monthly provisional values from ucte database as of 13 … · 2020. 4. 10. · july 2006 ucte july...

20
Monthly provisional values union for the co-ordination of transmission of electricity July 2006

Upload: others

Post on 04-Feb-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • Monthly provisional valuesunion for the co-ordination of transmission of electricity

    July 2006

  • July 2006

    UCTE July 2006

    Table of contents Page

    1 Electricity supply situation of the countries 2

    2 Physical energy flows 3

    3 Monthly consumption 4

    4 Monthly consumption variation 6

    5 Consumption of the last 12 months 8

    6 Variation of the last 12 months’ consumption 10

    7 Load flows (night) 12

    8 Load flows (day) 13

    9 Unavailability of international tie lines ( major events ) 14

    10 Network reliability ( major events ) 16

    11 Scheduled exchanges 17

    12 Load on the 3rd Wednesday 18

    General remarks and abbreviations used in the tables

    - All values of production and consumption in chapter 1, 3&4, 5&6 and 12 are calculated to represent100% of the national values.

    - DK_W Denmark West represents the Western part of Denmark synchronously interconnected withUCTE (Jutland and Funen).

    - UA_W Ukraine West represents the so-called Burshtyn Island synchronously interconnected withUCTE.

    - CET Central European Time

    - The Bulgarian values of production and consumption are gross values.

    Monthly provisional values from UCTE database as of 13 November 2006

  • July 2006

    UCTE July 2006

    1 Including deliveries from industry2 The reported figures are best estimates based on actual measurements and extrapolations.3 Data on hydro, other renewable, not clearly identifiable production are not yet available.

    All representativities of the national production and consumption values used to calculate values at a representativity of100% as stated in the table above

    1 Electricity supply situation of the countries

    2

    Countries AT BA BE BG CH CS CZ DE ES FR GR HR HU IT LU MK NL PL PT RO SI SK DK_W

    UA_W

    ProductionTherm.nuclear 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100Thermal conv. 100 100 100 100 100 100 100 100 97 100 100 100 100 100 100 100 100 100 94 100 100 100 100 100

    Hydro prod 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100Other renew. 100 100 100 100 100 100 100 100 95 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100Not identify 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100

    Consumption 100 100 100 100 100 100 100 100 98 100 100 100 100 100 100 100 100 100 96 100 95 100 100 100

    Consumption in GWhbalance

    Coun- Therm. Therm Hydro Other Of Not var. var.tries nuclear conv. prod renew. w hich iden- Total monthly [%]

    wind tify

    AT 0 1519 3676 0 0 602 5797 1 -229 295 5273 4,1 66107 3,6BA 0 694 367 0 0 0 1061 -208 0 853 1,4 11188 1,3BE 3338 2794 116 169 14 0 6417 1 603 141 6879 6,8 89430 2,1BG 1207 1569 305 0 0 0 3081 -623 34 2424 -8,6 36671 3,7CH 2073 182 3923 84 0 0 6262 1 -1165 379 4718 0,3 63495 2,5CS 0 2088 974 0 0 0 3062 1 -112 29 2921 4,0 42360 2,5CZ 1780 3840 304 9 2 0 5933 1 -1299 84 4550 4,4 64269 3,6DE 12731 28469 1981 1990 929 0 45171 1 577 688 45060 2,9 558513 0,4ES 4798 15636 1847 1652 1143 0 23933 1 -365 548 23589 6,6 256753 4,8FR 32900 2815 4368 327 94 0 40410 -4945 559 34906 0,3 484510 0,8GR 0 3969 413 175 168 0 4557 1 504 40 5021 -4,3 53394 2,2HR 0 553 364 1 0 0 918 1 520 15 1423 7,5 16969 4,4HU 1248 1619 0 0 0 0 2867 1 503 0 3370 6,1 40312 4,0IT 0 22854 4660 609 183 0 28123 1 3848 732 31239 4,1 333600 1,3LU 0 251 69 7 3 0 327 326 96 557 5,3 6558 6,3MK 0 391 121 0 0 0 512 1 65 0 577 0,7 8337 7,1NL 313 6436 0 479 82 0 7228 1 1892 0 9120 -0,6 115821 2,6PL 0 10910 157 17 9 0 11084 1 -458 66 10560 7,4 134802 4,0PT 0 2878 527 347 176 0 3752 1 533 96 4372 4,4 50752 3,4RO 479 2245 1710 0 0 0 4434 1 -228 18 4188 7,3 52239 1,0SI 491 424 260 0 0 0 1175 -58 0 1117 5,9 13057 0,0SK 1254 395 349 0 0 191 2189 1 -90 17 2082 8,3 26960 2,8

