PROJECT TEAM: OWNER: LOCATION MAP: Architect McCall Architecture Project Manager: Mr. W.R. "Rusty" McCall 3308 Country Club Rd. Valdosta, Ga 31605 Phone: 229 - 242 - 2551 Fax: 229 - 244 - 8358 E - mail: [email protected] Owner GEORGIA BUREAU OF INVESTIGATIONS THOMSON, GA Structural Engineer Crews Engineering, Inc. Project Manager: Mr. Randall Crews 101 - B South Patterson Street Valdosta, Ga 31601 Phone: 229 - 244 - 3100 Fax: 229 - 244 - 4210 E - mail: [email protected] Civil Engineer EMC Engineering Services, Inc. Project Manager: Mr. Matthwe Inman 515 Saint Augustine Road, Suite E Valdosta, Ga 31601 Phone: 229 - 257 - 0399 Fax: 229 - 439 - 7979 E - mail: Matthew_Inman@emc - eng.com Electrical Engineer E.D.C, Inc. Project Manager: Mr. Michael Mongrue 1201 Broad Street, Suite 1A Augusta, Ga 30901 Phone: 706 - 724 - 3551 Fax: 706 - 724 - 8507 E - mail: [email protected] Mechanical Engineer ING Consulting Inc. Project Manager: Mr. John Lovin 550 11th Street, PO Box 1586 Augusta, Ga 30903 Phone: 706 - 774 - 1020 Fax: 706 - 774 - 0065 E - mail: [email protected] Cost Estimator ADE Construction Consultants, Inc. Project Manager: Mr. Dan Ergle 1298 Rockbridge Road, Suite A Stone Mountain, Ga 30087 Phone: 770 - 921 - 2701 Fax: 770 - 921 - 0932 E - mail: [email protected] CONSTRUCTION DOCUMENTS NOVEMBER 25, 2019 THOMSON, GEORGIA GEORGIA BUREAU OF INVESTIGATION THOMSON, GEORGIA PROJECT LOCATION 11/25/2019 GBI SEAL

Upload: others

Post on 12-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: M:PROJECTSGBI THOMSONRevit118109 GBI THOMSON …tgmechanical.net/documents/GBI Thomson Mech Only Plans.pdf · c:\users\allend\documents\118109 gbi thomson investigative office_allendyke.rvt

PROJECT TEAM:

OWNER:LOCATION MAP: ArchitectMcCall ArchitectureProject Manager: Mr. W.R. "Rusty" McCall3308 Country Club Rd.Valdosta, Ga 31605Phone: 229-242-2551Fax: 229-244-8358E-mail: [email protected]

OwnerGEORGIA BUREAUOF INVESTIGATIONS

THOMSON, GA

Structural EngineerCrews Engineering, Inc.Project Manager: Mr. Randall Crews101-B South Patterson StreetValdosta, Ga 31601Phone: 229-244-3100Fax: 229-244-4210E-mail: [email protected]

Civil EngineerEMC Engineering Services, Inc.Project Manager: Mr. Matthwe Inman515 Saint Augustine Road, Suite EValdosta, Ga 31601Phone: 229-257-0399Fax: 229-439-7979E-mail: [email protected]

Electrical EngineerE.D.C, Inc.Project Manager: Mr. Michael Mongrue1201 Broad Street, Suite 1AAugusta, Ga 30901Phone: 706-724-3551Fax: 706-724-8507E-mail: [email protected]

Mechanical EngineerING Consulting Inc.Project Manager: Mr. John Lovin550 11th Street, PO Box 1586 Augusta, Ga 30903Phone: 706-774-1020Fax: 706-774-0065E-mail: [email protected]

Cost EstimatorADE Construction Consultants, Inc.Project Manager: Mr. Dan Ergle1298 Rockbridge Road, Suite AStone Mountain, Ga 30087Phone: 770-921-2701Fax: 770-921-0932E-mail: [email protected]

CONSTRUCTION DOCUMENTS NOVEMBER 25, 2019

THOMSON, GEORGIA

GEORGIA BUREAU OFINVESTIGATION

THOMSON, GEORGIA

PROJECT LOCATION

11/25/2019

GBI SEAL

Page 2: M:PROJECTSGBI THOMSONRevit118109 GBI THOMSON …tgmechanical.net/documents/GBI Thomson Mech Only Plans.pdf · c:\users\allend\documents\118109 gbi thomson investigative office_allendyke.rvt

TITLE

XX

ELEVATION CALLOUT

DETAIL CALLOUT

DETAIL CALLOUT

SECTION CALLOUT COLUMN TAG

DRAWING TITLE

DOOR TAG

KEY TAG

REVISION CLOUD

SYMBOL KEY

ROOM TAG

WALL TAG

WINDOW TAG SHEET NO:

FILE NO:

PROJECT NO:

APPROVED:

DRAWN:

SCALE:

ISSUE:

DATE:

SHEET TITLE:

PROJECT TITLE:

ARCHITECT:

SEAL:

CONSULTANT:

# DATE:

AS SHOWN

2019 McCALL & ASSOCIATES, INC.C

1 72 3 4 5 6

1 72 3 4 5 6

A

B

E

C

D

A

B

E

C

D

Physical Address:3308 Country Club Rd.

Valdosta, GA 31605

Mailing Address:P.O. Box 5146

Valdosta, GA 31603Phone: 229.242.2551

Fax: 229.244.8358

www.mccallinc.com

These Contract Documents are the exclusive property of McCall and Associates, Inc. Any reproduction, modidication, disclosure and/ or use of these materials ( or any portion of them) without McCall and Associstes, Inc. prior written consent is strictly prohibited.

NAME:

4/1/2020 4:39:58 PM

C:\U

sers

\alle

nd\D

ocum

ents

\118

109

GBI

TH

OM

SON

INVE

STIG

ATIV

E O

FFIC

E_Al

lenD

yke.

rvt

1 AWJ REVISION 06-20-16

G001

118109

118109 G001

WRM

AWD

CONSTRUCTION DOCUMENTS

NOVEMBER 25, 2019

GENERAL NOTES, INDEXTO DRAWINGS

GBI - 059 THOMSONINVESTIGATIVE OFFICE

THOMSON, GEORGIA

MINIMUM PLUMBING FACILITIES PER TABLE 2902.1

WATER CLOSETS(MEN)

LAVATORIES(MEN)

WATER CLOSETS(WOMEN)

LAVATORIES(WOMEN) DRINKING FOUNTAIN SERVICE SINK

FIRE RATINGS FOR CONSTRUCTION TYPE

STRUCTURALFRAME

BEARING WALL -EXTERIOR

BEARING WALL -INTERIOR FLOOR ROOF

0 0 0 0 00 0 0 0 00 0 0 0 0

ALLOWABLE BUILDING HEIGHT AND AREA - OFFICE

OCCUPANCY TYPE OF CONSTRUCTION

ALLOWEDBUILDING HEIGHT

(FLOORS) ALLOWED AREA PROVIDED AREA

BUSINESS II-B 3 23,000 11,387ASSEMBLY - A3 II-B 2 9,500 517

Not Placed

INTERIOR FINISH CLASS

OCCUPANCY EXITS CORRIDORS ROOMS

BUSINESS B C CSTORAGE C C CASSEMBLY - A3 B B C

1. All work performed shall be in strict compliance with governingfederal, state, and local building code requirements, disability actregulations, executed in accordance with accepted industrystandards and shall conform to specific regulations as mandated bythe owner, the tenant, and the architect.

2. Refer to technical specifications for additional requirements.

3. The Contractors shall investigate, verify and be responsible forall conditions of the project and shall notify the Architect of anyconditions requiring modifications or any discrepancies between thedrawings and existing conditions prior to proceeding with work.

4. Contractor shall protect all in place construction, landscaping,paving, utilities, etc., from damage during construction. All damagedconstruction, paving, landscaping, etc., to be restored to originalcondition.

5. Notes appear on various sheets for different systems andconstruction material. All sheets are to be reviewed and notes onany one sheet are to be applied to all related drawings and details.

6. Details not shown are similar in character to those detailed.Where specified dimensions, details or design intent cannot bedetermined, consult the Architect prior to proceeding with the work.

7. Do not scale drawings.

8. Should any conflict occur between, MEP, FP, Structural andArchitectural drawings, Architectural drawings shall supersede allothers. Contractor shall notify Architect immediately for interpretation.

9. Partitions are dimensioned to the center of stud walls or faceof C.M.U. walls unless noted otherwise.

10. All dissimilar metals shall be effectively isolated from eachother to avoid molecular breakdown.

11. Refer to Plumbing Drawings for locations of all floor drains,trench drains, sumps and subsoil drainage unless noted otherwise.

12. All penetrations of ductwork, conduit, piping and similar workthrough fire rated assemblies shall be sealed to maintain the ratingof the assembly with a UL approved material.

13. See Structural Drawings for exact location size and thickness ofall structural elements.

14. A finish or Fire rating indication on a wall shall mean theentire length of wall is to be finished or Fire rated as indicated.

