brass single compression gland for 3.5- Core 1.1KV grade PVC insulated and sheathed Copper/ Aluminium conductor armoured/ un-armoured power cables - 85mm dia, 630sq.mm

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core direct in the ground including excavation, sandcushing, protective covering and refilling the trenches etc. as required - Upto 6sq.mm

CL0001

Page 250: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 251

Department of Engineering Services, MoWHS

Coefficient for per m of CL0002

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day LB0077 Labourer 0.68207 day MT6604 Sand 0.0876 cu.m MT6680 Bricks 2nd class 0.01 1000#

Coefficient for per m of CL0003

Code Description Quant Units LB0056 Wireman Gd.1 0.036 day LB0069 Wireman Gd.2 0.036 day LB0077 Labourer 0.68207 day MT6604 Sand 0.0876 cu.m MT6680 Bricks 2nd class 0.01 1000#

Coefficient for per m of CL0004

Code Description Quant Units LB0056 Wireman Gd.1 0.042 day LB0069 Wireman Gd.2 0.042 day LB0077 Labourer 0.68207 day MT6604 Sand 0.0876 cu.m MT6680 Bricks 2nd class 0.01 1000#

Coefficient for per m of CL0005

Code Description Quant Units LB0056 Wireman Gd.1 0.05 day LB0069 Wireman Gd.2 0.05 day LB0077 Labourer 0.68207 day MT6604 Sand 0.0876 cu.m MT6680 Bricks 2nd class 0.01 1000#

Coefficient for per m of CL0006

Code Description Quant Units LB0056 Wireman Gd.1 0.06 day LB0069 Wireman Gd.2 0.06 day LB0077 Labourer 0.68207 day MT6604 Sand 0.0876 cu.m MT6680 Bricks 2nd class 0.01 1000#

cushing, protective covering and refilling the trenches etc. as required - Above 25sq.mm to 70sq.mm

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core direct in the ground including excavation, sand

cushing, protective covering and refilling the trenches etc. as required - Above 6sq.mm to 25sq.mm

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core direct in the ground including excavation, sand CL0002

CL0003

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core direct in the ground including excavation, sand cushing, protective covering and refilling the trenches etc. as required - Above 70sq.mm to 150sq.mm

CL0004

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core direct in the ground including excavation, sand cushing, protective covering and refilling the trenches etc. as required - Above 150sq.mm to 300sq.mm

CL0005

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core direct in the ground including excavation, sand cushing, protective covering and refilling the trenches etc. as required - Above 300sq.mm to 630sq.mm

CL0006

Page 251: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 252

Department of Engineering Services, MoWHS

Coefficient for per m of CL0020

Code Description Quant Units LB0056 Wireman Gd.1 0.015 day LB0069 Wireman Gd.2 0.015 day LB0077 Labourer 0.34103 day MT6604 Sand 0.046 cu.m MT6680 Bricks 2nd class 0.01 1000#

Coefficient for per m of CL0021

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0069 Wireman Gd.2 0.025 day LB0077 Labourer 0.34103 day MT6604 Sand 0.046 cu.m MT6680 Bricks 2nd class 0.01 1000#

Coefficient for per m of CL0022

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day LB0077 Labourer 0.34103 day MT6604 Sand 0.046 cu.m MT6680 Bricks 2nd class 0.01 1000#

Coefficient for per m of CL0023

Code Description Quant Units LB0056 Wireman Gd.1 0.036 day LB0069 Wireman Gd.2 0.036 day LB0077 Labourer 0.34103 day MT6604 Sand 0.046 cu.m MT6680 Bricks 2nd class 0.01 1000#

Coefficient for per m of CL0024

Code Description Quant Units LB0056 Wireman Gd.1 0.044 day LB0069 Wireman Gd.2 0.044 day LB0077 Labourer 0.34103 day MT6604 Sand 0.046 cu.m MT6680 Bricks 2nd class 0.01 1000#

Coefficient for per m of CL0040

Code Description Quant Units LB0056 Wireman Gd.1 0.01 day LB0069 Wireman Gd.2 0.01 day

Extra for laying of one number additional PVC insulated and sheathed power cable copper/aluminium, armoured/un-armoured 1.1KV single core to four core direct in the ground in the same trench in one tier horizontal formation including excavation, sand cushing, protective covering and refilling trenches etc. as required - Upto 6sq.mm

CL0020

Extra for laying of one number additional PVC insulated and sheathed power cable copper/aluminium, armoured/un-armoured 1.1KV single core to four core direct in the ground in the same trench in one tier horizontal formation including excavation, sand cushing, protective covering and refilling the as required - Above 6sq.mm to 25sq.mm

CL0021

Extra for laying of one number additional PVC insulated and sheathed power cable copper/aluminium, armoured/un-armoured 1.1KV single core to four core direct in the ground in the same trench in one tier horizontal formation including excavation, sand cushing, protective covering and refilling the

CL0022

Extra for laying of one number additional PVC insulated and sheathed power cable copper/aluminium, armoured/un-armoured 1.1KV single core to four core direct in the ground in the same trench in one tier horizontal formation including excavation, sand cushing, protective covering and refilling the as required - Above 70sq.mm to 150sq.mm

CL0023

Extra for laying of one number additional PVC insulated and sheathed power cable copper/aluminium, armoured/un-armoured 1.1KV single core to four core direct in the ground in the same trench in one tier horizontal formation including excavation, sand cushing,protective covering and refilling the as required - Above 150sq.mm to 300sq.mm

CL0024

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting RCC/ Hume/ Stone ware/ G.I pipes as required - Upto 6sq.mm

CL0040

Page 252: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 253

Department of Engineering Services, MoWHS

Coefficient for per m of CL0041

Code Description Quant Units LB0056 Wireman Gd.1 0.013 day LB0069 Wireman Gd.2 0.013 day

Coefficient for per m of CL0042

Code Description Quant Units LB0056 Wireman Gd.1 0.017 day LB0069 Wireman Gd.2 0.017 day

Coefficient for per m of CL0043

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day

Coefficient for per m of CL0044

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day

Coefficient for per m of CL0045

Code Description Quant Units LB0056 Wireman Gd.1 0.035 day LB0069 Wireman Gd.2 0.035 day

Coefficient for per m of CL0055

Code Description Quant Units LB0056 Wireman Gd.1 0.01 day LB0069 Wireman Gd.2 0.01 day

Coefficient for per m of CL0056

Code Description Quant Units LB0056 Wireman Gd.1 0.013 day LB0069 Wireman Gd.2 0.013 day

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting RCC/ Hume/ Stone ware/ G.I pipes as required - Above 6sq.mm to 25sq.mm

CL0041

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting RCC/ Hume/ Stone ware/ G.I pipes as required - Above 25sq.mm to 70sq.mm

CL0042

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting RCC/ Hume/ Stone ware/ G.I pipes as required - Above 70sq.mm to 150sq.mm

CL0043

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting RCC/ Hume/ Stone ware/ G.I pipes as required - Above 150sq.mm to 300sq.mm

CL0044

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting RCC/ Hume/ Stone ware/ G.I pipes as required - Above 300sq.mm to 630sq.mm

CL0045

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting masonry open duct as required - Upto 6sq.mm

CL0055

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting masonry open duct as required - Above 6sq.mm to 25sq.mm

CL0056

Page 253: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 254

Department of Engineering Services, MoWHS

Coefficient for per m of CL0057

Code Description Quant Units LB0056 Wireman Gd.1 0.017 day LB0069 Wireman Gd.2 0.017 day

Coefficient for per m of CL0058

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0069 Wireman Gd.2 0.022 day

Coefficient for per m of CL0059

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0069 Wireman Gd.2 0.028 day

Coefficient for per m of CL0060

Code Description Quant Units LB0056 Wireman Gd.1 0.035 day LB0069 Wireman Gd.2 0.035 day

CL0070

Coefficient for per each of CL0070

Code Description Quant Units LB0036 Mason Gd.1 0.00187 day LB0039 Work Supervisor (Lajab) 0.0015 day LB0051 Mason Gd.2 0.00187 day LB0053 Plant Operator Gd.3 0.0021 day LB0056 Wireman Gd.1 0.167 day LB0069 Wireman Gd.2 0.167 day LB0077 Labourer 0.25188 day MP0001 Concrete Mixer 0.0021 day MP0002 Concrete Vibrator 0.0021 day MT6604 Sand 0.01335 cu.m MT6623 Stone Aggregates - 20mm 0.0267 cu.m MT6681 Grey Cement 0.00964 tonne

Coefficient for per each of CL0080

Code Description Quant Units LB0036 Mason Gd.1 0.00008 day LB0039 Work Supervisor (Lajab) 0.00007 day LB0051 Mason Gd.2 0.00008 day LB0053 Plant Operator Gd.3 0.00009 day LB0056 Wireman Gd.1 0.167 day

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting masonry open duct as required - Above 25sq.mm to 70sq.mm