    UCTE 62612 112531 26491 5866 2803 793 208293 1 -409 3837 204799 3,2 2526097 1,9DK_W 0 1387 1 273 156 0 1661 1 -43 0 1618 3,9 21683 2,1UA_W 0 568 8 0 0 0 576 1 -255 0 321 13,0 4369 -1,6

    in GWh [%]in GWh

    Exchange Net production in GWh

    last 12 months

    Pump

    2

    3

  • July 2006

    UCTE July 2006

    These physical energy flows were measured on the cross-frontier transmission lines (< 110 kV) listed in table 9 of the Statistical Yearbook.These values may differ from the official statistics and the exchange balances in chapter 1.

    1 Other III: Albania, Belarus, Denmark East, Great Britain, Morocco, Republic of Moldavia, Norway, Sweden, Republic of Turkey and Ukraina

    Total physical energy flows =Sum of physical energy flows between UCTE countries =

    2 Physical energy flows

    3

    GWhValues in

    BEDE

    PL

    CS

    GR

    FR

    ESPT

    SK

    BA

    NL

    HU

    CZ

    CH

    AT

    SI

    LU

    HR

    MK

    IT

    Associate member(synchronous with UCTE region)

    Synchronous operationwith UCTE region

    UA_W

    RO

    BG

    NO

    SE

    RU

    LT

    BY

    MD

    TR

    AL

    GB

    DK_W

    IRL

    MAMA DZ TN

    DK_E

    UA

    254 →→←← 775

    ←←

    103

    3 →

    163 →

    →→

    →→

    ←←

    ← 7

    2

    1249 →← 54

    ←← 271

    1258 →← 44

    ← 226

    179 →

    801 →←

    137

    ← 44067 →

    ←←← 90

    153 →← 102

    ← 82352

    0 →

    →37 →

    ← 1

    31139 →

    25 →94 →

    ← 230

    ←← 88

    55 →→

    ←←

    181408 →

    ← 39

    ← 444 ← 3

    65

    ← 6

    9

    ← 182

    ←←

    178

    ←← 38

    10 →

    ← 511 108 →← 73

    ← 158

    ← 3

    92

    84 →

    ← 75

    ←←← 7

    181 →→

    ← 8

    5

    ← 19

    7

    ←← 52

    1272

    →→

    ← 42

    7

    525 →→

    ← 1178

    898 →

    ← 493

    ← 12

    ←← 1090

    ← 5

    86

    ← 3

    92

    10 →←

    ← 5

    58

    ← 1

    06

    ←←

    247

    194

    →→

    ←←

    ← 1

    6617

    6→→

    1 →→

    ←←

    159

    ←←

    211

    8

    35 →

    ←← 137

    13 →

    136→

    →→

    4→→

    29 →

    ←← 69

    28 →

    1 →

    14 →→

    ←←

    ← 5

    1

    ←←

    ← 1

    87→

    →→

    4 →

    ←← 27

    ←← 361

    1 →

    ←←

    698

    ←← 74

    176→

    →→

    87 →→

    741

    →→

    19→

    →→→

    →→

    →←

    ←←

    ←←

    ←←

    ←←←←

    22818GWh 26029GWh

    Im porting countr ie sExpor ting countr ie s

    A T BA BE BG CH CS CZ DE ES FR GR HR HU IT LU MK NL PL PT RO SI SKDK_W

    UA _W

    Other III1

    A T - - - - 511 - 4 823 - - - - 37 131 - - - - - - 108 - - - - 1614BA - - - - - 94 - - - - - 361 - - - - - - - - - - - - - 455BE - - - - - - - - - 52 - - - - 179 - 801 - - - - - - - - 1032BG - - - - - 158 - - - - 392 - - - - 69 - - - 84 - - - - 0 703CH 28 - - - - - - 520 - 271 - - - 2118 - - - - - - - - - - - 2937CS - 230 - 0 - - - - - - - 182 13 - - 178 - - - 1 - - - - 38 642CZ 392 - - - - - - 1090 - - - - - - - - - 10 - - - 408 - - - 1900DE 898 - - - 698 - 1 - - 44 - - - - 440 - 1178 153 - - - - 194 - 312 3918ES - - - - - - - - - 163 - - - - - - - - 775 - - - - - 103 1041FR - - 1272 - 525 - - 1258 427 - - - - 1249 - - - - - - - - - - 741 5472GR - - - 0 - - - - - - - - - 7 - 0 - - - - - - - - 75 82HR - 25 - - - 0 - - - - - - 0 - - - - - - - 493 - - - - 518HU 12 - - - - 69 - - - - - 365 - - - - - - - 0 - 0 - 4 - 450IT 0 - - - 29 - - - - 54 14 - - - - - - - - - 1 - - - - 98LU - - 226 - - - - 67 - - - - - - - - - - - - - - - - - 293MK - - - 0 - 0 - - - - 181 - - - - - - - - - - - - - - 181NL - - 137 - - - - 35 - - - - - - - - - - - - - - - - - 172PL - - - - - - 558 102 - - - - - - - - - - - - - 159 - - 19 838PT - - - - - - - - 254 - - - - - - - - - - - - - - - - 254RO - - - 85 - 197 - - - - - - 137 - - - - - - - - - - 0 0 419SI 73 - - - - - - - - - - 139 - 444 - - - - - - - - - - - 656SK - - - - - - 39 - - - - - 586 - - - - 4 - - - - - 55 - 684DK_W - - - - - - - 247 - - - - - - - - - - - - - - - - 225 472UA _W - - - - - - - - - - - - 181 - - - - - - 106 - 27 - - - 314Other III1 - - - 0 - 10 - 353 3 72 0 - - - - - - 213 - 0 - - 233 - - 884 Sum im p 1403 255 1635 85 1763 528 602 4495 684 656 587 1047 954 3949 619 247 1979 380 775 191 602 594 427 59 1513 26029