15. General Contractor shall coordinate all equipment base andhousekeeping pads with Mechanical, Plumbing and Electricalcontractors. Equipment base and housekeeping pads to be aminimum of 4" high and to be installed beneath the projected areaof equipment.

GENERAL NOTES

16. General contractor shall coordinate all mechanical and electricalfloor and wall sleeves and all mechanical shafts with mechanical,plumbing, fire protection, electrical, structural and architecturaldrawings.

17. Construction of work indicated on the drawings as (NIC) is notincluded in this contract. Subsequent drawings and specifications willbe submitted for separate approval or this work will be completed byothers outside this scope of work.

18. Coordinate placement of all ceiling elements with mechanical,electrical and fire protection installer. Where discrepancies existbetween drawings and installation, consult the architect prior toproceeding.

19. All material quantities shall be coordinated with architectural,civil, structural, MEP & FP drawings and shall not be limited to anysingle discipline.

20. All switches and controls for lights, heat, ventilation, windowtreatments, fire alarms, and all similar controls of frequent oressential use shall be placed within reach for individuals inwheelchairs as required by the Georgia Accessibility code.

21. Omissions from the drawings, specifications or the details ofwork which is customarily performed, shall not relieve the contractorfrom performing such omitted or mis-described details of the work.All work shall be performed as fully and correctly as set forth anddescribed in the drawings and specifications.

22. Subcontractors bidding this project should carefully review allpages of the plans. Items under their sub-trade may be denotedon sheets other than those specifically marked C, A, S, M, FP, E or P.General contractor should insure that subcontractors review completesets of drawings.

23. The contractor shall coordinate all portions of the work asdescribed in the construction documents.

24. These construction documents are the exclusive property ofMcCall and Associates, Inc. Any reproduction, modification, disclosureand/or use of these materials (or any portion of them) withoutMcCall and Assoc. prior written consent is strictly prohibited.

25. The contractor and all subcontractors shall visit the site, reviewthe contract documents, permit requirements and become thoroughlyfamiliar with the conditions of this site prior to submitting a bid.

26. The contractor shall provide the following items: 1) Transition strips where all dissimilar floor finishes meet. 2) Blocking for all items to be anchored or secured to walls,

floors and ceilings. 3) Conceal all piping & conduit in walls, floors, above ceilings,

etc.

27. All permits must be at the job site at all times during ongoingconstruction.

28. This project must be supervised by the contractor's personnelat all times.

29. The general contractor shall bear the full responsibility andcosts for the following: a. Temporary power and utilities. B. Trash removal. C. Liability and workman's compensation insurance.

30. All connectors and fasteners that are in contact with pressuretreated wood must be at least g185 hot dipped galvanized.

BUILDING CODE SUMMARY

ARCHITECTURAL

A101 ARCHITECTURAL SITE PLAN-PHASE IA102 ARCHITECTURAL SITE PLAN-PHASE IIA103 ARCHITECTURAL SITE PLAN-PHASE IIIA104 FINAL ARCHITECTURAL SITE PLANA105 FLOOR PLAN - OFFICEA106 REFLECTED CEILING PLAN - OFFICEA107 MEZZANINE FLOOR PLAN - OFFICEA108 ROOF PLAN - OFFICEA109 GARAGE PLANSA200 EXTERIOR ELEVATIONS - OFFICEA201 EXTERIOR ELEVATIONS - GARAGEA300 BUILDING AND WALL SECTIONS - OFFICEA301 BUILDING AND WALL SECTIONS - GARAGEA400 ENLARGED PLANS AND INTERIOR ELEVATIONSA401 FRONT ENTRANCE DETAILS - OFFICEA500 ELEVATIONS AND DETAILSA600 SCHEDULES AND DETAILSA700 LIFE SAFETY PLAN - OFFICEA701 LIFE SAFETY PLAN - GARAGE

GENERAL

G000 COVERG001 GENERAL NOTES, INDEX TO DRAWINGSG002 SURVEY SHEET 1G003 SURVEY SHEET 2

INDEX TO DRAWINGS

OWNER:

PROJECT NAME:

PROJECT ADDRESS

GBI - 059 THOMSON INVESTIGATIVE OFFICE

THOMSON, GEORGIA

GEORGIA BUREAU OFINVESTIGATION

CODE COMPLIANCE

NFPA 101 LIFE SAFETY CODE 2012 EDITION, WITH GEORGIA AMENDMENTS

INTERNATIONAL BUILDING CODE: 2012 EDITION, WITH GEORGIA AMENDMENTSINTERNATIONAL FIRE CODE: 2012 EDITION, WITH GEORGIA AMENDMENTSINTERNATIONAL PLUMBING CODE: 2012 EDITION WITH GEORGIA AMENDMENTSINTERNATIONAL MECHANICAL CODE: 2012 EDITION, WITH GEORGIA AMENDMENTSINTERNATIONAL FUEL GAS CODE: 2012 EDITION, WITH GEORGIA AMENDMENTSNATIONAL ELECTRIC CODE: 2017 EDITION, WITH NO GEORGIA AMENDMENTSINTERNATIONAL ENERGY CONSERVATION CODE 2009 EDITION, W/ GEORGIA SUPPLEMENTS AND AMENDMENTS

2010 ADA ACCESSIBILITY STANDARDS

(THE PROJECT SHALL MEET OR EXCEED THE FOLLOWING CODE REQUIREMENTS)

N.F.P.A. 13 NATIONAL FIRE PROTECTION ASSOCIATIONN.F.P.A. 120-3-3 RULES AND REGULATIONS OF THE SAFETY FIRE COMMISSIONER

4 PROVIDED 4 PROVIDED 4 PROVIDED 4 PROVIDED 2 PROVIDED 2 PROVIDED

0.2

STORAGE S-1

STORAGE S-1

STORAGE S-1

0.2

CIVILC100 GENERAL NOTES AND LEGENDC200 EXISTING CONDITIONSC300 PHASE 1-DEMOLITION AND CONSTRUCTION PLANC301 PHASE 2-DEMOLITION AND CONSTRUCTION PLANC302 PHASE 3-DEMOLITION AND CONSTRUCTION PLANC400 SITE PLANC500 INITIAL UTILITY PLANC501 FINAL UTILITY PLANC600 PAVING, GRADING, AND DRAINAGE PLANC700 HYDROLOGY PLANC800 GDOT EXISTING CONDITIONS & DEMOLITION PLANC801 GDOT SITE & STRIPING PLANC802 GDOT PAVING, GRADING, AND DRAINAGE PLANC803 GDOT- ESPC PLANC900 CONSTRUCTION DETAILSC901 CONSTRUCTION DETAILSC902 CONSTRUCTION DETAILSC1000 INITIAL PHASE 1- ESPC PLANC1001 INTERMEDIATE PHASE 1- ESPC PLANC1002 INITIAL PHASE 2- ESPC PLANC1003 INTERMEDIATE PHASE 2 - ESPC PLANC1004 FINAL PHASE 3- ESPC PLANC1005 ESPC NOTESC1006 ESPC NOTESC1007 ESPC DETAILSLOG LOGISTICS PLANC-PP PLOT PLAN

STRUCTURAL

S101 GENERAL NOTESS201 FOUNDATION AND SLAB PLAN - OFFICES202 MEZZANINE FRAMING PLAN AND DETAILSS203 ROOF FRAMING PLANS204 FOUNDATION AND SLAB PLAN - GARAGES401 MASONRY SECTIONS AND DETAILS

ELECTRICAL

E100 LEGEND, NOTES, DETAILS AND FIXTURE SCHEDULEE101 ELECTRICAL SITE PLANE102 LIGHTING, POWER, AND SYSTEMS PLAN - MEZZANINEE201 LIGHTING PLANE202 LIGHTING, POWER, MECHANICAL POWER, AND SYSTEMS PLANE301 POWER PLANE401 MECHANICAL POWER PLANE501 FIRE ALARM SYSTEM PLANE600 RISER DIAGRAM & PANEL SCHEDULESE700 DETAILSE701 DETAILS

PLUMBING

P001 PLUMBING LEGEND, SCHEDULES, AND DETAILSP002 PLUMBING DETAILSP101 OFFICE - SANITARY AND VENTP102 OFFICE - DOMESTIC WATER AND VENTP103 MEZZANINE - SANITARY AND VENTP104 GARAGE - SANITARY, VENT, AND DOMESTIC WATER PIPINGP201 OVERALL PLUMBING ISOMETRIC

MECHANICAL

M001 HVAC SCHEDULESM002 MECHANICAL DETAILSM101 MECHANICAL- OFFICE BUILDINGM102 MECHANICAL - MEZZANINE LEVELM103 MECHANICAL- DETAIL VIEWSM104 MECHANICAL- CONDENSATE AND REFRIGERANTM201 MECHANICAL- EVIDENCE GARAGE

FIRE PROTECTION

FP101 FIRE SPRINKLER HAZARD ANALYSIS

TOTAL OCCUPANT LOAD FOR OFFICE BUILDING = 149TOTAL OCCUPANT LOAD FOR MAINTENANCE BUILDING = 6

TOTAL REQUIRED WIDTH FOR OFFICE BUILDING = 29.80

TOTAL REQUIRED WIDTH FOR GARAGE BUILDING = 2.20

0.2

7.0022.80

2.20

CONFERENCE-A3 528 SF 35

528

35 CONFERENCE-A3

CONFERENCE-A3

TELECOMMUNICATIONS

T100 TELECOMMUNICATIONS PLAN

TOTAL OFFICE BUILDING SQUARE FOOTAGE = 11,915 S.F.

