mpu replacement chassis - honeywell · honeywell proprietary honeywell.com 3 pov-221-110.01 mpu...

18
MPU Replacement Chassis October 2011

Upload: dangtram

Post on 08-Jan-2019

263 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

MPU Replacement Chassis

October 2011

Page 2: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

Honeywell Proprietary

Honeywell.com

2

POV-221-110.01 MPU Replacement Chassis – October 2011

Process Solutions

Legacy Measurex MPU Interface

• Measurex MPU Chassis from the

early 1980’s reached end-of-life

long ago.

– MPU was Measurex interface for

CD actuators

• ThermaTrol, AquaTrol, CalTrol,

SteamTrol

– MPU withdrawn from sale in 1992

• Replaced by Profile Managers with

GE 90/70 PLC

• Whatever parts still available

today are offered only under the

'repair exchange' procedure or a

'level 1 down' with return

afterwards.

Page 3: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

Honeywell Proprietary

Honeywell.com

3

POV-221-110.01 MPU Replacement Chassis – October 2011

Process Solutions

NEW MPU Replacement Chassis

• Digital Outputs ONLY:

– Duty cycle (ThermaTrol, CalTrol, Calcoil) or 4-bit parallel (AquaTrol)

• Standard I/O PCB: switch selectable duty cycle or 4-bit parallel

• 200-100 serial links ONLY (RS232 or FSK)

• Status feedback inputs NOT supported

• ScaniValve NOT supported

• CWS double-precision protocols NOT supported

Page 4: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

Honeywell Proprietary

Honeywell.com

4

POV-221-110.01 MPU Replacement Chassis – October 2011

Process Solutions

Scope - MPU Replacement Kit

• Drop-in replacement for the MPU Chassis assembly

– Ref: Models 2573 and 2575 interface sub-systems in Production

Release documents

– Used for ThermaTrol, CalTrol, and AquaTrol actuators.

• The kit replaces the complete MPU chassis and all PCBs

– Ribbon-cable connections and functions all compatible with the

original chassis.

– All existing power-switching electronics and terminations to the

actuators are to be retained and remain unchanged.

– Replaced components include

• MPU Chassis / Power Supply (08343800),

• MPU Processor (05365800)

• PAV interface boards (05287000).

Page 5: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

Honeywell Proprietary

Honeywell.com

5

POV-221-110.01 MPU Replacement Chassis – October 2011

Process Solutions

Success Story – Augusta Newsprint

From John Anderson (Field Service Specialist) 10/10/2011:

• The new and improved MPU upgrade kits dropped right

in. There is one card (processor) that requires some simple

configuration (a jumper and a switch). On the old MPU’s, the

Aquatrol, Thermatrol, and Caliper controls have unique processor

cards/proms. The MPU upgrade kits have cards are

interchangeable between other MPU upgrade kits, reducing the

amount of spares required.

• ….Things went great. We haven’t had any issues with them so

far – over a year.

Page 6: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

Honeywell Proprietary

Honeywell.com

6

POV-221-110.01 MPU Replacement Chassis – October 2011

Process Solutions

Scope - continued

Old MPU chassis (left) is replaced by the drop-in

replacement kit (right)

Page 7: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

Honeywell Proprietary

Honeywell.com

7

POV-221-110.01 MPU Replacement Chassis – October 2011

Process Solutions

Models 8891 & 8892

Items to order: Configuration & Quantities:

MPU Replacement Kit Chassis with Power

Supply & Processor, #09889100

Customer Sell Price: US$ $13,879.00 per set

Delivery: unforecasted lead time 22 weeks

Notes: (a) order from Vancouver ONLY. Limited

quantities on hand for prompt shipment.

