minor alterations slackwood elementary...

3
DRAWING SYMBOLS DETAIL IDENTIFICATION BUILDING SECTION IDENTIFICATION WALL SECTION IDENTIFICATION ELEVATION MARKS COLUMN NUMBER DOOR NUMBER WINDOW TYPE REVISION NUMBER PARTITION TYPE DATUM or ELEVATION MARK CENTERLINE 101 1t A1.1 # ROOM TAG NAME ELEVATION 8A.1 10 CURTAIN WALL or STOREFRONT TAG CW-1 1 1 1 1 OCC: ROOM NAME 101 150 SF ### DETAIL NO. DRAWING NO. SECTION NO. DRAWING NO. SECTION NO. DRAWING NO. OPEN HEAD DETAIL NO. DRAWING NO. CLOSED HEAD SIM/OPP TAG SIM/OPP TAG SIM/OPP TAG EXTERIOR INTERIOR ROOM NAME ROOM NUMBER GROSS SF OCCUPANTS 22A TOILET ACCESSORY TAG 1 A1.1 SIM 1 A1.1 SIM A1.1 1 SIM 1 A1.1 SIM 1/A1.1 VIEW REFERENCE ABBREVIATIONS CJ CONTROL JOINT CMU CONCRETE MASONRY UNIT CFMF COLD FORMED METAL FRAMING DN DOWN DWG DRAWING EIFS EXTERIOR INSULATION AND FINISH SYSTEM EL ELEVATION EQ EQUAL EJ EXPANSION JOINT EWC ELECTRIC WATER COOLER FD FLOOR DRAIN FE FIRE EXTINGUISHER (BRACKET MOUNTED) FEC FIRE EXTINGUISHER CABINET FT FOOT or FEET FRTW FIRE RETARDANT TREATED WOOD GALV GALVANIZED GSF GROSS SQUARE FEET GWB GYPSUM WALL BOARD HM HOLLOW METAL HP HIGH POINT LP LOW POINT MAX MAXIMUM MIN MINIMUM MO MASONRY OPENING N/A NOT APPLICABLE NIC NOT IN CONTRACT NSF NET SQUARE FEET OC ON CENTER OD OVERFLOW DRAIN OR OUTSIDE DIAMETER PTD PAINT or PAINTED PTW PRESSURE TREATED WOOD PVC POLYVINYL CHLORIDE RD ROOF DRAIN REINF REINFORCED OR REINFORCING RWC RAIN WATER CONDUCTOR SF SQUARE FEET TOS TOP OF STEEL TYP TYPICAL VIF VERIFY IN FIELD MATERIAL SYMBOLS EARTH POROUS FILL or SUB-SLAB AGGREGATE CONCRETE CONCRETE MASONRY UNIT (CMU) BRICK GYPSUM WALL AND/OR CEILING BOARD BATT INSULATION / SOUND ATTENUATION RIGID INSULATION STEEL CONTINUOUS WOOD BLOCKING WOOD SHIM OR BLOCKING PLYWOOD FIRE SAFING MORTAR NET SPRAY FOAM INSULATION STONE MORTAR / GROUT SPIEZLE ARCHITECTURAL GROUP, INC 1395 YARDVILLE HAMILTON SQUARE ROAD SUITE 2A HAMILTON, NJ 08691 Phone: 609.695.7400 Fax: 609.394.2274 www.spiezle.com SPIEZLE ARCHITECTURAL GROUP, INC. © 2018 - ALL RIGHTS RESERVED CODE SUBMISSION: BID DATE: FOR THE DOE STATE PROJECT NUMBER(S): SPIEZLE COMMISSION NUMBER: BUSINESS ADMINISTRATOR: SUPERINTENDENT: DRAWING NUMBER: C:\temp\19K042 - SWES Alter_PCENTRAL_detached_anthonycatana7075.rvt 2/20/2020 9:44:08 AM MINOR ALTERATIONS SLACKWOOD ELEMENTARY SCHOOL LAWRENCE TOWNSHIP PUBLIC SCHOOLS MINOR ALTERATIONS SLACKWOOD ELEMENTARY SCHOOL 2060 PRINCETON PIKE, LAWRENCEVILLE, NJ 08648 02-15-2020 19K042 CS.1 2565 PRINCETON PIKE, LAWRENCEVILLE, NJ 08648 21-2580-100-20-1000 19K042 THOMAS ELDRIDGE DR. ROSS KASUN FOR BID 2020-02-15 LIST OF DRAWINGS DWG. NO. TITLE GENERAL CS.1 COVER ARCHITECTURAL A1.1 FLOOR PLANS AND DETAILS A1.2 REFLECTED CEILING PLAN AND FINISH PLANS

Upload: others

Post on 01-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MINOR ALTERATIONS SLACKWOOD ELEMENTARY …jhwilliamsinc.com/wp-content/uploads/2020/02/Lawrence...EMERGENCY LIGHT EXISTING SPEAKER RELOCATED FIRE DEVICES OCC: MEDIA CENTER B-01 2998

DRAWING SYMBOLS

DETAILIDENTIFICATION

BUILDING SECTION

IDENTIFICATION

WALL SECTION

IDENTIFICATION

ELEVATION

MARKS

COLUMN NUMBER

DOOR NUMBER

WINDOW TYPE

REVISION NUMBER

PARTITION TYPE

DATUM or

ELEVATION MARK

CENTERLINE

101

1t

A1.1

#

ROOM TAG

NAMEELEVATION

8A.1

10

CURTAIN WALL or

STOREFRONT TAGCW-1

1

1

1

1

OCC:

ROOM NAME

101150 SF

###

DETAIL NO.

