model la-60b model la-80b la-28b la-45b la-60b la-80b · la-100 la-120 r jqa-2160 linear products...

2
Nitto Kohki’s Large Type Extra Large Type Medium Type Compact Type LA-28B & LA-45B LA-60B & LA-80B LA-100 & LA-120 LAM-200 Benefits include: Low Noise Low Power Consumption Easy Maintenance Unrivaled Lifetime Weatherproof Case IP55 Model For aerobic sewage treatment system and aquatics Cat.NO.Lk048 Model Power Supply Rated Frequency Rated Pressure Operating Pressure Range Rated Airflow Weight 120 V, 220 V, 230 V, 240 V AC 50 Hz, 60 Hz Specifications Power Consumption Low Power Consumption Highly efficient blower saves energy. Quiet Technology High performance sound proofing gives quiet operation. Easy Maintenance Only one screwdriver is needed for filter replacement. Oilless Design Offering Both Dry and Clean Air Low Running Temperature Energy saving design greatly reduces heating effect. Long Service Life with Linear Piston Technology The rated specifications enable continuous operation for over 20,000 hours. Light, Compact Compact and ready-to-use design. Easy Installation No earthing/grounding work is required. Features 0.11 bar (1.56 psig) 0.05 - 0.2 bar (0.71 - 2.84 psig) 28 LPM 29 W / 50 Hz 25.5 W / 60 Hz 2.8 kg LA-28B LA-45B LA-60B LA-80B LA-100 LA-120 LAM-200 45 LPM 47 W / 50 Hz 45 W / 60 Hz 3.0 kg 60 LPM 64 W / 50 Hz 60 W / 60 Hz 5.0 kg 80 LPM 86 W / 50 Hz 80 W / 60 Hz 5.3 kg 100 LPM 100 W / 50 Hz 95 W / 60 Hz 9.4 kg 120 LPM 130 W / 50 Hz 118 W / 60 Hz 9.4 kg 200 LPM 215 W / 50 Hz 12.3 kg 0.05 - 0.25 bar (0.71- 3.56 psig) 0.05 - 0.3 bar (0.71- 4.27 psig) 0.15 bar (2.13 psig) 0.18 bar (2.56 psig) 0.20 bar (2.84 psig) Model LA-28B LA-45B Model LA-60B LA-80B Model LAM-200 Model LA-100 LA-120 Model LA-28B LA-45B Model LA-60B LA-80B Model LAM-200 Model LA-100 LA-120 R JQA-2160 Linear Products Division JQA-EM4057 Headquarters Research Center ISO 9001 ISO 14001 NEW

Upload: others

Post on 07-Oct-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Model LA-60B Model LA-80B LA-28B LA-45B LA-60B LA-80B · LA-100 LA-120 R JQA-2160 Linear Products Division JQA-EM4057 Headquarters ISO 9001 Research Center ISO 14001 NEW ... 100 70

Nitto Kohki’s

Large Type

Extra Large Type

Medium Type

Compact Type

LA-28B & LA-45B

LA-60B & LA-80B

LA-100 & LA-120

LAM-200Benefits include: Low Noise Low Power Consumption Easy Maintenance Unrivaled Lifetime Weatherproof Case IP55

Model

For aerobic sewage treatment system and aquatics

Cat.NO.Lk048

ModelPower Supply Rated FrequencyRated Pressure Operating Pressure RangeRated Airflow

Weight

120 V, 220 V, 230 V, 240 V AC 50 Hz, 60 Hz

Specifications

Power Consumption

Low Power ConsumptionHighly efficient blower saves energy.Quiet TechnologyHigh performance sound proofing gives quiet operation.Easy MaintenanceOnly one screwdriver is needed for filter replacement.Oilless Design Offering Both Dry and Clean AirLow Running TemperatureEnergy saving design greatly reduces heating effect.

Long Service Life with Linear Piston TechnologyThe rated specifications enable continuous operation for over 20,000 hours.Light, CompactCompact and ready-to-use design.Easy InstallationNo earthing/grounding work is required.

