mitsubishi electric 2011 air conditioning product catalogue

161
Air Conditioning Commercial Heating Domestic Heating Photovoltaics World of Making a Difference The Renewable Solutions Provider 2011 Air Conditioning Product Catalogue Features Key

Upload: luke-hopkins

Post on 26-Mar-2016

363 views

Category:

Documents


5 download

DESCRIPTION

Mitsubishi Electric 2011 Air Conditioning Product Catalogue

TRANSCRIPT

Page 1: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Corporate SalesTel: 0870 3000 070

Fax: 0870 3000 080

ScotlandTel: 01506 444960

Fax: 01506 444961

ManchesterTel: 0161 866 6060

Fax: 0161 866 6081

BirminghamTel: 0121 741 2800

Fax: 0121 741 2801

BristolTel: 01454 202050

Fax: 01454 202900

IrelandTel: +353 (0)1 419 8800

Fax: +353 (0)1 419 8890

email: [email protected]

LeedsTel: 0870 3300 347

Fax: 0870 3300 348

London Central RegionTel: 0207 928 6810

Fax: 0207 928 6569

London North RegionTel: 01707 282480

Fax: 01707 282481

Sales Offices:

London South RegionTel: 01689 881030

Fax: 01689 881031

20

11

Air C

ond

itionin

g P

rod

uct C

ata

log

ue

After Sales Service: 0161 866 6089

email: [email protected]

web: www.mitsubishielectric.co.uk/aircon

UNITED KINGDOM Mitsubishi Electric Europe Living Environmental Systems Division

Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England

General Enquiries Telephone: 01707 282880 Fax: 01707 278881

IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland

Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531)

Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2011. Mitsubishi and Mitsubishi Electric

are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the

equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly

developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general

particulars and shall not form part of any contract. All goods are supplied subject to the Company’s General Conditions of Sale, a copy of

which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.

Printed in November 2010 SAP No. 237005

Designed by Square Bear Limited 01604 899099. Square Bear Limited are committed to using FSC certified paper and printers,

wherever possible. The sealant process used on this catalogue is environmentally friendly, recyclable and biodegradable.

Air Conditioning Commercial Heating

Domestic Heating Photovoltaics

Wor ld ofMaking a

Dif ference

The Renewable Solutions Provider

2011 Air ConditioningProduct Catalogue

Features Key

Page 2: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Mitsubishi Electric Partner Programme

Open to all contractors - large or small - the Mitsubishi Electric Partner Programme offers contractors

a totally new and unique set of benefits. There are two categories within the programme - Accredited

Installer and Business Solutions Partner. These levels are a straight-forward reflection of the Partner’s

stage of growth. All customers signing up to the programme standards are committing to continued

training and professional development.

For more information please contact your local sales office

Mitsubishi Electric Training Options

Mitsubishi Electric has four state-of-the-art training suites based at different

locations around the country for your convenience. Providing training for

all levels of expertise, our courses are taught by experienced engineers,

with a wealth of knowledge and are all CPD accredited.

For bookings please telephone 0161 866 6089

Many of our systems have an energy label of A. These systems meet the criteria of the

Energy Technology List and hence could qualify for 100% first year enhanced capital allowances

(whole system cost and ‘reasonable’ cost of installation). For further information please

go to www.eca.gov.uk

Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.

Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.

UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB.

UK Conditions: Winter ; indoor 21˚C DB; outdoor -1˚C WB.

Note: The fuse rating is only a typical value, it is the responsibility of a

qualified electrician/electrical engineer to select the correct cable size

and fuse rating based on current regulation and site specific conditions.

the name Mitsubishi is

synonymous with excellence

Known the world over, Mitsubishi is a trusted global leader

associated with a variety of products and services. Founded

in 1921, Mitsubishi Electric quickly rose to the forefront of the

air conditioning industry - a position we still enjoy today.

Unsurpassed air conditioning from Mitsubishi ElectricAir conditioning is an ideal way of controlling the internal environment of any building, large or

small. It does not only provide cooling when required, but also heating and often hot water can

be supplied from the same system. Providing heating and hot water as part of an integrated

air conditioning system is far more efficient than traditional heating methods such as gas and as a result

reduced running costs and emissions can be realised. More and more people are experiencing the

benefits of comfortable working, living and leisure environments made possible with air conditioning.

As market leaders, we pride ourselves in providing high performance, competitive systems with

low running costs and emissions.

Environmental AwarenessMitsubishi Electric boasts an explicit commitment to sustainable business practices such as energy

and resource efficiency, minimising ecological impacts and reducing greenhouse gas emissions. All of

our factories and UK operations are ISO14001 registered, the international standard that ensures

that we are fully aware of the environmental impact of all our processes and ensures we have

procedures in place to reduce them. However, we have gone far further than any accepted

minimum standards. Our ‘Environmental Vision 2021’ provides a vision for a lower emission future

that influences all our policy decisions. Our Green Gateway Initiative takes this vision even further

as it looks to install behavioural change in our own operations and our wider sphere of influence

with contractors, consultants and end users. It looks to highlight the advantages and opportunities

provided, by ensuring all of our activities are undertaken with consideration to the environment.

We are also proud to be a partner within Sustainable Energy Europe, whose stated aim is to raise

awareness of energy use in Europe.

The Forest Stewardship Council (FSC) is an international network promoting responsible

management of the world's forest. The paper this catalogue is printed on supports the

development of responsible forest management worldwide. The wood comes from FSC

certified, well managed forests, company controlled sources and/or recycled material.

www.green-gateway.co.uk

www.sustenergy.org

www.mitsubishielectric.com/eco

Nano Platinum filter - incorporates nanometre sized platinum-ceramic particles that generate stable antibacterial and deodourising effects

Low unit height - minimal intrusioninto occupied space

Double thermostat function - control the temp via a sensorin the controller or the unit (wired remote controllers only)

I-Save - Recalls the preferred (preset) temperaturevia a single button

Catechin filter - improves air quality and preventsthe spread of bacteria and viruses within the room

Air Cleaning filter - catches dust particles andcontaminates, helping to keep the air fresh

Anti-Allergy Enzyme filter - artificial enzymecatalyst on the filament catches allergens

Swing Vane Mode

Auto Vane Shutter - when unit is switched offthe vane automatically closes

Wide Swing - distributes air laterally by up to 150º

Long Airflow Mode - particularly suitable foruse in long, narrow spaces

Infra-red remote controller

Optimised rotary or scroll compressor

Econo Cool - allows set temperature to be raised by 2ºCwithout any loss of comfort and a 20% gain in energy efficiency

Inverter control - adjusts performance to economically matchthe demand for heating or cooling

Auto-Restart

Quiet operation

72 different airflow patterns - 2, 3 or 4 way discharge

High ceiling compatibility through wide flow air outlets

Auto-Changeover

Hot Start - draught prevention

Factory charged refrigerant up to 30m

Standard filter

Optional high efficiency filter

Plasma Duo filter system

Quick clean design

Drain lift pump as standard

Optional drain lift pump

High external static pressure

Optional high static fan motor

Fresh air knockout

Branch duct knockout

Ceiling soiling prevention

Replace Technology available

Refrigerant volume check function

I-See Sensor

Duty Standby Operation

Page 3: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Contents

Page 1

The Mitsubishi Electric Air ConditioningProduct Catalogue The new 2011 catalogue offers you moreinformation than ever before. That’s because theMitsubishi Electric air conditioning range containsmany new models, plus a fully comprehensiveselection of control options to choose from.

In addition to increasing the range, we’ve also triedto help you find what you need more quickly andefficiently. We hope you will find it an interestingand informative read.

If there is anything not covered in the catalogueand you want to know more, simply contact your Mitsubishi Electric supplier who will be delighted to help you. Alternatively, you can visit our websiteat www.mitsubishielectric.co.uk/aircon for further information.

Page 13 - 62

Page 63 - 131

Page 133 - 243

Page 245 - 264

Page 265 - 307

Page 4: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Air Conditioning Commercial Heating

Domestic Heating Photovoltaics

M Ser ies &Mr Sl im Split-System Air Conditioning

Page 5: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Inverter technology saves energy for two main reasons:

1. The compressor varies its speed to match the cooling or heating load and therefore consumes only the power necessary to match the exact requirement of the room.

2. When an inverter driven air conditioner is operating at partial load, the energy efficiency of the system is significantly higher than at full load. In a typical application, partial load conditions prevail for more than 90% of operation time. A fixed speed system can only operate at 100% capacity and cannot match the annual efficiencies of an inverter system.

The entire R410A M Series and Mr Slim ranges are inverter controlled

The adoption of this technology as standard by Mitsubishi Electric shows our commitment to both increasing your savings, as well as protecting the global environment.

Page 5

Mitsubishi ElectricSplit-Systems

M Series and Mr Slim

Mitsubishi Electric’s M Series and Mr Slim range of split-systems havebenefited from massive investment year on year, the overall result being a vastly improved and more flexible collection of split-systems.

One of the most important features of the inverter controlled range is the adoption of A Control,allowing the standardisation of the M Series and Mr Slim ranges, as well as strengthening theremote controller functionality. As a result of this it is possible to connect Mr Slim indoor units toMXZ Multi-Split outdoor units, allowing for complete design flexibility. The Mr Slim StandardInverter models have further increased the range, offering a lower cost option, whilst stillincorporating Mitsubishi Electric’s energy saving inverter technology. These models are nowalso available as a 3-phase option.

A Control is Mitsubishi Electric’s control mechanism for providing standard remote controllerfunctions alongside system diagnostics, fault code monitoring and the ability to interface withthe MELANS (Mitsubishi Electric Air Conditioning Network Solution) equipment such as theAG150 Centralised Controller, TG2000, Modbus, Trend, LonWorks® & BACnet® etc.

Page 4

Energy Saving:Reduced Power Consumption &

Increased Efficiency

Page 6: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Vector-Wave Eco InverterThis technology uses a specially designed microprocessor to produce the most efficient waveform in response to varyingcompressor motor rpm. By improving operating efficiencyfrom low to high speeds, annual electricity costs are reduced.

Power Receiver and Twin LEV ControlMitsubishi Electric has developed a power receiver and twinLEVs (linear expansion valves) that optimise the performanceof the compressor. By ensuring optimum control in responseto the operating waveform and outdoor temperature, thistechnology is tailored to the characteristics of the R410Arefrigerant to enhance operating efficiency.

Application of new technologies in MitsubishiElectric inverter systems significantly enhancethe generic benefits of inverter driven systems.

Reluctance DC Rotary CompressorsThe centralised winding DC motor uses lesscopper wiring than a conventional version and features a high density, centralised winding method that raises motor winding efficiency to 96%. Units incorporating this motor also benefit from a low starting currentas well as a stable set point.

Joint Lap DC MotorThis unique “Poki Poki” motor is manufactured using a jointlapping technique. This reliable motor operates based on ahigh density, high magnetic force, making it extremely efficient.

Highly Efficient Scroll CompressorsThe scroll compressor is equipped with a ‘Frame ComplianceMechanism’ that allows movement in the axial direction of theframe supporting the moving scroll.

This construction realises up to a 27% improvement incompressor efficiency by reducing both leakage and friction losses.

DC Fan MotorA high-efficiency DC motor drives the fan of the outdoorunits. It offers up to 60% greater efficiency than an equivalent AC motor.

Simple Partial Switching Method,PAM ControlCompared to the conventional active filter method, the simplepartial method PAM (Pulse Amplitude Modulation) controlfound on the new models helps to reduce energy losses. When combined with the Vector-Wave Eco Inverter, PAM control also allows for greater power and efficiency.

PAM adjusts the form of the current wave so that it is close tothat of the supply voltage wave. High harmonics are reducedand 98% of the electricity is utilised.

Heatexchanger

Compressor

Powerreceiver

Heatexchanger

LEV 1 LEV 2

Page 7

Energy SavingTechnology Reduced Power Consumption & Increased Eff iciency

Page 6

Normal Inver ter vs. PAM

Total Energy Conservation

Page 7: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Page 9

*1 Assuming existing pipework is suitable for R410A operational pressures *2 Not available on the MXZ-8B140VA and MXZ-8B160YA Multi-Splitoutdoor units

Page 8

Re-use ofExisting PipeworkUpgrading Existing

R22 & R407c Systems* 1

In general the upgrading of existing R22systems to modern efficient R410A systemshas been a difficult or expensive option. This is because the existing pipework wouldeither have to be replaced, or cleaned with dedicated specialist equipment.

These actions were necessary as the chlorineresidue from R22 system pipework causedchemical reactions with the lubricating oilsused in HFC compressors, the result beingpoor performance and system failure.

Mitsubishi Electric’s

Replace TechnologyThe M Series*2 & Mr Slim ranges incorporate ‘ReplaceTechnology’ to allow the upgrade of systems using existingpipe work, without the need to apply any special cleaningmachines.

M Series, S Series, Power Inverter (35/50) and StandardInverter (100/125/140) utilise Ether oil or the MitsubishiElectric patented Hard Alkyl Benzene (HAB) oil, a unique oilthat is more tolerant of contamination. By combining theseoils with developments in oil separator technology it is possiblefor these models to use existing pipework without any special operations.

All other Mr Slim models use a friction reduction “Heat Caulking” method, whereby friction inside the scrollcompressor is reduced by coating the edge of the blade, thereby suppressing the increase in temperature that causes refrigerant oil deterioration.

The Advantages of Replace Technology

For Installers

Installation time is reduced significantly

It is not necessary to purchasenew piping for R410A refrigerant

Time-consuming pipe cleaning isnot necessary when employingReplace Technology

For Tenants and Owners

Reduces installation time causingless disruption of business

Saves on installation costs

Reduced Installation

Time & Cost

Page 8: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

44kW Cooling Capacity

100

(10.0kW)

125

(12.5kW)

140

(14.0kW)

200

(19.0kW)

250

(22.0kW)

400

(38.0kW)

500

(44.0kW)

Mr Slim Power Inverter

Mr Slim Power Inverter

Mr Slim Standard Inverter

Page 11

Mr Slim Power Inverter

Model / Size

MSZ-HC-VA(B)

MSZ-GE-VA

MSZ-FD-VA

PKA-RP-HAL/KAL

MFZ-KA-VA

SEZ-KD-VAQ

PEAD-RP-JAQ

PEA-RP-GAQ

SLZ-KA-VAQ

PLA-RP-BA(2)(3)

PCA-RP-KAQ

PCA-RP-HAQ

PSA-RP-GA

Split-System Product Range Overview

M Series Inverter

(Multi-Split)

M Series Inverter

22

(2.2kW)Multi-Split only

25

(2.5kW)

35

(3.5kW)

50

(5.0kW)

60

(6.0kW)

71

(7.1kW)

0.9kW Cooling Capacity

Indoor Units

Page 10

M Series Inverter

M Series Inverter

M Series Inverter

Multi-Split

M Series Inverter

Multi-Split

M Series Inverter

Multi-Split

Outdoor Units

PUHZ-RP60/71VHA4PUHZ-P125-250V/YHA(3) PUHZ-RP35/50VHA4 PUHZ-RP100-250V/YKAPUHZ-P100V/YHA(3)MUZ-GE25-35VA

MUZ-FD25-35VABH

SUZ-KA25/35VA2

MXZ-2C52VA

MUZ-GE50VA

SUZ-KA50-60VA2

MUZ-GE60-71VA

SUZ-KA71VA2

MXZ-4C80VA

MXZ-5C100VA

MXZ-6C120VAMXZ-3C54VA

MXZ-4C71VA

MUZ-HC25-35VA(B)

Mr Slim Standard Inverter

Mr Slim Zubadan Inverter

PUHZ-HRP71-125V/YHA2

M Series Power Multi

MXZ-8B140VA

MXZ-8B160YA

Page 9: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Simple technologyat its best

Page 12

Designed tofit anywhereAvailable in a variety of options, our Split-System range fits in wherever it’sneeded. Indoor units can be four way blow cassettes, ducted, wall, floor or ceiling mounted.

Up to eight indoor units can then beconnected to a single outdoor unitproviding the ideal air conditioning solution.

The Adaptable Split-System Range

Many of our systems have an energy label of A, are registered onthe Energy Technology List and hence qualify for 100% first yearenhanced capital allowances (whole system cost and ‘reasonable’ cost of installation).

Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB.UK Conditions: Winter ; indoor 21˚C DB; outdoor -1˚C WB.

For further information please go to www.eca.gov.uk

Page 10: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

M Ser ies Room Air Conditioning

Air Conditioning Commercial Heating

Domestic Heating Photovoltaics

Page 11: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Perfect for Small to Medium Sized Applications

*1 MSZ-GE22-35VA

Page 14

The M Series Range

Designed to heat or cool small to medium sized applications, the M Series range provides a versatile, yet affordable air conditioningsolution. Quick to install and also one of the quietest units on the market (as low as19dBA*1), this newly designed, attractive rangeoffers the perfect way to ensure a comfortableenvironment with the minimum of disruption.

Surprisingly affordable, the efficiency of the M Series rangepresents substantial savings in heating mode, when comparedwith more conventional heating systems. Additional featuressuch as ‘Econo-Cool’ allow airflow to be precisely directedtowards users, allowing set temperatures to be raised by 2ºC with no loss in comfort and a 20% gain inenergy efficiency.

Flexible enough to suit a range of applications, the M Seriesrange includes models that will run up to eight indoor unitsper outdoor unit. With vastly increased pipe length and heightdifferences over its R407c predecessors, the M Series range isextremely versatile, helping to make system application easier. This diagram shows how a typical multi-split system could be installed into a medium sized office for example.

Highly Energy EfficientThe entire M Series range is now available using invertertechnology. By matching the compressor speed to the cooling or heating load of the room, up to a 30% reduction in power consumption can be achieved when compared to direct on line models.

Increasingly aware of the importance of protecting theenvironment, the M Series range is made as small as possibleto reduce raw material use and the emissions generated indistribution. The whole range also has a very high recoveryrate when recycled, so that materials can be used again at theend of the systems life. Many models also make use of a newair filtering system containing the compound Catechin, whichhelps to improve air quality and prevent the spread of bacteria and viruses.

M Series offers the end user some of the highest energyefficiency ratings available, alongside greater applicationflexibility. Lower running costs and reduced CO2 emissionsthroughout the life of the system, along with increasedcomfort for consumers are virtually guaranteed and Mitsubishi Electric has made M Series the natural choice for today’s small to medium sized application market.

Designedto Fit

Anywhere

Page 15

Page 12: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Quick Clean Design can reduce your electricity bill by approximately 30%

*1 Electricity bill comparison of operation under a fixed temperature with 8g of soil on the fan and also without.

Electricity

bill increases

by 5%*1

Electricity

bill increases

by 25%*1

Heat Exchanger Fan Air Vent

Silent OperationTechnological improvements reducing operating sound levels

Only19dBA

in‘silent mode’

*1 Mites and other allergen protein consist of sulfur atoms (S) that have bonded together.

Clean, ComfortableEnvironment

Catechin FilterCatechin is a bioflavonoid that is found in green tea.Bioflavonoids are a group of chemical substances present inmany plants, that have both antiviral and antioxidant qualities.In addition to these benefits, Catechin also offers excellentdeodorising characteristics; which is why Mitsubishi Electric usesthis compound in its air conditioning filters to not only improveair quality, but to also prevent the spread of bacteria andviruses within a room. The filter can be easily removed andwhen washed regularly, deodorising effectiveness should last for more than 10 years. MSZ-GE22-50VA / MSZ-HC wallmounted and MFZ floor mounted systems are supplied with or have the option of the Catechin filter.

Unlike conventional models with a grilled air intake, wallmounted models feature a smoothly contoured, flat panelfinish with a top air intake that not only improves aesthetics,but also helps to reduce noise as the heat exchanger area isfully covered. In fact, noise level during normal operation isonly 19dBA for the MSZ-GE22-35VA in ‘silent mode’, makingit one of the quietest indoor units on the market. This is as aresult of the multi-angled heat exchanger having a modified fin shape that reduces air resistance, producing a smoother,quieter flow of air.

Alongside this, the wide diameter of the fan produces greaterairflow at lower fan speeds and the uneven pitch betweeneach fan blade helps to eliminate unwanted noise.

“Anti-Allergy Enzyme Filter” mechanism

� Artificial enzyme catalysts on the filamentcatch the allergens.

� The artificial enzyme catalyst helps the chemicalreaction with Oxygen and severs the S-S bonds.*1

� Proteins with severed S-S bonds are no longer allergen proteins.

The vane on the MSZ-GE and MSZ-FD wall mounted models easily detaches, allowing access to the louvres. These can then beopened outwards (without any special tools) for quick cleaning of the heat exchanger, fan and air vents. Regular cleaning will increaseboth operating efficiency and energy-savings.

Quick Clean Design

Operating StatusMonitoringMonitor lamps located on the right of the indoor unit provideat-a-glance recognition of the air conditioner operating status.When the difference between the set temperature and roomtemperature is more than 2°C, both monitor lamps will turnon. If it is less than 2°C, only the upper lamp will light.

Page 16 Page 17

Page 13: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

The "I-See Sensor" automatically moves from side to side, monitoring floor temperature over a wide area of 150°.

Conventional air conditioners control indoor temperature by using only thetemperature of the intake air at the top of the room. As a result, the floor leveltemperature, which exerts such a crucial impact on the temperature thatpeople feel, tends to be overlooked. The I-See Sensor detects the floor temperatures to ensure constant comfort in the living areas.

Warm air tends to rise up from the floor level, which often prevents that zone from warming up. The I-See Sensor tracks this floor level temperature and adjusts the air outlet flow accordingly.

Plasma DeodorisationThe “Platinum catalyst deodorising filter” captures small foul-smelling substances in the air, then breaksdown the source of the odours with the power of the ozone generated in the plasma electrode unit and the platinum catalyst contained in the filter.

Plasma Electrode UnitA plasma electrode unit is mounted inside the airconditioner. Electro-discharge is used to generateozone & plasma. The collaboration betweenozone & plasma and two special filters creates a dynamic plasma air cleaning function.

Plasma Air PurificationThe “Anti-allergen electric enzyme filter” usesthe power of the static electricity charged inthe filter, as well as plasma generated in theplasma electrode unit to capture the bacteria,pollen and other allergens in the air, which arethen neutralised by the enzyme in the filter.

Mould Fighter mechanism

Step 1After cooling operation the Plasma Electrode unit fills the inside of the indoor unit with ozone (O3).

Step 2The heat exchangeris dried for about40 mins by the fanmode operation.

The MSZ-FD is equipped with a “Mould Fighter” function designed to suppress the growth ofspores of mould. The ozone generated in the plasma electrode unit attacks the mould spores,reducing mould growth by about 20%.

Cold air tends to sink to floor level, which is often the cause of over cooling. The I-See Sensor tracks this floor level temperature and adjusts the air outlet temperature accordingly.

Field Test Result: Size 35. Sweden, 23rd January 2008

The FD Series line-up is engineered forhigh energy efficiency and low soundlevels. The I-See Sensor, Plasma-Duofilter system and other superb functionsraise the comfort evel to even greater heights.

The MSZ-FD Series

High Energy EfficiencyWith the latest inverter technology, energy efficiency is improvedby about 20%. Specifically, more than 5.0 is attained for boththe COP and EER for a size 25.

Powerful Heating CapacityThe VABH outdoor unit is engineered for use in cold regions (down to -25ºC ambient) and is equipped with a powerful compressor,enabling an improvement in heating capacity. The heating power is raised by about 30% over the standard model and keeps theroom comfortable even on cold days.

Quiet RunningA larger line flow fan is included in the FD model. This allowsstable capacity with fewer rotations, reducing operating noise.

MSZ-FD

Size 25

Size 35

Side view of

MSZ-FD

Cooling

Heating

Cooling

Heating

20dBA

20dBA

21dBA

21dBA

Ø106

Page 18 Page 19

Besides a pre-filter, the MSZ-FD is also fitted with two plasma air-purifying functions. These functions are engineered to changeair dirt particles from micron to nano-size in scale.

Page 14: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Outdoor Unit

Branch Box

Branch Box

Example of aPower Multi system

using eight indoor units

� 14kW and 15.5kW Inverter Multi Systems, based on Mr Slim Power Inverter technology

� Ability to connect up to eight indoor units acrossthe M Series and Mr Slim product range within amaximum capacity index of 20.2kW

� Total Pipe Length of 115m / Height Difference of 30m

� Single and 3 phase power supplies available

� Connection of indoor units is through either a 3-way(PAC-AK31BC) or 5-way (PAC-AK52BC) branch box,either singularly or with two in combination

� Individual control of each indoor unit is now possible(ON/OFF and Setpoint)

� Low starting and running currents

� Connection to M-NET system via MAC-399IFinterface (one per indoor unit needed)

The MXZ-8B Power Multi Inver ter Heat Pump Multi-Split Outdoor Units

MXZ Multi-Split Systems

Ideal for apartments or small commercial buildings

All Mitsubishi

Electric MXZ

multi-split outdoor

models have an

energy label

of ‘A’

Page 20 Page 21

Page 15: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Excellent FeaturesAvailable in wall and floor mounted, the M Series range is quiet, economicto run and easy to install. The outdoorunits can run up to eight indoor units, allcontrolled with a simple remote controller.

Whatever your requirements may be,Mitsubishi Electric offers the perfectair conditioning solution for any situation.

Page 22

MSZ-HC-VA(B) Inverter Heat Pump, Wall Mounted System

MSZ-GE-VA Inverter Heat Pump, Wall Mounted System

MSZ-FD-VA Inverter Heat Pump, Wall Mounted System

MFZ-KA-VA Inverter Heat Pump, Floor Mounted System

MXZ-C-VA Multi-Split Inverter Heat Pump

MXZ-8B-VA/YA Power Multi Inverter Heat Pump

Outdoor Units

M Series Accessories / Optional Extras

24

26

28

30

32

34

60

62

Contents

Page 23

Simple technologyat its best

Many of our systems have an energy label of A, are registered onthe Energy Technology List and hence qualify for 100% first yearenhanced capital allowances (whole system cost and ‘reasonable’cost of installation).

Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB.UK Conditions: Winter ; indoor 21˚C DB; outdoor -1˚C WB.

For further information please go to www.eca.gov.uk

Page 16: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

MSZ-HC-VA(B) Inverter Heat Pump

Mitsubishi Electric’s range of high specification, flat panel wall mountedmodels make use of inverter technology, whilst providing extremely goodvalue for money, costing approximately 20% less than the MSZ-G equivalent.

These units have extremely quiet sound levels, whilst also deliveringeconomical air conditioning, with improved COP/EER figures and in many cases corresponding ‘A’ rated energy labels.

* Catechin filter is optional

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Heating/Cooling - Lo-Mi-Hi-SupHi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Heating/Cooling - Lo-Mi-Hi-SupHi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

RUNNING CURRENT (A)

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

MSZ-HC-VA(B) - INDOOR UNITS

MSZ-HC25VA

3.2 (0.9-4.4)

2.5 (0.9-3.0)

2.65 (0.75-3.65)

2.5 (0.9-3.0)

0.79

3.64 / 3.25

A / A

5.1-6.5-7.8-9.1 / 5.3-7.0-8.7-10.5

9.52(3/8”)

6.35(1/4”)

26-32-38-43 / 26-32-38-43

788

225

295

9

Fed by Outdoor Unit

Single

0.22

6

4

MSZ-HC35VAB

3.6 (0.9-4.8)

3.4 (1.0-3.7)

3.0 (0.75-4.0)

3.35 (1.0-3.65)

0.76

3.62 / 3.01

A / B

4.9-6.7-8.0-9.2 / 5.2-6.8-8.4-10.2

9.52(3/8”)

6.35(1/4”)

26-32-38-43 / 26-32-38-43

788

225

295

9

Fed by Outdoor Unit

Single

0.22

6

4

MODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. CORES

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 7m

MUZ-HC-VA(B) - OUTDOOR UNITS

MUZ-HC25VA

47 / 46

25

684

255

540

220-240v, 50Hz

Single

0.88 / 0.77

0.801 / 0.616

4.2

4.2 / 3.7 [5.5]

10

3

10

5

0.73

MUZ-HC35VAB

48 / 47

25

684

255

540

220-240v, 50Hz

Single

0.995 / 1.13

0.905 / 0.904

5.3

4.8 / 5.3 [6.5]

10

3

10

5

0.75

Technical Information

Page 24

Classic Wall Mounted System

MSZ

-HC

-VA

(B)

Inve

rter

Hea

t Pu

mp

INDOOR UNIT MSZ-HC25/35VA(B)

Upper View >

Front View > Side View >

M S

eri

es

Ran

ge

Dimensions

Page 25

Page 17: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

76 843 181

325

65

67310

0

125

160

( 70∞)

238

5

184

12

Air out

Air in

1090 5

1100

MSZ

-GE-

VA

Inve

rter

Hea

t Pu

mp

INDOOR UNIT MSZ-GE22-50VA

INDOOR UNIT MSZ-GE60/71VA

Front View >

Side View >

Upper View >

Front View >

Side View >

Upper View >

Dimensions

Page 27

M S

eri

es

Ran

ge

MSZ-GE-VA - INDOOR UNITS

MSZ-GE-VA Inverter Heat Pump

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Heating - Sil-Lo-Mi-Hi-SupHi-SupHiLP

Cooling - Sil-Lo-Mi-Hi-SupHi-SupHiLP

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Heating - Sil-Lo-Mi-Hi-SupHi-SupHiLP

Cooling - Sil-Lo-Mi-Hi-SupHi-SupHiLP

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) – HRC (A)

INTERCONNECTING CABLE No. CORES

MUZ-GE-VA - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) – HRC (A)

MAINS CABLE No. CORES

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 7m

MSZ-GE60VA

6.8 (2.0-9.3)

6.0 (1.5-7.5)

5.65 (1.65-7.75)

5.95 (1.5-7.45)

0.79

3.84 / 3.40

A / A

9.8-11.3-13.4-15.6-18.3-20.7

9.8-11.3-13.4-15.6-18.3-20.7

15.88 (5/8”)

6.35 (1/4”)

29-37-41-45-49-52

29-37-41-45-49-52

1100

238

325

16

Fed by Outdoor Unit

Single

6

4

MSZ-GE71VA

8.1 (2.2-9.9)

7.1 (2.4-8.7)

6.75 (1.85-8.25)

7.05 (2.4-8.65)

0.78

3.83 / 3.33

A / A

10.2-11.5-13.3-15.4-17.8-19.4

9.7-11.5-13.3-15.4-17.8-19.4

15.88 (5/8”)

9.52 (3/8”)

30-37-41-45-49-52

30-37-41-45-49-53

1100

238

325

16

Fed by Outdoor Unit

Single

6

4

MSZ-GE50VA

5.8 (1.4-7.3)

5.0 (1.4-5.5)

4.8 (1.15-6.05)

4.95 (1.4-5.45)

0.76

3.71 / 3.30

A / A

6.5-7.8-9.6-12.2-14.5

6.5-7.8-9.6-11.9-15.1

12.7 (1/2”)

6.35 (1/4”)

28-33-37-43-48

28-33-38-44-49

798

232

295

10

Fed by Outdoor Unit

Single

6

4

MSZ-GE22VA

3.3 (0.9-4.0)

2.2 (0.9-3.0)

2.75 (0.75-3.3)

2.2 (0.9-3.0)

-

-

-

4.1-4.6-6.6-9.1-11.5

4.1-4.6-6.7-9.2-11.3

9.52 (3/8”)

6.35 (1/4”)

19-21-29-36-42

19-21-29-36-42

798

232

295

10

Fed by Outdoor Unit

Single

6

4

MSZ-GE25VA

3.2 (1.3-4.5)

2.5 (1.1-3.5)

2.65 (1.1-3.75)

2.5 (1.1-3.45)

0.96

4.57 / 4.59

A / A

4.1-4.8-6.6-9.1-11.5

4.1-4.8-6.7-9.1-11.3

9.52 (3/8”)

6.35 (1/4”)

19-21-29-36-42

19-21-29-36-42

798

232

295

10

Fed by Outdoor Unit

Single

6

4

MSZ-GE35VA

4.0 (1.6-5.3)

3.5 (1.1-4.0)

3.3 (1.35-4.4)

3.45 (1.1-3.95)

0.82

4.19 / 4.05

A / A

4.1-4.8-6.7-9.1-11.5

4.1-4.8-6.7-9.1-12.7

9.52 (3/8”)

6.35 (1/4”)

19-22-30-36-42

19-22-30-36-43

798

232

295

10

Fed by Outdoor Unit

Single

6

4

MUZ-GE60VA

55 / 55

50

840

330

880

220-240v, 50Hz

1.77 / 1.76

1.611 / 1.408

7.9

7.9 / 7.8 [14.5]

16

3

30

15

1.55

MUZ-GE71VA

55 / 55

53

840

330

880

220-240v, 50Hz

2.11 / 2.13

1.92 / 1.704

9.4

9.4 / 9.3 [16.6]

20

3

30

15

1.9

MUZ-GE50VA

56 / 54

54

840

330

850

220-240v, 50Hz

1.565 / 1.515

1.424 / 1.212

7.0

7.0 / 6.8 [13]

16

3

30

15

1.55

N/A Multi-Split Only

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

MUZ-GE25VA

48 / 47

30

800

285

550

220-240v, 50Hz

0.70 / 0.545

0.637 / 0.436

3.7

3.7 / 2.9 [7.4]

10

3

20

12

0.8

MUZ-GE35VA

48 / 47

33

800

285

550

220-240v, 50Hz

0.955 / 0.865

0.869 / 0.692

4.6

4.6 / 4.2 [8.6]

10

3

20

12

1.15

Technical Information

Page 26

The MSZ series has been completely redesignedand features the new Nano Platinum filter system.

These models offer industry leading noise levels as low as 19dBA and have a distinctivelystyled front panel that not only looks appealing, but also helps to make cleaning of the unit easier.

Wall Mounted System

* Wide swing & long airflow mode available for MSZ-GE60/71VA * The anti-allergy enzyme filter is optional* Nano Platinum filter available for MSZ-GE60/71VA, Catechin filter available for MSZ-GE22-50VA

Page 18: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

MSZ

-FD

-VA

Inve

rter

Hea

t Pu

mp

INDOOR UNIT MSZ-FD25/35VA

Front View > Side View >

Upper View >

Dimensions

Page 29

M S

eri

es

Ran

ge

MSZ-FD-VA - INDOOR UNITS

MSZ-FD-VA Inverter Heat Pump

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Heating/Cooling - Lo-Mi-Hi-SupHi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Heating/Cooling - Lo-Mi-Hi-SupHi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) – HRC (A)

INTERCONNECTING CABLE No. CORES

MUZ-FD-VABH - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) – HRC (A)

MAINS CABLE No. CORES

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 7m

MSZ-FD25VA3.2 (1.5-6.3)

2.5 (1.1-3.5)

2.65 (1.25-5.25)

2.5 (1.1-3.45)

0.85

5.33 / 5.15

A / A

4.5-6.7-9.2-12.1 / 4.6-6.3-8.6-11.2

9.52 (3/8”)

6.35 (1/4”)

20-29-36-43 / 20-29-36-42

798

257

295

12

Fed by Outdoor Unit

Single

6

4

MSZ-FD35VA4.0 (1.3-6.6)

3.5 (0.8-4.0)

3.3 (1.1-5.5)

3.45 (0.8-3.95)

0.85

4.76 / 4.19

A / A

4.7-6.7-9.2-12.5 / 4.6-6.3-8.6-11.2

9.52 (3/8”)

6.35 (1/4”)

21-29-36-44 / 21-29-36-43

798

257

295

12

Fed by Outdoor Unit

Single

6

4

MUZ-FD25VABH

46 / 46

36

800

285

550

220-240v, 50Hz

0.60 / 0.485

0.546 / 0.388

2.9

2.9 / 2.4 [10]

10

3

20

12

1.15

MUZ-FD35VABH

50 / 47

36

800

285

550

220-240v, 50Hz

0.84 / 0.835

0.764 / 0.668

3.9

3.9 / 3.8 [10.5]

16

3

20

12

1.15

Technical Information

Page 28

The MSZ-FD series is our most energy efficient M Series wall mounted unit to date. These high COP models feature the new Plasma Duo filter system. They also offer industryleading noise levels and have a distinctively styled front panelthat not only looks appealing but also helps to make cleaningof the unit easier.

Also incorporated is an ‘I-See Sensor’, providingeven temperature distribution and furtherreducing energy consumption.

Wall Mounted System

Page 19: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

MFZ

-KA

-VA

Inve

rter

Hea

t Pu

mp

INDOOR UNIT MFZ-KA25-50VA

Front View >

Upper View >

Side View >

Dimensions

Page 31

M S

eri

es

Ran

ge

MFZ-KA-VA - INDOOR UNITS

MFZ-KA-VA Inverter Heat Pump

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGY LABEL Heating/Cooling

AIRFLOW (m3/min) Heating/Cooling - Lo-Mi-Hi-SupHi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Heating/Cooling - Lo-Mi-Hi-SupHi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

FUSE RATING (BS88) – HRC (A)

INTERCONNECTING CABLE No. CORES

SUZ-KA-VA2 - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

SYSTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SYSTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. CORES

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 7m

MFZ-KA25VA

3.4 (0.9-5.1)

2.5 (0.9-3.4)

2.85 (0.75-4.25)

2.5 (0.9-3.35)

0.66

4.07 / 4.31

A / A

5.0-6.2-7.6-9.4 / 4.8-5.8-7.1-8.9

9.52 (3/8”)

6.35 (1/4”)

22-27-32-37 / 22-27-32-37

700

200

600

14

Fed by Outdoor Unit

Single

6

4

MFZ-KA35VA

4.0 (0.9-6.2)

3.5 (0.9-3.9)

3.3 (0.75-5.15)

3.45 (0.9-3.85)

0.65

3.64 / 3.21

A / A

5.2-6.2-7.8-9.5 / 5.0-6.1-7.4-9.1

9.52 (3/8”)

6.35 (1/4”)

25-28-33-38 / 23-28-33-38

700

200

600

14

Fed by Outdoor Unit

Single

6

4

MFZ-KA50VA

6.0 (0.9-7.9)

4.8 (0.9-5.4)

5.0 (0.75-6.55)

4.75 (0.9-5.35)

0.63

3.23 / 3.10

C / B

7.4-8.8-9.8-12.3 / 7.1-7.9-9.2-11.2

12.7 (1/2”)

6.35 (1/4”)

32-35-39-44 / 32-35-39-43

700

200

600

14

Fed by Outdoor Unit

Single

6

4

SUZ-KA25VA2

46 / 46

33

800

285

550

220-240v, 50Hz

0.835 / 0.58

0.76 / 0.46

3.65

3.85 / 3.25 [8.4]

10

3

20

12

0.8

SUZ-KA35VA2

48 / 47

37

800

285

550

220-240v, 50Hz

1.10 / 1.09

1.00 / 0.87

4.75

4.95 / 4.75 [9.4]

10

3

20

12

1.05

SUZ-KA50VA2

55 / 53

53

840

330

850

220-240v, 50Hz

1.86 / 1.55

1.69 / 1.24

6.75

6.55 / 6.95 [16.2]

20

3

30

15

1.6

Technical Information

Page 30

The MFZ-KA-VA series is extremely versatileand is designed for wall attached installationat floor level. The auto swing vane providesa more natural and comfortable airflowthroughout the room and the lightweight, compact design makes installation easy.

Floor Mounted System

* The anti-allergy enzyme filter is optional

Page 20: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

MX

Z-C

-VA

M

ulti-

Split

Inve

rter

Hea

t Pu

mp

(5.2

-12k

W)

OUTDOOR UNIT MXZ-2C52VA

Front View > Side View >Upper View >

Indoor and outdoor connect wiring 39 x 27 hole

27.1

23.1

440

45

315

84

299

360

710

840 30200

240

330 1330

66.3

D unit connection

C unit connection

B unit connection

A unit connection

Air in

Air in

Air out

(Bol

t Pitc

h)

171500

360.

6

20.3

13.3

16.8 31

.3

63.2 288233.1

169

396

17.7

17.7

OUTDOOR UNIT MXZ-3C54VA / MXZ-4C71VA

D connection for MXZ-4B71VA

460

317

900

900

23

597

132

405

45

Indoor and outdoorconnect wiring (35 x 53) hole

32030 10

88

D unit connectionE unit connection

C unit connectionB unit connection

A unit connection

Air out

3574

200 200500

35 250 270

355

(Bol

t pitc

h)38

7

4027 16

1611

24

Air in

Air in

OUTDOOR UNIT MXZ-4C80VA / MXZ-5C100VA

E connection for MXZ-5B100VA

Dimensions

Page 33

M S

eri

es

Ran

ge

Front View > Side View >Upper View >

Front View > Side View >Upper View >

OUTDOOR UNIT MXZ-6C120VA

Front View > Side View >Upper View >

MXZ-C-VA - OUTDOOR UNITS

MXZ-C-VA Inverter Heat Pump (5.2 - 12kW)

MODEL REFERENCE

NUMBER OF CONNECTABLE INDOOR UNITS

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

COP / EER (nominal) Outdoor Only

ENERGy LABEL Heating/Cooling

MAX AIRFLOW (m3/min) Heating/Cooling

NOISE (dBA) Heating/Cooling - Sil-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLy

POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

RUNNING CURRENT (A) [MAX] Heating/Cooling

INTERCONNECTING CABLE No. CORES

TOTAL PIPE LENGTH (m)

MAX PIPE LENGTH PER INDOOR UNIT (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) [Precharged Length]

FUSE RATING (BS88) – HRC (A)

MXZ-3C54VA

2 - 3

7.0 (2.6-9.0)

5.4 (2.9-6.8)

5.8 (2.15-7.5)

5.35 (2.9-6.75)

5.04 / 4.23

A / A

43 / 42.1

48-51 / 45-47

840

330

710

57

220-240v, 50Hz

1.465 / 1.19

1.33 / 0.95

6.43

6.43 / 5.23 [15]

4 Core

50

25

15 (10 if OU higher than IU)

2.7 [40m]

25

MXZ-4C71VA

2 - 4

8.6 (3.4-10.7)

7.1 (3.7-8.8)

7.15 (2.85-8.9)

7.05 (3.65-8.75)

4.78 / 4.54

A / A

43 / 42.1

48-52 / 45-48

840

330

710

58

220-240v, 50Hz

1.705 / 1.68

1.55 / 1.34

7.49

7.49 / 7.38 [15]

4 Core

60

25

15 (10 if OU higher than IU)

2.7 [40m]

25

MXZ-5C100VA

2 - 5

12.0 (4.1-14.0)

10.0 (3.9-11.0)

9.95 (3.4-11.65)

9.9 (3.85-10.9)

4.23 / 3.57

A / A

59.3 / 56.6

47-54 / 46-51

900

320

900

68

220-240v, 50Hz

2.835 / 2.88

2.58 / 2.30

12.45

12.45 / 12.30 [18.4]

4 Core

80

25

15 (10 if OU higher than IU)

4.0 [40m]

25

MXZ-6C120VA

2 - 6

14.0 (3.5-16.5)

12.0 (3.5-13.5)

11.65 (2.9-13.7)

11.9 (3.45-13.4)

3.88 / 3.21

A / A

59.5 / 69.9

53-57 / 51-55

900

320

1070

88

220-240v, 50Hz

3.47 / 3.61

3.16 / 2.89

15.85

15.24 / 15.85 [27]

4 Core

80

25

15 (10 if OU higher than IU)

5.0 [60m]

40

MXZ-2C52VA

2

6.4 (1.0-7.0)

5.2 (1.1-6.0)

5.3 (0.85-5.8)

5.15 (1.1-5.95)

3.98 / 4.00

A / A

33.3 / 32.9

49-50 / 46-49

800

285

550

38

220-240v, 50Hz

1.61 / 1.30

1.47 / 1.04

7.22

7.22 / 5.83 [10.2]

4 Core

30

20

15 (10 if OU higher than IU)

1.3 [20m]

16

MXZ-4C80VA

2 - 4

9.4 (3.4-11.6)

8.0 (3.7-9.2)

7.8 (2.85-9.65)

7.95 (3.65-9.15)

4.87 / 4.09

A / A

43.8 / 42.2

46-48 / 44-46

900

320

900

67

220-240v, 50Hz

1.93 / 1.955

1.76 / 1.56

8.59

8.48 / 8.59 [17.4]

4 Core

70

25

15 (10 if OU higher than IU)

3.5 [40m]

25

MULTI-SPLIT - INDOOR UNITS

MODEL REFERENCE

MSZ-GE22/25/35/50VAMSZ-FD25/35VA

MSZ-EF25/35/50VEBMFZ-KA25/35/50VA

SEZ-KD25/35/50VAQ

PEAD-RP50JAQ*1

SLZ-KA25/35/50VAQ

PLA-RP50BAMXZ-3C54VA

MSZ-GE22/25/35VAMSZ-FD25/35VAMSZ-EF25/35VEB

MFZ-KA25/35VA SEZ-KD25/35VAQ SLZ-KA25/35VAQ -MXZ-2C52VA

MFZ-KA25/35/50VASEZ-KD25/35/50/60VAQ

PEAD-RP50JAQ*1

SLZ-KA25/35/50VAQ

PLA-RP50/60BAMXZ-4C71VA

MSZ-GE22/25/35/50/60/71VAMSZ-FD25/35VA

MSZ-EF25/35/50VEBMFZ-KA25/35/50VA

SEZ-KD25/35/50/60/71VAQ

PEAD-RP50/60/71JAQ*1

SLZ-KA25/35/50VAQ

PLA-RP50/60/71BA(2)MXZ-4C80VA

MSZ-GE22/25/35/50/60/71VAMSZ-FD25/35VA

MSZ-EF25/35/50VEBMFZ-KA25/35/50VA

SEZ-KD25/35/50/60/71VAQ

PEAD-RP50/60/71JAQ*1

SLZ-KA25/35/50VAQ

PLA-RP50/60/71BA(2)MXZ-5C100VA

MSZ-GE22/25/35/50/60/71VAMSZ-FD25/35VA

MSZ-EF25/35/50VEBMFZ-KA25/35/50VA

SEZ-KD25/35/50/60/71VAQ

PEAD-RP50/60/71JAQ*1

SLZ-KA25/35/50VAQ

PLA-RP50/60/71BA(2)MXZ-6C120VA

WALL MOUNTED FLOOR MOUNTED DUCTED CEILING CASSETTE

PCA-RP50KAQ

PCA-RP50/60KAQ

PCA-RP50/60/71KAQ

PCA-RP50/60/71KAQ

PCA-RP50/60/71KAQ

CEILING SUSPENDED

� Up to six indoor units may be connected to a single outdoor unit

� Energy saving inverter controlled outdoor unit adjusts compressorperformance to economically match the demand for heating and cooling

� Units may be added within the capacity of the system as requirements change

� Capacities of indoor units may be mixed to suit individual rooms

� New size 80, 100 and 120 have current limit adjustment for managingenergy costs. They also feature a wiring/piping correction function toanalyse the system for connection errors via the press of a single button

Technical Information

Page 32

The multi-split system allows up to six M Series or Mr Slim wall mounted,cassette, ducted, floor or ceiling mounted indoor unit heat pumps of differentcapacities to be operated from a single outdoor unit. This makes it an economicanswer in multi-room applications, whilst also offering space saving benefits.

Multi-Split Units

MSZ-GE22/25/35/50/60VAMSZ-FD25/35VA

MSZ-EF25/35/50VEB

*1 Combined max running current of all indoors on system must not exceed 3A if PEAD-RP is used

Page 21: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

MX

Z-8

B-V

A/Y

APower M

ulti Inverter H

eat Pump (14-15.5kW

)

OUTDOOR UNIT MXZ-8B140VA / MXZ-8B160YA

Front View > Side View >

Front View > Side View >

Upper View >

to indoor unit55

198 65

39

25 25 25 25 25 21

75 75 75 75

E D C B A

E D C B A

91

73

450 95 280 39

61 79 50 34

7035

68

320

402

24

12

Upper View >

Front View > Side View >

205

198 65

39

25 25 25 21

75 75

91

73

C B A

C B A

450

to indoor unit

95

61 79 50 34

39280

7035

68

320

402

24

12

Upper View >

BRANCH BOX PAC-AK31BC

BRANCH BOX PAC-AK52BC

Dimensions

Page 35

M S

eri

esRange

MXZ-8B-VA/YA - OUTDOOR UNITS

MXZ-8B-VA/YA Power Multi (14-15.5kW)

MODEL REFERENCE

NUMBER OF CONNECTABLE INDOOR UNITS

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

COP / EER (nominal) Outdoor Only

ENERGY LABEL Heating/Cooling

MAX AIRFLOW (m3/min)

NOISE (dBA) Heating/Cooling - Sil-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLY

PHASE

POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

RUNNING CURRENT (A) [MAX] Heating/Cooling

INTERCONNECTING CABLE No. CORES

TOTAL PIPE LENGTH (m)

MAX PIPE LENGTH PER INDOOR UNIT (m)

FURTHEST PIPE LENGTH - Outdoor to Indoor (m)

MAX HEIGHT DIFFERENCE - Outdoor to Indoor (m)

MAX HEIGHT DIFFERENCE - Indoor to Indoor (m)

CHARGE R410A (kg) - 40m

FUSE RATING (BS88) – HRC (A)

MXZ-8B140VA

2 - 8

16.0

14.0

13.3

13.9

3.91 / 3.52

A / A

100

52 / 47-50

950

330

1350

129

220-240v, 50Hz

Single

3.90 / 3.79

3.55 / 3.03

14

17.05 / 16.55 [29.5]

4 Core

115

15 (from Branch Box)

70

30 (20 if OU lower than IU)

12

8.5

40

PAC-AK31BC

1 - 3

From Outdoor Unit

From Branch Box

15.88(5/8”)

9.52(3/8”)

55

60

30

15

450

280

198

PAC-AK31BC - BRANCH BOX

MODEL REFERENCE

NUMBER OF CONNECTABLE INDOOR UNITS

POWER SUPPLY TO BRANCH BOX

POWER SUPPLY TO INDOOR UNITS

PIPE SIZE mm(in) Main Outdoor Side - Gas

PIPE SIZE mm(in) Main Outdoor Side - Liquid

MAX PIPE LENGTH - Outdoor Unit to Branch Box (m)

TOTAL PIPE LENGTH - Branch Boxes to Indoor Unit (m)

MAX HEIGHT DIFFERENCE - Outdoor Unit to Branch Box (m)

MAX HEIGHT DIFFERENCE - Branch Box to Indoor Unit (m)

DIMENSIONS (mm) Width

Depth

Height

PAC-AK52BC

1 - 5

From Outdoor Unit

From Branch Box

15.88(5/8”)

9.52(3/8”)

55

60

30

15

450

280

198

PAC-AK52BC - BRANCH BOX

MODEL REFERENCE

NUMBER OF CONNECTABLE INDOOR UNITS

POWER SUPPLY TO BRANCH BOX

POWER SUPPLY TO INDOOR UNITS

PIPE SIZE mm(in) Main Outdoor Side - Gas

PIPE SIZE mm(in) Main Outdoor Side - Liquid

MAX PIPE LENGTH - Outdoor Unit to Branch Box (m)

TOTAL PIPE LENGTH - Branch Boxes to Indoor Unit (m)

MAX HEIGHT DIFFERENCE - Outdoor Unit to Branch Box (m)

MAX HEIGHT DIFFERENCE - Branch Box to Indoor Unit (m)

DIMENSIONS (mm) Width

Depth

Height

MULTI-SPLIT - INDOOR UNITS

MODEL REFERENCE

MSZ-GE22/25/35/50/60/71VAMSZ-FD25/35VA

MSZ-EF25/35/50VEBMFZ-KA25/35/50VA

SEZ-KD25/35/50/60/71VAQ

PEAD-RP50/60/71JAQ*1

SLZ-KA25/35/50VAQ

PLA-RP35/50/60/71BA(2)

PLA-RP100BA(3)*2

MXZ-8B140VA

MSZ-GE22/25/35/50/60/71VAMSZ-FD25/35VA

MSZ-EF25/35/50VEBMFZ-KA25/35/50VA

SEZ-KD25/35/50/60/71VAQ

PEAD-RP50/60/71JAQ*1

SLZ-KA25/35/50VAQ

PLA-RP35/50/60/71BA(2)

PLA-RP100BA(3)*2

MXZ-8B160YA

WALL MOUNTED FLOOR MOUNTED DUCTED CEILING CASSETTE

� 14 and 15.5kW Inverter Multi Systems, based on Mr Slim Power Inverter technology

� Total Pipe length of 115m / Height difference of 30m

� Individual control of each indoor unit is now possible (ON/OFF & Setpoint)

� Low starting and running currents

� Connection to M-NET system via MAC-399IF interface (one per indoor unit)

� Current limit adjustment for managing energy costs

Technical Information

Page 34

The Power Multi systems allow up to eight M Series or Mr Slim cassette, ducted,floor, ceiling or wall mounted indoor units of different capacities to be operatedfrom a single outdoor unit, making use of two types of branch box to achieve this.This makes them an economic answer in multi-room applications and ideal forapartments or small commercial buildings.

Inverter Heat Pump Multi-Split Units

*1Total capacity of indoor units must not exceed 100% if PEAD-RP is used *2 Can only be connected using a PAC-AK52BC with a PAC-AK52YP-E pipe

MXZ-8B160YA

2 - 8

18.0

15.5

14.95

15.4

3.61 / 3.21

A / A

106

54 / 48-51

950

330

1350

139

380-415v, 50Hz

3

4.80 / 4.64

4.37 / 3.71

7

7.00 / 6.77 [13]

4 Core

115

15 (from Branch Box)

70

30 (20 if OU lower than IU)

12

8.5

25

Page 22: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

MXZ-8B140VAMXZ-8B160YAPower Multi units

MXZ-4C80VAMXZ-5C100VAInverter Multi units

MXZ-6C120VAInverter Multi unit

MXZ-3C54VAMXZ-4C71VAInverter Multi units

Page 36

Multi-Split Systems8 Outdoor Units 32 Indoor Units

MXZ-2C52VAInverter Multi unit

PCA-RP-KAQ Series

PEAD-RP-JAQ Series

SEZ-KD-VAQ Series

SLZ-KA-VAQ Series

PLA-RP-BA(2)(3) Series

MFZ-KA-VA Series

MSZ-FD-VA Series

MSZ-GE-VA Series

Multi-Split systems allow upto eight M Series or Mr Slim cassette, ducted, floor, ceilingor wall mounted indoor unitsof different capacitiesto be operated froma single outdoor unit.

Page 37

Page 23: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

1 ROOM22

25

35

50

60

71

2 ROOMS22 + 22

22 + 25

22 + 35

22 + 50

22 + 60

22 + 71

25 + 25

25 + 35

25 + 50

25 + 60

25 + 71

35 + 35

35 + 50

Unit A

2.20 / 3.30

2.50 / 3.60

3.50 / 4.00

5.00 / 7.20

6.00 / 7.90

7.10 / 8.60

2.20 / 3.30

2.20 / 3.23

2.20 / 2.89

2.20 / 2.51

2.09 / 2.52

1.87 / 2.22

2.50 / 3.60

2.50 / 3.17

2.50 / 2.87

2.29 / 2.76

2.06 / 2.45

3.50 / 4.00

3.21 / 3.87

Unit B

2.20 / 3.30

2.50 / 3.67

3.50 / 4.61

5.00 / 5.69

5.71 / 6.88

6.03 / 7.18

2.50 / 3.60

3.50 / 4.43

5.00 / 5.73

5.51 / 6.64

5.84 / 6.95

3.50 / 4.00

4.59 / 5.53

Unit C Unit D

Indoor unitcombination

Cooling / Heating Capacity (kW)

MXZ-4C80VA1Outdoor Unit Up to 4 Indoor Units

35 + 60

35 + 71

50 + 50

50 + 60

50 + 71

60 + 60

60 + 71

3 ROOMS

22 + 22 + 22

22 + 22 + 25

22 + 22 + 35

22 + 22 + 50

22 + 22 + 60

22 + 22 + 71

22 + 25 + 25

22 + 25 + 35

22 + 25 + 50

22 + 25 + 60

22 + 25 + 71

22 + 35 + 35

22 + 35 + 50

22 + 35 + 60

22 + 35 + 71

22 + 50 + 50

22 + 50 + 60

22 + 50 + 71

25 + 25 + 25

25 + 25 + 35

25 + 25 + 50

25 + 25 + 60

25 + 25 + 71

25 + 35 + 35

25 + 35 + 50

25 + 35 + 60

25 + 35 + 71

25 + 50 + 50

25 + 50 + 60

35 + 35 + 35

35 + 35 + 50

35 + 35 + 60

35 + 35 + 71

35 + 50 + 50

35 + 50 + 60

Unit A

2.91 / 3.46

2.61 / 3.10

3.95 / 4.70

3.64 / 4.27

3.31 / 3.88

4.00 / 4.70

3.66 / 4.31

2.20 / 2.90

2.20 / 2.81

2.14 / 2.56

1.83 / 2.20

1.67 / 1.99

1.53 / 1.80

2.20 / 2.72

2.07 / 2.50

1.79 / 2.13

1.64 / 1.93

1.49 / 1.75

1.87 / 2.25

1.64 / 1.93

1.50 / 1.77

1.38 / 1.62

1.44 / 1.70

1.33 / 1.57

1.23 / 1.45

2.50 / 3.00

2.29 / 2.76

1.98 / 2.35

1.82 / 2.14

1.65 / 1.94

2.08 / 2.47

1.82 / 2.14

1.67 / 1.96

1.53 / 1.79

1.60 / 1.88

1.48 / 1.74

2.65 / 3.13

2.33 / 2.74

2.15 / 2.53

1.99 / 2.33

2.07 / 2.44

1.93 / 2.27

Unit B

4.99 / 5.94

5.29 / 6.30

3.95 / 4.70

4.36 / 5.13

4.69 / 5.52

4.00 / 4.70

4.34 / 5.09

2.20 / 2.90

2.20 / 2.81

2.14 / 2.56

1.83 / 2.20

1.67 / 1.99

1.53 / 1.80

2.50 / 3.09

2.35 / 2.84

2.04 / 2.42

1.87 / 2.20

1.69 / 1.99

2.97 / 3.58

2.62 / 3.07

2.39 / 2.81

2.19 / 2.57

3.28 / 3.85

3.03 / 3.56

2.80 / 3.29

2.50 / 3.00

2.29 / 2.76

1.98 / 2.35

1.82 / 2.14

1.65 / 1.94

2.91 / 3.46

2.55 / 2.99

2.33 / 2.74

2.14 / 2.51

3.20 / 3.76

2.96 / 3.48

2.65 / 3.13

2.33 / 2.74

2.15 / 2.53

1.99 / 2.33

2.96 / 3.48

2.76 / 3.24

Unit C

2.20 / 2.90

2.50 / 3.19

3.41 / 4.08

4.15 / 5.00

4.56 / 5.42

4.94 / 5.80

2.50 / 3.09

3.29 / 3.97

4.07 / 4.85

4.49 / 5.27

4.81 / 5.66

2.97 / 3.58

3.74 / 4.39

4.10 / 4.82

4.44 / 5.21

3.28 / 3.85

3.64 / 4.27

3.97 / 4.67

2.50 / 3.00

3.21 / 3.87

3.95 / 4.70

4.36 / 5.13

4.69 / 5.52

2.91 / 3.46

3.64 / 4.27

4.00 / 4.70

4.34 / 5.09

3.20 / 3.76

3.56 / 4.18

2.65 / 3.13

3.33 / 3.92

3.69 / 4.34

4.03 / 4.73

2.96 / 3.48

3.31 / 3.89

Unit D

Indoor unitcombination

Cooling / Heating Capacity (kW)

4 ROOMS22 + 22 + 22 + 22

22 + 22 + 22 + 25

22 + 22 + 22 + 35

22 + 22 + 22 + 50

22 + 22 + 25 + 25

22 + 22 + 25 + 35

22 + 22 + 25 + 50

22 + 22 + 35 + 35

22 + 25 + 25 + 25

22 + 25 + 25 + 35

22 + 25 + 25 + 50

22 + 25 + 35 + 35

25 + 25 + 25 + 25

25 + 25 + 25 + 35

25 + 25 + 25 + 50

25 + 25 + 35 + 35

Unit A

1.78 / 2.15

1.72 / 2.08

1.55 / 1.87

1.35 / 1.63

1.66 / 2.01

1.50 / 1.82

1.31 / 1.59

1.37 / 1.66

1.61 / 1.95

1.46 / 1.77

1.28 / 1.55

1.34 / 1.62

1.78 / 2.15

1.61 / 1.95

1.42 / 1.72

1.48 / 1.79

Unit B

1.78 / 2.15

1.72 / 2.08

1.55 / 1.87

1.35 / 1.63

1.66 / 2.01

1.50 / 1.82

1.31 / 1.59

1.37 / 1.66

1.83 / 2.22

1.66 / 2.01

1.45 / 1.76

1.52 / 1.84

1.78 / 2.15

1.61 / 1.95

1.42 / 1.72

1.48 / 1.79

Unit C

1.78 / 2.15

1.72 / 2.08

1.55 / 1.87

1.35 / 1.63

1.89 / 2.29

1.71 / 2.07

1.49 / 1.81

2.18 / 2.64

1.83 / 2.22

1.66 / 2.01

1.45 / 1.76

2.12 / 2.57

1.78 / 2.15

1.61 / 1.95

1.42 / 1.72

2.07 / 2.51

Unit D

1.78 / 2.15

1.95 / 2.36

2.46 / 2.98

3.06 / 3.71

1.89 / 2.29

2.39 / 2.89

2.98 / 3.61

2.18 / 2.64

1.83 / 2.22

2.32 / 2.81

2.91 / 3.52

2.12 / 2.57

1.78 / 2.15

2.26 / 2.74

2.84 / 3.44

2.07 / 2.51

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 39

1 ROOM22

25

35

2 ROOMS22 + 22

22 + 25

22 + 35

25 + 25

25 + 35

35 + 35

Indoor unitcombination

Cooling / Heating Capacity (kW)

Unit A

2.20 / 3.30

2.50 / 3.60

3.50 / 4.00

2.20 / 3.05

2.20 / 2.90

1.93 / 2.43

2.50 / 3.15

2.13 / 2.63

2.60 / 3.20

Unit B

2.20 / 3.05

2.50 / 3.30

3.07 / 3.87

2.50 / 3.15

2.98 / 3.68

2.60 / 3.20

MXZ-2C52VA1Outdoor Unit 2 Indoor Units

MXZ-4C71VA1Outdoor Unit Up to 4 Indoor Units

1 ROOM22

25

35

50

60

2 ROOMS22 + 22

22 + 25

22 + 35

22 + 50

22 + 60

25 + 25

25 + 35

25 + 50

25 + 60

35 + 35

35 + 50

35 + 60

50 + 50

50 + 60

60 + 60

3 ROOMS22 + 22 + 22

22 + 22 + 25

22 + 22 + 35

22 + 22 + 50

22 + 22 + 60

22 + 25 + 25

22 + 25 + 35

22 + 25 + 50

22 + 25 + 60

22 + 35 + 35

22 + 35 + 50

22 + 35 + 60

22 + 50 + 50

25 + 25 + 25

25 + 25 + 35

25 + 25 + 50

25 + 25 + 60

25 + 35 + 35

25 + 35 + 50

25 + 35 + 60

25 + 50 + 50

35 + 35 + 35

35 + 35 + 50

Unit A

2.20 / 3.30

2.50 / 3.60

3.50 / 4.00

5.00 / 7.20

6.00 / 7.90

2.20 / 3.30

2.20 / 3.23

2.20 / 2.97

2.08 / 2.63

1.82 / 2.31

2.50 / 3.60

2.50 / 3.29

2.27 / 2.87

2.00 / 2.53

3.40 / 4.30

2.80 / 3.54

2.51 / 3.17

3.40 / 4.30

3.09 / 3.91

3.40 / 4.30

2.20 / 2.87

2.20 / 2.74

1.98 / 2.39

1.66 / 2.01

1.50 / 1.82

2.17 / 2.63

1.90 / 2.31

1.61 / 1.95

1.46 / 1.77

1.70 / 2.06

1.46 / 1.77

1.34 / 1.62

1.28 / 1.55

2.37 / 2.87

2.09 / 2.53

1.78 / 2.15

1.61 / 1.95

1.87 / 2.26

1.61 / 1.95

1.48 / 1.79

1.42 / 1.72

2.37 / 2.87

2.07 / 2.51

Unit B

2.20 / 3.30

2.50 / 3.67

3.50 / 4.73

4.72 / 5.97

4.98 / 6.29

2.50 / 3.60

3.50 / 4.61

4.53 / 5.73

4.80 / 6.07

3.40 / 4.30

4.00 / 5.06

4.29 / 5.43

3.40 / 4.30

3.71 / 4.69

3.40 / 4.30

2.20 / 2.87

2.20 / 2.74

1.98 / 2.39

1.66 / 2.01

1.50 / 1.82

2.47 / 2.99

2.16 / 2.62

1.83 / 2.22

1.66 / 2.01

2.70 / 3.27

2.32 / 2.81

2.12 / 2.57

2.91 / 3.52

2.37 / 2.87

2.09 / 2.53

1.78 / 2.15

1.61 / 1.95

2.62 / 3.17

2.26 / 2.74

2.07 / 2.51

2.84 / 3.44

2.37 / 2.87

2.07 / 2.51

Unit C

2.20 / 2.87

2.50 / 3.12

3.15 / 3.81

3.78 / 4.57

4.10 / 4.96

2.47 / 2.99

3.03 / 3.67

3.66 / 4.43

3.98 / 4.82

2.70 / 3.27

3.32 / 4.02

3.64 / 4.41

2.91 / 3.52

2.37 / 2.87

2.92 / 3.54

3.55 / 4.30

3.87 / 4.69

2.62 / 3.17

3.23 / 3.91

3.55 / 4.30

2.84 / 3.44

2.37 / 2.87

2.96 / 3.58

Unit D

Indoor unitcombination

Cooling / Heating Capacity (kW)

Multi-Split System Combinations

1 ROOM22

25

35

50

2 ROOMS22 + 22

22 + 25

22 + 35

22 + 50

25 + 25

25 + 35

25 + 50

35 + 35

35 + 50

50 + 50

3 ROOMS22 + 22 + 22

22 + 22 + 25

22 + 22 + 35

22 + 22 + 50

22 + 25 + 25

22 + 25 + 35

22 + 25 + 50

22 + 35 + 35

25 + 25 + 25

25 + 25 + 35

25 + 25 + 50

25 + 35 + 35

Indoor unitcombination

Cooling / Heating Capacity (kW)

Unit A

2.20 / 3.30

2.50 / 3.60

3.50 / 4.00

5.00 / 6.80

2.20 / 3.30

2.20 / 3.14

2.08 / 2.62

1.65 / 2.08

2.50 / 3.40

2.25 / 2.83

1.80 / 2.27

2.70 / 3.40

2.22 / 2.80

2.70 / 3.40

1.80 / 2.27

1.72 / 2.20

1.50 / 1.95

1.26 / 1.64

1.65 / 2.11

1.45 / 1.88

1.22 / 1.59

1.29 / 1.67

1.80 / 2.33

1.59 / 2.06

1.35 / 1.75

1.42 / 1.84

Unit B

2.20 / 3.30

2.50 / 3.56

3.32 / 4.18

3.75 / 4.72

2.50 / 3.40

3.15 / 3.97

3.60 / 4.53

2.70 / 3.40

3.18 / 4.00

2.70 / 3.40

1.80 / 2.27

1.72 / 2.20

1.50 / 1.95

1.26 / 1.64

1.88 / 2.40

1.65 / 2.13

1.39 / 1.80

2.05 / 2.66

1.80 / 2.33

1.59 / 2.06

1.35 / 1.75

1.99 / 2.58

Unit C

1.80 / 2.27

1.96 / 2.50

2.39 / 3.10

2.87 / 3.72

1.88 / 2.40

2.30 / 2.99

2.78 / 3.61

2.05 / 2.66

1.80 / 2.33

2.22 / 2.88

2.70 / 3.50

1.99 / 2.58

MXZ-3C54VA1Outdoor Unit Up to 3 Indoor Units

Page 38

Page 24: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

22 + 22 + 35 + 71

22 + 22 + 50 + 50

22 + 22 + 50 + 60

22 + 22 + 50 + 71

22 + 25 + 25 + 25

22 + 25 + 25 + 35

22 + 25 + 25 + 50

22 + 25 + 25 + 60

22 + 25 + 25 + 71

22 + 25 + 35 + 35

22 + 25 + 35 + 50

22 + 25 + 35 + 60

22 + 25 + 35 + 71

22 + 25 + 50 + 50

22 + 25 + 50 + 60

22 + 25 + 50 + 71

22 + 35 + 35 + 35

22 + 35 + 35 + 50

22 + 35 + 35 + 60

22 + 35 + 35 + 71

22 + 35 + 50 + 50

22 + 35 + 50 + 60

25 + 25 + 25 + 25

25 + 25 + 25 + 35

25 + 25 + 25 + 50

25 + 25 + 25 + 60

25 + 25 + 25 + 71

25 + 25 + 35 + 35

25 + 25 + 35 + 50

25 + 25 + 35 + 60

25 + 25 + 35 + 71

25 + 25 + 50 + 50

25 + 25 + 50 + 60

25 + 25 + 50 + 71

25 + 35 + 35 + 35

25 + 35 + 35 + 50

25 + 35 + 35 + 60

25 + 35 + 35 + 71

35 + 35 + 35 + 35

35 + 35 + 35 + 50

35 + 35 + 35 + 60

Unit A

1.39 / 1.61

1.45 / 1.68

1.37 / 1.57

1.31 / 1.47

1.93 / 2.27

1.79 / 2.10

1.62 / 1.91

1.53 / 1.80

1.45 / 1.69

1.67 / 1.96

1.53 / 1.80

1.46 / 1.70

1.38 / 1.58

1.42 / 1.65

1.35 / 1.54

1.28 / 1.44

1.58 / 1.85

1.46 / 1.70

1.39 / 1.59

1.31 / 1.48

1.35 / 1.54

1.29 / 1.45

2.15 / 2.50

2.00 / 2.34

1.82 / 2.12

1.72 / 2.02

1.63 / 1.88

1.88 / 2.19

1.72 / 2.02

1.64 / 1.90

1.54 / 1.76

1.58 / 1.83

1.52 / 1.72

1.43 / 1.61

1.77 / 2.08

1.64 / 1.90

1.55 / 1.77

1.48 / 1.66

2.35 / 2.75

2.17 / 2.48

2.08 / 2.33

Unit B

1.39 / 1.61

1.45 / 1.68

1.37 / 1.57

1.31 / 1.47

2.19 / 2.58

2.03 / 2.38

1.84 / 2.17

1.74 / 2.05

1.64 / 1.92

1.90 / 2.22

1.74 / 2.05

1.65 / 1.94

1.57 / 1.80

1.62 / 1.87

1.53 / 1.75

1.46 / 1.64

2.51 / 2.95

2.32 / 2.71

2.21 / 2.53

2.08 / 2.36

2.14 / 2.45

2.05 / 2.31

2.15 / 2.50

2.00 / 2.34

1.82 / 2.12

1.72 / 2.02

1.63 / 1.88

1.88 / 2.19

1.72 / 2.02

1.64 / 1.90

1.54 / 1.76

1.58 / 1.83

1.52 / 1.72

1.43 / 1.61

2.48 / 2.91

2.29 / 2.66

2.17 / 2.48

2.07 / 2.32

2.35 / 2.75

2.17 / 2.48

2.08 / 2.33

Unit C

2.22 / 2.57

3.30 / 3.82

3.12 / 3.57

2.97 / 3.33

2.19 / 2.58

2.03 / 2.38

1.84 / 2.17

1.74 / 2.05

1.64 / 1.92

2.66 / 3.11

2.44 / 2.86

2.32 / 2.71

2.20 / 2.52

3.23 / 3.74

3.06 / 3.50

2.92 / 3.27

2.51 / 2.95

2.32 / 2.71

2.21 / 2.53

2.08 / 2.36

3.06 / 3.50

2.93 / 3.29

2.15 / 2.50

2.00 / 2.34

1.82 / 2.12

1.72 / 2.02

1.63 / 1.88

2.63 / 3.06

2.41 / 2.83

2.29 / 2.66

2.15 / 2.47

3.17 / 3.67

3.03 / 3.44

2.87 / 3.22

2.48 / 2.91

2.29 / 2.66

2.17 / 2.48

2.07 / 2.32

2.35 / 2.75

2.17 / 2.48

2.08 / 2.33

Unit D

4.50 / 5.21

3.30 / 3.82

3.74 / 4.29

4.22 / 4.73

2.19 / 2.58

2.85 / 3.34

3.69 / 4.34

4.18 / 4.91

4.67 / 5.46

2.66 / 3.11

3.48 / 4.09

3.97 / 4.65

4.45 / 5.10

3.23 / 3.74

3.67 / 4.20

4.14 / 4.65

2.51 / 2.95

3.31 / 3.87

3.79 / 4.34

4.23 / 4.79

3.06 / 3.50

3.52 / 3.95

2.15 / 2.50

2.80 / 3.28

3.64 / 4.24

4.13 / 4.84

4.62 / 5.35

2.63 / 3.06

3.44 / 4.04

3.93 / 4.54

4.37 / 5.01

3.17 / 3.67

3.64 / 4.13

4.07 / 4.57

2.48 / 2.91

3.28 / 3.79

3.72 / 4.26

4.19 / 4.70

2.35 / 2.75

3.10 / 3.55

3.56 / 4.00

Indoor unitcombination

Cooling / Heating Capacity (kW)

25 + 25 + 25

25 + 25 + 35

25 + 25 + 50

25 + 25 + 60

25 + 25 + 71

25 + 35 + 35

25 + 35 + 50

25 + 35 + 60

25 + 35 + 71

25 + 50 + 50

25 + 50 + 60

25 + 50 + 71

25 + 60 + 60

25 + 60 + 71

35 + 35 + 35

35 + 35 + 50

35 + 35 + 60

35 + 35 + 71

35 + 50 + 50

35 + 50 + 60

35 + 50 + 71

35 + 60 + 60

35 + 60 + 71

50 + 50 + 50

50 + 50 + 60

50 + 50 + 71

4 ROOMS

22 + 22 + 22 + 22

22 + 22 + 22 + 25

22 + 22 + 22 + 35

22 + 22 + 22 + 50

22 + 22 + 22 + 60

22 + 22 + 22 + 71

22 + 22 + 25 + 25

22 + 22 + 25 + 35

22 + 22 + 25 + 50

22 + 22 + 25 + 60

22 + 22 + 25 + 71

22 + 22 + 35 + 35

22 + 22 + 35 + 50

22 + 22 + 35 + 60

Unit A

2.50 / 3.00

2.32 / 2.74

2.10 / 2.45

1.98 / 2.32

1.84 / 2.19

2.16 / 2.55

1.98 / 2.32

1.85 / 2.21

1.74 / 2.06

1.80 / 2.16

1.70 / 2.02

1.59 / 1.88

1.60 / 1.90

1.51 / 1.76

2.87 / 3.33

2.60 / 3.09

2.45 / 2.91

2.31 / 2.71

2.39 / 2.83

2.24 / 2.66

2.11 / 2.47

2.12 / 2.48

1.98 / 2.32

3.13 / 3.67

2.94 / 3.44

2.75 / 3.22

2.00 / 2.50

1.98 / 2.42

1.87 / 2.18

1.69 / 1.97

1.59 / 1.87

1.49 / 1.75

1.94 / 2.34

1.84 / 2.14

1.66 / 1.94

1.57 / 1.82

1.48 / 1.73

1.72 / 2.01

1.57 / 1.82

1.49 / 1.74

Unit B

2.50 / 3.00

2.32 / 2.74

2.10 / 2.45

1.98 / 2.32

1.84 / 2.19

3.02 / 3.57

2.77 / 3.25

2.60 / 3.09

2.43 / 2.89

3.60 / 4.32

3.41 / 4.04

3.18 / 3.77

3.85 / 4.55

3.62 / 4.23

2.87 / 3.33

2.60 / 3.09

2.45 / 2.91

2.31 / 2.71

3.41 / 4.04

3.21 / 3.79

3.01 / 3.53

3.64 / 4.26

3.40 / 3.98

3.13 / 3.67

2.94 / 3.44

2.75 / 3.22

2.00 / 2.50

1.98 / 2.42

1.87 / 2.18

1.69 / 1.97

1.59 / 1.87

1.49 / 1.75

1.94 / 2.34

1.84 / 2.14

1.66 / 1.94

1.57 / 1.82

1.48 / 1.73

1.72 / 2.01

1.57 / 1.82

1.49 / 1.74

Unit C

2.50 / 3.00

3.25 / 3.83

4.20 / 4.90

4.75 / 5.56

5.22 / 6.22

3.02 / 3.57

3.95 / 4.64

4.45 / 5.30

4.93 / 5.85

3.60 / 4.32

4.09 / 4.84

4.52 / 5.35

3.85 / 4.55

4.28 / 5.01

2.87 / 3.33

3.71 / 4.42

4.20 / 4.98

4.68 / 5.49

3.41 / 4.04

3.85 / 4.55

4.28 / 5.01

3.64 / 4.26

4.02 / 4.70

3.13 / 3.67

3.53 / 4.13

3.90 / 4.57

2.00 / 2.50

1.98 / 2.42

1.87 / 2.18

1.69 / 1.97

1.59 / 1.87

1.49 / 1.75

2.21 / 2.66

2.09 / 2.43

1.89 / 2.21

1.78 / 2.07

1.68 / 1.96

2.73 / 3.19

2.50 / 2.90

2.37 / 2.77

Unit D

2.00 / 2.50

2.25 / 2.75

2.98 / 3.47

3.84 / 4.48

4.33 / 5.10

4.82 / 5.65

2.21 / 2.66

2.93 / 3.40

3.78 / 4.41

4.28 / 4.98

4.77 / 5.58

2.73 / 3.19

3.57 / 4.15

4.06 / 4.75

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 41

4 ROOMS22 + 22 + 22 + 22

22 + 22 + 22 + 25

22 + 22 + 22 + 35

22 + 22 + 22 + 50

22 + 22 + 22 + 60

22 + 22 + 22 + 71

22 + 22 + 25 + 25

22 + 22 + 25 + 35

22 + 22 + 25 + 50

22 + 22 + 25 + 60

22 + 22 + 25 + 71

22 + 22 + 35 + 35

22 + 22 + 35 + 50

22 + 22 + 35 + 60

22 + 22 + 50 + 50

22 + 25 + 25 + 25

22 + 25 + 25 + 35

22 + 25 + 25 + 50

22 + 25 + 25 + 60

22 + 25 + 35 + 35

22 + 25 + 35 + 50

22 + 25 + 35 + 60

22 + 35 + 35 + 35

22 + 35 + 35 + 50

25 + 25 + 25 + 25

25 + 25 + 25 + 35

25 + 25 + 25 + 50

25 + 25 + 25 + 60

25 + 25 + 35 + 35

25 + 25 + 35 + 50

25 + 35 + 35 + 35

35 + 35 + 35 + 35

Unit A

1.95 / 2.35

1.90 / 2.27

1.73 / 2.05

1.52 / 1.78

1.40 / 1.64

1.28 / 1.51

1.84 / 2.20

1.68 / 1.99

1.48 / 1.74

1.36 / 1.60

1.26 / 1.48

1.54 / 1.81

1.36 / 1.60

1.27 / 1.49

1.22 / 1.44

1.79 / 2.13

1.63 / 1.93

1.44 / 1.70

1.33 / 1.57

1.50 / 1.77

1.33 / 1.57

1.24 / 1.46

1.39 / 1.63

1.24 / 1.45

1.98 / 2.35

1.82 / 2.14

1.60 / 1.88

1.48 / 1.74

1.67 / 1.96

1.48 / 1.74

1.54 / 1.81

2.00 / 2.35

Unit B

1.95 / 2.35

1.90 / 2.27

1.73 / 2.05

1.52 / 1.78

1.40 / 1.64

1.28 / 1.51

1.84 / 2.20

1.68 / 1.99

1.48 / 1.74

1.36 / 1.60

1.26 / 1.48

1.54 / 1.81

1.36 / 1.60

1.27 / 1.49

1.22 / 1.44

2.04 / 2.42

1.86 / 2.20

1.64 / 1.93

1.52 / 1.78

1.71 / 2.01

1.52 / 1.78

1.41 / 1.65

2.20 / 2.59

1.97 / 2.32

1.98 / 2.35

1.82 / 2.14

1.60 / 1.88

1.48 / 1.74

1.67 / 1.96

1.48 / 1.74

2.15 / 2.53

2.00 / 2.35

Unit C

1.95 / 2.35

1.90 / 2.27

1.73 / 2.05

1.52 / 1.78

1.40 / 1.64

1.28 / 1.51

2.09 / 2.50

1.91 / 2.26

1.68 / 1.97

1.55 / 1.82

1.43 / 1.68

2.46 / 2.89

2.17 / 2.55

2.01 / 2.37

2.78 / 3.26

2.04 / 2.42

1.86 / 2.20

1.64 / 1.93

1.52 / 1.78

2.39 / 2.81

2.12 / 2.49

1.97 / 2.32

2.20 / 2.59

1.97 / 2.32

1.98 / 2.35

1.82 / 2.14

1.60 / 1.88

1.48 / 1.74

2.33 / 2.74

2.07 / 2.44

2.15 / 2.53

2.00 / 2.35

Unit D

1.95 / 2.35

2.16 / 2.58

2.75 / 3.26

3.45 / 4.05

3.81 / 4.48

4.15 / 4.87

2.09 / 2.50

2.68 / 3.16

3.36 / 3.95

3.72 / 4.37

4.06 / 4.77

2.46 / 2.89

3.10 / 3.64

3.45 / 4.06

2.78 / 3.26

2.04 / 2.42

2.60 / 3.07

3.28 / 3.85

3.64 / 4.27

2.39 / 2.81

3.03 / 3.56

3.38 / 3.97

2.20 / 2.59

2.82 / 3.31

1.98 / 2.35

2.55 / 2.99

3.20 / 3.76

3.56 / 4.18

2.33 / 2.74

2.96 / 3.48

2.15 / 2.53

2.00 / 2.35

Indoor unitcombination

Cooling / Heating Capacity (kW)

