module 02 intialconfiguration 31 pages

Upload: ryan-belicov

Post on 03-Apr-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    1/31

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    2/312-2nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    3/312-3nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    4/312-4nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    5/31

    The PS Series array can be managed by two methods:

    Command Line Interface (CLI)

    Web Browser

    The CLI is accessible when using the console port directly from the control module serial portor when using Telnet/SSH

    From the console port the following serial connection parameters are required:

    9600 baud

    1 STOP bit

    No parity

    8 data bits

    No hardware flow control

    The Management GUI is accessible using either Internet Explorer, Netscape or Mozilla inconjunction with Java software. With this option, it allows for the management of all memberswithin a group.

    Prior to 4.x firmware the default management configuration allowed you to managethe whole group through a single Well Know Address, WKA, the Group IP address

    Starting with firmware version 4.0 (PS5XXX) an alternative method was created. Thismethod allowed you to create a network management network using eth2 on eachmember with a separate an network management WKA to be used of networkmanagement only traffic.

    Starting with firmware version 4.1, Type 7 controllers are supported (PS6XXX). On Type7 control modules, eth3 can be configured as a management port.

    All members in a group must be at version 4.1 in order for a PS6000 or PS6500 withType 7 control module to join the group.

    Another possible option is SNMP to monitor the PS Series Storage Array.

    The MIBs can be used to monitor trap events and trap thresholds.

    SNMP MIBs are available from the customer support site.

    2-5nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    6/312-6nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    7/31

    Setup program is used to initially configure the PS Series traditionally in a non-

    Microsoft Windows OS environment by asking a series of questions using a terminal

    command line interface resulting in a minimum configuration.

    Host Integration Utility

    Simple SAN Program is a program designed to ensure interoperability withthe storage capabilities in the Windows platform. Windows Server 2003 R2

    has built-in support for SANs.

    Works with vendors to simplify hardware setup. By reducing the setup

    complexity of the individual SAN components, the potential for incorrectly

    configuring the SAN is reduced and the setup documentation is simplified.

    Provides a wizard to configure the PS Series from any Windows platform

    Based on the particular platform, different components will be

    installed

    When used with the Windows Server 2003 platform,

    Integration with two Microsoft services:

    Volume Shadow Copy Service (VSS) enables backup

    operations to use snapshot technology while using

    the Dell EqualLogic hardware provider for VSS

    Virtual Disk Service, VDS, which enables you to use

    Microsoft Storage Manager for SANs to create and

    manage volumes in a PS Series group using the Dell

    EqualLogic hardware provider for VDS

    Integration with the Microsoft iSCSI initiator version 2.x

    2-7nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    8/31

    The steps shown above are the minimum requirements to get the array operational within acustomers network.

    Log in using the default User Name and password, which is grpadmin

    Change or set the devices IP address information based on its requirements

    Initial setup is only accomplished through the serial port using a CLI based setupprogram

    The following minimum parameters must be known to complete the initial setup process

    IP address for Ethernet port 0

    IP Address for the Group

    Group Name

    Member Name

    Managing Group Membership Password

    Group Administration Password

    RAID policy for the member is done using the CLI or the GUI and is not part of theSetup program

    RAID types supported: RAID 6, RAID 5, RAID 10, or RAID 50

    RAID 10 and 50 use 2 spares by default

    RAID 5 and 6 use 1 spare by default

    Spare allocations can be changed to No Spares using the CLI only

    Once the array is set-up, then two methods can be used to manage the PS Series Group orone or more members as a single entity

    Web browser with Java JRE support

    Command line, Telnet or SSH or the console interface

    2-8nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    9/31

    Another way to setup the array is to use the Remote Setup Wizard. The Remote Setup Wizard is

    a program within the Host Integration Tool Kit and is used to configure and set up the array to a

    minimum level. This program allows you to set up the first array and also allows you to add

    subsequent arrays.