    Sum e xport

    138→

    →→

    →→→→

    ←←

    ←←

    ←←

    143

    4 →

  • July 2006

    UCTE July 2006

    3 Monthly consumption

    4

    TWh

    I II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII2005 2006

    60TWh

    30

    0I II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII

    2005 2006

    TWh

    I II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII2005 2006

    200

    150

    250

    CH

    AT

    NL

    BE

    PT

    DE

    FRIT

    ESPL

    UCTE

    6,0

    3,0

    12,0

    9,0

  • July 2006

    UCTE July 2006

    3 Monthly consumption

    5

    TWh

    I II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII2005 2006

    TWh

    I II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII2005 2006

    TWh

    I II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII

    2005 2006

    7,5

    BA

    HR

    MK

    UA_W

    DK_W

    BG

    SK

    SI

    CS

    LU

    1,1

    0

    2,2

    CZ

    RO

    GR

    HU

    5,0

    2,5

    1,0

    2,0

    3,0

    4,0

    5,0

    0

  • July 2006

    UCTE July 2006

    Monthly consumption variation4

    6

    2005 2006 Values in %

    10UC 0TE -10

    I II III IV V VI VII VIII IX X XI XII

    20 10

    0 0

    AT -20 -10 CZI II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII

    20 10

    0 0

    BA -20 -10 DEI II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII

    10 15

    0 0

    BE -10 -15 ESI II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII

    15 10

    0 0

    BG -15 -10 FRI II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII

    30 10

    00

    CH -10 -10 GRI II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII

    15 10

    0 0

    CS -15 -10 HRI II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII

  • July 2006

    UCTE July 2006

    Monthly consumption variation4

    7

    2005 2006 Values in %

    10

    0

    HU -10 PTI II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII

    10

    0 0

    IT -10 ROI II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII

    10

    0

    LU -20 SII II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII

    10

    0

    MK -10 SKI II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII

    20

    0

    NL -10 DK_WI II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII

    20

    0

    PL -20 UA_WI II III IV V VI VII VIII IX X XI XII I II III IV V VI VII VIII IX X XI XII

    0

    10

    -10

    10

    -10

    0

    20

    -20

    0

    20

    -10

    0

    10

    -10

    0

    10

    -10

  • July 2006

    UCTE July 2006

    Consumption of the last 12 months5

    8

    TWh

    1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11

    2001 2002 2003 2004 2005 2006

    1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11

    2001 2002 2003 2004 2005 2006

    1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11

    2001 2002 2003 2004 2005 2006

    1800

    2600

    UCTE

    0

    300

    600DE

    FRIT

    ES

    PL

    CH

    30

    60

    90

    120

    BE

    HU

    AT

    GR

    NL

  • July 2006

    UCTE July 2006 9

    Consumption of the last 12 months5TWh