1 ROOM22

25

35

50

60

71

Unit A

2.20 / 3.30

2.50 / 3.60

3.50 / 4.00

5.00 / 7.20

6.00 / 7.90

7.10 / 8.60

Unit B Unit C Unit D

Indoor unitcombination

Cooling / Heating Capacity (kW)

MXZ-5C100VA1Outdoor Unit Up to 5 Indoor Units

2 ROOMS22 + 22

22 + 25

22 + 35

22 + 50

22 + 60

22 + 71

25 + 25

25 + 35

25 + 50

25 + 60

25 + 71

35 + 35

35 + 50

35 + 60

35 + 71

50 + 50

50 + 60

50 + 71

60 + 60

60 + 71

71 + 71

3 ROOMS

22 + 22 + 22

22 + 22 + 25

22 + 22 + 35

22 + 22 + 50

22 + 22 + 60

22 + 22 + 71

22 + 25 + 25

22 + 25 + 35

22 + 25 + 50

22 + 25 + 60

22 + 25 + 71

22 + 35 + 35

22 + 35 + 50

22 + 35 + 60

22 + 35 + 71

22 + 50 + 50

22 + 50 + 60

22 + 50 + 71

22 + 60 + 60

22 + 60 + 71

Unit A

2.20 / 3.30

2.20 / 3.23

2.20 / 2.89

2.17 / 2.57

2.07 / 2.71

1.92 / 2.51

2.50 / 3.60

2.50 / 3.17

2.43 / 2.97

2.29 / 3.09

2.14 / 2.76

3.50 / 4.00

3.21 / 4.32

2.98 / 3.91

2.81 / 3.50

4.15 / 5.30

3.91 / 4.82

3.68 / 4.38

4.45 / 5.30

4.12 / 4.85

4.55 / 5.30

2.20 / 2.90

2.20 / 2.81

2.12 / 2.53

1.92 / 2.25

1.82 / 2.12

1.68 / 1.99

2.20 / 2.72

2.09 / 2.47

1.88 / 2.20

1.77 / 2.08

1.64 / 1.96

1.94 / 2.30

1.77 / 2.08

1.65 / 1.97

1.55 / 1.86

1.60 / 1.91

1.52 / 1.82

1.43 / 1.68

1.44 / 1.69

1.35 / 1.58

Unit B

2.20 / 3.30

2.50 / 3.67

3.50 / 4.61

4.93 / 5.83

5.63 / 7.39

6.18 / 8.09

2.50 / 3.60

3.50 / 4.43

4.87 / 5.93

5.51 / 7.41

6.06 / 7.84

3.50 / 4.00

4.59 / 6.18

5.12 / 6.69

5.69 / 7.10

4.15 / 5.30

4.69 / 5.78

5.22 / 6.22

4.45 / 5.30

4.88 / 5.75

4.55 / 5.30

2.20 / 2.90

2.20 / 2.81

2.12 / 2.53

1.92 / 2.25

1.82 / 2.12

1.68 / 1.99

2.50 / 3.09

2.38 / 2.80

2.14 / 2.50

2.01 / 2.36

1.86 / 2.22

3.08 / 3.65

2.81 / 3.30

2.63 / 3.14

2.46 / 2.95

3.65 / 4.34

3.45 / 4.13

3.25 / 3.81

3.93 / 4.61

3.69 / 4.31

Unit C

2.20 / 2.90

2.50 / 3.19

3.37 / 4.03

4.36 / 5.11

4.96 / 5.77

5.43 / 6.42

2.50 / 3.09

3.33 / 3.93

4.28 / 5.00

4.82 / 5.66

5.29 / 6.32

3.08 / 3.65

4.02 / 4.72

4.51 / 5.38

4.99 / 5.99

3.65 / 4.34

4.14 / 4.95

4.62 / 5.41

3.93 / 4.61

4.36 / 5.10

Unit D

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 40

Page 25: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

1 ROOM

22

25

35

50

60

71

2 ROOMS

22 + 22

22 + 25

22 + 35

22 + 50

22 + 60

22 + 71

25 + 25

25 + 35

25 + 50

25 + 60

25 + 71

35 + 35

35 + 50

35 + 60

35 + 71

50 + 50

50 + 60

50 + 71

60 + 60

60 + 71

71 + 71

3 ROOMS

22 + 22 + 22

22 + 22 + 25

22 + 22 + 35

22 + 22 + 50

22 + 22 + 60

22 + 22 + 71

22 + 25 + 25

22 + 25 + 35

Unit A

2.20 / 3.30

2.50 / 3.60

3.50 / 4.00

5.00 / 7.20

6.00 / 7.90

7.10 / 8.60

2.20 / 3.30

2.20 / 3.23

2.20 / 2.89

2.20 / 2.57

2.20 / 2.79

2.06 / 2.63

2.50 / 3.60

2.50 / 3.17

2.50 / 3.00

2.47 / 3.18

2.29 / 2.92

3.50 / 4.00

3.46 / 4.45

3.21 / 4.09

3.00 / 3.73

4.45 / 5.65

4.23 / 5.14

3.97 / 4.67

4.80 / 5.65

4.44 / 5.18

4.85 / 5.65

2.20 / 3.30

2.20 / 3.25

2.09 / 3.06

2.08 / 2.71

2.03 / 2.54

1.86 / 2.35

2.20 / 3.21

2.20 / 2.98

Unit B

2.20 / 3.30

2.50 / 3.67

3.50 / 4.61

5.00 / 5.83

6.00 / 7.61

6.64 / 8.47

2.50 / 3.60

3.50 / 4.43

5.00 / 6.00

5.93 / 7.62

6.51 / 8.28

3.50 / 4.00

4.94 / 6.35

5.49 / 7.01

6.10 / 7.57

4.45 / 5.65

5.07 / 6.16

5.63 / 6.63

4.80 / 5.65

5.26 / 6.12

4.85 / 5.65

2.20 / 3.30

2.20 / 3.25

2.09 / 3.06

2.08 / 2.71

2.03 / 2.54

1.86 / 2.35

2.50 / 3.65

2.50 / 3.38

Unit C

2.20 / 3.30

2.50 / 3.70

3.32 / 4.87

4.73 / 6.17

5.54 / 6.92

5.99 / 7.59

2.50 / 3.65

3.50 / 4.74

Unit D

Indoor unitcombination

Cooling / Heating Capacity (kW)

MXZ-6C120VA1Outdoor Unit Up to 6 Indoor Units

22 + 25 + 50

22 + 25 + 60

22 + 25 + 71

22 + 35 + 35

22 + 35 + 50

22 + 35 + 60

22 + 35 + 71

22 + 50 + 50

22 + 50 + 60

22 + 50 + 71

22 + 60 + 60

22 + 60 + 71

22 + 71 + 71

25 + 25 + 25

25 + 25 + 35

25 + 25 + 50

25 + 25 + 60

25 + 25 + 71

25 + 35 + 35

25 + 35 + 50

25 + 35 + 60

25 + 35 + 71

25 + 50 + 50

25 + 50 + 60

25 + 50 + 71

25 + 60 + 60

25 + 60 + 71

25 + 71 + 71

35 + 35 + 35

35 + 35 + 50

35 + 35 + 60

35 + 35 + 71

35 + 50 + 50

35 + 50 + 60

35 + 50 + 71

35 + 60 + 60

35 + 60 + 71

35 + 71 + 71

50 + 50 + 50

50 + 50 + 60

50 + 50 + 71

50 + 60 + 60

60 + 60 + 60

Unit A

2.02 / 2.65

1.97 / 2.49

1.83 / 2.31

2.13 / 2.75

1.97 / 2.49

1.84 / 2.31

1.72 / 2.17

1.77 / 2.25

1.68 / 2.12

1.60 / 2.00

1.61 / 2.00

1.54 / 1.90

1.48 / 1.78

2.50 / 3.60

2.41 / 3.29

2.40 / 2.95

2.20 / 2.75

2.02 / 2.58

2.34 / 3.05

2.20 / 2.75

2.04 / 2.58

1.91 / 2.42

1.98 / 2.52

1.89 / 2.37

1.80 / 2.23

1.81 / 2.24

1.73 / 2.12

1.66 / 2.01

3.20 / 4.00

2.86 / 3.62

2.69 / 3.42

2.56 / 3.20

2.64 / 3.32

2.53 / 3.14

2.42 / 2.96

2.44 / 2.98

2.34 / 2.83

2.25 / 2.69

3.53 / 4.37

3.41 / 4.16

3.27 / 3.95

3.29 / 3.94

3.83 / 4.53

Unit B

2.29 / 3.02

2.24 / 2.83

2.08 / 2.63

3.39 / 4.38

3.14 / 3.96

2.93 / 3.68

2.73 / 3.45

4.02 / 5.12

3.83 / 4.81

3.64 / 4.55

4.39 / 5.45

4.20 / 5.18

4.76 / 5.76

2.50 / 3.60

2.41 / 3.29

2.40 / 2.95

2.20 / 2.75

2.02 / 2.58

3.28 / 4.27

3.09 / 3.85

2.86 / 3.62

2.67 / 3.39

3.96 / 5.04

3.78 / 4.74

3.60 / 4.45

4.34 / 5.38

4.15 / 5.08

4.72 / 5.70

3.20 / 4.00

2.86 / 3.62

2.69 / 3.42

2.56 / 3.20

3.78 / 4.74

3.62 / 4.48

3.46 / 4.23

4.18 / 5.11

4.01 / 4.84

4.57 / 5.46

3.53 / 4.37

3.41 / 4.16

3.27 / 3.95

3.95 / 4.73

3.83 / 4.53

Unit C

4.59 / 6.03

5.38 / 6.79

5.90 / 7.46

3.39 / 4.38

4.49 / 5.65

5.03 / 6.31

5.55 / 6.99

4.02 / 5.12

4.59 / 5.77

5.16 / 6.45

4.39 / 5.45

4.97 / 6.13

4.76 / 5.76

2.50 / 3.60

3.38 / 4.61

4.80 / 5.90

5.29 / 6.60

5.75 / 7.33

3.28 / 4.27

4.41 / 5.50

4.90 / 6.20

5.42 / 6.88

3.96 / 5.04

4.53 / 5.69

5.11 / 6.32

4.34 / 5.38

4.92 / 6.01

4.72 / 5.70

3.20 / 4.00

4.08 / 5.17

4.62 / 5.86

5.19 / 6.50

3.78 / 4.74

4.34 / 5.38

4.92 / 6.01

4.18 / 5.11

4.75 / 5.73

4.57 / 5.46

3.53 / 4.37

4.09 / 4.99

4.65 / 5.61

3.95 / 4.73

3.83 / 4.53

Unit D

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 43

5 ROOMS22 + 22 + 22 + 22 + 22

22 + 22 + 22 + 22 + 25

22 + 22 + 22 + 22 + 35

22 + 22 + 22 + 22 + 50

22 + 22 + 22 + 22 + 60

22 + 22 + 22 + 22 + 71

22 + 22 + 22 + 25 + 25

22 + 22 + 22 + 25 + 35

22 + 22 + 22 + 25 + 50

22 + 22 + 22 + 25 + 60

22 + 22 + 22 + 25 + 71

22 + 22 + 22 + 35 + 35

22 + 22 + 22 + 35 + 50

22 + 22 + 22 + 35 + 60

22 + 22 + 22 + 35 + 71

22 + 22 + 25 + 25 + 25

22 + 22 + 25 + 25 + 35

22 + 22 + 25 + 25 + 50

22 + 22 + 25 + 25 + 60

22 + 22 + 25 + 25 + 71

22 + 22 + 25 + 35 + 35

22 + 22 + 25 + 35 + 50

22 + 22 + 25 + 35 + 60

22 + 22 + 35 + 35 + 35

22 + 22 + 35 + 35 + 50

22 + 25 + 25 + 25 + 25

22 + 25 + 25 + 25 + 35

22 + 25 + 25 + 25 + 50

22 + 25 + 25 + 25 + 60

22 + 25 + 25 + 25 + 71

22 + 25 + 25 + 35 + 35

22 + 25 + 25 + 35 + 50

22 + 25 + 25 + 35 + 60

22 + 25 + 35 + 35 + 35

22 + 25 + 35 + 35 + 50

22 + 35 + 35 + 35 + 35

25 + 25 + 25 + 25 + 25

25 + 25 + 25 + 25 + 35

25 + 25 + 25 + 25 + 50

25 + 25 + 25 + 25 + 60

25 + 25 + 25 + 25 + 71

25 + 25 + 25 + 35 + 35

25 + 25 + 25 + 35 + 50

25 + 25 + 25 + 35 + 60

25 + 25 + 35 + 35 + 35

25 + 25 + 35 + 35 + 50

Unit A

2.00 / 2.40

1.95 / 2.34

1.79 / 2.15

1.59 / 1.91

1.49 / 1.78

1.38 / 1.66

1.90 / 2.28

1.75 / 2.10

1.56 / 1.87

1.46 / 1.75

1.36 / 1.63

1.62 / 1.94

1.46 / 1.75

1.37 / 1.64

1.28 / 1.53

1.85 / 2.22

1.71 / 2.05

1.53 / 1.83

1.43 / 1.71

1.33 / 1.60

1.58 / 1.90

1.43 / 1.71

1.34 / 1.61

1.48 / 1.77

1.34 / 1.61

1.80 / 2.16

1.67 / 2.00

1.50 / 1.80

1.40 / 1.68

1.31 / 1.57

1.55 / 1.86

1.40 / 1.68

1.32 / 1.58

1.45 / 1.74

1.32 / 1.58

1.36 / 1.63

2.00 / 2.40

1.85 / 2.22

1.67 / 2.00

1.56 / 1.88

1.46 / 1.75

1.72 / 2.07

1.56 / 1.88

1.47 / 1.76

1.61 / 1.94

1.47 / 1.76

Unit B

2.00 / 2.40

1.95 / 2.34

1.79 / 2.15

1.59 / 1.91

1.49 / 1.78

1.38 / 1.66

1.90 / 2.28

1.75 / 2.10

1.56 / 1.87

1.46 / 1.75

1.36 / 1.63

1.62 / 1.94

1.46 / 1.75

1.37 / 1.64

1.28 / 1.53

1.85 / 2.22

1.71 / 2.05

1.53 / 1.83

1.43 / 1.71

1.33 / 1.60

1.58 / 1.90

1.43 / 1.71

1.34 / 1.61

1.48 / 1.77

1.34 / 1.61

2.05 / 2.46

1.89 / 2.27

1.70 / 2.04

1.59 / 1.91

1.49 / 1.79

1.76 / 2.11

1.59 / 1.91

1.50 / 1.80

1.64 / 1.97

1.50 / 1.80

2.16 / 2.59

2.00 / 2.40

1.85 / 2.22

1.67 / 2.00

1.56 / 1.88

1.46 / 1.75

1.72 / 2.07

1.56 / 1.88

1.47 / 1.76

1.61 / 1.94

1.47 / 1.76

Unit C

2.00 / 2.40

1.95 / 2.34

1.79 / 2.15

1.59 / 1.91

1.49 / 1.78

1.38 / 1.66

1.90 / 2.28

1.75 / 2.10

1.56 / 1.87

1.46 / 1.75

1.36 / 1.63

1.62 / 1.94

1.46 / 1.75

1.37 / 1.64

1.28 / 1.53

2.10 / 2.52

1.94 / 2.33

1.74 / 2.08

1.62 / 1.95

1.52 / 1.82

1.80 / 2.16

1.62 / 1.95

1.52 / 1.83

2.35 / 2.82

2.13 / 2.56

2.05 / 2.46

1.89 / 2.27

1.70 / 2.04

1.59 / 1.91

1.49 / 1.79

1.76 / 2.11

1.59 / 1.91

1.50 / 1.80

2.30 / 2.76

2.10 / 2.51

2.16 / 2.59

2.00 / 2.40

1.85 / 2.22

1.67 / 2.00

1.56 / 1.88

1.46 / 1.75

1.72 / 2.07

1.56 / 1.88

1.47 / 1.76

2.26 / 2.71

2.06 / 2.47

Unit D

2.00 / 2.40

1.95 / 2.34

1.79 / 2.15

1.59 / 1.91

1.49 / 1.78

1.38 / 1.66

2.16 / 2.59

1.98 / 2.38

1.77 / 2.13

1.66 / 1.99

1.54 / 1.85

2.57 / 3.09

2.32 / 2.78

2.17 / 2.61

2.03 / 2.44

2.10 / 2.52

1.94 / 2.33

1.74 / 2.08

1.62 / 1.95

1.52 / 1.82

2.52 / 3.02

2.27 / 2.73

2.13 / 2.56

2.35 / 2.82

2.13 / 2.56

2.05 / 2.46

1.89 / 2.27

1.70 / 2.04

1.59 / 1.91

1.49 / 1.79

2.46 / 2.96

2.23 / 2.68

2.10 / 2.51

2.30 / 2.76

2.10 / 2.51

2.16 / 2.59

2.00 / 2.40

1.85 / 2.22

1.67 / 2.00

1.56 / 1.88

1.46 / 1.75

2.41 / 2.90

2.19 / 2.63

2.06 / 2.47

2.26 / 2.71

2.06 / 2.47

Unit E

2.00 / 2.40

2.21 / 2.65

2.85 / 3.41

3.62 / 4.35

4.05 / 4.86

4.47 / 5.36

2.16 / 2.59

2.78 / 3.33

3.55 / 4.26

3.97 / 4.77

4.38 / 5.26

2.57 / 3.09

3.31 / 3.97

3.73 / 4.47

4.13 / 4.95

2.10 / 2.52

2.71 / 3.26

3.47 / 4.17

3.90 / 4.68

4.30 / 5.16

2.52 / 3.02

3.25 / 3.90

3.66 / 4.39

2.35 / 2.82

3.05 / 3.66

2.05 / 2.46

2.65 / 3.18

3.40 / 4.08

3.82 / 4.59

4.23 / 5.07

2.46 / 2.96

3.18 / 3.82

3.59 / 4.31

2.30 / 2.76

2.99 / 3.59

2.16 / 2.59

2.00 / 2.40

2.59 / 3.11

3.33 / 4.00

3.75 / 4.50

4.15 / 4.98

2.41 / 2.90

3.13 / 3.75

3.53 / 4.24

2.26 / 2.71

2.94 / 3.53

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 42

Page 26: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

5 ROOMS22 + 22 + 22 + 22 + 22

22 + 22 + 22 + 22 + 25

22 + 22 + 22 + 22 + 35

22 + 22 + 22 + 22 + 50

22 + 22 + 22 + 22 + 60

22 + 22 + 22 + 22 + 71

22 + 22 + 22 + 25 + 25

22 + 22 + 22 + 25 + 35

22 + 22 + 22 + 25 + 50

22 + 22 + 22 + 25 + 60

22 + 22 + 22 + 25 + 71

22 + 22 + 22 + 35 + 35

22 + 22 + 22 + 35 + 50

22 + 22 + 22 + 35 + 60

22 + 22 + 22 + 35 + 71

22 + 22 + 22 + 50 + 50

22 + 22 + 22 + 50 + 60

22 + 22 + 25 + 25 + 25

22 + 22 + 25 + 25 + 35

22 + 22 + 25 + 25 + 50

22 + 22 + 25 + 25 + 60

22 + 22 + 25 + 25 + 71

22 + 22 + 25 + 35 + 35

22 + 22 + 25 + 35 + 50

22 + 22 + 25 + 35 + 60

22 + 22 + 25 + 35 + 71

22 + 22 + 25 + 50 + 50

22 + 22 + 25 + 50 + 60

22 + 22 + 35 + 35 + 35

22 + 22 + 35 + 35 + 50

22 + 22 + 35 + 35 + 60

22 + 22 + 35 + 50 + 50

22 + 25 + 25 + 25 + 25

22 + 25 + 25 + 25 + 35

22 + 25 + 25 + 25 + 50

22 + 25 + 25 + 25 + 60

22 + 25 + 25 + 25 + 71

22 + 25 + 25 + 35 + 35

22 + 25 + 25 + 35 + 50

22 + 25 + 25 + 35 + 60

22 + 25 + 25 + 35 + 71

22 + 25 + 25 + 50 + 50

22 + 25 + 35 + 35 + 35

22 + 25 + 35 + 35 + 50

22 + 25 + 35 + 35 + 60

22 + 35 + 35 + 35 + 35

22 + 35 + 35 + 35 + 50

25 + 25 + 25 + 25 + 25

25 + 25 + 25 + 25 + 35

25 + 25 + 25 + 25 + 50

25 + 25 + 25 + 25 + 60

25 + 25 + 25 + 25 + 71

25 + 25 + 25 + 35 + 35

Unit A

2.20 / 2.62

2.18 / 2.57

2.11 / 2.40

1.91 / 2.14

1.78 / 1.99

1.67 / 1.85

2.16 / 2.50

2.08 / 2.34

1.87 / 2.09

1.76 / 1.95

1.64 / 1.82

1.94 / 2.17

1.76 / 1.95

1.65 / 1.83

1.56 / 1.71

1.60 / 1.78

1.53 / 1.68

2.13 / 2.46

2.03 / 2.29

1.83 / 2.05

1.73 / 1.91

1.61 / 1.79

1.90 / 2.12

1.73 / 1.91

1.62 / 1.80

1.53 / 1.68

1.59 / 1.74

1.50 / 1.65

1.77 / 1.98

1.62 / 1.80

1.54 / 1.69

1.50 / 1.65

2.11 / 2.40

1.98 / 2.23

1.80 / 2.01

1.70 / 1.88

1.60 / 1.75

1.86 / 2.08

1.70 / 1.88

1.61 / 1.77

1.51 / 1.66

1.56 / 1.71

1.75 / 1.94

1.61 / 1.77

1.52 / 1.67

1.64 / 1.82

1.52 / 1.67

2.38 / 2.68

2.22 / 2.48

2.02 / 2.23

1.89 / 2.09

1.78 / 1.96

2.07 / 2.31

Unit B

2.20 / 2.62

2.18 / 2.57

2.11 / 2.40

1.91 / 2.14

1.78 / 1.99

1.67 / 1.85

2.16 / 2.50

2.08 / 2.34

1.87 / 2.09

1.76 / 1.95

1.64 / 1.82

1.94 / 2.17

1.76 / 1.95

1.65 / 1.83

1.56 / 1.71

1.60 / 1.78

1.53 / 1.68

2.13 / 2.46

2.03 / 2.29

1.83 / 2.05

1.73 / 1.91

1.61 / 1.79

1.90 / 2.12

1.73 / 1.91

1.62 / 1.80

1.53 / 1.68

1.59 / 1.74

1.50 / 1.65

1.77 / 1.98

1.62 / 1.80

1.54 / 1.69

1.50 / 1.65

2.40 / 2.73

2.25 / 2.54

2.04 / 2.28

1.93 / 2.13

1.82 / 1.99

2.11 / 2.36

1.93 / 2.13

1.83 / 2.01

1.71 / 1.88

1.77 / 1.95

1.99 / 2.20

1.83 / 2.01

1.72 / 1.89

2.61 / 2.90

2.41 / 2.65

2.38 / 2.68

2.22 / 2.48

2.02 / 2.23

1.89 / 2.09

1.78 / 1.96

2.07 / 2.31

Unit C

2.20 / 2.62

2.18 / 2.57

2.11 / 2.40

1.91 / 2.14

1.78 / 1.99

1.67 / 1.85

2.16 / 2.50

2.08 / 2.34

1.87 / 2.09

1.76 / 1.95

1.64 / 1.82

1.94 / 2.17

1.76 / 1.95

1.65 / 1.83

1.56 / 1.71

1.60 / 1.78

1.53 / 1.68

2.42 / 2.79

2.31 / 2.60

2.08 / 2.33

1.96 / 2.18

1.83 / 2.03

2.16 / 2.41

1.96 / 2.18

1.84 / 2.04

1.74 / 1.91

1.80 / 1.98

1.70 / 1.87

2.82 / 3.15

2.58 / 2.86

2.45 / 2.70

2.39 / 2.62

2.40 / 2.73

2.25 / 2.54

2.04 / 2.28

1.93 / 2.13

1.82 / 1.99

2.11 / 2.36

1.93 / 2.13

1.83 / 2.01

1.71 / 1.88

1.77 / 1.95

2.79 / 3.09

2.56 / 2.81

2.41 / 2.65

2.61 / 2.90

2.41 / 2.65

2.38 / 2.68

2.22 / 2.48

2.02 / 2.23

1.89 / 2.09

1.78 / 1.96

2.07 / 2.31

Unit D

2.20 / 2.62

2.18 / 2.57

2.11 / 2.40

1.91 / 2.14

1.78 / 1.99

1.67 / 1.85

2.46 / 2.84

2.36 / 2.66

2.13 / 2.38

2.00 / 2.22

1.87 / 2.07

3.09 / 3.45

2.80 / 3.11

2.63 / 2.91

2.48 / 2.73

3.64 / 4.04

3.47 / 3.81

2.42 / 2.79

2.31 / 2.60

2.08 / 2.33

1.96 / 2.18

1.83 / 2.03

3.02 / 3.37

2.75 / 3.05

2.58 / 2.86

2.44 / 2.68

3.61 / 3.96

3.41 / 3.74

2.82 / 3.15

2.58 / 2.86

2.45 / 2.70

3.41 / 3.74

2.40 / 2.73

2.25 / 2.54

2.04 / 2.28

1.93 / 2.13

1.82 / 1.99

2.96 / 3.30

2.70 / 2.99

2.56 / 2.81

2.40 / 2.63

3.55 / 3.90

2.79 / 3.09

2.56 / 2.81

2.41 / 2.65

2.61 / 2.90

2.41 / 2.65

2.38 / 2.68

2.22 / 2.48

2.02 / 2.23

1.89 / 2.09

1.78 / 1.96

2.90 / 3.23

Unit E

2.20 / 2.62

2.48 / 2.92

3.36 / 3.81

4.35 / 4.86

4.86 / 5.43

5.40 / 5.98

2.46 / 2.84

3.31 / 3.72

4.26 / 4.75

4.81 / 5.32

5.30 / 5.87

3.09 / 3.45

4.01 / 4.44

4.51 / 4.99

5.04 / 5.53

3.64 / 4.04

4.16 / 4.57

2.42 / 2.79

3.23 / 3.64

4.17 / 4.65

4.71 / 5.22

5.21 / 5.77

3.02 / 3.37

3.93 / 4.35

4.43 / 4.90

4.95 / 5.44

3.61 / 3.96

4.09 / 4.49

2.82 / 3.15

3.69 / 4.09

4.21 / 4.62

3.41 / 3.74

2.40 / 2.73

3.17 / 3.55

4.08 / 4.56

4.62 / 5.12

5.16 / 5.66

2.96 / 3.30

3.85 / 4.27

4.38 / 4.81

4.87 / 5.34

3.55 / 3.90

2.79 / 3.09

3.65 / 4.01

4.14 / 4.54

2.61 / 2.90

3.45 / 3.79

2.38 / 2.68

3.12 / 3.47

4.03 / 4.47

4.54 / 5.03

5.07 / 5.56

2.90 / 3.23

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 45

4 ROOMS22 + 22 + 22 + 22

22 + 22 + 22 + 25

22 + 22 + 22 + 35

22 + 22 + 22 + 50

22 + 22 + 22 + 60

22 + 22 + 22 + 71

22 + 22 + 25 + 25

22 + 22 + 25 + 35

22 + 22 + 25 + 50

22 + 22 + 25 + 60

22 + 22 + 25 + 71

22 + 22 + 35 + 35

22 + 22 + 35 + 50

22 + 22 + 35 + 60

22 + 22 + 35 + 71

22 + 22 + 50 + 50

22 + 22 + 50 + 60

22 + 22 + 50 + 71

22 + 22 + 60 + 60

22 + 22 + 60 + 71

22 + 25 + 25 + 25

22 + 25 + 25 + 35

22 + 25 + 25 + 50

22 + 25 + 25 + 60

22 + 25 + 25 + 71

22 + 25 + 35 + 35

22 + 25 + 35 + 50

22 + 25 + 35 + 60

22 + 25 + 35 + 71

22 + 25 + 50 + 50

22 + 25 + 50 + 60

22 + 25 + 50 + 71

22 + 25 + 60 + 60

22 + 25 + 60 + 71

22 + 35 + 35 + 35

22 + 35 + 35 + 50

Unit A

2.20 / 2.85

2.20 / 2.80

2.18 / 2.61

1.95 / 2.37

1.83 / 2.23

1.70 / 2.10

2.20 / 2.74

2.14 / 2.56

1.90 / 2.33

1.79 / 2.20

1.68 / 2.07

1.97 / 2.39

1.79 / 2.20

1.69 / 2.09

1.57 / 1.94

1.63 / 2.02

1.54 / 1.89

1.44 / 1.76

1.45 / 1.77

1.36 / 1.58

2.20 / 270

2.08 / 2.51

1.88 / 2.29

1.77 / 2.17

1.65 / 2.03

1.94 / 2.35

1.77 / 2.17

1.66 / 2.05

1.54 / 1.90

1.60 / 1.98

1.51 / 1.85

1.41 / 1.73

1.42 / 1.74

1.33 / 1.56

1.83 / 2.22

1.66 / 2.05

Unit B

2.20 / 2.85

2.20 / 2.80

2.18 / 2.61

1.95 / 2.37

1.83 / 2.23

1.70 / 2.10

2.20 / 2.74

2.14 / 2.56

1.90 / 2.33

1.79 / 2.20

1.68 / 2.07

1.97 / 2.39

1.79 / 2.20

1.69 / 2.09

1.57 / 1.94

1.63 / 2.02

1.54 / 1.89

1.44 / 1.76

1.45 / 1.77

1.36 / 1.58

2.50 / 3.07

2.36 / 2.85

2.13 / 2.60

2.01 / 2.46

1.87 / 2.31

2.20 / 2.67

2.01 / 2.46

1.88 / 2.32

1.75 / 2.16

1.82 / 2.24

1.72 / 2.10

1.61 / 1.96

1.62 / 1.98

1.52 / 1.77

2.89 / 3.53

2.64 / 3.25

Unit C

2.20 / 2.85

2.20 / 2.80

2.18 / 2.61

1.95 / 2.37

1.83 / 2.23

1.70 / 2.10

2.50 / 3.11

2.43 / 2.91

2.16 / 2.65

2.03 / 2.50

1.91 / 2.36

3.13 / 3.81

2.85 / 3.50

2.69 / 3.32

2.50 / 3.08

3.72 / 4.58

3.51 / 4.29

3.27 / 4.00

3.95 / 4.83

3.70 / 4.32

2.50 / 3.07

2.36 / 2.85

2.13 / 2.60

2.01 / 2.46

1.87 / 2.31

3.08 / 3.74

2.81 / 3.45

2.64 / 3.25

2.45 / 3.02

3.64 / 4.49

3.44 / 4.20

3.21 / 3.93

3.88 / 4.74

3.64 / 4.25

2.89 / 3.53

2.64 / 3.25

Unit D

2.20 / 2.85

2.50 / 3.19

3.47 / 4.17

4.44 / 5.39

5.00 / 6.10

5.49 / 6.79

2.50 / 3.11

3.40 / 4.07

4.33 / 5.29

4.88 / 6.00

5.43 / 6.69

3.13 / 3.81

4.07 / 5.00

4.62 / 5.70

5.06 / 6.25

3.72 / 4.58

4.21 / 5.14

4.65 / 5.68

3.95 / 4.83

4.38 / 5.11

2.50 / 3.07

3.30 / 3.99

4.26 / 5.20

4.82 / 5.91

5.31 / 6.55

3.08 / 3.74

4.02 / 4.92

4.52 / 5.58

4.97 / 6.13

3.64 / 4.49

4.13 / 5.04

4.56 / 5.58

3.88 / 4.74

4.31 / 5.03

2.89 / 3.53

3.77 / 4.65

Indoor unitcombination

Cooling / Heating Capacity (kW)

22 + 35 + 35 + 60

22 + 35 + 35 + 71

22 + 35 + 50 + 50

22 + 35 + 50 + 60

22 + 35 + 50 + 71

22 + 35 + 60 + 60

22 + 50 + 50 + 50

25 + 25 + 25 + 25

25 + 25 + 25 + 35

25 + 25 + 25 + 50

25 + 25 + 25 + 60

25 + 25 + 25 + 71

25 + 25 + 35 + 35

25 + 25 + 35 + 50

25 + 25 + 35 + 60

25 + 25 + 35 + 71

25 + 25 + 50 + 50

25 + 25 + 50 + 60

25 + 25 + 50 + 71

25 + 25 + 60 + 60

25 + 35 + 35 + 35

25 + 35 + 35 + 50

25 + 35 + 35 + 60

25 + 35 + 35 + 71

25 + 35 + 50 + 50

25 + 35 + 50 + 60

25 + 35 + 60 + 60

25 + 50 + 50 + 50

35 + 35 + 35 + 35

35 + 35 + 35 + 50

35 + 35 + 35 + 60

35 + 35 + 35 + 71

35 + 35 + 50 + 50

35 + 35 + 50 + 60

Unit A

1.55 / 1.91

1.46 / 1.78

1.51 / 1.85

1.42 / 1.74

1.33 / 1.56

1.34 / 1.57

1.38 / 1.61

2.50 / 3.00

2.32 / 2.80

2.08 / 2.56

1.96 / 2.43

1.83 / 2.26

2.17 / 2.63

1.96 / 2.43

1.84 / 2.28

1.73 / 2.12

1.78 / 2.20

1.69 / 2.06

1.58 / 1.84

1.59 / 1.85

2.02 / 2.48

1.84 / 2.28

1.74 / 2.13

1.63 / 1.99

1.69 / 2.06

1.59 / 1.85

150 / 1.75

1.54 / 1.80

2.68 / 3.30

2.44 / 2.98

2.29 / 2.80

2.15 / 2.51

2.22 / 2.59

2.10 / 2.45

Unit B

2.46 / 3.04

2.32 / 2.83

2.41 / 2.94

2.26 / 2.77

2.12 / 2.48

2.14 / 2.49

3.14 / 3.66

2.50 / 3.00

2.32 / 2.80

2.08 / 2.56

1.96 / 2.43

1.83 / 2.26

2.17 / 2.63

1.96 / 2.43

1.84 / 2.28

1.73 / 2.12

1.78 / 2.20

1.69 / 2.06

1.58 / 1.84

1.59 / 1.85

2.83 / 3.47

2.58 / 3.19

2.44 / 2.98

2.28 / 2.78

2.36 / 2.89

2.22 / 2.59

2.10 / 2.45

3.09 / 3.60

2.68 / 3.30

2.44 / 2.98

2.29 / 2.80

2.15 / 2.51

2.22 / 2.59

2.10 / 2.45

Unit C

2.46 / 3.04

2.32 / 2.83

3.44 / 4.20

3.23 / 3.95

3.03 / 3.54

3.66 / 4.27

3.14 / 3.66

2.50 / 3.00

2.32 / 2.80

2.08 / 2.56

1.96 / 2.43

1.83 / 2.26

3.03 / 3.68

2.75 / 3.40

2.58 / 3.19

2.42 / 2.96

3.57 / 4.40

3.38 / 4.13

3.16 / 3.68

3.81 / 4.45

2.83 / 3.47

2.58 / 3.19

2.44 / 2.98

2.28 / 2.78

3.38 / 4.13

3.18 / 3.71

3.60 / 4.20

3.09 / 3.60

2.68 / 3.30

2.44 / 2.98

2.29 / 2.80

2.15 / 2.51

3.18 / 3.71

3.00 / 3.50

Unit D

4.22 / 5.21

4.70 / 5.75

3.44 / 4.20

3.88 / 4.74

4.31 / 5.03

3.66 / 4.27

3.14 / 3.66

2.50 / 3.00

3.25 / 3.91

4.16 / 5.12

4.71 / 5.82

5.20 / 6.42

3.03 / 3.68

3.93 / 4.85

4.43 / 5.46

4.92 / 6.01

3.57 / 4.40

4.05 / 4.95

4.48 / 5.23

3.81 / 4.45

2.83 / 3.47

3.69 / 4.55

4.18 / 5.11

4.62 / 5.65

3.38 / 4.13

3.81 / 4.45

3.60 / 4.20

3.09 / 3.60

2.68 / 3.30

3.48 / 4.26

3.93 / 4.80

4.36 / 5.08

3.18 / 3.71

3.60 / 4.20

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 44

Page 27: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

1 ROOM22

25

35

50

60

71

100

2 ROOMS22 + 22

22 + 25

22 + 35

22 + 50

22 + 60

22 + 71

22 + 100

25 + 25

25 + 35

25 + 50

25 + 60

25 + 71

25 + 100

35 + 35

35 + 50

35 + 60

35 + 71

35 + 100

50 + 50

50 + 60

50 + 71

60 + 60

60 + 71

60 + 100

71 + 71

71 + 100

3 ROOMS22 + 22 + 22

22 + 22 + 25

22 + 22 + 35

22 + 22 + 50

22 + 22 + 60

22 + 22 + 71

22 + 22 + 100

22 + 25 + 25

22 + 25 + 35

Unit A

2.20 / 3.30

2.50 / 3.60

3.50 / 4.00

5.00 / 7.20

6.00 / 7.90

7.10 / 8.60

10.00 / 11.20

2.20 / 2.50

2.20 / 2.53

2.20 / 2.51

2.20 / 2.51

2.20 / 2.52

2.20 / 2.51

2.20 / 2.51

2.50 / 2.85

2.50 / 2.88

2.50 / 2.87

2.50 / 2.85

2.50 / 2.86

2.50 / 2.86

3.50 / 4.00

3.50 / 3.99

3.50 / 4.02

3.50 / 4.00

3.50 / 3.99

5.00 / 5.70

5.00 / 5.73

5.00 / 5.70

6.00 / 6.85

6.00 / 6.87

5.25 / 6.00

7.00 / 8.00

5.81 / 6.64

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.14 / 2.44

2.20 / 2.51

2.20 / 2.52

Unit B

2.20 / 2.50

2.50 / 2.87

3.50 / 3.99

5.00 / 5.69

6.00 / 6.88

7.10 / 8.09

10.00 / 11.39

2.50 / 2.85

3.50 / 4.03

5.00 / 5.73

6.00 / 6.85

7.10 / 8.14

10.00 / 11.44

3.50 / 4.00

5.00 / 5.71

6.00 / 6.88

7.10 / 8.10

10.00 / 11.41

5.00 / 5.70

6.00 / 6.87

7.10 / 8.10

6.00 / 6.85

7.10 / 8.13

8.75 / 10.00

7.00 / 8.00

8.19 / 9.36

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.14 / 2.44

2.50 / 2.85

2.50 / 2.87

Unit C

­­­­­

2.20 / 2.50

2.50 / 2.86

3.50 / 3.99

5.00 / 5.69

6.00 / 6.87

7.10 / 8.09

9.72 / 11.11

2.50 / 2.85

3.50 / 4.01

Unit D

Indoor unitcombination

Cooling / Heating Capacity (kW)

MXZ-8B140VA1Outdoor Unit Up to 8 Indoor Units

22 + 25 + 50

22 + 25 + 60

22 + 25 + 71

22 + 25 + 100

22 + 35 + 35

22 + 35 + 50

22 + 35 + 60

22 + 35 + 71

22 + 35 + 100

22 + 50 + 50

22 + 50 + 60

22 + 50 + 71

22 + 50 + 100

22 + 60 + 60

22 + 60 + 71

22 + 60 + 100

22 + 71 + 71

25 + 25 + 25

25 + 25 + 35

25 + 25 + 50

25 + 25 + 60

25 + 25 + 71

25 + 25 + 100

25 + 35 + 35

25 + 35 + 50

25 + 35 + 60

25 + 35 + 71

25 + 35 + 100

25 + 50 + 50

25 + 50 + 60

25 + 50 + 71

25 + 50 + 100

25 + 60 + 60

25 + 60 + 71

25 + 60 + 100

25 + 71 + 71

35 + 35 + 35

35 + 35 + 50

35 + 35 + 60

35 + 35 + 71

35 + 35 + 100

35 + 50 + 50

35 + 50 + 60

35 + 50 + 71

35 + 50 + 100

35 + 60 + 60

35 + 60 + 71

35 + 71 + 71

50 + 50 + 50

50 + 50 + 60

50 + 50 + 71

50 + 60 + 60

50 + 60 + 71

60 + 60 + 60

Unit A

2.20 / 2.52

2.20 / 2.51

2.20 / 2.52

2.10 / 2.39

2.20 / 2.51

2.20 / 2.51

2.20 / 2.52

2.20 / 2.51

1.96 / 2.24

2.20 / 2.51

2.20 / 2.52

2.15 / 2.46

1.79 / 2.05

2.17 / 2.48

2.01 / 2.30

1.69 / 1.93

1.88 / 2.15

2.50 / 2.87

2.50 / 2.85

2.50 / 2.85

2.50 / 2.86

2.50 / 2.85

2.33 / 2.67

2.50 / 2.87

2.50 / 2.86

2.50 / 2.85

2.50 / 2.86

2.19 / 2.50

2.50 / 2.86

2.50 / 2.85

2.40 / 2.74

2.00 / 2.29

2.41 / 2.76

2.24 / 2.56

1.89 / 2.16

2.10 / 2.40

3.50 / 4.00

3.50 / 4.00

3.50 / 4.01

3.48 / 3.97

2.88 / 3.29

3.50 / 3.99

3.38 / 3.86

3.14 / 3.59

2.65 / 3.03

3.16 / 3.61

2.95 / 3.37

2.77 / 3.16

4.67 / 5.33

4.38 / 5.00

4.09 / 4.68

4.12 / 4.71

3.87 / 4.42

4.67 / 5.33

Unit B

2.50 / 2.86

2.50 / 2.85

2.50 / 2.86

2.38 / 2.72

3.50 / 3.99

3.50 / 3.99

3.50 / 4.01

3.50 / 3.99

3.12 / 3.57

5.00 / 5.70

5.00 / 5.72

4.90 / 5.59

4.07 / 4.65

5.92 / 6.76

5.49 / 6.27

4.62 / 5.27

6.06 / 6.93

2.50 / 2.87

2.50 / 2.85

2.50 / 2.85

2.50 / 2.86

2.50 / 2.85

2.33 / 2.67

3.50 / 4.02

3.50 / 4.01

3.50 / 4.00

3.50 / 4.01

3.06 / 3.50

5.00 / 5.72

5.00 / 5.70

4.79 / 5.48

4.00 / 4.57

5.79 / 6.62

5.38 / 6.15

4.54 / 5.19

5.95 / 6.80

3.50 / 4.00

3.50 / 4.00

3.50 / 4.01

3.48 / 3.97

2.88 / 3.29

5.00 / 5.70

4.83 / 5.52

4.49 / 5.13

3.78 / 4.32

5.42 / 6.19

5.06 / 5.78

5.62 / 6.42

4.67 / 5.33

4.38 / 5.00

4.09 / 4.68

4.94 / 5.65

4.64 / 5.30

4.67 / 5.33

Unit C

5.00 / 5.72

6.00 / 6.84

7.10 / 8.12

9.52 / 10.88

3.50 / 3.99

5.00 / 5.70

6.00 / 6.87

7.10 / 8.10

8.92 / 10.19

5.00 / 5.70

6.00 / 6.86

6.95 / 7.94

8.14 / 9.30

5.92 / 6.76

6.50 / 7.42

7.69 / 8.79

6.06 / 6.93

2.50 / 2.87

3.50 / 3.99

5.00 / 5.70

6.00 / 6.87

7.10 / 8.10

9.33 / 10.67

3.50 / 4.02

5.00 / 5.73

6.00 / 6.85

7.10 / 8.13

8.75 / 10.00

5.00 / 5.72

6.00 / 6.84

6.81 / 7.78

8.00 / 9.14

5.79 / 6.62

6.37 / 7.28

7.57 / 8.65

5.95 / 6.80

3.50 / 4.00

5.00 / 5.71

6.00 / 6.88

7.05 / 8.06

8.24 / 9.41

5.00 / 5.70

5.79 / 6.62

6.37 / 7.28

7.57 / 8.65

5.42 / 6.19

5.99 / 6.84

5.62 / 6.42

4.67 / 5.33

5.25 / 6.00

5.81 / 6.64

4.94 / 5.65

5.49 / 6.28

4.67 / 5.33

Unit D

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 47

25 + 25 + 25 + 35 + 50

25 + 25 + 25 + 35 + 60

25 + 25 + 25 + 50 + 50

25 + 25 + 35 + 35 + 35

25 + 25 + 35 + 35 + 50

25 + 25 + 35 + 35 + 60

25 + 35 + 35 + 35 + 35

25 + 35 + 35 + 35 + 50

35 + 35 + 35 + 35 + 35

6 ROOMS22 + 22 + 22 + 22 + 22 + 22

22 + 22 + 22 + 22 + 22 + 25

22 + 22 + 22 + 22 + 22 + 35

22 + 22 + 22 + 22 + 22 + 50

22 + 22 + 22 + 22 + 22 + 60

22 + 22 + 22 + 22 + 25 + 25

22 + 22 + 22 + 22 + 25 + 35

22 + 22 + 22 + 22 + 25 + 50

22 + 22 + 22 + 22 + 25 + 60

22 + 22 + 22 + 22 + 35 + 35

22 + 22 + 22 + 22 + 35 + 50

22 + 22 + 22 + 25 + 25 + 25

22 + 22 + 22 + 25 + 25 + 35

22 + 22 + 22 + 25 + 25 + 50

22 + 22 + 22 + 25 + 25 + 60

22 + 22 + 22 + 25 + 35 + 35

22 + 22 + 22 + 25 + 35 + 50

22 + 22 + 22 + 35 + 35 + 35

22 + 22 + 25 + 25 + 25 + 25

22 + 22 + 25 + 25 + 25 + 35

22 + 22 + 25 + 25 + 25 + 50

22 + 22 + 25 + 25 + 25 + 60

22 + 22 + 25 + 25 + 35 + 35

22 + 22 + 25 + 25 + 35 + 50

22 + 22 + 25 + 35 + 35 + 35

22 + 25 + 25 + 25 + 25 + 25

22 + 25 + 25 + 25 + 25 + 35

22 + 25 + 25 + 25 + 25 + 50

22 + 25 + 25 + 25 + 35 + 35

22 + 25 + 25 + 35 + 35 + 35

25 + 25 + 25 + 25 + 25 + 25

25 + 25 + 25 + 25 + 25 + 35

25 + 25 + 25 + 25 + 25 + 50

25 + 25 + 25 + 25 + 35 + 35

25 + 25 + 25 + 35 + 35 + 35

Unit A

1.89 / 2.09

1.79 / 1.97

1.74 / 1.91

1.95 / 2.16

1.79 / 1.97

1.69 / 1.86

1.83 / 2.03

1.69 / 1.86

2.44 / 2.68

2.00 / 2.33

1.96 / 2.28

1.82 / 2.12

1.65 / 1.93

1.55 / 1.81

1.91 / 2.23

1.78 / 2.08

1.62 / 1.89

1.53 / 1.78

1.67 / 1.95

1.53 / 1.78

1.87 / 2.18

1.75 / 2.04

1.59 / 1.86

1.50 / 1.75

1.64 / 1.91

1.50 / 1.75

1.54 / 1.80

1.83 / 2.14

1.71 / 2.00

1.56 / 1.82

1.47 / 1.72

1.61 / 1.88

1.47 / 1.72

1.52 / 1.77

1.80 / 2.10

1.68 / 1.96

1.53 / 1.79

1.58 / 1.84

1.49 / 1.74

2.00 / 2.33

1.88 / 2.19

1.71 / 2.00

1.76 / 2.06

1.67 / 1.94

Unit B

1.89 / 2.09

1.79 / 1.97

1.74 / 1.91

1.95 / 2.16

1.79 / 1.97

1.69 / 1.86

2.57 / 2.84

2.37 / 2.61

2.44 / 2.68

2.00 / 2.33

1.96 / 2.28

1.82 / 2.12

1.65 / 1.93

1.55 / 1.81

1.91 / 2.23

1.78 / 2.08

1.62 / 1.89

1.53 / 1.78

1.67 / 1.95

1.53 / 1.78

1.87 / 2.18

1.75 / 2.04

1.59 / 1.86

1.50 / 1.75

1.64 / 1.91

1.50 / 1.75

1.54 / 1.80

1.83 / 2.14

1.71 / 2.00

1.56 / 1.82

1.47 / 1.72

1.61 / 1.88

1.47 / 1.72

1.52 / 1.77

2.04 / 2.38

1.91 / 2.23

1.74 / 2.03

1.80 / 2.10

1.69 / 1.98

2.00 / 2.33

1.88 / 2.19

1.71 / 2.00

1.76 / 2.06

1.67 / 1.94

Unit C

1.89 / 2.09

1.79 / 1.97

1.74 / 1.91

2.73 / 3.03

2.51 / 2.76

2.37 / 2.61

2.57 / 2.84

2.37 / 2.61

2.44 / 2.68

2.00 / 2.33

1.96 / 2.28

1.82 / 2.12

1.65 / 1.93

1.55 / 1.81

1.91 / 2.23

1.78 / 2.08

1.62 / 1.89

1.53 / 1.78

1.67 / 1.95

1.53 / 1.78

1.87 / 2.18

1.75 / 2.04

1.59 / 1.86

1.50 / 1.75

1.64 / 1.91

1.50 / 1.75

1.54 / 1.80

2.08 / 2.43

1.95 / 2.27

1.78 / 2.07

1.68 / 1.96

1.83 / 2.13

1.68 / 1.96

1.72 / 2.01

2.04 / 2.38

1.91 / 2.23

1.74 / 2.03

1.80 / 2.10

1.69 / 1.98

2.00 / 2.33

1.88 / 2.19

1.71 / 2.00

1.76 / 2.06

1.67 / 1.94

Unit D

2.65 / 2.93

2.51 / 2.76

3.49 / 3.83

2.73 / 3.03

2.51 / 2.76

2.37 / 2.61

2.57 / 2.84

2.37 / 2.61

2.44 / 2.68

2.00 / 2.33

1.96 / 2.28

1.82 / 2.12

1.65 / 1.93

1.55 / 1.81

1.91 / 2.23

1.78 / 2.08

1.62 / 1.89

1.53 / 1.78

1.67 / 1.95

1.53 / 1.78

2.13 / 2.48

1.99 / 2.32

1.81 / 2.11

1.70 / 1.99

1.86 / 2.17

1.70 / 1.99

2.46 / 2.87

2.08 / 2.43

1.95 / 2.27

1.78 / 2.07

1.68 / 1.96

1.83 / 2.13

1.68 / 1.96

2.41 / 2.82

2.04 / 2.38

1.91 / 2.23

1.74 / 2.03

1.80 / 2.10

2.37 / 2.77

2.00 / 2.33

1.88 / 2.19

1.71 / 2.00

1.76 / 2.06

2.33 / 2.72

Unit E

3.78 / 4.19

4.31 / 4.73

3.49 / 3.83

2.73 / 3.03

3.59 / 3.94

4.07 / 4.47

2.57 / 2.84

3.39 / 3.72

2.44 / 2.68

2.00 / 2.33

1.96 / 2.28

1.82 / 2.12

1.65 / 1.93

1.55 / 1.81

2.17 / 2.54

2.03 / 2.36

1.84 / 2.15

1.73 / 2.02

2.66 / 3.10

2.43 / 2.83

2.13 / 2.48

1.99 / 2.32

1.81 / 2.11

1.70 / 1.99

2.61 / 3.04

2.39 / 2.78

2.46 / 2.87

2.08 / 2.43

1.95 / 2.27

1.78 / 2.07

1.68 / 1.96

2.56 / 2.99

2.35 / 2.74

2.41 / 2.82

2.04 / 2.38

1.91 / 2.23

1.74 / 2.03

2.51 / 2.93

2.37 / 2.77

2.00 / 2.33

1.88 / 2.19

1.71 / 2.00

2.47 / 2.88

2.33 / 2.72

Unit F

2.00 / 2.33

2.22 / 2.59

2.90 / 3.38

3.75 / 4.38

4.24 / 4.94

2.17 / 2.54

2.84 / 3.31

3.68 / 4.29

4.16 / 4.86

2.66 / 3.10

3.47 / 4.05

2.13 / 2.48

2.78 / 3.25

3.61 / 4.22

4.09 / 4.77

2.61 / 3.04

3.41 / 3.98

2.46 / 2.87

2.08 / 2.43

2.73 / 3.18

3.55 / 4.14

4.02 / 4.69

2.56 / 2.99

3.35 / 3.91

2.41 / 2.82

2.04 / 2.38

2.68 / 3.12

3.49 / 4.07

2.51 / 2.93

2.37 / 2.77

2.00 / 2.33

2.63 / 3.06

3.43 / 4.00

2.47 / 2.88

2.33 / 2.72

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 46

Page 28: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

5 ROOMS22 + 22 + 22 + 22 + 22

22 + 22 + 22 + 22 + 25

22 + 22 + 22 + 22 + 35

22 + 22 + 22 + 22 + 50

22 + 22 + 22 + 22 + 60

22 + 22 + 22 + 22 + 71

22 + 22 + 22 + 25 + 25

22 + 22 + 22 + 25 + 35

22 + 22 + 22 + 25 + 50

22 + 22 + 22 + 25 + 60

22 + 22 + 22 + 25 + 71

22 + 22 + 22 + 35 + 35

22 + 22 + 22 + 35 + 50

22 + 22 + 22 + 35 + 60

22 + 22 + 22 + 35 + 71

22 + 22 + 22 + 50 + 50

22 + 22 + 22 + 50 + 60

22 + 22 + 25 + 25 + 25

22 + 22 + 25 + 25 + 35

22 + 22 + 25 + 25 + 50

22 + 22 + 25 + 25 + 60

22 + 22 + 25 + 25 + 71

22 + 22 + 25 + 35 + 35

22 + 22 + 25 + 35 + 50

22 + 22 + 25 + 35 + 60

22 + 22 + 25 + 35 + 71

22 + 22 + 25 + 50 + 50

22 + 22 + 25 + 50 + 60

22 + 22 + 35 + 35 + 35

22 + 22 + 35 + 35 + 50

22 + 22 + 35 + 35 + 60

22 + 22 + 35 + 35 + 71

22 + 22 + 35 + 50 + 50

22 + 25 + 25 + 25 + 25

22 + 25 + 25 + 25 + 35

22 + 25 + 25 + 25 + 50

22 + 25 + 25 + 25 + 60

22 + 25 + 25 + 25 + 71

22 + 25 + 25 + 35 + 35

22 + 25 + 25 + 35 + 50

22 + 25 + 25 + 35 + 60

22 + 25 + 25 + 35 + 71

22 + 25 + 25 + 50 + 50

22 + 25 + 25 + 50 + 60

22 + 25 + 35 + 35 + 35

22 + 25 + 35 + 35 + 50

22 + 25 + 35 + 35 + 60

22 + 25 + 35 + 50 + 50

22 + 35 + 35 + 35 + 35

22 + 35 + 35 + 35 + 50

Unit A

2.20 / 2.52

2.20 / 2.51

2.20 / 2.52

2.20 / 2.52

2.08 / 2.38

1.94 / 2.21

2.20 / 2.52

2.20 / 2.51

2.18 / 2.50

2.04 / 2.33

1.90 / 2.17

2.20 / 2.51

2.04 / 2.33

1.91 / 2.19

1.79 / 2.05

1.86 / 2.12

1.75 / 2.00

2.20 / 2.51

2.20 / 2.51

2.14 / 2.44

2.00 / 2.29

1.87 / 2.13

2.20 / 2.52

2.00 / 2.29

1.88 / 2.15

1.76 / 2.01

1.82 / 2.08

1.72 / 1.97

2.07 / 2.36

1.88 / 2.15

1.77 / 2.02

1.66 / 1.90

1.72 / 1.97

2.20 / 2.51

2.20 / 2.52

2.10 / 2.39

1.96 / 2.24

1.83 / 2.10

2.17 / 2.48

1.96 / 2.24

1.84 / 2.11

1.73 / 1.98

1.79 / 2.05

1.69 / 1.93

2.03 / 2.32

1.84 / 2.11

1.74 / 1.99

1.69 / 1.93

1.90 / 2.17

1.74 / 1.99

Unit B

2.20 / 2.52

2.20 / 2.51

2.20 / 2.52

2.20 / 2.52

2.08 / 2.38

1.94 / 2.21

2.20 / 2.52

2.20 / 2.51

2.18 / 2.50

2.04 / 2.33

1.90 / 2.17

2.20 / 2.51

2.04 / 2.33

1.91 / 2.19

1.79 / 2.05

1.86 / 2.12

1.75 / 2.00

2.20 / 2.51

2.20 / 2.51

2.14 / 2.44

2.00 / 2.29

1.87 / 2.13

2.20 / 2.52

2.00 / 2.29

1.88 / 2.15

1.76 / 2.01

1.82 / 2.08

1.72 / 1.97

2.07 / 2.36

1.88 / 2.15

1.77 / 2.02

1.66 / 1.90

1.72 / 1.97

2.50 / 2.85

2.50 / 2.86

2.38 / 2.72

2.23 / 2.55

2.08 / 2.38

2.46 / 2.82

2.23 / 2.55

2.10 / 2.40

1.97 / 2.25

2.03 / 2.33

1.92 / 2.20

2.30 / 2.63

2.10 / 2.40

1.98 / 2.26

1.92 / 2.20

3.02 / 3.46

2.77 / 3.16

Unit C

2.20 / 2.52

2.20 / 2.51

2.20 / 2.52

2.20 / 2.52

2.08 / 2.38

1.94 / 2.21

2.20 / 2.52

2.20 / 2.51

2.18 / 2.50

2.04 / 2.33

1.90 / 2.17

2.20 / 2.51

2.04 / 2.33

1.91 / 2.19

1.79 / 2.05

1.86 / 2.12

1.75 / 2.00

2.50 / 2.86

2.50 / 2.85

2.43 / 2.78

2.27 / 2.60

2.12 / 2.42

2.50 / 2.86

2.27 / 2.60

2.13 / 2.44

2.00 / 2.29

2.07 / 2.37

1.96 / 2.23

3.29 / 3.76

2.99 / 3.41

2.82 / 3.22

2.65 / 3.03

2.74 / 3.13

2.50 / 2.85

2.50 / 2.86

2.38 / 2.72

2.23 / 2.55

2.08 / 2.38

2.46 / 2.82

2.23 / 2.55

2.10 / 2.40

1.97 / 2.25

2.03 / 2.33

1.92 / 2.20

3.22 / 3.68

2.93 / 3.35

2.77 / 3.16

2.69 / 3.08

3.02 / 3.46

2.77 / 3.16

Unit D

2.20 / 2.52

2.20 / 2.51

2.20 / 2.52

2.20 / 2.52

2.08 / 2.38

1.94 / 2.21

2.50 / 2.87

2.50 / 2.86

2.48 / 2.84

2.32 / 2.65

2.16 / 2.47

3.50 / 3.99

3.25 / 3.71

3.04 / 3.48

2.85 / 3.26

4.22 / 4.82

3.98 / 4.55

2.50 / 2.86

2.50 / 2.85

2.43 / 2.78

2.27 / 2.60

2.12 / 2.42

3.50 / 4.00

3.18 / 3.64

2.99 / 3.41

2.80 / 3.20

4.14 / 4.73

3.91 / 4.47

3.29 / 3.76

2.99 / 3.41

2.82 / 3.22

2.65 / 3.03

3.91 / 4.47

2.50 / 2.85

2.50 / 2.86

2.38 / 2.72

2.23 / 2.55

2.08 / 2.38

3.45 / 3.94

3.12 / 3.57

2.93 / 3.35

2.75 / 3.15

4.07 / 4.65

3.85 / 4.40

3.22 / 3.68

2.93 / 3.35

2.77 / 3.16

3.85 / 4.40

3.02 / 3.46

2.77 / 3.16

Unit E

2.20 / 2.52

2.50 / 2.85

3.50 / 4.01

5.00 / 5.72

5.68 / 6.49

6.25 / 7.14

2.50 / 2.87

3.50 / 4.00

4.96 / 5.67

5.56 / 6.36

6.14 / 7.01

3.50 / 3.99

4.64 / 5.30

5.22 / 5.96

5.78 / 6.60

4.22 / 4.82

4.77 / 5.45

2.50 / 2.86

3.50 / 3.99

4.86 / 5.56

5.45 / 6.23

6.02 / 6.88

3.50 / 4.00

4.55 / 5.19

5.12 / 5.85

5.68 / 6.49

4.14 / 4.73

4.69 / 5.36

3.29 / 3.76

4.27 / 4.88

4.83 / 5.52

5.37 / 6.14

3.91 / 4.47

2.50 / 2.85

3.50 / 4.00

4.76 / 5.44

5.35 / 6.11

5.92 / 6.76

3.45 / 3.94

4.46 / 5.10

5.03 / 5.75

5.58 / 6.38

4.07 / 4.65

4.62 / 5.27

3.22 / 3.68

4.19 / 4.79

4.75 / 5.42

3.85 / 4.40

3.02 / 3.46

3.95 / 4.52

Unit F Unit G Unit H

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 49

4 ROOMS

22 + 22 + 22 + 22

22 + 22 + 22 + 25

22 + 22 + 22 + 35

22 + 22 + 22 + 50

22 + 22 + 22 + 60

22 + 22 + 22 + 71

22 + 22 + 22 + 100

22 + 22 + 25 + 25

22 + 22 + 25 + 35

22 + 22 + 25 + 50

22 + 22 + 25 + 60

22 + 22 + 25 + 71

22 + 22 + 25 + 100

22 + 22 + 35 + 35

22 + 22 + 35 + 50

22 + 22 + 35 + 60

22 + 22 + 35 + 71

22 + 22 + 35 + 100

22 + 22 + 50 + 50

22 + 22 + 50 + 60

22 + 22 + 50 + 71

22 + 22 + 60 + 60

22 + 22 + 60 + 71

22 + 25 + 25 + 25

22 + 25 + 25 + 35

22 + 25 + 25 + 50

22 + 25 + 25 + 60

22 + 25 + 25 + 71

22 + 25 + 25 + 100

22 + 25 + 35 + 35

22 + 25 + 35 + 50

22 + 25 + 35 + 60

22 + 25 + 35 + 71

22 + 25 + 35 + 100

22 + 25 + 50 + 50

22 + 25 + 50 + 60

22 + 25 + 50 + 71

22 + 25 + 60 + 60

22 + 25 + 60 + 71

22 + 35 + 35 + 35

22 + 35 + 35 + 50

Unit A

2.20 / 2.53

2.20 / 2.51

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.20 / 2.52

1.86 / 2.12

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.20 / 2.51

2.20 / 2.51

1.82 / 2.08

2.20 / 2.51

2.20 / 2.51

2.20 / 2.52

2.05 / 2.35

1.72 / 1.97

2.14 / 2.44

2.00 / 2.29

1.87 / 2.13

1.88 / 2.15

1.76 / 2.01

2.20 / 2.52

2.20 / 2.51

2.20 / 2.51

2.20 / 2.52

2.15 / 2.46

1.79 / 2.05

2.20 / 2.52

2.20 / 2.52

2.17 / 2.48

2.01 / 2.30

1.69 / 1.93

2.10 / 2.39

1.96 / 2.24

1.83 / 2.10

1.84 / 2.10

1.73 / 1.98

2.20 / 2.51

2.17 / 2.48

Unit B

2.20 / 2.53

2.20 / 2.51

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.20 / 2.52

1.86 / 2.12

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.20 / 2.51

2.20 / 2.51

1.82 / 2.08

2.20 / 2.51

2.20 / 2.51

2.20 / 2.52

2.05 / 2.35

1.72 / 1.97

2.14 / 2.44

2.00 / 2.29

1.87 / 2.13

1.88 / 2.15

1.76 / 2.01

2.50 / 2.86

2.50 / 2.85

2.50 / 2.85

2.50 / 2.86

2.45 / 2.80

2.03 / 2.33

2.50 / 2.86

2.50 / 2.86

2.46 / 2.82

2.29 / 2.61

1.92 / 2.20

2.38 / 2.72

2.23 / 2.55

2.08 / 2.38

2.10 / 2.40

1.97 / 2.25

3.50 / 4.00

3.45 / 3.94

Unit C

2.20 / 2.53

2.20 / 2.51

2.20 / 2.50

2.20 / 2.52

2.20 / 2.51

2.20 / 2.52

1.86 / 2.12

2.50 / 2.85

2.50 / 2.86

2.50 / 2.86

2.50 / 2.85

2.50 / 2.86

2.07 / 2.37

3.50 / 3.99

3.50 / 3.99

3.50 / 4.00

3.27 / 3.73

2.74 / 3.13

4.86 / 5.56

4.55 / 5.19

4.24 / 4.85

5.12 / 5.85

4.80 / 5.49

2.50 / 2.86

2.50 / 2.85

2.50 / 2.85

2.50 / 2.86

2.45 / 2.80

2.03 / 2.33

3.50 / 4.01

3.50 / 4.00

3.45 / 3.94

3.20 / 3.66

2.69 / 3.08

4.76 / 5.44

4.46 / 5.10

4.17 / 4.76

5.03 / 5.75

4.72 / 5.39

3.50 / 4.00

3.45 / 3.94

Unit D

2.20 / 2.53

2.50 / 2.86

3.50 / 3.99

5.00 / 5.73

6.00 / 6.86

7.10 / 8.14

8.43 / 9.64

2.50 / 2.85

3.50 / 4.00

5.00 / 5.71

6.00 / 6.84

7.10 / 8.11

8.28 / 9.47

3.50 / 3.99

5.00 / 5.70

6.00 / 6.86

6.63 / 7.57

7.82 / 8.94

4.86 / 5.56

5.45 / 6.23

6.02 / 6.88

5.12 / 5.85

5.68 / 6.49

2.50 / 2.86

3.50 / 3.99

5.00 / 5.70

6.00 / 6.86

6.95 / 7.94

8.14 / 9.30

3.50 / 4.01

5.00 / 5.72

5.92 / 6.76

6.50 / 7.42

7.69 / 8.79

4.76 / 5.44

5.35 / 6.11

5.92 / 6.76

5.03 / 5.75

5.58 / 6.38

3.50 / 4.00

4.93 / 5.63

Indoor unitcombination

Cooling / Heating Capacity (kW)