DRAWING NO.

SECTION NO.

DRAWING NO.

SECTION NO.

DRAWING NO.

OPEN HEAD

DETAIL NO.

DRAWING NO.

CLOSED HEAD

SIM/OPP TAG

SIM/OPP TAG

SIM/OPP TAG

EXTERIOR INTERIOR

ROOM NAME

ROOM NUMBER

GROSS SFOCCUPANTS

22A TOILET ACCESSORY TAG

1A1.1

SIM

1A1.1

SIM

A1.11

SIM

1A1.1

SIM

1/A1.1 VIEW REFERENCE

ABBREVIATIONSCJ CONTROL JOINT CMU CONCRETE MASONRY UNITCFMF COLD FORMED METAL FRAMING DN DOWN DWG DRAWING EIFS EXTERIOR INSULATION AND FINISH SYSTEM EL ELEVATION EQ EQUAL EJ EXPANSION JOINT EWC ELECTRIC WATER COOLER FD FLOOR DRAIN FE FIRE EXTINGUISHER (BRACKET MOUNTED) FEC FIRE EXTINGUISHER CABINET FT FOOT or FEET FRTW FIRE RETARDANT TREATED WOOD GALV GALVANIZED GSF GROSS SQUARE FEET GWB GYPSUM WALL BOARD HM HOLLOW METAL HP HIGH POINT LP LOW POINT MAX MAXIMUM MIN MINIMUM MO MASONRY OPENING N/A NOT APPLICABLE NIC NOT IN CONTRACT NSF NET SQUARE FEET OC ON CENTER OD OVERFLOW DRAIN OR OUTSIDE DIAMETER PTD PAINT or PAINTED PTW PRESSURE TREATED WOOD PVC POLYVINYL CHLORIDE RD ROOF DRAIN REINF REINFORCED OR REINFORCING RWC RAIN WATER CONDUCTOR SF SQUARE FEET TOS TOP OF STEEL TYP TYPICAL VIF VERIFY IN FIELD

MATERIAL SYMBOLS

EARTH

POROUS FILL or SUB-SLAB AGGREGATE

CONCRETE

CONCRETE MASONRY UNIT (CMU)

BRICK

GYPSUM WALL AND/OR CEILING BOARD

BATT INSULATION / SOUND ATTENUATION

RIGID INSULATION

STEEL

CONTINUOUS WOOD BLOCKING

WOOD SHIM OR BLOCKING

PLYWOOD

FIRE SAFING

MORTAR NET

SPRAY FOAM INSULATION

STONE

MORTAR / GROUT

SPIEZLE ARCHITECTURAL GROUP, INC

1395 YARDVILLE HAMILTON SQUARE ROAD

SUITE 2A

HAMILTON, NJ 08691

Phone: 609.695.7400 Fax: 609.394.2274

www.spiezle.com

SPIEZLE ARCHITECTURAL GROUP, INC. © 2018 - ALL RIGHTS RESERVED

CODE SUBMISSION:

BID DATE:

FOR THE

DOE STATE PROJECT NUMBER(S):

SPIEZLE COMMISSION NUMBER:

BUSINESS ADMINISTRATOR:

SUPERINTENDENT:

DRAWING

NUMBER:

C:\temp\19K042 - SWES Alter_PCENTRAL_detached_anthonycatana7075.rvt2/20/2020 9:44:08 AM

MINOR ALTERATIONS SLACKWOOD ELEMENTARY SCHOOL

LAWRENCE TOWNSHIP PUBLIC SCHOOLS

MINOR ALTERATIONS

SLACKWOOD ELEMENTARY

SCHOOL

2060 PRINCETON PIKE,

LAWRENCEVILLE, NJ 08648

02-15-2020

19K042

CS.1

2565 PRINCETON PIKE,

LAWRENCEVILLE, NJ 08648

21-2580-100-20-1000

19K042

THOMAS ELDRIDGE

DR. ROSS KASUN

FOR B

ID 2

02

0-0

2-1

5

LIST OF DRAWINGSDWG. NO. TITLEGENERAL

CS.1 COVER

ARCHITECTURAL

A1.1 FLOOR PLANS AND DETAILS

A1.2 REFLECTED CEILING PLAN AND FINISH PLANS

Page 2: MINOR ALTERATIONS SLACKWOOD ELEMENTARY …jhwilliamsinc.com/wp-content/uploads/2020/02/Lawrence...EMERGENCY LIGHT EXISTING SPEAKER RELOCATED FIRE DEVICES OCC: MEDIA CENTER B-01 2998

SB SB

FE

FE

.

