monarch electrical control system for elevator · 2019. 3. 12. · software burning terminal...
TRANSCRIPT
Suzhou Inovance Technology Co., Ltd.Address: No.16 Youxiang Road, Yuexi, Wuzhong District, Suzhou Tel.: (0512) 6637 6666Fax: (0512) 6285 6720 Customer service: 400-777-1260http://www.inovance.com
MONARCH electrical control system for elevator
Content may be changed due to continuous product upgrade without further notice.Copyright Shenzhen Inovance Technology Co., Ltd.
V0.0Code:L6210128
01/02
New Electrical Accessory Solution 3rd Generation Control Cabinet
Product Code
Advantages of Inovance Solution
Product Dimensions
Product Features3 Safer■ All power circuits are protected by RCDs (GB7588.1).
4 Compliant with New Standards ■ The standard configuration includes UCMP and the
door lock short circuit detection and door bypass functions. The space for installing a filter board is provided to address the EMC requirements specified in GB7588.1.
1 More Cost-Effective ■ The new solution features 30% less traveling cable cores than
conventional products and requires only 10 cores for connection between the car top box and a car, significantly reducing the cost of electrical accessory components.
2 Slimmer■ It is 20% smaller than a conventional control cabinets.
N I C E 3 0 0 0 - B - 40 15 - ANICE3000 integrated controller
Cabinet type
Voltage level
Power level
Model
Dimensions of a control cabinet (machine room) Dimensions of a control cabinet (machine-room-less)
Type5.5 - 15 kw18.5 - 22 kw30 - 37 kw
Dimensions (mm) 970 x 430 x 2201220 x 470 x 2501320 x 510 x 275
Installation ModeWall-mounting/Floor Floor standingFloor standing
Type5.5 - 22 kw30 - 37 kw
Dimensions (mm) (Excluding Resistance Box)350 x 240 x 1350mm400 x 250 x 1500mm
Machine room Machine-room-less
① Control cabinet② Car top box③ Car board
A Traveling cable B Car cable
MR
Hositway
Car
①
②
③
A
B
LeadingThe control cabinet complies with the standard that requires UCMP and provides the door lock short circuit detection and door bypass functions.It meets the EMC requirements specified in GB7588.1.
Streamlined30% less traveling cable cores are required.60% less cores are required between the car top box and a car.
SafeAll power circuits of the control cabinet are protected by RCDs. The car operating panel contains no heavy current control circuit, so as to prevent electric shocks.
Easy to InstallThe D5G display board allows automatic/semi-automatic floor address setting, which helps significantly reduce the installation and commissioning time. (One hour can be saved for every 30 floors.)
MultifunctionalAll functions to be used in a car are available, including car display, IC card management, intercom, voice announcement, light and fan control, and floor control.