22 + 35 + 35 + 60

22 + 35 + 35 + 71

22 + 35 + 50 + 50

22 + 35 + 50 + 60

22 + 35 + 50 + 71

22 + 35 + 60 + 60

22 + 50 + 50 + 50

22 + 50 + 50 + 60

25 + 25 + 25 + 25

25 + 25 + 25 + 35

25 + 25 + 25 + 50

25 + 25 + 25 + 60

25 + 25 + 25 + 71

25 + 25 + 25 + 100

25 + 25 + 35 + 35

25 + 25 + 35 + 50

25 + 25 + 35 + 60

25 + 25 + 35 + 71

25 + 25 + 35 + 100

25 + 25 + 50 + 50

25 + 25 + 50 + 60

25 + 25 + 50 + 71

25 + 25 + 60 + 60

25 + 25 + 60 + 71

25 + 35 + 35 + 35

25 + 35 + 35 + 50

25 + 35 + 35 + 60

25 + 35 + 35 + 71

25 + 35 + 50 + 50

25 + 35 + 50 + 60

25 + 35 + 50 + 71

25 + 35 + 60 + 60

25 + 50 + 50 + 50

25 + 50 + 50 + 60

35 + 35 + 35 + 35

35 + 35 + 35 + 50

35 + 35 + 35 + 60

35 + 35 + 35 + 71

35 + 35 + 50 + 50

35 + 35 + 50 + 60

35 + 50 + 50 + 50

Unit A

2.03 / 2.32

1.89 / 2.16

1.96 / 2.24

1.84 / 2.11

1.73 / 1.98

1.74 / 1.99

1.79 / 2.05

1.69 / 1.93

2.50 / 2.85

2.50 / 2.86

2.50 / 2.86

2.50 / 2.85

2.40 / 2.74

2.00 / 2.29

2.50 / 2.85

2.50 / 2.85

2.41 / 2.76

2.24 / 2.56

1.89 / 2.16

2.33 / 2.67

2.19 / 2.50

2.05 / 2.34

2.06 / 2.35

1.93 / 2.21

2.50 / 2.87

2.41 / 2.76

2.26 / 2.58

2.11 / 2.41

2.19 / 2.50

2.06 / 2.35

1.93 / 2.21

1.94 / 2.22

2.00 / 2.29

1.89 / 2.16

3.50 / 4.00

3.16 / 3.61

2.97 / 3.39

2.78 / 3.18

2.88 / 3.29

2.72 / 3.11

2.65 / 3.03

Unit B

3.22 / 3.68

3.01 / 3.44

3.12 / 3.57

2.93 / 3.35

2.75 / 3.15

2.77 / 3.16

4.07 / 4.65

3.85 / 4.40

2.50 / 2.85

2.50 / 2.86

2.50 / 2.86

2.50 / 2.85

2.40 / 2.74

2.00 / 2.29

2.50 / 2.85

2.50 / 2.85

2.41 / 2.76

2.24 / 2.56

1.89 / 2.16

2.33 / 2.67

2.19 / 2.50

2.05 / 2.34

2.06 / 2.35

1.93 / 2.21

3.50 / 4.01

3.38 / 3.86

3.16 / 3.61

2.95 / 3.37

3.06 / 3.50

2.88 / 3.29

2.71 / 3.09

2.72 / 3.11

4.00 / 4.57

3.78 / 4.32

3.50 / 4.00

3.16 / 3.61

2.97 / 3.39

2.78 / 3.18

2.88 / 3.29

2.72 / 3.11

3.78 / 4.32

Unit C

3.22 / 3.68

3.01 / 3.44

4.46 / 5.10

4.19 / 4.79

3.93 / 4.49

4.75 / 5.42

4.07 / 4.65

3.85 / 4.40

2.50 / 2.85

2.50 / 2.86

2.50 / 2.86

2.50 / 2.85

2.40 / 2.74

2.00 / 2.29

3.50 / 4.00

3.50 / 3.99

3.38 / 3.86

3.14 / 3.59

2.65 / 3.03

4.67 / 5.33

4.38 / 5.00

4.09 / 4.68

4.94 / 5.65

4.64 / 5.30

3.50 / 4.01

3.38 / 3.86

3.16 / 3.61

2.95 / 3.37

4.38 / 5.00

4.12 / 4.71

3.87 / 4.42

4.67 / 5.33

4.00 / 4.57

3.78 / 4.32

3.50 / 4.00

3.16 / 3.61

2.97 / 3.39

2.78 / 3.18

4.12 / 4.71

3.89 / 4.44

3.78 / 4.32

Unit D

5.53 / 6.32

6.10 / 6.97

4.46 / 5.10

5.03 / 5.75

5.58 / 6.38

4.75 / 5.42

4.07 / 4.65

4.62 / 5.27

2.50 / 2.85

3.50 / 4.01

5.00 / 5.72

6.00 / 6.84

6.81 / 7.78

8.00 / 9.14

3.50 / 4.00

5.00 / 5.70

5.79 / 6.62

6.37 / 7.28

7.57 / 8.65

4.67 / 5.33

5.25 / 6.00

5.81 / 6.64

4.94 / 5.65

5.49 / 6.28

3.50 / 4.01

4.83 / 5.52

5.42 / 6.19

5.99 / 6.84

4.38 / 5.00

4.94 / 5.65

5.49 / 6.28

4.67 / 5.33

4.00 / 4.57

4.54 / 5.19

3.50 / 4.00

4.52 / 5.16

5.09 / 5.82

5.65 / 6.45

4.12 / 4.71

4.67 / 5.33

3.78 / 4.32

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 48

Page 29: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

22 + 25 + 25 + 25 + 25 + 35

22 + 25 + 25 + 25 + 25 + 50

22 + 25 + 25 + 25 + 25 + 60

22 + 25 + 25 + 25 + 35 + 35

22 + 25 + 25 + 25 + 35 + 50

22 + 25 + 25 + 35 + 35 + 35

25 + 25 + 25 + 25 + 25 + 25

25 + 25 + 25 + 25 + 25 + 35

25 + 25 + 25 + 25 + 25 + 50

25 + 25 + 25 + 25 + 25 + 60

25 + 25 + 25 + 25 + 35 + 35

25 + 25 + 25 + 25 + 35 + 50

25 + 25 + 25 + 35 + 35 + 35

7 ROOMS22 + 22 + 22 + 22 + 22 + 22 + 22

22 + 22 + 22 + 22 + 22 + 22 + 25

22 + 22 + 22 + 22 + 22 + 22 + 35

22 + 22 + 22 + 22 + 22 + 22 + 50

22 + 22 + 22 + 22 + 22 + 25 + 25

22 + 22 + 22 + 22 + 22 + 25 + 35

22 + 22 + 22 + 22 + 22 + 25 + 50

22 + 22 + 22 + 22 + 22 + 35 + 35

22 + 22 + 22 + 22 + 25 + 25 + 25

22 + 22 + 22 + 22 + 25 + 25 + 35

22 + 22 + 22 + 22 + 25 + 35 + 35

22 + 22 + 22 + 25 + 25 + 25 + 25

22 + 22 + 22 + 25 + 25 + 25 + 35

22 + 22 + 25 + 25 + 25 + 25 + 25

22 + 22 + 25 + 25 + 25 + 25 + 35

22 + 25 + 25 + 25 + 25 + 25 + 25

22 + 25 + 25 + 25 + 25 + 25 + 35

25 + 25 + 25 + 25 + 25 + 25 + 25

25 + 25 + 25 + 25 + 25 + 25 + 35

8 ROOMS22 + 22 + 22 + 22 + 22 + 22 + 22 + 22

22 + 22 + 22 + 22 + 22 + 22 + 22 + 25

22 + 22 + 22 + 22 + 22 + 22 + 25 + 25

22 + 22 + 22 + 22 + 22 + 25 + 25 + 25

Unit A

1.96 / 2.24

1.79 / 2.05

1.69 / 1.93

1.84 / 2.11

1.69 / 1.93

1.74 / 1.99

2.33 / 2.67

2.19 / 2.50

2.00 / 2.29

1.89 / 2.16

2.06 / 2.35

1.89 / 2.16

1.94 / 2.22

2.00 / 2.29

1.96 / 2.24

1.84 / 2.11

1.69 / 1.93

1.93 / 2.20

1.81 / 2.07

1.66 / 1.90

1.71 / 1.96

1.89 / 2.16

1.78 / 2.03

1.68 / 1.92

1.86 / 2.12

1.75 / 2.00

1.82 / 2.08

1.72 / 1.97

1.79 / 2.05

1.69 / 1.93

2.00 / 2.29

1.89 / 2.16

1.75 / 2.00

1.72 / 1.97

1.69 / 1.93

1.66 / 1.90

Unit B

2.23 / 2.55

2.03 / 2.33

1.92 / 2.20

2.10 / 2.40

1.92 / 2.20

1.98 / 2.26

2.33 / 2.67

2.19 / 2.50

2.00 / 2.29

1.89 / 2.16

2.06 / 2.35

1.89 / 2.16

1.94 / 2.22

2.00 / 2.29

1.96 / 2.24

1.84 / 2.11

1.69 / 1.93

1.93 / 2.20

1.81 / 2.07

1.66 / 1.90

1.71 / 1.96

1.89 / 2.16

1.78 / 2.03

1.68 / 1.92

1.86 / 2.12

1.75 / 2.00

1.82 / 2.08

1.72 / 1.97

2.03 / 2.33

1.92 / 2.20

2.00 / 2.29

1.89 / 2.16

1.75 / 2.00

1.72 / 1.97

1.69 / 1.93

1.66 / 1.90

Unit C

2.23 / 2.55

2.03 / 2.33

1.92 / 2.20

2.10 / 2.40

1.92 / 2.20

1.98 / 2.26

2.33 / 2.67

2.19 / 2.50

2.00 / 2.29

1.89 / 2.16

2.06 / 2.35

1.89 / 2.16

1.94 / 2.22

2.00 / 2.29

1.96 / 2.24

1.84 / 2.11

1.69 / 1.93

1.93 / 2.20

1.81 / 2.07

1.66 / 1.90

1.71 / 1.96

1.89 / 2.16

1.78 / 2.03

1.68 / 1.92

1.86 / 2.12

1.75 / 2.00

2.07 / 2.37

1.96 / 2.23

2.03 / 2.33

1.92 / 2.20

2.00 / 2.29

1.89 / 2.16

1.75 / 2.00

1.72 / 1.97

1.69 / 1.93

1.66 / 1.90

Unit D

2.23 / 2.55

2.03 / 2.33

1.92 / 2.20

2.10 / 2.40

1.92 / 2.20

2.77 / 3.16

2.33 / 2.67

2.19 / 2.50

2.00 / 2.29

1.89 / 2.16

2.06 / 2.35

1.89 / 2.16

2.72 / 3.11

2.00 / 2.29

1.96 / 2.24

1.84 / 2.11

1.69 / 1.93

1.93 / 2.20

1.81 / 2.07

1.66 / 1.90

1.71 / 1.96

1.89 / 2.16

1.78 / 2.03

1.68 / 1.92

2.11 / 2.41

1.99 / 2.27

2.07 / 2.37

1.96 / 2.23

2.03 / 2.33

1.92 / 2.20

2.00 / 2.29

1.89 / 2.16

1.75 / 2.00

1.72 / 1.97

1.69 / 1.93

1.66 / 1.90

Unit E

2.23 / 2.55

2.03 / 2.33

1.92 / 2.20

2.93 / 3.35

2.69 / 3.08

2.77 / 3.16

2.33 / 2.67

2.19 / 2.50

2.00 / 2.29

1.89 / 2.16

2.88 / 3.29

2.65 / 3.03

2.72 / 3.11

2.00 / 2.29

1.96 / 2.24

1.84 / 2.11

1.69 / 1.93

1.93 / 2.20

1.81 / 2.07

1.66 / 1.90

1.71 / 1.96

2.15 / 2.45

2.02 / 2.31

1.91 / 2.19

2.11 / 2.41

1.99 / 2.27

2.07 / 2.37

1.96 / 2.23

2.03 / 2.33

1.92 / 2.20

2.00 / 2.29

1.89 / 2.16

1.75 / 2.00

1.72 / 1.97

1.69 / 1.93

1.66 / 1.90

Unit F

3.12 / 3.57

4.07 / 4.65

4.62 / 5.27

2.93 / 3.35

3.85 / 4.40

2.77 / 3.16

2.33 / 2.67

3.06 / 3.50

4.00 / 4.57

4.54 / 5.19

2.88 / 3.29

3.78 / 4.32

2.72 / 3.11

2.00 / 2.29

1.96 / 2.24

1.84 / 2.11

1.69 / 1.93

2.19 / 2.50

2.06 / 2.35

1.89 / 2.16

2.72 / 3.11

2.15 / 2.45

2.02 / 2.31

2.68 / 3.06

2.11 / 2.41

1.99 / 2.27

2.07 / 2.37

1.96 / 2.23

2.03 / 2.33

1.92 / 2.20

2.00 / 2.29

1.89 / 2.16

1.75 / 2.00

1.72 / 1.97

1.69 / 1.93

1.89 / 2.16

Unit G

2.00 / 2.29

2.23 / 2.55

2.93 / 3.35

3.85 / 4.40

2.19 / 2.50

2.88 / 3.29

3.78 / 4.32

2.72 / 3.11

2.15 / 2.45

2.83 / 3.24

2.68 / 3.06

2.11 / 2.41

2.78 / 3.18

2.07 / 2.37

2.74 / 3.13

2.03 / 2.33

2.69 / 3.08

2.00 / 2.29

2.65 / 3.03

1.75 / 2.00

1.72 / 1.97

1.92 / 2.20

1.89 / 2.16

Unit H

1.75 / 2.00

1.96 / 2.23

1.92 / 2.20

1.89 / 2.16

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 51

25 + 25 + 25 + 25 + 25

25 + 25 + 25 + 25 + 35

25 + 25 + 25 + 25 + 50

25 + 25 + 25 + 25 + 60

25 + 25 + 25 + 25 + 71

25 + 25 + 25 + 35 + 35

25 + 25 + 25 + 35 + 50

25 + 25 + 25 + 35 + 60

25 + 25 + 25 + 35 + 71

25 + 25 + 25 + 50 + 50

25 + 25 + 25 + 50 + 60

25 + 25 + 35 + 35 + 35

25 + 25 + 35 + 35 + 50

25 + 25 + 35 + 35 + 60

25 + 25 + 35 + 50 + 50

25 + 35 + 35 + 35 + 35

25 + 35 + 35 + 35 + 50

35 + 35 + 35 + 35 + 35

6 ROOMS22 + 22 + 22 + 22 + 22 + 22

22 + 22 + 22 + 22 + 22 + 25

22 + 22 + 22 + 22 + 22 + 35

22 + 22 + 22 + 22 + 22 + 50

22 + 22 + 22 + 22 + 22 + 60

22 + 22 + 22 + 22 + 22 + 71

22 + 22 + 22 + 22 + 25 + 25

22 + 22 + 22 + 22 + 25 + 35

22 + 22 + 22 + 22 + 25 + 50

22 + 22 + 22 + 22 + 25 + 60

22 + 22 + 22 + 22 + 25 + 71

22 + 22 + 22 + 22 + 35 + 35

22 + 22 + 22 + 22 + 35 + 50

22 + 22 + 22 + 22 + 35 + 60

22 + 22 + 22 + 25 + 25 + 25

22 + 22 + 22 + 25 + 25 + 35

22 + 22 + 22 + 25 + 25 + 50

22 + 22 + 22 + 25 + 25 + 60

22 + 22 + 22 + 25 + 35 + 35

22 + 22 + 22 + 25 + 35 + 50

22 + 22 + 22 + 35 + 35 + 35

22 + 22 + 25 + 25 + 25 + 25

22 + 22 + 25 + 25 + 25 + 35

22 + 22 + 25 + 25 + 25 + 50

22 + 22 + 25 + 25 + 25 + 60

22 + 22 + 25 + 25 + 35 + 35

22 + 22 + 25 + 25 + 35 + 50

22 + 22 + 25 + 35 + 35 + 35

22 + 22 + 35 + 35 + 35 + 35

22 + 25 + 25 + 25 + 25 + 25

Unit A

2.50 / 2.86

2.50 / 2.85

2.33 / 2.67

2.19 / 2.50

2.05 / 2.34

2.41 / 2.76

2.19 / 2.50

2.06 / 2.35

1.93 / 2.21

2.00 / 2.29

1.89 / 2.16

2.26 / 2.58

2.06 / 2.35

1.94 / 2.22

1.89 / 2.16

2.12 / 2.42

1.94 / 2.22

2.80 / 3.20

2.20 / 2.52

2.20 / 2.51

2.12 / 2.43

1.93 / 2.20

1.81 / 2.07

1.70 / 1.94

2.20 / 2.52

2.08 / 2.38

1.89 / 2.16

1.78 / 2.03

1.67 / 1.91

1.95 / 2.23

1.78 / 2.03

1.68 / 1.92

2.18 / 2.50

2.04 / 2.33

1.86 / 2.12

1.75 / 2.00

1.91 / 2.19

1.75 / 2.00

1.80 / 2.06

2.14 / 2.44

2.00 / 2.29

1.82 / 2.08

1.72 / 1.97

1.88 / 2.15

1.72 / 1.97

1.70 / 2.02

1.67 / 1.91

2.10 / 2.39

Unit B

2.50 / 2.86

2.50 / 2.85

2.33 / 2.67

2.19 / 2.50

2.05 / 2.34

2.41 / 2.76

2.19 / 2.50

2.06 / 2.35

1.93 / 2.21

2.00 / 2.29

1.89 / 2.16

2.26 / 2.58

2.06 / 2.35

1.94 / 2.22

1.89 / 2.16

2.97 / 3.39

2.72 / 3.11

2.80 / 3.20

2.20 / 2.52

2.20 / 2.51

2.12 / 2.43

1.93 / 2.20

1.81 / 2.07

1.70 / 1.94

2.20 / 2.52

2.08 / 2.38

1.89 / 2.16

1.78 / 2.03

1.67 / 1.91

1.95 / 2.23

1.78 / 2.03

1.68 / 1.92

2.18 / 2.50

2.04 / 2.33

1.86 / 2.12

1.75 / 2.00

1.91 / 2.19

1.75 / 2.00

1.80 / 2.06

2.14 / 2.44

2.00 / 2.29

1.82 / 2.08

1.72 / 1.97

1.88 / 2.15

1.72 / 1.97

1.70 / 2.02

1.67 / 1.91

2.38 / 2.72

Unit C

2.50 / 2.86

2.50 / 2.85

2.33 / 2.67

2.19 / 2.50

2.05 / 2.34

2.41 / 2.76

2.19 / 2.50

2.06 / 2.35

1.93 / 2.21

2.00 / 2.29

1.89 / 2.16

3.16 / 3.61

2.88 / 3.29

2.72 / 3.11

2.65 / 3.03

2.97 / 3.39

2.72 / 3.11

2.80 / 3.20

2.20 / 2.52

2.20 / 2.51

2.12 / 2.43

1.93 / 2.20

1.81 / 2.07

1.70 / 1.94

2.20 / 2.52

2.08 / 2.38

1.89 / 2.16

1.78 / 2.03

1.67 / 1.91

1.95 / 2.23

1.78 / 2.03

1.68 / 1.92

2.18 / 2.50

2.04 / 2.33

1.86 / 2.12

1.75 / 2.00

1.91 / 2.19

1.75 / 2.00

1.80 / 2.06

2.43 / 2.78

2.27 / 2.60

2.07 / 2.37

1.96 / 2.23

2.13 / 2.44

1.96 / 2.23

2.00 / 2.30

2.66 / 3.04

2.38 / 2.72

Unit D

2.50 / 2.86

2.50 / 2.85

2.33 / 2.67

2.19 / 2.50

2.05 / 2.34

3.38 / 3.86

3.06 / 3.50

2.88 / 3.29

2.71 / 3.09

4.00 / 4.57

3.78 / 4.32

3.16 / 3.61

2.88 / 3.29

2.72 / 3.11

3.78 / 4.32

2.97 / 3.39

2.72 / 3.11

2.80 / 3.20

2.20 / 2.52

2.20 / 2.51

2.12 / 2.43

1.93 / 2.20

1.81 / 2.07

1.70 / 1.94

2.20 / 2.52

2.08 / 2.38

1.89 / 2.16

1.78 / 2.03

1.67 / 1.91

1.95 / 2.23

1.78 / 2.03

1.68 / 1.92

2.48 / 2.84

2.32 / 2.65

2.11 / 2.41

1.99 / 2.27

2.17 / 2.48

1.99 / 2.27

2.87 / 3.27

2.43 / 2.78

2.27 / 2.60

2.07 / 2.37

1.96 / 2.23

2.13 / 2.44

1.96 / 2.23

2.82 / 3.22

2.66 / 3.04

2.38 / 2.72

Unit E

2.50 / 2.86

3.50 / 3.99

4.67 / 5.33

5.25 / 6.00

5.81 / 6.64

3.38 / 3.86

4.38 / 5.00

4.94 / 5.65

5.49 / 6.28

4.00 / 4.57

4.54 / 5.19

3.16 / 3.61

4.12 / 4.71

4.67 / 5.33

3.78 / 4.32

2.97 / 3.39

3.89 / 4.44

2.80 / 3.20

2.20 / 2.52

2.20 / 2.51

2.12 / 2.43

1.93 / 2.20

1.81 / 2.07

1.70 / 1.94

2.50 / 2.86

2.36 / 2.70

2.15 / 2.45

2.02 / 2.31

1.90 / 2.17

3.10 / 3.54

2.83 / 3.24

2.68 / 3.06

2.48 / 2.84

2.32 / 2.65

2.11 / 2.41

1.99 / 2.27

3.04 / 3.48

2.78 / 3.18

2.87 / 3.27

2.43 / 2.78

2.27 / 2.60

2.07 / 2.37

1.96 / 2.23

2.99 / 3.41

2.74 / 3.13

2.82 / 3.22

2.66 / 3.04

2.38 / 2.72

Unit F

2.20 / 2.52

2.50 / 2.85

3.38 / 3.86

4.38 / 5.00

4.94 / 5.65

5.49 / 6.28

2.50 / 2.86

3.31 / 3.78

4.29 / 4.91

4.86 / 5.55

5.40 / 6.17

3.10 / 3.54

4.05 / 4.62

4.59 / 5.25

2.48 / 2.84

3.25 / 3.71

4.22 / 4.82

4.77 / 5.45

3.04 / 3.48

3.98 / 4.55

2.87 / 3.27

2.43 / 2.78

3.18 / 3.64

4.14 / 4.73

4.69 / 5.36

2.99 / 3.41

3.91 / 4.47

2.82 / 3.22

2.66 / 3.04

2.38 / 2.72

Unit G Unit H

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 50

Page 30: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

1 ROOM22

25

35

50

60

71

100

2 ROOMS22 + 22

22 + 25

22 + 35

22 + 50

22 + 60

22 + 71

22 + 100

25 + 25

25 + 35

25 + 50

25 + 60

25 + 71

25 + 100

35 + 35

35 + 50

35 + 60

35 + 71

35 + 100

50 + 50

50 + 60

50 + 71

50 + 100

60 + 60

60 + 71

60 + 100

71 + 71

71 + 100

100 + 100

3 ROOMS22 + 22 + 22

22 + 22 + 25

22 + 22 + 35

22 + 22 + 50

22 + 22 + 60

22 + 22 + 71

22 + 22 + 100

Unit A

2.20 / 3.30

2.50 / 3.60

3.50 / 4.00

5.00 / 7.20

6.00 / 7.90

7.10 / 8.60

10.00 / 11.20

2.20 / 2.55

2.20 / 2.57

2.20 / 2.55

2.20 / 2.57

2.20 / 2.55

2.20 / 2.55

2.20 / 2.56

2.50 / 2.90

2.50 / 2.92

2.50 / 2.90

2.50 / 2.91

2.50 / 2.89

2.50 / 2.90

3.50 / 4.05

3.50 / 4.08

3.50 / 4.05

3.50 / 4.06

3.50 / 4.07

5.00 / 5.80

5.00 / 5.82

5.00 / 5.83

4.67 / 6.00

6.00 / 6.95

6.00 / 6.96

5.25 / 6.75

7.00 / 9.00

5.81 / 7.47

7.00 / 9.00

2.20 / 2.57

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.20 / 2.56

2.20 / 2.56

2.14 / 2.75

Unit B

2.20 / 2.55

2.50 / 2.93

3.50 / 4.05

5.00 / 5.83

6.00 / 6.95

7.10 / 8.25

10.00 / 11.64

2.50 / 2.90

3.50 / 4.08

5.00 / 5.80

6.00 / 6.99

7.10 / 8.21

10.00 / 11.60

3.50 / 4.05

5.00 / 5.82

6.00 / 6.95

7.10 / 8.24

10.00 / 11.63

5.00 / 5.80

6.00 / 6.98

7.10 / 8.27

9.33 / 12.00

6.00 / 6.95

7.10 / 8.24

8.75 / 11.25

7.00 / 9.00

8.19 / 10.53

7.00 / 9.00

2.20 / 2.57

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.20 / 2.56

2.20 / 2.56

2.14 / 2.75

Unit C

­­­­­

2.20 / 2.57

2.50 / 2.90

3.50 / 4.08

5.00 / 5.80

6.00 / 6.98

7.10 / 8.27

9.72 / 12.50

Unit D

Indoor unitcombination

Cooling / Heating Capacity (kW)

MXZ-8B160YA1Outdoor Unit Up to 8 Indoor Units

22 + 25 + 25

22 + 25 + 35

22 + 25 + 50

22 + 25 + 60

22 + 25 + 71

22 + 25 + 100

22 + 35 + 35

22 + 35 + 50

22 + 35 + 60

22 + 35 + 71

22 + 35 + 100

22 + 50 + 50

22 + 50 + 60

22 + 50 + 71

22 + 50 + 100

22 + 60 + 60

22 + 60 + 71

22 + 60 + 100

22 + 71 + 71

22 + 71 + 100

25 + 25 + 25

25 + 25 + 35

25 + 25 + 50

25 + 25 + 60

25 + 25 + 71

25 + 25 + 100

25 + 35 + 35

25 + 35 + 50

25 + 35 + 60

25 + 35 + 71

25 + 35 + 100

25 + 50 + 50

25 + 50 + 60

25 + 50 + 71

25 + 50 + 100

25 + 60 + 60

25 + 60 + 71

25 + 60 + 100

25 + 71 + 71

25 + 71 + 100

35 + 35 + 35

35 + 35 + 50

35 + 35 + 60

35 + 35 + 71

35 + 35 + 100

35 + 50 + 50

35 + 50 + 60

35 + 50 + 71

35 + 50 + 100

35 + 60 + 60

Unit D

Indoor unitcombination

Cooling / Heating Capacity (kW)

35 + 60 + 71

35 + 60 + 100

35 + 71 + 71

50 + 50 + 50

50 + 50 + 60

50 + 50 + 71

50 + 50 + 100

50 + 60 + 60

50 + 60 + 71

50 + 71 + 71

60 + 60 + 60

60 + 60 + 71

60 + 71 + 71

4 ROOMS22 + 22 + 22 + 22

22 + 22 + 22 + 25

22 + 22 + 22 + 35

22 + 22 + 22 + 50

22 + 22 + 22 + 60

22 + 22 + 22 + 71

22 + 22 + 22 + 100

22 + 22 + 25 + 25

22 + 22 + 25 + 35

22 + 22 + 25 + 50

22 + 22 + 25 + 60

22 + 22 + 25 + 71

22 + 22 + 25 + 100

22 + 22 + 35 + 35

22 + 22 + 35 + 50

22 + 22 + 35 + 60

22 + 22 + 35 + 71

22 + 22 + 35 + 100

22 + 22 + 50 + 50

22 + 22 + 50 + 60

22 + 22 + 50 + 71

22 + 22 + 50 + 100

22 + 22 + 60 + 60

22 + 22 + 60 + 71

22 + 22 + 71 + 71

22 + 25 + 25 + 25

22 + 25 + 25 + 35

22 + 25 + 25 + 50

22 + 25 + 25 + 60

22 + 25 + 25 + 71

22 + 25 + 25 + 100

22 + 25 + 35 + 35

22 + 25 + 35 + 50

22 + 25 + 35 + 60

Unit A

2.95 / 3.80

2.51 / 3.23

2.77 / 3.56

4.67 / 6.00

4.38 / 5.63

4.09 / 5.26

3.50 / 4.50

4.12 / 5.29

3.87 / 4.97

3.65 / 4.69

4.67 / 6.00

4.40 / 5.65

4.16 / 5.35

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.20 / 2.55

1.86 / 2.39

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.20 / 2.56

2.20 / 2.83

1.82 / 2.34

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.05 / 2.64

1.72 / 2.21

2.14 / 2.75

2.00 / 2.57

1.87 / 2.40

1.59 / 2.04

1.88 / 2.41

1.76 / 2.26

1.66 / 2.13

2.20 / 2.56

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.15 / 2.77

1.79 / 2.30

2.20 / 2.56

2.20 / 2.55

2.17 / 2.79

Unit B

5.06 / 6.51

4.31 / 5.54

5.62 / 7.22

4.67 / 6.00

4.38 / 5.63

4.09 / 5.26

3.50 / 4.50

4.94 / 6.35

4.64 / 5.97

5.18 / 6.66

4.67 / 6.00

4.40 / 5.65

4.92 / 6.33

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.20 / 2.55

1.86 / 2.39

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.20 / 2.56

2.20 / 2.83

1.82 / 2.34

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.05 / 2.64

1.72 / 2.21

2.14 / 2.75

2.00 / 2.57

1.87 / 2.40

1.59 / 2.04

1.88 / 2.41

1.76 / 2.26

1.66 / 2.13

2.50 / 2.91

2.50 / 2.90

2.50 / 2.91

2.50 / 2.90

2.45 / 3.15

2.03 / 2.62

2.50 / 2.91

2.50 / 2.90

2.46 / 3.17

Unit C

5.99 / 7.70

7.18 / 9.23

5.62 / 7.22

4.67 / 6.00

5.25 / 6.75

5.81 / 7.47

7.00 / 9.00

4.94 / 6.35

5.49 / 7.06

5.18 / 6.66

4.67 / 6.00

5.20 / 6.69

4.92 / 6.33

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.20 / 2.55

1.86 / 2.39

2.50 / 2.90

2.50 / 2.91

2.50 / 2.90

2.50 / 2.91

2.50 / 3.21

2.07 / 2.66

3.50 / 4.05

3.50 / 4.07

3.50 / 4.05

3.27 / 4.20

2.74 / 3.52

4.86 / 6.25

4.55 / 5.84

4.24 / 5.45

3.61 / 4.64

5.12 / 6.59

4.80 / 6.17

5.34 / 6.87

2.50 / 2.91

2.50 / 2.90

2.50 / 2.91

2.50 / 2.90

2.45 / 3.15

2.03 / 2.62

3.50 / 4.07

3.50 / 4.06

3.45 / 4.44

Unit D

2.20 / 2.55

2.50 / 2.91

3.50 / 4.05

5.00 / 5.82

6.00 / 6.95

7.10 / 8.24

8.43 / 10.84

2.50 / 2.90

3.50 / 4.07

5.00 / 5.80

6.00 / 6.98

7.10 / 9.13

8.28 / 10.65

3.50 / 4.05

5.00 / 5.81

6.00 / 6.95

6.63 / 8.52

7.82 / 10.06

4.86 / 6.25

5.45 / 7.01

6.02 / 7.75

7.22 / 9.28

5.12 / 6.59

5.68 / 7.30

5.34 / 6.87

2.50 / 2.91

3.50 / 4.06

5.00 / 5.82

6.00 / 6.95

6.95 / 8.94

8.14 / 10.47

3.50 / 4.07

5.00 / 5.80

5.92 / 7.61

Indoor unitcombination

Cooling / Heating Capacity (kW)

22 + 25 + 35 + 71

22 + 25 + 35 + 100

22 + 25 + 50 + 50

22 + 25 + 50 + 60

22 + 25 + 50 + 71

22 + 25 + 50 + 100

22 + 25 + 60 + 60

22 + 25 + 60 + 71

22 + 25 + 71 + 71

22 + 35 + 35 + 35

22 + 35 + 35 + 50

22 + 35 + 35 + 60

22 + 35 + 35 + 71

22 + 35 + 35 + 100

22 + 35 + 50 + 50

22 + 35 + 50 + 60

22 + 35 + 50 + 71

22 + 35 + 60 + 60

22 + 35 + 60 + 71

22 + 35 + 71 + 71

22 + 50 + 50 + 50

22 + 50 + 50 + 60

22 + 50 + 50 + 71

22 + 50 + 60 + 60

22 + 60 + 60 + 60

25 + 25 + 25 + 25

25 + 25 + 25 + 35

25 + 25 + 25 + 50

25 + 25 + 25 + 60

25 + 25 + 25 + 71

25 + 25 + 25 + 100

25 + 25 + 35 + 35

25 + 25 + 35 + 50

25 + 25 + 35 + 60

25 + 25 + 35 + 71

25 + 25 + 35 + 100

25 + 25 + 50 + 50

25 + 25 + 50 + 60

25 + 25 + 50 + 71

25 + 25 + 50 + 100

25 + 25 + 60 + 60

25 + 25 + 60 + 71

25 + 25 + 71 + 71

25 + 35 + 35 + 35

25 + 35 + 35 + 50

25 + 35 + 35 + 60

25 + 35 + 35 + 71

25 + 35 + 35 + 100

25 + 35 + 50 + 50

25 + 35 + 50 + 60

Unit A

2.01 / 2.59

1.69 / 2.18

2.10 / 2.69

1.96 / 2.52

1.83 / 2.36

1.56 / 2.01

1.84 / 2.37

1.73 / 2.22

1.63 / 2.10

2.20 / 2.55

2.17 / 2.79

2.03 / 2.61

1.89 / 2.43

1.60 / 2.06

1.96 / 2.52

1.84 / 2.37

1.73 / 2.22

1.74 / 2.24

1.64 / 2.11

1.55 / 1.99

1.79 / 2.30

1.69 / 2.18

1.60 / 2.05

1.60 / 2.06

1.52 / 1.96

2.50 / 2.90

2.50 / 2.91

2.50 / 2.90

2.50 / 2.91

2.40 / 3.08

2.00 / 2.57

2.50 / 2.90

2.50 / 2.91

2.41 / 3.10

2.24 / 2.88

1.89 / 2.43

2.33 / 3.00

2.19 / 2.81

2.05 / 2.63

1.75 / 2.25

2.06 / 2.65

1.93 / 2.49

1.82 / 2.34

2.50 / 2.90

2.41 / 3.10

2.26 / 2.90

2.11 / 2.71

1.79 / 2.31

2.19 / 2.81

2.06 / 2.65

Unit B

2.29 / 2.94

1.92 / 2.47

2.38 / 3.06

2.23 / 2.87

2.08 / 2.68

1.78 / 2.28

2.10 / 2.69

1.97 / 2.53

1.85 / 2.38

3.50 / 4.05

3.45 / 4.44

3.22 / 4.14

3.01 / 3.87

2.55 / 3.28

3.12 / 4.01

2.93 / 3.77

2.75 / 3.54

2.77 / 3.56

2.61 / 3.35

2.46 / 3.17

4.07 / 5.23

3.85 / 4.95

3.63 / 4.66

3.65 / 4.69

4.16 / 5.35

2.50 / 2.90

2.50 / 2.91

2.50 / 2.90

2.50 / 2.91

2.40 / 3.08

2.00 / 2.57

2.50 / 2.90

2.50 / 2.91

2.41 / 3.10

2.24 / 2.88

1.89 / 2.43

2.33 / 3.00

2.19 / 2.81

2.05 / 2.63

1.75 / 2.25

2.06 / 2.65

1.93 / 2.49

1.82 / 2.34

3.50 / 4.07

3.38 / 4.34

3.16 / 4.06

2.95 / 3.80

2.51 / 3.23

3.06 / 3.94

2.88 / 3.71

Unit C

3.20 / 4.12

2.69 / 3.46

4.76 / 6.12

4.46 / 5.73

4.17 / 5.36

3.55 / 4.57

5.03 / 6.47

4.72 / 6.07

5.26 / 6.76

3.50 / 4.05

3.45 / 4.44

3.22 / 4.14

3.01 / 3.87

2.55 / 3.28

4.46 / 5.73

4.19 / 5.39

3.93 / 5.06

4.75 / 6.10

4.47 / 5.74

4.99 / 6.42

4.07 / 5.23

3.85 / 4.95

3.63 / 4.66

4.38 / 5.63

4.16 / 5.35

2.50 / 2.90

2.50 / 2.91

2.50 / 2.90

2.50 / 2.91

2.40 / 3.08

2.00 / 2.57

3.50 / 4.05

3.50 / 4.07

3.38 / 4.34

3.14 / 4.04

2.65 / 3.41

4.67 / 6.00

4.38 / 5.63

4.09 / 5.26

3.50 / 4.50

4.94 / 6.35

4.64 / 5.97

5.18 / 6.66

3.50 / 4.07

3.38 / 4.34

3.16 / 4.06

2.95 / 3.80

2.51 / 3.23

4.38 / 5.63

4.12 / 5.29

Unit D

6.50 / 8.35

7.69 / 9.89

4.76 / 6.12

5.35 / 6.88

5.92 / 7.61

7.11 / 9.14

5.03 / 6.47

5.58 / 7.18

5.26 / 6.76

3.50 / 4.05

4.93 / 6.34

5.53 / 7.11

6.10 / 7.84

7.29 / 9.38

4.46 / 5.73

5.03 / 6.47

5.58 / 7.18

4.75 / 6.10

5.29 / 6.80

4.99 / 6.42

4.07 / 5.23

4.62 / 5.93

5.15 / 6.62

4.38 / 5.63

4.16 / 5.35

2.50 / 2.90

3.50 / 4.07

5.00 / 5.80

6.00 / 6.98

6.81 / 8.75

8.00 / 10.29

3.50 / 4.05

5.00 / 5.81

5.79 / 7.45

6.37 / 8.19

7.57 / 9.73

4.67 / 6.00

5.25 / 6.75

5.81 / 7.47

7.00 / 9.00

4.94 / 6.35

5.49 / 7.06

5.18 / 6.66

3.50 / 4.07

4.83 / 6.21

5.42 / 6.97

5.99 / 7.70

7.18 / 9.23

4.38 / 5.63

4.94 / 6.35

Indoor unitcombination

Cooling / Heating Capacity (kW)

Unit A

2.20 / 2.57

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.20 / 2.55

2.10 / 2.69

2.20 / 2.56

2.20 / 2.55

2.20 / 2.56

2.20 / 2.56

1.96 / 2.52

2.20 / 2.56

2.20 / 2.55

2.15 / 2.77

1.79 / 2.30

2.17 / 2.79

2.01 / 2.59

1.69 / 2.18

1.88 / 2.41

1.60 / 2.05

2.50 / 2.90

2.50 / 2.91

2.50 / 2.90

2.50 / 2.91

2.50 / 2.91

2.33 / 3.00

2.50 / 2.89

2.50 / 2.91

2.50 / 2.90

2.50 /2.90

2.19 / 2.81

2.50 / 2.90

2.50 / 2.91

2.40 / 3.08

2.00 / 2.57

2.41 / 3.10

2.24 / 2.88

1.89 / 2.43

2.10 / 2.69

1.79 / 2.30

3.50 / 4.07

3.50 / 4.05

3.50 / 4.07

3.48 / 4.47

2.88 / 3.71

3.50 / 4.07

3.38 / 4.34

3.14 / 4.04

2.65 / 3.41

3.16 / 4.06

Unit B

2.50 / 2.92

2.50 / 2.90

2.50 / 2.91

2.50 / 2.90

2.50 / 2.90

2.38 / 3.06

3.50 / 4.07

3.50 / 4.06

3.50 / 4.07

3.50 / 4.07

3.12 / 4.01

5.00 / 5.82

5.00 / 5.80

4.90 / 6.29

4.07 / 5.23

5.92 / 7.61

5.49 / 7.06

4.62 / 5.93

6.06 / 7.79

5.15 / 6.62

2.50 / 2.90

2.50 / 2.91

2.50 / 2.90

2.50 / 2.91

2.50 / 2.91

2.33 / 3.00

3.50 / 4.05

3.50 / 4.07

3.50 / 4.05

3.50 / 4.06

3.06 / 3.94

5.00 / 5.80

5.00 / 5.81

4.79 / 6.16

4.00 / 5.14

5.79 / 7.45

5.38 / 6.92

4.54 / 5.84

5.95 / 7.65

5.07 / 6.52

3.50 / 4.07

3.50 / 4.05

3.50 / 4.07

3.48 / 4.47

2.88 / 3.71

5.00 / 5.81

4.83 / 6.21

4.49 / 5.77

3.78 / 4.86

5.42 / 6.97

Unit C

2.50 / 2.92

3.50 / 4.05

5.00 / 5.82

6.00 / 6.95

7.10 / 8.24

9.52 / 12.24

3.50 / 4.07

5.00 / 5.79

6.00 / 6.97

7.10 / 8.26

8.92 / 11.46

5.00 / 5.82

6.00 / 6.95

6.95 / 8.94

8.14 / 10.47

5.92 / 7.61

6.50 / 8.35

7.69 / 9.89

6.06 / 7.79

7.25 / 9.33

2.50 / 2.90

3.50 / 4.08

5.00 / 5.80

6.00 / 6.98

7.10 / 8.27

9.33 / 12.00

3.50 / 4.05

5.00 / 5.82

6.00 / 6.95

7.10 / 8.24

8.75 / 11.25

5.00 / 5.80

6.00 / 6.98

6.81 / 8.75

8.00 / 10.29

5.79 / 7.45

6.37 / 8.19

7.57 / 9.73

5.95 / 7.65

7.14 / 9.18

3.50 / 4.07

5.00 / 5.79

6.00 / 6.97

7.05 / 9.06

8.24 / 10.59

5.00 / 5.81

5.79 / 7.45

6.37 / 8.19

7.57 / 9.73

5.42 / 6.97

Page 53Page 52

Page 31: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

25 + 35 + 50 + 71

25 + 35 + 60 + 60

25 + 35 + 60 + 71

25 + 35 + 71 + 71

25 + 50 + 50 + 50

25 + 50 + 50 + 60

25 + 50 + 50 + 71

25 + 50 + 60 + 60

35 + 35 + 35 + 35

35 + 35 + 35 + 50

35 + 35 + 35 + 60

35 + 35 + 35 + 71

35 + 35 + 50 + 50

35 + 35 + 50 + 60

35 + 35 + 50 + 71

35 + 35 + 60 + 60

35 + 35 + 60 + 71

35 + 50 + 50 + 50

35 + 50 + 50 + 60

50 + 50 + 50 + 50

5 ROOMS22 + 22 + 22 + 22 + 22

22 + 22 + 22 + 22 + 25

22 + 22 + 22 + 22 + 35

22 + 22 + 22 + 22 + 50

22 + 22 + 22 + 22 + 60

22 + 22 + 22 + 22 + 71

22 + 22 + 22 + 22 + 100

22 + 22 + 22 + 25 + 25

22 + 22 + 22 + 25 + 35

22 + 22 + 22 + 25 + 50

22 + 22 + 22 + 25 + 60

22 + 22 + 22 + 25 + 71

22 + 22 + 22 + 25 + 100

22 + 22 + 22 + 35 + 35

22 + 22 + 22 + 35 + 50

22 + 22 + 22 + 35 + 60

22 + 22 + 22 + 35 + 71

22 + 22 + 22 + 35 + 100

22 + 22 + 22 + 50 + 50

22 + 22 + 22 + 50 + 60

22 + 22 + 22 + 50 + 71

22 + 22 + 22 + 60 + 60

22 + 22 + 22 + 60 + 71

22 + 22 + 25 + 25 + 25

22 + 22 + 25 + 25 + 35

22 + 22 + 25 + 25 + 50

22 + 22 + 25 + 25 + 60

Unit A

1.93 / 2.49

1.94 / 2.50

1.83 / 2.36

1.73 / 2.23

2.00 / 2.57

1.89 / 2.43

1.79 / 2.30

1.79 / 2.31

3.50 / 4.50

3.16 / 4.06

2.97 / 3.82

2.78 / 3.58

2.88 / 3.71

2.72 / 3.50

2.57 / 3.30

2.58 / 3.32

2.44 / 3.13

2.65 / 3.41

2.51 / 3.23

3.50 / 4.50

2.20 / 2.56

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.08 / 2.68

1.94 / 2.49

1.64 / 2.11

2.20 / 2.56

2.20 / 2.55

2.18 / 2.81

2.04 / 2.62

1.90 / 2.44

1.61 / 2.07

2.20 / 2.56

2.04 / 2.62

1.91 / 2.46

1.79 / 2.30

1.53 / 1.97

1.86 / 2.39

1.75 / 2.25

1.65 / 2.12

1.66 / 2.13

1.56 / 2.01

2.20 / 2.55

2.20 / 2.56

2.14 / 2.75

2.00 / 2.57

Unit B

2.71 / 3.48

2.72 / 3.50

2.57 / 3.30

2.43 / 3.12

4.00 / 5.14

3.78 / 4.86

3.57 / 4.59

3.59 / 4.62

3.50 / 4.50

3.16 / 4.06

2.97 / 3.82

2.78 / 3.58

2.88 / 3.71

2.72 / 3.50

2.57 / 3.30

2.58 / 3.32

2.44 / 3.13

3.78 / 4.86

3.59 / 4.62

3.50 / 4.50

2.20 / 2.56

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.08 / 2.68

1.94 / 2.49

1.64 / 2.11

2.20 / 2.56

2.20 / 2.55

2.18 / 2.81

2.04 / 2.62

1.90 / 2.44

1.61 / 2.07

2.20 / 2.56

2.04 / 2.62

1.91 / 2.46

1.79 / 2.30

1.53 / 1.97

1.86 / 2.39

1.75 / 2.25

1.65 / 2.12

1.66 / 2.13

1.56 / 2.01

2.20 / 2.55

2.20 / 2.56

2.14 / 2.75

2.00 / 2.57

Unit C

3.87 / 4.97

4.67 / 6.00

4.40 / 5.65

4.92 / 6.33

4.00 / 5.14

3.78 / 4.86

3.57 / 4.59

4.31 / 5.54

3.50 / 4.50

3.16 / 4.06

2.97 / 3.82

2.78 / 3.58

4.12 / 5.29

3.89 / 5.00

3.66 / 4.71

4.42 / 5.68

4.18 / 5.37

3.78 / 4.86

3.59 / 4.62

3.50 / 4.50

2.20 / 2.56

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.08 / 2.68

1.94 / 2.49

1.64 / 2.11

2.20 / 2.56

2.20 / 2.55

2.18 / 2.81

2.04 / 2.62

1.90 / 2.44

1.61 / 2.07

2.20 / 2.56

2.04 / 2.62

1.91 / 2.46

1.79 / 2.30

1.53 / 1.97

1.86 / 2.39

1.75 / 2.25

1.65 / 2.12

1.66 / 2.13

1.56 / 2.01

2.50 / 2.90

2.50 / 2.91

2.43 / 3.13

2.27 / 2.92

Unit D

5.49 / 7.06

4.67 / 6.00

5.20 / 6.69

4.92 / 6.33

4.00 / 5.14

4.54 / 5.84

5.07 / 6.52

4.31 / 5.54

3.50 / 4.50

4.52 / 5.81

5.09 / 6.55

5.65 / 7.26

4.12 / 5.29

4.67 / 6.00

5.20 / 6.69

4.42 / 5.68

4.95 / 6.36

3.78 / 4.86

4.31 / 5.54

3.50 / 4.50

2.20 / 2.56

2.20 / 2.55

2.20 / 2.56

2.20 / 2.55

2.08 / 2.68

1.94 / 2.49

1.64 / 2.11

2.50 / 2.91

2.50 / 2.90

2.48 / 3.19

2.32 / 2.98

2.16 / 2.78

1.83 / 2.36

3.50 / 4.07

3.25 / 4.17

3.04 / 3.91

2.85 / 3.66

2.44 / 3.13

4.22 / 5.42

3.98 / 5.11

3.74 / 4.81

4.52 / 5.81

4.26 / 5.48

2.50 / 2.90

2.50 / 2.91

2.43 / 3.13

2.27 / 2.92

Unit E

2.20 / 2.56

2.50 / 2.90

3.50 / 4.07

5.00 / 5.80

5.68 / 7.30

6.25 / 8.04

7.45 / 9.57

2.50 / 2.91

3.50 / 4.06

4.96 / 6.38

5.56 / 7.15

6.14 / 7.89

7.33 / 9.42

3.50 / 4.07

4.64 / 5.96

5.22 / 6.71

5.78 / 7.43

6.97 / 8.96

4.22 / 5.42

4.77 / 6.14

5.32 / 6.83

4.52 / 5.81

5.05 / 6.49

2.50 / 2.90

3.50 / 4.07

4.86 / 6.25

5.45 / 7.01

Unit F Unit G Unit H

Indoor unitcombination

Cooling / Heating Capacity (kW)

22 + 22 + 25 + 25 + 71

22 + 22 + 25 + 25 + 100

22 + 22 + 25 + 35 + 35

22 + 22 + 25 + 35 + 50

22 + 22 + 25 + 35 + 60

22 + 22 + 25 + 35 + 71

22 + 22 + 25 + 50 + 50

22 + 22 + 25 + 50 + 60

22 + 22 + 25 + 50 + 71

22 + 22 + 25 + 60 + 60

22 + 22 + 25 + 60 + 71

22 + 22 + 35 + 35 + 35

22 + 22 + 35 + 35 + 50

22 + 22 + 35 + 35 + 60

22 + 22 + 35 + 35 + 71

22 + 22 + 35 + 50 + 50

22 + 22 + 35 + 50 + 60

22 + 22 + 35 + 50 + 71

22 + 22 + 35 + 60 + 60

22 + 22 + 50 + 50 + 50

22 + 25 + 25 + 25 + 25

22 + 25 + 25 + 25 + 35

22 + 25 + 25 + 25 + 50

22 + 25 + 25 + 25 + 60

22 + 25 + 25 + 25 + 71

22 + 25 + 25 + 25 + 100

22 + 25 + 25 + 35 + 35

22 + 25 + 25 + 35 + 50

22 + 25 + 25 + 35 + 60

22 + 25 + 25 + 35 + 71

22 + 25 + 25 + 50 + 50

22 + 25 + 25 + 50 + 60

22 + 25 + 25 + 50 + 71

22 + 25 + 25 + 60 + 60

22 + 25 + 35 + 35 + 35

22 + 25 + 35 + 35 + 50

22 + 25 + 35 + 35 + 60

22 + 25 + 35 + 35 + 71

22 + 25 + 35 + 50 + 50

22 + 25 + 35 + 50 + 60

22 + 25 + 35 + 60 + 60

22 + 25 + 50 + 50 + 50

22 + 35 + 35 + 35 + 35

22 + 35 + 35 + 35 + 50

22 + 35 + 35 + 35 + 60

22 + 35 + 35 + 35 + 71

22 + 35 + 35 + 50 + 50

22 + 35 + 35 + 50 + 60

25 + 25 + 25 + 25 + 25

Unit A

1.87 / 2.40

1.59 / 2.04

2.20 / 2.55

2.00 / 2.57

1.88 / 2.41

1.76 / 2.26

1.82 / 2.34

1.72 / 2.21

1.62 / 2.08

1.63 / 2.10

1.54 / 1.98

2.07 / 2.66

1.88 / 2.41

1.77 / 2.28

1.66 / 2.14

1.72 / 2.21

1.63 / 2.10

1.54 / 1.98

1.55 / 1.99

1.59 / 2.04

2.20 / 2.56

2.20 / 2.55

2.10 / 2.69

1.96 / 2.52

1.83 / 2.36

1.56 / 2.01

2.17 / 2.79

1.96 / 2.52

1.84 / 2.37

1.73 / 2.22

1.79 / 2.30

1.69 / 2.18

1.60 / 2.05

1.60 / 2.06

2.03 / 2.61

1.84 / 2.37

1.74 / 2.24

1.64 / 2.11

1.69 / 2.18

1.60 / 2.06

1.52 / 1.96

1.56 / 2.01

1.90 / 2.44

1.74 / 2.24

1.65 / 2.12

1.56 / 2.00

1.60 / 2.06

1.52 / 1.96

2.50 / 2.90

Unit B

1.87 / 2.40

1.59 / 2.04

2.20 / 2.55

2.00 / 2.57

1.88 / 2.41

1.76 / 2.26

1.82 / 2.34

1.72 / 2.21

1.62 / 2.08

1.63 / 2.10

1.54 / 1.98

2.07 / 2.66

1.88 / 2.41

1.77 / 2.28

1.66 / 2.14

1.72 / 2.21

1.63 / 2.10

1.54 / 1.98

1.55 / 1.99

1.59 / 2.04

2.50 / 2.91

2.50 / 2.90

2.38 / 3.06

2.23 / 2.87

2.08 / 2.68

1.78 / 2.28

2.46 / 3.17

2.23 / 2.87

2.10 / 2.69

1.97 / 2.53

2.03 / 2.62

1.92 / 2.47

1.81 / 2.33

1.82 / 2.34

2.30 / 2.96

2.10 / 2.69

1.98 / 2.54

1.86 / 2.39

1.92 / 2.47

1.82 / 2.34

1.73 / 2.23

1.78 / 2.28

3.02 / 3.89

2.77 / 3.56

2.62 / 3.37

2.47 / 3.18

2.55 / 3.28

2.43 / 3.12

2.50 / 2.90

Unit C

2.12 / 2.73

1.80 / 2.32

2.50 / 2.90

2.27 / 2.92

2.13 / 2.74

2.00 / 2.57

2.07 / 2.66

1.96 / 2.51

1.84 / 2.37

1.85 / 2.38

1.75 / 2.25

3.29 / 4.23

2.99 / 3.84

2.82 / 3.62

2.65 / 3.41

2.74 / 3.52

2.59 / 3.33

2.45 / 3.15

2.46 / 3.17

3.61 / 4.64

2.50 / 2.91

2.50 / 2.90

2.38 / 3.06

2.23 / 2.87

2.08 / 2.68

1.78 / 2.28

2.46 / 3.17

2.23 / 2.87

2.10 / 2.69

1.97 / 2.53

2.03 / 2.62

1.92 / 2.47

1.81 / 2.33

1.82 / 2.34

3.22 / 4.14

2.93 / 3.77

2.77 / 3.56

2.61 / 3.35

2.69 / 3.46

2.55 / 3.28

2.43 / 3.12

3.55 / 4.57

3.02 / 3.89

2.77 / 3.56

2.62 / 3.37

2.47 / 3.18

2.55 / 3.28

2.43 / 3.12

2.50 / 2.90

Unit D

2.12 / 2.73

1.80 / 2.32

3.50 / 4.05

3.18 / 4.09

2.99 / 3.84

2.80 / 3.60

4.14 / 5.33

3.91 / 5.03

3.68 / 4.74

4.44 / 5.71

4.20 / 5.40

3.29 / 4.23

2.99 / 3.84

2.82 / 3.62

2.65 / 3.41

3.91 / 5.03

3.70 / 4.76

3.50 / 4.50

4.22 / 5.43

3.61 / 4.64

2.50 / 2.91

2.50 / 2.90

2.38 / 3.06

2.23 / 2.87

2.08 / 2.68

1.78 / 2.28

3.45 / 4.44

3.12 / 4.01

2.93 / 3.77

2.75 / 3.54

4.07 / 5.23

3.85 / 4.95

3.63 / 4.66

4.38 / 5.63

3.22 / 4.14

2.93 / 3.77

2.77 / 3.56

2.61 / 3.35

3.85 / 4.95

3.65 / 4.69

4.16 / 5.35

3.55 / 4.57

3.02 / 3.89

2.77 / 3.56

2.62 / 3.37

2.47 / 3.18

3.65 / 4.69

3.47 / 4.46

2.50 / 2.90

Unit E

6.02 / 7.75

7.22 / 9.28

3.50 / 4.05

4.55 / 5.84

5.12 / 6.59

5.68 / 7.30

4.14 / 5.33

4.69 / 6.03

5.23 / 6.73

4.44 / 5.71

4.97 / 6.39

3.29 / 4.23

4.27 / 5.49

4.83 / 6.21

5.37 / 6.91

3.91 / 5.03

4.44 / 5.71

4.97 / 6.39

4.22 / 5.43

3.61 / 4.64

2.50 / 2.91

3.50 / 4.06

4.76 / 6.12

5.35 / 6.88

5.92 / 7.61

7.11 / 9.14

3.45 / 4.44

4.46 / 5.73

5.03 / 6.47

5.58 / 7.18

4.07 / 5.23

4.62 / 5.93

5.15 / 6.62

4.38 / 5.63

3.22 / 4.14

4.19 / 5.39

4.75 / 6.10

5.29 / 6.80

3.85 / 4.95

4.38 / 5.63

4.16 / 5.35

3.55 / 4.57

3.02 / 3.89

3.95 / 5.08

4.49 / 5.78

5.02 / 6.45

3.65 / 4.69

4.16 / 5.35

2.50 / 2.90

Unit F Unit G Unit H

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 55Page 54

Page 32: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

22 + 22 + 22 + 25 + 25 + 50

22 + 22 + 22 + 25 + 25 + 60

22 + 22 + 22 + 25 + 25 + 71

22 + 22 + 22 + 25 + 35 + 35

22 + 22 + 22 + 25 + 35 + 50

22 + 22 + 22 + 25 + 35 + 60

22 + 22 + 22 + 25 + 35 + 71

22 + 22 + 22 + 25 + 50 + 50

22 + 22 + 22 + 25 + 50 + 60

22 + 22 + 22 + 35 + 35 + 35

22 + 22 + 22 + 35 + 35 + 50

22 + 22 + 22 + 35 + 35 + 60

22 + 22 + 22 + 35 + 50 + 50

22 + 22 + 25 + 25 + 25 + 25

22 + 22 + 25 + 25 + 25 + 35

22 + 22 + 25 + 25 + 25 + 50

22 + 22 + 25 + 25 + 25 + 60

22 + 22 + 25 + 25 + 25 + 71

22 + 22 + 25 + 25 + 35 + 35

22 + 22 + 25 + 25 + 35 + 50

22 + 22 + 25 + 25 + 35 + 60

22 + 22 + 25 + 25 + 35 + 71

22 + 22 + 25 + 25 + 50 + 50

22 + 22 + 25 + 35 + 35 + 35

22 + 22 + 25 + 35 + 35 + 50

22 + 22 + 25 + 35 + 35 + 60

22 + 22 + 35 + 35 + 35 + 35

22 + 22 + 35 + 35 + 35 + 50

22 + 25 + 25 + 25 + 25 + 25

22 + 25 + 25 + 25 + 25 + 35

22 + 25 + 25 + 25 + 25 + 50

22 + 25 + 25 + 25 + 25 + 60

22 + 25 + 25 + 25 + 25 + 71

22 + 25 + 25 + 25 + 35 + 35

22 + 25 + 25 + 25 + 35 + 50

22 + 25 + 25 + 25 + 35 + 60

22 + 25 + 25 + 25 + 50 + 50

22 + 25 + 25 + 35 + 35 + 35

22 + 25 + 25 + 35 + 35 + 50

22 + 25 + 25 + 35 + 35 + 60

22 + 25 + 35 + 35 + 35 + 35

22 + 25 + 35 + 35 + 35 + 50

22 + 35 + 35 + 35 + 35 + 35

25 + 25 + 25 + 25 + 25 + 25

25 + 25 + 25 + 25 + 25 + 35

25 + 25 + 25 + 25 + 25 + 50

25 + 25 + 25 + 25 + 25 + 60

25 + 25 + 25 + 25 + 25 + 71

25 + 25 + 25 + 25 + 35 + 35

25 + 25 + 25 + 25 + 35 + 50

Unit A

1.86 / 2.39

1.75 / 2.25

1.65 / 2.12

1.91 / 2.46

1.75 / 2.25

1.66 / 2.13

1.56 / 2.01

1.61 / 2.07

1.53 / 1.97

1.80 / 2.32

1.66 / 2.13

1.57 / 2.02

1.53 / 1.97

2.14 / 2.75

2.00 / 2.57

1.82 / 2.34

1.72 / 2.21

1.62 / 2.08

1.88 / 2.41

1.72 / 2.21

1.63 / 2.10

1.54 / 1.98

1.59 / 2.04

1.77 / 2.28

1.63 / 2.10

1.55 / 1.99

1.67 / 2.15

1.55 / 1.99

2.10 / 2.69

1.96 / 2.52

1.79 / 2.30

1.69 / 2.18

1.60 / 2.05

1.84 / 2.37

1.69 / 2.18

1.60 / 2.06

1.56 / 2.01

1.74 / 2.24

1.60 / 2.06

1.52 / 1.96

1.65 / 2.12

1.52 / 1.96

1.56 / 2.01

2.33 / 3.00

2.19 / 2.81

2.00 / 2.57

1.89 / 2.43

1.79 / 2.30

2.06 / 2.65

1.89 / 2.43

Unit B

1.86 / 2.39

1.75 / 2.25

1.65 / 2.12

1.91 / 2.46

1.75 / 2.25

1.66 / 2.13

1.56 / 2.01

1.61 / 2.07

1.53 / 1.97

1.80 / 2.32

1.66 / 2.13

1.57 / 2.02

1.53 / 1.97

2.14 / 2.75

2.00 / 2.57

1.82 / 2.34

1.72 / 2.21

1.62 / 2.08

1.88 / 2.41

1.72 / 2.21

1.63 / 2.10

1.54 / 1.98

1.59 / 2.04

1.77 / 2.28

1.63 / 2.10

1.55 / 1.99

1.67 / 2.15

1.55 / 1.99

2.38 / 3.06

2.23 / 2.87

2.03 / 2.62

1.92 / 2.47

1.81 / 2.33

2.10 / 2.69

1.92 / 2.47

1.82 / 2.34

1.78 / 2.28

1.98 / 2.54

1.82 / 2.34

1.73 / 2.23

1.87 / 2.41

1.73 / 2.23

2.49 / 3.20

2.33 / 3.00

2.19 / 2.81

2.00 / 2.57

1.89 / 2.43

1.79 / 2.30

2.06 / 2.65

1.89 / 2.43

Unit C

1.86 / 2.39

1.75 / 2.25

1.65 / 2.12

1.91 / 2.46

1.75 / 2.25

1.66 / 2.13

1.56 / 2.01

1.61 / 2.07

1.53 / 1.97

1.80 / 2.32

1.66 / 2.13

1.57 / 2.02

1.53 / 1.97

2.43 / 3.13

2.27 / 2.92

2.07 / 2.66

1.96 / 2.51

1.84 / 2.37

2.13 / 2.74

1.96 / 2.51

1.85 / 2.38

1.75 / 2.25

1.80 / 2.32

2.01 / 2.59

1.85 / 2.38

1.76 / 2.26

2.66 / 3.42

2.46 / 3.17

2.38 / 3.06

2.23 / 2.87

2.03 / 2.62

1.92 / 2.47

1.81 / 2.33

2.10 / 2.69

1.92 / 2.47

1.82 / 2.34

1.78 / 2.28

1.98 / 2.54

1.82 / 2.34

1.73 / 2.23

2.62 / 3.37

2.43 / 3.12

2.49 / 3.20

2.33 / 3.00

2.19 / 2.81

2.00 / 2.57

1.89 / 2.43

1.79 / 2.30

2.06 / 2.65

1.89 / 2.43

Unit D

2.11 / 2.71

1.99 / 2.56

1.87 / 2.41

2.17 / 2.80

1.99 / 2.56

1.88 / 2.42

1.78 / 2.28

1.83 / 2.36

1.74 / 2.24

2.87 / 3.68

2.63 / 3.39

2.50 / 3.21

2.44 / 3.13

2.43 / 3.13

2.27 / 2.92

2.07 / 2.66

1.96 / 2.51

1.84 / 2.37

2.13 / 2.74

1.96 / 2.51

1.85 / 2.38

1.75 / 2.25

1.80 / 2.32

2.82 / 3.62

2.59 / 3.33

2.46 / 3.17

2.66 / 3.42

2.46 / 3.17

2.38 / 3.06

2.23 / 2.87

2.03 / 2.62

1.92 / 2.47

1.81 / 2.33

2.10 / 2.69

1.92 / 2.47

1.82 / 2.34

1.78 / 2.28

2.77 / 3.56

2.55 / 3.28

2.43 / 3.12

2.62 / 3.37

2.43 / 3.12

2.49 / 3.20

2.33 / 3.00

2.19 / 2.81

2.00 / 2.57

1.89 / 2.43

1.79 / 2.30

2.06 / 2.65

1.89 / 2.43

Unit E

2.11 / 2.71

1.99 / 2.56

1.87 / 2.41

3.04 / 3.91

2.78 / 3.58

2.63 / 3.39

2.49 / 3.20

3.66 / 4.71

3.48 / 4.48

2.87 / 3.68

2.63 / 3.39

2.50 / 3.21

3.48 / 4.48

2.43 / 3.13

2.27 / 2.92

2.07 / 2.66

1.96 / 2.51

1.84 / 2.37

2.99 / 3.84

2.74 / 3.52

2.59 / 3.33

2.45 / 3.15

3.61 / 4.64

2.82 / 3.62

2.59 / 3.33

2.46 / 3.17

2.66 / 3.42

2.46 / 3.17

2.38 / 3.06

2.23 / 2.87

2.03 / 2.62

1.92 / 2.47

1.81 / 2.33

2.93 / 3.77

2.69 / 3.46

2.55 / 3.28

3.55 / 4.57

2.77 / 3.56

2.55 / 3.28

2.43 / 3.12

2.62 / 3.37

2.43 / 3.12

2.49 / 3.20

2.33 / 3.00

2.19 / 2.81

2.00 / 2.57

1.89 / 2.43

1.79 / 2.30

2.88 / 3.71

2.65 / 3.41

Unit F

4.22 / 5.42

4.77 / 6.14

5.32 / 6.83

3.04 / 3.91

3.98 / 5.11

4.52 / 5.81

5.05 / 6.49

3.66 / 4.71

4.18 / 5.37

2.87 / 3.68

3.76 / 4.84

4.29 / 5.51

3.48 / 4.48

2.43 / 3.13

3.18 / 4.09

4.14 / 5.33

4.69 / 6.03

5.23 / 6.73

2.99 / 3.84

3.91 / 5.03

4.44 / 5.71

4.97 / 6.39

3.61 / 4.64

2.82 / 3.62

3.70 / 4.76

4.22 / 5.43

2.66 / 3.42

3.52 / 4.52

2.38 / 3.06

3.12 / 4.01

4.07 / 5.23

4.62 / 5.93

5.15 / 6.62

2.93 / 3.77

3.85 / 4.95

4.38 / 5.63

3.55 / 4.57

2.77 / 3.56

3.65 / 4.69

4.16 / 5.35

2.62 / 3.37

3.47 / 4.46

2.49 / 3.20

2.33 / 3.00

3.06 / 3.94

4.00 / 5.14

4.54 / 5.84

5.07 / 6.52

2.88 / 3.71

3.78 / 4.86

Unit G Unit H

Indoor unitcombination

Cooling / Heating Capacity (kW)

25 + 25 + 25 + 25 + 35

25 + 25 + 25 + 25 + 50

25 + 25 + 25 + 25 + 60

25 + 25 + 25 + 25 + 71

25 + 25 + 25 + 25 + 100

25 + 25 + 25 + 35 + 35

25 + 25 + 25 + 35 + 50

25 + 25 + 25 + 35 + 60

25 + 25 + 25 + 35 + 71

25 + 25 + 25 + 50 + 50

25 + 25 + 25 + 50 + 60

25 + 25 + 25 + 50 + 71

25 + 25 + 25 + 60 + 60

25 + 25 + 35 + 35 + 35

25 + 25 + 35 + 35 + 50

25 + 25 + 35 + 35 + 60

25 + 25 + 35 + 35 + 71

25 + 25 + 35 + 50 + 50

25 + 25 + 35 + 50 + 60

25 + 25 + 50 + 50 + 50

25 + 35 + 35 + 35 + 35

25 + 35 + 35 + 35 + 50

25 + 35 + 35 + 35 + 60

25 + 35 + 35 + 35 + 71

25 + 35 + 35 + 50 + 50

35 + 35 + 35 + 35 + 35

35 + 35 + 35 + 35 + 50

35 + 35 + 35 + 35 + 60

6 ROOMS22 + 22 + 22 + 22 + 22 + 22

22 + 22 + 22 + 22 + 22 + 25

22 + 22 + 22 + 22 + 22 + 35

22 + 22 + 22 + 22 + 22 + 50

22 + 22 + 22 + 22 + 22 + 60

22 + 22 + 22 + 22 + 22 + 71

22 + 22 + 22 + 22 + 25 + 25

22 + 22 + 22 + 22 + 25 + 35

22 + 22 + 22 + 22 + 25 + 50

22 + 22 + 22 + 22 + 25 + 60

22 + 22 + 22 + 22 + 25 + 71

22 + 22 + 22 + 22 + 35 + 35

22 + 22 + 22 + 22 + 35 + 50

22 + 22 + 22 + 22 + 35 + 60

22 + 22 + 22 + 22 + 35 + 71

22 + 22 + 22 + 22 + 50 + 50

22 + 22 + 22 + 22 + 50 + 60

22 + 22 + 22 + 25 + 25 + 25

22 + 22 + 22 + 25 + 25 + 35

Unit A

2.50 / 2.91

2.33 / 3.00

2.19 / 2.81

2.05 / 2.63

1.75 / 2.25

2.41 / 3.10

2.19 / 2.81

2.06 / 2.65

1.93 / 2.49

2.00 / 2.57

1.89 / 2.43

1.79 / 2.30

1.79 / 2.31

2.26 / 2.90

2.06 / 2.65

1.94 / 2.50

1.83 / 2.36

1.89 / 2.43

1.79 / 2.31

1.75 / 2.25

2.12 / 2.73

1.94 / 2.50

1.84 / 2.37

1.74 / 2.24

1.79 / 2.31

2.80 / 3.60

2.58 / 3.32

2.45 / 3.15

2.20 / 2.55

2.20 / 2.56

2.12 / 2.73

1.93 / 2.48

1.81 / 2.33

1.70 / 2.19

2.20 / 2.55

2.08 / 2.68

1.89 / 2.43

1.78 / 2.29

1.67 / 2.15

1.95 / 2.51

1.78 / 2.29

1.68 / 2.16

1.59 / 2.04

1.64 / 2.11

1.56 / 2.00

2.18 / 2.81

2.04 / 2.62

Unit B

2.50 / 2.91

2.33 / 3.00

2.19 / 2.81

2.05 / 2.63

1.75 / 2.25

2.41 / 3.10

2.19 / 2.81

2.06 / 2.65

1.93 / 2.49

2.00 / 2.57

1.89 / 2.43

1.79 / 2.30

1.79 / 2.31

2.26 / 2.90

2.06 / 2.65

1.94 / 2.50

1.83 / 2.36

1.89 / 2.43

1.79 / 2.31

1.75 / 2.25

2.97 / 3.82

2.72 / 3.50

2.58 / 3.32

2.44 / 3.13

2.51 / 3.23

2.80 / 3.60

2.58 / 3.32

2.45 / 3.15

2.20 / 2.55

2.20 / 2.56

2.12 / 2.73

1.93 / 2.48

1.81 / 2.33

1.70 / 2.19

2.20 / 2.55

2.08 / 2.68

1.89 / 2.43

1.78 / 2.29

1.67 / 2.15

1.95 / 2.51

1.78 / 2.29

1.68 / 2.16

1.59 / 2.04

1.64 / 2.11

1.56 / 2.00

2.18 / 2.81

2.04 / 2.62

Unit C

2.50 / 2.91

2.33 / 3.00

2.19 / 2.81

2.05 / 2.63

1.75 / 2.25

2.41 / 3.10

2.19 / 2.81

2.06 / 2.65

1.93 / 2.49

2.00 / 2.57

1.89 / 2.43

1.79 / 2.30

1.79 / 2.31

3.16 / 4.06

2.88 / 3.71

2.72 / 3.50

2.57 / 3.30

2.65 / 3.41

2.51 / 3.23

3.50 / 4.50

2.97 / 3.82

2.72 / 3.50

2.58 / 3.32

2.44 / 3.13

2.51 / 3.23

2.80 / 3.60

2.58 / 3.32

2.45 / 3.15

2.20 / 2.55

2.20 / 2.56

2.12 / 2.73

1.93 / 2.48

1.81 / 2.33

1.70 / 2.19

2.20 / 2.55

2.08 / 2.68

1.89 / 2.43

1.78 / 2.29

1.67 / 2.15

1.95 / 2.51

1.78 / 2.29

1.68 / 2.16

1.59 / 2.04

1.64 / 2.11

1.56 / 2.00

2.18 / 2.81

2.04 / 2.62

Unit D

2.50 / 2.91

2.33 / 3.00

2.19 / 2.81

2.05 / 2.63

1.75 / 2.25

3.38 / 4.34

3.06 / 3.94

2.88 / 3.71

2.71 / 3.48

4.00 / 5.14

3.78 / 4.86

3.57 / 4.59

4.31 / 5.54

3.16 / 4.06

2.88 / 3.71

2.72 / 3.50

2.57 / 3.30

3.78 / 4.86

3.59 / 4.62

3.50 / 4.50

2.97 / 3.82

2.72 / 3.50

2.58 / 3.32

2.44 / 3.13

3.59 / 4.62

2.80 / 3.60

2.58 / 3.32

2.45 / 3.15

2.20 / 2.55

2.20 / 2.56

2.12 / 2.73

1.93 / 2.48

1.81 / 2.33

1.70 / 2.19

2.20 / 2.55

2.08 / 2.68

1.89 / 2.43

1.78 / 2.29

1.67 / 2.15

1.95 / 2.51

1.78 / 2.29

1.68 / 2.16

1.59 / 2.04

1.64 / 2.11

1.56 / 2.00

2.48 / 3.19

2.32 / 2.98

Unit E

3.50 / 4.07

4.67 / 6.00

5.25 / 6.75

5.81 / 7.47

7.00 / 9.00

3.38 / 4.34

4.38 / 5.63

4.94 / 6.35

5.49 / 7.06

4.00 / 5.14

4.54 / 5.84

5.07 / 6.52

4.31 / 5.54

3.16 / 4.06

4.12 / 5.29

4.67 / 6.00

5.20 / 6.69

3.78 / 4.86

4.31 / 5.54

3.50 / 4.50

2.97 / 3.82

3.89 / 5.00

4.42 / 5.68

4.95 / 6.36

3.59 / 4.62

2.80 / 3.60

3.68 / 4.74

4.20 / 5.40

2.20 / 2.55

2.20 / 2.56

2.12 / 2.73

1.93 / 2.48

1.81 / 2.33

1.70 / 2.19

2.50 / 2.90

2.36 / 3.04

2.15 / 2.76

2.02 / 2.60

1.90 / 2.45

3.10 / 3.99

2.83 / 3.64

2.68 / 3.44

2.53 / 3.25

3.72 / 4.79

3.54 / 4.55

2.48 / 3.19

2.32 / 2.98

Unit F

2.20 / 2.55

2.50 / 2.91

3.38 / 4.34

4.38 / 5.63

4.94 / 6.35

5.49 / 7.06

2.50 / 2.90

3.31 / 4.26

4.29 / 5.52

4.86 / 6.24

5.40 / 6.95

3.10 / 3.99

4.05 / 5.20

4.59 / 5.90

5.12 / 6.59

3.72 / 4.79

4.24 / 5.45

2.48 / 3.19

3.25 / 4.17

Unit G Unit H

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 57Page 56

Page 33: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

8 ROOMS

22 + 22 + 22 + 22 + 22 + 22 + 22 + 22

22 + 22 + 22 + 22 + 22 + 22 + 22 + 25

22 + 22 + 22 + 22 + 22 + 22 + 22 + 35

22 + 22 + 22 + 22 + 22 + 22 + 25 + 25

22 + 22 + 22 + 22 + 22 + 22 + 25 + 35

22 + 22 + 22 + 22 + 22 + 22 + 35 + 35

22 + 22 + 22 + 22 + 22 + 25 + 25 + 25

22 + 22 + 22 + 22 + 22 + 25 + 25 + 35

22 + 22 + 22 + 22 + 25 + 25 + 25 + 25

22 + 22 + 22 + 22 + 25 + 25 + 25 + 35

22 + 22 + 22 + 25 + 25 + 25 + 25 + 25

22 + 22 + 22 + 25 + 25 + 25 + 25 + 35

22 + 22 + 25 + 25 + 25 + 25 + 25 + 25

22 + 25 + 25 + 25 + 25 + 25 + 25 + 25

25 + 25 + 25 + 25 + 25 + 25 + 25 + 25

Unit A

1.75 / 2.25

1.72 / 2.21

1.63 / 2.10

1.69 / 2.18

1.60 / 2.06

1.52 / 1.96

1.66 / 2.14

1.58 / 2.03

1.64 / 2.11

1.56 / 2.00

1.61 / 2.07

1.53 / 1.97

1.59 / 2.04

1.56 / 2.01

1.75 / 2.25

Unit B

1.75 / 2.25

1.72 / 2.21

1.63 / 2.10

1.69 / 2.18

1.60 / 2.06

1.52 / 1.96

1.66 / 2.14

1.58 / 2.03

1.64 / 2.11

1.56 / 2.00

1.61 / 2.07

1.53 / 1.97

1.59 / 2.04

1.78 / 2.28

1.75 / 2.25

Unit C

1.75 / 2.25

1.72 / 2.21

1.63 / 2.10

1.69 / 2.18

1.60 / 2.06

1.52 / 1.96

1.66 / 2.14

1.58 / 2.03

1.64 / 2.11

1.56 / 2.00

1.61 / 2.07

1.53 / 1.97

1.80 / 2.32

1.78 / 2.28

1.75 / 2.25

Unit D

1.75 / 2.25

1.72 / 2.21

1.63 / 2.10

1.69 / 2.18

1.60 / 2.06

1.52 / 1.96

1.66 / 2.14

1.58 / 2.03

1.64 / 2.11

1.56 / 2.00

1.83 / 2.36

1.74 / 2.24

1.80 / 2.32

1.78 / 2.28

1.75 / 2.25

Unit E

1.75 / 2.25

1.72 / 2.21

1.63 / 2.10

1.69 / 2.18

1.60 / 2.06

1.52 / 1.96

1.66 / 2.14

1.58 / 2.03

1.86 / 2.39

1.77 / 2.27

1.83 / 2.36

1.74 / 2.24

1.80 / 2.32

1.78 / 2.28

1.75 / 2.25

Unit F

1.75 / 2.25

1.72 / 2.21

1.63 / 2.10

1.69 / 2.18

1.60 / 2.06

1.52 / 1.96

1.89 / 2.43

1.79 / 2.31

1.86 / 2.39

1.77 / 2.27

1.83 / 2.36

1.74 / 2.24

1.80 / 2.32

1.78 / 2.28

1.75 / 2.25

Unit G

1.75 / 2.25

1.72 / 2.21

1.63 / 2.10

1.92 / 2.47

1.82 / 2.34

2.43 / 3.12

1.89 / 2.43

1.79 / 2.31

1.86 / 2.39

1.77 / 2.27

1.83 / 2.36

1.74 / 2.24

1.80 / 2.32

1.78 / 2.28

1.75 / 2.25

Unit H

1.75 / 2.25

1.96 / 2.51

2.59 / 3.33

1.92 / 2.47

2.55 / 3.28

2.43 / 3.12

1.89 / 2.43

2.51 / 3.23

1.86 / 2.39

2.47 / 3.18

1.83 / 2.36

2.44 / 3.13

1.80 / 2.32

1.78 / 2.28

1.75 / 2.25

Indoor unitcombination

Cooling / Heating Capacity (kW)

25 + 25 + 25 + 25 + 35 + 60

25 + 25 + 25 + 25 + 50 + 50

25 + 25 + 25 + 35 + 35 + 35

25 + 25 + 25 + 35 + 35 + 50

25 + 25 + 35 + 35 + 35 + 35

25 + 35 + 35 + 35 + 35 + 35

7 ROOMS

22 + 22 + 22 + 22 + 22 + 22 + 22

22 + 22 + 22 + 22 + 22 + 22 + 25

22 + 22 + 22 + 22 + 22 + 22 + 35

22 + 22 + 22 + 22 + 22 + 22 + 50

22 + 22 + 22 + 22 + 22 + 22 + 60

22 + 22 + 22 + 22 + 22 + 25 + 25

22 + 22 + 22 + 22 + 22 + 25 + 35

22 + 22 + 22 + 22 + 22 + 25 + 50

22 + 22 + 22 + 22 + 22 + 25 + 60

22 + 22 + 22 + 22 + 22 + 35 + 35

22 + 22 + 22 + 22 + 22 + 35 + 50

22 + 22 + 22 + 22 + 25 + 25 + 25

22 + 22 + 22 + 22 + 25 + 25 + 35

22 + 22 + 22 + 22 + 25 + 25 + 50

22 + 22 + 22 + 22 + 25 + 25 + 60

22 + 22 + 22 + 22 + 25 + 35 + 35

22 + 22 + 22 + 22 + 25 + 35 + 50

22 + 22 + 22 + 22 + 35 + 35 + 35

22 + 22 + 22 + 25 + 25 + 25 + 25

22 + 22 + 22 + 25 + 25 + 25 + 35

22 + 22 + 22 + 25 + 25 + 25 + 50

22 + 22 + 22 + 25 + 25 + 25 + 60

22 + 22 + 22 + 25 + 25 + 35 + 35

22 + 22 + 22 + 25 + 25 + 35 + 50

22 + 22 + 22 + 25 + 35 + 35 + 35

22 + 22 + 25 + 25 + 25 + 25 + 25

22 + 22 + 25 + 25 + 25 + 25 + 35

22 + 22 + 25 + 25 + 25 + 25 + 50

22 + 22 + 25 + 25 + 25 + 35 + 35

22 + 22 + 25 + 25 + 35 + 35 + 35

22 + 25 + 25 + 25 + 25 + 25 + 25

22 + 25 + 25 + 25 + 25 + 25 + 35

22 + 25 + 25 + 25 + 25 + 25 + 50

22 + 25 + 25 + 25 + 25 + 35 + 35

22 + 25 + 25 + 25 + 35 + 35 + 35

25 + 25 + 25 + 25 + 25 + 25 + 25

25 + 25 + 25 + 25 + 25 + 25 + 35

25 + 25 + 25 + 25 + 25 + 25 + 50

25 + 25 + 25 + 25 + 25 + 35 + 35

Unit A

1.79 / 2.31

1.75 / 2.25

1.94 / 2.50

1.79 / 2.31

1.84 / 2.37

1.75 / 2.25

2.00 / 2.57

1.96 / 2.52

1.84 / 2.37

1.69 / 2.18

1.60 / 2.06

1.93 / 2.48

1.81 / 2.33

1.66 / 2.14

1.58 / 2.03

1.71 / 2.20

1.58 / 2.03

1.89 / 2.43

1.78 / 2.29

1.64 / 2.11

1.56 / 2.00

1.68 / 2.16

1.56 / 2.00

1.60 / 2.05

1.86 / 2.39

1.75 / 2.25

1.61 / 2.07

1.53 / 1.97

1.66 / 2.13

1.53 / 1.97

1.57 / 2.02

1.82 / 2.34

1.72 / 2.21

1.59 / 2.04

1.63 / 2.10

1.55 / 1.99

1.79 / 2.30

1.69 / 2.18

1.56 / 2.01

1.60 / 2.06

1.52 / 1.96

2.00 / 2.57

1.89 / 2.43

1.75 / 2.25

1.79 / 2.31

Unit B

1.79 / 2.31

1.75 / 2.25

1.94 / 2.50

1.79 / 2.31

1.84 / 2.37

2.45 / 3.15

2.00 / 2.57

1.96 / 2.52

1.84 / 2.37

1.69 / 2.18

1.60 / 2.06

1.93 / 2.48

1.81 / 2.33

1.66 / 2.14

1.58 / 2.03

1.71 / 2.20

1.58 / 2.03

1.89 / 2.43

1.78 / 2.29

1.64 / 2.11

1.56 / 2.00

1.68 / 2.16

1.56 / 2.00

1.60 / 2.05

1.86 / 2.39

1.75 / 2.25

1.61 / 2.07

1.53 / 1.97

1.66 / 2.13

1.53 / 1.97

1.57 / 2.02

1.82 / 2.34

1.72 / 2.21

1.59 / 2.04

1.63 / 2.10

1.55 / 1.99

2.03 / 2.62

1.92 / 2.47

1.78 / 2.28

1.82 / 2.34

1.73 / 2.23

2.00 / 2.57

1.89 / 2.43

1.75 / 2.25

1.79 / 2.31

Unit C

1.79 / 2.31

1.75 / 2.25

1.94 / 2.50

1.79 / 2.31

2.58 / 3.32

2.45 / 3.15

2.00 / 2.57

1.96 / 2.52

1.84 / 2.37

1.69 / 2.18

1.60 / 2.06

1.93 / 2.48

1.81 / 2.33

1.66 / 2.14

1.58 / 2.03

1.71 / 2.20

1.58 / 2.03

1.89 / 2.43

1.78 / 2.29

1.64 / 2.11

1.56 / 2.00

1.68 / 2.16

1.56 / 2.00

1.60 / 2.05

1.86 / 2.39

1.75 / 2.25

1.61 / 2.07

1.53 / 1.97

1.66 / 2.13

1.53 / 1.97

1.57 / 2.02

2.07 / 2.66

1.96 / 2.51

1.80 / 2.32

1.85 / 2.38

1.76 / 2.26

2.03 / 2.62

1.92 / 2.47

1.78 / 2.28

1.82 / 2.34

1.73 / 2.23

2.00 / 2.57

1.89 / 2.43

1.75 / 2.25

1.79 / 2.31

Unit D

1.79 / 2.31

1.75 / 2.25

2.72 / 3.50

2.51 / 3.23

2.58 / 3.32

2.45 / 3.15

2.00 / 2.57

1.96 / 2.52

1.84 / 2.37

1.69 / 2.18

1.60 / 2.06

1.93 / 2.48

1.81 / 2.33

1.66 / 2.14

1.58 / 2.03

1.71 / 2.20

1.58 / 2.03

1.89 / 2.43

1.78 / 2.29

1.64 / 2.11

1.56 / 2.00

1.68 / 2.16

1.56 / 2.00

1.60 / 2.05

2.11 / 2.71

1.99 / 2.56

1.83 / 2.36

1.74 / 2.24

1.88 / 2.42

1.74 / 2.24

1.79 / 2.30

2.07 / 2.66

1.96 / 2.51

1.80 / 2.32

1.85 / 2.38

1.76 / 2.26

2.03 / 2.62

1.92 / 2.47

1.78 / 2.28

1.82 / 2.34

1.73 / 2.23

2.00 / 2.57

1.89 / 2.43

1.75 / 2.25

1.79 / 2.31

Unit E

2.51 / 3.23

3.50 / 4.50

2.72 / 3.50

2.51 / 3.23

2.58 / 3.32

2.45 / 3.15

2.00 / 2.57

1.96 / 2.52

1.84 / 2.37

1.69 / 2.18

1.60 / 2.06

1.93 / 2.48

1.81 / 2.33

1.66 / 2.14

1.58 / 2.03

1.71 / 2.20

1.58 / 2.03

2.15 / 2.76

2.02 / 2.60

1.86 / 2.39

1.77 / 2.27

1.91 / 2.46

1.77 / 2.27

2.54 / 3.26

2.11 / 2.71

1.99 / 2.56

1.83 / 2.36

1.74 / 2.24

1.88 / 2.42

1.74 / 2.24

2.50 / 3.21

2.07 / 2.66

1.96 / 2.51

1.80 / 2.32

1.85 / 2.38

2.46 / 3.17

2.03 / 2.62

1.92 / 2.47

1.78 / 2.28

1.82 / 2.34

2.43 / 3.12

2.00 / 2.57

1.89 / 2.43

1.75 / 2.25

1.79 / 2.31

Unit F

4.31 / 5.54

3.50 / 4.50

2.72 / 3.50

3.59 / 4.62

2.58 / 3.32

2.45 / 3.15

2.00 / 2.57

1.96 / 2.52

1.84 / 2.37

1.69 / 2.18

1.60 / 2.06

2.19 / 2.81

2.06 / 2.65

1.89 / 2.43

1.79 / 2.31

2.72 / 3.50

2.51 / 3.23

2.15 / 2.76

2.02 / 2.60

1.86 / 2.39

1.77 / 2.27

2.68 / 3.44

2.47 / 3.18

2.54 / 3.26

2.11 / 2.71

1.99 / 2.56

1.83 / 2.36

1.74 / 2.24

2.63 / 3.39

2.44 / 3.13

2.50 / 3.21

2.07 / 2.66

1.96 / 2.51

1.80 / 2.32

2.59 / 3.33

2.46 / 3.17

2.03 / 2.62

1.92 / 2.47

1.78 / 2.28

2.55 / 3.28

2.43 / 3.12

2.00 / 2.57

1.89 / 2.43

1.75 / 2.25

2.51 / 3.23

Unit G

2.00 / 2.57

2.23 / 2.87

2.93 / 3.77

3.85 / 4.95

4.38 / 5.63

2.19 / 2.81

2.88 / 3.71

3.78 / 4.86

4.31 / 5.54

2.72 / 3.50

3.59 / 4.62

2.15 / 2.76

2.83 / 3.64

3.72 / 4.79

4.24 / 5.45

2.68 / 3.44

3.54 / 4.55

2.54 / 3.26

2.11 / 2.71

2.78 / 3.58

3.66 / 4.71

4.18 / 5.37

2.63 / 3.39

3.48 / 4.48

2.50 / 3.21

2.07 / 2.66

2.74 / 3.52

3.61 / 4.64

2.59 / 3.33

2.46 / 3.17

2.03 / 2.62

2.69 / 3.46

3.55 / 4.57

2.55 / 3.28

2.43 / 3.12

2.00 / 2.57

2.65 / 3.41

3.50 / 4.50

2.51 / 3.23

Unit H

Indoor unitcombination

Cooling / Heating Capacity (kW)

Page 59Page 58

Page 34: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Out

door

Uni

t D

imen

sions

Side View >

417.5

40

175 500

330 50

Air in

Air out

360

840

109

81

880

452

99.5

164.

