4
MAGNETIC PARICLE EXAMINATION REPORT CLIENT PROJECT JOB NO : DRAWING NO API 5L GR B CONSUMABLES MANUFACTURER TYPE / Brand CONTRAST PAINT Magna Flux WCP-2 TEST MEDIUM Magna Flux 7HF JOINT NO'S: WELD LOCATION SIZE & Thk. WELDER NO. REMARKS: The above welding locations final MPT was carried out and found satisfac CONTRACTOR CLIEN Name: Signature: ACCEPTANCE STANDARDS : ASME B31.3, ASME SECTION V Article 7 SURFACE CONDITION : As welded PROCEDURE NO : MATERIAL VIEWING CONDITION : TECHNIQUE: ASME SEC V, Art 7 Wet Spray Method DEMAGNETIZATION TYPE OF EQUIPMENT : PERMENANT MAGNET MAGNET LIFING POWER : 40 ILLUMINATION LEVEL : 1000 LUX ILLUMINATION TYPE TEMPERATURE DURING TEST : ATM. TEMP

Upload: roshan-thomas

Post on 22-Oct-2015

67 views

Category:

Documents


3 download

DESCRIPTION

Magnetic Particle Test report format.

TRANSCRIPT

Page 1: Mpt Report Format

MAGNETIC PARICLE EXAMINATION REPORT

CLIENT :

PROJECT :

JOB NO :

DRAWING NO :

API 5L GR B

CONSUMABLES MANUFACTURER TYPE / Brand Batch No

CONTRAST PAINT Magna Flux WCP-2

TEST MEDIUM Magna Flux 7HF

JOINT NO'S: WELD LOCATION SIZE & Thk. WELDER NO. RESULT

REMARKS:

The above welding locations final MPT was carried out and found satisfactory results.

CONTRACTOR CLIENT

Name:

Signature:

REPORT NO: 01

DATE:

LINE NO:

ACCEPTANCE STANDARDS : ASME B31.3, ASME SECTION V Article 7

SURFACE CONDITION : As welded PROCEDURE NO :

MATERIAL : ASTM 283 Gr. C VIEWING CONDITION : Normal

TECHNIQUE: ASME SEC V, Art 7 Wet Spray Method DEMAGNETIZATION : N/A

TYPE OF EQUIPMENT : PERMENANT MAGNET MAGNET LIFING POWER : 40 LBS ( 18 KG )

ILLUMINATION LEVEL : 1000 LUX ILLUMINATION TYPE : NATURAL / ARIFICAL

TEMPERATURE DURING TEST : ATM. TEMP

Page 2: Mpt Report Format

Date: