model gsw80 deutz & 110 perkins. - pratec · • engine temperature (depending on model) ouput...

6
Business Units GENERATORS Product Cards GSW65-80P(50Hzstf) Sound Internal residential muffler. Detachable central lifting point. Complete with engine and battery liquids. Oil draining facilities. Baseframe capable to be moved with hand pallet truck. Rental kit as option (POWER ON RENT). PRIME POWER PRP EMERGENCY POWER LTP Voltage Frequency Power factor Water 1.500 209 12,3 / 9,2 96 71 2.400x1.000x1.546 Perkins - 1104C-44TAG2 GSW110P 100,1 (80,1) 110,0 (88,0) 400 50 SU200TDA 0,8 71 2.400x1.000x1.546 1.260 Deutz - BF4M2012C Water 1.500 GSW80D SU740TDA 74,1 (59,3) 78,5 (62,8) 400 50 0,8 209 1.380 16,5 / 12,4 96 DIESEL ENGINE ZATIONS AND THE PRODUCER RESERVES THE RIGHT TO MODIFY THEM FOR INNOVATIONS WITHOUT PRIOR NOTICE Canopy made in zincted steel profiles with green power coated layer. Cos φ Speed rpm Hz Dimensions (LxWxH) mm Autonomy (75/100% load PRP) h Acoustic pressure at 7m Acoustic power LWA Litres dB(A) Brand Model CODE Cooling system kg Volt Three phase Type kVA (kW) kVA (kW) Weight Liquid cooling Diesel engine. Control panel protected by lockable door MODEL | GSW80 Deutz & 110 Perkins. Fuel capacity MODEL Fully bunded / Completly sealed baseframe as option. REF. PC5209_3St.00 GSW 80D GSW80D GSW110P 17,0 / 22,6 213 Electronic 12 UCI 274 C H IP21 1.500 4.410 4 L Turbo 89,0 / 98,0 12 UCI 224 F H 4 L Turbo 66,1 / 70,0 12,7 / 16,9 217 Mechanical 1.500 Displacement MANUAL CONTROL PANEL (MCP) ALTERNATOR c.c. Type Type (%) Insulation 4.040 TECHNICAL CHARACTERISTICS LISTED ARE NOT INCLUSIVE OF ANY PRODUCT CUSTOMIZ Cyliders and disposition l/h Engine governor Volt g/kWh Type Electrical system (DC) Specific consumption PRP MANUAL CONTROL PANEL (MCP) Commands and others Fuel consumption (75/100% load) Engine power PRP / LTP kWm Aspiration Speed rpm n° disp. • Start/stop selector switch with key (Glow plugs preheating function also included). • Emergency stop button installed on canopy side. • Engine protections: Battery charger failure, low fuel level, low oil pressure, high engine temperature. IP21 Instrumentation (analogue) Protections with alarm Protections with shutdown Type STAMFORD Voltage regulation Mechanical degree protection Class Ouput GSW 110P Manual control panel, mounted on the genset and complete of: analogue instrumentation, control, protection of the generating set and sockets, protected through door with lockable handle. • Power cables connected to Circuit Breaker Electronic (±1,5%) • Engine protections: Battery charger failure, low fuel level, low oil pressure, high engine temperature. • Circuit breaker protection: III poles. • Differential protection. • Genereting set voltage (1 phase). • Generating set current (1 phase). • Hours-counter. REF. PC5209_3St.00 Ouput lockable handle. • Power cables connected to Circuit Breaker REF. PC5209_3St.00 Rev.00 (Ago2010) Pag. 1 of 3

Upload: vudat

Post on 03-Jul-2019

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MODEL GSW80 Deutz & 110 Perkins. - PRATEC · • Engine temperature (depending on model) Ouput AUTOMATIC CONTROL PANEL (AMF) Protections with alarm • Engine protections: low fuel

Business Units GENERATORS Product Cards GSW65-80P(50Hzstf) Sound

Internal residential muffler.

Detachable central lifting point.

Complete with engine and battery liquids.

