Chapter 1 System Information
1.1 About this manual 3
1.2 How to set up the parameter-I 3
1.3 How to set up the parameter –II 4
1.4 Resetting the standard product default 4
Chapter 2 System Setup
2.1 Interface selection 5
2.1.1 Keyboard emulation parameters setting 6
2.1.2 RS-232 communication setting 11
2.2 Scanning mode selection 16
2.3 Beeper tone selection 17
2.4 String Options (Prefix & Suffix) 18
2.5 Setup Insertion 19
Chapter 3 BarCode parameters setting
3.1 UPC-A 23
3.2 UPC-E 26
3.3 EA N-13 29
3.4 EA N-8 31
3.5 Code39 33
3.6 Codabar 36
3.7 Code93 40
3.8 Code128 42
3.9 Interleaved2 of 5 45
3.10 Industrial 2 of 5 47
3.11 Matrix 2 of 5 49
3.12 China Postage 51
3.13 MSI/Plessey 53
3.14 Code 32 55
3.15 Code 11 57
3.16 Te lepen 59
3.17 Function Key Emulation & Function Code & A ppendix 61 - 2 -
Chapter 1 - System Information
1.1 About this ma nual
This User's Guide provides detailed programming instructions. Barcode
scanners are factory programmed for t he most comm on com munication
setting. If you need to change these settings, programming is accomplished
by scanning the bar codes in this guide.
1.2 How to set up the parameter
Step 1: Scan the start configuration barcode
Star t Configuration
Step 2: Scan necessary la bel for parameters that meet your application
Step 3: Scan end configuration to save the changes
End Configuration
- 3 -
1.3 How to set up the parameter – II
Most of time the scanner only requests one read of parameters when
changing to new values. You will hear two beeps when you successfully
set t o the new values. But for some special parameters, m ultiple reads ar e
nee ded to complete the configuration. When use these special parameters.
In some cases, you might need to read one or m ore barcodes, such as:
Hexadecima l barcodes. For example: prefix, suffix, etc.
Numeric barcodes. For example: inter-character delay, max/min length
To complete the change of setting you will need to read the “Confirm”
bar code after you read the parameter. Below is the flow chart to ex pla in
two different configurations.
1.4 Resett ing the standard product default
If you aren’t sure what programming options are in your
scanner, or you’ve c hanged som e options and want the
factory settings restored, scan the Standard Product
Default Settings bar code be low.
Standard Product Defaults Setting - 4 -
Chapter 2 - System setup
2.1 Interfac e selection
The scanner is designed to switch easily fr om inter faces.
Remember to reset the interface before changing to PS/2 or RS232 cable .
No presetting is requested for USB interface. Scanning USB bar code after
the cable is c hanged and activating the scanner by plugging the USB cable
again. USB interface complies w ith HID keyboard which means the setting
of USB scanner is exactly the same like the default setting from keyboard.
Start configuration End configuration
ITEM OPTION
* KEYBOARD
Interface Selection
RS-232
USB
- 5 -
2.1.1 Keyboard emulation parameters setting
Start configuration End configuration
ITEM OPTION
*IBM AT
IBM XT
IBM PS/2 30-80
Device Selection for keyboard IBM 5550
Interface
PS/2 2 5,30
NEC 9801
Reserved 1
Reserved 2
- 6 -
Start configuration End configuration
ITEM OPTION
* USA
ITALIAN
SPANISH
FREN CH Language for Keyboard Interface
GERMAN
JAPA NESE
Multi-Language Support
Reserved 1
- 7 -
Start configuration End configuration
ITEM OPTION
* Disable Function Key
Enable
Emulate External Keyboard * Disable
Enable
* Disable
ALT Mode
Enable
NOTE : Emulate External Keyboard
Scan the barcode below if you do not have an external keyboard.
After scanning the Emulate External Keyboard bar code, you m ust
power cycle your computer.
