multi v hz r410a)
TRANSCRIPT
For continual product development, LG
reserves the right to change specifications without notice.
©LG
Electronics Inc. Printed in K
orea Decem
ber. 2008 Designed by crim
ad.
2009LG
MU
LTI V Air C
onditioning System
Outdoor Unit
MULTI V MINI MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE II
16202834
Indoor Unit
Wall MountedARTCOOLCeiling CassetteCeiling Concealed DuctCeiling & FloorCeiling SuspendedFloor Standing
49505256606162
& AccessoryNetwork Solution& AccessoryRemote ControllerCentral ControllerAccessory
747684
Heat Recovery VentilatorFeaturesInstallation & MaintenanceLine-upSpecifications
66676870
Enjoy a clean & comfortable life with MULTI V.
2009
Air Conditioning System
http://w
ww.lg
eaircon.com
Air Conditioning System
2009
Air Conditioner20 Yeouido-dong, Yeongdeungpo-gu,Yeouido P.O.Box 335 Seoul, 150-721, Korea.Phone : +82-2-3777 -7998 Fax : +82-2-3777- 5136
http://www.lgeaircon.com
Distributed by
EU-MV091
10
38
64
72
Pyeongtaek in KoreaChangwon in Korea Thailand England France Australia Moscow Singapore
Spain Italy Dubai China Saudi Arabia Mexico Panama Indonesia Iran Turkey Vietnam
Global Air Conditioning Academies
Life’s Good! Frominstallationtomaintenanceandrepair,
LGruns30globalairconditioningacademies,providing
trainingforairconditioningprofessionalsaroundtheworld.
Establishment1947 EstablishmentoftheLGGroup1958 EstablishmentofLGElectronicsInc.
1962 EstablishmentofDigitalApplianceCompany
Growth1968 ManufacturedKorea’sfirstairconditioners1985 IntroducedKorea’sfirstInverterairconditioners1986 ExportedKorea’sfirstwindowtypeairconditioner
Expansion1995 EstablishmentofLGETAinChina1997 EstablishmentofLGEILinIndia1999 EstablishmentofLGEATinTurkey1999 EstablishmentofLGEVNinVietnam2001 EstablishmentofLGEAZinBrazil2002 EstablishmentofLGETHinThailand2002 EstablishmentofLGEINinIndonesia2004 TurnoverofUS$1.4Billiondollars2008 EstablishmentofLGELFinLevantCountries2008 EstablishmentofLGETKinTurkey
B r i e f H i s t o r y
Yourlifecomesmorequiet,economicalandpowerfulwithLGairconditioninghightechnology.
Multi V Series
Environment
Economic
Easy Design & Installation
Engineering Support Indoor
Unit WallMountedARTCOOLCeilingCassetteCeilingConcealedDuctCeiling&FloorCeilingSuspendedFloorStanding
49505256606162
38
Outdoor Unit MULTIVMINI
MULTIVPLUSIIMULTIVSYNCIIMULTIVSPACEII
16202834
10
eco V(Heat Recovery Ventilator)
FeaturesInstallation&MaintenanceLine-upSpecifications
6667687064
V-net&Accessory
RemoteControllerCentralControllerAccessory
747684
72
LG A
ir Conditioners System
06
_0
7M
ULTI V_
Outdoor unit Line up
Outdoor unit line up
HPMODEL 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64
*3Ø, 380V*1Ø, 220V
LG A
ir Conditioners System
08
_0
9M
ULTI V_
Indoor unit Line up
Mirror
2way Cassette
1way Cassette
Low Static
Built-in
High Static
With Case
Without Case
Indoor unit line up
kW
Btu / h 18k 24k 28k 36k 42k 48k 76k 96k7k 9k 12k 15k
5.6 7.1 8.2 10.6 12.3 14.1 22.4 28.02.2 2.8 3.6 4.5
Series
Ceiling Cassette
Ceiling Concealed Duct
Floor Standing
Ceiling & Floor
Ceiling Suspended
SRAC Wall Mounted
(840*840)4way Cassette
(570*570)4way Cassette
5k
1.5
LG A
ir Conditioners System
10_
11O
utdoor Unit_
MU
LTI V series
MULTIVInverterunitscomposedofseriallyarrangedrefrigerantpipesconnectedtoasingleoutdoorunitareanefficientsystemthatoffersoutstandingenergysaving,simpleandeasyinstallation,andconnectiontodifferenttypesofindoorunits,makingiteasytodesignandinstall.
Outdoor unit
MULTIVMINI
MULTIVPLUSII
MULTIVSYNCII
MULTIVSPACEII
16
20
28
34
M U LT I V o u t d o o r
04
01
LG A
ir Conditioners System
12_13
Outdoor U
nit_M
ULTI V series
DCInverterCompressor
Oilinjectionmechanism- High reliability in low rpm operation- High efficiency in partial load operation
02
Oildischargereduction- High reliability in high rpm operation- Enhanced oil circulation
03
05
06
Tefloncoatedbearing
Highperformanceoilpump
Optimizedscrollshape
DCInvertermotor - High efficiency - Low noise
WorldHighestCOP!•DCInvertercompressor
•Invertercombination
•HighefficientDCInverterfan
•Widelouverheatexchanger
*Basedon10HPmodel
Inverter
ACompany
DC Inverter Compressor
Constant Speed Compressor
*25~105Hz
OtherFeaturesDCInverterfanmotor- Max RPM increased from 850 to 920 rpm - Power consumption decreased by 30~40%
01
UpgradedMainPCB
- 3-Digit 7 segment
- Double DIP switch
Main PCB
02
03
04
Widelouverheatexchanger- Improved heat exchange rate by 14%- Anti-corrosion treatment (Gold fin)
Blackboxfunction- Save the last 3 minutes operating data- Precise analysis & fast trouble-shooting
01
02
03 04
Corrugate fin
Widelouverfin
WideLouverheatexchanger
Inverter InverterInverterCombination•Increasedperformance&highCOP
•Fasterresponseforpartialload
•Optimizedcombinationwithspacesaving
•Competitivepriceforcustomers
•Reducedtotalbasemodelunits - Simple line-up (16 models > 5 models) - Easy stock & logistics management
3ØINVcontroller
Total piping length 1000m
ExtendedPipingLength•MULTIVPLUSII/SYNCII
•Refertothespecificationsformoreinformation
1stbranchtofarthestIndoor40m[90m**]Level
difference100m
Longestpipinglength150m(200m**)
•MULTIVPLUSII,MULTIVSYNCII
15m
*UsingYbranch
Pursuingthemarketneedsofhighenergyefficiencyandenvironmentalfriendliness.
Outdoor unitMULTIVMINI/MULTIVPLUSIIMULTIVSYNCII/MULTIVSPACEII
2009NewFeatures
** Conditional Application To make 40~90m of pipe length after first branch, refer to the part of “installation of outdoor units” in PDB
1000m
150m(200m**)
40m[90m**]
100m
15m
5m
Totalpipinglength
Longestpipinglength
Longestpipinglengthafter1stbranch
LeveldifferencebetweenODU~IDU
LeveldifferencebetweenIDU~IDU
LeveldifferencebetweenODU~ODU
05
06
01
04
03
02
LG A
ir Conditioners System
14_
15O
utdoor Unit_
MU
LTI V series
Enhanced comfort for end-user!
* Based on MULTI V PLUS II, 10HP model
Night Silent OperationNight silent operation will be on for X hours starting from the peak temperature during daytime, and then after Y hours, it’ll be back to normal operation. - Mode 1 > X : 8.0 hours, Y : 9.0 hours - Mode 2 > X : 6.5 hours, Y : 10.5 hours - Mode 3 > X : 5.0 hours, Y : 12.0 hours
Each mode can be selected as 3 steps of sound level.
LG MV • Easy start-up, easy trouble shooting
• Monitoring the normality of all parts such as compressor, fan, valve, etc
• Operation state • Central Controller • Cycle view
Command
Sensor reading
LATS MULTI V • Convenient model selection program
• Highly user-friendly design (Autocad version)
• Automatic piping design & check
Download from sales supporting system> http://www.lgeaircon.com
• Model selection • Auto check
• CAD application • Making quotation
Pursuing the market needs of high energy efficiency and environmental friendliness.
Outdoor unit
Unit : dBA
MINI PLUS II SYNC IIStep 1Step 2Step 3
46
43
40
47
44
41
47
44
41
MULTI V MINI / MULTI V PLUS II MULTI V SYNC II / MULTI V SPACE II
2009 New Features
Automatic Refrigerant Charging• Refrigerant charging without any scales or quantity calculation
• This function is recommended during service.
• Guaranteed temperature range : IDU(20~32˚C), ODU(0~43˚C)
• FDD function (Fault detect & diagnosis)
Manifold
Refrigerant charging kit
Refrigerant
* Fault detect & diagnosis
Automatic Refrigerant Check-Up• It can be checked refrigerant status during start-up whether it is undercharged or overcharged
• It can be decided appropriate amount of refrigerant automatically through cycle operation.
• FDD function (Fault detect & diagnosis)
Leakage!
Leakage!
Leakage!
Leakage!
* Fault detect & diagnosis
LG A
ir Conditioners System
16_
17O
utdoor Unit_
MU
LTI V MIN
I
EFFICIENCYMULTI V MINI uses the cutting-edge, artificial intelligence control to obtain efficient operation and reduced noise.
MULTI V MINI can be easily installed in small offices
and shops. Designed for low-noise operation,
it ensures a pleasant air conditioned environment.
Enjoy a clean & comfortable life with MULTI V MINI.
Day time Night time(Based on 4HP)
• Noise level (dBA)
Slim & Compact SizeEasy & efficient installation of MULTI V MINI will provide the best solution for small offices and shops.
4, 5, 6 HP5, 6 HP
• Foot print area
806mm
730mm
330mm
950mm
46%Reduction
• Volume
52%Reduction
WxHxD : 806×1607×730 WxHxD : 950x1380x330
Conventional
50 51 52
4HP 5HP 6HP STEP 1 STEP 2 STEP 3
404346
Enhanced Comfort• Night silent operation
• High COP
• Longest Piping Length
Cooling Heating Cooling Heating
4HP5HP6HP
1Ø, 220V 3Ø, 380V
3.93.73.6
4.04.03.8
3.73.63.5
3.93.93.8
Total piping length
Longest piping length (Equivalent)
Longest piping length after 1st branch
Level difference between ODU~IDU
Level difference between IDU~IDU
Level difference between ODU~ODU
300m
150m(175m)
40m
50m(40m*)
15m
5m
*Outdoor unit is lower than indoor unit.
11.212.52.93.1
3.864.03
950 x 1380 x 330118
5052
110
1
3.7
FV50S[PVE] 1.7
Ø9.52(3/8)Ø15.88(5/8)
16
15.518.04.34.7
3.603.83
950 x 1380 x 330118
5254
110 1
3.7
FV50S[PVE] 1.7
Ø9.52(3/8)Ø19.05(3/4)
19
14.016.03.84.0
3.684.00
1, 220 ~ 240, 50950 x 1380 x 330
118
5153
110 1
3.7
FV50S[PVE] 1.7
Ø9.52(3/8)Ø15.88(5/8)
18
LG A
ir Conditioners System
18_
19O
utdoor Unit_
MU
LTI V MIN
I
Max. 9 Indoor Units ConnectableMaximum 9 indoor units can be connected to one single outdoor unit with 130% indoor unit combination.
- 9 indoor units for 6HP - 8 indoor units for 5HP - 6 indoor units for 4HP
Easy to Service
Inner SVC valve- 4 Way piping is possible (Front, Rear, Right, Down)
- Excellent exterior
01
Convenient moving handle02
units
*Based on 6 HP model
54321
876 9
1 Way 4 Way
Compact design & Easy service- Remove 3 pieces of screw for SVC- Front panel removal system
03
• DC Inverter Compressor & Fan motor
• Black Box Function
• Night Silent Operation
• Fault Detect & Diagnosis
• Pump Down
‘09 New Feature
3 pieces of screw
Easy service
MULTI V MINI can be easily installed in small offices
and shops. Designed for low-noise operation,
it ensures a pleasant air conditioned environment.
* Specifications
Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling HeatingPower Supply Ø, V, HzDimensions(WxHxD) mmWeight kgColorNoise level Cooling dBA±3 Heating dBA±3Fan Type Air flow rate [CMM]Compressor Type Number of compressorsHeat ExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping Liquid Pipes mm(inch)Connections Gas Pipes mm(inch)Number of outdoor unitNumber of maximum connectable indoor units
HP
Model 4
Ratio of the connectable indoor unitsLongest piping length / Level difference
65
EEV
Gold FinR410A
DC INVERTER
BLDC
Warm Gray
5 64
14.016.03.94.1
3.593.90
3, 380 ~ 415, 50950 x 1380 x 330
112
5153
110 1
3.7
FV50S[PVE] 1.3
Ø9.52(3/8)Ø15.88(5/8)
18
11.212.53.03.2
3.733.91
950 x 1380 x 330
112
5052
110
1
3.7
FV50S[PVE] 1.3
Ø9.52(3/8)Ø15.88(5/8)
16
15.518.0 4.44.8
3.523.75
950 x 1380 x 330
112
52 54
110 1
3.7
FV50S[PVE] 1.3
Ø9.52(3/8)Ø19.05(3/4)
19
EEV
Gold FinR410A
DC INVERTER
BLDC
Warm Gray
Independent Unit ARUN40GS2 ARUN60GS2ARUN50GS2 ARUN40LS2 ARUN60LS2ARUN50LS2
*1Ø, 220V *3Ø, 380V
150m/50m50~130%
150m/50m50~130%
Note :
1. Capacities are based on the following conditions Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB
Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5m Interconnecting piping length 7.5mLevel difference of zero Level difference of zero
2. Capacities are net capacities3. Due to our policy of innovation some specifications may be changed without notification4. EEV : Electronic Expansion Valve
02
01
03
LG A
ir Conditioners System
20_
21O
utdoor Unit_
MU
LTI V PLUS II
TECHNOLOGYYourlifewillbeupgradedthroughthestate-of-the-arttechnologyofMULTIVPLUSII.
Enjoyaclean&comfortablelifewithMULTIV.
*Based on 10HP model
Rear57dB
Side52dB
Front58dB
Alternate-CyclingFunction• Toextendcompressors’lifespanbyoperatingthemalternately
InverterA<>InverterB<>InverterC
ConstantA<>ConstantB<>ConstantC
• Tomeetdiverseloadinoperation
ON ON ON ON ON
InverterA
ConstantA
InverterB
ConstantB
InverterC
ConstantC
MULTIVInvertersystemoffersoneoftheworld’s
largestcapacityunits,essentialforhigh-risebuildings.
Weareproudtosaythesystemwillensurethehighest
levelofcustomersatisfaction.
ODU Noise Comparison
505 10 20 30 40
55
60
65
dBA
HP
70
Gernerally lower noise!!
LG Competitor
LowNoise• Latesttechnologyandfeaturesareappliedtothenewoutdoorunitstoreducenoiselevel.
LG A
ir Conditioners System
22_23
Outdoor U
nit_M
ULTI V PLU
S II
CONVENIENCEFrom installation and transportation to maintenance and service, MULTI V PLUS II adds convenience to cutting-edge technology.
