88 SELECTION Choose from seven types of indoor units and twelve outdoor units that can run up to six indoor units each. Create the system that best matches room shapes and number of rooms. SELECT INDOOR UNITS Select the indoor unit to be installed in each room. Wall-mounted Floor-standing Cassette Ceiling-suspended Ceiling-concealed SELECT OUTDOOR UNITS Select the best outdoor unit based on the number of indoor units and overall system capacity required. 2-port Connect up to 2 indoor units 3-port Connect up to 3 indoor units 4-port Connect up to 4 indoor units 5-port Connect up to 5 indoor units 6-port Connect up to 6 indoor units 4-port Connect up to 4 indoor units CHECK SYSTEM COMPATIBILITY Possible combinations depends on the outdoor unit chosen. Please check the following points. Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with the outdoor unit selected. (Indoor units not listed in the table cannot be used.) Refer to the “Combination Table” to check if the capacity combination of the indoor unit selected is connectable. (Combinations not listed cannot be connected.) Check Indoor Unit Capacity Combination If the desired combination cannot be found, please change either the indoor or outdoor unit to match one of the combinations shown in the tables. Check Indoor Units MXZ-5E102VA MXZ-6D122VA MXZ-4E72VA MXZ-4E83VA STEP 1 STEP 2 STEP 3 MXZ-4E83VAHZ 2-port Connect up to 2 indoor units MXZ-2E53VAHZ MSZ-FH MSZ-EF MSZ-SF (15 20) MSZ-GF MSZ-SF (25-50) MFZ-KJ SLZ-KF PLA MLZ-KA PCA SEZ-KD PEAD HYPER HEATING* *Refer to page101 and page 109 for detailed information. MXZ-2D33VA(2) MXZ-2D42VA(2) MXZ-2D53VA(H) MXZ-3E54VA MXZ-3E68VA

Upload: others

Post on 26-Mar-2020

16 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MULTI - Narkissos Aircon Limassol Cyprus · MXZ-5E102VA M SZ-EF18VE2 + MSZ-EF18VE2 + MSZ-EF22VE2 + MSZ-EF22VE2 + MSZ-EF22VE2 *5 Power input and operating current (max) ƒgures are

88

SERIES

SELECTIONChoose from seven types of indoor units and twelve outdoor units that can run up to six indoor units each. Create the system that best matches room shapes and number of rooms.

MULTISPLIT

SELECT INDOOR UNITSSelect the indoor unit to be installed in each room.

Wall-mounted Floor-standing Cassette Ceiling-suspended

Ceiling-concealed

SELECT OUTDOOR UNITSSelect the best outdoor unit based on the number of indoor units and overall system capacity required.

2-port Connect up to 2 indoor units 3-port Connect up to 3 indoor units 4-port Connect up to 4 indoor units

5-port Connect up to 5 indoor units 6-port Connect up to 6 indoor units 4-port Connect up to 4 indoor units

CHECK SYSTEM COMPATIBILITYPossible combinations depends on the outdoor unit chosen. Please check the following points.

Refer to the “Indoor Unit Compatibility Table” to check if the indoor units selected can be used with the outdoor unit selected. (Indoor units not listed in the table cannot be used.)

Refer to the “Combination Table” to check if the capacity combination of the indoor unit selected is connectable. (Combinations not listed cannot be connected.)

Check Indoor Unit CapacityCombination

If the desired combination cannot be found, please change either the indoor or outdoor unit to match one of the combinations shown in the tables.

Check Indoor Units

MXZ-5E102VA MXZ-6D122VA

MXZ-4E72VA MXZ-4E83VA

STEP 1

STEP 2

STEP 3

MXZ-4E83VAHZ

2-port Connect up to 2 indoor units

MXZ-2E53VAHZ

MSZ-FH

MSZ-EF

MSZ-SF (15 •20)

MSZ-GF

MSZ-SF (25-50)

MFZ-KJ

SLZ-KF

PLA

MLZ-KA

PCA

SEZ-KD

PEAD

HYPER HEATING*

*Refer to page101 and page 109 for detailed information.