5

195

35

44

Front View >

Upper View >

Side View >Front View >

Upper View >

MUZ-GE50VA / SUZ-KA50VA2

MUZ-GE60/71VA

Dimensions

Page 61

M S

eri

es

Ran

geOutdoor Units

Side View >

MUZ-HC25/35VA(B)

MUZ-GE25/35VA / MUZ-FD25/35VABH / SUZ-KA25/35VA2

Upper View >

Front View >

Side View >

Upper View >

Front View >

Dimensions

Page 60

Page 35: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Acc

esso

ries

/ O

ptio

nal Ex

tras

Accessories / Optional ExtrasM Series

Catechin Filter MAC-3003CF - for MSZ-HC25/35VA(B) (10 pack)

Anti-Allergy Enzyme Filters MAC-408FT-E - for MSZ-GE22-50VA (10 pack)MAC-2310FT-E - for MSZ-GE60/71VA (10 pack)MAC-415FT-E - for MFZ-KA25-50VA (10 pack)

Wired Remote controller PAR-30MAA - for MSZ-GE22-71VA, MSZ-FD25/35VA & MFZ-KA25-50VA

Interfaces MAC-399IF - for connection to M-NET system

MAC-397IF - for Contact Terminal, PAR-30MAA Wired Remote Controller

Air Outlet Guides MAC-889SG - for MXZ-2C52VA, MUZ-HC, MUZ-GE & MUZ-FD

MAC-856SG - for MXZ-3C54VA, MXZ-4C71VA, MXZ-4C80VA & MXZ-5C100VA

PAC-SG59SG-E - for MXZ-8B140VA, MXZ-8B160YA

MXZ-8B Connection Pipe PAC-AK52YP-E - Y shaped pipe for MXZ-8B models enabling size 100 connection (PLA-RP)

Page 62

M S

eri

es

Ran

ge

Page 36: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Mr Sl im Packaged Split-SystemAir Conditioning

Air Conditioning Commercial Heating

Domestic Heating Photovoltaics

Page 37: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

The Mr Slim RangeCompact and Versatile, theOptions are Endless

Suitable to heat or cool a huge variety of applications, the Mr Slimrange is one of Britain’s best selling air conditioning split-systems.Combine the efficiency with the complete versatility that thisrange has to offer and the possibilities are virtually infinite.

The 2011 Mr Slim range has been updated with new features, as well as the already impressiveefficiency levels being improved. New to the range is an improved Standard Inverter offering, nowalso available as a 3-phase option. Complementing this, the Mr Slim Zubadan Inverter range ofoutdoor units guarantee heating operation down to -25ºC ambient air temperature, allowing set temperatures to be reached faster.

The Mr Slim range has reached a new level of energy efficiency with the incorporation of newtechnologies and a new body design. These innovations will result in lower running costs andemissions throughout the life of a system. The side flow configuration of the outdoor unit,maximum piping length of 120m and Replace Technology help to simplify installation and make Mr Slim units more than just physically compact and discreet. They are also amongst the quietestoperating units available, which means that apart from enjoying a comfortable, controllableenvironment, users hardly know Mr Slim is there at all.

Easy to fitwhereveryou need

An installers favourite, the excellentdesign of the Mr Slim range ensuresquick and simple installation with theminimum of disruption. With extensive pipe runs of up to 120m, this versatilerange makes it easier to select a layout to install the unit.

Page 65Page 64

Page 38: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

An HIC has been added to improve energy efficiency during cooling operation. Liquid refrigerant is rerouted, transformedinto a gas state and injected back into the system to increase overall pressure of the refrigerant being sent to thecompressor, thereby reducing the load on the compressor and raising efficiency.

Heat Interchanger Circuit (HIC) Added <RP140>

New

Increase in heat-exchanger

surface area

2 lines, 52 columns

2 lines, 64 columns

* 1 Based on the following operating conditions - Place-Office in Tokyo, Japan / Operating time-8am to 8pm,6 days/week / Operating period-Cooling: April 16 - November 8. Heating: December 14 - March 23 / Set temperature-Cooling: 27°C, Heating: 20˚C. Non-inverter model installed eight years ago is a PLH-3GKHB / PUH-3YKA. Power Inverter model is a PLA-RP71BA2 / PUHZ-RP71VHA4.

Page 67

Power Inver terThe Mr Slim Power Inverter range is now stronger than ever.The technological developments applied to this range of equipment offer the end user some of the highest energy efficiency ratings available, alongside greater application flexibility.

Page 66

Improved COP / EER RatingsCOP and EER ratings have increased across the board withthe introduction of the VHA4 and VKA/YKA models. Manysystems within our range now having energy labels of ‘A’ inboth heating and cooling.

Existing R22/R407c Pipe WorkThe issue of using existing pipe work has been resolved usingMitsubishi Electric’s unique ‘Replace Technology’, offering theopportunity to upgrade older, less efficient systems with theminimum of cost and installation disruption.

Reducing Power Consumption by 70%The Mr Slim Power Inverter can reduce power consumptionby up to 70% compared to a previously installed non-invertermodel*1, making the energy cost savings associated with thisrange truly remarkable. A high power function also deliversincreased capacity at times of high demand, allowing the roomtarget temperature to be reached as rapidly as possible from start up.

This range is available in single and 3-phase options, the latterhaving running currents that are more than half that of the singlephase option, offering a clear benefit to business premises that already have 3-phase supply installed. All models have lowstarting currents of 5 amps.

Highly Efficient Fan and GrilleThe shapes of the fan and grille of the outdoor unit have beenredesigned, realising an increase in discharge volume and amore efficient heat exchange, while maintaining the sameoperating noise level.

Outdoor Unit Fan Opening Increased <RP100-250>

The diameter of the fanopening in the outdoor unithas been increased from490 to 550mm. Dischargevolume has been increased,while maintaining the samefan rotation speed.

Grille Shape Changed <RP60-250>

The shape of the air outlet grille has been changed to reducepressure loss. This has helped improve heat exchange performance.

Inflexed Fan <RP100-250>

The adoption of a fanwith improved ventilationcharacteristics and a newlydesigned rear edge thatsuppresses wind turbulenceraises fan operation efficiency.

Highly Efficient Heat ExchangerA reduction in pipe diameter and an increase in surface areahave improved the overall efficiency of the heat exchanger.

High-DensityHeat Exchanger <RP100-250>

The pipe diameter for theRP100-140 has been changed from 9.52 to 7.94mm, the same diameter as that used for RP200-250 units, resulting in a high-density heat exchanger.

Heat-Exchange Surface Area Increased <RP100-250>

The heat exchanger size has been extended horizontally,increasing the surface area.

*1 When comparing the Power Inverter (PUHZ-RP71VHA4) with R22 (PUH3-VKA) in cooling.

Silent OperationOperation has been made near-silent (67% quieterthan corresponding R22 outdoor unit*1) as a result of improvement in the design of the fan blades andthe new grille shape. The Power Inverter is evenquieter at night when outside temperatures drop, as itcan be set to low-noise mode (cooling only) reducingoperating noise by 3dBA (50% quieter than normalday mode).

A low-noise priority function is also available byconnecting a separate commercially available timer or selector switch. When a signal is received from the timer or switch, the unit automatically runsin low-noise mode.

Page 39: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Pump down switch

Design with Environmental Consideration:

Low noise mode can be set at night time to reduce noise levels by approximately 50%.

The example here is usinga PUHZ-P100VHA3

1338mm

943mm

330mm 330mm

395mm

1050mm 950mm

PowerInverter

StandardInverter

116kg 75kg

Height reduced by 395mm

Weight reduced by 41kg

Day 50dBAOutdoor Temperature 35ºC

Night 47dBAOutdoor Temperature 25ºC

1/2 the audible sound(compared to

daytime)

3dBALess

Example:

Silent Outdoor Unit - Low Noise Mode

Page 69

Standard InverterThe Standard Inverter models provide an inverter solutionat a lower capital cost than the Power Inverter range. These outdoormodels continue to offer high efficiency as standard, with somesystems qualifying for Enhanced Capital Allowance.

Models are available in 10, 12.5 & 14kW single phase andnew for 2011, in 3-phase 10, 12.5, 14, 19 and 22kW sizes.

Page 68

Improved COP / EER Figures

COP / EER figures have been improved when compared to theprevious R407c range.

The 10kW model has a compact single fan design and weighsless when compared to its Power Inverter equivalent, makinginstallation easier.

Pump down switchPushing a switch starts / stops refrigerant recovery operation automatically. This process will then be completed by closing a valve.

New3-phase

models nowavailable

SUZ outdoor unitsare able to be connected

to selected Mr Slim indoorunits, creating a new range

of low cost inverter driven systems.

Smooth refrigerant recovery can be assured by pushing thepump down switch at unit movement / renewal.

Duty Standby Operation3 new functions are available with Mr Slim systems*1 :

*1 Not available when using SUZ outdoor units. Must be used in conjunction with a PAR-30MAA controller.

Rotation2 outdoor units (master & slave) operate alternately, switching every 1, 3, 5, 7, 14, 28 days (selectable).

Back UpWhen master outdoor unit fails, sub unit begins operation.

Join InWhen master outdoor unit fails to reach set temperature, sub unit operates in conjunction (available in cooling mode only).

Rotate

Back Up

Join In

Improved Fan Design and Weight

Page 40: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

The Zubadan Series is equipped with Mitsubishi Electric’soriginal Flash Injection Circuit, which is comprised of a bypass circuit and heat interchanger (HIC). The HICtransforms re-routed liquid refrigerant into a gas-liquidstate to lower compression load. This process ensuresexcellent heating performance even when the outdoortemperature drops very low.

In traditional units, when the outdoor temperature is low, the volume of refrigerant circulating in thecompressor decreases due to the drop in refrigerantpressure and high compression (to protect fromoverheating), thereby reducing heating capacity. The Flash Injection Circuit injects refrigerant to maintain the refrigerant circulation volume and compressor operation load, therebymaintaining heating capacity.

Heat Interchanger (HIC) Injection Compressor

Purpose: To increase the volume of refrigerant being circulated

Effect: Improves heating capacity at low outdoortemperatures and enables higher indoor-air outlettemperature adjustment and higher defrostoperation speed

HIC cross-sectional view

Refrigerant passes through LEV C(refrigerant pressure lowered)

Refrigerant doesn’t pass through LEV C

The compressor is subjected to a heavy load whencompressing liquid refrigerant, the result being loweroperation efficiency. The addition of HIC supportsrefrigerant heat exchange at two different pressure levels.The heat-exchange process transforms the injected liquidrefrigerant into a gas liquid state, thereby decreasing theload on the compressor during the compression process.

Refrigerant passes from the HIC into the compressorthrough the injection port. Having two refrigerant inletsmakes it possible to raise the volume of refrigerant beingcirculated when the outdoor temperature is low and atthe start of heating operation.

Discharge port

Normal refrigerant flow

Refrigerant flow

Suction port

Injection port

Purpose: Transform liquid refrigerant into liquid-gas state

Effect: Injection circuit increases energy efficiency

A B

ZUBADAN Defrost Control and FasterRecovery from Defrost Operation

Page 71

Zubadan InverterThe ZUBADAN Series incorporates Flash Injection Technologythat improves the already high heating capacity of the system. This newestmember of the Mr Slim range ensures comfortable heat pump-driven heating performance in colder regions.

Page 70

Improved Heating PerformanceMitsubishi Electric’s unique “Flash Injection Circuit”achieves a remarkably high heating performance.

This technology has resulted in an excellent heatingcapacity rating in outdoor temperatures as low as -15°Cand the guaranteed heating operation range of theheating mode has been extended to -25°C. Accordingly,the Zubadan inverters are perfect for warming homes in the coldest of regions.

Mitsubishi Electric’s Flash Injection Technology

The Key to High Heating Performanceat Low Outdoor Temperatures

Enhanced ComfortThe Flash Injection Circuit improves start-up and recovery from defrost operation. A newly introduceddefrost operation control also improves defrost frequency. These features enable the temperature to reach the settemperature more quickly and contribute to maintainingit at the desired setting.

■Operation data for 25 Jan. 2005 ■Operation data for 2 Dec. 2004

8:00 10:00 12:00 14:00 16:00 18:00 20:00 22:00

60°C

50°C

40°C

30°C

20°C

10°C

0°C

-10°C

20:0018:00

60°C

50°C

40°C

30°C

20°C

10°C

0°C

-10°C

-20°C

-30°C

22:00 0:00 2:00 4:00 6:00

Installationexample

LEV B

LEV C

LEVA

Heatinterchanger(HIC)

Refrigerant flow

A

B

IndoorHEX

Powerreceiver

OutdoorHEX

Injection compressor(injection port)

Flash Injection Circuit

Heat Interchanger (HIC)

Injection Compressor

A

B

Flash Injection Circuit

Field test results:Office building in Ashikawa, Hokkaido, Japan

Page 41: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Page 73

PLA-RP 4-Way Blow Cassette

Page 72

The PLA-RP-BA(2)(3) (PLFY-P-VBM-E for City Multi)4-Way Blow Cassette, offers a range of new features, as well as a new design and pure white colour.

Wide AirflowThe wide shape vane (capable of wide angle air supply) provides comfort at the corners of a room, regardless of cooling or heatingoperation. A reduction in the air speed by 20% (compared to the previous product) eliminates the uncomfortable draftsensation often experienced.

Reduced Draft Air DistributionReduced draft air distribution allows the vanes to supply airflow horizontally, thus preventing discomfort due to excessive cooling or from direct exposure of occupants to the air blow.

Independent Vane ControlIf the airflow direction needs to be changed as a result of analtered room layout or due to the mode selected (i.e. cooling orheating), the air direction of each vane can be set independentlyusing the PAR-30MAA wired remote controller.

� Previous product � New product

Reduced Draft AirDistribution

PAR-30MAA

Down blow

Horizontal blow

Adjustable Fixed

Automatic Airflow Adjustment ModeThe automatic airflow adjustment mode is provided in additionto the 4 normal airflow stages and allows automatic adjustmentof the airflow in accordance with the difference between the settemperature and the room temperature.

For example: The automatic airflow adjustment mode allowsquick cooling of a room using high mode, then when the roomtemperature has stabilised, the low mode will be applied tomaximise comfort.

HighLow Automatic airflowadjustmentMedium 2Medium 1

Grille with Automatic FilterLowering Function (Optional)This grille can be operated by both the wired remote controllerand the exclusive infra-red remote controller. It can be loweredin 8 steps down to 4m in accordance with the ceiling height,enabling you to easily clean the air filter. Regular cleaning of thefilter is an important factor in saving energy.

PAR-30MAA Wired Remote Controller

Elevation Grille Remote Controller(comes with the grille)

Automaticlowering

to

4m

Page 42: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

360°The "I-See Sensor" rotates to measure the floor temperature

The (optional corner panel) Provides EvenTemperature Distribution and Reduces Energy Consumption

The “I-See Sensor” uses temperature sensing technologydeveloped by Mitsubishi Electric. In order to create acomfortable environment in shops and offices, it is essentialto control the temperature near the floor where occupantsand visitors gather. The “I-See Sensor”measures the infra-redrays generated from the surrounding wall and floor surfacesand converts these into temperature values.

In addition, floor temperatures are also measured at distantspots, allowing optimum airflow to reach these areas.

� “I-See Sensor” operation: The “I-See Sensor”rotates slowly in intervals of 5 seconds, correctlymeasuring the temperature of the entire floor space.

5 seconds 5 seconds 5 seconds 5 seconds

In the past... only the inlet temperature near theceiling was measured, tending to overlook the uneventemperature distribution near the floor.

Conventional air conditioning in shops and offices only measuredthe temperature near to the ceiling, therefore the uneventemperature distribution between the ceiling and the floorremained unchecked.

As a result, the set temperature tended to be higher in orderto obtain comfort at floor level.

Inlet temperature sensor

Area measured by cassette model without "I-See Sensor"

37ºC

25ºC

13ºC

Without “I-See Sensor”.Set temperature is23ºC (in Heating)

e.g. To achieve a sensible temperature of 20ºC, the set temperature must be as high as 23ºC

Inlet temperature sensor

2.7m

Area measured by the cassette model equipped with "I-See Sensor"360°

sensing

37ºC

25ºC

13ºC

With the “I-See Sensor” plus automatic airflowadjustment mode.

Set temperature is 20ºC (in Heating)

e.g. With the set temperature at 20ºC, a sensible temperature of 20ºC at floor level can be obtained.

With “I-See Sensor”... both the floor temperature and inlet temperature are measured.

The 4-Way Blow Ceiling Cassette with the “I-See Sensor”simultaneously measures the floor and inlet temperatures, providing improved comfort to occupants and increasedenergy savings.

Page 75Page 74

“SensibleTemperature Control”to Prevent Excessive Cooling and Heating

By measuring the inlet temperature and floortemperature, a temperature felt by

the human body (sensible temperature)will be calculated and maintained,

suppressing excessive cooling and heating.

PLA-RP 4-Way Blow Cassette

Page 43: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Page 77

PKA-RP Power Inverter Heat Pump, Wall Mounted System

PKA-RP Standard Inverter Heat Pump, Wall Mounted System

PKA-RP Zubadan Inverter Heat Pump, Wall Mounted System

PKA-RP Power Inverter Heat Pump, High SHF Wall Mounted System

SEZ-KD-VAQ Inverter Heat Pump, Ceiling Concealed Ducted System

PEAD-RP Power Inverter Heat Pump, Ceiling Concealed Ducted System

PEAD-RP Standard Inverter Heat Pump, Ceiling Concealed Ducted System

PEAD-RP Zubadan Inverter Heat Pump, Ceiling Concealed Ducted System

PEA-RP-GAQ Power Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System

PEA-RP-GAQ Standard Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System

SLZ-KA-VAQ Inverter Heat Pump, 600x600 4-Way Blow Ceiling Cassette System

PLA-RP Power Inverter Heat Pump, 4-Way Blow Ceiling Cassette System

PLA-RP Standard Inverter Heat Pump, 4-Way Blow Ceiling Cassette System

PLA-RP Zubadan Inverter Heat Pump, 4-Way Blow Ceiling Cassette System

PCA-RP Power Inverter Heat Pump, Ceiling Suspended System

PCA-RP Standard Inverter Heat Pump, Ceiling Suspended System

PCA-RP-HAQ Power Inverter Heat Pump, Stainless Steel Ceiling Suspended System

PCA-RP-HAQ Standard Inverter Heat Pump, Stainless Steel Ceiling Suspended System

PSA-RP Power Inverter Heat Pump, Floor Standing System

PSA-RP Standard Inverter Heat Pump, Floor Standing System

PHV DXE Heat Pump, Air Curtain

PHV NT Chilled Water Heat Pump, Sensible Cooling Wall Mounted System

Mr Slim Multi-Split Systems Heat Pump

Outdoor Units

Air Handling Unit Controller

Mr Slim Accessories / Optional Extras

82

80

78

84

86

88

90

92

94

96

98

100

102

104

106

108

110

112

114

116

118

120

122

124

130

131

Page 76

Designed tofit anywhere

The Adaptable Mr Slim Range

Simple technologyat its best

Many of our systems have an energy label of A, are registered onthe Energy Technology List and hence qualify for 100% first yearenhanced capital allowances (whole system cost and ‘reasonable’cost of installation).

Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB.UK Conditions: Winter ; indoor 21˚C DB; outdoor -1˚C WB.

For further information please go to www.eca.gov.uk

Contents

Available in a variety of options, the Mr Slim range fits in wherever it’sneeded. Indoor units can be fourway blow cassettes, ducted,floor, wall or ceiling mounted.

Up to four indoor units can then be connected to a single outdoor unitproviding the ideal air conditioningsolution.

Page 44: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

INDOOR UNIT PKA-RP35-50HAL

INDOOR UNIT PKA-RP60-100KAL

Mr

SlimRange

Front View > Side View >

249 5155688

898

55

295

Front View > Side View >

5295

1170

365

74 (855) 241

PK

A-R

PPower Inverter Heat Pump

Dimensions

Page 79

PKA-RP - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) – HRC (A)

INTERCONNECTING CABLE No. CORES

PKA-RP35HAL

4.1 (1.6-5.2)

3.6 (1.6-4.5)

3.5 (1.35-4.4)

3.3 (1.45-4.15)

0.81

3.63 / 3.67

A / A

9-10.5-12

12.7 (1/2”)

6.35 (1/4”)

36-40-43

898

249

295

13

Fed by Outdoor Unit

Single

6

4

PKA-RP50HAL

5.0 (2.5-7.3)

4.6 (2.3-5.6)

4.25 (2.15-6.2)

4.25 (2.1-5.15)

0.72

3.62 / 3.22

A / A

9-10.5-12

12.7 (1/2”)

6.35 (1/4”)

36-40-43

898

249

295

13

Fed by Outdoor Unit

Single

6

4

PKA-RP60KAL

7.0 (2.8-8.2)

6.0 (2.7-6.7)

5.95 (2.4-6.95)

5.5 (2.5-6.15)

0.86

3.98 / 3.90

A / A

18-20-22

15.88 (5/8”)

9.52 (3/8”)

39-42-45

1170

295

365

21

Fed by Outdoor Unit

Single

6

4

PKA-RP71KAL

8.0 (3.5-10.2)

7.1 (3.3-8.1)

6.8 (3.0-8.65)

6.55 (3.05-7.45)

0.78

3.76 / 3.62

A / A

18-20-22

15.88 (5/8”)

9.52 (3/8”)

39-42-45

1170

295

365

21

Fed by Outdoor Unit

Single

6

4

PKA-RP100KAL

11.2 (4.5-14.0)

10.0 (4.9-11.4)

9.5 (3.85-11.9)

9.2 (4.5-10.5)

0.73

3.61 / 3.45

A / A

20-23-26

15.88 (5/8”)

9.52 (3/8”)

41-45-49

1170

295

365

21

Fed by Outdoor Unit

Single

6

4

PUHZ-RP - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SySTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

PUHZ-RP35VHA4

46 / 44 (41)

42

800

300 + 23

600

220-240v, 50Hz

Single

1.13 / 0.98

1.01 / 0.83

5

5.33 / 4.66 [13.4]

-

16

3

50

30

2.5

PUHZ-RP50VHA4

46 / 44 (41)

42

800

300 + 23

600

220-240v, 50Hz

Single

1.38 / 1.43

1.23 / 1.22

5

6.45 / 6.68 [13.4]

-

16

3

50

30

2.5

PUHZ-RP60VHA4

48 / 47 (44)

67

950

330 + 30

943

220-240v, 50Hz

Single

1.76 / 1.54

1.57 / 1.31

5

8.09 / 7.11 [19.4]

-

20

3

50

30

3.5

PUHZ-RP71VHA4

48 / 47 (44)

67

950

330 + 30

943

220-240v, 50Hz

Single

2.13 / 1.96

1.90 / 1.67

5

9.75 / 8.99 [19.4]

-

20

3

50

30

3.5

PUHZ-RP100VKA/YKA

51 / 49 (46)

116 / 124

1050

330 + 30

1338

220-240v, 50Hz / 380-415v,50Hz

Single / 3

3.10 / 2.90

2.76 / 2.47

5

14.15 / 13.25 [27.1]

5.32 / 5.01 [8.6]

32 / 10

3 / 5

75

30

5.0

Wall Mounted System� Flat panel, compact indoor unit design

� Adjustable louvres for uniform air distribution

� Internal pipe connection to wall mountedunit for easy and neat installation

PKA-RP Power Inverter Heat Pump

Technical Information

Page 78

Page 45: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

INDOOR UNIT PKA-RP100KAL

Mr

SlimRange

PK

A-R

PStandard Inverter Heat Pump

Dimensions

Page 81

Front View > Side View >

5295

1170

365

74 (855) 241

PKA-RP - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PKA-RP100KAL

11.2 (4.5-12.5)

9.4 (4.9-11.2)

9.5 (3.85-10.65)

8.65 (4.5-10.3)

0.75

3.21 / 3.01

C / B

20-23-26

15.88 (5/8”)

9.52 (3/8”)

41-45-49

1170

295

365

21

Fed by Outdoor Unit

Single

6

4

PUHZ-P - OUTDOOR UNITS

PUHZ-P100VHA3/YHA

54 / 50 (47)

75 / 77

950

330 + 30

943

220-240v, 50Hz / 380-415v, 50Hz

Single / 3

3.49 / 3.12

3.11 / 2.65

8 / 3

14.81 / 14.15 [28.6]

5.65 / 5.06 [13.6]

32 / 16

3 / 5

50

30

3.0

Wall Mounted System

� Flat panel, compact indoor unit design

� Adjustable louvres for uniform air distribution

� Internal pipe connection to wall mounted unit for easy and neat installation

� 3-phase Standard Inverters now available

PKA-RP Standard Inverter Heat Pump

The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range.

Technical Information

Page 80

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SySTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 20m

Page 46: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

INDOOR UNIT PKA-RP100KAL

Mr

SlimRange

PK

A-R

PZubadan Inverter Heat Pump

Dimensions

Page 83

Front View > Side View >

5295

1170

365

74 (855) 241

Wall Mounted System

PKA-RP Zubadan Inver ter Heat Pump

Technical Information

� Flat panel, compact indoor unit design

� Stable Heating Performance - Full heating capacity at -15°C,a 30% capacity improvement over the next size up Power Inverter

� Expanded Heating Operation - Will work effectively even when the outdoor ambient air temperature is -25°C

� Stable Operation - Utilising the new Flash Injection Circuit the Zubadan models have reduced defrost times and can providecontinuous heating for up to 150 mins

� Quick Start-Up - At -20ºC, full heating capacity is achievedin about 20 mins, improving comfort levels

Zubadan sets a new standard in performance

The Mr Slim Zubadan Inverter heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25ºC.

PKA-RP - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) – HRC (A)

INTERCONNECTING CABLE No. CORES

PKA-RP100KAL

11.2 (4.5-14.0)

10.0 (4.9-11.4)

11.1 (4.45-13.85)

9.2 (4.5-10.5)

0.73

3.61 / 3.41

A / A

20-23-26

15.88 (5/8”)

9.52 (3/8”)

41-45-49

1170

295

365

21

Fed by Outdoor Unit

Single

6

4

PUHZ-HRP - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SySTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

PUHZ-HRP100VHA2/YHA2

52 / 51 (48)

120 / 134

950

330 + 30

1350

220-240v, 50Hz / 380-415v, 50Hz

Single / 3

3.10 / 2.93

4.50 / 2.49

14 / 3

14.15 / 13.39 [35.6]

5.32 / 5.06 [13.6]

40 / 16

3 / 5

75

30

5.5

Page 82

Page 47: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

INDOOR UNIT PKA-RP100KAL

Mr

SlimRange

Front View > Side View >

5295

1170

365

74 (855) 241

PK

A-R

PPower Inverter Heat Pump (High SHF)

Dimensions

Page 85

High SHF Wall Mounted System

� High SHF system for use in server rooms and laboratories

� Flat panel, compact indoor unit design

� Adjustable louvres for uniform air distribution

� Internal pipe connection to wall mountedunit for easy and neat installation

� Duty Standby Operation available using multipleoutdoor units (via PAR-30MAA)

� Able to connect to Run Standby Panel PANEL _RS_SMS (via Procon A1M).A maximum of 8 indoor units can be connected in this way, see page 306for further information

� Gravity drain to rear of indoor unit for safe installation and operation

PKA-RP Power Inverter Heat Pump

Technical Information

Page 84

PKA-RP - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Cooling

SHF (35ºC outdoor / 27ºC DB indoor, 47% relative humidity)

SHF (35ºC outdoor / 24ºC DB indoor, 45% relative humidity)

EER (35ºC outdoor / 27ºC DB indoor, 47% relative humidity)

EER (35ºC outdoor / 24ºC DB indoor, 45% relative humidity)

ENERGy LABEL Cooling

AIRFLOW (m3/min) Lo-Mi-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PKA-RP100KAL

6.0

0.94

0.96

4.29

3.75

A

20-23-26

15.88 (5/8”)

9.52 (3/8”)

41-45-49

1170

295

365

21

Fed by Outdoor Unit

Single

6

4

PUHZ-RP - OUTDOOR UNITS

PUHZ-RP60VHA4

48 / 47 (44)

67

950

330 + 30

943

220-240v, 50Hz

Single

1.4

1.6

5

19.6

20

3

50

30

3.5

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (kW)

Cooling (35ºC outdoor / 27ºC DB indoor, 47% relative humidity)

Cooling (35ºC outdoor / 24ºC DB indoor, 45% relative humidity)

STARTING CURRENT (A)

MAX SySTEM RUNNING CURRENT (A)

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 20m

This new connection provides a low cost split system solution tohigh sensible applications such as server rooms and laboratories.

Page 48: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Upper View >

INDOOR UNIT SEZ-KD25-71VAQ

Front View >

Mr

SlimRange

SEZ

-KD

-VA

Q Inverter Heat Pump

Dimensions

Models A B C D E F

Size 25 700 752 798 660 7 600

Size 35-50 900 952 998 860 9 800

Size 60-71 1100 1152 1198 1060 11 1000

Page 87

Side View >

SEZ-KD-VAQ - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi-Hi

EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Mi2-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) (15Pa) Lo-Mi-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

SUZ-KA-VA2 - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SySTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. CORES

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 7m

SEZ-KD25VAQ

3.0 (0.9-4.5)

2.5 (0.9-3.2)

2.5 (0.75-3.75)

2.5 (0.9-3.15)

0.80

3.61 / 3.33

A / A

6.0-7.0-9.0

5-15-35-50

9.52 (3/8”)

6.35 (1/4”)

23-26-30

790

700

200

18

Fed by Outdoor Unit

Single

6

4

SEZ-KD35VAQ

4.2 (0.9-5.0)

3.7 (1.0-3.9)

3.5 (0.75-4.15)

3.65 (1.0-3.85)

0.78

3.72 / 3.39

A / A

7-9-11

5-15-35-50

9.52 (3/8”)

6.35 (1/4”)

23-28-33

990

700

200

21

Fed by Outdoor Unit

Single

6

4

SEZ-KD50VAQ

6.4 (1.1-7.2)

5.1 (1.1-5.6)

5.3 (0.9-6.0)

5.05 (1.1-5.55)

0.76

3.54 / 3.11

B / B

10-12.5-15

5-15-35-50

12.7 (1/2”)

6.35 (1/4”)

30-34-37

990

700

200

23

Fed by Outdoor Unit

Single

6

4

SEZ-KD60VAQ

7.4 (0.9-8.0)

5.6 (1.1-6.3)

6.15 (0.75-6.65)

5.55 (1.1-6.25)

0.79

3.51 / 3.01

B / B

12-15-18

5-15-35-50

15.88 (5/8”)

6.35 (1/4”)

30-34-38

1190

700

200

27

Fed by Outdoor Unit

Single

6

4

SEZ-KD71VAQ

8.1 (0.9-10.4)

7.1 (0.9-8.3)

6.75 (0.75-8.65)

7.05 (0.9-8.25)

0.74

3.72 / 3.01

A / B

12-16-20

5-15-35-50

15.88 (5/8”)

9.52 (3/8”)

30-35-40

1190

700

200

27

Fed by Outdoor Unit

Single

6

4

SUZ-KA25VA2

46 / 46

33

800

285

550

220-240v, 50Hz

Single

0.83 / 0.75

0.76 / 0.60

3.65

4.05 / 3.45 [8.6]

10

3

20

12

0.8

SUZ-KA35VA2

48 / 47

37

800

285

550

220-240v, 50Hz

Single

1.13 / 1.09

1.03 / 0.87

4.75

5.25 / 5.05 [9.7]

10

3

20

12

1.05

SUZ-KA50VA2

55 / 53

53

840

330

850

220-240v, 50Hz

Single

1.81 / 1.64

1.65 / 1.31

6.75

7.05 / 7.45 [16.7]

20

3

30

30

1.6

SUZ-KA60VA2

55 / 53

53

840

330

850

220-240v, 50Hz

Single

2.11 / 1.86

1.92 / 1.49

9.75

10.45 / 9.05 [16.7]

20

3

30

30

1.8

SUZ-KA71VA2

55 / 55

53

840

330

880

220-240v, 50Hz

Single

2.18 / 2.36

1.98 / 1.89

8.89

9.85 / 9.75 [17.0]

20

3

30

30

1.8

Ceiling Concealed Ducted System

SEZ-KD-VAQ Inverter Heat Pump

Designed for homes, offices, restaurants or shops,the SEZ-KD-VAQ series operates at low noise levels.Its new improved low unit height and lightweightdesign also help to make installation easierand more convenient.

Technical Information

Note: Optional interfaces for M-NET connectivity (MAC-399IF) and group control, fault/run (MAC-397IF) are available. Please see accessories / optional extras section.

Page 86

Page 49: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

INDOOR UNIT PEAD-RP35-140JAQ

Mr

SlimRange

PEA

D-R

PPower Inverter Heat Pump

Dimensions

Page 89

Side View >

Upper View >

Front View >

Air

outletA

irinlet

40

1558

57

10

100

100x(E-1)=F

A

B(Suspension bolt pitch)

C

23

30

57 20 D (Duct)

D

643(Suspension bolt pitch)

Drain pump

Drain pipe(Spontaneous draining)

Drain pipe(O.D. 32)

250

122

33

40

23 10238

32 700

732

136 67

356

100

41

217

178(

Duc

t)

Rear View >

A BPEAD-RP35-50JAQ

PEAD-RP60-71JAQ

900 954

PEAD-RP100-125JAQ

1100 1154

C1000

1200

D860

1060

E9

11

PEAD-RP140JAQ

1400 1454 1500 1360 14

F800

1000

G858

1058

1300 1358

1600 1654 1700 1560 16 1500 1558

Model

PEAD-RP - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi-Hi

PIPE SIZE mm(in) Gas

Liquid

EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Mi2-Mi3-Hi

NOISE (dBA) (50Pa) Lo-Mi-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PEAD-RP140JAQ

16.0 (5.7-18.0)

14.0 (6.2-15.3)

13.6 (4.85-15.3)

12.9 (5.7-14.1)

0.83

3.96 / 3.21

A / A

32-39-46

15.88 (5/8”)

9.52 (3/8”)

35-50-70-100-150

34-38-43

1600

732

250

47

Fed by Outdoor Unit

Single

6

4

PEAD-RP125JAQ

14.0 (5.0-16.0)

12.5 (5.5-14.0)

11.9 (4.25-13.6)

11.5 (5.05-12.9)

0.84

4.00 / 3.24

A / A

29.5-33.5-42

15.88 (5/8”)

9.52 (3/8”)

35-50-70-100-150

33-36-40

1400

732

250

43

Fed by Outdoor Unit

Single

6

4

PEAD-RP100JAQ

11.2 (4.5-14.0)

10.0 (4.9-11.4)

9.5 (3.85-11.9)

9.2 (4.5-10.5)

0.82

4.12 / 3.61

A / A

24-29-34

15.88 (5/8”)

9.52 (3/8”)

35-50-70-100-150

29-34-38

1400

732

250

41

Fed by Outdoor Unit

Single

6

4

PEAD-RP71JAQ

8.0 (3.5-10.2)

7.1 (3.3-8.1)

6.8 (3.0-8.65)

6.55 (3.05-7.45)

0.83

4.00 / 3.50

A / A

17.5-21-25

15.88 (5/8”)

9.52 (3/8”)

35-50-70-100-150

26-30-34

1100

732

250

33

Fed by Outdoor Unit

Single

6

4

PEAD-RP60JAQ

7.0 (2.8-8.2)

6.0 (2.7-6.7)

5.95 (2.4-6.95)

5.5 (2.5-6.15)

0.83

4.00 / 3.75

A / A

14.5-18-21

15.88 (5/8”)

9.52 (3/8”)

35-50-70-100-150

25-29-33

1100

732

250

33

Fed by Outdoor Unit

Single

6

4

PEAD-RP50JAQ

6.0 (2.5-7.3)

5.0 (2.3-5.6)

5.1 (2.15-6.2)

4.6 (2.1-5.15)

0.84

3.85 / 3.23

A / A

12-14.5-17

12.7 (1/2”)

6.35 (1/4”)

35-50-70-100-150

26-31-35

900

732

250

28

Fed by Outdoor Unit

Single

6

4

PEAD-RP35JAQ

4.1 (1.6-5.2)

3.6 (1.6-4.5)

3.5 (1.35-4.4)

3.3 (1.45-4.15)

0.85

3.73 / 3.53

A / A

10-12-14

12.7 (1/2”)

6.35 (1/4”)

35-50-70-100-150

23-27-30

900

732

250

26

Fed by Outdoor Unit

Single

6

4

PUHZ-RP35VHA4

46 / 44 (41)

42

800

300 + 23

600

220-240v, 50Hz

Single

1.10 / 1.02

0.98 / 0.87

5

5.15 / 4.81 [14.1]

-

16

3

50

30

2.5

PUHZ-RP50VHA4

46 / 44 (41)

42

800

300 + 23

600

220-240v, 50Hz

Single

1.56 / 1.55

1.39 / 1.32

5

7.38 / 7.35 [14.4]

-

16

3

50

30

2.5

PUHZ-RP60VHA4

48 / 47 (44)

67

950

330 + 30

943

220-240v, 50Hz

Single

1.75 / 1.60

1.56 / 1.36

5

8.29 / 7.63 [20.6]

-

25

3

50

30

3.5

PUHZ-RP71VHA4

48 / 47 (44)

67

950

330 + 30

943

220-240v, 50Hz

Single

2.00 / 2.03

1.78 / 1.73

5

9.46 / 9.62 [21]

-

25

3

50

30

3.5

PUHZ-RP100VKA/YKA

51 / 49 (46)

116 / 124

1050

330 + 30

1338

220-240v, 50Hz / 380-415v,50Hz

Single / 3

2.72 / 2.77

2.42 / 2.35

5

12.73 / 12.98 [29.2]

5.48 / 5.63 [10.7]

32 / 16

3 / 5

75

30

5.0

PUHZ-RP125VKA/YKA

52 / 50 (47)

116 / 126

1050

330 + 30

1338

220-240v, 50Hz / 380-415v,50Hz

Single / 3

3.50 / 3.86

3.12 / 3.28

5

16.45 / 18.09 [29.3]

7.25 / 7.89 [12.3]

32 / 16

3 / 5

75

30

5.0

PUHZ-RP140VKA/YKA

52 / 50 (47)

118 / 132

1050

330 + 30

1338

220-240v, 50Hz / 380-415v,50Hz

Single / 3

4.04 / 4.36

3.60 / 3.71

5

18.94 / 20.39 [30.8]

8.25 / 8.83 [13.8]

32 / 16

3 / 5

75

30

5.0

PUHZ-RP - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SySTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

Ceiling Concealed Ducted System

PEAD-RP Power Inverter Heat Pump

Technical Information

Page 88

� Reduced height - entire range now only 250mm

� Wider range of external staticpressure settings across entire range

� Reduced noise levels thanks to the use of a newly designed centrifugal fan - as low as 23dBA

� Drain pump included as standard

Page 50: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Mr

SlimRange

PEA

D-R

PStandard Inverter Heat Pump

INDOOR UNIT PEAD-RP35-140JAQ

Dimensions

Page 91

Side View >

Upper View >

Front View >

Air

outletA

irinlet

40

1558

57

10

100

100x(E-1)=F

A

B(Suspension bolt pitch)

C

23

30

57 20 D (Duct)

D

643(Suspension bolt pitch)

Drain pump

Drain pipe(Spontaneous draining)

Drain pipe(O.D. 32)

250

122

33

40

23 10238

32 700

732

136 67

356

100

41

217

178(

Duc

t)

Rear View >

A BPEAD-RP35-50JAQ

PEAD-RP60-71JAQ

900 954

PEAD-RP100-125JAQ

1100 1154

C1000

1200

D860

1060

E9

11

PEAD-RP140JAQ

1400 1454 1500 1360 14

F800

1000

G858

1058

1300 1358

1600 1654 1700 1560 16 1500 1558

Model

PEAD-RP - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi-Hi

PIPE SIZE mm(in) Gas

Liquid

EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Mi2-Mi3-Hi

NOISE (dBA) (50Pa) Lo-Mi-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PEAD-RP140JAQ

16.0 (5.0-18.0)

13.6 (5.5-15.0)

13.6 (4.25-15.3)

12.5 (5.05-13.8)

0.84

3.61 / 3.01

A / B

32-39-46

15.88 (5/8”)

9.52 (3/8”)

35-50-70-100-150

34-38-43

1600

732

250

47

Fed by Outdoor Unit

Single

6

4

PEAD-RP125JAQ

14.0 (5.0-16.0)

12.3 (5.5-14.0)

11.9 (4.25-13.6)

11.3 (5.05-12.9)

0.85

3.62 / 2.91

A / C

29.5-35.5-42

15.88 (5/8”)

9.52 (3/8”)

35-50-70-100-150

33-36-40

1400

732

250

43

Fed by Outdoor Unit

Single

6

4

PEAD-RP100JAQ

11.2 (4.5-12.5)

9.4 (4.9-11.2)

9.5 (3.85-10.65)

8.65 (4.5-10.3)

0.85

3.61 / 3.09

A / B

24-29-34

15.88 (5/8”)

9.52 (3/8”)

35-50-70-100-150

29-34-38

1400

732

250

41

Fed by Outdoor Unit

Single

6

4

PEAD-RP71JAQ

8.0 (0.9-10.2)

7.1 (0.9-8.1)

6.65 (0.75-8.5)

7.05 (0.9-8.05)

0.83

3.92 / 3.38

A / A

17.5-21-25

15.88 (5/8”)

9.52 (3/8”)

35-50-70-100-150

26-30-34

1100

732

250

33

Fed by Outdoor Unit

Single

6

4

PEAD-RP60JAQ

7.0 (0.9-8.0)

5.7 (1.1-6.3)

5.8 (0.75-6.65)

5.65 (1.1-6.25)

0.86

3.61 / 3.39

A / A

14.5-18-21

15.88 (5/8”)

6.35 (1/4”)

35-50-70-100-150

25-29-33

1100

732

250

33

Fed by Outdoor Unit

Single

6

4

PEAD-RP50JAQ

5.9 (0.9-7.2)

4.9 (1.1-5.6)

4.9 (0.75-6.0)

4.85 (1.1-5.55)

0.85

3.64 / 3.22

A / A

12-14.5-17

12.7 (1/2”)

6.35 (1/4”)

35-50-70-100-150

26-31-35

900

732

250

28

Fed by Outdoor Unit

Single

6

4

PEAD-RP35JAQ

4.1 (0.9-5.0)

3.6 (1.0-3.9)

3.4 (0.75-4.15)

3.55 (1.0-3.85)

0.85

3.69 / 3.40

A / A

10-12-14

9.52 (3/8”)

6.35 (1/4”)

35-50-70-100-150

23-27-30

900

732

250

26

Fed by Outdoor Unit

Single

6

4

SUZ-KA35VA2

48 / 47

37

800

285

550

220-240v, 50Hz

Single

1.11 / 1.06

1.01 / 0.85

4.75

5.82 / 5.62 [10.3]

-

16

3

20

12

1.05

SUZ-KA50VA2

55 / 53

53

840

330

850

220-240v, 50Hz

Single

1.62 / 1.52

1.47 / 1.22

6.75

7.74 / 8.14 [17.4]

-

20

3

30

30

1.6

SUZ-KA60VA2

55 / 53

53

840

330

850

220-240v, 50Hz

Single

1.94 / 1.68

1.77 / 1.34

9.75

11.37 / 9.97 [17.6]

-

20

3

30

30

1.8

SUZ-KA71VA2

55 / 55

53

840

330

880

220-240v, 50Hz

Single

2.04 / 2.10

1.86 / 1.68

8.89

10.92 / 10.82 [18.1]

-

20

3

30

30

1.8

PUHZ-P100VHA3/YHA

54 / 50 (47)

75 / 77

950

330 + 30

943

220-240v, 50Hz / 380-415v, 50Hz

Single / 3

3.10 / 3.04

2.76 / 2.58

8 / 3

16.18 / 15.38 [30.7]

5.12 / 5.03 [15.7]

32 / 16

3 / 5

50

30

3.0

PUHZ-P125VHA3/YHA

55 / 51 (48)

99 / 101

950

330 + 30

1350

220-240v, 50Hz / 380-415v, 50Hz

Single / 3

3.87 / 4.22

3.44 / 3.59

11 / 4

19.49 / 20.59 [30.8]

6.29 / 6.85 [15.8]

32 / 16

3 / 5

50

30

4.5

PUHZ-P140VHA3/YHA

56 / 52 (49)

99 / 101

950

330 + 30

1350

220-240v, 50Hz / 380-415v, 50Hz

Single / 3

4.43 / 4.52

3.94 / 3.84

11 / 4

23.23 / 24.38 [32.3]

7.19 / 7.34 [15.8]

40 / 16

3 / 5

50

30

4.5

SUZ-KA / PUHZ-P - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SySTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg)

Ceiling Concealed Ducted System

PEAD-RP Standard Inverter Heat Pump

The Standard Inverter range provides inverter solutions for customerswho want all the benefits that inverters offer, but do not have the budgetavailable for the Power Inverter range.

Notes: All units charged to 7m (35-71), 20m (100) and 30m (125-140) pipe length.

Technical Information

Page 90

� Reduced height - entire range now only 250mm

� Wider range of external static pressure settingsacross entire range

� Reduced noise levels thanks to the use of a newlydesigned centrifugal fan - as low as 23dBA

� Drain pump included as standard

� 3-phase Standard Inverters now available

Page 51: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Mr

SlimRange

PEA

D-R

P Zubadan Inverter Heat Pump

INDOOR UNIT PEAD-RP71-125JAQ

Dimensions

Page 93

A BPEAD-RP71JAQ

PEAD-RP100-125JAQ

1100 1154

C

1200

D

1060

E

11

1400 1454 1500 1360 14

F

1000

G

1058

1300 1358

Model

Side View >

Upper View >

Front View >

Air

outletA

irinlet

40

1558

57

10

100

100x(E-1)=F

A

B(Suspension bolt pitch)

C

23

30

57 20 D (Duct)

D

643(Suspension bolt pitch)

Drain pump

Drain pipe(Spontaneous draining)

Drain pipe(O.D. 32)

250

122

33

40

23 10238

32 700

732

136 67

356

100

41

217

178(

Duc

t)

Rear View >

� Stable Heating Performance - Full heating capacity at -15°C, a 30% capacity improvement over the next size up Power Inverter

� Expanded Heating Operation - Will work effectively even when the outdoor ambient air temperature is -25°C

� Stable Operation - Utilising the new Flash Injection Circuit the Zubadan models have reduced defrost times and can provide continuous heating for up to 150 mins

� Quick Start-Up - At -20ºC, full heating capacity is achievedin about 20 mins, improving comfort levels

Ceiling Concealed Ducted System

PEAD-RP Zubadan Inverter Heat Pump

Technical Information

Page 92

Zubadan sets a new standard in performance

The Mr Slim Zubadan Inverter heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25ºC.

PEAD-RP - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi-Hi

PIPE SIZE mm(in) Gas

Liquid

EXTERNAL STATIC PRESSURE (Pa) Lo-Mi1-Mi2-Mi3-Hi

NOISE (dBA) (50Pa) Lo-Mi-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PEAD-RP125JAQ

14.0 (5.0-16.0)

12.5 (5.5-14.0)

13.85 (4.95-15.85)

11.5 (5.05-12.9)

0.84

3.61 / 3.21

A / A

29.5-33.5-42

15.88 (5/8”)

9.52 (3/8”)

35-50-70-100-150

33-36-40

1400

732

250

43

Fed by Outdoor Unit

Single

6

4

PEAD-RP100JAQ

11.2 (4.5-14.0)

10.0 (4.9-11.4)

11.1 (4.45-13.85)

9.2 (4.5-10.5)

0.82

3.61 / 3.27

A / A

24-29-34

15.88 (5/8”)

9.52 (3/8”)

35-50-70-100-150

29-34-38

1400

732

250

41

Fed by Outdoor Unit

Single

6

4

PEAD-RP71JAQ

8.0 (3.5-10.2)

7.1 (3.3-8.1)

7.9 (3.45-10.1)

6.55 (3.05-7.45)

0.83

3.42 / 3.30

B / A

17.5-21-25

15.88 (5/8”)

9.52 (3/8”)

35-50-70-100-150

26-30-34

1100

732

250

33

Fed by Outdoor Unit

Single

6

4

PUHZ-HRP71VHA2

52 / 51 (48)

120

950

330 + 30

1350

220-240v, 50Hz

Single

2.34 / 2.15

3.39 / 1.83

14

10.99 / 10.15 [31.5]

-

32

3

75

30

5.5

PUHZ-HRP100VHA2/YHA2

52 / 51 (48)

120 / 134

950

330 + 30

1350

220-240v, 50Hz / 380-415,50Hz

Single / 3

3.10 / 3.06

4.50 / 2.60

14 / 3

14.43 / 14.28 [37.7]

6.07 / 6.09 [15.7]

40 / 16

3 / 5

75

30

5.5

PUHZ-HRP125YHA2

52 / 51 (48)

134

950

330 + 30

1350

380-415,50Hz

3

3.88 / 3.89

5.63 / 3.31

3

-

7.84 / 7.94 [15.8]

16

5

75

30

5.5

PUHZ-HRP - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SySTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

Page 52: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

INDOOR UNIT PEA-RP200GAQ

Upper View >

Front View >

Side View >

INDOOR UNIT PEA-RP250GAQ

INDOOR UNIT PEA-RP400-500GAQ

Upper View >

Front View >

Side View >

Upper View >

Front View >

Side View >

Mr

SlimRange

PEA

-RP-G

AQPower Inverter Heat Pump

Dimensions

Page 95

PEA-RP-GAQ - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

EXTERNAL STATIC PRESSURE (Pa)

NOISE (dBA) Lo-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLy

PHASE

POWER INPUT (kW) (nominal)

(UK)

STARTING CURRENT (A)

RUNNING CURRENT (A) [Max]

FUSE RATING (BS88) – HRC (A)

MAINS CABLE No. Cores

INTERCONNECTING CABLE No. CORES

PUHZ-RP-YKA - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

RUNNING CURRENT (A) [Max] Heating/Cooling

FUSE RATING (BS88) – HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

PEA-RP200GAQ

22.4 (9.5-25.0)

19.0 (9.0-22.4)

19.05 (8.1-21.25)

17.5 (8.3-20.6)

0.81

3.45 / 2.84

B / C

52-65

28.58 (1 1/8”)

9.52 (3/8”)

150

48-51

1400

634

400

70

380-415v, 50Hz

3

1.00

0.89

5.6

2.0 [2.4]

6

5

3

PEA-RP250GAQ

27.0 (12.5-31.5)

22.0 (11.2-28.0)

22.95 (10.65-26.8)

20.25 (10.3-25.75)

0.86

3.29 / 2.64

C / D

64-80

28.58 (1 1/8”)

12.7 (1/2”)

150

49-52

1600

634

400

77

380-415v, 50Hz

3

1.18

1.05

5.6

2.3 [2.8]

6

5

3

PUHZ-RP200YKA

59 / 58 (55)

135

1050

330 + 30

1338

380-415v, 50Hz

3

6.5 / 6.7

5.79 / 5.7

5

8.63 / 8.94 [19]

20

5

120

30

7.1

PUHZ-RP250YKA

59 / 58 (55)

141

1050

330 + 30

1338

380-415v, 50Hz

3

8.2 / 8.34

7.3 / 7.09

5

11.01 / 11.23 [21]

25

5

120

30

7.7

PEA-RP400GAQ

44.8 (18.0-50.0)

38.0 (18.0-44.8)

38.1 (15.3-42.5)

34.95 (16.55-41.2)

0.75

3.57 / 2.93

B / C

120

28.58 (1 1/8”) x2

9.52 (3/8”) x2

150

52

1947

764

595

130

380-415v, 50Hz

3

1.55

1.38

8.7

3.8 [4.6]

10

5

3

PEA-RP500GAQ

54.0 (25.0-63.0)

44.0 (22.4-56.0)

45.9 (21.25-53.55)

40.5 (20.6-51.5)

0.77

3.20 / 2.56

D / E

160

28.58 (1 1/8”) x2

12.7 (1/2”) x2

150

53

1947

764

595

133

380-415v, 50Hz

3

2.84

2.53

10

5.4 [6.5]

10

5

3

PUHZ-RP200YKA x2

59 / 58 (55)

135

1050

330 + 30

1338

380-415v, 50Hz

3

12.55 / 12.95

11.17 / 11.01

5

8.63 / 8.94 [19]

20

5

120

30

7.1

PUHZ-RP250YKA x2

59 / 58 (55)

141

1050

330 + 30

1338

380-415v, 50Hz

3

16.88 / 17.16

15.02 / 14.59

5

11.01 / 11.23 [21]

25

5

120

30

7.7

Large Capacity Ceiling Concealed Ducted System

PEA-RP-GAQ Power Inverter Heat Pump

� Twin, triple or quadruple configurations on one outdoor unit, utilising Mr Slim indoor units

� Static pressure of up to 150Pa

Technical Information

Page 94

Page 53: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

INDOOR UNIT PEA-RP200GAQ

Upper View >

Front View >

Side View >

INDOOR UNIT PEA-RP250GAQ

INDOOR UNIT PEA-RP400-500GAQ

Upper View >

Front View >

Side View >

Upper View >

Front View >

Side View >

Mr

SlimRange

PEA

-RP-G

AQStandard Inverter Heat Pump

Dimensions

Page 97

PEA-RP-GAQ - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

EXTERNAL STATIC PRESSURE (Pa)

NOISE (dBA) Lo-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLy

PHASE

POWER INPUT (kW) (nominal)

(UK)

STARTING CURRENT (A)

RUNNING CURRENT (A) [Max]

FUSE RATING (BS88) – HRC (A)

MAINS CABLE No. Cores

INTERCONNECTING CABLE No. CORES

PEA-RP200GAQ

22.4 (9.5-25.0)

19.0 (9.0-22.4)

19.05 (8.1-21.25)

17.5 (8.3-20.6)

0.81

3.04 / 2.64

D / D

52-65

28.58 (1 1/8”)

9.52 (3/8”)

150

48-51

1400

634

400

70

380-415v, 50Hz

3

1.00

0.89

5.6

2.0 [2.4]

6

5

3

PEA-RP250GAQ

27.0 (12.5-31.5)

22.0 (11.2-28.0)

22.95 (10.65-26.8)

20.25 (10.3-25.75)

0.86

3.19 / 2.61

D / D

64-80

28.58 (1 1/8”)

12.7 (1/2”)

150

49-52

1600

634

400

77

380-415v, 50Hz

3

1.18

1.05

5.6

2.3 [2.8]

6

5

3

PUHZ-P200YHA3

59 / 59 (56)

126

950

330+30

1350

380-415v, 50Hz

3

7.36 / 7.21

6.55 / 6.13

5

9.88 / 9.47 [19]

20

5

70

30

5.8

PUHZ-P250YHA3

59 / 59 (56)

135

950

330+30

1350

380-415v, 50Hz

3

8.47 / 8.44

7.54 / 7.17

5

12.0 / 11.0 [21]

25

5

70

30

7.1

PEA-RP400GAQ

44.8 (19.0-50.0)

38.0 (18.0-44.8)

38.1 (16.15-42.5)

34.95 (16.55-41.2)

0.75

3.14 / 2.72

D / D

120

28.58 (1 1/8”) x2

9.52 (3/8”) x2

150

52

1947

764

595

130

380-415v, 50Hz

3

1.55

1.38

8.7

3.8 [4.6]

10

5

3

PEA-RP500GAQ

54.0 (25.0-63.0)

44.0 (22.4-56.0)

45.9 (21.25-53.55)

40.5 (20.6-51.5)

0.77

3.10 / 2.53

D / E

160

28.58 (1 1/8”) x2

12.7 (1/2”) x2

150

53

1947

764

595

133

380-415v, 50Hz

3

2.84

2.53

10

5.4 [ 6.5]

10

5

3

PUHZ-P200YHA3 x2

59 / 59 (56)

126

950

330+30

1350

380-415v, 50Hz

3

14.27 / 13.97

12.7 / 11.88

5

9.88 / 9.47 [19]

20

5

70 per outdoor

30

5.8

PUHZ-P250YHA3 x2

59 / 59 (56)

135

950

330+30

1350

380-415v, 50Hz

3

17.42 / 17.36

15.5 / 14.76

5

12.0 / 11.0 [21]

25

5

70 per outdoor

30

7.1

PUHZ-P-YHA3 - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

RUNNING CURRENT (A) [Max] Heating/Cooling

FUSE RATING (BS88) – HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

Large Capacity Ceiling Concealed Ducted System

PEA-RP-GAQ Standard Inverter Heat Pump

� Twin, triple or quadruple configurations on oneoutdoor unit, utilising Mr Slim indoor units

� Static pressure of up to 150Pa

Technical Information

Page 96

The Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range.

Page 54: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Lower View >

INDOOR UNIT SLZ-KA25-50VAQ

Side View >

Mr

SlimRange

SLZ

-KA

-VA

Q Inverter Heat Pump

Dimensions

Page 99

600x600 4-Way Blow Ceiling Cassette System

SLZ-KA-VAQ - INDOOR UNITS

SLZ-KA-VAQ Inverter Heat Pump

The SLZ-KA-VAQ series is perfect for both residential andsmall business applications, as it offers inverter technologyalongside quiet operation. The compact size of this unit is ideal for 600 by 600mm ceilings and with a depth of208mm, this lightweight unit makes installation a breeze.This unit also comes complete with a long life filter that will last for approximately 2,500 hours.

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi-Hi

DIMENSIONS (mm) (grille) Width

Depth

Height

WEIGHT (kg) Unit

Grille

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

GRILLE REFERENCE

SUZ-KA-VA2 - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SySTEM RUNNING CURRENT (A) [MAX] Heating/Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. CORES

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 7m

SLZ-KA25VAQ

3.2 (0.9-4.5)

2.5 (0.9-3.2)

2.65 (0.75-3.75)

2.5 (0.9-3.15)

0.86

3.76 / 3.68

A / A

8-9-10

9.52 (3/8”)

6.35 (1/4”)

28-31-37

570 (650)

570 (650)

235 (20)

17

3

Fed by Outdoor Unit

Single

6

4

SLP-2AAW

SLZ-KA35VAQ

4.0 (0.9-5.0)

3.5 (1.0-3.9)

3.3 (0.75-4.15)

3.45 (1.0-3.85)

0.77

3.67 / 3.37

A / A

8-9-11

9.52 (3/8”)

6.35 (1/4”)

29-33-38

570 (650)

570 (650)

235 (20)

17

3

Fed by Outdoor Unit

Single

6

4

SLP-2AAW

SLZ-KA50VAQ

5.0 (0.9-6.5)

4.6 (1.1-5.2)

4.15 (0.75-5.4)

4.55 (1.1-5.15)

0.68

3.23 / 3.01

C / B

8-9-11

12.7 (1/2”)

6.35 (1/4”)

30-34-39

570 (650)

570 (650)

235 (20)

17

3

Fed by Outdoor Unit

Single

6

4

SLP-2AAW

SUZ-KA25VA2

46 / 46

33

800

285

550

220-240v, 50Hz

Single

0.85 / 0.68

0.77 / 0.54

3.65

4.05 / 3.45 [8.5]

10

3

20

12

0.8

SUZ-KA35VA2

48 / 47

37

800

285

550

220-240v, 50Hz

Single

1.09 / 1.04

0.99 / 0.83

4.75

5.15 / 4.95 [9.6]

10

3

20

12

1.05

SUZ-KA50VA2

55 / 53

53

840

330

850

220-240v, 50Hz

Single

1.55 / 1.53

1.41 / 1.22

6.75

7.05 / 7.45 [16.7]

20

3

30

30

1.6

Technical InformationNote: Optional interfaces for M-NET connectivity (MAC-399IF) and group control, fault/run (MAC-397IF) are available. Please see accessories / optional extras section.

Page 98

Page 55: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

INDOOR UNIT PLA-RP35-140BA(2)(3)

Models A B

Size 35-71 241 258

Size 100-140 281 298

Upper View >

Lower View >

Side View >

Mr

SlimRange

PLA

-RPPower Inverter Heat Pump

Dimensions

Page 101

� Airflow controllable for ceiling heights up to4.2m, with automatic adjustment of fan speed

� Reduced draft air distribution, withindependent vane control

� Filter lowering operation down to 4m(optional PLP-6BAJ grille required)

� Optional ‘I See Sensor' for energy saving andsmooth temperature control throughout the room

PLA-RP - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi1-Mi2-Hi

DIMENSIONS (mm) Width

(Grille) Depth

Height

WEIGHT (kg) Unit

Panel

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

GRILLE REFERENCE

WIRED REMOTE CONTROLLER REFERENCE

PLA-RP140BA2

16.0 (5.7-18.0)

14.0 (6.2-15.3)

13.6 (4.85-15.3)

12.9 (5.7-14.1)

0.71

3.70 / 3.21

A / A

24-26-29-32

15.88 (5/8”)

9.52 (3/8”)

36-39-42-44

840 (950)

840 (950)

298 (35)

27

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP125BA2

14.0 (5.0-16.0)

12.5 (5.5-14.0)

11.9 (4.25-13.6)

11.5 (5.05-12.9)

0.71

4.00 / 3.41

A / A

22-25-28-31

15.88 (5/8”)

9.52 (3/8”)

34-36-39-41

840 (950)

840 (950)

298 (35)

27

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP100BA3

11.2 (4.5-14.0)

10.0 (4.9-11.4)

9.5 (3.85-11.9)

9.2 (4.5-10.5)

0.74

4.61 / 4.18

A / A

20-23-26-30

15.88 (5/8”)

9.52 (3/8”)

32-34-37-40

840 (950)

840 (950)

298 (35)

26

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP71BA2

8.0 (3.5-10.2)

7.1 (3.3-8.1)

6.8 (3.0-8.65)

6.55 (3.05-7.45)

0.73

4.21 / 3.74

A / A

14-16-18-21

15.88 (5/8”)

9.52 (3/8”)

28-30-32-34

840 (950)

840 (950)

258 (35)

23

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP60BA

7.0 (2.8-8.2)

6.0 (2.7-6.7)

5.95 (2.4-6.95)

5.5 (2.5-6.15)

0.76

3.85 / 3.75

A / A

12-14-16-18

15.88 (5/8”)

9.52 (3/8”)

28-29-31-32

840 (950)

840 (950)

258 (35)

23

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP50BA

6.0 (2.5-7.3)

5.0 (2.3-5.6)

5.1 (2.15-6.2)

4.6 (2.1-5.15)

0.81

3.61 / 3.23

A / A

12-14-16-18

12.7 (1/2”)

6.35 (1/4”)

28-29-31-32

840 (950)

840 (950)

258 (35)

22

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP35BA

4.1 (1.6-5.2)

3.6 (1.6-4.5)

3.5 (1.35-4.4)

3.3 (1.45-4.15)

0.84

3.66 / 3.36

A / A

11-12-13-15

12.7 (1/2”)

6.35 (1/4”)

27-28-29-31

840 (950)

840 (950)

258 (35)

22

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PUHZ-RP35VHA4

46 / 44 (41)

42

800

300 + 23

600

220-240v, 50Hz

Single

1.12 / 1.07

1.00 / 0.91

5

5.15 / 4.98 [13.2]

-

16

3

50

30

2.5

PUHZ-RP50VHA4

46 / 44 (41)

42

800

300 + 23

600

220-240v, 50Hz

Single

1.66 / 1.55

1.48 / 1.32

5

7.62 / 7.08 [13.4]

-

16

3

50

30

2.5

PUHZ-RP60VHA4

48 / 47 (44)

67

950

330 + 30

943

220-240v, 50Hz

Single

1.82 / 1.60

1.62 / 1.36

5

8.34 / 7.31 [19.4]

-

20

3

50

30

3.5

PUHZ-RP71VHA4

48 / 47 (44)

67

950

330 + 30

943

220-240v, 50Hz

Single

1.90 / 1.90

1.69 / 1.62

5

8.76 / 8.71 [19.5]

-

20

3

50

30

3.5

PUHZ-RP100VKA/YKA

51 / 49 (46)

116 / 124

1050

330 + 30

1338

220-240v, 50Hz /380-415v,50Hz

Single / 3

2.43 / 2.39

2.16 / 2.03

5

11.26 / 11.04 [27.5]

4.59 / 4.51 [9]

32 / 10

3 / 5

75

30

5.0

PUHZ-RP125VKA/YKA

52 / 50 (47)

116 / 126

1050

330 + 30

1338

220-240v, 50Hz/380-415v,50Hz

Single / 3

3.50 / 3.67

3.12 / 3.12

5

16.02 / 16.73 [27.5]

6.26 / 6.51 [10.5]

32 / 16

3 / 5

75

30

5.0

PUHZ-RP140VKA/YKA

52 / 50 (47)

118 / 132

1050

330 + 30

1338

220-240v, 50Hz / 380-415v,50Hz

Single / 3

4.32 / 4.36

3.84 / 3.71

5

19.76 / 19.90 [29.1]

7.61 / 7.66 [12.1]

32 / 16

3 / 5

75

30

5.0

PUHZ-RP - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SySTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

4-Way Blow Ceiling Cassette System

PLA-RP Power Inverter Heat Pump

Technical Information

Page 100

Page 56: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

INDOOR UNIT PLA-RP35-140BA(2)

Models A B

Size 35-71 241 258

Size 100-140 281 298

Upper View >

Lower View >

Side View >

Mr

SlimRange

PLA

-RPStandard Inverter Heat Pump

Dimensions

Page 103

SUZ-KA35VA2

48 / 47

37

800

285

550

220-240v, 50Hz

Single

1.04 / 1.09

0.95 / 0.87

4.75

4.97 / 4.77 [9.4]

-

10

3

20

12

1.05

SUZ-KA50VA2

55 / 53

53

840

330

850

220-240v, 50Hz

Single

1.64 / 1.71

1.49 / 1.37

6.75

6.71 / 7.11 [16.4]

-

20

3

30

30

1.6

SUZ-KA60VA2

55 / 53

53

840

330

850

220-240v, 50Hz

Single

1.97 / 1.87

1.79 / 1.50

9.75

10.11 / 8.71 [16.4]

-

20

3

30

30

1.8

SUZ-KA71VA2

55 / 55

53

840

330

880

220-240v, 50Hz

Single

2.19 / 2.07

1.99 / 1.66

8.89

9.46 / 9.36 [16.6]

-

20

3

30

30

1.8

PUHZ-P100VHA3/YHA

54 / 50 (47)

75 / 77

950

330 + 30

943

220-240v, 50Hz /380-415v,50Hz

Single / 3

3.28 / 3.12

2.92 / 2.65

8 / 3

14.92 / 14.16 [28.9]

5.34 / 5.09 [13.9]

32 / 16

3 / 5

50

30

3.0

PUHZ-P125VHA3/YHA

55 / 51 (48)

99 / 101

950

330 + 30

1350

220-240v, 50Hz /380-415v,50Hz

Single / 3

4.11 / 4.09

3.66 / 3.48

11 / 4

18.23 / 18.48 [29]

6.54 / 6.51 [14]

32 / 16

3 / 5

50

30

4.5

PUHZ-P140VHA3/YHA

56 / 52 (49)

99 / 101

950

330 + 30

1350

220-240v, 50Hz /380-415v,50Hz

Single / 3

4.98 / 5.21

4.43 / 4.43

11 / 4

22.50 / 23.71 [30.6]

7.91 / 8.28 [14.1]

32 / 16

3 / 5

50

30

4.5

SUZ-KA / PUHZ-P - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SySTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg)

Notes: All units charged to 7m (35-71), 20m (100) and 30m (125-140) pipe length.

PLA-RP - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi1-Mi2-Hi

DIMENSIONS (mm) Width

(Grille) Depth

Height

WEIGHT (kg) Unit

Panel

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

GRILLE REFERENCE

WIRED REMOTE CONTROLLER REFERENCE

PLA-RP140BA2

16.0 (5.0-18.0)

13.6 (5.5-15.0)

13.6 (4.25-15.3)

12.5 (5.05-13.8)

0.71

3.21 / 2.61

C / D

24-26-29-32

15.88 (5/8”)

9.52 (3/8”)

36-39-42-44

840 (950)

840 (950)

298 (35)

27

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP125BA

14.0 (5.0-16.0)

12.3 (5.5-14.0)

11.9 (4.25-13.6)

11.3 (5.05-12.9)

0.71

3.41 / 3.01

B / B

22-25-28-31

15.88 (5/8”)

9.52 (3/8”)

34-36-39-41

840 (950)

840 (950)

298 (35)

25

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP100BA

11.2 (4.5-12.5)

9.4 (4.9-11.2)

9.5 (3.85-10.65)

8.65 (4.5-10.3)

0.74

3.41 / 3.01

B / B

20-23-26-30

15.88 (5/8”)

9.52 (3/8”)

32-34-37-40

840 (950)

840 (950)

298 (35)

25

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP71BA

8.0 (0.9-10.2)

7.1 (0.9-8.1)

6.65 (0.75-8.5)

7.05 (0.9-8.05)

0.73

3.65 / 3.43

A / A

14-16-18-21

15.88 (5/8”)

9.52 (3/8”)

28-30-32-34

840 (950)

840 (950)

258 (35)

23

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP60BA

6.9 (0.9-8.0)

6.1 (1.1-6.3)

5.75 (0.75-6.65)

6.05 (1.1-6.25)

0.76

3.50 / 3.26

B / A

12-14-16-18

15.88 (5/8”)

6.35 (1/4”)

28-29-31-32

840 (950)

840 (950)

258 (35)

23

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP50BA

6.0 (0.9-7.2)

5.5 (1.1-5.6)

5.0 (0.75-6.0)

5.45 (1.1-5.55)

0.81

3.66 / 3.22

A / A

12-14-16-18

12.7 (1/2”)

6.35 (1/4”)

28-29-31-32

840 (950)

840 (950)

258 (35)

22

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP35BA

4.1 (0.9-5.0)

3.6 (1.0-3.9)

3.4 (0.75-4.15)

3.55 (1.0-3.85)

0.84

3.94 / 3.30

A / A

11-12-13-15

9.52 (3/8”)

6.35 (1/4”)

27-28-29-31

840 (950)

840 (950)

258 (35)

22

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

4-Way Blow Ceiling Cassette System

PLA-RP Standard Inverter Heat Pump

The new Standard Inverter range provides inverter solutions for customers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range.

� Airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed

� Reduced draft air distribution, with independent vane control

� Filter lowering operation down to 4m(optional PLP-6BAJ grille required)

� Optional ‘I See Sensor’ for energy saving andsmooth temperature control throughout the room

� 3-phase Standard Inverters now available

Technical Information

Page 102

Page 57: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

INDOOR UNIT PLA-RP71-125BA(2)(3)

Models A B

Size 71 241 258

Size 100-125 281 298

Upper View >

Lower View >

Side View >

Mr

SlimRange

PLA

-RPZubadan Inverter Heat Pump

Dimensions

Page 105

4-Way Blow Ceiling Cassette System

PLA-RP Zubadan Inver ter Heat Pump

Technical Information

� Stable Heating Performance - Full heating capacity at -15°C, a 30% capacity improvement over the next size up Power Inverter

� Expanded Heating Operation - Will work effectively evenwhen the outdoor ambient air temperature is -25°C

� Stable Operation - Utilising the new Flash Injection Circuit the Zubadan models have reduced defrost times and can provide continuous heating for up to 150 mins

� Quick Start-Up - At -20ºC, full heating capacity is achieved in about 20 mins, improving comfort levels

The Mr Slim Zubadan Inverter heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25ºC.

Zubadan sets a new standard in performance

Page 104

PLA-RP - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal) [3 Phase]

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi1-Mi2-Hi

DIMENSIONS (mm) Width

(Grille) Depth

Height

WEIGHT (kg) Unit

Panel

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

GRILLE REFERENCE

WIRED REMOTE CONTROLLER REFERENCE

PLA-RP125BA2

14.0 (5.0-16.0)

12.5 (5.5-14.0)

13.85 (4.95-15.85)

11.5 (5.05-12.9)

0.71

3.92 / 3.30

A / A

22-25-28-31

15.88 (5/8”)

9.52 (3/8”)

34-36-39-41

840 (950)

840 (950)

298 (35)

27

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP100BA3

11.2 (4.5-14.0)

10.0 (4.9-11.4)

11.1 (4.45-13.85)

9.2 (4.5-10.5)

0.74

4.41 / 4.10 [4.31 / 4.00]

A / A

20-23-26-30

15.88 (5/8”)

9.52 (3/8”)

32-34-37-40

840 (950)

840 (950)

298 (35)

26

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PLA-RP71BA2

8.0 (4.5-10.2)

7.1 (4.9-8.1)

7.9 (4.45-10.1)

6.55 (4.5-7.45)

0.73

4.21 / 3.66

A / A

14-16-18-21

15.88 (5/8”)

9.52 (3/8”)

28-30-32-34

840 (950)

840 (950)

258 (35)

23

6

Fed by Outdoor Unit

Single

6

4

PLP-6BA

PAR-21MAA

PUHZ-HRP71VHA2

52 / 51 (48)

120

950

330 + 30

1350

220-240v, 50Hz

Single

1.90 / 1.94

2.76 / 1.65

14

8.76 / 8.89 [30]

-

32

3

75

30

5.5

PUHZ-HRP100VHA2/YHA2

52 / 51 (48)

120 / 134

950

330 + 30

1350

220-240v, 50Hz / 380-415,50Hz

Single / 3

2.54 / 2.44 [2.60 / 2.50]

3.68 / 2.07 [3.77 / 2.13]

14 / 3

11.76 / 11.26 [36]

4.86 / 4.69 [14]

40 / 16

3 / 5

75

30

5.5

PUHZ-HRP125YHA2

52 / 51 (48)

134

950

330 + 30

1350

380-415,50Hz

3

3.57 / 3.79

5.18 / 3.22

3

-

6.37 / 6.70 [14]

16

5

75

30

5.5

PUHZ-HRP - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (kW) Heating/Cooling (nominal)

[3 Phase] Heating/Cooling (UK)

STARTING CURRENT (A)

SySTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

Page 58: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Mr

SlimRange

PC

A-R

PPower Inverter Heat Pump

Dimensions

Page 107

84

88

195 230

57

254

476

680

182 85 878

960 2 2 853

5

10 51

236

PCA-RP50KAQ

8488

195 230

5725

447

668

0

182 851198

1280 221173 5

1

510

51

236

PCA-RP60-71KAQ

8488

195 230

5725

447

668

0

182 851518

1600 221493 5

1051

236

PCA-RP100-140KAQ

Lower View >

Side View >Front View >

Lower View >

Side View >Front View >

Lower View >

Side View >Front View >

PCA-RP - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi1-Mi2-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PCA-RP140KAQ

16.0 (5.7-18.0)

14.0 (6.2-15.3)

13.6 (4.85-15.3)

12.9 (5.7-14.1)

0.71

3.61 / 3.21

A / A

24-26-29-32

15.88 (5/8”)

9.52 (3/8”)

41-43-45-48

1600

680

230

39

Fed by Outdoor Unit

Single

6

4

PCA-RP125KAQ

14.0 (5.0-16.0)

12.5 (5.5-14.0)

11.9 (4.25-13.6)

11.5 (5.05-12.9)

0.72

3.61 / 3.22

A / A

23-25-27-29

15.88 (5/8”)

9.52 (3/8”)

39-41-43-45

1600

680

230

38

Fed by Outdoor Unit

Single

6

4

PCA-RP100KAQ

11.2 (4.5-14.0)

10.0 (4.9-11.4)

9.5 (3.85-11.9)

9.2 (4.5-10.5)

0.77

3.71 / 3.80

A / A

22-24-26-28

15.88 (5/8”)

9.52 (3/8”)

37-39-41-43

1600

680

230

36

Fed by Outdoor Unit

Single

6

4

PCA-RP71KAQ

8.0 (3.5-10.2)

7.1 (3.3-8.1)

6.8 (3.0-8.65)

6.55 (3.05-7.45)

0.76

3.62 / 3.62

A / A

16-17-18-20

15.88 (5/8”)

9.52 (3/8”)

35-37-39-41

1280

680

230

32

Fed by Outdoor Unit

Single

6

4

PCA-RP60KAQ

7.0 (2.8-8.2)

6.0 (2.7-6.7)

5.95 (2.4-6.95)

5.5 (2.5-6.15)

0.81

3.61 / 4.00

A / A

15-16-17-19

15.88 (5/8”)

9.52 (3/8”)

33-35-37-40

1280

680

230

32

Fed by Outdoor Unit

Single

6

4

PCA-RP50KAQ

5.5 (2.5-6.6)

5.0 (2.3-5.6)

4.7 (2.15-5.6)

4.6 (2.1-5.15)

0.79

3.62 / 3.21

A / A

10-11-13-15

12.7 (1/2”)

6.35 (1/4”)

32-34-37-40

960

680

230

25

Fed by Outdoor Unit

Single

6

4

Ceiling Suspended System

PCA-RP Power Inverter Heat Pump

� Indoor unit designed for direct ceiling suspension

� Flush to wall installation for concealmentof service connections

PUHZ-RP50VHA4

46 / 44 (41)

42

800

300 + 23

600

220-240v, 50Hz

Single

1.52 / 1.56

1.35 / 1.33

5

6.96 / 7.14 [13.4]

-

16

3

50

30

2.5

PUHZ-RP60VHA4

48 / 47 (44)

67

950

330 + 30

943

220-240v, 50Hz

Single

1.94 / 1.50

1.73 / 1.28

5

8.82 / 6.84 [19.4]

-

20

3

50

30

3.5

PUHZ-RP71VHA4

48 / 47 (44)

67

950

330 + 30

943

220-240v, 50Hz

Single

2.21 / 1.96

1.97 / 1.67

5

10.06 / 8.94 [19.4]

-

20

3

50

30

3.5

PUHZ-RP100VKA/YKA

51 / 49 (46)

116 / 124

1050

330 + 30

1338

220-240v, 50Hz / 380-415v,50Hz

Single / 3

3.02 / 2.63

2.69 / 2.24

5

13.78 / 12.04 [27.2]

5.25 / 4.63 [8.7]

32 / 10

3 / 5

75

30

5.0

PUHZ-RP125VKA/YKA

52 / 50 (47)

116 / 126

1050

330 + 30

1338

220-240v, 50Hz / 380-415v,50Hz

Single / 3

3.88 / 3.88

3.45 / 3.30

5

17.66 / 17.66 [27.3]

6.67 / 6.67 [10.3]

32 / 16

3 / 5

75

30

5.0

PUHZ-RP140VKA/YKA

52 / 50 (47)

118 / 132

1050

330 + 30

1338

220-240v, 50Hz / 380-415v,50Hz

Single / 3

4.43 / 4.36

3.94 / 3.71

5

20.13 / 19.82 [28.9]

7.63 / 7.52 [11.9]

32 / 16

3 / 5

75

30

5.0

PUHZ-RP - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SySTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

Technical Information

Page 106

Page 59: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Mr

SlimRange

PC

A-R

PStandard Inverter Heat Pump

Dimensions

Page 109

84

88

195 230

57

254

476

680

182 85 878

960 2 2 853

5

10 51

236

PCA-RP50KAQ

8488

195 230

5725

447

668

0

182 851198

1280 221173 5

1

510

51

236

PCA-RP60-71KAQ

8488

195 230

5725

447

668

0

182 851518

1600 221493 5

1051

236

PCA-RP100-140KAQ

Lower View >

Side View >Front View >

Lower View >

Side View >Front View >

Lower View >

Side View >Front View >SUZ-KA50VA2

55 / 53

53

840

330

850

220-240v, 50Hz

Single

1.71 / 1.66

1.56 / 1.33

6.75

6.72 / 7.12 [16.4]

-

20

3

30

30

1.6

SUZ-KA60VA2

55 / 53

53

840

330

850

220-240v, 50Hz

Single

2.02 / 1.77

1.84 / 1.42

9.75

10.14 / 8.74 [16.4]

-

20

3

30

30

1.8

SUZ-KA71VA2

55 / 55

53

840

330

880

220-240v, 50Hz

Single

1.96 / 2.06

1.78 / 1.65

8.89

9.37 / 9.27 [16.5]

-

20

3

30

30

1.8

PUHZ-P100VHA3/YHA

54 / 50 (47)

75 / 77

950

330 + 30

943

220-240v, 50Hz / 380-415v,50Hz

Single / 3

3.28 / 3.13

2.92 / 2.66

8 / 3

15.73 / 14.09 [28.7]

5.33 / 5.09 [13.7]

32 / 16

3 / 5

50

30

3.0

PUHZ-P125VHA3/YHA

55 / 51 (48)

99 / 101

950

330 + 30

1350

220-240v, 50Hz / 380-415v,50Hz

Single / 3

4.12 / 4.09

3.67 / 3.48

11 / 4

18.55 / 18.42 [28.8]

6.54 / 6.50 [13.8]

32 / 16

3 / 5

50

30

4.5

PUHZ-P140VHA3/YHA

56 / 52 (49)

99 / 101

950

330 + 30

1350

220-240v, 50Hz / 380-415v,50Hz

Single / 3

4.69 / 4.84

4.17 / 4.11

11 / 4

21.09 / 21.97 [30.4]

7.44 / 7.67 [13.9]

32 / 16

3 / 5

50

30

4.5

SUZ-KA / PUHZ-P - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (kW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SySTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg)

Notes: All units charged to 7m (50-71), 20m (100) and 30m (125-140) pipe length.