Oil draining facilities.

Baseframe capable to be moved with hand pallet truck.

Rental kit as option (POWER ON RENT).

PRIME POWER PRP

EMERGENCY POWER LTP

Voltage

Frequency

Power factor

Water

1.500

209

12,3 / 9,2

96

71

2.400x1.000x1.546

Perkins - 1104C-44TAG2

GSW110P

100,1 (80,1)

110,0 (88,0)

400

50

SU200TDA

0,8

71

2.400x1.000x1.546

1.260

Deutz - BF4M2012C

Water

1.500

GSW80D

SU740TDA

74,1 (59,3)

78,5 (62,8)

400

50

0,8

209

1.380

16,5 / 12,4

96

DIESEL ENGINE

TECHNICAL CHARACTERISTICS LISTED ARE N

OT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R N

OTICE

Canopy made in zincted steel profiles with green power coated layer.

Cos φ

Speed rpm

Hz

Dimensions (LxWxH) mm

Autonomy (75/100% load PRP) h

Acoustic pressure at 7m

Acoustic power LWA

Litres

dB(A)

Brand Model

CODE

Cooling system

kg

Volt

Thre

e p

hase

Type

kVA (kW)

kVA (kW)

Weight

Liquid cooling Diesel engine.

Control panel protected by lockable door

MODEL|GSW80 Deutz & 110 Perkins.

Fuel capacity

MODEL

Fully bunded / Completly sealed baseframe as option.

REF. PC5209_3St.00

GSW 80D

GSW80D GSW110P

17,0 / 22,6

213

Electronic

12

UCI 274 C

H

IP21

1.500

4.410

4 L

Turbo

89,0 / 98,0

12

UCI 224 F

H

4 L

Turbo

66,1 / 70,0

12,7 / 16,9

217

Mechanical

1.500

Displacement

MANUAL CONTROL PANEL (MCP)

ALTERNATOR

c.c.

Type

Type (%)

Insulation

4.040

TECHNICAL CHARACTERISTICS LISTED ARE N

OT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R N

OTICE

Cyliders and disposition

l/h

Engine governor

Volt

g/kWh

Type

Electrical system (DC)

Specific consumption PRP

MANUAL CONTROL PANEL (MCP) Commands and

others

Fuel consumption (75/100% load)

Engine power PRP / LTP kWm

Aspiration

Speed rpm

n° disp.

• Start/stop selector switch with key (Glow plugs preheating function also included).

• Emergency stop button installed on canopy side.

• Engine protections: Battery charger failure, low fuel level, low oil pressure, high engine temperature.

IP21

Instrumentation

(analogue)

Protections with

alarm

Protections with

shutdown

Type

STAMFORD

Voltage regulation

Mechanical degree protection

Class

Ouput

GSW 110P

Manual control panel, mounted

on the genset and complete of:

analogue instrumentation,

control, protection of the

generating set and sockets,

protected through door with

lockable handle.• Power cables connected to Circuit Breaker

Electronic (±1,5%)

• Engine protections: Battery charger failure, low fuel level, low oil pressure, high engine temperature.

• Circuit breaker protection: III poles.

• Differential protection.

• Genereting set voltage (1 phase).

• Generating set current (1 phase).

• Hours-counter.

REF. PC5209_3St.00

Ouputprotected through door with

lockable handle.• Power cables connected to Circuit Breaker

REF. PC5209_3St.00

Rev.00 (Ago2010) Pag. 1 of 3

Page 2: MODEL GSW80 Deutz & 110 Perkins. - PRATEC · • Engine temperature (depending on model) Ouput AUTOMATIC CONTROL PANEL (AMF) Protections with alarm • Engine protections: low fuel

Business Units GENERATORS Product Cards GSW65-80P(50Hzstf) Sound

GSW80D GSW110P

Protections with

shutdown

GSW80D GSW110P

• Four operation modes: OFF - Manual starting - Automatic starting - Automatic test.

• Plinth row for connection from ACP to LTS panel.