MXZ-2D33VA(2)MXZ-2D42VA(2)MXZ-2D53VA(H)

MXZ-3E54VAMXZ-3E68VA

Page 2: MULTI - Narkissos Aircon Limassol Cyprus · MXZ-5E102VA M SZ-EF18VE2 + MSZ-EF18VE2 + MSZ-EF22VE2 + MSZ-EF22VE2 + MSZ-EF22VE2 *5 Power input and operating current (max) ƒgures are

89

MXZ SERIESAdvancements in the MXZ Series include e�ciency and exibility in system expansion capabilities. The best solution when requiring multi-system air conditioning needs.

OutdoorUnit

EXAMPLE SYSTEM

Handle Up to 6 Rooms with a Single Outdoor Unit

Wiring/Piping Correction Function* (3D54/3D68/4D72/4E83/5E102/6D122)

Support Functions

The MXZ Series o�ers a ten-system line-up to choose from, ranging between 3.3 and 12.2kW. All of them are compatible with speci�c M, S and P series indoor units. A single outdoor unit can handle a wide range of building layouts.

2-port 3-port 4-port 4-port 5-port 6-port

MXZ-2D33VA(2)MXZ-2D42VA(2)MXZ-2D53VA (H)

MXZ-4E83VAMXZ-5E102VA

MXZ-3E54VAMXZ-3E68VAMXZ-4E72VA

MXZ-6D122VA

MXZ-6D122VA system

Simply press a single button to con�rm if wiring and piping are properly connected. Wiring errors are corrected automatically when discovered. This eliminates the need to con�rm complicated wiring connections when expanding the system. (For details, refer to the outdoor unit instal-lation manual.)* Function cannot be used when the outdoor temperature is below 0°C.

The correction process requires 10–20 minutes to complete and must be conducted with the unit set to the “Cooling” mode.

Ampere Limit Adjustment*(4E83/5E102/6D122)

Dipswitch settings can be used to adjust the maximum electrical current for operation. This function is highly recommended for managing energy costs. (For details, refer to the outdoor unit installation manual.)* Maximum capacity is lowered with the use of this function.

Operation Lock

To accommodate speci�c use applications, cooling or heating operation can be speci�ed when setting the control board of the outdoor unit. A convenient option when a system needs to be con�gured for exclusive cooling or heating service. (For details, refer to the outdoor unit installa-tion manual.)

Wiringconfirmation

is timeconsuming.

The outdoor unit matches

pipes and wiring.

MXZ-6D122VA

2D-4E83

Up to 2 Indoor Units

Cooling

Heating(Average Season)

Max. Operating Current (Indoor+Outdoor)

Outdoor Unit

Ext. Piping

Guaranteed Operating Range [Outdoor]

SourceOutdoor (V/Phase/Hz)Capacity

Input (Indoor+Outdoor)Design LoadAnnual Electricity Consumption*2

SEER*4

Capacity

Input (Indoor+Outdoor)Design LoadDeclaredCapacity

Back Up Heating CapacityAnnual Electricity Consumption*2

SCOP*4

DimensionsWeightAir Volume

Sound Level (SPL)

Sound Level (PWL)Breaker SizeDiameter

Total Piping Length (max)Each Indoor Unit Piping Length (max)

RatedMin - MaxRated

Energy E�ciency Class*4

RatedMin - MaxRated

at reference design temperatureat bivalent temperatureat operation limit temperature

Energy E�ciency Class*4

H × W × D 550 - 800 (+69) - 285 (+59.5) 710 - 840 (+30) - 330 (+66) 796 - 950 - 330

CoolingHeatingCooling

CoolingHeating

Liquid

CoolingHeating

kWkWkWkW

kWh/a

kWkWkWkWkWkWkWkW

kWh/a

Ammkg

m3/minm3/mindB(A)dB(A)dB(A)

