Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January 15, 2004 10 CFR 50, Appendix E Section VI U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Monticello Nuclear Generating Plant Docket 50-263 License No. DPR-22 Emergency Response Data System (ERDS) - Revision to Previously Submitted Data Point Library Information Nuclear Management Company, LLC (NMC) is submitting a revised Data Point Library software specification for the Monticello Nuclear Generating Plant (MNGP) due to the revisions to the specification sheets listed below: 1. The minimum and maximum instrument range of PCT138 (NRC ERDS Parameter: DW ED SMP LV) has been revised to be 164 and 565 as indicated on sheet No. 17. 2. The minimum and maximum instrument range of PCT139 (NRC ERDS Parameter: DW FD SMP LV) has been revised to be 164 and 565 as indicated on sheet No. 18. 3. The minimum and maximum instrument range of D23C0310 (NRC ERDS Parameter: DW TEMP) has been modified to be 0 and 600 as identified on sheet No. 35. 4. The point ID of NRC ERDS Parameter "SP TEMP" was mistakenly typed as uD23C0410" in the ERDS Software Requirement Specification (ERDS-SRS-1-3). The corrected point ID of NRC ERDS Parameter "SP TEMP" should be uD23C0210'. Therefore, the point ID of NRC ERDS Parameter "SP TEMP" has been updated to be "D23C0210" as indicated on sheet No. 36. Also, the maximum instrument range of D23C021 0 (NRC ERDS Parameter: SP TEMP) has been revised to be 240 as indicated on the same page. 5. The maximum instrument range of CST100 and CST101 (NRC ERDS Parameters: CST LEVEL) has been revised to be 30 as indicated on sheet No. 42 and 43. 2807 West County Road 75 * Monticello, Minnesota 55362-9637 2C 0 Telephone: 763295.5151 * Fax: 763.295.1454 AO

Upload: others

Post on 26-Jun-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Monticello Nuclear Generating PlantCommnted to NudearE ce~ece Operated by Nuclear Management Company, LLC

L-MT-03-094January 15, 2004 10 CFR 50, Appendix E

Section VI

U.S. Nuclear Regulatory CommissionATTN: Document Control DeskWashington, DC 20555

Monticello Nuclear Generating PlantDocket 50-263License No. DPR-22

Emergency Response Data System (ERDS) - Revision to Previously Submitted DataPoint Library Information

Nuclear Management Company, LLC (NMC) is submitting a revised Data Point Librarysoftware specification for the Monticello Nuclear Generating Plant (MNGP) due to therevisions to the specification sheets listed below:

1. The minimum and maximum instrument range of PCT138 (NRC ERDSParameter: DW ED SMP LV) has been revised to be 164 and 565 as indicatedon sheet No. 17.

2. The minimum and maximum instrument range of PCT139 (NRC ERDSParameter: DW FD SMP LV) has been revised to be 164 and 565 as indicatedon sheet No. 18.

3. The minimum and maximum instrument range of D23C0310 (NRC ERDSParameter: DW TEMP) has been modified to be 0 and 600 as identified on sheetNo. 35.

4. The point ID of NRC ERDS Parameter "SP TEMP" was mistakenly typed asuD23C0410" in the ERDS Software Requirement Specification (ERDS-SRS-1-3).The corrected point ID of NRC ERDS Parameter "SP TEMP" should beuD23C0210'. Therefore, the point ID of NRC ERDS Parameter "SP TEMP" hasbeen updated to be "D23C0210" as indicated on sheet No. 36. Also, themaximum instrument range of D23C021 0 (NRC ERDS Parameter: SP TEMP)has been revised to be 240 as indicated on the same page.

5. The maximum instrument range of CST100 and CST101 (NRC ERDSParameters: CST LEVEL) has been revised to be 30 as indicated on sheet No.42 and 43.

2807 West County Road 75 * Monticello, Minnesota 55362-9637 2C 0Telephone: 763295.5151 * Fax: 763.295.1454 AO

Page 2: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

USNRCPage 2

6. The names and associated information of NMC personnel contact pages.(sheetNo. 56 and 57) have been revised to reflect the personnel changes in thedepartment of Computer & Information Systems.

7. The information about the computer hardware and operating system softwarehave been revised to reflect existing computer hardware and latest operatingsystem software on the host as indicated on sheet No. 59.

Due to a cognitive error, it was not recognized by station personnel that these changesneeded to be submitted to the NRC within 30 days of its completion. The issue hasbeen entered into the site's corrective action program for resolution.

This letter makes no new commitments.

Thomas J. PalmisanoSite Vice President, Monticello Nuclear Generating PlantNuclear Management Company, LLC

Enclosure

cc: Regional Administrator, Region Ill, USNRCProject Manager, Monticello, USNRCResident Inspector, Monticello, USNRCMinnesota Dept. of Commerce: wlo enclosure

Page 3: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Enclosure I

MONTICELLO NUCLEAR GENERATING PLANTProcess Computer System - Emergency Response Data System (ERDS) - Data

Point Library

61 pages follow

Page 4: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Generatina Plant Software Requirement Specification

Title: Number:

SRS Process CompUter System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

- . ~~~~~~~~~~~~~~~~~Sheet No: 1

Prepared By: /rAK A Effective Date: Fez . 4' o3

Reviewed By: 4 9 2r Approved By

I

LIST OF PAGES

SHEET

1

23456791011151718192329313334353637384243444852565759

DESCRIPTION

LIST OF PAGES

NI POWER RANGENI INTER RANGENI SOURC RNGREAC VES LEVRCS PRESSUREMAIN FD FLOWHPCI FLOWRCIC FLOWLPCI FLOWCR SPRAY FLDW ED SMP LVDW FD SMP LVEFF GAS RADEFF LIQ RADCOND AlE RADDW RADMN STEAM RADDW PRESSDW TEMPSPTEMPSP LEVELH2 CONCCST LEVELCST LEVELWIND SPEEDWIND DIRSTAB CLASSContactsContactsData Feeder Information

REVISION and DATE

Revision 3, 11/04/97

Revision 1,Revision 1,Revision 1,Revision 1,Revision 2,Revision 1,Revision 2,Revision 1,Revision 1,Revision 1,Revision 4,Revision 4,Revision 1,Revision 1,Revision 1,Revision 1,Revision 1,Revision 1,Revision 4,Revision 4,Revision 1,Revision 1,Revision 4,Revision 4,Revision 1,Revision 1,Revision 1,Revision 4,Revision 4,Revision 4,

4/14/924/14/924/14/924/14/921/1/934/14/921/1/934/14/924/14/924/14/9212/18/0312/18/034/14/924/14/924/14/924/14/924/14/924/14/9212/18/0312/18/034/14/924/14/9212/18/0312/18/034/14/924/14/924/14/9212/18/0312/18/0312/18/03

Page 5: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nudear Generating Plant Software Reaulrement Soedfication

SRSTitle:Process Computer System - Emergency Response DataSystem (ERDS) - Data Point Library

Number:ERDS-SRS-1-4

Sheet No: 2

I

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/DigitalEngr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trp Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92M01PCSNI POWER RNGC51C4001AVERAGE CONSISTENT APRM READINGNUCLEAR INSTRUMENTS, POWER RANGEA

N/A0125N/AN/AP12AVERAGE OF CONSISTENT APRMSAPRM UTILIZE 24 LPRMS LOCATED IN COREHI-HI TRIP=(.58W+62%),W=%RECIRC FLOWN/A

N/A

DOWNSCALE(3%), INOPBYPASSN/A

N/AThis point consists of either an average of all consistentAPRMs or an average of in-range APRMs if there are lessthan the required number of consistent signals.APRMS(Average Power Range Monitors) consist of anaverage of 24 LPRMs (Local Power Range Monitors). Eachindividual APRM signal will fail on Downscale(3%), Inop, orBypass. HI-HI trip feed RPS SCRAM for one-out-of-three-twice logic. HI trip (.58W+50%) results In Rod WithdrawBlock.

