Sensors and Instruments Remote and local signaling High visibility indicator No external derivator is required Easy installation and maintenance Hot swapping for network board and solenoid coil Ex Several models of solenoid valve IP66 Protection Class product line * valve monitor Remote signaling through a electronic board or by an industrial network SV Series Valve Monitor Internal or external mounting of the solenoid coil

Upload: others

Post on 20-Aug-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

Sensors and Instruments

Remote and local signaling

High visibility indicator

No external derivator isrequired

Easy installation andmaintenance

Hot swapping for networkboard and solenoid coil

Ex

Several models of solenoid valve

IP66 Protection Class

product line * valve monitor

Remote signaling through a electronic board or byan industrial network

SV Series Valve Monitor

Internal or externalmounting of the solenoidcoil

Page 2: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

Code Key

Important: Not all combinations presented above are possible, we recommend contacting our engineering applications or access www.sense.com.br to forma workable combination for the selected product.

SV N - 1 1 P - A C - ASI3.2 - BS - VSSA - Ex /ZFunctionSV - valve monitor with aluminum housing

Local Signaling_ - With yellow and black open/ closed signalerN - no local signalling

Area Classification_ - General PurposeEx - Classified Area

Internal Derivator_ - No internal moduleA - ASI-interface derivatorD - DeviceNet derivatorP - Profibus DP derivator

Actuator of Derivator_ - No magnetic atuactor of derivatorC - With magnetic atuactor of derivator

Remote Signalling by NetworkASI3.2 - ASI3.2-SV-2EH-2ST moduleDNB - DNB-SV-2EH-2ST moduleDP - DP-SV-2EH-2EC-2ST module

Coil TypesBS - Internal coil General PurposeBSI - Internal coil Intrinsic SafetyBSM -Iinternal coil Increased Safety

Valve BodyVSSA - standard valve 1/4" BSP aluminumVSSX - standard valve 1/4" BSP aluminum

Main Cable Input1 - 2 threaded holes ½" NPT2 - 2 threaded holes M203 - 2 threaded holes 3/4" NPT5 - 2 threaded holes PG13.56 - 2 threaded holes PG16V1 - Connector M12 male of 5 pinsVY - Connector AS-Interface

Eoptional Cable Input_ - No extra input1 - 1 threaded holes PG92 - 2 threaded holes PG93 - 3 threaded holes PG9

Cable Gland_ - Without cable glandP - With plastic cable gland installed

Conventional Remote SignalingRD - SV-2RD-2DS module2E2 - SV-2E2-2DS module2E - SV-2E-2DS module2N - SV-2N-2DS module

Customization/Zx - This field will be used by application engineering. 'X' is a numeric digit (code) defined by the EA.

1

Page 3: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

roti

no

M e

vla

V

gnilangiS et

ome

Rslani

mret htiw detcetorp xob noitcenno

C - srosnes cinortcele detaluspacne hti

w noitacidnI -noisrev srosnes tcatno

C yrD dna ru

maN ,

NP

N ,P

NP -

seludoM kro

wteN lairtsu

dnI

subiforP

PD ,snoisrev ecafretnI-

SA 0.3 dna 1.2 ,0.2 -

lioc trohs ro nepo timsnart nac skro

wten teNecive

D dnamorf scitsongaid egatlov hgih ro

wol dna dionelos.gnilangis rof sdel dna stib atad ,kro

wten

lanretnI

rotavireD

eht swolla taht rotavired lanretni hti

w deilppus eb nac tIdionelos eht fo dna draob kro

wten eht fo tnemecalper

no neve krowten eht fo tser eht ffo gnire

wop tuohtiw

.)1 enoZ( serehpsomta evisolpxe yllaitnetop

gnila

ngi

S lacoLnoitacidni diulf / desolc ro nepo -

.gnilaes xob eht gnisaercni sixa lanretxe -

tupnI elba

C"4/3 -"2/1 - 02

M - 61G

P - 5.31G

P :sdaerhTx

E ro esopruP larene

G :dnalg elbaC

talF iS

A ,.21M :srotcenno

C3 rof noitpo dna stupni 2 :ledo

M dradnatS

stupni yrailixua

.sessecorp lairtsudni ynam ni deilppa eb nac tI .sevlav evitator rof

metsyS noita

motuA

2

sevlaV

dio

nelo

S

esneS

SV

esneS

anretnI edi

ónel

oS anibo

B

lareneG

esuoruP

m xE

0,6W

i xE

Page 4: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

Conception

The valve monitor is the industrial automation equipmentthat has been applied in a large scale for industrial networksbecause it provides a great reduction of costs with a simpleproject, assembly (electric and mechanic), operation andmaintenance. It had been developed to automatize rotating valves orpneumatic actuators, as much in general purpose installationas in industrial networks .

