Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. Job Name: System Reference: Date: Model: LGH-F470RX5-E1 Capacity............................. 470 CFM / 17 m 3 /min Power Power Source. . . . . . . . . . . . . . . . . . . . 208 - 230V, 1-Phase, 60 Hz Power Consumption ....................... 0.120 - 0.538 kW Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.60 - 2.50 A Starting Current . ................................... 4.5 A Minimum Circuit Ampacity (MCA) ....................... 3.1 A Maximum Overcurrent Protection (MOCP)................. 15 A Controllers PZ-60DR Lossnay ® Controller: Controls 1-15 Lossnay ® units, ON/OFF, Fan Speed, and Vent Mode Operation Mode • Heat Recovery • Bypass • Auto Air Volume (fan speed: extra low - low - high - extra high) @ 208V . . . . . . . . . . . . . . . . . . . . . . . . 147 - 330 - 420 - 470 CFM @ 230V . . . . . . . . . . . . . . . . . . . . . . . . 177 - 365 - 470 - 470 CFM Temperature recovery efficiency (fan speed: extra low - low - high - extra high) @ 208V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 - 74 - 70.5 - 69% @ 230V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 - 72 - 69 - 69% Enthalphy recovery efficiency (fan speed: extra low - low - high - extra high) Heating @ 208V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 - 70 - 66 - 64 % @ 230V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 - 68 - 64 - 64 % Cooling @ 208V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 - 58 - 53 - 51% @ 230V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 - 55 - 51 - 51% External static pressure (In. W.G.) (fan speed: extra low - low - high - extra high) @ 208V . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.07 - 0.33 - 0.54 - 0.80 @ 230V . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.09 - 0.40 - 0.66 - 0.96 External Finish . . . . . . . . . . . . . . . . . . . . . .Galvanized steel sheet Dimensions inches. . . . . . . . . . . . . . . . . . . . .15-3/4 H x 39-1/2 W x 45-1/16 D mm . . . . . . . . . . . .. . . . . . . . . . . . . . . . . 399 H x 1004 W x 1144 D Net Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 lb / 54 kg Energy Transfer. . .. . . . . . . . . . . . . . . . . . . . . . . . . Lossnay ® core Heat Exchange System . . . . . . . . . . . . . . . . . . . . . . . Air-to-air total heat (sensible heat + latent heat) exchange, no moving parts Heat Exchange Material . . . . . . . . . . . . . . . . . . Partition, spacing plate-cellulose fiber membrane Blower . . . . . . . . . . . . . . . . . . . . . . . 9.625 in. dia. centrigugal fan Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Totally enclosed capacitor permanent split-phase induction motor, 4 poles, 2 unit Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Washable fiber (2) Entering Air Temperature Operation Range 14° F to 104° F (-10° C to 40° C), RH 80% or less Sound Pressure Level (fan speed: extra low - low - high - extra high) @ 208V . . . . . . . . . . . . . . . . . . . . . . . . . 18 - 28.5 - 33 - 36 dB (A) @ 230V . . . . . . . . . . . . . . . . . . . . . . . . . 8.5 - 31 - 35.5 - 38 dB (A) ENERGY RECOVERY VENTILATOR GENERAL FEATURES • Lossnay ® cross-flow energy recovery core • Minimal cross contamination (<1% overall) between entering and leaving air streams • Stand-alone control • M-NET • External input bypass damper control • Stand alone or interlocks with all Mitsubishi product SPECIFICATIONS

Upload: others

Post on 03-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Model: LGH-F470RX5-E1 · 2016-09-23 · 140 Selle oled See G 004 Toll Fee: 00-4-4 eo Model: LGH-F470RX5-E1 – DIMENSIONS FORM# LGH-F470RX5-E1 - 201609 LGH-F000600R-E LGH-F00R-E L

Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc.