EXISITNG GARAGE BUILDING SQUARE FOOTAGE = 1,421 S.F.ADDITIONAL GARAGE BUILDING SQUARE FOOTAGE = 1,876 S.F. TOTAL GARAGE = 3,297 S.F.

OFFICE BUILDING

GARAGE

CONFERENCE - A3

ALLOWABLE BUILDING HEIGHT AND AREA - GARAGE

OCCUPANCY TYPE OF CONSTRUCTION

ALLOWEDBUILDING HEIGHT

(FLOORS) ALLOWED AREA PROVIDED AREA

STORAGE II-B 2 17,500 1,876STORAGE S-1

OFFICE BUILDING

GARAGE

TOTAL = 11,915

OCCUPANT LOAD

OCCUPANCY AREA PERSON/S.F. TOTAL

3,297 SF 11

11,387 SF 114 BUSINESS

15

300

100

OCCUPANCY SPRINKLERED/ # OF PEOPLE EGRESS PER REQUIRED WIDTH NON SPRINKLERED PERSON

EGRESS WIDTH CALCULATION

SPRINKLERED

NON SPRINKLERED

BUSINESS 0.2 1.20SPRINKLERED 114

11

Page 3: M:PROJECTSGBI THOMSONRevit118109 GBI THOMSON …tgmechanical.net/documents/GBI Thomson Mech Only Plans.pdf · c:\users\allend\documents\118109 gbi thomson investigative office_allendyke.rvt

SHEET NO:

FILE NO:

PROJECT NO:

APPROVED:

DRAWN:

SCALE:

ISSUE:

DATE:

SHEET TITLE:

PROJECT TITLE:

ARCHITECT:

SEAL:

CONSULTANT:

# DATE:

AS SHOWN

2019 McCALL & ASSOCIATES, INC.C

1 72 3 4 5 6

1 72 3 4 5 6

A

B

E

C

D

A

B

E

C

D

Physical Address:3308 Country Club Rd.

Valdosta, GA 31605

Mailing Address:P.O. Box 5146

Valdosta, GA 31603Phone: 229.242.2551

Fax: 229.244.8358

www.mccallinc.com

These Contract Documents are the exclusive property of McCall and Associates, Inc. Any reproduction, modidication, disclosure and/ or use of these materials ( or any portion of them) without McCall and Associstes, Inc. prior written consent is strictly prohibited.

NAME:

4/3/2020 4:29:51 PM

Q:\

127 -

The M

cC

all

Com

panie

s\1

27-1

903 -

GB

I T

hom

son\M

EC

H\M

EC

H.r

vt

M001

118109

118109 M001

SAP

JKF

CONSTRUCTION DOCUMENTS

NOVEMBER 25, 2019

MECHANICAL SCHEDULES

GBI - 059 THOMSONINVESTIGATIVE OFFICE

THOMSON, GA

HEAT PUMP SCHEDULE

TAG MANUFACTURER MODEL NOMINAL TONSCOOLING

CAPACITY (BTUh)HEATING

CAPACITY (BTUh)

ELECTRICALWEIGHT (LBS) IEER EER OPTIONS

VOLTAGE PHASE MCA MOCP

HP-1 MITSUBISHI TPURY-P168 14.0 168,000 188,000 208 3 61/57 100/90 780 21.3 10.6 1,2,3,4,5

HP-2 MITSUBISHI TPURY-P168 14.0 168,000 188,000 208 3 61/57 100/90 780 21.3 10.6 1,2,3,4,5

HP-3 MITSUBISHI TPUMY-P48NKMU2 4.0 48,000 54,000 208 1 29 44 290 - 13.1 1,2,5

FAN COIL SCHEDULE

TAG MANUFACTURER MODELNOMINAL

TONSMOUNT

FANCFM

ESP(in. wg.)

VENTILATIONAIR (CFM)

ASSOCIATEDHP

COOLINGCAPACITY (BTUh)

HEATINGCAPACITY (BTUh)

ELECTRICAL WEIGHT(LBS)

OPTIONSVOLTAGE PHASE MCA MOCP

FC-1 MITSUBISHI TPLFY-P12NCMU-E 1.0 CEILING CASSETTE 335 - 20 HP-1 12,000 13,500 208 1 0.35 15 35 1,2,6,7

FC-2 MITSUBISHI TPLFY-P12NCMU-E 1.0 CEILING CASSETTE 335 - 20 HP-1 12,000 13,500 208 1 0.35 15 35 1,2,6,7

FC-3 MITSUBISHI TPLFY-P24NBMU-E 2.0 CEILING CASSETTE 812 - 100 HP-2 24,000 27,000 208 1 0.54 15 55 1,2,6,7

FC-4 MITSUBISHI TPLFY-P12NCMU-E 1.0 CEILING CASSETTE 335 - 20 HP-2 12,000 13,500 208 1 0.35 15 35 1,2,6,7

FC-5 MITSUBISHI TPLFY-P15NBMU-E 1.25 CEILING CASSETTE 390 - 100 HP-1 15,000 17,000 208 1 0.35 15 35 1,2,6,7

FC-6 MITSUBISHI TPEFY-P48NMHU-OA 4.0 SUSPENDED 600 1.00 - HP-1 48,000 54,000 208 1 3.3 15 110 1,2,4,7

FC-7 MITSUBISHI TPKFY-P06NBMU-E 0.5 WALL 210 - - HP-1 6,000 6,700 208 1 0.19 15 25 2,3,6,7

FC-8 MITSUBISHI TPKFY-P06NBMU-E 0.5 WALL 210 - - HP-1 6,000 6,700 208 1 0.19 15 25 2,3,6,7

FC-9 MITSUBISHI TPKFY-P06NBMU-E 0.5 WALL 210 - - HP-2 6,000 6,700 208 1 0.19 15 25 2,3,6,7

FC-10 NOT USED NOT USED - - - - - - - - - - - - - -

FC-11 MITSUBISHI TPKFY-P06NBMU-E 0.5 WALL 210 - - HP-2 6,000 6,700 208 1 0.19 15 25 2,3,6,7

FC-12 MITSUBISHI TPKFY-P06NBMU-E 0.5 WALL 210 - - HP-2 6,000 6,700 208 1 0.19 15 25 2,3,6,7

FC-13 MITSUBISHI TPVFY-P30NAMU 2.5 HORIZONTAL 875 0.8 120 HP-1 30,000 34,000 208 1 4.13 15 150 2,4,5,6,7

FC-14 MITSUBISHI TPVFY-P12NAMU 1.0 HORIZONTAL 400 0.8 60 HP-1 12,000 13,500 208 1 3.0 15 120 2,4,5,6,7

FC-15 MITSUBISHI TPVFY-P18NAMU 1.5 HORIZONTAL 585 0.8 80 HP-2 18,000 20,000 208 1 3.0 15 120 2,4,5,6,7

FC-16 MITSUBISHI TPVFY-P30NAMU 2.5 HORIZONTAL 875 0.8 120 HP-1 30,000 34,000 208 1 4.13 15 150 2,4,5,6,7

FC-17 MITSUBISHI TPVFY-P24NAMU 2.0 HORIZONTAL 735 0.8 140 HP-2 24,000 27,000 208 1 3.0 15 150 2,4,5,6,7

FC-18 MITSUBISHI TPVFY-P24NAMU 2.0 HORIZONTAL 735 0.8 260 HP-2 24,000 27,000 208 1 3.0 15 150 2,4,5,6,7

FC-19 MITSUBISHI TPVFY-P18NAMU 1.5 HORIZONTAL 585 0.8 85 HP-1 18,000 20,000 208 1 3.0 15 120 2,4,5,6,7

FC-20 MITSUBISHI TPEFY-P48NMHU-OA 4.0 SUSPENDED 600 1.00 - HP-2 48,000 54,000 208 1 3.3 15 110 1,2,4,7

FC-21 MITSUBISHI TPVFY-P48NAMU 4.0 HORIZONTAL 1,400 0.8 120 HP-4 48,000 54,000 208 1 5.63 15 200 2,4,5,6

OPTIONS:1. LOW AMBIENT KIT2. VARIABLE SPEED COMPRESSOR3. TWINNING KIT4. UNIT REQUIRES TWO ELECTRICAL CONNECTIONS. COORDINATE WITH ELECTRICAL CONTRACTOR. FIELD INSTALLED, FUSED DISCONNECT BY ELECTRICAL5. SIMULTANEOUS HEAT AND COOL