FE

FE

EXISTINGTOILET21H

STRUCTURAL BEAM ABOVE TO REMAIN

6A1.1

6A1.1

7A1.1

EXISTING SPEAKERTO REMAIN

EXISTING

EMERGENCY

LIGHT

EXISTING SPEAKER

RELOCATED FIRE DEVICES

OCC:

MEDIACENTERB-01

2998 SF150

B-03B-02

B3.2

B3.2

B3.2B3.2

B3

B3

CLOSET

CL-01

B-01

4'-0"

CORRIDOR

B-02

82 SF

CORRIDOR

B-03

111 SF

OCC:

MEDIA

CENTER

B-012998 SF

150

EXISTING IDF

B-4134 SF

STORAGE

ST-01145 SF

CENTER NEW WALLS ON EXISTING COLUMNS (TYP)

2'-0

"

4'-4"

GENERAL DEMOLITION NOTES1. DEMOLITION WORK INCLUDES, BUT IS NOT LIMITED TO THE WORK INDICATED

HEREWITH, AS COORDINATED WITH WORK OF ALL OTHER TRADES. AS INDICATED

ELSEWHERE, AND AS REQUIRED TO ACCOMMODATE CONSTRUCTION. ALL

DEMOLITION REQUIRED SHALL BE INCLUDED IN EACH CONTRACTOR'S BASE BID TO

PERFORM AND COMPLETE CONSTRUCTION, UNLESS OTHERWISE INDICATED. REFER

TO ASBESTOS ABATEMENT REPORT AS WELL AS MECHANICAL, ELECTRICAL AND

PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION.

2. ITEMS TO BE RELOCATED OR REINSTALLED SHALL BE AS INDICATED. SPECIAL CARE

SHALL BE TAKEN SO AS NOT TO DAMAGE THESE ITEMS. THE CONTRACTOR SHALL

COORDINATE THE STORAGE OF ALL SALVAGED ITEMS TO BE EITHER RELOCATED OR

REINSTALLED WITH THE OWNER.

3. LOCATIONS AND/OR ELEVATIONS OF EXISTING ITEMS AS SHOWN ON THE DRAWINGS

ARE APPROXIMATE. RESPECTIVE TRADES SHALL FIELD VERIFY ALL LOCATIONS.

4. WHEN A NEW WALL, CEILING, ROOF OR FLOOR ASSEMBLY IS INDICATED WHERE AN

EXISTING WALL, CEILING, ROOF OR FLOOR ASSEMBLY EXISTS, THE EXISTING SHALL BE

COMPLETELY REMOVED, WITH ASSOCIATED UTILITIES REMOVED AND CAPPED BEHIND

THE SURFACES TO REMAIN. ALL DEPRESSIONS, INDENTATIONS, OR PROTRUSIONS

LEFT AFTER THE REMOVAL OF ITEMS WHICH MAY INTERFERE WITH THE

CONSTRUCTION SHALL BE REPAIRED, REPLACED OR REMOVED TO PROVIDE A

SMOOTH TRANSITION BETWEEN NEW AND EXISTING SURFACES.

5. CONTRACTORS SHALL VERIFY ALL CONDITIONS PRIOR TO COMMENCING DEMOLITION.

SHOULD QUESTIONS OR DISCREPANCIES ARISE, THE CONTRACTOR SHALL NOTIFY

THE ARCHITECT, IN WRITING, PRIOR TO PROCEEDING WITH DEMOLITION.

6. WHERE OPENINGS ARE INDICATED TO BE MADE IN EXISTING MASONRY WALLS, OR

EXISTING OPENINGS ARE TO BE INFILLED, THE CONTRACTOR SHALL TOOTH IN NEW

MASONRY CONSTRUCTION TO MATCH ADJACENT COURSING.

7. CONTRACTOR(S) ARE RESPONSIBLE FOR SHORING, BRACING AND UNDERPINNING

RELATED TO THE DEMOLITION, REMOVAL OR CUTTING OF ANY WALL, PARTITION, OR

ANY OTHER LOAD-BEARING OR STRUCTURAL ELEMENT.

8. ALL EXISTING SUSPENDED CEILINGS SHALL BE REMOVED AND REPLACED, INCLUDING

ALL LIGHTING FIXTURES.

9. CEILING MOUNTED FIRE ALARM DEVICES SHALL BE REMOVED AND REINSTALLED IN

NEW SUSPENDED CEILINGS (ON GRID - NOT IN TILES).

10. EXISTING CLOCKS AND SPEAKERS SHALL BE REMOVED AND TURNED OVER TO

OWNER.

11. EXISTING WALLS TO REMAIN SHALL BE PATCHED AND PAINTED.

APPLICABLE CODES (NJ)1. NJ UNIFORM CONSTRUCTION CODE NJAC 5:232. INTERNATIONAL BUILDING CODE, 2015, NEW JERSEY EDITION3. NATIONAL STANDARD PLUMBING CODE, 20154. NATIONAL ELECTRICAL CODE (NFPA 70), 20145. ENERGY SUBCODE, ASHRAE 90.1-20136. INTERNATIONAL MECHANICAL CODE, 20157. INTERNATIONAL FUEL GAS CODE, 20158. REHABILITATION SUBCODE, NJAC 5:23-69. BARRIER FREE SUBCODE, CHAPTER 11 OF IBC/2015 AND ICC/ANSI A117.1-2009.10. ELEVATOR SUBCODE NJAC 5:23-12, ASME

GENERAL NOTES

1. DO NOT SCALE THE DRAWINGS. IF A DIMENSION IS UNCLEAR OR A DISCREPANCY IS FOUND IT SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT.