PCA-RP - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Mi1-Mi2-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Mi1-Mi2-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PCA-RP140KAQ

16.0 (5.0-18.0)

13.6 (5.5-15.0)

13.6 (4.25-15.3)

12.5 (5.05-13.8)

0.71

3.41 / 2.81

B / C

24-26-29-32

15.88 (5/8”)

9.52 (3/8”)

41-43-45-48

1600

680

230

39

Fed by Outdoor Unit

Single

6

4

PCA-RP125KAQ

14.0 (5.0-16.0)

12.3 (5.5-14.0)

11.9 (4.25-13.6)

11.3 (5.05-12.9)

0.72

3.40 / 3.01

C / B

23-25-27-29

15.88 (5/8”)

9.52 (3/8”)

39-41-43-45

1600

680

230

38

Fed by Outdoor Unit

Single

6

4

PCA-RP100KAQ

11.2 (4.5-12.5)

9.4 (4.9-11.2)

9.5 (3.85-10.65)

8.65 (4.5-10.3)

0.77

3.41 / 3.00

B / C

22-24-26-28

15.88 (5/8”)

9.52 (3/8”)

37-39-41-43

1600

680

230

36

Fed by Outdoor Unit

Single

6

4

PCA-RP71KAQ

7.9 (0.9-10.2)

7.1 (0.9-8.1)

6.55 (0.75-8.5)

7.05 (0.9-8.05)

0.76

4.03 / 3.45

A / A

16-17-18-20

15.88 (5/8”)

9.52 (3/8”)

35-37-39-41

1280

680

230

32

Fed by Outdoor Unit

Single

6

4

PCA-RP60KAQ

6.9 (0.9-8.0)

5.7 (1.1-6.3)

5.75 (0.75-6.65)

5.65 (1.1-6.25)

0.81

3.42 / 3.22

B / A

15-16-17-19

15.88 (5/8”)

6.35 (1/4”)

33-35-37-40

1280

680

230

32

Fed by Outdoor Unit

Single

6

4

PCA-RP50KAQ

5.5 (0.9-6.6)

5.0 (1.1-5.6)

4.55 (0.75-5.5)

4.95 (1.1-5.55)

0.79

3.22 / 3.01

C / B

10-11-13-15

12.7 (1/2”)

6.35 (1/4”)

32-34-37-40

960

680

230

25

Fed by Outdoor Unit

Single

6

4

Ceiling Suspended System

PCA-RP Standard Inverter Heat Pump

The new Standard Inverter range provides inverter solutions forcustomers who want all the benefits that inverters offer, but donot have the budget available for the Power Inverter range.

Technical Information

� Indoor unit designed for direct ceiling suspension

� Flush to wall installation for concealmentof service connections

� 3-phase Standard Invertersnow available

Page 108

Page 60: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

INDOOR UNIT PCA-RP71HAQ

INDOOR UNIT PCA-RP125HAQ

Front View >

Side View >

Lower View >

12241180

986

1136

110102

75

1136

650

258

650

280

1608

13701520

110102

75

1564

1520

650

258

650

280

Side View >

Front View >

Lower View >

Mr

SlimRange

PC

A-R

P-H

AQPower Inverter Heat Pump

Dimensions

Page 111

PCA-RP71HAQ

7.6 (3.5-10.2)

7.1 (3.3-8.1)

6.45 (3.0-8.65)

6.55 (3.05-7.45)

0.74

3.41 / 3.21

B / A

17-19

15.88 (5/8”)

9.52 (3/8”)

34-38

1136

650

280

41

Fed by Outdoor Unit

Single

6

4

PCA-RP125HAQ

13.8 (5.0-16.0)

12.5 (5.5-14.0)

11.75 (4.25-13.6)

11.5 (5.05-12.9)

0.77

3.41 / 3.22

B / A

30-38

15.88 (5/8”)

9.52 (3/8”)

44-50

1520

650

280

56

Fed by Outdoor Unit

Single

6

4

PCA-RP-HAQ - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

Stainless Steel Ceiling Suspended System

PCA-RP-HAQ Power Inverter Heat Pump

PUHZ-RP71VHA4

48 / 47 (44)

67

950

330 + 30

943

220-240v, 50Hz

Single

2.23 / 2.21

1.98 / 1.88

5

10.02 / 9.93 [19.4]

-

20

3

50

30

3.5

PUHZ-RP125VKA/YKA

52 / 50 (47)

116 / 126

1050

330 + 30

1338

220-240v, 50Hz / 380-415v, 50Hz

Single / 3

4.05 / 3.88

3.60 / 3.30

5

18.18 / 17.42 [27.7]

7.14 / 6.87 [10.7]

32 / 16

3 / 5

75

30

5.0

PUHZ-RP - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (KW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SySTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

The PCA-RP-HAQ series is a ceiling suspended unit ideal for use in kitchen environments. The external casing is made of durable stainless steel that is resistant to oil and smoke, ensuring that the unit can be easily cleaned at all times.

� High performance oil mist filter

� Easy maintenance - fan casing can be separated into different sections allowing easy cleaning. The drain pan can also be cleaned easily on-site as the pipe connector can be quickly removed

� Optional decoration covers

Technical Information

Page 110

Page 61: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

INDOOR UNIT PCA-RP125HAQ

1608

13701520

110102

75

1564

1520

650

258

650

280

Side View >

Front View >

Lower View >

Mr

SlimRange

PC

A-R

P-H

AQStandard Inverter Heat Pump

Dimensions

Page 113

PCA-RP125HAQ

13.8 (5.0-16.0)

12.3 (5.5-14.0)

11.75 (4.25-13.6)

11.3 (5.05-12.9)

0.78

3.21 / 2.81

C / C

30-38

15.88 (5/8”)

9.52 (3/8”)

44-50

1520

650

280

56

Fed by Outdoor Unit

Single

6

4

PCA-RP-HAQ - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

Stainless Steel Ceiling Suspended System

PCA-RP-HAQ Standard Inverter Heat Pump

PUHZ-P125VHA3/YHA

55 / 51 (48)

99 / 101

950

330 + 30

1350

220-240v, 50Hz / 380-415v, 50Hz

Single / 3

4.30 / 4.38

3.83 / 3.72

11 / 4

19.11 / 19.47 [29.2]

6.73 / 6.86 [14.2]

32 / 16

3 / 5

50

30

4.5

PUHZ-P - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (KW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SySTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

The new Standard Inverter range provides inverter solutions forcustomers who want all the benefits that inverters offer, but do not have the budget available for the Power Inverter range.

� High performance oil mist filter

� Easy maintenance - fan casing can be separated into different sections allowing easy cleaning. The drain pan can also be cleaned easily on-site as the pipe connector can be quickly removed

� Optional decoration covers

� 3-phase Standard Inverters now available

Technical Information

Page 112

Page 62: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

INDOOR UNIT PSA-RP71GA

INDOOR UNIT PSA-RP100-125GA

Front View > Side View > Upper View >

Front View > Side View > Upper View >

Mr

SlimRange

PSA

-RPPower Inverter Heat Pump

Dimensions

Page 115

PSA-RP71GA

7.6 (3.5-10.2)

7.1 (3.3-8.1)

6.45 (3.0-8.65)

6.55 (3.05-7.45)

0.73

3.41 / 3.23

B / A

15-18

15.88 (5/8”)

9.52 (3/8”)

40-45

600

270

1900

43

Fed by Outdoor Unit

Single

6

4

PSA-RP100GA

11.2 (4.5-14.0)

10.0 (4.9-11.4)

9.5 (3.85-11.9)

9.2 (4.5-10.5)

0.81

3.41 / 3.34

B / A

24-31

15.88 (5/8”)

9.52 (3/8”)

44-49

600

350

1900

51

Fed by Outdoor Unit

Single

6

4

PSA-RP - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK )

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

Floor Standing System

PSA-RP Power Inverter Heat Pump

PUHZ-RP71VHA4

48 / 47 (44)

67

950

330 + 30

943

220-240v, 50Hz

Single

2.23 / 2.20

1.98 / 1.87

5

9.98 / 9.85 [19.7]

-

20

3

50

30

3.5

PUHZ-RP100VKA/YKA

51 / 49 (46)

116 / 124

1050

330 + 30

1338

220-240v, 50Hz / 380-415v, 50Hz

Single / 3

3.28 / 2.99

2.92 / 2.54

5

14.69 / 13.39 [27.6]

5.83 / 5.37 [9.1]

32 / 10

3 / 5

75

30

5.0

PSA-RP125GA

14.0 (5.0-16.0)

12.4 (5.5-14.0)

11.9 (4.25-13.6)

11.4 (5.05-12.9)

0.75

3.41 / 3.01

B / B

26-33

15.88 (5/8”)

9.52 (3/8”)

46-51

600

350

1900

51

Fed by Outdoor Unit

Single

6

4

PUHZ-RP125VKA/YKA

52 / 50 (47)

116 / 126

1050

330 + 30

1338

220-240v, 50Hz / 380-415v, 50Hz

Single / 3

4.11 / 4.12

3.66 / 3.50

5

18.40 / 18.44 [27.7]

7.24 / 7.25 [10.7]

32 / 16

3 / 5

75

30

5.0

PUHZ-RP - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (KW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SySTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg) - 30m

Technical InformationNote:When used with a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.

The PSA-RP Floor Standing System complements the MitsubishiElectric range of indoor units. The sleek, modern design of this unitis ideal for numerous applications including bars and restaurants.

� Built in controller

Page 114

Page 63: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

INDOOR UNIT PSA-RP100-125GA

Front View > Side View > Upper View >

Mr

SlimRange

PSA

-RPStandard Inverter Heat Pump

Dimensions

Page 117

PSA-RP125GA

14.0 (5.0-16.0)

12.3 (5.5-14.0)

11.9 (4.25-13.6)

11.3 (5.05-12.9)

0.76

2.81 / 2.81

D / C

26-33

15.88 (5/8”)

9.52 (3/8”)

46-51

600

350

1900

51

Fed by Outdoor Unit

Single

6

4

PSA-RP - INDOOR UNITS

MODEL REFERENCE

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

SHF (nominal & UK)

COP / EER (nominal)

ENERGy LABEL Heating/Cooling

AIRFLOW (m3/min) Lo-Hi

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA) Lo-Hi

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

ELECTRICAL SUPPLy

PHASE

FUSE RATING (BS88) - HRC (A)

INTERCONNECTING CABLE No. CORES

PSA-RP Standard Inverter Heat Pump

PUHZ-P125VHA3/YHA

55 / 51 (48)

99 / 101

950

330 + 30

1350

220-240v, 50Hz / 380-415v, 50Hz

Single / 3

4.98 / 4.38

4.43 / 3.72

11 / 4

22.08 / 19.42 [29.2]

7.78 / 6.84 [14.2]

32 / 16

3 / 5

50

30

4.5

PSA-RP100GA

11.2 (4.5-12.5)

9.4 (4.9-11.2)

9.5 (3.85-10.65)

8.65 (4.5-10.3)

0.83

3.41 / 3.01

B / B

24-31

15.88 (5/8”)

9.52 (3/8”)

44-49

600

350

1900

51

Fed by Outdoor Unit

Single

6

4

PUHZ-P100VHA3/YHA

54 / 50 (47)

75 / 77

950

330 + 30

943

220-240v, 50Hz / 380-415v, 50Hz

Single / 3

3.28 / 3.12

2.92 / 2.65

8 / 3

14.55 / 13.84 [29.1]

5.23 / 4.97 [14.1]

32 / 16

3 / 5

50

30

3.0

PUHZ-P - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA) Heating/Cooling (silent)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

SySTEM POWER INPUT (KW) Heating/Cooling (nominal)

Heating/Cooling (UK)

STARTING CURRENT (A)

SySTEM RUNNING CURRENT (A) Single Phase

Heating/Cooling [MAX] 3 Phase

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

MAX PIPE LENGTH (m)

MAX HEIGHT DIFFERENCE (m)

CHARGE R410A (kg)

Floor Standing System

Technical Information

The Standard Inverter range provides inverter solutions for customerswho want all the benefits that inverters offer, but do not have the budgetavailable for the Power Inverter range.

The PSA-RP Floor Standing System complements the Mitsubishi Electricrange of indoor units. The sleek, modern design of this unit is ideal for numerous applications including bars and restaurants.

� Built in controller

� 3-phase Standard Inverters now available

Note:When used with a Mr Slim Multi-Split system. PSA-RP cannot be connected with indoor units of different type.

Page 116

Notes: All units charged to 20m (100) and 30m (125) pipe length.

Page 64: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PHV1000 DXE PHV1500 DXE PHV2000 DXE

AIR CURTAIN PHV1000/1500/2000R DXE

Mr

SlimRange

Dimensions

PH

V D

XEAir Curtain

AIR CURTAIN PHV1000/1500/2000 DXE

Rear View >

Upper View >

Page 119

Side View >

Rear View >

Upper View >

Side View >

PHV DXE Heat Pump Air CurtainHeat Pump Air Curtain System

In collaboration with Thermoscreens®, Mitsubishi Electric have developed a range of air cur tains that can beconnected to our Power Inver ter heat pumps, as opposed to the more traditional direct electric methodassociated with air cur tains.

� Reduced CO2 emissions (up to 67%)

� Reduced Running Costs (up to 67%)

� 2.5 year payback period against equivalentElectric system

� Inverter technology (does not waste energy)

� Range of different sizes to suit every application

� Allows open door policy in retail outletswhilst being energy efficient

� Clean environment - protection from dust, fumes etc

� Comfortable climate for customers

� Easy to install and maintain

Page 118

PHV DXE - RECESSED

MODEL REFERENCE

DIMENSIONS (mm) (WxDxH)

SUPPLy (50Hz)

HEAT OUTPUT (kW) 100% / 50%

COP 100% / 50%

LOADING (amps)

VELOCITy (m/s)

AIR VOLUME (m3/h)

WEIGHT (kg)

NOISE dB(A) @ 3m

MAX. MOUNTING HEIGHT (m)

OUTDOOR UNIT MODEL

PHV1500R DXE HO

1650x436x296

415V*1

14.4 / 8.3

2.5 / 3.7

12.7*1

9

2600

67

58

3.5

PUHZ-RP140VKA/yKA

PHV2000R DXE LO

2240x436x296

415V*2

14.1 / 7.9

2.9 / 3.7

15.7*2

9.5

3300

85

59

3.5

PUHZ-RP100VKA/yKA

PHV2000R DXE HO

2240x436x296

415V*2

21.3 / 11.2

2.4 / 3.2

15.7*2

9

3130

88

59

3.5

PUHZ-RP200yKA

Technical Information

PHV DXE - FREE STANDING

MODEL REFERENCE

DIMENSIONS (mm) (WxDxH)

SUPPLy (50Hz)

HEAT OUTPUT (kW) 100% / 50%

COP 100% / 50%

LOADING (amps)

VELOCITy (m/s)

AIR VOLUME (m3/h)

WEIGHT (kg)

NOISE dB(A) @ 3m

MAX. MOUNTING HEIGHT (m)

OUTDOOR UNIT MODEL

PHV1500 DXE HO

1746x377x255

415V*1

14.4 / 8.3

2.5 / 3.7

12.7*1

9

2600

60

58

3.75

PUHZ-RP140VKA/yKA

PHV2000 DXE LO

2296x377x255

415V*2

14.1 / 7.9

2.9 / 3.7

15.7*2

9.5

3300

78

59

3.75

PUHZ-RP100VKA/yKA

PHV2000 DXE HO

2296x377x255

415V*2

21.3 / 11.2

2.4 / 3.2

15.7*2

9

3130

80

59

3.75

PUHZ-RP200yKA

Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for PHV1000 DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.

HEAT PUMP OUTDOOR UNITSMODEL REFERENCE

DIMENSIONS (mm) (WxDxH)

SUPPLy (50Hz)

MAX. CURRENT (A)

FUSE SIZE HRC (BS88)

MAX. PIPE RUN Length (m)

Height (m)

PIPE SIZES Gas mm(in)

Liquid mm(in)

INTERCONNECTING CABLE

PUHZ-RP100VKA/YKA

1050x330+30x1338

230V / 415V

26.5 / 8

32 / 10

50

30

15.88 (5/8)

9.52 (3/8)

2 core

PHV1500R DXE LO

1650x436x296

415V*1

10.1 / 5.6

2.3 / 3.4

12.7*1

9

2500

66

58

3.5

PUHZ-RP71VHA4

PHV1000R DXE HO

1150x436x296

415V*1

8.6 / 5.34

2.4 / 3.15

7.8*1

9

1400

45

56

3.5

PUHZ-RP71VHA4

PHV1500 DXE LO

1746x377x255

415V*1

10.1 / 5.6

2.3 / 3.4

12.7*1

9

2500

59

58

3.75

PUHZ-RP71VHA4

PHV1000 DXE HO

1196x377x255

415V*1

8.6 / 5.34

2.4 / 3.15

7.8*1

9

1400

39

56

3.75

PUHZ-RP71VHA4

PUHZ-RP71VHA4

950x330+30x943

230V

19

20

50

30

15.88 (5/8)

9.52 (3/8)

2 core

PUHZ-RP140VKA/YKA

1050x330+30x1338

230V / 415V

28 / 11

32 / 16

50

30

15.88 (5/8)

9.52 (3/8)

2 core

PUHZ-RP200YKA

1050x330+30x1338

415V

19

20

100

30

28.58 (1 1/8)

9.52 (3/8)

2 core

Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for PHV1000R DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.

Page 65: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

INDOOR UNIT PHV2000 NT

Mr

SlimRange

Dimensions

PH

V N

TSensible Cooling

Chilled Water Heat Pump

Rear View >

Upper View >

Page 121

Side View >

Upper View >

PHV NT Chilled Water Heat PumpSensible Cooling Wall Mounted System

In collaboration with Thermoscreens®, Mitsubishi Electric have developed a sensible cooling wall mounted unitthat can be connected to our air to water heat pumps in cooling mode. These systems offer 100% sensiblecooling (SHF of 1) for use in server rooms and other sensible cooling applications.

� SHF of 1 and capacity validated by 3rd party assessment (BSRIA)

� Reduced CO2 emissions

� Reduced Running Costs

� Inverter technology (does not waste energy)

� Easy to install and maintain

� Ideal for small to medium size server rooms / laboratories

� No 3rd party humidifier is required

� PAR-W21MAA controller included

� Pump not included

Page 120

Technical Information

PHV NT - INDOOR UNITS

MODEL REFERENCE

DIMENSIONS (mm) Width

Depth

Height

CAPACITy (kW) Cooling

SHF

EER

ELECTRICAL SUPPLy

PHASE

LOADING (A)

VELOCITy (m/s)

AIR VOLUME (m3/h)

WEIGHT (kg)

NOISE (dBA) @ 3m

WATER VOLUME FLOW RATE (m3/h)

HyDRAULIC RESISTANCE (kPa @ 3.18 m3/h)

WATER VOLUME OF COIL (litres)

PUHZ-HW140YHA2

53

148

1020

330 + 30

1350

380-415v, 50Hz

3

100

15

2.5

7.6 [13]

16

5

4.3

-5ºC ~ +46ºC

PHV2000 NT

2296

377

255

12.0

1.0

3.8

220-240v, 50Hz

Single

2.7

9

2885

90

59

3.18

36

5.1

PUHZ-HW140VHA2

53

134

1020

330 + 30

1350

220-240v, 50Hz

Single

100

15

2.5

22.2 [35]

40

3

4.3

-5ºC ~ +46ºC

PUHZ-HW - OUTDOOR UNITS

MODEL REFERENCE

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLy

PHASE

AIRFLOW (m3/min)

HyDRAULIC RESISTANCE (kPa @ 3.18 m3/h)

WATER VOLUME IN HEAT EXCHANGER (litres)

RUNNING CURRENT (A) [MAX]

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. CORES

CHARGE R410A (kg)

OPERATING RANGE

Notes:Water flow temperature to be set to 10ºC (cannot be set lower). Includes room/return air temperature control, remote On/Off and room over-heat alarm.Test conditions: 35ºC DB / 27ºC WB outdoor conditions, 24ºC DB / 40% relative humidity indoor conditions - validated by BSRIA assessment.

C. 1

50m

in.

for p

ipes

255

295

OUTDOOR UNIT PUHZ-HW140VHA2 / PUHZ-HW140yHA2

Upper View >

Side View >

VH

A

YH

A93

1

1079

23

371

635

1350

3221020

34

7440

Front View >

Installation Feet

Rear Air Intake

Air Discharge

Side Air Intake

2853

370

19

417

210600210

330

30

168

36

Page 66: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Outdoor Heat Pump

PUHZ-RP71

PUHZ-HRP71

PUHZ-P100

PUHZ-RP100

PUHZ-HRP100

PUHZ-P125

PUHZ-RP125

PUHZ-HRP125

PUHZ-P140

PUHZ-RP140

PUHZ-P140

PUHZ-RP140

PUHZ-P200

PUHZ-P200

PUHZ-P200

PUHZ-RP200

PUHZ-RP200

PUHZ-RP200

PUHZ-P250

PUHZ-P250

PUHZ-P250

PUHZ-RP250

PUHZ-RP250

PUHZ-RP250

Total Heating Capacity (kW)

3.5 - 10.2

4.5 - 10.2

4.5 - 12.5

4.5 - 14.0

4.5 - 14.0

5.0 - 16.0

5.0 - 16.0

5.0 - 16.0

5.0 - 18.0

5.0 - 18.0

5.0 - 18.0

5.0 - 18.0

9.5 - 25.0

9.5 - 25.0

9.5 - 25.0

9.5 - 25.0

9.5 - 25.0

9.5 - 25.0

12.5 - 31.5

12.5 - 31.5

12.5 - 31.5

12.5 - 31.5

12.5 - 31.5

12.5 - 31.5

Total Cooling Capacity (kW)

3.3 - 8.1

4.9 - 8.1

4.9 - 11.2

4.9 - 11.4

4.9 - 11.4

5.5 - 14.0

5.5 - 14.0

5.5 - 14.0

5.5 - 15.0

5.5 - 15.3

5.5 - 15.0

5.5 - 15.3

9.0 - 22.4

9.0 - 22.4

9.0 - 22.4

9.0 - 22.4

9.0 - 22.4

9.0 - 22.4

11.2 - 28.0

11.2 - 28.0

11.2 - 28.0

11.2 - 28.0

11.2 - 28.0

11.2 - 28.0

Pipe Kit Part Number

MSDD-50TR-E

MSDD-50TR-E

MSDD-50TR-E

MSDD-50TR-E

MSDD-50TR-E

MSDD-50TR-E

MSDD-50TR-E

MSDD-50TR-E

MSDD-50TR-E

MSDD-50TR-E

MSDT-111R-E

MSDT-111R-E

MSDD-50WR-E

MSDT-111R-E

MSDF-1111R-E

MSDD-50WR-E

MSDT-111R-E

MSDF-1111R-E

MSDD-50WR-E

MSDT-111R-E

MSDF-1111R-E

MSDD-50WR-E

MSDT-111R-E

MSDF-1111R-E

Multi-Split Systems - Combinations Table

Indoor Unit

Size 35

Size 35

Size 50

Size 50

Size 50

Size 60

Size 60

Size 60

Size 71

Size 71

Size 50

Size 50

Size 100

Size 60

Size 50

Size 100

Size 60

Size 50

Size 125

Size 71

Size 60

Size 125

Size 71

Size 60

No. of Indoor Units

2

2

2

2

2

2

2

2

2

2

3

3

2

3

4

2

3

4

2

3

4

2

3

4

Technical Information

Mul

ti-S

plit S

yste

ms

Mr

SlimRange

Page 123

Inverter Heat Pump

Mr Slim Multi-Split Systems

IndoorUnits

Indoor Units

Outdoor UnitsOutdoor Units

Multi distributorPipes

Multi distributorPipes

BB

C

CD

h h

HH

Indoor Units

OutdoorUnits

Multi distributorPipes

C

DE

B

A

h

H

AA

QUADRUPLETRIPLETWIN

PIPE RUN PARAMETERS

Outdoor Model Pipe Runs Max. Pipe Run (m)

PUHZ-P100-140VHA3/yHA A+B+C twin 50

PUHZ-P200/250yHA3 A+B+C twin 70

PUHZ-RP71VHA4 A+B+C twin 50

PUHZ-RP100-140VKA/yKA A+B+C twin 75

PUHZ-RP200/250yKA A+B+C twin 80 (120)

PUHZ-HRP71-125VHA2/yHA2 A+B+C twin 75

PUHZ-P140VHA3/yHA A+B+C+D triple 50

PUHZ-P200/250yHA3 A+B+C+D triple 70

PUHZ-RP140VKA/yKA A+B+C+D triple 75

PUHZ-RP200/250yKA A+B+C+D triple 80 (120)

PUHZ-P200/250yHA3 A+B+C+D+E quadruple 70

PUHZ-RP200/250yKA A+B+C+D+E quadruple 80 (120)

PUHZ-P100-140VHA3/yHA B – C or C – D or B – D 8

PUHZ-RP71-140VHA4/VKA/yKA B – C or C – D or B – D 8

PUHZ-HRP71-125VHA2/yHA2 B - C 8

PUHZ-P200/250yHA3 B - C or B - D or B - E or C - D or C - E or D - E 8

PUHZ-RP200/250yKA B - C or B - D or B - E or C - D or C - E or D - E 8

H = 30m. h = 1m. Note: H for the PUHZ-RP200/250YKA = 40m

The multi-split system is an ideal option for open plan spaces in medium sized premises such as offices or shops, wheretwo, three or four units are required. These can be Mr Slim ceiling cassettes (PLA-RP & SLZ-KA), ceiling suspended (PCA-RP), ducted (PEAD-RP), floor standing (PSA-RP) or wall mounted (PKA-RP) models and can be connected to asingle outdoor unit using twin, triple or quadruple multi distributor pipes.

� Twin, triple or quadruple indoor heat pump units can be operated inMulti-Split configuration from a single outdoor unit

� Heat pumps must operate in same heating or cooling mode

� Cooling capacity range 3.3 to 28kW

� Heating capacity range 3.5 to 31.5kW

� SLZ-KA indoor units can now be connected as part of a Mr Slim Multi-Split system

Note: SEZ-KD indoor units cannot be used as part of a Mr Slim Multi-Split system. PSA-RP indoor units cannot be connected with indoor units of different type.PCA-RP, PSA-RP and SLZ-KA indoor units cannot be connected to PUHZ-HRP outdoor units.PKA-RP indoor units cannot be connected to PUHZ-HRP71 & PUHZ-HRP125 outdoor units.

Technical Information

Page 122

h

Page 67: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Dimensions

Out

door

Uni

t D

imen

sions

Mr

SlimRange

Page 125

Outdoor Units

SUZ-KA50/60VA2

10

69

800

302.5

500 Bolt pitch for installation

150

22.3

55

0

28

0

16

4.5

99

.5 170.5

23

4335

Side View >

28

5

34

4.5 4

4

400

Air in

Air out

Air in

17

.5

Bo

lt p

itch

fo

rin

sta

llatio

n3

04

~3

25

40

SUZ-KA25/35VA2

Upper View >

Front View >

40

515299

66

3451

33

0

36

0

500

Air in

Air in

Air out

85

04

30

80121

840

3035

15

59

0

198

Upper View >

Front View > Side View >

Dimensions

Page 124

417

C D

E F

(19)

370

2853

175600175

330

Air Discharge

Rear Air Intake

Side Air Intake

Installation Feet

3023

943

473

950

322

447 A

B

F5654

E4541

D4241

C6656

B670589

PUHZ-P100VHA3PUHZ-P100YHA

A443431

Upper View >

Front View >

PUHZ-P100VHA3 / PUHZ-P100YHA

Side View >

SUZ-KA71VA2

Upper View >

Front View > Side View >

Page 68: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Out

door

Uni

t D

imen

sions

Mr

SlimRange

Page 127

DimensionsOutdoor Units

Dimensions

Page 126

PUHZ-RP60/71VHA4

40 54

2837

019

417

5357 41

600 175175

330

Rear air intake

Air discharge

Side air intakeInstallation Feet

29

322

950

473

943

23

447

431

673

Front View >

Upper View >

Side View >

Air intake

Air discharge

Air intake

43.6

152

155

400347.5

45.4

365

330

300

40

32.5

Front View >

Upper View >

600

10

300

150

287.5

Installation bolt pitch: 500800

69

18

35 43

183

90155

23

Side View >

PUHZ-RP35/50VHA4

Air Discharge

Rear Air Intake

Side Air Intake

600175 175

330

417

3761

535640

(19

)28

370

Installation Feet

30

1350

23

950

995

999

439

339 A

371

635

322

PUHZ-P200YHA3PUHZ-P250YHA3

A447421

PUHZ-P200YHA3PUHZ-P250YHA3

A447421

PUHZ-P200/250YHA3

Upper View >

Front View > Side View >

Air Discharge

Rear Air Intake

Side Air Intake

600175 175

330

417

4156

535441

(19

)28

370

Installation Feet

30

1350

23

950

A

447

431

371

635

322

PUHZ-P125/140VHA3PUHZ-P125/140YHA

A1076994

PUHZ-P125/140VHA3 / PUHZ-P125/140YHA

Upper View >

Front View > Side View >

PUHZ-P125/140VHA3PUHZ-P125/140YHA

A1076994

Page 69: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Rear air intake

Air discharge

Side air intake

Installation Feet

2837

0

6030

225225

330

600

417

19

70 42

40

53

56

0

632

450

A

369

362

26

1338

1050

442

Front View >

Upper View >

PUHZ-RP100-140VKA / PUHZ-RP100-140YKA

Side View >

PUHZ-RP100-140VK APUHZ-RP100-140YK A

Model

9191067

A

PUHZ-RP200/250YKA

Rear air intake

Air discharge

Side air intake

Installation Feet

2837

0

6030

225225

330

600

417

19

70 42

40

53

56

0

1050

632

369

26

1338

362

982

986

A B342

Front View >

Upper View >

Side View >

PUHZ-RP200YKAPUHZ-RP250YKA

Model

442-B

424450A

Out

door

Uni

t D

imen

sions

Mr

SlimRange

Page 129

Outdoor Units

Dimensions

Page 128

PUHZ-HRP71/100VHA2 / PUHZ-HRP100/140YHA2

Dimensions

Air discharge

Rear air intake

Side air intake

600175 175

330

417

4266

535645

(19

)28

370

Installation Feet

30

23

A

443

447

635

371

1350

322

950

Front View >

Upper View >

Side View >

HRP.VHA2

HRP.YHA2

1079

A

930

Page 70: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Page 130

Accessories / Optional ExtrasM Series

Wall Mounted Units S70 515 716 - Terminal blockS71 000 028 - CN22 connector

Ceiling Concealed Ducted Units MAC-399IF - Interface for connection to M-NET System SEZ-KD25-71VAQMAC-397IF - Interface for group control and run/fault SEZ-KD25-71VAQ

4-Way Blow Cassette Units PLP-6BA - Grille for PLA-RP35-140BA(2)(3)SLP-2AAW - Grille for SLZ-KA25-50VAQPAC-SH53TM-E - Multi function casement PLA-RP35-140BA(2)(3) for fresh air 100mm knockout or

to hold the high efficiency filter optionPAC-SH59KF-E - High efficiency filter PLA-RP35-140BA(2)(3)PLP-6BALM - Grille and infra-red controller PLA-RP35-140BA(2)(3)PLP-6BAJ - Grille with filter lowering function PLA-RP35-140BA(2)(3)PAC-SA1ME-E - ‘I-See Sensor’ corner panel PLA-RP35-140BA(2)(3)PAR-SA9FA-E - Infra-red signal receiver PLA-RP35-140BA(2)(3)S70E40714 - Infra-red controller (PAR-SL97A-E) PLA-RP35-140BA(2)(3)MAC-399IF - Interface for connection to M-NET System SLZ-KA25-50VAQMAC-397IF - Interface for group control and run/fault SLZ-KA25-50VAQ

Ceiling Suspended Units PAR-SL94B-E - Wireless remote controller and adaptorPAC-SH83DM-E - Optional drain lift pump PCA-RP50KAQPAC-SH85DM-E - Optional drain lift pump PCA-RP60KAQPAC-SH84DM-E - Optional drain lift pump PCA-RP71-140KAQPAC-SG38KF-E - Oil mist filter for PCA-RP71/125HAQ (12 pack)PAC-SF81KC-E - Decoration covers (front cover & suspending bracket) for PCA-RP71HAQPAC-SF82KC-E - Decoration covers (front cover & suspending bracket) for PCA-RP125HAQ

Outdoor Units PAC-SG61DS-E - Drain socket set PUHZ-RP35-250VHA4/VKA/YKA / PUHZ-P100-250VHA3/YHA/YHA3 / PUHZ-HRP71-125VHA2/YHA2

PAC-SG58SG-E - Air outlet guide PUHZ-RP35-50VHA4PAC-SG59SG-E - Air outlet guide PUHZ-RP60-71VHA4 / PUHZ-P100VHA3/YHA /

PUHZ-P125-250VHA3/YHA/YHA3 (2 sets required) / PUHZ-HRP71-125VHA2/YHA2 (2 sets required)PAC-SH96SG-E - Air outlet guide PUHZ-RP100-250VKA/YKA (2 sets required)PAC-SG56AG-E - Air protect guide (allows cooling at -15ºC) PUHZ-RP35-50VHA4PAC-SH63AG-E - Air protect guide (allows cooling at -15ºC) PUHZ-RP60-71VHA4 / PUHZ-P100VHA3/YHA /

PUHZ-P125-250VHA3/YHA/YHA3 (2 sets required) / PUHZ-HRP71-125VHA2/YHA2 (2 sets required)PAC-SH95AG-E - Air protect guide (allows cooling at -15ºC) PUHZ-RP100-250VKA/YKA (2 sets required)

System Control Units PAC-SA89TA-E - Remote on/off adaptorPAC-SF40RM-E - Run/fault indicationPAC-SE41TS-E - Remote sensorPAC-SF81MA - A/M-NET adaptorPAC-YT51CRB - Simplified remote controllerPAR-30MAA - Wired controllerPAC-SK82SI-E - Sub interface board

Pipe Kits MSDD-50TR-E - Multi distribution pipe twin units - 50:50 - sizes 71/100/125/140MSDD-50WR-E - Multi distribution pipe twin units - 50:50 - sizes 200/250MSDT-111R-E - Multi distribution pipe triple units - 33:33:33 - sizes 140/200/250MSDF-1111R-E - Multi distribution pipe quadruple units - 25:25:25:25 - sizes 200/250

Power Supply Terminal Kits PAC-SH52HR-E - Power supply terminal kit for PLA-RP when using PUHZ-RP200/250YKAPAC-SG94HR-E - Power supply terminal kit for PKA-RP when using PUHZ-RP200/250YKAPAC-SG96HR-E - Power supply terminal kit for PCA-RP / PSA-RP when using PUHZ-RP200/250YKAPAC-SG97HR-E - Power supply terminal kit for PEAD-RP / PCA-RP-HAQ when using PUHZ-RP200/250YKA

Air

Han

dlin

g U

nit

Cont

rolle

r /

Acc

esso

ries

/ O

ptio

nal Ex

tras

Mr

SlimRange

Page 131

Air Handling Unit Controller

PAC-IF012B-E

PAC-IF012B-EMITSUBISHI ELECTRIC OUTDOOR UNIT

CAPACITy (kW) Heating (nominal)

Cooling (nominal)

AUTO STEP PUHZ-RP

PUHZ-P

SUZ-KA

PUHZ-HRP

MANUAL STEP PUHZ-RP

PUHZ-HRP

PIPE SIZE (mm) PUHZ-(H)(R)P

Gas / Liquid SUZ-KA

HEAT EXCHANGER Max Capacity

Min Capacity

DIMENSIONS (mm) Width

Depth

Height

WEIGHT (kg)

SIZE 35

4.1

3.6

VHA4

-

VA2

VHA4

12.7 / 6.35

9.52 / 6.35

1050

350

336

69

278

2.5

SIZE 50

6.0

5.0

VHA4

-

VA2

VHA4

12.7 / 6.35

12.7 / 6.35

1500

500

336

69

278

2.5

SIZE 60

7.0

6.0

VHA4

-

VA2

VHA4

15.88 / 9.52

15.88 / 6.35

1800

600

336

69

278

2.5

SIZE 71

8.0

7.1

VHA4

-

VA2

VHA2

VHA4

VHA2

15.88 / 9.52

15.88 / 9.52

2130

710

336

69

278

2.5

SIZE 100

11.2

10.0

VKA/yKA

VHA3/yHA

-

VHA2/yHA2

VKA/yKA

VHA2/yHA2

15.88 / 9.52

-

3000

1000

336

69

278

2.5

SIZE 125

14.0

12.5

VKA/yKA

VHA3/yHA

-

yHA2

VKA/yKA

yHA2

15.88 / 9.52

-

3750

1250

336

69

278

2.5

SIZE 140

16.0

14.0

VKA/yKA

VHA3/yHA

-

VKA/yKA

15.88 / 9.52

-

4200

1400

336

69

278

2.5

SIZE 200

22.4

19.0

yKA

yHA3

-

yKA

28.58 / 9.52

-

6000

2000

336

69

278

2.5

SIZE 250

27.0

22.0

yKA

yHA3

-

yKA

28.58 / 12.7

-

7500

2500

336

69

278

2.5

The Air Handling Unit Controllers are an interface to allow connection to third party manufacturerequipment.

Mitsubishi Electric Mr Slim outdoor units can be used with this interface box, creating an ideal solution when a unique air handling unit is required.

� No need for expansion device

� Error, operation and defrost output

� Demand control by analogue or digital inputs

(0-10Ω, 4-20mA , 1-5V, 0-10V, Step, Auto-Step)

� Now includes a third thermistor to enable Auto-Step

Note: One air handling unit controller is required per air handling unitCooling: Indoor 27ºC DB/19ºC WB, Outdoor 35ºC DB/24ºC WBHeating: Indoor 20ºC DB, Outdoor 7ºC DB/6ºC WB

A Control wiring Thermistor wiring

Piping

Air Handling Unit (field supplied)

Controller (field supplied)

Outdoor Unit (Mitsubishi Electric)

Air Handling Unit Controller (Mitsubishi Electric)

Example:

Technical Information

VOLUME (cm3)

Page 71: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

City Mult i Energy EfficientVRF Systems

Air Conditioning Commercial Heating

Domestic Heating Photovoltaics

Page 72: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

The City Multi Range:Solutions for More Demanding Applications

Page 135

Eff icient and FlexibleThe City Multi range is Mitsubishi Electric’s answer to large scale VRF (Variable Refrigerant Flow) applications. The efficiencyof City Multi is second to none and offers a substantial increase in energy efficiency, with corresponding EER/COP ratings.

The City Multi Y Series range offers a simple and flexible solution where there is a demand for a changeover capability between heating and cooling, helping to ensure a constant, comfortable indoor climate.

Mitsubishi Electric also has the ability to provide simultaneous heating and cooling through its R2 and WR2 systems. This is achievedthrough only two pipes rather than the conventional three. Further developments with the City Multi range now enable heat to bemoved to areas of a building that can best make use of it, these include air curtains and the generation of hot water. By moving heatin this way the system becomes central to providing a wider range of environmental services and further increases the run cost andCO2 emission reductions you would normally expect, as well as generating the hot water from this renewable heat source. By usingMitsubishi Electric’s 2-pipe heat recovery technology, substantial savings can again be made on annual running costs. With a range of over 80 indoor units, up to 50 (depending on the capacity available) can be connected to a YJM-A outdoor unit.

Broadening the range of potential City Multi applications is Mitsubishi Electric’s 4th generation water cooled R410A WR2 system. This system not only produces heat recovery from the refrigerant circuit but also via its water circuit, offering double heat recovery potential.

Sophisticated technology, combined with a high level of control and energy efficiency:City Multi is perfectly positioned to meet the demands of today’s market.

Page 134

The strength of

City MultiThe R410A YJM-A seriesoffers some of the highest

EER/COP ratings in the market.

Page 73: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Page 136

The Basics:

Our Answer to VRFMitsubishi Electric sets the boundaries of VRF technology with the City Multi range, which is available using R410Arefrigerant. The range has been specifically designed for today'sbuilding requirements and addresses key market issues such asenergy efficiency, adaptability and reliability. Mitsubishi Electricmanufactures the only 2-pipe heat recovery simultaneousheating and cooling system in the world and equally unique,a water-cooled version. With user fr iendly control systemsutilising internet technology and integrated cooling andventilation indoor units, City Multi is the benchmark and market leader in VRF technology.

What is InverterDriven Technology?Mitsubishi Electric spends more than 5% of its turnover onresearch and development, with our engineers always looking at ways in which we can improve and lead in air conditioningefficiency. The use of inverter technology in our City Multisystems is paramount in this process, working by varying thecompressor speed to match the cooling or heating load, therebyconsuming only the power necessary to match the exactrequirement of the room. When City Multi is operating atpartial load, the energy efficiency of the system is significantlyhigher than at full load. In a typical application partial loadconditions prevail for more than 90% of operation time.A fixed speed system can only operate at 100% capacity andcannot match the annual efficiencies of an inverter system

What is a Heat Pump System?Mitsubishi Electric’s City Multi Y and WY Series’ are heat pumpsystems, which provide either heating or cooling to a building atany given time.

What is a HeatRecovery System?Mitsubishi Electric’s City Multi R2 and WR2 Series’ have theability to provide heating and cooling at the same time in areasconnected to the same outdoor unit.

Page 137

What is VRF?VRF stands for Variable Refrigerant Flow. A VRF airconditioning system modulates the flow of refrigerantdepending upon the capacity requirements of the building.

A VRF system comprises of a condensing unit sitedexternally and a series of multiple indoor units to provide cooling and/or heating to the occupied space.

Why R410A?R410A is a more efficient refrigerant as it has a higher specificheat capacity when compared to R407c or R22. This higherenergy carrying capacity allows for smaller pipe sizes, longerpipe runs and reduces the volume of refrigerant within a system.

This is a major factor when complying with EN378, a Europeanstandard concerning safety and environmental requirements in the design, manufacture, installation, operation, maintenance and disposal of refrigerating systems.

Why Heat Recovery?Flexibility and efficiency are key factors when selecting a heatrecovery system. For example, while a heat pump system isadequate for a large open plan office, businesses that have amore partitioned structure to an office will require the needto simultaneously heat or cool different sections of the officeaccording to each users individual preferences.

The efficiency of this type of system comes from the ability touse the by-products of cooling and heating to transfer energywhere it is required, thus acting as a balanced heat exchangerachieving up to 20% cost savings over a conventional heatpump system. The number of connection sites needed for a R2 / WR2 system are also significantly lower thanthose needed for a three pipe version. This helps to reduce installation costs, further increasing the savingsassociated with City Multi.

How Does the R2 / WR2Heat Recovery SystemOperate on 2 Pipe’s?

The secret of City Multi heat recoverysystems lies in the BC Controller

The BC Controller houses a liquid/gas separator, allowing the outdoor unit to deliver a mixture (2 phase) of hot gas forheating and liquid for cooling, all through the same pipe. Threepipe systems allocate a pipe to each of these phases. Whenthis mixture arrives at the BC Controller, it is separated andthe correct phase delivered to each indoor unit depending onthe individual requirement of either heating or cooling.

Comparison Example of Piping Connection Sites

Page 74: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Heat Interchange CircuitTo further enhance the class leading efficiency of City Multi, theunique Heat Interchange Circuit provides extra sub cooling.This system allows optimum refrigerant distribution to multipleindoor units, by allowing more effective use of refrigerantflowing through the electronic expansion valves.

Because of the added efficiency, volumes of refrigerant in systemsare continuing to reduce.

The Difference Between YJM-A and PreviousMitsubishi Electric ModelsTechnology is key when increased efficiency isdemanded. The City Multi YJM-A range isdesigned to deliver this.

A highly efficient R410A scroll compressor design results inless friction losses at the motor. A simplified refrigerant circuit(low pressure loss) including new accumulator design also addsa few more points to the efficiency scale.

Enhancements to the heat interchange circuit, inverter drivenfan motor and heat exchanger design, again add vital increasesto overall system efficiency and COPs.

Total Energy Conservation

Comparison of COP (energy efficiency) of an 8hp YJM-A system.

31% 36%4.134.46

CITY MULTI REFRIGERANT

CIRCUIT

NORMAL REFRIGERANT

CIRCUIT

The Technology to MakeCity Multi the Natural Choice

City Multi Systems: 8-18hp

City Multi Systems: 20-36hp

City Multi Systems: 38-50hp

Page 138

City Multi R410A YJM-A TechnologyUsing the very latest in IPM (Intelligent Power Module)technology, precise control of energy input is achievedallowing City Multi to fur ther improve COPs for R410Asystems. IPM uses 1Hz steps of capacity control, matchingbuilding requirements through more accurate control of theoccupied space with reduced power input.

As in previous versions, IPM technology operates extremelyeffectively under part load conditions (50-80% of operatingcapacity), a condition that most systems will be in for theirnormal working life. Therefore the consideration of efficiency at part load is accounted for as well as when at peak loadconditions, offering high system efficiency all year round.

Stable and Smooth Operation:100% Inverter ControlAll City Multi compressors are inverter-driven andcapable of precisely matching a building's coolingand heating demands.

The outdoor unit combinations comprise of one module for 8-18hp systems, two modules for 20-36hp systems and threemodules for 38-50hp systems (Y series only). Each modulecarries one inverter compressor making simple and highly reliablecontrol possible. Not only does it allow low starting currents, the inverter driven compressor also provides precise indoorcomfort and adapts to the air conditioning load, achieving smooth transition across the range of compressor frequencies

Energy efficiency has always been the driver for City Multi technological development that always delivers the quality and reliability needed for commercial air conditioning environments.Mitsubishi Electric spend more than 5% of their turnover on research and development, with ourengineers always looking at ways in which we can improve and lead in air conditioning efficiency.

Page 139

The Importance of COPCOP stands for “Co-efficient of Performance”. It is ameasure of the useful energy a system can deliver comparedto the energy that it consumes. It is calculated by dividing theenergy output by the energy input of a system. The higher the figure then the more efficient the system is deemed to be,with commensurate reduced running costs.

For Heat Pumps to be included on the Energy TechnologyProduct List under the Enhanced Capital Allowance scheme,they must fall within the criteria specified by the ECA. Forfurther information on qualification please visit www.eca.gov.uk

Total Energy Conservation

Page 75: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Ground SourceHeat Pumps

J

City MultiZubadanAir Source Heat Pumps

The City Multi Zubadan heat pumps achieve an excellent heating performance even when theoutdoor air temperature is as low as -25°C.

These models make use of a Flash Injection Circuit, which allows the optimal amount of refrigerant to be provided to the system viathe compressor through a specially designed injection port. In simple terms, the system allows a quick start up time and continuousheating; even in low ambient conditions.

Full heatingcapacity evenat -15°C

Capacityimprovementof 30%

Outdoor temp.°C (W.B.)

PUHY-HP250 YHM-A

Standard CITY MULTI

PUHY-P400 YSJM-A

Standard CITY MULTI

PUHY-P250 YJM-A

50.0

25.0

(kW)

10.0 -25 -20 -15 -10 -5 0 3

PUHY-HP400 YSHM-A

J

Ground Source Heat Pump installed insidethe building, typically one per floor

Bore holes absorb or reject heat from the ground

Flow and return water loop supplies water to and from the units

Indoor units provide heating or cooling

Example of a Closed Loop Bore Hole Application:

Smaller YHM-A models now available, in a wider variety

of sizes

Page 140

There are two standard ground source methods available, Open Loop and Closed Loop (Bore Hole or Slinky):

� Open Loop - Large bodies of water can be utilised as a stable source of water at a relatively constant temperature. This can be either surface water or ground water. Surface water would include lakes, reservoirs, rivers and the sea.

� Closed Loop Slinky - A trench is dug to a depth of between 1.7 to 3m and plastic spiral pipe is laid into the bottom. The pipe is covered with sand to provide good ground to pipe contact and then the trench is backfilled with theexcavated soil.

� Closed Loop Bore Hole - A series of holes are drilled down into the ground at a depth of 50 to 130m, dependingon geothermal conditions. Two water pipes connected via a 'u bend' are fed directly into these holes and then surroundedby a conductive grout.

A very efficient source of energy for water source heat pumpsystems is the Earth itself. Ground source heat pumps use the Earth's naturalsolar collection and heat storage capabilities as an infinite heat source/heat sink.At between 1.7m and 3m below the ground, the temperature changes from 17ºC in the summer to 10ºC in the winter. Deeper downhowever, the temperature of the ground is a constant 10ºC all year round. It is these relatively constant, dependable temperatures thatcan be harnessed using ground source heat pumps. The constant ground temperatures allow the heat pump to operate at optimumefficiency in both heating and cooling, as the high summer or low winter temperatures do not influence performance. Heat is extractedor rejected into the ground using water which is pumped through a network of plastic pipes.

Page 141

Expanded Heating OperationWill work effectively even when the outdoor ambient airtemperature is -25°C.

Stable Heating PerformanceFull heating capacity at -15°C, a 30% capacity improvementover the standard YJM-A model.

Stable OperationUtilising the new Flash Injection Circuit the Zubadan modelshave reduced defrost times and can provide continuousheating for up to 250 mins.

Quick Start-UpFull heating capacity is achieved in about 20 mins, improving comfort levels.

Page 76: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Refrigerant Volume Checking FunctionThis function runs the system, measuring various temperatures and pressures throughout thesystem, comparing these to the values stored in the units memory from the previous service. If a leakage has occurred the system will indicate so, enabling customers to easily comply with the F-Gas regulation.

Replace TechnologyThe latest VRF Replace Multi models from Mitsubishi Electric are specifically designed for thematuring refurbishment sector, enabling the reuse of existing R22 / R407c pipework, whilstalso allowing the upgrade to some of the most efficient systems available in the market.

Replace Multi will clean the existing pipework during commissioning, removing any depositsand R22 mineral oil that would have ordinarily meant that new pipework would have beencalled for. The implications of this are significant savings on cost and time, whilst alsominimising any potential disruption.

Cooling Operation Set Temperature of 14ºCEnvironments such as gyms, laboratories etc often require the ability to cool lower than the standard comfort cooling setpoint. By selecting a dip switch on the unit, a cooling operation set temperature of 14ºC DB is possible on the floor standing and ducted models only. The indoor unit fan will be fixed at high speed during this operation.

New fan designReduction of operation noise

New control box designImprovement of reliability and easy maintenance

Features and BenefitsHigh Off Coil / High Sensible CoolingPoor design or application of air conditioning systems can sometimes lead to cold draughts and uneven room temperatures. Low off coil temperatures cause dehumidifying of the air which can create dry eyes and sore throats.

Mitsubishi Electric now provides a High Sensible Cooling Function specifically designed to deal with this. By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants. Thesehigh SHF’s are available throughout the range of indoor units, allowing optimum selection of units tailored to more specific design criteria.

Page 142

Reduced Noise Levels:New Fan Design

City Multi VRF systems led the introduction of larger single fan rotors some ten years ago, achieving substantially lower noise levels over multiple designs.Continuing the development in the areas of blade shape and weight, MitsubishiElectric have managed to achieve even higher performance and lower noise levels.

To reduce noise levels further and comply with inner city residential noiseregulations, all outdoor units include Night Set-back mode. This function works bylowering the fan speed and compressor frequency proportionally with reduction in demand (44dBA for PUHY-P250YJM-A). The compressor compartment is also now sealed, further reducing noise levels.

Page 143

Fine Control of theInverter ProvidesBetter Eff iciencyand PerformanceAir cooled inverters use the ambienttemperature to cool the inverter. Forwater cooled VRF (which are installedinside the building) refrigerant cooling is used to maintain accurate control of the Inverter.

New heat exchanger designA cross-steer fin structure with additionalslits helps to improve COP by up to 2% incooling. The heating COP is also improvedby 1% with the introduction of a 2.5 rowheat exchanger, improving airflow andtemperature valance.

New inverter compressorImprovement of COP and partial loadperformance thanks to the new concentrated winding structure.

Previous YHM-A

NewYJM-A

Slits

Fin Structure

Heat Exchanger

YHM-A: 3 rows YJM-A: 2.5 rows

Page 77: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Effective Use of SpaceYJM-A models have a smallerfoot print requirement when compared to the YGM-A models.The width and depth have beenreduced by 7% and 13% respectively, with the height being reduced by 130mm (PUHY-P250YJM-A compared to PUHY-P250YGM-A).

Blue Fin TreatmentThe anti-corrosion Blue Fin treatment of the heat exchanger is especiallyeffective in urban environments where traffic pollutions can damagethe aluminium fins, reducing the capacity and life expectancy of the unit.

All City Multi R410Aoutdoor units have been treated with Blue Fin

YJM-A

YGM-A YJM-A

YGM-A

33kg

Approximately 21% reduction in foot print (PUHY-P250)

Hei

ght

1710

mm

Width920mm

Depth760mm

8-12hp outdoor units

Example of lift

Weight ReductionWeight has been reduced by approximately 33kg per module.

(PUHY-P250YJM-A compared to previous YGM-A versions).

Page 144 Page 145

Easily TransportedThe unit can easily be transported, even into inaccessible buildings. Narrow space between buildings often makes it difficult to use acrane, City Multi helps to overcome this due to its design.

The downsized outdoor unitcan also be transported through an 800mm wide lift door, making access to rooftops easier.

The designof City Multi

outdoor units makesinstallation

easy

Page 78: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

R410A Pipe SizingAs R410A has a higher specific heat capacity than R22, the pipework is smaller.

This means the pipe itself is cheaper, easierto install and less riser space is requiredwithin the building.

Example of a 10hp model

Heating Operation Range:Standard & High COP air cooled unitsAt low ambient temperatures the guaranteed operating

range in heating is minus 20ºCOperating range in cooling is from an outdoor temperature of -5ºC.

Back-Up & RotateBack-up - In the case of one module breakingdown, the remaining units will perform back-upoperation until the faulty unit is repaired.

Rotation - In the case of two or three modules,the load will be balanced between the units overtime, extending the life of the system.

Page 146

Outdoor Temperature (ºC)

Page 147

High Performance HeatingThe new High Performance Heating mode isavailable on all YJM-A / YJM-B models andachieves an excellent heating performance atlow outdoor air temperatures, making it idealfor the UK climate.

Activated by dip switch on the outdoor unit, COP priorityor high performance heating modes can be selected. Highperformance heating mode is pre-selected on all YJM-Aoutdoor models.

In high performance heating mode, the control strategy is alteredto allow the compressor to maintain a higher frequency atlower ambient temperatures, resulting in full nominal capacitydown to -5°C on many models. What this means is that asmaller outdoor unit can be installed to produce the samecapacity as a larger one would if it was in COP priority mode,therefore saving on both cost and space.

In COP priority mode, control is reverted back to normal and the power consumption lowered. However, even at -5°Cthe COP is kept high.

Note: This is only a representation. Actual data varies depending on individual outdoor unit.

-20 -15 -10 -5 0 5 10 15

1.1

1.0

0.9

0.8

0.7

0.6

0.5

0.4

Ambient Temperature

Rat

io o

f Hea

ting

Cap

acity

11% capacity increase

High Performance Heating Mode

COP Priority Mode

Outdoor Temperature (ºC)

Hea

ting

Cap

acity

req

uire

d (k

W)

5.00

4.50

4.00

3.50

3.00

2.50

2.00

6.00

5.50

121086420-2-47.5

12.5

17.5

22.5

27.5

32.5

37.5

CO

P

Heating Capacity Requirement (kW) COP (P250 High Performance Heating Mode)

Note: This is only a representation of a PUHY-RP250 over the winter period. Actual data varies depending on individual outdoor unit.

Seasonal Efficiency The ideal application for high performance heating mode iswith a heating only system, or a system sized for a heating loadas this is where substantial savings can be achieved. A system isdesigned for full load at a fixed design temperature, forexample -3°C WB as in the example below.

In this example, as the ambient temperature rises, the heatingload decreases and the inverter is able to ramp the heat pumpdown, thus increasing efficiency.

Page 79: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

� Under the scheme, all businesses liable for UK corporation tax are able to claim an enhanced capital allowance on any qualifying expenditure (regardless of size and location of business or whether in the industrial orcommercial sector).

� Businesses can offset the full cost of specific technologies (such as City Multi)against taxable profits of the period of the investment.

� In order to qualify for this scheme, technology has to meet the energy saving criteria as published in theEnergy Technology Criteria List. City Multi fully meets this criteria in its drive for energy efficiency.

� Only investment in new and unused plant and machinery qualify.

For further information go to www.eca.gov.uk and click on Mitsubishi Electric Air Conditioning under the heat pump category.

The Key Features of the Scheme:

Mitsubishi Electric produces a series of comprehensive CPD approved IndustryInformation Guides, designed to enhancethe knowledge of our customers and providea view of all the key issues facing our

industry today.

All our information guides are availableto download from our website:

www.mitsubishielectric.co.uk/aircon

City Multi ExceedsCurrent Demands for Eff iciencyThe need for energy efficiency is paramount and is determined by legislation and regulation.In 2009 the Climate Change Act was updated, putting a greater emphasis on reducing energyuse and thus CO2 emissions.

2010 also saw big changes with the introduction of the CRC Energy Efficiency Scheme (formerly the Carbon Reduction Commitment),which is a mandatory emissions trading scheme. It is central to the UK’s strategy for improving energy efficiency and reducing CO2

emissions. The scheme will affect around 5000 organisations, creating a financial incentive to actively reduce their CO2 emissionsacross their business as a whole.

In addition to these, the newly revised Part L of the building regulations outlines the need to reduce carbon emissions by 25% onaggregate over a Part L 2006 building. These regulations show the positive steps being taken towards achieving highly energy efficient,zero carbon new buildings. Mitsubishi Electric’s range of energy efficient heating, cooling, ventilation and controls products all help tocomply with these regulations and schemes.

To encourage efficient use of energy, the UK Government introduced the Enhanced Capital Allowance Scheme (ECA). Qualifyingproducts on the Energy Technology Product List include heat pumps for space heating. The City Multi range has been designed toensure businesses qualify for ECA and benefit from the utmost efficiency, both financially and environmentally.

Page 148 Page 149

Enhanced

Capital Allowance

Scheme

(ECA)

Page 80: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

n nnnn n n n n n n n n n n

n n n n n n n n n n n

A Wide Choice of Models

The model line up

The YJM-A air sourced outdoor models are modular in design and as such differing combinations of themcan be connected together to create the required outdoor unit size needed for a particular application.The new YJM-A models also now make use of an extra large single module.

Both the Y and R2 Series come in Standard (-P) and High COP (-EP) versions. In addition, the standard versions allowfor space-saving by virtue of the combination of units having a smaller foot print than the high COP versions.

Series

Y

Size

Model Name

PUHY-P

PUHY-EP

200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250

8hp 10hp 12hp 14hp 16hp 18hp 20hp 22hp 24hp 26hp 28hp 30hp 32hp 34hp 36hp 38hp 40hp 42hp 44hp 46hp 48hp 50hp

nn n n n n n n n n n n n n n n n n n n n n

n n n n n n n n n n n n n n

R2 PURY-P

PURY-EP

Y Series (10hp) PUHY-EP YJM-A

10hp PUHY-EP250 YJM-A

Y Series (12hp) PUHY-EP YJM-A

12hp PUHY-EP300 YJM-A

Y Series (16hp) PUHY-EP YSJM-A

16hp PUHY-EP400 YSJM-A

Y Series (18hp) PUHY-EP YSJM-A

18hp PUHY-EP450 YSJM-A

Y Series (20hp) PUHY-EP YSJM-A

20hp PUHY-EP500 YSJM-A

Y Series (22hp) PUHY-EP YSJM-A

22hp PUHY-EP550 YSJM-A

R2 Series (8-12hp) PURY-P YJM-A

8hp PURY-P200 YJM-A

10hp PURY-P250 YJM-A

12hp PURY-P300 YJM-A

R2 Series (14-16hp) PURY-P YJM-A

14hp PURY-P350 YJM-A

16hp PURY-P400 YJM-A

R2 Series (18hp) PURY-P YJM-A

18hp PURY-P450 YJM-A

R2 Series (18-24hp) PURY-P YSJM-A(1)

18hp PURY-P450 YSJM-A120hp PURY-P500 YSJM-A22hp PURY-P550 YSJM-A24hp PURY-P600 YSJM-A

R2 Series (8hp) PURY-EP YJM-A

8hp PURY-EP200 YJM-A

R2 Series (10-12hp) PURY-EP YJM-A

10hp PURY-EP250 YJM-A

12hp PURY-EP300YJM-A

R2 Series (14hp) PURY-EP YJM-A

14hp PURY-EP350 YJM-A

R2 Series (16hp) PURY-EP YSJM-A

16hp PURY-EP400 YSJM-A

Y Series (26hp) PUHY-EP YSJM-A

26hp PUHY-EP650 YSJM-A

Y Series (28hp) PUHY-EP YSJM-A

28hp PUHY-EP700 YSJM-A

Y Series (30hp) PUHY-EP YSJM-A

30hp PUHY-EP750 YSJM-A

Y Series (32hp) PUHY-EP YSJM-A

32hp PUHY-EP800 YSJM-A

Y Series (34hp) PUHY-EP YSJM-A

34hp PUHY-EP850 YSJM-A

Y Series (36hp) PUHY-EP YSJM-A

36hp PUHY-EP900 YSJM-A

R2 Series (26-28hp) PURY-P YSJM-A

26hp PURY-P650 YSJM-A

28hp PURY-P700YSJM-A

R2 Series (30-32hp) PURY-P YSJM-A

30hp PURY-P750 YSJM-A

32hp PURY-P800YSJM-A

R2 Series (34hp) PURY-P YSJM-A

34hp PURY-P850 YSJM-A

R2 Series (36hp) PURY-P YSJM-A

36hp PURY-P900 YSJM-A

R2 Series (18-20hp) PURY-EPYSJM-A

18hp PURY-EP450YSJM-A

20hp PURY-EP500YSJM-A

R2 Series (22-24hp) PURY-EP YSJM-A

22hp PURY-EP550YSJM-A

24hp PURY-EP600YSJM-A

R2 Series (26hp) PURY-EP YSJM-A

26hp PURY-EP650YSJM-A

R2 Series (28hp) PURY-EP YSJM-A

28hp PURY-EP700YSJM-A

Y Series (8-12hp) PUHY-P YJM-A

Y Series (14-16hp) PUHY-P YJM-A

14hp PUHY-P350 YJM-A

16hp PUHY-P400 YJM-A

Y Series (18hp) PUHY-P YJM-A

18hp PUHY-P450 YJM-A

Y Series (20-22hp) PUHY-P YSJM-A

20hp PUHY-P500 YSJM-A

22hp PUHY-P550 YSJM-A

Y Series (24-26hp) PUHY-P YSJM-A

24hp PUHY-P600 YSJM-A

26hp PUHY-P650 YSJM-A

Y Series (28-30hp) PUHY-P YSJM-A

28hp PUHY-P700 YSJM-A

30hp PUHY-P750 YSJM-A

Y Series (32-34hp) PUHY-P YSJM-A

32hp PUHY-P800 YSJM-A

34hp PUHY-P850 YSJM-A

Y Series (8hp) PUHY-EP YJM-A

8hp PUHY-EP200 YJM-A

Y Series (36hp) PUHY-P YSJM-A

36hp PUHY-P900 YSJM-A

Y Series (38-40hp) PUHY-P YSJM-A

38hp PUHY-P950 YSJM-A

40hp PUHY-P1000 YSJM-A

Y Series (42hp) PUHY-P YSJM-A

42hp PUHY-P1050 YSJM-A

Y Series (44hp) PUHY-P YSJM-A

44hp PUHY-P1100 YSJM-A

Y Series (46-48hp) PUHY-P YSJM-A

46hp PUHY-P1150 YSJM-A

48hp PUHY-P1200 YSJM-A

Y Series (50hp) PUHY-P YSJM-A

50hp PUHY-P1250 YSJM-A

Y Series (24hp) PUHY-EP YSJM-A

24hp PUHY-EP600 YSJM-A

Y Series Heat Pump - Standard Version

Y Series Heat Pump - High COP Version

R2 Series Heat Recovery - Standard Version

R2 Series Heat Recovery - High COP Version

8hp PUHY-P200 YJM-A

10hp PUHY-P250 YJM-A

12hp PUHY-P300 YJM-A

Page 150 Page 151

Page 81: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Y Series (4/5/6hp)

PUMY-P100-140V/YHMB

63(7.1kW)

80(9.0kW)

100(11.2kW)

125(14.0kW)

140(16.0kW)

200(22.4kW)

140kW Cooling Capacity

Y / R2 Series

PURY-RP200-300YJM-B

Page 153

Y / R2 Series

PUH/RY-P200-300YJM-APUH/RY-EP200YJM-A

11.2kW Cooling Capacity

Model / Size

PLFY-P-VBM-E

PLFY-P-VCM-E2

PLFY-P-VLMD-E

PMFY-P-VBM-E

PEFY-P-VMS1-E

PEFY-P-VMA-E

PEFY-P-VMH-E

PCFY-P-VKM-E

PKFY-P-VBM/VHM/VKM-E

PFFY-P-VLRM-E

PFFY-P-VLRMM-E

PFFY-P-VLEM-E

PFFY-P-VKM-E

GUF-RD3

PWFY-P

15(1.7kW)

20(2.2kW)

25(2.8kW)

32(3.6kW)

40(4.5kW)

50(5.6kW)

Page 152

Indoor Units

250(28.0kW)

City Multi Product Range OverviewOutdoor Units

Y Series Zubadan

PQ(H/R)Y-P200-300YHM-A

WY / WR2 Series

PUHY-HP200/250YHM-APUH/RY-P350/400YJM-A

PUHY-EP250YJM-APURY-EP250/300YJM-A

Y / R2 Series

PUH/RY-P450YJM-APUHY-EP300YJM-APURY-EP350YJM-A

Y Series Replace Multi

PUHY-RP200-350YJM-B

R2 Series Replace Multi

Page 82: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Y Series (4-6hp)Heat Pump, Outdoor Unit

Y Series Standard (8-18hp)Heat Pump, Outdoor Unit

Y Series Standard (20-30hp)Heat Pump, Outdoor Unit

Y Series Standard (32-36hp)Heat Pump, Outdoor Unit

Y Series Standard (38-44hp)Heat Pump, Outdoor Unit

Y Series Standard (46-50hp)Heat Pump, Outdoor Unit

Y Series High COP (8-18hp)Heat Pump, Outdoor Unit

Y Series High COP (20-24hp)Heat Pump, Outdoor Unit

Y Series High COP (26-30hp)Heat Pump, Outdoor Unit

Y Series High COP (32-36hp)Heat Pump, Outdoor Unit

Y Series Zubadan (8-20hp)Heat Pump, Outdoor Unit

Y Series Replace Multi (8-26hp)Heat Pump, Outdoor Unit

Y Series Replace Multi (28-36hp)Heat Pump, Outdoor Unit

WY Series (8-24hp)Heat Pump, Water Cooled Condensing Unit

WY Series (26-36hp)Heat Pump, Water Cooled Condensing Unit

R2 Series Standard (8-18hp)Heat Recovery, Outdoor Unit

R2 Series Standard (18-28hp)Heat Recovery, Outdoor Unit

R2 Series Standard (30-36hp)Heat Recovery, Outdoor Unit

R2 Series High COP (8-20hp)Heat Recovery, Outdoor Unit

R2 Series High COP (22-28hp)Heat Recovery, Outdoor Unit

R2 SeriesPiping Restrictions

R2 Series Replace Multi (8-12hp)Heat Recovery, Outdoor Unit

WR2 Series (8-24hp)Heat Recovery, Water Cooled Condensing Unit

PFD-P-VM-EHeat Pump, Close Control System

PLFY-P-VBM-E2, 3 and 4-Way Blow Ceiling Cassette Indoor Unit

PLFY-P-VCM-E2600x600 4-Way Blow Ceiling Cassette Indoor Unit

PLFY-P-VLMD-E2-Way Blow Ceiling Cassette Indoor Unit

PMFY-P-VBM-E1-Way Blow Ceiling Cassette Indoor Unit

PEFY-P-VMS1-EUltra Thin Ceiling Concealed Ducted Indoor Unit

PEFY-P-VMA-ECeiling Concealed Ducted Indoor Unit

PEFY-P-VMH-EHigh Static Pressure Ceiling Concealed Ducted Indoor Unit

PCFY-P-VKM-ECeiling Suspended Indoor Unit

PKFY-P-VBM/VHM/VKM-EWall Mounted Indoor Unit

PFFY-P-VLRM-EFloor Standing Concealed Indoor Unit

PFFY-P-VLRMM-EFloor Standing Concealed Indoor Unit

PFFY-P-VLEM-EFloor Standing Exposed Indoor Unit

PFFY-P-VKM-EFloor Standing Exposed Indoor Unit

GUF-RD3Lossnay Outdoor Air Processing Unit

PWFY-PVRF Heat Pump Boiler

VRF PHV DXEVRF Heat Pump Air Curtain

VRF PHV NTSensible Cooling, Chilled Water Indoor Unit

BC Controllers

Water System Connection Box (WCB)

Air Handling Unit Controllers

Accessories / Optional Extras

156

158

160

162

164

166

168

170

172

174

176

178

180

182

184

186

188

190

192

194

196

198

200

202

204

206

208

210

212

214

216

218

220

222

224

226

228

230

232

236

238

240

242

243

234

Page 155Page 154

Unique 2-pipe technology provides simultaneous heating and cooling, alongside excellent energy efficiency and corresponding EER/COP ratings.Up to 50 indoor units can be connected to a single outdoor unit, offering thesophistication, control and energyefficiency demanded today.

The energy efficient

City MultiVRF range

Simple technologyat its best

Many of our systems have an energy label of A, are registered onthe Energy Technology List and hence qualify for 100% first yearenhanced capital allowances (whole system cost and ‘reasonable’cost of installation).

Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB.UK Conditions: Winter ; indoor 21˚C DB; outdoor -1˚C WB.

For further information please go to www.eca.gov.uk

Contents

Page 83: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Upper View >

Side View > Front View >

PUMY-P100-140VHMB/YHMB

Cit

y M

ult

iRange

Y S

erie

s (4-6hp)

Dimensions

Page 157

Heat Pump Outdoor Unit

Y Series (4-6hp)

Y SERIES OUTDOOR UNITS 4-6hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

COP / EER (nominal)

Max no. OF CONNECTABLE INDOOR UNITS

Max CONNECTABLE CAPACITY

AIRFLOW (m3/min)

PIPE SIZE mm(in) Gas

Liquid

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

GUARANTEED OPERATING RANGE Cooling

Heating

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

PUMY-P100VHMB

12.5

11.2

10.4

10.3

3.66

3.34

3.27

2.84

3.42 / 3.35

8

50-130% OU Capacity

100

15.88 (5/8”)

9.52 (3/8”)

49

129

950

330+30

1350

220-240v, 50Hz

Single

5

15.5

14.1

-5ºC ~ 46ºC

-15ºC ~ 15ºC

32

3

PUMY-P125VHMB

16.0

14.0

13.3

12.9

4.33

4.32

3.85

3.66

3.69 / 3.24

10

50-130% OU Capacity

100

15.88 (5/8”)

9.52 (3/8”)

50

129

950

330+30

1350

220-240v, 50Hz

Single

5

18.3

18.3

-5ºC ~ 46ºC

-15ºC ~ 15ºC

32

3

PUMY-P140VHMB

18.0

15.5

14.9

14.3

5.58

5.35

4.99

4.53

3.23 / 2.90

12

50-130% OU Capacity

100

15.88 (5/8”)

9.52 (3/8”)

51

129

950

330+30

1350

220-240v, 50Hz

Single

5

23.6

22.7

-5ºC ~ 46ºC

-15ºC ~ 15ºC

32

3

PUMY-P100-140VHMB/YHMB Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

120m max

80m max

30m max

50m max (20m max if outdoor installed below)

12m max

Optional Parts

Model Name Description

CMY-Y62-G-E Branch Pipe (2 Branch)

PUMY-P100YHMB

12.5

11.2

10.4

10.3

3.63

3.30

3.23

2.81

3.44 / 3.39

8

50-130% OU Capacity

100

15.88 (5/8”)

9.52 (3/8”)

49

142

950

330+30

1350

380-415v, 50Hz

3

5

5.32

4.84

-5ºC ~ 46ºC

-15ºC ~ 15ºC

16

4 + earth

PUMY-P125YHMB

16.0

14.0

13.3

12.9

4.29

4.27

3.82

3.63

3.73 / 3.28

10

50-130% OU Capacity

100

15.88 (5/8”)

9.52 (3/8”)

50

142

950

330+30

1350

380-415v, 50Hz

3

5

6.29

6.26

-5ºC ~ 46ºC

-15ºC ~ 15ºC

16

4 + earth

PUMY-P140YHMB

18.0

15.5

14.9

14.3

5.32

5.32

4.73

4.52

3.38 / 2.91

12

50-130% OU Capacity

100

15.88 (5/8”)

9.52 (3/8”)

51

142

950

330+30

1350

380-415v, 50Hz

3

5

7.8

7.8

-5ºC ~ 46ºC

-15ºC ~ 15ºC

16

4 + earth

Technical Information

The latest in Mitsubishi Electric R410A Y Series technology. The new City Multi models allow up to 12 indoor units to be connected to a single outdoor unit, using the standard branch/header pipeworksystem proven in the larger models. Utilising the latest Mitsubishi Electric inverter technology, the system is fully controllable with all City Multi controllers or linked to third party BEMS.

� A two core non-polar transmission line allows for simple installation of up to twelve indoor units now

� Latest in inverter technology including a highly efficient DC Scroll Compressor, DC fan motor and Demand Control

� The condensing unit is extremely slimline which allows easy location and application of the system

� Single or three phase power supply

� Anti-Corrosion blue and flat fin technology

Page 156

Page 84: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PUHY-P200, 250, 300YJM-A

PUHY-P350, 400YJM-A

Upper View >

Cit

y M

ult

iRange

Y S

erie

s St

andar

d (8-18hp)

Dimensions

Front View >Side View >

Page 159

Upper View >Front View >Side View >

Upper View >Front View >Side View >

PUHY-P450YJM-A

Heat Pump Outdoor Unit

Y SERIES STANDARD OUTDOOR UNITS 8-18hp

Y Series Standard (8-18hp)

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PUHY-P200YJM-A

25.0

22.4

25.0

22.8

21.3

5.84

5.62

7.36

5.78

3.23

4.28 / 3.98

17

170

56

190

920

760

1710

380-415v, 50Hz

3

8

9.0

8.6

20

4 + earth

PUHY-P250YJM-A

31.5

28.0

31.5

28.7

26.6

7.34

7.40

9.25

7.27

4.26

4.29 / 3.78

21

170

58

200

920

760

1710

380-415v, 50Hz

3

8

11.3

11.4

20

4 + earth

PUHY-P300YJM-A

37.5

33.5

35.6

32.3

31.5

9.25

9.00

12.40

8.97

5.81

4.05 / 3.72

26

170

59

215

920

760

1710

380-415v, 50Hz

3

8

14.2

13.9

25

4 + earth

PUHY-P350YJM-A

45.0

40.0

42.8

38.7

37.6

11.19

11.01

14.99

10.85

7.10

4.02 / 3.63

30

210

60

250

1220

760

1710

380-415v, 50Hz

3

8

17.2

17.0

32

4 + earth

PUHY-P400YJM-A

50.0

45.0

47.5

43.0

42.3

12.82

13.11

17.18

12.44

8.46

3.90 / 3.43

34

210

61

250

1220

760

1710

380-415v, 50Hz

3

8

19.8

20.2

32

4 + earth

PUHY-P450YJM-A

56.0

50.0

50.7

48.7

46.0

14.62

15.47

16.67

13.30

9.75

3.83 / 3.23

39

370

62

290

1750

760

1710

380-415v, 50Hz

3

8

22.5

23.9

40

4 + earth

PUHY-P200-450YJM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

1000m max

165m max

40m max

50m max (40m max if outdoor installed below)

15m max

Improved for even higher efficiency

Technical Information

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeoverfrom cooling to heating to ensure that a constant indoor climate is maintained.