03/04
WISE900 Door Operator Integrated Controller
■ Integrated closed-loop synchronous/asynchronous motor control■ Ultra-slim design and supreme HMI■ IP21 protection and noiseless operation■ Communication control for efficiency and safety■ One-key commissioning and automatic curve generation for better ease of use■ Door vane distance learning and more accurate and smoother operation curves■ Intensive protection including overvoltage/undervoltage protection, overcurrent protection,
inter-phase shortcircuit protection, output phase loss protection, and anti-pinch upon power failure■ Self-adaptive holding torque to dynamically maintain the door system balance
Product FeaturesTerminal Wiring Description
External Circuit Configuration Description
Product Code
Dimensions
Main circuit terminals
Control circuit terminals
W I S E 900 -S- 0P4Product series Voltage level Power level
39180
4-φ4.5
132
125
170
Label
L, N
U, V, W
Name
Single-phase power input terminal
Output terminal
Grounding terminal
Description
Single-phase 220 VAC power supply input terminal
For connecting to a three-phase motor
Grounding
Controller Model
WISE900-S0P4
Air Switch (A)
16
Contactor
10
Main Circuit Cable (mm2)
2.5
Terminal
CAN
PG&DI
Terminal for the manufacturer
Type
CAN
Internal 24 V
Encoder input
Digital input
Software burning terminal
Label
CAN+
CAN-
XCM
+24 V
COM
PGA
PGB
PGZ
D11-D12
USB
Function
CAN communication with the car top board
Connecting to an external 24 V power supply
24 V power supply common
A phase of encoder
B phase of encoder
Z signal of encoder
Digital signal input
Software burning terminal
Technical Specifications
-
Used as a power supply without a contact switch or encoder to output a maximum current of 200 mA
Isolated from GND inside
Open-circuit output or push-pull output of collector
Input for isolation by the opticalcoupler, active when the level is low Input voltage scope: 0 VDC - 30 VDC
-
05/06
Integrated Car Top Box
Product Features
Product Overview
1 Integration of all car top box functions■ Integration of all car top box functions such as call, light,
maintenance, car top control, and door operator control (optional)
2 Advanced HMI■ Black acrylic HMI to display DI/DO status
3 Grand light assembly■ Car top lighting, car lighting, and emergency lighting to
meet the requirement of GB7588 & EN81-20
1. Simple Integration of the controller and IC card reader to facilitate installation and use and reduce the cost
2. SafeUnique password for each IC card IC card duplication prevention to effectively protect users Dedicated to encryption locksPairing up IC cards with encryption locks so that each IC card can only be used with specified elevators
3. Compliant with New StandardsCompliant with the TSG T7007-2016 elevator conformance testing rules and the requirements in amendment 2 of the TSG T7001-2009 elevator supervision and regular inspection rules
4 Strongly magnetic maintenance handle■ Comfortable, easy to fetch and return, and flexible
5 Compact■ Highly integrated, brilliant design, and easy to maintain
Product Dimensions
Product Dimensions
■ Model: MCTC-CTW-A3■ Dimensions: 352 mm x 265 mm x 135 mm (H x W X D)
310.
0
355.
5
225.0
265.0 130.0132.6
140.2
IC Card Products
Product Features
Product Family
104 .0101 .090 .0
80.0
77.0
66.0
Ø 5.5
27 .424 .422 .4
R 3.25
Product Product Model FunctionCar call controller MCTC-IC-A Including the MCTC-IC-A controller and MCTC-IC-G1 antenna
Car call controller with a password keypad MCTC-IC-A2 MCTC-IC-A substitute with a password keypad
Rear floor card reader antenna MCTC-IC-G Used to detect card reading at the rear door of through-type door
IC card maker MCTC-IC-W Connected to a host controller for making dedicated IC cards
IC card dongle MCTC-IC-L Connected to a host controller for encrypting host controller software
IC cardMCTC-IC-C White card
MCTC-IC-C2 Key chain
MCTC-IC-A/G integrated controller
MCTC-IC-A2 controller with a password keypad
07/08
Physical Dimensions
Product Code
Model Selection
Connecting Terminals
ARD conformance testing report
MCTC - ARD - C - 40 - 15Elevator-dedicated
optional componentOptional
component typeVoltage
level Power
level