Features

0.11 bar (1.56 psig) 0.05- 0.2 bar (0.71- 2.84 psig)

28 LPM29 W / 50 Hz

25.5 W / 60 Hz2.8 kg

LA-28B LA-45B LA-60B LA-80B LA-100 LA-120 LAM-200

45 LPM47 W / 50 Hz45 W / 60 Hz

3.0 kg

60 LPM64 W / 50 Hz60 W / 60 Hz

5.0 kg

80 LPM86 W / 50 Hz80 W / 60 Hz

5.3 kg

100 LPM100 W / 50 Hz95 W / 60 Hz

9.4 kg

120 LPM130 W / 50 Hz118 W / 60 Hz

9.4 kg

200 LPM

215 W / 50 Hz

12.3 kg

0.05- 0.25 bar (0.71-3.56 psig) 0.05- 0.3 bar (0.71-4.27 psig) 0.15 bar (2.13 psig) 0.18 bar (2.56 psig) 0.20 bar (2.84 psig)

ModelLA-28B LA-45B

ModelLA-60B LA-80B

ModelLAM-200

ModelLA-100 LA-120

ModelLA-28B LA-45B

ModelLA-60B LA-80B

ModelLAM-200

ModelLA-100 LA-120

R JQA-2160Linear Products DivisionJQA-EM4057HeadquartersResearch Center

ISO 9001ISO 14001

NEW

Page 2: Model LA-60B Model LA-80B LA-28B LA-45B LA-60B LA-80B · LA-100 LA-120 R JQA-2160 Linear Products Division JQA-EM4057 Headquarters ISO 9001 Research Center ISO 14001 NEW ... 100 70

Ø18

207173

44

182

205

Rated Pressure : 0.18 bar (2.56 psig)(0.018 MPa)LA-1001301201101009080706050

Rated Pressure : 0.18 bar (2.56 psig)(0.018 MPa)LA-120

150

140

130

120

110

100

90

80

70

Rated Pressure : 0.11 bar (1.56 psig)(0.011 MPa) Rated Pressure : 0.11 bar (1.56 psig)(0.011 MPa)

50

40

30

20

100.010.11.42

0.010.11.42

0.0150.152.13

0.0150.152.13

0.020.22.84

0.020.22.84

50Hz60Hz

LA-28B60

50

40

30

20

[MPa][bar] [psig]

[MPa][bar] [psig]

[MPa][bar] [psig]

[MPa][bar] [psig]

[MPa][bar] [psig]

[MPa][bar] [psig]

LA-45B

LA-80BRated Pressure : 0.15 bar (2.13 psig)(0.015 MPa)

90

100

70

80

60

50

30

40

20

10

LA-60B

0.250.025

0.20.02

90

0.150.015

70

80

60

50

30

40

20

0.10.01

0.0250.020.0150.01

3.562.842.13 1.42

0.250.20.15 0.13.562.842.13 1.42

Rated Pressure : 0.15 bar (2.13 psig)(0.015 MPa)

Air Flow Characteristics

Com

pact

Typ

eM

ediu

m T

ype

Larg

e Ty

peEx

tra

Larg

e Ty

pe

Sketch Drawing and Dimensions Diagram (mm)

0.01 0.015 0.018 0.02 0.025

1.42 2.13 2.56 2.84 3.560.1 0.15 0.18 0.2 0.25

1.42 2.13 2.56 2.84 3.560.1 0.15 0.18 0.2 0.250.01 0.015 0.018 0.02 0.025

Ø26

53

(R/m

in)

Airf

low

(R/m

in)

Airf

low

(R/m

in)

Airf

low

(R/m

in)

Airf

low

(R/m

in)

Airf

low

Airf

low

(R/m

in)

(cfm

)

(cfm

)(c

fm)

(cfm

)(c

fm)

(cfm

)

Discharge pressure

Discharge pressure

Discharge pressure

Discharge pressure

Discharge pressure

Discharge pressure

212

126242

383418

268

407 210

95

130

368

290

46

232

Ø26

307

188

Ø18

100

107

214

196

272

40

If the unit is to be run outside the operating pressure range, consult with your supplier for advice.

DISTRIBUTED BY

09LA03- 1

Specifications and designs are subject to change at any time without notice.

Head Office 9-4, Nakaikegami 2-chome, Ohta-ku, Tokyo 146-8555 JapanPhone : +81-3-3755-1111 Fax : +81-3-3753-8791

E-mail : [email protected] : www.nitto-kohki.co.jp/e

For environmental conservation, this print is made of the pulp blended with waste paper and printed with soy-based inks.® Printed in Japan

5.30

4.59

3.88

4.24

3.18

2.472.83

3.53

4.94

4.59

3.88

4.24

3.18

2.472.121.77

2.83

3.18

2.47

2.12

1.771.41

1.060.710.35

1.77

1.41

1.06

0.71

1.77

2.12

1.41

1.06

0.710.35

2.83

3.183.53

2.47

2.12

1.771.41

1.060.71

2.83

3.53

Rated Pressure : 0.2 bar (2.84 psig)(0.02 MPa)LAM-200

(R/m

in)

Airf

low

(cfm

)

100

150

200

250

300

[MPa][bar][psig] Discharge pressure

0.0250.250.2

0.020.15

0.0150.1

0.01

3.562.840.3

0.03

4.272.131.42

10.59

8.83

5.30

7.06

3.53