CL0057

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting masonry open duct as required - Above 70sq.mm to 150sq.mm

CL0058

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting masonry open duct as required - Above 150sq.mm to 300sq.mm

CL0059

Laying of one number PVC insulated and sheathed power cable copper/aluminium, armoured/ un-armoured 1.1KV single core to four core in the exisiting masonry open duct as required - Above 300sq.mm to 630sq.mm

CL0060

Providing and making route marker of size 600x600mm at bottom and 500x500mm at top with a thickness of 100mm including inscreption as required - With cement concrete 1:2:4, 20mm stone aggregate

Providing and making route marker of size 150x100x6mm with necessary nuts & bolts 100mm long 10mm dia with washer embeded in cement concrete 1:2:4, 20mm stone aggregate including inscription as required - With cement concrete 1:2:4, 20mm stone aggregate

CL0080

Page 254: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 255

Department of Engineering Services, MoWHS

LB0069 Wireman Gd.2 0.167 day LB0077 Labourer 0.00404 day MT4785 C.I Route Marker, 150x100x6mm 1 each MP0001 Concrete Mixer 0.00009 day MP0002 Concrete Vibrator 0.00009 day MT6604 Sand 0.00058 cu.m MT6623 Stone Aggregates - 20mm 0.00116 cu.m MT6681 Grey Cement 0.00042 tonne

Coefficient for per each of CL0090

Code Description Quant Units LB0024 Lineman Gd.1 0.75 day LB0069 Wireman Gd.2 0.75 day MT4786 Straight through cable joint box 1 each

Coefficient for per each of CL0091

Code Description Quant Units LB0024 Lineman Gd.1 1 day LB0069 Wireman Gd.2 1 day MT4786 Straight through cable joint box 1 each

Coefficient for per each of CL0092

Code Description Quant Units LB0024 Lineman Gd.1 1.5 day LB0069 Wireman Gd.2 1.5 day MT4786 Straight through cable joint box 1 each

Coefficient for per each of CL0093

Code Description Quant Units LB0024 Lineman Gd.1 1.75 day LB0069 Wireman Gd.2 1.75 day MT4786 Straight through cable joint box 1 each

Coefficient for per each of CL0094

Code Description Quant Units LB0024 Lineman Gd.1 1.1 day LB0069 Wireman Gd.2 1.1 day MT4786 Straight through cable joint box 1 each

Coefficient for per each of CL0095

Code Description Quant Units LB0024 Lineman Gd.1 1.6 day LB0069 Wireman Gd.2 1.6 day MT4786 Straight through cable joint box 1 each

Providing and fixing straight through joint box including ferrules and other jointing materials for under- ground PVC sheathed cable 1.1KV including making joints and filling with bitumenous compound for the aluminium conductor cable - 4-Core, 50/70/95sq.mm

CL0095

Providing and fixing straight through joint box including ferrules and other jointing materials for under- ground PVC sheathed cable 1.1KV including making joints and filling with bitumenous compound for the aluminium conductor cable - 2-Core, 6/10/16sq.mm

CL0090

Providing and fixing straight through joint box including ferrules and other jointing materials for under- ground PVC sheathed cable 1.1KV including making joints and filling with bitumenous compound for the aluminium conductor cable - 3.5-Core, 25/35/50sq.mm

CL0091

Providing and fixing straight through joint box including ferrules and other jointing materials for under- ground PVC sheathed cable 1.1KV including making joints and filling with bitumenous compound for the aluminium conductor cable - 3.5-Core, 70/95/120sq.mm

CL0092

Providing and fixing straight through joint box including ferrules and other jointing materials for under- ground PVC sheathed cable 1.1KV including making joints and filling with bitumenous compound for the aluminium conductor cable - 3.5-Core, 240/300sq.mm

CL0093

Providing and fixing straight through joint box including ferrules and other jointing materials for under- ground PVC sheathed cable 1.1KV including making joints and filling with bitumenous compound for the aluminium conductor cable - 4-Core, 16/25/35sq.mm

CL0094

Page 255: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 256

Department of Engineering Services, MoWHS

Coefficient for per each of CL0096

Code Description Quant Units LB0024 Lineman Gd.1 1.8 day LB0069 Wireman Gd.2 1.8 day MT4786 Straight through cable joint box 1 each

Coefficient for per each of CL0110

Code Description Quant Units LB0024 Lineman Gd.1 0.125 day LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4680 Ferrule type brass thimble - 32A 2 each MT4700 Ferrule type aluminium alloy thimble - 16A 2 each

Coefficient for per each of CL0111

Code Description Quant Units LB0024 Lineman Gd.1 0.167 day LB0056 Wireman Gd.1 0.167 day LB0069 Wireman Gd.2 0.167 day MT4682 Ferrule type brass thimble - 50A 2 each MT4683 Ferrule type brass thimble - 63A 2 each

Coefficient for per each of CL0112

Code Description Quant Units LB0024 Lineman Gd.1 0.25 day LB0056 Wireman Gd.1 0.25 day LB0069 Wireman Gd.2 0.25 day MT4705 Ferrule type aluminium alloy thimble - 100A 2 each MT4707 Ferrule type aluminium alloy thimble - 130A 2 each

Coefficient for per each of CL0113

Code Description Quant Units LB0024 Lineman Gd.1 0.33 day LB0056 Wireman Gd.1 0.33 day LB0069 Wireman Gd.2 0.33 day MT4708 Ferrule type aluminium alloy thimble - 150A 2 each MT4710 Ferrule type aluminium alloy thimble - 200A 2 each

Coefficient for per each of CL0114

Code Description Quant Units LB0024 Lineman Gd.1 0.5 day

Installation, Testing and Commissioning of end termination with single/double compresion gland for PVC insulated and sheathed aluminium/ copper conductor cable of 1.1KV grade including connections etc. as required - 60/63/70mm dia

CL0114

Installation, Testing and Commissioning of end termination with single/double compresion gland for PVC insulated and sheathed aluminium/ copper conductor cable of 1.1KV grade including connections etc. as required - 35/38/40mm dia

CL0112

Installation, Testing and Commissioning of end termination with single/double compresion gland for PVC insulated and sheathed aluminium/ copper conductor cable of 1.1KV grade including connections etc. as required - 45/50/55mm dia

CL0113

Installation, Testing and Commissioning of end termination with single/double compresion gland for PVC insulated and sheathed aluminium/ copper conductor cable of 1.1KV grade including connections etc. as required - 20/22/25mm dia

CL0110

Installation, Testing and Commissioning of end termination with single/double compresion gland for PVC insulated and sheathed aluminium/ copper conductor cable of 1.1KV grade including connections etc. as required - 27/29/33mm dia

CL0111

Providing and fixing straight through joint box including ferrules and other jointing materials for under- ground PVC sheathed cable 1.1KV including making joints and filling with bitumenous compound for the aluminium conductor cable - 4-Core, 120/150/300sq.mm

CL0096

Page 256: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 257

Department of Engineering Services, MoWHS

LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4710 Ferrule type aluminium alloy thimble - 200A 2 each MT4711 Ferrule type aluminium alloy thimble - 300A 2 each

Coefficient for per each of CL0115

Code Description Quant Units LB0024 Lineman Gd.1 1 day LB0056 Wireman Gd.1 1 day LB0069 Wireman Gd.2 1 day MT4712 Ferrule type aluminium alloy thimble - 330A 2 each MT4713 Ferrule type aluminium alloy thimble - 425A 2 each

CHAPTER 20: CONTROL CABLE

CC0001

Coefficient for per m of CC0001

Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0067 Painter Gd.2 0.009 day LB0077 Labourer 0.024 day

MT4445Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 2-Core 1.01 m

CC0002

Coefficient for per m of CC0002

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.009 day LB0077 Labourer 0.025 day

MT4446Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 3-Core 1.01 m

CC0003

Coefficient for per m of CC0003

Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0067 Painter Gd.2 0.01 day LB0077 Labourer 0.026 day

MT4447Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 4-Core 1.01 m

CC0004

Coefficient for per m of CC0004

Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0067 Painter Gd.2 0.01 day LB0077 Labourer 0.026 day

MT4448Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 5-Core 1.01 m

CC0005

Coefficient for per m of CC0005

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0067 Painter Gd.2 0.011 day LB0077 Labourer 0.028 day

MT4449Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 6-Core 1.01 m

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 2-Core

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 3-Core

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 4-Core

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 5-Core

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 6-Core

Installation, Testing and Commissioning of end termination with single/double compresion gland for PVC insulated and sheathed aluminium/ copper conductor cable of 1.1KV grade including connections etc. as required - 78/82/85mm dia

CL0115

Page 257: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 258

Department of Engineering Services, MoWHS

CC0006

Coefficient for per m of CC0006

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0067 Painter Gd.2 0.011 day LB0077 Labourer 0.028 day

MT4450Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 7-Core 1.01 m

CC0007

Coefficient for per m of CC0007

Code Description Quant Units LB0056 Wireman Gd.1 0.031 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.031 day