• Pump down
Refrigerant flow
Repair! Repair! Repair!
• Pump out
Refrigerant flow
Reftigerant flow
Failed!
Pump Down & Pump Out• Pump down When indoor units need to replace, refrigerant can be collected to the outdoor unit. - MULTI V MINI / PLUS II / SYNC II / SPACE II
• Pump out If left outdoor unit breakdown, refrigerant can be sent to another outdoor and indoor unit during service. - MULTI V PLUS II / SYNC II
Auto addressingAddressing outdoor units and indoor units are automatically done just by pressing the button.
Automatic Back-Up• For emergency, it makes back-up operation possible before trouble-shooting
Inverter A, B + Constant B > Inverter B + Constant A, B
• Error notice in indoor unit : 4 times per day (every 6 hour)
Plate Type SC HEX• Increased sub-cooling by high- performance heat exchanger
• Enable to be long piping length and level difference
• More powerful cooling operation
Double tube
Plate SC
Non-Polarity Transmission ConnectionEasy installation and no errors for transmission line connections
* Combination possible model only
Wired remote control
Wired remote control
Wired remote control
Indoor unit Indoor unit Indoor unit
Cool / Heat Selector• Control all units without any central controller installed
• Select operation mode (Air circulation, cooling, heating)
• Mode lock for heating & cooling mixing error-proof during the change of season
Mode change
Heating
Fan mode
Cooling
MULTI V Inverter system offers one of the world’s
largest capacity units, essential for high-rise buildings.
We are proud to say the system will ensure the highest
level of customer satisfaction.
ONFailed
InverterA
ConstantA
InverterB
ConstantB
ONONON
InverterA
ConstantA
InverterB
ConstantB
ONON
• • •3 4A 3 4
B
> or > or
43 43> or > or
Indoorunit 1
Outdoorunit
Indoorunit 2
43 43 43
• • •Indoor unit 1 Indoor unit 2
E F
Outdoorunit
B
Indoorunit
Outdoor unit control box
DC
Central controller
A Dry1 Dry2
Dry contact
GND 12V
Central controller
43
LG A
ir Conditioners System
24_
25O
utdoor Unit_
MU
LTI V PLUS II
SeparateFrontPanel•EasyaccesstomainPCB(DIPswitch)
•Convenientduringserviceandstart-up
•Benefitsfortechnician,installer
Close Open
OtherFeatures•Resistanttodust,rain,corrosionandothers
•Convenientmaintenanceduetoswingdoortypecontrolbox
•Easytohandlethroughforkliftslot
•Strongbase-pansupport
•Safetychassis •Swingcontrolbox
•Easytohandle •Strongbase-pan
•DCInverterCompressor&Fanmotor
•BlackBoxFunction
•NightSilentOperation
•FaultDetect&Diagnosis
•PumpDown&PumpOut
‘09NewFeature
Checkupthenote,refertoonthe27page.
* Specifications5 6 16141210
ARUN60LT2ARUN60LT2
ARUN100LT2ARUN100LT2
ARUN120LT2ARUN120LT2
ARUN140LT2ARUN140LT2
ARUN160LT2ARUN160LT2
ARUN80LT2ARUN80LT2
8HPModel Combinationunit Independentunit
Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling HeatingPowerSupply Ø,V,HzDimensions(WxHxD) mmWeight kgColorNoiselevel dBA±3Fan Type Airflowrate [CMM]Compressor Type NumberofcompressorsHeatExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping LiquidPipes mm(inch)Connections GasPipes mm(inch)NumberofoutdoorunitNumberofmaximumconnectableindoorunits*
14.0
15.8
3.75
4.00
3.73
3.95
3, 380~415, 50
806×1607×730
175
56
105
1
4.5
2.3
Ø9.52(3/8)
Ø15.88(5/8)
1
8(12)
44.8
50.4
14.00
12.40
3.20
4.06
3, 380~415, 50
1280×1607×730
285
58
190
2
8
5.6
Ø12.7(1/2)
Ø28.58(1 1/8)
1
26(40)
39.2
44.1
11.85
10.60
3.31
4.16
3, 380~415, 50
1280×1607×730
285
58
190
2
8
5.6
Ø12.7(1/2)
Ø28.58(1 1/8)
1
23(35)
33.6
37.8
9.08
9.05
3.70
4.18
3, 380~415, 50
1280×1607×730
285
58
190
2
8
5.6
Ø12.7(1/2)
Ø28.58(1 1/8)
1
19(30)
28.0
31.5
7.16
7.33
3.91
4.30
3, 380~415, 50
1280×1607×730
285
58
190
2
8
EEV
5.6
Ø9.52(3/8)
Ø22.2(7/8)
1
16(25)
16.0
18.0
4.25
4.55
3.76
3.96
3, 380~415, 50
806×1607×730
175
56
105
1
4.5
2.3
Ø9.52(3/8)
Ø19.05(3/4)
1
9(14)
22.4
25.2
5.28
5.73
4.24
4.40
3, 380~415, 50
1280×1607×730
240
58
190
1
8
3.3
Ø9.52(3/8)
Ø19.05(3/4)
1
13(20)
ARUN50LT2ARUN50LT2
DC Inverter Scroll
Propeller Fan (DC INV)
Warm Gray
Gold finR410A
RatiooftheconnectableindoorunitsLongestpipinglength/Leveldifference**
50~200%
200m/100m
FVC68D(PVE)
MULTIVInvertersystemoffersoneoftheworld’s
largestcapacityunits,essentialforhigh-risebuildings.
Weareproudtosaythesystemwillensurethehighest
levelofcustomersatisfaction.
DC Inverter Scroll / Constant speed Scroll
LG A
ir Conditioners System
26_
27O
utdoor Unit_
MU
LTI V PLUS II
* Specifications
ARUN180LT2ARUN120LT2ARUN60LT2
20 22 24 26 28 30 32ARUN320LT2ARUN160LT2ARUN160LT2
ARUN300LT2ARUN160LT2ARUN140LT2
ARUN280LT2ARUN140LT2ARUN140LT2
ARUN260LT2ARUN140LT2ARUN120LT2
ARUN240LT2ARUN160LT2ARUN80LT2
ARUN220LT2ARUN160LT2ARUN60LT2
ARUN200LT2ARUN140LT2ARUN60LT2
18HPModel Combinationunit Independentunit
Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling HeatingPowerSupply Ø,V,HzDimensions(WxHxD) mm
Weight kgColorNoiselevel dBA±3Fan Type Airflowrate [CMM]Compressor Type NumberofcompressorsHeatExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping LiquidPipes mm(inch)Connections GasPipes mm(inch)NumberofoutdoorunitNumberofmaximumconnectableindoorunits*
89.6
100.8
28.00
24.80
3.20
4.06
3, 380~415, 50
(1280×1607×730)×2
285x2
61
380
4
8+8
5.6x2
Ø19.05(3/4)
Ø34.9(1 3/8)
2
52(64)
84.0
94.5
25.85
23.00
3.25
4.11
3, 380~415, 50
(1280×1607×730)×2
285x2
61
380
4
8+8
5.6x2
Ø19.05(3/4)
Ø34.9(1 3/8)
2
49(60)
78.4
88.2
23.70
21.20
3.31
4.16
3, 380~415, 50
(1280×1607×730)×2
285x2
61
380
4
8+8
5.6x2
Ø19.05(3/4)
Ø34.9(1 3/8)
2
45(56)
72.8
81.9
20.93
19.65
3.48
4.17
3, 380~415, 50
(1280×1607×730)×2
285x2
61
380
4
8+8
5.6x2
Ø19.05(3/4)
Ø34.9(1 3/8)
2
42(52)
67.2
75.6
19.28
18.13
3.49
4.17
3, 380~415, 50
(1280×1607×730)×2
285+240
61
380
3
8+8
5.6+3.3
Ø15.88(5/8)
Ø34.9(1 3/8)
2
39(48)
61.6
69.3
18.25
16.95
3.38
4.09
3, 380~415, 50
(1280×1607×730)
+(806×1607×730)
285+175
60
295
3
4.5+8
5.6+2.3
Ø15.88(5/8)
Ø28.58(1 1/8)
2
35(44)
56.0
63.0
16.10
15.15
3.48
4.16
3, 380~415, 50
(1280×1607×730)
+(806×1607×730)
285+175
60
295
3
4.5+8
5.6+2.3
Ø15.88(5/8)
Ø28.58(1 1/8)
2
32(40)
50.4
56.7
13.33
13.60
3.78
4.17
3, 380~415, 50
(1280×1607×730)
+(806×1607×730)
285+175
60
295
3
4.5+8
5.6+2.3
Ø15.88(5/8)
Ø28.58(1 1/8)
2
29(36)
Warm Gray
Propeller Fan(DC INV)
DC Inverter Scroll / Constant speed Scroll
Gold fin
R410A
RatiooftheconnectableindoorunitsLongestpipinglength/Leveldifference**
50~160%
200m/100m
FVC68D(PVE)
MULTI V PLUS II ensures economic life with high energy efficiency!!
* Specifications50HP
Model Combinationunit Independentunit
Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling HeatingPowerSupply Ø,V,HzDimensions(WxHxD) mmWeight kgColorNoiselevel dBA±3Fan Type Airflowrate [CMM]Compressor Type NumberofcompressorsHeatExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping LiquidPipes mm(inch)Connections GasPipes mm(inch)NumberofoutdoorunitNumberofmaximumconnectableindoorunits
140
157.5
40.83
37.53
3.43
4.20
3, 380~415, 50
(1280x1607x730)x4
285X3+240
64
760
7
8+8+8+8
5.6X3+3.3
Ø19.05(3/4)
Ø41.3(1 5/8)
4
64
145.6
163.8
42.98
39.33
3.39
4.16
3, 380~415, 50
(1280x1607x730)x4
285X3+240
64
760
7
8+8+8+8
5.6X3+3.3
Ø19.05(3/4)
Ø41.3(1 5/8)
4
64
151.2
170.1
45.13
41.13
3.35
4.14
3, 380~415, 50
(1280x1607x730)x4
285X3+240
64
760
7
8+8+8+8
5.6X3+3.3
Ø19.05(3/4)
Ø41.3(1 5/8)
4
64
156.8
176.4
47.28
42.93
3.32
4.11
3, 380~415, 50
(1280x1607x730)x4
285X3+240
64
760
7
8+8+8+8
5.6X3+3.3
Ø19.05(3/4)
Ø41.3(1 5/8)
4
64
162.4
182.7
49.16
44.53
3.30
4.10
3, 380~415, 50
(1280x1607x730)x4
285x4
64
760
8
8+8+8+8
5.6x4
Ø19.05(3/4)
Ø41.3(1 5/8)
4
64
168
189
51.08
46.25
3.29
4.09
3, 380~415, 50
(1280x1607x730)x4
285x4
64
760
8
8+8+8+8
5.6x4
Ø19.05(3/4)
Ø41.3(1 5/8)
4
64
173.6
195.3
53.85
47.80
3.22
4.09
3, 380~415, 50
(1280x1607x730)x4
285x4
64
760
8
8+8+8+8
5.6x4
Ø19.05(3/4)
Ø41.3(1 5/8)
4
64
179.2
201.6
56.00
49.60
3.20
4.06
3, 380~415, 50
(1280x1607x730)x4
285x4
64
760
8
8+8+8+8
5.6x4
Ø19.05(3/4)
Ø41.3(1 5/8)
4
64
52 54 56 58 60 62 64ARUN500LT2ARUN140LT2ARUN140LT2ARUN140LT2ARUN80LT2
RatiooftheconnectableindoorunitsLongestpipinglength/Leveldifference**
50~130%
200m/100m
Warm Gray
Propeller Fan(DC INV)
DC Inverter Scroll / Constant speed Scroll
Gold finR410A
ARUN520LT2ARUN160LT2ARUN140LT2ARUN140LT2ARUN80LT2
ARUN540LT2ARUN160LT2ARUN160LT2ARUN140LT2ARUN80LT2
ARUN560LT2ARUN160LT2ARUN160LT2ARUN160LT2ARUN80LT2
ARUN580LT2ARUN160LT2ARUN160LT2ARUN160LT2ARUN100LT2
ARUN600LT2ARUN160LT2ARUN160LT2ARUN160LT2ARUN120LT2
ARUN620LT2ARUN160LT2ARUN160LT2ARUN160LT2ARUN140LT2
ARUN640LT2ARUN160LT2ARUN160LT2ARUN160LT2ARUN160LT2
FVC68D(PVE)
34ARUN340LT2ARUN140LT2ARUN140LT2ARUN60LT2
ARUN360LT2ARUN160LT2ARUN140LT2ARUN60LT2
ARUN380LT2ARUN160LT2ARUN160LT2ARUN60LT2
ARUN400LT2ARUN160LT2ARUN160LT2ARUN80LT2
ARUN420LT2ARUN140LT2ARUN140LT2ARUN140LT2
ARUN440LT2ARUN160LT2ARUN140LT2ARUN140LT2
ARUN460LT2ARUN160LT2ARUN160LT2ARUN140LT2
ARUN480LT2ARUN160LT2ARUN160LT2ARUN160LT2
48464442403836HPModel Combinationunit Independentunit
Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling HeatingPowerSupply Ø,V,HzDimensions(WxHxD) mm
Weight kgColorNoiselevel dBA±3Fan Type Airflowrate [CMM]Compressor Type NumberofcompressorsHeatExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping LiquidPipes mm(inch)Connections GasPipes mm(inch)NumberofoutdoorunitNumberofmaximumconnectableindoorunits
95.2
107.1
27.95
25.75
3.41
4.16
3, 380~415, 50
(1280×1607×730)×2
+(806×1607×730)
285x2+175
62
485
5
4.5+8+8
5.6x2+2.3
Ø19.05(3/4)
Ø34.9(1 3/8)
3
55
100.8
113.4
30.10
27.55
3.35
4.12
3, 380~415, 50
(1280×1607×730)×2
+(806×1607×730)
285x2+175
62
485
5
4.5+8+8
5.6x2+2.3
Ø19.05(3/4)
Ø41.3(1 5/8)
3
58
106.4
119.7
32.25
29.35
3.30
4.08
3, 380~415, 50
(1280×1607×730)×2
+(806×1607×730)
285x2+175
62
485
5
4.5+8+8
5.6x2+2.3
Ø19.05(3/4)
Ø41.3(1 5/8)
3
61
112.0
126.0
33.28
30.53
3.37
4.13
3, 380~415, 50
(1280×1607×730)×3
285x2+240
63
570
5
8+8+8
5.6x2+3.3
Ø19.05(3/4)
Ø41.3(1 5/8)
3
64
117.6
132.3
35.55
31.80
3.31
4.16
3, 380~415, 50
(1280×1607×730)×3
285×3
63
570
6
8+8+8
5.6x3
Ø19.05(3/4)
Ø41.3(1 5/8)
3
64
123.2
138.6
37.70
33.60
3.27
4.13
3, 380~415, 50
(1280×1607×730)×3
285×3
63
570
6
8+8+8
5.6x3
Ø19.05(3/4)
Ø41.3(1 5/8)
3
64
128.8
144.9
39.85
35.40
3.23
4.09
3, 380~415, 50
(1280×1607×730)×3
285×3
63
570
6
8+8+8
5.6x3
Ø19.05(3/4)
Ø41.3(1 5/8)
3
64
134.4
151.2
42.00
37.20
3.20
4.06
3, 380~415, 50
(1280×1607×730)×3
285×3
63
570
6
8+8+8
5.6x3
Ø19.05(3/4)
Ø41.3(1 5/8)
3
64
Warm Gray
Propeller Fan(DC INV)
DC Inverter Scroll / Constant speed Scroll
Gold finR410A
RatiooftheconnectableindoorunitsLongestpipinglength/Leveldifference**
50~130%200m/100m
FVC68D(PVE)
EEVEEV
EEV
• A combination operation over 100% cause to reduce each indoor unit capacity
•Combinationratio(50~200%)
No. of outdoor unit Connection CapacitySingle unit 200%Double unit 160%Triple unit 130%Over triple unit 130%
CAUTION
We can guarantee the operation only within 130% Combination.If you want to connect more than 130% combination, please contact us and discuss the requirement like below.