■ Easier to use: Modular designs of the MONARCH platform ‒ dedicated ARD-C and NICE series for higher maintainability■ More reliable: Redundancy protection for more reliable performance■ Smarter: Smart battery management for excellent durability Accurate self-diagnostics for quicker fault location
Product Features
Automatic Rescue Device (ARD) for Elevator Emergency EvacuationMCTC-ARD-C Series
Product ModelGross Weight
(kg)
MCTC-ARD-C-4015MCTC-ARD-C-2015MCTC-ARD-C-4030MCTC-ARD-C-2030
W(mm)
A(mm)
H1(mm)
B(mm)
D(mm)
248.0
303.0
217.0
272.0
383.4
383.4
H2(mm)
480.0
480.0
430.0
430.0
151.2
151.2
15
17
MCTC-ARD-C-4015MCTC-ARD-C-2015MCTC-ARD-C-4030MCTC-ARD-C-2030
248.0
303.0
217.0
272.0
383.4
383.4
431.7
431.7
99.0
99.0
151.2
151.2
15
17
W
A
H2 B H1
D
Front view Left view① Wall-mounting
W
H2 H1
A
D
B
Front view Left view② Floor standing
Wall-mounting
Floor standing
Type Terminal Symbol Terminal Description Function
Mai
n po
wer
term
inal
s PE
Three-phase AC power input terminalNL1L2L3R
ARD output terminalSTN
Cont
rol w
irin
g te
rmin
als
Y1 Emergency running startup signalM1Y2 Phase sequence shorting signalM2
DI1 Emergency running completion signal
DI2 Forced rescue signal
COM GND signalCANH CAN communicationCANL
DI3 Main air switch opening and rescue stop signal
COM GND signal
The mains power is connected to terminals L1, L2, L3, and N1 of the ARD. Terminals R, S, T, and N of the ARD are connected to the elevator control cabinet.Note 1: Do not connect the power input cables to the output terminalsR, S, T of the ARD. Otherwise, the ARD will be damaged.Note 2: The door operator is connected to the 220 V main power supply. K1 and K2 of the main board S1 are turned to the ON position. The door operator is connected to terminals R and N.
ON when the ARD enters emergency running state OFF when the ARD exits emergency running state
Effective when the level is low (0 V - 0.8 V) or the passive switch is closedAfter receiving this signal, the ARD considers that emergency running is completed, stops output, and exits the emergency running state. If the ARD does not receive this signal, it automatically stops output after running for three minutes.
When the switch of the drive board is closed and the DI2level is 0 V - 0.8 V or the passive switch is closed, the ARD forcibly outputs this signal. Generally, this signal is used for electrical brake release.
Common signal terminalConnected to the CN3 terminal of the main control board of the control cabinet for CAN communicationConnected to the auxiliary contact of the main air switch to open the switch and stop rescue Effective when the level is low (0 V - 0.8 V) or the passive switch is closedCommon signal terminal
Product ModelW
(mm)A
(mm)H1
(mm)H2
(mm)B
(mm)D
(mm)Gross Weight
(kg)Wall-mounting
MCTC-ARD-C-4003
248.0 217.0 383.4 480.0 430.0 151.2 15
MCTC-ARD-C-2003MCTC-ARD-C-4007MCTC-ARD-C-2007MCTC-ARD-C-4015MCTC-ARD-C-2015MCTC-ARD-C-4018
303.0 272.0 383.4 480.0 430.0 151.2 17MCTC-ARD-C-2018MCTC-ARD-C-4030MCTC-ARD-C-2030
Floor standingMCTC-ARD-C-4003
248.0 217.0 383.4 431.7 99.0 151.2 15
MCTC-ARD-C-2003MCTC-ARD-C-4007MCTC-ARD-C-2007MCTC-ARD-C-4015MCTC-ARD-C-2015MCTC-ARD-C-4018
303.0 272.0 383.4 431.7 99.0 151.2 17MCTC-ARD-C-2018MCTC-ARD-C-4030MCTC-ARD-C-2030
The Active Front End (AFE) implements DC-AC conversion and stabilizes the bus voltage. Energy from the motor side is returned to the grid through the AFE for reuse by other electrical devices, so as to save energy.
Elevator ‒ Dedicated AFEEfficient Energy Recovery and Regeneration
NICE 9000 Elevator Integration Controller
Product Features
Product Features
Product Code
Product Code
Product Dimensions Product Dimensions
Green■ Power factor > 0.99, THD < 5%, operating noise < 59 dB,
significantly reducing noises for the grid and ambient environment
Highly Reliable■ Machine service life of over 10 years
Compliant with New Standards■ First of its kind to comply with the TSG T7007-2016
Conformance Testing Rules
■ Four-quadrant technology to achieve a minimum form factor with a given power Compliant with EMC requirements without an external filter
■ Unique low power consumption standby technology: When an elevator is out of operation for a long period of time, it may enter standby state with a standby power consumption of less than 5 W.