The new valve monitoring system is assembled in analuminum box (soon in stainless steel and plastic). Itintegrates a local and remote valve signaling through anelectronic board (PNP, NPN, NAMUR, dry contact or industrialnetwork) and a low power solenoid valve (plastic, brass,aluminum and also in instainless steel).

Valve Monitorfor rotative pneumatic

actuator

The valve monitoring system was designed for valve

automation allowing:

Local signaling: Indicates the valve status (open or closed position) and activates the positioning sensors, installedin the network board, allowing the total adjustment of the activation angles of the two sensors.

Remote Signaling: The electronic board with outputsPNP, NPN, Exi Namur and dry contact. On industrialnetwork applications the boards send the valve statusposition and receive the command to activate thesolenoid through the network.

Smart tap: Eliminating the assembling accessories suchas cables, connectors and tap boxes. Allows the networkcable to get in and off the equipment through screwedterminals and also allows the replacement of the networkboard and of the solenoid without powering off the rest of the network. On Ex version, after removing the coverfrom the enclosure, the smart tap automatically poweroff the network board even on potentially explosiveatmospheres.

Solenoid valves: The housing has an adapter boardallowing different solenoid suppliers to be used butalways keeping the solenoid coil protected inside the box.

Housing: Electrostatic painting aluminum has IP66protection degree and two cable glands (three othersoptional cable glands).

Page 5: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

The monitor can be provided without local visual indication

mainly when the local has hard access for the operators. It´s

installed directly in the axis of the valve or pneumatic actuator.

It has the actuators to activate the sensors that indicate the

valve remote position.

The monitor can be provided with a high visibility localindicator installed in the axis of the valve or in the pneumaticactuator indicating the valve open or closed position. It hastwo actuators to activate the sensors that indicate the valveremote position.

Type No Local Visual Indication With Local Visual Indication (open / closed)

Application for actuators with 30x80mm holes for actuators with 30x80mm holes

Shaftdiameter

<42mm <42mm

Shaftheight

30mm, 20mm (plus adapter) 30mm, 20mm (plus adapter)

Standardkit

1 magnetic target without local indication tomount on the shaft M6 x 35mm screws

1 adapter for shaft of 20 mm of height

1 local visual indicator to mount on the shaft with magnetictargets

1 M6 x 55mm screw

1 adapter for shaft of 20 mm of height

The monitor is assembled with internal electronic board that make possible to indicate the valve opening and closing.Through of anexclusive rotative system that allows the adjustment of switching point without any tool. The activator is connected directly on theshaft of the pneumatic actuator shaft or directly in the valve and it has as function to activate the local indicator and the sensors forremote indication. The adjustment is made turning the activator to the right or left depending on the rotation of the actuator.

No visual indicator Visual indicator

Local Visual Signaling

Remote Signaling

Signaling ModulesThe signaling modules incorporate the sensors of the remotesignaling. Hall-effect transistors are assembled in theelectronic circuit protected by the resin that fills all thehousing.Buy network:ASI3.2 - Standard : ASI3.2-SV-2EH-2ST with 2 additional inputs: ASI-3.2-SV-2EH-2EC-2STDN-B - Devicenet: DN-B-SV-2EH-2EC-2STDP - Profibus: DP-SV-2EH-2EC-2STGeneral purpose:2RD - Reed: SV-2RD-2DS2E2 - PNP: SV-2E2-2DS2E - NPN: SV-2E-2DS2N - Namur: SV-2N-2DSNote: Contact our Application Engineering for others models

4

Page 6: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

SV-2E-2DS SV-2E2-2DS SV-2RD-2DS SV-2N-2DS

Power supply 24Vdc 24Vdc - -

Consumption (except theoutputs)

