mission valley power energy efficient home program deemed savings analysis
DESCRIPTION
Mission Valley Power Energy Efficient Home Program Deemed Savings Analysis. August 5, 2008. Background. Mission Valley Power (MVP) request that the RTF review its specifications for a new residential construction program to establish a deemed savings value and cost-effectiveness - PowerPoint PPT PresentationTRANSCRIPT
1
Mission Valley Power Energy Efficient Home ProgramDeemed Savings Analysis
August 5, 2008
2
Background
• Mission Valley Power (MVP) request that the RTF review its specifications for a new residential construction program to establish a deemed savings value and cost-effectiveness
• MVP also provided an analysis of the potential savings from requiring R-10 full under slab insulation with an R-5 slab edge thermal break for RTF review and potential adoption as a deemed measure.
3
MVP Deemed Savings Analysis – R-10 Full Slab w/R-5 Thermal Break
• Used WattSUN model w/Kalispell Weather• Assumed MT Code as baseline, then modeled full slab
insulation w/ thermal break (UA 549) vs UA 518)– Wall (Above Grade) = R-19– Wall (Below Grade) = R-11 (0.054 base/0.056 w/full slab)– Attic = R-38– Glazing = U- 0.35– Door = U-0.19– On grade slab – R-0 (F-0.73) & R-10 w/R-5 TB (F-0.36)– Below grade slab = R-0 (F-0.56) & R-10 w/R-5 TB (F-0.42)
• Savings = 1.5 kWh/sq.ft. of slab
4
MVP Deemed Savings Analysis – Energy Efficient Home
• Used WattSUN model w/Kalispell Weather• Assumed MT Code as baseline, compared
to– EStar Home BOP 2 – MVP Home specifications
• Results– EStar Home BOP 2 = 32% savings– MVP Home = 36% savings
Savings Input Assumptions – Crawlspace Home, Zonal Electric
Component MT Code EStar BOP 2
MVP Home V. Crawl
MVP Home S. Crawl
MVP Home Slab only
MVP Home Basement
Floor R-21 R-30 N/A R-38 N/A R-38
Slab on grade R-13 per. N/A N/A N/A R-10 full R-10 full
Glazing U-0.35 U-0.30 U-0.32 U-0.32 U-0.35 U-0.32
Doors U-0.19 U-0.19 U-0.16 U-0.16 U-0.19 U-0.16
Wall (Above grade) R-21 Std R-23 Std R-26 Adv R-26 Adv R-21 Std R-26 Adv
Wall (Below grade)* R-11 Std R-23 Std N/A R-21 Adv R-11 Std R-21 Adv
Attic R-38 R-38 R-49 Adv R-49 Adv R-38 R-49 Adv
Infiltration 0.35 ach 0.20 ach w/HRV
0.30 ach w/o HRV
0.30 ach w/o HRV
0.35 ach 0.30 ach w/o HRV
Overall UA 543 474 387 483 502 461
*MT Code does not require below grade walls to be insulated until “finished.” EStar & MVP require R-21 insulation at time of construction.
6
Issues
• Specifications – Perimeter insulation permitted in lieu of R-38 under floor (may not
produce equivalent energy savings)– Assumed duct leakage rate for forced-air systems not specified– MVP requires 25% of sockets w/EStar Lighting, EStar requires
50% - Net impact on savings not quantified in analysis– No HRV required, even though savings are claimed for reduce
infiltration
• Quality Assurance– Performance testing of ducts is not required – 0.30 ach Air tightness verified by random testing (same as EStar,
but EStar assumes 0.35 ach)
7
Results of Review – R10 Full Slab
• SEEM Model used to estimate use and savings– Full R-10 Slab w/R-5 Thermal Break
• WattSun Savings = 1.5 kWh/sq.ft. slab (zonal electric)
• SEEM Savings = 1.0 kWh/sq.ft. slab (zonal electric)
• No Cost Data Yet to Determine Cost-Effectiveness
8
Results of Review – MVP Home Savings
Case MT Code
EStar BOP 2
MVP Home V. Crawl
MVP Home S. Crawl
MVP Home Slab only
MVP Home Basement
Annual Use (kWh)
18710 13717 13787 17895 18268 15844
Savings over Code
- 4994 4923 816 443 2866