Page 6: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMnnfinalln Ni Adar flnprnfinn Pilnt lqnflwjnm R~ntflr~mPnt ~Rwtiflentinn

TIe: Number

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 3

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder.NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/DigitalEngr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:System.

01/07/92MO1PCSNI INTER RNG

(not available)NUCLEAR INSTRUMENTS, INTERMEDIATE RANGE

Not available to Process Computer

Page 7: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nudear Generafing Plant Software Requirement Spedfication

Te: Number:

SRS Process Computer.System - Emergency Response Data ERDS-SRS-14 4System (ERDS) - Data Point Library

Sheet No: 4

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/DigitalEngr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSNI SOURC RNG

(not available)NUCLEAR INSTRUMENTS, SOURCE RANGE

Not available to Process Computer System.

Page 8: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nudear Generating Plant Software Requirement Specification

Tide: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 6

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/DigitalEngr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/19/93MO1PCSRCS PRESSUREB21 C021 0RPV VALIDATED PRESSUREREACTOR COOLANT SYSTEM PRESSUREAPSIGN/A0.001500N/AN/AP3WEIGHTED AVERAGE OF CONSISTENT LEVELSPRESSURE SENSED OFF LEVEL REF LEGS1056 PSIG=SCRAMN/A

N/A

HI/LOW SENSORN/A

N/AThis point consists of either a weighted average of allconsistent pressure indicators or an average of in-rangepressure level indicators if there are less than the requirednumber of consistent signals.

Page 9: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyLiA-N-till M.A..~r flnarsinn Plnnt Qnh.A,nr& Pam. drommnt Cnopifi,'ain.*vflJ~uWlfl* l - lw.9llslt -.IUUS*

Tide: Number:SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4

System (ERDS) - Data Point LibrarySheet No: 7

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:GenericlCond Desc.:Analog/DigitalEngr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MOlPCSMAIN FD FLOWC51C9001SMOOTHED FEEDWATER FLOW LOOP AFEEDWATER FLOW INTO THE REACTOR SYSTEMAMLB/HRN/A04N/AN/AP4SMOOTHED FW FLOW CALC FROM A NOZZLE D/PFW NOZZLE IS DOWNSTREAM OF RX FW PUMPSN/ANIA

N/A

HI/LOW SENSORN/AN/AN/ASMOOTHED FW FLOW LOOP A is calculated usingFeedwater nozzle DIP, Pressure, and temperature. Smoothingalgorithm sums 1/12 current sample + 11/12 of previoussmoothed value. Sampling frequency is 5 seconds. Feedwaternozzles are located downstream of Reactor Feedwater Pumpsand ahead of high pressure heaters.

Page 10: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyUnnfirlln NMida~r (%anamflnnn P12nt Rnfhwmm R~n. iwrmPnt Rncwfin~finn mer

M~e: Number:SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4

System (ERDS) - Data Point LibrarySheet No: 8

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:AnalogbDigitalEngr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSMAIN FD FLOWC51C9002SMOOTHED FEEDWATER FLOW LOOP BFEEDWATER FLOW INTO THE REACTOR SYSTEMAMLB/HRN/A04N/AN/AP4SMOOTHED FW FLOW CALC FROM B NOZZLE D/PFW NOZZLE IS DOWNSTREAM OF RX FW PUMPSN/AN/A

N/A

HI/LOW SENSORN/ANIAN/ASMOOTHED FW FLOW LOOP B is calculated usingFeedwater nozzle D/P, Pressure, and temperature. Smoothingalgorithm sums 1/12 current sample + 11/12 of previoussmoothed value. Sampling frequency is 5 seconds. Feedwaternozzles are located downstream of Reactor Feedwater Pumpsand ahead of high pressure heaters.

Page 11: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonficello Nudear Generating Plant Software Reaulrement Soecificatlon

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 9

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder.NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/DigitalEngr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/19/93MO1PCSHPCI FLOWHPC100HPCI PUMP DISCHARGE FLOWHIGH PRESSURE COOLANT INJECTION FLOWAGPMN/A03500N/AN/AS1SIGNAL INPUT FROM FLOW TRANSMITTERFLOW ELEMENT ON HPCI PUMP DISHARGEN/AN/A

N/A

HIGH & LOW SENSORN/AN/AN/AHPCI is a steam turbine driven pump designed to deliver 2700gpm over reactor pressure range of 150-1120 psig. Flowelement is located on pump disharge line ahead of the testreturn line to the CST tanks and injection line into "B"feedwater line. HPCI injects into feedwater line prior to the lineentering containment.

Page 12: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northiem States Power CompanyMonti.ello Nudear Generatina Plant Software Requirement Specificadon

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1 -4System (ERDS) - Data Point Library

Sheet No: 10

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/DigitalEngr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MOIPCSRCIC FLOWRCI100RCIC PUMP DISCHARGE FLOWREACTOR CORE ISOLATION COOLINGAGPMN/A0500N/AN/AS1SIGNAL INPUT FROM FLOW TRANSMITTERFLOW ELEMENT ON RCIC PUMP DISHARGEN/AN/A

N/A

HIGH & LOW SENSORN/AN/AN/ARCIC is a steam turbine driven pump designed to deliver 400gpm over reactor pressure range of 150-1120 psig. Flowelement is located on pump disharge line ahead of the testreturn line to the CST tanks and injection line into "A"feedwater line. RCIC injects Into feedwater line prior to the lineentering containment.

Page 13: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Generating Plant Software Requirement Specificaton

Tide: Number

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 1 1

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/DigitalEngr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point-Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MOIPCSLPCI FLOWRHR100CONTAINMENT SPRAY/COOLING A LOOPLOW PRESSURE COOLANT INJECTION FLOWAGPMN/A010000N/AN/AS1SIGNAL INPUT FROM FLOW TRANSMITTERDISCHARGE OF RHR HEAT EXCHANGERSN/AN/A

N/A

HIGH & LOW SENSORN/AN/AN/ACONTAINMENT SPRAY/COOLING A LOOP flow is the RHRflow to the A loop drywell spray, torus spray and torus cooling.Each RHR pump is approximately rated at 4000 gpmdepending on system head. Two pumps are located in eachloop although flow can be cross tied between A and B loops.