- 8 -
Start configuration End configuration
ITEM OPTION
* Disable Caps Lock
Enable
* Disable
Num Lock
Enable
Inter Character Delay
(Default:00) Ref: Appendix(00—64H)
- 9 -
Start configuration End configuration
ITEM OPTION
None
* CR
Terminator
Tab
ESC
CR + LF
Block transm ission delay
(Default:00)Ref: Appendix(00—0 AH)
Keyboard Speed
(Default 00: high cloc k rate) Ref: Appendix (00—08H)
- 10 -
2.1.2 RS-23 2 communication setting
Start configuration End configuration
ITEM OPTION
1200bps
2400bps
4800bpsBaud Rate
* 9600 bps
1 9200bps
3 8400bps
7 Bits
Data Bits
* 8 Bits
- 11 -
Start configuration End configuration
ITEM OPTION
* 1 Stop Bits Stop Bits
2 St op Bits
* NONE
ODD
Parity
EVEN
Mark
Space
- 12 -
Start configuration End configuration
ITEM OPTION
Inter-character de lay
(Default:00)Ref: Appendix(00—64H)
Block transmission delay
(Default:00)Ref: Appendix (0 0-0AH)
Response delay
(Default:00)Ref: Appendix (0 0-0AH)
* None
RTS/CTS
HANSHAKING
ACK/NAK
Xon/Xoff
- 13 -
Start configuration End configuration
ITEM OPTION
None
* CR+LF
CR
Terminator
For RS-232
LF
Tab
STX/ETX
EOT
- 14 -
Start configuration End configuration
ITEM OPTION
* None
RTS/CTS Handshaking
ACK/NAK
Xon/Xoff
- 15 -
2.2 Scanning mode selection
Start configuration End configuration
ITEM OPTION
* Tr igger On/Good Read Off
Trigger On/Off
Continuous/Trigger Off
Continuous/Testing
Reading Mode
Continuous/Trigger on
Continuous /Auto power on
Flash
Flash / Auto Power On
- 16 -
2.3 Beeper tone selection
Start configuration End configuration
ITEM OPTION
Beep Tone
(Default:09H)Ref: Appendix (00-10H)
Beep Sound Duration
(Default:05H)
Ref: Appendix (00-10H)
* Enable
Power On Beeper
Disable
* ONBeeper
OFF
- 17 -
2.4 String Options (Prefix & Suffix)
This section descr ibes the alterations which can be made to t he format of
the transmitted data string. A prefix and suffix of maximum 10 direct
input may be included in front and at the end of scanned barcode.
Format
{Prefix} {Code ID} {Bar Code} {Suffix}
How to set up a prefix?
To configure “## “as prefix
(1) Scan Start Configuration barcode
(2) Scan Preamble bar code
(3) Scan ‘#” twice from FULL ASCII table
(4) Scan Confirm configuration barcode
(5) Scan End Configuration barcode.
How to set up a suffix?
To configure “$$” as suffix
(1) Star t configuration barcode
(2) Scan Postamble barcode
(3) Scan ‘$” twice from FULL ASCII table
(4) Scan Confirm c onfiguration barcode
(5) Scan End configuration bar code.
- 18 -
2.5 Setup Insertion
This section descr ibes how to setup the insertion of output.
NOTE :
Max. 10 charters can be inserted eac h time
Max. Insertion group is only two.
Insertion group (01 ) or (02) can be used in different kinds of
barcodes at the same time
- 19 -
Example:
:
To insert character “A” before the third digit(3 )
Make the decoded data: 12 A3456789
How to set up a character you want to insert
(1) Scan Start Configuration barcode
(2) Scan “G1 Insertion character”
(3) Scan “4” a nd “1” from FULL ASCII Table
(4) Scan Confirm c onfiguration barcode
(5) Scan End configuration barcode
How to set up position you wish to place the character
(6) Scan Start Configuration barcode
(7) Scan “G1 Character Position”
(8) Scan “0” a nd “3” from FULL ASCII Table (which pr esents the position)
(9) Scan Confirm c onfiguration barcode
(10) Scan End configuration barcode
How to set up inse rtion for code 39
Go to chapter 3.5 (code 39 )
(11) Scan Start Configuration barcode
(12) Scan “Insert group selection” bar code
(13) scan “0” and “1” from FULL A SCII Table
(which presents the group- 01 you just set up previously)
(14) Scan Confirm c onfiguration bar code
(15) Scan End configuration barcode
- 20 -
Start configuration End configuration
Confir m configuration
ITEM OPTION
Preamble
(Default:00) Ref: Appendix
Postamble
(Default:00) Ref: Appendix
G1 Insertion character
(Default:00) Ref: Appendix
G2 Insertion character
(Default:00) Ref: Appendix
G1 Character Position to be
inserted (Default:00 ) Ref: Appendix
G2 Character Position to be
inserted (Default:00 ) Ref: Appendix
- 21 -
Start configuration End configuration
ITEM OPTION
*DisableBar Code ID
Enable
* Read 1 Time
Accuracy
Read 2 T imes
Positive and negative bar code Bar equals high
* Bar equals low
- 22 -
Chapter 3 - BarCode parameters setting
How to set up a Code ID?