BRANCH CONTROLLER SCHEDULE

TAG MANUFACTURER MODEL NUMBER OF BRANCHES ASSOCIATED UNITELECTRICAL

WEIGHT (LBS) OPTIONSVOLTAGE PHASE MCA

BC-1 MITSUBISHI TCMBM1012 12 HP-1 208 1 1.57 150 ALL

BC-2 MITSUBISHI TCMBM1012 12 HP-2 208 1 1.57 150 ALL

OPTIONS:1. SIMULTANEOUS HEATING AND COOLING OPERATION

OPTIONS:1. INTEGRAL CONDENSATE PUMP2. MANUFACTURER'S SUPPLIED AIR FILTER. SUPPLY 1 EXTRA FILTER PER UNIT ATTIC STOCK.3. BLUE DIAMOND MICRO BLUE CONDENSATE PUMP INSTALLED ABOVE CEILING4. FIELD INSTALLED FUSED DISCONNECT5. THREE STAGE FAN6. LOCAL WIRED CONTROL. REFERENCE MITSUBISHI MA MODEL.7. CONNECTED TO CENTRAL CONTROLLER. REFERENCE MITSUBISHI AE-200A

EXHAUST FAN SCHEDULE

TAG MANUFACTURER MODEL FAN CFM FAN HP ESP (IN. W.C.)ELECTRICAL

SONES WEIGHT (LBS) OPTIONSVOLTAGE PHASE MCA MOCP

EF-1 GREENHECK CSP-A110 100 - 0.15 115 1 0.6 15 1.5 20 7,8,9

EF-2 GREENHECK CUE-131 1,300 1/6 0.3 115 1 4.4 15 11.5 75 1-6

EF-3 GREENHECK CSP-A200 200 - 0.25 115 1 0.4 15 1.0 25 7,10,11

OPTIONS:1. FACTORY MOUNTED ELECTRICAL DISCONNECT2. ½" STEEL SECURITY BARS ON INTERIOR WITH 6" SPACING3. GRAVITY OPERATED DAMPER EQUAL TO WD-110-12x12. GALVANIZED DAMPER GUARD.4. SHORT WALL HOUSING WITH FLUSH EXTERIOR, BIRDSCREEN AND OSHA GUARD5. NEMA-1 TOGGLE DISCONNECT6. HAND/OFF/AUTO MOTOR STARTER WITH DAMPER CONTROL CAPABILITY EQUAL TO WALL MOUNTED GREENHECK #MSEM NEMA 3R.7. COORDINATE WITH ELECTRICAL FOR DISCONNECT8. CONTINUOUS OPERATION9. BACKDRAFT DAMPER10. WALL CAP WITH BIRDSCREEN AND BACKDRAFT DAMPER EQUAL TO GREENHECK WC-0811. INTERLOCKED WITH FIRE SUPRESSION SYSTEM FM200 (SEE FIRE PROTECTION PLAN). ACTIVATED ONLY DURING PURGE CYCLE

LOUVER SCHEDULE

TAG MANUFACTURER MODEL WxHxD (IN) SERVICEFREE AREA

(SQ.FT.)VOLUME CFM VELOCITY FPM ESP (in.wg.) OPTIONS

LV-1 GREENHECK ESD-435 32x32x4 EXHAUST 3.5 1,300 400 0.03 1,2,3,7

LV-2 GREENHECK ESD-435 32x32x4 INTAKE 3.5 1,300 400 0.03 1,2,3,7

LV-3 GREENHECK EAC-401 32x32x4 INTAKE 2.7 1,300 500 0.03 1,2,3,4,5,6,7

OPTIONS:1. DRAINABLE HEAD, GUTTERS ON BLADES, AND DOWNSPOUTS IN JAMBS2. STATIONARY HORIZONTAL BLADE LOUVER3. ALUMINUM FLAT-EXPANDED BIRD SCREEN ON INTERNAL SIDE OF LOUVER4. VERTICAL ½" STEEL SECURITY BARS ON INTERIOR AND WITH 6" SPACING 5. COMBINATION LOUVER AND AIR SHUT-OFF DAMPER. NEMA 3R DAMPER MOTOR AND INTERLOCKED WITH EF-01 INTELLIGENT STARTER6. FLANGE FRAME7. KYNAR FINISH. COLOR SELECTED BY ARCHITECT

AIR DEVICE SCHEDULE

TAG MANUFACTURER MODEL DESCRIPTION DEFLECTION SERVICE MOUNTING MATERIAL SIZE OPTIONS

A TITUS OMNI SQUARE PLAQUE 4-WAY SUPPLY LAY-IN STEEL 24 x 24 1

B TITUS OMNI SQUARE PLAQUE 4-WAY SUPPLY SURFACE STEEL 24 x 24 1,6,7

C TITUS OMMI SQUARE PLAQUE 4-WAY SUPPLY SURFACE STEEL 24 x 24 1

D TITUS OMMI SQUARE PLAQUE 4-WAY SUPPLY SURFACE STEEL 12 x 12 1

E TITUS 50F EGGCRATE GRILLE - RETURN/EXHAUST LAY-IN ALUMINUM 24 x 24 1,2

F TITUS 50F EGGCRATE GRILLE - RETURN/EXHAUST LAY-IN ALUMINUM 12 x 12 1,2

G TITUS 50F EGGCRATE GRILLE - EXHAUST SURFACE ALUMINUM 12 x 12 1

H TITUS 350RL SIDEWALL GRILLE SINGLE TRANSFER SIDEWALL STEEL 12x6 1

I TITUS S300F ROUND DUCT MOUNTED GRILL DOUBLE SUPPLY ROUND DUCT ALUMINUM 10 x 6 3

J TITUS SG-3300RL SECURITY GRILLE - TRANSFER SIDEWALL STEEL 12 x 6 1,4

K TITUS MSSG SECURITY GRILLE - EXHAUST SURFACE STEEL 12 x 12 1,5

L TITUS 350RL SIDEWALL GRILLE SINGLE TRANSFER DUCT STEEL 10x10 1

OPTIONS:1. STANDARD WHITE FINISH2. ACOUSTICALLY LINED DUCTED PLENUM BOX OVER GRILLE3. AIR SCOOP4. SECURITY GRILLE WITH MINIMUM 14 GAUGE STEEL CONSTRUCTION AND BARS SPACED ON 6" CENTERS5. ½" STEEL SECURITY BARS ON INTERIOR WITH 6" SPACING6. INCLUDE RADIATION DAMPER EQUAL TO GREENHECK WC-67. THERMALLY INSULATED FOR FIRE RATED SURFACE

ENERGY RECOVERY VENTILATOR SCHEDULE

TAG MANUFACTURER MODEL MOUNTVENTILATION FAN EXHAUST FAN NOMINAL TEMP

RECOVERYASSOCIATED FC UNITS

ELECTRICAL WEIGHT(LBS)

OPTIONSCFM ESP (IN. W.C.) CFM ESP (in. wg.) VOLTAGE PHASE MCA MOCP

ERV-1 MITSUBISHI LGH-F600 SUSPENDED 600 0.56 500 0.56 67% FC-1,2,5,7,8,13,14,16,19, 208 1 3.6 15 132

ERV-2 MITSUBISHI LGH-F600 SUSPENDED 600 0.56 500 0.56 67% FC-3,4,9,11,12,15,17,18 208 1 3.6 15 132

COMPUTER ROOM AC UNIT SCHEDULE

TAG MANUFACTURER MODEL MOUNT FAN CFMCOOLING PERFORMANCE ELECTRICAL

OPTIONSENT. AIR D.B. (°F) ENT. AIR W.B. (°F) TOTAL CAP (BTUh) SENSIBLE CAP (BTUh) VOLTAGE PHASE NOMMINAL KW

CRAC-1 DATA AIRE GTAU-018 FLOOR 2,500 80 67 65.9 54.8 208 3 18.0 ALL

OPTIONS:1. ELECTRIC STEAM GENERATOR HUMIDIFIER2. INCLUDE DISCONNECT SWITCH3. COOLING ONLY THERMOSTAT4. INSTALL ASSOCIATED OUTDOOR CONDENSER (OCU-01) DARC-07 FROM DATA AIRE MANUFACTURER. ELECTRICAL: 208/1/60 MCA-5.8 MOCP-155. SHUNT TRIP PROVIDED BY ELECTRICAL FOR EMERGENCY SHUT DOWN INTERLOCKED WITH FM200 FIRE SUPPRESSION SYSTEM (SEE FIRE PROTECTION PLAN)6. OPTIONAL TOP OR SIDE PIPING INLETS REQUIRED7. MOUNTED ON A 6" CONCRETE HOUSEKEEPING PAD

ELECTRIC WALL HEATER SCHEDULE

TAG MANUFACTURER MODEL MOUNT HEATING CAPACITY (KW)ELECTRICAL

WEIGHT (LBS) OPTIONSVOLTAGE PHASE MCA MOCP

EWH-1 QMARK AWH4408 WALL 4.0 208 1 19.2 25 30 ALL

OPTIONS:1. SURFACE MOUNTING KIT2. INTEGRAL THERMOSTAT3. FACTORY MOUNTED ELECTRICAL DISCONNECT4. STANDARD WHITE FINISH5. 1" FULL PERIMETER CLEARANCE

