model_fp2000_datasheet.pdf
TRANSCRIPT
Configurable Pressure TransducerModel FP2000
DESCRIPTIONThe FP2000 series is a configurable differential pressure trans-
ducer which allows the customer to select the configuration
which best fits the needs of the application. Choose from mul-
tiple accuracies, outputs, pressure ports, electrical terminations,
and pressure ranges.
The FP2000 is available with gage, absolute, barometric, or
vacuum reference and, best of all, they delivery in two weeks or
less.
FEATURES• mV/V,0Vdcto5Vdc,0Vdcto10Vdc,4mAto20mA
• Gage,absolute,barometric,vacuum
• Differential(wet/wet,wet/dry)
• Intrinsicallysafeoption5
• CEavailable6
FP2000 pressure sensors are custom built from stocked compo-
nents,andmostareshippedin10businessdaysorless.Please
seehttp://measurementsensors.honeywell.comforupdated
listings
Approved Approved
2Honeywell•SensingandControl
Model FP2000PERFORMANCE SPECIFICATIONS
Characteristic Measure
Accuracy1 Seeaccuracytable
Output(selectable) mV/V(seeaccuracytable),0Vdcto5Vdc,0Vdcto10Vdc,or4mAto20mA(twowire)
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -40°Cto116°C[-40°Fto240°F]
Temperature, compensated 4°Cto60°C[40°Fto140°F]2
Temperature, error band 2
0.10%accuracy ±0.5%fullscale
0.25%accuracy ±1.0%fullscale
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Excitation(calibration)
Amplified
(4mAto20mA;0Vdcto5Vdc)
9Vdcto28Vdc
Amplified
(0Vdcto10Vdc) 15Vdcto28Vdc
Unamplified(mV/V) 10Vdc
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media 3 Gas,liquid
Overload - safe
positive(+)direction 4Xfullscaleor3000psi,whichever is less
negative(-)direction 4Xfullscaleor250psi,whichever is less
Overload - burst
positive(+)direction 3000 psi
negative(-)direction 500psi
Pressure port 200%overcapacity
Wetted parts material HaC276&316Lstainlesssteel
TYPICAL SYSTEM DIAGRAM
Customer suppliedChart recorderAlarm panelData acquisitionComputer PLC
In-line amplifiers(Used with unamplified units only)
Amplifier OutputUniversal in-line amplifiersU2W 4 mA to 20 mA (2-wire)
Display unitsSC500 SC2000 SC2001SC3004GM (unamp. only)GM-A (amp. only) NK (unamp. only)HH (unamp. only)
Mating connectors & cablesPT06A-10-6S (option 6a)mV/V - 4 conductor cable4 mA to 20 mA - 3 conductor cable0-5/ 0-10 Vdc - 3 conductor cableStandard DIN 43650 (option 6m) Mini DIN 40050 (option 6n)
Adaptors compatible with:1/4-18 NPT male1/4-18 NPT female7/16-20 UNF male7/16-20 UNF femaleG 1/4 B maleG 1/4 B female
Model FP2000
6q
6r
6a
6n
6m
Honeywell•SensingandControl3
Configurable Pressure TransducerPRESSURE RANGES AND RANGE CODES
psi Range code
torr Range code
mBar Range code
kPa Range code
Bar Range code
inHg
Range code
mmHg
Range code
in H2O
Range code
Gage/Absolute
0.5* AN1* AP2* AR2.5* AS5 AT10 AV15 BJ25 BL30 BM50 BN75 BP100 BR150 CJ200 CL250 CN300 CP400 CQ500 CR600 CS750 CT1000 CV1500 DJ2000 DL2500 DM3000 DN5000 DR6000 DS7500 DT10000 DV
15** HA50** HB135** HC250 HD750 HE1500 HF
35** JA70** JB175** JC350 JD700 JE750 JF1000 JG3500 JH7000 JI10000 JK