Check before committing. (b) K&E Pricing

requires return of the old equipment to

Honeywell

Order qty 1 per actuator “beam” (ThermaTrol,

CalTrol, or AquaTrol)

Input voltage: 115 VAC, 50 / 60 Hz

Serial Link: RS232 or FSK

Protocol: 200-100 with 6-bit setpoints

MPU Replacement Kit Output PCB,

#09889200

Customer Sell Price: US$ $2891.00 each

Delivery: unforecasted lead time 22 weeks

* Notes: same as above

For Duty Cycle outputs to ThermaTrol, CalTrol,

Calcoil, order 1 per 32 zones (max 4 PCB)

Max number of zones per chassis: 128

Duty Cycle: 8-second time base with 125-

millisecond resolution (6-bit setpoint)

For 4-Bit Parallel outputs to AquaTrol;

order 1 per 8 zones (max 9 PCB)

Max number of zones per chassis:72

Page 8: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

Honeywell Proprietary

Honeywell.com

8

POV-221-110.01 MPU Replacement Chassis – October 2011

Process Solutions

BOM Breakdown

• Model 8891: MPU Replacement Kit Chassis with Power Supply &

Processor – List Price $13,879.00 (2011 SPM)

– Transfer Price $6999.00 (2011 SPM) – order as 09889100 includes

• Processor Card – Qty 1 Part No. : 6542800045

• Power supply module – Qty 1 Part No. : 6543140089

• Rack complete with back-plane – Qty 1 Part No. : 6543060055

• Installation Guide – Qty 1 Part No.: 6510020266

• Model 8892: MPU Replacement Kit Output PCB – List Price List $2891.00 USD (2011 SPM)

– Transfer Price: $1467.00 (2011 SPM)

– order as 09889200 includes • Digital output Card – Qty 1 Part No. : 6543140090

Page 9: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

Honeywell Proprietary

Honeywell.com

9

POV-221-110.01 MPU Replacement Chassis – October 2011

Process Solutions

MPU Replacement Chassis w/ 4 I/O PCB

• 1 x 8891 with 4 x 8892 I/O PCB’s, suitable for…

– 128-Zone ThermaTrol or CalTrol (duty cycle) OR

– 32-Zone AquaTrol (4-bit parallel)

Page 10: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

Honeywell Proprietary

Honeywell.com

10

POV-221-110.01 MPU Replacement Chassis – October 2011

Process Solutions

MPU Replacement Chassis w/ 9 I/O PCB

• 1 x 8891 with 9 x 8892 I/O PCB’s suitable for…

– 72-Zone AquaTrol (4-bit parallel)

Page 11: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

Honeywell Proprietary

Honeywell.com

11

POV-221-110.01 MPU Replacement Chassis – October 2011

Process Solutions

Product Positioning

• Intended as a service K&E

• Low-cost way to avoid downtime & frustration due to lack of

replacement parts for the MPU chassis

– Literally minutes to install; ribbon cable compatible with MPU

– No software changes; same 200-100 link

• Preserves customer investment in legacy CD actuators without

demanding a technology upgrade

– 200-100 serial link only; LAN communication not supported

– A safe investment regardless of subsequent QCS upgrades

• Experion MX and Da Vinci speak 200-100 protocol

• Technology upgrades should consider actuator replacement, or

at least a new Profile Manager for LAN connectivity

Page 12: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

Honeywell Proprietary

Honeywell.com

12

POV-221-110.01 MPU Replacement Chassis – October 2011

Process Solutions

Product Positioning

• Field proven: Trial units have been in field operation since

November 2010 without problem.

• MPU Replacement Kit must be ordered from Vancouver Service

Center.

• Limited number of kits on the shelf as of June 2011, and

available for prompt shipment. Check before making any

commitments

• Unforecasted lead time is 22 weeks

• Forecasted demand not yet established, so your inputs &

forecasts are needed to plan future inventory for fast deliveries.

• K&E Pricing requires return of the old equipment to Honeywell

Page 13: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

Honeywell Proprietary

Honeywell.com

13

POV-221-110.01 MPU Replacement Chassis – October 2011

Process Solutions

Legacy Measurex Actuators & Interfaces

• ThermaTrol I or II – End of Life

– Recommend replacing the actuator with AutoSlice CDW, otherwise:

– If UNITEC interface, replace with HC900 based Profile Manager.

– If MPU, order MPU Replacement Chassis OR new Profile Manager

with duty-cycle interface

• AquaTrol – Still current

– Current product employs similar technology (different solenoids)

– If UNITEC interface, replace with HC900 based Profile Manager.

