mro tek cd content

Upload: ivynash

Post on 01-Mar-2016

26 views

Category:

Documents


0 download

DESCRIPTION

Mro Tek CD Content Media Converter

TRANSCRIPT

  • FCAT1000-N

    Installation and User Guide

  • Copyrights

    This manual and the information contained herein is proprietary information and is intended for the exclusive use of MRO-TEK customers. The

    information in this manual should not be copied, distributed, shared or reproduced in any manner without the express written permission of

    MRO-TEK. Information contained in this document is subject to change. In the event of a change, this document will be revised.

    Restrictions

    The software described in this document is the property of MRO-TEK. It is furnished under a license agreement and may be used and/or disclosed

    only in accordance with the terms of the agreement. Software and documentation are copyright materials. Making unauthorized copies is prohibited by

    law. No part of the software or documentation may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language

    or computer language, in any form or by any means, without prior written permission of MRO-TEK.

    Accuracy

    While reasonable efforts have been made to assure the accuracy of this document, MRO-TEK assumes no liability resulting from any inaccuracies or

    omissions in this document, or from the use of the information obtained herein. MRO-TEK reserves the right to make changes to any products

    described herein to improve reliability, function, or design, and reserves the right to revise this document and to make changes from time to time in

    content hereof with no obligation to notify any person of revisions or changes. MRO-TEK does not assume any liability arising out of the application

    or use of any product or circuit described herein; neither does it convey license under its patent rights of others.

    Trademarks

    MRO-TEK and the MRO-TEK logo are registered trademarks of MRO-TEK Limited.

    All other brands and corporate names are trademarks of their respective owners.

    MRO-TEK LTD. Bellary Road, Hebbal, Bangalore - 560 024, INDIA Ph: +91 80 2333 2951 Fax: +91 80 2333 3415 Email: [email protected] Web: www.mro-tek.com

  • Version status of this manual

    The following shows the issue status of this manual since its release.

    Version information

    The following lists the versions of this manual in order of manual release:

    Table 1 Version information

    Manual version

    Date of release e Remarks

    1.0 July 2010 Original Issue 1.0

    1.1 December 2010 60Km Optics information update

    1.2 October 2012 MROTEK revised logo for 2012

    Text conventions

    In the manual, new and amended features are tagged to help users to assess the impact. The tags include index references which are listed in the manual Index.

    Table 2: Text convention

    ICON Notice Type Alerts

    NOTE

    Important feature or instruction.

    Caution

    Risk of personal injury, system damage, or loss of data

    Warning

    Risk of severe personal injury

    The tags are positioned in text as follows:

    Cross references

    Throughout this manual, references are made to external publications, chapter numbers and section names. The references to external publications are shown in italics, chapter and section name cross references are emphasized in bold.

    2010

    All Rights Reserved

  • Table

    of Contents

    Contents FCAT1000-N

    Chapter 1 Overview of FCAT1000-N ......................................................................................................... 1-1 Introduction................................................................................................................................................................. 1-2

    Specification ....................................................................................................................................................... 1-2 Fiber Optic Specifications ................................................................................................................................... 1-3 Features.............................................................................................................................................................. 1-3 Physical Description............................................................................................................................................ 1-4

    Chapter 2 Installation and Setup.................................................................................................................. 2-1 Installation .................................................................................................................................................................. 2-2

    Package Content ................................................................................................................................................ 2-2

    Installing FCAT1000-N ..................................................................................................................................... 2-2 Site Requirement and prerequisites.................................................................................................................... 2-2 Connecting the interfaces ................................................................................................................................... 2-3 Connecting to Power........................................................................................................................................... 2-3 Connecting the Ethernet Interface ...................................................................................................................... 2-3 Connecting the SC Interface............................................................................................................................... 2-4 Application .......................................................................................................................................................... 2-4

    Chapter 3 Operation ...................................................................................................................................... 3-1

    Operating FCAT1000-N........................................................................................................................................... 3-2

    Turning on FCAT1000-N .................................................................................................................................. 3-2 LED Indicators .................................................................................................................................................... 3-2 DIP Switch .......................................................................................................................................................... 3-3

    Installation .................................................................................................................................................................. 3-4

    Chapter 4 Appendix A ................................................................................................................................... 4-1 Safety Notices ............................................................................................................................................................ 4-2

