minor alterations slackwood elementary...
TRANSCRIPT
DRAWING SYMBOLS
DETAILIDENTIFICATION
BUILDING SECTION
IDENTIFICATION
WALL SECTION
IDENTIFICATION
ELEVATION
MARKS
COLUMN NUMBER
DOOR NUMBER
WINDOW TYPE
REVISION NUMBER
PARTITION TYPE
DATUM or
ELEVATION MARK
CENTERLINE
101
1t
A1.1
#
ROOM TAG
NAMEELEVATION
8A.1
10
CURTAIN WALL or
STOREFRONT TAGCW-1
1
1
1
1
OCC:
ROOM NAME
101150 SF
###
DETAIL NO.
DRAWING NO.
SECTION NO.
DRAWING NO.
SECTION NO.
DRAWING NO.
OPEN HEAD
DETAIL NO.
DRAWING NO.
CLOSED HEAD
SIM/OPP TAG
SIM/OPP TAG
SIM/OPP TAG
EXTERIOR INTERIOR
ROOM NAME
ROOM NUMBER
GROSS SFOCCUPANTS
22A TOILET ACCESSORY TAG
1A1.1
SIM
1A1.1
SIM
A1.11
SIM
1A1.1
SIM
1/A1.1 VIEW REFERENCE
ABBREVIATIONSCJ CONTROL JOINT CMU CONCRETE MASONRY UNITCFMF COLD FORMED METAL FRAMING DN DOWN DWG DRAWING EIFS EXTERIOR INSULATION AND FINISH SYSTEM EL ELEVATION EQ EQUAL EJ EXPANSION JOINT EWC ELECTRIC WATER COOLER FD FLOOR DRAIN FE FIRE EXTINGUISHER (BRACKET MOUNTED) FEC FIRE EXTINGUISHER CABINET FT FOOT or FEET FRTW FIRE RETARDANT TREATED WOOD GALV GALVANIZED GSF GROSS SQUARE FEET GWB GYPSUM WALL BOARD HM HOLLOW METAL HP HIGH POINT LP LOW POINT MAX MAXIMUM MIN MINIMUM MO MASONRY OPENING N/A NOT APPLICABLE NIC NOT IN CONTRACT NSF NET SQUARE FEET OC ON CENTER OD OVERFLOW DRAIN OR OUTSIDE DIAMETER PTD PAINT or PAINTED PTW PRESSURE TREATED WOOD PVC POLYVINYL CHLORIDE RD ROOF DRAIN REINF REINFORCED OR REINFORCING RWC RAIN WATER CONDUCTOR SF SQUARE FEET TOS TOP OF STEEL TYP TYPICAL VIF VERIFY IN FIELD
MATERIAL SYMBOLS
EARTH
POROUS FILL or SUB-SLAB AGGREGATE
CONCRETE
CONCRETE MASONRY UNIT (CMU)
BRICK
GYPSUM WALL AND/OR CEILING BOARD
BATT INSULATION / SOUND ATTENUATION
RIGID INSULATION
STEEL
CONTINUOUS WOOD BLOCKING
WOOD SHIM OR BLOCKING
PLYWOOD
FIRE SAFING
MORTAR NET
SPRAY FOAM INSULATION
STONE
MORTAR / GROUT
SPIEZLE ARCHITECTURAL GROUP, INC
1395 YARDVILLE HAMILTON SQUARE ROAD
SUITE 2A
HAMILTON, NJ 08691
Phone: 609.695.7400 Fax: 609.394.2274
www.spiezle.com
SPIEZLE ARCHITECTURAL GROUP, INC. © 2018 - ALL RIGHTS RESERVED
CODE SUBMISSION:
BID DATE:
FOR THE
DOE STATE PROJECT NUMBER(S):
SPIEZLE COMMISSION NUMBER:
BUSINESS ADMINISTRATOR:
SUPERINTENDENT:
DRAWING
NUMBER:
C:\temp\19K042 - SWES Alter_PCENTRAL_detached_anthonycatana7075.rvt2/20/2020 9:44:08 AM
MINOR ALTERATIONS SLACKWOOD ELEMENTARY SCHOOL
LAWRENCE TOWNSHIP PUBLIC SCHOOLS
MINOR ALTERATIONS
SLACKWOOD ELEMENTARY
SCHOOL
2060 PRINCETON PIKE,
LAWRENCEVILLE, NJ 08648
02-15-2020
19K042
CS.1
2565 PRINCETON PIKE,
LAWRENCEVILLE, NJ 08648
21-2580-100-20-1000
19K042
THOMAS ELDRIDGE
DR. ROSS KASUN
FOR B
ID 2
02
0-0
2-1
5
LIST OF DRAWINGSDWG. NO. TITLEGENERAL
CS.1 COVER
ARCHITECTURAL
A1.1 FLOOR PLANS AND DETAILS
A1.2 REFLECTED CEILING PLAN AND FINISH PLANS
SB SB
FE
FE
.