    1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11

    2001 2002 2003 2004 2005 2006

    1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11

    2001 2002 2003 2004 2005 2006

    1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11 1 3 5 7 9 11

    2001 2002 2003 2004 2005 2006

    10

    40

    70CZ

    HR

    SK

    PT

    0

    20

    40

    60RO

    CS

    SI

    BG

    LU

    DK_W

    0

    7

    14

    MK

    BA

    UA_W

  • July 2006

    UCTE July 2006

    Variation of the last 12 months´consumption in %6

    10

    UCTE2001 2002 2003 2004 2005 2006

    AT CZ2001 2002 2003 2004 2005 2006 2001 2002 2003 2004 2005 2006

    BA DE2001 2002 2003 2004 2005 2006 2001 2002 2003 2004 2005 2006

    BE ES2001 2002 2003 2004 2005 2006 2001 2002 2003 2004 2005 2006

    BG FR2001 2002 2003 2004 2005 2006 2001 2002 2003 2004 2005 2006

    CH GR2001 2002 2003 2004 2005 2006 2001 2002 2003 2004 2005 2006

    CS HR2001 2002 2003 2004 2005 2006 2001 2002 2003 2004 2005 2006

    -5

    0

    5

    10

    -5

    0

    5

    10

    -10

    -5

    0

    5

    -5

    0

    5

    10

    -5

    0

    5

    10

    -5

    0

    5

    10

    -15

    0

    15

    -20

    -10

    0

    10

    -5

    0

    5

    10

    -5

    0

    5

    10

    -5

    0

    5

    10

    -5

    0

    5

    10

    -5

    0

    5

    10

  • July 2006

    UCTE July 2006 11

    Variation of the last 12 months´consumption in %6

    HU PT2001 2002 2003 2004 2005 2006 2001 2002 2003 2004 2005 2006

    IT RO2001 2002 2003 2004 2005 2006 2001 2002 2003 2004 2005 2006

    LU SI2001 2002 2003 2004 2005 2006 2001 2002 2003 2004 2005 2006

    MK SK2001 2002 2003 2004 2005 2006 2001 2002 2003 2004 2005 2006

    NL DK_W2001 2002 2003 2004 2005 2006 2001 2002 2003 2004 2005 2006

    PL UA_W2001 2002 2003 2004 2005 2006 2001 2002 2003 2004 2005 2006

    -5

    0

    5

    10

    -5

    0

    5

    10

    -5

    0

    5

    10

    -505

    1015

    -5

    0

    5

    10

    -5

    0

    5

    10

    -505

    1015

    -5

    0

    5

    10

    -10

    -5

    0

    5

    -5

    0

    5

    10

    -5

    0

    5

    10

    -5

    0

    5

    10

  • ATC

    H

    ES

    IT

    FR

    SIB

    AC

    S

    HU

    CZ

    SK

    LU

    BE

    NL

    GB

    DK

    _W

    DE

    PL

    SE

    RU

    SLT BY

    UA

    _W

    AL

    GR

    BG

    RO

    PT MA

    HR

    MK

    MD

    TR

    I = Import balanceE = Export balance

    MA

    Associate member

    Synchronous operation with UCTE region

    NO

    DK_E

    UA

    Sum of load flows in MW:UCTE = 27811 MW Total =

    July 20067

    12 UCTE July 2006

    Load flows (night) on 19.07.06 at 03:00 a.m. CET in MW

    30783 MW

    E =

    299

    E =

    296

    910

    501

    181

    66

    64 407

    225

    280

    106 452

    99

    121

    349

    39

    2387

    105

    364

    283

    244

    4851404

    562

    1

    2303

    903

    1304

    1024

    26

    183

    1481

    1209

    926

    1234

    1529

    87

    604

    109

    648

    46349

    324

    102

    721

    299

    263 232

    1

    22

    907

    136

    E =

    145