AUTOMATIC CONTROL PANEL (AMF)

GSW 80D

GSW 110 P

Automatic control panel

mounted on the genset,

complete with digital control

unit AC03 for monitoring,

control and protection of the

generating set, protected

through door with lockable

handle.

AUTOMATIC CONTROL PANEL (ACP)

Digital

instrumentation

through AC-03 control

unit.

Digital

instrumentation

through AC03 control

unit.

• Genereting set voltage (3 phases).

• Mains voltage.

• Generating set frequency.

• Generating set current (3 phases).

• Battery voltage.

• Power (kVA - kW - kVAr).

• Power factor Cos φ.

• Hours-counter.

• Engine speed r.p.m.

• Fuel level (%).

• Engine temperature (depending on model)

• Genereting set voltage (3 phases).

• Mains voltage.

• Generating set frequency.

• Generating set current (3 phases).

• Battery voltage.

• Power (kVA - kW - kVAr).

• Power factor Cos φ.

• Hours-counter.

• Engine speed r.p.m.

• Fuel level (%).

• Engine temperature (depending on model)

Ouput

AUTOMATIC CONTROL PANEL (AMF)

Protections with

alarm

• Engine protections: low fuel level, low oil pressure, high engine temperature.

• Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage

• Power cables connected to Circuit Breaker

AUTOMATIC CONTROL PANEL (ACP)TECHNICAL CHARACTERISTICS LISTED ARE NOT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R NOTICE

• Engine protections: low fuel level, low oil pressure, high engine temperature,

• Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure.

• Circuit breaker protection:III poles.

• Differential protection by means of the control unit.

Commands and

others

• Four operation modes: OFF - Manual starting - Automatic starting - Automatic test.

• Pushbutton for forcing Mains contactor or Genset contactor.

• Push-buttons: start/stop, fault reset, up/down/page/enter selection.

• Remote starting availability.

• DC system disconnection switch.

• Acoustic alarm.

• Automatic battery charger.

• RS232 Comuncation port.

• Setable PASSWORD for protection level.

• Emergency stop button installed on canopy side.

GENSET SUPPLEMENTS (ONLY AVAILABLE WHEN ORDERED)

Earth rod.

Battery switch.

DCC: DIFFERENT CANOPY COLOUR.

IV poles - 200 A.

• Four operation modes: OFF - Manual starting - Automatic starting - Automatic test.

• Pushbutton for forcing Mains contactor or Genset contactor.

• Push-buttons: start/stop, fault reset, up/down/page/enter selection.

• Emergency stop button.

• Remote starting inhibition availability.

• Acoustic alarm.

• Automatic battery charger.

• RS232 Comuncation port.

• Setable PASSWORD for protection level.

Sockets kit (5 sockets).

with individual CB and Earth Fault protection

Fuel filter water separator.

Three phase

Protections with

alarm

AUTOMATIC CONTROL PANEL (AMF)

Change over

contactors

Mains/Genset

Commands and

others

GENSET SUPPLEMENTS

KRT: RENTAL KIT.. Complete of:

EEG: ENGINE ELECTRONIC GOVERNOR.

External terminal board

Output

Protections with

shutdown

APM: PMG FOR STAMFORD ALTERNATOR + MX321 AVR.

IV poles - 110 A.

• Engine protections: low fuel level, low oil pressure, high engine temperature.

• Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage.

• Engine protections: low fuel level, low oil pressure, high engine temperature,

• Genset protection: under/over voltage, overload, under/over battery voltage.

• Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel.

• Power cables connected to terminals board (internal).

AFP: AUTOMATIC FUEL TRANSFER PUMP.

TECHNICAL CHARACTERISTICS LISTED ARE NOT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R NOTICE

Three way valve.

Manual set folder

PHS: COOLANT PREHEATING SYSTEM.

1 x 400V/63A 3P+N+T CE.

1 x 400V/32A 3P+N+T CE.

1 x 400V/16A 3P+N+T CE.

1 x 230V/16A 2P+T CE.