FE
FE
EXISTINGTOILET21H
STRUCTURAL BEAM ABOVE TO REMAIN
6A1.1
6A1.1
7A1.1
EXISTING SPEAKERTO REMAIN
EXISTING
EMERGENCY
LIGHT
EXISTING SPEAKER
RELOCATED FIRE DEVICES
OCC:
MEDIACENTERB-01
2998 SF150
B-03B-02
B3.2
B3.2
B3.2B3.2
B3
B3
CLOSET
CL-01
B-01
4'-0"
CORRIDOR
B-02
82 SF
CORRIDOR
B-03
111 SF
OCC:
MEDIA
CENTER
B-012998 SF
150
EXISTING IDF
B-4134 SF
STORAGE
ST-01145 SF
CENTER NEW WALLS ON EXISTING COLUMNS (TYP)
2'-0
"
4'-4"
GENERAL DEMOLITION NOTES1. DEMOLITION WORK INCLUDES, BUT IS NOT LIMITED TO THE WORK INDICATED
HEREWITH, AS COORDINATED WITH WORK OF ALL OTHER TRADES. AS INDICATED
ELSEWHERE, AND AS REQUIRED TO ACCOMMODATE CONSTRUCTION. ALL
DEMOLITION REQUIRED SHALL BE INCLUDED IN EACH CONTRACTOR'S BASE BID TO
PERFORM AND COMPLETE CONSTRUCTION, UNLESS OTHERWISE INDICATED. REFER
TO ASBESTOS ABATEMENT REPORT AS WELL AS MECHANICAL, ELECTRICAL AND
PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.
2. ITEMS TO BE RELOCATED OR REINSTALLED SHALL BE AS INDICATED. SPECIAL CARE
SHALL BE TAKEN SO AS NOT TO DAMAGE THESE ITEMS. THE CONTRACTOR SHALL
COORDINATE THE STORAGE OF ALL SALVAGED ITEMS TO BE EITHER RELOCATED OR
REINSTALLED WITH THE OWNER.
3. LOCATIONS AND/OR ELEVATIONS OF EXISTING ITEMS AS SHOWN ON THE DRAWINGS
ARE APPROXIMATE. RESPECTIVE TRADES SHALL FIELD VERIFY ALL LOCATIONS.
4. WHEN A NEW WALL, CEILING, ROOF OR FLOOR ASSEMBLY IS INDICATED WHERE AN
EXISTING WALL, CEILING, ROOF OR FLOOR ASSEMBLY EXISTS, THE EXISTING SHALL BE
COMPLETELY REMOVED, WITH ASSOCIATED UTILITIES REMOVED AND CAPPED BEHIND
THE SURFACES TO REMAIN. ALL DEPRESSIONS, INDENTATIONS, OR PROTRUSIONS
LEFT AFTER THE REMOVAL OF ITEMS WHICH MAY INTERFERE WITH THE
CONSTRUCTION SHALL BE REPAIRED, REPLACED OR REMOVED TO PROVIDE A
SMOOTH TRANSITION BETWEEN NEW AND EXISTING SURFACES.
5. CONTRACTORS SHALL VERIFY ALL CONDITIONS PRIOR TO COMMENCING DEMOLITION.
SHOULD QUESTIONS OR DISCREPANCIES ARISE, THE CONTRACTOR SHALL NOTIFY
THE ARCHITECT, IN WRITING, PRIOR TO PROCEEDING WITH DEMOLITION.
6. WHERE OPENINGS ARE INDICATED TO BE MADE IN EXISTING MASONRY WALLS, OR
EXISTING OPENINGS ARE TO BE INFILLED, THE CONTRACTOR SHALL TOOTH IN NEW
MASONRY CONSTRUCTION TO MATCH ADJACENT COURSING.
