GENERATING SET TECHNICAL GUIDE GSW95V-275V Open set MODEL TECHNICAL FEATURES PRIME POWER PRP kVA (kW) Manual / Automatic control panel mounted on the genset, protected by a locking door, complete with digital control Output kWm Electronic IP23 Electronic IP23 ALTERNATOR STAMFORD Engine governor (standard) Protections with alarm Protections with shutdown • Engine protections: low fuel level, low oil pressure, high engine temperature. • Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage, battery charger failure. • Circuit breaker protection: III poles. • Differential protection. • Engine protections: low fuel level, low oil pressure, high engine temperature, low coolant level. • Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. • Plinth row for connection from ACP to LTS panel. • Power cables connection to terminals board (external). IP23 Insulation Class Mechanical degree of protection Type Voltage regulation Type Displacement c.c. Cylinders and disposition n° disp. Type Aspiration Fuel consumption (100% load) Type L/h Fuel consumption (75% load) L/h Engine power PRP Weight (dry) Cooling system Type Speed r.p.m DIESEL ENGINE Fuel capacity Litres Dimensions (LxWxH) mm Autonomy (100% load PRP) h 50 VOLVO 240 13.3 2200 x 1000 x 1700 1200 kg Cos φ 50 0.8 0.8 EMERGENCY POWER LTP kVA (kW) 400/231 400/231 Voltage Volt Power factor Frequency 50 STAMFORD alternator. MODEL | GSW95-275 Volvo VOLVO Diesel engine. Water cooling system with radiator. Industrial muffler. Complete with engine and battery liquids. 400/231 400/231 400/231 400/231 MANUAL / AUTOMATIC CONTROL PANEL (ACP) Digital instrumentation Commands and others • Genereting set voltage (3 phases). • Mains voltage. • Generating set frequency. • Generating set current (3 phases). • Battery voltage. • Power (kVA - kW - kVAr). • Power factor Cos φ. • Hours-counter. • Engine speed r.p.m. • Fuel level (%). • Oil pressure. • Engine temperature. Electronic • Selector switch with six positions: Automatic test - Automatic starting - Engine locked - Mains contactor forced - Manual starting - Genset contactor forced. • Push-buttons: start/stop, up/down selection, reset. • Emergency stop button. • DC system disconnection key. • Acoustic alarm. • Automatic battery charger. GSW95V 83 (66) 91 (73) TAD530GE Water 1500 Hz 4760 4 L Turbo - Intercooler 74 18 16 Mechanical UCI224G H GSW110V 97 (78) 108 (86) 240 11.4 2200 x 1000 x 1700 1250 TAD531GE Water 1500 4760 4 L Turbo - Intercooler 86 21 19 Mechanical UCI274D H GSW145V 127 (102) 142 (114) 0.8 240 8.8 2200 x 1000 x 1700 1370 TAD532GE Water 1500 4760 4 L Turbo - Intercooler 114 27 25 Electronic UCI274E H IP23 Electronic GSW170V 153 (122) 170 (136) 400/231 50 0.8 240 7.5 2600 x 1000 x 1700 1820 TAD731GE Water 1500 7150 6 L Turbo - Intercooler 133 32 29 Mechanical UCI274F H GSW195V 182 (146) 200 (160) 50 0.8 400 10.2 2650 x 1200 x 1800 1980 TAD732GE Turbo - Intercooler 160 39 34 2650 x 1200 x 1800 Electronic UCI274G H Water 1500 7150 6 L 2200 TAD733GE 7150 6 L GSW220V 203 (162) 220(176) 50 0.8 400 9.3 2650 x 1200 x 1844 Electronic UCI274H H Turbo - Intercooler 177 43 38 Water 1500 50 0.8 400 8.16 GSW275V 249 (199) 275 (220) 2326 TAD734GE Water 1500 7150 6 L Turbo - Intercooler 213 49 39 Electronic UCD274K H IP23 Electronic Electronic Electronic IP23 IP23

Upload: trinhthien

Post on 15-Jul-2018

212 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MODEL GSW95-275 Volvo - واردات دیزل ژنراتور · through AC-01 control unit (CAN BUS). • Plinth row for connection from pre-wired panel (mounted on the genset) to

GENERATING SET TECHNICAL GUIDE GSW95V-275V Open set

MODELCODE

TECH

NIC

AL F

EATU

RES

PRIME POWER PRP kVA (kW)

Manual / Automatic control panel mounted on the genset, protected by a locking door, complete with digital control unit AC3000 for monitoring,

control and protection of the generating set.