    I = 8

    4

    E =

    123

    E =

    1772

    E =

    3023

    E =

    803

    I = 1

    393

    E =

    79

    I = 3

    56

    I = 9

    55

    E =

    4111

    E =

    1903

    I = 1

    481

    I = 2

    001

    E =

    24I =

    429

    8

    I = 4

    21

    I = 7

    08

    I = 7

    51

    E =

    338

    E =

    706

    E =

    24

    254238

    209

    92

    538

    45

    799

    12

    26

    28

    56

    62

    168

    28716

    475

    91226

    7

    379

    15

  • ATC

    H

    ES

    IT

    FR

    SIB

    AC

    S

    HU

    CZ

    SK

    LU

    BE

    NL

    GB

    DK

    _W

    DE

    PL

    SE

    RU

    SLT BY

    UA

    _W

    AL

    GR

    BG

    RO

    PT MA

    HR

    MK

    MD

    TR

    I = Import balanceE = Export balance

    MA

    Associate member

    Synchronous operation with UCTE region

    NO

    DK_E

    UA

    Sum of load flows in MW:UCTE =Total = 35620 MW

    July 20068

    13UCTE July 2006

    Load flows (day) on 19.07.06 at 11:00 a.m. CET in MW

    30712 MW

    E =

    2379

    E =

    196

    I = 1

    112

    E =

    843

    E =

    3820

    E =

    235

    E =

    1918

    I = 3

    859

    E =

    537E

    = 1

    122

    I = 7

    45

    I = 7

    34

    I = 8

    05

    I = 3

    094

    I = 4

    19

    I = 3

    1

    I = 2

    430

    E =

    577

    I = 2

    72

    E =

    149

    I = 1

    85

    E =

    85

    E =

    351

    31

    848

    2113

    174

    188

    108

    451

    106

    209

    538

    406 524

    121

    2016

    1960

    310

    291

    225

    1631899

    678

    787

    616

    63157

    3

    2375

    2

    57339

    767

    1152

    198

    717

    338

    629

    56

    53

    364

    88

    3303

    3277

    483

    494

    784

    200

    495

    27284

    216

    200

    262

    624

    74464

    119

    32

    95 E =

    386

    1197

    83

    48

    38

    45

    205

    9

    603

    218

    795

    548

    20520

    3

    1711

    581

    51

  • 0,5 mm 2,0 mm 2,5 mm1,5 mm1,0 mm

    20.02.01 08:21 AM21.02.01 08:29 AM22.02.01 10:03 AM23.02.01 08:27 AM

    UCTE July 2006UCTE July 20061414

    Unavailability of international tie lines( major events with sum over 740 minutes ) 9 9 July 2006

    Reasons :

    DK_W

    ES

    PT

    MA

    FR

    GB

    BE LU

    NL

    DE

    CH

    NO Ensted

    S.Fiorano

    124

    Serra

    Gorlago

    Winkeln

    Y-Rehag

    Balboa

    Alqueva

    01.06.06 00:00 AM R6

    164.1.1NO / Kristiansand - DK_W / Tjele 350 MVA

    43200 min

    13.07.06 06:50 AM R117.07.06 07:04 AM R1

    102.2.1DE / Kühmoos - CH / Laufenburg 220 kV / 469 MVA

    4151 min

    17.07.06 06:11 AM R1

    121.1.1CH / All'Acqua - IT / Ponte 220 kV / 278 MVA

    741min

    Mastaing

    R1 - MaintenanceR2 - RepairR3 - New constructions R4 - Overload (also calculated break)R5 - False operation R6 - Failure in prodection device or other element R7 - Outside impacts (animals, trees, fire, avalanches, ...)R8 - Very exceptional conditions (weather, natural disaster, ...) R9 - Other reasonsR10 - Unknown reasons

