model 20 series 2012 panel y tarjetas

Upload: juliocanel2009

Post on 04-Apr-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/30/2019 Model 20 Series 2012 Panel y Tarjetas

    1/6

    PO Box 8067The Woodlands, TX 77387

    888-367-4286 (toll free)281-367-4100281-292-2860 (fax)[email protected]

    detcon inc.

    www.detcon.comCe r t i f i e d

    Catalog #12-0105

    Gas Detection Alarm & Control SystemsSingLE Sensor Control Card

    detcondetcon

  • 7/30/2019 Model 20 Series 2012 Panel y Tarjetas

    2/6

    DescriptionDetcon Model Series 12 gas detection and alarm systems consist of single sensor control cards that can

    be integrated into one system design to create multi-function monitoring and control of a wide range of fielddevices. Field devices include gas detection sensors, flame and fire detection devices and process sensors. Eachcontrol card is capable of supervising a single field device, displaying the current status of that device andproviding alarm relay outputs once user-configured limits are detected. Gas detection control modules displaythe real time concentration of a wide range of toxic gases, combustible gas, and oxygen sensors that output a4-20 milliamp signal. The flame detection module displays the real time status of any flame detector with a 4-20 milliamp output signal. The alarm annunciator module can be used to monitor smoke and thermal detectors,pull stations, and dry contact closure devices.

    Model Series 12 single sensor control cards feature four alarm relays. Three relays are used as active alarm controloutputs and the fourth relay is a fault condition relay. Each alarm relay is adjustable in single digit increments

    across the range of sensitivity. Alarm relays can be user-configured as latching, non-latching, normally energizedor normally de-energized via simple onboard programming jumpers. Front panel indicators include alarm statusLEDs and a 7-segment LED digital display of the real time concentration of a field device when applicable. Eachmodule is addressable via RS-485 serial communication.

    Detcon manufactures a variety of pre-engineered Model 12 Series mainframe hardware assemblies includingNEMA 1 panel mount, standard 19 rack mount, NEMA 4X weather-proof and NEMA 7 explosion-proof.Engineering services for high density integrated fire, gas and process control systems are available from the factory.

    Typical ApplicationsOil and Gas Drilling and Production

    Oil and Gas Treating PlantsRefining Chemical and Petrochemical PlantsAutomotive IndustryFood and Beverage ProcessingPower Generation PlantsPulp and Paper MillsUnderground MiningWater and Wastewater Treatment

    PressureTemperatureHumidityFlowLevel

    Combustible GasCatalytic & Infrared

    Monitoring and Control Options

    Gas Detection Sensor Technology

    Hydrogen Sulfide GasSolid State MOS & Electrochemical

    Toxic GasElectrochemical & Photo Ionization

    Oxygen Deficiency/EnrichmentAir Battery Electrochemical

    Process Controls

    Safety Controls

    IntrusionThermalSmokeFlame

  • 7/30/2019 Model 20 Series 2012 Panel y Tarjetas

    3/6

    natomy of a Model 12 Series

    Locking HardwareSecures modular Model 12 tcontrol enclosure card cage

    Design Features

    Modular Front Panel Plug-in DesignStandard Outputs: 4-20mA, RS-485 ModbusProgrammable Relay Outputs: 3 Alarms plus FaultControl Module Status Accessible via RS-485Alarm Reset & Alarm SilenceAlarm Disable for Calibration

    Full Diagnostics for Sensor Inputs & Field WiringTest Function Simulation for Verifying OperationFive Year Fixed-Fee Service Policy

    Single Sensor Control Cards

    4 to 12 Channel PackagingMotherboard has External Common Reset SwitchRelays Programmable for Discrete, Common or Zoned

    Control Enclosures

    Color Banding Label

    Yellow-H2S, Orange-LEL, Blue-Toxic, Green-O2, Red-Flame

    LED IndicatorFlashes in Over-range

    Alarm & Fault LEDs

    Alarm Reset Switch

    Test SwitchDisplays Alarm Set Points,RS-485 ID, Activates Test Fu

    Actual Size

    LEL

    Toxic

    Flame

    O2

    Alarm Set PointsAlarms 1, 2, and 3 are rotary switch programma-ble in single digit increments.