11/25/2019

Page 4: M:PROJECTSGBI THOMSONRevit118109 GBI THOMSON …tgmechanical.net/documents/GBI Thomson Mech Only Plans.pdf · c:\users\allend\documents\118109 gbi thomson investigative office_allendyke.rvt

SA

RA

EA

OA

SUPPLY AIR

RETURN AIR

EXHAUST AIR

OUTSIDE AIR

C CONDENSATE

PIPING SYSTEMS

DUCT SYSTEMS

MECHANICAL LEGEND

ABBREVIATIONS

DUCT TYPES

12"x12"

12"ø

RECTANGULAR

ROUND

A.F.F.CO(E)

SYMBOLST

M

WALL MOUNTED THERMOSTAT

MOTOR STARTER

KEYNOTE TAG

AIRFLOW SYMBOL

ABOVE FINISHED FLOORCLEANOUTEXISTING

#

PWALL MOUNTED CONTROL PANEL

A 12"x12"100

TYPE

NECK SIZE

CFM

AIR DEVICE TAGS

FIRE DAMPER

MOTORMEND PLUGCLEANOUT

BARB ADAPTOR WITHSTEEL BANDINGCLAMPS

TYPE "M" COPPER PIPE WITH DWV FITTINGS

TO NEAREST DRAIN

CLEAR VINYL TUBING(3'-0" MAXIMUM)

CONDENSATE PUMP CONNECTION

FAN COIL

NOTE: CONTRACTOR SHALL REFERENCEFINAL EQUIPMENT MANUFACTURERINSTALLATION INSTRUCTIONS FORFINAL DIMENSIONS AND PLACEMENTREQUIREMENTS.

ALL-THREAD ROD AT EACH CORNER OF UNIT.

EXTEND GRID TO EDGE OF UNIT CASING.

CEILING CASSETTE GRILLE.

CUT L-SHAPED PIECES OF TILE TO FILL VOID AROUND UNIT. TILES WILL BE SUPPORTED BY THE UNIT'S GRILLE. NEATLY TRIM DROP TILE TO BE FLUSH WITH UNIT'S GRILLE.

GRADE

½" TO 2" BEVEL ON EDGES#3 REINFORCING RODS 8" ON CENTER BOTH WAYS

CONCRETE6"

(PAD EXTENTS TO BE AS SHOWN AND/OR 6" MIN. LARGER THAN UNIT ON OPEN SIDES AND EXTENDED TO BUILDING EXTERIOR WALL, WHERE ADJACENT)

2" MIN.

1½" MIN.

FLEXIBLE CONNECTION

FLEXIBLE CONNECTION

SPRING VIBRATION ISOLATION MOUNTS

FAN COIL UNIT

GALVANIZED STEEL EMERGENCY DRAIN PAN WITH FLOAT SWITCH TO SHUTDOWN FAN UPON ACTIVATION

CONSTRUCT RAISED PLATFORM OF 2x4 LUMBER. MINIMUM HEIGHT 1'-0" A.F.F. OF MEZZANINE.

MOUNT UNIT SO HEIGHT OF CONDENSATE DRAIN HAS ADEQUATE SLOPE FOR DRAINAGE TO MEZZANINE FLOOR DRAIN.

NEOPRENE PADS ALL CORNERS

MECH. PLATFORM

½" PLYWOOD

PROVIDE ¼" TO ½" CLEARANCE BETWEEN WALL AND SLEEVE FOR EXPANSION

USE BREAKAWAY JOINTS AT CONNECTION OF DUCT & SLEEVE (TYP)

1½ x 1½ x 12 GA. GALV. RETAINING ANGEL BOTH SIDES OF WALL AND ALL FOUR SIDES OF SLEEVE - SECURE TO SLEEVE ONLY WITH NO. TO SHEET MTL. SCREWS 6" ON CENTER (MAX.)

24 GA. (MIN.) GALV. FIRE DAMPER SLEEVE

FIR

E

DA

MP

ER

AC

CES

S

DO

OR

HAND TIGHT PLUG

WATER SEAL

LINE SIZE OF CONDENSATE CONNECTION ON UNIT

SLOPE TO DRAINH

H = FAN INLET PRESSURE (IN. W.C.) + 1 INCH

H/2 MIN.

FROM COIL PAN

EGG CRATE RETURN GRILLE WITH BORDER, FRAME & 22"x22" NECK

LAY-IN CEILING

ACCOUSTICALLY LINED PLENUM

RETURN/EXHAUST PLENUM

UNISTRUT CHANNEL SUPPORT WITH PIPE CLAMPS, CHANNEL SUPPORTS SPACED 4' APART ALONG LENGTH OF PIPE.

WEATHER STRIPPING

PIPING WITH 2" INSULATION 16GA EPOXY PAINT OR POWDER COATED ALUMINUM COVER COLOR TO MATCH BUILDING EXTERIOR COLOR. COVER SHALL ME WEATHER TIGHT AND ENCLOSED ON ALL SIDES, TOP AND BOTTOM. BREAK EDGE ON METAL TO ALLOW FOR MOUNTING TO WALL AND WEATHERPROOFING.

1/4" HEX HEAD TAPCON WITH WASHER AT 12" ON CENTER (TYP)

EXTERIOR WALL

LEGEND

W = WIDTHH = HEIGHTD = DIAMETERV.D. = MANUAL VOLUME DAMPER WITH STANDOFF

VERTICAL SUPPLY DUCT

WxH

VDVD

VD

VD

VDVD

WxH

CROWN 3300-DSOR EQUAL

90° ELBOW WITH DOUBLE THICKNESS TURNING VANES

4'-0"

MA

XIM

UM

FLEXIBLE DUCT. PROVIDE SHEET METAL FITTINGS FOR ALL CHANGES OF DIRECTION.

CROWN 314-DSOOR EQUAL

BULLHEAD TEE WITH TURNING VANES PER SMACNA

FLANGE (2 ½")

20 GAUGE SLEEVE

BIRDSCREEN

16" MIN.

LOUVER

SEAL WITH WEATHERPROOF SEALANT AROUND FLANGE

FLANGE (2 ½")

SUB FRAME

REFER TO ARCHITECTURAL FOR WALL CONSTRUCTION

SHEET NO:

FILE NO:

PROJECT NO:

APPROVED:

DRAWN:

SCALE:

ISSUE:

DATE:

SHEET TITLE:

PROJECT TITLE:

ARCHITECT:

SEAL:

CONSULTANT:

# DATE:

AS SHOWN

2019 McCALL & ASSOCIATES, INC.C

1 72 3 4 5 6

1 72 3 4 5 6

A

B

E

C

D

A

B

E

C

D

Physical Address:3308 Country Club Rd.

Valdosta, GA 31605

Mailing Address:P.O. Box 5146

Valdosta, GA 31603Phone: 229.242.2551

Fax: 229.244.8358

www.mccallinc.com

These Contract Documents are the exclusive property of McCall and Associates, Inc. Any reproduction, modidication, disclosure and/ or use of these materials ( or any portion of them) without McCall and Associstes, Inc. prior written consent is strictly prohibited.

NAME:

4/3/2020 4:29:52 PM

Q:\

127 -

The M

cC

all

Com

panie

s\1

27-1

903 -

GB

I T

hom

son\M

EC

H\M

EC

H.r

vt

M002

118109

118109 M002

SAP

JKF

CONSTRUCTION DOCUMENTS

NOVEMBER 25, 2019

MECHANICAL DETAILS

GBI - 059 THOMSONINVESTIGATIVE OFFICE

THOMSON, GA

NOT TO SCALEM002

1 CASSETTE COIL CONDENSATE PIPE

NOT TO SCALEM002

4 CEILING CASSETTE AHU TILENOT TO SCALEM002

3 EXTERIOR CONCRETE PADNOT TO SCALEM002

5 FAN COIL ON MEZZANINE

NOT TO SCALEM002

7 FIRE DAMPER & SLEEVENOT TO SCALEM002

8 NEGATIVE PRESSURE CONDENSATE DRAIN TRAPNOT TO SCALEM002

9 RETURN/EXHAUST GRILLENOT TO SCALEM002

10 SECTION - EXTERIOR PIPE CHASE

NOT TO SCALEM002

2 TYPICAL SUPPLY OR RETURN DUCT DETAIL

NOT TO SCALEM002

6 WALL-MOUNTED FLANGED LOUVER WITH PLENUM

11/25/2019

Page 5: M:PROJECTSGBI THOMSONRevit118109 GBI THOMSON …tgmechanical.net/documents/GBI Thomson Mech Only Plans.pdf · c:\users\allend\documents\118109 gbi thomson investigative office_allendyke.rvt

RE

F.