Amm

Gas mmmm

Max. Height mChargeless Length m

oCoC

R410A*1

Outdoor power supply230 / Single / 50

Please refer to (*4)N: MXZ-2D33VA(2) N: MXZ-2D42VA(2) N: MXZ-2D53VA N: MXZ-2D53VAH N: MXZ-3E54VA2 N: MXZ-3E68VA N: MXZ-4E72VA MXZ-4E83VA MXZ-5E102VA

Type (Inverter Multi - Split Heat Pump)Indoor UnitOutdoor UnitRefrigerant

Power Supply

3.31.1 - 3.8

0.903.32115.5A

4.01.0 - 4.1

0.962.72.12.41.70.69264.1A+

10.0

3232.933.749506310

6.35 × 29.52 × 2

201510 20

–10 ~ +46–15 ~ +24

4.21.1 - 4.4

1.00

4.22196.7

A++

4.51.0 - 4.8

0.933.22.73.02.30.5

10654.2

A+

12.2

3727.733.3465160

15 6.35 × 2 9.52 × 2

3020

15 (10)*3

20 –10 ~ +46–15 ~ +24

5.31.1 - 5.6

1.545.32627.1

A++

6.41.0 - 7.0

1.704.53.74.03.30.8

15074.2A+

12.2

3732.933.350536415

6.35 × 29.52 × 2

3020

15 (10)*3

20–10 ~ +46–15 ~ +24

5.31.1 - 5.6

1.545.32627.1

A++

6.41.0 - 7.0

1.704.53.64.03.00.9

15464.1A+

12.2

3832.933.350536415

6.35 × 29.52 × 2

3020

15 (10)*3

20–10 ~ +46–20 ~ +24

5.42.9 - 6.8

1.35

5.42956.4

A++

7.02.6 - 9.0

1.595.0

4.004.493.171.0017514.0

A+

18.0

5842.143.0505364

256.35 × 39.52 × 3

5025

15 (10)*3

40–10 ~ +46–15 ~ +24

6.82.9 - 8.4

2.196.84255.6A+

8.62.6 - 10.6

2.386.85.46.04.41.4

24663.9A

18.0

5842.143.050536425

6.35 × 39.52 × 3

6025

15 (10)*3

40–10 ~ +46–15 ~ +24

7.23.7 - 8.8

2.257.24435.7A+

8.63.4 - 10.7

2.287.05.66.24.71.4

25163.9A

18.0

5942.143.050536425

6.35 × 412.7×1+9.52×3

6025

15 (10)*3

40–10 ~ +46–15 ~ +24

8.33.7 - 9.2

2.448.34606.3

A++

9.33.4 - 11.6

2.008.77.17.86.01.6

28844.2A+

21.4

6255.655.649516125

6.35 × 412.7×1+9.52×3

7025

15 (10)*3

25–10 ~ +46–15 ~ +24

10.23.9 - 11.0

3.1510.25376.6

A++

10.54.1 - 14.0

2.348.97.37.96.31.6

29584.2A+

21.4

6365.168.052566525

6.35 × 512.7×1+9.52×4

8025

15 (10)*3

0–10 ~ +46–15 ~ +24

Up to 3 Indoor Units Up to 4 Indoor Units Up to 5 Indoor Units

Up to 6 Indoor Units

Cooling

Heating

Operating Current (max)*5

Outdoor Unit

Ext. Piping

Guaranteed Operating Range [Outdoor]

SourceOutdoor (V/Phase/Hz)Capacity

Input*5

EER*6

Capacity

Input*5

COP*6

DimensionsWeightAir Volume

Sound Level (SPL)

Sound Level (PWL)Breaker SizeDiameter

Total Piping Length (max)Each Indoor Unit Piping Length (max)

Rated

Rated

EEL RankRated

Rated

EEL Rank

H × W × D

CoolingHeatingCooling

CoolingHeating

Liquid

CoolingHeating

kW

kW

Min - Max kW

kWMin - Max kW

kW

A

mmkg

m3/minm3/mindB(A)dB(A)dB(A)

Amm

Gas mmmm

Max. Height mChargeless Length m

oCoC

R410A*1

Outdoor power supply230 / Single / 50

Please refer to (*5)

MXZ-6D122VA

Type (Inverter Multi - Split Heat Pump)Indoor UnitOutdoor UnitRefrigerant

Power Supply

12.23.5 - 13.5

3.663.33

A14.0

3.5 - 16.53.314.23

A26.8

1048 - 950 - 33088

63.077.055576932

6.35 × 612.7×1+9.52×5

8025

15 (10)*3

30–10 ~ +46–15 ~ +24

*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant �uid with a GWP equal to 1975. This means that if 1kg of this refrigerant �uid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.