    Safety Precautions.............................................................................................................................................. 4-2 Modifications to Equipment................................................................................................................................. 4-2 Placement of the unit .......................................................................................................................................... 4-2

    Chapter 5 Appendix B ................................................................................................................................... 5-1 F.A.Q.......................................................................................................................................................................... 5-2

    i

  • List of

    Figures

    List of Figures Figure 1: FCAT1000-N ...................................................................................................................................................1-4

    Figure 2: Front Panel of FCAT1000-N media converter .................................................................................................2-3 Figure 3: Application..........................................................................................................................................................2-4 Figure 4: Front Panel LED indicators ................................................................................................................................3-2

    ii

  • List of Tables Table 1 Version information ................................................................................................................................................. 1 Table 2: Text convention...................................................................................................................................................... 1

    1-1

  • Chapter 1 Overview of FCAT1000-N

    1-1

  • Introduction FCAT1000-N

    Introduction

    The FCAT1000-N is a single channel stand-alone Media converters provide media conversion from 1000Base-TX to 1000 Base-FX on multimode or single mode fiber up to 60kms. Available in Stand-alone, internal auto ranging AC/DC Power supplies and a versatile range of Fiber Optic interfaces, FCAT1000-N becomes a complete offering to suit Carriers, Service Providers and Enterprises for wide range of deployments.

    It is an Unmanaged Gigabit Ethernet Media converter, which supports a variety of advanced features and flexible interface options, giving service providers the power to quickly and profitably deploy Ethernet services. Enterprise customers can leverage existing Gigabit Ethernet infrastructure for long haul connects.

    FCAT1000-N is a rugged and reliable Gigabit Ethernet media converter providing seamless extension of Gigabit Ethernet on single mode/multi mode fiber up to 60 kms. It is very flexible and it adapts to different connectivity needs make this product an essential component of any network design.

    Specification

    Standards Compliance IEEE 802.3ab, IEEE 802.3z

    1000BASE-TX, 1000BASE-FX

    1000BASE-TX port: Shielded RJ-45

    Duplex support Half/Full

    Auto MDI-I / MDI-X

    1000Base-FX port SC connector

    LED Indicators

    PWR (green) Power status

    Link(LNK) Link Status for Ethernet ports

    Activity (ACT) Activity status for Ethernet ports

    LFP Link Fault Propagation Indication for Ethernet ports

    FEF Far End Fault Indication for Ethernet ports

    DIP Switch

    SW1 Link Fault Enable/Disable

    SW2-SW4 Not Connected

    Power

    Stand-alone

    AC 100 to 240 VAC, 1.85 W

    DC -36 to -72 VDC, 1.85 W

    1-2

  • FCAT1000-N Introduction

    ENVIRONMENTAL

    Operating temperature 0 to 50 C (32-122 F)

    Storage temperature -30 to 65 C (-22 to 149 F)

    Humidity 10 to 90% Non-condensing

    Fiber Optic Specifications

    Module Type

    Wavelength (nm)

    Fiber Type (m) Typical Tx Power (dBm)

    Typical Rx Sensitivity (dBm)

    Typical Range (Kms)

    MM 850 62.5/125 Multimode -6 -14 0.22

    MM 850 50/125 Multimode -6 -14 0.5

    SM10 1310 9/125 Single mode -6 -18 15

    SM40 1310 9/125 Single mode 1 -19 40

    SM60 1550 9/125 Single mode 0.5 -20 60

    SF15 1310/1550 9/125 Single mode SF -6 -18 15

    SF40 1310/1550 9/125 Single mode SF 0.5 -19 40

    Features

    Single channel standalone media converter Media Conversion from 1000BASE-TX to 1000BASE-FX Auto MDI-I/MDI-X copper Ethernet port RJ-45 connector for 1000BASE-TX port SC connector for 1000BASE-FX port Link and Activity, FEF, LFP LED indications FEF indication for both remote side fiber and copper LFP propagation of both from copper to fiber and fiber to copper Supports multi mode or single mode fiber Single mode option available up to 60 km Internal auto-ranging AC or DC power supply Configuration using DIP Switches

    1-3

  • Introduction FCAT1000-N

    Physical Description

    Figure 1 shows a 3D view of the FCAT1000-N unit in the enclosure.

    The front panel of a desktop unit includes SC connector, Copper Ethernet port and several LED indicators which display the status of power, link and activity indicators.