< 20 mA < 20 mA - < 5 mA

Protection thermal thermal - -

Signaling - - - -

Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur

Activated sensor magnetic magnetic magnetic magnetic

Signaling led yellow led yellow - -

Angle/ Histeresys/ Repeatability ~35º / <7º / <0.3º

Outputs 2 2 2 2

Switching voltage 10 - 30 Vdc 10 - 30 Vdc < 250 Vac/ Vdc 8.5 Vdc

Max. switching current 100 mA 100 mA < 3 A -

Output drop voltage < 2.5 V < 2.5 V - -

Output protection thermal thermal - -

Output signaling 2 yellow leds 2 yellow leds -

Housing thermoplastic box

Circuit protection sealed with resin

Connection pressure terminals 2.5mm2

Mounting fixed by two screws

Operation temperature -20oC to +55oC

Class protection according to monitor box model

Label BR Ex em II T6

Certified number Ex-039/2002X

General purpose signaling modules The valves signaling modules were developed to automatize rotating valves, mainly with 1/4 turn (90o) pneumatic actuators.They have basically two sensors that detect the open and closed valve position and the indication is made by a Local indicator.

This technology is based on the traditional inductive proximity sensors with high repeatability and reliability without mobile parts, operating per many years without faults and also in hard environments with chemical agents, humidity, vibration, dust, eg.

Mechanical Dimensions

87

SENSOR 2

SENSOR 1

ON BOARDSENSOR

Sensor 1

Sensor 2

5

Technical Specifications

tu

pnI

sro

sn

eS

stu

ptu

Oel

ud

oM

Page 7: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

C E P E LINMETRO

CEPEL-Ex-039/2002XBR Ex em T6II

SENSOR 2

SENSOR 1

ON BOARDSENSOR

Sensores e Instrumentos

SV-2RD-2DS-Ex

VALVE MONITOUR2 REED SENSOR

CONFIGURATION:

Ex emU<250Vdc/VacPower<100W

IL<3A

-S2

- -S1

-

S2

+

S1

+ -S2

-

S1

--

S2

+

S1

+

SOLENOID IN SOLENOID OUT

NANA CC

www.sense.com.br

MADE IN BRAZIL

C E P E LINMETRO

CEPEL-Ex-039/2002XBR Ex em T6II

SENSOR 2

SENSOR 1

ON BOARDSENSOR

Sensores e Instrumentos

www.sense.com.br

SV-2N-2DS-Ex

VALVE MONITOUR2 HALL SENSOR

2 NAMUR OUTPUT

CONFIGURATION:

Ex emU=8Vdc

IL<1mA= ON IL>3mA= OFF

SENSOR2 1

-- +-- +-

S2

- -S1

-

S2

+

S1

+ -S2

-

S1

--

S2

+

S1

+

SOLENOID OUT SOLENOID IN NAMUR-2 NAMUR-1

MADE IN BRAZIL

Electrical Connections

NPN Module PNP Module

Reed Module Namur Module

Instalation options

Connection with two cables Connection with one cable

There are two installation possibilities of the valve monitors being one using two cables and another with a multicable. In the first option the cables are connected from input and output PLC card to the monitor through of two cable glands.The second option isused only one cable connected from input and output PLC card to the monitor through of one cable gland.

6

-S2

- -S1

-

S2

+

S1

+ -S2

-

S1

--

S2

+

S1

+

NPN

(O

UT-

2)

NPN

(O

UT-

1)

SOLENOID OUT SOLENOID IN

V- -

V+

C E P E LINMETRO

MADE IN BRAZIL

CEPEL-Ex-039/2002XBR Ex em T6II

SENSOR 2

SENSOR 1

ON BOARDSENSOR

Sensores e Instrumentos

SV-2E-2DS-Ex

VALVE MONITOUR2 HALL SENSOR

2 TRANSISTOR OUTPUT

CONFIGURATION:

Ex em10<U<30V

Un=24VIL<100mA

SENSOR2 1

www.sense.com.br

C E P E LINMETRO

CEPEL-Ex-039/2002XBR Ex em T6II

SENSOR 2

SENSOR 1

ON BOARDSENSOR

Sensores e Instrumentoswww.sense.com.br

SV-2E2-2DS-Ex

VALVE MONITOUR2 HALL SENSOR

2 TRANSISTOR OUTPUT

CONFIGURATION:

Ex em10<U<30V

Un=24VIL<100mA

SENSOR2 1

-S2

- -S1

-

S2

+

S1

+ -S2

-

S1

--

S2

+

S1

+

PN

P (

OU

T-2

)

PN

P (

OU

T-1

)

SOLENOID OUT SOLENOID IN

V- -

V+

MADE IN BRAZIL

Page 8: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

Remote Signaling by NetworkThe network signalling modules are perfect for valves automation because they can transmit through an cable the open or closed state of the valve and it can receive the commands for activating the solenoid. The low power valve can be connected directly onthe network . Another advantage of the network system is the possibility of the module to transmit diagnostics mainly ofshort-circuit or when the solenoid coil is openned. The modules are available in AS-Interface, DeviceNet and DP Profibusversions.

