mobile air sterilizer - b science global · this means that the unit actually decontaminates ......

8
Mobile Air Sterilizer

Upload: ngohanh

Post on 08-Apr-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

M o b i l e A i r S t e r i l i z e r

820mm

320mm

320mm

Mobi le Air Ster i l i zer

B Sciences Mobile Air Sterilizer device - works as a stand alone plug and play system - it has a complied sterilizer and a negative ion generator. One of the greatest specification of the device is its ability to absorbing the pathogens and harmful gases in the air while destorying bacteria, viruses, funges, molds and spores, etiological agents . This means that the unit actually decontaminates the area by generating photo catalysis reaction in its reactor.

The B Mobile Air Sterilizer has powerful air absorption system which takes the air from the bottom diffusers and provides air circulation.

In laboratories and hospitals it is a constant daily challange to keep a safe, clean and steril environment.

The flow of bacteria, molds, viruses, spores, funges, etiological agents, pathogens and harmful gases are a daily risk factor in the environment of laboratories and hospitals, the Mobile Air Sterilizer is a perfect add on/fit/helper, with its small design it does not take any space requirements and as a plug and play device you can place it almost anywhere.

It can run 24 hours a day, every day and doing working hours. The device is not harfulm to personal only helpful insuring a clean sterile environment.

The Mobile AIr Sterilizer brings the bacteria level and mold level within 24 hours down to almost 0 % in an area of 100m3.

HEPA H13 / Opt ional H14 Fi l ters• H13 filters with effiency of 99,95 % MPPS

• A design that provides an easy

procudere for filter replacement

• Optional HEPA H14 filter with effiency

of 99,995 % MPPS

UV-C L ight source

• 4 factory installed UV Lamps

• 254 nm for each UV lamp

• Each UV Lamp has a lifespan

of approx. 5000 hours

Construct ion des ign• Robust Cabinet construction

• External material are AISI 304 Stainless steel

Castor

• Comes with castor

• The castors are lockable

• Easy to place and relocate

Power Supply • Plug and Play connection with 220V,

1 Phase 50/60 H

Contro l ler with LED Screen

• Displayes all safety information

• Acustic alarm

• Password protected

• 3 different working modes

Motor/Fan

• Creates a negative pressure in the device

and a positive pressure outside the device

Pathogen Ion Generator

• Generates negative ions and Ozone (3)

• The generator are using HV, Titanium

dioxide (TiO2), Silver iodine (AgI),

Copper sulphate (CuS) coated borosilicate

to ionize

Pre-f i l ter G4 /EU4

• Cartridge type pre-filter

• Easy to changes

Serv ice and Maintenance• Easy to service and maintain

• All parts can be changes from the top

The cabinet a i r f i l t rat ion system

B Sciences Mobile Air Sterilizer device works as a stand alone system.

The Fan are creating a positive pressure outside the device and a negative pressure inside the device, the ambient air is pulled through the bottom of the device and then filtrated by the G4/EU4 pre-filter to reduce the ammount of particles in air.

The pre-filtrated air then flows through the Pathogen Ion generator and UV-C lights, where it is affected by HV, Titanium Dioxide(TiO2), Silver Iodide(AgI), Copper Sulphate(CuS) covered Borosilicate glass tupes and short wage light source and as a result of this process, the molecules of the intaken air are transformed to negative Ions, Ozone (O3) and free electrodes. It is thanks to this advanced technology, that our mobil air sterilizer are able to generate negative ions, oxygen and ozone gases which destroys odor and pollution.

The device combines ultraviolet (UV) light 254 nm radiation and bioactive hydroxyl radicals to make the air steril and hygienic by destroying bacteria, viruses, fungi, molds and spores, etiological agents. It especially helps to eliminate ethylene gases (C2H4) with corrosive effect to the environment.

To finalise the process and to eliminate that none of the neutralized microorganism are entering the room, the air are filtered through a HEPA H13 filter to collect the neutralized microorganism, leaving the exhauseted air decontaminated.

Display

• Displayes the operating mode • Shows if UV Lamps are turned On or Off • Shows if Ironizer are turned On or Off• UV Lifetime indicator• HEPA filter Lifetime indicator• Password protection

3 work ing Modes

• ECO Mode• Medium Mode • High Mode

Design Construct ion

• Plug and play• High quality material • Solid construction• External Material made of AISI 304 SS• Designed and manufactured in Denmark

Safety Features

• HEPA H13 filter (EN 1822) • G4/EU4 Pre-filter• Acustic alarm • Alarm for when UV Lamps needs to be changed • Alarm for when filters needs to be changed• Service Passwords• User Password

Easy Serv ice and Maintenance

• Easy access for service and maintenance • All components are easy to service and replace

Test Procedure: Samples are put in Sabouraud dextrose agar Bezier box for count of 1 m3 volume bacteria in the air, the procedure are done with air sampling instrument, choc-o-late agar and mold counting.

Samples have been taken before the Mobil Air Sterilizer has been swiched On. After the device has been swiched On, the samples has been taken in 2, 4, 6, 8 and 24 hour. After 72 hours incubition, the samples has been calculated and evalutated about 1 m3 volume bacteria in the air amendment rates of micro organism number as following:

Test Resul ts of 100 m3 from Microbio logy and Cl in ic Microbio logy laborator ie

HOURS REDUCTION OF TOTAL BACTERIA NUMBER

REDUCTION OF TOTAL MOLD NUMBER

0 960 2282 690 484 426 86 291 28 211 0

24 87 0

CHART 1: Regarding device working time, reduction of total number of bacteria and reduction of total number of mold.

CHART 2: Regarding device working time, reduction of total number of bacteria in procentage and reduction of total number of mold in procentage.

HOURS REDUCTION OF TOTAL BACTERIA NUMBER

REDUCTION OF TOTAL MOLD NUMBER

0 0 % 0 %2 28,1 % 79 %4 55,6 % 96,5 %6 69,7 % 99,1 %8 77,4 % 100 %

24 90,9 % 100 %

TECHNICAL SPECIFICATIONS

MODEL TYPE

MAS100

EXTERNAL DIMENSION (mm))

Width 320 Depth 320

Heigth 850

MAIN HEPA FILTER (H13)

Main Filter 99,95% MMPS

Main Filter Size (mm)

240x240x150

PRE-FILTER (G4 / EU4)

Pre-filter 90% MMPS

Pre-filter Size (mm)

250x250x20

UV-C Lamp (W) 15

VOLTAGE 220 V 50 - 60HZ

WEIGHT (KG) 22,5

* Transport height are below 2000mm

We reserve the right to change specifications without notice. Subject to confirmation, availability and errors.

Bavnevej 106580 VamdrupDenmark

+45 287 287 62

[email protected]

Danish Manufacture of Lab Equipment

C O N T A C T S

B Science´s certificates