2** KA7** KB15** KC35 KD70 KE100 KF200 KG300 KH700 KJ1000 KL1500 KM1700 KN2000 KP3000 KQ5000 KR7000 KS10000 KT15000 KU20000 KV35000 KW50000 KY70000 KZ
0.035** MA0.1** MB0.2 MC0.5 MD1 ME2 MF3.5 NA5 MG7 NB10 MH20 MI30 MJ35 NC50 MK70 ND100 ML135 NE350 NG500 MM700 NH
1** UB2** UD5 UF10 UA15 UC20 UE30 UG50 UI60 UK80 UM100 UP200 UH300 UJ500 UL1000 UN0-32 US16-32 UQ26-32 UR
15** VA50** VB135 VC250 VD750 VE1500 VF
5** WB10** WA20** WC30** WE50** WG100 WI120 WK150 WM200 WP300 WR500 WS
Barometric(Order codeFPB)
0-30 UG16-32 UQ26-32 UR
Vacuum(Order codeFPV)
1 AP5 AT10 AV15 BJ
50 HB135 HC250 HD750 HE
35 JA70 JB175 JC350 JD700 JE750 JF1000 JG
7 KB15 KC35 KD100 KF
0.035 MA0.1 MB0.2 MC0.5 MD1 ME
10 UA20 UE30 UG
15 VA50 VB135 VC250 VD750 VE
10 WA20 WC30 WE50 WG100 WI
Differential(Order codesFDD, FDW)
0.5 AN1 AP2 AR2.5 AS5 AT10 AV15 BJ25 BL30 BM50 BN75 BP100 BR150 CJ200 CL250 CN300 CP400 CQ500 CR600 CS750 CT1000 CV
15 HA50 HB135 HC250 HD750 HE1500 HF
35 JA70 JB175 JC350 JD700 JE750 JF1000 JG3500 JH7000 JI10000 JK
2 KA7 KB15 KC35 KD70 KE100 KF200 KG300 KH700 KJ1000 KL1500 KM1700 KN2000 KP3000 KQ5000 KR7000 KS10000 KT15000 KU20000 KV35000 KW50000 KY
0.035 MA0.1 MB0.2 MC0.5 MD1 ME2 MF3.5 NA5 MG7 NB10 MH20 MI30 MJ35 NC50 MK70 ND
1 UB2 UD5 UF10 UA15 UC20 UE30 UG50 UI60 UK80 UM100 UP200 UH300 UJ500 UL1000 UN0-32 US16-32 UQ26-32 UR
15 VA50 VB135 VC250 VD750 VE1500 VF
5 WB10 WA20 WC30 WE50 WG100 WI120 WK150 WM200 WP300 WR500 WS
*0.5psito2.5psirangesarenotavailableforabsolutepressure**Notavailableinabsolute
4Honeywell•SensingandControl
Model FP2000INTERNAL AMPLIFIERS
Amplifier specifications
Unamplified output: Option 2u
Voltage output: Option 2d
Voltage output: Option 2g
Current two-wire: Option 2p
Output signal Seeaccuracytable 0Vdcto5Vdc 0Vdcto10Vdc 4mAto20mA
Input power (voltage) 10Vdc 9Vdcto28Vdc 15Vdcto28Vdc 9Vdcto32Vdc
Input power (current) 2mA@10Vdc 10mA 15mA 4mAto24mA
Frequency response Naturalfrequency 300 Hz 300 Hz 300 Hz
Power supply rejection N/A 60dB 60dB 60dB
Operating temperature -40°Cto116°C[-40°Fto240°F]
-29°Cto85°C[-20°Fto185°F]
-29°Cto85°C[-20°Fto185°F]
-29°Cto85°C[-20°Fto185°F]
Reverse voltage protection N/A Yes Yes Yes
Short circuit protection N/A Momentary Momentary Yes
Amplifier specifications
Voltage output: Option 2e
Voltage output: Option 2f
Intrinsically safe amp: Option 2n (2N)***
Current two-wire: Option 2y
Output signal 0Vdcto5Vdc 0Vdcto10Vdc 4mAto20mA 4mAto20mA
Input power (voltage) 9Vdcto28Vdc 15Vdcto28Vdc 9Vdcto28Vdc 9Vdcto32Vdc
Input power (current) 10mA 15mA 4mAto24mA 4mAto24mA
Frequency response 2000 Hz 2000 Hz 2000 Hz 2000 Hz
Power supply rejection 60dB 60dB 60dB 60dB
Operating temperature -29°Cto85°C[-20°Fto185°F]
-29°Cto85°C[-20°Fto185°F]`
-29°Cto85°C[-20°Fto185°F]
-29°Cto85°C[-20°Fto185°F]
Reverse voltage protection Yes Yes Yes Yes
Short circuit protection Momentary Momentary Yes Yes
ACCURACY
Non-amplifed output @ 10 Vdc excitation
Gage and absolute Vacuum Barometric Differential
0.10%accuracy 50mV4 25mV 40mV 50mV4