    Figure 1: FCAT1000-N

    1-4

  • Chapter 2 Installation and Setup

    2-1

  • Installation FCAT1000-N

    Installation

    This chapter describes installation and setup procedures for the standalone FCAT1000-N media converter.

    Internal settings, adjustment, maintenance and repairs may be performed only by a skilled technician who is aware of the hazards involved.

    Always observe standard safety precautions during installation, operation and maintenance of this product.

    The FCAT1000-N media converter is designed for standalone installation and is delivered as a fully assembled unit.

    Package Content

    The FCAT1000-N package includes the following items:

    One FCAT1000-N unit Technical documentation CD AC or DC power cords

    Installing FCAT1000-N

    The installation of the FCAT1000-N media converter includes the following steps,

    Connecting the unit to power mains Connecting the SC interface Connecting the Ethernet interface

    Site Requirement and prerequisites

    AC-powered FCAT1000-N units should be installed within 1.5m (5 ft) of an easily-accessible grounded AC outlet capable of furnishing the voltage in accordance with FCAT1000-N nominal supply voltage.

    DC-powered FCAT1000-N units require a -36 to -72 VDC power source, which must be adequately isolated from the main supply.

    The ambient operating temperature of FCAT1000-N should be 0 to 50C, at a relative humidity of up to 90%, non-condensing.

    2-2

  • FCAT1000-N Installation

    Connecting the interfaces

    Figure 2 shows a typical front panel of FCAT1000-N media converter with an Ethernet interface, SC interface and power LED.

    Figure 2: Front Panel of FCAT1000-N media converter

    Connecting to Power

    FCAT1000-N is equipped with either AC or DC power supply. AC or DC power is supplied to FCAT1000-N via a standard power input connector on the rear panel.

    Connecting to AC Power AC power should be supplied through the standard power cable terminated by a standard plug. The AC power chord is provided along with the unit.

    To connect AC power:

    1. Connect the power cable to the power connector on the FCAT1000-N rear panel.

    2. Connect the power cable to the mains outlet.

    The unit turns on automatically upon connection to the mains.

    Connecting to DC Power DC power is supplied to FCAT1000-N via a compatible DC cable for attaching -48V DC power supply lines. While connecting to the DC power mains, the polarity needs to be taken care as per the indications provided on the DC cable.

    The DC power cord is provided along with the unit.

    Connecting the Ethernet Interface

    Ethernet interface uses RJ45 connector

    To connect Ethernet interface

    Connect the line cable to the RJ-45 connector designated to Ethernet interface.

    2-3

  • Installation FCAT1000-N

    Connecting the SC Interface

    The FCAT1000-N has SC interface.

    To connect SC interface

    Connect the cable to the designated SC interface located on the front panel.

    Application

    The below figures illustrates FCAT1000-N applications, It is designed for demanding network

    environments to provide high speed and reliable connects. It can typically be used in a LAN,

    MAN or in a Campus Network.

    Figure 3: Application

    2-4

  • Chapter 3 Operation

    3-1

  • Operating FCAT1000-N FCAT1000-N

    Operating FCAT1000-N

    This chapter provides the following information for FCAT1000-N Media converter

    Operating procedures (Power-ON, Performance Monitoring and Power-OFF) FCAT1000-N LED indicators

    Turning on FCAT1000-N

    To turn on FCAT1000-N:

    Connect the power cord to the AC/DC power mains. The PWR indicator lights up and remains lit as long as FCAT1000-N is receiving power.

    FCAT1000-N requires no operator attention once installed, with the exception of occasional monitoring of front panel indicators. Intervention is only required when FCAT1000-N needs to be configured to its operational requirements or diagnostic tests to be performed.

    LED Indicators

    The front panel of FCAT1000-N includes a series of LED indicators that shows the current operating status of the unit.

    LED Indicator description Figure 5 shows the front panel of FCAT1000-N unit.