    Kristiansand Tjele

    13.07.06 06:49 AM R117.07.06 07:04 AM R118.07.06 07:11 AM R119.07.06 06:53 AM R1

    102.3.1DE / Kühmoos - CH / Laufenburg 220 kV / 469 MVA

    2665 min

    01.07.06 00:00 AM R124.07.06 06:46 AM R1

    81.2.1FR / Sierentz - CH / Laufenburg 380 kV / 1167 MVA

    6062 min

    03.07.06 06:12 AM R104.07.06 08:08 AM R105.07.06 06:10 AM R1

    11.1.2NL / Meeden - DE / Diele 380 kV / 1382 MVA

    1572 min

    All’Acqua

    24.07.06 07:06 AM R1

    102.5.1DE / Tiengen - CH / Laufenburg 380 kV / 1131MVA

    11094 min

    17.07.06 14:00 PM R1

    104.1.1DE / Kühmoos - CH / Asphard 380 kV / 1340 MVA

    3610 min

    01.07.06 00:00 AM R1

    82.1.2FR / Bois-Tollot - CH / Chamoson 380 kV / 1409 MVA

    23930 min

    17.07.06 06:10 AM R118.07.06 06:23 AM R119.07.06 06:20 AM R120.07.06 06:19 AM R121.07.06 06:16 AM R124.07.06 06:12 AM R125.07.06 06:15 AM R126.07.06 06:15 AM R127.07.06 06:49 AM R131.07.06 06:11 AM R1

    11.1.1NL / Meeden - DE / Diele 380 kV / 1382 MVA

    6581 min

    Diele

    01.07.06 07:07 AM R1

    71.1.2FR / Vigy - DE / Uchtelfangen 380 kV / 1790MVA

    40967 min

    03.07.06 07:28 AM R1

    71.2.1FR / St-Avold - DE / Ensdorf 220 kV / 261MVA

    6466 min

    03.07.06 07:13 AM R104.07.06 07:03 AM R105.07.06 07:58 AM R106.07.06 07:37 AM R107.07.06 07:31 AM R1

    192.1.1LU / Heisdorf - DE / Trier 220 kV / 490 MVA

    2309 min

    01.07.06 07:19 AM R102.07.06 07:26 AM R1

    192.2.1LU / Heisdorf - DE / Quint 220 kV / 490 MVA

    1181 min

    06.07.06 08:39 AM R1

    141.1.1CH / Y-Rehag - AT / Meiningen 220 kV / 501MVA

    1664 min

    03.07.06 07:30 AM R104.07.06 07:22 AM R105.07.06 07:30 AM R1

    41.3.1BE / Aubange - LU / Belval 150 kV / 157MVA

    1463 min

    17.07.06 07:09 AM R9

    83.1.1FR / Sierentz - CH/DE Asphard 380 kV / 1167 MVA

    4819 min

  • 0,5 mm 2,0 mm 2,5 mm1,5 mm1,0 mm

    20.02.01 08:21 AM21.02.01 08:29 AM22.02.01 10:03 AM23.02.01 08:27 AM

    Unavailability of international tie lines( major events with sum over 740 minutes ) 9 9 July 2006

    UCTE July 2005UCTE July 2005 1515

    Reasons : R1 - MaintenanceR2 - RepairR3 - New constructions R4 - Overload (also calculated break)R5 - False operation R6 - Failure in prodection device or other element R7 side impacts animals, trees, fire, avalanches, ...)-

    -Out (

    R8 Very exceptional conditions (weather, natural disaster, ...) R9 - Other reasonsR10 - Unknown reasons