1 x 230V/16A Schuko.

Automatic control panel for

automatic starting by Mains

failure. Delivered loose from

the genset, and complete

with digital control unit

AC03 for monitoring,

control and protection of the

generating set.

KPR: KIT PREMIUM (Completly sealed baseframe + alarm per liquid level in baseframe +Manual oil drain pump)

PHS: COOLANT PREHEATING SYSTEM.

Rev.00 (Ago2010) Pag. 2 of 3

Page 3: MODEL GSW80 Deutz & 110 Perkins. - PRATEC · • Engine temperature (depending on model) Ouput AUTOMATIC CONTROL PANEL (AMF) Protections with alarm • Engine protections: low fuel

Business Units GENERATORS Product Cards GSW65-80P(50Hzstf) Sound

CONTROL PANEL SUPPLEMENTS (ONLY AVAILABLE WHEN ORDERED)

GSW110P

• Power cables connection to terminals board (internal).

MPF: MANUAL ANALOGUE CONTROL PANEL FULL OPTION.

Output

Protections with

alarm

Manual control panel

mounted on the genset, with

analogue instrumentation,

and protected through door

with lockable handle.

IV poles - 110 A. IV poles - 200 A.

GSW80D

• Voltmeter with selector switch (3 phases).

• Frequency meter.

• Ammeter with selector switch (3 phases).

• Hours-counter.

• Fuel level indicator.

• Start/stop selector switch with key (single key system)

• Emergency stop button.

• Engine protections: low fuel level, low oil pressure, high engine temperature, battery charger failure.

TIF: IV POLES CIRCUIT BREAKER INSTEAD OF III POLES.

Commands and

others

Instrumentation

(analogue)

Change over

contactors

Connections

LOAD TRANSFER SWITCH PANEL.

• Plinth row for connection from ACP to LTS panel.

• Terminals board for power cables connection (Genset-Mains-Load).

Three phase

CONTROL PANEL SUPPLEMENTS

TECHNICAL CHARACTERISTICS LISTED ARE NOT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R NOTICE

ACCESSORIES

Protections with

shutdown

ETB: EXTERNAL TERMINAL BOARD. Heavy duty cupper bars of easy external power cables connection.

• Engine protection unit: low fuel level, low pressure oil, high engine temperature, battery charger failure.

• Circuit breaker protection: III poles.

• Differential protection.

RSS: REMOTE START/STOP. Only for MCP

Sockets kit (5 sockets).

with individual CB and Earth Fault protection

1 x 400V/63A 3P+N+T CE.

1 x 400V/32A 3P+N+T CE.

1 x 400V/16A 3P+N+T CE.

1 x 230V/16A 2P+T CE.

1 x 230V/16A Schuko.

RTR: ROAD TRAILER (only for Spanish terrritories). Single axle.

ACCESSORIES

Protections

GSB: GALVANIZED SKIDS. Heavy duty galvanized skid to be installed under the genset.

Easily transportable with fork lift.

Load transfer switch panel

built in a metal cabinet and

supplied loose from the

genset.

RCG: REMOTE CONTROL BY GSM KIT (kit for genset management and control by remote PC; comunication

available by means of RS232 directly to PC or through GSM modem). Others remote monitoring system under request.

These kits are only available on the automatic versions.

STR: SITE TRAILER. Single axle.

• Contactors mechanically and electrically interlocked.

• Emergency stop button.

Note: Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains failure. It transfers

immediately the load again to the genset when the Mains voltage returns within the rated values.

TECHNICAL CHARACTERISTICS LISTED ARE NOT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R NOTICE

Rev.00 (Ago2010) Pag. 3 of 3

Page 4: MODEL GSW80 Deutz & 110 Perkins. - PRATEC · • Engine temperature (depending on model) Ouput AUTOMATIC CONTROL PANEL (AMF) Protections with alarm • Engine protections: low fuel

Business Units GENERATORS Product Cards GSW80D-110P (50Hzstf) Sound

Internal residential muffler.

Detachable central lifting point.

Complete with engine and battery liquids.

Oil draining facilities.

Baseframe capable to be moved with hand pallet truck.

Rental kit as option (POWER ON RENT).

PRIME POWER PRP

EMERGENCY POWER LTP

Voltage

Frequency

Power factor

Water

1.500

12,3 / 9,2

96

71

2.400x1.000x1.546

1.499

Perkins - 1104C-44TAG2

GSW110P

SU200TDA

102,6 (82,1)

112,9 (90,4)

400

50

0,8

209

0,8

209

16,5 / 12,4

96

1.500

GSW80D

SU740TDA

74,3 (59,4)

77,7 (62,2)

400

50

71

2.400x1.000x1.546

1.221

Deutz - BF4M2012C

Water

Fully bunded / Completly sealed baseframe as option.

Liquid cooling Diesel engine.

Control panel protected by lockable door

MODEL|GSW80Deutz & 110Perkins

Fuel capacity

MODEL

CODE

Volt

Thre

e p

hase kVA (kW)

kVA (kW)

Cos φ

Litres

Cooling system

kg

Autonomy (75/100% load PRP) h

Acoustic pressure at 7m

Acoustic power

Type

Weight

Canopy made in zincted steel profiles with green power coated layer.

rpm

LWA

dB(A)

DIESEL ENGINEBrand

Model

Hz

Dimensions (LxWxH) mm

Speed

TECHNICAL CHARACTERISTICS LISTED ARE N

OT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R N

OTICE

REF. PC5209_3Me.00

IP21

GSW80D GSW110P

Type

17,0 / 22,6

213

Electronic

12

ECP 34 2S

H

1.500

4.410

4 L

Turbo

89,0 / 98,0

H

IP21

4.040

4 L

Turbo

Mechanical

12

66,1 / 70,0

12,7 / 16,9

217

1.500

Electronic (±1,5%)

• Engine protections: Battery charger failure, low fuel level, low oil pressure, high engine temperature.

• Circuit breaker protection: III poles.

• Differential protection.

• Start/stop selector switch with key (Glow plugs preheating function also included).

• Emergency stop button installed on canopy side.

• Engine protections: Battery charger failure, low fuel level, low oil pressure, high engine temperature.

MeccAlte

MANUAL CONTROL PANEL (MCP)

Protections with

alarm

Insulation

GSW 80 D

GSW 110 P

Manual control panel,

mounted on the genset and

complete of: analogue

instrumentation, control,

protection of the generating

set and sockets, protected

through door with lockable

• Genereting set voltage (1 phase).

• Generating set current (1 phase).

• Hours-counter.

ECO 32 3L

Engine governor

Class

g/kWh

Electrical system (DC)

rpm

kWm

Aspiration

Displacement

Instrumentation

(analogue)

Specific consumption PRP

n° disp.

Commands and

others

Protections with

shutdown

Voltage regulation

c.c.

Type

Type (%)

Volt

Type

Cyliders and disposition

l/hFuel consumption (75/100% load)

Engine power PRP / LTP

Speed

TECHNICAL CHARACTERISTICS LISTED ARE N

OT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R N

OTICE

MANUAL CONTROL PANEL (MCP)

ALTERNATOR

Mechanical degree protection

REF. PC5209_3Me.00

Ouputthrough door with lockable

handle. • Power cables connected to Circuit Breaker

REF. PC5209_3Me.00

Rev.00 (Ago2010) Pag. 1 of 3

Page 5: MODEL GSW80 Deutz & 110 Perkins. - PRATEC · • Engine temperature (depending on model) Ouput AUTOMATIC CONTROL PANEL (AMF) Protections with alarm • Engine protections: low fuel

Business Units GENERATORS Product Cards GSW80D-110P (50Hzstf) Sound

• Engine protections: low fuel level, low oil pressure, high engine temperature,

• Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure.

• Circuit breaker protection:III poles.

• Differential protection by means of the control unit.