Output

kWm

ElectronicIP23

ElectronicIP23

ALTERNATOR STAMFORDEngine governor (standard)

Protections with alarm

Protections with shutdown

• Engine protections: low fuel level, low oil pressure, high engine temperature. • Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage, battery charger failure. • Circuit breaker protection: III poles. • Differential protection.

• Engine protections: low fuel level, low oil pressure, high engine temperature, low coolant level.• Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure.

• Plinth row for connection from ACP to LTS panel.• Power cables connection to terminals board (external).

IP23Insulation ClassMechanical degree of protection TypeVoltage regulation Type

MANUAL / AUTOMATIC CONTROL PANEL (ACP)

Displacement c.c.Cylinders and disposition n° disp.

TypeAspiration

Fuel consumption (100% load)

Type

L/hFuel consumption (75% load) L/h

Engine power PRP

Weight (dry)

Cooling system TypeSpeed r.p.m

DIESEL ENGINE

Fuel capacity Litres

Dimensions (LxWxH) mmAutonomy (100% load PRP) h

50

VOLVO

24013.3

2200 x 1000 x 1700

1200kg

Cos φ500.8 0.8

EMERGENCY POWER LTP kVA (kW)400/231 400/231Voltage Volt

Power factorFrequency 50

STAMFORD alternator.

MODEL|GSW95-275 Volvo

VOLVO Diesel engine.

Water cooling system with radiator.

Industrial muffler.

Complete with engine and battery liquids.

TECH

NIC

AL C

HAR

ACTE

RIST

ICS

NO

T IM

PEG

NAT

IVE

RESE

RVAT

ION

OF

MO

DIF

ICAT

ION

S FO

R IN

NO

VATI

ON

OF

THE

PR

OD

UCT

GSW450V GSW510V GSW560V GSW590V

400/231 400/231 400/231 400/231

MAN

UAL

/ A

UTO

MAT

IC C

ON

TRO

L PA

NEL

(AC

P)

Digital instrumentation

through AC3000control unit(CAN BUS).

Commands and others

GSW415VGSW310V GSW330V• Genereting set voltage (3 phases). • Mains voltage.• Generating set frequency. • Generating set current (3 phases). • Battery voltage.• Power (kVA - kW - kVAr).• Power factor Cos φ. • Hours-counter.• Engine speed r.p.m.• Fuel level (%).• Oil pressure. • Engine temperature.

Electronic

• Selector switch with six positions: Automatic test - Automatic starting - Engine locked - Mains contactor forced - Manual starting - Genset contactor forced. • Push-buttons: start/stop, up/down selection, reset.• Emergency stop button. • DC system disconnection key. • Acoustic alarm. • Automatic battery charger.

GSW95V SG281TWA

83 (66) 91 (73)

TAD530GEWater 1500

Hz

47604 L

Turbo - Intercooler

741816

Mechanical UCI224G

H

GSW110VSG331TWA

97 (78) 108 (86)

24011.4

2200 x 1000 x 1700

1250TAD531GE

Water 150047604 L

Turbo - Intercooler

86 2119

Mechanical UCI274D

H

GSW145VSG371TWA

127 (102)142 (114)

0.82408.8

2200 x 1000 x 1700

1370TAD532GE

Water 15004760

4 LTurbo - Intercooler

1142725

Electronic UCI274E

HIP23

Electronic

GSW170VSG401TWA

153 (122)170 (136)400/231

500.8240 7.5

2600 x 1000 x 1700

1820TAD731GE

Water 15007150

6 LTurbo - Intercooler

133 3229

Mechanical UCI274F

H

GSW195VSG451TWA

182 (146)200 (160)

500.840010.2

2650 x 1200 x 1800

1980TAD732GE

Turbo - Intercooler

160 3934

2650 x 1200 x 1800

Electronic UCI274G

H

Water 15007150

6 L

2200TAD733GE

71506 L

GSW220VSG501TWA

203 (162) 220(176)

