monarch electrical control system for elevator · 2019. 3. 12. · software burning terminal...

6
Suzhou Inovance Technology Co., Ltd. Address: No.16 Youxiang Road, Yuexi, Wuzhong District, Suzhou Tel.: (0512) 6637 6666 Fax: (0512) 6285 6720 Customer service: 400-777-1260 http://www.inovance.com MONARCH electrical control system for elevator Content may be changed due to continuous product upgrade without further notice. Copyright Shenzhen Inovance Technology Co., Ltd. V0.0 Code:L6210128

Upload: others

Post on 25-Sep-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MONARCH electrical control system for elevator · 2019. 3. 12. · Software burning terminal Technical Specifications-Used as a power supply without a contact switch or encoder to

Suzhou Inovance Technology Co., Ltd.Address: No.16 Youxiang Road, Yuexi, Wuzhong District, Suzhou Tel.: (0512) 6637 6666Fax: (0512) 6285 6720 Customer service: 400-777-1260http://www.inovance.com

MONARCH electrical control system for elevator

Content may be changed due to continuous product upgrade without further notice.Copyright   Shenzhen Inovance Technology Co., Ltd.

V0.0Code:L6210128

Page 2: MONARCH electrical control system for elevator · 2019. 3. 12. · Software burning terminal Technical Specifications-Used as a power supply without a contact switch or encoder to

01/02

New Electrical Accessory Solution 3rd Generation Control Cabinet

Product Code

Advantages of Inovance Solution

Product Dimensions

Product Features3 Safer■ All power circuits are protected by RCDs (GB7588.1).

4 Compliant with New Standards ■ The standard configuration includes UCMP and the

door lock short circuit detection and door bypass functions. The space for installing a filter board is provided to address the EMC requirements specified in GB7588.1.

1 More Cost-Effective ■ The new solution features 30% less traveling cable cores than

conventional products and requires only 10 cores for connection between the car top box and a car, significantly reducing the cost of electrical accessory components.

2 Slimmer■ It is 20% smaller than a conventional control cabinets.

N I C E 3 0 0 0 - B - 40 15 - ANICE3000 integrated controller

Cabinet type

Voltage level

Power level

Model

Dimensions of a control cabinet (machine room) Dimensions of a control cabinet (machine-room-less)

Type5.5 - 15 kw18.5 - 22 kw30 - 37 kw

Dimensions (mm) 970 x 430 x 2201220 x 470 x 2501320 x 510 x 275

Installation ModeWall-mounting/Floor Floor standingFloor standing

Type5.5 - 22 kw30 - 37 kw

Dimensions (mm) (Excluding Resistance Box)350 x 240 x 1350mm400 x 250 x 1500mm

Machine room Machine-room-less

① Control cabinet② Car top box③ Car board

A Traveling cable B Car cable

MR

Hositway

Car

A

B

LeadingThe control cabinet complies with the standard that requires UCMP and provides the door lock short circuit detection and door bypass functions.It meets the EMC requirements specified in GB7588.1.

Streamlined30% less traveling cable cores are required.60% less cores are required between the car top box and a car.

SafeAll power circuits of the control cabinet are protected by RCDs. The car operating panel contains no heavy current control circuit, so as to prevent electric shocks.

Easy to InstallThe D5G display board allows automatic/semi-automatic floor address setting, which helps significantly reduce the installation and commissioning time. (One hour can be saved for every 30 floors.)

MultifunctionalAll functions to be used in a car are available, including car display, IC card management, intercom, voice announcement, light and fan control, and floor control.

Page 3: MONARCH electrical control system for elevator · 2019. 3. 12. · Software burning terminal Technical Specifications-Used as a power supply without a contact switch or encoder to

03/04

WISE900 Door Operator Integrated Controller

■ Integrated closed-loop synchronous/asynchronous motor control■ Ultra-slim design and supreme HMI■ IP21 protection and noiseless operation■ Communication control for efficiency and safety■ One-key commissioning and automatic curve generation for better ease of use■ Door vane distance learning and more accurate and smoother operation curves■ Intensive protection including overvoltage/undervoltage protection, overcurrent protection,

inter-phase shortcircuit protection, output phase loss protection, and anti-pinch upon power failure■ Self-adaptive holding torque to dynamically maintain the door system balance