2. ALL DIMENSIONS SHALL BE FIELD VERIFIED PRIOR TO THE COMMENCEMENT OF WORK. 3. CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES, STATUTES, AND

REGULATIONS IN PERFORMANCE OF THE WORK.4. DETAILS AND SECTIONS ON THE DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS AND

ARE INTENDED TO SHOW GENERAL REQUIREMENTS THROUGHOUT. CONDITIONS NOT SPECIFICALLY SHOWN SHALL BE CONSTRUCTED IN A SIMILAR MANNER OR BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION. MODIFICATIONS MAY BE REQUIRED BY THE CONTRACTOR TO ACCOMMODATE FOR MINOR VARIATIONS IN THE WORK.

5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION AND INSTALLATION OF OWNER SUPPLIED EQUIPMENT AS IDENTIFIED IN THE DRAWINGS AND SPECIFICATIONS, INCLUDING THE RELOCATION OF EXISTING EQUIPMENT.

PLAN LEGEND

EXISTING WALL TO RECEIVE GWB

EXISTING DOOR TO REMAIN

PROPOSED DOOR TO REMAIN

REMOVE AND

RELOCATE ALL EXISTING

EMERGENCY LIGHTS

REMOVE AND

RELOCATE ALL EXISTING

EMERGENCY SPEAKERS

REMOVE AND RELOCATE

ALL EXISTING FIRE SAFETY

DEVICES

EXISTING WALL

(1) LAYER 5/8" GWB BOTH SIDES

EXISTING CEILING TO BE REPLACED BY OWNER

RUBBER BASE

FINISHED FLOOR

EXISTING WALL

(1) LAYER 5/8" GWB

EXISTING CEILING TO BE

REPLACED BY OWNER

RUBBER BASE

FINISHED FLOOR

B3S.G.I

6B

351 SF

S.G.I.

6A

362 SF

S.G.I

5A

368 SF

S.G.I.

5B

356 SF

CENTER NEW WALL ON EXISTING

N

2'-9

"3

'-7"

3" 6"

SEE SCHED.

WIDTH / 2

SEE

SC

HED

.

DO

OR H

EIG

HT

F

SEE SCHED.

WIDTH

SEE

SC

HED

.

DO

OR H

EIG

HT

HM1

DOOR WIDTH

DO

OR H

EIG

HT

2"

2" 2"

J1

H1

DOOR AND FRAME NOTES1. OPENING FORCE OF INTERIOR NON-RATED DOORS SHALL BE NO GREATER THAN 5 LBS.2. OPENING FORCE OF FIRE RATED DOORS SHALL BE NO GREATER THAN 8 LBS.3. ALL EXTERIOR GLAZING IN NON-RATED WALL AND DOOR ASSEMBLIES SHALL BE

MINIMUM 1" INSULATED GLAZING. REFER TO SPECIFICATIONS FOR GLAZING TYPES. 4. PAINT ALL EXPOSED STEEL (COLOR AS SELECTED BY ARCHITECT).5. PROVIDE COMPATIBLE FLASHING MATERIALS BETWEEN DISSIMILAR MATERIALS SUCH

AS STEEL TO ALUMINUM.6. SHIM ASSEMBLIES AS REQUIRED FOR PLUMB AND LEVEL. PROVIDE SEALANT AND

BACKER RODS AT ALL JOINTS BETWEEN WINDOW SYSTEMS, DOOR FRAMES AND OTHER SURROUNDING CONSTRUCTION.

7. ALUMINUM WINDOW AND ENTRANCE FRAMES SHALL NOT BE INSTALLED I DIRECT CONTACT WITH DISSIMILAR BUILDING MATERIALS.

8. THE MINIMUM LATCH SIDE CLEARANCE BETWEEN THE EDGE OF DOOR AND ADJACENT WALL OR OBSTRUCTIONS ON PULL SIDE SHALL BE 1'-6" MINIMUM.

9. THE MINIMUM LATCH SIDE CLEARANCE BETWEEN THE EDGE OF DOOR AND ADJACENT WALL OR OBSTRUCTIONS ON PUSH SIDE SHALL BE 1'-0" MINIMUM.

10. DO NOT APPLY WALL BASE TO HOLLOW METAL OR ALUMINUM FRAMES, UNLESS OTHERWISE NOTED.

11. THE CONTRACTOR SHALL COORDINATE FOR INSTALLATION OF POWER, CONDUIT AND/OR WIRING, ETC. AT OPENINGS SCHEDULED TO RECEIVE DEVICES SUCH AS DOOR CONTACTS. CARD READERS, ELECTRIC LOCKS AND AUTOMATIC DOOR OPENERS.