(1) Scan Start configuration bar code
(2) Go to the ASCII Table and scan label that represent the desired
characters to be inserted.
(3) Scan Confirm configuration bar code
(4) Scan End c onfiguration bar code.
Start configuration End configuration
Confir m configuration
3.1 UPC-A
ITEM OPTION
Disable
Read
* Enable
Code ID Setting
(Default : F ) Ref: Appendix (20-7EH)
- 23 -
Start configuration End configuration
ITEM OPTION
* Disable UPC-A Expand to EAN-13
Enable
Disable
Check Digit Send
* Enable
* Disable
Truncate L eading Zero
Enable
Truncate Leading
(Default:00) Ref: Appendix (00-0DH)
Truncate Ending
(Default:00) Ref: Appendix (00-0DH)
Insert group selection
Ref: Appendix(00—02H)
- 24 -
Start configuration End configuration
ITEM OPTION
* NONE
2 digits
Supplement digits
5 digits
2 or 5 digits
Auto-discriminate Supplement
- 25 -
3.2 UPC-E
Start configuration End configuration
ITEM OPTION
Disable
Read
* Enable
Code ID setting
(Default : G) Ref: Appendix (20-7EH)
- 26 -
Start configuration End configuration
ITEM OPTION
* Disable UPC-E Expand to UPC-A
Enable
Disable
Check Digit Send
* Enable
Truncate Leading
(Default:00) Ref: Appendix (00-08H)
Truncate Ending
(Default:00) Ref: Appendix (00 -08H)
Insert group selection
(Default:00) Ref: Appendix (00 -02H)
- 27 -
Start configuration End configuration
ITEM OPTION
Disable Truncate L eading Zero
* Enable
* None
2 digits
Supplement digits
5 digits
2 or 5 digits
Auto-discriminate Supplement
- 28 -
3.3 EAN-13
Start configuration End configuration
ITEM OPTION
Disable Read
* Enable
Code ID setting
(Default : H) Ref: Appendix (20-7EH)
Disable Check Digit Send
* Enable
Truncate Leading
(Defa ult : 0 0 )
Ref: Appendix (00-0DH)
Truncate Ending
(Defa ult : 0 0 )
Ref: Appendix (00-0DH)
- 29 -
Start configuration End configuration
ITEM OPTION
* None
2 digits
Supplement digits
5 digits
2 or 5 digits
Auto-discriminate Supplement
* Disable ISBN/ISSN Conversion
Enable
Insert group selection
(Defa ult : 0 0 ) Ref: Appendix (00 -02H)
- 30 -
3.4 EAN-8
Start configuration End configuration
ITEM OPTION
Disable
Read
* Enable
Code ID setting
(Default : I) Ref: Appendix (20-7EH)
Disable
Check Digit Send
* Enable
Truncate Leading
(Default : 00) Ref: Appendix (00-08H)
- 31 -
Start configuration End configuration
ITEM OPTION
Truncate Ending
(Default : 00) Ref: Appendix (00-08H)
* None
2 digits
Supplement digits
5 digits
2 or 5 digits
Auto-discriminate Supplement
Insert group selection
(Default : 00) Ref: Appendix (00-02H)
- 32 -
3.5 Code39
Start configuration End configuration
ITEM OPTION
Disable
Read
* Enable
Code ID setting
(Default : J) Ref: Appendix (20-7EH)
* Disable
Check-sum verification
Enable
Disable
Check-sum transmission
* Enable
- 33 -
Start configuration End configuration
ITEM OPTION
* Disable Append
Enable
Min. code length
(Default: 00) Ref: Appendix (00-32H)
Max. code length
(Default: 32H)Ref: Appendix (00-32H)
Format * Standard Code39
Code 39 Full ASCII
- 34 -
Start configuration End configuration
ITEM OPTION
* Disable Transm it Start/End Character
Enable
Truncate Leading
(Default: 00) Ref: Appendix (00-32H)
Truncate Ending
(Default: 00) Ref: Appendix (00-32H)
Insert group selection
(Default: 00) Ref: Appendix (00-02H)
- 35 -
3.6 Codabar
Start configuration End configuration
ITEM OPTION
Disable
Read
* Enable
Code ID setting