Page 14: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Generatina Plant Software Reauirement Snecification

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 12

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data FeederNRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/DigitalEngr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MOIPCSLPCI FLOWRHR101CONTAINMENT SPRAY/COOLING B LOOPLOW PRESSURE COOLANT INJECTION FLOWAGPMN/A010000N/AN/AS1SIGNAL INPUT FROM FLOW TRANSMITTERDISCHARGE OF RHR HEAT EXCHANGERSN/AN/A

N/A

HIGH & LOW SENSORN/AN/AN/ACONTAINMENT SPRAY/COOLING B LOOP flow is the RHRflow to the B loop drywell spray, torus spray and torus cooling.Each RHR pump is approximately rated at 4000 gpmdepending on system head. Two pumps are located in eachloop although flow can be cross tied between A and B loops.

Page 15: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Generatina Plant Software Reaulrement Soecificaton

Tide: Number

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 13

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/DigitalEngr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSLPCI FLOWRHRI02RHR LOOP A INJECT FLOWLOW PRESSURE COOLANT INJECTION FLOWAGPMN/A010000N/AN/ASISIGNAL INPUT FROM FLOW TRANSMITTERDISCHARGE OF RHR HEAT EXCHANGERSN/AN/A

N/A

HIGH & LOW SENSORN/AN/AN/ARHR LOOP A INJECT FLOW is the RHR flow to the A RecircLoop, Reactor Head Cooling, Waste Surge Tank, and crosstie to B Loop. Each RHR pump is rated at about 4000 gpmdepending on system head. Two pumps are located in eachloop although flow can be cross tied between A and B loops.

Page 16: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northem States Power CompanyRAM-NaIn h. .n-r 9-anomfinn Dlant Reftumr Panialrommnt Anefle.atinn

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 14

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/DigitalEngr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSLPCI FLOWRHR103RHR LOOP B INJECT FLOWLOW PRESSURE COOLANT INJECTION FLOWAGPMN/A010000N/AN/AS1SIGNAL INPUT FROM FLOW TRANSMITTERDISCHARGE OF RHR HEAT EXCHANGERSN/AN/A

N/A

HIGH & LOW SENSORN/AN/AN/ARHR LOOP B INJECT FLOW is the RHR flow to the B RecircLoop and cross tie to A Loop. Each RHR pump is rated atabout 4000 gpm depending on system head. Two pumps arelocated in each loop although flow can be cross tied betweenA and B loops.

Page 17: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Generatino Plant Software Requirement Specification

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 15

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/DigitalEngr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MOIPCSCR SPRAY FLCSP1 00CS LOOP 11 FLOWCore Spray Cooling System FlowAGPMN/A05000N/AN/ASISIGNAL INPUT FROM FLOW TRANSMITTERON PUMP DISCHARGE LINE

N/A

N/A

HIGH & LOW SENSORN/A

N/AThe loop A Core Spray system consists of one electric drivenpump designed to deliver 3020 gpm against a system headcorresponding to a reactor pressure of 130psi abovecontainment pressure. The flow element is located on thepump discharge line just a head of the reactor vessel injectionand test return lines.

Page 18: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Generatina Plant Software Requirement Specification

Title: Number:

SIRS Process Computer System - Emergency Response Data ERDS-SRS-1-4 ISystem (ERDS) - Data Point Library

Sheet No: 16

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/DigitalEngr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSCR SPRAY FLCSP1 01CS LOOP 12 FLOWCORE SPRAY COOLING SYSTEM FLOWAGPMN/A05000N/AN/AS1SIGNAL INPUT FROM FLOW TRANSMITTERON PUMP DISCHARGE LINE

N/A

N/A

HIGH & LOW SENSORN/A

N/AThe loop B Core Spray system consists of one electric drivenpump designed to deliver 3020 gpm against a system headcorresponding to a reactor pressure of 1 30psi abovecontainment pressure. The flow element is located on thepump discharge line just a head of the reactor vessel injectionand test return lines.

Page 19: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Generatino Plant Software Requirement Specification

Ss te: Number

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 17

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/DigitalEngr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSDW ED SMP LVPCT138DW EQUIP DRAIN SUMP VOLDRYWELL FLOOR DRAIN SUMP LEVELAGALN/A164565N/AN/AS1SIGNAL INPUT FROM LEVEL TRANSMITTERDIRECTLY BELOW RX VESSEL IN DRYWELLN/AN/A

N/A

HIGH & LOW SENSORN/A

N/AThis sump collects liquid effluent from valve stem leak-offs, RxRecirc Pump and piping maintenance drains, vent coolerdrains, reactor well bulkhead and bellows drains, reactorvessel flange leakoff and Drywell Equipment Drain Sump heatexchanger drain. Two 50 GPM pumps discharge the water tothe Waste Collector Tank in the Reactor building. Sump Isisolated by Group II Isolation or manually from control room.Sump overflows into Drywell Floor Drain Sump at 1090Gallons.

I

I

Page 20: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMnn ielo N onr lenarnfinn Plant qnftwAnqm RAnIdir~m~nt Snpridmfr~inn

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 18

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/DigitalEngr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSDW FD SMP LVPCT139DW FLOOR DRAIN SUMP VOLDRYWELL FLOOR DRAIN SUMP LEVELAGALN/A164565N/AN/ASISIGNAL INPUT FROM LEVEL TRANSMITTERDIRECTLY BELOW RX VESSEL IN DRYWELLN/AN/A

N/A

HIGH & LOW SENSORN/A

N/AThis sump collects liquid effluent from Drywell cooler drains,floor drains, control rod drive leakage and drains, closedcooling water piping drains, and piping and equipmentmaintenance vents. Two 50 GPM pumps discharge the waterto the Floor Drain Collector Tank In the Reactor building.Sump is Isolated by Group II Isolation or manually from controlroom. Sump overflows Into Drywell Equipment Drain Sump at1090 Gallons.

I

Page 21: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nu.ear Genera.in_ Plant Software Requirement Specification

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 19

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MOIPCSEFF GAS RADPRM121STACK EFF MONITOR CH ARADIOACTIVITY OF RELEASED GASESAuCl/SN/A1lOE12N/AN/AS1SIGNAL FROM ANALOG OUTPUT OF MONITORFOUR ISOKINETIC PROBES IN OFF GAS STACKHI=3200, HI-HI=90000N/A

N/A

HIGH & LOW SENSORN/A

N/ASTACK EFF MONITOR CH A is a wide range gas monitorconsisting of isokinetic probe assembly, sample conditioningunit, sample detection unit, and Control Room panel. Thedetector assembly consists of low, mid, and high rangedetectors. Hi-Hi and/or INOP from both Channel A & Bmonitors will close valves to isolate off gas flow to the stack.