    Alarm RelaysProvide discrete, jumper programmable, nor-mally open or normally closed contacts. Jump-er programmable for normally energized ornormally de-energized.

    AlAn

    Alarm Disable Switch

    Addressable RS-485Set RS-485 ID

    Alarms 1, 2, & 3Jumper programmable to operate as ascendingor descending alarms. All alarms are jumperprogrammable for latching or non-latching.

  • 7/30/2019 Model 20 Series 2012 Panel y Tarjetas

    4/6

    re-Engineered System Packaging

    NEMA-1 Panel andRack Mount Assemblies

    Detcon Model 12 single sensor control cards can be used with a number of pre-engineered systempackages consisting of mainframe hardware assemblies that accommodate from 4 up to 12 control cards. Eachmainframe hardware assembly consists of a ruggedly constructed card cage, and motherboard with all I/O terminalstrips and alarm zoning jumpers.

    NEMA 4XWeatherproof Enclosures

    NEMA 7X WeatherproofExplosion Proof Enclosures

    Model 612-N1

    Model 1212-N1

    Model 812-N4X

    Model 412-N4X

    Model 1212-

    Model 612SS-N4X

    Model 412-N7

    roject Specific Engineered SystemsHardwire & PLC based SystemsAddressable & PC MMI SystemsField device selection and locationInstallation drawings and details

    Cabinet design and manufactureSystem start-up, training & after sale support

  • 7/30/2019 Model 20 Series 2012 Panel y Tarjetas

    5/6

    4-20 mA and Alarms

    nstallation & Integration Options

    Remote Display Capabilities

    Model 12 Series control systems integrate directly with hardwire 4-20 mA inputs from field devices. All modelsoffer discrete relay outputs for each sensor and provide the ability for relays to be set up as zoned or common. TheRS-485 serial output can be connected to any DCS, PLC or SCADA host control device. The RS-485 serial outputis also used to drive optional remote Read-Only Displays. Typical integration configurations are shown below.

    Serial Networking

    Ethernet

    PC withWeb Browser

    RS-232,RS-485,Ethernet

    PCMMI

    RS-485

    4-20 mADetcon

    Alarm Station

    Relays

    Model 612-N1

    DetconAlarm Station

    DetconAlarm Station

    Model 880 PLC ControllerModel

    812-N4X

    Relays

    4-20 mA

    Model1212-N4X

    Model812-N4X

    Model812-N4X

    Model812-N4X

  • 7/30/2019 Model 20 Series 2012 Panel y Tarjetas

    6/6

    rdering Information

    Detcon Inc. warrants each new Model12 Control Card and Control Enclosureto be free from defects in material andworkmanship under intended normaluse for a period of two years from thedate of shipment to the original pur-chaser. All warranties are FOB theDetcon factory located in The Wood-lands, Texas, USA.

    Warranty

    SpecificationsModel 12 - Single Sensor Control Cards

    NEMA 1 Rack/Panel Mount EnclosuresModel Number Description612-N1-24VDC 6 Channel (requires external 24 VDC power supply)1212-N1-24VDC 12 Channel (requires external 24 VDC power supply)

    NEMA 4 Weatherproof Enclosures412-N4X 4 Channel with Line Power Supply (in fiberglass enclosure)

    812-N4X 8 Channel with Line Power Supply (in fiberglass enclosure)1212-N4X 12 Channel with Line Power Supply (in fiberglass enclosure)612SS-N4X 6 Channel with Line Power Supply (in stainless steel enclosure)1212SS-N4X 12 Channel with Line Power Supply (in stainless steel enclosure)

    AccessoriesDescription Part No.Model 12 Blank Plate 912-000008-005PS -172 Rack Mount Power Supply (24 VDC, 172 Watt) 975-124172-110PS -288 Rack Mount Power Supply (24 VDC, 288 Watt) 975-124288-110

    NEMA 7 Hazardous Environment EnclosuresContact the factory for NEMA 7 enclosure specifications and availability.

    Range

    Ranges can be set from 1 ppm/% up to

    1000 ppm/% (in increments of 1 ppm/%)Accuracy/Repeatablity

    2% F.S.

    Operating Temperature Range

    -40F to +167F; -40C to +75C

    Input Voltage

    24 VDC standard, 12 VDC optional

    Power Consumption (per channel)