    DE

    BY

    SK

    HU

    RO

    HRSI

    AT

    AL GR

    SE

    IT

    MK

    BG

    01.07.06 00:00 AM R10

    391.1.1 CS/Kosovo A - MK/Skopje1 220 kV / 311 MVA

    44600 min

    CS

    711

    420

    PL

    460

    DK_W

    450

    UA_W

    BA

    700700410430

    710

    01.07.06 07:43 AM R1012.07.06 07:24 AM R1013.07.06 06:36 AM R10

    111.3.1 DE / Dellmensingen - AT / Bürs 220 kV / 492 MVA

    926 min

    CZ

    730

    07.07.06 10:01 AM R112.07.06 06:59 AM R913.07.06 07:24 AM R9

    117.1.2 DE / Oberbrunn - AT / Silz 220 kV / 793 MVA

    1323 min

    01.07.06 00:00 AM R10

    391.2.1 CS/Kosovo A - MK/Skopje1 220 kV / 311 MVA

    44600 min

    UA

    Kozlodui

    Tantareni

    277

    06.06.06 00:10 AM R208.06.06 07:10 AM R221.06.06 07:05 AM R6

    165.1.1 SE / Stenkullen - DK_W / V. Hassing 125 MVA

    1152 min

    Vester Hassing Stenkullen

    165

    Galatina

    Arachthos

    205IT

    17.07.06 07:01 AM R119.07.06 07:05 AM R1

    02.07.06 01:20 PM R511.07.06 05:29 PM R513.07.06 02:12 PM R5

    27.07.06 05:24 PM R527.07.06 06:20 PM R5

    381.2.1 BA / Trebinje - CS / Perucica 220 kV / 276 MVA

    2467 min

    24.07.06 08:35 AM R125.07.06 07:29 AM R126.07.06 08:25 AM R129.07.06 07:27 AM R1

    381.1.1 BA / Trebinje - CS / Podgorica 380 kV / 1264 MVA

    2240 min

    15.07.06 07:06 AM R125.07.06 06:53 PM R1

    11.07.06 05:55 PM R513.07.06 03:42 PM R5

    381.3.1 BA / Trebinje - CS / Herceg Novi 110 kV / 90 MVA

    1814 min

    06.07.06 10:15 AM R107.07.06 09:03 AM R210.07.06 07:00 AM R911.07.06 06:51 AM R919.07.06 04:37 PM R10

    117.1.1 DE / Oberbrunn - AT / Silz 220 kV / 793 MVA

    1431 min

  • July 2006

    UCTE July 2006

    1 ( year [in min] * energy not supply ) / consumption last 12 months

    Reasons:R4 Overload (also calculated break) R8 Very exceptional conditionsR5 False operation (weather, natural disaster, ...)R6 Failure in protection device or other element R9 Other reasonsR7 Outside impacts (animals, trees, fire, avalanches, ...) R10 Unknown reasons

    (animals, trees, fire, avalanches, ...)

    Network reliability ( major events )10

    16

    BEDE

    PL

    CS

    GR

    FR

    ESPT

    SK

    BA

    NL

    HU

    CZ

    CH

    AT

    SI

    LU

    HR

    MK

    IT

    RO

    BG

    DK_W

    UA_W

    No Country Substation Reason Energy not supplied Total loss of power Restoration Equivalent time [ MWh ] [ MW ] time [ min ] of interruption1

    1 CZ Cechy Stred R4 3350 3000 242 27,40

    2 IT Priolo Gargallo R8 784 244 184 1,24

    3 CZ Krasikov R9 22 0 17 0,18

    4 DE Gersteinw erk R8 187 350 32 0,18

    5 CZ Krasikov R6 19 0 16 0,16

    6 DE Gersteinw erk R8 160 300 32 0,15

    7 CZ Sokolnice R6 11 28 5 0,09

    8 ES Sabon R6 44 155 17 0,09

    9 IT Villavalle R5 43 124 21 0,07

    10 IT Nocera R9 39 15 156 0,06

    11 ES Castellbisbal R6 26 198 8 0,05

    12 ES Fuencarral R6 6 29 7 0,01

    13 FR Plaisance R8 7 29 15 0,01

    2

    14 635

    7

    8

    9

    10

    1112

    13

  • July 2006

    UCTE July 2006

    - Control areas can differ from national borders ( i.e. German block which includes parts of AT, LU and DK ).

    - Values are calculated on an hourly base ( MWh ).

    - This values are not the provisional values entered in the VULCANUS system, but the definitive values afteran eventual correction during the actual date.