Network PCB Function

Through the network it is possible to send the valve signalingstate and receive the command to activate the outputs that may use the network power line to activate the solenoid coil thatmoves the actuator.

The network PCBs replace the remote signaling sensors. HallEffect transistors are assembled on PCB module encapsulatedby a resin that fills all the housing.

The PCB module is available for AS-Interface, Devicenet and DP Profibus protocols and allows besides the remote signaling thevalve activation, offering easy connection through screwedterminals, leds for sensor outputs signaling and by networkstatus.

TopologyTopology is the common term used to illustrate the way of connection among the network instruments. There are several typesof topology therefore some of them are applied in a specific network. See below some examples.

Line Branch Line

Star Ring

AS-Interface AS-Interface

7

Page 9: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

IO = 7h ID = Ah

ID2 = Eh

Data DeviceNet DP Profibus AS-Interface

General Purpose DN-B-SV-2EH-2EC-2ST DP-SV-2EH-2EC-2ST ASI3.2-SV-2EH-2EC-2ST

Ex Version DN-B-SV-2EH-2EC-2ST-Ex

DP-SV-2EH-2EC-2ST-ExASI3.2-SV-2EH-2EC-2ST-Ex

Power Supply 24 Vdc ± 20% 24 Vdc ± 20% 30.5 Vdc

Consumption < 35 mA < 55 mA < 35 mA

Protection reversal and short-circuit

Signaling through network led two color led green led

Sensors Signaling sensors for closed or open valves

Activating through magnetic activator mounting in the local indicator

Angle / Histeresys /Repeatability

~35º /< 7º / < 0.3º

Signaling 2 yellow leds

Number of outputs 2 independent outputs

Switching voltage 24 Vdc by network 24 Vdc by network 24 Vdc

Switching current 50 mA per output 50 mA per output 50 mA per output

Ex switching current 50 mA per output 50 mA per output 50 mA per output

Output drop voltage < 2.5 Vdc < 1.7 Vdc < 2.5 Vdc

Output protection electronic short-circuit

Watch dog de-energized output in the communication fault

Output signaling 2 yellow leds

Addressing network 0 to 63 1 to 99 1 to 31 A or B

Transmission rate 125, 250 or 500Kbit/s up to 1.5Mbit/s ASI standard

Communication type polled master / slave master / slave

Transmitted data Tx = 1 byte / Rx = 1 byte Tx = 1 byte / Rx = 1 byte 4 bits input / 2 bits output

Diagnostics open or closed output and power supply open or closed output

Network signaling two color led two color led green led

Housing thermoplastic box

Circuit protection sealed with resin

Connection 2.5mm2 pressure terminals

Mounting fixed by two screws

Operation temperature -20ºC to + 55ºC

Protection class according to monitor box model

Network Commons Specsel

ud

oM

stu

ptu

Osr

os

ne

Syl

pp

uS r

ew

oP

Mechanical Dimensions

kro

wte

N

87

SENSOR 2

SENSOR 1

ON BOARDSENSOR

Sensor 1

Sensor 2

8

Page 10: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

DeviceNetDeviceNet industrial network is a low level network that allows the communication since the simplest equipment as I/O modules, sensors and actuators up to the most complex devices as programmable logical controllers (PLCs) and microcomputers.DeviceNet is based on CAN protocol (Controller Area Network) developed by Bosh in 80s originally for automobile application.Later it was adapted to use in the industrial processes due to the excellent performance reached in automobile manufacturers.

In fact in a vehicle we have all the critical characteristics that we find in an industry as a high temperature, humidity,electromagnetic noises and at the same time that we need a high response speed and reliability therefore the airbag and theABS brake are directly involved with the risk of human lives.

The CAN Protocol defines the MAC ID code (Media Access Control) in an exclusive priority system that does not lose datas in case of collisions, therefore the device with the less priority detects the dominant one and waits the conclusion of the transmission.

Several control types are used in the communication frame being possible to detect data errors (CRC); check acknowledge(ACK), frame errors (FORM) among others. DeviceNet is very versatile and supported by vendors around of the world thatmanufacture a lot of equipments like intelligent sensors, interfaces, etc.