(Defa ult : K) Ref: Appendix (20-7EH)
- 36 -
Start configuration End configuration
ITEM OPTION
Disable Check-sum verification
* Enable
* Disable
Check-sum transmission
Enable
* Disable
Append
Enable
Truncate Leading
(Default:00) Ref: Appendix (00-7EH)
- 37 -
Start configuration End configuration
ITEM OPTION
Truncate Ending
(Default:00) Ref: Appendix (00-7EH)
* ABCD/ABCD
Start/End type
abcd/abcd
abcd/tn*e
* Disable Start/End transmission
Enable
Min. code length
(Default: 05) Ref: Appendix (00 -3CH)
- 38 -
Start configuration End configuration
ITEM OPTION
Max. code length
(Default: 3 CH) Ref: Appendix (00-3CH)
Insert group selection
(Default: 00) Ref: Appendix (00-02H)
- 39 -
3.7 Code93
Start configuration End configuration
ITEM OPTION
Disable
Read
* Enable
Code ID setting
(Default : L) Ref: Appendix (20-7EH)
Disable
Check-sum verification
* Enable
- 40 -
Start configuration End configuration
ITEM OPTION
* Disable Check-sum transmission
Enable
Min. code length
(Default: 00) Ref: Appendix (0-50H)
Max. code length
(Default: 50H)Ref: Appendix (0-50H)
Truncate Leading
(Default: 00) Ref: Appendix (00-7EH)
Truncate Ending
(Default: 00) Ref: Appendix (00-7EH)
Insert group selection
Ref: Appendix (00-02H)
- 41 -
3.8 Code 128
Start configuration End configuration
ITEM OPTION
Disable
Read
* Enable
Code ID setting
(Default : M) Ref: Appendix (20-7EH)
Disable
Check-sum verification
* Enable
- 42 -
Start configuration End configuration
ITEM OPTION
* Disable Check-sum transmission
Enable
* Disable
FNC2 Append
Enable
* Disable
UCC/EA N128
Enable
* Disable FNC1 transmission
Enable
- 43 -
Start configuration End configuration
ITEM OPTION
Truncate Leading
(Default: 00) Ref: Appendix (00-7 FH)
Truncate Ending
(Default: 00) Ref: Appendix (00-7 FH)
Min. code length
(Default: 00) Ref: Appendix (00-7 FH)
Max. code length
(Default: 7FH) Ref: Appendix (00-7 FH)
Insert group selection
(Default: 00) Ref: Appendix (00-02H)
- 44 -
3.9 Interleaved 2 of 5
Start configuration End configuration
ITEM OPTION
* Disable
Read
Enable
Code ID setting
(Default : N) Ref: Appendix (20-7EH)
* Disable
Check-sum verification
Enable
Disa ble
Check-sum transmission
* Enable
- 45 -
Start configuration End configuration
ITEM OPTION
Truncate Leading
(Default : 00) Ref: Appendix (00-7EH)
Truncate Ending
(Default : 00) Ref: Appendix (00-7EH)
Min. code length
(Default : 00) Ref: Appendix (00-7 FH)
Max. code length
(Default : 7FH) Ref: Appendix (00-7 FH)
Insert group selection
(Default : 00) Ref: Appendix (00-02H)
- 46 -
3.10 Industrial 2 of 5
Start configuration End configuration
ITEM OPTICON
* Disable
Read
Enable
Code ID setting
(Default : O) Ref: Appendix (20-7EH)
Min. code length
(Default : 00) Ref: Appendix (00-32H)
Max. code length
(Defa ult : 32H) Ref: Appendix (00-32H)
- 47 -
Start configuration End configuration
ITEM OPTION
Truncate Leading
(Default : 00) Ref: Appendix (00-32H)
Truncate Ending
(Default : 00) Ref: Appendix (00-32H)
* Disable
Check-sum verification
Enable
* Disable
Check-sum transmission
Enable
Insert group selection
(Default : 00) Ref: Appendix (00 -02H)
- 48 -
3.11 Matrix 2 of 5
Start configuration End configuration
ITEM OPTION
* Disable
Read
Enable
Code ID setting
(Defa ult : P)Ref: Appendix (20-7EH)
* Disable
Check-sum verification
Enable
- 49 -
Start configuration End configuration
ITEM OPTION
