model 7000xtr high flow rate control valvextr+valve+spec.pdfmodel 7000xtr high flow rate control...

1
Model 7000XTR High Flow Rate Control Valve Part No. 42730 Rev A 5/08 Front (without cover) t The residential 7000XTR offers a two-line, sixteen character LCD backlit display for easy entering of master, diagnostic, and user programming. No need to memorize codes or letters to program or read screens! Time of day is maintained during power failures, offering peace of mind and steady, treated water as needed. Features • Shift key: Allows digit selection in user and master programming modes • Diagnostics - Current flow rate - Peak flow rate (can be reset) - Totalizer (can be reset) - Hours between last two regenerations - Hours since last regeneration - Volume remaining (adjustable) - Software version • User programming mode • Master programming mode • Programmable auxiliary relay output - Dry contact relay - Program entire regeneration - Program during cycle position • LED status indicator - Blue: In service - Green: In regeneration - Red: Error • Up to 35 GPM flows for residential/commercial softening and filtration applications • Reliable optical electronics eliminate microswitch positioning • Electronic timer provides quick setup and programming • Quick-connect clips allow easy installation and maintenance • Regenerates up to 10 cu. ft. softeners Options • High-flow bypass valve • High-flow distribution system • Plumbing connections in 3/4"-1-1/2" NPT, BSP and Sweat •Soft water brine refill • Variable reserve • Meter delayed, immediate, or time clock regeneration • Double backwash • Environmental cover (NEMA-3R rated) •Auxiliary switch • Filter or softener control valves Back (without cover) t Valve Specifications Valve material Fiber-reinforced polymer Inlet/Outlet 1" or 1-1/4" NPT or BSP, 1", 1-1/4", 1-1/2" Sweat Cycles Up to 6 cycles Flow Rates (50 psi Inlet) - Valve Alone Piston Standard High Flow Filter Continuous 28 36 37 Peak (25 psi drop) 36 46 47 Cv (flow at 1 psi drop) 7-1/10 9-1/5 9-1/2 Max. backwash (25 psi drop) 7 16 31 Regeneration Downflow/Upflow Downflow only Adjustable cycles Yes Time available Up to 240 minutes per cycle Meter Information Meter accuracy +5/-8% (2 - 40 gpm) Meter capacity range (gal.) 1,000 - 9,900,000 Dimensions Distributor pilot 1-1/20" O.D. or 32 mm O.D. Drain line 3/4" or 1" NPT Quick Connect Injector brine system 1610 Brine line 3/8" or 1/2" Quick Connect Mounting base 2-1/2" - 8" NPSM Height from top of tank 8" Typical Applications Water softener 8" - 24" diameter Filters 8" - 24" diameter Additional Information Electrical rating 24 VAC, 50/60 Hz Max. VA 15 Estimated shipping weight 11 lbs. Pressure Hydrostatic: 300 psi Working: 20 - 125 psi Temperature 34 o - 110 o F

Upload: duongque

Post on 30-Mar-2018

215 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Model 7000XTR High Flow Rate Control ValveXTR+VALVE+SPEC.pdfModel 7000XTR High Flow Rate Control Valve ... •Soft water brine refill • Variable reserve ... Cycles Up to 6 cycles

Model 7000XTR High Flow Rate Control ValveP

art N

o. 4

2730

Rev

A 5

/08

Front (without cover)

t

The residential 7000XTR offers a two-line, sixteen character LCD backlit display for easy entering of master, diagnostic, and user programming. No need to memorize codes or letters to program or read screens! Time of day is maintained during power failures, offering peace of mind and steady, treated water as needed.

Features •Shiftkey:Allowsdigitselectioninuserandmaster programming modes •Diagnostics -Currentflowrate -Peakflowrate(canbereset) -Totalizer(canbereset) - Hours between last two regenerations - Hours since last regeneration -Volumeremaining(adjustable) -Softwareversion •Userprogrammingmode •Masterprogrammingmode •Programmableauxiliaryrelayoutput - Dry contact relay - Program entire regeneration - Program during cycle position •LEDstatusindicator -Blue:Inservice -Green:Inregeneration -Red:Error •Upto35GPMflowsforresidential/commercialsofteningand filtrationapplications •Reliableopticalelectronicseliminatemicroswitchpositioning •Electronictimerprovidesquicksetupandprogramming •Quick-connectclipsalloweasyinstallationandmaintenance •Regeneratesupto10cu.ft.softeners

Options •High-flowbypassvalve •High-flowdistributionsystem •Plumbingconnectionsin3/4"-1-1/2"NPT,BSPandSweat •Softwaterbrinerefill •Variablereserve •Meterdelayed,immediate,ortimeclockregeneration •Doublebackwash •Environmentalcover(NEMA-3Rrated) •Auxiliaryswitch •Filterorsoftenercontrolvalves

Back (without cover)t

Valve SpecificationsValve material Fiber-reinforcedpolymer

Inlet/Outlet 1"or1-1/4"NPTorBSP,1",1-1/4",1-1/2"Sweat

Cycles Upto6cycles

Flow Rates (50 psi Inlet) - Valve AlonePiston Standard HighFlow FilterContinuous 28 36 37Peak(25psidrop) 36 46 47Cv(flowat1psidrop) 7-1/10 9-1/5 9-1/2Max.backwash(25psidrop) 7 16 31

RegenerationDownflow/Upflow Downflow onlyAdjustablecycles YesTime available Upto240minutespercycle

Meter InformationMeteraccuracy +5/-8%(2-40gpm)Metercapacityrange(gal.) 1,000-9,900,000

DimensionsDistributor pilot 1-1/20"O.D.or32mmO.D.Drain line 3/4"or1"NPTQuickConnectInjectorbrinesystem 1610Brine line 3/8"or1/2"QuickConnectMountingbase 2-1/2"-8"NPSMHeight from top of tank 8"

Typical ApplicationsWater softener 8"-24"diameterFilters 8"-24"diameter

Additional InformationElectricalrating 24VAC,50/60HzMax.VA 15Estimatedshippingweight 11lbs.

Pressure Hydrostatic:300psiWorking:20-125psi

Temperature 34o-110oF