500.84009.3

2650 x 1200 x 1844

Electronic UCI274H

H

Turbo - Intercooler

177 4338

Water 1500

500.84008.16

GSW275VSG571TWA

249 (199)275 (220)

2326TAD734GE

Water 1500 7150

6 LTurbo - Intercooler

213 49 39

Electronic UCD274K

HIP23

ElectronicElectronic ElectronicIP23IP23

REF. GDS 11.01

Rev.00 Pag. 1 of 2

Page 2: MODEL GSW95-275 Volvo - واردات دیزل ژنراتور · through AC-01 control unit (CAN BUS). • Plinth row for connection from pre-wired panel (mounted on the genset) to

GENERATING SET TECHNICAL GUIDE GSW310V-590V Open set

GENSET SUPPLEMENTS (ONLY AVAILABLE WHEN ORDERED)

CONTROL PANEL SUPPLEMENTS (ONLY AVAILABLE WHEN ORDERED)

CO

NTR

OL

PAN

EL S

UPP

LEM

ENTS

AFP: AUTOMATIC FUEL TRANSFER PUMP.

GEN

SET

SUPP

LEM

ENTS

RSS: REMOTE START & STOP PRE-ARRANGED FREE CONTACTS.

TECH

NIC

AL C

HAR

ACTE

RIS

TICS

NO

T IM

PEG

NAT

IVE

RES

ERVA

TIO

N O

F M

OD

IFIC

ATIO

NS

FOR

IN

NO

VATI

ON

OF

THE

PR

OD

UCT

Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and complete

with digital control unit AC01 for monitoring, control and protection of the generating

set.

• Genereting set voltage (3 phases). • Mains voltage.• Generating set frequency. • Generating set current (3 phases). • Battery voltage.• Power (kVA - kW - kVAr).• Power factor Cos φ. • Hours-counter.• Engine speed r.p.m.• Fuel level (%).• Oil pressure. • Engine temperature.

GSW330V GSW415V GSW450VGSW310V

AUTO

MAT

IC C

ON

TRO

L PA

NEL

(AM

F)

Commands and others

Digital instrumentation

through AC-01 control unit (CAN BUS).

• Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel.• Power cables connected to terminals board (internal).

• Plinth row for connection from ACP to LTS panel. • Terminals board for power cables connection (Genset-Mains-Load).

PHS: COOLANT PREHEATING SYSTEM.

• Engine protections: low fuel level, low oil pressure, high engine temperature. • Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage, battery charger failure.

• Engine protections: low fuel level, low oil pressure, high engine temperature, low coolant level.• Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure.

GSW560V

Protections with shutdown

Output

GSW590V

IV poles - 500A

LOAD TRANSFER SWITCH PANEL.

RES: RESIDENTIAL SILENCER.

FEC: FLEXIBLE EXHAUST COMPENSATOR.

Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values.

Change over contactors

GSW450V GSW510V

IV poles - 1.000A

ACCE

SSO

RIE

S

Connections

Protections

RCG: REMOTE CONTROL BY GSM KIT (kit for genset management and control by remote PC; comunication available by means of RS232 directly to PC or through GSM modem). Available only for automatic versions with AC01 control unit.

GSW415V

Load transfer switch panel built in a metal cabinet and

supplied loose from the genset.

• Contactors mechanically and electrically interlocked. • Emergency stop button.

Change over contactors

Mains/Genset

GSW310V GSW330V

• Selector switch with six positions: Automatic test - Automatic starting - Engine locked - Mains contactor forced - Manual starting - Genset contactor forced. • Push-buttons: start/stop, up/down selection, reset.• Emergency stop button. • Remote starting availability. • Acoustic alarm. • Automatic battery charger.

AUTOMATIC CONTROL PANEL (AMF)

TIF: IV POLES CIRCUIT BREAKER INSTEAD OF III POLES.

ACCESSORIES

GSW510V GSW560V GSW590V

IV poles - 700A

IV poles - 1.000A

IV poles - 1.000A

GPA: ALTERNATOR IP23 PROTECTION.

IV poles - 500A

IV poles - 500A

IV poles - 700A

IV poles - 700A

Protections with alarm

IV poles - 1.000A

IV poles - 500A

IV poles - 700A

IV poles - 700A

IV poles - 700A

Rev.00 Pag. 2 of 2