1

2

3

4

5

6

A B C D E F G H

4.4

4.6

TOILET

123

INVESTIGATOR

125

INVESTIGATOR

126

INVESTIGATOR

121

POLYGRAPH OFFICE

119

INVESTIGATOR

120

CONFERENCE

122

INVESTIGATOR

106

INVESTIGATOR

107

EVIDENCE VAULT

129

DRUG INVESTIGATOR

142

DRUG INVESTIGATOR

141

DRUG INVESTIGATOR

140

DRUG INVESTIGATOR

139

GUN/DRUG VAULT

128

TOILET

136

MEN

130

INTERVIEW

124

MECHANICAL

109

INVESTIGATOR

108

JANITOR

145

INV

ES

TIG

AT

OR

113

INV

ES

TIG

AT

OR

115

INV

ES

TIG

AT

OR

117

INVESTIGATOR

110

WIRE TAP

134

GYM

133

CORRIDOR

135

AD

MIN

. A

SS

IST

AN

T

101

LOBBY

100

FIL

E R

OO

M

102

SU

PP

LIE

S

103

ASST. SPECIAL AGENT

IN CHARGE

104

SPECIAL AGENT IN

CHARGE

105

INV

ES

TIG

AT

OR

112

INV

ES

TIG

AT

OR

114

INV

ES

TIG

AT

OR

116

SALLY PORT

147

BREAK ROOM

146

STORAGE

144

ELECTRICAL / UTILITY

111

CORRIDOR

131

WOMEN

132POLYGRAPH

118

CORRIDOR

127

CONFERENCE

137

ASST. SPECIAL AGENT

IN CHARGE

138

MDF

143

FC-1 FC-2 FC-3 FC-4

FC-5

FC-7

FC-11FC-12

FC-9

FC-8

8"øB

85

8"øA

200

8"øA

200

6"øA

100

8"øC

120

8"øA

250

8"øA

250

8"øC

120

22"x22"E

370

22"x22"E

100

22"x22"E

415

22"x22"E

145

22"x22"E

145

22"x22"E

145

22"x22"E

145

8"øA

180

8"øA

180

8"øA

180

8"øA

180

8"øA

150

8"øA

150

8"øA

150

8"øA

150

8"øA

150

8"øA

150

8"øA

100

6"øA

100

6"øA

100

8"øA

150

22"x22"E

100

8"øA

200

8"øA

200

22"x22"E

100

22"x22"E

130

22"x22"E

300

6"øD

50

6"øA

50

22"x22"E

1008"øA

130

8"øA

130

8"øA

130

8"øA

130

22"x22"E

110

22"x22"E

110

22"x22"E

110

22"x22"E

110

6"øA

70

6"øA

906"øA

906"øA

40

6"øA

90

6"øA

90

11"x11"F

75

11"x11"G

75

22"x22"E

230

HP-2

22"x22"E

130

22"x22"E

130

22"x22"E

130

22"x22"E

130

22"x22"E

130

22"x22"E

130

22"x22"E

100

22"x22"E

75

22"x22"E

75

22"x22"E

20

22"x22"E

75

22"x22"E

75

22"x22"E

70

HP-1

22"x22"E

85

11"x11"F

75

11"x11"G

150

11"x11"G

150

11"x11"G

100

11"x11"G

100

1 1 1

FREE

11"x5"J

2

FREE

12"x6"HFREE

12"x6"H

3

11"x11"K

1004

T T T T T

T

T

T

T

TT

T

T

T

T

T

T

5

6"ø

OA

8"ø OA 4"ø OA

8"ø

RA

8"x

10"

SA

12"x12" RA

8"ø

SA

8"ø RA

12"x12" SA

8"x10" SA

8"ø

SA

8"x

10"

RA

8"ø RA

10"ø RA

12"x

14"

RA

8"ø RA

8"ø SA8"x8" SA

8"ø EA

8"ø

EA

8"ø EA

10"ø EA

10"x

10"

EA

12"x

12"

SA

10"x

10"

SA

10"x

10"

SA

10"x12" SA6"ø

RA

12"x10" RA

8"ø EA

12"x

10"

EA

8"ø EA

8"ø EA

8"ø EA

8"ø

RA10"x10" RA

8"ø SA

8"x

10"

SA

10"x

12"

SA

12"x

14"

SA 12"x10" RA

12"x

14"

RA

8"ø RA

10"x10" RA

10"x12" SA

10"x10" RA

8"x10" SA

8"ø

RA

8"ø

RA

8"ø

RA

6"x

10"

SA

8"x

10"

RA

8"ø RA

8"ø

RA

8"ø

RA

1 1

1

1

1

8"x10" RA

8"ø

SA

8"ø

RA

8"x

10"

SA

12"x

10"

RA 12"x10" SA

8"x

10"

SA

8"ø RA

8"ø RA

8"ø

RA

8"ø

SA

8"ø RA

8"ø

SA

6"ø

RA

12"x10" RA

4"ø OA

6"ø

OA

4"ø OA

6"ø SA

8"ø

RA

8"ø

RA

12"x14" RA

10"x10" SA

12"x

14"

SA 10"x10" SA

12"x

14"

RA

8"ø

RA

10"ø

RA

8"ø RA

1

1

10"x

10"

SA

MEZZANINE BOUNDARY

MEZZANINE BOUNDARY

ME

ZZ

AN

INE

BO

UN

DA

RY

1

1

8"ø

RA

6"ø OA

6"x

10"

SA

8"x10" SA

12"x10" SA

8"x10" RA

10"x10" RA

5

M103

P6

7

CRAC-1

3' - 4"

3' -

0"

3' -

0"

OCU-1

FREE

22"x22"E

FREE

11"x11"G8

8"x

8"

RA

EF-3

INSTALL BELOW CEILING FOR ACCESSIBILITY

8"x8" EA

9

810"x10"L

200

1'-0" A.F.F.

M

M

EWH-1

SHEET NO:

FILE NO:

PROJECT NO:

APPROVED:

DRAWN:

SCALE:

ISSUE:

DATE:

SHEET TITLE:

PROJECT TITLE:

ARCHITECT:

SEAL:

CONSULTANT:

# DATE:

AS SHOWN

2019 McCALL & ASSOCIATES, INC.C

1 72 3 4 5 6

1 72 3 4 5 6

A

B

E

C

D

A

B

E

C

D

Physical Address:3308 Country Club Rd.

Valdosta, GA 31605

Mailing Address:P.O. Box 5146

Valdosta, GA 31603Phone: 229.242.2551

Fax: 229.244.8358

www.mccallinc.com

These Contract Documents are the exclusive property of McCall and Associates, Inc. Any reproduction, modidication, disclosure and/ or use of these materials ( or any portion of them) without McCall and Associstes, Inc. prior written consent is strictly prohibited.

NAME:

4/3/2020 4:29:57 PM

Q:\

127 -

The M

cC

all

Com

panie

s\1

27-1

903 -

GB

I T

hom

son\M

EC

H\M

EC

H.r

vt

M101

118109

118109 M101

SAP

JKF

CONSTRUCTION DOCUMENTS

NOVEMBER 25, 2019

MECHANICAL - OFFICEBUILDING

GBI - 059 THOMSONINVESTIGATIVE OFFICE

THOMSON, GA

NO

RT

H

3/16" = 1'-0"M101

1 HVAC PLAN - OFFICE BUILDING

GENERAL NOTES: (THIS SHEET ONLY)

KEYNOTES: (THIS SHEET ONLY)

DUCT RISE TO PROVIDE 8'-0" CLEARANCE ABOVE MEZZANINE WHERE POSSIBLE. SEE MECHANICAL MEZZANINE PLAN.

INSTALL TOP OF TRANSFER SECURITY GRILLE 1'-0" BELOW CEILING. DUCT THROUGH WALL AND INSTALL FIRE DAMPER ON INTERIOR SIDE OF VAULT.

INSTALL TOP OF TRANSFER GRILLE 1'-0" BELOW CEILING.

DUCT THROUGH MEZZANINE WITH FIRE DAMPER. INSTALL ½" SECURITY BARS SPACED 6" ON CENTERS AT PENETRATION.

HARD DUCTED TO AIR DEVICE. THERMALLY INSULATED WITH RADIATION DAMPER.

ALL UNITS CONNECTED TO CENTRAL CONTROLLER MITSUBISHI AE-200A

POURED-IN-PLACE CONCRETE EQUIPMENT PAD. SIZED TO EXTEND TO EXTERIOR WALL AND SIDEWALK AND 4" LARGER THAN FOOTPRINT OF EQUIPMENT. INCLUDE FLEX JOINT BETWEEN UNIT AND BUILDING. MECHANICAL EQUIPMENT INSTALLED WITH CLEARANCES PER MANUFACTURER'S IOM.

MOTORIZED DAMPER INTERLOCKED WITH FM200 SYSTEM (SEE FIRE PROTECTION). OPEN ONLY DURING PURGE CYCLE. DAMPER SHALL MEET UL # 5555 MINIMUM 5% LEAKAGE. ACTUATOR 120V FAST-ACTING.