Product FeaturesTerminal Wiring Description

External Circuit Configuration Description

Product Code

Dimensions

Main circuit terminals

Control circuit terminals

W I S E 900 -S- 0P4Product series Voltage level Power level

39180

4-φ4.5

132

125

170

Label

L, N

U, V, W

Name

Single-phase power input terminal

Output terminal

Grounding terminal

Description

Single-phase 220 VAC power supply input terminal

For connecting to a three-phase motor

Grounding

Controller Model

WISE900-S0P4

Air Switch (A)

16

Contactor

10

Main Circuit Cable (mm2)

2.5

Terminal

CAN

PG&DI

Terminal for the manufacturer

Type

CAN

Internal 24 V

Encoder input

Digital input

Software burning terminal

Label

CAN+

CAN-

XCM

+24 V

COM

PGA

PGB

PGZ

D11-D12

USB

Function

CAN communication with the car top board

Connecting to an external 24 V power supply

24 V power supply common

A phase of encoder

B phase of encoder

Z signal of encoder

Digital signal input

Software burning terminal

Technical Specifications

-

Used as a power supply without a contact switch or encoder to output a maximum current of 200 mA

Isolated from GND inside

Open-circuit output or push-pull output of collector

Input for isolation by the opticalcoupler, active when the level is low Input voltage scope: 0 VDC - 30 VDC

-

Page 4: MONARCH electrical control system for elevator · 2019. 3. 12. · Software burning terminal Technical Specifications-Used as a power supply without a contact switch or encoder to

05/06

Integrated Car Top Box

Product Features

Product Overview

1 Integration of all car top box functions■ Integration of all car top box functions such as call, light,

maintenance, car top control, and door operator control (optional)

2 Advanced HMI■ Black acrylic HMI to display DI/DO status

3 Grand light assembly■ Car top lighting, car lighting, and emergency lighting to

meet the requirement of GB7588 & EN81-20

1. Simple Integration of the controller and IC card reader to facilitate installation and use and reduce the cost

2. SafeUnique password for each IC card IC card duplication prevention to effectively protect users Dedicated to encryption locksPairing up IC cards with encryption locks so that each IC card can only be used with specified elevators

3. Compliant with New StandardsCompliant with the TSG T7007-2016 elevator conformance testing rules and the requirements in amendment 2 of the TSG T7001-2009 elevator supervision and regular inspection rules

4 Strongly magnetic maintenance handle■ Comfortable, easy to fetch and return, and flexible

5 Compact■ Highly integrated, brilliant design, and easy to maintain

Product Dimensions

Product Dimensions

■ Model: MCTC-CTW-A3■ Dimensions: 352 mm x 265 mm x 135 mm (H x W X D)

310.

0

355.

5

225.0

265.0 130.0132.6

140.2

IC Card Products

Product Features

Product Family

104 .0101 .090 .0

80.0

77.0

66.0

Ø 5.5

27 .424 .422 .4

R 3.25

Product Product Model FunctionCar call controller MCTC-IC-A Including the MCTC-IC-A controller and MCTC-IC-G1 antenna

Car call controller with a password keypad MCTC-IC-A2 MCTC-IC-A substitute with a password keypad

Rear floor card reader antenna MCTC-IC-G Used to detect card reading at the rear door of through-type door

IC card maker MCTC-IC-W Connected to a host controller for making dedicated IC cards

IC card dongle MCTC-IC-L Connected to a host controller for encrypting host controller software

IC cardMCTC-IC-C White card

MCTC-IC-C2 Key chain

MCTC-IC-A/G integrated controller

MCTC-IC-A2 controller with a password keypad

Page 5: MONARCH electrical control system for elevator · 2019. 3. 12. · Software burning terminal Technical Specifications-Used as a power supply without a contact switch or encoder to

07/08

Physical Dimensions

Product Code

Model Selection

Connecting Terminals

ARD conformance testing report

MCTC - ARD - C - 40 - 15Elevator-dedicated

optional componentOptional

component typeVoltage

level Power

level

■ Easier to use: Modular designs of the MONARCH platform ‒ dedicated ARD-C and NICE series for higher maintainability■ More reliable: Redundancy protection for more reliable performance■ Smarter: Smart battery management for excellent durability Accurate self-diagnostics for quicker fault location