MT4451Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 10-Core 1.01 m

CC0008

Coefficient for per m of CC0008

Code Description Quant Units LB0056 Wireman Gd.1 0.029 day LB0067 Painter Gd.2 0.011 day LB0077 Labourer 0.029 day

MT4452Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 12-Core 1.01 m

CC0009

Coefficient for per m of CC0009

Code Description Quant Units LB0056 Wireman Gd.1 0.031 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.031 day

MT4453Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 14-Core 1.01 m

CC0010

Coefficient for per m of CC0010

Code Description Quant Units LB0056 Wireman Gd.1 0.032 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.032 day

MT4454Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 16-Core 1.01 m

CC0011

Coefficient for per m of CC0011

Code Description Quant Units LB0056 Wireman Gd.1 0.033 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.033 day

MT4455Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 19-Core 1.01 m

CC0012

Coefficient for per m of CC0012

Code Description Quant Units LB0056 Wireman Gd.1 0.034 day

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 16-Core

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 19-Core

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 24-Core

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 7-Core

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 10-Core

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) -12-Core

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 14-Core

Page 258: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 259

Department of Engineering Services, MoWHS

LB0067 Painter Gd.2 0.013 day LB0077 Labourer 0.034 day

MT4456Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 24-Core 1.01 m

CC0013

Coefficient for per m of CC0013

Code Description Quant Units LB0056 Wireman Gd.1 0.036 day LB0067 Painter Gd.2 0.014 day LB0077 Labourer 0.036 day

MT4457Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 27-Core 1.01 m

CC0014

Coefficient for per m of CC0014

Code Description Quant Units LB0056 Wireman Gd.1 0.036 day LB0067 Painter Gd.2 0.014 day LB0077 Labourer 0.036 day

MT4458Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 30-Core 1.01 m

CC0015

Coefficient for per m of CC0015

Code Description Quant Units LB0056 Wireman Gd.1 0.038 day LB0067 Painter Gd.2 0.014 day LB0077 Labourer 0.038 day

MT4459Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 37-Core 1.01 m

CC0016

Coefficient for per m of CC0016

Code Description Quant Units LB0056 Wireman Gd.1 0.04 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.04 day

MT4460Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 44-Core 1.01 m

CC0017

Coefficient for per m of CC0017

Code Description Quant Units LB0056 Wireman Gd.1 0.041 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.041 day

MT4461Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 52-Core 1.01 m

CC0018

Coefficient for per m of CC0018

Code Description Quant Units LB0056 Wireman Gd.1 0.043 day LB0067 Painter Gd.2 0.016 day LB0077 Labourer 0.043 day

MT4462Control Cables (1.1kV) Copper - 1.5 sq.mm - Armoured, PVC insulated & sheathed - 61-Core 1.01 m

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 52-Core

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 61-Core

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 27-Core

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 30-Core

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 37-Core

Providing & laying PVC insulated & Sheathed Armoured Copper Control Cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) -44-Core

Page 259: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 260

Department of Engineering Services, MoWHS

CC0030

Coefficient for per m of CC0030

Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0067 Painter Gd.2 0.01 day LB0077 Labourer 0.026 day

MT4475Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 2-Core 1.01 m

CC0031

Coefficient for per m of CC0031

Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0067 Painter Gd.2 0.01 day LB0077 Labourer 0.026 day

MT4476Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 3-Core 1.01 m

CC0032

Coefficient for per m of CC0032

Code Description Quant Units LB0056 Wireman Gd.1 0.028 day LB0067 Painter Gd.2 0.011 day LB0077 Labourer 0.028 day

MT4477Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 4-Core 1.01 m

CC0033

Coefficient for per m of CC0033

Code Description Quant Units LB0056 Wireman Gd.1 0.029 day LB0067 Painter Gd.2 0.011 day LB0077 Labourer 0.029 day

MT4478Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 5-Core 1.01 m

CC0034

Coefficient for per m of CC0034

Code Description Quant Units LB0056 Wireman Gd.1 0.031 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.031 day

MT4479Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 6-Core 1.01 m

CC0035

Coefficient for per m of CC0035

Code Description Quant Units LB0056 Wireman Gd.1 0.031 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.031 day

MT4480Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 7-Core 1.01 m

CC0036

Coefficient for per m of CC0036

Code Description Quant Units LB0056 Wireman Gd.1 0.032 day

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 6-Core

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 7-Core

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 10-Core

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 2-Core

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 3-Core

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 4-Core

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 5-Core

Page 260: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 261

Department of Engineering Services, MoWHS

LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.032 day

MT4481Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 10-Core 1.01 m

CC0037

Coefficient for per m of CC0037

Code Description Quant Units LB0056 Wireman Gd.1 0.033 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.033 day

MT4482Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 12-Core 1.01 m

CC0038

Coefficient for per m of CC0038

Code Description Quant Units LB0056 Wireman Gd.1 0.033 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.033 day

MT4483Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 14-Core 1.01 m

CC0039

Coefficient for per m of CC0039

Code Description Quant Units LB0056 Wireman Gd.1 0.035 day LB0067 Painter Gd.2 0.013 day LB0077 Labourer 0.035 day

MT4484Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 16-Core 1.01 m

CC0040

Coefficient for per m of CC0040

Code Description Quant Units LB0056 Wireman Gd.1 0.035 day LB0067 Painter Gd.2 0.013 day LB0077 Labourer 0.035 day

MT4485Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 19-Core 1.01 m

CC0041

Coefficient for per m of CC0041

Code Description Quant Units LB0056 Wireman Gd.1 0.038 day LB0067 Painter Gd.2 0.014 day LB0077 Labourer 0.038 day

MT4486Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 24-Core 1.01 m

CC0042

Coefficient for per m of CC0042

Code Description Quant Units LB0056 Wireman Gd.1 0.039 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.039 day

MT4487Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 27-Core 1.01 m

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 12-Core

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 14-Core

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 16-Core

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 19-Core

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 24-Core

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 27-Core

Page 261: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 262

Department of Engineering Services, MoWHS

CC043

Coefficient for per m of CC0043

Code Description Quant Units LB0056 Wireman Gd.1 0.04 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.04 day

MT4488Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 30-Core 1.01 m

CC0044

Coefficient for per m of CC0044

Code Description Quant Units LB0056 Wireman Gd.1 0.041 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.041 day

MT4489Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 37-Core 1.01 m

CC0045

Coefficient for per m of CC0045

Code Description Quant Units LB0056 Wireman Gd.1 0.044 day LB0067 Painter Gd.2 0.017 day LB0077 Labourer 0.044 day

MT4490Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 44-Core 1.01 m

CC0046

Coefficient for per m of CC0046

Code Description Quant Units LB0056 Wireman Gd.1 0.044 day LB0067 Painter Gd.2 0.017 day LB0077 Labourer 0.044 day

MT4491Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 52-Core 1.01 m

CC0047

Coefficient for per m of CC0047

Code Description Quant Units LB0056 Wireman Gd.1 0.045 day LB0067 Painter Gd.2 0.017 day LB0077 Labourer 0.045 day

MT4492Control Cables (1.1kV) Copper - 2.5 sq.mm - Armoured, PVC insulated & sheathed - 61-Core 1.01 m

CC0060

Coefficient for per m of CC0060

Code Description Quant Units LB0056 Wireman Gd.1 0.017 day LB0067 Painter Gd.2 0.006 day LB0077 Labourer 0.017 day

MT4505Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 2-Core 1.01 m

CC0061

Coefficient for per m of CC0061

Code Description Quant Units LB0056 Wireman Gd.1 0.019 day

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 3-Core

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 30-Core

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 37-Core

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 44-Core

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 52-Core

Providing & laying PVC insulated & Sheathed Armoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 61-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 2-Core

Page 262: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 263

Department of Engineering Services, MoWHS

LB0067 Painter Gd.2 0.007 day LB0077 Labourer 0.019 day

MT4506Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 3-Core 1.01 m

CC0062

Coefficient for per m of CC0062

Code Description Quant Units LB0056 Wireman Gd.1 0.019 day LB0067 Painter Gd.2 0.007 day LB0077 Labourer 0.019 day

MT4507Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 4-Core 1.01 m

CC0063

Coefficient for per m of CC0063

Code Description Quant Units LB0056 Wireman Gd.1 0.021 day LB0067 Painter Gd.2 0.008 day LB0077 Labourer 0.021 day

MT4508Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 5-Core 1.01 m

CC0064

Coefficient for per m of CC0064

Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0067 Painter Gd.2 0.009 day LB0077 Labourer 0.023 day

MT4509Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 6-Core 1.01 m

CC0065

Coefficient for per m of CC0065

Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0067 Painter Gd.2 0.009 day LB0077 Labourer 0.023 day

MT4510Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 7-Core 1.01 m

CC0066

Coefficient for per m of CC0066

Code Description Quant Units LB0056 Wireman Gd.1 0.026 day LB0067 Painter Gd.2 0.01 day LB0077 Labourer 0.026 day

