mixed digesters - build a biogas plant...mixed digesters may be either “hard top” or “soft...

19
MIXED DIGESTERS Iowa State Univ. Associate Professor Jeffery Lorimor Ag & Biosystems Department

Upload: others

Post on 26-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

MIXED DIGESTERS

Iowa State Univ. Associate Professor

Jeffery Lorimor

Ag & Biosystems Department

Page 2: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

Mixed Digesters � Completely Stirred Tank Reactor

(CSTR) � Continuous flow/stir process

� Sequencing Batch Reactor (SBR)� Batch reactor

� Feed � Stir � Settle � Decant

Page 3: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

Stirred Ag Reactors in the U.S.

� 15 mixed digesters* � 10 dairy � 3 swine � 1 caged layers � 1 ducks

*Per Agstar database Oct. 2002

Page 4: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

Mixed Digesters

� CSTR…HRT = SRT� Generally design for long detention times

� 20-30 days � Means relatively large volume required…more $$ � Theoretically fresh manure is discharged if mixing

is thorough

� SBR…HRT>SRT � HRT may be very short…days or even hours � SRT is very long…provides more thorough

digestion

Page 5: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

Mixed Digesters � Must have some type of mechanical

system for agitating the manure� Mechanical propellers

� Submerged motors � Exposed motors with shafts extending

into the manure

� Pumps � Recirculate liquid � Recirculate gas

Page 6: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

Manure Thickness

� Mixed reactors are good for manures too thin for plug flow and too thick for lagoons � Plug flow: 10 - 13% TS (dairy) � Lagoons: 0.1 – 2% TS (flush sys)� Mixed: 2 – 5% TS (swine)

Page 7: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

Manure Thickness

� Swine manure� Farrowing/gestation: 3.0-5.0% TS � Finishing houses: 4.0-9.0% TS

� May have to be diluted if too thick

� Dairy manure � Typically 10-13% undiluted

� Bedding may thicken it � Works best undiluted in plug flow digester � Sand and digesters don’t go together

Page 8: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

Construction

� Mixed digesters may be either “hard top” or “soft top”

� Shape can be rectangular or circular� Round designs may be easier to mix

� Rectangular don’t need special length/width ratio like plug flows

� Concrete or steel � Must be insulated in cold climates

Page 9: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

Mixing � Ideally mixing would be continuous� Keeps microbes into contact with

nutrients � Requires a lot of energy

� Periodic mixing � Digesters respond quickly after mixing

or feeding � Over-designed mixers provide safety

factor against solids settling

Page 10: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

Primary Concerns

� Additional mechanical equipment required for mixing � More $$ to construct � More maintenance/management

requirements

� Solids accumulation if mixing or discharge designa are inadequate

� Struvite accumulations� Foul pumps & pipes

Page 11: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

Heating

� Uniform heat is necessary throughout digester volume � Preheat not necessary or

advantageous as it is for plug flow � Mixing while feeding is good

management practice to rapidly warm incoming manure

Page 12: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

Iowa Mixed Digester

Stored digested manure

Reception & pump pit

Page 13: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

Iowa Mixed Digester

� Iowa swine digester � Mixed morning and

night for ~ 1 hour each time

� Fed in the morning during the mixing cycle

� Manually activated pumps to provide feed

Page 14: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

Performance

� Loading rate� Gal manure fed = 540,000 gal/mo.

� 18,000 gal/day � 3.6 gal/sow-day � 1.5 kg VS/M3-day

� 90 lb VS/1000 ft3 (~10X lagoon loading rate)

Page 15: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

Performance

Energy production�

� Biogas generated = 588,000 cu ft/mo.� 19,600 cu ft/day (70% methane) � 3.9 cu ft/sow-day

� Electricity = 24,500 Kwh/mo. � 816 kwh/day � 163 watt-hr/sow-day � 6.8 watts/sow

� Generator run time 80% first 6 months

Page 16: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

Average COD reduction for Iowa CSTR

Performance - COD

= 60%Chemical Oxygen Demand

0 10000 20000 30000 40000 50000 60000 70000 80000 90000

10/08

/'99

10/22

/'99

11/04

/'99

12/02

/'99

12/20

/'99

12/30

/'99

1/14/2

000

1/27/2

000

2/10/2

000

2/24/2

000

3/9/20

00

3/23/2

000

4/20/2

000

CO

D (

mg

O2/

l)

0

20

40

60

80

100

120

CO

D r

educ

tion

(%)

Raw

Digestor

% Reduction

Page 17: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

75% 86%

Nitrogen Change

0

5

10

15

20

25

30

Raw Digested

TK

N a

nd

NH

3-N

, lb

/Kg

al TKN

NH3 75% 86%

Performance – N Change

Page 18: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular
Page 19: MIXED DIGESTERS - Build a Biogas Plant...Mixed digesters may be either “hard top” or “soft top” Shape can be rectangular or circular Round designs may be easier to mix Rectangular

Summary – Mixed Digesters

� Useful for moderately thick manure� Use if manure’s not thick enough for plug flow

� Additional mechanical requirements � maintenance and good management very

critical � Iowa unit has been challenging to maintain

� Good COD & VS reductions � Odor concentrations are reduced � Manure is still not “releasable” quality