Disable Check-sum transmission
* Enable
Truncate Leading
(Default : 00) Ref: Appendix (00-50H)
Truncate Ending
(Default : 00) Ref: Appendix (00-50H)
Min. code length
(Default : 0B) Ref: Appendix (00-50H)
Max. code length
(Defa ult : 50H) Ref: Appendix (00-50H)
Insert group selection
(Default : 00) Ref: Appendix (00-02H)
- 50 -
3.12 CHINA POSTAL CODE
Start configuration End configuration
ITEM OPTION
* Disable
Read
Enable
Code ID setting
(Default : Q) Ref: Appendix (20-7EH)
* Disable
Check-sum verification
Enable
Disable
Check-sum transmission
* Enable
- 51 -
Start configuration End configuration
ITEM OPTION
Truncate Leading
(Default : 00) Ref: Appendix (00-50H)
Truncate Ending
(Default : 00) Ref: Appendix (00-50H)
Min.code length
(Default : 00) Ref: Appendix (00-50H)
Max.code length
(Defa ult : 50H) Ref: Appendix (00-50H)
Insert group selection
(Default : 00) Ref: Appendix (00-02H)
- 52 -
3.13 MSI/Plessey
Start configuration End configuration
ITEM OPTION
* Disable
Read
Enable
Code ID setting
(Default : R) Ref: Appendix (20-7EH)
* Disable
MOD 10
Check-sum verification
MOD 10/10
MOD 11/10
- 53 -
Start configuration End configuration
ITEM OPTION
DisableCheck-sum transmission
* Enable
Truncate Leading
(Default : 00) Ref: Appendix (00-3CH)
Truncate Ending
(Default : 00) Ref: Appendix (00-3CH)
Min. code length
(Default : 00) Ref: Appendix (00-3CH)
Max. code length
(Defa ult : 3CH) Ref: Appendix (00-3CH)
Insert group selection
(Default : 00) Ref: Appendix (00-02H)
- 54 -
3.14 CODE 32
Start configuration End configuration
ITEM OPTION
* Disable
Read
Enable
Code ID Setting
(Default:S) Ref: Appendix (20 -7EH)
DisableCheck-sum verification
* Enable
DisableCheck-sum transmission
* Enable
- 55 -
Start configuration End configuration
ITEM OPTION
Truncate L eading
(Default : 00) Ref: Appendix (00-0AH)
Truncate Ending
(Default : 00) Ref: Appendix (00-0AH)
Insert group selection
(Default : 00) Ref: Appendix (00-0 2H)
- 56 -
3.15 CODE 11
Start configuration End configuration
ITEM OPTION
* Disa ble
Read
Enable
Code ID setting
(Default:T)Ref: Appendix (20-7EH)
Disa ble Check-sum verification
* Enable
- 57 -
Start configuration End configuration
ITEM OPTION
* Disable Check-sum transmission
Enable
Truncate Leading
(Default : 00) Ref: Appendix (00-50H)
Truncate Ending
(Default : 00) Ref: Appendix (00-50H)
Min. code length
(Default : 00) Ref: Appendix (00-50H)
Max. code length
(Defa ult : 50H) Ref: Appendix (00-50H)
Insert group selection
(Default : 00) Ref: Appendix (00-02H)
- 58 -
3.16 Telepen
Start configuration End configuration
ITEM OPTION
* Disa ble
Read
Enable
Code ID setting
(Default: V ) Ref: Appendix (20-7EH)
Disable
Check-sum verification
* E nable
Only Num nic (ALPHA) Data Format
* Full ASCII
- 59 -
Start configuration End configuration
ITEM OPTION
* Disable Check-sum transmission
Enable
Truncate Leading
(Default : 00) Ref: Appendix (00-40H)
Truncate Ending
(Default : 00) Ref: Appendix (00-40H)
Min. code length
(Default : 00) Ref: Appendix (00-40H)
Max. code length
(Defa ult : 40H) Ref: Appendix (00-40H)
Insert group selection
(Default : 00) Ref: Appendix (00-02H)
- 60 -
3.17 Function Key Emulation
Start configuration End configuration
ITEM OPTION
* Disable Function Key
Enable
Code 3 9 format
Full ASCII Code 39
To sca n a function key barcode label, Full ASCII Code 39 m ust be enabling.