    2-9nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    10/312-10nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    11/31

    Host Integration Utility

    The Host Integration Utility is a Dell EqualLogic utility that runs on a Microsoft

    Server, depending on the version depends on what gets installed

    The Remote Setup Wizard allows an administrator to easily and simply:

    Configure a PS Series Array for the first time directly from a Server2003 Wizard

    Connect the server to an already existing PS Series Array

    The utility can be installed on the Server system using the CD that is shipped

    with the array or using the downloaded executable. To install the tools,

    insert the CD into the CD/ DVD drive and then execute the setup.exe file

    Follow the prompts to complete the installation

    Once the program is installed, it will ask if you wish to Initialize a new

    PS Series Storage Array or Add this host to an existing PS Series

    SAN

    If a first time installation of the array, select the first optionInitialize a new PS Series Storage Array

    If adding this server to an existing PS Series SAN, select the

    second option Add this host to an existing PS Series SAN

    If a first time installation, it will then attempt to auto discover the PS

    Series Array and once it is found you can configure the array

    2-11nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    12/312-12nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    13/312-13nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    14/312-14nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    15/31

    Configure the following

    Group name a unique group name within in the SAN

    Group IP Address - a unique IP address for the group within in the SAN, this

    address is used to both connect to the Storage via an initiator and also is it used

    as the Management Well Known Address to manage the group.

    RAID Policy if this is the fist array in the group you can define the RAID policy

    that the array will use. If you are adding an array to an existing group the RAID

    policy option is not available, as shown below, and must be configured within

    Group Manager or the CLI when adding the new member to a pool.

    Admin Password is the Password that the grpadmin user will use to initially

    administer the group, while the membership password is a second password

    that is used when a new member is going to join an already existing group.

    The Chap User information is the CHAP user and password that both the VSS

    and the VDS Dell EqualLogic Providers use to connect to the array.

    2-15nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    16/31

    With RAID10, you tradeoff maximizing redundancy, provides good performance, but is thecostliest as it minimizes your capacity. RAID10 has the best performance for small randomwrites (where small is less than 64KB), but has relatively similar performance to other RAID

    types for sequential writes and all reads. RAID10 is going to provide no performance impactwhen degraded, and the most minimal impact due to reconstruction. It also has the fastest

    reconstruction. In order for RAID10 to fail, both halves of a mirrored pair would have to failbefore reconstruction completed, so it is the safest. The only real downside to using RAID10, isthe capacity tradeoff to provide you optimal performance.

    RAID50 is a pair of striped RAID5 sets, so now uses two disk's-worth of capacity to parity. Its

    fairly equivalent to R10 for sequential writes and reads, as well as random reads. However, onsmall random writes, it takes longer due to needing to read the stripe, compute the parity, then

    rewrite the stripe, but with R50 the stripe is only half the disks that it is for R5. RAID50 canhandle a second drive failure while degraded ONLY if the failure occurs on the non-degradedRAID5 set. So, it has better safety than a single RAID5 set across the same set of disks (the

    chance of RAID failure due to

    RAID6, this is similar to RAID5, but has double the parity. This uses two disk's-worth of capacity,and provides for any two disk failing, even before the first failure's rebuild completes. However,

    there are a couple of performance characteristics to be aware of. The small random writes,which were slow with RAID5, are a bit slower, due to the double-parity calculation. The rebuildtime, with a single-failure is equivalent to RAID5, as well as the "degraded" performance with a

    single failure. But if you have a double-failure (before the first failure's rebuild has completed),you will see a larger performance impact and a longer-rebuild time.

    With RAID5, you are maximizing capacity (basically donating one disk's-worth of capacity to

    parity), but the protection is one parity stripe against the entire RAID set, so it can only handleone failure, and has the longest rebuild time. And while degraded, it has the worst IOperformance characteristics. Also, small random writes have a poor characteristic on this RAID

    type, since it needs to read the entire stripe, recalculate parity, and write the changes to thestripe again.

    2-16nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    17/312-17nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    18/31

    To create a new volume:

    Click Volumes in the leftmost column to manage volumes.

    Click Create Volume in the Activities pane.