MT4511Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 10-Core 1.01 m

CC0067

Coefficient for per m of CC0067

Code Description Quant Units LB0056 Wireman Gd.1 0.027 day LB0067 Painter Gd.2 0.01 day LB0077 Labourer 0.027 day

MT4512Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 12-Core 1.01 m

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 12-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 4-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 5-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 6-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 7-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 10-Core

Page 263: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 264

Department of Engineering Services, MoWHS

CC0068

Coefficient for per m of CC0068

Code Description Quant Units LB0056 Wireman Gd.1 0.029 day LB0067 Painter Gd.2 0.011 day LB0077 Labourer 0.029 day

MT4513Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 14-Core 1.01 m

CC0069

Coefficient for per m of CC0069

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.011 day LB0077 Labourer 0.03 day

MT4514Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 16-Core 1.01 m

CC0070

Coefficient for per m of CC0070

Code Description Quant Units LB0056 Wireman Gd.1 0.031 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.031 day

MT4515Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 19-Core 1.01 m

CC0071

Coefficient for per m of CC0071

Code Description Quant Units LB0056 Wireman Gd.1 0.034 day LB0067 Painter Gd.2 0.013 day LB0077 Labourer 0.034 day

MT4516Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 24-Core 1.01 m

CC0072

Coefficient for per m of CC0072

Code Description Quant Units LB0056 Wireman Gd.1 0.034 day LB0067 Painter Gd.2 0.013 day LB0077 Labourer 0.034 day

MT4517Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 27-Core 1.01 m

CC0073

Coefficient for per m of CC0073

Code Description Quant Units LB0056 Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & she 0.035 day LB0067 Painter Gd.2 0.013 day LB0077 Labourer 0.035 day

MT4518Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 30-Core 1.01 m

CC0074

Coefficient for per m of CC0074

Code Description Quant Units LB0056 Wireman Gd.1 0.036 day LB0067 Painter Gd.2 0.014 day

LB0077 Labourer 0.036 day

MT4519Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 37-Core 1.01 m

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 30-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 37-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 14-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 16-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 19-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 24-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 27-Core

Page 264: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 265

Department of Engineering Services, MoWHS

CC0075

Coefficient for per m of CC0075

Code Description Quant Units LB0056 Wireman Gd.1 0.039 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.039 day

MT4520Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 44-Core 1.01 m

CC0076

Coefficient for per m of CC0076

Code Description Quant Units LB0056 Wireman Gd.1 0.041 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.041 day

MT4521Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 52-Core 1.01 m

CC0077

Coefficient for per m of CC0077

Code Description Quant Units LB0056 Wireman Gd.1 0.041 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.041 day

MT4522Control Cables (1.1kV) Copper - 1.5 sq.mm - Unarmoured, PVC insulated & sheathed - 61-Core 1.01 m

CC0090

Coefficient for per m of CC0090

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0067 Painter Gd.2 0.008 day LB0077 Labourer 0.02 day

MT4535Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 2-Core 1.01 m

CC0091

Coefficient for per m of CC0091

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0067 Painter Gd.2 0.008 day LB0077 Labourer 0.02 day

MT4536Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 3-Core 1.01 m

CC0092

Coefficient for per m of CC0092

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.008 day LB0077 Labourer 0.022 day

MT4537Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 4-Core 1.01 m

CC0093

Coefficient for per m of CC0093

Code Description Quant Units LB0056 Wireman Gd.1 0.023 day LB0067 Painter Gd.2 0.009 day LB0077 Labourer 0.023 day MT4538 Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & she 1.01 m

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 3-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 4-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 5-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 44-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 52-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 1.5 sq.mm (excluding cost of trenches/ducts) - 61-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 2-Core

Page 265: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 266

Department of Engineering Services, MoWHS

CC0094

Coefficient for per m of CC0094

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.009 day LB0077 Labourer 0.025 day

MT4539Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 6-Core 1.01 m

CC0095

Coefficient for per m of CC0095

Code Description Quant Units LB0056 Wireman Gd.1 0.025 day LB0067 Painter Gd.2 0.009 day LB0077 Labourer 0.025 day

MT4540Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 7-Core 1.01 m

CC0096

Coefficient for per m of CC0096

Code Description Quant Units LB0056 Wireman Gd.1 0.029 day LB0067 Painter Gd.2 0.011 day LB0077 Labourer 0.029 day

MT4541Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 10-Core 1.01 m

CC0097

Coefficient for per m of CC0097

Code Description Quant Units LB0056 Wireman Gd.1 0.031 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer (Male) 0.031 day

MT4542Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 12-Core 1.01 m

CC0098

Coefficient for per m of CC0098

Code Description Quant Units LB0056 Wireman Gd.1 0.032 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.032 day

MT4543Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 14-Core 1.01 m

CC0099

Coefficient for per m of CC0099

Code Description Quant Units LB0056 Wireman Gd.1 0.033 day LB0067 Painter Gd.2 0.012 day LB0077 Labourer 0.033 day

MT4544Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 16-Core 1.01 m

CC0100

Coefficient for per m of CC0100

Code Description Quant Units LB0056 Wireman Gd.1 0.034 day LB0067 Painter Gd.2 0.013 day LB0077 Labourer 0.034 day

MT4545Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 19-Core 1.01 m

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 12-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 14-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 16-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 19-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 6-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 7-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 10-Core

Page 266: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 267

Department of Engineering Services, MoWHS

CC0101

Coefficient for per m of CC0101

Code Description Quant Units LB0056 Wireman Gd.1 0.037 day LB0067 Painter Gd.2 0.014 day LB0077 Labourer 0.037 day

MT4546Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 24-Core 1.01 m

CC0102

Coefficient for per m of CC0102

Code Description Quant Units LB0056 Wireman Gd.1 0.037 day LB0067 Painter Gd.2 0.014 day LB0077 Labourer 0.037 day

MT4547Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 27-Core 1.01 m

CC0103

Coefficient for per m of CC0103

Code Description Quant Units LB0056 Wireman Gd.1 0.039 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.039 day

MT4548Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 30-Core 1.01 m

CC0104

Coefficient for per m of CC0104

Code Description Quant Units LB0056 Wireman Gd.1 0.04 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.04 day

MT4549Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 37-Core 1.01 m

CC0105

Coefficient for per m of CC0105

Code Description Quant Units LB0056 Wireman Gd.1 0.039 day LB0067 Painter Gd.2 0.015 day LB0077 Labourer 0.039 day

MT4550Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 44-Core 1.01 m

CC0106

Coefficient for per m of CC0106

Code Description Quant Units LB0056 Wireman Gd.1 0.044 day LB0067 Painter Gd.2 0.017 day LB0077 Labourer 0.044 day

MT4551Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 52-Core 1.01 m

CC0107

Coefficient for per m of CC0107

Code Description Quant Units LB0056 Wireman Gd.1 0.045 day

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 30-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 37-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 44-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 52-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 24-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 27-Core

Providing & laying PVC insulated & Sheathed Unarmoured Copper control cable, 660/1100V - 2.5 sq.mm (excluding cost of trenches/ducts) - 61-Core

Page 267: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 268

Department of Engineering Services, MoWHS

LB0067 Painter Gd.2 0.017 day LB0077 Labourer 0.045 day

MT4552Control Cables (1.1kV) Copper - 2.5 sq.mm - Unarmoured, PVC insulated & sheathed - 61-Core 1.01 m

CHAPTER 21: POLE & ACCESSORIES

Coefficient for per each of PA0001

Code Description Quant Units MT6450 Steel Tubular Pole with base plate - 5.5m, 4.5mm thick 1 each

Coefficient for per each of PA0002

Code Description Quant Units MT6451 Steel Tubular Pole with base plate - 5.5m, 4.8mm thick 1 each

Coefficient for per each of PA0003

Code Description Quant Units MT6452 Steel Tubular Pole with base plate - 5.5m, 5.4mm thick 1 each

Coefficient for per each of PA0004

Code Description Quant Units

MT6468Swaged Street Light Steel Tubular Pole (410 MPa) with base plate - 8.5m, 151 kg 1 each

Coefficient for per each of PA0005

Code Description Quant Units

MT6466Swaged Street Light Steel Tubular Pole (410 MPa) with base plate - 8.5m, 148 kg 1 each

Coefficient for per each of PA0006

Code Description Quant Units

MT6467Swaged Street Light Steel Tubular Pole (410 MPa) with base plate -8.5m, 141 kg 1 each

Coefficient for per each of PA0020

Code Description Quant Units LB0024 Lineman Gd.1 0.033 day LB0033 Carpenter Gd.2 0.2106 day LB0036 Mason Gd.1 0.00845 day LB0039 Work Supervisor (Lajab) 0.00676 day LB0051 Mason Gd.2 0.04145 day LB0053 Plant Operator Gd.3 0.00946 day LB0069 Wireman Gd.2 0.033 day

as required - 5.5m, 5.4mm thick

Supplying of street light/compound light MS tubular pole 50/60mm outer dia having a base plate 250x250x5.4mm, entry hole of 40mm dia 1.1m from bottom and strude bolt as earth terminal complete

complete as required - 5.5m, 4.8mm thick

Supplying of street light/compound light MS tubular pole 50/60mm outer dia having a base plate 250x250x5.4mm, entry hole of 40mm dia 1.1m from bottom and strude bolt as earth terminal complete as required - 8.5m, 141kg

