mpu replacement chassis - honeywell · honeywell proprietary honeywell.com 3 pov-221-110.01 mpu...
TRANSCRIPT
MPU Replacement Chassis
October 2011
Honeywell Proprietary
Honeywell.com
2
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Legacy Measurex MPU Interface
• Measurex MPU Chassis from the
early 1980’s reached end-of-life
long ago.
– MPU was Measurex interface for
CD actuators
• ThermaTrol, AquaTrol, CalTrol,
SteamTrol
– MPU withdrawn from sale in 1992
• Replaced by Profile Managers with
GE 90/70 PLC
• Whatever parts still available
today are offered only under the
'repair exchange' procedure or a
'level 1 down' with return
afterwards.
Honeywell Proprietary
Honeywell.com
3
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
NEW MPU Replacement Chassis
• Digital Outputs ONLY:
– Duty cycle (ThermaTrol, CalTrol, Calcoil) or 4-bit parallel (AquaTrol)
• Standard I/O PCB: switch selectable duty cycle or 4-bit parallel
• 200-100 serial links ONLY (RS232 or FSK)
• Status feedback inputs NOT supported
• ScaniValve NOT supported
• CWS double-precision protocols NOT supported
Honeywell Proprietary
Honeywell.com
4
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Scope - MPU Replacement Kit
• Drop-in replacement for the MPU Chassis assembly
– Ref: Models 2573 and 2575 interface sub-systems in Production
Release documents
– Used for ThermaTrol, CalTrol, and AquaTrol actuators.
• The kit replaces the complete MPU chassis and all PCBs
– Ribbon-cable connections and functions all compatible with the
original chassis.
– All existing power-switching electronics and terminations to the
actuators are to be retained and remain unchanged.
– Replaced components include
• MPU Chassis / Power Supply (08343800),
• MPU Processor (05365800)
• PAV interface boards (05287000).
Honeywell Proprietary
Honeywell.com
5
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Success Story – Augusta Newsprint
From John Anderson (Field Service Specialist) 10/10/2011:
• The new and improved MPU upgrade kits dropped right
in. There is one card (processor) that requires some simple
configuration (a jumper and a switch). On the old MPU’s, the
Aquatrol, Thermatrol, and Caliper controls have unique processor
cards/proms. The MPU upgrade kits have cards are
interchangeable between other MPU upgrade kits, reducing the
amount of spares required.
• ….Things went great. We haven’t had any issues with them so
far – over a year.
Honeywell Proprietary
Honeywell.com
6
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Scope - continued
Old MPU chassis (left) is replaced by the drop-in
replacement kit (right)
Honeywell Proprietary
Honeywell.com
7
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Models 8891 & 8892
Items to order: Configuration & Quantities:
MPU Replacement Kit Chassis with Power
Supply & Processor, #09889100
Customer Sell Price: US$ $13,879.00 per set
Delivery: unforecasted lead time 22 weeks
Notes: (a) order from Vancouver ONLY. Limited
quantities on hand for prompt shipment.
Check before committing. (b) K&E Pricing
requires return of the old equipment to
Honeywell
Order qty 1 per actuator “beam” (ThermaTrol,
CalTrol, or AquaTrol)
Input voltage: 115 VAC, 50 / 60 Hz
Serial Link: RS232 or FSK
Protocol: 200-100 with 6-bit setpoints
MPU Replacement Kit Output PCB,
#09889200
Customer Sell Price: US$ $2891.00 each
Delivery: unforecasted lead time 22 weeks
* Notes: same as above
For Duty Cycle outputs to ThermaTrol, CalTrol,
Calcoil, order 1 per 32 zones (max 4 PCB)
Max number of zones per chassis: 128
Duty Cycle: 8-second time base with 125-
millisecond resolution (6-bit setpoint)
For 4-Bit Parallel outputs to AquaTrol;
order 1 per 8 zones (max 9 PCB)
Max number of zones per chassis:72
Honeywell Proprietary
Honeywell.com
8
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
BOM Breakdown
• Model 8891: MPU Replacement Kit Chassis with Power Supply &
Processor – List Price $13,879.00 (2011 SPM)
– Transfer Price $6999.00 (2011 SPM) – order as 09889100 includes
• Processor Card – Qty 1 Part No. : 6542800045
• Power supply module – Qty 1 Part No. : 6543140089
• Rack complete with back-plane – Qty 1 Part No. : 6543060055
• Installation Guide – Qty 1 Part No.: 6510020266
• Model 8892: MPU Replacement Kit Output PCB – List Price List $2891.00 USD (2011 SPM)
– Transfer Price: $1467.00 (2011 SPM)
– order as 09889200 includes • Digital output Card – Qty 1 Part No. : 6543140090
Honeywell Proprietary
Honeywell.com
9
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
MPU Replacement Chassis w/ 4 I/O PCB
• 1 x 8891 with 4 x 8892 I/O PCB’s, suitable for…
– 128-Zone ThermaTrol or CalTrol (duty cycle) OR
– 32-Zone AquaTrol (4-bit parallel)
Honeywell Proprietary
Honeywell.com
10
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
MPU Replacement Chassis w/ 9 I/O PCB
• 1 x 8891 with 9 x 8892 I/O PCB’s suitable for…
– 72-Zone AquaTrol (4-bit parallel)
Honeywell Proprietary
Honeywell.com
11
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Product Positioning
• Intended as a service K&E
• Low-cost way to avoid downtime & frustration due to lack of
replacement parts for the MPU chassis
– Literally minutes to install; ribbon cable compatible with MPU
– No software changes; same 200-100 link
• Preserves customer investment in legacy CD actuators without
demanding a technology upgrade
– 200-100 serial link only; LAN communication not supported
– A safe investment regardless of subsequent QCS upgrades
• Experion MX and Da Vinci speak 200-100 protocol
• Technology upgrades should consider actuator replacement, or
at least a new Profile Manager for LAN connectivity
Honeywell Proprietary
Honeywell.com
12
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Product Positioning
• Field proven: Trial units have been in field operation since
November 2010 without problem.