12. ALL STUD FRAMED WALLS SHALL HAVE FULLY WRAPPED FRAMES13. ALL CMU WALLS OF 12" NOMINAL THICKNESS OR LESS SHALL HAVE FULLY WRAPPED

FRAMES14. ALL CMU WALLS OF NOMINAL THICKNESS GREATER THAN 12" SHALL HAVE FRAMES

WITH 8-3/4" THROAT DIMENSION AND BE LOCATED ON THE CORRIDOR OR SECURE SIDE OF THE OPENING. PROVIDE BULLNOSE CMU ON THE OPPOSITE SIDE.

15. FRAME CONDITIONS AT EXTERIOR OPENINGS MAY VARY. REFER TO SECTION DETAILS FOR MORE SPECIFIC INFORMATION.

ABBREVIATIONS:

HM - HOLLOW METAL

WD - WOOD

AL - ALUMINUM

PARTITION PER PLANS

HOLLOW METAL FRAME

DOOR

SEALANT (TYP.)

5/8

"SEE

FRAM

E TY

PE

HOLLOW METAL FRAME

VARIE

S

1/2

"

1/2

"

5/8" 2"

H1J1

SEALANT (TYP.)

METAL STUDS AT 16" OC (UON)

(1) LAYER 5/8" GWB BOTH SIDES

SEE NOTE 3

SEE NOTE 3

PROVIDE FIRE SAFING AT

ALL FLUTES TO PROVIDE

COMPLETE CLOSURE

BETWEEN PARTITION AND

DECK FOR ALL FIRE RATED

ASSEMBLIES (TYP)

UNFACED BATT INSULATION

FULL DEPTH OF STUD

SCHEDULED CEILING

SCHEDULED BASE

NOTES:

1. PROVIDE TILE BACKER BOARD AT ALL

LOCATIONS TO RECEIVE TILE

2. SEE COMMENTS IN SCHEDULE FOR

ADDITIONAL INFORMATION

3. CONSTRUCT ALL PARTITIONS WITH

SOUND ISOLATION CONSTRUCTION

DETAILS PER REQUIREMENTS OF THE

GYPSUM MANUAL 2012, FIGURE 9,

INCLUDING ACOUSTIC SEALANT AT

PERIMETER OF ALL PARTITIONS. USE FIRE

RATED SEALANTS AT RATED ASSEMBLIES

SEE SCHED.

WIDTH

FINISHED FLOOR

(2) LAYERS TYPE "X" GYP

BOTH SIDES FOR 2 HOUR

RATED ASSEMBLIES

EXISTING

CONFERENCE

ROOM

B-6

EXISTINGCLASSROOM

B-1

EXISTING PTOB-1A

EXISTING CSTSOCIALWORKER

B-1B

EXISTING SGI

B2

EXISTING SGI

B-1D

EXISTING SGI

B-1C

EXISTING

TOILET

21H

EXISTING

STORAGE

B-3

EXISTING IDF

B-4

EXISTING

SPEECH

B-5A

EXISTING

FACULTY

ROOM

B-7

EXISTING

WORK ROOM

B-7A

EXISTING

OFFICE

B-5B

STRUCTURAL BEAM ABOVE TO REMAIN

D1

D1D1D1D1

D1

D1D1

D1

D1

D1 D1

D1

D1

D1

D1

D1

D8

D6

D6

D6

D4 D5D4 D5

D4 D5

D4 D5

D4 D5D4 D5

D4 D5

D4 D5D4 D5

D4 D5

D4

D5

D4

D5

D8

D5D5 D5

STRUCTURAL BEAM ABOVE TO REMAIN

EXISTING SPEAKER

TO REMAIN

EXISTING

EMERGENCY

LIGHT TO REMAIN

EXISTING SPEAKER

TO REMAIN

EXISTING FIRE ALARM DEVICES

REMOVE AND REINSTALL

D8D8

D2

D3

D2

D3

EXISTING FIRE EXTINGUISHER TO REMAIN

EXISTING FIRE DEVICES TO REMAIN EXISTING FIRE DEVICES TO REMAIN

EXISITNG FIRE EXTINGUISHERTO REMAIN

EXISTING SPEAKER TO REMAIN

EXISTING DISCONNECT TO REMAIN

D6

EXISTING

STORAGE

ST-01

D6

SEAL:

SIGNATURE:

CERTIFICATE:

SPIEZLE ARCHITECTURAL GROUP INC.1395 YARDVILLE HAMILTON SQUARE ROAD

SUITE 2AHAMILTON, NJ 08691

Phone: 609-695-7400

PROJECT:

DRAWING TITLE:

DRAWING NUMBER:

COMMISSION NUMBER:

REVISIONS:

FOR

SPIEZLE ARCHITECTURAL GROUP, INC. COPYRIGHT © 2018

THIS

DRAW

ING

IS F

ORM

ATT

ED T

O B

E PR

INTE

D A

T 3

0"x

42

"

1/1

6"=

1'-0

"

0'

8'

16'

32'

48'

1/8

"=1

'-0"

0'

4'

8'

16'

24'

1/4

"=1

'-0"

0'

2'

4'

8'

12'

1/2

"=1

'-0"

0'

1'

2'

4'

6'

3/4

"=1

'-0"

0'

6"

1'

2'

3'

1"=

1'-0

"

0'

6"

1'

2'

3'

1 1

/2"=

1'-0

"

0'

6"

1'

2'

3"=

1'-0

"

0'

3"

6"

1'

CODE REVIEW:

DO NOT SCALE THE DRAWINGS

# REVISION NAME DATE

FOR CODE REVIEW:

FOR BID:

CONSULTANTS:

THOMAS S. PERRINO

SCOTT E. DOWNIE

STEVEN LEONE

STEVEN G. SIEGEL

SPIEZLE ARCHITECTURAL GROUP, INC.