Page 22: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nudear Generating Plant Software Requirement Specfication

STite: Number:SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4

System (ERDS) - Data Point LibrarySheet No: 20

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSEFF GAS RADPRM122STACK EFF MONITOR CH BRADIOACTIVITY OF RELEASED GASESAuCI/SN/A1IOE12N/AN/ASISIGNAL FROM ANALOG OUTPUT OF MONITORFOUR ISOKINETIC PROBES IN OFF GAS STACKHI=3200, HI-HI=90000N/A

N/A

HIGH & LOW SENSORN/A

N/ASTACK EFF MONITOR CH B is a wide range gas monitorconsisting of isokinetic probe assembly, sample conditioningunit, sample detection unit, and Control Room panel. Thedetector assembly consists of low, mid, and high rangedetectors. Hi-Hi and/or INOP from both Channel A & Bmonitors will close valves to Isolate off gas flow to the stack.

Page 23: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Generating Plant Software Requirement Specification

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 21

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSEFF GAS RADPRM123RBV EFFLUENT MONITOR CH ARADIOACTIVITY OF RELEASED GASESAuCI/SN/A1lOE12N/AN/ASISIGNAL FROM ANALOG OUTPUT OF MONITORISOKINETIC PROBES IN EACH RX BLDG VENTHI=400, HI-HI=4500N/A

N/A

HIGH & LOW SENSORN/A

N/AReactor Building Vent Effluent Monitor Channel A is a widerange gas monitor consisting of isokinetic probe assemblies,sample conditioning unit, sample detection unit, and ControlRoom panel. The detector assembly consists of low, mid, andhigh range detectors.

Page 24: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMnnftimllo Ntiedar enerafinq Plant Software Reauirement Soecificadon

Title: Number:SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4

System (ERDS) - Data Point LibrarySheet No: 22

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSEFF GAS RADPRM124RBV EFFLUENT MONITOR CH BRADIOACTIVITY OF RELEASED GASESAuCI/SN/A

IE12N/AN/ASISIGNAL FROM ANALOG OUTPUT OF MONITORISOKINETIC PROBES IN EACH RX BLDG VENTHI=400, HI-HI=4500N/A

N/A

HIGH & LOW SENSORN/A

N/AReactor Building Vent Effluent Monitor Channel B is a widerange gas monitor consisting of isokinetic probe assemblies,sample conditioning unit, sample detection unit, and ControlRoom panel. The detector assembly consists of low, mid, andhigh range detectors.

Page 25: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Generatino Plant Software Requlrement Specification

Tide: Number:

S RS Process Computer System - Emergency Response Data ERDS-SRS-1-4 ISystem (ERDS) - Data Point Library

Sheet No: 23

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSEFF LIQ RADPRM1 07SERVICE WATER EFFLUENTRADIOACTIVITY OF RELEASED LIQUIDSACPSuCi/MI=((PRM107 in CPS)-5)*(4.3E-7).110E6N/ANIAS1SIGNAL INPUT FROM MONITORSAMPLES SW PRIOR TO SW LEAVING RX BLDGHI ALARM AS SET BY PLANT CHEMISTN/A

N/A

DOWNSCALE & UPSCALEN/A

N/AGamma radiation emitted by radioactive materials contained inprocess liquid are detected by a scintillation detector housedIn shielded sampler. Sidestream sample is used from theservice water line prior to leaving the Reactor Building. Afterleaving Reactor Building, line discharges into circ waterdischarge pipe. Alarm setpoints vary with plant operation asdetermined by plant chemist.

Page 26: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nudear Generating Plant Software Requirement Specification

Tide: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 24

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data FeederNRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSEFF LIQ RADPRM109RADWASTE EFFLUENTRADIOACTIVITY OF RELEASED LIQUIDSACPSuCi/MI=((PRM109 in CPS)-7)*(2.5E-6).11 OE6N/AN/ASISIGNAL INPUT FROM MONITORSAMPLED PRIOR TO LEAVING RADWASTE BLDGHI ALARM AS SET BY PLANT CHEMISTN/A

N/A

DOWNSCALE & UPSCALE, INOPN/A

N/AGamma radiation emitted by radioactive materials contained inprocess liquid are detected by a scintillation detector housedin shielded sampler. Liquid is sampled prior to leaving theRadwaste Building. After leaving Radwaste Building, linedischarges into discharge canal. Although Monticello haspermits, Monticello maintains a policy of zero liquid radwastereleases Into the river. Alarm setpoints vary with plantoperation as determined by plant chemist.

Page 27: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nudear Generatina Plant Software Requirement SDedfication

Title: I Number.

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4 ISystem (ERDS) - Data Point Library

Sheet No: 25

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSEFF LIQ RADPRM110TB NORMAL WASTE SUMP CH ARADIOACTIVITY OF RELEASED LIQUIDSACPMuCVMI=((PRMI 10 in CPM)-400)*(3.5E-9)101 OE6N/AN/AS1SIGNAL iNPUT FROM MONITORSAMPLED PRIOR TO LEAVING TURBINE BLDGHi ALARM AS SET BY PLANT CHEMISTNIA

N/A

DOWNSCALE & UPSCALE, INOPN/A

N/AGamma radiation emitted by radioactive materials contained inprocess liquid are detected by a scintillation detectors in drytube in sump. Sampled prior to leaving the Turbine Building.Alarm setpoints vary with plant operation as determined byplant chemist.

Page 28: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMontioello Nuclear Generatina Plant Software Reaulrement Spedfication

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 26

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MOIPCSEFF 110 RADPRM111TB NORMAL WASTE SUMP CH BRADIOACTIVITY OF RELEASED LIQUIDSACPMuCVMI=((PRM 1 1 in CPM) 400)*(3.5E-9)101 OE6N/AN/ASISIGNAL INPUT FROM MONITORSAMPLED PRIOR TO LEAVING TURBINE BLDGHI ALARM AS SET BY PLANT CHEMISTN/A

N/A

DOWNSCALE & UPSCALE, INOPN/A

N/AGamma radiation emitted by radioactive materials contained inprocess liquid are detected by a scintillation detectors in drytube in sump. Sampled prior to leaving the Turbine Building.Alarm setpoints vary with plant operation as determined byplant chemist.

Page 29: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northem States Power Company&Lnfi~lt% M, oear flanarnann Plant .qnffwjnrp Pont rmmnt flqtigmf

Title: Number

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 27

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSEFF LIQ RADPRM1 12DISCHARGE CANAL MONITOR ARADIOACTIVITY OF RELEASED LIQUIDSACPSuCi/MI=((PRM112 in CPSy2)*(1.4E-7).11 OE6N/AN/AS1SIGNAL INPUT FROM MONITOR550FT DOWNSTREAM FROM DISCHARGE STRUCTUREHi ALARM AS SET BY PLANT CHEMISTN/A

N/A

DOWNSCALE & UPSCALE, INOPN/A

N/AGamma radiation emitted by radioactive materials contained inprocess liquid are detected by a scintillation detectors. Sampleis drawn from 4 standpipes in canal 550 feet downstream fromthe discharge structure. Alarm setpoints vary with plantoperation as determined by plant chemist.