0.25%accuracy 100mV 50mV 80mV 100mV
Honeywell•SensingandControl5
Configurable Pressure TransducerMOUNTING DIMENSIONS
Code 6a: 6-pin, vented, Bendix style
Code 6m: 4-pin, vented, standard DIN (43650)
Code 6n: 4-pin, vented, mini DIN
Code 6q: 4-conductor, vented, integral cable, 1,52 m [5 ft]
Code 6r: 4-conductor, vented, integral cable, conduit fitting 1,52 m [5 ft]
Code 5a1/4-18 NPT female
Code 5b1/4-18 NPT male
Code 5c7/16-20 UNF female
Code 5d7/16-20 UNF male
Code 5fG 1/4 B female
Code 5gG 1/4 B male
Less than 1000 psi
Greater than 1500 psi
Code 5h1/8-27 NPT female
Code 5i1/8-27 NPT male
Code 5pM12-1.5 male
Code 5qM12-1.5 female
Code 5r9/16-18 SAE male
Code 5s9/16-18 SAE female
Less than 1000 psi
Greater than 1500 psi
FPA, FPG, FPB, FPV
FDW FDD
Pressure ports
Electrical termination
6Honeywell•SensingandControl
Model FP2000
Unamplified output: Option 2u
Voltage output: Option 2d/2e
Voltage output: Option 2g/2f
Current two-wire: Option 2p/2y
Intrinsically safe amp: Option 2n (2N)***
Bendix PTIH-10-6P (Option 6a)Noshuntcal A (+)Excitation
B (+)ExcitationC (-)ExcitationD (-)ExcitationE (-)OutputF (+)Output
A (+)SupplyB (-)SupplyreturnC (-)Output0Vdcto 5VdcD (+)OutputE NoconnectionF Noconnection
A (+)SupplyB (-)SupplyreturnC (-)Output0Vdcto 10VdcD (+)OutputVdcE NoconnectionF Noconnection
A (+)SupplyB NoconnectionC NoconnectionD (+)Output4mAto 20mAE NoconnectionF Noconnection
A (+)SupplyB NoconnectionC NoconnectionD (+)Output4mAto 20mAE CasegroundF Noconnection
With shunt cal(option3d)
A (+)ExcitationB (-)ExcitationC (+)OutputD (-)OutputE NoconnectionF ShuntCal
A (+)SupplyB (-)SupplyreturnC (-)Output0Vdcto 5VdcD (+)OutputE NoconnectionF Shuntcal
A (+)SupplyB (-)SupplyreturnC (-)Output0Vdcto 10VdcD (+)OutputE NoconnectionF Shuntcal
A (+)SupplyB NoconnectionC NoconnectionD (+)Output4mAto 20mAE NoconnectionF Shuntcal
A (+)SupplyB NoconnectionC NoconnectionD (+)Output4mAto 20mAE NoconnectionF Shuntcal
Std. DIN 43650 (Option 6m)Noshuntcal 1 (+)Excitation
2 (+)Output3 (-)Output4 (-)Excitation
1 (+)Supply2 (+)Output3 Supply/outputcom.GND Noconnect.tocase
1 (+)Supply2 (+)Output3 Supply/outputcom.GND Noconnect.tocase
1 (+)Supply2 (+)Output4mAto 20mA3 NoconnectionGND Noconnection
1 (+)Supply2 (+)Output3 Case groundGND Noconnection
With shunt cal(option3d)
NotApplicable 1 (+)Supply2 (+)Output3 Supply/outputcom.GND Shuntcal
1 (+)Supply2 (+)Output3 Supply/outputcom.GND Shuntcal
1 (+)Supply2 (+)Output4mAto 20mA3 NoconnectionGND Shuntcal
1 (+)Supply2 (+)Output3 Case ground GND Shuntcal
Mini DIN 40050 (Option 6n)Noshuntcal 1 (+)Excitation
2 (+)Output3 (-)Output4 (-)Excitation
1 (+)Supply2 (+)Output3 Supply/outputcom.GND Noconnect.tocase
1 (+)Supply2 (+)Output3 Supply/outputcom.GND Noconnect.tocase
1 (+)Supply2 (+)Output4mAto 20mA3 NoconnectionGND Noconnectiontocase
1 (+)Supply2 (+)Output3 Case groundGND Noconnection
With shunt cal(option3d)
NotApplicable 1 (+)Supply2 (+)Output3 Supply/outputcom.GND Shuntcal
1 (+)Supply2 (+)Output3 Supply/outputcom.GND Shuntcal