21AI01505400

21AI01674400

21AI01170100

21AI01564200

21AC00063000

AGENCY NUMBER:

C:\temp\19K042 - SWES Alter_PCENTRAL_detached_anthonycatana7075.rvt2/20/2020 9:44:05 AM

MINOR ALTERATIONS

SLACKWOOD

ELEMENTARY SCHOOL

LAWRENCE

TOWNSHIP PUBLIC

SCHOOLS

FLOOR PLANS AND

DETAILS

19K042

A1.1

FOR BID 2020-02-15

2060 PRINCETON PIKE,

LAWRENCEVILLE, NJ 08648

02-15-2020

2565 PRINCETON PIKE,

LAWRENCEVILLE, NJ 08648

21-2580-100-20-1000

1/8" = 1'-0"1BASEMENT FLOOR PLAN

NOT TO SCALE3

EMERGENCY EXIT LIGHTINGNOT TO SCALE

4EXISTING SPEAKERS

NOT TO SCALE5

FIRE EQUIPMENT

KEYPLANAREA OF WORK SHOWN

PLANNORTH

TRUE

NORTH

1 1/2" = 1'-0"6PARTITION TYPE "A"

1 1/2" = 1'-0"7PARTITION TYPE "B"

1/8" = 1'-0"2FIRST FLOOR - SGI CLASSROOMS

1/4" = 1'-0"9DOOR TYPES

1/4" = 1'-0"8FRAME TYPES

DOOR AND FRAME SCHEDULE

MARK LOCATION

DOOR

FRAME TYPE FIRE RATING

HARDWARE

SET REMARKSWIDTH HEIGHT TYPE MATERIAL

B-01 CLOSET 3'-0" 7'-0" F WD HM1 2

B-02 MEDIA CENTER 6'-0" 7'-0" N WD HM1 20 MIN 1

B-03 MEDIA CENTER 6'-0" 7'-0" N WD HM1 20 MIN 1

1" = 1'-0"10FRAME DETAILS

1 1/2" = 1'-0"11PARTITION TYPE "B3"

1/8" = 1'-0"0DEMOLITION BASEMENT PLAN

DEMO KEYNOTE LEGENDKey

Value Keynote Text

D1 REMOVE EXISTING WALL IN ITS ENTIRETY AND ALL RELATED

ITEMS.

D2 REMOVE AND RELOCATE EXISTING EMERGENCY LIGHT.

D3 SALVAGE EXISTING SPEAKER.

D4 REMOVE EXISTING CEILING, LIGHT FIXTURES, AND DEVICES IN

ITS ENTIRETY.

D5 REMOVE EXISTING FLOOR VCT IN ITS ENTIRETY.

D6 REMOVE AND REPLACE EXISTING WOOD PANELING WITH GWB.

D8 REMOVE PORTION OF EXISTING INTERIOR FRAMED WALL

ASSEMBLY AS INDICATED.

PARTITION TYPE 'B' SCHEDULE

TYPE

MARK

STUD

SIZE

FIRE

RATING

TEST

NUMBER

STC

RATING WIDTH COMMENTS

B3 3 5/8" - - 4 7/8"

B3.2 3 5/8" 2 HR UL U414 - 6 1/8"

Page 3: MINOR ALTERATIONS SLACKWOOD ELEMENTARY …jhwilliamsinc.com/wp-content/uploads/2020/02/Lawrence...EMERGENCY LIGHT EXISTING SPEAKER RELOCATED FIRE DEVICES OCC: MEDIA CENTER B-01 2998

SD

SD

SD

SDSD

SD

SD SD

SD

FE

FE

.

EXISTING SOFFIT EXISTING SOFFIT

MEDIACENTER

B-01

ACP-28'-4"

ACP-28'-4"

ACP-28'-4"

ACP-28'-4"

ACP-28'-4"

ACP-28'-4"

MEDIACENTER

B-01

CEILING LEGEND

24"x48" ACOUSTIC CEILING PANEL SYSTEM

24"x48" LED LIGHT FIXTURE

NOTES:1. CONTRACTORS SHALL COORDINATE WITH ALL OTHER TRADES PRIOR TO

INSTALLATION OF FIXTURES AND OTHER CEILING DEVICES.2. WHERE CEILING HEIGHTS ARE BELOW WINDOW HEADS THE

CONTRACTOR SHALL PROVIDE FASCIA MOLDING OR TRIM TO MATCH SIZE AND COLOR OF CEILING TRIM.