Product Features

Automatic Rescue Device (ARD) for Elevator Emergency EvacuationMCTC-ARD-C Series

Product ModelGross Weight

(kg)

MCTC-ARD-C-4015MCTC-ARD-C-2015MCTC-ARD-C-4030MCTC-ARD-C-2030

W(mm)

A(mm)

H1(mm)

B(mm)

D(mm)

248.0

303.0

217.0

272.0

383.4

383.4

H2(mm)

480.0

480.0

430.0

430.0

151.2

151.2

15

17

MCTC-ARD-C-4015MCTC-ARD-C-2015MCTC-ARD-C-4030MCTC-ARD-C-2030

248.0

303.0

217.0

272.0

383.4

383.4

431.7

431.7

99.0

99.0

151.2

151.2

15

17

W

A

H2 B H1

D

Front view Left view① Wall-mounting

W

H2 H1

A

D

B

Front view Left view② Floor standing

Wall-mounting

Floor standing

Type Terminal Symbol Terminal Description Function

Mai

n po

wer

term

inal

s PE

Three-phase AC power input terminalNL1L2L3R

ARD output terminalSTN

Cont

rol w

irin

g te

rmin

als

Y1 Emergency running startup signalM1Y2 Phase sequence shorting signalM2

DI1 Emergency running completion signal

DI2 Forced rescue signal

COM GND signalCANH CAN communicationCANL

DI3 Main air switch opening and rescue stop signal

COM GND signal

The mains power is connected to terminals L1, L2, L3, and N1 of the ARD. Terminals R, S, T, and N of the ARD are connected to the elevator control cabinet.Note 1: Do not connect the power input cables to the output terminalsR, S, T of the ARD. Otherwise, the ARD will be damaged.Note 2: The door operator is connected to the 220 V main power supply. K1 and K2 of the main board S1 are turned to the ON position. The door operator is connected to terminals R and N.

ON when the ARD enters emergency running state OFF when the ARD exits emergency running state

Effective when the level is low (0 V - 0.8 V) or the passive switch is closedAfter receiving this signal, the ARD considers that emergency running is completed, stops output, and exits the emergency running state. If the ARD does not receive this signal, it automatically stops output after running for three minutes.

When the switch of the drive board is closed and the DI2level is 0 V - 0.8 V or the passive switch is closed, the ARD forcibly outputs this signal. Generally, this signal is used for electrical brake release.

Common signal terminalConnected to the CN3 terminal of the main control board of the control cabinet for CAN communicationConnected to the auxiliary contact of the main air switch to open the switch and stop rescue Effective when the level is low (0 V - 0.8 V) or the passive switch is closedCommon signal terminal

Product ModelW

(mm)A

(mm)H1

(mm)H2

(mm)B

(mm)D

(mm)Gross Weight

(kg)Wall-mounting

MCTC-ARD-C-4003

248.0 217.0 383.4 480.0 430.0 151.2 15

MCTC-ARD-C-2003MCTC-ARD-C-4007MCTC-ARD-C-2007MCTC-ARD-C-4015MCTC-ARD-C-2015MCTC-ARD-C-4018

303.0 272.0 383.4 480.0 430.0 151.2 17MCTC-ARD-C-2018MCTC-ARD-C-4030MCTC-ARD-C-2030

Floor standingMCTC-ARD-C-4003

248.0 217.0 383.4 431.7 99.0 151.2 15

MCTC-ARD-C-2003MCTC-ARD-C-4007MCTC-ARD-C-2007MCTC-ARD-C-4015MCTC-ARD-C-2015MCTC-ARD-C-4018

303.0 272.0 383.4 431.7 99.0 151.2 17MCTC-ARD-C-2018MCTC-ARD-C-4030MCTC-ARD-C-2030

Page 6: MONARCH electrical control system for elevator · 2019. 3. 12. · Software burning terminal Technical Specifications-Used as a power supply without a contact switch or encoder to

The Active Front End (AFE) implements DC-AC conversion and stabilizes the bus voltage. Energy from the motor side is returned to the grid through the AFE for reuse by other electrical devices, so as to save energy.

