PLYMOUTH NORTH HIGH SCHOOL WIND TURBINE PROJECT
Model High School Site 41 Obery Street
Plymouth, MA
![Page 2: Model High School Site 41 Obery Street Plymouth, MA](https://reader036.vdocument.in/reader036/viewer/2022062321/56649e715503460f94b701b7/html5/thumbnails/2.jpg)
Atlantic Design Engineers, LLC (Atlantic) conducted an initial wind turbine siting and feasibility analysis of the PNHS property.
Atlantic completed a series of studies to obtain a better understanding of the impacts associated with a turbine in this location including:
Shadow Flicker Impact Study Photosimulations from various locations around the site Zone of Visual Influence (ZVI) Map
Atlantic then completed a noise monitoring program and Acoustic Analysis to determine the background (ambient) noise levels at various locations surrounding the site; and selected a representative turbine (900kW EWT) to acquire a better understanding of the specific acoustic impacts the project may have on nearby residential neighborhoods.
Project History
![Page 3: Model High School Site 41 Obery Street Plymouth, MA](https://reader036.vdocument.in/reader036/viewer/2022062321/56649e715503460f94b701b7/html5/thumbnails/3.jpg)
Conceptual Site Plan – 900 kW Turbine
![Page 4: Model High School Site 41 Obery Street Plymouth, MA](https://reader036.vdocument.in/reader036/viewer/2022062321/56649e715503460f94b701b7/html5/thumbnails/4.jpg)
Conceptual Site Plan – 750 kW Turbine
![Page 5: Model High School Site 41 Obery Street Plymouth, MA](https://reader036.vdocument.in/reader036/viewer/2022062321/56649e715503460f94b701b7/html5/thumbnails/5.jpg)
Conceptual Site Plan – 225 kW Turbine
![Page 6: Model High School Site 41 Obery Street Plymouth, MA](https://reader036.vdocument.in/reader036/viewer/2022062321/56649e715503460f94b701b7/html5/thumbnails/6.jpg)
![Page 7: Model High School Site 41 Obery Street Plymouth, MA](https://reader036.vdocument.in/reader036/viewer/2022062321/56649e715503460f94b701b7/html5/thumbnails/7.jpg)
![Page 8: Model High School Site 41 Obery Street Plymouth, MA](https://reader036.vdocument.in/reader036/viewer/2022062321/56649e715503460f94b701b7/html5/thumbnails/8.jpg)
![Page 9: Model High School Site 41 Obery Street Plymouth, MA](https://reader036.vdocument.in/reader036/viewer/2022062321/56649e715503460f94b701b7/html5/thumbnails/9.jpg)
![Page 10: Model High School Site 41 Obery Street Plymouth, MA](https://reader036.vdocument.in/reader036/viewer/2022062321/56649e715503460f94b701b7/html5/thumbnails/10.jpg)
![Page 11: Model High School Site 41 Obery Street Plymouth, MA](https://reader036.vdocument.in/reader036/viewer/2022062321/56649e715503460f94b701b7/html5/thumbnails/11.jpg)
![Page 12: Model High School Site 41 Obery Street Plymouth, MA](https://reader036.vdocument.in/reader036/viewer/2022062321/56649e715503460f94b701b7/html5/thumbnails/12.jpg)
Energy production numbers are based on the following: Predicted Wind Resource:
5.4 m/s at 40 m (131’) AGL 5.7 m/s at 55 m (180’) AGL 6.4 m/s at 75 m (246’) AGL
Annual energy production loss factor of 8%
75 m EWT 54-900: 900 kW Rated Capacity: 2,124,000 kWh/year*
71 m Gamesa G58: 850 kW Rated Capacity: 2,117,000 kWh/year
55 m Aeronautica 54-750: 750 kW Rated Capacity: 1,604,000 kWh/year
40 m Aeronautica 29-225: 225 kW Rated Capacity: 313,000 kWh/year
*: Model used to complete Shadow Flicker, Visual, and Noise Impact Assessments
Energy Production Estimates