    - Export Programs: Sum of all positive values of every hour of every border- Import Programs: Sum of all negative values of every hour of every border

    - Export Programs at 03:00: Sum of all positive values the third Wednesday from 02:00 to 03:00 a.m.- Import Programs at 03:00: Sum of all negative values the third Wednesday from 02:00 to 03:00 a.m.

    - Export Programs at 11:00: Sum of all positive values the third Wednesday from 10:00 to 11:00 a.m.- Import Programs at 11:00: Sum of all negative values the third Wednesday from 10:00 to 11:00 a.m.

    17

    11 Scheduled exchanges in MWhControl Export Import Export Import Export Import

    area Programs Programs Programs Programs Programs Programsat 03:00 at 03:00 at 11:00 at 11:00

    AT 799739 764267 1903 823 219 1483BA 291452 86122 196 136 259 75BE 606851 1163208 928 1223 635 1574BG n.a. n.a. n.a. n.a. n.a. n.a.CH 2807654 1640714 2660 2671 4499 690CS 416429 301951 610 287 648 444CZ 1774035 441667 2533 718 2541 611DE 2193222 2869929 3416 2649 4476 5851ES 990329 615641 2204 310 1367 807FR 7148974 2347314 7409 3300 8365 7258GR 7805 513307 0 716 0 762HR 131525 653513 113 815 176 934HU 406802 910465 506 968 476 1276IT 102639 3951017 125 4388 293 3386

    MK 91100 155700 165 109 197 225NL 305188 2154112 501 2499 479 2886PL 612429 148973 1000 130 1000 410PT 158356 686484 10 1510 448 748RO 331751 104032 256 128 550 151SI 583194 532081 712 802 770 593SK 500954 354159 602 390 619 697

    DK_W 447308 404069 657 287 700 773UA_W 249782 0 298 0 350 0

  • July 2006

    UCTE July 2006

    1 Variation as compared to corresponding month of theprevious year

    2 Power produced in parallel operation(including autoproduction)

    3 The reported figures are best estimates based on actualmeasurements and extrapolations.

    4 Average value of each hour

    Load on the 3rd Wednesday

    18

    12

    Highest Load ParallelloadMW var.%1 % MW

    AT 7728 5,0 100 10010BA 1444 1,1 100 1518BE 3 10801 10,8 100 9465BG 4328 2,3 100 4876CH 7904 1,0 100 12015CS 4908 5,2 100 4498CZ 7670 5,5 100 9656DE 72502 -3,3 91 71000ES 40279 2,9 98 37725FR 58229 2,6 100 58689GR 8152 -10,8 100 7305HR 2328 4,8 100 1583HU 5669 2,3 100 4691IT 53165 0,7 100 49072LU 865 -6,5 100 830MK 955 2,9 100 839NL 16566 17,9 100 13835PL 4 16877 8,5 100 20401PT 7546 0,8 96 6630RO 6426 6,4 100 6563SI 1932 4,5 95 1915SK 3430 8,4 100 3218

    UCTE 328383 2,3 336334DK_W 2616 4,8 100 2488UA_W 654 4,0 100 964

    pow er2representativity

    Consumption hourly load curves on 19.07.2006 Values in GW

    0

    20

    40

    60

    80

    DE

    FR

    ES

    PL

    IT

    3

    6

    9

    12

    15

    18

    NL BE

    CZ

    GR

    0

    3

    6

    9

    HU

    SK

    AT

    MK

    CH

    0

    2

    4

    6

    8

    SI

    PT

    LU

    BG

    DK_W

    0 2 4 6 8 10 12 14 16 18 20 22 h

    0 2 4 6 8 10 12 14 16 18 20 22 h

    0

    2

    4

    6

    8

    UA_W

    RO

    BA

    CS

    HR

    0 2 4 6 8 10 12 14 16 18 20 22 h

    0 2 4 6 8 10 12 14 16 18 20 22 h

    0 2 4 6 8 10 12 14 16 18 20 22 h

    0 2 4 6 8 10 12 14 16 18 20 22 h

    200

    250

    300

    350

    UCTE

  • ContactBoulevard Saint-Michel, 15B-1040 Brussels – BelgiumTel + 32 2 741 69 40 – Fax + 32 2 741 69 49

    info @ ucte.orgwww.ucte.org