3. CONTRACTOR TO REMOVE AND REINSTALL ALL EXISTING FIRE ALARM DEVICES. EXISTING SYSTEM WILL REMAIN ACTIVE DURING ALL WORK.

HEIGHT ABOVE FINISHED FLOOR

CEILING TYPEXXX-#12'-10"

EXIT SIGN

SMOKE DETECTOR

EXISTING

TOILET

21H

VCT-1 VCT-1

VCT-1 VCT-1

MEDIA CENTER

B-01

P-1RB-1VCT-1

MEDIA CENTER

B-01

P-1RB-1VCT-1

CORRIDOR

B-02

P-1RB-1VCT-1

CORRIDOR

B-03

P-1RB-1VCT-1

EXISTING IDF

B-4

P-1RB-1EXIST

STORAGE

ST-01

EXISTEXISTEXIST

EXISTING CEILING TO REMAIN

REMOVE AND REPLACE LIGHT FIXTURES

EXISTING CEILING TO REMAIN

REMOVE AND REPLACE LIGHT FIXTURES

S.G.I

6B

P-1RB-1CPT-1

S.G.I.

6A

P-1RB-1CPT-1

S.G.I

5A

P-1RB-1CPT-1

S.G.I.

5B

P-1RB-1CPT-1

CPT-1 CPT-1CPT-1

ACOUSTICAL CEILING PANEL

(TYPE PER PLANS)

WALL ANGLE

WALL ASSEMBLY

HANGER WIRE

12 GA. HANGER WIRE AT MAX. 48" SPACING(2) #12 GAUGE HANGER

WIRES AT 45° WHERE

VERTICAL IS NOT POSSIBLE

MAIN TEE

CROSS TEE

GYPSUM BOARD CEILING

MAIN TEE SPLICE

NOTE:SUSPENSION DETAIL IS SIMILAR FOR BOTH ACOUSTICAL CEILING PANELS AND GYPSUM BOARD CEILINGS

GENERAL FINISH NOTES:

1. NOTES PERTAIN TO AREAS WITHIN THIS SCOPE OF WORK ONLY.

2. CONTACT INTERIOR DESIGNER/ARCHITECT FOR CLARIFICATION IN THE EVENT OF CONTRADICTORY INFORMATION BETWEEN DRAWINGS, LEGEND AND/ OR SPECIFICATIONS OR IF COLOR AND/OR FINISH IS NOT SPECIFIED.

3. REFER TO PLAN FOR GENERAL FINISHES.

4. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING PRODUCT LEAD TIMES TO ENSURE DELIVERY THAT MEETS THE PROJECT SCHEDULE.

5. THE CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL SITE CONDITIONS AND CONFIRM QUANTITIES PRIOR TO ORDERING PRODUCTS. IN THE EVENT OF CONTRADICTORY INFORMATION CONTACT THE INTERIOR DESIGNER/ARCHITECT FOR CLARIFICATION PRIOR TO ORDERING.

6. ALL MATERIALS SHALL BE INSTALLED USING MANUFACTURERS RECOMMENDED INSTALLATION METHODS AND ADHESIVES.

7. WARRANTY INFORMATION AND INSTRUCTIONS OF MAINTENANCE ON ALL FINISH MATERIALS SHALL BE PROVIDED TO THE OWNER AND INCLUDED IN THE CLOSEOUT WARRANTY AND MAINTENANCE MANUAL.

8. THE CONTRACTOR IS RESPONSIBLE FOR SUBMITTING SAMPLES OF ALL FINISHES SPECIFIED TO INTERIOR DESIGNER/ARCHITECT FOR APPROVAL PRIOR TO ORDERING MATERIAL.

9. ALL SUBSTRATE SURFACES ARE TO BE PROPERLY PREPARED TO RECEIVE FINISH MATERIALS. SUBCONTRACTOR IS NOT TO APPLY FINISHES UNTIL SUBSTRATE IS PREPARED PER MANUFACTURES WRITTEN INSTRUCTIONS FOR ALL INSTALLATIONS OR APPLICATIONS.

10. PAINT GRILLS, WALL DIFFUSERS, ELECTRICAL PANELS, WALL MOUNTED BOXES, ACCESS PANELS, ETC., WHICH ARE EXPOSED IN FINISHED SPACES TO MATCH THE SURFACE ON WHICH THEY OCCUR IF THE ITEM IS ON A WALL-COVERED WALL. PROVIDE A CUSTOM PAINT COLOR USED TO MATCH. SUBMIT TO INTERIOR DESIGNER/ARCHITECT FOR APPROVAL.

11. ALL WALL PAINT TO BE EGGSHELL FINISH UON.

12. ALL METAL AND PAINTED TRIM TO BE SEMI-GLOSS ENAMEL FINISH.

13. ALL VINYL/RUBBER BASE TO BE ROLLED GOODS, NOT LINEAR 4’ LENGTHS.

14. FINISHES INDICATED ON "ROOM FINISH TAG" ARE INCLUSIVE OF ALL RESPECTIVE SURFACES IN ROOM (UNLESS OTHERWISE NOTED) WHETHER OR NOT INDICATED ON PLANS OR ELEVATIONS.