Page 30: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nudear Generating Plant Software Requirement Specification

S~~s T'itle: Number:SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4

System (ERDS) - Data Point LibrarySheet No: 28

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSEFF LIQ RADPRM113DISCHARGE CANAL MONITOR BRADIOACTIVITY OF RELEASED LIQUIDSACPSuCi/MI=((PRM1 13 in CPS)-2)*(1.4E-7).11 OE6N/AN/AS1SIGNAL INPUT FROM MONITOR550FT DOWNSTREAM FROM DISCHARGE STRUCTUREHI ALARM AS SET BY PLANT CHEMISTN/A

N/A

DOWNSCALE & UPSCALE, INOPN/A

N/AGamma radiation emitted by radioactive materials contained inprocess liquid are detected by a scintillation detectors. Sampleis drawn from 4 standpipes in canal 550 feet downstream fromthe discharge structure. Alarm setpoints vary with plantoperation as determined by plant chemist.

Page 31: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power Company1Armf1r11l fd,.A.SPr rsonamfinn Dion# CnfiursM Cn,-.IMn.Mn nrfefn

Ttl~e: Number

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 29

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond -Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSCND ANE RADPRMI 18OFFGASCH 1CONDENSER AIR EJECTOR RADIOACTIVITYAMR/HRN/A11 0E6N/AN/AS1SIGNAL OUTPUT FROM MONITORSAMPLE DRAWN FROM OFF GAS LINETRIP ON BOTH MONITORS UP,DOWN OR INOPN/A

N/A

LOWN/A

N/AOFF GAS CH 1 radiation monitor is positioned adjacent to avertical sample chamber. A continuous sample is drawn fromthe off gas line downstream from the Steam Jet Air Ejectorsand ahead of the Recombiner trains. The sample is monitoredafter a time delay of approximately 2 minutes to permitNitrogen-16 and Oxygen-19 to decay. Alarm setpoints varywith plant operation as determined by plant chemist.

Page 32: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Generatina Plant Software Requirement Specification

rifle:Process Computer System - Emergency Response DataSystem (ERDS) - Data Point Library

Number:ERDS-SRS-1 -4

Sheet No: 30

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSCND A/E RADPRMI 19OFF GAS CH 2CONDENSER AIR EJECTOR RADIOACTIVITYAMR/HRN/AI1 OE6N/AN/AS1SIGNAL OUTPUT FROM MONITORSAMPLE DOWNSTREAM OF STEAM JET AIR EJECTTRIP ON BOTH MONITORS UPDOWN OR INOPN/A

N/A

LOWN/A

N/AOFF GAS CH 2 radiation monitor Is positioned adjacent to avertical sample chamber. A continuous sample is drawn fromthe off gas line downstream from the Steam Jet Air Ejectorsand ahead of the Recombiner trains. The sample is monitoredafter a time delay of approximately 2 minutes to permitNitrogen-16 and Oxygen-19 to decay. Alarm setpoints varywith plant operation as determined by plant chemist.

Page 33: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMontcello Nuclear Generatina Plant Software Reaulrement Soecificatlon

Title:

SRS Process Computer System - Emergency Response DataSystem (ERDS) - Data Point Library

Number:ERDS-SRS-1 -4

Sheet No: 31

I

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSDW RADPCT109DRYWELL RADIATION CH ARADIATION LEVEL IN THE DRYWELLAR/HRN/AI10E8N/AN/AS1SIGNAL INPUT FROM RADIATION MONITORDRYWELL 180 DEGREE AZIMUTH AT 944'HI=50, HI-Hi=100N/A

N/A

HIGH SENSOR, INOPN/A

N/APurpose is to provide estimate of core damage by measuringdrywell gamma radiation fields caused by fission productleakage from the core. Each sensor is an ionization chamberwith an internal U-234 source which gives I R/HR reading foroperation verification. Elevation 944' is just below bottom ofreactor vessel (949').

Page 34: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Generafina Plant Software Requirement Spedfication

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4 ISystem (ERDS) - Data Point Library

Sheet No: 32

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder'NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:GenericlCond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSDW RADPCT1 1 0DRYWELL RADIATION CH BRADIATION LEVEL IN THE DRYWELLARIHRN/A11 0E8N/AN/AS1SIGNAL INPUT FROM RADIATION MONITORDRYWELL 0 DEGREE AZIMUTH AT 944'HI=50, HI-HI=100N/A

N/A

HIGH SENSOR, INOPN/A

N/APurpose is to provide estimate of core damage by measuringdrywell gamma radiation fields caused by fission productleakage from the core. Each sensor is an ionization chamberwith an internal U-234 source which gives 1 R/HR reading foroperation verification. Elevation 944' Is just below bottom ofreactor vessel (949').

Page 35: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Generating Plant Software Requirement Specification

Title: Number

SIRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 33

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:AlarmITrip Set Points:NJ Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSMN STEAM RAD

(not available)RADIATION LEVEL OF THE MAIN STEAM LINE

Not available to Process Computer System.

Page 36: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonnticelln Nudaar Generatina Plant Software Reautrement Soedfication

SMs Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 34

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSDW PRESSD23C001 0VALIDATED DRYWELL PRESSUREDRYWELL PRESSUREAPSIGN/A-5250N/AN/AP4WEIGHTED AVERAGE OF CONSISTENT DW PRESSSENSING LINES FROM DRYWELLALARMS LOW=0.1, HIGH=1.5N/A

N/A

HIGH & LOW SENSORN/A

N/AThis point consists of either a weighted average of allconsistent drywell pressure or an average of in-range drywellpressures if there are less than the required number ofconsistent singals. Four drywell pressure signals consist ofone narrow range (-2 to 3), one wide range (0 to 80) and twoaccident (-5 to 250) ranges. Weighted averages producesaverage that is weighted based on instrument accuracy.Drywell Internal design pressure is 56 PSIG at 281 Degrees F.At 2 PSIG, RPS initiates Reactor SCRAM and PrimaryContainment Isolation initiates Group 2 & 3.

Page 37: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northem States Power CompanyMonticello Nuclear Generatino Plant Software Requirement Specification

Title: Number:

SRtS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - bata Point Library

Sheet No: 35

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSDW TEMPD23C0310VALIDATED DRYWELL TEMPERATUREDRYWELL TEMPERATUREADEGFN/A0600N/AN/AP16AVERAGE OF CONSISTENT DW TEMPERAURES16 SENSORS AT 8 DRYWELL LOCATIONSHI=150 DEGFN/A

N/A

HIGH & LOW SENSORN/A

N/AThis point consists of either a weighted average bulktemperature of consistent regional temperatures or anunvalidated, non-weighted average of all in-range drywelltemperatures. Regional weighting factors compensate fordifferences In drywell volume at the various elevations. Eachlocation utilizes two sensors and are located in Drywell at: Elev932' (East & West), Elev 951'(North & South), Elev 970' (East& West), and Elev 994' (North & South).