Job Name:

System Reference: Date:

Model: LGH-F470RX5-E1

Capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . .470 CFM / 17 m3/min Power Power Source. . . . . . . . . . . . . . . . . . . . 208 - 230V, 1-Phase, 60 HzPower Consumption . . . . . . . . . . . . . . . . . . . . . . . 0.120 - 0.538 kWCurrent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.60 - 2.50 AStarting Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5 AMinimum Circuit Ampacity (MCA). . . . . . . . . . . . . . . . . . . . . . . 3.1 AMaximum Overcurrent Protection (MOCP). . . . . . . . . . . . . . . . .15 A

Controllers PZ-60DR Lossnay® Controller: Controls 1-15 Lossnay® units, ON/OFF, Fan Speed, and Vent Mode Operation Mode• Heat Recovery• Bypass• Auto

Air Volume (fan speed: extra low - low - high - extra high) @ 208V . . . . . . . . . . . . . . . . . . . . . . . . 147 - 330 - 420 - 470 CFM @ 230V . . . . . . . . . . . . . . . . . . . . . . . . 177 - 365 - 470 - 470 CFM Temperature recovery efficiency (fan speed: extra low - low - high - extra high) @ 208V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 - 74 - 70.5 - 69% @ 230V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 - 72 - 69 - 69%

Enthalphy recovery efficiency (fan speed: extra low - low - high - extra high) Heating @ 208V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 - 70 - 66 - 64 % @ 230V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 - 68 - 64 - 64 % Cooling @ 208V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 - 58 - 53 - 51% @ 230V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 - 55 - 51 - 51% External static pressure (In. W.G.) (fan speed: extra low - low - high - extra high) @ 208V. . . . . . . . . . . . . . . . . . . . . . . . . . . 0.07 - 0.33 - 0.54 - 0.80 @ 230V. . . . . . . . . . . . . . . . . . . . . . . . . . . 0.09 - 0.40 - 0.66 - 0.96

External Finish . . . . . . . . . . . . . . . . . . . . . .Galvanized steel sheet

Dimensions inches. . . . . . . . . . . . . . . . . . . . .15-3/4 H x 39-1/2 W x 45-1/16 D mm . . . . . . . . . . . .. . . . . . . . . . . . . . . . . 399 H x 1004 W x 1144 D

Net Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 lb / 54 kg

Energy Transfer. . .. . . . . . . . . . . . . . . . . . . . . . . . . Lossnay® core

Heat Exchange System . . . . . . . . . . . . . . . . . . . . . . . Air-to-air total heat (sensible heat + latent heat) exchange, no moving parts

Heat Exchange Material . . . . . . . . . . . . . . . . . . Partition, spacing plate-cellulose fiber membrane

Blower . . . . . . . . . . . . . . . . . . . . . . . 9.625 in. dia. centrigugal fan

Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Totally enclosed capacitor permanent split-phase induction motor, 4 poles, 2 unit

Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Washable fiber (2)

Entering Air Temperature Operation Range14° F to 104° F (-10° C to 40° C), RH 80% or less

Sound Pressure Level (fan speed: extra low - low - high - extra high) @ 208V . . . . . . . . . . . . . . . . . . . . . . . . . 18 - 28.5 - 33 - 36 dB (A) @ 230V . . . . . . . . . . . . . . . . . . . . . . . . . 8.5 - 31 - 35.5 - 38 dB (A)

ENERGY RECOVERY VENTILATOR

LOSSNAY is a perfect combination of heat recovery and ventilation, which is a leading edge product in the ventilation and air-conditioning field.

The LOSSNAY core is a special preserved paper made cross-flow and plate-fin structure, which is referable below.

CITY MULTI can combine LOSSNAY into the air conditioning system, performing the best solution to ventilation and air-conditioning.

LGH-F300RX5-E 300cfm 1-phase 208-230V, 60HzLGH-F470RX5-E 470cfm 1-phase 208-230V, 60Hz

LGH-F1200RX5-E 1200cfm 1-phase 208-230V, 60Hz

Line up of LOSSNAY units

LGH-F600RX5-E 600cfm 1-phase 208-230V, 60Hz

* LGH-F300RX5-E (High fan speed)

Outdoor unit

Remote controller

Indoor unit Indoor unitLossnay

32°F(0°C)

68°F(20°C)

55.6°F(13.1°C)

GENERAL FEATURES

• Lossnay® cross-flow energy recovery core• Minimal cross contamination (<1% overall) between entering and

leaving air streams • Stand-alone control • M-NET• External input bypass damper control• Stand alone or interlocks with all Mitsubishi product

SPECIFICATIONS

Page 2: Model: LGH-F470RX5-E1 · 2016-09-23 · 140 Selle oled See G 004 Toll Fee: 00-4-4 eo Model: LGH-F470RX5-E1 – DIMENSIONS FORM# LGH-F470RX5-E1 - 201609 LGH-F000600R-E LGH-F00R-E L

Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc.