7. CONTRACTOR(S) ARE RESPONSIBLE FOR SHORING, BRACING AND UNDERPINNING
RELATED TO THE DEMOLITION, REMOVAL OR CUTTING OF ANY WALL, PARTITION, OR
ANY OTHER LOAD-BEARING OR STRUCTURAL ELEMENT.
8. ALL EXISTING SUSPENDED CEILINGS SHALL BE REMOVED AND REPLACED, INCLUDING
ALL LIGHTING FIXTURES.
9. CEILING MOUNTED FIRE ALARM DEVICES SHALL BE REMOVED AND REINSTALLED IN
NEW SUSPENDED CEILINGS (ON GRID - NOT IN TILES).
10. EXISTING CLOCKS AND SPEAKERS SHALL BE REMOVED AND TURNED OVER TO
OWNER.
11. EXISTING WALLS TO REMAIN SHALL BE PATCHED AND PAINTED.
APPLICABLE CODES (NJ)1. NJ UNIFORM CONSTRUCTION CODE NJAC 5:232. INTERNATIONAL BUILDING CODE, 2015, NEW JERSEY EDITION3. NATIONAL STANDARD PLUMBING CODE, 20154. NATIONAL ELECTRICAL CODE (NFPA 70), 20145. ENERGY SUBCODE, ASHRAE 90.1-20136. INTERNATIONAL MECHANICAL CODE, 20157. INTERNATIONAL FUEL GAS CODE, 20158. REHABILITATION SUBCODE, NJAC 5:23-69. BARRIER FREE SUBCODE, CHAPTER 11 OF IBC/2015 AND ICC/ANSI A117.1-2009.10. ELEVATOR SUBCODE NJAC 5:23-12, ASME
GENERAL NOTES
1. DO NOT SCALE THE DRAWINGS. IF A DIMENSION IS UNCLEAR OR A DISCREPANCY IS FOUND IT SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT.
2. ALL DIMENSIONS SHALL BE FIELD VERIFIED PRIOR TO THE COMMENCEMENT OF WORK. 3. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES, STATUTES, AND
REGULATIONS IN PERFORMANCE OF THE WORK.4. DETAILS AND SECTIONS ON THE DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS AND
ARE INTENDED TO SHOW GENERAL REQUIREMENTS THROUGHOUT. CONDITIONS NOT SPECIFICALLY SHOWN SHALL BE CONSTRUCTED IN A SIMILAR MANNER OR BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION. MODIFICATIONS MAY BE REQUIRED BY THE CONTRACTOR TO ACCOMMODATE FOR MINOR VARIATIONS IN THE WORK.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION AND INSTALLATION OF OWNER SUPPLIED EQUIPMENT AS IDENTIFIED IN THE DRAWINGS AND SPECIFICATIONS, INCLUDING THE RELOCATION OF EXISTING EQUIPMENT.
PLAN LEGEND
EXISTING WALL TO RECEIVE GWB
EXISTING DOOR TO REMAIN
PROPOSED DOOR TO REMAIN
REMOVE AND
RELOCATE ALL EXISTING
EMERGENCY LIGHTS
REMOVE AND
RELOCATE ALL EXISTING
EMERGENCY SPEAKERS
REMOVE AND RELOCATE
ALL EXISTING FIRE SAFETY
DEVICES
EXISTING WALL
(1) LAYER 5/8" GWB BOTH SIDES
EXISTING CEILING TO BE REPLACED BY OWNER
RUBBER BASE
FINISHED FLOOR
EXISTING WALL
(1) LAYER 5/8" GWB
EXISTING CEILING TO BE
REPLACED BY OWNER
RUBBER BASE
FINISHED FLOOR
B3S.G.I
6B
351 SF
S.G.I.
6A
362 SF
S.G.I
5A
368 SF
S.G.I.
5B
356 SF
CENTER NEW WALL ON EXISTING
N
2'-9
"3
'-7"
3" 6"
SEE SCHED.
WIDTH / 2
SEE
SC
HED
.
DO
OR H
EIG
HT
F
SEE SCHED.
WIDTH
SEE
SC
HED
.