    Figure 4: Front Panel LED indicators

    3-2

  • FCAT1000-N Operating FCAT1000-N

    Interface Type

    Color Indicat

    or Name

    Indicator Meaning

    Function

    Power Supply

    Green PWR Power Indicator ON: Unit is powered ON

    OFF: Unit is not receiving Power

    Activity Green ACT Activity status Flashing: Activity status for Ethernet port

    TX-LNK

    Copper Link ON: Copper Link is active

    Link Green FX-LNK

    Fiber Link ON: Fiber Link is active

    TX-LFP Link Fault

    Propagation in Copper

    ON: LFP in Copper

    LFP Green

    FX-LFP Link Fault

    Propagation in Fiber

    ON: LFP in Fiber

    TX-FEF Far End Faul

    Copper t ON: FEF in Copper

    FEF Yellow

    FX-FEF Far End Fault

    Fiber ON: FEF in Fiber

    DIP Switch

    SW1: Link Fault Enable/Disable

    SW2-SW4: Not Connected

    3-3

  • Installation FCAT1000-N

    Installation

    Following are the installation procedure to install FCAT1000-N

    1 Connect a fiber patch chord Type (single/multi mode) and SC interface on FCAT1000-N to the FX port.

    2 Connect a CAT 5 UTP cable to the corresponding TX port and terminate it on the Ethernet port of the terminal equipment (Typically a switch/PC/server)

    3 Repeat step two at the remote side of the fiber.

    4 After switching on, check if the FX link is up, or else swap TX and RX patch chord of the corresponding FX port.

    5 Once FX link is up, check the TX link status and ensure it is up.

    3-4

  • Chapter 4 Appendix A

    4-1

  • Safety Notices FCAT1000-N

    Safety Notices

    For your protection, observe the following safety precautions when setting up your equipment:

    Safety Precautions

    Read the following safety information thoroughly before installing the FCAT1000-N.

    Always observe standard safety precautions during installation, operation and maintenance of this product. Only qualified and authorized service personnel should carry out adjustment, maintenance or repairs to this product.

    No User-serviceable parts in the equipment. Installation and removal of module should be done by qualified personnel only. Follow all cautions and instructions if marked on the equipment supplied. Do not make mechanical or electrical modifications to the equipment. MRO-TEK Limited is

    not responsible for regulatory compliance of a modified MRO-TEK Limited product.

    Never place an MRO-TEK Limited product near a radiator or heat register. Failure to follow these guidelines can cause overheating and affect the reliability of the device.

    Modifications to Equipment

    Do not make mechanical or electrical modifications to the equipment. MRO-TEK Limited is not responsible for regulatory compliance of a modified MRO-TEK Limited product.

    Placement of the unit

    Do not block or cover the opening vents of your purchased product. Never place the unit near a radiator or heat register. Failure to follow these guidelines can cause overheating and affect the reliability of the device.

    4-2

  • Chapter 5 Appendix B

    5-1

  • FCAT1000-N

    F.A.Q

    Problem Indication Corrective Action

    Check if the power supply cable is firmly connected to the main power supply

    Check if the AC input power source is between 100 and 240VAC. (Check if the source voltage is between 36VDC to 72VDC for a DC Box)

    No Power Main power

    LED is not glowing

    Check the fuse on AC mains supply

    Check whether the connected devices port is active.

    Check if the cable is faulty.

    Copper link not active

    TX Link LED is not glowing

    (TX LINK) Reset the device and try again

    Check if the receive fiber of the local device is properly connected to the transmit port of the remote fiber device and the transmit port to the receive port of the remote device

    Ensure that the cables are inserted properly.

    Check whether the connected remote device is active.

    If the problem persists, then repeat the above-mentioned steps at the remote device.

    If the link still does not come up, ensure that the fiber link is functional, using an OTDR equipment measure the fiber loss and ensure that the loss is less than the product power budget.

    Fiber link not active

    FX Link LED (1000Base-FX is not glowing)

    Reset the device and try again

    Improper network traffic / slowed down traffic

    Excess collisions Verify that all devices (both FCAT and the devices interconnected by them) are set to the same Duplex mode, 1000 Mbps data rate, and set to Auto negotiation enable.

    5-2

    CopyrightsVersion status of this manualVersion informationText conventionsCross referencesContentsList of FiguresList of Tables

    Chapter 1 Overview of FCAT1000-NIntroductionSpecification Fiber Optic SpecificationsFeatures Physical Description

    Chapter 2 Installation and SetupInstallationPackage ContentInstalling FCAT1000-NSite Requirement and prerequisites Connecting the interfacesConnecting to PowerConnecting the Ethernet InterfaceConnecting the SC InterfaceApplication

    Chapter 3 OperationOperating FCAT1000-NTurning on FCAT1000-N LED IndicatorsDIP Switch

    Installation

    Chapter 4 Appendix ASafety NoticesSafety PrecautionsModifications to EquipmentPlacement of the unit

    Chapter 5 Appendix BF.A.Q