PA0006

Errection of steel tubular pole 5.5m length with 40mm dia MS sleeve as inlet of power cable in cement concrete 1:3:6, 40mm stone aggregate foundation with cement concrete base 0.47mx0.47mx75mm thick 1:4:8 including excavation, centering & shuttering, and refilling, providing props for pole etc. complete as required - At dead end

PA0020

Supplying of street light/compound light MS tubular pole 50/60mm outer dia having a base plate 250x250x5.4mm, entry hole of 40mm dia 1.1m from bottom and strude bolt as earth terminal complete as required - 8.5m, 151kg

PA0004

Supplying of street light/compound light MS tubular pole 50/60mm outer dia having a base plate 250x250x5.4mm, entry hole of 40mm dia 1.1m from bottom and strude bolt as earth terminal complete as required - 8.5m, 148kg

PA0005

PA0001

PA0002

PA0003

Supplying of street light/compound light MS tubular pole 50/60mm outer dia having a base plate 250x250x5.4mm, entry hole of 40mm dia 1.1m from bottom and strude bolt as earth terminal complete as required - 5.5m, 4.5mm thick

Supplying of street light/compound light MS tubular pole 50/60mm outer dia having a base plate 250x250x5.4mm, entry hole of 40mm dia 1.1m from bottom and strude bolt as earth terminal

Page 268: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 269

Department of Engineering Services, MoWHS

LB0077 Labourer 0.65518 day MP0001 Concrete Mixer 0.00946 day MP0002 Concrete Vibrator 0.00946 day MT6600 Ballies 75 to 125mm dia 0.567 m MT6601 Rough-sawn timber (Mixed Conifer) 0.01823 cu.m MT6604 Sand 0.06351 cu.m MT6621 Stone Aggregates - 40mm 0.12026 cu.m MT6681 Grey Cement 0.02822 tonne

Coefficient for per each of PA0021

Code Description Quant Units LB0024 Lineman Gd.1 0.033 day LB0033 Carpenter Gd.2 0.2106 day LB0036 Mason Gd.1 0.00835 day LB0039 Work Supervisor (Lajab) 0.00668 day LB0051 Mason Gd.2 0.04135 day LB0053 Plant Operator Gd.3 0.00936 day LB0069 Wireman Gd.2 0.033 day LB0077 Labourer 0.65193 day MP0001 Concrete Mixer 0.00936 day MP0002 Concrete Vibrator 0.00936 day MT6600 Ballies 75 to 125mm dia 0.567 m MT6601 Rough-sawn timber (Mixed Conifer) 0.01823 cu.m MT6604 Sand 0.06282 cu.m MT6621 Stone Aggregates - 40mm 0.11895 cu.m MT6681 Grey Cement 0.0279 tonne

Coefficient for per each of PA0022

Code Description Quant Units LB0024 Lineman Gd.1 0.033 day LB0033 Carpenter Gd.2 0.2106 day LB0036 Mason Gd.1 0.00826 day LB0039 Work Supervisor (Lajab) 0.00661 day LB0051 Mason Gd.2 0.04126 day LB0053 Plant Operator Gd.3 0.00925 day LB0069 Wireman Gd.2 0.033 day LB0077 Labourer 0.65193 day MP0001 Concrete Mixer 0.00925 day MP0002 Concrete Vibrator 0.00925 day MT6600 Ballies 75 to 125mm dia 0.567 m MT6601 Rough-sawn timber (Mixed Conifer) 0.01823 cu.m MT6604 Sand 0.06213 cu.m MT6621 Stone Aggregates - 40mm 0.11764 cu.m MT6681 Grey Cement 0.02757 tonne

Coefficient for per each of PA0035

Code Description Quant Units LB0024 Lineman Gd.1 0.033 day LB0033 Carpenter Gd.2 0.57564 day LB0036 Mason Gd.1 0.03141 day LB0039 Work Supervisor (Lajab) 0.02513 day

1:4:8 including excavation, centering & shuttering, and refilling, providing props for pole etc. complete as required - At dead end

Errection of steel tubular pole 8.5m length with 40mm dia MS sleeve as inlet of power cable in cement concrete 1:3:6, 40mm stone aggregate foundation with cement concrete base 0.47mx0.47mx75mm thick PA0035

Errection of steel tubular pole 5.5m length with 40mm dia MS sleeve as inlet of power cable in cement concrete 1:3:6, 40mm stone aggregate foundation with cement concrete base 0.47mx0.47mx75mm thick 1:4:8 including excavation, centering & shuttering, and refilling, providing props for pole etc. complete as required - At middle

PA0021

Errection of steel tubular pole 5.5m length with 40mm dia MS sleeve as inlet of power cable in cement concrete 1:3:6, 40mm stone aggregate foundation with cement concrete base 0.47mx0.47mx75mm thick 1:4:8 including excavation, centering & shuttering, and refilling, providing props for pole etc. complete as required - Junction of three way

PA0022

Page 269: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 270

Department of Engineering Services, MoWHS

LB0051 Mason Gd.2 0.06441 day LB0053 Plant Operator Gd.3 0.03518 day LB0069 Wireman Gd.2 0.033 day LB0077 Labourer 2.12231 day MP0001 Concrete Mixer 0.03518 day MP0002 Concrete Vibrator 0.03518 day MT6600 Ballies 75 to 125mm dia 1.5498 m MT6601 Rough-sawn timber (Mixed Conifer) 0.04982 cu.m MT6604 Sand 0.23618 cu.m MT6621 Stone Aggregates - 40mm 0.44723 cu.m MT6681 Grey Cement 0.10733 tonne

Coefficient for per each of PA0036

Code Description Quant Units LB0024 Lineman Gd.1 0.033 day LB0033 Carpenter Gd.2 0.57564 day LB0036 Mason Gd.1 0.03141 day LB0039 Work Supervisor (Lajab) 0.02513 day LB0051 Mason Gd.2 0.06441 day LB0053 Plant Operator Gd.3 0.03518 day LB0069 Wireman Gd.2 0.033 day LB0077 Labourer 2.12231 day MP0001 Concrete Mixer 0.03518 day MP0002 Concrete Vibrator 0.03518 day MT6600 Ballies 75 to 125mm dia 1.5498 m MT6601 Rough-sawn timber (Mixed Conifer) 0.04982 cu.m MT6604 Sand 0.23618 cu.m MT6621 Stone Aggregates - 40mm 0.44723 cu.m MT6681 Grey Cement 0.10733 tonne

Coefficient for per each of PA0037

Code Description Quant Units LB0024 Lineman Gd.1 0.033 day LB0033 Carpenter Gd.2 0.57564 day LB0036 Mason Gd.1 0.03141 day LB0039 Work Supervisor (Lajab) 0.02513 day LB0051 Mason Gd.2 0.06441 day LB0053 Plant Operator Gd.3 0.03518 day LB0069 Wireman Gd.2 0.033 day LB0077 Labourer 2.12231 day MP0001 Concrete Mixer 0.03518 day MP0002 Concrete Vibrator 0.03518 day MT6600 Ballies 75 to 125mm dia 1.5498 m MT6601 Rough-sawn timber (Mixed Conifer) 0.04982 cu.m MT6604 Sand 0.23618 cu.m MT6621 Stone Aggregates - 40mm 0.44723 cu.m MT6681 Grey Cement 0.10733 tonne

Coefficient for per each of PA0050

Code Description Quant Units LB0024 Lineman Gd.1 0.333 day

Errection of steel tubular pole 8.5m length with 40mm dia MS sleeve as inlet of power cable in cement concrete 1:3:6, 40mm stone aggregate foundation with cement concrete base 0.47mx0.47mx75mm thick 1:4:8 including excavation, centering & shuttering, and refilling, providing props for pole etc. complete as required - Junction of three way

PA0037

Errection of junction box and pole cap with arm bracket including wiring with PVC insulated copper conductor cable 1.1KV grade 2x2.5 sq.mm through the existing pole and arm bracket from junction box including erection of street light fixtures, lamps, connection, testing etc. complete as required - Single arm

PA0050

Errection of steel tubular pole 8.5m length with 40mm dia MS sleeve as inlet of power cable in cement concrete 1:3:6, 40mm stone aggregate foundation with cement concrete base 0.47mx0.47mx75mm thick 1:4:8 including excavation, centering & shuttering, and refilling, providing props for pole etc. complete as required - At middle

PA0036

Page 270: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 271

Department of Engineering Services, MoWHS

LB0032 Blacksmith (metal-worker) 0.111 day LB0056 Wireman Gd.1 0.333 day LB0069 Wireman Gd.2 0.333 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 17 m MT6637 Rolled Steel Section 250MPa - Flats 0.455 kg