*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.*3 If the outdoor unit is installed higher than the indoor unit, max. height is reduced to 10m.*4 EER/COP, EEL rank, SEER/SCOP values and energy e�ciency class are measured

when connected to the indoor units listed below.MXZ-2D33VA MSZ-SF15VA + MSZ-EF18VEMXZ-2D42VA MSZ-EF18VE2 + MSZ-EF25VE2MXZ-2D53VA(H) MSZ-EF18VE2 + MSZ-EF35VE2MXZ-3D54VA2 MSZ-EF18VE2 + MSZ-EF18VE2 + MSZ-EF18VE2MXZ-3D68VA MSZ-EF18VE2 + MSZ-EF25VE2 + MSZ-EF25VE2MXZ-4D72VA MSZ-EF18VE2 + MSZ-EF18VE2 + MSZ-EF18VE2 + MSZ-EF18VE2MXZ-4E83VA MSZ-EF18VE2 + MSZ-EF18VE2 + MSZ-EF22VE2 + MSZ-EF25VE2MXZ-5E102VA MSZ-EF18VE2 + MSZ-EF18VE2 + MSZ-EF22VE2 + MSZ-EF22VE2 + MSZ-EF22VE2

*5 Power input and operating current (max) �gures are for outdoor unit only*6 EER/COP, EEL rank, values and energy e�ciency class are measured

when connected to the indoor units listed below.MXZ-6D122VA MSZ-EF22VE × 6

N: Please refer to the NOTE below.

INVERTER MULTIMXZ SERIES

Please fill out the requested informationPlease fill out the requested information

NOTEWhen connecting the MFZ-KJ series indoor unit(s) to this outdoor unit, charge additional refrigerant according to the instructions in the diagram below.

MXZ-2D33VA

No. ofMFZ-KJ indoor units

Maximum amountof refrigerant

Pipe length (L)~20m

100g additional (Total 1250g)1 unit2 units

1250g

MXZ-2D42VA MXZ-2D53VA MXZ-2D53VAH

No. ofMFZ-KJ indoor units

Maximum amountof refrigerant

Pipe length (L)~20m

100g additional (Total 1400g)200g additional (Total 1500g)

~30m100g+{(L-20)m×20g/m)}200g+{(L-20)m×20g/m)}

1 unit2 units

1600g1700g

MXZ-3D54VA2

No. ofMFZ-KJ indoor units

Maximum amountof refrigerant

Pipe length (L)~40m

100g additional (Total 2800g)200g additional (Total 2900g)300g additional (Total 3000g)

~50m100g+{(L-40)m×20g/m)}200g+{(L-40)m×20g/m)}300g+{(L-40)m×20g/m)}

1 unit2 units3 units

3000g3100g3200g

MXZ-3D68VA MXZ-4D72VA

No. ofMFZ-KJ indoor units

Maximum amountof refrigerant

Pipe length (L)~40m

100g additional (Total 2800g)200g additional (Total 2900g)300g additional (Total 3000g)

~60m100g+{(L-40)m×20g/m)}200g+{(L-40)m×20g/m)}300g+{(L-40)m×20g/m)}

1 unit2 units3 units

3200g3300g3400g

Not available (Only one MFZ-KJ series indoor unit can be connected.)

MSZ-FH

MLZ-KA

MSZ-SF

MSZ-EF

SLZ-KF

MFZ-KJ

4E83-6D 3D-4D72

Number of MFZ-KJ should be one or two when connected to MXZ-4D72VA. If three and more MFZ-KJ are connected, use other outdoor units, such as MXZ-3D68VA and MXZ-4E83VA.