TERMINATE EXHAUST WITH HOODED WALL CAP WITH BIRDSCREEN AND BACKDRAFT DAMPER EQUAL TO GREENHECK WC-8

1

2

3

4

5

1. BRANCH DUCT SIZE IS EQUAL TO AIR DEVICE NECK SIZE UNLESS OTHERWISE NOTED.

2. COORDINATE ALL EQUIPMENT INSTALLATION FINAL LOCATIONS TO ALLOW FOR SUFFICIENT MAINTENANCE ACCESS.

6

7

8

9

11/25/2019

Page 6: M:PROJECTSGBI THOMSONRevit118109 GBI THOMSON …tgmechanical.net/documents/GBI Thomson Mech Only Plans.pdf · c:\users\allend\documents\118109 gbi thomson investigative office_allendyke.rvt

1

2

3

4

5

6

A B C D E F G H

4.4

4.6

FC-16

FC

-15

FC

-14

FC

-13

FC-19

FC-18

FC

-17

BC

-1

BC

-2

EF-1

LV-1 LV-2

FC-6 ERV-1 FC-20

ERV-2

5

M103

MECHANICAL MEZZANINE

1

1

16"x14" EA

8"ø EA

16"x14" EA

8"ø

RA

8"ø

SA

6"x

10"

SA

8"x

10"

RA

2

22 2

22 2

2

2

2

2

2

2

2

12"x

14"

RA

12"x

14"

SA

10"x

12"

SA

12"x10" RA

8"ø

OA

6"ø

OA

10"x10" RA

8"x

10"

SA

12"x

10"

SA

6"ø

OA

8"ø

OA

12"x12" OA

6"ø

OA

6"ø

OA

12"x10" RA

6"ø

OA

12"x14" SA

12"x

14"

RA

8"ø

OA

12"x12" OA

12"x

10"

EA

10"ø EA

10"ø

OA

10"ø

OA

10"ø

EA

10"ø

EA

10"x10" EA

12"x10" EA

8"ø

EA

12"x12" OA

8"ø

OA

12"x12" OA

12"x12" SA

12"x

14"

RA

12"x

12"

SA

12"x12" RA

10"ø

OA

16"x14" OA 16"x14" OA

3

M103

33

4

M103

BOTTOM OF LOUVER AT 18'-6" A.F.F.

BOTTOM OF LOUVER AT 18'-6" A.F.F.

3

3 3

3

3

3

SHEET NO:

FILE NO:

PROJECT NO:

APPROVED:

DRAWN:

SCALE:

ISSUE:

DATE:

SHEET TITLE:

PROJECT TITLE:

ARCHITECT:

SEAL:

CONSULTANT:

# DATE:

AS SHOWN

2019 McCALL & ASSOCIATES, INC.C

1 72 3 4 5 6

1 72 3 4 5 6

A

B

E

C

D

A

B

E

C

D

Physical Address:3308 Country Club Rd.

Valdosta, GA 31605

Mailing Address:P.O. Box 5146

Valdosta, GA 31603Phone: 229.242.2551

Fax: 229.244.8358

www.mccallinc.com

These Contract Documents are the exclusive property of McCall and Associates, Inc. Any reproduction, modidication, disclosure and/ or use of these materials ( or any portion of them) without McCall and Associstes, Inc. prior written consent is strictly prohibited.

NAME:

4/3/2020 4:29:58 PM

Q:\

127 -

The M

cC

all

Com

panie

s\1

27-1

903 -

GB

I T

hom

son\M

EC

H\M

EC

H.r

vt

M102

118109

118109 M102

SAP

JKF

CONSTRUCTION DOCUMENTS

NOVEMBER 25, 2019

MECHANICAL - MEZZANINELEVEL

GBI - 059 THOMSONINVESTIGATIVE OFFICE

THOMSON, GA

NO

RT

H

3/16" = 1'-0"M102

1 HVAC PLAN - MEZZANINE

GENERAL NOTES: (THIS SHEET ONLY)

KEYNOTES: (THIS SHEET ONLY)

VENTILATION DUCT INTO FAN COIL RETURN PLENUM

DUCT DOWN. SEE MECHANICAL OFFICE BUILDING PLAN.

UNIT TO BE SUSPENDED FROM STRUCTURE ABOVE WITH ALL-THREAD RODS AND VIBRATION ISOLATORS.

1

2

1. BRANCH DUCT SIZE IS EQUAL TO AIR DEVICE NECK SIZE UNLESS OTHERWISE NOTED.

2. COORDINATE ALL EQUIPMENT INSTALLATION FINAL LOCATIONS TO ALLOW FOR SUFFICIENT MAINTENANCE ACCESS.

3

11/25/2019

Page 7: M:PROJECTSGBI THOMSONRevit118109 GBI THOMSON …tgmechanical.net/documents/GBI Thomson Mech Only Plans.pdf · c:\users\allend\documents\118109 gbi thomson investigative office_allendyke.rvt

MEZZANINE10' - 8"

CEILING9' - 4"

MIN

8' C

LE

AR

AN

CE

8"ø

SA

8"ø RA

HP-1

HP-2

FC-13FC-19

FC-9

FC-14

FC-15

FC-16FC-6

BC-1

ERV-1

ERV-2

FC-20

BC-2

FC-3

FC-4

FC-18

FC-17

FC-1

FC-2

FC-5

OCU-1

CRAC-1

EF-3

FIRST FLOOR0' - 0"

MEZZANINE10' - 8"

CEILING9' - 4"

FC-14 FC-15

FC-7

16"x14" EA8"x6" EA

12"x12" OA

6"ø OA

8"ø OA

6"ø OA

EF-1

BACKDRAFT DAMPER

MVDTYPICAL MVD

TYPICAL

SEE DETAIL FOR HORIZONTAL FAN COIL ON MECHANICAL PLATFORM

FIRST FLOOR0' - 0"

MEZZANINE10' - 8"

CEILING9' - 4"

FC-20 ERV-2 ERV-1 FC-6

BC-1

12"x12" OA

12"x

10"

EA

10"x

10"

EA

12"x12" OA

10"ø EA

12"x12" OA

14"x16" EA14"x16" OA

8"ø EA 8"ø EA

FREE

12"x6"H

FREE

12"x6"H

8"ø SA

GUN/DRUG VAULT

FC-20

ERV-2

ERV-1

FC-6

12"x12" OA

12"x12" OA

10"ø EA

10"ø

EA

16"x14" EA

16"x14" OA10"x10" EA

12"x12" OA

10"ø

OA

MECHANICAL MEZZANINE

BC-1

SHEET NO:

FILE NO:

PROJECT NO:

APPROVED:

DRAWN:

SCALE:

ISSUE:

DATE:

SHEET TITLE:

PROJECT TITLE:

ARCHITECT:

SEAL:

CONSULTANT:

# DATE:

AS SHOWN

2019 McCALL & ASSOCIATES, INC.C

1 72 3 4 5 6

1 72 3 4 5 6

A

B

E

C

D

A

B

E

C

D

Physical Address:3308 Country Club Rd.

Valdosta, GA 31605

Mailing Address:P.O. Box 5146

Valdosta, GA 31603Phone: 229.242.2551

Fax: 229.244.8358

www.mccallinc.com

These Contract Documents are the exclusive property of McCall and Associates, Inc. Any reproduction, modidication, disclosure and/ or use of these materials ( or any portion of them) without McCall and Associstes, Inc. prior written consent is strictly prohibited.

NAME:

4/3/2020 4:30:03 PM

Q:\

127 -

The M

cC

all

Com

panie

s\1

27-1

903 -

GB

I T

hom

son\M

EC

H\M

EC

H.r

vt

M103

118109

118109 M103

SAP

JKF

CONSTRUCTION DOCUMENTS

NOVEMBER 25, 2019

MECHANICAL - DETAILVIEWS

GBI - 059 THOMSONINVESTIGATIVE OFFICE

THOMSON, GA

NOT TO SCALEM103

5 MEZZANINE DUCT CLEARANCE

NOT TO SCALEM103

1 OFFICE BUILDING OVERALL

NOT TO SCALEM103

3 MEZZANINE SECTION 1NOT TO SCALEM103

4 MEZZANINE SECTION 2

NOT TO SCALEM103

2 MEZZANINE VENTILATION UNITS

11/25/2019

Page 8: M:PROJECTSGBI THOMSONRevit118109 GBI THOMSON …tgmechanical.net/documents/GBI Thomson Mech Only Plans.pdf · c:\users\allend\documents\118109 gbi thomson investigative office_allendyke.rvt

RE

F.