1) If the operation of indoor unit is more than 130%, low airflow operation is recommended in all the indoor units. 2) If the operation of indoor unit is more than 130%, additional refrigerant is needed according to the headquarter guidance. 3) Over 130%, capacity is same as capacity of 130%, Same remark is valid for power input.
1.Capacitiesarebasedonthefollowingconditions Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB
Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5m Interconnecting piping length 7.5mLevel difference of zero Level difference of zero
2.Capacitiesarenetcapacities3.Duetoourpolicyofinnovationsomespecificationsmaybechangedwithoutnotification4.EEV:ElectronicExpansionValve
**ConditionalApplicationTomake40~90mofpipelengthafterfirstbranchrefertothepartof“installationofoutdoorunits”inPDB
*Thenumberof()meansthenumberofmax.connectableindoorunits,whentheconnectedcapacityofindoorunitsisinthetable below.
Note:
LG A
ir Conditioners System
28_
29O
utdoor Unit_
MU
LTI V SYNC II
TECHNOLOGYYour life will be upgraded through the state-of-the-art technology of MULTI V SYNC II.
Heating & Cooling Synchronous Operation• High COP up to 6.3 - When, cooling(40%) + heating(60%)
• Energy consumption can be decreased by 30%
Simultaneous heating and cooling with one outdoor
unit, MULTI V SYNC II. Your environment is ensured of
optimum conditions regardless of season or space.
Enjoy a clean & comfortable life with MULTI V.
Cooling <
> Cooling
> Heating
Heating <
Heating Cooling
Office
Long Piping Length• MULTI V SYNC II
• Refer to the specifications for more information• MULTI V SYNC II
15m
AMC (Advanced Mode Change)
AMC control provides an optimal cycleoperation under any conditions.
- Real time pressure control- Optimal cycle in optimum area- Needed time to change mode : Max. 3min
Wide Operation Range
Wide operation range- Heating mode : - 20°C WB ~ 16°C WB- Cooling mode : - 5°C DB ~ 43°C DB- Synchronous mode : -10°C DB ~ 27°C DB
Heating
Cooling
SynchronousOperation area
1000m
150m(200m**)
40m[90m**]
100m
15m
5m
** Conditional application To make 40~90m of pipe length after first branch, refer to the part of “installation of outdoor units” in PDB
1st branch to farthest indoor 40[90m**]
Longest piping length 150(200m**)
Total piping length 1000m
Level difference
100m
Total piping length
Longest piping length
Longest piping length after 1st branch
Level difference between ODU~IDU
Level difference between IDU~IDU
Level difference between ODU~ODU
Equipment room
40
* Outdoor temperature : 7°C DB / 6°C WB
* Indoor temperature : 20°C DB / 15°C WB
Max. COP (6.3)
Coe
ffic
ient
of P
erfo
rman
ce(C
OP
)
Heating operation ratio (%)
Optimum area
LG A
ir Conditioners System
30_
31O
utdoor Unit_
MU
LTI V SYNC II
FastResponseofModeChangeWhentheuserwantstochangetheindoorunit’soperatingmode(ex.cooling>heating),MULTIVSYNCIItakeslesstimecomparedtotheconventional.Thisfastresponseofmodechangeprovidesamorepleasantandcomfortableairconditioning.
•MULTIVSYNCII
•Conventional
Max. 3minutes
Heating Cooling
About 20minutes
Heating Cooling
ExcellentMultipleHRUnitLG’sHRunitprovidestheflexibleandconvenientinstallationwithlowercost.
LGneedslessinstallationcostthantheconventional
Ybranch
HRunit
Totalpipinglength
12unit
5unit
690m
57unit
20unit
840m
LG Conventional
*Assumedwith5storiesbuilding
•MULTIVSYNCII •Conventional
15m
20m
3PipingHRunit
2PipingHRunit
2Piping
3Piping
YBranch
COMFORTMULTIVSYNCIIensuresthecomfortofalluserswithflexibledesignandeasyinstallation.
HighEfficiencyHeatRecoveryUnit•HighefficientdoublespiraltubetypeSCIcircuit
•Maximum4indoorunitsconnectableperoneHRunit
•Easyinstallationwithautopipingdetectfunction
From outdoor
Toindoor
2 phase fluid
Linear expansion valve
•Doublespiraltubeheatexchanger
PRHR020 PRHR030 PRHR040
FlexibleConnectionofHRUnitLG’sheatrecoveryunitallowsflexibleconnectionbothinseriesandinarow.
•MULTIVSYNCII
LG unique LG unique
Inseries
•Conventional
Impossible
Impossible
Inseriesonly
Ybranchonly
AutoChangeoverAutochangeoverautomaticallychangeoperatingmodecoolandheat,tomaintainoptimumroomtemperature,sononeedofchangingthemodeduringthechangeofseason.
ConvenientFreeZoningMULTIVSYNCIIprovidesperfectindividualzoningineachroomsfortheuser’sconvenience.
•MULTIVSYNCII •Conventional
Free zoning! Inconvenient zoning!
Samemodeoperationinthedifferentzones
Temp
Time
Changepoint(Heat>Cool)
Changepoint(Cool>Heat)
+∆T
-∆T
Simultaneousheatingandcoolingwithoneoutdoor
unit,MULTIVSYNCII.Yourenvironmentisensuredof
optimumconditionsregardlessofseasonorspace.
LG A
ir Conditioners System
32_33
Outdoor U
nit_M
ULTI V SYN
C II
•DCInverterCompressor&Fanmotor
•BlackBoxFunction
•NightSilentOperation
•FaultDetect&Diagnosis
•PumpDown&PumpOut
‘09NewFeatureMULTI V SYNC II simultaneous heating and cooling from a single outdoor unit!
36HPModel Combinationunit Independentunit
Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling HeatingPowerSupply Ø,V,HzDimensions(WxHxD) mmWeight kgColorNoiselevel dBA±3Fan Type Airflowrate [CMM]Compressor Type NumberofcompressorsHeatExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping Liquid(flare) mm(inch)Connections SuctionGas mm(inch) DischargeGas mm(inch)NumberofoutdoorunitNumberofmaximumconnectableindoorunits
40 464442 48
100.8
113.4
28.98
26.93
3.48
4.21
3, 380~415, 50
(1280x1607x730)x3
240+285+285
63
570
5
8+8+8
5.6+5.6+3.3
Ø19.05(3/4)
Ø41.3(1 5/8)
Ø28.58(1 1/8)
3
58
112.0
126.0
33.28
30.53
3.37
4.13
3, 380~415, 50
(1280x1607x730)x3
240+285+285
63
570
5
8+8+8
5.6+5.6+3.3
Ø19.05(3/4)
Ø41.3(1 5/8)
Ø34.9(1 3/8)
3
64
117.6
132.3
35.16
32.13
3.34
4.12
3, 380~415, 50
(1280x1607x730)x3
285+285+285
63
570
6
8+8+8
EEV
FVC68D(PVE)
5.6+5.6+5.6
Ø19.05(3/4)
Ø41.3(1 5/8)
Ø34.9(1 3/8)
3
64
123.2
138.6
37.7
33.6
3.27
4.13
3, 380~415, 50
(1280x1607x730)x3
285+285+285
63
570
6
8+8+8
5.6+5.6+5.6
Ø19.05(3/4)
Ø41.3(1 5/8)
Ø34.9(1 3/8)
3
64
128.8
144.9
39.85
35.40
3.23
4.09
3, 380~415, 50
(1280x1607x730)x3
285+285+285
63
570
6
8+8+8
5.6+5.6+5.6
Ø19.05(3/4)
Ø41.3(1 5/8)
Ø34.9(1 3/8)
3
64
134.4
151.2
42.0
37.2
3.20
4.06
3, 380~415, 50
(1280x1607x730)x3
285+285+285
63
570
6
8+8+8
5.6+5.6+5.6
Ø19.05(3/4)
Ø41.3(1 5/8)
Ø34.9(1 3/8)
3
64
106.4
119.7
31.13
28.73
3.42
4.17
3, 380~415, 50
(1280x1607x730)x3
240+285+285
63
570
5
8+8+8
5.6+5.6+3.3
Ø19.05(3/4)
Ø41.3(1 5/8)
Ø34.9(1 3/8)
3
61
38ARUB360LT2ARUB140LT2ARUB140LT2ARUB80LT2
ARUB380LT2ARUB160LT2ARUB140LT2ARUB80LT2
ARUB400LT2ARUB160LT2ARUB160LT2ARUB80LT2
ARUB420LT2ARUB160LT2ARUB160LT2ARUB100LT2
ARUB440LT2ARUB160LT2ARUB140LT2ARUB140LT2
ARUB460LT2ARUB160LT2ARUB160LT2ARUB140LT2
ARUB480LT2ARUB160LT2ARUB160LT2ARUB160LT2
DC Inverter Scroll / Constant speed Scroll
Propeller Fan(DC INV)
Warm Gray
Gold finR410A
RatiooftheconnectableindoorunitsLongestpipinglength/Leveldifference**
50~130%
200m/100m
* Specifications22HP
Model Combinationunit Independentunit
Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling HeatingPowerSupply Ø,V,HzDimensions(WxHxD) mmWeight kgColorNoiselevel dBA±3Fan Type Airflowrate [CMM]Compressor Type NumberofcompressorsHeatExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping Liquid(flare) mm(inch)Connections SuctionGas mm(inch) DischargeGas mm(inch)NumberofoutdoorunitNumberofmaximumconnectableindoorunits*
26 34323028
61.6
69.3
17.13
16.33
3.60
4.24
3, 380~415, 50
(1280x1607x730)x2
240+285
61
380
3
8+8
5.6+3.3
Ø15.88(5/8)
Ø34.9(1 3/8)
Ø28.58(1 1/8)
2
35(44)
72.8
81.9
20.93
19.65
3.48
4.17
3, 380~415, 50
(1280x1607x730)x2
285+285
61
380
4
8+8
5.6+5.6
Ø19.05(3/4)
Ø34.9(1 3/8)
Ø28.58(1 1/8)
2
42(52)
78.4
88.2
23.70
21.20
3.31
4.16
3, 380~415, 50
(1280x1607x730)x2
285+285
61
380
4
8+8
EEV
FVC68D(PVE)
5.6+5.6
Ø19.05(3/4)
Ø34.9(1 3/8)
Ø28.58(1 1/8)
2
45(56)
84.0
94.5
25.85
23.00
3.25
4.11
3, 380~415, 50
(1280x1607x730)x2
285+285
61
380
4
8+8
5.6+5.6
Ø19.05(3/4)
Ø34.9(1 3/8)
Ø28.58(1 1/8)
2
49(60)
89.6
100.8
28.00
24.80
3.20
4.06
3, 380~415, 50
(1280x1607x730)x2
285+285
61
380
4
8+8
5.6+5.6
Ø19.05(3/4)
Ø34.9(1 3/8)
Ø28.58(1 1/8)
2
52(64)
95.2
107.1
26.21
25.38
3.63
4.22
3, 380~415, 50
(1280x1607x730)x3
240+285+285
63
570
5
8+8+8
5.6+5.6+3.3
Ø19.05(3/4)
Ø34.9(1 3/8)
Ø28.58(1 1/8)
3
55
67.2
75.6
19.28
18.13
3.49
4.17
3, 380~415, 50
(1280x1607x730)x2
240+285
61
380
3
8+8
5.6+3.3
Ø15.88(5/8)
Ø34.9(1 3/8)
Ø28.58(1 1/8)
2
39(48)
24ARUB220LT2ARUB140LT2ARUB80LT2
ARUB240LT2ARUB160LT2ARUB80LT2
ARUB260LT2ARUB140LT2ARUB120LT2
ARUB280LT2ARUB140LT2ARUB140LT2
ARUB300LT2ARUB160LT2ARUB140LT2
ARUB320LT2ARUB160LT2ARUB160LT2
ARUB340LT2ARUB140LT2ARUB120LT2ARUB80LT2
DC Inverter Scroll / Constant speed Scroll
Propeller Fan(DC INV)
Warm Gray
Gold finR410A
RatiooftheconnectableindoorunitsLongestpipinglength/Leveldifference**
50~160%
200m/100m
50~130%
* Specifications8HP
Model Combinationunit Independentunit
Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling HeatingPowerSupply Ø,V,HzDimensions(WxHxD) mmWeight kgColorNoiselevel dBA±3Fan Type Airflowrate [CMM]Compressor Type NumberofcompressorsHeatExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping Liquid(flare) mm(inch)Connections SuctionGas mm(inch) DischargeGas mm(inch)NumberofoutdoorunitNumberofmaximumconnectableindoorunits*
10 2018161412ARUB80LT2ARUB80LT2
ARUB100LT2ARUB100LT2
ARUB120LT2ARUB120LT2
ARUB140LT2ARUB140LT2
ARUB160LT2ARUB160LT2
ARUB180LT2ARUB100LT2ARUB80LT2
ARUB200LT2ARUB120LT2ARUB80LT2
22.4
25.2
5.28
5.73
4.24
4.40
3, 380~415, 50
1280x1607x730
240
58
190
1
8
3.3
Ø9.52(3/8)
Ø19.05(3/4)
Ø15.88(5/8)
1
13(20)
28.0
31.5
7.16
7.33
3.91
4.30
3, 380~415, 50
1280x1607x730
285
58
190
2
8
5.6
Ø9.52(3/8)
Ø22.2(7/8)
Ø19.05(3/4)
1
16(25)
33.6
37.8
9.08
9.05
3.70
4.18
3, 380~415, 50
1280x1607x730
285
58
190
2
8
5.6
Ø12.7(1/2)
Ø28.58(1 1/8)
Ø19.05(3/4)
1
19(30)
39.2
44.1
11.85
10.60
3.31
4.16
3, 380~415, 50
1280x1607x730
285
58
190
2
8
EEV
FVC68D(PVE)
5.6
Ø12.7(1/2)
Ø28.58(1 1/8)
Ø22.2(7/8)
1
23(35)
44.8
50.4
14.00
12.40
3.20
4.06
3, 380~415, 50
1280x1607x730
285
58
190
2
8
5.6
Ø12.7(1/2)
Ø28.58(1 1/8)
Ø22.2(7/8)
1
26(40)
50.4
56.7
12.44
13.06
4.05
4.34
3, 380~415, 50
(1280x1607x730)x2
240+285
61
380
3
8+8
5.6+3.3
Ø15.88(5/8)
Ø28.58(1 1/8)
Ø22.2(7/8)
2
29(36)
56.0
63.0
14.36
14.78
3.90
4.26
3, 380~415, 50
(1280x1607x730)x2
240+285
61
380
3
8+8
5.6+3.3
Ø15.88(5/8)
Ø28.58(1 1/8)
Ø22.2(7/8)
2
32(40)
Propeller Fan(DC INV)
Warm Gray
Gold finR410A
RatiooftheconnectableindoorunitsLongestpipinglength/Leveldifference**
50~200%
200m/100m
50~160%
DC Inverter Scroll DC Inverter Scroll / Constant speed Scroll
Note:
1.Capacitiesarebasedonthefollowingconditions Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB
Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5m Interconnecting piping length 7.5mLevel difference of zero Level difference of zero
2.Capacitiesarenetcapacities3.Duetoourpolicyofinnovationsomespecificationsmaybechangedwithoutnotification4.EEV:ElectronicExpansionValve
**ConditionalApplicationTomake40~90mofpipelengthafterfirstbranchrefertothepartof“installationofoutdoorunits”inPDB
• A combination operation over 100% cause to reduce each indoor unit capacity
• Combinationratio(50~200%)No. of outdoor unit Connection CapacitySingle unit 200%Double unit 160%Triple unit 130%
CAUTION We can guarantee the operation only within 130% Combination.If you want to connect more than 130% combination, please contact us and discuss the requirement like below.