Elevator ‒ Dedicated AFEEfficient Energy Recovery and Regeneration

NICE 9000 Elevator Integration Controller

Product Features

Product Features

Product Code

Product Code

Product Dimensions Product Dimensions

Green■ Power factor > 0.99, THD < 5%, operating noise < 59 dB,

significantly reducing noises for the grid and ambient environment

Highly Reliable■ Machine service life of over 10 years

Compliant with New Standards■ First of its kind to comply with the TSG T7007-2016

Conformance Testing Rules

■ Four-quadrant technology to achieve a minimum form factor with a given power Compliant with EMC requirements without an external filter

■ Unique low power consumption standby technology: When an elevator is out of operation for a long period of time, it may enter standby state with a standby power consumption of less than 5 W.

■ Better safety assurance Change from closed-loop control to open-loop control for safe stop and passenger unloading

■ STO, SBC, and electronic shorting motor stator contactor technologies TUV-certified and SIL3-certified

Optional elevator integration controller component

AFE series Power level

MCTC - AFE - 40 - 18 N

Voltage level

N: Four-quadrant model R: Energy feedback model

NICE series integrated controller

N I C E - L J R - 4 0 1 1 - A 8

40: Three-phase 380 V50: Three-phase 480V

JR: NICE9000 four-quadrant JX: NICE9000 two-quadrant

L: Elevator integration E: Escalator integration D: Door operator integration

07:7.5 kW11:11 kW15:15 kW18:18 kW22:22 kW30:30 kW

A0: Supports STO + electronic shorting motor stator contactor Supports the low power consumption standby function A4: Supports STO + electronic shorting motor stator contactorA8: Supports the low power consumption standby function A12: Not support STO + electronic shorting motor stator contactor

Power level (kW)

4005: 5.5

4007: 7.5

4011: 11

4015: 15

4018: 18.5

4022: 22

4030: 30

Declaration of Conformity According to

the Low Voltage Directive 2014/35/EU the Electromagnetic Compatibility Directive 2014/30/EU

We, Suzhou Inovance Technology Co., Ltd. Address: No.16, Youxiang Road, Yuexi Town, Wuzhong District, Suzhou 215104,

P.R.China hereby declare that the Products : AFE(Active Front End) Model Designation : Refer to the Annex Model Designation

the product (s) listed above are in conformity with the essential requirements of the EC Directive(s) mentioned above when installed in accordance with the installation instructions contained in the product documentation and manufactured in accordance with the European harmonised standards:

Standard Number Title Identifier

EN 61800 -5-1:2007 Adjustable speed electrical power drive systems - safety requirements ‒ electrical, thermal and energy

EN 12015:20 14 EN 12016:20 13

Electromagnetic compatibility: Product family standard for lifts, escalators and moving walks -Immunity Electromagnetic compatibility: Product family standard for lifts, escalators and moving walks -Emission

The product (s) must be installed only by professional assemblers who are familiar with the requirements for safety and EMC. The assembler is responsible for ensuring that the end product or system complies with all the relevant laws in the country where it is to be used. Refer to user manual.

A ffixing of CE -marking: 15 Responsible for making this declaration is the manufacturer. Person responsible for making this declaration

Name, Surname: Ridley Lee

Position/Title: Deputy Director, R&D

Signature:

Date: 2015-12-29

W

A

HB

D W

A

H B

D

AFE ModelDimensions Bracket Mounting

Hole LocationHole

Diameter Gross Weight

(kg)

MCTC-AFE-4005XMCTC-AFE-4007XMCTC-AFE-4011XMCTC-AFE-4015XMCTC-AFE-4018XMCTC-AFE-4022XMCTC-AFE-4030X

Currently, the standard models support only three-phase 380 V power supplies. If 200 V and 500 V power supplies are used, consult us so that we can address your requirement using non-standard models.

H(mm)

505

W(mm)

260

D(mm)

171

A(mm)

160

B(mm)

490

Φ(mm)

7.0

405 215 165 160 390 7.0

365 200 153

D1(mm)

161

142

121 160 350 6.08.58.79.014.014.818.220.0

PowerDimensions Mounting

Hole LocationHole

Diameter Gross Weight

(kg)

7.5 kW to 11 kW15 kW to 18.5 kW22 kW to 30 kW

H(mm)

W(mm)

D(mm)

A(mm)

B(mm)

Φ(mm)

400450495

210250320

150170195

150150250

385430480

6.56.56.5

111827

09/10