FLOOR FINISH NOTES:

1. FLASH PATCH THE FLOOR AT TRANSITION OF ALL MATERIALS, PROVIDE TRANSITION STRIPS AS NECESSARY. SUBMIT TRANSITIONS TO INTERIOR DESIGNER/ARCHITECT FOR APPROVAL. ALL FLOORING TRANSITIONS MUST ADHERE TO THE AMERICANS WITH DISABILITIES ACT.

CPT-1 FINISH TAG

ROOM NAME

A1000

WFBFFF

ROOM FINISH TAG

TYPICAL WALL FINISHBASE FINISH FLOOR FINISH

ROOM NAME

ROOM NUMBER

INTERIOR FINISH LEGEND

P-1 MANUF: BENJAMIN MOORE

COLOR: MATCH EXISTING

FINISH: EGGSHELL

(COLOR FOR WALLS, UNLESS OTHERWISE NOTED)

P-2 MANUF: BENJAMIN MOORE

COLOR: MATCH EXISTING

FINISH: SEMI-GLOSS

(COLOR FOR DOOR FRAMES)

PAINT

VCT-1 MANUF: ARMSTRONG

STYLE: STANDARD TEXTURE IMPERIAL TEXTURE

COLOR: SILK 59234

SIZE: 12"x12"x1/8"

(FIELD COLOR FOR FLOORING)

VINYL COMPOSITION TILE

RB-1 MANUF: JOHNSONITE

STYLE: DURACOVE BASE

COLOR: 40 BLACK

NOTE: 120' COIL

DIMENSIONS: 6" HIGH ROLL GOODS

RUBBER BASE

CPT-1 MANUF: MANNINGTON

STYLE: QUADRANT PRECISION

COLOR: SEACANT 13579

SIZE: 24"x24"x22 OZ.

(FIELD COLOR FOR FLOORING)

CARPET TILE

SEAL:

SIGNATURE:

CERTIFICATE:

SPIEZLE ARCHITECTURAL GROUP INC.1395 YARDVILLE HAMILTON SQUARE ROAD

SUITE 2A

HAMILTON, NJ 08691

Phone: 609-695-7400

PROJECT:

DRAWING TITLE:

DRAWING

NUMBER:

COMMISSION NUMBER:

REVISIONS:

FOR

SPIEZLE ARCHITECTURAL GROUP, INC. COPYRIGHT © 2018

THIS

DRAW

ING

IS F

ORM

ATT

ED T

O B

E PR

INTE

D A

T 3

0"x

42

"

1/1

6"=

1'-0

"

0'

8'

16'

32'

48'

1/8

"=1

'-0"

0'

4'

8'

16'

24'

1/4

"=1

'-0"

0'

2'

4'

8'

12'

1/2

"=1

'-0"

0'

1'

2'

4'

6'

3/4

"=1

'-0"

0'

6"

1'

2'

3'

1"=

1'-0

"

0'

6"

1'

2'

3'

1 1

/2"=

1'-0

"

0'

6"

1'

2'

3"=

1'-0

"

0'

3"

6"

1'

CODE REVIEW:

DO NOT SCALE THE DRAWINGS

# REVISION NAME DATE

FOR CODE REVIEW:

FOR BID:

CONSULTANTS:

THOMAS S. PERRINO

SCOTT E. DOWNIE

STEVEN LEONE

STEVEN G. SIEGEL

SPIEZLE ARCHITECTURAL GROUP, INC.

21AI01505400

21AI01674400

21AI01170100

21AI01564200

21AC00063000

AGENCY NUMBER:

C:\temp\19K042 - SWES Alter_PCENTRAL_detached_anthonycatana7075.rvt2/20/2020 9:44:07 AM

MINOR ALTERATIONS

SLACKWOOD

ELEMENTARY SCHOOL

LAWRENCE

TOWNSHIP PUBLIC

SCHOOLS

REFLECTED CEILING

PLAN AND FINISH

PLANS

19K042

A1.2

FOR BID 2020-02-15

2060 PRINCETON PIKE,

LAWRENCEVILLE, NJ 08648

02-15-2020

2565 PRINCETON PIKE,

LAWRENCEVILLE, NJ 08648

21-2580-100-20-1000

1/8" = 1'-0"1BASEMENT - REFLECTED CEILING PLAN

KEYPLANAREA OF WORK SHOWN

PLAN

NORTH

TRUE

NORTH

1/8" = 1'-0"3BASEMENT - FINISH FLOOR PLAN

1/8" = 1'-0"2FIRST FLOOR - REFLECTED CEILING PLAN

1/8" = 1'-0"4FIRST FLOOR - FINISH FLOOR PLAN - ALTERNATE BID

3" = 1'-0"5EDGE DETAIL AT ACOUSTIC CEILING PANEL

3" = 1'-0"6TYPICAL SUSPENDED CEILING DETAIL

CEILING SCHEDULE

TYPE MARK DESCRIPTION

ACP-2 ACOUSTIC

CEILING PANEL

CEILING

24"x48"