� Wrap around coil for improved energy efficiency

� Choice of Branch Pipe or Header Pipe feeds to indoor units

� Energy-saving inverter driven outdoor compressor units with very low start currents

� No requirement for plant rooms or bulky service shafts

� Weight and size reduction compared to YGM-A models

� Improved pipe run of 165m, with a total system pipe length of 1000m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

� High Performance Heating Mode for low ambient conditions

Page 158

Page 85: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PUHY-P500, 550YSJM-A

PUHY-P600, 650YSJM-A

Cit

y M

ult

iRange

Y S

erie

s St

andar

d (20-30hp)

Dimensions

Side View > Front View >

Side View > Front View >

Side View > Front View >

PUHY-P700, 750YSJM-A

Page 161

PUHY-P500-750YSJM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

1000m max

165m max

40m max

50m max (40m max if outdoor installed below)

15m max

Heat Pump Outdoor Unit

Y Series Standard (20-30hp)

Improved for even higher efficiency

Technical Information

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

� Wrap around coil for improved energy efficiency

� Choice of Branch Pipe or Header Pipe feeds to indoor units

� Energy-saving inverter driven outdoor compressor units with very low start currents

� No requirement for plant rooms or bulky service shafts

� Weight and size reduction compared to YGM-A models

� Improved pipe run of 165m, with a total system pipe length of 1000m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

� High Performance Heating Mode for low ambient conditions

Page 160

Y SERIES STANDARD OUTDOOR UNITS 20-30hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PUHY-P500YSJM-A

63.0

56.0

57.0

54.8

51.5

15.03

15.38

17.13

13.68

9.69

4.19 / 3.64

43

170 / 170

61

200 + 200

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

23.2

23.7

20 / 20

4 + earth

PUHY-P550YSJM-A

69.0

63.0

62.4

60.0

58.0

16.87

17.16

19.23

15.35

10.81

4.09 / 3.67

47

170 / 170

61.5

215 + 200

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

26.0

26.5

25 / 20

4 + earth

PUHY-P600YSJM-A

76.5

69.0

69.2

66.6

63.5

18.88

18.75

21.52

17.18

11.81

4.05 / 3.68

50

210 / 170

62

250 + 200

1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8

29.1

28.9

32 / 20

4 + earth

PUHY-P650YSJM-A

81.5

73.0

73.8

70.9

67.2

20.47

20.39

23.34

18.63

12.85

3.98 / 3.58

50

210 / 170

62.5

250 + 215

1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8

31.6

31.5

32 / 25

4 + earth

PUHY-P700YSJM-A

88.0

80.0

88.0

76.6

73.6

22.27

22.47

28.06

20.71

14.49

3.95 / 3.56

50

210 / 210

63

250 + 250

1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

34.4

34.7

32 / 32

4 + earth

PUHY-P750YSJM-A

95.0

85.0

95.0

82.7

78.2

24.67

24.70

31.08

22.94

15.93

3.85 / 3.44

50

210 / 210

63.5

250 + 250

1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

38.1

38.1

32 / 32

4 + earth

Page 86: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PUHY-P800, 850YSJM-A

PUHY-P900YSJM-A

Cit

y M

ult

iRange

Y S

erie

s St

andar

d (32-36hp)

Dimensions

Page 163

Side View > Front View >

Side View > Front View >

PUHY-P800-900YSJM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

1000m max

165m max

40m max

50m max (40m max if outdoor installed below)

15m max

Heat Pump Outdoor Unit

Y Series Standard (32-36hp)

Improved for even higher efficiency

Technical Information

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

� Wrap around coil for improved energy efficiency

� Choice of Branch Pipe or Header Pipe feeds to indoor units

� Energy-saving inverter driven outdoor compressor units with very low start currents

� No requirement for plant rooms or bulky service shafts

� Weight and size reduction compared to YGM-A models

� Improved pipe run of 165m, with a total system pipe length of 1000m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

� High Performance Heating Mode for low ambient conditions

Page 162

Y SERIES STANDARD OUTDOOR UNITS 32-36hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PUHY-P800YSJM-A

100.0

90.0

100.0

87.0

82.8

25.70

27.10

32.38

23.90

17.48

3.89 / 3.32

50

370 / 210

64

290 + 250

1750 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

39.7

41.8

40 / 32

4 + earth

PUHY-P850YSJM-A

108.0

96.0

102.6

95.0

88.3

28.42

29.62

37.80

26.15

18.07

3.80 / 3.24

50

370 / 210

64.5

290 + 250

1750 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

43.9

45.7

40 / 32

4 + earth

PUHY-P900YSJM-A

113.0

101.0

107.4

99.4

92.9

30.05

32.06

39.97

27.65

19.56

3.76 / 3.15

50

370 / 370

65

290 + 290

1750 + 1750

760

1710

380-415v, 50Hz

3

8 / 8

46.4

49.5

40 / 40

4 + earth

Page 87: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PUHY-P950, 1000YSJM-A

PUHY-P1050YSJM-A

Cit

y M

ult

iRange

Y S

erie

s St

andar

d (38-44hp)

Dimensions

Side View > Front View >

Side View > Front View >

Side View > Front View >

PUHY-P1100YSJM-A

Page 165

PUHY-P950-1100YSJM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

1000m max

165m max

40m max

50m max (40m max if outdoor installed below)

15m max

Heat Pump Outdoor Unit

Y Series Standard (38-44hp)

Improved for even higher efficiency

Technical Information

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

� Wrap around coil for improved energy efficiency

� Choice of Branch Pipe or Header Pipe feeds to indoor units

� Energy-saving inverter driven outdoor compressor units with very low start currents

� No requirement for plant rooms or bulky service shafts

� Weight and size reduction compared to YGM-A models

� Improved pipe run of 165m, with a total system pipe length of 1000m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

� High Performance Heating Mode for low ambient conditions

Page 164

Y SERIES STANDARD OUTDOOR UNITS 38-44hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PUHY-P950YSJM-A

119.5

108.0

113.5

105.2

99.4

30.02

30.50

39.93

27.62

18.61

3.98 / 3.54

50

210 / 170 / 170

64.5

250 + 215 + 200

1220 + 920 + 920

760

1710

380-415v, 50Hz

3

8 / 8 / 8

46.4

47.1

32 / 25 / 20

4 + earth

PUHY-P1000YSJM-A

127.0

113.0

120.7

111.8

104.0

33.15

32.10

44.09

30.50

19.58

3.83 / 3.52

50

210 / 170 / 170

64.5

250 + 215 + 215

1220 + 920 + 920

760

1710

380-415v, 50Hz

3

8 / 8 / 8

51.2

49.6

32 / 25 / 25

4 + earth

PUHY-P1050YSJM-A

132.0

118.0

125.4

116.2

108.6

34.10

33.81

45.35

31.37

20.62

3.87 / 3.49

50

210 / 210 / 170

65

250 + 250 + 215

1220 + 1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8 / 8

52.7

52.2

32 / 32 / 25

4 + earth

PUHY-P1100YSJM-A

140.0

124.0

133.0

123.2

114.1

36.08

35.73

47.99

33.19

21.80

3.88 / 3.47

50

210 / 210 / 210

65

250 + 250 + 250

1220 + 1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8 / 8

55.7

55.2

32 / 32 / 32

4 + earth

Page 88: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PUHY-P1150, 1200YSJM-A

PUHY-P1250YSJM-A

Cit

y M

ult

iRange

Y S

erie

s St

andar

d (46-50hp)

Dimensions

Side View > Front View >

Side View > Front View >

Page 167

PUHY-P1150-1250YSJM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

1000m max

165m max

40m max

50m max (40m max if outdoor installed below)

15m max

Heat Pump Outdoor Unit

Y Series Standard (46-50hp)

Improved for even higher efficiency

Technical Information

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

� Wrap around coil for improved energy efficiency

� Choice of Branch Pipe or Header Pipe feeds to indoor units

� Energy-saving inverter driven outdoor compressor units with very low start currents

� No requirement for plant rooms or bulky service shafts

� Weight and size reduction compared to YGM-A models

� Improved pipe run of 165m, with a total system pipe length of 1000m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

� High Performance Heating Mode for low ambient conditions

Page 166

Y SERIES STANDARD OUTDOOR UNITS 46-50hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PUHY-P1150YSJM-A

145.0

130.0

137.8

127.6

119.6

37.27

38.34

49.57

34.29

23.39

3.89 / 3.39

50

370 / 210 / 210

65.5

290 + 250 + 250

1750 + 1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8 / 8

57.6

59.2

40 / 32 / 32

4 + earth

PUHY-P1200YSJM-A

150.0

136.0

142.5

132.0

125.1

39.26

40.84

52.22

36.12

24.91

3.82 / 3.33

50

370 / 210 / 210

66

290 + 250 + 250

1750 + 1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8 / 8

60.6

63.1

40 / 32 / 32

4 + earth

PUHY-P1250YSJM-A

156.5

140.0

148.7

137.7

128.8

40.86

42.94

54.34

37.59

26.19

3.83 / 3.26

50

370 / 370 / 210

66

290 + 290 + 250

1750 + 1750 + 1220

760

1710

380-415v, 50Hz

3

8 / 8 / 8

63.1

66.3

40 / 40 / 32

4 + earth

Page 89: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PUHY-EP400YSJM-A

Side View > Front View >

PUHY-EP200, 250, 300YJM-A

PUHY-EP450YSJM-A

Cit

y M

ult

iRange

Y S

erie

s H

igh C

OP (8-18hp)

Dimensions

Side View > Front View >

PUHY-EP200YJM-A schematic is the same as PUHY-P200, 250, 300YJM-A on page 158

PUHY-EP250YJM-A schematic is the same as PUHY-P350, 400YJM-A on page 158

PUHY-EP300YJM-A schematic is the same as PUHY-P450YJM-A on page 158

Page 169

Heat Pump Outdoor Unit

Y Series High COP (8-18hp)

PUHY-EP200-450Y(S)JM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

1000m max

165m max

40m max

50m max (40m max if outdoor installed below)

15m max

Improved for even higher efficiency

Technical Information

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout,with the choice of either Branch Pipe or Header Pipe feeds to indoor units,with manual changeover from cooling to heating to ensure that a constantindoor climate is maintained.

� Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil

� Choice of Branch Pipe or Header Pipe feeds to indoor units

� Energy-saving inverter driven outdoor compressor units with very low start currents

� No requirement for plant rooms or bulky service shafts

� Weight and size reduction compared to YGM-A models

� Improved pipe run of 165m, with a total system pipe length of 1000m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operationis achievable, the result being greater comfort for occupants

� High Performance Heating Mode for low ambient conditions

Y SERIES HIGH COP OUTDOOR UNITS 8-18hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PUHY-EP200YJM-A

25.0

22.4

25.0

22.8

21.3

5.54

5.09

6.98

5.48

2.93

4.51 / 4.40

17

170

57

200

920

760

1710

380-415v, 50Hz

3

8

8.5

7.8

20

4 + earth

PUHY-EP250YJM-A

31.5

28.0

31.5

28.7

26.6

7.15

6.73

9.01

7.08

3.87

4.40 / 4.16

21

210

60

250

1220

760

1710

380-415v, 50Hz

3

8

11.0

10.4

20

4 + earth

Page 168

PUHY-EP300YJM-A

37.5

33.5

35.6

32.3

31.5

8.37

8.03

11.22

8.12

5.18

4.48 / 4.17

26

370

61

290

1750

760

1710

380-415v, 50Hz

3

8

12.9

12.4

25

4 + earth

PUHY-EP400YSJM-A

50.0

45.0

47.5

43.0

42.3

11.41

10.34

15.29

11.07

6.67

4.38 / 4.35

35

170 / 170

60

200 + 200

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

17.6

15.9

20 / 20

4 + earth

PUHY-EP450YSJM-A

56.0

50.0

50.7

48.7

46.0

12.90

11.87

14.71

11.74

7.48

4.34 / 4.21

39

210 / 170

62

250 + 200

1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8

19.9

18.3

20 / 20

4 + earth

Page 90: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PUHY-EP500YSJM-A

PUHY-EP550YSJM-A

Cit

y M

ult

iRange

Y S

erie

s H

igh C

OP (20-24hp)

Dimensions

PUHY-EP600YSJM-A

Page 171

Side View > Front View >

Side View > Front View >

Side View > Front View >

Heat Pump Outdoor Unit

Y Series High COP (20-24hp)

PUHY-EP500-600YSJM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

1000m max

165m max

40m max

50m max (40m max if outdoor installed below)

15m max

Improved for even higher efficiency

Technical Information

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manualchangeover from cooling to heating to ensure that a constant indoor climate is maintained.

� Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil

� Choice of Branch Pipe or Header Pipe feeds to indoor units

� Energy-saving inverter driven outdoor compressor units with very low start currents

� No requirement for plant rooms or bulky service shafts

� Weight and size reduction compared to YGM-A models

� Improved pipe run of 165m, with a total system pipe length of 1000m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation isachievable, the result being greater comfort for occupants

� High Performance Heating Mode for low ambient conditions

Y SERIES HIGH COP OUTDOOR UNITS 20-24hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

Page 170

PUHY-EP500YSJM-A

63.0

56.0

57.0

54.8

51.5

14.28

13.30

16.28

12.99

8.38

4.41 / 4.21

43

370 / 170

62.5

290 + 200

1750 + 920

760

1710

380-415v, 50Hz

3

8 / 8

22.0

20.5

25 / 20

4 + earth

PUHY-EP550YSJM-A

69.0

63.0

62.4

60.0

58.0

15.78

15.36

17.99

14.36

9.68

4.37 / 4.10

47

370 / 210

63.5

290 + 250

1750 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

24.3

23.7

25 / 20

4 + earth

PUHY-EP600YSJM-A

76.5

69.0

69.2

66.6

63.5

17.30

16.82

19.72

15.74

10.60

4.42 / 4.10

50

370 / 370

64

290 + 290

1750 + 1750

760

1710

380-415v, 50Hz

3

8 / 8

26.7

26.0

25 / 25

4 + earth

Page 91: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Cit

y M

ult

iRange

Y S

erie

s H

igh C

OP (26-30hp)

PUHY-EP650YSJM-A

PUHY-EP700YSJM-A

Dimensions

Side View > Front View >

Side View > Front View >

Side View > Front View >

PUHY-EP750YSJM-A

Page 173

Heat Pump Outdoor Unit

Y Series High COP (26-30hp)

PUHY-EP650-750YSJM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

1000m max

165m max

40m max

50m max (40m max if outdoor installed below)

15m max

Improved for even higher efficiency

Technical Information

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

� Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil

� Choice of Branch Pipe or Header Pipe feeds to indoor units

� Energy-saving inverter driven outdoor compressor units with very low start currents

� No requirement for plant rooms or bulky service shafts

� Weight and size reduction compared to YGM-A models

� Improved pipe run of 165m, with a total system pipe length of 1000m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

� High Performance Heating Mode for low ambient conditions

Page 172

Y SERIES HIGH COP OUTDOOR UNITS 26-30hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PUHY-EP650YSJM-A

81.5

73.0

73.8

70.9

67.2

18.56

17.46

21.16

16.89

11.00

4.39 / 4.18

50

210 / 170 / 170

63

250 + 200 + 200

1220 + 920 + 920

760

1710

380-415v, 50Hz

3

8 / 8 / 8

28.6

26.9

20 / 20 / 20

4 + earth

PUHY-EP700YSJM-A

88.0

80.0

88.0

76.6

73.6

20.00

19.13

25.20

18.60

12.34

4.40 / 4.18

50

370 / 170 / 170

63.5

290 + 200 + 200

1750 + 920 + 920

760

1710

380-415v, 50Hz

3

8 / 8 / 8

30.9

29.5

25 / 20 / 20

4 + earth

PUHY-EP750YSJM-A

95.0

85.0

95.0

82.7

78.2

21.93

20.43

27.63

20.39

13.18

4.33 / 4.16

50

370 / 210 / 170

64.5

290 + 250 + 200

1750 + 1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8 / 8

33.8

31.5

25 / 20 / 20

4 + earth

Page 92: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Cit

y M

ult

iRange

Y S

erie

s H

igh C

OP (32-36hp)

PUHY-EP800YSJM-A

PUHY-EP850YSJM-A

Dimensions

PUHY-EP900YSJM-A

Page 175

Side View > Front View >

Side View > Front View >

Side View > Front View >

PUHY-EP800YSJM-A

100.0

90.0

100.0

87.0

82.8

22.77

21.63

28.69

21.18

13.95

4.39 / 4.16

50

370 / 370 / 170

65

290 + 290 + 200

1750 + 1750 + 920

760

1710

380-415v, 50Hz

3

8 / 8 / 8

35.1

33.4

25 / 25 / 20

4 + earth

PUHY-EP850YSJM-A

108.0

96.0

102.6

95.0

88.3

24.65

23.58

32.78

22.68

14.38

4.38 / 4.07

50

370 / 370 / 210

65.5

290 + 290 + 250

1750 + 1750 + 1220

760

1710

380-415v, 50Hz

3

8 / 8 / 8

38.1

36.4

25 / 25 / 20

4 + earth

PUHY-EP900YSJM-A

113.0

101.0

107.4

99.4

92.9

25.50

24.81

33.92

23.46

15.13

4.43 / 4.07

50

370 / 370 / 370

66

290 + 290 + 290

1750 +1750 + 1750

760

1710

380-415v, 50Hz

3

8 / 8 / 8

39.4

38.3

25 / 25 / 25

4 + earth

Heat Pump Outdoor Unit

Y Series High COP (32-36hp)

PUHY-EP800-900YSJM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

1000m max

165m max

40m max

50m max (40m max if outdoor installed below)

15m max

Improved for even higher efficiency

Technical Information

The City Multi Y Series makes use of a two pipe refrigerant circuit throughout, with the choice of either Branch Pipe or Header Pipe feeds to indoor units, with manual changeover from cooling to heating to ensure that a constant indoor climate is maintained.

� Highest ever COP’s / EER’s due to new higher efficiency inverter technology and wrap around coil

� Choice of Branch Pipe or Header Pipe feeds to indoor units

� Energy-saving inverter driven outdoor compressor units with very low start currents

� No requirement for plant rooms or bulky service shafts

� Weight and size reduction compared to YGM-A models

� Improved pipe run of 165m, with a total system pipe length of 1000m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

� High Performance Heating Mode for low ambient conditions

Page 174

Y SERIES HIGH COP OUTDOOR UNITS 32-36hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

Page 93: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PUHY-HP200, 250YHM-A

PUHY-HP400, 500YSHM-A

Upper View >

Cit

y M

ult

iRange

Y S

erie

s Z

ubad

an (8-20hp)

Dimensions

Upper View >

Front View >Side View >

Page 177

Side View > Front View >

PUHY-HP200-500Y(S)HM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

300m max

150m max

40m max

50m max (40m max if outdoor installed below)

15m max

Heat Pump Outdoor Unit

Y SERIES ZUBADAN OUTDOOR UNITS 8-20hp

Y Series Zubadan (8-20hp)

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

Heating (UK)

Cooling (UK)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

OPERATING RANGE (Outdoor temp ºC) Heating

PUHY-HP200YHM-A

25.0

22.4

28.0

19.9

6.52

6.40

11.02

4.99

3.83 / 3.50

17

225

56

220

920

760

1710

380-415v, 50Hz

3

8

10.0

9.8

32

4 + earth

-25 - 15.5ºC

PUHY-HP250YHM-A

31.5

28.0

35.3

24.9

8.94

9.06

15.11

7.07

3.52 / 3.09

21

225

57

220

920

760

1710

380-415v, 50Hz

3

8

13.8

14.0

32

4 + earth

-25 - 15.5ºC

PUHY-HP400YSHM-A

50.0

45.0

56.0

40.1

13.35

12.86

22.56

10.03

3.74 / 3.49

34

225 / 225

59

220 + 220

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

20.6

19.8

32 / 32

4 + earth

-25 - 15.5ºC

PUHY-HP500YSHM-A

63.0

56.0

70.6

49.8

18.04

18.16

30.49

14.16

3.49 / 3.08

43

225 / 225

60

220 + 220

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

27.8

28.0

32 / 32

4 + earth

-25 - 15.5ºC

Zubadan sets a new standard in performance

Technical Information

The new City Multi Zubadan heat pumps achieve an excellent heating performance even when the outdoor air temperature is as low as -25ºC.

� Stable Heating Performance - Full heating capacity at -15°C- a 40% capacity improvement over the standard YJM-A model

� Expanded Heating Operation - Will work effectively even whenthe outdoor ambient air temperature is -25°C

� Stable Operation - Utilising the new Flash Injection Circuit the Zubadan modelshave reduced defrost times and can provide continuous heating for up to 250 mins

� Quick Start-Up - Full heating capacity is achieved in about 20 mins,improving comfort levels

� Energy-saving inverter driven outdoor compressor units with very low start currents

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operationis achievable, the result being greater comfort for occupants

Page 176

Page 94: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PUHY-RP200, 250, 300, 350YJM-B Upper View >

Cit

y M

ult

iRange

Y S

erie

s R

epla

ce M

ulti (8-26hp)

Dimensions

Front View >Side View >

PUHY-RP400, 450, 500, 550, 600, 650YSJM-B

Upper View >

Side View > Front View >

Page 179

Heat Pump Outdoor Unit

Y Series Replace Multi (8-26hp)

PUHY-RP200-650Y(S)JM-B Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

300m max (250m for size 600-650)

120m max

40m max

50m max (40m max if outdoor installed below)

15m max

Enables the replacement of VRF systems, whilst utilisingexisting R22 / R407c pipework.

Technical Information

The latest VRF Replace Multi from Mitsubishi Electric is specifically designed for the maturingrefurbishment sector, enabling the reuse of existing R22 / R407c pipework, whilst also allowing the upgrade to some of the most efficient systems available in the market.

Replace Multi will clean the existing pipework during commissioning, removing any depositsand R22 mineral oil that would have ordinarily meant that new pipework would have beencalled for. The implications of this are significant savings on cost and time, whilst alsominimising any potential disruption.

n Efficient use of existing resources - refrigerant piping,control and power wiring and less waste materials

n Increased energy efficiency - up to 105% more efficient than an old Mitsubishi Electric R22 system (size 200)

n Reduced installation costs of up to 55%

n Reduced CO2 emissions and running cost savings of up to 45%

n Reduced installation time with minimised disruption

n Ability to replace many non Mitsubishi Electric systems

n High Performance Heating Mode for low ambient conditions

Page 178

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - HRC (A)

MAINS CABLE No. Cores

PUHY-RP200YJM-B

25.0

22.4

25.0

22.8

19.9

5.69

5.68

7.34

5.63

4.43

4.39 / 3.94

17

185

56

230

920

760

1710

380-415v, 50Hz

3

8

8.7

8.7

20

4 + earth

PUHY-RP250YJM-B

31.5

28.0

31.5

28.7

24.9

7.22

7.62

9.31

7.15

5.94

4.36 / 3.67

21

185

57

255

920

760

1710

380-415v, 50Hz

3

8

12.1

12.7

20

4 + earth

PUHY-RP300YJM-B

37.5

33.5

36.0

32.6

31.5

9.42

8.98

12.43

9.14

7.36

3.98 / 3.73

26

185

59

255

920

760

1710

380-415v, 50Hz

3

8

15.2

14.4

25

4 + earth

PUHY-RP350YJM-B

45.0

40.0

43.2

39.2

37.6

12.60

11.79

16.63

12.22

9.67

3.57 / 3.39

30

185

60

255

920

760

1710

380-415v, 50Hz

3

8

20.2

18.9

32

4 + earth

PUHY-RP400YSJM-B

50.0

45.0

48.0

43.5

42.3

11.38

11.87

14.57

11.04

9.73

4.39 / 3.79

32

185 / 185

59

230 + 230

920 + 920

760

1710

380-415v, 50Hz

3

8 + 8

17.5

18.3

20 + 20

4 + earth

PUHY-RP450YSJM-B

56.0

50.0

53.8

48.7

46.0

12.81

13.77

16.40

11.66

9.64

4.37 / 3.63

32

185 / 185

59.5

255 + 230

920 + 920

760

1710

380-415v, 50Hz

3

8 + 8

20.7

22.2

20 + 20

4 + earth

PUHY-RP500YSJM-B

63.0

56.0

60.5

54.8

51.5

14.44

15.68

18.48

13.14

10.98

4.36 / 3.57

32

185 / 185

60

255 + 255

920 + 920

760

1710

380-415v, 50Hz

3

8 + 8

24.2

26.2

20 + 20

4 + earth

PUHY-RP550YSJM-B

69.0

63.0

66.2

60.0

58.0

16.62

17.50

21.27

15.12

12.25

4.15 / 3.60

32

185 / 185

61

255 + 255

920 + 920

760

1710

380-415v, 50Hz

3

8 + 8

27.3

28.7

25 + 20

4 + earth

PUHY-RP600YSJM-B

76.5

69.0

73.4

66.6

63.5

19.22

18.59

24.60

17.49

13.01

3.98 / 3.71

32

185 / 185

62

255 + 255

920 + 920

760

1710

380-415v, 50Hz

3

8 + 8

31.1

30.8

25 + 25

4 + earth

PUHY-RP650YSJM-B

81.5

73.0

78.2

70.9

67.2

21.73

21.09

27.81

19.77

14.76

3.75 / 3.46

32

185 / 185

62.5

255 + 255

920 + 920

760

1710

380-415v, 50Hz

3

8 + 8

35.0

34.0

32 + 25

4 + earth

Y SERIES REPLACE MULTI OUTDOOR UNITS 8-26hp

Page 95: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PUHY-RP700, 750, 800, 850, 900YSJM-B

Cit

y M

ult

iRange

Y S

erie

s R

epla

ce M

ulti (28-36hp)

Dimensions

Upper View >

Side View > Front View >

PUHY-RP700-900YSJM-B Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

250m max

100m max

40m max

50m max (40m max if outdoor installed below)

15m max

Page 180

Y SERIES REPLACE MULTI OUTDOOR UNITS 28-36hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PUHY-RP700YSJM-B

88.0

80.0

84.5

76.6

73.6

20.13

22.22

26.57

18.72

18.66

4.37 / 3.60

32

185 / 185 / 185

61.5

255 + 255 + 230

920 + 920 + 920

760

1710

380-415v, 50Hz

3

8 + 8 + 8

33.0

36.4

20 + 20 + 20

4 + earth

PUHY-RP750YSJM-B

95.0

85.0

91.2

82.7

78.2

21.78

24.14

28.75

20.26

20.28

4.36 / 3.52

32

185 / 185 / 185

62

255 + 255 + 255

920 + 920 + 920

760

1710

380-415v, 50Hz

3

8 + 8 + 8

36.5

39.7

20 + 20 + 20

4 + earth

PUHY-RP800YSJM-B

100.0

90.0

96.0

87.0

82.8

23.75

25.49

31.35

22.09

21.41

4.21 / 3.53

32

185 / 185 / 185

62.5

255 + 255 + 255

920 + 920 + 920

760

1710

380-415v, 50Hz

3

8 + 8 + 8

39.3

42.0

25 + 20 + 20

4 + earth

PUHY-RP850YSJM-B

108.0

96.0

103.7

94.0

88.3

26.47

27.11

34.15

24.09

22.77

4.08 / 3.54

32

185 / 185 / 185

63.5

255 + 255 + 255

920 + 920 + 920

760

1710

380-415v, 50Hz

3

8 + 8 + 8

43.2

44.1

25 + 25 + 20

4 + earth

PUHY-RP900YSJM-B

113.0

101.0

108.5

98.3

92.9

28.39

28.29

36.62

25.83

23.76

3.98 / 3.57

32

185 / 185 / 185

64

255 + 255 + 255

920 + 920 + 920

760

1710

380-415v, 50Hz

3

8 + 8 + 8

45.9

45.7

25 + 25 + 25

4 + earth

Heat Pump Outdoor Unit

Y Series Replace Multi (28-36hp)

Enables the replacement of VRF systems, whilst utilising existing R22 / R407c pipework.

Technical Information

The latest VRF Replace Multi from Mitsubishi Electric is specifically designed for the maturing refurbishment sector,enabling the reuse of existing R22 / R407c pipework, whilst also allowing the upgrade to some of the most efficientsystems available in the market.

Replace Multi will clean the existing pipework during commissioning, removing any deposits and R22 mineral oil thatwould have ordinarily meant that new pipework would have been called for. The implications of this are significantsavings on cost and time, whilst also minimising any potential disruption.

� Tried and tested technology that’s been employed for over 5 years

� Efficient use of existing resources - refrigerant piping,control and power wiring and less waste materials

� Reduced installation costs of up to 55%

� Reduced CO2 emissions and increased energy efficiencyresulting in running cost savings of up to 45%

� Reduced installation time with minimised disruption

� Ability to replace many non Mitsubishi Electric systems

� High Performance Heating Mode for low ambient conditions

Page 181

Page 96: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PQHY-P200, 250, 300YHM-A

PQHY-P400, 450, 500, 550, 600YSHM-A

Upper View >

Front View > Right Side View >

Front View >Left Side View >

Cit

y M

ult

iRange

WY

Ser

ies (8-24hp)

Dimensions

Page 183

WY SERIES HEAT SOURCE UNITS - 8-24hp

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1100 without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

WY Series (8-24hp)Heat Pump, Water Cooled Condensing Unit

PQHY-P200-600Y(S)HM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

300m max for sizes 200-300 / 500m max for sizes 400-600

165m max

40m max

50m max (40m max if outdoor installed below)

15m max

Technical Information

� High COPs possible thanks to increased efficiency and careful control of the system, allowing the largest operational water circuit temperature band ever

� 40% height reduction compared to previous YGM-A models

� Combining WY with waste heat energy provides unique application solutions

� Up to 50 indoor units can now be connected to each condensing unit

� Single inverter compressor

� Improved pipe run of 165m with a total system pipe length of up to 500m

� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

� Able to operate with closed loop ground source water temperatures, bore hole and slinky applications are now possible

� Easy maintenance - front panel access to all PCB’s

� Condensing units must be situated indoors

Page 182

The WY Series has all the benefits of the Y Series using water cooled condensing units. It is also able to produce heatrecovery via the water circuit between heat source units, making for a very economical system. Like the YJM-A airsource versions, the water cooled units now benefit from a modular design approach. A twinning kit is required fordouble combinations.

PQHY-P200YHM-A

25.0

22.4

4.12

3.92

6.06 / 5.71

17

47

195

880

550

1160

380-415v, 50Hz

3

8

6.3

6.0

20

4 + earth

PQHY-P250YHM-A

31.5

28.0

5.80

5.45

5.43 / 5.13

21

49

195

880

550

1160

380-415v, 50Hz

3

8

8.9

8.4

20

4 + earth

PQHY-P300YHM-A

37.5

33.5

8.15

7.36

4.60 / 4.55

26

50

195

880

550

1160

380-415v, 50Hz

3

8

12.5

11.3

20

4 + earth

PQHY-P400YSHM-A

50.0

45.0

8.65

8.25

5.78 / 5.45

34

50

195 + 195

880 + 880

550

1160

380-415v, 50Hz

3

8 / 8

13.3

12.7

20 / 20

4 + earth

PQHY-P450YSHM-A

56.0

50.0

10.42

9.84

5.37 / 5.08

39

51

195 + 195

880 + 880

550

1160

380-415v, 50Hz

3

8 / 8

16.1

15.2

20 / 20

4 + earth

PQHY-P500YSHM-A

63.0

56.0

12.06

11.45

5.22 / 4.89

43

52

195 + 195

880 + 880

550

1160

380-415v, 50Hz

3

8 / 8

18.6

17.6

20 / 20

4 + earth

PQHY-P550YSHM-A

69.0

63.0

14.65

13.46

4.70 / 4.68

47

52.5

195 + 195

880 + 880

550

1160

380-415v, 50Hz

3

8 / 8

22.6

20.8

20 / 20

4 + earth

PQHY-P600YSHM-A

76.5

69.0

17.12

15.48

4.46 / 4.45

50

53

195 + 195

880 + 880

550

1160

380-415v, 50Hz

3

8 / 8

26.4

23.9

20 / 20

4 + earth

Page 97: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PQHY-P650, 700, 750, 800, 850, 900YSHM-A

Upper View >

Front View >Left Side View > Cit

y M

ult

iRange

WY

Ser

ies (26-36hp)

Dimensions

Page 185

� High COPs possible thanks to increased efficiency and careful control of the system, allowing the largestoperational water circuit temperature band ever

� 40% height reduction compared to previous YGM-A models

� Combining WY with waste heat energy provides unique application solutions

� Up to 50 indoor units can now be connected to each condensing unit

� Single inverter compressor

� Improved pipe run of 165m with a total system pipe length of up to 500m

� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensiblecooling capacity over standard operation is achievable, the result being greater comfort for occupants

� Able to operate with closed loop ground sourcewater temperatures, bore hole and slinkyapplications are now possible

� Easy maintenance - front panel access to all PCB’s

� Condensing units must be situated indoors

WY SERIES HEAT SOURCE UNITS - 26-36hp

MODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1100 without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

WY Series (26-36hp)Heat Pump, Water Cooled Condensing Unit

PQHY-P650-900YSHM-A Piping Restrictions

TOTAL PIPING LENGTH

FURTHEST PIPING LENGTH

FURTHEST PIPING LENGTH AFTER 1st BRANCH

BETWEEN INDOOR AND OUTDOOR UNITS - HEIGHT

BETWEEN INDOOR AND INDOOR UNITS - HEIGHT

500m max

165m max

40m max

50m max (40m max if outdoor installed below)

15m max

Technical Information

Page 184

The WY Series has all the benefits of the Y Series using water cooled condensing units. It is also able to produce heatrecovery via the water circuit between heat source units, making for a very economical system. Like the YJM-A airsource versions, the water cooled units now benefit from a modular design approach. A twinning kit is required.

PQHY-P650YSHM-A

81.5

73.0

14.74

13.96

5.52 / 5.22

50

53

195 + 195 + 195

880 + 880 + 880

550

1160

380-415v, 50Hz

3

8 / 8 / 8

22.7

21.5

20 / 20 / 20

4 + earth

PQHY-P700YSHM-A

88.0

80.0

16.51

15.58

5.33 / 5.13

50

53.5

195 + 195 + 195

880 + 880 + 880

550

1160

380-415v, 50Hz

3

8 / 8 / 8

25.5

24.0

20 / 20 / 20

4 + earth

PQHY-P750YSHM-A

95.0

85.0

18.27

17.19

5.19 / 4.94

50

54

195 + 195 + 195

880 + 880 + 880

550

1160

380-415v, 50Hz

3

8 / 8 / 8

28.2

26.5

20 / 20 / 20

4 + earth

PQHY-P800YSHM-A

100.0

90.0

20.74

19.18

4.82 / 4.69

50

54

195 + 195 + 195

880 + 880 + 880

550

1160

380-415v, 50Hz

3

8 / 8 / 8

32.0

29.6

20 / 20 / 20

4 + earth

PQHY-P850YSHM-A

108.0

96.0

23.21

21.20

4.65 / 4.52

50

54.5

195 + 195 + 195

880 + 880 + 880

550

1160

380-415v, 50Hz

3

8 / 8 / 8

35.8

32.7

20 / 20 / 20

4 + earth

PQHY-P900YSHM-A

113.0

101.0

25.67

23.22

4.40 / 4.34

50

55

195 + 195 + 195

880 + 880 + 880

550

1160

380-415v, 50Hz

3

8 / 8 / 8

39.6

35.8

20 / 20 / 20

4 + earth

Page 98: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Upper View >Front View >Side View >

Cit

y M

ult

iRange

R2 S

erie

s St

andar

d (8-18hp)

PURY-P200, 250, 300YJM-A

Upper View >Front View >Side View >

PURY-P350, 400YJM-A

Upper View >Front View >Side View >

PURY-P450YJM-A

Dimensions

Page 187

R2 Series Standard (8-18hp)Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

Improved for even higher efficiency

Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and viceversa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems.

� New higher efficiency inverter technology, with low start currents and wrap around coil for added efficiency

� Up to 45 indoor units connected to each outdoor unit

� Easy to install unique 2-pipe technology means minimal disruption,quicker installation and less connections than 3 pipe equivalents

� Weight and size reduction compared to YGM-A models

� Improved pipe run of 165m with a total systempipe length of up to 600m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation isachievable, the result being greater comfort for occupants

� High Performance Heating Mode forlow ambient conditions

Page 186

R2 SERIES STANDARD OUTDOOR UNITS 8-18hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PURY-P200YJM-A

25.0

22.4

25.0

22.8

21.3

5.69

5.18

7.17

5.63

2.98

4.39 / 4.32

20

185

56

240

920

760

1710

380-415v, 50Hz

3

8

8.7

8.0

20

4 + earth

PURY-P250YJM-A

31.5

28.0

31.5

28.7

26.6

7.32

7.05

9.22

7.25

4.05

4.30 / 3.97

25

185

57

240

920

760

1710

380-415v, 50Hz

3

8

11.3

10.8

20

4 + earth

PURY-P300YJM-A

37.5

33.5

35.6

32.3

31.5

8.78

8.67

11.77

8.52

5.59

4.27 / 3.86

30

185

59

245

920

760

1710

380-415v, 50Hz

3

8

13.5

13.4

25

4 + earth

PURY-P350YJM-A

45.0

40.0

42.8

38.7

37.6

10.89

11.33

14.59

10.56

7.31

4.13 / 3.53

35

225

60

270

1220

760

1710

380-415v, 50Hz

3

8

16.8

17.5

32

4 + earth

PURY-P450YJM-A

56.0

50.0

50.7

48.7

46.0

14.58

14.49

16.62

13.27

9.13

3.84 / 3.45

45

360

62

320

1750

760

1710

380-415v, 50Hz

3

8

22.5

22.3

40

4 + earth

PURY-P400YJM-A

50.0

45.0

47.5

43.0

42.3

12.75

13.55

17.09

12.37

8.74

3.92 / 3.32

40

225

61

270

1220

760

1710

380-415v, 50Hz

3

8

19.7

20.9

40

4 + earth

Technical Information

Note: For piping restrictions for PURY-P200-450YJM-A please see page 196

Page 99: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Cit

y M

ult

iRange

R2 S

erie

s St

andar

d (18-28hp)

PURY-P450YSJM-A1 / PURY-P500, 550, 600YSJM-A

PURY-P650, 700YSJM-A

Dimensions

Side View > Front View >

Page 189

Side View > Front View >

R2 Series Standard (18-28hp)Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

Improved for even higher efficiency

Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems.

� New higher efficiency inverter technology, with low start currents and wrap around coil for added efficiency

� Up to 50 indoor units connected to each outdoor unit

� Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents

� Weight and size reduction compared to YGM-A models

� Improved pipe run of 165m with a total system pipe length of up to 950m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

� High Performance Heating Mode for low ambient conditions

Page 188

Technical Information

R2 SERIES STANDARD OUTDOOR UNITS 18-28hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PURY-P450YSJM-A1

56.0

50.0

50.7

48.7

46.0

13.30

12.50

15.16

12.10

7.88

4.21 / 4.00

45

185 / 185

59.5

240 + 240

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

20.5

19.3

20 / 20

4 + earth

PURY-P500YSJM-A

63.0

56.0

57.0

54.8

51.5

15.10

14.85

17.21

13.74

9.36

4.17 / 3.77

50

185 / 185

60

240 + 240

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

23.3

22.9

20 / 20

4 + earth

PURY-P550YSJM-A

69.0

63.0

62.4

60.0

58.0

16.95

17.30

19.32

15.42

10.90

4.07 / 3.64

50

185 / 185

61

245 + 240

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

26.2

26.7

25 / 20

4 + earth

PURY-P600YSJM-A

76.5

69.0

69.2

66.6

63.5

19.07

19.65

21.74

17.35

12.38

4.01 / 3.51

50

185 / 185

62

245 + 245

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

29.4

30.3

25 / 25

4 + earth

PURY-P700YSJM-A

88.0

80.0

88.0

76.6

73.6

22.33

23.95

28.14

20.77

15.45

3.94 / 3.34

50

225 / 185

63

270 + 245

1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8

34.5

37.0

40 / 25

4 + earth

PURY-P650YSJM-A

81.5

73.0

73.8

70.9

67.2

20.47

21.53

23.34

18.63

13.56

3.98 / 3.39

50

225 / 185

62.5

270 + 245

1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8

31.6

33.2

32 / 25

4 + earth

Note: For piping restrictions for PURY-P450-700YSJM-A(1) please see page 196

Page 100: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Cit

y M

ult

iRange

R2 S

erie

s St

andar

d (30-36hp)

PURY-P750, 800YSJM-A

PURY-P850YSJM-A

Dimensions

Side View > Front View >

Side View > Front View >

Side View > Front View >

PURY-P900YSJM-A

Page 191

R2 Series Standard (30-36hp)Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

Improved for even higher efficiency

Throughout the year, many buildings require cooling in some areas andheating in others - even in adjacent rooms. The outstanding City Multi R2 system meets this requirement by distributing surplus heat fromcooling operations (and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% over conventional systems.

� New higher efficiency inverter technology, with low start currents and wrap around coil for added efficiency

� Up to 50 indoor units connected to each outdoor unit

� Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents

� Weight and size reduction compared to YGM-A models

� Improved pipe run of 165m with a total system pipe length of up to 950m

� 100% inverter control

� High Sensible Cooling Function - By raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

� High Performance Heating Mode for low ambient conditions

Page 190

Note: For piping restrictions for PURY-P750-900YSJM-A please see page 196

Technical Information

R2 SERIES STANDARD OUTDOOR UNITS 30-36hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

PURY-P750YSJM-A

95.0

85.0

95.0

82.7

78.2

24.05

26.47

30.30

22.37

17.07

3.95 / 3.21

50

225 / 225

63.5

270 + 270

1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

37.1

40.9

40 / 32

4 + earth

PURY-P800YSJM-A

100.0

90.0

100.0

87.0

82.8

26.04

28.30

32.81

24.22

18.25

3.84 / 3.18

50

225 / 225

64

270 + 270

1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

40.2

43.7

40 / 40

4 + earth

PURY-P850YSJM-A

108.0

96.0

102.6

95.0

88.3

28.42

29.26

37.80

26.15

17.85

3.80 / 3.28

50

360 / 225

64.5

320 + 270

1750 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

43.9

45.2

40 / 40

4 + earth

PURY-P900YSJM-A

113.0

101.0

107.4

99.4

92.9

30.05

30.23

39.97

27.65

18.44

3.76 / 3.34

50

360 / 360

65

320 + 320

1750 + 1750

760

1710

380-415v, 50Hz

3

8 / 8

46.4

46.7

40 / 40

4 + earth

Page 101: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Side View > Front View >

Side View > Front View >

PURY-EP400YSJM-A

PURY-EP200, 250, 300, 350YJM-A

PURY-EP450, 500YSJM-A

Cit

y M

ult

iRange

R2 S

erie

s H

igh C

OP (8-20hp)

Dimensions

Page 193

PURY-EP200YJM-A schematic is the same as PURY-P200, 250, 300YJM-A on page 186

PURY-EP250, 300YJM-A schematic is the same as PURY-P350, 400YJM-A on page 186

PURY-EP350YJM-A schematic is the same as PURY-P450YJM-A on page 186

R2 Series High COP (8-20hp)Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

Improved for even higher efficiency

Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms.The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations(and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30% overconventional systems.

� Highest ever COP’s / EER’s due to new high efficiency inverter technologyand wrap around coil for added efficiency

� Up to 50 indoor units connected to each outdoor unit

� Easy to install unique 2-pipe technology means minimal disruption,quicker installation and less connections than 3 pipe equivalents

� Weight and size reduction compared to YGM-A models

� Improved pipe run of 165m with a total system pipe length of up to 750m

� 100% inverter control with low start currents

� High Sensible Cooling Function - By raising the off coil temperature, a 10% increasein sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

� High Performance Heating Modefor low ambient conditions

Technical Information

R2 SERIES HIGH COP OUTDOOR UNITS 8-20hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

Page 192

PURY-EP200YJM-A

25.0

22.4

25.0

22.8

21.3

5.56

5.07

7.01

5.50

2.92

4.49 / 4.41

20

185

57

240

920

760

1710

380-415v, 50Hz

3

8

8.5

7.8

20

4 + earth

PURY-EP250YJM-A

31.5

28.0

31.5

28.7

26.6

7.15

6.76

9.01

7.08

3.89

4.40 / 4.14

25

225

60

270

1220

760

1710

380-415v, 50Hz

3

8

11.0

10.4

20

4 + earth

PURY-EP300YJM-A

37.5

33.5

35.6

32.3

31.5

8.60

8.25

11.52

8.34

5.32

4.36 / 4.06

30

225

60

270

1220

760

1710

380-415v, 50Hz

3

8

13.2

12.7

25

4 + earth

PURY-EP350YJM-A

45.0

40.0

42.8

38.7

37.6

10.58

10.28

14.18

10.26

6.63

4.25 / 3.89

35

360

61

320

1750

760

1710

380-415v, 50Hz

3

8

16.3

15.8

32

4 + earth

PURY-EP400YSJM-A

50.0

45.0

47.5

43.0

42.3

11.36

10.41

15.22

11.02

6.71

4.40 / 4.32

40

185 / 185

60

240 + 240

920 + 920

760

1710

380-415v, 50Hz

3

8 / 8

17.5

16.0

20 / 20

4 + earth

PURY-EP450YSJM-A

56.0

50.0

50.7

48.7

46.0

12.87

11.99

14.67

11.71

7.55

4.35 / 4.17

45

225 / 185

62

270 + 240

1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8

19.8

18.5

20 / 20

4 + earth

PURY-EP500YSJM-A

63.0

56.0

57.0

54.8

51.5

14.38

13.62

16.39

13.09

8.58

4.38 / 4.11

50

225 / 185

62

270 + 240

1220 + 920

760

1710

380-415v, 50Hz

3

8 / 8

22.2

21.0

25 / 20

4 + earth

Note: For piping restrictions for PURY-EP200-500Y(S)JM-A please see page 196

Page 102: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Side View > Front View >

PURY-EP550, 600YSJM-A

PURY-EP650YSJM-A

Cit

y M

ult

iRange

R2 S

erie

s H

igh C

OP (22-28hp)

Dimensions

PURY-EP700YSJM-A

Page 195

Side View > Front View >

Side View > Front View >

R2 Series High COP (22-28hp)Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

Improved for even higher efficiency

Throughout the year, many buildings require cooling in some areas and heating in others - even in adjacent rooms.The outstanding City Multi R2 system meets this requirement by distributing surplus heat from cooling operations(and vice versa) to rooms where it is needed. This efficiency can result in energy savings of up to 30%over conventional systems.

� Highest ever COP’s / EER’s due to new high efficiency inverter technologyand wrap around coil for added efficiency

� Up to 50 indoor units connected to each outdoor unit

� Easy to install unique 2-pipe technology means minimal disruption, quicker installation and less connections than 3 pipe equivalents

� Weight and size reduction compared to YGM-A models

� Improved pipe run of 165m with a total system pipe length of up to 800m

� 100% inverter control with low start currents

� High Sensible Cooling Function - By raising the off coil temperature,a 10% increase in sensible cooling capacity over standard operationis achievable, the result being greater comfort for occupants

� High Performance Heating Modefor low ambient conditions

Technical Information

R2 SERIES HIGH COP OUTDOOR UNITS 22-28hpMODEL REFERENCE

CAPACITY (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

POWER INPUT (kW) Heating (nominal)

Cooling (nominal)

High Performance Heating (UK)

COP Priority Heating (UK)

Cooling (UK)

COP / EER (nominal)

MAX No. OF CONNECTABLE INDOOR UNITS

AIRFLOW (m3/min) High

NOISE (dBA)

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

(1650mm without legs) Height

ELECTRICAL SUPPLY

PHASE

STARTING CURRENT (A)

RUNNING CURRENT (A) Heating

Cooling

FUSE RATING (MCB sizes BS EN 60947-2) - (A)

MAINS CABLE No. Cores

Page 194

PURY-EP550YSJM-A

69.0

63.0

62.4

60.0

58.0

15.93

15.40

18.16

14.50

9.70

4.33 / 4.09

50

225 / 225

63

270 + 270

1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

24.6

23.8

25 / 20

4 + earth

PURY-EP600YSJM-A

76.5

69.0

69.2

66.6

63.5

17.38

16.87

19.81

15.82

10.63

4.40 / 4.09

50

225 / 225

63

270 + 270

1220 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

26.8

26.0

25 / 25

4 + earth

PURY-EP650YSJM-A

81.5

73.0

73.8

70.9

67.2

19.73

19.01

22.49

17.95

11.98

4.13 / 3.84

50

360 / 225

63.5

320 + 270

1750 + 1220

760

1710

380-415v, 50Hz

3

8 / 8

30.4

29.3

32 / 25

4 + earth

PURY-EP700YSJM-A

88.0

80.0

88.0

76.6

73.6

22.05

21.22

27.78

20.51

13.69

3.99 / 3.77

50

360 / 360

64

320 + 320

1750 + 1750

760

1710

380-415v, 50Hz

3

8 / 8

34.0

32.8

32 / 32

4 + earth

Note: For piping restrictions for PURY-EP550-700YSJM-A please see page 196

Page 103: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Cit

y M

ult

iRange

R2 S

erie

s Pip

ing

Res

tric

tions

1

ITEM PIPE SECTION MAX LENGTH

R2 SERIES PIPING RESTRICTIONS

PIPING LENGTH (>1 BC CONTROLLER FOR 1 OUTDOOR UNIT)

Total Piping Length

Furthest Piping Length

Length Between OU and BC

Length Between Furthest IU and BC

Height Between OU and IU (OU above IU)

Height Between OU and IU (OU below IU)

Height Between IU and BC

Height Between IU and IU

Height Between BC (Main or Sub) and BC (Sub)

A+B+C+D+E+a+b+c+d+e+f

A+C+E+f

A

B+d or C+D+e or C+E+f

H

H1

h1

h2

h3

(See Table 1)

165m

110m*1

60m*2 (40m)

50m

40m

15m

15m

15m

*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

ITEM PIPE SECTION MAX LENGTH

R2 SERIES PIPING RESTRICTIONS

PIPING LENGTH (>1 BC CONTROLLER FOR 2 OUTDOOR UNITS)

Total Piping Length

Furthest Piping Length

Length Between OU and BC

Length Between Furthest IU and BC

Height Between OU and IU (OU above IU)

Height Between OU and IU (OU below IU)

Height Between IU and BC

Height Between IU and IU

Height Between BC (Main or Sub) and BC (Sub)

Length Between Main OU and Sub OU

Height Between Main OU and Sub OU

F+G+H+A+B+C+D+E+a+b+c+d+e+f

F(G)+A+C+E+f

F(G)+A

B+d or C+D+e or C+E+f

H

H1

h1

h2

h3

F+G or H

h4

(See Table 1)

165m

110m*1

60m*2 (40m)

50m

40m

15m

15m

15m

5m

0.1m

*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

1

700 to P800/ EP600 or less

CMY-R100XLVBK: Outdoor unit EP650 and EP700CMY-R200XLVBK: Outdoor unit P850 and P900

Page 197

OUTDOOR MODEL

TABLE 1: TOTAL PIPE LENGTH

R2 SERIES PIPING RESTRICTIONS

GRAPH 1: TOTAL PIPING LENGTH RESTRICTIONS

P200, P250, P300, EP200P350, P400, P450, EP250, EP300, EP350P500, P550, EP400, EP450, EP500, EP550P600, P650, EP600, EP650, EP700P700, P750, P800, P850, P900

550m*1

600m*1

750m*1

800m*1

950m*1

*1 Please refer to Graph 1

1000

PURY-P700,750,800,850,900YSJM-A

PURY-P600,650YSJM-A, PURY-EP600,650,700YSJM-A

PURY-P500,550YSJM-A, PURY-EP400,450,500,550YSJM-A

PURY-P350,400,450Y(S)JM-A(1), PURY-EP250,300,350YJM-A

PURY-P200,250,300YJM-A, PURY-EP200YJM-A

900

800

700

600

500

400

300

200

100

0

10 20 30 40 50 60 70 80 90 100 110

Tota

l Exte

nded

Pip

e Le

ngt

h (

m)

Distance Between Outdoor Unit and BC Controller (m)

1

1

R2 SERIES PIPING RESTRICTIONS

ITEM PIPE SECTION MAX LENGTH

R2 SERIES PIPING RESTRICTIONS

PIPING LENGTH (1 BC CONTROLLER, NO SUB BC CONTROLLER)

Total Piping Length

Furthest Piping Length

Length Between OU and BC

Length Between Furthest IU and BC

Height Between OU and IU (OU above IU)

Height Between OU and IU (OU below IU)

Height Between IU and BC

Height Between IU and IU

A+B+a+b+c+d

A+B+d

A

B+d

H

H1

h1

h2

(See Table 1)

165m

110m*1

60m*2 (40m)

50m

40m

15m

15m

*1 Please refer to Graph 1. *2 Height difference between BC controller and furthest indoor unit is zero.

R2 Series Piping Restrictions

Page 196

MAX LENGTH

Page 104: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

cit

y m

ult

iR

ange

r2

seri

es r

epla

ce m

ulti (

8-12

hp)

PURY-RP200, 250, 300YJM-B upper view >

Dimensions

Front view >side view >

Page 199

Simultaneous Heating and Cooling with Heat Recovery Outdoor Unit

r2 series replace multi (8-12hp)

enables the replacement of vrF systems, whilst utilisingexisting r22 / r407c pipework.

Technical Information

The latest VRF Replace Multi from Mitsubishi Electric is specifically designed for the maturing refurbishment sector,enabling the reuse of existing R22 / R407c pipework, whilst also allowing the upgrade to some of the most efficientsystems available in the market.

Replace Multi will clean the existing pipework during commissioning, removing any deposits and R22 mineral oil thatwould have ordinarily meant that new pipework would have been called for. The implications of this are significantsavings on cost and time, whilst also minimising any potential disruption.

� tried and tested technology that has been employed for over 5 years

� efficient use of existing resources - refrigerant piping,control and power wiring and less waste materials

� increased energy efficiency - up to 105% (size 200) moreefficient than an old mitsubishi electric r22 system

� reduced installation costs of up to 55%

� reduced co2 emissions and running cost savings of up to 45%

� reduced installation time with minimised disruption

� ability to replace many non mitsubishi electric systems

� high Performance heating mode for low ambient conditions

Page 198

R2 SERIES REPLACE MULTI OUTDOOR UNITS 8-12hpmodel reFerence

caPacity (kw) heating (nominal)

cooling (nominal)

high Performance heating (uK)

coP Priority heating (uK)

cooling (uK)

Power inPut (kw) heating (nominal)

cooling (nominal)

high Performance heating (uK)

coP Priority heating (uK)

cooling (uK)

coP / eer (nominal)

max no. oF connectable indoor units

airFlow (m3/min) high

noise (dba)

weight (kg)

dimensions (mm) width

depth

(1650mm without legs) height

electrical suPPly

Phase

starting current (a)

running current (a) heating

cooling

Fuse rating (mcb sizes bs en 60947-2) - (a)

mains cable no. cores

PURY-RP200YJM-B

25.0

22.4

24.0

21.8

21.1

5.50

4.95

7.26

5.34

3.61

4.54 / 4.52

20

225

56

275

1220

760

1710

380-415v, 50hz

3

8

8.9

8.0

20

4 + earth

PURY-RP250YJM-B

31.5

28.0

30.2

27.4

26.3

7.22

6.82

9.53

7.00

4.98

4.36 / 4.10

25

225

57

290

1220

760

1710

380-415v, 50hz

3

8

11.9

11.2

20

4 + earth

PURY-RP300YJM-B

37.5

33.5

36.0

32.6

31.5

8.70

8.35

11.48

8.44

6.10

4.31 / 4.01

30

225

59

290

1220

760

1710

380-415v, 50hz

3

8

14.6

13.6

25

4 + earth

R2 Series Replace Multi Piping Restrictions

total PiPing length 220m max

Furthest PiPing length 100m max

length between ou and bc 70m max

length between Furthest iu and bc 30m max

height between ou and iu (ou above iu) 50m max

height between ou and iu (ou below iu) 40m max

height between iu and bc 15m max

height between iu and iu 15m max

height between bc (main or sub) and sub bc 15m max

Page 105: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

cit

y m

ult

iR

ange

wr

2 se

ries

(8-

24hp

)

PQRY-P200, 250, 300YHM-A

PQRY-P400, 450, 500, 550, 600YSHM-A

upper view >

Front view > right side view >

Front view >left side view >

Dimensions

Page 201

WR2 SERIES HEAT SOURCE UNITS - 8-24hp

model reFerence

caPacity (kw) heating (nominal)

cooling (nominal)

Power inPut (kw) heating (nominal)

cooling (nominal)

coP / eer (nominal)

max no. oF connectable indoor units

noise (dba)

weight (kg)

dimensions (mm) width

depth

(1100 without legs) height

electrical suPPly

Phase

starting current (a)

running current (a) heating

cooling

Fuse rating (bs88) - hrc (a)

mains cable no. cores

PQRY-P200YHM-A

25.0

22.4

4.12

3.96

6.06 / 5.65

20

47

181

880

550

1160

380-415v, 50hz

3

8

6.3

6.1

20

4 + earth

PQRY-P250YHM-A

31.5

28.0

5.80

5.51

5.43 / 5.08

25

49

181

880

550

1160

380-415v, 50hz

3

8

8.9

8.5

20

4 + earth

PQRY-P300YHM-A

37.5

33.5

8.15

7.44

4.60 / 4.50

30

50

181

880

550

1160

380-415v, 50hz

3

8

12.5

11.5

20

4 + earth

PQRY-P400YSHM-A

50.0

45.0

8.65

8.32

5.78 / 5.40

40

50

181 + 181

880 + 880

550

1160

380-415v, 50hz

3

8 / 8

13.3

12.8

20 / 20

4 + earth

PQRY-P450YSHM-A

56.0

50.0

10.42

9.94

5.37 / 5.03

45

51

181 + 181

880 + 880

550

1160

380-415v, 50hz

3

8 / 8

16.1

15.3

20 / 20

4 + earth

PQRY-P500YSHM-A

63.0

56.0

12.06

11.57

5.22 / 4.84

50

52

181 + 181

880 + 880

550

1160

380-415v, 50hz

3

8 / 8

18.6

17.8

20 / 20

4 + earth

PQRY-P550YSHM-A

69.0

63.0

14.65

13.60

4.70 / 4.63

50

52.5

181 + 181

880 + 880

550

1160

380-415v, 50hz

3

8 / 8

22.6

21.0

20 / 20

4 + earth

PQRY-P600YSHM-A

76.5

69.0

17.12

15.62

4.46 / 4.41

50

53

181 + 181

880 + 880

550

1160

380-415v, 50hz

3

8 / 8

26.4

24.1

20 / 20

4 + earth

wr2 series (8-24hp)Water Cooled Condensing UnitSimultaneous Heating and Cooling with Double Heat Recovery

PQRY-P200-600Y(S)HM-A Piping restrictions

total PiPing length

Furthest PiPing length

between outdoor and bc controller (master) - length

between indoor and bc controller (master/slave) - length

between indoor and outdoor - height

between indoor and indoor - height

between indoor and bc controller (master/slave) - height

between bc controller (master) and bc controller (slave) - height

550m max*3 (300m) for sizes 200-300 / 750m max*3 (500m) for sizes 400-600

165m max

110m max*4

60m max*5 (40m)

50m max (40m*1)

15m max (10m*2)

15m max (10m*2)

15m max (10m)*6

Technical Information

The WR2 system has double heat recovery potential, making this system very economical. Not only does it produceheat recovery from indoor units on the same refrigerant circuit, it also produces heat recovery via the water circuitbetween heat source units. Like the YHM-A air source versions, the water cooled units now benefit from a modulardesign approach. A twinning kit is required for double combinations.

� all the benefits of the r2 series with water cooled condensing units, using a single inverter compressor

� 40% height reduction compared to previous ygm-a models

� high coPs possible thanks to increased efficiency and careful control of the system, allowing the largest operational water circuit temperature band ever

� unique 2-pipe refrigerant circuit allows simultaneous heating and cooling plus heat recovery between up to 50 indoor units as with the r2 system

� total building heat recovery made possible by exchanging energy in both refrigerant and water circuits

� combining wr2 with waste heat energy provides unique application solutions

� improved pipe run of 165m with a total system pipe length of up to 750m

� high sensible cooling Function - by raising the off coil temperature, a 10% increase in sensible cooling capacity over standard operation is achievable, the result being greater comfort for occupants

� able to operate with closed loop ground source water temperatures,bore hole and slinky applications are now possible

� easy maintenance - front panel access to all Pcb’s

� condensing units must be situated indoors

Page 200

*1 When O/U is below indoor *2 In case of P200, P250 indoor unit *3 Distance between outdoor unit and BC Controller is 10m or less *4 Total piping length is 300m or less (500m for sizes 400-600) *5 Height difference between the Master BC Controller and furthest indoor unit is zero and no size 200 or 250 indoor unit is used *6 When using 2 sub BC Controllers, the height between them should be considered

Page 106: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PFD-P250VM-E

PFD-P500VM-E

upper view >

Front view > side view >

upper view >

Front view > side view >

cit

y m

ult

iR

ange

PFd

-P-v

m-e

(10

/20h

p)

Dimensions

Page 203

Heat Pump Close Control System

PFd-P-vm-e (10/20hp)

PUHY-P-YJM-A - OUTDOOR UNITSPFD-P-VM-E - INDOOR UNITS

model reFerence

caPacity (kw) heating (nominal)

cooling (nominal)

heating (uK)

cooling (uK)

shF

Power inPut (kw) heating (nominal)

cooling (nominal)

heating (uK)

cooling (uK)

airFlow (m3/min)

external static Pressure (Pa)

PiPe siZe mm(in) gas

liquid

noise (dba)

weight (kg)

dimensions (mm) width

depth

height

electrical suPPly

Phase

starting current (a)

running current (a) heating

cooling

Fuse rating (bs88) - hrc (a)

mains cable no. cores

PFD-P250VM-E

31.5

28.0

29.1

26.6

0.93

2.5

2.5

n/a

n/a

160

120

22.2 (7/8”)

9.52 (3/8”)

59

380

1380

780

1950

380-415v, 50hz

3

47

4.9

4.9

16

4 + earth

PFD-P500VM-E

63.0

56.0

55.4

51.5

0.93

5.0

5.0

n/a

n/a

320

120

22.2 (7/8”)

9.52 (3/8”)

63

520

1980

780

1950

380-415v, 50hz

3

68

8.7

8.7

20

4 + earth

PFD-P-VM-E Piping restrictions

total PiPing length

between indoor and outdoor units - height

165m max

50m max (40m max if outdoor installed below)

Technical Information

Mitsubishi Electric’s new Close Control System is specifically designed forcomputer rooms, laboratories etc, where a need for high sensible cooling andclose control of temperature and humidity is required. Because of the needfor close control 24 hours a day, 365 days a year, a newly developed inverterdriven compressor has been incorporated into the outdoor unit, maximisingthe energy efficiency of the PFD series. It is also able to be connected to a computer network using our AG150 controller, in order to monitor andprovide remote email alarms.

� high sensible cooling

� newly developed inverter driven compressor

� energy efficient with high coP’s

� close control of temperature, ±1ºc

� easy to install - no service space needed at the rear of the unit

� optional third party humidifier available

� Quick recovery following power failure

� return or discharge air temperature control

� back-up & rotate function available

� connectable to Puhy-P250yJm-a from april 2011

Page 202

PUHY-P250YJM-A

31.5

28.0

28.7

26.6

n/a

refer to databook

refer to databook

refer to databook

refer to databook

170

n/a

22.2 (7/8”)

9.52 (3/8”)

58

200

920

760

1710

380-415v, 50hz

3

8

refer to databook

refer to databook

20

4 + earth

PUHY-P250YJM-A x2

63.0

56.0

54.8

51.5

n/a

refer to databook

refer to databook

refer to databook

refer to databook

170 / 170

n/a

22.2 (7/8”)

9.52 (3/8”)

58 / 58

200 + 200

920 + 920

760

1710

380-415v, 50hz

3

8 / 8

refer to databook

refer to databook

20 / 20

4 + earth

PQHY-P-YHM-A - CONDENSING UNITS

PQHY-P250YHM-A

31.5

28.0

n/a

n/a

n/a

5.51

5.45

n/a

n/a

n/a

n/a

22.2 (7/8”)

9.52 (3/8”)

49

195

880

550

1160

380-415v, 50hz

3

8

8.5

8.4

20

4 + earth

PQHY-P250YHM-A x2

63.0

56.0

n/a

n/a

n/a

5.51 / 5.51

5.45 / 5.45

n/a

n/a

n/a

n/a

22.2 (7/8”)

9.52 (3/8”)

49 / 49

195 + 195

880 + 880

550

1160

380-415v, 50hz

3

8 / 8

8.5 / 8.5

8.4 / 8.4

20 / 20

4 + earth

Page 107: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PLFY-P32, 40, 50, 63, 80, 100, 125VBM-E

MODELS

PlFy-P32-80vbm-e

PlFy-P100-125vbm-e

A

241

281

B

258

298

upper view >

lower view >

side view >

cit

y m

ult

iR

ange

PlF

y-P-v

bm

-e

Dimensions

Page 205

PlFy-P-vbm-e2, 3 and 4-Way Blow Ceiling Cassette Indoor Unit

PLFY-P-VBM-E - INDOOR UNITSmodel reFerence

caPacity (kw) heating (nominal)

cooling (nominal)

hP heating (uK)

coP P heating (uK)

cooling (uK)

high sensible cooling (uK)

shF (uK)

high sensible (uK)

Power inPut (kw) heating (nominal)

cooling (nominal)

airFlow (m3/min) lo-mi1-mi2-hi

noise (dba) lo-mi1-mi2-hi

weight (kg) (grille)

dimensions (mm) width (grille)

depth (grille)

height (grille)

electrical suPPly

Phase

running current (a) heating

cooling

Fuse rating (bs88) - hrc (a)

mains cable no. cores

grille model reFerence

PLFY-P32VBM-E

4.0

3.6

4.0

3.7

3.4

2.6

0.82

0.96

0.02

0.03

11-12-13-14

27-28-29-31

22(6)

840(950)

840(950)

258(35)

220-240v, 50hz

single

0.14

0.22

6

3

PlP-6ba

PLFY-P50VBM-E

6.3

5.6

6.3

5.9

5.3

4.1

0.75

0.83

0.03

0.04

12-13-14-16

27-28-30-31

22(6)

840(950)

840(950)

258(35)

220-240v, 50hz

single

0.22

0.29

6

3

PlP-6ba

PLFY-P80VBM-E

10.0

9.0

10.0

9.4

8.5

6.5

0.72

0.78

0.06

0.07

16-18-20-22

30-32-35-37

23(6)

840(950)

840(950)

258(35)

220-240v, 50hz

single

0.43

0.51

6

3

PlP-6ba

PLFY-P125VBM-E

16.0

14.0

16.0

15.0

13.3

10.2

0.70

0.75

0.15

0.16

22-25-28-30

35-38-41-43

27(6)

840(950)

840(950)

298(35)

220-240v, 50hz

single

1.00

1.07

6

3

PlP-6ba

PLFY-P40VBM-E

5.0

4.5

5.0

4.7

4.3

3.3

0.79

0.91

0.03

0.04

12-13-14-16

27-28-30-31

22(6)

840(950)

840(950)

258(35)

220-240v, 50hz

single

0.22

0.29

6

3

PlP-6ba

PLFY-P63VBM-E

8.0

7.1

8.0

7.5

6.7

5.2

0.73

0.79

0.04

0.05

14-15-16-18

28-29-30-32

23(6)

840(950)

840(950)

258(35)

220-240v, 50hz

single

0.29

0.36

6

3

PlP-6ba

PLFY-P100VBM-E

12.5

11.2

12.5

11.7

10.6

8.1

0.72

0.79

0.14

0.15

21-24-27-29

34-37-39-41

27(6)

840(950)

840(950)

298(35)

220-240v, 50hz

single

0.94

1.00

6

3

PlP-6ba

Technical Information

Power cassettes offer 72 different airflow patterns, with the ability to handle a multitude of ceiling applications up to4.2 metres in height. The easy to install, slim unit is ideal for maintaining constant temperatures, thanks to adjustablevanes that allow users to precisely direct air where it’s needed.

The Mitsubishi Electric airflow control mechanism has been improved and uses wider vanes so that the unit reducesdrafts and smudging, whilst a high performance drain pump on the drain lift mechanism allows drain water to be lifted up to 850mm from the ceiling surface.

� handy corner pocket design simplifies maintenance

� airflow controllable for ceiling heights up to 4.2m, with automatic adjustment of fan speed

� reduced draft air distribution, with independent vane control

� drain pump as standard, 850mm from drain pan

� Filter lowering operation down to 4m (optional PlP-6baJ grille required)

� optional ‘i see sensor’ for energy saving and smooth temperature control throughout the room

� For further information on the features of this cassette,please see page 72

Page 204

Page 108: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PLFY-P20, 25, 32, 40VCM-E2

lower view >

side view >

cit

y m

ult

iR

ange

PlFy

-P-v

cm

-e2

Dimensions

Page 207

PlFy-P-vcm-e2

The compact size of this unit is ideal for 600x600mm ceilings and with a depth of 208mm, this lightweight unit makes installation a breeze. This unit also comes complete with a long life filter that will last for approximately 2,500 hours.

600x600 4-Way Blow Ceiling Cassette Indoor Unit

PLFY-P-VCM-E2 - INDOOR UNITSmodel reFerence

caPacity (kw) heating (nominal)

cooling (nominal)

hP heating (uK)

coP P heating (uK)

cooling (uK)

high sensible cooling (uK)

shF (uK)

high sensible (uK)

Power inPut (kw) heating (nominal)

cooling (nominal)

airFlow (m3/min) lo-mi-hi

noise (dba) lo-mi-hi

weight (kg) (grille)

dimensions (mm) width (grille)

depth (grille)

height (grille)

electrical suPPly

Phase

running current (a) heating

cooling

Fuse rating (bs88) - hrc (a)

mains cable no. cores

grille model reFerence

PLFY-P20VCM-E2

2.5

2.2

2.5

2.3

2.1

1.6

0.86

1.00

0.05

0.05

8-9-10

28-31-35

15.5(3)

570(650)

570(650)

235(20)

220-240v, 50hz

single

0.23

0.23

6

3

slP-2aaw

PLFY-P25VCM-E2

3.2

2.8

3.2

3.0

2.7

2.0

0.78

0.95

0.05

0.05

8-9-10

28-31-37

15.5(3)

570(650)

570(650)

235(20)

220-240v, 50hz

single

0.23

0.23

6

3

slP-2aaw

PLFY-P32VCM-E2

4.0

3.6

4.0

3.7

3.4

2.6

0.76

0.85

0.06

0.06

8-9-11

29-33-38

17(3)

570(650)

570(650)

235(20)

220-240v, 50hz

single

0.28

0.28

6

3

slP-2aaw

PLFY-P40VCM-E2

5.0

4.5

5.0

4.7

4.3

3.3

0.70

0.76

0.06

0.06

8-9-11

30-34-39

17(3)

570(650)

570(650)

235(20)

220-240v, 50hz

single

0.28

0.28

6

3

slP-2aaw

Technical Information

� compact size for handy installation and easy maintenance

� only 208mm high

� Fresh air duct facility

Page 206

Page 109: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PLFY-P20, 25, 32, 40, 50, 63, 80, 100VLMD-E

PLFY-P125VLMD-E

Front view >

lower view >

side view > upper view >

CMP-40VLW-C

CMP-63VLW-C

CMP-100VLW-C

side view >

rear view > lower view >

cit

y m

ult

iR

ange

PlF

y-P-v

lmd

-e

Dimensions

Page 209

PlFy-P-vlmd-e2-Way Blow Ceiling Cassette Indoor Unit

PLFY-P-VLMD-E - INDOOR UNITS

model reFerence

caPacity (kw) heating (nominal)

cooling (nominal)

hP heating (uK)

coP P heating (uK)

cooling (uK)

high sensible cooling (uK)

shF (uK)

high sensible (uK)

Power inPut (kw) heating (nominal)

cooling (nominal)

airFlow (m3/min) lo-mi1-mi2-hi

noise (dba) lo-mi1-mi2-hi

weight (kg) (grille)

dimensions (mm) width (grille)

depth (grille)

height (grille)*1

electrical suPPly

Phase

running current (a) heating

cooling

Fuse rating (bs88) - hrc (a)

mains cable no. cores

grille model reFerence

PLFY-P20VLMD-E

2.5

2.2

2.5

2.3

2.1

1.6

0.90

1.00

0.065

0.072

6.5-8.0-9.5

27-30-33

23(6.5)

776(1080)

634(710)

290(20)

220-240v,

50hz

single

0.30

0.36

6

3

cmP-

40vlw-c

PLFY-P25VLMD-E

3.2

2.8

3.2

3.0

2.7

2.0

0.78

0.90

0.065

0.072

6.5-8.0-9.5

27-30-33

23(6.5)

776(1080)

634(710)

290(20)

220-240v,

50hz

single

0.30

0.36

6

3

cmP-

40vlw-c

PLFY-P32VLMD-E

4.0

3.6

4.0

3.7

3.4

2.6

0.74

0.85

0.065

0.072

6.5-8.0-9.5

27-30-33

24(6.5)

776(1080)

634(710)

290(20)

220-240v,

50hz

single

0.30

0.36

6

3

cmP-

40vlw-c

PLFY-P40VLMD-E

5.0

4.5

5.0

4.7

4.3

3.3

0.70

0.76

0.074

0.081

7.0-8.5-10.5

29-33-36

24(6.5)

776(1080)

634(710)

290(20)

220-240v,

50hz

single

0.34

0.40

6

3

cmP-

40vlw-c

PLFY-P50VLMD-E

6.3

5.6

6.3

5.9

5.3

4.1

0.72

0.78

0.075

0.082

9.0-11.0-12.5

31-34-37

27(7.5)

946(1250)

634(710)

290(20)

220-240v,

50hz

single

0.35

0.41

6

3

cmP-

63vlw-c

PLFY-P63VLMD-E

8.0

7.1

8.0

7.5

6.7

5.2

0.70

0.75

0.094

0.101

10.0-13.0-15.5

32-37-39

28(7.5)

946(1250)

634(710)

290(20)

220-240v,

50hz

single

0.43

0.49

6

3

cmP-

63vlw-c

PLFY-P80VLMD-E

10.0

9.0

10.0

9.4

8.5

6.5

0.73

0.82

0.140

0.147

15.5-18.5-22.0

33-36-39

44(12.5)

1446(1750)

634(710)

290(20)

220-240v,

50hz

single

0.66

0.72

6

3

cmP-

100vlw-c

PLFY-P100VLMD-E

12.5

11.2

12.5

11.7

10.6

8.1

0.73

0.79

0.150

0.157

17.5-21.0-25.0

36-39-42

47(12.5)

1446(1750)

634(710)

290(20)

220-240v,

50hz

single

0.69

0.75

6

3

cmP-

100vlw-c

PLFY-P125VLMD-E

16.0

14.0

16.0

15.0

13.3

10.2

0.73

0.80

0.27

0.28

24-27-30-33

40-42-44-46

56(13)

1708(2010)

606(710)

290(20)

220-240v,

50hz

single

1.33

1.35

6

3

cmP-

125vlw-c

Technical Information

The PLFY-P-VLMD-E cassette unit fits into the space in a suspendedceiling to provide heating or cooling. This new unit has been redesigned with lower unit height and lower noise levels.

� light unit for ease of installation

� terminal block on outside of unit for easy wiring

� drain lift-pump mechanism as standard

� newly designed pure white decoration panel withair flow switching and swing functions as standard

Page 208

*1 Void space required is 350mm or more

upper view >

Page 110: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

lower view >

side view >

upper view >

Front view >

PMFY-P20, 25, 32, 40VBM-E

cit

y m

ult

iR

ange

Pm

Fy-P

-vb

m-e

Dimensions

Page 211

PmFy-P-vbm-e1-Way Blow Ceiling Cassette Indoor Unit

PMFY-P-VBM-E - INDOOR UNITSmodel reFerence

caPacity (kw) heating (nominal)

cooling (nominal)

hP heating (uK)

coP P heating (uK)

cooling (uK)

high sensible cooling (uK)

shF (uK)

high sensible (uK)

Power inPut (kw) heating (nominal)

cooling (nominal)

airFlow (m3/min) lo-mi1-mi2-hi

noise (dba) lo-mi1-mi2-hi

weight (kg) (grille)

dimensions (mm) width (grille)

depth (grille)

height (grille)

electrical suPPly

Phase

running current (a) heating

cooling

Fuse rating (bs88) - hrc (a)

mains cable no. cores

grille model reFerence

PMFY-P20VBM-E

2.5

2.2

2.5

2.3

2.1

1.6

0.86

1.00

0.042

0.042

6.5-7.2-8.0-8.7

27-30-33-35

14(3)

812(1000)

395(470)

230(30)

220-240v, 50hz

single

0.20

0.20

6

3

PmP-40bmw

PMFY-P25VBM-E

3.2

2.8

3.2

3.0

2.7

2.0

0.81

0.95

0.044

0.044

7.3-8.0-8.6-9.3

32-34-36-37

14(3)

812(1000)

395(470)

230(30)

220-240v, 50hz

single

0.21

0.21

6

3

PmP-40bmw

PMFY-P32VBM-E

4.0

3.6

4.0

3.7

3.4

2.6

0.76

0.85

0.044

0.044

7.3-8.0-8.6-9.3

32-34-36-37

14(3)

812(1000)

395(470)

230(30)

220-240v, 50hz

single

0.21

0.21

6

3

PmP-40bmw

PMFY-P40VBM-E

5.0

4.5

5.0

4.7

4.3

3.3

0.72

0.82

0.054

0.054

7.7-8.7-9.7-10.7

33-35-37-39

14(3)

812(1000)

395(470)

230(30)

220-240v, 50hz

single

0.26

0.26

6

3

PmP-40bmw

Technical Information

Utilising a compact and lightweight body, the unit is perfect for applications where ceiling space is limited. A total body weight of 14kg makes it one of the lightest available, latest fan technology also makes it one of the quietest.

� compact size for handy installation and easy maintenance

� newly developed airflow control technology reduces noise levels to only 27dba

� drain lift pump mechanism allows the drain to be positioned anywhere up to 600mm from the ceiling’s surface

� only 230mm high

� Fresh air duct facility

� Pure white grille

Page 210

Page 111: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PEFY-P15, 20, 25, 32, 40, 50, 63 VMS1-E

a bPeFy-P15-32vms1-e 700 752

PeFy-P40-50vms1-e 900 952

c798

998

d660

860

e7

9

F600

800

PeFy-P63vms1-e 1100 1152 1198 1060 11 1000

model

side view >

Front view >

upper view >

cit

y m

ult

iR

ange

PeF

y-P-v

ms1

-e

Dimensions

Page 213

PeFy-P-vms1-eUltra Thin Ceiling Concealed Ducted Indoor Unit

The ultra thin ceiling concealed ducted indoor unit offers increased flexibility and is particularlysuitable for places where low noise operation is desired from a slimline body.