I

Page 38: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

NorUtem States Power CompanyMonticello Nudear Generating Plant Software Requirement Specification

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 36

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSSP TEMPD23C0210VALIDATED TORUS TEMPERATURESUPPRESSION POOL TEMPERATUREADEGFN/A30240N/AN/AP16AVERAGE OF 2 SPOTMOS (8 SENSORS EACH)2 SENSORS IN EACH OF 8 TORUS SRV BAYSHIGH=90N/A

N/A

HIGH & LOW SENSOR, SPOTMOS INOPN/A

N/AVALIDATED TORUS TEMPERATURE is the average of theinputs from two Suppression Pool Temperature MonitoringSystems (SPOTMOS). Each system generates an average ofeight sensors. Each sensor Is located in one of the eight baysthat Safety Relief Valves discharge into.

I

I

Page 39: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Genera.in. Plant Software Requirement Specification

Tile: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 37

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:Ni Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSSP LEVELG43C001 5VALIDATED TORUS WATER LEVELSUPPRESSION POOL WATER LEVELAINCHESN/A-96180N/A0"=ELEVATION 910'= 530,000 GALLONSP4WEIGHTED AVERAGE OF CONSISTENT LEVELSLEVEL TAPS OFF TORUS SHELLHIGH=2, LO=-2N/A

N/A

HIGH & LOW SENSORN/A

N/AThis point consists of either a weighted average of allconsistent torus water levels or an average of in-range toruswater levels if there are less than the required number ofconsistent signals. Four torus water level signals consist oftwo narrow range (-15 to 15) and two wide range (-96 to 180).Weighted averages produce an average that is based onInstrument accuracy. HPCI suction transfer occurs at 2". TechSpecs level greater than -4" and less than 2.9".

Page 40: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyUnnfie-mlln NudjeApr GAneratinn Plant qnftwarp R~Aiirnm~nt SnAdflr~finn

Ttle: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 38

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MOIPCSH2 CONCPCT1 16PCTMT H2 ANALYZER ADRYWELL OR TORUS HYDROGEN CONCENTRATIONA

N/A020N/AN/AS1SIGNAL OUTPUT FROM H2 ANALYZERSAMPLE LINES UPPER DW,TORUS,CGCS IN & OUTN/AN/A

N/A

HIGH & LOW SENSOR, SYSTEM OFFN/A

N/AAnalyzers are normally shutdown and values will usually readless than 0.75%. System is capable of analyzing samples fromDrywell (elev 994), Torus and Combustible Gas ControlSystem inlet and outlet. Sample line and sample return valvesclose on Group 2 Isolation.

Page 41: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanySn-0ille KlI-1-~a tn2--fti- M..# t~ffiumroDn 12ho'monf tnorfirofnn1-1 I--II zuea - e Ie . -u UrAt VWI 'Uq~gE; tOAU

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 39

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data FeederNRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSH2 CONCPCTI17PCTMT H2 ANALYZER BDRYWELL OR TORUS HYDROGEN CONCENTRATIONA

N/A020N/AN/AS1SIGNAL OUTPUT FROM H2 ANALYZERSAMPLE LINES UPPER DW,TORUS,CGCS IN & OUTNIAN/A

NIA

HIGH & LOW SENSOR, SYSTEM OFFN/A

N/AAnalyzers are normally shutdown and values will usually readless than 0.75%. System is capable of analyzing samples fromDrywell (elev 994'), Torus and Combustible Gas ControlSystem inlet and outlet. Sample line and sample return valvesclose on Group 2 Isolation.

Page 42: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMnntficlln Nuclear Generatina Plant Software Reauirement Specfication

Tite: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-14System (ERDS) - Data Point Library

Sheet No: 40

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSH2 CONCPCT1 18PCTMT 02 ANALYZER ADRYWELL OR TORUS HYDROGEN CONCENTRATIONA

N/A025N/AN/AS1SIGNAL OUTPUT FROM 02 ANALYZERSAMPLE LINES UPPER DW,TORUS,CGCS IN & OUTN/AN/A

N/A

HIGH & LOW SENSOR, SYSTEM OFFN/A

N/AAnalyzers are normally shutdown and values will usually readless than 0.75%. System is capable of analyzing samples fromDrywell (elev 994'), Torus and Combustible Gas ControlSystem inlet and outlet. Sample line and sample return valvesclose on Group 2 Isolation. Normal operation concentrationsare 2.4%.

Page 43: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northem States Power CompanyUnnfiello Nudear renprabinn Plant Safhtw~re Reauirarnant Snadfic~finn

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 41

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92M01PCSH2 CONCPCT1 1 9PCTMT 02 ANALYZER BDRYWELL OR TORUS HYDROGEN CONCENTRATIONA

N/A025N/AN/AS1SIGNAL OUTPUT FROM 02 ANALYZERSAMPLE LINES UPPER DW,TORUS,CGCS IN & OUTN/AN/A

N/A

HIGH & LOW SENSOR, SYSTEM OFFN/A

N/AAnalyzers are normally shutdown and values will usually readless than 0.75%. System is capable of analyzing samples fromDrywell (elev 994'), Torus and Combustible Gas ControlSystem inlet and outlet. Sample line and sample return valvesdose on Group 2 Isolation. Normal operation concentrationsare 2.4%.

Page 44: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMnntic-Alln Niidler PnPrnfinn Plant Soffw~re Reaulrernent Snedflcation.. .. u w . . v .w..y ....._.......... - - r

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 42

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSCST LEVELCST100CST TANK LEVEL ACONDENSATE STORAGE TANK LEVELAFEETN/A530N/AN/AS1SIGNAL FROM LEVEL TRANSMITTERLEVEL TX ON WATER COLUMN IN RX BLDGHI=24'(225,600gal) LO=11.5'(1 08,1 00gal)N/A

N/A

LOWN/A

N/ACondensate Storage Tank (CST) Level A is the water level inthe A CST. Two CSTs exist with a tank capacity of 230,000gallons each. Makeup condensate water is provided through 3electric pumps from the CST tanks to various plant systems.Each tank has suction line for Control Rod Drive, HPCI, CoreSpray, RHR, and RCIC systems. At 7'(65,800gal) receiveCST Low-Low Level alarm and condensate service pumpstrip. At 2'8"(25,100gal) HPCI and RCIC transfer to Torussuction.

I

Page 45: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Generatina Plant Software Reauirement Soedfication

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 43

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:GenericlCond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSCST LEVELCST101CST TANK LEVEL BCONDENSATE STORAGE TANK LEVELAFEETN/A530N/AN/ASISIGNAL FROM LEVEL TRANSMITTERLEVEL TX ON WATER COLUMN IN RX BLDGHI=24'(225,600gal) LO=11 .5'(1 08,1 00gal)N/A

N/A

LOWN/A

N/ACondensate Storage Tank (CST) Level B is the water level inthe B CST. Two CSTs exist with a tank capacity of 230,000gallons each. Makeup condensate water is provided through 3electric pumps from the CST tanks to various plant systems.Each tank has suction line for Control Rod Drive, HPCI, CoreSpray, RHR, and RCIC systems. At 7'(65,800gal) receiveCST Low-Low Level alarm and condensate service pumpstrip. At 2'8"(25,100gal) HPCI and RCIC transfer to Torussuction.