1) If the operation of indoor unit is more than 130%, low airflow operation is recommended in all the indoor units. 2) If the operation of indoor unit is more than 130%, additional refrigerant is needed according to the headquarter guidance. 3) Over 130%, capacity is same as capacity of 130%, Same remark is valid for power input.
*Thenumberof()meansthenumberofmax.connectableindoorunits,whentheconnectedcapacityofindoorunitsisinthetable below.
LG A
ir Conditioners System
34_
35O
utdoor Unit_
MU
LTI V SPACE II
COMFORT & SILENCETheconceptofthebalconyischangedwiththeoutdoorunitthatdoesnotgeneratehotair.LownoiseandvibrationtechnologyofMULTIVSPACEIIensuresaquietenvironment.
•MULTIVSPACEII FrontSuction&FrontDischarge•Rightandleftsideairflowsystem
•Highspeedairdischarging(7~8m/sec)
•Nointerferencebetweeneachfloors(Efficiencyreductionduetohotairbackflow)
HotairBuildingwind
Right outoor unit
Left outoor unit
7m/s7m/s
•MULTIVSPACEII •Conventional QuietOperationThenoiseandvibrationarereducedby-Frontdischarge-Sealedstructureofoutdoorunit
Theindoornoiselevelismaintainedat30~40dBA,asquietasbeinginthelibrary
•Conventional Interference between floors!
No efficiency reduction!
•LGpatents:57items LGPatentForMULTIVSPACEIIAlltechnologiesintheMULTIVSPACEIIwhichmakeitadistinctive,uniqueunithavebeenappliedforpatentsdomesticallyandinternationally.and,someofthemhavealreadybeenregistered.
01 Whole structure (8 items)Air handler structrue (18 items)Separation of suction & discharge (6 items)3-side heat exchange structure (3 items)Louver structure /control (20 items)Electrical part(2 items)
02
03
04
05
06
06
05
04
03
02
01
EconomicandaestheticspacedesignMULTIV
SPACEIIisidealforrefinedandluxuriousliving
spaces.
Enjoyaclean&comfortablelifewithMULTIV.
*6HP (ARUN60LR2, ARUN60LL2)*8HP (ARUN80LR2, ARUN80LL2)
LG A
ir Conditioners System
36_
37O
utdoor Unit_
MU
LTI V SPACE II
• DC Inverter Compressor & Fan Motor
• Blackbox Function
• Night Silent Operation
• Pump Down
‘09 New Feature
Note :
1. Capacities are based on the following conditions Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB
Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5m Interconnecting piping length 7.5mLevel difference of zero Level difference of zero
2. Capacities are net capacities3. Due to our policy of innovation some specifications may be changed without notification4. EEV : Electronic Expansion Valve
1stepsLouver frame
4stepsFan parts
3stepsMechanical parts
2stepsSystem louver
4-Step Modularized Design• Modularized design of the outdoor unit provides simpler installation and maintenance.
• Outdoor unit can be installed according to overall building construction schedule.
• Louver is provided locally
Discharging
Duct
Duct application Fan RPM Control (E.S.P & Noise Control)
• Enhanced installation flexibility (Duct application)
• No need of high static pressure exhaust fan and air guide
• Keeping capacity and noise level as desired
How to set up
Step 1 >4mmAq < ESP < 6mmAq
Step 2 >6mmAq < ESP < 8mmAq
Step 3 >8mmAq < ESP < 10mmAq
Step 4 >10mmAq < ESP < 12mmAq
1 2 3 4 5 6 7 8 9 10 11 12 13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
- E.S.P control
- Noise control1 2 3 4 5 6 7 8 9 10 11 12 13 14 Low blowing noise
> Max - 100 rpm
Economic and aesthetic space design MULTI V
SPACE II is ideal for refined and luxurious living
spaces.
HPModel Independent unit Capacity Cooling kW Heating kWPower Cooling kWInput Heating kWCOP Cooling kW Heating kWPower Supply Ø, V, HzDimensions(WxHxD) mmWeight kgColorNoise level dBA±3E.S.P range mmAqFan Type Air flow rate [CMM]Compressor Type Number of compressorsHeat ExchangerRefrigerant Type Charge kg ControlRefrigerant TypeOil Charge lPiping Liquid(flare) mm(inch)Connections Gas(Bazing) mm(inch)Number of outdoor unitNumber of maximum connectable indoor unitsRatio of the connectable indoor unitsLongest piping length / Level difference
16.0
18.0
4.7
4.9
3.40
3.67
3, 380~415, 50
750 x 1790 x 650
200
49
4~12
100
1
5.2
2.3
9.52(3/8)
19.05(3/4)
1
9
* Specifications
6
21.7
23.0
6.7
6.7
3.24
3.43
3, 380~415, 50
750 x 1790 x 650
200
53
4~12
100
1
5.2
2.3
9.52(3/8)
19.05(3/4)
1
13
8ARUN60LR2 (Right Discharge)
ARUN60LL2 (Left Discharge)
ARUN80LR2 (Right Discharge)
ARUN80LL2 (Left Discharge)
Warm Gray
Sirocco Fan
DC INV Scroll
Gold Fin
R410A
EEV
FVC68D(PVE)
50~130%
150m/50m
* Preliminary data (8HP model)
LG A
ir Conditioners System
38_
39Indoor U
nit
Wall mounted
ARTCOOL
Ceiling Cassette
Ceiling Concealed Duct
Ceiling & Floor
Ceiling Suspended
Floor standing
49505256606162
M U LT I V i n d o o r
If you need a highly efficient air conditioning system in your building, MULTI V is the right choice for you.
Indoor unit
Wall Mounted
Mirror
4Way Casstte
2Way Casstte
1Way Casstte
Low Static
Built-in
High Static
Ceiling & Floor
Ceiling Suspended
Floor Standing- With Case
Floor Standing- Without Case
LG A
ir Conditioners System
40
_4
1Indoor U
nit
Aesthetic DesignYou no longer have to be told what your air conditioner should look like. With LG’s revolutionary ARTCOOL photo changeable, you can simply change the look of your air conditioner to what you want, when you want to.
ARTCOOL series with outstanding designs have received International Forum Design Award,
Reddot Design Award and G Mark.
Silver 07/09/12GSFV2 Gold 07/09/12GSFG2 Red 07/09/12GSFE2
Low NoiseSuper light BLDC motor guarantees your enhanced comfortable indoor environment.
Typing Office Conversation Library 4 way CST
- How to change the picture
- Panel type
- ARTCOOL Mirror
Auto Elevation GrilleEasy filter cleaning with elevation grille
- Installed inside main body- Auto horizontal level- 4 points support- Memory for user’s level- Max. 4.5m length
4 Way4.5m
Conventional3.5m
4-Point support structure Auto horizontal control
STOP
Memory
Memory for user’s level Auto bottom detection
Max
. 4.5
mSilver 07/09/12/15GSEV2 18/24GS8V2
Mirror 07/09/12/15GSER2 18/24GS8R2
Blue 07/09/12/15GSEB2 18/24GS8B2
• Aesthetic Design
• Low Noise
• 4 Vane Independent Operation
• Auto Elevation Grille
LG has been able to create a design conscious indoor unit that compliments any interior decoration. And they have improved air flow innovatively to realize world’s lowest noise, and provide a more pleasant and convenient indoor environment.
White silver 07/09/12GSFH2
4 Vanes Independent OperationVane angle control satisfies both users who like direct wind and indirect wind. and also it prevents cold air draft.
1 Vane, 1 Motor
1 : 20 °
0 : 30 °
2 : 40 °
3 : 50 ° 4 : 60 °5 : 70 °
All vane operation Individual vane operation
Air flow rate control Individual vane angel control
• Easy vane angle control with a remote controller
Direct air flow Indirect air flow
*Available for 24k ~ 48k Btu/h
LG A
ir Conditioners System
42_
43
Indoor Unit
High Ceiling ModeHigh ceiling mode with phase-control algorithm is possible to apply as high as 3.6m of ceiling.
4 way CSTConventional
Wide Jet VaneImproved wide and narrow vane will provide comfortable temperature distribution withoutair flow dead zone.
80mm Wider!! 567mm
487mm
NEW
Current
Even air distributiont262524232221201918
27°CTemp.
15°C
Highlander
Air flow dead zonet262524232221201918
27°CTemp.
15°C
Current
• Air flow improvement
Flexible ConnectionFlexible connection of remote controller
- Group control : 1 remote controller to several indoor units
- Second remote control : 2 remote controllers to 1 indoor unit
Easy & solid attachment to the wall wall
wall
Application of Ceiling Concealed DuctIt is possible to make each rooms cool & warm with installing a chamber and a spiral duct.
Max. 9 discharging
Linear E.S.P ControlAir volume and sound are always kept as design regardless of E.S.P changeusing this technology , you can
• Optimize duct work Installation• Keep capacity & sound level as desired• Simplify model numbers
The phase control motor technology offers money saving benefit to the installer.
*E.S.P is easily controlled by remote controller
Application of Built-in DuctBuilt-in duct has no need of duct space with using suction canvas and grille.
CanvasGrille
• Wide Jet Vane
• High Ceiling Mode
• Flexible Connection
• Appliaction of Ceiling Concealed Duct
• Appliaction of Built-in Duct
• Linear E.S.P Control
LG has been able to create a design conscious indoor unit that compliments any interior decoration. And they have improved air flow innovatively to realize world’s lowest noise, and provide a more pleasant and convenient indoor environment.
* For 4 way cassette (570 * 570), this function will be applied from May.
LG A
ir Conditioners System
44
_4
5Indoor U
nit
Drain hose Drain pump
One Touch Type PanelIt provides easy installation with a one-touch detachable panel.
Compact SizeThe indoor unit with slim and compact size has reduced the restriction which enables successful installation in various spaces.
LG conventional
204mm
218mm
246mm
288mm
6.0 ~ 7.2 kW 8.3 ~ 11.0 kW
Back
Side Floor
Sliding Type FilterEasy maintenance and extended product life with sliding type anti-biotic filter.
Sliding type
Anti-biotic filter Easy cleaning
Convenient InstallationEasy installation with corner detachable decoration panel.
• Coner detachable design
Drain leakage check
Refrigerantpiping check
Hanger adjust Hanger adjust
• Compact Size
• One Touch Type Panel
• Convenient Installation
• Easy Drain Installation
• 3Way Flexible Installation
• Sliding Type Filter
LG has been able to create a design conscious indoor unit that compliments any interior decoration. And they have improved air flow innovatively to realize world’s lowest noise, and provide a more pleasant and convenient indoor environment.
Drain leakage check Hanger adjust
Easy Drain InstallationIt reduces the installation time by over 40% with elbow-less drain hose.
Midget drain pump covers maximum 800mm high, featuring easy piping installation.
3Way Flexible InstallationAll sides (front, back, floor) are possibleto install and connect to the outdoor unit.
* Accessory (Drain hose) PHDHA05T – 500mm 30EA PHDHA07T - 700mm 30EA PHDHA05B – 500mm 5EA PHDHA07B – 700mm 5EA
LG A
ir Conditioners System
46
_4
7Indoor U
nit
Digital Air Flow ControlThe air flow can be controlled to ensure maximum comfort and convenience.
Normal fast & even widely
Jet cool speedy & powerful
Sleep mode indirectly & softly
Neo Plasma Air Purifying SystemLG’s unique NEO Plasma air purifying system is equipped with 7 specialized filters in 5 separate stages to enhance its cleaning power. It reduces fine dust and mold, unpleasant odors and cigarette smoke as air passes through each filter.
Swirl swing (plaesant air) Normal air flow
Vertical Temp. differences Horizontal Temp. differences
• Comparison of temperatures
Swirl SwingSwirl swing distributes air evenly throughout the room to ensure a more comfortable conditioned environment by adjusting the movement of the vane.
Nano Bio Fusion Filter
Nano bio fusion filters allow their nanosize bio enzymes to directly penetrate through cell walls of some bacteria and allergen to decompose its cell nuclei.
* Test Result Certification
Distinctions from Conventional Filters
The bio enzyme destroys cell walls and nuclei of some bacteria and allergens.
• Nano Bio Fusion Filter
• Conventional
Simply inactivatebacteria
Destroy bacteria but allowpart of them to survive
Pre Filter
The antibacterial pre-filter primarily reduces large dust, mold and quilt dust.
01
Nano Carbon Filter
Nano-size carbon filters remove fine odorous particles from the household air resulting in a more pleasant environment.
What is Nano Carbon Ball?Microscopic sized (1/1000000000) filter to ensure optimal filtration of odors.
200~500nm
02
Triple Filter
The triple filter consists of three specialized filters to reduce the symptoms associated with various organic compounds including formaldehyde. It also has the ability to reduce unpleasant odors creating a more comfortable environment.
03
04
Plasma Filter
The PLASMA Air Purifying System developed uniquely by LG not only reduces microscopic contaminants and dust, but also reduces house mites, pollen, and pet fur to reduce allergy and asthma symptoms.
05
Bio Active Site
NanoParticle
Active State Bacteria Selective Capture
Bacteriolysis Regeneration(Active State)
NanoParticle
NanoParticle
NanoParticle
Bacteria, Virus
Clean AirPolluted Air
01 02 03 04 05
Odor Free! Dust Free! Allergy Free!
LG has been able to create a design conscious indoor unit that compliments any interior decoration. And they have improved air flow innovatively to realize world’s lowest noise, and provide a more pleasant and convenient indoor environment.
• Neo Plasma Air Purifying System
• Digital Air Flow Control
• Swirl Swing
• Child Lock Function
Healthy DehumidificationDehumidification mode reducesuncomfortable humidity from theroom without over cooling.
LG Healthy DehumidificationBy increasing the vane angle, a better approach of the actual temperature is possible to prevent over cooling.