� ultra thin body - height of only 200mm & width of only 790mm (P15-32)

� extremely quiet operation - as low as 22dba

� cooling operation set temperature can be set down to 14°c db

� static pressure of 5-50Pa

� now available in a size 15, ideal for hotel rooms

PEFY-P-VMS1-E - INDOOR UNITS

model reFerence

caPacity (kw) heating (nominal)

cooling (nominal)

hP heating (uK)

coP P heating (uK)

cooling (uK)

high sensible cooling (uK)

shF (uK)

high sensible (uK)

Power inPut (kw) heating (nominal)

cooling (nominal)

airFlow (m3/min) lo-mi-hi

external static Pressure (Pa) lo-mi1-mi2-hi

noise (dba) (15Pa) lo-mi-hi

weight (kg)

dimensions (mm) width

depth

height

electrical suPPly

Phase

running current (a) heating

cooling

Fuse rating (bs88) - hrc (a)

mains cable no. cores

PEFY-P15VMS1-E

1.9

1.7

1.9

1.8

1.6

1.2

0.94

1.00

0.03

0.05

5.0-6.0-7.0

5-15-35-50

22-24-28

19

790

700

200

220-240v, 50hz

single

0.31

0.42

6

3

PEFY-P25VMS1-E

3.2

2.8

3.2

3.0

2.7

2.0

0.78

0.90

0.04

0.06

5.5-7.0-9.0

5-15-35-50

24-26-30

19

790

700

200

220-240v, 50hz

single

0.39

0.50

6

3

PEFY-P40VMS1-E

5.0

4.5

5.0

4.7

4.3

3.3

0.72

0.82

0.05

0.07

8.0-9.5-11.0

5-15-35-50

28-30-33

24

990

700

200

220-240v, 50hz

single

0.45

0.56

6

3

PEFY-P63VMS1-E

8.0

7.1

8.0

7.5

6.7

5.2

0.73

0.79

0.07

0.09

12.0-14.0-16.5

5-15-35-50

30-33-36

28

1190

700

200

220-240v, 50hz

single

0.61

0.72

6

3

PEFY-P20VMS1-E

2.5

2.2

2.5

2.3

2.1

1.6

0.86

1.00

0.03

0.05

5.5-6.5-8.0

5-15-35-50

22-25-29

19

790

700

200

220-240v, 50hz

single

0.36

0.47

6

3

PEFY-P32VMS1-E

4.0

3.6

4.0

3.7

3.4

2.6

0.76

0.85

0.05

0.07

6.0-8.0-10.0

5-15-35-50

24-27-32

20

790

700

200

220-240v, 50hz

single

0.39

0.50

6

3

PEFY-P50VMS1-E

6.3

5.6

6.3

5.9

5.3

4.1

0.72

0.78

0.07

0.09

9.5-11.0-13.0

5-15-35-50

30-32-35

24

990

700

200

220-240v, 50hz

single

0.56

0.67

6

3

Technical Information

Page 212

Page 112: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PEFY-P20, 25, 32, 40, 50, 63, 80, 100, 125VMA-E

side view >

upper view >

Front view >

cit

y m

ult

iR

ange

PeF

y-P-v

ma

-e

Dimensions

Page 215

rear view >

a bPeFy-P20-32vma-e 700 754

PeFy-P40-50vma-e 900 954

PeFy-P63-80vma-e 1100 1154

c800

1000

1200

d660

860

1060

e7

9

11

PeFy-P100-125vma-e 1400 1454 1500 1360 14

F600

800

1000

g658

858

1058

1300 1358

model

PeFy-P-vma-eCeiling Concealed Ducted Indoor Unit

PEFY-P-VMA-E - INDOOR UNITSmodel reFerence

caPacity (kw) heating (nominal)

cooling (nominal)

hP heating (uK)

coP P heating (uK)

cooling (uK)

high sensible cooling (uK)

shF (uK)

high sensible (uK)

Power inPut (kw) heating (nominal)

cooling (nominal)

airFlow (m3/min) lo-mi-hi

external static Pressure (Pa) - lo-mi1-mi2-mi3-hi

noise (dba) (50Pa) lo-mi-hi

weight (kg)

dimensions (mm) width

depth

height

electrical suPPly

Phase

running current (a) heating

cooling

Fuse rating (bs88) - hrc (a)

mains cable no. cores

PEFY-P20VMA-E

2.5

2.2

2.5

2.3

2.1

1.6

0.90

1.00

0.04

0.06

6.0-7.5-8.5

35-50-70-100-150

23-25-26

23

700

732

250

220-240v,

50hz

single

0.42

0.53

6

3

PEFY-P25VMA-E

3.2

2.8

3.2

3.0

2.7

2.0

0.78

0.90

0.04

0.06

6.0-7.5-8.5

35-50-70-100-150

23-25-26

23

700

732

250

220-240v,

50hz

single

0.42

0.53

6

3

PEFY-P32VMA-E

4.0

3.6

4.0

3.7

3.4

2.6

0.74

0.85

0.05

0.07

7.5-9.0-10.5

35-50-70-100-150

23-26-29

23

700

732

250

220-240v,

50hz

single

0.44

0.55

6

3

PEFY-P40VMA-E

5.0

4.5

5.0

4.7

4.3

3.3

0.79

0.91

0.07

0.09

10-12-14

35-50-70-100-150

23-27-30

26

900

732

250

220-240v,

50hz

single

0.53

0.64

6

3

PEFY-P50VMA-E

6.3

5.6

6.3

5.9

5.3

4.1

0.79

0.88

0.09

0.11

12.0-14.5-17.0

35-50-70-100-150

25-29-32

26

900

732

250

220-240v,

50hz

single

0.63

0.74

6

3

PEFY-P63VMA-E

8.0

7.1

8.0

7.5

6.7

5.2

0.78

0.87

0.10

0.12

13.5-16.0-19.0

35-50-70-100-150

25-29-33

32

1100

732

250

220-240v,

50hz

single

0.90

1.01

6

3

PEFY-P80VMA-E

10.0

9.0

10.0

9.4

8.5

6.5

0.72

0.78

0.12

0.14

14.5-18.0-21.0

35-50-70-100-150

26-29-34

32

1100

732

250

220-240v,

50hz

single

1.04

1.15

6

3

PEFY-P100VMA-E

12.5

11.2

12.5

11.7

10.6

8.1

0.79

0.89

0.22

0.24

23-28-33

35-50-70-100-150

28-33-37

42

1400

732

250

220-240v,

50hz

single

1.36

1.47

6

3

PEFY-P125VMA-E

16.0

14.0

16.0

15.0

13.3

10.2

0.77

0.86

0.32

0.34

28-34-40

35-50-70-100-150

32-36-40

42

1400

732

250

220-240v,

50hz

single

1.94

2.05

6

3

Technical Information

The PEFY-P-VMA-E ducted indoor unit is concealed within the ceiling space to allow unobtrusive air conditioning. Flexibility of duct layout allows air flow patterns to be arranged to suit any application.

� reduced height - now only 250mm

� wider range of external static pressure settings across entire range

� reduced noise levels thanks to the use of a newly designed centrifugal fan- as low as 23dba

� cooling operation set temperature can be set down to 14ºc db

� drain pump included as standard

Page 214

Page 113: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PEFY-P80, 100, 125, 140VMH-E

PEFY-P250VMH-E

side view >upper view >

side view >upper view >

cit

y m

ult

iR

ange

PeF

y-P-v

mh

-e

Dimensions

Page 217

PeFy-P-vmh-eHigh Static Pressure Ceiling Concealed Ducted Indoor Unit

PEFY-P-VMH-E - INDOOR UNITS

model reFerence

caPacity (kw) heating (nominal)

cooling (nominal)

hP heating (uK)

coP P heating (uK)

cooling (uK)

high sensible cooling (uK)

shF (uK)

high sensible (uK)

Power inPut (kw) heating (nominal)

cooling (nominal)

airFlow (m3/min) lo-hi

external static Pressure (Pa) - lo-mi-hi

noise (dba) (150Pa) lo-hi

weight (kg)

dimensions (mm) width

depth

height

electrical suPPly

Phase

running current (a) heating

cooling

Fuse rating (bs88) - hrc (a)

mains cable no. cores

PEFY-P80VMH-E

10.0

9.0

10.0

9.4

8.5

6.5

0.74

0.83

0.32

0.32

18-25

100-150-200

38-43

50

1000

900

380

220-240v, 50hz

single

1.47

1.47

6

3

PEFY-P100VMH-E

12.5

11.2

12.5

11.7

10.6

8.1

0.80

0.91

0.48

0.48

26.5-38.0

100-150-200

38-44

70

1200

900

380

220-240v, 50hz

single

2.34

2.34

6

3

PEFY-P125VMH-E

16.0

14.0

16.0

15.0

13.3

10.2

0.74

0.81

0.48

0.48

26.5-38.0

100-150-200

38-44

70

1200

900

380

220-240v, 50hz

single

2.34

2.34

6

3

PEFY-P140VMH-E

18.0

16.0

18.0

16.8

15.2

11.6

0.74

0.82

0.48

0.48

28-40

100-150-200

38-44

70

1200

900

380

220-240v, 50hz

single

2.35

2.35

6

3

PEFY-P250VMH-E

31.5

28.0

31.5

29.5

26.5

20.3

0.75

0.84

1.23

1.23

72

130-260

52 (130Pa)

100

1250

1120

470

380-415v, 50hz

3

2.0

2.0

6

5

Technical Information

With improved design flexibility as a result of increased externalstatic pressure, the PEFY-P-VMH-E allows authentic duct airconditioning within the strictest aesthetic confines.

� external static pressure of up to 260Pa

� greater flexibility for duct extension,branching air outlet configuration

� reduced noise levels thanks to the useof newly designed centrifugal fan

� duct can be connected to intake side

� drain lift-pump (option) 550mm of lift

� cooling operation set temperature can be set down to 14ºc db

Page 216

Page 114: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

84

88

195 230

57

254

476

680

182 85 878

960 2 2 853 5

10 51

236

PCFY-P40VKM-E

8488

195 230

5725

447

668

0

182 851198

1280 221173 5

1051

236

PCFY-P63VKM-E

510

51

236

8488

195 230

5725

447

668

0

182 851518

1600 221493

PCFY-P100, 125VKM-E

lower view >

side view >Front view >

cit

y m

ult

iR

ange

Pc

Fy-P

-vK

m-e

Dimensions

Page 219

lower view >

side view >Front view >

lower view >

side view >Front view >

PcFy-P-vKm-eCeiling Suspended Indoor Unit

PCFY-P-VKM-E - INDOOR UNITSmodel reFerence

caPacity (kw) heating (nominal)

cooling (nominal)

hP heating (uK)

coP P heating (uK)

cooling (uK)

high sensible cooling (uK)

shF (uK)

high sensible (uK)

Power inPut (kw) heating (nominal)

cooling (nominal)

airFlow (m3/min) lo-mi1-mi2-hi

noise (dba) lo-mi1-mi2-hi

weight (kg)

dimensions (mm) width

depth

height

electrical suPPly

Phase

running current (a) heating

cooling

Fuse rating (bs88) - hrc (a)

mains cable no. cores

PCFY-P40VKM-E

5.0

4.5

5.0

4.7

4.3

3.3

0.72

0.79

0.04

0.04

10-11-12-13

29-32-34-36

24

960

680

230

220-240v, 50hz

single

0.28

0.28

6

3

PCFY-P63VKM-E

8.0

7.1

8.0

7.5

6.7

5.2

0.72

0.77

0.05

0.05

14-15-16-18

31-33-35-37

32

1280

680

230

220-240v, 50hz

single

0.33

0.33

6

3

PCFY-P100VKM-E

12.5

11.2

12.5

11.7

10.6

8.1

0.70

0.75

0.09

0.09

21-24-26-28

36-38-41-43

36

1600

680

230

220-240v, 50hz

single

0.65

0.65

6

3

PCFY-P125VKM-E

16.0

14.0

16.0

15.0

13.3

10.2

0.69

0.75

0.11

0.11

21-24-27-31

36-39-42-44

38

1600

680

230

220-240v, 50hz

single

0.76

0.76

6

3

Technical Information

Designed for ultra-quiet operation and easy maintenance, the unit provides comfortable air conditioning for a wide range of applications where floor or wall space cannot be used practically.

� indoor unit designed for direct ceiling suspension

� Flush to wall installation for concealment of service connections

� drain piping can be connected from left or right

Page 218

Page 115: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

1170

365

74 (855) 241 5295

249 5155688

898

55

295

PKFY-P15, 20, 25VBM-E

PKFY-P32, 40, 50VHM-E

right side view >Front view >

right side view >Front view >

PKFY-P63VKM-E

right side view >Front view >

cit

y m

ult

iR

ange

PKFy

-P-v

bm

-e / P

KFy

-P-v

hm

-e / P

KFy

-P-v

Km

-e

Dimensions

Page 221

PKFy-P-vbm-e/vhm-e/vKm-eWall Mounted Indoor Units

PKFY-P-VBM-E / VHM-E / VKM-E - INDOOR UNITSmodel reFerence

caPacity (kw) heating (nominal)

cooling (nominal)

hP heating (uK)

coP P heating (uK)

cooling (uK)

high sensible cooling (uK)

shF (uK)

high sensible (uK)

Power inPut (kw) heating (nominal)

cooling (nominal)

airFlow (m3/min) lo-mi1-mi2-hi

noise (dba) lo-mi1-mi2-hi

weight (kg)

dimensions (mm) width

depth

height

electrical suPPly

Phase

running current (a) heating

cooling

Fuse rating (bs88) - hrc (a)

mains cable no. cores

PKFY-P15VBM-E

1.9

1.7

1.9

1.8

1.6

1.2

0.75

0.83

0.04

0.04

4.9-5.0-5.2-5.3

29-31-32-33

10

815

225

295

220-240v, 50hz

single

0.20

0.20

6

3

Technical Information

An elegant design combined with compact dimensions and quiet operationmake the PKFY-P an ideal unit choice. Noise levels are significantly reducedthanks to a unique airflow passage design that not only makes the unit one of the quietest in the industry, but also suppresses condensation and prevents mixing with secondary air.

� compact flat panel design - only 815mm wide (vbm-e)

� Front grille opening for easy cleaning

� Front power supply for easy wiring after installation

� 5-way piping provides more flexibility in selection of installation sites

Page 220

PKFY-P20VBM-E

2.5

2.2

2.5

2.3

2.1

1.6

0.71

0.75

0.04

0.04

4.9-5.2-5.6-5.9

29-31-34-36

10

815

225

295

220-240v, 50hz

single

0.20

0.20

6

3

PKFY-P25VBM-E

3.2

2.8

3.2

3.0

2.7

2.0

0.70

0.80

0.04

0.04

4.9-5.2-5.6-5.9

29-31-34-36

10

815

225

295

220-240v, 50hz

single

0.20

0.20

6

3

PKFY-P32VHM-E

4.0

3.6

4.0

3.7

3.4

2.6

0.76

0.85

0.03

0.04

9-10-11

34-37-41

13

898

249

295

220-240v, 50hz

single

0.30

0.40

6

3

PKFY-P40VHM-E

5.0

4.5

5.0

4.7

4.3

3.3

0.74

0.82

0.03

0.04

9-10.5-11.5

34-38-41

13

898

249

295

220-240v, 50hz

single

0.30

0.40

6

3

PKFY-P63VKM-E

8.0

7.1

8.0

7.5

6.7

5.2

0.78

0.85

0.04

0.05

16-20

39-45

21

1170

295

365

220-240v, 50hz

single

0.30

0.37

6

3

PKFY-P50VHM-E

6.3

5.6

6.3

5.9

5.3

4.1

0.72

0.78

0.03

0.04

9-10.5-12

34-39-43

13

898

249

295

220-240v, 50hz

single

0.30

0.40

6

3

Page 116: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PFFY-P20, 25, 32, 40, 50, 63VLRM-E

side view >

upper view >

Front view > cit

y m

ult

iR

ange

PFF

y-P-v

lrm

-e

Dimensions

Page 223

PFFy-P-vlrm-eFloor Standing Concealed Indoor Unit

PFFY-P-VLRM-E - INDOOR UNITSmodel reFerence

caPacity (kw) heating (nominal)

cooling (nominal)

hP heating (uK)

coP P heating (uK)

cooling (uK)

high sensible cooling (uK)

shF (uK)

high sensible (uK)

Power inPut (kw) heating (nominal)

cooling (nominal)

airFlow (m3/min) lo-hi

noise (dba) lo-hi

weight (kg)

dimensions (mm) width

depth

height

electrical suPPly

Phase

running current (a) heating

cooling

Fuse rating (bs88) - hrc (a)

mains cable no. cores

PFFY-P20VLRM-E

2.5

2.2

2.5

2.3

2.1

1.6

0.81

0.88

0.04

0.04

5.5-6.5

34-40

18.5

886

220

639

220-240v, 50hz

single

0.19

0.19

6

3

PFFY-P25VLRM-E

3.2

2.8

3.2

3.0

2.7

2.0

0.70

0.80

0.04

0.04

5.5-6.5

34-40

18.5

886

220

639

220-240v, 50hz

single

0.19

0.19

6

3

PFFY-P32VLRM-E

4.0

3.6

4.0

3.7

3.4

2.6

0.74

0.81

0.06

0.06

7-9

35-40

20

1006

220

639

220-240v, 50hz

single

0.29

0.29

6

3

PFFY-P40VLRM-E

5.0

4.5

5.0

4.7

4.3

3.3

0.72

0.79

0.065

0.065

9-11

38-43

21

1006

220

639

220-240v, 50hz

single

0.32

0.32

6

3

PFFY-P50VLRM-E

6.3

5.6

6.3

5.9

5.3

4.1

0.74

0.80

0.085

0.085

12-14

38-43

25

1246

220

639

220-240v, 50hz

single

0.40

0.40

6

3

PFFY-P63VLRM-E

8.0

7.1

8.0

7.5

6.7

5.2

0.73

0.79

0.10

0.10

12-15.5

40-46

27

1246

220

639

220-240v, 50hz

single

0.46

0.46

6

3

A compact concealed unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install and at only 220mmdeep offers an unobtrusive method of delivering highly efficient air-conditioning performance.

� concealed unit for hidden installation

� ideal for perimeter refurbishments

� cooling operation set temperaturecan be set down to 14ºc db

Technical Information

Page 222

Page 117: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PFFY-P20, 25, 32, 40, 50, 63VLRMM-E

side view >

upper view >

Front view >

cit

y m

ult

iR

ange

PFF

y-P-v

lrm

m-e

Dimensions

Page 225

PFFy-P-vlrmm-eFloor Standing Concealed Indoor Unit

A compact concealed unit providing simple, effective air conditioningin perimeter zones. The unit is easy to install and at only 220mmdeep offers an unobtrusive method of delivering highly efficient air-conditioning performance.

PFFY-P-VLRMM-E - INDOOR UNITS

model reFerence

caPacity (kw) heating (nominal)

cooling (nominal)

hP heating (uK)

coP P heating (uK)

cooling (uK)

high sensible cooling (uK)

shF (uK)

high sensible (uK)

Power inPut (kw) heating (nominal)

cooling (nominal)

airFlow (m3/min) lo-mi-hi

external static Pressure (Pa) lo-mi-hi

noise (dba) (20Pa) lo-mi-hi

weight (kg)

dimensions (mm) width

depth

height

electrical suPPly

Phase

running current (a) heating

cooling

Fuse rating (bs88) - hrc (a)

mains cable no. cores

PFFY-P20VLRMM-E

2.5

2.2

2.5

2.3

2.1

1.6

0.81

0.88

0.04

0.04

4.5-5.5-6.5

20-40-60

31-36-40

18.5

886

220

639

220-240v, 50hz

single

0.34

0.34

6

3

PFFY-P32VLRMM-E

4.0

3.6

4.0

3.7

3.4

2.6

0.74

0.81

0.04

0.04

6.5-7.5-9

20-40-60

27-32-37

20

1006

220

639

220-240v, 50hz

single

0.38

0.38

6

3

PFFY-P50VLRMM-E

6.3

5.6

6.3

5.9

5.3

4.1

0.74

0.80

0.05

0.05

10-12-14

20-40-60

32-37-41

25

1246

220

639

220-240v, 50hz

single

0.48

0.48

6

3

PFFY-P25VLRMM-E

3.2

2.8

3.2

3.0

2.7

2.0

0.70

0.80

0.04

0.04

4.5-5.5-6.5

20-40-60

31-36-40

18.5

886

220

639

220-240v, 50hz

single

0.34

0.34

6

3

PFFY-P40VLRMM-E

5.0

4.5

5.0

4.7

4.3

3.3

0.72

0.79

0.05

0.05

8-9.5-11

20-40-60

30-36-40

21

1006

220

639

220-240v, 50hz

single

0.43

0.43

6

3

PFFY-P63VLRMM-E

8.0

7.1

8.0

7.5

6.7

5.2

0.73

0.79

0.07

0.07

11-13-15.5

20-40-60

35-40-44

27

1246

220

639

220-240v, 50hz

single

0.59

0.59

6

3

Technical Information

Page 224

� reduced noise levels compared to the PFFy-P-vlrm-e version

� cooling operation set temperature can be set down to 14ºc db

� static pressure. the new unit has 3 static pressure settings- 20/40/60Pa ideal for ducting in the perimeter zone

� concealed unit for hidden installation. the unit can be hidden behind a wardrobe in a hotel, then ducted above and below the wardrobe doors. this offerslower noise, less disruption and a low visual impact

Page 118: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PFFY-P20,25,32,40,50,63VLEM-E

side view >

upper view >

Front view >

cit

y m

ult

iR

ange

PFF

y-P-v

lem

-e

Dimensions

Page 227

PFFy-P-vlem-eFloor Standing Exposed Indoor Unit

PFFY-P-VLEM-E - INDOOR UNITSmodel reFerence

caPacity (kw) heating (nominal)

cooling (nominal)

hP heating (uK)

coP P heating (uK)

cooling (uK)

high sensible cooling (uK)

shF (uK)

high sensible (uK)

Power inPut (kw) heating (nominal)

cooling (nominal)

airFlow (m3/min) lo-hi

noise (dba) lo-hi

weight (kg)

dimensions (mm) width

depth

height

electrical suPPly

Phase

running current (a) heating

cooling

Fuse rating (bs88) - hrc (a)

mains cable no. cores

PFFY-P20VLEM-E

2.5

2.2

2.5

2.3

2.1

1.6

0.81

0.88

0.04

0.04

5.5-6.5

34-40

23

1050

220

630

220-240v, 50hz

single

0.19

0.19

6

3

PFFY-P25VLEM-E

3.2

2.8

3.2

3.0

2.7

2.0

0.70

0.80

0.04

0.04

5.5-6.5

34-40

23

1050

220

630

220-240v, 50hz

single

0.19

0.19

6

3

PFFY-P32VLEM-E

4.0

3.6

4.0

3.7

3.4

2.6

0.74

0.81

0.06

0.06

7-9

35-40

25

1170

220

630

220-240v, 50hz

single

0.29

0.29

6

3

PFFY-P40VLEM-E

5.0

4.5

5.0

4.7

4.3

3.3

0.72

0.79

0.065

0.065

9-11

38-43

26

1170

220

630

220-240v, 50hz

single

0.32

0.32

6

3

PFFY-P50VLEM-E

6.3

5.6

6.3

5.9

5.3

4.1

0.74

0.80

0.085

0.085

12-14

38-43

30

1410

220

630

220-240v, 50hz

single

0.40

0.40

6

3

PFFY-P63VLEM-E

8.0

7.1

8.0

7.5

6.7

5.2

0.73

0.79

0.10

0.10

12-15.5

40-46

32

1410

220

630

220-240v, 50hz

single

0.46

0.46

6

3

A compact cased unit providing simple, effective air conditioning in perimeter zones. The unit is easy to install, and at only 220mmdeep offers an unobtrusive method of delivering a highly efficient air-conditioning performance.

� remote controller can be incorporated into the main unit

� cooling operation set temperature can be set down to 14ºc db

Technical Information

Page 226

Page 119: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PFFY-P20,25,32,40VKM-E

Front view >

upper view >

side view >

cit

y m

ult

iR

ange

PFF

y-P-v

Km

-e

Dimensions

Page 229

PFFy-P-vKm-eFloor Standing Exposed Indoor Unit

PFFY-P-VKM-E - INDOOR UNITSmodel reFerence

caPacity (kw) heating (nominal)

cooling (nominal)

hP heating (uK)

coP P heating (uK)

cooling (uK)

high sensible cooling (uK)

shF (uK)

high sensible (uK)

Power inPut (kw) heating (nominal)

cooling (nominal)

airFlow (m3/min) lo-mi1-mi2-hi

noise (dba) lo-mi1-mi2-hi

weight (kg)

dimensions (mm) width

depth

height

electrical suPPly

Phase

running current (a) heating

cooling

Fuse rating (bs88) - hrc (a)

mains cable no. cores

PFFY-P20VKM-E

2.5

2.2

2.5

2.3

2.1

1.6

0.81

0.88

0.025

0.025

5.9-6.8-7.6-8.7

27-31-34-37

15

700

200

600

220-240v, 50hz

single

0.20

0.20

6

3

PFFY-P25VKM-E

3.2

2.8

3.2

3.0

2.7

2.0

0.74

0.85

0.025

0.025

6.1-7.0-8.0-9.1

28-32-35-38

15

700

200

600

220-240v, 50hz

single

0.20

0.20

6

3

PFFY-P32VKM-E

4.0

3.6

4.0

3.7

3.4

2.6

0.71

0.77

0.025

0.025

6.1-7.0-8.0-9.1

28-32-35-38

15

700

200

600

220-240v, 50hz

single

0.20

0.20

6

3

PFFY-P40VKM-E

5.0

4.5

5.0

4.7

4.3

3.3

0.70

0.76

0.028

0.028

8.0-9.0-9.5-10.7

35-38-42-44

15

700

200

600

220-240v, 50hz

single

0.24

0.24

6

3

The PFFY-P-VKM-E series is extremely versatile and is designed for wall attached installation at floor level. The auto swing vane provides a more natural and comfortable airflow throughout the room and the lightweight, compact design makes installation easy.

� Pure white, slimline design

� upper and lower vanes for optimum, powerful and efficient air distribution

Technical Information

Page 228

Page 120: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

GUF-50/100RD3

side view >

upper view >

Front view >

cit

y m

ult

iR

ange

gu

F-r

d3

Dimensions

Page 231

OUTDOOR AIR PROCESSING INDOOR UNITSmodel reFerence

caPacity (kw) heating (nominal)

cooling (nominal)

hP heating (uK)

coP P heating (uK)

cooling (uK)

Power inPut (kw)

airFlow (m3/h) lo-hi

external static Pressure (Pa)

noise (dba) lo-hi

weight (kg)

dimensions (mm) width

depth

height

electrical suPPly

Phase

running current (a) lo-hi

Fuse rating (bs88) - hrc (a)

mains cable no. cores

GUF-50RD3

6.42 (2.25)

5.29 (1.66)

6.42 (2.25)

5.93 (2.08)

5.03 (1.58)

0.265

400-500

140

33.5-34.5

54

1016

1288

317

220-240v, 50hz

single

0.70-1.15

6

3

GUF-100RD3

13.00 (4.70)

10.81 (3.49)

13.00 (4.70)

12.01 (4.34)

10.27 (3.32)

0.505

800-1000

140

38-39

92

1231

1580

398

220-240v, 50hz

single

1.73-2.20

6

3

guF-rd3Lossnay Outdoor Air Processing Indoor Unit

1. nominal condition: Cooling/Heating capacity indicates the value of operation under the following air condition and above air volume.Cooling: Indoor 27ºC DB/19.5ºC WB, Outdoor 35ºC DB/24ºC WB.Heating: Indoor 21ºC DB/14.6ºC WB, Outdoor 7ºC DB/6ºC WB.

2. uK condition:Summer: Indoor 21ºC, Outdoor 27ºCWinter : Indoor 21ºC, Outdoor -1ºCWB

3. The figures in ( ) indicates the heat recovery at Lossnay core.

4. The current, input and efficiency are based on the above air volume.

5. The air nozzle noise (45º angle 1.5m ahead) is about 6dB greater than the indicated value. (High notch).

6. Specifications may be subject to change without notice.

The GUF-50RD3 and GUF-100RD3 outdoor air processing units can be used with any of the extensive range of City Multi indoor units to provide ventilation, dust removal, humidification and heat recovery.

� a combination of a lossnay & city multi indoor in a single unit

� air temperature in any room can be adjusted to the desired temperature via this unit which is used as an indoor unit of the city multi air conditioning system

� the ventilating and air conditioning functions are integrated in a single unit, saving space and installation costs

� heat recovery helps to save energy - a benefit that’s not only good for the environment, but also great for cutting energy costs

� Free cooling is also available should outdoor conditions be suitable

Technical Information

Page 230

attention

Page 121: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

)wercs 1R( niarD

xob lortnoC

teltuo retaW)wercs 4/3CR(

lenap ecivreS

tinu roodtuo fo epip noitcennoC )diuqiL(

ø >dezarB< 88.51

ø dezarB< 25.9 >

tinu roodtuo fo epip noitcennoC)saG(

telni retaW)wercs 4/3R(

525)hctip gnitnuoM(

(Mou

ntin

g pi

tch)

205

800

300

054

005

55

53

53

19

19431

480

64

6014

0

100

191

8016

5

102

54

481

411

PWFY-P100VM-E-BU

PWFY-P100/200VM-E-AU

upper view >

side view >Front view >

tnioj noisnapxE eht esU:002Pseirossecca fo

)wercs 1R( niarD

ø >dezarB< 25.9

teltuo retaW)wercs 4/3CR(

telni retaW)wercs 4/3R(

:001P ø >dezarB< 88.51:002P ø dezarB< 50.91 >

tinu roodtuo fo epip noitcennoC )saG(

tinu roodtuo fo epip noitcennoC )diuqiL(

xob lortnoC

lenap ecivreS

525( hctip gnitnuoM )

054

(Mou

ntin

g pi

tch)

300

800

205

005

19

19

53

55

53

480

102

602

431

411

100

191

64

60140

8016

5

54

cit

y m

ult

iR

ange

Pw

Fy-P

Dimensions

Page 233

upper view >

side view >Front view >

PwFy-PVRF Heat Pump Boiler

Technical Information

Page 232

PWFY-P

model reFerence

caPacity heating (nominal)

cooling (nominal)

heating (uK)

Power inPut (kw)

comPatible outdoor / condensing units

reFrigerant charge (kg) high temp circuit

PiPe siZe (mm) (in) gas

liquid

water

drain

noise (dba)

weight (kg)

dimensions (mm) width

depth

height

electrical suPPly

Phase

running current (a)

Fuse rating (bs88) - hrc (a)

mains cable no. cores

water Flow rate m3/h

PWFY-P100VM-E-BU

12.5

-

12.5

2.48

Pury / PQry

1.1 (r134a)

15.88 (5/8")

9.52 (3/8")

19.05 (3/4”)

ø32 (1 1/4”)

44

60

450

300

785 (800)

220-240v, 50hz

single

10.66

25

3

0.6-2.15

PWFY-P200VM-E-AU

25.0

22.4

20.8

0.015

Puhy / PQhy / Pury / PQry

-

19.05 (3/4")

9.52 (3/8")

19.05 (3/4”)

ø32 (1 1/4”)

29

38

450

300

785 (800)

220-240v, 50hz

single

0.063

6

3

1.2-4.3

PWFY-P100VM-E-AU

12.5

11.2

10.4

0.015

Puhy / PQhy / Pury / PQry

-

15.88 (5/8")

9.52 (3/8")

19.05 (3/4”)

ø32 (1 1/4”)

29

35

450

300

785 (800)

220-240v, 50hz

single

0.063

6

3

0.6-2.15

the mitsubishi electric booster unit (PwFy-P100vm-e-bu) can achieve a flow temperature of 70ºC and is anideal solution for providing a hot water supply to commercial buildings in an energy efficient manner.

Heat pump technology works by extracting heat from the air and upgrading it to heat a building. This process in itself is energy efficient, howeverwe can take this a step further by using heat recovery. Heat recovery technology taps into and utilises otherwise wasted heat energy, extractedfrom areas of a building that require cooling, providing heating for hot water almost for free. Recovering the heat in this manner maximisesthe efficiency of the system all year round, therefore increasing energy savings and lowering running costs.

Taking full advantage of heat recovery technology, the 12.5kW PWFY booster unit upgrades the heat pump energy to higher temperaturesrequired to achieve 70ºC water temperatures. This is possible using the first ever VRF cascade refrigeration system between R410A andR134a refrigerant.

The benefit of having air conditioning as well as a hot water supply from a single system means that the unit is suitable for a variety of applications. Offices, hotels, gyms, restaurants etc are typical examples of buildings that already have an air conditioning system in place. Providing the essential hot water supply to these applications is a simple addition of the booster unit to the existing air conditioning system. It is a perfect solution that allows inconveniences that arise when installing gas boilers such as gas grid connection costs, meter installation and maintenance costs to be eliminated. Further there is a reduction in running costs and carbon emissions due to the high efficiency of these units over gas boilers.

The Mitsubishi Electric air to water heating units (PWFY-P100/200VM-E-AU) can achieve flow temperatures of 45ºC in heating and 10ºC in cooling, making them perfect forapplication on underfloor heating/cooling systems.

� can be used in conjunction with cmb-Pw202v-J to allow a 200% heat recovery index� uses the Par-w21maa controller

note: The PWFY-P200VM-E-AU will require 2 expansion joints

Page 122: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

cit

y m

ult

iR

ange

vr

F Ph

v d

xe

Hea

t Pu

mp

Air

Cur

tain

Page 235

AIR CURTAIN vrF Phv1000/1500/2000r dxe

Dimensions

AIR CURTAIN vrF Phv1000/1500/2000 dxe

rear view >

upper view >

side view >

rear view >

upper view >

side view >

vrF Phv dxe Heat Pump Air CurtainAir Curtain System

Page 234

VRF PHV DXE - RECESSEDmodel reFerence

dimensions (mm) (wxdxh)

suPPly (50hz)

heat outPut (kw)

loading (amps)

velocity (m/s)

air volume (m3/h)

weight (kg)

noise db(a) @ 3m

max. mounting height (m)

outdoor unit model

VRF PHV1500R DXE HO

1650x436x296

415v*1

15.1

12.7*1

9

2600

67

58

3.5

Pumy / Puhy / Pury / PQhy / PQry

VRF PHV2000R DXE LO

2240x436x296

415v*2

16.4

15.7*2

9.5

3300

85

59

3.5

Pumy / Puhy / Pury / PQhy / PQry

Technical Information

VRF PHV DXE - FREE STANDINGmodel reFerence

dimensions (mm) (wxdxh)

suPPly (50hz)

heat outPut (kw)

loading (amps)

velocity (m/s)

air volume (m3/h)

weight (kg)

noise db(a) @ 3m

max. mounting height (m)

outdoor unit model

VRF PHV1500R DXE LO

1650x436x296

415v*1

10.6

12.7*1

9

2500

66

58

3.5

Pumy / Puhy / Pury / PQhy / PQry

VRF PHV1000R DXE HO

1150x436x296

415v*1

9

7.8*1

9

1400

45

56

3.5

Pumy / Puhy / Pury / PQhy / PQry

VRF PHV2000R DXE HO

2240x436x296

415v*2

21.4

15.7*2

9

3130

88

59

3.5

Puhy / Pury / PQhy / PQry

VRF PHV1500 DXE HO

1746x377x255

415v*1

15.1

12.7*1

9

2600

60

58

3.75

Pumy / Puhy / Pury / PQhy / PQry

VRF PHV2000 DXE LO

2296x377x255

415v*2

16.4

15.7*2

9.5

3300

78

59

3.75

Pumy / Puhy / Pury / PQhy / PQry

VRF PHV1500 DXE LO

1746x377x255

415v*1

10.6

12.7*1

9

2500

59

58

3.75

Pumy / Puhy / Pury / PQhy / PQry

VRF PHV1000 DXE HO

1196x377x255

415v*1

9

7.8*1

9

1400

39

56

3.75

Pumy / Puhy / Pury / PQhy / PQry

VRF PHV2000 DXE HO

2296x377x255

415v*2

21.4

15.7*2

9

3130

80

59

3.75

Puhy / Pury / PQhy / PQry

notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for VRF PHV1000R DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.

notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for VRF PHV1000 DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.

In collaboration with Thermoscreens®, Mitsubishi Electric have developed a range of air curtains that are able to beconnected to our City Multi VRF systems, as opposed to the more traditional direct electric method associatedwith air curtains.

� reduced co2 emissions

� reduced running costs

� inverter technology (does not waste energy)

� range of different sizes to suit every application

� allows open door policy in retail outletswhilst being energy efficient

� clean environment - protection from dust, fumes etc

� comfortable climate for customers

� easy to install and maintain

� heat recovery possible, optimising energy use

Page 123: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

INDOOR UNIT vrF Phv2000 nt

Dimensions

vr

F Ph

v n

tSe

nsib

le C

oolin

g C

hille

d W

ater

Uni

t

rear view >

upper view >

Page 237

side view >

upper view >

vrF Phv ntSensible Cooling, Chilled Water Wall Mounted Indoor Unit

In collaboration with Thermoscreens®, Mitsubishi Electric have developed a sensible cooling wall mounted unit that can be connected to our City Multi VRF systems via the PWFY-P200VM-E-AU heat pump boiler. This unit offers 100% sensible cooling (SHF of 1) for use in server rooms and other sensible cooling applications.

� shF of 1 and capacity validated by 3rd party assessment (bsria)

� reduced co2 emissions

� reduced running costs

� inverter technology (does not waste energy)

� easy to install and maintain

� ideal for small to medium size server rooms / laboratories

� no 3rd party humidifier is required

� Par-w21maa controller included

� ideal for heat recovery applications - use with the water system connection box (wcb)

on page 240 to achieve full heat recovery potential

Page 236

Technical Information

VRF PHV NT - indoor units

model reFerence

dimensions (mm) width

depth

height

caPacity (kw) cooling

shF

electrical suPPly

Phase

loading (a)

velocity (m/s)

air volume (m3/h)

weight (kg)

noise (dba) @ 3m

water volume Flow rate (m3/h)

hydraulic resistance (kPa @ 3.18 m3/h)

hydraulic resistance oF PwFy-P200vm-e-au (kPa @ 3.18 m3/h)

water volume oF coil (litres)

water volume oF heat exchanger in PwFy-P200vm-e-au (litres)

outdoor unit model

VRF PHV2000 NT

2296

377

255

12.0

1.0

220-240v, 50hz

single

2.7

9

2885

90

59

3.18

36

38*1

5.1

2.09

Puhy / Pury / PQhy / PQry

notes: For use with a Mitsubishi Electric PWFY-P200VM-E-AU water cooling unit as part of a VRF system. Water flow temperature from the PWFY-P is to be set to 10ºC (cannot be set lower)Test conditions: 35ºC DB / 27ºC WB outdoor conditions, 24ºC DB / 40% relative humidity indoor conditions - validated by BSRIA tests. *1 Without strainer.

C. 1

50m

in.

for p

ipes

255

295

168

36

cit

y m

ult

iR

ange

PwFy-P (not included)

Page 124: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

CMB-P104, 105, 106V-G1

CMB-P108, 1010, 1013, 1016V-GA1/HA1

CMB-P104, 108V-GB1

side view >upper view >

CMB-P1016V-HB1

a bcmb-P104v-gb1

cmb-P108v-gb1

3

7

180

420

cit

y m

ult

iR

ange

bc

cont

rolle

rs

Dimensions

side view >upper view >

side view >upper view >

side view >upper view >

Page 239

cmb-P104v-g1

cmb-P105v-g1

a b

3

4

180

240

cmb-P106v-g1 5 300

a b

cmb-P108v-ga1

cmb-P1010v-ga1

7

9

420

540

cmb-P1013v-ga1 12 720

cmb-P1016v-ga1/ha1 15 900

bc controllers

BC CONTROLLERSmodel reFerence

number oF connections

weight (kg)

dimensions (mm) width

depth

height

electrical suPPly

Phase

Power inPut (Kw)

running current (a)

Fuse rating (bs88) – hrc (a)

mains cable no. cores

CMB-P104V-G1

4

24

648

432

284

220-240v, 50hz

single

0.085

0.36

6

3

CMB-P106V-G1

6

28

648

432

284

220-240v, 50hz

single

0.123

0.52

6

3

CMB-P105V-G1

5

27

648

432

284

220-240v, 50hz

single

0.104

0.44

6

3

Technical Information

At the heart of both the R2 and WR2 Series, the BC controller makessimultaneous heating and cooling possible. It has the inherent ‘intelligence’ to be the system’s decision-maker.

� transferring energy around the system

� drawing on energy from the heat source units/outdoor units

� directing energy as requested by the individual indoor units

� instructs the heat source unit/outdoor unit on the amount of refrigerant (liquid or gas) that is required to achieve the requested cooling or heating requirements

� allows unique 2-pipe heatrecovery application

� hic circuit for improved efficiency

� new brazed connections

note: CMB-P-V-G1 units are for use with PURY-(E)P200-350 YJM-A & PQRY-P200-300YHM-A units only.

SLAVE BC CONTROLLERSmodel reFerence

number oF connections

weight (kg)

dimensions (mm) width

depth

height

electrical suPPly

Phase

Power inPut (Kw)

running current (a)

Fuse rating (bs88) – hrc (a)

mains cable no. cores

CMB-P104V-GB1

4

22

648

432

284

220-240v, 50hz

single

0.076

0.32

6

3

CMB-P1016V-HB1

16

55

1098

432

284

220-240v, 50hz

single

0.301

1.26

6

3

CMB-P108V-GB1

8

32

648

432

284

220-240v, 50hz

single

0.151

0.63

6

3

MASTER BC CONTROLLERSmodel reFerence

number oF connections

weight (kg)

dimensions (mm) width

depth

height

electrical suPPly

Phase

Power inPut (Kw)

running current (a)

Fuse rating (bs88) – hrc (a)

mains cable no. cores

CMB-P108V-GA1

8

43

1110

520

289

220-240v, 50hz

single

0.161

0.68

6

3

CMB-P1013V-GA1

13

55

1110

520

289

220-240v, 50hz

single

0.255

1.07

6

3

CMB-P1016V-HA1

16

69

1110

520

289

220-240v, 50hz

single

0.312

1.30

6

3

CMB-P1010V-GA1

10

48

1110

520

289

220-240v, 50hz

single

0.198

0.83

6

3

CMB-P1016V-GA1

16

62

1110

520

289

220-240v, 50hz

single

0.312

1.30

6

3

Page 238

note: CMB-P-V-GA1 units are for use with PURY-(E)P200-650Y(S)JM-A(1) & PQRY-P200-600Y(S)HM-A units only. CMB-P1016V-HA1 unit is for use with PURY-(E)P700-900YSJM-A units only.

Page 125: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

CMB-PW202V-J

side view >

upper view >

cit

y m

ult

iR

ange

wat

er c

onn

ection

box

(wc

b)

Dimensions

Front view >

Page 241

water system connection box (wcb)

WCBmodel reFerence

comPatible outdoor / condensing units

weight (kg)

dimensions (mm) width

depth

height

electrical suPPly

Phase

Power inPut (Kw)

running current (a)

Fuse rating (bs88) – hrc (a)

mains cable no. cores

CMB-PW202V-J

Pury-(e)P200-350yJm-a / PQry-P200-300yhm-a

20

648

432

284

220-240v, 50hz

single

0.024

0.10

6

3

Technical Information

By utilising a WCB, a system can be sized for the cooling load of a communications room and then use the delivery of cold waterfrom a PWFY to achieve this. The system can then benefit from full heat recovery of up to 200% by connecting a second PWFY inheating mode that can deliver sanitary hot water or hot water for space heating elsewhere in the building.

Typically the outdoor unit of a system is sized to match the internal load. For a communications room there is a continuous coolingload and under normal circumstances all the heat is wasted to the outside.

Following the success of PWFY, this new low cost branch controller allows simple heat recovery between 2 ports, onebeing heating only with PWFY, the other being heating or cooling with PWFY or standard indoor units. A key factorwith the WCB is the ability to allow 200% connectable index to the system.

� total heat recovery, transferring all energy around the system

� 200% connectable heat recovery index for optimum efficiency, flexibility andcost savings (130% when connecting with standard indoor units)

� energy saving mode available (longer heat up time, but with a15% coP improvement on standard control)

� installation cost and time savings

� connectable to both bu and au PwFy models

Page 240

example 2: 130% connection with hot water and cooling/heating indoor units

outdoor heat recovery unit (size 200)

wcb

PwFy-P200au (heating)to underfloor heating

example 1: 200% connection with continual heating only and cooling only Ports

PwFy-P200au (cooling)to third party comms room unit

PwFy-P100bu (hot water) to tank

3 x PeFy-P50vma(cooling/heating)restaurant

outdoor heat recovery unit (size 200)

wcb

note: 100% if only in heating

Page 126: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

cit

y m

ult

iR

ange

air

han

dlin

g u

nit

cont

rolle

rs /

acc

esso

ries

accessories / optional extras

CMY-Y102S-G2CMY-Y102L-G2CMY-Y202-G2CMY-Y302-G2CMY-Y62-G-ECMY-Y100VBK2

CMY-Y200VBK2CMY-Y300VBK2CMY-RP100VBKCMY-RP200VBKCMY-R100VBKCMY-R200VBKCMY-R100XLVBKCMY-R200XLVBKCMY-Q100VBKACH1ACH2PAC-CN32WHMC-UK

PLP-6BASLP-2AAWPLP-6BALMPLP-6BAJPAC-SA1ME-EPAR-SA9FA-ES70E40714

CMP-40VLW-CCMP-63VLW-CCMP-100VLW-CCMP-125VLW-CPAC-KH11OF

PMP-40BMW

PAC-KE04DM-FPAC-KE88LAFPAC-KE89LAFPAC-KE85LAFPAC-KE80TB-FPAC-KE140TB-FPAC-KE250TB-F

CMY-R160-J1CMY-S202-J

PAC-SE41TS-E

PAR-W21MAATHERM-10M

outdoor units

4-way blow cassette units

2-way blow cassette units

1-way blow cassette units

ceiling concealed ducted units

bc controllers

indoor units

vrF heat Pump boilers

A range of Acoustic Kits designed for noise reduction. An industry first, the kits offer a 8dBA noise level reduction from standard.

For supply and / or installation please contact

ambient acoustics on 01934 712802

acoustic Kits for PUHY and PURY Series units

- Branch Pipe (Joint) for size 200 or below - total capacity of indoor units- Branch Pipe (Joint) for size 201-400 - total capacity of indoor units- Branch Pipe (Joint) for size 401-650 - total capacity of indoor units or first branch of (E)P450-P650- Branch Pipe (Joint) for size 651 or above - total capacity of indoor units or first branch of P700-P1250 / EP700-EP900- Branch Pipe for 2 branches (PUMY)- Twinning Kit for PUHY-P500-650YSJM-A / PUHY-EP400-600YSJM-A /

PUHY-HP400-500YSHM-A / PQHY-P400-600YSHM-A- Twinning Kit for PUHY-P700-900YSJM-A- Twinning Kit for PUHY-P950-1250YSJM-A / PUHY-EP650-900YSJM-A / PQHY-P650-900YSHM-A- Twinning Kit for PUHY-RP400-650YSJM-B- Twinning Kit for PUHY-RP700-900YSJM-B- Twinning Kit for PURY-P450-650YSJM-A(1) / PURY-EP400-600YSJM-A- Twinning Kit for PURY-P700-800YSJM-A- Twinning Kit for PURY-EP650-700YSJM-A- Twinning Kit for PURY-P850-900YSJM-A- Twinning Kit for PQRY-P400-600YSHM-A- PQFY Auto-Changeover controller- VRF AHU Interface (for use with 24v AC signals)- Energy monitoring connector

- Grille for PLFY-P-VBM-E- Grille for PLFY-P-VCM-E2- Grille and infra-red controller for PLFY-P-VBM-E- Grille with filter lowering function for PLFY-P-VBM-E- ‘I -See Sensor’ corner panel for PLFY-P-VBM-E- Infra-red signal receiver for PLFY-P-VBM-E- Infra-red Controller (PAR-SL97A-E) for PLFY-P-VBM-E

- Grille for PLFY-P20-40VLMD-E- Grille for PLFY-P50-63VLMD-E- Grille for PLFY-P80-100VLMD-E- Grille for PLFY-P125VLMD-E- OA duct flange for PLFY-P20-100VLMD-E

- Grille for PMFY-P-VBM-E

- Drain lift-up mechanism for PEFY-P-VMH-E- Long life filter for PEFY-P80VMH-E- Long life filter for PEFY-P100-140VMH-E- Long life filter for PEFY-P250VMH-E- Filter box for PEFY-P80VMH-E (necessary when long life filter is used)- Filter box for PEFY-P100-140VMH-E (necessary when long life filter is used)- Filter box for PEFY-P250VMH-E (necessary when long life filter is used)

- Joint pipe- Cover cap for CMB-PW202V-J

- Remote sensor

- Controller- Thermistor (10m cable)

Air Handling Unit Controller

PAC-AH-M-J - AHU CONTROLLERmodel reFerence

air handling unit siZe

allowed heat exchanger caPacity (kw) - heating

allowed heat exchanger caPacity (kw) - cooling

allowed heat exchanger volume (cm3)

reFerence air Flow rate (m3/h)*3

standard evaPorator Path number*1

dimensions (mm) width

( ) = inc mountings depth

height

weight (kg)

PiPe siZe mm(in) gas

liquid

aPPlicable outdoor units

Puhy-P y(s)Jm-a

Puhy-eP y(s)Jm-a

Puhy-hP y(s)Hm-a

Puhy-rP y(s)Jm-b

PQhy-P y(s)Hm-a

PAC-AH125M-J

P100

10.0 - 12.5

9.0 - 11.2

1500 - 2850

2000

4 - 5

328

104 (122)

378 (420)

5

15.88(5/8”)

9.52(3/8”)

PAC-AH125M-J

P125

12.5 - 16.0

11.2 - 14.0

1900 - 3550

2500

4 - 5

328

104 (122)

378 (420)

5

15.88(5/8”)

9.52(3/8”)

PAC-AH140M-J

P140

16.0 - 18.0

14.0 - 16.0

2150 - 4050

3000

5 - 6

328

104 (122)

378 (420)

5

15.88(5/8”)

9.52(3/8”)

PAC-AH250M-J

P200

18.0 - 25.0

16.0 - 22.4

3000 - 5700

4000

6 - 10

328

104 (122)

378 (420)

5

19.05(3/4”)

9.52(3/8”)

PAC-AH250M-J

P250

25.0 - 31.5

22.4 - 28.0

3750 - 7100

5000

8 - 10

328

104 (122)

378 (420)

5

22.22(7/8”)

9.52(3/8”)

PAC-AH500M-J

P400*2

40.0 - 50.0

36.0 - 45.0

6000 - 11400

8000

16 - 20

328

104 (122)

378 (420)

5

28.58(1 1/8”)

12.7(1/2”)

PAC-AH500M-J

P500*2

50.0 - 63.0

45.0 - 56.0

7500 - 14200

10000

16 - 20

328

104 (122)

378 (420)

5

28.58(1 1/8”)

15.88(5/8”)

note: One air handling unit controller is required per air handling unit. Saturated refrigerant temperature at exit of evaporator = 8.5ºC, SH = 5K, liquid temperature = 25ºC, air = 27ºCDB/19ºCWB*1 When the diameter of the heat exchanger tube is ø9.52. *2 P400 and P500 are not compatible with PURY and PQRY. *3 If using in combination with standard indoor units, then these figures do not apply.

m-net wiring thermistor wiring

Piping

air handling unit (field supplied)

controller (field supplied)

outdoor unit (mitsubishi electric)

Technical Information

The Air Handling Unit Controller is an interface to allow connection to third party manufacturer equipment.

Mitsubishi Electric City Multi outdoor units can be used with thisinterface box, creating and ideal solution when a unique air handlingunit is required. The Air Handling Unit Controllers are supplied withLEV expansion device(s).

� discharge or return air temperature control

� temperature set point by control 0-10vdc� auto mode available for ease of application� error input� iP2x rated (only for internal use)

air handling unit controller (mitsubishi electric)

220-240v, 50hz Power supply

Pac-ah-m-J

example:

Pury-P y(s)Jm-a

Pury-eP y(s)Jm-a

Pury-rP yJm-b

PQry-P y(s)Hm-a

Page 243Page 242

Page 127: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Lossnay Total Heat Exchangers

Air Conditioning Commercial Heating

Domestic Heating Photovoltaics

Page 128: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

The secret of the Lossnay system liesin the cross flow, plate fin structure of the heat exchange unit.A diaphragm made of specially processed paper fully separatesinlet and exhaust air supplies, ensuring that only fresh air isintroduced to the indoor environment.

The microscopically small pores of the diaphragm havebeen made even smaller, decreasing the rate at which watersoluble gases such as Ammonia and Hydrogen pass through.Further, a new specially processed paper used to make thediaphragm has been developed with high moisture permeabilitycharacteristics.

This aids in the transfer of moisture and improves theeffectiveness of shielding unwanted gases, resulting in highly efficient energy transfer.

Improvements to the Lossnay

Fresh airinto building

(Supply Air)

Stale airremoved from

building (Return Air)

Stale dirty indoor air (Exhaust Air)

Fresh air introduction(Outdoor Air)

Outdoors Indoors

Fresh air supply to the room

Stale room air extracted

Stale exhaust air

Fresh air from outside

Heat exchange unit(Lossnay core)

Page 247

Poor air quality can be attributed to many problems arising in theworkplace or in the home. It is believed to contribute to a significantloss in productivity, low morale and higher rates of sickness amongstmany employees. The object of providing good ventilation alongsideair conditioning in residential and commercial buildings is to provideconditions under which people can live and work in comfort and safety.

Developed and refined over the past 35 years, the Lossnay system hasperfected the recovery of energy that would have otherwise been wasted. The units reduce overall energy costs by extracting stale air and then recoveringthe heating or cooling energy to either warm or cool incoming fresh air.By utilising this energy, the Lossnay system can save up to 30% on initial capital costsof heating and cooling plant by reducing the load of the occupied space, resulting inthe need for a smaller heating and/or cooling system.

Page 246

TheSecret of

the LossnaySystemExcellent Air Quality

and Unbeatable HeatExchange Efficiency

Simple andEffective

Page 129: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Using a Lossnay LGH-100RX5 in the winter example above, 8.2kW of heat is recovered per hour from the extracted air.

Effective VentilationLossnay’s simultaneous air exhaust/supply provides effectiveventilation. Conventional ventilators (i.e. extract propeller fans)do not work effectively within air tight buildings because of thenegative air pressures involved.

Good Energy RecoveryTotal heat (sensible and latent) recovery provides acomfortable air temperature within the room. The energysaved by using Lossnay contributes towards lowering theheating or cooling requirement within the building, therefore reducing the energy requirement and running costs.

Free Cooling “By-pass”Function (LGH series)When the outdoor temperature is lower than the indoor air conditioned temperature in the summer, Lossnay providesfresh outdoor cool air to reduce the indoor air temperature.

Good Sound AttenuationAs the Lossnay core is made of paper and the permeable holesare small, the Lossnay core provides outstanding soundproofingproperties and is appropriate for sound proof rooms.

Part L2 BuildingRegulationsWith the introduction of Part L2 (Part J in Scotland), newbuilding design is changing to become more airtight, as well asenergy efficient. The need for fresh air has remained the samehowever and thus poses new challenges for modern design.Lossnay fully meets these challenges due to its basic principaland its efficient heat recovery.

Page 249

Main Features ofLossnay

Page 248

Total HeatRecoveryConcept

Operationin winter

4°CStale warm air (exhaust)

0°CFresh cool air (outdoor air)

20°CStale warm air

(indoor air)

16°CFresh warm air

(indoor supply air)

Heating unit

Operationin summer

25.6°CStale cool air (exhaust)

27°CFresh hot air (outdoor air)

21°CStale cool air (indoor air)

22.4°CFresh cool air

(indoor supply air)

Coolingunit

Page 130: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Ambient Temperature - London 2006, 8am - 6pm

Over 58% of the time between 8am-6pm,the temperature in London was between8ºC and 20ºC, allowing free cooling when the air conditioning setpoint was 21ºC incooling mode. If the setpoint is higher, free cooling is increased.

Lossnay fan speed button is incorporated within the standard PAR-30MAA and PAR-F27MEA controllers

Above example:

One LGH25RX5 serving one PLA-RP71BA. Room size 7m x 7m,140w/m2 heat load. 7 people per room, 10litres/person of fresh air to meet Part F requirements. Maximum amount of fresh air to be introduced is 30% of the fan coil volume. Ceiling cassettes may require fresh air casements. Free cooling is not available below 8ºC when interlocked with Mr Slim or City Multi units.

Lossnay units can work either on their own to provide fresh air into a room, or in combinationwith Mr Slim or City Multi ceiling cassettes and ducted units.

When working together with air conditioning, Lossnay units can provide significant energy savings by automatically utilising free cooling as well as heat recovery. As the Lossnay and the air conditioning unit are connected by a two core communication cable, they can worktogether to optimise both comfort and energy efficiency. This is done by the Lossnay reading the mode and set temperature the air conditioning requires, then utilising the outside temperature to help achieve the required temperature either by free cooling or heat recovery.

When using Lossnay in conjunction with air conditioning the heating and cooling loads can be reduced significantly, reducing therunning costs by up to 30% compared with air conditioning systems without heat recovery systems.

The graph shows the hourly temperature for 2006 in London between 8.00am - 6.00p.m. The point tonote is the amount of free cooling available duringthese hours, as well as the heat recovery below (22% of the time) and cooling recovery above (20% of the time). Lossnay is a year round solution for providing fresh air.

Page 251

Lossnay Working in Conjunctionwith Air Conditioning

Page 250

Free Cooling was available in

London over 58%of the time in

2006

Page 131: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Multi-Ventilation ModeEnables the appropriate supply/exhaust balance to be selected to suit usage,environment and location.

All LGH-RX5-E models feature the "Multi-ventilation Mode,"which allows the air supply/exhaust balance to be varieddynamically to suit the usage environment and location.Modes can be selected easily by setting the connectorson the circuit board.

* "High" can be further set to "Extra high" using the dip switch.

Normal Office Small Office or Building Industrial Areas

Power air supply& air exhaust

Most widely-used pattern formingthe basis for traditional ventilationdesign. This allows the most efficientventilation while maintaining the airsupply/exhaust balance. The optimumventilation rate can be maintained byselecting the Power air supply/exhaustmode with both the air supply & air exhaust switched to "High" (or "Extra high") on the main unit. For example in an office, the controlswitches can be set to "High" to runin Power air supply/exhaust modewhen a large number of people are in the office, then switched to "Low"to run in Energy-saving ventilationmode late at night or on holidayswhen there are few people present.

In smaller offices or buildings, theremay be insufficient air supply to themain rooms or offices due to theexcessive exhaust via extractor fanslocated in toilets or kitchen areas.Setting to Power air supply mode with the air supply switch on "High" (or "Extra high") and the air exhaust switch on "Low" on the main unit, allows efficient ventilation while making up for the insufficient air supply.

In locations such as industrial working areas, dirty air must beexhausted swiftly. Setting the Power air exhaust mode with the air supply switch on "Low" and the air exhaust switch on "High" (or "Extra high") on the main unitallows efficient extraction of fumesand odours. Maintaining the area at a negative air pressure alsoprevents dirty air from spreading to surrounding areas.

Power air supply Power air exhaust

Power air supply/exhaust mode

Power air supply mode

Power air exhaust mode

Energy-saving ventilation mode

Ventilation Mode

High

High

Low

Low

SupplyAirflow

High

Low

High

Low

Exhaust Airflow

Hyper Eco CoreLGH-RX5-E and LGH-RSDC-E Lossnay units feature the newly developed “Hyper Eco Core”, which uses non-porous, ultra-thin film toachieve high enthalpy exchange efficiency. With a thickness of only 25µm, these are the thinnest in the world and are approximately one fifth the thickness of previous Mitsubishi Electric products. Moisture permeability is dramatically increased and enthalpy heatexchange greatly improved.

Consists of a two-layer constructionusing a specially processed materialmade of a preferential permeable film on a porous base material. This provides moisture permeabilityand air barrier properties, but the two-layer construction makes a certain thickness unavoidable.

Consists of a specially processedstructure based on a single-layer, non-porous, ultra-thin film material.Moisture exchange (water vapourtransmission) is promoted by thespecial film, which increases theaffinity for moisture (the thinner the film, the higher the permeability).The non-porous ultra-thin filmmaterial acts as a barrier against air leakage.

Use

Hyper Eco Core material

Previous Mitsubishi Electric material

Photocopier paper

Dictionary paper

The thinnest paper used in regularprinting is 51µm thick (used in dictionaries) and the material of theHyper Eco Core is approximately half the thickness of this.

Comparison of material used in Hyper Eco Core (25µm ultra-thin film) with regular paper

Comparison of new and old Lossnay Core cross-sections

Previous Lossnay Core New Hyper Eco Core

Porous partition plate Non-porous film partition plate

120µm 25µm

Ducts can be connected in two different directions to the outdoor ventsthanks to collars and aperture plates that can be interchangeably placed intwo different positions.

This flexibility allows for installations close to the surface of a wall and helps avoid cases where the stale air exhaust vent would be blocked by an obstruction of some kind. This makes both the planning andinstallation of Lossnay units that much simpler.

Standard installationInstallation with duct

direction changed

A space is necessary to prevent the influx of rainwater.

Collar Aper ture Plate Exchangeable

Can beinstalled closeto the surfaceof the wall.

Changing the duct direction

Connect Ducts in Two DifferentDirections (Outdoor vents)

In addition to the conventional fan speeds, an ExtraLow mode has been added to provide a moredynamic range of air volume settings. This providesversatility in a variety of installation environments,yielding better energy conservation.

Extra Low mode (LGH-RX5-E)CO2 Sensor

Thickness

25µm

120µm

100µm

51µm

Lossnay systems allow you to measureCO2 density (via an independent, 3rd par tyCO2 sensor) and thereby control theamount of fresh air supplied to a building. By connecting a CO2 sensor to the Lossnayunit, the system will switch fan speedsautomatically depending on the CO2 level.

Page 253Page 252

Providing efficient ventilation whilemaintaining air supply/exhaust balance...

Using Lossnay compensates for usingextractor fans...

Priority on air exhaust...

Page 132: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Many office buildings today are heavily insulated, air-tight structureswith little or no natural ventilation. The unnatural environmentcreated by air conditioners without added ventilation is a breedingground for bacteria. Factor this in with the accumulation ofpollutants and odours in the form of formaldehyde, pollen, dust,carbon dioxide and the necessity of ventilation becomes evermore apparent. In fact, poorly ventilated buildings can give rise toSick Building Syndrome, a malady that is known to cause headaches,sore eyes, itching and loss of concentration.

This results not only in discomfort at best and sickness at worst for the building's occupants, but also the reducedproductivity of the workforce. Fresh air, effectively ventilatedthroughout the building is therefore essential to the overall qualityof working life.

Off icesFresh air - improving the overallquality of working life

Restaurants Schools

The atmosphere of a restaurant is crucial to securing andretaining customers. Cleanliness is the key to an attractiveatmosphere and restaurants devote significant effort to ensuringtheir premises are as such. Sanitation and cleanliness, however,are not enough. No matter how clean a restaurant may look, ifthere are bothersome odours lingering in the air, all those effortsgo to waste and the restaurant's clean image is tarnished.

For these reasons, Lossnay’s superior ventilation capabilitiesensure that every breath is a fresh one and a pleasantenvironment is maintained for guests at all times. Lossnay also keeps owners happy with its remarkable heat recoverytechnology that supplies fresh outdoor air with minimal change to indoor temperature, saving on energy costs.

A restaurant can never be tooclean and its air never too fresh

Creating the best possible environmentfor our children to succeed

Children deserve all the help we can give them to grow up healthy, happy and prosperous. No matter how good aschool's curriculum, no matter how positive and enthusiastic theteacher, a child who does not feel well will have a hard time learning. A constant flow of fresh air is nowhere as important as it is in our schools. In classrooms where largenumbers of students are gathered for long periods of time, carbonic gases have the tendency to accumulate,decreasing the levels of oxygen that are vital for alertness and concentration.

This is especially true during the winter months when windowstend to remain closed. Lossnay ventilates fresh outdoor air intoclassrooms to replenish the supply of oxygen and expels notonly carbon dioxide, but also other pollutants and odours thatinevitably sully the air.

Lossnay works to remove stale air and supplyfresh, clean air free of the odours associated

with cooking, cigarettes and the people working and dining.

Change in room temperature is kept to a minimum during ventilation thanks to the

heat-recovery function.

The Lossnay operate very quietly, so those inthe midst of enjoying their meals will not be

bothered by any excess noise.

A large array of Lossnay sizes are available tomatch the layout of just about any restaurant.

The continuous influx of fresh, outdoor air andthe exhaust of stale, indoor air ensure that theindoor oxygen level is maintained at just the

right balance for comfort and health.

Occupants have the luxury of breathing freshair at all times, even in highly air-tight buildings.

Lossnay's sound attenuation qualities preventoutside noise from penetrating into the room,

helping to maintain a quiet environment forproductive study.

Heat-exchange technology prevents fluctuationsin temperature creating significant energy

savings when either heating or cooling a room.

If it’s Lossnay If it’s Lossnay

%3.25

Others: no response

Promotion of waste prevention: 5.4%

Improvement in atmosphere: 6.5%

Reduction of time required forfood to reach the table: 12.0%

Improvement in employees attitude towards customers: 20.5%

Improvement in overallcleanliness

1996 Foodstuffs Consumption Monitor, Second Periodic Survey ( Ministry of Agriculture, Forestry and Fisheries, Japan)

What would you most like to see improved in restaurants?

Incr

ease

d re

spir

atio

nan

d pu

lse

21

15

10

5

0 Nor

mal

air

Safe

ty m

inim

um

O2

Con

cent

ratio

n (%

)

Diz

zine

ss, n

ause

a,lo

ss o

f mus

cle

stre

ngth

(pr

ecur

sors

of d

eath

)

Pale

ness

of s

kin,

vom

iting

,U

ncon

scio

usne

ss

Com

atos

is(d

eath

in 8

min

)

Con

vulsi

ons,

resp

iratio

nst

ops,

deat

h

21 %18 %

16 %

12 %10 %

8 %

6 %

O2 Concentration and Deficiency

2

Page 255Page 254

Occupants havethe luxury of

breathing fresh air at all times, even in

highly air-tight buildings

Simultaneous forced-air supply and exhaust introduces fresh, outdoor air into the building,effectively ventilating even fully airtight structures.

Multiple split-type units operate independently of one another, simplifying system set up and

ensuring a layout that optimally matches nearly any office design.

Lossnay operation can be interlocked withair-conditioning system operation.

Heat that is commonly lost due to ventilation is collected and reused thanks to the

Lossnay Core, reducing an air conditioners energy load and cutting operating costs.

If it’s Lossnay

Page 133: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

The Unbeatable

LossnayThe Lossnay allows the extraction ofstale air and efficient recovery of heating or cooling energy to treat incomingfresh air. Whatever your environment,it’s simple to improve it with Lossnay.

Page 256

Total Heat Exchangers Residential Model

LGH-RSDC-E DC Lossnay Model

LGH-RX5-E Commercial Series

258

260

262

Page 257

Simple technologyat its best

Many of our systems are registered on the Energy Technology Listand hence qualify for 100% first year enhanced capital allowances.

Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB.UK Conditions: Winter ; indoor 21˚C DB; outdoor -1˚C WB.

For further information please go to www.eca.gov.uk

Contents

Page 134: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

VL 100U

Tota

l Hea

t Exch

ange

rsR

esid

entia

l Mod

elLo

ssnay

Ran

ge

Dimensions

Page 259

Residential Model

Total Heat Exchangers

LOSSNAYMODEL REFERENCE

ELECTRICAL POWER SUPPLY

PHASE

POWER CONSUMPTION (W) Low

High

AIRFLOW (m3/h) Low

High

NOISE (dBA) Low

High

Low

High

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

DUCT SIZE (mm)

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

RESIDENTIAL WALL- MOUNTED VL 100U

220-240V, 50Hz

Single

23

26

65

105

29.5

39

77

70

6.5

620

168

265

2xØ75

6

3

TEMPERATURE

EXCHANGE

EFFICIENCY (%)

Technical Information

Particularly suitable for modern homes with high insulation afforded by double glazing and cavity insulation, which require ventilation to remove stale air without major heat loss.

� Effective fresh air ventilation

� Efficient recovery of heating/cooling energy

� Good sound attenuation

� Reduces heating costs

Page 258

Page 135: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

LGH-50RSDC-E

LG

H-5

0R

SDC

-ED

C L

ossn

ay M

odel

Lo

ssnay

Ran

ge

Dimensions

Page 261

Front View >

Upper View >

Rear View >

Left Side View > Right Side View >

Lossnay-5-FSC Interface

� Control up to 16 DC Lossnay units

� Automatic fan speed control based on CO2 level (5 speeds)

� Interlock with a PIR sensor or switch

� Interlock with a CO2 sensor or BEMS (0-10v DC)

� Dimensions (WxDxH) mm: 160x80x120

DC Lossnay Model

LGH-RSDC-E

LOSSNAYMODEL REFERENCE

ELECTRICAL POWER SUPPLY

STARTING CURRENT (A)

VENTILATION MODE

FAN SPEED

INPUT POWER (W)

AIRFLOW (m3/h)

AIRFLOW (l/s)

EXTERNAL STATIC PRESSURE (Pa)

NOISE (dBA)

TEMPERATURE EXCHANGE EFFICIENCY (%)

Heating

Cooling

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

DUCT SIZE (mm)

FUSE RATING (BS88) - HRC (A)

MAINS CABLE No. Cores

LGH-50RSDC-E

220-240V, 50Hz

2

LOSSNAY BYPASS

1

172

445

124

75

31

75

68.5

65.5

2

92

340

94

45

26

80

73.5

71

3

42

240

67

25

21

84.5

78

76

4

23

160

44

10

18

87.5

81.5

79.5

5

14

100

28

5

18

90

83.5

82.5

POWER

279

520

144

102

35

-

-

-

45

1099 + 73

898

302

200

6

3

1

172

445

124

75

31

-

-

-

2

92

340

94

45

26

-

-

-

3

42

240

67

25

21

-

-

-

4

22

160

44

10

18

-

-

-

5

14

100

28

5

18

-

-

-

Technical Information

Particularly suitable for modern homes with high insulation afforded by double glazing and cavity insulation, which require ventilation to remove stale air without major heat loss. This model is also suitable for a number of non-residential applications such as schools.

� Effective fresh air ventilation

� Efficient recovery of heating/cooling energy

� Good sound attenuation

� Reduces heating costs

� Low power consumption with 5 variable fan speeds

� New “Hyper Eco Core” facilitating improved humidity penetration

� By-pass mode for ‘free cooling’. Including new power mode to supply a greater volume of fresh, cool air - for instance during summer nights

� SAP Appendix Q eligible

� Optimise the fan speed based on CO2 level using the Lossnay-5-FSC interface

Page 260

ENTHALPY

EXCHANGE

EFFICIENCY

Page 136: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

LOSSNAY core

Air exhaust fan

Position where duct direction change is possible

By-pass damper plate

Maintenance cover

Control box

Air supply fan

Ceiling suspension fixture

B

150

~250

More

than 6

00

High efficiency filter(sold separately)attachment position

A

change is possible

C

Air filters (EU-G3)

D

E

cable opening

Core, air filter, High-Efficiency filter, fan,Maintenance space

(4-13x20 oval)

EA (exhaust air outlet)

(outside air intake)OA

(return air)RA

(supply air)SA

Power supply

Position where duct direction

Inspection opening

MODEL REFERENCE

LGH-150RX5-E

LGH-200RX5-E

A

1004

1231

B

690

917

C

1045

1272

LGH-15RX5-E to LGH-200RX5-E

Lossnay Controller PZ-60DR-E

A

780

780

888

888

908

1144

1144

B

735

735

874

1016

954

1004

1231

C

273

273

315

315

386

399

399

D

768

768

875

875

895

1010

1010

E

782

782

921

1063

1001

1036

1263

E

Ø100

Ø150

Ø150

Ø200

Ø200

Ø250

Ø250

DIMENSIONS CEILING SUSPENSION FIXTURE PITCH

LGH-15-100RX5-E > LGH-150-200RX5-E >

LOSSNAY core

Maintenance cover

Control box

Air supply fan

cable opening

Air exhaust fanCeiling suspension fixture

By-pass damper plate

High efficiency filter(sold separately)attachment position

Air filters(EU-G3)

Power supply

(supply air)SA

(return air)RA

OA(outside air intake)

(exhaust air outlet)EA

399798Core, air filter, High-

Efficiency filter, fan,Maintenance space

(4-15x30 oval)

79

70

0

44

27

02

70

27

1010

1144

A

15

0~

25

0

Mor

e th

an 6

00

11

0

Inspection opening

258

242

258

242

B C

LG

H R

X5-E

Co

mm

erci

al S

erie

sLo

ssnay

Ran

ge

Dimensions

Page 263

� Control up to 15 Lossnay units

� New dot matrix display

� Weekly timer (ability to pre-set air volume requirements at different intervals)

� Night purge function

� Dimensions (WxDxH) mm: 130x19x120

Notes: Please use the Lossnay Technical Databook for specific, individual model schematics.

NOMINALDIAMETER

LGH-RX5-E

LOSSNAYMODEL REFERENCE

ELECTRICAL POWER SUPPLY

STARTING CURRENT (A)

RUNNING CURRENT (A) Extra Low

Low

High

Extra High

INPUT POWER (W) Extra Low

Low

High

Extra High

AIRFLOW (m3/h) Extra Low

Low

High / Extra High

AIRFLOW (l/s) Extra Low

Low

High / Extra High

EXTERNAL STATIC Extra Low

PRESSURE (Pa) Low

High

Extra High

NOISE (dBA) Lossnay Extra Low

Low

High

Extra High

Bypass Extra Low

Low

High

Extra High

TEMPERATURE Extra Low

EXCHANGE Low

EFFICIENCY (%) High

Extra High

ENTHALPY Heating Extra Low

EXCHANGE Low

EFFICIENCY (%) High / Extra High

Cooling Extra Low

Low

High / Extra High

WEIGHT (kg)

DIMENSIONS (mm) Width

Depth

Height

DUCT SIZE (mm)

STANDARD FILTER*1

FUSE RATING (BS88) – HRC (A)

MAINS CABLE NO. CORES

COMMERCIALLGH-25RX5-E

220-240V, 50Hz

0.9

0.18

0.27

0.48

0.55

42

62

114

129

105

155

250

29

43

69

9

25

60

85

19

21.5

26

27

19

22

26.5

27.5

83.5

81.5

79

79

77.5

74

69.5

76

72.5

68

20

735

780

273

150

EU-G3

6

3

COMMERCIALLGH-35RX5-E

220-240V, 50Hz

2.4

0.30

0.51

0.74

0.92

69

116

169

212

115

210

350

32

58

97

9

30

80

160

18

23

29.5

32

18

24

30.5

32.5

88

85

80

80

81.5

76.5

71.5

81

75.5

71

29

874

888

315

150

EU-G3

6

3

COMMERCIALLGH-50RX5-E

220-240V, 50Hz

3.0

0.40

0.85

1.00

1.25

95

190

228

286

180

390

500

50

108

139

10

60

90

155

19

28

32

34

19

29

32.5

35

86

81

78

78

78

71

69

77

68

66.5

32

1016

888

315

200

EU-G3

6

3

COMMERCIALLGH-65RX5-E

220-240V, 50Hz

4.4

0.60

1.20

1.50

1.80

140

265

322

380

265

520

650

74

144

181

8

50

80

120

22

31.5

33

34.5

22.5

30.5

33.5

35

86

80

77

77

78

70.5

68.5

77

68.5

66

40

954

908

386

200

EU-G3

6

3

COMMERCIALLGH-80RX5-E

220-240V, 50Hz

3.8

0.65

1.45

1.60

1.75

145

340

370

415

355

700

800

99

194

222

20

95

120

150

22

31

33

34.5

22

32

34

35.5

87.5

80.5

79

79

79.5

72.5

71

79.5

71.5

70

53

1004

1144

399

250

EU-G3

6

3

COMMERCIALLGH-100RX5-E

220-240V, 50Hz

4.6

0.90

1.70

2.10

2.40

200

380

475

535

415

755

1000

115

210

278

18

60

110

170

22

32.5

35

37

22

33

36

38

87

83

80

80

80

74

72.5

79

73

71

59

1231

1144

399

250

EU-G3

6

3

COMMERCIALLGH-150RX5-E

220-240V, 50Hz

7.3

-

2.90

3.20

3.50

-

680

740

830

-

1300

1500

-

361

417

-

100

135

175

-

35

37.5

39

-

37

39

40.5

-

81

80

80

-

72.5

72

-

71.5

70.5

105

1004

1144

798

(SA,RA)250 (OA,EA)270x700

EU-G3

10

3

COMMERCIALLGH-15RX5-E

220-240V, 50Hz

0.8

0.15

0.25

0.38

0.46

35

59

90

110

70

110

150

19

31

42

14

40

70

105

18

23.5

27

28

19

24

28

29

85.5

84

82

82

81

77.5

75

81

76.5

73

20

735

780

273

100

EU-G3

6

3

Notes: Running Current, Input Power and Recovery Efficiency are based on the above airflow rate, power supply 240v, 50Hz. Extra High and High mode available via dip switch setting. Extra Low mode not available on sizes 150 and 200. Noise measured at 1.5m under the centre of panel.*1: EU-F7 filter available as optional parts.

Commercial Series

This commercially orientated system can be utilised virtually anywhere.

� Effective fresh air ventilation

� High heat recovery

� Free cooling function

� Good sound attenuation

� New “Hyper Eco Core”. At only 25µm the Lossnay core uses the thinnest paper in the world to achieve high enthalpy exchange efficiency

� The Lossnay-5-FSC Interface can also be used with LGH-RX5-E units.However, automatic fan speed control is with 3 speeds

Page 262

Technical Information

COMMERCIALLGH-200RX5-E

220-240V, 50Hz

11.9

-

3.40

4.20

4.80

-

785

980

1100

-

1580

2000

-

439

556

-

65

105

165

-

34

38

40

-

35

39

41

-

83

80

80

-

73.5

72.5

-

72

71

118

1231

1144

798

(SA,RA)250 (OA,EA)270x700

EU-G3

16

3

MODEL REFERENCE

LGH-15RX5-E

LGH-25RX5-E

LGH-35RX5-E

LGH-50RX5-E

LGH-65RX5-E

LGH-80RX5-E

LGH-100RX5-E

Page 137: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Lo

ssnay

Ran

geA

cces

sori

es /

Optional

Extr

as

Accessories / Optional ExtrasM Series

High Efficiency Filter PZ-25RFM - for LGH-15RX5-E / LGH-25RX5-E

PZ-35RFM - for LGH-35RX5-E

PZ-50RFM - for LGH-50RX5-E

PZ-65RFM - for LGH-65RX5-E

PZ-80RFM - for LGH-80RX5-E / LGH-150RX5-E (2 sets)

PZ-100RFM - for LGH-100RX5-E / LGH-200RX5-E (2 sets)

Page 264

The High Efficiency Filter

(with 65% colorimetricity EU-F7) can be incorporated inside the Lossnay LGH-RX5-E unit easily

Page 138: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Controls A Comprehensive Rangeof Control Options

Air Conditioning Commercial Heating

Domestic Heating Photovoltaics

Page 139: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

The Importanceof Control

Page 266

The need for control is paramount in order to optimise the performanceof any air conditioning system and minimise its running costs and theemissions generated. Mitsubishi Electric offer a wide range of controloptions designed to do just this.

Operating an air conditioning system without the right controlcan prove costly. It’s therefore important to ensure that everysystem is correctly specified to the degree of control itrequires. Mitsubishi Electric have a wide range of controlsavailable ‘off-the-shelf’ and where needed, individual controlsystems can be specifically designed to suit.

Good controls will benefit any application, large or small. Air conditioning products need to react to a variety of factors:different room sizes, usage and staff levels, changes in the climate, electronic equipment and lighting etc.

The ability to monitor the energy consumption and operationof systems is also vital. It is often said that you cannot managewhat you are not measuring. Our control systems will enablesimple measuring and monitoring of energy consumption andrunning costs to ensure operation is maintained.

So whatever the application, optimum control of air conditioningsystems is essential and will result in a constant, comfortableenvironment, which in turn is both energy and cost efficient.

A Degree of Difference

When an air conditioning system is not properly controlled, itwill not run as efficiently as it should. For every degree that thesystem deviates from the required temperature, energy costscan rise by up to 5%. Specify one of the many control optionsfrom Mitsubishi Electric to ensure air conditioning works asintended, whilst giving the optimum amount of control.

The Simpler the Better

With the array of comprehensive control systems availablefrom Mitsubishi Electric, it becomes simple to design and installair conditioning systems. From a simple hand held controller toan AG150 system - you are in control.

ControlledPerformance

Page 267

In accordance with the requirements ofPart L2 in the Building Regulations, our controlsystems provide the optimum control available,

combined with the most efficientuse of energy.

Page 140: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Application Low Cost and Features High

Option 1 Option 2 Option 3 Option 4 Option 5

Notes

On/Off remote controllerbutton lock except TCB1

AG150 andPAC-YG10HA

AT50IO InterfaceTCB1PAC-SA89TARemote On/Offor fire alarm

Relays or power supplymay be required

AG150 andPAC-YG10HA

AT50IO InterfacePAC-SA88HAMonitor run and faults

Controller will be centrallycontrolled when windowopened

---TCB1PAC-SA89TAWindowinterlocking

Available in Heat, Cooland Auto modes

AG150 andTG2000

AG150AT50PAR-F27MEAPAR-30MAASetpoint limit

Setpoint, On/Off canbe resetM2MAG150 and

TG2000AG150AT50PAR-30MAAWeekly timer

TCB1 requires thermostat,timeswitch, 12v power supplyM2MAG150 and

TG2000AG150AT50TCB1Night set back

Different options for eachchoice. Meters requiredMaxi M2MMini M2M

TG2000, AG150 andPAC-YG60MCA

AG150 andPAC-YG60MCA

AG150 and PAC-CN32WHMC-UK

Energymonitoring

Energy meters required--Maxi M2MMini M2MAG150 andPAC-YG60MCA

Load shedding

CSV data availableon a spreadsheet--Maxi M2MMini M2MAG150 and

TG2000Trend logging

PAC-SA89TA requires athird party timer---AG150PAC-SA89TANight mode

PT100 sensor required--Maxi M2MMini M2MAG150 andPAC-YG63MCA

Ambient tracking

Volt free contact forkey card normally open---

MELCOTELTM

and PAC-SA89TA

AG150, AG150-Interlockand PAC-SA89TA

Key card interlockfor hotel

Volt free contact for keycard normally closed----MELCOTELTM

and PAC-SA89TAWindow sensorinterlock for hotel

For instance, 19ºC Heatand 23ºC Cool. Fan only in between

--Maxi M2MMini M2MIO Interface2 setpoints (1 forcool and 1 for heat)

Backup, rotate, join in andhigh temperature function---PANEL_RS_SMSPAR-30MAA Duty / Standby

SIM card not supplied----Micro M2MA/C faults via SMS

-----AG150Optimised start

----Maxi M2MMini M2MMini BEMS

Which Controls Product for Which Function?