■ Better safety assurance Change from closed-loop control to open-loop control for safe stop and passenger unloading
■ STO, SBC, and electronic shorting motor stator contactor technologies TUV-certified and SIL3-certified
Optional elevator integration controller component
AFE series Power level
MCTC - AFE - 40 - 18 N
Voltage level
N: Four-quadrant model R: Energy feedback model
NICE series integrated controller
N I C E - L J R - 4 0 1 1 - A 8
40: Three-phase 380 V50: Three-phase 480V
JR: NICE9000 four-quadrant JX: NICE9000 two-quadrant
L: Elevator integration E: Escalator integration D: Door operator integration
07:7.5 kW11:11 kW15:15 kW18:18 kW22:22 kW30:30 kW
A0: Supports STO + electronic shorting motor stator contactor Supports the low power consumption standby function A4: Supports STO + electronic shorting motor stator contactorA8: Supports the low power consumption standby function A12: Not support STO + electronic shorting motor stator contactor
Power level (kW)
4005: 5.5
4007: 7.5
4011: 11
4015: 15
4018: 18.5
4022: 22
4030: 30
Declaration of Conformity According to
the Low Voltage Directive 2014/35/EU the Electromagnetic Compatibility Directive 2014/30/EU
We, Suzhou Inovance Technology Co., Ltd. Address: No.16, Youxiang Road, Yuexi Town, Wuzhong District, Suzhou 215104,
P.R.China hereby declare that the Products : AFE(Active Front End) Model Designation : Refer to the Annex Model Designation
the product (s) listed above are in conformity with the essential requirements of the EC Directive(s) mentioned above when installed in accordance with the installation instructions contained in the product documentation and manufactured in accordance with the European harmonised standards:
Standard Number Title Identifier
EN 61800 -5-1:2007 Adjustable speed electrical power drive systems - safety requirements ‒ electrical, thermal and energy
EN 12015:20 14 EN 12016:20 13
Electromagnetic compatibility: Product family standard for lifts, escalators and moving walks -Immunity Electromagnetic compatibility: Product family standard for lifts, escalators and moving walks -Emission
The product (s) must be installed only by professional assemblers who are familiar with the requirements for safety and EMC. The assembler is responsible for ensuring that the end product or system complies with all the relevant laws in the country where it is to be used. Refer to user manual.
A ffixing of CE -marking: 15 Responsible for making this declaration is the manufacturer. Person responsible for making this declaration
Name, Surname: Ridley Lee
Position/Title: Deputy Director, R&D
Signature:
Date: 2015-12-29
W
A
HB
D W
A
H B
D
AFE ModelDimensions Bracket Mounting
Hole LocationHole
Diameter Gross Weight
(kg)
MCTC-AFE-4005XMCTC-AFE-4007XMCTC-AFE-4011XMCTC-AFE-4015XMCTC-AFE-4018XMCTC-AFE-4022XMCTC-AFE-4030X
Currently, the standard models support only three-phase 380 V power supplies. If 200 V and 500 V power supplies are used, consult us so that we can address your requirement using non-standard models.
H(mm)
505
W(mm)
260
D(mm)
171
A(mm)
160
B(mm)
490
Φ(mm)
7.0
405 215 165 160 390 7.0
365 200 153
D1(mm)
161
142
121 160 350 6.08.58.79.014.014.818.220.0
PowerDimensions Mounting
Hole LocationHole
Diameter Gross Weight
(kg)
7.5 kW to 11 kW15 kW to 18.5 kW22 kW to 30 kW
H(mm)
W(mm)
D(mm)
A(mm)
B(mm)
Φ(mm)
400450495
210250320
150170195
150150250
385430480
6.56.56.5
111827
09/10