Page 3: MULTI - Narkissos Aircon Limassol Cyprus · MXZ-5E102VA M SZ-EF18VE2 + MSZ-EF18VE2 + MSZ-EF22VE2 + MSZ-EF22VE2 + MSZ-EF22VE2 *5 Power input and operating current (max) ƒgures are

90

MXZ SERIESAdvancements in the MXZ Series include e�ciency and exibility in system expansion capabilities. The best solution when requiring multi-system air conditioning needs.

OutdoorUnit

EXAMPLE SYSTEM

Handle Up to 6 Rooms with a Single Outdoor Unit

Wiring/Piping Correction Function* (3D54/3D68/4D72/4E83/5E102/6D122)

Support Functions

The MXZ Series o�ers a ten-system line-up to choose from, ranging between 3.3 and 12.2kW. All of them are compatible with speci�c M, S and P series indoor units. A single outdoor unit can handle a wide range of building layouts.

2-port 3-port 4-port 4-port 5-port 6-port

MXZ-2D33VA(2)MXZ-2D42VA(2)MXZ-2D53VA (H)

MXZ-4E83VAMXZ-5E102VA

MXZ-3E54VAMXZ-3E68VAMXZ-4E72VA

MXZ-6D122VA

MXZ-6D122VA system

Simply press a single button to con�rm if wiring and piping are properly connected. Wiring errors are corrected automatically when discovered. This eliminates the need to con�rm complicated wiring connections when expanding the system. (For details, refer to the outdoor unit instal-lation manual.)* Function cannot be used when the outdoor temperature is below 0°C.

The correction process requires 10–20 minutes to complete and must be conducted with the unit set to the “Cooling” mode.

Ampere Limit Adjustment*(4E83/5E102/6D122)

Dipswitch settings can be used to adjust the maximum electrical current for operation. This function is highly recommended for managing energy costs. (For details, refer to the outdoor unit installation manual.)* Maximum capacity is lowered with the use of this function.

Operation Lock

To accommodate speci�c use applications, cooling or heating operation can be speci�ed when setting the control board of the outdoor unit. A convenient option when a system needs to be con�gured for exclusive cooling or heating service. (For details, refer to the outdoor unit installa-tion manual.)

Wiringconfirmation

is timeconsuming.

The outdoor unit matches

pipes and wiring.

MXZ-6D122VA

2D-4E83

Up to 2 Indoor Units

Cooling

Heating(Average Season)

Max. Operating Current (Indoor+Outdoor)

Outdoor Unit

Ext. Piping

Guaranteed Operating Range [Outdoor]

SourceOutdoor (V/Phase/Hz)Capacity

Input (Indoor+Outdoor)Design LoadAnnual Electricity Consumption*2

SEER*4

Capacity

Input (Indoor+Outdoor)Design LoadDeclaredCapacity

Back Up Heating CapacityAnnual Electricity Consumption*2

SCOP*4

DimensionsWeightAir Volume

Sound Level (SPL)

Sound Level (PWL)Breaker SizeDiameter

Total Piping Length (max)Each Indoor Unit Piping Length (max)

RatedMin - MaxRated

Energy E�ciency Class*4

RatedMin - MaxRated

at reference design temperatureat bivalent temperatureat operation limit temperature

Energy E�ciency Class*4

H × W × D 550 - 800 (+69) - 285 (+59.5) 710 - 840 (+30) - 330 (+66) 796 - 950 - 330

CoolingHeatingCooling

CoolingHeating

Liquid

CoolingHeating

kWkWkWkW

kWh/a

kWkWkWkWkWkWkWkW

kWh/a

Ammkg

m3/minm3/mindB(A)dB(A)dB(A)

Amm

Gas mmmm

Max. Height mChargeless Length m

oCoC

R410A*1

Outdoor power supply230 / Single / 50

Please refer to (*4)N: MXZ-2D33VA(2) N: MXZ-2D42VA(2) N: MXZ-2D53VA N: MXZ-2D53VAH N: MXZ-3E54VA2 N: MXZ-3E68VA N: MXZ-4E72VA MXZ-4E83VA MXZ-5E102VA