DO
OR H
EIG
HT
HM1
DOOR WIDTH
DO
OR H
EIG
HT
2"
2" 2"
J1
H1
DOOR AND FRAME NOTES1. OPENING FORCE OF INTERIOR NON-RATED DOORS SHALL BE NO GREATER THAN 5 LBS.2. OPENING FORCE OF FIRE RATED DOORS SHALL BE NO GREATER THAN 8 LBS.3. ALL EXTERIOR GLAZING IN NON-RATED WALL AND DOOR ASSEMBLIES SHALL BE
MINIMUM 1" INSULATED GLAZING. REFER TO SPECIFICATIONS FOR GLAZING TYPES. 4. PAINT ALL EXPOSED STEEL (COLOR AS SELECTED BY ARCHITECT).5. PROVIDE COMPATIBLE FLASHING MATERIALS BETWEEN DISSIMILAR MATERIALS SUCH
AS STEEL TO ALUMINUM.6. SHIM ASSEMBLIES AS REQUIRED FOR PLUMB AND LEVEL. PROVIDE SEALANT AND
BACKER RODS AT ALL JOINTS BETWEEN WINDOW SYSTEMS, DOOR FRAMES AND OTHER SURROUNDING CONSTRUCTION.
7. ALUMINUM WINDOW AND ENTRANCE FRAMES SHALL NOT BE INSTALLED I DIRECT CONTACT WITH DISSIMILAR BUILDING MATERIALS.
8. THE MINIMUM LATCH SIDE CLEARANCE BETWEEN THE EDGE OF DOOR AND ADJACENT WALL OR OBSTRUCTIONS ON PULL SIDE SHALL BE 1'-6" MINIMUM.
9. THE MINIMUM LATCH SIDE CLEARANCE BETWEEN THE EDGE OF DOOR AND ADJACENT WALL OR OBSTRUCTIONS ON PUSH SIDE SHALL BE 1'-0" MINIMUM.
10. DO NOT APPLY WALL BASE TO HOLLOW METAL OR ALUMINUM FRAMES, UNLESS OTHERWISE NOTED.
11. THE CONTRACTOR SHALL COORDINATE FOR INSTALLATION OF POWER, CONDUIT AND/OR WIRING, ETC. AT OPENINGS SCHEDULED TO RECEIVE DEVICES SUCH AS DOOR CONTACTS. CARD READERS, ELECTRIC LOCKS AND AUTOMATIC DOOR OPENERS.
12. ALL STUD FRAMED WALLS SHALL HAVE FULLY WRAPPED FRAMES13. ALL CMU WALLS OF 12" NOMINAL THICKNESS OR LESS SHALL HAVE FULLY WRAPPED
FRAMES14. ALL CMU WALLS OF NOMINAL THICKNESS GREATER THAN 12" SHALL HAVE FRAMES
WITH 8-3/4" THROAT DIMENSION AND BE LOCATED ON THE CORRIDOR OR SECURE SIDE OF THE OPENING. PROVIDE BULLNOSE CMU ON THE OPPOSITE SIDE.
15. FRAME CONDITIONS AT EXTERIOR OPENINGS MAY VARY. REFER TO SECTION DETAILS FOR MORE SPECIFIC INFORMATION.
ABBREVIATIONS:
HM - HOLLOW METAL
WD - WOOD
AL - ALUMINUM
PARTITION PER PLANS
HOLLOW METAL FRAME
DOOR
SEALANT (TYP.)
5/8
"SEE
FRAM
E TY
PE
HOLLOW METAL FRAME
VARIE
S
1/2
"
1/2
"
5/8" 2"
H1J1
SEALANT (TYP.)
METAL STUDS AT 16" OC (UON)
(1) LAYER 5/8" GWB BOTH SIDES
SEE NOTE 3
SEE NOTE 3
PROVIDE FIRE SAFING AT
ALL FLUTES TO PROVIDE
COMPLETE CLOSURE
BETWEEN PARTITION AND
DECK FOR ALL FIRE RATED
ASSEMBLIES (TYP)
UNFACED BATT INSULATION
FULL DEPTH OF STUD
SCHEDULED CEILING
SCHEDULED BASE
NOTES:
1. PROVIDE TILE BACKER BOARD AT ALL
LOCATIONS TO RECEIVE TILE
2. SEE COMMENTS IN SCHEDULE FOR
ADDITIONAL INFORMATION
3. CONSTRUCT ALL PARTITIONS WITH
SOUND ISOLATION CONSTRUCTION
DETAILS PER REQUIREMENTS OF THE
GYPSUM MANUAL 2012, FIGURE 9,
INCLUDING ACOUSTIC SEALANT AT
PERIMETER OF ALL PARTITIONS. USE FIRE
RATED SEALANTS AT RATED ASSEMBLIES
SEE SCHED.