NOTE: The PAC-SA89TA is also known as a 3 wire adaptor and the PAC-SA88HA is also known as a 5 wire adaptorDISCLAIMER: These options are for guidance only

Application Small Medium Large Notes

A hotel usually requires interfacing with a keycard system and window contact. The MelcotelTM

has been designed to do just this for up to 250City Multi indoor units. The MelcotelTM can alsowork without a key card system

In an office application there is usually someonemanaging the air conditioning, so the interfaceneeds to be simple to use. The user friendlyAG150 touch screen is one option, as well as the TG2000 PC graphical user interface

Retail shops are usually managed by head officesor facility management companies, so it is key tohave remote monitoring of the air conditioning,but also any building services which can also beconnected to the M2M interfaces

In small applications the M2M platform can be a solution, as well as the AG150 touch screen or the TG2000 software package for larger applications

In small applications the M2M platform can be a solution, as well as the AG150 touch screen or the TG2000 software package for larger applications

Hotel

Office

Retail

Leisure

Education

AG150

PAR-30MAA PAR-F27MEA

IO Interface

PAR-30MAAPAR-F27MEAMini M2M

PAR-30MAA PAR-F27MEAMini M2M

MELCOTELTM

AG150

Mini M2M

AG150Maxi M2M

AG150Maxi M2M

MELCOTELTM

TG2000

Maxi M2M

AG150TG2000

AG150TG2000

It is really important to match the right control with the right application. From a hotel to a retailapplication, the solution will be different and the right control must be applied.

Which Controls Product for Which Application?

Page 268 Page 269

-

Page 141: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Page 270

The need for control is paramount in order to optimise the performance of any airconditioning system and minimise its running costs. Mitsubishi Electric offer a wide rangeof control options designed to do just this.

With the array of comprehensive controlsystems available from Mitsubishi Electric, it becomes simple to design and install airconditioning systems. From a simple handheld controller to an AG150 system -you are in control.

A Wide Range ofControl Options

Remote Controllers

AT50 Controller, Centralised Controller

Interfaces

IO Interface

AG150 Controller, Centralised Controller

AT50/AG150 Controller, Touch Screen Examples

AG150 Expansion Controller (PAC-YG50ECA)

GB50ADA Controller, Centralised Controller

AG150/GB50 Controller, Web Screenshots

PAR-21PC Desktop Remote Controller

AG150/GB50 Third Party Equipment Interfaces

AG150/GB50 MelcotelTM Hotel Interface, with key card system

AG150/GB50 MelcotelTM Hotel Interface, without key card system

AG150/GB50 MelcotelTM Hotel Interface, with M2M

TG2000 Software, PC Based Software Package

TG2000 Software with Energy Monitoring

Energy Monitoring

TG2000 Software with Third Party Equipment

TG2000 WAN Software (Wide Area Network)

TG2000, Screenshots

BEMS BACnet® Interface (BAC-IP/50)

BEMS BACnet® Interface (BAC-HD150)

BEMS BACnet® Mr Slim Interface (BAC-A/50)

BEMS LonWorks® Interface (LMAP)

BEMS Modbus Interface (MOD-IP/50)

BEMS Modbus Mr Slim Interface (A32M)

BEMS Modbus Splits Interface (A1M)

BEMS KNX-EIB Interfaces (KNX-EIB-IP-15/100)

BEMS KNX-EIB Splits Interface (KNX-EIB-A-1)

BEMS Trend Interface (Trend IQ3 Excite)

M2M - Machine 2 Machine Interface (Maxi M2M-IP/50)

M2M - Machine 2 Machine Splits Interface (Mini M2M-A/16)

M2M - Machine 2 Machine Splits Interface (Micro M2M-SMS-A/08)

M2M - Machine 2 Machine Web Screenshots

Run Standby Panel (PANEL_RS_SMS)

Split-System A2M Interfaces

272

273

274

275

276

277

278

279

280

281

282

283

284

285

286

287

288

289

290

291

292

293

294

295

296

297

298

299

300

301

302

303

304

305

306

307

Page 271

Contents

Page 142: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

AT50 ControllerThe new AT50 centralised controller is a low cost version of the very popular AG150 touch screen controller. The AT50 offers the main AG150 functionality, with a very simple and easy to use 5 inch touch screen.

AT50 PAC-SC51KUA

Co

ntro

lsR

ange

Rem

ote

Contr

olle

rs /

AT

50 C

ontr

olle

r

Technical Information

Page 273

AT50 Controller

MAX No. OF INDOOR UNITS

ON/OFF

MODE SELECTION

TEMPERATURE SETTING

TIMER OPERATION

AIR FLOW DIRECTION

FAN SPEED SETTING

PERMIT/PROHIBIT FUNCTION

INDOOR RETURN AIR TEMPERATURE

ERROR INDICATION

TEST RUN FUNCTION

VENTILATION INTERLOCK

FIRE ALARM

NIGHT SET BACK

POWER SUPPLY

COMPATIBILITY

DIMENSIONS - mm (WxDxH)

TOUCH SCREEN

FUNCTION

5” QVGA touch screen

Up to 50 indoor units can be connected

Run and Stop operation for a single group

Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit.Auto mode is available with only R2 and WR2 systems

Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C

Annual or weekly. Night set back option available allowing the setpoint to be set to 12ºC

Air Flow angles:100º-80º-60º-40º and auto swing

4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi

Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated

Displays the measured intake temperature from each group

Displays a 4 digit code and the affected unit address. An error log is held

Allows each unit within the group to operate in test mode

Allows the group to be interlocked with a heat recovery Lossnay unit

Units will be switched off and the remote controller will be locked under fire alarm condition

Power supply 240VAC 0.5A (PAC-SC51KUA required)

City Multi or Mr Slim via PAC-SF81MA or M Series via MAC-399IF

180x30x120

DESCRIPTION

Remote Controllers

Remote Controllers

PAR-FL32MAPAR-30MAA PAR-F27MEAPAC-YT51CRB PAC-SE51CRA BS-51COV-B PS-51COV-B PB-51COV-B

ON/OFF

MODE SELECTION

TEMPERATURE

SETTING

FAN SPEED SETTING

SETPOINT LIMIT

AIRFLOW DIRECTION

INDEPENDENT VANE

CONTROL

TIMER OPERATION

PERMIT / PROHIBIT

FUNCTION

INDOOR RETURN AIR TEMPERATURE

ERROR INDICATION

TEST RUN FUNCTION

VENTILATION INTERLOCK

OPTIONAL COVER

CONTACT NUMBERUNDER FAULT CONDITIONS

EASY MAINTENANCEWITH MR SLIM

BACKLIGHT DISPLAY

BUTTON LOCK

ENERGY SAVING

SILENT MODE

NIGHT SET BACK

RUN / STANDBY WITH

MR SLIM

COMPATIBILITY

DIMENSIONS - mm (WxDxH)

FUNCTION

Run and Stop operation for a single group

Switches between Cool/Dry/Auto/Fan/Heat.Operation mode will vary depending on theindoor unit. Auto mode is available with only R2 and WR2 systems

Sets the groups temperature control. Cool/Dry: 19-30°C Heat: 17-28°C Auto: 19-28°C

4 speed - Lo-Mi1-Mi2-Hi 2 speed - Lo-Hi

Limit the setpoint range

Air Flow angles:100º-80º-60º-40ºand auto swing

Only available with PLA-RP-BA, PLFY-P-VBM-E and PLFY-P-VCM-E

ON/OFF time can be set.

Run/Stop, Temperature Setting, Mode Selectionand Filter Reset functions can be prohibited via a higher level system controller

Measures the intake temperature of the master unit within the group

Displays a 4 digit code and the affected unit address

Allows each unit within the group to operate in test mode

Allows the group to be interlocked with a heat recovery Lossnay unit

Brushed Stainless Steel

Polished Stainless Steel

Polished Brass

Displays under fault condition, the fault code of the unit with its address and the contact number to call

Able to monitor info about the compressor(running current, running time, On/Off time).Also able to monitor sensors: h-exh, OU outlet,OU temp, IU inlet, IU h-exh and filter usage

Backlight display. Displays current time

Able to lock all controller buttons, or all controller buttons except On/Off

Reset the unit setpoint after a period of time

Activate with scheduling the silent modeon the outdoor unit

Maintain a min and max temperature

Able to switch over two systems every week. If one fails, the other system starts. If thetemperature is too high, the two systems start.

Compatible with:

DESCRIPTION PAC-YT51CRB PAC-SE51CRA PAR-30MAA PAR-F27MEA PAR-FL32MA

Weekly Weekly Daily Daily Daily Daily

Our air conditioning systems are supported by a multitude of remote controllers. Each remote controller type, whilstbeing able to support the general control and monitoring functions for a group of indoor units, can also offer other unique operational features.

Mr Slim or M Series (via MAC-397IF)

City Multi, Mr Slim(via PAC-SF81MA)

or M Series(via MAC-399IF)

City Multi, Mr Slim(via PAC-SF81MA)

or M Series(via MAC-399IF)

City Multi, Mr Slim or M Series (via MAC-397IF)

City Multi (via PAR-FA32MA) or Mr Slim (via PAR-FA32MA)

120x41x70 120x41x70 120x19x120 130x19x120 157x18x57

Operation Display Operation Display Operation Display Operation Display Operation Display

� � � � � � � � � �

� � � � � � � � � �

� �

� �

� � � �

� � � �

� �

� �

� �

� �

� �

� �

� � � � � � � �

� � � � �

� �

� � � �

� �

� �

� �

� � � � � � � �

Technical Information

Page 272

� �

During unoccupied hours the system works in a reduced state. For instance, an unoccupied room in heating mode will keepthe temperature of the room between 16 and 19°C. In cooling the temperature will range between 24 and 26°C

Page 143: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

IO InterfaceThe new IO interface has been developed to allow third party systems, for instance BEMS companies, to easily controland monitor our air conditioning systems using simple volt free contacts and 0 to 10VDC signals. By working veryclosely with our main retail clients we have added some beneficial energy saving features, whilst still offering anacceptable level of control for retail applications. To avoid wasting energy the IO interface can also be used tointerlock third party heating systems to our air conditioning.

IO Interface

IO Interface

UNIT 1 or 16*1

ON/OFF Run and Stop operation for a single group Volt Free ContactInput

ENERGY SAVE Energy Save can be activated. 2 options are available Volt Free ContactInput

TEMPERATURE SETTING Sets the groups temperature control 0 to 10VDCInput

MODE Switches between Cool/Dry/Auto/Fan/Heat. Operation modewill vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems

0 to 10VDCInput

LOCK Run/Stop, Temperature Setting, Mode Selection and FilterReset functions can be prohibited

Volt Free ContactInput

FAN SPEED 4 speed - Lo-Mi1-Mi2-Hi2 speed - Lo-Hi

0 to 10VDCInput

RUN STATUS - Volt Free ContactOutput

FAULT - Volt Free ContactOutput

HEAT / COOL Activates when unit is in heating or cooling mode Volt Free ContactOutput

THERMO Activates when room temperature is 2ºC away from setpoint Volt Free ContactOutput

COMPATIBILITY Mr Slim and M Series --

DIMENSIONS - mm (WxDxH) 85x32x138 --

FUNCTION DESCRIPTION IO INTERFACE

Co

ntro

lsR

ange

Technical Information

INPUTS / OUTPUTS

Inte

rfac

es /

IO

Inte

rfac

e

Page 275

Energy Saving Features

MODE 1 MODE 2

*1 The IO Interface can control up to 16 indoor units when the fault output is not used. When the fault output is used only one indoor unit can be controlled. Page 274

InterfacesA range of newly created interfaces are now available for use when connecting to third party controllers.

TCB1

TCB1

Interfaces

ON/OFFBUT CENTRALLYCONTROLLED

ON/OFF BUTNOT CENTRALLY CONTROLLED

TEMPERATURE SETTINGS

RUN INDICATION

ERROR INDICATION

COMPATIBILITY

DIMENSIONS - mm(WxDxH)

FUNCTION

ON/OFF control. Remote controller ON/OFF button deactivated

ON/OFF control. Remote controller ON/OFF button activated

Sets the groups temperature control. Cool/Dry: 19-30°C Heat: 17-28°C Auto: 19-28°C

Interface compatible with:

DESCRIPTION TCB1

Technical Information

Control Monitor

PAC-SA88HA

Control Monitor

PAC-SA89TA

Control Monitor

80x45x80

Mr Slim

City Multi

Mr Slim

City Multi

Mr Slim

City Multi

PAC-SA88HAPAC-SA89TA

(12VDC)

(VFC)

(12VDC)

(12VDC)

NOTE: VFC: Volt free contact.PAC-SA89TA is also known as a 3 wire adaptor.PAC-SA88HA is also known as a 5 wire adaptor.

PAC-SA88HAPAC-SA89TA

The energy saving mode 1 sets the indoor unit to Auto modewhenever a momentary signal is applied to the ‘Energy Save’ input or whenever the on/off state is changed from OFF to ON.The unit will operate in AUTO for 0.5, 1 or 2hours and then revert back to fan only.

The timer can be reset using the Energy Save input.

The energy saving mode 2 sets two setpoints for the indoorunit, one for heating and one for cooling. In between theindoor unit will be running in fan only mode.

OFF OFFAUTO FAN

OFF OFFAUTO AUTOFAN FAN

09.00 11.00 13.00 15.00 17.00 19.00

09.00 11.00 13.00 15.00 17.00 19.00Active via push button

2524232221201918

COOLING MODE

FAN ONLY MODE

HEATING MODE

Max No. of indoor units -

Page 144: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

AT50/AG150 Controller Touch Screen Examples

Page 277

Co

ntro

lsR

ange

AT50 Home Screen 1 AG150 Home Screen 1

AT50 Home Screen 2 AG150 Home Screen 2

AG150 Home Screen 3AT50 Home Screen 3

AT50 Indoor Unit Settings AG150 Indoor Unit Settings

AT50 Scheduling AG150 Scheduling

DEMONSTRATION

Touch Screen Centralised Controller with WebServer Capabilities

AG150 Controller

The AG150 Mitsubishi Electric centralised controller offers a large 9 inch touch screen display with easy control of up to 50indoor units. The AG150 can calculate the energy used for each system. The refrigerant status check function can beactivated regularly (in conjuction with the new YJM-A City Multi range) and an Internet connection with SSL security is also available to monitor and control the AG150 remotely and receive Email under fault conditions.

AG150 - Basic

AG150 - Energy

Web monitoring, Email, Annual scheduling AG150 - VRC Virtual remote controllers

Energy monitoring, energy saving, load shedding AG150 - Interlock Interlocking function

AG150 Software Options - Pin Code Activation

Technical Information

ETHERNET

AG150

M-NET

PAC-SC51KUA

Visit wwwL1.mitsubishielectric.co.jp/wink_doc/wink_files/acr/menu/ag150

Page 276

AG150 Controller

OPERATION PLATFORM

MAX No. OF INDOOR UNITS

ON/OFF

MODE SELECTION

TEMPERATURE SETTING

TIMER OPERATION

AIR FLOW DIRECTION

FAN SPEED SETTING

PERMIT/PROHIBIT FUNCTION

INDOOR RETURN AIR TEMPERATURE

ERROR INDICATION

TEST RUN FUNCTION

VENTILATION INTERLOCK

OPTIMISED START

AUTOMATIC SETPOINT ADJUSTMENT

AUTO LOCK

NIGHT SET BACK

AutoCAD DRAWING

WEB LOGIN

WEB SETPOINT LIMIT

WEB AUTO CHANGEOVER

WEB INITIAL SETTING

WEB REFRIGERANT STATUS CHECK

WEB-INTERLOCK

WEB-LOAD SHEDDING

EXTERNAL INPUT/OUTPUT

FIRE ALARM

POWER SUPPLY

COMPATIBILITY

DIMENSIONS - mm (WxDxH)

TOUCH SCREEN

FUNCTION

Wide high resolution 9” touch screen

CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7

Up to 50 indoor units can be connected or 150 using an expansion controller (PAC-YG50ECA)

Run and Stop operation for a single group

Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit.Auto mode is available with only R2 and WR2 systems

Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C

Annual or weekly. Night set back available allowing the setpoint to be set to 12ºC

Air Flow angles:100º-80º-60º-40º and auto swing

4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi

Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated

Displays the measured intake temperature from each group

Displays a 4 digit code and the affected unit address including the description of the error. An error log is held

Allows each unit within the group to operate in test mode

Allows the group to be interlocked with a heat recovery Lossnay unit

The equipment is started only as early as required to bring the building to a setpoint at the time it will be occupied.Running in an optimal state helps reduce energy usage.

The AG150 will change the setpoint depending of the outdoor temperature. PAC-YG63MCA and a PT100 sensor arerequired (PT100 sensor not supplied by MEUK). This function is only available in COOL mode

The AG150 screen can be password protected. When the screen goes to standby and when the AG150 restarts,a username and password will be required

During unoccupied hours the system works in a reduced state. For instance, an unoccupied room in heating mode will keepthe temperature of the room between 16 and 19°C. In cooling the temperature will range between 24 and 26°C

Administrator able to allow specific function access to guest

Reduce the setpoint band of each individual unit (e.g. 23ºC to 25ºC)

Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements

Commission the AG150 from the web pages

Activate refrigerant volume checking function on Modular City Multi systems

The AG150 can interlock indoor unit input and output together. For instance, this function could be used for Hotelapplications, if card in, set unit to ON, AUTO 21ºC and if card out, set the unit to night set back. This function could alsobe set in conjunction with PIR sensor in meeting rooms

Activate energy saving mode when energy consumption is too high

Hardwired connections are available for : Inputs: Level Signal-Batch Start/Stop, Batch Emergency StopOutputs: Start/Stop Status, Error/Normal Status

Units will be switched off and the remote controller will be locked under fire alarm condition via a PAC-YG10HA

Power supply 240VAC 0.5A (PAC-SC51KUA required)

City Multi or Mr Slim via PAC-SF81MA or M Series via MAC-399IF

300x62x175

DESCRIPTION

A floor plan of the building in auto-cad format can be uploaded. For the facilities department it makes viewing and adjusting settings easier

Viewed using Microsoft® Internet Explorer

AG1

50 C

ontr

olle

r /

AT

50/A

G1

50 C

ont

rolle

r To

uch

Scre

en E

xam

ples

Page 145: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Centralised Controller with WebServer Capabilities

GB50ADA Controller

G50 - EC

G50 - ES

G50 - PC

G50 - VRC

Energy Charge

Energy Saving Capability

Peak Cut Control

Virtual Remote Controllers

GB50 Software Options - Pin Code Activation

ETHERNET

The GB50 has been developed to access all your control functions from the comfort of your own PC, without the need for a controller keypad or LCD display and at a very competitive price.

GB50ADA Controller

OPERATION PLATFORM

MAX No. OF INDOOR UNITS

ON/OFF

MODE SELECTION

TEMPERATURE SETTING

FAN SPEED SETTING

AIR FLOW DIRECTION

TIMER OPERATION

PERMIT/PROHIBIT FUNCTION

INDOOR RETURN AIR TEMPERATURE

ERROR INDICATION

TEST RUN FUNCTION

VENTILATION INTERLOCK

WEB LOGIN

WEB SETPOINT LIMIT

WEB AUTO CHANGEOVER

WEB INITIAL SETTING

WEB REFRIGERANT STATUS CHECK

WEB-INTERLOCK

WEB-LOAD SHEDDING

EXTERNAL INPUT/OUTPUT

FIRE ALARM

POWER SUPPLY

COMPATIBILITY

DIMENSIONS - mm (WxDxH)

FUNCTION

CPU 1000 Mhz, 512MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7

Up to 50 indoor units can be connected

Run and Stop operation for a single group

Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems

Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C

4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi

Air Flow angles:100º-80º-60º-40º and auto swing

Annual or weekly. Night set back option available allowing the setpoint to be set down to 12ºC

Individual prohibit operations for each remote controller function (Run/Stop,Temperature Setting, Mode Selection and Filter Reset) can be activated

Displays the measured intake temperature from each group

Displays a 4 digit code and the affected unit address. An error log is held showing the last 64 date stamped alarms

Allows each unit within the group to operate in test mode

Allows the group to be interlocked with a heat recovery Lossnay unit

Hardwired connections are available for : Inputs: Level Signal-Batch Start/Stop, Batch Emergency StopOutputs: Start/Stop Status, Error/Normal Status

Units will be switched off and the remote controller will be locked under fire alarm condition via a PAC-YG10HA

Power supply 240VAC 3.2A

City Multi or Mr Slim via PAC-SF81MA or M Series via MAC-399IF

250x97x266

DESCRIPTION

Technical Information

M-NET

Viewed using Microsoft® Internet Explorer

GB50ADA

Co

ntro

lsR

ange

PAC

-YG

50EC

A / G

B50

AD

A C

ont

rolle

r

Page 279

Technical Information

PAC-YG50ECA

AG150 / PAC-YG50ECA CONNECTION

POWER SUPPLY

DIMENSIONS - mm (WxDxH)

FUNCTION

Ethernet. Ethernet hub and network cables required and not supplied by MEUK

240VAC 3.2A

250x97x266

DESCRIPTION

PAC-YG50ECA

0 to 50

51 to 100

101 to 150

NUMBER OF INDOOR UNITS

1

1

1

0

2

3

NUMBER OF AG150 REQUIRED NUMBER OF PAC-YG50ECA REQUIRED

AG150 Expansion Controller

PAC-YG50ECA

The PAC-YG50ECA expansion controller allows the AG150 to monitor and control up to 150 indoors units.

ETHERNET

PAC-SC51KUA

PAC-YG50ECA

PAC-YG50ECA

PAC-YG50ECA

AG150

HUB

Page 278

Administrator able to allow specific function access to guest

Reduce the setpoint band of each individual unit (e.g. 23ºC to 25ºC)

Automatically switch heat pump outdoor unit to cooling or heating mode depending on the requirements

Commission the GB50 from the web pages

Activate refrigerant volume checking function on Modular City Multi systems

The GB50 can interlock indoor unit input and output together. For instance, this function could be used for Hotelapplications, if card in, set unit to ON, AUTO 21ºC and if card out, set the unit to night set back. This function could also be set in conjunction with PIR sensor in meeting rooms

Activate energy saving mode when energy consumption is too high

Page 146: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PAR-21PC Desktop Remote Controller

More and more customers are using the AG150/GB50 controllers directly from their computers, so MitsubishiElectric has launched a new, even simpler alternative which presents the customer with what looks like a standardremote controller interface - on their PC desktop. Called the PAR-21PC, the new application can also be minimisedin the Desktop Toolbar, just like other Windows applications, so that the customer can have immediate control with just one click of the mouse.

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50

ETHERNET

PAR-21PC Desktop Remote Controller

OPERATION PLATFORM

MAX No. OF INDOOR UNITS

ON/OFF

MODE SELECTION

TEMPERATURE SETTING

FAN SPEED SETTING

AIR FLOW DIRECTION

CLOCK DISPLAY

INDOOR RETURN AIR TEMPERATURE

ERROR INDICATION

TIMER OPERATION

COMPATABILITY

FUNCTION

CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2

Up to 16 indoor units within a group

Run and Stop operation for a single group

Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems

Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C

4 speed: Lo-Mi1-Mi2-Hi, 2 speed: Lo-Hi

Air Flow angles:100º-80º-60º-40º and auto swing

Displays the time on the desktop controller

Displays the measured intake temperature from each group

Displays a 4 digit code and the affected unit address.

Weekly. Maximum of 3 time sequences with 3 Start/Stop times per day for all groups can be allocated

AG150 and GB50

DESCRIPTION

Technical Information

M-NET

PAC-SC51KUA

*NOTE 1

Page 281

Co

ntro

lsR

ange

AG

150/G

B50 C

ontr

olle

r W

eb S

cree

nsh

ots

/PA

R-2

1PC

Des

ktop R

emao

teC

ontr

olle

r

AG150/GB50 Controller Web Screenshots

Login

Access to the web pages is secured using a customisedusername and password.

Monitor Air Conditioning - Overview

The first screen allows you to monitor all the units connected to theAG150/GB50. Each icon displays On/Off, Faults and timer On/Off.

Monitor Air Conditioning - Block view

Each area of the building can be displayed with informationabout On/Off, Setpoint , Mode and Temperature.

Remote Controller Settings

Click on any icons in the Monitor View page to access theremote controller. Lossnay units can also be controlled. Buttons on the local controllers may be locked (On/Off, Mode, Setpoint, Filter Reset).

Daily, Weekly and Annual Scheduling (AS PIN code)

Scheduling may be set from the web pages. A night set back operation is available (Heat, 12ºC).Standard on the AG150/GB50.

Monitor Fault Codes

Faults with the unit address can be displayed under fault conditions. Email status can also be shown.

Multiple Users (VRC PIN code)

If the AG150/GB50 is connected to an office LAN, the staffwill then be able to access the web pages. With VRC eachmember of staff will have their own username and password.

Multiple Users (VRC PIN code)

Installation costs will be reduced as no wall remotecontrollers will need to be purchased and installed.

Icons available to suit model type installed

Page 280

Page 147: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

MELCOTELTM

MAX No. OF INDOOR UNITS

TIME TO SWITCH ON

ON/OFF

MODE SELECTION

TEMPERATURE SETTING

OCCUPIED ROOM SETTING

UNOCCUPIED ROOM SETTING

SEASONS

OPTIONAL WINDOW CONTACT

AUTOMATIC SETPOINT

ADJUSTMENT NIGHT TIME OFFSET

INDOOR UNIT CONNECTION

SOFTWARE

FIRE ALARM

POWER SUPPLY

COMPATIBILITY

DIMENSIONS - mm (WxDxH)

FUNCTION DESCRIPTION

Key Card

WindowControl

Key Card

WindowControl

Key Card

WindowControl

ETHERNET

MelcotelTM

Technical Information

M-NET

PAC-SC51KUA

AG150/GB50 MelcotelTM

Hotel Interfacewith Key Card System

The MelcotelTM hotel interface allows a hotel (for example) to have more accurate control over its air conditioning. The MelcotelTM works in conjunction with the key card system installed in each bedroom in many hotels. When the room is occupied, the MelcotelTM will switch ON the unit and reset the air conditioning to predetermined settings (for instance AUTO, 21ºC). When the room is unoccupied, the MelcotelTM will monitor the temperaturein the room. If the temperature is too low or too high, the MelcotelTM will restart the unit. The MelcotelTM alsooffers temperature adjustment facility based on the outside temperature and window open control, that allowsthe air conditioning to be switched off and controlled centrally when a window is opened. All of these functionsprovide a higher level of control and therefore more energy saving and a reduction in running costs.

AG150

Up to 250 indoor units

<30s

Run and Stop operation for a single group

Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems

Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C

Configurable. ON, AUTO, 21ºC (Factory setting)

Up to 4 seasons can be set-up to allow different occupied and unoccupied settings (Setpoint and mode)

If a window sensor is wired to the indoor unit, the MelcotelTM will automatically switch OFF the indoor unitwhen the window is opened

The MelcotelTM will offset the occupied setpoint depending on the temperature outside (outdoor sensor supplied)

During the night the MelcotelTM can offset the setpoint or just switch OFF the unit

The key card and the window contact is connected back locally to CN32. PAC-SA89TA required for each indoor unit

The MelcotelTM Configuration Manager allows the installer to set-up the interface using a USB cable. The MelcotelTM Live Statusallows the user to monitor all the different values, for instance, Setpoint, Mode, Key Card IN or OUT, Window Contact etc

Units will be switched off and the remote controller will be locked under fire alarm condition

240 VAC 2A

GB50 and AG150, but City Multi only

300x70x350

DEMONSTRATION Visit www.melcotel.co.uk for more details

USB

If the temperature is above 26ºC the MelcotelTM

restarts the unit to ON, COOL, 21ºC and stopsthe unit when the temperature has reached 24ºC (Factory setting)

If the temperature is below 16ºC the MelcotelTM restartsthe unit to ON, HEAT, 19ºC and stops the unit when thetemperature has reached 18ºC (Factory setting)

Page 283

Co

ntro

lsR

ange

AG

150/

GB

50 T

hird

Par

ty E

quip

men

t In

terf

aces

/M

elco

telT

M

Hote

l In

terf

ace

with K

ey C

ard S

yste

m

The new third party equipment interfaces allow the user to monitor and control third party equipment from theAG150/GB50 web pages.

AG150/GB50

Third Party Equipment Interfaces

*NOTE 1

FUNCTION

MAX No. OF INPUTS

MAX No. OF OUTPUTS

MAX No. OF EQUIPMENT

POWER SUPPLY

MONITOR

CONTROL

SIGNAL

DIMENSIONS - mm (WxDxH)

DESCRIPTION PAC-YG66DCA PAC-YG63MCA

Power supply required

Third Party Interfaces

From AG150/GB50 web pages or TG2000

From AG150/GB50 web pages or TG2000

Signal required to monitor and control equipment

2 x Digital

2 x Digital

2

-

-

-

-

-

-

24VDC

Run / Faults

On/Off

Volt free contact

200x45x120

2 x Analogue

24VDC

Temperature / Humidity

-

Temperature 4-20mA / 1-5V / 0-10V / Pt100Humidity 4-20mA / 1-5V / 0-10V

200x45x120

Technical Information

PAC-YG66DCA PAC-YG63MCA

General Equipment

Third party equipment can be monitored and controlledfrom the web pages.

Temperature / Humidity

Temperature and humidity can be monitored.

Trend Logging

Temperature and humidity can be recorded and displayed.

Temperature / Humidity Limit

Limit (high and low) can be set to trigger alarms via email.

ETHERNET

EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50NOTE 2: Temperature Sensors and Humidity Sensors not supplied by MEUK

Page 282

Page 148: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

MELCOTELTM

MAX No. OF INDOOR UNITS: UP TO 250

ON/OFF

MODE

ROOM TEMPERATURE

SET TEMPERATURE

SET BACK

KEY CARD

WINDOW SENSOR

EXTERNAL TEMPERATURE

FUNCTION

MelcotelTM

Technical Information

AG150/GB50 MelcotelTM

Hotel Interfacewith Machine 2 Machine

The MelcotelTM hotel interface can be connected to the Mini M2M Machine 2 Machine interface to allowremote monitoring of the air conditioning, but also the window contact and the key card system.

MEUK

M2M SERVER

GPRS

Mini M2M-A/16

MelcotelTM

Mini M2M-A/16

DEMONSTRATION Visit www.melcotel.co.uk for more details

Page 285

Co

ntro

lsR

ange

Mel

cote

lTM

Hote

l Int

erfa

ce w

itho

ut K

ey C

ard

Syst

em /

Mel

cote

lTM

Hote

l In

terf

ace

with M

2M

MELCOTELTM

MAX No. OF INDOOR UNITS

TIME TO SWITCH ON

ON/OFF

MODE SELECTION

TEMPERATURE SETTING

OCCUPIED ROOM SETTING

UNOCCUPIED ROOM SETTING

SEASONS

OPTIONAL WINDOW CONTACT

AUTOMATIC SETPOINT

AUTO SWITCH OFF

ADJUSTMENT NIGHT TIME OFFSET

INDOOR UNIT CONNECTION

SOFTWARE

FIRE ALARM

POWER SUPPLY

COMPATIBILITY

DIMENSIONS - mm (WxDxH)

FUNCTION

Up to 250 indoor units

<30s

Run and Stop operation for a single group

Switches between Cool/Dry/Auto/Fan/Heat. Operation Mode will vary depending on the indoor unit. Auto mode is available with only R2 and WR2 systems

Sets the groups temperature control. Cool/Dry: 19-30°C, Heat:17-28°C, Auto: 19-28°C

Configurable. ON, AUTO, 21ºC (Factory setting)

Up to 4 seasons can be set-up to allow different occupied and unoccupied settings (Setpoint and mode)

If a window sensor is wired to the indoor unit, the MelcotelTM will automatically switch OFF the indoor unitwhen the window is opened

The MelcotelTM will offset the occupied setpoint depending on the temperature outside (outdoor sensor supplied)

6 Off times can be preset to regularly switch OFF the indoor unit

During the night the MelcotelTM can offset the setpoint or just switch OFF the unit

The window contact is connected back locally to CN32. PAC-SA89TA required for each indoor unit

The MelcotelTM Configuration Manager allows the installer to set-up the interface using a USB cable. The MelcotelTM

Live Status allows the user to monitor all the different values, for instance, Setpoint, Mode, Window Contact etc

Units will be switched off and the remote controller will be locked under fire alarm condition

240 VAC 2A

GB50 and AG150, but City Multi only

300x70x350

DESCRIPTION

If the temperature is below 16ºC the MelcotelTM restarts the unit to ON, HEAT, 19ºC and stops the unit when the temperature has reached 18ºC (Factory setting)

If the temperature is above 26ºC the MelcotelTM restartsthe unit to ON, COOL, 21ºC and stops the unit whenthe temperature has reached 24ºC (Factory setting)

WindowControl

WindowControl

Technical Information

AG150/GB50 MelcotelTM

Hotel Interfacewithout Key Card System

The MelcotelTM controller allows a hotel (for example) to have more accurate control over its air conditioning. When theunit has been switched ON by a user, the room is deemed as occupied and the MelcotelTM resets the air conditioning topredetermined settings (for instance AUTO, 21ºC). After a preset time, the MelcotelTM will switch OFF the unit automatically.When the room is unoccupied, the MelcotelTM will monitor the temperature in the room. If the temperature is too low ortoo high, the MelcotelTM will restart the unit. The MelcotelTM also offers temperature adjustment facility based on the outsidetemperature and window open control, that allows the air conditioning to be switched off and controlled centrally when awindow is opened. All of these functions provide a higher level of control and therefore more energy saving and a reduction in running costs.

DEMONSTRATION Visit www.melcotel.co.uk for more details

ETHERNET

MelcotelTM

M-NET

PAC-SC51KUA

AG150

USB

WindowControl

Page 284

Page 149: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

TG2000 Software with Energy Monitoring

M-NET

ETHERNET

PC Based Software PackageThe TG2000 centralised PC based graphical software package allows the operator to control and monitor upto a maximum of 2000 indoor units. This software has been designed to connect directly to an air conditioningsystem via the AG150/GB50 controller, allowing the operator all the required functionality to control andmonitor the complete air conditioning system from a central location. In addition to providing a centralisedcontrol facility, the TG2000 allows complete energy consumption data to be logged with user definable billing groups and electrical tariffs for billing purposes.

Technical Information

PAC-SC51KUA

*NOTE 1

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50NOTE 2: Energy Meters not supplied by MEUK

TG2000 Software with Energy Monitoring

OPERATING PLATFORM

MAX No. OF INDOOR UNITS

OPERATIONAL SECTIONS

ON/OFF

OPERATION MODE

SET TEMPERATURE

AIR SPEED

REMOTE CONTROLLER

PROHIBIT/PERMIT

ABNORMALITY (FAULT) MONITORING

ROOM TEMPERATURE MONITORING

SCHEDULED ON/OFF

ENERGY CHARGING

WEB REFRIGERANT STATUS CHECK

ENERGY CHARGING

ENERGY SAVE CONTROL

LOAD SHEDDING

TREND LOGGING

GRAPHICAL SCREENS

EMAIL

FUNCTION

CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7

2000 Indoor units, 50 indoor units per AG150/GB50

The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation,monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration

Indicates the On/Off status of each group within the selected graphical screen or entire building

Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen

Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode

Displays the current fan speed setting for each group on the selected graphical screen

Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen

Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code

Displays the return air temperature of the master indoor unit within a group

On/Off schedules can be set for each group, each graphical screen or the entire building

Able to create or email bills for individual indoor units, groups of indoor units or a complete system (Optional) via the PAC-YG60MCA

Activate refrigerant volume checking function on Modular City Multi systems

Able to create bills for individual indoor units, groups of indoor units or a complete system (Optional)via the PAC-YG60MCA

Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional)

Activate energy saving mode when energy consumption is too high

Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit, watt-hour meter and then email to customer

The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located

The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history

DESCRIPTION

METER 1 METER 2 METER 3 METER 4

PAC-YG60MCA

Page 287

Co

ntro

lsR

ange

TG

2000 S

oft

war

e /

TG

2000 S

oft

war

e w

ith E

ner

gy M

onitori

ng

TG2000 Software

M-NET

ETHERNET

PC Based Software PackageThe TG2000 centralised PC based graphical software package allows the operator to control and monitor up to amaximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning system via theAG150/GB50 controller, allowing the operator the required functionality to control and monitor the complete air conditioning system from a central location.

Technical Information

PAC-SC51KUA

*NOTE 1

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50

TG2000 PC Based software that works in conjunction with AG150/GB50 Controller

OPERATING PLATFORM

MAX No. OF INDOOR UNITS

OPERATIONAL SECTIONS

ON/OFF

OPERATION MODE

SET TEMPERATURE

AIR SPEED

REMOTE CONTROLLER

PROHIBIT/PERMIT

ABNORMALITY (FAULT) MONITORING

ROOM TEMPERATURE MONITORING

SCHEDULED ON/OFF

ENERGY SAVE CONTROL

TREND LOGGING

GRAPHICAL SCREENS

EMAIL

FUNCTION

CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4or Windows Professional XP service pack 2 or Windows Vista or Windows 7

2000 Indoor units, 50 indoor units per AG150/GB50

The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration

Indicates the On/Off status of each group within the selected graphical screen or entire building

Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen

Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode

Displays the current fan speed setting for each group on the selected graphical screen

Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen

Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code

Displays the return air temperature of the master indoor unit within a group

On/Off schedules can be set for each group, each graphical screen or the entire building

Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional)

Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by group or by indoor unit, watt-hour meter and then email to customer

The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located

The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history

DESCRIPTION

Page 286

Page 150: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Energy monitoring is key to comply with Part L2 regulations. Some time ago we introduced the PAC-YG60MCA MNETinterfaces, which can be connected anywhere on our MNET network and will monitor up to 4 pulse meters. These interfacesmake installation easier, more cost effective and are shown in option A below.

This year, all of our City Multi outdoor units now have a direct connection to pulse meters. This means that the pulse meter canbe connected to the outdoor unit directly, negating the need for interfaces, panels and a power supply and therefore reducing theinstallation cost significantly. This is shown in option B below.

Energy Monitoring

FUNCTION

OUTDOOR kW

INDOOR kW

PRODUCT REQUIRED DESCRIPTION

Pulse Meter Direct Connection to City Multi Outdoor Unit

Product Required

The energy consumption of the outdoor can be monitored using the AG150 Webpages

The energy consumption of the indoor unit can be estimated using theTG2000 software package. The software package will also allow the enduser to generate bills with multiple tariffs

AG150, AG150-BasicEnergy Meters

AG150, AG150-BasicAG150-Energy, TG2000Energy Meters

Technical Information

Page 288

Cable required to connect the pulse meter to the outdoor unit

Jumper to activate the outdoor pulse input

PAC-SA89TA

PAC-CN32WHMC-UK

M-NET

ETHERNET

PAC-SC51KUA

*NOTE 1

METER 1 METER 2 METER 3 METER 4

PAC-YG60MCA

M-NET

ETHERNET

PAC-SC51KUA

*NOTE 1

METER 1

PAC-YG60MCA

Option A:

Option B:

Page 289

Co

ntro

lsR

ange

Ener

gy M

oni

tori

ng /

TG

2000

Soft

war

e w

ith

Thi

rd P

arty

Equ

ipm

ent

M-NET

ETHERNET

PC Based Software PackageThe TG2000 centralised PC based graphical software package allows the operator to control and monitor up to amaximum of 2000 indoor units. This software has been designed to connect directly to an air conditioning system via the AG150/GB50 controller, allowing the operator all the required functionality to control and monitor thecomplete air conditioning system from a central location. In addition to providing a centralised control facility, the TG2000 allows you to monitor and control third party equipment.

Technical Information

PAC-SC51KUA

*NOTE 1

PAC-YG66DCA PAC-YG63MCA

EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

TG2000 Software with Third Party Equipment

OPERATING PLATFORM

MAX No. OF INDOOR UNITS

OPERATIONAL SECTIONS

ON/OFF

OPERATION MODE

SET TEMPERATURE

AIR SPEED

REMOTE CONTROLLER

PROHIBIT/PERMIT

ABNORMALITY (FAULT) MONITORING

ROOM TEMPERATURE MONITORING

SCHEDULED ON/OFF

ENERGY SAVE CONTROL

TREND LOGGING

GRAPHICAL SCREENS

THIRD PARTY EQUIPMENT MONITOR

THIRD PARTY EQUIPMENT CONTROL

EMAIL

FUNCTION

CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000 service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7

2000 Indoor units, 50 indoor units per AG150/GB50

The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation, monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration

Indicates the On/Off status of each group within the selected graphical screen or entire building

Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen

Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode

Displays the current fan speed setting for each group on the selected graphical screen

Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen

Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code

Displays the return air temperature of the master indoor unit within a group

On/Off schedules can be set for each group, each graphical screen or the entire building

Individual indoor unit, group of indoor units or a complete system can be controlled. There are various energy saving options available (Optional)

Able to log: Return air temperature, setpoint, mode, On/Off, power consumption by groupor by indoor unit, watt-hour meter and then email to customer

The complete system configurations can be allocated between multiple screens. Each screen can displaya bitmap image representing the area of the building or floor where the units or groups are physically located

Monitor general equipment Run and Faults via the PAC-YG66DCA interface and Temperature and Humidity via the PAC-YG63MCA

Control general equipment On/Off via the PAC-YG66DCA

The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history

DESCRIPTION

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50NOTE 2: Temperature and Humidity Sensors not supplied by MEUK

TG2000 Software with Third Party Equipment

Page 151: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PC Based Software Package used to monitor and control multiple sites

The TG2000 WAN centralised PC based graphical software package allows the operator to control and monitorup to a maximum of 1000 sites. Utilising the companies Wide Area Network, the complete (geographically distributed)air conditioning asset base can be controlled and monitored from a centralised location.

SITE 1(i.e. MANCHESTER)*NOTE 1

SITE 999(i.e. BIRMINGHAM)*NOTE 1

TG2000WAN (Wide Area Network) Software

OPERATING PLATFORM

MAX No. OF SITES

MAX No. OF INDOOR UNITS PER SITE

OPERATIONAL SECTIONS

ON/OFF

OPERATION MODE

SET TEMPERATURE

AIR SPEED

REMOTE CONTROLLER

PROHIBIT/PERMIT

ABNORMALITY (FAULT) MONITORING

ROOM TEMPERATURE MONITORING

SCHEDULED ON/OFF

GRAPHICAL SCREENS

THIRD PARTY EQUIPMENT MONITORING

THIRD PARTY EQUIPMENT CONTROL

EMAIL

FUNCTION

CPU 1000 Mhz, 512 MB RAM, 6GB or more. Internal LAN 10/100 MBps running Windows Professional 2000service pack 4 or Windows Professional XP service pack 2 or Windows Vista or Windows 7

1000

2000 Indoor units, 50 indoor units per AG150/GB50 (per site)

The software package is split into two distinctive areas, System and Controls setting. System Setting: Password protected, System Configuration and group/block organisation, printer setting. Controls Setting: Normal Operation,monitoring and control functions as described below. The software allows individual indoor units to be allocated to logical groups, represented within user definable graphics screens, allocated during the system configuration

Indicates the On/Off status of each group within the selected graphical screen or entire building

Indicates the operational mode (Cool, Heat, Fan, Dry, Auto) for each group on the selected graphical screen

Displays the set temperature for each group on the selected graphical screen. Also able to limit the set point range in both heating and cooling mode

Displays the current fan speed setting for each group on the selected graphical screen

Displays the current prohibit/permit status for each groups remote controller on the selected graphical screen

Individual indoor unit fault monitoring is recorded within the fault log for both viewing and printing. Fault monitoring can also be viewed via the fault log for all units associated with a particular graphical screen or the entire building. Faults can also be tracked and printed using date of failure, date of recovery and error code

Displays the return air temperature of the master indoor unit within a group

On/Off schedules can be set for each group, each graphical screen or the entire building

The complete system configurations can be allocated between multiple screens. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located

Monitor general equipment Run and Faults via the PAC-YG66DCA interface and Temperature and Humidity via the PAC-YG63MCA

Control general equipment On/Off via the PAC-YG66DCA

The following information may be sent regularly and automatically via email: energy monitoring data, energy saving data, trend logging data (temperatures etc) and fault code history

DESCRIPTION

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50NOTE 2: The TG2000 WAN cannot be utilised if the following site functions are required: energy charging, energy saving and trend logging.NOTE 3: Temperature and Humidity Sensors not supplied by MEUK

Technical Information

PAC-YG66DCA PAC-YG63MCA

EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

PAC-YG66DCA PAC-YG63MCA

EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

WAN

TG2000 WAN (Wide Area Network) Software

Page 291

Co

ntro

lsR

ange

Page 290

TG2000 ScreenshotsDisplay Whole

The 2000 indoor units status may be shown on one screen.

Display Block

Block may be set for each area. Settings may bechanged by one click of the mouse for each area.

Display Floor

AutoCAD drawing may be imported to TG2000 to display floor screens.

Remote Controller Settings

Click on any icons in the floor view to access the remote controller settings. Buttons on the local controllers may be locked (On/Off, Mode, Setpoint, Filter reset).

Daily, Weekly and Annual Scheduling

Scheduling may be set from the TG2000. A nightset back operation is available (HEAT, 12ºC).

Monitor Fault Codes

Faults with the unit address can be displayed underfault conditions.

Energy Monitoring (AG150 Energy PIN code)

TG2000 in conjunction with energy meters can monitor the energy consumption for each outdoor unit, indoor unit or area. The indoor unit run hours can also be displayed.

Energy Saving (AG150 Energy PIN code)

TG2000 offers different energy saving options including load shedding.

Icons available to suit model type installed

TG

2000 W

AN

Soft

war

e/

TG

2000 S

cree

nsh

ots

Page 152: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

BACnet® INTERFACEFUNCTION NETWORK VARIABLE POINT TYPE NOTES

Control

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Airflow Direction

Filter Sign

Monitor

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Airflow Direction

Fault Code

Filter Sign

Room Temperature

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

Horizontal - 60,80,100º swing

Normal/Reset

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

Horizontal - 60,80,100º swing

4 Character code - Indicates all unit alarms

-

-

Digital Input

Analogue Input

Analogue Input

Analogue Input

Digital Input

Analogue Input

Digital Input

Digital Output

Analogue Output

Analogue Output

Analogue Output

Digital Output

Analogue Output

Analogue Output

Digital Output

Analogue Output

ProconTM BAC-IP/50

BEMS BACnet®

Interface

To further enhance our complete open system network offering, we offer a BACnet® interface solution.Utilising the ASHRAE BACnet® standard, complete control and monitoring integration can be achieved with up to 50 air conditioning units.

BACnet® INTERFACEFUNCTION BAC-IP/50 COMPATIBLE WITH

MAX No. OFINDOOR UNITS

CENTRALISED CONTROLLERREQUIRED

POWER SUPPLY

COMPATIBILITY

BEMS CONNECTION

DIMENSIONS - mm (WxDxH)

50

Yes (AG150 or GB50)

24VAC 0.5A

City MultiMr Slim via PAC-SF81MAM Series via MAC-399IF

Ethernet via HUB

144x34x104

Andover Controls

York BMS

Siemens

Priva Building Intelligence

Delta Controls

Technical Information

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50

BAC-IP/50

ETHERNETPAC-SC51KUA

M-NET

*NOTE 1

Page 293

Co

ntro

lsR

ange

Page 292

BAC-HD150

BEMS BACnet®

Interface

To further enhance our complete open system network offering, we offer a BACnet® interface solution. Utilising the ASHRAE BACnet® standard, complete control and monitoring integration can be achieved with up to 50 air conditioning units.

Technical Information

BAC-HD150

BACnet® INTERFACEFUNCTION NETWORK VARIABLE POINT TYPE NOTES

Control

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Airflow Direction

Filter Sign

Monitor

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Airflow Direction

Fault Code

Filter Sign

Room Temperature

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

Horizontal - 60,80,100º swing

Normal/Reset

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

Horizontal - 60,80,100º swing

4 Character code - Indicates all unit alarms

-

-

BACnet® INTERFACEFUNCTION BAC-HD150 COMPATIBLE WITH

MAX No. OFINDOOR UNITS

CENTRALISED CONTROLLERREQUIRED

POWER SUPPLY

COMPATIBILITY

BEMS CONNECTION

DIMENSIONS - mm (WxDxH)

50

No

240VAC 3.2A

City MultiMr Slim via PAC-SF81MAM Series via MAC-399IF

Ethernet

250x97x266

Andover Controls

York BMS

Siemens

Priva Building Intelligence

Delta Controls

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50

Digital Input

Analogue Input

Analogue Input

Analogue Input

Digital Input

Analogue Input

Digital Input

Digital Output

Analogue Output

Analogue Output

Analogue Output

Digital Output

Analogue Output

Analogue Output

Digital Output

Analogue Output

BEM

S B

AC

net

®In

terf

aces

TCP / IP TCP / IP

Page 153: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

ProconTM BAC-A/50

BEMS BACnet® Mr Slim Interface

A new BACnet® Interface has been specially developed for the Mr Slim systems. The BAC-A/50 can control up to50 individual systems.

PAC-SK82SI

BAC-A/50

BACnet® MR SLIM INTERFACEFUNCTION NETWORK VARIABLE POINT TYPE NOTES

Control

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Filter Sign

Monitor

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Fault Code

Filter Sign

Room Temperature

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

Normal/Reset

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

4 Character code - Indicates all unit alarms

-

-

BACnet® MR SLIM INTERFACEFUNCTION BAC-A/50 COMPATIBLE WITH

MAX No. OFINDOOR UNITS

CENTRALISED CONTROLLERREQUIRED

POWER SUPPLY

COMPATIBILITY

BEMS CONNECTION

DIMENSIONS - mm (WxDxH)

Andover Controls

York BMS

Siemens

Priva Building Intelligence

Delta Controls

Technical Information

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50

Digital Input

Analogue Input

Analogue Input

Analogue Input

Digital Input

Digital Input

Digital Output

Analogue Output

Analogue Output

Analogue Output

Digital Output

Analogue Output

Digital Output

Analogue Output

Page 295

Co

ntro

lsR

ange

Page 294

50

No

240VAC 0.5A

Mr Slim via PAC-SK82SI

Ethernet

270x75x210

BEMS LonWorks® Interface

The Mitsubishi Electric LMAP continues to strengthen the ability of our products to interface with other third party building control systems using the globally recognised and accepted open network protocol Echelon LonWorks®.LonWorks® was introduced into the building services industry a number of years ago with the aim of establishing itself as the defacto communications standard. Many hundreds of products now exist that utilise the LonWorks®

protocol from complete systems like BEMS, lighting, power monitoring and security down to simple sensors and relay switches.

To ensure that our products can connect directly and easily with other LonWorks® products, the L-MAP02was designed utilising Echelon MIPS technology and was the first to provide data in the LonWorks®

SNVT (Standard Network Variable Type) format.

LMAP

LMAP

M-NET

Technical Information

LMAP LonWorks® INTERFACEFUNCTION NETWORK VARIABLE POINT TYPE NOTES

Control

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Filter Sign

Monitor

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Fault Code

Filter Sign

Room Temperature

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint (only available when using PAC-YT51CRA or PAR-21MAA)

Normal/Reset

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint (only available when using PAC-YT51CRA or PAR-21MAA)

4 Character code - Indicates all unit alarms

-

-

LMAP LonWorks® INTERFACEFUNCTION LMAP COMPATIBLE WITH

MAX No. OFINDOOR UNITS

CENTRALISED CONTROLLERREQUIRED

POWER SUPPLY

COMPATIBILITY

BEMS CONNECTION

DIMENSIONS - mm (WxDxH)

50

No

240VAC 0.5A

City MultiMr Slim via PAC-SF81MAM Series via MAC-399IF

LonWorks FTT-10

340x60x360

Honeywell

Johnson Controls

Realtime Control Systems (LTX51/LTX21 via VCI)

Smart Controls

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50

Digital Input

Analogue Input

Analogue Input

Analogue Input

Digital Input

Digital Input

Digital Output

Analogue Output

Analogue Output

Analogue Output

Digital Output

Analogue Output

Digital Output

Analogue Output

BEM

S B

AC

net

®M

r Sl

im Inte

rfac

e/

BEM

S Lo

nW

ork

s®In

terf

ace

TCP / IP

FTT-10

Page 154: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

MODBUS INTERFACE - OPERATIONAL INFORMATION

FUNCTION NETWORK VARIABLE POINT TYPE NOTES

Control

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Airflow Direction

Filter Sign

Monitor

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Airflow Direction

Fault Code

Filter Sign

Room Temperature

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

Horizontal - 60,80,100º swing

Normal/Reset

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

Horizontal - 60,80,100º swing

4 Character code - Indicates all unit alarms

-

-

Digital Input

Analogue Input

Analogue Input

Analogue Input

Digital Input

Analogue Input

Digital Input

Digital Output

Analogue Output

Analogue Output

Analogue Output

Digital Output

Analogue Output

Analogue Output

Digital Output

Analogue Output

BEMS Modbus Interface

To further complement the existing control and interface product ranges being offered by Mitsubishi Electric tosupport their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.

ProconTM MOD-IP/50

ETHERNETPAC-SC51KUA

M-NET

*NOTE 1

Modbus

MODBUS INTERFACEFUNCTION MOD-IP/50 COMPATIBLE WITH

MAX No. OFINDOOR UNITS

CENTRALISED CONTROLLERREQUIRED

POWER SUPPLY

COMPATIBILITY

BEMS CONNECTION

DIMENSIONS - mm (WxDxH)

50

Yes (AG150 or GB50)

240VAC 0.5A

City MultiMr Slim via PAC-SF81MAM Series via MAC-399IF

Serial RS232, RS485 or TCP / IP

144x34x104

Trend via Synapsys SXNC200

Cylon

Satchwell

Crestron (Home automation)

Invensys

Interactive Homes

North BT

Andover

Siemens

Technical Information

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50

Page 297

Co

ntro

lsR

ange

Page 296

BEMS Modbus Mr Slim Interface

To further complement the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.

ProconTM A32M

PAC-SK82SI

A32M

Modbus

MODBUS MR SLIM INTERFACE - OPERATIONAL INFORMATION

FUNCTION NETWORK VARIABLE POINT TYPE NOTES

Control

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Monitor

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Fault Code

Room Temperature

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC

Heating 17-28ºC

Auto 19-28ºC

Lo-Mi1-Mi2-Hi

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC

Heating 17-28ºC

Auto 19-28ºC

Lo-Mi1-Mi2-Hi

4 Character code - Indicates all unit alarms

-

MODBUS MR SLIM INTERFACEFUNCTION A32M COMPATIBLE WITH

MAX No. OFINDOOR UNITS

CENTRALISED CONTROLLERREQUIRED

POWER SUPPLY

COMPATIBILITY

BEMS CONNECTION

DIMENSIONS - mm (WxDxH)

32

No

240VAC 0.5A

Mr Slim via PAC-SK82SI

Serial RS232 or 485

270x75x210

Trend via Synapsys SXNC200

Cylon

Satchwell

Crestron (Home automation)

Invensys

Interactive Homes

North BT

Andover

Siemens

Technical Information

Digital Input

Analogue Input

Analogue Input

Analogue Input

Digital Output

Analogue Output

Analogue Output

Analogue Output

Analogue Output

Analogue Output

NOTE: Not available on SEZ / SLZ BEM

S M

odbus

Inte

rfac

e/

BEM

S M

odbus

Mr

Slim

Inte

rfac

e

RS232 / 485 or TCP / IP

RS232 / 485

Page 155: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

BEMS Modbus Splits Interface

To further complement the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the Modbus range has been developed to accommodate the typical end-user needs as experienced within the UK market.

ProconTM A1M

A1M

Modbus

MODBUS SPLITS INTERFACE - OPERATIONAL INFORMATION

FUNCTION NETWORK VARIABLE POINT TYPE NOTES

Control

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Monitor

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Fault Code

Room Temperature

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC

Heating 17-28ºC

Auto 19-28ºC

Lo-Mi1-Mi2-Hi

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC

Heating 17-28ºC

Auto 19-28ºC

Lo-Mi1-Mi2-Hi

4 Character code - Indicates all unit alarms

-

MODBUS SPLITS INTERFACEFUNCTION A1M COMPATIBLE WITH

MAX No. OFINDOOR UNITS

CENTRALISED CONTROLLERREQUIRED

COMPATIBILITY

BEMS CONNECTION

DIMENSIONS - mm (WxDxH)

1

No

M SeriesMr Slim

Serial RS485

72x27x50

Trend via Synapsys SXNC200

Cylon

Satchwell

Crestron (Home automation)

Invensys

Interactive Homes

North BT

Andover

Siemens

Technical Information

Digital Input

Analogue Input

Analogue Input

Analogue Input

Digital Output

Analogue Output

Analogue Output

Analogue Output

Analogue Output

Analogue Output

Page 299

Co

ntro

lsR

ange

Page 298

BEMS KNX-EIB Interfaces

To further complement the existing control and interface product ranges being offered by Mitsubishi Electric tosupport their air conditioning systems, the KNX-EIB range has been developed to accommodate the typical end-user needs as experienced within the UK market.

KNX-EIB-IP-15

KNX-EIB-IP-100

ProconTM KNX-EIB-IP-15/100

ETHERNET

PAC-SC51KUA

M-NET

KNX-EIB CITY MULTI INTERFACESFUNCTION KNX-EIB-IP-15 KNX-EIB-IP-100 COMPATIBLE WITH

MAX No. OFINDOOR UNITS

CENTRALISEDCONTROLLERREQUIRED

POWER SUPPLY

COMPATIBILITY

BEMS CONNECTION

DIMENSIONS - mm(WxDxH)

15

Yes (AG150 or GB50)

9 to 30VDC or 24VAC 0.5A

City MultiMr Slim via PAC-SF81MAM Series via MAC-399IF

Ethernet via HUB

107x58x105

100

Yes (AG150 or GB50)

9 to 30VDC or 24VAC 0.5A

City MultiMr Slim via PAC-SF81MAM Series via MAC-399IF

Ethernet via HUB

107x58x105

ABB

Intelligent Buildings

Nova Controls Ltd

Siemens

*NOTE 1

KNX-EIB

KNX-EIB CITY MULTI INTERFACE UNITS - OPERATIONAL INFORMATION

FUNCTION NETWORK VARIABLE POINT TYPE NOTES

Control

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Monitor

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Fault Code

Room Temperature

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC

Heating 17-28ºC

Auto 19-28ºC

Lo-Mi1-Mi2-Hi

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC

Heating 17-28ºC

Auto 19-28ºC

Lo-Mi1-Mi2-Hi

4 Character code - Indicates all unit alarms

-

Technical Information

Digital Input

Analogue Input

Analogue Input

Analogue Input

Digital Output

Analogue Output

Analogue Output

Analogue Output

Analogue Output

Analogue Output

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50 BEM

S M

odbus

Split

s In

terf

ace

/

BEM

S K

NX

-EIB

Inte

rfac

es

RS485

Page 156: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

BEMS KNX-EIB Splits Interface

To further complement the existing control and interface product ranges being offered by Mitsubishi Electric to support their air conditioning systems, the KNX-EIB range has been developed to accommodate the typical end-user needs as experienced within the UK market.

ProconTM KNX-EIB-A-1

KNX-EIB-A-1

KNX-EIB

KNX-EIB SPLITS INTERFACE - OPERATIONAL INFORMATION

FUNCTION NETWORK VARIABLE POINT TYPE NOTES

Control

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Monitor

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Fault Code

Room Temperature

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC

Heating 17-28ºC

Auto 19-28ºC

Lo-Mi1-Mi2-Hi

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC

Heating 17-28ºC

Auto 19-28ºC

Lo-Mi1-Mi2-Hi

4 Character code - Indicates all unit alarms

-

KNX-EIB SPLITS INTERFACEFUNCTION KNX-EIB-A-1 COMPATIBLE WITH

MAX No. OFINDOOR UNITS

CENTRALISED CONTROLLERREQUIRED

COMPATIBILITY

BEMS CONNECTION

DIMENSIONS - mm (WxDxH)

1

No

M SeriesMr Slim

KNX (TP-1) EIB

60x25x48

ABB

Intelligent Buildings

Nova Controls Ltd

Siemens

Technical Information

Digital Input

Analogue Input

Analogue Input

Analogue Input

Digital Output

Analogue Output

Analogue Output

Analogue Output

Analogue Output

Analogue Output

Page 301

Co

ntro

lsR

ange

Page 300

Technical Information

BEMS Trend Interface

Mitsubishi Electric and Synapsys Solutions have been working together for the last six years to offer very competitive solutions for Trend users. The IQ3 Excite Interface has been modified by Synapsys Solutions to work directly in conjunction with the AG150 and GB50 centralised controllers. This allows Trend users to easily integrate Trend systems with Mitsubishi Electric air conditioning.

IQ3 Excite

(must be supplied by Synapsys)

ETHERNET

PAC-SC51KUA

M-NET

*NOTE 1

Trend

IMPORTANT NOTE: The IQ3 Excite Interface can only be supported by Synapsys Solutions (Tel: 01273 831831)

TREND INTERFACESFUNCTION NETWORK VARIABLE POINT TYPE NOTES

Control

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Airflow Direction

Filter Sign

Monitor

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Airflow Direction

Fault Code

Filter Sign

Room Temperature

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

Horizontal - 60,80,100º swing

Normal/Reset

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

Horizontal - 60,80,100º swing

4 Character code - Indicates all unit alarms

-

-

Switch

Knob

Knob

Knob

Digital Input

Knob

Digital Input

Switch

Knob

Knob

Knob

Digital Output

Knob

Sensor

Digital Output

Sensor

*NOTE 1: Applicable with AG150 / PAC-SC51KUA or GB50

TREND INTERFACEFUNCTION IQ3 EXCITE COMPATIBLE WITH

MAX No. OF INDOOR UNITS

CENTRALISED CONTROLLERREQUIRED

POWER SUPPLY

COMPATIBILITY

BEMS CONNECTION

DIMENSIONS - mm (WxDxH)

50

Yes (AG150 or GB50)

240VAC

City MultiMr Slim via PAC-SF81MAM Series via MAC-399IF

Ethernet via HUB

263x42x130

Trend only

Trend IQ3 Excite

BEM

S K

NX

-EIB

Split

s In

terf

ace

/

BEM

S Tr

end Inte

rfac

e

Page 157: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

M2M INTERFACEFUNCTION DESCRIPTION

MAX No. OF INPUTS

MAX No. OF OUTPUTS

MAX No. OF INDOOR UNITS

SIM CARD

M2M SERVER HOSTING

POWER SUPPLY

COMPATIBILITY

DIMENSIONS - mm (WxDxH)

22 (4 to 20mA, 0 to 10VDC, 10kΩ resistor, digital)

4 (volt free contact)

12 (pulse with modulation)

50

Vodafone Sim Card supplied with one year contract

First year free of charge

240VAC 2A

City Multi, Mr Slim and M Series

300x70x350

M2M INTERFACE - OPERATIONAL INFORMATION FUNCTION NETWORK VARIABLE

Control

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Airflow Direction

Filter Sign

Monitor

On/Off

Mode Operation

Setpoint Adjustment

Fan Speed Control

Permit / Prohibit

Airflow Direction

Fault Code

Filter Sign

Room Temperature

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

Horizontal - 60,80,100º swing

Normal/Reset

Run/Stop

Cool / Dry / Heat / Auto / Fan

Cooling 19-30ºC, Heating 17-28ºC, Auto 19-28ºC

Lo-Mi1-Mi2-Hi

On/Off, Mode, Setpoint

Horizontal - 60,80,100º swing

4 Character code - Indicates all unit alarms

-

-

NOTESUP TO 25 GROUPS UP TO 50 GROUPS

M2M - Machine 2 Machine Interface

To offer remote management of its air conditioning units to companies with large numbers of dispersed offices, Mitsubishi Electric has adopted the M2M platform. The machine-to-machine (M2M) technology platformallows customers to integrate multiple sites into one network. The air conditioning units as well as third party equipment will be wirelessly connected to the M2M server and use the GPRS network to communicate.

MEUK

M2M SERVER

Technical Information

GPRS

Maxi M2M-IP/50

DEMONSTRATIONVisit m2m.mitsubishielectric.co.uk/demo to use the live demonstration space (login: demo / password: demo)

METER 1 METER 2 METER 3 METER 4 EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

Maxi M2M-IP/50

METER 1 METER 2 METER 3 METER 4 EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

Page 303

M2M

Inte

rfac

e /

M2M

Split

s In

terf

ace

Co

ntro

lsR

ange

Page 302

ProconTM Maxi M2M-IP/50

GB50ADA

GB50ADA

M2M SPLITS INTERFACEFUNCTION DESCRIPTION

MAX No. OF INPUTS

MAX No. OF OUTPUTS

MAX No. OF INDOOR UNITS

SIM CARD

M2M SERVER HOSTING

POWER SUPPLY

COMPATIBILITY

DIMENSIONS - mm (WxDxH)

8 (4 to 20mA, 0 to 10VDC, 10kΩ resistor, digital)

4 (pulse with modulation)

16

Vodafone Sim Card supplied with one year contract

First year free of charge

240VAC 2A

Mr Slim and M Series via Procon A1M

255x60x180

DEMONSTRATION

To offer remote management of its air conditioning unitsto companies with large numbers of dispersed offices, Mitsubishi Electric has adopted the M2M platform. The machine-to-machine (M2M) technology platformallows customers to integrate multiple sites into onenetwork. The air conditioning units as well as third party equipment will be wirelessly connected to the M2M server and use the GPRS network to communicate.

M2M SPLITS INTERFACE - OPERATIONAL INFORMATION FUNCTION NETWORK VARIABLE NOTES

ControlOn/Off Run/Stop

Mode Operation Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment Cooling 19-30˚C

Heating 17-28˚C

Auto 19-28˚C

Fan Speed Control Lo-Mi1-Mi2-Hi

Time Zone Weekly scheduling available

Monitor

On/Off Run/Stop

Mode Operation Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment Cooling 19-30˚C

Heating 17-28˚C

Auto 19-28˚C

Fan Speed Control Lo-Mi1-Mi2-Hi

Fault Code 4 Character code – Indicates all unit alarms

Room Temperature -

Time Zone Weekly scheduling available

Technical Information

MEUK

M2M SERVER

GPRS

A1MMini M2M-A/16

METER 1 METER 2 METER 3 METER 4 EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

Mini M2M-A/16

METER 1 METER 2 METER 3 METER 4 EQUIPMENT 1 EQUIPMENT 2 SENSOR 1 SENSOR 2

ProconTM Mini M2M-A/16

M2M - Machine 2 Machine Splits Interface

A1M

A1M A1M

Visit m2m.mitsubishielectric.co.uk/demo to use the live demonstration space (login: demo / password: demo)

DEMONSTRATION

Page 158: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

The Micro M2M can monitor and control up to 8 splits systems. The Micro M2M cannot be connected to the M2M server but can be monitored and controlled using text messages (SMS).

M2M SPLITS INTERFACE - OPERATIONAL INFORMATION FUNCTION NETWORK VARIABLE NOTES

ControlOn/Off Run/Stop

Mode Operation Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment Cooling 19-30˚C

Heating 17-28˚C

Auto 19-28˚C

Fan Speed Control Lo-Mi1-Mi2-Hi

Monitor

On/Off Run/Stop

Mode Operation Cool / Dry / Heat / Auto / Fan

Setpoint Adjustment Cooling 19-30˚C

Heating 17-28˚C

Auto 19-28˚C

Fan Speed Control Lo-Mi1-Mi2-Hi

Fault Code 4 Character code – Indicates all unit alarms

M2M SPLITS INTERFACEFUNCTION DESCRIPTION

MAX No. OF INDOOR UNITS

POWER SUPPLY

COMPATIBILITY

DIMENSIONS - mm (WxDxH)

8

10 to 28VDC 2.5A

Mr Slim and M Series via Procon A1M

70x51x105

TEXT MESSAGE EXAMPLES

REGISTER (FROM MOBILE PHONE)

MONITOR

CONTROL

FAULTS

ProconTM Micro M2M-SMS-A/08

M2M - Machine 2 Machine Splits Interface

SMS

Micro M2M-SMS-A/08

A1M A1M

A1M A1MMicro M2M-SMS-A/08

Technical Information

M2M

Split

s In

terf

ace

/ M

2M

Web

Scr

eensh

ots

Co

ntro

lsR

ange

To register the Micro M2M to your mobile phone, just text the PIN and “ADD”. Up to 8 numbers can beregistered. For example: “1234 ADD” 1234 being the last 4 digits of the serial number

To monitor the units, just text “STATUS” to the unit and the Micro M2M will reply with, for example:STATUS UNIT1: OK A1M COMMS: OK DRIVE:OFF ROOM TEMP:22 TEMP SETPOINT:20 MODE: AUTO FAN:HIGH

To switch the unit to heat mode, just text “SET” “unit name” and “HEAT” for example: “SET UNIT1 HEAT”

If the unit goes into fault, the Micro M2M will send a detailed text message, for example:STATUS UNIT1: FAULT A1M COMMS: FAULT CALL 0870 3000300 FOR ASSISTANCE

Page 305Page 304

M2M-Machine 2 Machine Web Screenshots

MEUK Website

M2M is accessible using MEUK website.

Login

A username and password is required to monitorand control sites.

Monitor Active Alarms and Sites

All sites are listed with active alarm sites.

Status

A site can be selected to monitor each system.

Set Parameters

Indoor unit and third party equipment can becontrolled from the Website.

Reports

Reports can be generated for analysis.

Dashboard

AG150/GB50 web pages are availablefor the air conditioning units

Administration

Using the administration level, the phone numbers and email of each duty engineer may be set and activated.

Technical Information

Page 159: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

PROCONTM PANEL_RS_SMS

MAX No. OF INDOOR UNITS

FEATURES

POWER SUPPLY

COMPATIBILITY

DIMENSIONS - mm (WxDxH)

8

Buzzer / Fault LED / Auto/Manual override switch / Relay for fault output

240VAC 2A

Mr Slim and M Series via Procon A1M

253x90x180

TEXT MESSAGE EXAMPLES

REGISTER (FROM MOBILE PHONE)

SET UP USING A TEXT

To register the Micro M2M to your mobile phone, just text the PIN and “ADD”. Up to 8 numbers can beregistered. For example: “1234 ADD” 1234 being the last 4 digits of the serial number

Enter the number of units running, the number of days to switch over and the high temperature alarm, forexample: “BACKUP ON, 3, 7, 27” (“ON” to activate, “3” for 3 units running, “7” to switch over every 7 daysand “27” for the high temperature alarm [all the units will be switch ON])

Technical Information

ProconTM PANEL_RS_SMS

Run Standby Panel

The panel PANEL_RS_SMS replaces the previous run standby panels. The new panel is smaller and uses Micro M2Mtechnology. The panel can control up to 8 indoor units and will send a text message under fault condition. The PANEL_RS_SMS does not need the SIM card to run.

SMS

A1M A1MProconTM

PANEL_RS_SMS

Example: “BACKUP ON, 2, 1, 27” = 2 units running, change daily, high temperature 27ºC

2 units running, unit 3 and 4 are in standby

2nd day, the switching over is enabled. Unit 1 and 4are now in standby and Unit 2 and 3 are running

3rd day, the switching over is enabled. Unit 1 and 2are now in standby and Unit 3 and 4 are running

On the 3rd day, the unit 4 fails

The next unit in standby starts automatically. Unit 1 and 3 are running, 2 is in standby and 4 in fault

The 4th day, a high temperature is detected for instance 28ºC

All units will then start

Day 1

Day 2

Day 3

Day 3

Day 3

Day 4

Day 4

Unit 1 Unit 2 Unit 3 Unit 4

NOTE: The PANEL_RS_SMS is pre-configured as a PANEL_RS1 and can be re-configured as PANEL_RS2 or PANEL_RS3 using a jumper.

FUNCTION DESCRIPTION

Page 307

Co

ntro

lsR

ange

Page 306

Split-System A2M InterfacesThe City Multi systems use advanced communication protocol called M-NET. The Split-Systems can be interfaced to M-NET, allowing compatibility with the main centralised controller (AG150, GB50, TG2000). An A2M adapter would be required per outdoor unit for Mr Slim and per indoor unit for Mr Slim S Series or M Series indoor units.

FUNCTION

COMPATIBILITY

CONNECTION TO

MNET SETTINGS

DIMENSIONS - mm (WxDxH)

Mr Slim S Series / M Series Indoor Unit

Indoor Unit

Dip Switches

160x55x70

PAC-SF81MA

SPLIT-SYSTEM A2M INTERFACES

Mr Slim Outdoor Unit

Outdoor Unit

Rotary Switches

130x15x90

MAC-399IF

Technical Information

PAC-SF81MA

Run S

tandby

Pan

el /

Sp

lit-S

yste

m A

2M

Inte

rfac

es

Page 160: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Mitsubishi Electric Partner Programme

Open to all contractors - large or small - the Mitsubishi Electric Partner Programme offers contractors

a totally new and unique set of benefits. There are two categories within the programme - Accredited

Installer and Business Solutions Partner. These levels are a straight-forward reflection of the Partner’s

stage of growth. All customers signing up to the programme standards are committing to continued

training and professional development.

For more information please contact your local sales office

Mitsubishi Electric Training Options

Mitsubishi Electric has four state-of-the-art training suites based at different

locations around the country for your convenience. Providing training for

all levels of expertise, our courses are taught by experienced engineers,

with a wealth of knowledge and are all CPD accredited.

For bookings please telephone 0161 866 6089

Many of our systems have an energy label of A. These systems meet the criteria of the

Energy Technology List and hence could qualify for 100% first year enhanced capital allowances

(whole system cost and ‘reasonable’ cost of installation). For further information please

go to www.eca.gov.uk

Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB.

Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB.

UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB.

UK Conditions: Winter ; indoor 21˚C DB; outdoor -1˚C WB.

Note: The fuse rating is only a typical value, it is the responsibility of a

qualified electrician/electrical engineer to select the correct cable size

and fuse rating based on current regulation and site specific conditions.

the name Mitsubishi is

synonymous with excellence

Known the world over, Mitsubishi is a trusted global leader

associated with a variety of products and services. Founded

in 1921, Mitsubishi Electric quickly rose to the forefront of the

air conditioning industry - a position we still enjoy today.

Unsurpassed air conditioning from Mitsubishi ElectricAir conditioning is an ideal way of controlling the internal environment of any building, large or

small. It does not only provide cooling when required, but also heating and often hot water can

be supplied from the same system. Providing heating and hot water as part of an integrated

air conditioning system is far more efficient than traditional heating methods such as gas and as a result

reduced running costs and emissions can be realised. More and more people are experiencing the

benefits of comfortable working, living and leisure environments made possible with air conditioning.

As market leaders, we pride ourselves in providing high performance, competitive systems with

low running costs and emissions.

Environmental AwarenessMitsubishi Electric boasts an explicit commitment to sustainable business practices such as energy

and resource efficiency, minimising ecological impacts and reducing greenhouse gas emissions. All of

our factories and UK operations are ISO14001 registered, the international standard that ensures

that we are fully aware of the environmental impact of all our processes and ensures we have

procedures in place to reduce them. However, we have gone far further than any accepted

minimum standards. Our ‘Environmental Vision 2021’ provides a vision for a lower emission future

that influences all our policy decisions. Our Green Gateway Initiative takes this vision even further

as it looks to install behavioural change in our own operations and our wider sphere of influence

with contractors, consultants and end users. It looks to highlight the advantages and opportunities

provided, by ensuring all of our activities are undertaken with consideration to the environment.

We are also proud to be a partner within Sustainable Energy Europe, whose stated aim is to raise

awareness of energy use in Europe.

The Forest Stewardship Council (FSC) is an international network promoting responsible

management of the world's forest. The paper this catalogue is printed on supports the

development of responsible forest management worldwide. The wood comes from FSC

certified, well managed forests, company controlled sources and/or recycled material.

www.green-gateway.co.uk

www.sustenergy.org

www.mitsubishielectric.com/eco

Nano Platinum filter - incorporates nanometre sized platinum-ceramic particles that generate stable antibacterial and deodourising effects

Low unit height - minimal intrusioninto occupied space

Double thermostat function - control the temp via a sensorin the controller or the unit (wired remote controllers only)

I-Save - Recalls the preferred (preset) temperaturevia a single button

Catechin filter - improves air quality and preventsthe spread of bacteria and viruses within the room

Air Cleaning filter - catches dust particles andcontaminates, helping to keep the air fresh

Anti-Allergy Enzyme filter - artificial enzymecatalyst on the filament catches allergens

Swing Vane Mode

Auto Vane Shutter - when unit is switched offthe vane automatically closes

Wide Swing - distributes air laterally by up to 150º

Long Airflow Mode - particularly suitable foruse in long, narrow spaces

Infra-red remote controller

Optimised rotary or scroll compressor

Econo Cool - allows set temperature to be raised by 2ºCwithout any loss of comfort and a 20% gain in energy efficiency

Inverter control - adjusts performance to economically matchthe demand for heating or cooling

Auto-Restart

Quiet operation

72 different airflow patterns - 2, 3 or 4 way discharge

High ceiling compatibility through wide flow air outlets

Auto-Changeover

Hot Start - draught prevention

Factory charged refrigerant up to 30m

Standard filter

Optional high efficiency filter

Plasma Duo filter system

Quick clean design

Drain lift pump as standard

Optional drain lift pump

High external static pressure

Optional high static fan motor

Fresh air knockout

Branch duct knockout

Ceiling soiling prevention

Replace Technology available

Refrigerant volume check function

I-See Sensor

Duty Standby Operation

Page 161: Mitsubishi Electric 2011 Air Conditioning Product Catalogue

Corporate SalesTel: 0870 3000 070

Fax: 0870 3000 080

ScotlandTel: 01506 444960

Fax: 01506 444961

ManchesterTel: 0161 866 6060

Fax: 0161 866 6081

BirminghamTel: 0121 741 2800

Fax: 0121 741 2801

BristolTel: 01454 202050

Fax: 01454 202900

IrelandTel: +353 (0)1 419 8800

Fax: +353 (0)1 419 8890

email: [email protected]

LeedsTel: 0870 3300 347

Fax: 0870 3300 348

London Central RegionTel: 0207 928 6810

Fax: 0207 928 6569

London North RegionTel: 01707 282480

Fax: 01707 282481

Sales Offices:

London South RegionTel: 01689 881030

Fax: 01689 881031

20

11

Air C

ond

itionin

g P

rod

uct C

ata

log

ue

After Sales Service: 0161 866 6089

email: [email protected]

web: www.mitsubishielectric.co.uk/aircon

UNITED KINGDOM Mitsubishi Electric Europe Living Environmental Systems Division

Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England

General Enquiries Telephone: 01707 282880 Fax: 01707 278881

IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland

Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531)

Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2011. Mitsubishi and Mitsubishi Electric

are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the

equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly

developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general

particulars and shall not form part of any contract. All goods are supplied subject to the Company’s General Conditions of Sale, a copy of

which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.

Printed in November 2010 SAP No. 237005

Designed by Square Bear Limited 01604 899099. Square Bear Limited are committed to using FSC certified paper and printers,

wherever possible. The sealant process used on this catalogue is environmentally friendly, recyclable and biodegradable.

Air Conditioning Commercial Heating

Domestic Heating Photovoltaics

Wor ld ofMaking a

Dif ference

The Renewable Solutions Provider

2011 Air ConditioningProduct Catalogue

Features Key