Coefficient for per each of PA0051

Code Description Quant Units LB0024 Lineman Gd.1 0.5 day LB0032 Blacksmith (metal-worker) 0.111 day LB0056 Wireman Gd.1 0.5 day LB0069 Wireman Gd.2 0.5 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 26 m MT6637 Rolled Steel Section 250MPa - Flats 0.455 kg

Coefficient for per each of PA0052

Code Description Quant Units LB0024 Lineman Gd.1 0.75 day LB0032 Blacksmith (metal-worker) 0.111 day LB0056 Wireman Gd.1 0.75 day LB0069 Wireman Gd.2 0.75 day MT4073 PVC insulated Single Core Copper conductor (1.1KV) - 2.5 sq.mm 35 m MT6637 Rolled Steel Section 250MPa - Flats 0.455 kg

Coefficient for per each of PA0065

Code Description Quant Units LB0024 Lineman Gd.1 0.125 day LB0032 Blacksmith (metal-worker) 0.0833 day LB0056 Wireman Gd.1 0.125 day LB0069 Wireman Gd.2 0.125 day MT4071 PVC insulated Single Core Copper conductor (1.1KV) - 1.5 sq.mm 10 m MT6637 Rolled Steel Section 250MPa - Flats 0.145 kg

PA0075

Coefficient for per each of PA0075

Code Description Quant Units LB0056 Wireman Gd.1 0.167 day LB0069 Wireman Gd.2 0.167 day LB0077 Labourer 1.88053 day MT6530 Wire - GI, 4mm dia (8swg) 5 m MT6557 Accessories - G.I Spike 1.8m 1 each

PA0076

Coefficient for per each of PA0076

Code Description Quant Units LB0056 Wireman Gd.1 0.2 day

Erection of post lamp fixtures including wiring with PVC insulated copper conductor cable 1.1KV grade 2x1.5 sq.mm through the existing pole from junction box including erection of post top lamp fixtures, lamps, connection, testing etc. complete as required - Post top lamp fixtures

PA0065

Providing and installation of street/compound light pole earthing including connections, testing etc. complete as required including excavation and refilling - With G.I earth spike 1.8m

Providing and installation of street/compound light pole earthing including connections, testing etc. complete as required including excavation and refilling - With G.I Wire 8 SWG

Errection of junction box and pole cap with arm bracket including wiring with PVC insulated copper conductor cable 1.1KV grade 2x2.5 sq.mm through the existing pole and arm bracket from junction box including erection of street light fixtures, lamps, connection, testing etc. complete as required - Double arm

PA0051

Errection of junction box and pole cap with arm bracket including wiring with PVC insulated copper conductor cable 1.1KV grade 2x2.5 sq.mm through the existing pole and arm bracket from junction box including erection of street light fixtures, lamps, connection, testing etc. complete as required - Triple arm

PA0052

Page 271: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 272

Department of Engineering Services, MoWHS

LB0069 Wireman Gd.2 0.2 day LB0077 Labourer 1.88053 day MT6530 Wire - GI, 4mm dia (8swg) 12 m

PA0090

Coefficient for per each of PA0090

Code Description Quant Units MT6480 Pole cap wih arm bracket 1.1m and outer dia 50/60mm - Single arm 1 each

PA0091

Coefficient for per each of PA0091

Code Description Quant Units MT6481 Pole cap wih arm bracket 1.1m and outer dia 50/60mm - Double arm 1 each

PA0092

Coefficient for per each of PA0092

Code Description Quant Units MT6482 Pole cap wih arm bracket 1.1m and outer dia 50/60mm - Triple arm 1 each

Coefficient for per each of PA0105

Code Description Quant Units MT6495 MS junction box out door duty, fabricated with 14SWG MS sheet 1 each

CHAPTER 22: TELEPHONE WIRES & CABLES

TC0001

Coefficient for per each of TC0001

Code Description Quant Units LB0056 Wireman Gd.1 0.022 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.022 day MT4595 Telephone wire 0.5mm dia, PVC insulated & sheathed, copper - 2 pair 1.01 m

TC0002

Coefficient for per each of TC0002

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0067 Painter Gd.2 0.005 day LB0069 Wireman Gd.2 0.03 day MT4596 Telephone wire 0.5mm dia, PVC insulated & sheathed, copper - 5 pair 1.01 m

Coefficient for per each of TC0010

Code Description Quant Units LB0056 Wireman Gd.1 0.02 day LB0069 Wireman Gd.2 0.02 day MT4610 Telecommunication Cable 0.5mm dia unarmoured, PVC insulated & sheathed, 1.01 m pair

20 pair

Provide and draw PVC insulated & sheathed copper conductor 0.5mm dia telephone wire in existing surface/ recessed conduit wiring system complete as required - 5 pair

Provide and draw PVC insulated & sheathed copper conductor 0.5mm dia telephone wire in existing surface/ recessed conduit wiring system complete as required - 2 pair

PA0105

TC0010

Supplying of pole cap with arm bracket 1.1m long and outer dia 50/60mm having inner pole and outer tightened bolt etc. complete as required for the top section of pole - Double arm

Supplying of pole cap with arm bracket 1.1m long and outer dia 50/60mm having inner pole and outer tightened bolt etc. complete as required for the top section of pole - Triple arm

Provide and draw Jelly filled Telecommunication cables PVC insulated & sheathed copper conductor 0.5mm dia unarmoured in existing surface/ recessed conduit wiring system complete as required -

Supplying of junction box fabricated with 14SWG MS sheet, removal cover plate with gasket for dust and vermine proof, 2 earthing terminals with nut, bolts and spring washer, 2 entry holes 16mm dia at bottom,32mm dia for cable entry at back , including 4 way terminal block & HRC fuse unit with fuse of 6A with locking arrangement and finish coat painting complete with all accessories as required as per standard drawing - MS junction box out door duty

Supplying of pole cap with arm bracket 1.1m long and outer dia 50/60mm having inner pole and outer tightened bolt etc. complete as required for the top section of pole - Single arm

Page 272: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 273

Department of Engineering Services, MoWHS

Coefficient for per each of TC0011

Code Description Quant Units LB0056 Wireman Gd.1 0.03 day LB0069 Wireman Gd.2 0.03 day MT4611 Telecommunication Cable 0.5mm dia unarmoured, PVC insulated & sheathed, 1.01 m pair

Coefficient for per each of TC0012

Code Description Quant Units LB0056 Wireman Gd.1 0.04 day LB0069 Wireman Gd.2 0.04 day MT4612 Telecommunication Cable 0.5mm dia unarmoured, PVC insulated & sheathed, 1.01 m pair

Coefficient for per each of TC0020

Code Description Quant Units LB0056 Wireman Gd.1 0.024 day LB0069 Wireman Gd.2 0.024 day MT4625 Telecommunication Cable 0.5mm dia armoured, PVC insulated & sheathed, co 1.01 m

Coefficient for per each of TC0021

Code Description Quant Units LB0056 Wireman Gd.1 0.034 day LB0069 Wireman Gd.2 0.034 day MT4626 Telecommunication Cable 0.5mm dia armoured, PVC insulated & sheathed, co 1.01 m

Coefficient for per each of TC0022

Code Description Quant Units LB0056 Wireman Gd.1 0.044 day LB0069 Wireman Gd.2 0.044 day MT4627 Telecommunication Cable 0.5mm dia armoured, PVC insulated & sheathed, co 1.01 m pair

CHAPTER 23: AIR CONDITIONERS

AC0001 Coefficient for per each of AC0001

Code Description Quant Units LB0021 Carpenter Gd.1 1 day LB0077 Labourer 1 day MT6567 Window Type - 1 tonne 1 each

Provide and draw Jelly filled Telecommunication cables PVC insulated & sheathed copper conductor 0.5mm dia unarmoured in existing surface/ recessed conduit wiring system complete as required -

100 pair TC0022

Providing & fixing Window Type Air Conditioners - 1 tonne, window type

20 pair TC0020

Provide and draw Jelly filled Telecommunication cables PVC insulated & sheathed copper conductor 0.5mm dia armoured in existing surface/ recessed conduit wiring system complete as required - 50 pair

TC0021

Provide and draw Jelly filled Telecommunication cables PVC insulated & sheathed copper conductor 0.5mm dia armoured in existing surface/ recessed conduit wiring system complete as required -

50 pair TC0011

Provide and draw Jelly filled Telecommunication cables PVC insulated & sheathed copper conductor 0.5mm dia unarmoured in existing surface/ recessed conduit wiring system complete as required - 100 pair

TC0012

Provide and draw Jelly filled Telecommunication cables PVC insulated & sheathed copper conductor 0.5mm dia armoured in existing surface/ recessed conduit wiring system complete as required -