WIDTH
FINISHED FLOOR
(2) LAYERS TYPE "X" GYP
BOTH SIDES FOR 2 HOUR
RATED ASSEMBLIES
EXISTING
CONFERENCE
ROOM
B-6
EXISTINGCLASSROOM
B-1
EXISTING PTOB-1A
EXISTING CSTSOCIALWORKER
B-1B
EXISTING SGI
B2
EXISTING SGI
B-1D
EXISTING SGI
B-1C
EXISTING
TOILET
21H
EXISTING
STORAGE
B-3
EXISTING IDF
B-4
EXISTING
SPEECH
B-5A
EXISTING
FACULTY
ROOM
B-7
EXISTING
WORK ROOM
B-7A
EXISTING
OFFICE
B-5B
STRUCTURAL BEAM ABOVE TO REMAIN
D1
D1D1D1D1
D1
D1D1
D1
D1
D1 D1
D1
D1
D1
D1
D1
D8
D6
D6
D6
D4 D5D4 D5
D4 D5
D4 D5
D4 D5D4 D5
D4 D5
D4 D5D4 D5
D4 D5
D4
D5
D4
D5
D8
D5D5 D5
STRUCTURAL BEAM ABOVE TO REMAIN
EXISTING SPEAKER
TO REMAIN
EXISTING
EMERGENCY
LIGHT TO REMAIN
EXISTING SPEAKER
TO REMAIN
EXISTING FIRE ALARM DEVICES
REMOVE AND REINSTALL
D8D8
D2
D3
D2
D3
EXISTING FIRE EXTINGUISHER TO REMAIN
EXISTING FIRE DEVICES TO REMAIN EXISTING FIRE DEVICES TO REMAIN
EXISITNG FIRE EXTINGUISHERTO REMAIN
EXISTING SPEAKER TO REMAIN
EXISTING DISCONNECT TO REMAIN
D6
EXISTING
STORAGE
ST-01
D6
SEAL:
SIGNATURE:
CERTIFICATE:
SPIEZLE ARCHITECTURAL GROUP INC.1395 YARDVILLE HAMILTON SQUARE ROAD
SUITE 2AHAMILTON, NJ 08691
Phone: 609-695-7400
PROJECT:
DRAWING TITLE:
DRAWING NUMBER:
COMMISSION NUMBER:
REVISIONS:
FOR
SPIEZLE ARCHITECTURAL GROUP, INC. COPYRIGHT © 2018
THIS
DRAW
ING
IS F
ORM
ATT
ED T
O B
E PR
INTE
D A
T 3
0"x
42
"
1/1
6"=
1'-0
"
0'
8'
16'
32'
48'
1/8
"=1
'-0"
0'
4'
8'
16'
24'
1/4
"=1
'-0"
0'
2'
4'
8'
12'
1/2
"=1
'-0"
0'
1'
2'
4'
6'
3/4
"=1
'-0"
0'
6"
1'
2'
3'
1"=
1'-0
"
0'
6"
1'
2'
3'
1 1
/2"=
1'-0
"
0'
6"
1'
2'
3"=
1'-0
"
0'
3"
6"
1'
CODE REVIEW:
DO NOT SCALE THE DRAWINGS
# REVISION NAME DATE
FOR CODE REVIEW:
FOR BID:
CONSULTANTS:
THOMAS S. PERRINO
SCOTT E. DOWNIE
STEVEN LEONE
STEVEN G. SIEGEL
SPIEZLE ARCHITECTURAL GROUP, INC.