1 (+)Supply2 (+)Output4mAto 20mA3 NoconnectionGND Shuntcal
1 (+)Supply2 (+)Output3 Case ground GND Shuntcal
1.83 m [5 ft] integral cable (Option 6q)Noshuntcal R (+)Excitation
Bl (-)ExcitationG (-)OutputW (+)Output
R (+)SupplyBl (-)SupplyreturnG (-)OutputW (+)Output0Vdcto 5Vdc
R (+)SupplyBl (-)SupplyreturnG (-)OutputW (+)Output0Vdcto 10Vdc
R (+)SupplyBl (+)Output4mAto 20mA
R (+)SupplyBl (+)Output4mAto 20mAW Case ground
With shunt cal(option3d)
NotApplicable R (+)SupplyBl (-)SupplyreturnG ShuntcalW (+)Output0Vdcto 5Vdc
R (+)SupplyBl (-)SupplyreturnG ShuntcalW (+)Output0Vdcto 10Vdc
R (+)SupplyBl (+)Output4mAto 20mAG Shuntcal
R (+)SupplyBl (+)Output4mAto 20mAW Case groundG Shuntcal
Conduit fitting (Option 6r)Noshuntcal R (+)Excitation
Bl (-)ExcitationG (-)OutputW (+)Output
R (+)SupplyBl (-)SupplyreturnG (-)OutputW (+)Output0Vdcto 5Vdc
R (+)SupplyBl (-)SupplyreturnG (-)OutputW (+)Output0Vdcto 10Vdc
R (+)SupplyBl (+)Output4mAto 20mA
R (+)SupplyBl (+)Output4mAto 20mAW Case ground
With shunt cal(option3d)
NotApplicable R (+)SupplyBl (-)SupplyreturnG ShuntcalW (+)Output0Vdcto 5Vdc
R (+)SupplyBl (-)SupplyreturnG ShuntcalW (+)Output0Vdcto 10Vdc
R (+)SupplyBl (+)Output4mAto 20mAG Shuntcal
R (+)SupplyBl (+)Output4mAto 20mAW Case groundG Shuntcal
Note:Forwiringcodes,R=red;Bl=black;W=white;G=green.Colorspecifiescableandletterornumberspecifiesconnection***SeeHoneywell’sWebsite(http://measurementsensors.honeywell.com)formostup-to-dateinformationregardingIntrinsicallySafeapprovalsref.#008-0547-00.
WIRING CODES
Honeywell•SensingandControl7
Configurable Pressure TransducerHow to orderThe FP2000 Order Code isaneasywayforyoutoorderexactlywhatyouwantthefactorytobuild.Simplymakeoneselectionineachofthesixrequiredcategories.Chooseaddersandaccessoriesonlyifyourequirethem.ByvisitingourWebsiteatwww.honeywell.com/sensing you can view complete technical specifications for the FP2000, or click to our on-line shopping site and actually place your order.
Step 1
Transducer type Type Codeo Pressure-gage FPGo Pressure-absolute FPAo Differential-wet/wet FDWo Pressure-barometric FPBo Differential-wet/dry FDDo Pressure-vacuum FPV
Unit typeo psi o baro torr o in Hgo mBar o mm Hgo kPa o in H2O
Step 2
Pressure rangeGage,absolute,anddifferential Range code Range codeo 0.5psi AN o 250psi CNo 1psi AP o 300 psi CPo 2psi AR o 400psi CQo 2.5psi AS o 500psi CRo 5psi AT o 600psi CSo 10psi AV o 750psi CTo 15psi BJ o 1000psi CVo 25psi BL o 1500psi DJo 30psi BM o 2000psi DLo 50psi BN o 2500psi DMo 75psi BP o 3000psi DNo 100psi BR o 5000psi DRo 150psi CJ o 6000psi DSo 200psi CL o 7500psi DT o 10000psi DV
Barometric Vacuumo 16-32inHga UQ o 1psi APo 26-32 in Hga UR o 5psi ATo 0-30inHga UG o 10psi AV o 15psi BJ
Accuracy Accuracycodeo 0.10% 1o 0.25% 2
Step 3
Output Basic Ifadding Ifadding output 9dor9f 1y,3d,9e code (<5000psi) or14co mV/V 2u NA 2uo 5Vdc 2d NA 2eo 10Vdc 2g NA 2fo 4mAto20mA 2p 2n(2N) 2y
NOTE:IfanyADDERSarerequired,theoutputcodemustberevised.Seestep4.