Type (Inverter Multi - Split Heat Pump)Indoor UnitOutdoor UnitRefrigerant

Power Supply

3.31.1 - 3.8

0.903.32115.5A

4.01.0 - 4.1

0.962.72.12.41.70.69264.1A+

10.0

3232.933.749506310

6.35 × 29.52 × 2

201510 20

–10 ~ +46–15 ~ +24

4.21.1 - 4.4

1.00

4.22196.7

A++

4.51.0 - 4.8

0.933.22.73.02.30.5

10654.2

A+

12.2

3727.733.3465160

15 6.35 × 2 9.52 × 2

3020

15 (10)*3

20 –10 ~ +46–15 ~ +24

5.31.1 - 5.6

1.545.32627.1

A++

6.41.0 - 7.0

1.704.53.74.03.30.8

15074.2A+

12.2

3732.933.350536415

6.35 × 29.52 × 2

3020

15 (10)*3

20–10 ~ +46–15 ~ +24

5.31.1 - 5.6

1.545.32627.1

A++

6.41.0 - 7.0

1.704.53.64.03.00.9

15464.1A+

12.2

3832.933.350536415

6.35 × 29.52 × 2

3020

15 (10)*3

20–10 ~ +46–20 ~ +24

5.42.9 - 6.8

1.35

5.42956.4

A++

7.02.6 - 9.0

1.595.0

4.004.493.171.0017514.0

A+

18.0

5842.143.0505364

256.35 × 39.52 × 3

5025

15 (10)*3

40–10 ~ +46–15 ~ +24

6.82.9 - 8.4

2.196.84255.6A+

8.62.6 - 10.6

2.386.85.46.04.41.4

24663.9A

18.0

5842.143.050536425

6.35 × 39.52 × 3

6025

15 (10)*3

40–10 ~ +46–15 ~ +24

7.23.7 - 8.8

2.257.24435.7A+

8.63.4 - 10.7

2.287.05.66.24.71.4

25163.9A

18.0

5942.143.050536425

6.35 × 412.7×1+9.52×3

6025

15 (10)*3

40–10 ~ +46–15 ~ +24

8.33.7 - 9.2

2.448.34606.3

A++

9.33.4 - 11.6

2.008.77.17.86.01.6

28844.2A+

21.4

6255.655.649516125

6.35 × 412.7×1+9.52×3

7025

15 (10)*3

25–10 ~ +46–15 ~ +24

10.23.9 - 11.0

3.1510.25376.6

A++

10.54.1 - 14.0

2.348.97.37.96.31.6

29584.2A+

21.4

6365.168.052566525

6.35 × 512.7×1+9.52×4

8025

15 (10)*3

0–10 ~ +46–15 ~ +24

Up to 3 Indoor Units Up to 4 Indoor Units Up to 5 Indoor Units

Up to 6 Indoor Units

Cooling

Heating

Operating Current (max)*5

Outdoor Unit

Ext. Piping

Guaranteed Operating Range [Outdoor]

SourceOutdoor (V/Phase/Hz)Capacity

Input*5

EER*6

Capacity

Input*5

COP*6

DimensionsWeightAir Volume

Sound Level (SPL)

Sound Level (PWL)Breaker SizeDiameter

Total Piping Length (max)Each Indoor Unit Piping Length (max)

Rated

Rated

EEL RankRated

Rated

EEL Rank

H × W × D

CoolingHeatingCooling

CoolingHeating

Liquid

CoolingHeating

kW

kW

Min - Max kW

kWMin - Max kW

kW

A

mmkg

m3/minm3/mindB(A)dB(A)dB(A)

Amm

Gas mmmm

Max. Height mChargeless Length m

oCoC

R410A*1

Outdoor power supply230 / Single / 50

Please refer to (*5)

MXZ-6D122VA

Type (Inverter Multi - Split Heat Pump)Indoor UnitOutdoor UnitRefrigerant

Power Supply

12.23.5 - 13.5

3.663.33

A14.0

3.5 - 16.53.314.23

A26.8

1048 - 950 - 33088

63.077.055576932

6.35 × 612.7×1+9.52×5

8025

15 (10)*3

30–10 ~ +46–15 ~ +24

*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant �uid with a GWP equal to 1975. This means that if 1kg of this refrigerant �uid would be leaked to the atmosphere, the impact on global warming would be 1975 times higher than 1kg of CO2, over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.