1340 Satellite Boulevard. Suwanee, GA 30024Toll Free: 800-433-4822 www.mehvac.com

Model: LGH-F470RX5-E1 – DIMENSIONS

FORM# LGH-F470RX5-E1 - 201609

LGH-F300,470,600RX5-E1

LGH-F1200RX5-E1

LB K E

D

M

13/16

(20)

M

5 7/

8 ~

9 7/

8(1

50~2

50)

AJ J

øG øH

3 3/

4 (9

5)

NF

C

F

N

Accessory parts• Mounting screws ............................................... x16• Duct connecting flanges ...................................... x4 (double flanges at SA and EA sides)• P-Series - Lossnay connection cable (gray: two wires) ................................................... x1

Unit: Inch (mm)

ModelDimensions Ceiling suspension fixture pitch Nominal

diameterDuct connecting flange Duct pitch

WeightA B C D E F G H J K L M N

LGH-F300RX5-E1 34 15/16(888)

40(1016)

12 3/8(315)

34 1/2(875)

41 7/8(1063)

2 9/16(65)

7 7/8(200)

7 9/16(192)

8 3/16(208)

3 1/8(79)

29 3/8(745)

5 5/16(135.5)

4 7/8(124)

1 3/16(30)

73 lbs(33 kg)

LGH-F470RX5-E1 45 1/16(1144)

39 1/2(1004)

15 3/4(399)

39 3/4(1010)

40 13/16(1036)

15 5/16(389)

9 7/8(250)

9 1/2(242)

10 3/16(258)

3 1/8(79)

27 3/16(690)

6 3/16(157)

6 1/2(165) – 119 lbs

(54 kg)

LGH-F600RX5-E1 45 1/16(1144)

48 1/2(1231)

15 3/4(399)

39 3/4(1010)

49 3/4(1263)

15 5/16(389)

9 7/8(250)

9 1/2(242)

10 3/16(258)

3 1/8(79)

36 1/8(917)

6 3/16(157)

6 1/2(165) – 132 lbs

(60 kg)

EA (exhaust air outlet)

Air exhaust fan

OA (outside air intake)

Core, air filter, High-Efficiency filter, fan, maintenance space

More

than 2

3 5/8

(600)

Position where duct direction change is possible

Air filters

High-Efficiency filter (sold separately) attachment position

Inspection opening

Control boxMaintenance cover

Air supply fan

RA (return air)

SA (supply air)

Bypass damper platePosition where duct direction change is possible

Ceiling suspension fixture (4-1/2” X 13/16” (4-13 X 20) oval)*

Power supply cable opening

*LGH-F470 and F600RX5-E1 types (4-9/16” X 13/16” (4-15 X 20) oval)

39 3/4 (1010)

C DA B

3 1/8 (79)1 3/4 (44)

27 9

/16

(700

) 10

5/8

(270

)

ø9 1

/2(ø

242)

ø10 3

/16(ø

258)

(ø24

2)

(ø25

8)

ø9 1

/2

ø10 3

/16

15 3/4 (399)

31 7/16 (798)

1 1/

8 (2

7)

5 7/

8 ~

9 7/

8(1

50 ~

250

)

4 5/

16 (1

10)

10 5

/8(2

70)

Unit: Inch (mm)Model A B C D Weight

LGH-F1200RX5-E1 48 1/2(1231)

36 1/8(917)

36 1/8(917)

50 1/8(1272)

265 lbs(120 kg)

Accessory parts• Duct connecting flanges ...................................... x4• Mounting screws ................................................ x16• P-Series - Lossnay connection cable (gray: two wires) ................................................... x1

Ceiling suspension fixture (4-9/16 X 1-3/16 (4-15 X 30) oval)

SA (supply air)

RA (return air)EA

(exhaust air outlet)

OA (outside air intake)

Core, air filter, High-Efficiency

filter, fan,

maintenance space

High-Efficiency filter (sold separately) attachment position

Air exhaust fan

Bypass damper plate

Air supply fan

Maintenance cover

Inspection opening

Air filters

More

than 2

3 5/8

(600)

Power supply cableopening

Control box

45 1/16 (1144)

Lossnay core

Lossnay cores