• MPU Replacement Kit must be ordered from Vancouver Service
Center.
• Limited number of kits on the shelf as of June 2011, and
available for prompt shipment. Check before making any
commitments
• Unforecasted lead time is 22 weeks
• Forecasted demand not yet established, so your inputs &
forecasts are needed to plan future inventory for fast deliveries.
• K&E Pricing requires return of the old equipment to Honeywell
Honeywell Proprietary
Honeywell.com
13
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Legacy Measurex Actuators & Interfaces
• ThermaTrol I or II – End of Life
– Recommend replacing the actuator with AutoSlice CDW, otherwise:
– If UNITEC interface, replace with HC900 based Profile Manager.
– If MPU, order MPU Replacement Chassis OR new Profile Manager
with duty-cycle interface
• AquaTrol – Still current
– Current product employs similar technology (different solenoids)
– If UNITEC interface, replace with HC900 based Profile Manager.
– If MPU, order MPU Replacement Chassis OR new Profile Manager
with 4-bit parallel outputs to solenoids.
• CalTrol I or II – End of Life
– Recommend replacing with Calcoil, otherwise:
– If UNITEC interface, replace with HC900 based Profile Manager.
– If MPU, order MPU Replacement Chassis OR new Profile Manager
with duty-cycle interface
Honeywell Proprietary
Honeywell.com
14
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Legacy Measurex Steambox & Interface
• SteamTrol – End of Life
– Very limited parts support; recommend replacement with Devronizer
– Note: XP10 steam actuator upgrade NOT available for SteamTrol
• ScaniValve interface - End of Life
– Unsupported
– Replace ScaniValve interface with IDP II (CDWeb)
– IDP for SteamTrol must be set up for 3-15 psi (not 6-30 psi)
• ODX, RTU Modbus, Modbus TCP, and OPC are currently supported
protocols.
• 200-100, SCL, or ABB Microset serial protocols are not supported by
CDWeb systems.
• Beware: HP or ET systems with only 200-100 links cannot use
IDP. Yet another reason to upgrade now.
Honeywell Proprietary
Honeywell.com
15
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
New Profile Manager - Duty Cycle I/O
• New Duty Cycle I/O systems use HC900 in Profile Manager type
enclosure.
– Used only for legacy actuators (no new actuators use duty cycle)
– Modbus TCP protocol for direct connection to Experion MX, Da Vinci.
– ODX and OPC protocols will add Industrial PC
– Do not call it “CDWeb”. It is not.
• Keep existing power electronics in all cases.
– ThermaTrol I or II
– CalTrol I or II
– Calcoil 4000 (A or D)
• Note: new interface is NOT offered for Calcoil 2000, Impact
ThermaJet, or ABB ThermoProfiler, etc. These are all obsolete,
unsupported, and difficult to repair. Better to replace.
Honeywell Proprietary
Honeywell.com
16
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
New Profile Manager - Parallel I/O
• New AquaTrol systems use HC900 in Profile Manager type
enclosure.
– 4 contact outputs per zone to drive solenoid valves
– Modbus TCP protocol for direct connection to Experion MX, Da Vinci.
– ODX and OPC protocols will add Industrial PC
– Do not call it “CDWeb”. It is not.
• For legacy AquaTrols, same HC900 is available. Please confirm
solenoid voltage on inquiries
– 24 VDC solenoids [same as current systems]
– 24 VAC solenoids [legacy Measurex systems]
– 48 VDC solenoids [legacy Devron systems]
• For legacy AquaTrols, please ensure all tech bulletins have been
applied
Honeywell Proprietary
Honeywell.com
17
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
QCS to Actuator Links, FYI
• Experion MX and Da Vinci support:
– OPC, ODX, LON, Modbus TCP (to current actuators & interface)
– 200-100, SCL, Modbus RTU, ABB Microset (to legacy actuators &
interface)
• New Honeywell actuators support links to foreign / legacy QCS
using:
– OPC, ODX, Modbus TCP
– Modbus RTU
• New Honeywell actuators do NOT support these old serial
protocols:
– SCL
– 200-100
– ABB Microset
Honeywell Proprietary
Honeywell.com
18
POV-221-110.01 MPU Replacement Chassis – October 2011
Process Solutions
Questions?
• Contact Mark Bonner / Michelle Wardas / Jan McDonald for
Pricing Inquiries
• Contact Arash Dowlati, Jonathan Crawford, or Tom Steele with
technical questions
• Contact Jack Rumel for CD sales and application support.