– If MPU, order MPU Replacement Chassis OR new Profile Manager

with 4-bit parallel outputs to solenoids.

• CalTrol I or II – End of Life

– Recommend replacing with Calcoil, otherwise:

– If UNITEC interface, replace with HC900 based Profile Manager.

– If MPU, order MPU Replacement Chassis OR new Profile Manager

with duty-cycle interface

Page 14: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

Honeywell Proprietary

Honeywell.com

14

POV-221-110.01 MPU Replacement Chassis – October 2011

Process Solutions

Legacy Measurex Steambox & Interface

• SteamTrol – End of Life

– Very limited parts support; recommend replacement with Devronizer

– Note: XP10 steam actuator upgrade NOT available for SteamTrol

• ScaniValve interface - End of Life

– Unsupported

– Replace ScaniValve interface with IDP II (CDWeb)

– IDP for SteamTrol must be set up for 3-15 psi (not 6-30 psi)

• ODX, RTU Modbus, Modbus TCP, and OPC are currently supported

protocols.

• 200-100, SCL, or ABB Microset serial protocols are not supported by

CDWeb systems.

• Beware: HP or ET systems with only 200-100 links cannot use

IDP. Yet another reason to upgrade now.

Page 15: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

Honeywell Proprietary

Honeywell.com

15

POV-221-110.01 MPU Replacement Chassis – October 2011

Process Solutions

New Profile Manager - Duty Cycle I/O

• New Duty Cycle I/O systems use HC900 in Profile Manager type

enclosure.

– Used only for legacy actuators (no new actuators use duty cycle)

– Modbus TCP protocol for direct connection to Experion MX, Da Vinci.

– ODX and OPC protocols will add Industrial PC

– Do not call it “CDWeb”. It is not.

• Keep existing power electronics in all cases.

– ThermaTrol I or II

– CalTrol I or II

– Calcoil 4000 (A or D)

• Note: new interface is NOT offered for Calcoil 2000, Impact

ThermaJet, or ABB ThermoProfiler, etc. These are all obsolete,

unsupported, and difficult to repair. Better to replace.

Page 16: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

Honeywell Proprietary

Honeywell.com

16

POV-221-110.01 MPU Replacement Chassis – October 2011

Process Solutions

New Profile Manager - Parallel I/O

• New AquaTrol systems use HC900 in Profile Manager type

enclosure.

– 4 contact outputs per zone to drive solenoid valves

– Modbus TCP protocol for direct connection to Experion MX, Da Vinci.

– ODX and OPC protocols will add Industrial PC

– Do not call it “CDWeb”. It is not.

• For legacy AquaTrols, same HC900 is available. Please confirm

solenoid voltage on inquiries

– 24 VDC solenoids [same as current systems]

– 24 VAC solenoids [legacy Measurex systems]

– 48 VDC solenoids [legacy Devron systems]

• For legacy AquaTrols, please ensure all tech bulletins have been

applied

Page 17: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

Honeywell Proprietary

Honeywell.com

17

POV-221-110.01 MPU Replacement Chassis – October 2011

Process Solutions

QCS to Actuator Links, FYI

• Experion MX and Da Vinci support:

– OPC, ODX, LON, Modbus TCP (to current actuators & interface)

– 200-100, SCL, Modbus RTU, ABB Microset (to legacy actuators &

interface)

• New Honeywell actuators support links to foreign / legacy QCS

using:

– OPC, ODX, Modbus TCP

– Modbus RTU

• New Honeywell actuators do NOT support these old serial

protocols:

– SCL

– 200-100

– ABB Microset

Page 18: MPU Replacement Chassis - Honeywell · Honeywell Proprietary Honeywell.com 3 POV-221-110.01 MPU Replacement Chassis – October 2011 Process Solutions NEW MPU Replacement Chassis

Honeywell Proprietary

Honeywell.com

18

POV-221-110.01 MPU Replacement Chassis – October 2011

Process Solutions

Questions?

• Contact Mark Bonner / Michelle Wardas / Jan McDonald for

Pricing Inquiries

• Contact Arash Dowlati, Jonathan Crawford, or Tom Steele with

technical questions

• Contact Jack Rumel for CD sales and application support.