ConventionalSince the surrounding temperature is measured after the air from the unit is widely distributed, accurate approach of the air is not possible.
Indoor Temperature Distribution Chart
LG A
ir Conditioners System
48
_4
9Indoor U
nit
Weekly ProgramThe operator can set an on/off reservation of the air conditioner for a period of one week.
LCD Wired Remote Controller• On/Off• Test run mode• Self-diagnosis• 3-step fan speed selection• Operation indication• Room temperature
Auto CleanAuto clean helps to remove odor and save clean-up time. After using airconditioner, “Auto clean” makes the inner part of Air conditioner dry for 30 min. It removes mositure and mold so you can enjoy odor-free air and save time to clean up.
LG Auto Clean Conventional
Dries the evaporator with gentle low noise air from the fan by removing any remaining moisture.Pressing the Auto Clean button will activate the automatic cleaning function after the cooling operation.
1 STEP
Removes moulds through the neo plasma system.Only the fan will operate to dry the inner part of the air conditioner in just 30 minutes.
2 STEP
Air Flow Direction ControlHorizontal airflow control- Adjust the horizontal airflow direction by manually moving the horizontal airflow direction vane by hand.
Vertical airflow- The airflow direction can be adjusted as desired by using the remote controller.
Horizontal airflow control Vertical airflow control
ARNU07GSEL2 / ARNU09GSEL2ARNU12GSEL2 / ARNU15GSEL2ARNU18GS5L2 / ARNU24GS5L2
Wall Mounted
LG has been able to create a design conscious indoor unit that compliments any interior decoration. And they have improved air flow innovatively to realize world’s lowest noise, and provide a more pleasant and convenient indoor environment.
Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions(WxDxH) mmWeight kgNoise level dBA±3Air flow rate H/M/L CMMNeo Plasma air purifying filterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm
Model Unit ARNU07GSEL2 ARNU12GSEL2 ARNU24GS5L2ARNU09GSEL2 ARNU18GS5L2
1, 220~240, 50
ARNU15GSEL2
* Specifications
2.27,500
2.58,500
4040
937 / 33 / 235.6 / 5 / 4.6
oØ6.35(1/4)Ø12.7(1/2)
20/16
3.612,300
4.013,600
4040
941 / 36 / 279.5 / 9 / 8.5
oØ6.35(1/4)Ø12.7(1/2)
20/16
7.124,200
8.027,300
4040
1246 / 41 / 3814 / 13 / 10
oØ9.52(3/8)
Ø15.88(5/8)20/16
2.89,600
3.210,900
4040
939 / 35 / 257 / 6.5 / 6
oØ6.35(1/4)Ø12.7(1/2)
20/16
5.619,100
6.321,500
4040
1244 / 40 / 3612 / 10.5 / 9
oØ6.35(1/4)Ø12.7(1/2)
20/16
4.515,400
5.017,100
4040
942 / 36 / 27
10.5 / 9 / 8.5o
Ø6.35(1/4)Ø12.7(1/2)
20/16
895x165x282 1090x178x300
* AccessoriesModel
Dry ContactPQDSA
PQDSB/ PQDSB1PQDSBC
Without case(1 contact point)
With case(1 contact point)
With case(2 contact point)
ARNU07GSEL2 ARNU12GSEL2 ARNU24GS5L2ARNU09GSEL2 ARNU18GS5L2ARNU15GSEL2
Wired remote controller Wireless remote controller
Deluxe type
PQRCUDS0*Standard type
PQRCUSA1 Simple type
PQRCUCS0C Simple type for hotel
PQRCFCS0C PQWRHDF0
SUNDAY
MONDAY
TUESDAY
WEDNESDAY
THURSDAY
FRIDAY
SATURDAY
Note :
1. Capacities are based on the following conditions Cooling-Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Heating-Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Interconnecting piping length 7.5m Level difference of zero Level difference of zero2. Due to our policy of innovation some specifications may be changed without notification
Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPowerSupply Ø,V,HzDimensions(WxDxH) mmWeight kgNoiselevel dBA±3Airflowrate H/M/L CMMNeoPlasmaairpurifyingfilterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm
LG A
ir Conditioners System
50_
51Indoor U
nit_ARTCO
OL G
allery / Mirror
ARNU07GSF*2 / ARNU09GSF*2ARNU12GSF*2
* SpecificationsModel Unit ARNU07GSF*2 ARNU09GSF*2 ARNU12GSF*2
2.27,500
2.58,500
3535
1538 / 32 / 27
8.1 / 6.3 / 4.2o
Ø6.35(1/4)Ø12.7(1/2)16.2/12.2
2.89,600
3.210,900
3535
1, 220~240, 50600x146x600
1538 / 32 / 27
8.1 / 6.3 / 4.2o
Ø6.35(1/4)Ø12.7(1/2)16.2/12.2
3.612,300
4.013,600
3535
1544 / 38 / 32
9.3 / 7.7 / 6.0o
Ø6.35(1/4)Ø12.7(1/2)16.2/12.2
* AccessoriesModel
DryContactPQDSA
PQDSB/PQDSB1PQDSBC
ARNU07GSF*2 ARNU09GSF*2 ARNU12GSF*2
Withoutcase(1contactpoint)Withcase(1contactpoint)Withcase(2contactpoint)
Silver Gold
Red WhiteSilver
*1:Photochangeable,V:Silver,E:Red,G:Gold,H:WhiteSilver
*Photochangeable
Wiredremotecontroller Wirelessremotecontroller
Deluxetype
PQRCUDS0*Standardtype
PQRCUSA1Simpletype
PQRCUCS0CSimpletypeforhotel
PQRCFCS0C PQWRHDF0
*Checkupthenote,refertoonthe49page.
*Paneltype
MirrorARNU07GSE*2 / ARNU09GSE*2 / ARNU12GSE*2 ARNU15GSE*2 / ARNU18GS8*2 / ARNU24GS8*2
Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPowerSupply Ø,V,HzDimensions(WxDxH) mmWeight kgNoiselevel dBA±3Airflowrate H/M/L CMMNeoPlasmaairpurifyingfilterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm
Model Unit ARNU07GSE*2
* Specifications
1170x173x315
ARNU09GSE*2 ARNU12GSE*2 ARNU18GS8*2 ARNU24GS8*2
1, 220~240, 50
ARNU15GSE*2
* AccessoriesModel
DryContactPQDSA
PQDSB/PQDSB1PQDSBC
Withoutcase(1contactpoint)Withcase(1contactpoint)Withcase(2contactpoint)
ARNU07GSE*2 ARNU09GSE*2 ARNU12GSE*2 ARNU15GSE*2 ARNU24GS8*2ARNU18GS8*2
2.27,500
2.58,500
4040
11.237 / 33 / 23
7 / 6 / 4 o
Ø6.35(1/4)Ø12.7(1/2)
20/16
2.89,600
3.210,900
4040
11.239 / 35 / 25
8 / 7 / 5 o
Ø6.35(1/4)Ø12.7(1/2)
20/16
3.612,300
4.013,600
4040
11.241 / 36 / 27
10 / 8 / 6 o
Ø6.35(1/4)Ø12.7(1/2)
20/16
5.619,100
6.321,500
4040
1337 / 34 / 31
14.4 / 13 / 11 o
Ø6.35(1/4)Ø12.7(1/2)
20/16
7.124,200
8.027,300
4040
1343 / 37 / 32
17.9 / 14.4 / 12 o
Ø9.52(3/8)Ø15.88(5/8)
20/16
4.515,400
5.017,100
4040
11.242 / 36 / 2710.5 / 8 / 6
oØ6.35(1/4)Ø12.7(1/2)
20/16
915x169x282
Wiredremotecontroller Wirelessremotecontroller
Deluxetype
PQRCUDS0*Standardtype
PQRCUSA1Simpletype
PQRCUCS0CSimpletypeforhotel
PQRCFCS0C PQWRHDF0
Silver
Mirror
Blue
*R:Mirror,B:Blue,V:Silver
*Checkupthenote,refertoonthe49page.*Preliminarydata(18~24kmodel)
LG A
ir Conditioners System
52_53
Indoor Unit_
Ceiling Cassette
ARNU05GTRC2 / ARNU07GTRC2ARNU09GTRC2 / ARNU12GTRC2ARNU15GTQC2 / ARNU18GTQC2
ARNU24GTPC2 / ARNU28GTPC2ARNU36GTNC2 / ARNU42GTMC2 ARNU48GTMC2
4 Way Cassette (570*570) 4 Way Cassette (840*840)
Wired remote controller Wireless remote controller
Deluxe type
PQRCUDS0*Standard type
PQRCUSA1 Simple type
PQRCUCS0C Simple type for hotel
PQRCFCS0C PQWRHDF0
Wired remote controller Wireless remote controller
Deluxe type
PQRCUDS0*Standard type
PQRCUSA1 Simple type
PQRCUCS0C Simple type for hotel
PQRCFCS0C PQWRHDF0
Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions Body mm(WxDxH) Front panel mmWeight Body kg Front panel Panel ColorNoise level dBA±3Air flow rate H/M/L CMMNeo Plasma air purifying filterDrain PumpPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm
* SpecificationsModel Unit
5.619,100
6.321,500
4545
15.52.5
38 / 37 / 3611.2 / 11 / 10
oo
Ø6.35(1/4)Ø12.7(1/2)
32/25
2.27,500
2.58,500
4545
13.12.3
36 / 35 / 337.5 / 7 / 6.6
oo
Ø6.35(1/4)Ø12.7(1/2)
32/25
2.89,600
3.210,900
4545
14.22.3
36 / 35 / 348 / 7.5 / 7.1
o o
Ø6.35(1/4)Ø12.7(1/2)
32/25
3.612,300
4.013,600
4545
14.22.3
36 / 35 / 348.7 / 8 / 7
oo
Ø6.35(1/4)Ø12.7(1/2)
32/25
4.515,400
5.017,100
4545
15.52.5
37 / 36 / 3511 / 10 / 9.3
oo
Ø6.35(1/4)Ø12.7(1/2)
32/25
1, 220 ~ 240, 50570 x 570 x 214
700x700x30
Morning Fog
* Check up the note, refer to on the 49 page.
1.65,500
1.86,100
4545
13.12.3
36 / 35 / 337.5 / 7 / 6.6
oo
Ø6.35(1/4)Ø12.7(1/2)
32/25
ARNU07GTRC2 ARNU09GTRC2 ARNU12GTRC2 ARNU18GTQC2ARNU15GTQC2ARNU05GTRC2
570 x 570 x 256
* AccessoriesModel
Dry ContactPQDSA
PQDSB/ PQDSB1
PQDSBC
PT-UQC
Without case(1 contact point)
With case(1 contact point)
With case(2 contact point)
Front Panel
ARNU07GTRC2 ARNU09GTRC2 ARNU12GTRC2 ARNU18GTQC2ARNU15GTQC2ARNU05GTRC2
Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions Body mm(WxDxH) Front Panel mmWeight Body kg Front Panel kgPanel ColorNoise level dBA±3Air flow rate H/M/L CMMNeo Plasma air purifying filterDrain PumpPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm
* SpecificationsARNU28GTPC2 ARNU36GTNC2 ARNU42GTMC2 ARNU48GTMC2
8.228,000
9.231,500
3333
20.84.5
39 / 38 / 3219 / 16 / 14
oo
Ø9.52(3/8)Ø15.88(5/8)
32/25
10.636,200
11.940,600
144144
23.54.5
43 / 40 / 3925 / 21 / 19
oo
Ø9.52(3/8)Ø15.88(5/8)
32/25
12.342,000
13.843,800
144144
25.64.5
47 / 44 / 4230 / 27 / 24
oo
Ø9.52(3/8)Ø15.88(5/8)
32/25
14.148,100
15.951,200
144144
25.64.5
48 / 47 / 4531 / 29 / 27
oo
Ø9.52(3/8)Ø15.88(5/8)
32/25
Model Unit7.1
24,2008.0
27,3003333
20.84.5
38 / 35 / 3117 / 15 / 13
oo
Ø9.52(3/8)Ø15.88(5/8)
32/25
950x950x25
ARNU24GTPC2
840x840x204 840x840x2881, 220 ~ 240, 50
840x840x246
Morning Fog
* Check up the note, refer to on the 49 page.
* AccessoriesModel
Dry ContactPQDSA
PQDSB/ PQDSB1PQDSBCPT-UMCPTEGM0
PTVK410 / PTVK420 / PTVK 430
Without case(1 contact point)
With case(1 contact point)
With case(2 contact point)
ARNU28GTPC2 ARNU36GTNC2 ARNU42GTMC2 ARNU48GTMC2ARNU24GTPC2
Front PanelAuto Elevation GrilleVentilation Kit
Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions Body mm(WxDxH) Front Panel mmWeight Body kg Front Panel kgPanel ColorNoise level dBA±3Air flow rate H/M/L CMMNeo Plasma air purifying filterDrain PumpPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm
LG A
ir Conditioners System
54_
55Indoor U
nit_Ceiling Cassette
ARNU18GTLC2 / ARNU24GTLC2 ARNU07GTJC2 / ARNU09GTJC2ARNU12GTJC2
* Specifications
7.124,200
8.027,300
7070
224
42 / 37 / 3217 / 15 / 13
oo
Ø9.52(3/8)Ø15.88(5/8)
32/25
Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions Body mm(WxDxH) Front Panel mmWeight Body kg Front Panel kgPanel ColorNoise level dBA±3Air flow rate H/M/L CMMNeo Plasma air purifying filterDrain PumpPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm
Model Unit5.6
19,1006.3
21,5007070
224
40 / 35 / 3013 / 12 / 10
oo
Ø6.35(1/4)Ø12.7(1/2)
32/25
ARNU18GTLC2 ARNU24GTLC2
1, 220 ~ 240, 50830x550x225
1050x640x28.5
* SpecificationsModel Unit
3.612,300
4.013,600
4040
11.51.5
41 / 39 / 378 / 7 / 6
o o
Ø6.35(1/4)Ø12.7(1/2)
32/25
2.27,500
2.58,500
4040
11.51.5
40 / 38 / 377.5 / 6.5 / 6
oo
Ø6.35(1/4)Ø12.7(1/2)
32/25
2.89,600
3.210,900
4040
11.51.5
40 / 38 / 377.5 / 6.5 / 6
oo
Ø6.35(1/4)Ø12.7(1/2)
32/25
ARNU07GTJC2 ARNU09GTJC2 ARNU12GTJC2
1, 220 ~ 240, 50860x410x1381070x480x20
Morning Fog
2 Way Cassette 1 Way Cassette
* AccessoriesModel
Dry ContactPQDSA
PQDSB/ PQDSB1
PQDSBC
PT-HLC
Without case(1 contact point)
With case(1 contact point)
With case(2 contact point)
ARNU18GTLC2 ARNU24GTLC2
Front panel
* AccessoriesModel
Dry ContactPQDSA
PQDSB/ PQDSB1
PQDSBC
PT-HJC
Without case(1 contact point)
With case(1 contact point)
With case(2 contact point)
Front panel
ARNU07GTJC2 ARNU09GTJC2 ARNU12GTJC2
Morning Fog
Wired remote controller Wireless remote controller
Deluxe type
PQRCUDS0*Standard type
PQRCUSA1 Simple type
PQRCUCS0C Simple type for hotel
PQRCFCS0C PQWRHDF0
Wired remote controller Wireless remote controller
Deluxe type
PQRCUDS0*Standard type
PQRCUSA1 Simple type
PQRCUCS0C Simple type for hotel
PQRCFCS0C PQWRHDF0
* Check up the note, refer to on the 49 page. * Check up the note, refer to on the 49 page.
Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPowerSupply Ø,V,HzDimensions(WxDxH) mmSuctiongrille(WxDxH)Suctioncanvas(WxHxD)Weight kgNoiselevel dBA±3E.S.Prange mmAqAirflowrate H/M/L CMMNeoPlasmaairpurifyingfilterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm
LG A
ir Conditioners System
56_
57Indoor U
nit_Ceiling Concealed D
uct
ARNU07GB1G2 / ARNU09GB1G2ARNU12GB1G2 / ARNU15GB1G2ARNU18GB2G2 / ARNU24GB2G2
ARNU07GB3G2 / ARNU09GB3G2ARNU12GB3G2 / ARNU15GB3G2ARNU18GB4G2 / ARNU24GB4G2
* Specifications
Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPowerSupply Ø,V,HzDimensions(WxDxH) mmWeight kgNoiselevel dBA±3E.S.PrangemmAqAirflowrate H/M/L CMMNeoPlasmaairpurifyingfilterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm
Model Unit ARNU07GB1G2 ARNU09GB1G2 ARNU12GB1G2 ARNU18GB2G2 ARNU24GB2G2ARNU15GB1G2
* SpecificationsModel Unit ARNU07GB3G2 ARNU09GB3G2 ARNU12GB3G2 ARNU18GB4G2 ARNU24GB4G2ARNU15GB3G2
Low Static Duct Built-in Duct
* AccessoriesModel
DryContactPQDSA
PQDSB/PQDSB1
PQDSBC
Withoutcase(1contactpoint)Withcase(1contactpoint)Withcase(2contactpoint)
ARNU07GB1G2 ARNU09GB1G2 ARNU12GB1G2 ARNU18GB2G2 ARNU24GB2G2ARNU15GB1G2
* AccessoriesModel
DryContactPQDSA
PQDSB/PQDSB1
PQDSBC
Withoutcase(1contactpoint)Withcase(1contactpoint)Withcase(2contactpoint)
ARNU07GB3G2 ARNU09GB3G2 ARNU12GB3G2 ARNU18GB4G2 ARNU24GB4G2ARNU15GB3G2
SuctionGrilleSuctionCanvas
PBSGB30PBSC30
PBSGB40PBSC40
2.27,500
2.58,500
3030
2135 / 33 / 31
8.5 / 7.5 / 6.5-
Ø6.35(1/4)Ø12.7(1/2)
32/25.4
2.89,600
3.210,900
3030
2136 / 35 / 33
9.5 / 8.5 / 7.5-
Ø6.35(1/4)Ø12.7(1/2)
32/25.4
3.612,300
4.013,600
3030
2137 / 36 / 35
10.5 / 9.5 / 8.5-
Ø6.35(1/4)Ø12.7(1/2)
32/25.4
5.619,100
6.321,500
8080
2640 / 37 / 34
16 / 14 / 12-
Ø6.35(1/4)Ø12.7(1/2)
32/25.4
7.124,200
8.027,300
8080
2643 / 40 / 37
19 / 17 / 15-
Ø9.52(3/8)Ø15.88(5/8)
32/25.4
4.515,400
5.017,100
3030
2138 / 37 / 36
11.5 / 10.5 / 9.5-
Ø6.35(1/4)Ø12.7(1/2)
32/25.4
1, 220 ~ 240, 50
0~4
1100x575x190820x575x190
2.27,500
2.58,500
3030
2137 / 34 / 33
8 / 6.5 / 5.5-
Ø6.35(1/4)Ø12.7(1/2)
32/25.4
2.89,600
3.210,900
3030
2139 / 35 / 34
9 / 7 / 6-
Ø6.35(1/4)Ø12.7(1/2)
32/25.4
3.612,300
4.013,600
3030
2140 / 37 / 34
10 / 8 / 6.5-
Ø6.35(1/4)Ø12.7(1/2)
32/25.4
5.619,100
6.321,500
8080
2643 / 40 / 37
14 / 12 / 10-
Ø6.35(1/4)Ø12.7(1/2)
32/25.4
7.124,200
8.027,300
8080
2646 / 43 / 37
17 / 15 / 10-
Ø9.52(3/8)Ø15.88(5/8)
32/25.4
4.515,400
5.017,100
3030
2141 / 40 / 37
11 / 10 / 8-
Ø6.35(1/4)Ø12.7(1/2)
32/25.4
820x575x1901, 220~ 240, 50
910x359x56821x274x(45~250) 1100x274x(45~250)
1188x359x561100x575x190
0~4
Wiredremotecontroller Wirelessremotecontroller
Deluxetype
PQRCUDS0*Standardtype
PQRCUSA1Simpletype
PQRCUCS0CSimpletypeforhotel
PQRCFCS0C PQWRHDF0
Wiredremotecontroller Wirelessremotecontroller
Deluxetype
PQRCUDS0*Standardtype
PQRCUSA1Simpletype
PQRCUCS0CSimpletypeforhotel
PQRCFCS0C PQWRHDF0
*Forusingwirelessremotecontroller,itneedstoinstallstandardwiredremotecontroller.(Duct,Floorstandingmodel.)*Forusingwirelessremotecontroller,itneedstoinstallstandardwiredremotecontroller.(Duct,Floorstandingmodel.)
*Checkupthenote,refertoonthe49page.
*Checkupthenote,refertoonthe49page.
LG A
ir Conditioners System
58_
59Indoor U
nit_Ceiling Concealed D
uct
ARNU07GBHA2 / ARNU09GBHA2ARNU12GBHA2 / ARNU15GBHA2ARNU18GBHA2 / ARNU24GBHA2
* Specifications
Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions(WxDxH) mmWeight kgNoise level dBA±3E.S.P range mmAqAir flow rate H/M/L CMMNeo Plasma air purifying filterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm
Model Unit ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2 ARNU18GBHA2 ARNU24GBHA2
ARNU28GBGA2 / ARNU36GBGA2ARNU42GBGA2 / ARNU48GBRA2URNU76GB8A2 / URNU96GB8A2
* Specifications
Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions(WxDxH) mmWeight kgNoise level dBA±3E.S.P range mmAqAir flow rate H/M/L CMMNeo Plasma air purifying filterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm
Model Unit ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2 ARNU48GBRA2 URNU76GB8A2 URNU96GB8A2
1, 220 ~240, 501182x450x298
High Static Duct High Static Duct
* AccessoriesModel
Dry ContactPQDSA
PQDSB/ PQDSB1
PQDSBC
Without case(1 contact point)
With case(1 contact point)
With case(2 contact point)
ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2 ARNU48GBRA2 URNU76GB8A2 URNU96GB8A2
* AccessoriesModel
Dry ContactPQDSA
PQDSB/ PQDSB1
PQDSBC
Without case(1 contact point)
With case(1 contact point)
With case(2 contact point)
ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2 ARNU18GBHA2 ARNU24GBHA2
5.619,100
6.321,500
150150
26.542.5 / 41 / 37
15.5 / 13.5 / 12.4-
Ø6.35(1/4)Ø12.7(1/2)
32/25
7.124,200
8.027,300
150150
26.545 / 43 / 41
18.3 / 16.9 / 15.5-
Ø9.52(3/8)Ø15.88(5/8)
32/25
2.27,500
2.58,500150150
2634 / 33 / 32
8.5 / 7.5 / 6-
Ø6.35(1/4)Ø12.7(1/2)
32/25
2.89,600
3.210,900
150150
2635 / 34 / 33
10 / 8.5 / 7.5-
Ø6.35(1/4)Ø12.7(1/2)
32/25
3.612,300
4.013,600
150150
2637 / 35 / 34
12 / 10 / 8.5-
Ø6.35(1/4)Ø12.7(1/2)
32/25
4.515,400
5.017,100
150150
2639 / 38 / 37
13.5 / 12 / 8.5-
Ø6.35(1/4)Ø12.7(1/2)
32/25
8.228,000
9.231,500
450450
3844 / 42 / 40
6~1625.9 / 24.1 / 21.8
-Ø9.52(3/8)
Ø15.88(5/8)32/25
12.342,000
13.843,800
450450
3848 / 46 / 45
6~1234.5 / 32.3 / 30.7
-Ø9.52(3/8)
Ø15.88(5/8)32/25
14.148,100
15.951,200
450450
5345 / 43 / 41
7~2044.8 / 40.6 / 33.3
-Ø9.52(3/8)
Ø15.88(5/8)32/25
10.636,200
11.940,600
450450
3846 / 44 / 42
6~1432.3 / 29 / 25.3
-Ø9.52(3/8)
Ø15.88(5/8)32/25
22.476,400
25.286,000
800800
8750 / 48 / 48
64 / 50 / 50
-Ø9.52(3/8)
Ø19.05(3/4)32/25
28.095,900
31.5107,500
800800
8752 / 50 / 50
72 / 64 / 64
-Ø9.52(3/8)Ø22.2(7/8)
32/25
1, 220 ~240, 50882x450x260
4~12
1562x688x4601230x590x380
12-25
Wired remote controller Wireless remote controller
Deluxe type
PQRCUDS0*Standard type
PQRCUSA1 Simple type
PQRCUCS0C Simple type for hotel
PQRCFCS0C PQWRHDF0
Wired remote controller Wireless remote controller
Deluxe type
PQRCUDS0*Standard type
PQRCUSA1 Simple type
PQRCUCS0C Simple type for hotel
PQRCFCS0C PQWRHDF0
* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)
* Check up the note, refer to on the 49 page. * Check up the note, refer to on the 49 page.
LG A
ir Conditioners System
60
_6
1Indoor U
nit_Ceiling &
Floor / Ceiling Suspended
ARNU09GVEA2 / ARNU12GVEA2 ARNU18GVJA2 / ARNU24GVJA2
* Specifications
Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions(WxDxH) mmWeight kgNoise level dBA±3Air flow rate H/M/L CMMPlasma air purifying filterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm
Model Unit ARNU09GVEA2 ARNU12GVEA22.8
9,6003.2
10,9003030
13.7 36 / 32 / 28
7.6 / 6.9 / 6.2-
Ø6.35(1/4)Ø12.7(1/2)
20/16
3.612,300
4.013,600
3030
13.7 38 / 36 / 30
9.2 / 7.6 / 6.9-
Ø6.35(1/4)Ø12.7(1/2)
20/16
1, 220 ~ 240, 50900x200x490
* Specifications
Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions(WxDxH) mmWeight kgNoise level dBA±3Air flow rate H/M/L CMMNeo Plasma air purifying filterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(OD/ID) mm
Model Unit ARNU18GVJA2 ARNU24GVJA25.6
19,1006.3
21,5006363
24.642 / 40 / 3716 / 14 / 12
-Ø6.35(1/4)Ø12.7(1/2)
20/16
7.124,200
8.027,300
6363
24.643 / 41 / 3918 / 16 / 14
-Ø9.52(3/8)
Ø15.88(5/8)20/16
1, 220~240, 50950x220x650
Ceiling & Floor Ceiling Suspended
* AccessoriesModel
Dry ContactPQDSA
PQDSB/ PQDSB1
PQDSBC
Without case(1 contact point)
With case(1 contact point)
With case(2 contact point)
ARNU09GVEA2 ARNU12GVEA2
* AccessoriesModel
Dry ContactPQDSA
PQDSB/ PQDSB1
PQDSBC
Without case(1 contact point)
With case(1 contact point)
With case(2 contact point)
ARNU18GVJA2 ARNU24GVJA2
Wired remote controller Wireless remote controller
Deluxe type
PQRCUDS0*Standard type
PQRCUSA1 Simple type
PQRCUCS0C Simple type for hotel
PQRCFCS0C PQWRHDF0
Wired remote controller Wireless remote controller
Deluxe type
PQRCUDS0*Standard type
PQRCUSA1 Simple type
PQRCUCS0C Simple type for hotel
PQRCFCS0C PQWRHDF0
* Check up the note, refer to on the 49 page. * Check up the note, refer to on the 49 page.
LG A
ir Conditioners System
62_
63
Indoor Unit_
Floor Standing
ARNU07GCEA2 / ARNU09GCEA2ARNU12GCEA2 / ARNU15GCEA2ARNU18GCFA2 / ARNU24GCFA2
ARNU07GCEU2 / ARNU09GCEU2ARNU12GCEU2 / ARNU15GCEU2ARNU18GCFU2 / ARNU24GCFU2
Floor Standing with case
Floor Standing without case
* AccessoriesModel
Dry ContactPQDSA
PQDSB/ PQDSB1PQDSBC
Without case(1 contact point)
With case(1 contact point)
With case(2 contact point)
ARNU07GCEA2 ARNU18GCFA2ARNU09GCEA2 ARNU12GCEA2 ARNU24GCFA2ARNU15GCEA2
* AccessoriesModel
Dry ContactPQDSA
PQDSB/ PQDSB1
PQDSBC
Without case(1 contact point)
With case(1 contact point)
With case(2 contact point)
ARNU24GCFU2ARNU07GCEU2 ARNU18GCFU2ARNU09GCEU2 ARNU12GCEU2 ARNU15GCEU2
* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)* For using wireless remote controller, it needs to install standard wired remote controller. (Duct, Floor standing model.)
* Specifications
Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions(WxDxH) mmWeight kgNoise level dBA±3Air flow rate H/M/L CMMPlasma air purifying filterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(ID) mm
Model Unit ARNU07GCEA2 ARNU18GCFA2ARNU09GCEA2 ARNU12GCEA2 ARNU24GCFA2ARNU15GCEA2
* Specifications
Capacity Cooling kW Btu/h Heating kW Btu/hPower Cooling WInput Heating WPower Supply Ø, V, HzDimensions(WxDxH) mmWeight kgNoise level dBA±3Air flow rate H/M/L CMMPlasma air purifying filterPiping Liquid mm(inch)Connection Gas mm(inch) Drain(ID) mm
Model Unit ARNU07GCEU2 ARNU18GCFU2ARNU09GCEU2 ARNU12GCEU2 ARNU24GCFU2ARNU15GCEU22.2
7,5002.5
8,5003030
2735 / 33 / 31
8.5 / 7.5 / 6.5-
Ø6.35(1/4)Ø12.7(1/2)
12
5.619,100
6.321,500
8080
3440 / 37 / 3416 / 14 / 12
-Ø6.35(1/4)Ø12.7(1/2)
12
2.89,600
3.210,900
3030
2736 / 34 / 32
9.5 / 8.5 / 7.5-
Ø6.35(1/4)Ø12.7(1/2)
12
3.612,300
4.013,600
3030
2737 / 35 / 33
10.5 / 9.5 / 8.5-
Ø6.35(1/4)Ø12.7(1/2)
12
7.124,200
8.027,300
8080
3443 / 40 / 3718 / 16 / 14
-Ø9.52(3/8)
Ø15.88(5/8)12
4.515,400
5.017,100
30 30
2738 / 37 / 35
11.5 / 10 / 9.5-
Ø6.35(1/4)Ø12.7(1/2)
12
2.27,500
2.58,500
3030
2035 / 33 / 31
8.5 / 7.5 / 6.5-
Ø6.35(1/4)Ø12.7(1/2)
12
5.619,100
6.321,500
8080
2740 / 37 / 3416 / 14 / 12
-Ø6.35(1/4)Ø12.7(1/2)
12
2.89,600
3.210,900
3030
2036 / 34 / 32
9.5 / 8.5 / 7.5-
Ø6.35(1/4)Ø12.7(1/2)
12
3.612,300
4.013,600
3030
2037 / 35 / 33
10.5 / 9.5 / 8.5-
Ø6.35(1/4)Ø12.7(1/2)
12
7.124,200
8.027,300
8080
2743 / 40 / 3718 / 16 / 14
-Ø9.52(3/8)
Ø15.88(5/8)12
4.515,400
5.017,100
30 30
2038 / 37 / 35
11.5 / 10 / 9.5-
Ø6.35(1/4)Ø12.7(1/2)
12
1, 220~240, 501345x203x6351067x203x635
1, 220~240, 501256x190x639978x190x639
Wired remote controller Wireless remote controller
Deluxe type
PQRCUDS0*Standard type
PQRCUSA1 Simple type
PQRCUCS0C Simple type for hotel
PQRCFCS0C PQWRHDF0
Wired remote controller Wireless remote controller
Deluxe type
PQRCUDS0*Standard type
PQRCUSA1 Simple type
PQRCUCS0C Simple type for hotel
PQRCFCS0C PQWRHDF0
* Check up the note, refer to on the 49 page. * Check up the note, refer to on the 49 page.
LG A
ir Conditioners System
64
_6
5
Heat Recovery Ventilator
Features
Installation & Maintenance
Line-up
Specifications
62636466
eco V
With today’s concern for a healthy indoor environment, eco V is an integral component of HVAC system. eco V Using in the HVAC system allows contaminants to be removed quickly and effectively from the air-conditioned space.
Heat Recovery Ventilator
LG’s heat recovery ventilation system,
eco V, modulates the temperature and
humidity of incoming fresh air to match
indoor conditions. A balance is achieved
between indoor and outdoor ambient,
enabling the cooling or heating load
placed on the air conditioning system to
be reduced significantly.
(Heat Recovery ventilator)
(Heat Recovery ventilator)
LG A
ir Conditioners System
66
_6
7
Easy Cleaning and Changing FilterDoor attached side panel and slide removable Enthalpy heat exchanger filter can be changed without additional maintenance.
• Eco V unit
Top
Low
Low
Top
Reverse installationof 1 unit (Left unit)
Normal installationof 2 units
Flexibility of InstallationIt’s possible to install the opposite direction of upper and lower part. It needs the only one inspection hole.
• Inspection hole
Air Filter Air Filter
Strong Filter FunctionAir filterThe air filter has collection efficiency above 80%, which means it can filter particles up to 0.3 m including tobacco of smoke and even floating particles from yellow sand.
HEPA + Deodorization filter (accessory)The indoor air can be always kept fresh through these filters.
Yellow Sand filter (accessory)This filter can make more comfortable and fresh environment through removing harmful to health 5~20µm sandy dust over 99%.
• Air Filter
• HEPA+Deodorization Filter (accessory)
• Yellow Sand Filter (accessory)Dust collection efficiency (%) Pressure loss (Pa)
• Remove side panel
Installation & Maintenance • Flexibility Installation • Easy Cleaning and Changeable Filter
Features • High Efficiency Heat Exchanger • Bypass Ventilation • Strong Filter Function
High Efficiency Heat ExchangerEfficiency and comfort is ensured by the high-efficiency energy recovery central core which recovers energy from the indoor air and transfers it to the fresh incoming air without mixing airstream.
Exhaust air
Outdoor air (Option) Deodorization filter
Supply air
Indoor airHigh performance filter{
Bypass VentilationIt switches automatically the ventilation mode (Enthalpy Heat Exchange Mode / Bypass Mode) according to the indoor/outdoor temperature.
• Remove heat exchanger• Remove free filter
Damper Damper
• Enthalpy Heat Exchange Mode
• Bypass Mode
[Summer / Winter] [A change of season]
LG A
ir Conditioners System
68
_6
9 (H
eat Recovery ventilator)
The LG heat recovery ventilation system, eco V
is the solution for improving your indoor air quality.
• High Efficiency Heat Exchanger
• Bypass Ventilation
• Strong Filter Function
• Flexibility of Installation
• Easy Cleaning and changeable Filter
Power Supply [Ø,V,Hz] _1Ø, 220-240V, 50Hz
Dimension [WxHxD]_204x509x509mm[8.03x23.23x23.23inch]
Weight_ 24kg[52.91lb]
Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50Hz
Dimension (WxHxD) _ 590x204x590mm (23.23x8.03x23.23 inch)
Weight _ 24kg (52.91 lb)]
Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50Hz
Dimension (WxHxD) _ 596x320x640mm (23.46x12.60x25.20 inch)
Weight _ 27kg (59.51 lb)
Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50Hz
Dimension (WxHxD) _ 988x273x1014mm (38.9x10.75x39.92 inch)
Weight _ 45kg (99.2 lb)
Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50HzDimension (WxHxD) _ 988x273x1014mm (38.9x10.75x39.92 inch) Weight _ 52kg (114.7 lb)
Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50HzDimension (WxHxD) _ 1062x365x1140mm (41.9x14.4x44.9 inch) Weight _ 67kg (147.7lb)
Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50HzDimension (WxHxD) _ 1062x365x1140mm (41.9x14.4x44.9 inch) Weight _ 67kg (147.7lb)
Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50Hz Dimension (WxHxD) _ 1313x737x1140mm (51.7x28.8x44.9 inch) Weight _ 146kg (321.9 lb)
Power Supply (Ø, V, Hz) _ 1Ø, 220~240V, 50HzDimension (WxHxD) _ 1313x737x1140mm (51.7x28.8x44.9 inch)Weight _ 146kg (321.9 lb)
LZ-H0106BA0 LZ-H0156BA0
LZ-H0356BA0 LZ-H0256BA0
LZ-H0506BA0
LZ-H0806BA0
LZ-H1006BA0
LZ-H1506BA0
LZ-H2006BA0
LG A
ir Conditioners System
70_
71 (H
eat Recovery ventilator)
eco V ensures the fresh enviroment in your life!Heat Recovery Ventilator
* Specifications
LZ-H0106BA0
100(28)
1, 220-240, 50
SUPER-HIGH/HIGH/LOW
0.32/0.3/0.28
68/60/50
100/100/90(59/59/53)
40/35/30(0.16/0.14/0.12)
78/78/80
68/68/70
58/58/60
28/26/20
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
Crossflow
24(52.91)
590x204x590(23.23x8.03x23.23)
4
Ø100(Ø3.94)
1
Direct-Drive
1
Direct-Drive
2
Cleanable
580x10x113(22.83x0.39x4.45)
LZ-H0156BA0
150(42)
1, 220-240, 50
SUPER-HIGH/HIGH/LOW
0.36/0.36/0.35
83/80/78
150/150/100(42/42/28)
70/55/45(0.28/0.22/0.18)
75/75/79
62/62/69
55/55/59
32/30/22
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
Crossflow
24(52.91)
590x204x590(23.23x8.03x23.23)
4
Ø100(Ø3.94)
1
Direct-Drive
1
Direct-Drive
2
Cleanable
580x10x113(22.83x0.39x4.45)
LZ-H0256BA0
250(69)
1, 220-240, 50
SUPER-HIGH/HIGH/LOW
0.55/0.5/0.34
130/115/80
250/250/180(69/69/50)
65/50/40(0.26/0.2/0.16)
80/80/85
70/70/78
64/64/68
32/28/21
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
- / - / -
Crossflow
27(59.51)
596x320x640(23.46x12.60x25.20)
4
Ø150(Ø5.91)
1
Direct-Drive
1
Direct-Drive
2
Cleanable
580x10x175(23.23x0.39x6.89)
LZ-H0356BA0
350(97)
1, 220-240, 50
SUPER-HIGH/HIGH/LOW
1.40/1.33/0.9
205/195/170
350/350/210(97/97/58)
170/88/40(0.68/0.35/0.16)
83/83/87
80/80/85
78/78/83
33/28/23
SUPER-HIGH/HIGH/LOW
1.40/1.33/0.9
205/195/170
350/350/210(97/97/58)
170/88/40(0.68/0.35/0.16)
- / - / -
- / - / -
- / - / -
33/28/23
Crossflow
45(99.20)
988x273x1014(38.9x10.75x39.92)
4
Ø200(Ø7.87)
1
Direct-Drive
1
Direct-Drive
2
Cleanable
855x10x166(33.66x0.39x6.54)
Unit
CMH(L/S)
Ø,V,Hz
-
Amps
W
CMH(L/S)
Pa(in.wg)
%
%
%
dBA
-
Amps
W
CMH(L/S)
Pa(in.wg)
%
%
%
dBA
-
kg(lb)
mm(inch)
EA
mm(inch)
EA
-
EA
-
EA
-
mm(inch)
Step
Current
Power Input
Air Flow
External Static Pressure
Temperature Exchange Efficiency
Enthalpy Exchange Efficiency
Noise Level(Sound Level, 1.5m)
Step
Current
Power Input
Air Flow
External Static Pressure
Temperature Exchange Efficiency
Enthalpy Exchange Efficiency
Noise Level(Sound Level, 1.5m)
Item
Nominal Capacity
Power Supply
Heat Exchanger
Weight
Dimension
Duct work
Supply Air Fan
Exhaust Air Fan
Filters
LZ-H0506BA0
500(139)
1, 220~240, 50
SUPER-HIGH/HIGH/LOW
1.51/1.39/1.06
260/225/200
500/500/320(139/139/89)
150/60/28(0.60/0.24/0.11)
75/75/79
75/75/80
70/70/75
34/32/25
SUPER-HIGH/HIGH/LOW
1.51/1.39/1.06
260/225/200
500/500/320(139/139/89)
150/60/28(0.60/0.24/0.11)
- / - / -
- / - / -
- / - / -
34/32/25
Crossflow
52(114.7)
988x273x1014(38.9x10.75x39.92)
4
Ø200(Ø7.87)
1
Direct-Drive
1
Direct-Drive
2
Cleanable
855x10x166(33.66x0.39x6.54)
Notes:1. eco mode - Enthalpy Heat Recovery Ventilation mode2. Noise level : - The operating conditions are assumed to be standard. - Sound measured at 1.5m below the center the body. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed.
eco
V M
ode
Byp
ass
Mod
e
SH/H/L
SH/H/L
SH/H/L
SH/H/L
SH/H/L
Heating(SH/H/L)
Cooling(SH/H/L)
SH/H/L
SH/H/L
SH/H/L
SH/H/L
SH/H/L
SH/H/L
Heating(SH/H/L)
Cooling(SH/H/L)
SH/H/L
Type
WxHxD
Qty
Size(Ø)
Qty
Type
Qty
Type
Qty
Type
Size(WxHxD)
* Specifications
Unit
CMH(L/S)
Ø,V,Hz
-
Amps
W
CMH(L/S)
Pa(in.wg)
%
%
%
dBA
-
Amps
W
CMH(L/S)
Pa(in.wg)
%
%
%
dBA
-
kg(lb)
mm(inch)
EA
mm(inch)
EA
-
EA
-
EA
-
mm(inch)
Item
Nominal Capacity
Power Supply
Heat Exchanger
Weight
Dimension
Duct work
Supply Air Fan
Exhaust Air Fan
Filters
LZ-H1006BA0
1000(278)
1, 220~240, 50
SUPER-HIGH/HIGH/LOW
3.0/2.9/2.6
560/540/470
1000/1000/800(278/278/222)
160/90/50(0.80/0.44/0.24)
75/75/78
66/66/71
61/61/66
37/35/31
SUPER-HIGH/HIGH/LOW
2.8/2.7/2.4
560/540/470
1000/1000/800(278/278/222)
160/90/50(0.80/0.44/0.24)
- / - / -
- / - / -
- / - / -
37/35/31
Crossflow
67(147.7)
1062x365x1140 (41.9x14.4x44.9)
4
Ø250(Ø9.54)
1
Direct-Drive
1
Direct-Drive
2
Cleanable
1056x10x212.5(41.57x0.39x8.37)
LZ-H1506BA0
1500(417)
1, 220~240, 50
SUPER-HIGH/HIGH/LOW
5.6/5.4/5.2
950/925/795
1500/1500/1200(417/417/333)
200/110/60(0.80/0.44/0.24)
79/79/82
70/70/75
65/65/70
39/37/33
SUPER-HIGH/HIGH/LOW
5.6/5.4/5.2
950/925/795
1500/1500/1200(417/417/333)
200/110/60(0.80/0.44/0.24)
- / - / -
- / - / -
- / - / -
37/35/31
Crossflow
146(321.9)
1313x737x1140(51.7x28.8x44.9)
4+2
Ø250(Ø9.54)+Ø350(Ø13.77)
2
Direct-Drive
2
Direct-Drive
4
Cleanable
1056x10x212.5(41.57x0.39x8.37)
LZ-H2006BA0
2000(556)
1, 220~240, 50
SUPER-HIGH/HIGH/LOW
6.0/5.8/5.2
1020/970/860
2000/2000/1600(556/556/444)
160/90/50(0.80/0.44/0.24)
75/75/78
66/66/71
61/61/66
39/37/33
SUPER-HIGH/HIGH/LOW
5.6/5.4/4.8
1020/970/860
2000/2000/1600(556/556/444)
160/90/50(0.80/0.44/0.24)
- / - / -
- / - / -
- / - / -
37/35/31
Crossflow
146(321.9)
1313x737x1140(51.7x28.8x44.9)
4+2
Ø250(Ø9.54)+Ø350(Ø13.77)
2
Direct-Drive
2
Direct-Drive
4
Cleanable
1056x10x212.5(41.57x0.39x8.37)
LZ-H0806BA0
800(222)
1, 220~240, 50
SUPER-HIGH/HIGH/LOW
2.8/2.7/2.6
405/360/320
800/800/660(222/222/183)
200/110/60(0.80/0.44/0.24)
79/79/82
70/70/75
65/65/70
36/34/30
SUPER-HIGH/HIGH/LOW
2.8/2.7/2.6
405/360/320
800/800/660(222/222/183)
200/110/60(0.80/0.44/0.24)
- / - / -
- / - / -
- / - / -
36/34/30
Crossflow
67(147.7)
1062x365x1140 (41.9x14.4x44.9)
4
Ø250(Ø9.54)
1
Direct-Drive
1
Direct-Drive
2
Cleanable
1056x10x212.5(41.57x0.39x8.37)
Notes:1. eco mode - Enthalpy Heat Recovery Ventilation mode2. Noise level : - The operating conditions are assumed to be standard. - Sound measured at 1.5m below the center the body. - Sound level will vary depending on a range of factors such as the construction(acoustic absorption coefficient) of particular room in which the equipment is installed.
