mobile tester report - danske solcelleejere › wp-content › uploads › 2015 › 10 ›...
TRANSCRIPT
![Page 1: Mobile Tester Report - Danske solcelleejere › wp-content › uploads › 2015 › 10 › Effek… · EL details for 668111210252051 EL Image of Cell (2/3) kritisch:](https://reader033.vdocument.in/reader033/viewer/2022060414/5f12a348bc86d46691255702/html5/thumbnails/1.jpg)
Summary
Module ID: 668111210252051Manufacturer: AmerisolarModule Type/Description: AS-6M30-250WTestcenter Serial: 2007_FrankaModule Judgement: CLASSC
Job ID: 2015-10-05 BjerringbroAddress: Michael Hvitfeldt / Mikkelsgade 16Country / City: DK 8850 Bjerringbro
PowerPmpp @ STC IEC60891: 239.1WPower missmatch: -4.4% to 250.0W ( 0.0%->+3.0% )Tmod / Tref: 14.0C / 19.8CFlash Time: 93.5msFlasher Parameter: C14200N/Mono/175sOperator / Date Time: André Brunk 10/5/2015 4:05 PM
Connection CheckStatus: Successfull 8.7A 42.2V
ElectroluminescenceCell Judgement Count: 0 sehr kritisch: >=20% Zellfläche betr.
3 kritisch: <20% Zellfläche betr.4 unkritisch: keine Zellfläche betr.0 andere EL Auffälligkeiten
No Judgment Count: 53EL Parameter: 8.0s / 44.6V / 13.1A / Cell / AssistedOperator / Date Time: André Brunk 10/5/2015 4:05 PMReviewer / Date Time: André Brunk 10/5/2015 4:07 PM
CommentOperator / Date Time: André Brunk 10/5/2015 4:06 PM
Modul13
MBJ Services test report generated by mobile PV test center (2007_Franka) on 10/5/2015 at 4:07 PM. 1
![Page 2: Mobile Tester Report - Danske solcelleejere › wp-content › uploads › 2015 › 10 › Effek… · EL details for 668111210252051 EL Image of Cell (2/3) kritisch:](https://reader033.vdocument.in/reader033/viewer/2022060414/5f12a348bc86d46691255702/html5/thumbnails/2.jpg)
Power
Module ID: 668111210252051Type ID: Amerisolar / AS-6M30-250W
Pmpp[W] Impp[A] Umpp[V] Isc[A] Uoc[V] Irr[W/m2] FF[%]IEC60891 STC 239.1 8.02 29.81 8.59 37.22 1000.0 74.8Measured 216.9 6.92 31.35 7.50 38.28 922.0 75.5
Tmod[C]:14.0 Tref[C]:19.8 Tdev[C]:20.1 Tout[C]:16.6 T[ms]:93.5Type:Mono alpha[%]:0.056 beta[%]:-0.330 IEC aICF:0.060 IEC Rs:0.54Software:365p
MBJ Services test report generated by mobile PV test center (2007_Franka) on 10/5/2015 at 4:07 PM. 2
![Page 3: Mobile Tester Report - Danske solcelleejere › wp-content › uploads › 2015 › 10 › Effek… · EL details for 668111210252051 EL Image of Cell (2/3) kritisch:](https://reader033.vdocument.in/reader033/viewer/2022060414/5f12a348bc86d46691255702/html5/thumbnails/3.jpg)
Electroluminescence for 668111210252051
Current/A: 13.097 Voltage/V: 44.591Exposure Time [ms]: 8000 André Brunk 10/5/2015 4:05 PM
MBJ Services test report generated by mobile PV test center (2007_Franka) on 10/5/2015 at 4:07 PM. 3
![Page 4: Mobile Tester Report - Danske solcelleejere › wp-content › uploads › 2015 › 10 › Effek… · EL details for 668111210252051 EL Image of Cell (2/3) kritisch:](https://reader033.vdocument.in/reader033/viewer/2022060414/5f12a348bc86d46691255702/html5/thumbnails/4.jpg)
EL details for 668111210252051
EL Image of Cell (2/3)
kritisch: <20% Zellfläche betr.EL Image of Cell (2/4)
unkritisch: keine Zellfläche betr.
MBJ Services test report generated by mobile PV test center (2007_Franka) on 10/5/2015 at 4:07 PM. 4
![Page 5: Mobile Tester Report - Danske solcelleejere › wp-content › uploads › 2015 › 10 › Effek… · EL details for 668111210252051 EL Image of Cell (2/3) kritisch:](https://reader033.vdocument.in/reader033/viewer/2022060414/5f12a348bc86d46691255702/html5/thumbnails/5.jpg)
EL details for 668111210252051
EL Image of Cell (3/2)
kritisch: <20% Zellfläche betr.EL Image of Cell (4/2)
unkritisch: keine Zellfläche betr.
MBJ Services test report generated by mobile PV test center (2007_Franka) on 10/5/2015 at 4:07 PM. 5
![Page 6: Mobile Tester Report - Danske solcelleejere › wp-content › uploads › 2015 › 10 › Effek… · EL details for 668111210252051 EL Image of Cell (2/3) kritisch:](https://reader033.vdocument.in/reader033/viewer/2022060414/5f12a348bc86d46691255702/html5/thumbnails/6.jpg)
EL details for 668111210252051
EL Image of Cell (4/4)
unkritisch: keine Zellfläche betr.EL Image of Cell (5/9)
kritisch: <20% Zellfläche betr.
MBJ Services test report generated by mobile PV test center (2007_Franka) on 10/5/2015 at 4:07 PM. 6
![Page 7: Mobile Tester Report - Danske solcelleejere › wp-content › uploads › 2015 › 10 › Effek… · EL details for 668111210252051 EL Image of Cell (2/3) kritisch:](https://reader033.vdocument.in/reader033/viewer/2022060414/5f12a348bc86d46691255702/html5/thumbnails/7.jpg)
EL details for 668111210252051
EL Image of Cell (6/8)
unkritisch: keine Zellfläche betr.
MBJ Services test report generated by mobile PV test center (2007_Franka) on 10/5/2015 at 4:07 PM. 7