GSW80D GSW110P

GSW80D GSW110P

• Engine protections: low fuel level, low oil pressure, high engine temperature.

• Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage

• Plinth row for connection from ACP to LTS panel.

GSW 110P

Automatic control panel

mounted on the genset,

complete with digital control

unit AC03 for monitoring,

control and protection of the

generating set, protected

through door with lockable

handle.

Protections with

alarm

• Power cables connected to Circuit Breaker

TECHNICAL CHARACTERISTICS LISTED ARE NOT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R NOTICE

AUTOMATIC CONTROL PANEL (ACP)

GSW 80D

• Genereting set voltage (3 phases).

• Mains voltage.

• Generating set frequency.

• Generating set current (3 phases).

• Battery voltage.

• Power (kVA - kW - kVAr).

• Power factor Cos φ.

• Hours-counter.

• Engine speed r.p.m.

• Fuel level (%).

• Engine temperature (depending on model).

Digital

instrumentation

through AC03 control

unit.

• Genereting set voltage (3 phases).

• Mains voltage.

• Generating set frequency.

• Generating set current (3 phases).

• Battery voltage.

• Power (kVA - kW - kVAr).

• Power factor Cos φ.

• Hours-counter.

• Engine speed r.p.m.

• Fuel level (%).

• Engine temperature (depending on model).

Commands and

others

AUTOMATIC CONTROL PANEL (ACP)

Digital

instrumentation

through AC-03 control

unit.

Protections with

shutdown

Ouput

AUTOMATIC CONTROL PANEL (AMF)

AUTOMATIC CONTROL PANEL (AMF)

• Four operation modes: OFF - Manual starting - Automatic starting - Automatic test.

• Pushbutton for forcing Mains contactor or Genset contactor.

• Push-buttons: start/stop, fault reset, up/down/page/enter selection.

• Remote starting availability.

• DC system disconnection switch.

• Acoustic alarm.

• Automatic battery charger.

• RS232 Comuncation port.

• Setable PASSWORD for protection level.

• Emergency stop button installed on canopy side.

• Four operation modes: OFF - Manual starting - Automatic starting - Automatic test.

GENSET SUPPLEMENTS (ONLY AVAILABLE WHEN ORDERED)

IV poles - 110 A. IV poles - 200 A.

PHS: COOLANT PREHEATING SYSTEM.

KRT: RENTAL KIT.. Complete of:

• Engine protections: low fuel level, low oil pressure, high engine temperature.

• Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage.

• Engine protections: low fuel level, low oil pressure, high engine temperature,

• Genset protection: under/over voltage, overload, under/over battery voltage.

• Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel.

• Power cables connected to terminals board (internal).

AFP: AUTOMATIC FUEL TRANSFER PUMP.

Change over

contactors

Mains/Genset

TECHNICAL CHARACTERISTICS LISTED ARE NOT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R NOTICE

Manual set folder

GENSET SUPPLEMENTS

KPR: KIT PREMIUM (Completly sealed baseframe + alarm per liquid level in baseframe +Manual oil drain pump)

External terminal board

Output

Protections with

shutdown

DCC: DIFFERENT CANOPY COLOUR.

EEG: ENGINE ELECTRONIC GOVERNOR. (only available on Deutz EMR type)

Three way valve.

Commands and

others

AUTOMATIC CONTROL PANEL (AMF)

Protections with

alarm

Earth rod.

Battery switch.

Automatic control panel for

automatic starting by Mains

failure. Delivered loose from

the genset, and complete

with digital control unit

AC03 for monitoring,

control and protection of the

generating set.

1 x 230V/16A 2P+T CE.

1 x 230V/16A Schuko.

• Four operation modes: OFF - Manual starting - Automatic starting - Automatic test.

• Pushbutton for forcing Mains contactor or Genset contactor.

• Push-buttons: start/stop, fault reset, up/down/page/enter selection.

• Emergency stop button.

• Remote starting inhibition availability.

• Acoustic alarm.

• Automatic battery charger.

• RS232 Comuncation port.

• Setable PASSWORD for protection level.