21AI01505400
21AI01674400
21AI01170100
21AI01564200
21AC00063000
AGENCY NUMBER:
C:\temp\19K042 - SWES Alter_PCENTRAL_detached_anthonycatana7075.rvt2/20/2020 9:44:05 AM
MINOR ALTERATIONS
SLACKWOOD
ELEMENTARY SCHOOL
LAWRENCE
TOWNSHIP PUBLIC
SCHOOLS
FLOOR PLANS AND
DETAILS
19K042
A1.1
FOR BID 2020-02-15
2060 PRINCETON PIKE,
LAWRENCEVILLE, NJ 08648
02-15-2020
2565 PRINCETON PIKE,
LAWRENCEVILLE, NJ 08648
21-2580-100-20-1000
1/8" = 1'-0"1BASEMENT FLOOR PLAN
NOT TO SCALE3
EMERGENCY EXIT LIGHTINGNOT TO SCALE
4EXISTING SPEAKERS
NOT TO SCALE5
FIRE EQUIPMENT
KEYPLANAREA OF WORK SHOWN
PLANNORTH
TRUE
NORTH
1 1/2" = 1'-0"6PARTITION TYPE "A"
1 1/2" = 1'-0"7PARTITION TYPE "B"
1/8" = 1'-0"2FIRST FLOOR - SGI CLASSROOMS
1/4" = 1'-0"9DOOR TYPES
1/4" = 1'-0"8FRAME TYPES
DOOR AND FRAME SCHEDULE
MARK LOCATION
DOOR
FRAME TYPE FIRE RATING
HARDWARE
SET REMARKSWIDTH HEIGHT TYPE MATERIAL
B-01 CLOSET 3'-0" 7'-0" F WD HM1 2
B-02 MEDIA CENTER 6'-0" 7'-0" N WD HM1 20 MIN 1
B-03 MEDIA CENTER 6'-0" 7'-0" N WD HM1 20 MIN 1
1" = 1'-0"10FRAME DETAILS
1 1/2" = 1'-0"11PARTITION TYPE "B3"
1/8" = 1'-0"0DEMOLITION BASEMENT PLAN
DEMO KEYNOTE LEGENDKey
Value Keynote Text
D1 REMOVE EXISTING WALL IN ITS ENTIRETY AND ALL RELATED
ITEMS.
D2 REMOVE AND RELOCATE EXISTING EMERGENCY LIGHT.
D3 SALVAGE EXISTING SPEAKER.
D4 REMOVE EXISTING CEILING, LIGHT FIXTURES, AND DEVICES IN
ITS ENTIRETY.
D5 REMOVE EXISTING FLOOR VCT IN ITS ENTIRETY.
D6 REMOVE AND REPLACE EXISTING WOOD PANELING WITH GWB.
D8 REMOVE PORTION OF EXISTING INTERIOR FRAMED WALL
ASSEMBLY AS INDICATED.
PARTITION TYPE 'B' SCHEDULE
TYPE
MARK
STUD
SIZE
FIRE
RATING
TEST
NUMBER
STC
RATING WIDTH COMMENTS
B3 3 5/8" - - 4 7/8"
B3.2 3 5/8" 2 HR UL U414 - 6 1/8"
SD
SD
SD
SDSD
SD
SD SD
SD
FE
FE
.
EXISTING SOFFIT EXISTING SOFFIT
MEDIACENTER
B-01
ACP-28'-4"
ACP-28'-4"
ACP-28'-4"
ACP-28'-4"
ACP-28'-4"
ACP-28'-4"
MEDIACENTER
B-01
CEILING LEGEND
24"x48" ACOUSTIC CEILING PANEL SYSTEM
24"x48" LED LIGHT FIXTURE
NOTES:1. CONTRACTORS SHALL COORDINATE WITH ALL OTHER TRADES PRIOR TO
INSTALLATION OF FIXTURES AND OTHER CEILING DEVICES.2. WHERE CEILING HEIGHTS ARE BELOW WINDOW HEADS THE
CONTRACTOR SHALL PROVIDE FASCIA MOLDING OR TRIM TO MATCH SIZE AND COLOR OF CEILING TRIM.
3. CONTRACTOR TO REMOVE AND REINSTALL ALL EXISTING FIRE ALARM DEVICES. EXISTING SYSTEM WILL REMAIN ACTIVE DURING ALL WORK.
HEIGHT ABOVE FINISHED FLOOR
CEILING TYPEXXX-#12'-10"
EXIT SIGN
SMOKE DETECTOR
EXISTING
TOILET
21H
VCT-1 VCT-1
VCT-1 VCT-1
MEDIA CENTER
B-01
P-1RB-1VCT-1
MEDIA CENTER
B-01
P-1RB-1VCT-1
CORRIDOR
B-02
P-1RB-1VCT-1
CORRIDOR
B-03
P-1RB-1VCT-1
EXISTING IDF
B-4
P-1RB-1EXIST
STORAGE
ST-01
EXISTEXISTEXIST
EXISTING CEILING TO REMAIN
REMOVE AND REPLACE LIGHT FIXTURES
EXISTING CEILING TO REMAIN
REMOVE AND REPLACE LIGHT FIXTURES
S.G.I
6B
P-1RB-1CPT-1
S.G.I.
6A
P-1RB-1CPT-1
S.G.I
5A
P-1RB-1CPT-1
S.G.I.