G1

G2

G3

G4

GA GB GC

BOMB TRUCK GARAGE

G101

PROCESSING BAY

G100

FC-21

HP-3

EF-2

1

5

2

3

4

5

6

A B C D E F G H

4.4

4.6

TOILET

123

INVESTIGATOR

125

INVESTIGATOR

126

INVESTIGATOR

121 POLYGRAPH OFFICE

119

INVESTIGATOR

120

CONFERENCE

122

INVESTIGATOR

106

INVESTIGATOR

107

EVIDENCE VAULT

129

DRUG INVESTIGATOR

142

DRUG INVESTIGATOR

141

DRUG INVESTIGATOR

140

DRUG INVESTIGATOR

139

TOILET

136

MEN

130

MECHANICAL

109

INVESTIGATOR

108

JANITOR

145INVESTIGATOR

113INVESTIGATOR

115INVESTIGATOR

117

INVESTIGATOR

110

GYM

133

CORRIDOR

135

ADMIN. ASSISTANT

101

LOBBY

100FILE ROOM

102SUPPLIES

103

ASST. SPECIAL AGENT

IN CHARGE

104

SPECIAL AGENT IN

CHARGE

105

INVESTIGATOR

112INVESTIGATOR

114INVESTIGATOR

116SALLY PORT

147

BREAK ROOM

146STORAGE

144ELECTRICAL / UTILITY

111

CORRIDOR

131

WOMEN

132

CORRIDOR

127

CONFERENCE

137

ASST. SPECIAL AGENT

IN CHARGE

138

MDF

143

FC-1 FC-2

FC-5

FC-3

FC-7

FC-8

FC-11FC-12

FC-9

HP-2

BC

-1

HP-1

BC-2

FC-6 FC-20ERV-1

ERV-2

MEZZANINE BOUNDARY

MEZZANINE BOUNDARY

ME

ZZ

AN

INE

BO

UN

DA

RY

CO

COCO

1

FC-4

CO

CO CO

1

2" C 2" C2" C 2" C

FC

-14

FC

-15

FC-16

FC-19

FC

-13

FC-18

FC

-17

2

2

2

3

2 1/2" C 2" C

2" C

2"

C

2" C

2" C

2" C

EF-1

4 4

4

4

4

4

CO

CO

CO

CO

CO CO

CO

5

P

6

CRAC-1

OCU-1

SHEET NO:

FILE NO:

PROJECT NO:

APPROVED:

DRAWN:

SCALE:

ISSUE:

DATE:

SHEET TITLE:

PROJECT TITLE:

ARCHITECT:

SEAL:

CONSULTANT:

# DATE:

AS SHOWN

2019 McCALL & ASSOCIATES, INC.C

1 72 3 4 5 6

1 72 3 4 5 6

A

B

E

C

D

A

B

E

C

D

Physical Address:3308 Country Club Rd.

Valdosta, GA 31605

Mailing Address:P.O. Box 5146

Valdosta, GA 31603Phone: 229.242.2551

Fax: 229.244.8358

www.mccallinc.com

These Contract Documents are the exclusive property of McCall and Associates, Inc. Any reproduction, modidication, disclosure and/ or use of these materials ( or any portion of them) without McCall and Associstes, Inc. prior written consent is strictly prohibited.

NAME:

4/3/2020 4:30:06 PM

Q:\

127 -

The M

cC

all

Com

panie

s\1

27-1

903 -

GB

I T

hom

son\M

EC

H\M

EC

H.r

vt

M104

118109

118109 M104

SAP

JKF

CONSTRUCTION DOCUMENTS

NOVEMBER 25, 2019

MECHANICAL -CONDENSATE AND

REFRIGERANT

GBI - 059 THOMSONINVESTIGATIVE OFFICE

THOMSON, GA

NO

RT

H

1/8" = 1'-0"M104

2 GARAGE CONDENSATE AND REFRIGERANT

NO

RT

H

1/8" = 1'-0"M104

1 OFFICE BUILDING CONDENSATE AND REFRIGERANT

GENERAL NOTES: (THIS SHEET ONLY)

KEYNOTES: (THIS SHEET ONLY)

ROUTE CONDENSATE PIPING WITH ½" ARMAFLEX INSULATION DOWN EXTERIOR WALL, CONCEALED IN CMU WALL CAVITY OR AIR SPACE, AND TERMINATE TO THE EXTERIOR WITH 90° ELBOW, ABOVE CONCRETE SPLASH BLOCK INSTALLED OVER FINISHED GRADE. PAINT ANY EXPOSED PVC TO MATCH WALL

ROUTE CONDENSATE TO MEZZANINE FLOOR DRAIN. REFER TO PLUMBING. COORDINATE SLOPE AND ROUTING WITH ALL TRADES

ROUTE CONDENSATE DRAIN LINE TO JANITOR'S MOP BASIN AS SHOWN. COORDINATE SLOPE AND ROUTING WITH ALL TRADES

REFER TO CONDENSATE DRAIN CONNECTION DETAIL #1 / M002

REFER TO DETAIL #10 / M002 FOR EXTERIOR REFRIGERANT ROUTING.

ALL OFFICE BUILDING UNITS CONNECTED TO CENTRAL CONTROLLER MITSUBISHI AE-200A

1

2

3

4

5

1. REFRIGERANT AND CONDENSATE DRAIN PIPING SHALL BE INSULATED WITH ELASTOMERIC FOAM

2. REFRIGERANT LINE SETS ON THIS SHEET ARE REPRESENTED FOR SCHEMATIC PURPOSES ONLY. COORDINATE ACTUAL ROUTES IN FIELD FOR EFFICIENCY AND ACCESSIBILITY.

3. GROUP REFRIGERANT HEADERS AND JOINTS FOR COMMON ACCESS AND MAINTENANCE WHERE POSSIBLE. LABEL ALL WITH PARENT HEAT PUMP.

6

11/25/2019

Page 9: M:PROJECTSGBI THOMSONRevit118109 GBI THOMSON …tgmechanical.net/documents/GBI Thomson Mech Only Plans.pdf · c:\users\allend\documents\118109 gbi thomson investigative office_allendyke.rvt

G1

G2

G3

G4

GA GB GC

BOMB TRUCK GARAGE

G101

PROCESSING BAY

G100

FC-21

HP-3

1

2

3

EF-2

1 4

7

LV-3

M

M4

4

5

C

10"x6"I

250

10"x6"I

250

10"x6"I

250

10"x6"I

250

10"x6"I

200

10"x6"I

200

T

8

16"x

16"

RA

6"ø

OA

16"ø SA

3

M201

EF-2

FC-21

HP-3

LV-3

TM

C

FIRST FLOOR0' - 0"

EF-2

16"ø SA FC-21

HP-3

LV-3

16"x16" RA

SHEET NO:

FILE NO:

PROJECT NO:

APPROVED:

DRAWN:

SCALE:

ISSUE:

DATE:

SHEET TITLE:

PROJECT TITLE:

ARCHITECT:

SEAL:

CONSULTANT:

# DATE:

AS SHOWN

2019 McCALL & ASSOCIATES, INC.C

1 72 3 4 5 6

1 72 3 4 5 6

A

B

E

C

D

A

B

E

C

D

Physical Address:3308 Country Club Rd.

Valdosta, GA 31605

Mailing Address:P.O. Box 5146

Valdosta, GA 31603Phone: 229.242.2551

Fax: 229.244.8358

www.mccallinc.com

These Contract Documents are the exclusive property of McCall and Associates, Inc. Any reproduction, modidication, disclosure and/ or use of these materials ( or any portion of them) without McCall and Associstes, Inc. prior written consent is strictly prohibited.

NAME:

4/3/2020 4:30:08 PM

Q:\

127 -

The M

cC

all

Com

panie

s\1

27-1

903 -

GB

I T

hom

son\M

EC

H\M

EC

H.r

vt

M201

118109

118109 M201

SAP

JKF

CONSTRUCTION DOCUMENTS

NOVEMBER 25, 2019

MECHANICAL - EVIDENCEGARAGE

GBI - 059 THOMSONINVESTIGATIVE OFFICE

THOMSON, GA

GENERAL NOTES: (THIS SHEET ONLY)

NO

RT

H

3/16" = 1'-0"M201

1 HVAC PLAN - EVIDENCE GARAGE

NOT TO SCALEM201

2 GARAGE OVERALL

KEYNOTES: (THIS SHEET ONLY)

COVER OPEN END WITH HARDWARE CLOTH

TERMINATE INTAKE WITH WALL CAP AND INSECT SCREEN

TOP OF UNIT MOUNTED AT 15'-0" A.F.F.

ANY EXPOSED WIRING SHALL BE IN RIGID CONDUIT. REFER TO ELECTRICAL SPECIFICATIONS FOR CONDUIT REQUIREMENTS.

LOUVER MOUNTED IN EXTERIOR WALL PER MANUFACTURER, METAL BUILDING MANUFACTURER AND ARCHITECTURAL SPECIFICATIONS TO MAKE PENETRATION WATER-TIGHT; BOTTOM OF LOUVER INSTALLED 1' A.F.F.

MOUNT CARBON MONOXIDE DETECTOR HIGH ON WALL, OR AT MANUFACTURERS RECOMMENDED HEIGHT IN THIS LOCATION. SENSOR SHALL ENERGIZE EXHAUST FAN UPON DETECTION OF CARBON MONOXIDE

MANUAL BALANCING DAMPER

POURED-IN-PLACE CONCRETE EQUIPMENT PAD. SIZED TO EXTEND TO EXTERIOR WALL AND 4" LARGER THAN FOOTPRINT OF EQUIPMENT. INCLUDE FLEX JOINT BETWEEN UNIT AND BUILDING. MECHANICAL EQUIPMENT INSTALLED WITH CLEARANCES PER MANUFACTURER'S IOM.

1

2

3

4

5

6

7

8

NOT TO SCALEM201

3 EVIDENCE GARAGE SECTION

1. COORDINATE ALL EQUIPMENT INSTALLATION FINAL LOCATIONS TO ALLOW FOR SUFFICIENT MAINTENANCE ACCESS.