Please refer to Full ASCII Code 39 Table to produc e the function key
barcode la bel.
Function Code
UP($A) F1($Q)
DOWN($ B) F2($R)
LEFT($C) F3 ($S)
RIGHT($D) F4($T) - 61 -
PAGE UP($ E) F5($U)
PAGE DOWN($ F) F6($V)
BS($H) F7($W)
TAB($I) F8($X)
HOME($K) F9($Y)
END($L) F10($Z)
ENTER($M) ESC(%A)
INSERT($ N) F11(%B)
DELETE($O) F12(% C)
- 62 -
Dec Hex Char. Dec Hex Char.
0 00 NUL 32 20 SP
1 01 SOH 33 21 !
2 02 STX 34 22 “
3 03 ETX 35 23 #
4 04 EOT 36 24 $
5 05 ENQ 37 25 %
6 06 ACK 38 26 &
7 07 BEL 39 27 ‘
8 08 BS 40 28 (
9 09 HT 41 29 )
10 0A LF 42 2A *
11 0B VT 43 2B +
12 0C FF 44 2C ,
13 0D CR 45 2D -
14 0E SO 46 2E .
15 0F SI 47 2F /
16 10 DLE 48 30 0
17 11 DC1 49 31 1
18 12 DC2 50 32 2
19 13 DC3 51 33 3
20 14 DC4 52 34 4
21 15 NAK 53 35 5
22 16 SYN 54 36 6
23 17 ETB 55 37 7
24 18 CAN 56 38 8
25 19 EM 57 39 9
26 1A SUB 58 3A :
27 1B ESC 59 3B ;
28 1C FS 60 3C <
29 1D GS 61 3D =
30 1E RS 62 3E >
31 1F US 63 3F ? - 64 -
Dec Hex Char. Dec Hex Char.
64 40 @ 96 60 ‘
65 41 A 97 61 a
66 42 B 98 62 b
67 43 C 99 63 c
68 44 D 100 64 d
69 45 E 101 65 e
70 46 F 102 66 f
71 47 G 103 67 G
72 48 H 104 68 h
73 49 I 105 69 i
74 4A J 106 6A j
75 4B K 107 6B k
76 4C L 108 6C l
77 4D M 109 6D m
78 4E N 110 6E n
79 4F O 111 6F o
80 50 P 112 70 P
81 51 Q 113 71 q
82 52 R 114 72 r
83 53 S 115 73 s
84 54 T 116 74 t
85 55 U 117 75 u
86 56 V 118 76 v
87 57 W 119 77 w
88 58 X 120 78 x
89 59 Y 121 79 y
90 5A Z 122 7A z
91 5B [ 123 7B {
92 5C \ 124 7C |
93 5D } 125 7D }
94 5E ^ 126 7E ~
95 5F _ 127 7F DEL - 65 -
Function Key Table
0 1
0 NULL
1 UP F1
2 DOWN F2
3 LEFT F3
4 RIGHT F4
5 PAGE UP F5
6 PAGE DOWN F6
7 F7
8 BS F8
9 TAB F9
A F10
B HOME ESC
C END F11
D ENTER F12
E INSERT
F DELETE
- 67 -