This way Devicenet is a stable network designed to meet the performance and reliability requirements of the industrialenvironment tecnology working in the most intelligent way.

Example of topology Network terminator

The terminator must be installed in the beginning and in theend of the network between wires white and blue.

Cable Length

Cable type Cable functionTransmission rate

125 Kbits/ s 250 Kbits/ s 500 Kbits/ s

Thick cable Trunk line 500 m 250 m 100 m

Thin cable Trunk line 100 m

Flat cable Trunk line 380 m 200 m 75 m

Thin cable Branch line 6 m

Thin cable Σ Branch line 156 m 78 m 39 m

Nota: The DeviceNet network supports up to 64 nodes.

Cable type : Signal + Power Supply

Thin cable Thick cable Flat cable

9

120120

1/4W1/4W

Page 11: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

The valve monitors to DeviceNet network have diagnostics of short or opening solenoid indicating the fault locally through of thenetwork led.

The module also allows the bits visualization in the DeviceNet configuration software. Below see the table with the meaning of eachbit.

DN-B-SV-2EH-2EC-2ST - Led's, Bits and Diagnostics

Input Output

Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7 Bit 0 Bit 1

Sensor 1 Sensor 2 CM 1 CM 2 Output 1 Output 2 ST 1 ST 2 Sol 1 Sol 2

Hall Sensor Mechanical Contact Short or Open Status Solenoid

Status 1 Status 2 Voltage module

0 1 VDN < 21.6V

1 0 21.6V ≤ VDN <22.8V

0 1 22.8V ≤ VDN < 27.6V

Input Bits

Bit Working description Signaling Leds Bit to PLC

0 Activated Sensor 1 S1- 0 - sensor 1 deactivated

yellow 1 - sensor 1 activated

1 Activated Sensor 2 S2- 0 - sensor 2 deactivated

yellow 1 - sensor 2 activated

2 CM1 input closed CM 1- 0 - contact 1 open

yellow 1 - contact 1 closed

3 CM2 input closed CM 2- 0 - contact 2 open

yellow 1 - contact 2 closed

4output #1 status, SOL 1 led indicate

short or open outputSOL

1

yellow blinking 1 - output 1 in short or open

according to output bit 0 0 - output 1 normal

5output #2 status, SOL 2 led indicate

short or open outputSOL

2

yellow blinking 1 - output 2 in short or open

according to output bit 1 0 - output 2 normal

6 Power Supply status --

see the table above-

7 Power Supply status --

-

Output Bits

Bit Working description Signaling Leds Bit to PLC

0 Output # 1statusSOL

1

- 0 - deactivated output #1

yellow 1 - activated output # 1

1 Output # 2 statusSOL

2

- 0 - deactivated output #2

yellow 1 - activated output #2

Note: The short output indication is showed by output leds and only will work when the respective output is activated.

MADE IN BRAZIL

BUSSENSOR2 1

SENSOR 2

SENSOR 1

ON BOARDSENSOR

Sensores e Instrumentoswww.sense.com.br

DN-B-SV-2EH-2EC-2ST

VALVE MONITOUR2 HALL SENSOR

2 MECHANICAL CONTACT2 TRANSISTOR OUTPUT

V+

CA

NH

GN

D

CA

NL

V-

IN DEVICENET

OUTPUT2 1

RD

WH

Sh

ield

BU

BK

+-- -- +

YE

RD

YE

RD

TRANSISTOROUTPUTI<100mA

EXT. SOLENOID 2 1

MECHANICAL CONTACT

2 1

NO

NO

C C

87

65

43

21 ON

BAUD RATES7-S8:125-250-500 Kbps

SETTING

ADDRESSS1-S6:00 A 63

CONFIGURATION:

OUTPUTS

DEVICENET NETWORK21,6<U<26,4V

Un=24VI<35mA

-5ºC<Temp<+55ºC

U<26,4VI<50mA x 2

10

Page 12: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

The Profibus network allows the communication between devices of different manufacturers without any special adjustment. Itcan be used in real time applications (with the active PLC) that require high speed or in complex communication tasks. There are three functional communication protocols (communication Profiles): PA, DP and FMS. The profile of DPcommunication is more frequently used and its optmized to high speed, efficiency, low cost, linking the communication betweenautomation systems and distributed peripherals.If DP is used instead of the conventional 4..20mA technology are sumed up to more than 40% the cost saving. DP Profileapplication is indicated to substitute the parallel transmission, which is used in the industrial automation, as for the analogicaltransmission in the automatized process. DP has been designed for fast data exchange at field level. Data exchange with thedistributed devices is primarily cyclic. The upper level devices (such as PLC/PC or Process Control Systems ) communicate between the field distributed devices (suchas drivers, valves, I/Os or transducers) through of serie connections. The I/O data exchange between field devices are cyclicaland the configuration data exchange is acyclic. DP Profibus allows to establish connections up to 127 slaves however some addresses already are busy.The address 0 is used foreventual programming tool, address 126 is used for a default slave and the address 127 is reserved for broadcast transmission (not used when in the network there is just one master) where an active station sends a message (not confirmed) to all the other active stations (masters and slaves). Thus 125 possible addresses are remained (from 1 to 125).The addressing for Sense monitors is limited to the 99 addresses. The transmission technology is the RS-485 that is able to reach up to 15km of distance depending on the communication rate with repeaters.

DP Profibus Network

Example of topology Network Terminator

Re

pe

tid

or

The terminador must be installed in the end of each segment and must be powered with 5Vdc:

Cable Length

A line

B line

GND

390

220

+5 V

390

Terminator

Baud Rate (Kbit/ s) 9.6 19.2 93.75 187.5 500 1500 12000

Max. branch length 1200 m 1200 m 1200 m 1000 m 400 m 200 m 100 m

Note: The Profibus network admits up to 127 active stations connected in the fieldbus.

Cable Type: Signal and Power Supply

2-wire 4-wire

11

Page 13: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

DP-SV-2EH-2EC-2ST - Led's, Bits and Diagnostics The valve monitors to DP Profibus network have diagnostics of short and opening solenoid and power supply, indicating the faultthrough of the network leds.

Input Output

Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 0 Bit 1

Sensor 1 Sensor 2 CM 1 CM 2 Power Supply Output 1 Output 2 Sol 1 Sol 2

Hall Sensor Mechanical ContactUnder or Overvoltage

< 19V or > 29VShort or Open Solenoid

The module also allows the visualization of the bits in the configuration software of DP Profibus network. See in the table below themeaning of each bit.

MADE IN BRAZIL

CEPEL-Ex-039/2002X

PWR DPSENSOR2 1

SENSOR 2

SENSOR 1

ON BOARDSENSOR

Sensores e Instrumentoswww.sense.com.br

DP-SV-2EH-2EC-2ST

VALVE MONITOR2 HALL SENSOR

2 MECHANICAL CONTACT2 TRANSISTOR OUTPUT

V+

BGN

D

AV-

IN DP

ADDRESS OUTPUT2 1

3 9

Range: 01 to 99

X1 X10

32

BN

YE

/RD

Sh

ield

GN

WH

+-- -- +

54

109

87

6 54

32

109

87

6

YE

RD

YE

RD

TRANSISTOROUTPUTI<100mA

EXT. SOLENOID 2 1

MECHANICAL CONTACT

2 1

NO

NO

C C

CONFIGURATION:

OUTPUTS

DP NETWORK19<U<29V

I<55mAUn=24V

-5ºC<Temp<+55ºC

U<29VI<50mA x 2

12

Input Bits

Bit Working description Signaling Leds Bit to PLC

0 Activated Sensor 1 S1- 0 - deactivated output #1

yellow 1 - activated sensor 1

1 Activated Sensor 2 S2- 0 - deactivated sensor 2

yellow 1 - activated sensor 2

2 CM1 closed CM 1- 0 - contact 1: open

yellow 1 - contact 1: closed

3 CM2 closed CM 2- 0 - contact 2: open

yellow 1 - contact 2: closed

4Power Supply state undervoltage

<19V - Overvoltage >29VPW

red 0 - under or overvoltage

verde 1 - normal power supply

5output state 1

PW LED indicate the output stateshort or open

PWred 0 - output # 1 short or open

green 1 - output # : normal

6output state 2

PW LED indicate the output stateshort or open

PWred 0 - output # 2: short or open

green 1 - output # 2: normal

Output Bits

Bit Working description Signaling Leds Bit to PLC

0 Output # 1 stateSOL

1

- 0 - deactivated output #1

yellow 1 - activated output # 1

1 Output # 2 stateSOL

2

- 0 - deactivated output #2

yellow 1 - activated output #2

Note: The short output indication is showed by PW led and only will works when the respective output is activated.