I

Page 46: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyInAirallt Nuidawr laneratinn Pilnt I~nflimra RPemdrwm~nt RnoirIfie-tinn

TMe: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 44

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSWIND SPEEDMET102PRIMARY MET TOWER 43M AVG WIND SPEED AWIND SPEED AT THE REACTOR SITEAMPHN/A0100.00N/AN/AP115 MINUTE AVERAGE OF 5 SECOND VALUESPRIMARY MET TOWER AT 43 METER HEIGHTN/AN/A

N/A

HIGH & LOW SENSORN/A

N/AData is collected every five seconds, averaged every 15minutes, and stored in data files as 15-minute average.

Page 47: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Generatina Plant Software Reaulrement Snedfication

Ttle: NumberSRS Process Computer System - Emergency Response Data ERDS-SRS-1-4

System (ERDS) - Data Point LibrarySheet No: 45

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSWIND SPEEDMET103PRIMARY MET TOWER 43M AVG WIND SPEED BWIND SPEED AT THE REACTOR SITEAMPHN/A0100.00N/AN/AIP115 MINUTE AVERAGE OF 5 SECOND VALUESPRIMARY MET TOWER AT 43 METER HEIGHTN/AN/A

N/A

HIGH & LOW SENSORN/A

N/AData is collected every five seconds, averaged every 15minutes, and stored in data files as 15-minute average.

Page 48: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyIinnffllon I-1a-r fCanarfnn Olont Rnftumm RamilramonfArkw4finnfinn

vnJ .luil -uea sel1.sl~ra us.w-w. y-w w h-7-vTitle: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 46

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSWIND SPEEDMET104PRIMARY MET TOWER 100M AVG WIND SPEED AWIND SPEED AT THE REACTOR SITEAMPHN/A0100.00N/AN/AIP115 MINUTE AVERAGE OF 5 SECOND VALUESPRIMARY MET TOWER AT 100 METER HEIGHTN/AN/A

N/A

HIGH & LOW SENSORN/A

N/AData is collected every five seconds, averaged every 15minutes, and stored in data files as 15-minute average.

Page 49: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMontfiello Nudear Generatina Plant Software Reaulrement Soecification

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 47

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:AlarThrip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg: N/AUnique System Desc.:

01/07/92MO1PCSWIND SPEEDMET1 05PRIMARY MET TOWER 100M AVG WIND SPEED BWIND SPEED AT THE REACTOR SITEAMPHN/A0100.00N/AN/AP115 MINUTE AVERAGE OF 5 SECOND VALUESPRIMARY MET TOWER AT 100 METER HEIGHTN/AN/A

N/A

HIGH & LOW SENSORN/A

Data is collected every five seconds, averaged every 15minutes, and stored In data files as 15-minute average.

Page 50: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyUnnfinolln Nisdear (Genprafinn Plant Softwara Rantllromant SnadflifinainweBe w~ slwwBWM..._..-..- a r

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 48

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSWIND DIRMET106PRIMARY MET TOWER 43M AVG WIND DIRECT AWIND DIRECTION AT THE REACTOR SITEADEGFRNIA0540.00N/AN/AP115 MINUTE AVERAGE OF 5 SECOND VALUESPRIMARY MET TOWER AT 43 METER HEIGHTN/AN/A

N/A

HIGH & LOW SENSORN/A

N/AData is collected every five seconds, averaged every 15minutes, and stored in data files as 15-minute average.

Page 51: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power Company&nrstl-all KI-1 r12l -fl 0lno 1-6 l~n Qnfth.nr D-n..Iramant nvfr

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 49

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSWIND DIRMET1 07PRIMARY MET TOWER 43M AVG WIND DIRECT BWIND DIRECTION AT THE REACTOR SITEADEGFRN/A0540.00N/AN/AP115 MINUTE AVERAGE OF 5 SECOND VALUESPRIMARY MET TOWER AT 43 METER HEIGHTN/AN/A

N/A

HIGH & LOW SENSORN/A

N/AData is collected every five seconds, averaged every 15minutes, and stored in data files as 15-minute average.

Page 52: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nudear Generating Plant Software Requirement Spedfication

.Tte: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 50

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSWIND DIRMET1 08PRIMARY MET TOWER IOOM AVG WIND DIRECT AWIND DIRECTION AT THE REACTOR SITEADEGFRN/A0540.00N/AN/AP115 MINUTE AVERAGE OF 5 SECOND VALUESPRIMARY MET TOWER AT 100 METER HEIGHTN/AN/A

N/A

HIGH & LOW SENSORN/A

N/AData is collected every five seconds, averaged every 15minutes, and stored in data files as 15-minute average.

Page 53: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyIAn*II,~ .Ish.A D:lnn _QrJ4umra Ram dramanf Qnar4finafinn

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 51

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:Point ID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTurn-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSWIND DIRMET1 09PRIMARY MET TOWER IOOM AVG WIND DIRECT BWIND DIRECTION AT THE REACTOR SITEADEGFRN/A0540.00N/AN/AP115 MINUTE AVERAGE OF 5 SECOND VALUESPRIMARY MET TOWER AT 100 METER HEIGHTN/AN/A

N/A

HIGH & LOW SENSORN/A

N/AData Is collected every five seconds, averaged every 15minutes, and stored in data files as 15-minute average.

Page 54: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Generating Plant Software Requirement Specification

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 52

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:PointlD:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MO1PCSSTAB CLASSMET1 IOPRIMARY MET TOWER 43M AVG DELTA TEMP AAIR STABILITY AT THE REACTOR SITEADEGFN/A-9.09.0N/AN/APROC2AVERAGED DIFFERENTIALPRIMARY MET AT 10 & 43 METER HEIGHTN/AN/A

N/A

HIGH & LOW SENSORN/A

N/AData is collected every five seconds, averaged every 15minutes, and stored in data files as 15-minute average. Thisvalue represents the difference in temperature in degF/100ft.

Page 55: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMtntgllao Nudear GAnaratina Plant Software Reaulrement Soecification

Title: Number:SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4

System (ERDS) - Data Point LibrarySheet No: 53

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder.NRC ERDS Parameter:PointID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MOIPCSSTAB CLASSMET 11PRIMARY MET TOWER 43M AVG DELTA TEMP BAIR STABILITY AT THE REACTOR SITEADEGFN/A-9.09.0N/AN/APROC2AVERAGED DIFFERENTIALPRIMARY MET AT 10 & 43 METER HEIGHTN/AN/A

N/A

HIGH & LOW SENSORN/A

N/AData is collected every five seconds, averaged every 15minutes, and stored in data files as 15-minute average. Thisvalue represents the difference in temperature in degF/100ft.