5B
P-1RB-1CPT-1
CPT-1 CPT-1CPT-1
ACOUSTICAL CEILING PANEL
(TYPE PER PLANS)
WALL ANGLE
WALL ASSEMBLY
HANGER WIRE
12 GA. HANGER WIRE AT MAX. 48" SPACING(2) #12 GAUGE HANGER
WIRES AT 45° WHERE
VERTICAL IS NOT POSSIBLE
MAIN TEE
CROSS TEE
GYPSUM BOARD CEILING
MAIN TEE SPLICE
NOTE:SUSPENSION DETAIL IS SIMILAR FOR BOTH ACOUSTICAL CEILING PANELS AND GYPSUM BOARD CEILINGS
GENERAL FINISH NOTES:
1. NOTES PERTAIN TO AREAS WITHIN THIS SCOPE OF WORK ONLY.
2. CONTACT INTERIOR DESIGNER/ARCHITECT FOR CLARIFICATION IN THE EVENT OF CONTRADICTORY INFORMATION BETWEEN DRAWINGS, LEGEND AND/ OR SPECIFICATIONS OR IF COLOR AND/OR FINISH IS NOT SPECIFIED.
3. REFER TO PLAN FOR GENERAL FINISHES.
4. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING PRODUCT LEAD TIMES TO ENSURE DELIVERY THAT MEETS THE PROJECT SCHEDULE.
5. THE CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL SITE CONDITIONS AND CONFIRM QUANTITIES PRIOR TO ORDERING PRODUCTS. IN THE EVENT OF CONTRADICTORY INFORMATION CONTACT THE INTERIOR DESIGNER/ARCHITECT FOR CLARIFICATION PRIOR TO ORDERING.
6. ALL MATERIALS SHALL BE INSTALLED USING MANUFACTURERS RECOMMENDED INSTALLATION METHODS AND ADHESIVES.
7. WARRANTY INFORMATION AND INSTRUCTIONS OF MAINTENANCE ON ALL FINISH MATERIALS SHALL BE PROVIDED TO THE OWNER AND INCLUDED IN THE CLOSEOUT WARRANTY AND MAINTENANCE MANUAL.
8. THE CONTRACTOR IS RESPONSIBLE FOR SUBMITTING SAMPLES OF ALL FINISHES SPECIFIED TO INTERIOR DESIGNER/ARCHITECT FOR APPROVAL PRIOR TO ORDERING MATERIAL.
9. ALL SUBSTRATE SURFACES ARE TO BE PROPERLY PREPARED TO RECEIVE FINISH MATERIALS. SUBCONTRACTOR IS NOT TO APPLY FINISHES UNTIL SUBSTRATE IS PREPARED PER MANUFACTURES WRITTEN INSTRUCTIONS FOR ALL INSTALLATIONS OR APPLICATIONS.
10. PAINT GRILLS, WALL DIFFUSERS, ELECTRICAL PANELS, WALL MOUNTED BOXES, ACCESS PANELS, ETC., WHICH ARE EXPOSED IN FINISHED SPACES TO MATCH THE SURFACE ON WHICH THEY OCCUR IF THE ITEM IS ON A WALL-COVERED WALL. PROVIDE A CUSTOM PAINT COLOR USED TO MATCH. SUBMIT TO INTERIOR DESIGNER/ARCHITECT FOR APPROVAL.
11. ALL WALL PAINT TO BE EGGSHELL FINISH UON.
12. ALL METAL AND PAINTED TRIM TO BE SEMI-GLOSS ENAMEL FINISH.
13. ALL VINYL/RUBBER BASE TO BE ROLLED GOODS, NOT LINEAR 4’ LENGTHS.
14. FINISHES INDICATED ON "ROOM FINISH TAG" ARE INCLUSIVE OF ALL RESPECTIVE SURFACES IN ROOM (UNLESS OTHERWISE NOTED) WHETHER OR NOT INDICATED ON PLANS OR ELEVATIONS.
FLOOR FINISH NOTES:
1. FLASH PATCH THE FLOOR AT TRANSITION OF ALL MATERIALS, PROVIDE TRANSITION STRIPS AS NECESSARY. SUBMIT TRANSITIONS TO INTERIOR DESIGNER/ARCHITECT FOR APPROVAL. ALL FLOORING TRANSITIONS MUST ADHERE TO THE AMERICANS WITH DISABILITIES ACT.