Fuel filter water separator.

Three phase

Sockets kit (5 sockets).

with individual CB and Earth Fault protection

1 x 400V/63A 3P+N+T CE.

1 x 400V/32A 3P+N+T CE.

1 x 400V/16A 3P+N+T CE.

KPR: KIT PREMIUM (Completly sealed baseframe + alarm per liquid level in baseframe +Manual oil drain pump)

Rev.00 (Ago2010) Pag. 2 of 3

Page 6: MODEL GSW80 Deutz & 110 Perkins. - PRATEC · • Engine temperature (depending on model) Ouput AUTOMATIC CONTROL PANEL (AMF) Protections with alarm • Engine protections: low fuel

Business Units GENERATORS Product Cards GSW80D-110P (50Hzstf) Sound

CONTROL PANEL SUPPLEMENTS (ONLY AVAILABLE WHEN ORDERED)

GSW80D GSW110P

IV poles - 110 A. IV poles - 200 A.

• Contactors mechanically and electrically interlocked.

• Emergency stop button.

ACCESSORIES

Three phase

TECHNICAL CHARACTERISTICS LISTED ARE NOT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R NOTICE

ETB: EXTERNAL TERMINAL BOARD. Heavy duty cupper bars of easy external power cables connection.

Protections

Change over

contactors

Connections

Load transfer switch panel

LOAD TRANSFER SWITCH PANEL.

• Plinth row for connection from ACP to LTS panel.

• Terminals board for power cables connection (Genset-Mains-Load).

Commands and

others

• Engine protection unit: low fuel level, low pressure oil, high engine temperature, battery charger failure.

• Circuit breaker protection: III poles.

• Differential protection.

• Voltmeter with selector switch (3 phases).

• Frequency meter.

• Ammeter with selector switch (3 phases).

• Hours-counter.

• Fuel level indicator.

• Oil pressure indicator.

• Engine temperature indicator.

Protections with

shutdown

• Start/stop selector switch with key (single key system)

• Emergency stop button.

• Engine protections: low fuel level, low oil pressure, high engine temperature, battery charger failure.

TIF: IV POLES CIRCUIT BREAKER INSTEAD OF III POLES.

RSS: REMOTE START/STOP. Only for MCP

Instrumentation

(analogue)

MPF: MANUAL ANALOGUE CONTROL PANEL FULL OPTION.

Sockets kit (5 sockets).

with individual CB and Earth Fault protection

1 x 400V/63A 3P+N+T CE.

Output

Protections with

alarm

Manual control panel

mounted on the genset, with

analogue instrumentation,

and protected through door

with lockable handle.

CONTROL PANEL SUPPLEMENTS

• Power cables connection to terminals board (internal).

1 x 400V/32A 3P+N+T CE.

1 x 400V/16A 3P+N+T CE.

1 x 230V/16A 2P+T CE.

1 x 230V/16A Schuko.

• Emergency stop button.

TECHNICAL CHARACTERISTICS LISTED ARE NOT INCLUSIVE O

F ANY PRODUCT CUSTOMIZATIO

NS AND THE PRODUCER RESERVES THE RIG

HT TO M

ODIFY THEM FOR INNOVATIO

NS W

ITHOUT PRIO

R NOTICE

Note: Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains failure. It transfers

immediately the load again to the genset when the Mains voltage returns within the rated values.

RCG: REMOTE CONTROL BY GSM KIT (kit for genset management and control by remote PC; comunication

available by means of RS232 directly to PC or through GSM modem). Others remote monitoring system under request.

These kits are only available on the automatic versions.

STR: SITE TRAILER. Single axle.

RTR: ROAD TRAILER (only for Spanish terrritories). Single axle.

ACCESSORIES

GSB: GALVANIZED SKIDS. Heavy duty galvanized skid to be installed under the genset.

Easily transportable with fork lift.

Load transfer switch panel

built in a metal cabinet and

supplied loose from the

genset.

Rev.00 (Ago2010) Pag. 3 of 3