Page 273: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 274

Department of Engineering Services, MoWHS

AC0002 Coefficient for per each of AC0002

Code Description Quant Units LB0021 Carpenter Gd.1 1 day LB0077 Labourer 1 day MT6566 Window Type - 1.5 tonne 1 each AC0003 Coefficient for per each of AC0003

Code Description Quant Units LB0021 Carpenter Gd.1 1 day LB0077 Labourer 1 day MT6565 Window Type - 2 tonne 1 each AC0015 Coefficient for per each of AC0015

Code Description Quant Units LB0021 Carpenter Gd.1 1 day LB0077 Labourer 1 day MT6587 Splite Type - 1 tonne 1 each AC0016 Coefficient for per each of AC0016

Code Description Quant Units LB0021 Carpenter Gd.1 1 day LB0077 Labourer 1 day MT6586 Splite Type - 1.5 tonne 1 each AC0017 Coefficient for per each of AC0017

Code Description Quant Units LB0021 Carpenter Gd.1 1 day LB0077 Labourer (Male) 1 day MT6585 Splite Type - 2 tonne 1 each

CHAPTER 24: DISMANTLING & DEMOLITION

Coefficient for per point of DS0001

Code Description Quant Units LB0024 Lineman Gd.1 0.0625 day LB0077 Labourer 0.1875 day

Coefficient for per point of DS0002

Code Description Quant Units LB0024 Lineman Gd.1 0.125 day LB0077 Labourer 0.375 day

Dismantling of Electrical wiring including conduits for light, fan, Exhaust fan, call bell, 3 pin 5 ampere plug point, circuit / submain wiring etc and stacking materials within 50m lead including making the surface good: - medium point

DS0002

Dismantling of Electrical wiring including conduits for light, fan, Exhaust fan, call bell, 3 pin 5 ampere plug point, circuit /submain wiring etc and stacking materials within 50m lead including the

Providing & fixing Window Type Air Conditioners - 2 tonne, window type

Providing & fixing Split Type Air Conditioners - 1 tonne, split type

surface good: - short point DS0001

Providing & fixing Window Type Air Conditioners - 1.5 tonne, window type

Providing & fixing Split Type Air Conditioners - 1.5 tonne, split typ

Providing & fixing Split Type Air Conditioners - 2 tonne, split type

Page 274: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 275

Department of Engineering Services, MoWHS

Coefficient for per point of DS0003

Code Description Quant Units LB0024 Lineman Gd.1 0.1875 day LB0077 Labourer 0.5714 day

Coefficient for per m of DS0004

Code Description Quant Units LB0024 Lineman Gd.1 0.045 day LB0077 Labourer 0.0675 day

DS0015

Coefficient for per each of DS0015

Code Description Quant Units LB0024 Lineman Gd.1 0.021 day LB0077 Labourer 0.03125 day

CHAPTER 25: CIVIL WORK

CV0001

Coefficient for per sq.m of CV0001

Code Description Quant Units LB0077 Labourer 0.0339 day

CV0002

Coefficient for per sq.m of CV0002

Code Description Quant Units LB0077 Labourer 0.0476 day

CV0015

Coefficient for per cu.m of CV0015

Code Description Quant Units LB0077 Labourer 0.4588 day

CV0016

Coefficient for per cu.m of CV0016

Code Description Quant Units LB0077 Labourer 0.588 day

CV0017

Coefficient for per cu.m of CV0017

Code Description Quant Units LB0077 Labourer 1.6838 day

Excavation in foundation trenches or drains, width <1.5m, area <10 sq.m in plan, depth >300mm including dressing & ramming, disposal of surplus soil within 50m lead & 1.5m lift - Ordinary Soil

Excavation in foundation trenches or drains, width <1.5m, area <10 sq.m in plan, depth >300mm including dressing & ramming, disposal of surplus soil within 50m lead & 1.5m lift - Hard Soil

Excavation in foundation trenches or drains, width <1.5m, area <10 sq.m in plan, depth >300mm including dressing & ramming, disposal of surplus soil within 50m lead & 1.5m lift - Ordinary rock with out blasting

making the surface good: - Circuit, submain wiring, general wiring

Dismantling of Electrical wiring including conduits for light, fan, Exhaust fan, call bell, 3 pin 5 ampere plug point, circuit /submain wiring etc and stacking materials within 50m lead includingDS0004

Dismantling Electrical fittings, boxes, covers, etc all types and stacking materials within 50m lead including making the surface good: - Pendent/ recessed/ surface

Surface dressing of ground, including removal of vegetations and inequalities < 150mm deep, disposal of rubbish within 50m lead and 1.5m lifts - Ordinary Soil

Surface dressing of ground, including removal of vegetations and inequalities < 150mm deep, disposal of rubbish within 50m lead and 1.5m lifts - Hard Soil

Dismantling of Electrical wiring including conduits for light, fan, Exhaust fan, call bell, 3 pin 5 ampere plug point, circuit /submain wiring etc and stacking materials within 50m lead icludingmaking the surface good: - long point

DS0003

Page 275: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 276

Department of Engineering Services, MoWHS

CV0018

Coefficient for per cu.m of CV0018

Code Description Quant Units LB0032 Blacksmith (metal-worker) 0.044 day LB0051 Mason Gd.2 0.265 day LB0077 Labourer 3.3163 day

Coefficient for per m of CV0030

Code Description Quant Units LB0077 Labourer 0.58232 day

Coefficient for per m of CV0031

Code Description Quant Units LB0077 Labourer 0.90893 day

Coefficient for per m of CV0045

Code Description Quant Units LB0077 Labourer 0.68207 day

Coefficient for per m of CV0046

Code Description Quant Units LB0077 Labourer 1.06462 day

Coefficient for per m of CV0060

Code Description Quant Units LB0077 Labourer 2.35878 day

Coefficient for per m of CV0061

Code Description Quant Units LB0077 Labourer 2.71413 day

Coefficient for per m of CV0075

Code Description Quant Units LB0032 Blacksmith (metal-worker) 0.05148 day LB0051 Mason Gd.2 0.31005 day LB0077 Labourer 4.26881 day

of 50m: Hard Soil - Pipes, cables etc. 80mm to 300mm dia

Hand excavation and refilling in layers < 200mm, of trenches for pipes & sockets, cables, including dressing of sides/ ramming of bottom, depth upto 1.5m, disposal of surplus material within lead

of 50m: Ordinary Soil - Pipes, cables etc. > 300mm dia

Hand excavation and refilling in layers < 200mm, of trenches for pipes & sockets, cables, including dressing of sides/ ramming of bottom, depth upto 1.5m, disposal of surplus material within lead

Hand excavation and refilling in layers < 200mm, of trenches for pipes & sockets, cables, including dressing of sides/ ramming of bottom, depth upto 1.5m, disposal of surplus material within lead of 50m: Ordinary rock - Pipes, cables etc. > 300mm dia

CV0061

Hand excavation and refilling in layers < 200mm, of trenches for pipes & sockets, cables, including dressing of sides/ ramming of bottom, depth upto 1.5m, disposal of surplus material within lead of 50m: Hard rock requiring chiselling - Pipes, cables etc. 80mm to 300mm dia

CV0075

Hand excavation and refilling in layers < 200mm, of trenches for pipes & sockets, cables, including dressing of sides/ ramming of bottom, depth upto 1.5m, disposal of surplus material within lead of 50m: Hard Soil - Pipes, cables etc. > 300mm dia

CV0046

Hand excavation and refilling in layers < 200mm, of trenches for pipes & sockets, cables, including dressing of sides/ ramming of bottom, depth upto 1.5m, disposal of surplus material within lead of 50m: Ordinary rock - Pipes, cables etc. 80mm to 300mm dia

CV0060

CV0030

CV0031

CV0045

Excavation in foundation trenches or drains, width <1.5m, area <10 sq.m in plan, depth >300mm including dressing & ramming, disposal of surplus soil within 50m lead & 1.5m lift - Hard rock requiring chiselling

Hand excavation and refilling in layers < 200mm, of trenches for pipes & sockets, cables, including dressing of sides/ ramming of bottom, depth upto 1.5m, disposal of surplus material within lead of 50m: Ordinary Soil - Pipes, cables etc. 80mm to 300mm dia

Page 276: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 277

Department of Engineering Services, MoWHS

Coefficient for per m of CV0076

Code Description Quant Units LB0032 Blacksmith (metal-worker) 0.05925 day LB0051 Mason Gd.2 0.35685 day LB0077 Labourer 4.91245 day CV0090 Coefficient for per cu.m of CV0090

Code Description Quant Units LB0077 Labourer 0.2955 day CV0091 Coefficient for per cu.m of CV0091

Code Description Quant Units LB0077 Labourer 0.2888 day MT6604 Sand 1 cu.m

CV0105

Coefficient for per sq.m of CV0105

Code Description Quant Units LB0033 Carpenter Gd.2 0.0033 day LB0077 Labourer 0.0069 day MT6600 Ballies 75 to 125mm dia 0.2833 m MT6601 Rough-sawn timber (Mixed Conifer) 0.0087 cu.m