Page 56: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Nortlhem States Power CompanyI&A-sN-l~kin -Ilh -1lE R... r~fln Plant .qnflwjrA Ram eirpmAnt An~r~fifetnnfn

Title: Number

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 54

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder.NRC ERDS Parameter:PointID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/921SAB CLASSMETI 12PRIMARY MET TOWER IOOM AVG DELTA TEMP AAIR STABILITY AT THE REACTOR SITEADEGFN/A-9.09.0N/AN/APROC2AVERAGED DIFFERENTIALPRIMARY MET AT 10 & 100 METER HEIGHTN/AN/A

N/A

HIGH & LOW SENSORN/A

N/AData is collected every five seconds, averaged every 15minutes, and stored In data files as 15-minute average. Thisvalue represents the difference in temperature in degF/100ft.

Page 57: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMnnfin!llo Niidear Generatinn Plant Softuare Reaulnemant Soeclficaffion

The: Number

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 55

I

DATA POINT LIBRARY REFERENCE FILE

Date:Reactor Unit:Data Feeder:NRC ERDS Parameter:PointID:Plant Spec Point Desc.:Generic/Cond Desc.:Analog/Digital:Engr Units/Dig States:Engr Units Conversion:Minimum Instr Range:Maximum Instr Range:Zero Point Reference:Reference Point Notes:PROC or SENS:Number of Sensors:How Processed:Sensor Location:Alarm/Trip Set Points:NI Detector Power SupplyCut-off Power Level:NI Detector Power SupplyTum-on Power Level:Instrument Failure Mode:Temperature CompensationFor DP Transmitters:Level Reference Leg:Unique System Desc.:

01/07/92MOIPCSSTAB CLASSMET1 13PRIMARY MET TOWER 1OOM AVG DELTA TEMP BAIR STABILITY AT THE REACTOR SITEADEGFN/A-9.09.0N/AN/APROC2AVERAGED DIFFERENTIALPRIMARY MET AT 10 & 100 METER HEIGHTN/AN/A

N/A

HIGH & LOW SENSORN/A

N/AData is collected every five seconds, averaged every 15minutes, and stored in data files as 15-minute average. Thisvalue represents the difference in temperature in degF/100ft.

Page 58: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Generating Plant Software Requirement Specification

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS)-- Data Point Library

Sheet No: 56

I. Contacts

Note: Please provide name, title, mailing address and phone number..

A. Survey Coordinator (i.e. contact for later clarification of questionnaire answers):Russell E. Van DellManager, Computer & Information SystemsNuclear Management CompanyMonticello Nuclear Generating Plant2807 West County Road 75Monticello, MN 55362(763) 295-1326

B. Computer Hardware Specialist(s).Lee LesmeisterInformation Technology AnalystNuclear Management CompanyMonticello Nuclear Generating Plant2807 West County Road 75 .Monticello, MN 55362(763) 295-1388

C. Systems Software Specialist(s):Bob AwdePrincipal Engineer

:,Nuclear Management CompanyMonticello Nuclear Generating Plant2807 West County Road 75Monticello, MN 55362(763) 271-5103

D. Application-level Software Specialist(s):Nai-Tai (Nelson) FeiSenior EngineerNuclear Management CompanyMonticello Nuclear Generating Plant2807 West County Road 75Monticello, MN 55362

.(763) 271-5180

Page 59: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nudear Generating Plant Software Requirement Spedfication

Tilte: Number:

SRS Process Computer System - Emergency Response Data FRDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 57

E. Telephone Systems Specialist(s):David SeestromInstrument EngineerNuclear Management Company |Monticello Nuclear Generating Plant2807 West County Road 75Monticello, MN 55362(763) 295-1376

Page 60: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nuclear Generating Plant Software Requirement Spedfication

Ss Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 58

I

II. Selection of Data Feeders

A. How many data feeders are there (six maximum)?

One - Process Computer System

B. Identify the selected data feeders and provide the following for each:

1. a short description of the categories of data points it will provide (e.g., met. rad.or plant data points, by unit) and

2. the rationale for selecting it if another system can also provide its categories ofdata points.

a) It is planned to provide both plant data points and meteorologicalinformation through the single feeder.

b) No other system is capable of providing requested information.

C. Which data feeder is the site time determining feeder? This should be the feeder whichis providing the majority of the data points.

Page 61: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power ComipanyMonticello Nuclear Generating Plant Software Requirement Specification

Title: Numnber~

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 59

III. Data Feeder Information

Note: A new Section IV must be filled out for each feeder system selected.

General Questions

A. Identification of Data Feeder

1. What is the name in local parlance given to this data feeder (e.g., EmergencyResponse Information System)? Please give both the acronym and the wordsforming it.

PCS - Process Computer System

2. Is this the site time determining feeder?

Yes

3. How often will this feeder transmit an update set to the ERDS (in seconds)?

60 Seconds

B. Hardware/Software Environment

1. Identify the manufacturer and model number of the data feeder hardware.

Digital Equipment Corporation VAX-4000-108

2. Identify the operating system.

VAX OpenVMS V7.1

3. What method of timekeeping is implemented on this feeder system (DaylightSavings, Standard, Greenwich)?

Daylight Savings

4. In what time zone is this feeder located?Central Standard Time Zone

Page 62: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northern States Power CompanyMonticello Nudear Generating Plant Software Requirement Specification

Title: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 60

I

C. Data Communication Details

1. Can this data feeder provide asynchronous serial data communication (RS-232-C) with full-modem control?

Yes

2. Will this feeder transmit in ASCII or EBCDIC?

ASCII

3. Can this feeder transmit at a serial baud rate of 2400 bps? If not, at what baudrate can it transmit?

Yes, 2400 bps can be used.

4. Does the operating system support XON/XOFF flow control?

Yes

a) Are any problems foreseen with the NRC using XON/XOFF to control thetransmission of data?No, however the use of SUSPEND and RESUME to control thetransmission of data works better as demonstrated in testing withHaliburton/NUS.

5. If it is not feasible to recontigure a serial port for the ERDS linkup (i.e., changethe baud rate, parity, etc.), please explain why.

Note Applicable.

6. Do any ports currently exist for the ERDS linkup?

Yes

a) If not, is it possible to add additional ports?

Not Applicable.

Page 63: Monticello - Emergency Response Data System (ERDS ... · Monticello Nuclear Generating Plant Commnted to NudearE ce~ece Operated by Nuclear Management Company, LLC L-MT-03-094 January

Northem States Power CompanyMonticelln Nudear Genarafina Plant Software Reauirement Snecificatlon

Tide: Number:

SRS Process Computer System - Emergency Response Data ERDS-SRS-1-4System (ERDS) - Data Point Library

Sheet No: 61

I

b) If yes, will the port be used solely by the ERDS or shared with other non-emergency-time users? Give details.

Port will be dedicated for ERDS.

D. Data Feeder Physical Environment and Management

1. Where is the data feeder located in terms of the TSC, EOF, and control room?

Computer Room located in Plant Administrative Building adjacent to Plant ControlRoom.

2. Is the data feeder protected from loss of supply of electricity?

Yes, PCS is provided with UPS (batteries with inverter and diesel generator).

3. Is there a human operator for this data feeder?

Yes

a) If so, how many hours a day is the feeder attended?

It is planned to have the Shift Emergency Communicator (SEC) initiate theERDS System per Emergency Implementing Procedures. An SEC is onduty 24 hours/day.