Page 14: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

AS-Interface is a low cost connection system developed to operate through of the 2-wire cable which also supplies the power and digital communication in a distance up to 100m that can be extended with repeaters/expanders.

Especially indicated for low levels in the the process automation with simple field devices such as keys, proximity sensors,auxiliary contacts, solenoids valves, contactors, etc. where they need to operate in isolated local and controlled by PLC or PC.

The AS-Interface network is the best substitution for the traditional wire architectures. One special chip was developed to beused to the module or devices connections having assured the low cost and the robust performance.

AS-Interface (AS-i) means Actuator-Sensor Interface and is the simplest solution of an industrial automation network. It is ideal for sensors and actuators to work in a network automation system. This bus is an efficient alternative to connect all thedevices to the controller using only one pair of wires. The efficiency by a network can be improved through the thousands ofproducts and a lot of available applications.

The network installation without a previous project takes the bad operational results becaming the correction of the networkmistakes hard therefore the bases had not been observed.

All the future functionality by AS-i network starts with a previous and detailed project showing all the connection instruments onthe bus with all the specificationss like model, tag, physical localization, inputs, outputs and the network branching.

AS-Interface

Network Topology

Cable type

Flat cable Round cable

AS-Interface cables:

Flat cable - The yellow flat cable is standard for AS-i network. It has a specified geometric section and transmits at the sametime data and power supply to the sensors.

Round cable - Sense developed a round cable that has the same electric caracteristics (section, impedance and capacitance)that allows the network installation with the same 100 m of length. It must be used to connect the equipment of certifiednetwork for using in hazardous areas.

13

Page 15: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

ASI3.2-SV-2EH-2EC-2ST - Led's, Bits and Diagnostics The valve monitors to AS-Interface network have short and open diagnostics for the solenoid (only with activated output) indicating the fault through the network led.

Input Output

Bit 3 Bit 2 Bit 1 Bit 0 Bit 1 Bit 0

CM 2 CM 1 Sensor 2 Sensor 1 Sol 2 Sol 1

Mechanical Contact Hall Sensor Solenoid

Led Functions

Led Cor Description

S1 yellow turn-on when the sensor 1 is activated

S2 yellow turn-on when the sensor 2 is activated

PW green see led conditions table

FAULT red see led conditions table

CM 1 yellow turn-on when the mechanical contact 1 is activated

CM 2 yellow turn-on when the mechanical contact 2 is activated

SOL 1 yellow turn-on when the output to solenoid #1 is activated

SOL 2 yellow turn-on when the output to solenoid #2 is activated

Led Conditions

PW Led Fault Led Description

on off normal operation

on on

without data exchange:- master in stop mode - slave doesn´t exist on the project slave list- slave with wrong IO / ID - active reset on slave

blinking on without data exchange: slave with 0 adress

blinking blinkingperifherical fault: short or open sol 1 or sol 2

alternating blinking green and red leds

NTERFACE

MADE IN BRAZIL

PWRFAULTSENSOR2 1

SENSOR 2

SENSOR 1

ON BOARDSENSOR

Sensores e Instrumentoswww.sense.com.br

ASI3.2-SV-2EH-2EC-2ST

VALVE MONITOR2 HALL SENSOR

2 MECHANICAL CONTACT2 TRANSISTOR OUTPUTI/O=7h / ID=Ah / ID2=Eh

+-- -- +

YE

RD

YE

RD

TRANSISTOROUTPUTI<100mA

EXT. SOLENOID 2 1

MECHANICAL CONTACT

2 1

NO

NO

C C

AS

I+

AS

I-

BN

BU

IN ASI

2 1

OUTPUT

14

Page 16: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

Technical Specifications

Model A D and P

Number of wires 2 5

Input connection /output

2.5mm2 screwed terminals

Derivation 10 cm pigtail

2-wire,0.25mm2

10 cm pigtail 5wire, 0.25m2

Switching by cover yes yes

Internal Derivation SystemThis exclusive network cable derivation system totally integrated to the monitor allows to substitute the electronic board or thesolenoid valve without powering off the rest of the network.

Topology

Exclusive]Hot Swapping Network Module

The only product for valve monitoring that allows toexchange the network electronic module withoutinterrupting the rest of the network, in hazardous areasZone 1.

]Solenoid Exchange

The same way the solenoid coil can be substituted without powering off the network, also in Zone 1.

Working Principle Sense internal derivator has screwed terminals withincreased security for connecting the network cable. Thecable enter and leave of the monitor through the cableglands. When the cable is accomodated no risk ofsparking is possible even in confined enclosure.