CPT-1 FINISH TAG
ROOM NAME
A1000
WFBFFF
ROOM FINISH TAG
TYPICAL WALL FINISHBASE FINISH FLOOR FINISH
ROOM NAME
ROOM NUMBER
INTERIOR FINISH LEGEND
P-1 MANUF: BENJAMIN MOORE
COLOR: MATCH EXISTING
FINISH: EGGSHELL
(COLOR FOR WALLS, UNLESS OTHERWISE NOTED)
P-2 MANUF: BENJAMIN MOORE
COLOR: MATCH EXISTING
FINISH: SEMI-GLOSS
(COLOR FOR DOOR FRAMES)
PAINT
VCT-1 MANUF: ARMSTRONG
STYLE: STANDARD TEXTURE IMPERIAL TEXTURE
COLOR: SILK 59234
SIZE: 12"x12"x1/8"
(FIELD COLOR FOR FLOORING)
VINYL COMPOSITION TILE
RB-1 MANUF: JOHNSONITE
STYLE: DURACOVE BASE
COLOR: 40 BLACK
NOTE: 120' COIL
DIMENSIONS: 6" HIGH ROLL GOODS
RUBBER BASE
CPT-1 MANUF: MANNINGTON
STYLE: QUADRANT PRECISION
COLOR: SEACANT 13579
SIZE: 24"x24"x22 OZ.
(FIELD COLOR FOR FLOORING)
CARPET TILE
SEAL:
SIGNATURE:
CERTIFICATE:
SPIEZLE ARCHITECTURAL GROUP INC.1395 YARDVILLE HAMILTON SQUARE ROAD
SUITE 2A
HAMILTON, NJ 08691
Phone: 609-695-7400
PROJECT:
DRAWING TITLE:
DRAWING
NUMBER:
COMMISSION NUMBER:
REVISIONS:
FOR
SPIEZLE ARCHITECTURAL GROUP, INC. COPYRIGHT © 2018
THIS
DRAW
ING
IS F
ORM
ATT
ED T
O B
E PR
INTE
D A
T 3
0"x
42
"
1/1
6"=
1'-0
"
0'
8'
16'
32'
48'
1/8
"=1
'-0"
0'
4'
8'
16'
24'
1/4
"=1
'-0"
0'
2'
4'
8'
12'
1/2
"=1
'-0"
0'
1'
2'
4'
6'
3/4
"=1
'-0"
0'
6"
1'
2'
3'
1"=
1'-0
"
0'
6"
1'
2'
3'
1 1
/2"=
1'-0
"
0'
6"
1'
2'
3"=
1'-0
"
0'
3"
6"
1'
CODE REVIEW:
DO NOT SCALE THE DRAWINGS
# REVISION NAME DATE
FOR CODE REVIEW:
FOR BID:
CONSULTANTS:
THOMAS S. PERRINO
SCOTT E. DOWNIE
STEVEN LEONE
STEVEN G. SIEGEL
SPIEZLE ARCHITECTURAL GROUP, INC.
21AI01505400
21AI01674400
21AI01170100
21AI01564200
21AC00063000
AGENCY NUMBER:
C:\temp\19K042 - SWES Alter_PCENTRAL_detached_anthonycatana7075.rvt2/20/2020 9:44:07 AM
MINOR ALTERATIONS
SLACKWOOD
ELEMENTARY SCHOOL
LAWRENCE
TOWNSHIP PUBLIC
SCHOOLS
REFLECTED CEILING
PLAN AND FINISH
PLANS
19K042
A1.2
FOR BID 2020-02-15
2060 PRINCETON PIKE,
LAWRENCEVILLE, NJ 08648
02-15-2020
2565 PRINCETON PIKE,
LAWRENCEVILLE, NJ 08648
21-2580-100-20-1000
1/8" = 1'-0"1BASEMENT - REFLECTED CEILING PLAN
KEYPLANAREA OF WORK SHOWN
PLAN
NORTH
TRUE
NORTH
1/8" = 1'-0"3BASEMENT - FINISH FLOOR PLAN
1/8" = 1'-0"2FIRST FLOOR - REFLECTED CEILING PLAN
1/8" = 1'-0"4FIRST FLOOR - FINISH FLOOR PLAN - ALTERNATE BID
3" = 1'-0"5EDGE DETAIL AT ACOUSTIC CEILING PANEL
3" = 1'-0"6TYPICAL SUSPENDED CEILING DETAIL
CEILING SCHEDULE
TYPE MARK DESCRIPTION
ACP-2 ACOUSTIC
CEILING PANEL
CEILING
24"x48"