    2-18nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    19/31

    Step 1 of 3 General Volume Settings

    Name: Provide a unique name, up to 64 alphanumeric characters, used to

    identify the volume for administrative purposes.

    Size: Enter a value for the volume size and select the unit (by default, GB) .

    Leave all other values at default for now.

    Step 2 of 3 Space Reserve Settings

    Specify the size of the volume in MB or GB.

    For now, do not specify Thin Provisioned Volume.

    Step 3 of 3 iSCSI Access settings

    Specify who can access this volume by:

    CHAP user name.

    IP address or range of addresses.

    In this example, the IP address of a server has been specified

    iSCSI name.

    To prevent inadvertent sharing, all volumes and snapshots created beginning

    with V4.0 are configured by default to disallow connections from more than one

    iSCSI qualified name (IQN). In practice, this prevents connections from multiple

    initiators, assuming (as is the best practice) that all the initiators on a single

    server use the same IQN.

    You should enable shared access on specific volumes and snapshots, if your

    environment coordinates writes properly; for example in cluster environments,

    VMware ESX environments, etc.

    2-19nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    20/312-20nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    21/312-21nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    22/312-22nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    23/31

    In order to see the iSCSI targets available to this host, we must first locate the iSCSI

    targets by specifying the discovery address. To do this perform the following functions:

    Launch the Microsoft iSCSI initiator.

    Select Discovery tab.

    Select Add to create a target portal entry.

    Create a target portal entry for the Dell EqualLogic PS Series SAN solution (use

    the Group IP address).

    2-23nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    24/31

    Next, perform the actual target discovery:

    1.Select the Targets tab.

    2.Press the Refresh button.

    3.A list of iSCSI targets will appear. Only targets that this host is authorized to

    use will be listed.

    2-24nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    25/31

    Logging on to the iSCSI target will make the volume visible to this host. To log on to the

    target:

    From the Targets tab, highlight the target you will attach.

    Press the Log On button.

    When Log On to Target appears, select Automatically restore this connection

    when the system reboots and press OK.

    Select the Persistent Targets tab and confirm that the iSCSI name of the target

    is listed.

    2-25nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    26/31

    From the Bound Volumes/Devices tab, select Bind All .

    2-26nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    27/31

    Prepare new volume for use:

    Right-click on My Computer.

    Select Disk Management.

    The Initialize and Convert Disk Wizard will launch automatically, if it

    does not appear follow the steps list below:

    Press Next to continue.

    When the Select Disks to Initialize window appears, ensure that the

    disk you wish to initialize is selected.

    IMPORTANT: When the Select Disks to Convert to Dynamic.

    Windows Servers 2003 and 2003 R2 appears, does NOT

    support use of Dynamic Disks with the iSCSI initiator.

    Windows Servers 2008 and 2008 R2 appears, does support use

    of Dynamic Disks with the iSCSI initiator.

    If the Initialize and Convert Disk Wizard does not launchautomatically:

    Select the disk from the disk/ volume list.

    Select in the gray box area, where the disk ID is shown, and

    right click.

    Select Initialize to initialize the disk as a basic disk.

    2-27nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    28/31

    Dynamic disks :

    Windows Servers 2003 and 2003 R2 appears, does NOT support use of

    Dynamic Disks with the iSCSI initiator.

    Windows Servers 2008 and 2008 R2 appears, does support use of Dynamic

    Disks with the iSCSI initiator.

    The utilities used to align sectors cannot be used on dynamic disks.

    Microsoft Windows Server 2003 clustering does not support dynamic disks.

    2-28nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    29/31

    1.The new disk will appear as Unallocated.

    2.Right-click on the shaded area and select New Partition.

    When prompted, assign a drive letter to the partition.

    When prompted, format the disk. Use the Perform a Quick Format option.

    2-29nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    30/31

    The SAN-based storage will appear to the OS and the user as a directly attached disk.

    Proceed as normal to use the disk (file storage, etc.).

    2-30nitial Configuration of the PS Series Array

  • 7/28/2019 Module 02 Intialconfiguration 31 Pages

    31/31