CV0106

Coefficient for per sq.m of CV0106

Code Description Quant Units LB0033 Carpenter Gd.2 0.0069 day LB0077 Labourer 0.0136 day MT6600 Ballies 75 to 125mm dia 0.2833 m MT6601 Rough-sawn timber (Mixed Conifer) 0.0087 cu.m

CV0107

Coefficient for per sq.m of CV0107

Code Description Quant Units LB0033 Carpenter Gd.2 0.0139 day LB0077 Labourer 0.0244 day MT6600 Ballies 75 to 125mm dia 0.2833 m MT6601 Rough-sawn timber (Mixed Conifer) 0.0087 cu.m

CV0120

Coefficient for per sq.m of CV0120

Code Description Quant Units LB0033 Carpenter Gd.2 0.0069 day LB0077 Labourer 0.0139 day MT6600 Ballies 75 to 125mm dia 0.2833 m MT6601 Rough-sawn timber (Mixed Conifer) 0.0257 cu.m

Hand excavation and refilling in layers < 200mm, of trenches for pipes & sockets, cables, including dressing of sides/ ramming of bottom, depth upto 1.5m, disposal of surplus material within lead of 50m: Hard rock requiring chiselling - Pipes, cables etc. > 300mm dia

CV0076

Using selected excavated earth

Using sand

Open timbering over areas including lagging & strutting of trenches, cuts (per sq.m face area timbered) - Depth not exceeding

Open timbering over areas including lagging & strutting of trenches, cuts (per sq.m face area timbered)- 1.5m < depth < 3 m

Open timbering over areas including lagging & strutting of trenches, cuts (per sq.m face area timbered)- Depth > 3 m

Close timbering over areas including lagging & strutting of trenches, cuts ( per sq.m face area timbered)- Depth not exceeding

Page 277: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 278

Department of Engineering Services, MoWHS

CV0121

Coefficient for per sq.m of CV0121

Code Description Quant Units LB0033 Carpenter Gd.2 0.01385 day LB0077 Labourer 0.035 day MT6600 Ballies 75 to 125mm dia 0.2833 m MT6601 Rough-sawn timber (Mixed Conifer) 0.0257 cu.m

CV0122

Coefficient for per sq.m of CV0122

Code Description Quant Units LB0033 Carpenter Gd.2 0.0208 day LB0077 Labourer 0.056 day MT6600 Ballies 75 to 125mm dia 0.2833 m MT6601 Rough-sawn timber (Mixed Conifer) 0.0257 cu.m

CV0135

Coefficient for per cu.m of CV0135

Code Description Quant Units LB0036 Mason Gd.1 0.0625 day LB0039 Work Supervisor (Lajab) 0.05 day LB0051 Mason Gd.2 0.0625 day LB0053 Plant Operator Gd.3 0.07 day LB0077 Labourer 2.2125 day MP0001 Concrete Mixer 0.07 day MP0002 Concrete Vibrator 0.07 day MT6604 Sand 0.445 cu.m MT6623 Stone Aggregates - 20mm 0.89 cu.m MT6681 Grey Cement 0.3213 tonne

CV0136

Coefficient for per cu.m of CV0136

Code Description Quant Units LB0036 Mason Gd.1 0.0625 day LB0039 Work Supervisor (Lajab) 0.05 day LB0051 Mason Gd.2 0.0625 day LB0053 Plant Operator Gd.3 0.07 day LB0077 Labourer 2.2125 day MP0001 Concrete Mixer 0.07 day MP0002 Concrete Vibrator 0.07 day MT6604 Sand 0.445 cu.m MT6621 Stone Aggregates - 40mm 0.89 cu.m MT6681 Grey Cement 0.3213 tonne

CV0137

Coefficient for per cu.m of CV0137

Code Description Quant Units LB0036 Mason Gd.1 0.0625 day LB0039 Work Supervisor (Lajab) 0.05 day LB0051 Mason Gd.2 0.0625 day LB0053 Plant Operator Gd.3 0.07 day LB0077 Labourer 2.2125 day MP0001 Concrete Mixer 0.07 day MP0002 Concrete Vibrator 0.07 day MT6604 Sand 0.47 cu.m MT6621 Stone Aggregates - 40mm 0.89 cu.m MT6681 Grey Cement 0.22 tonne

Close timbering over areas including lagging & strutting of trenches, cuts ( per sq.m face area timbered)- 1.5m < depth < 3m

Close timbering over areas including lagging & strutting of trenches, cuts ( per sq.m face area timbered)- 3m < depth < 4.5m

Providing &laying cement concrete excluding the cost of centering and shuttering - 1:2:4, 20mm aggregates

Providing &laying cement concrete excluding the cost of centering and shuttering - 1:2:4, 40mm aggregates

Providing &laying cement concrete excluding the cost of centering and shuttering - 1:3:6, 40mm aggregates

Page 278: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 279

Department of Engineering Services, MoWHS

CV0138

Coefficient for per cu.m of CV0138

Code Description Quant Units LB0036 Mason Gd.1 0.0625 day LB0039 Work Supervisor (Lajab) 0.05 day LB0051 Mason Gd.2 0.0625 day LB0053 Plant Operator Gd.3 0.07 day LB0077 Labourer 2.2125 day MP0001 Concrete Mixer 0.07 day MP0002 Concrete Vibrator 0.07 day MT6604 Sand 0.47 cu.m MT6620 Stone Aggregates - 50mm 0.89 cu.m MT6681 Grey Cement 0.17 tonne

CV0139

Coefficient for per cu.m of CV0139

Code Description Quant Units LB0036 Mason Gd.1 0.0625 day LB0039 Work Supervisor (Lajab) 0.05 day LB0051 Mason Gd.2 0.0625 day LB0053 Plant Operator Gd.3 0.07 day LB0077 Labourer 2.2125 day MP0001 Concrete Mixer 0.07 day MP0002 Concrete Vibrator 0.07 day MT6604 Sand 0.47 cu.m MT6620 Stone Aggregates - 50mm 0.89 cu.m MT6681 Grey Cement 0.131 tonne

CV0140

Coefficient for per cu.m of CV0140

Code Description Quant Units LB0036 Mason Gd.1 0.0625 day LB0039 Work Supervisor (Lajab) 0.05 day LB0051 Mason Gd.2 0.0625 day LB0053 Plant Operator Gd.3 0.07 day LB0077 Labourer 2.2125 day MP0001 Concrete Mixer 0.07 day MP0002 Concrete Vibrator 0.07 day MT6604 Sand 0.47 cu.m MT6621 Stone Aggregates - 40mm 0.89 cu.m MT6681 Grey Cement 0.131 tonne

CV0150

Coefficient for per sq.m of CV0150

Code Description Quant Units LB0033 Carpenter Gd.2 0.156 day LB0077 Labourer 0.156 day MT6600 Ballies 75 to 125mm dia 0.42 m MT6601 Rough-sawn timber (Mixed Conifer) 0.0135 cu.m CV0160 Coefficient for per cu.m of CV0160

Code Description Quant Units LB0036 Mason Gd.1 0.339 day

Providing &laying cement concrete excluding the cost of centering and shuttering - 1:3:6, 50mm aggregates

Providing &laying cement concrete excluding the cost of centering and shuttering - 1:5:10, 50mm aggregates

Providing &laying cement concrete excluding the cost of centering and shuttering - 1:5:10, 40mm aggregates

Providing and laying second class brick work in foundation and plinth - In cement mortar 1:4

Providing & fixing centering and shuttering (formwork), including strutting, propping etc. and removal of formwork - Foundation and plinth

Page 279: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up

Labour and Material Coefficients (Electrical)- 2013 Page 280

Department of Engineering Services, MoWHS

LB0051 Mason Gd.2 0.339 day LB0077 Labourer 1.87025 day MT6604 Sand 0.2675 cu.m MT6680 Bricks 2nd class 0.407 1000# MT6681 Grey Cement 0.095 tonne CV0170 Coefficient for per sq.m of CV0170

Code Description Quant Units LB0036 Mason Gd.1 0.102 day LB0077 Labourer 0.1512 day MT6604 Sand 0.01541 cu.m MT6681 Grey Cement 0.0036 tonne CV0180 Coefficient for per cu.m of CV0180

Code Description Quant Units LB0077 Labourer (Male) 1.125 day MT6604 Sand 1.07 cu.m MT6681 Grey Cement 0.38 tonne CV0181 Coefficient for per cu.m of CV0181

Code Description Quant Units LB0077 Labourer 1.125 day MT6604 Sand 1.07 cu.m MT6681 Grey Cement 0.25 tonne

Cement mortar 1:4

Providing & laying 12mm cement plaster - In cement mortar 1:6

Cement mortar 1:6

Page 280: MINISTRY OF WORKS AND HUMAN SETTLEMENT · 2014-08-04 · Services under the Ministry of Works and Human Settlement forms an integral part of Bhutan Schedule of Rates. The built-up