*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.*3 If the outdoor unit is installed higher than the indoor unit, max. height is reduced to 10m.*4 EER/COP, EEL rank, SEER/SCOP values and energy e�ciency class are measured

when connected to the indoor units listed below.MXZ-2D33VA MSZ-SF15VA + MSZ-EF18VEMXZ-2D42VA MSZ-EF18VE2 + MSZ-EF25VE2MXZ-2D53VA(H) MSZ-EF18VE2 + MSZ-EF35VE2MXZ-3D54VA2 MSZ-EF18VE2 + MSZ-EF18VE2 + MSZ-EF18VE2MXZ-3D68VA MSZ-EF18VE2 + MSZ-EF25VE2 + MSZ-EF25VE2MXZ-4D72VA MSZ-EF18VE2 + MSZ-EF18VE2 + MSZ-EF18VE2 + MSZ-EF18VE2MXZ-4E83VA MSZ-EF18VE2 + MSZ-EF18VE2 + MSZ-EF22VE2 + MSZ-EF25VE2MXZ-5E102VA MSZ-EF18VE2 + MSZ-EF18VE2 + MSZ-EF22VE2 + MSZ-EF22VE2 + MSZ-EF22VE2

*5 Power input and operating current (max) �gures are for outdoor unit only*6 EER/COP, EEL rank, values and energy e�ciency class are measured

when connected to the indoor units listed below.MXZ-6D122VA MSZ-EF22VE × 6

N: Please refer to the NOTE below.

INVERTER MULTIMXZ SERIES

Please fill out the requested informationPlease fill out the requested information

NOTEWhen connecting the MFZ-KJ series indoor unit(s) to this outdoor unit, charge additional refrigerant according to the instructions in the diagram below.

MXZ-2D33VA

No. ofMFZ-KJ indoor units

Maximum amountof refrigerant

Pipe length (L)~20m

100g additional (Total 1250g)1 unit2 units

1250g

MXZ-2D42VA MXZ-2D53VA MXZ-2D53VAH

No. ofMFZ-KJ indoor units

Maximum amountof refrigerant

Pipe length (L)~20m

100g additional (Total 1400g)200g additional (Total 1500g)

~30m100g+{(L-20)m×20g/m)}200g+{(L-20)m×20g/m)}

1 unit2 units

1600g1700g

MXZ-3D54VA2

No. ofMFZ-KJ indoor units

Maximum amountof refrigerant

Pipe length (L)~40m

100g additional (Total 2800g)200g additional (Total 2900g)300g additional (Total 3000g)

~50m100g+{(L-40)m×20g/m)}200g+{(L-40)m×20g/m)}300g+{(L-40)m×20g/m)}

1 unit2 units3 units

3000g3100g3200g

MXZ-3D68VA MXZ-4D72VA

No. ofMFZ-KJ indoor units

Maximum amountof refrigerant

Pipe length (L)~40m

100g additional (Total 2800g)200g additional (Total 2900g)300g additional (Total 3000g)

~60m100g+{(L-40)m×20g/m)}200g+{(L-40)m×20g/m)}300g+{(L-40)m×20g/m)}

1 unit2 units3 units

3200g3300g3400g

Not available (Only one MFZ-KJ series indoor unit can be connected.)

MSZ-FH

MLZ-KA

MSZ-SF

MSZ-EF

SLZ-KF

MFZ-KJ

4E83-6D 3D-4D72

Number of MFZ-KJ should be one or two when connected to MXZ-4D72VA. If three and more MFZ-KJ are connected, use other outdoor units, such as MXZ-3D68VA and MXZ-4E83VA.