Pressure Port Port codeo 1/4-18NPTfemale 5ao 1/4-18NPTmale 5bo 7/16-20UNFfemale 5co 7/16-20UNFmale 5do G1/4Bfemale 5fo G1/4Bmale 5go 1/8-27NPTfemale 5ho 1/8-27NPTmale 5io M12x1.5male 5po M12x1.5female 5qo 9/16-18UNFSAEmale 5ro 9/16-18UNFSAEfemale 5s
Electrical connector Connector codeo BendixPTIH-10-6P 6ao DIN43650 6mo MiniDIN(40050) 6no Integralpolyurethane5ftcable 6qo 1/2x14NPTconduit5ftcableexit 6r
Step 4
Adders Addercodeo Enhancedthermals 1y Gage:0°Fto180°F Absolute:0°Fto180°F Differential:0°Fto180°F Barometric:30°Fto170°F Vacuum:10°Fto170°Fo Shuntcal 3do ISrating 9do CErating 9eo ISandCErating 9fo Zeroandspanadjustments 14c
o mV/V 2uo 5Vdc 2eo 10Vdc 2fo 4mAto20mA(CEonly) 2yo 4mAto20mA(ISonly 2n(2N)o 4mAto20mA(ISandCE) 2n(2N)
NOTE:Ifyouchooseanyadderoutputfromstep4,youmustrevise your output code selection using this output code chart.ISoutputsavailableonlyonrangesupto5000psi.
AccessoriesMating connectors only Acc.codeo MiniDIN AA161o Bendix AA111
Matingconn.with15ft.cableforBendixconnector(6A) Without With shunt shunt(3d)o mV/V AA113 AA513o 4mAto20mA AA116 AA516o 0to5/0to10Vdc AA117 AA517
Step 5
Example order code FDW 1 CN 2y 5b 6a 1y AA116
Selection Description CodeTransducertype Differentialwet/wet FDWAccuracy 0.10% 1Pressurerange 250psi CNOutput 4mAto20mA 2yPressureport 1/4-18NPTmale 5bElectricaloutputconnections BendixPTIH-10-6P 6aAdders Enhancedtemperaturerange 1yAccessories Matingconnectorwithcable AA116
Theremustbeacodeineachofthesixbasiccodeboxes.Iftherearenoaddersoraccessorieschosen,leavetheboxesblank.
Description Basic code Adder code (see step 4)
Order codeType Accuracy Range Output Pressure Elect.conn. Extended Shuntcal. IS/CErated Pots
Accessorycode
Zeroandspanadjustmentsarelocatedontheside.Seedrawingfordetails.NozeroandspanadjustmentsareavailableonmV/Voutputoption.
008835-2-EN IL50 GLO December 2011Copyright © 2011 Honeywell International Inc. All rights reserved.
Model FP2000 Configurable Pressure Transducer
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com
NOTES1. Accuraciesstatedareexpectedforbest-fitstraightlineforaller-
rors, including linearity, hysteresis, and non-repeatability through zero.
2. For low pressure ranges, temperature effects may vary.3. Thewet/wetdifferentialpressuretransducerhastwoseparate,
weldedHastelloydiaphragms.Inwet/dryunit,thewetport(highport)hasall-weldedstainlesssteelandHastelloyconstruction.Thedryport(lowport)hasnoisolationdiaphragm.
4. Forlowgageanddifferentialpressurerangesat0.10%accuracy,non-amplifiedoutput@10Vdcexcitation=100mV.
5. Rangeuptoandinclude5000psi.6. Notavailablewith6m.
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’sstandardproductwarrantyappliesunlessagreedtootherwisebyHoneywellinwriting;pleaserefertoyourorder acknowledgement or consult your local sales office for specificwarrantydetails.IfwarrantedgoodsarereturnedtoHoneywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specificationsmaychangewithoutnotice.Theinformationwesupply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
WARNINGPERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergencystopdevicesorinanyotherapplicationwherefailureoftheproductcouldresultinpersonalinjury.
Failure to comply with these instructions could result in death or serious injury.
WARNINGMISUSE OF DOCUMENTATION
•Theinformationpresentedinthisdatasheetisforreferenceonly.DONOTUSEthisdocumentasproductinstallationinformation.•Completeinstallation,operationandmaintenanceinformationisprovidedintheinstructionssuppliedwitheachproduct.
Failure to comply with these instructions could result in death or serious injury.
Find out more
Honeywell serves its customers
through a worldwide network of
sales offices, representatives and
distributors. For application as-
sistance, current specifications,
pricing or name of the nearest
AuthorizedDistributor,contactyour
local sales office.
TolearnmoreaboutHoneywell’s
test and measurement products,
call +1-614-850-5000, visit
http://measurementsensors.
honeywell.com, ore-mailinquiries