The network derivation is destined to the coupling of the electronic module that only will be energized when themonitor cover is completely closed.

In the encapsulated derivator there are sensibleelements to the magnet installed in the monitor cover.The network derivation is energized when the cover isinstalled.

Intrinsic Security Equivalent Technology

Due to the exclusive derivation system the SV monitor incorporates facilities of maintenance even energized that only the IntrinsicSecurity could provide.

The Security Increased Technology is applied in SV monitors allowing its maintenance in POTENTIALLY EXPLOSIVEATMOSPHERES classified as ZONA 1 with the smart solution allowing maintenance without shut dow the network.

15

Page 17: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

Electrical Connection

In the sensor signaling or network signalingmodel the wires can directly be connected inthe monitoring module that has pressureterminals for an easy connection.

The modules are installed inside of themonitor enclosure protected against theliquids penetration by a rubber ring.

Cable InputThe monitors had been projected to receive directly flexible conduits or cable gland through screwed inputs. They are equippedwith 1/2" NPT, 3/4" NPT, PG13.5, PG16 or M20 screwed female inputs.

Flexible Flexible Conduit Rigid Conduit Cable Gland

Number of inputsOptionally the monitor can be supplied with one, two or three additional inputs with or without cable gland for the solenoidconnection with external coil and remote input or it still can be equipped with M12 connector .

Stantard - 2 holes 1 extra hole 2 extra holes 3 extra holes

M12 Connector

Enclosure Specifications

Enclosure Material aluminium

Cable input 2 3/4" NPT threaded holes (standard)

Additional cable input up to 3 PG9 entrance

Cover screws 7 screws of stainless steel 304

Cover sealing rubber o´ring

Operation temperature 0ºC to + 55ºC

Protection class IP 66

Weight 1.6Kg

17

Page 18: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

Solenoid ValvesLooking for completing the valve automation line, the monitors can be supplied with solenoid valves. The monitor set is suppliedtotally mounted. The valve is fixed mechanically on the monitor and also integrate electrical connection. Available in severalversions is included for hazardous areas (certified by Cepel/Inmetro) becoming the system more safe, practical and versatile.

Internal Coil

Sense valve monitor allows the internal mounting of the solenoid coil. It´s fixed mechanically trought of two supports especiallydeveloped, one for the coil and other for the valve body. For each manufacturer and valve model exist a different support.

Internal coil detail Valve mounted

18

Support mounting for solenoid fixing

Solenoid Coil

Valve body

the valve body

Bracket for mounting of

and solenoid set

Adapter and support for coil

Page 19: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

Valve Options

19

Sense Model

Model VS

Housing material aluminium or stainless steel

Number of ways 5 / 2 ways

Connectionspressure input (P) 1/4" BSPoutput(A and B) 1/4" BSPescape (EA and EB) 1/8" BSP

Pressure range 2 to 7 bar

7 bar outflow 1450 l / min

Cv 0.9

Operation temperature 0ºC to 50ºC max.Valve

Solenoid

Sense Coil Options

Sense Coil

GeneralPurpose

Increased Safe Intrinsec Safe

Model BS BS-Exm BS-Exia

Power Supply 24 Vdc 24 Vdc 24Vdc

Permissible variation ±10% ±10% ±10%

Dissiped power < 0.5W < 0.5W < 0.5W

Started current 35 mA 35 mA 35 mA

Permanent current 20 mA 20 mA 20 mA

State indicator no no no

Ex Protection - Ex m Ex ia

Marking - BR Ex m BR-Ex ia IIC T6 IP66

Page 20: Monitor SV Brochure Rev E · Internal sensors 2 NPN 2 PNP 2 Reed 2 Namur Activated sensor magnetic magnetic magnetic magnetic Signaling led yellow led yellow - - Angle/ Histeresys

www.sense.com.brOur addresses:

Head Office - SENSE - São Paulo

Rua Tuiuti, 1237 – Tatuapé

São Paulo – SP - Brazil

03081-000

Phone: +55 11 2145-0444

[email protected]

Factory - SENSE - Minas Gerais

Av. Joaquim Moreira Carneiro, 600 – Santana

Santa Rita do Sapuací – MG - Brazil

37540-000

Phone: +55 35 3471- 2555

Fax: +55 35 3471-2033

We rerserve all the rights of modify the information showed here without prior warningRev.E 09/17