eco
V M
ode
Byp
ass
Mod
e
Step
Current
Power Input
Air Flow
External Static Pressure
Temperature Exchange Efficiency
Enthalpy Exchange Efficiency
Noise Level(Sound Level, 1.5m)
Step
Current
Power Input
Air Flow
External Static Pressure
Temperature Exchange Efficiency
Enthalpy Exchange Efficiency
Noise Level(Sound Level, 1.5m)
SH/H/L
SH/H/L
SH/H/L
SH/H/L
SH/H/L
Heating(SH/H/L)
Cooling(SH/H/L)
SH/H/L
SH/H/L
SH/H/L
SH/H/L
SH/H/L
SH/H/L
Heating(SH/H/L)
Cooling(SH/H/L)
SH/H/L
Type
WxHxD
Qty
Size(Ø)
Qty
Type
Qty
Type
Qty
Type
Size(WxHxD)
LG A
ir Conditioners System
72_73
V-net Line up
Remote Controller
Central Controller
Wireless RemoteController
Simple Central Controller
Wired RemoteController
AC Smart &128 Unit Expansion Kit
Accessory
Simple
Standard
Deluxe
PQWRHDF0
PQRCUCSOCPQRCFCSOC
PQRCUSA1
PQRCUDS0 (White)PQRCUDS0B (Blue)PQRCUDS0S (Silver)
PQCSB101S0PQCSB101S0+PQCSC101S0PQCSB101S0+PQCSD130A0
PQCSW320A0E
& Accessory(LG Network Solution)
& Accessory
Remote Controller
Central Controller
Accessory
74
76
84
V- n e t & A c c e s s o r yPDI, Remote temperature sensor, Dry contact, Cool/Heat selector, DO KitVentilation Kit (4Way Cassette), AHU Control kit & EEV kit, Refrigerant Charging KitAir guide, Suction grille and canvas, Heat recovery unit, Header, Y branch
(Function controller) (Scheduler)
ACP&AC ManagerPQCPA11A0E(Without IO)PQCPB11A0E(With IO)PQCSS520A0E(AC Manager)
BNU
PQNFB17B0(BACnet)
PQNFB16A1( )
PQCSE440U0
LG A
ir Conditioners System
74_
75
* Wireless Remote Controller
Simple
Operating modeMode changeRoom tempPlasmaAuto swingChild lock
On_Off / Fan speed / Mode / Temp.Cooling / Heating / Fan
√√√√
PQRCUCSOC
Simple for Hotel
PQRCFCSOC
PQWRHDF0
Features PQRCUCSOC
Operating modeMode changeRoom tempPlasmaAuto swingChild lock
On_Off / Fan speed / Temp.Impossible
√√√√
Features PQRCFCSOC
Features PQWRHDF0
On_Off / Fan speed / Mode / Temp.√√√√
MULTI V SYNC II
Operating modeRoom temperature checkingChaos swing / Jet coolOn_Off timerSleep mode autoMain / Sub setting of indoor units ΔT setting (for Auto Changeover)
* Wired Remote Controller for Air-conditioner
Standard (WIDE)
PQRCUSA1
Features PQRCUSA1
& Accessory
Remote ControllerOur air conditioning system can be controlled by various types of remote controllers providing general control to unique function.
Remote Controller•Wired Remote Controller
•Simple Wired Remote Controller
•Wireless Remote Controller
* Wired Remote Controller for
Standard
Features PZRCUSB0
On / Off LEDVentilation mode settingRapid ventilationPower saving ventilationReservationElectric failure compensationChild lock
√√√√
Weekly / Simple Max. 2 hours
√
* Simple Wired Remote Controller
Deluxe
PQRCUDS0 (White) PQRCUDS0B (Blue)PQRCUDS0S (Silver)
Features PQRCUDS0, PQRCUDS0B, PQRCUDS0S
On_Off / Fan speed / Mode / Temp.√√√√√
Weekly / Simple√√
Operating modeTouch screen / LCD bak_lightRoom temp.Fan / Plasma / Swirl / HeaterVane control / Auto swing E.S.P functionReservationTimer functionChild lock
Operating modeOn / Off LEDRoom temp.Fan / Plasma / Swirl / HeaterVane control / Auto swing / Fan autoE.S.P functionReservationTimer functionChild lockElectric failure compensationWireless remocon receiverMaster setting of indoor unitsΔT setting (For Auto Changeover)2 Controllers to 1 indoor units
On_Off / Fan speed / Mode / Temp.√√√√√
Weekly / Simple√√
Max. 2 hours√
MULTI V SYNC II
Optional function Plasma / Heater / HumidifierOperating air volume
: Applicable for only MULTI V II SERIES
PZRCUSB0
: Applicable for only MULTI V II SERIES
LG A
ir Conditioners System
76_
77
AC Smart & 128 Unit Expansion KitFor the mid sized buildings up to 64 or 128 indoor units can be controlled and monitored by touch screen central controller. It’s possible to control and monitor the air conditioning system through web access, anywhere with computer.
PQCSW320A0E
• Combination
RS4851.25mm2 X 2C
(shield)
AC220V
PMNFP14A0 (Max. 16 Indoors)PMNFP14A1 (Max. 48 Indoors)
PMNFP14A0
PHNFP14A0 (Ceiling & Floor, Duct)PSNFP14A0 (CST, RAC)
PHNFP14A0
DC Comm, LineAC Smart
PQCSW320A0E
PQCSB101S0PQCSC101S0
Function Controller & SchedulerIt is possible to control, monitor and schedule the operation of indoor units by using these controllerin company with a simple central controller
PQCSB101S0
Simple Central Controller• A central controller for managing small sites• Control up to 16 indoor units
Max. no of indoor units
Individual control
Lock function
Mode change
Malfunction indicator
Dimension(mm)
Power(V)
16 indoor units
On_Off Control
Total / Individual
Cooling / Heating
LED lamp
120 x 120 x 20
DC 10V
Features PQCSB101S0
& Accessory
* 1 Function controller combined with max. 8 simple central contollers.
Features PQCSB101S0+PQCSC101S0
16 indoor units
On_Off / Fan speed / Mode / Temp.
Total / Individual
Cooling / Heating / Fan
Error display on LCD
Weekly
(120x120x20)+(120x133x20)
DC 10V
16 indoor units
On_Off / Fan speed / Mode / Temp.
Total / Individual
Cooling / Heating / Fan
Error display on LCD
-
(120x120x20)+(70x120x14)
DC 10V
Max. no of indoor units
Individual control
Lock function
Mode change
Malfunction indicator
Schedule
Dimension(mm)
Power(V)
PQCSB101S0+PQCSD130A0
PQCSB101S0PQCSD130A0
*128 Indoor unit Expansion Kit: PQCSE440U0*DO Kit : PQNFP00T0
PI485
PQCSE440U0
Single constant
Eco-V
Single A, MULTI
MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI
MULTI V PLUSMULTI V SYNCMULTI V SPACE
LG A
ir Conditioners System
78_
79 &
Accessory
ACP (Advanced Control Platform)
PQCPA11A0E (Without IO)PQCPB11A0E (With IO)
• Through embedded web control function in ACP one can control and monitor various functions of air-conditioner such as temperature setting, schedule, peak power control, etc.
• Features
Application
Multi Area ManagementThe product specially designed for multi area management.-Central control & monitor Max. 4,096 indoor units & Max.16 ACP
Max. 4,096 Indoor
ACP AC ManagerKorean reference site.
ACP&AC Manager• AC Manager is suitable for large site because AC Manager is the S/W that can control Max. 16 ACP (Max.4,096 indoor units).
PQCPA11A0E (Without IO)PQCPB11A0E (With IO)
PQCSS520A0E (AC Manager)
PQCPA(B)11A0E
Max.no. of indoor units
Control / Monitoring
Schedule management
Lock function
Temperature range restriction
Temperature limit function
Auto Changeover function
History function
Peak control
PDI monitoring
Interlocking function
Printing function
256 indoor units
√
√
Temperature
-
-
-
Monitoring
√
Need of PDI
-
-
4,096 indoor units(16 ACP)
√
√
Mode/Temp/Fan speed/Schedule
√
√
√
Monitoring & Error history
√
Need of PDI
-
System setting, History, PDI
4,096 indoor units(16 ACP)
√
√
Mode/Temp/Fan speed/Schedule
√
√
√
Monitoring & Error history
√
Need of PDI
Fire sensor, Door sensor, Motion sensor...
System setting, History, PDI
PQCPA11A0E+PQCSS520A0E PQCPB11A0E+PQCSS520A0E
ACP ACP (without IO) + AC Manager ACP (with IO) + AC Manager
Application
• Combination
AC ManagerPQCSS520A0E
Internet
AC220V
PHNFP14A0 (Ceiling & Floor, Duct)PSNFP14A0 (CST, RAC)
PMNFP14A0
PMNFP14A0 (Max. 16 Indoors)PMNFP14A1 (Max. 48 Indoors)
Single constant
Eco-V
Single A, MULTI
DC Comm, Line
MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI
MULTI V PLUSMULTI V SYNCMULTI V SPACE
HUB
RS4851.25mm2 X 2C
(shield)
LANPI485
PHNFP14A0
PI485
LG A
ir Conditioners System
80
_8
1 &
Accessory
• Combination
DO Kit• Do Kit is connected between ACP (AC Smart) and external devices. So ACP(AC Smart) can start and stop external devices such as light, pump, motor, etc.
PQNFP00T0
• Features - Accumulated total power consumption indicated - Accumulated / Current power consumption of each indoor units indicated - Accumulated power consumption by month indicated - Max connectable no. of indoor units : 48 indoor units - 1 PDI per 1 outdoor unit - Power failure-proof function : Data back up on EEPROM even if power turns off - Connectable to PC based central controller
- Simple connection with the remote metering system (RS485 approach)
• Combination
PQNUD1S00
Pulse output (1,2, 4,6,8,10W/pulse)AC 200V~240V 50/60Hz
Digital WHM(Local purchase)
AC220V
RS485
PDI (Power Distribution Indicator)
• This device is an indicator for power consumption of the multi type air-conditioner used for common power line.
PQNUD1S00
or
* In the case of MULTI V II SERIES, don’t need PI 485
PI485
Power of LoadBUS _ A
BUS _ B
L N
Web Access - Remote Management - Error Report via E-mail
Operation Report-Operating Time, Percentage, History
Emergency Interlock-Forced Off
128 Indoor unitsExpansion Kit
Multiple Local Controllers-Master / Slave
Multi Language-English, Italian, Spanish, French, German, Dutch, Russian
Easy Control-Function Lock-Lock Schedule
Comfort Control-Automatic H/C Changeover-Temperature Limit-Temperature Range Restriction-Time Limit Control
AC Smart• 7" Touch Screen / GUI
• Direct Connect to LGAP
DO Kit
• Remote Controller Restriction• Automatic Setting• A/C and Vent.
Easy Software Upgrade by USB
DI RS485
USB
Screen Saver
EmergencyLGAP
Light Pump Motor etc
Cooling
Heating
ACP or AC Smart
LG A
ir Conditioners System
82_
83
• Features - Through embedded web control function in BACnet one can access the airconditioner and external devices through internet. - It can control 256 indoor units. ( A/C or Ventilator ) - External devices such as fire alarm, motion detector can be connected to gateway and their function can be interlinked with airconditioner operation.
• Combination
& Accessory
PQNFB17B0
BNU-BAC Gateway (Building Network Unit- BACnet)
Easy interface between BMS and LG air conditioner- Independence of BMS under the standard BMS : Operation system based on BACnet Service.
Controlling Monitoring items
On/Off command
Operation mode setting
Fan speed setting
Lock setting
Air flow setting
Set temp. setting
User mode setting (for only ventilator)
On/Off status report
Operation mode status report
Fan speed status report
Lock status report
Air flow status report
Current space temp. status report
Error status report
User mode status report(for only ventilator)
• Combination
• Features - Connection to using LONTALK protocol and LG Air-conditioner protocol
- Process ability • 64 units( including indoors and ventilators) • Valid address for each unit : 0x00 ~ 0x3F
- Self installation verification function using internet (Web server included) • Setting gateway • Diagnosis of communication status on LG Air-conditioner network
- Connection to remote total management system (LG system)
PQNFB16A1
BNU-LW Gateway (Building Network Unit- )
Easy interface between BMS and LG air conditioner- Independence of BMS under the standard BMS : Operation system based on LNS ( network service) - No network installation needed - Very widely applicable protocol( )
NetworkBMS system
PHNFP14A0
Lighting control
Other LON devicesIndoor unit : Max. 64 units (Air-conditioner & ventilation)Indoor address : 00 ~ 3F
Remote checking Utility control
LGAP applied Air-conditioner
Outdoor unit Indoor unit
BNU-LWPQNFB16A1
LON comm. line
Simple centralcontroller
or
AC Smart
PI485
PI485
Controlling Monitoring items
On/Off command
Operation mode setting
Fan speed setting
Lock setting
Air flow setting
Set temp. setting
User mode setting (for only ventilator)
On/Off status report
Operation mode status report
Fan speed status report
Lock status report
Air flow status report
Set temp. status report
Current space temp. status report
Error status report
User mode status report(for only ventilator)
PI485PMNFP14A0
PMNFP14A0 (Max. 16 Indoors)PMNFP14A1 (Max. 48 Indoors)
BACnetNetwork
BMS system
PHNFP14A0
LGAP applied Air-conditioner
Outdoor unit
Lighting control
Other BACnet devicesIndoor unit : Max. 256 units (Air-conditioner & ventilation)Indoor address : 00 ~ FF
Remote checking Utility control
BNU-BACPQNFB17B0
BACnet comm. line
Indoor unitSimple centralcontroller
or
AC Smart
PI485
PI485
PI485
PMNFP14A0
PMNFP14A0 (Max. 16 Indoors)PMNFP14A1 (Max. 48 Indoors)
Eco-V
Single A, MULTI
MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI
MULTI V PLUSMULTI V SYNCMULTI V SPACE
Eco-V
Single A, MULTI
MULTI V PLUS IIMULTI V SYNC IIMULTI V SPACE IIMULTI V MINI
MULTI V PLUSMULTI V SYNCMULTI V SPACE
RS4851.25mm2 X 2C
(shield)
RS4851.25mm2 X 2C
(shield)
Mode Change
Heating
Fan Mode
Cooling
LG A
ir Conditioners System
84
_8
5
• Combination
& Accessory
• Features - Indoor unit control without central controller - Select operation mode : Cooling, Heating, Fan mode - Mode lock for cooling & heating mixing error-proof during the change of season.
Cool/Heat SelectorThis switch enables selection of heating, cooling or fan mode. So it can prevent that cooling & heating mixing error occurs during the change of season.
PRDSBM
* PRDSBM is applicable for only MULTI V II Series.
Fresh air can be supplied from outside through this ventilation kit.
PTVK410 PTVK420 PTVK430
Ventilation Kit (4Way Cassette)
• Accessory• Installation Bracket• Bolt• Screw
• Dimension
• Models applied to
• Wiring diagram 1. Wire to the control box in the indoor unit by removing the existing thermistor and connect the extension cable its place. 2. Cut the extension cable to the appropriate length and connect the screw terminal of the remote sensor. 3. In the case of wired remote controller installed, set the temperature sensing slide s/w at MAIN mode.
Connector
Remote temperature sensor
Extension cable
Screw terminal connection
Indoor unit
Remote Temperature SensorIt can help to detect the exact room temperature at the optimal position.
• Model applied to Cassette, Duct type.• Part supplied - Remote temperature sensor - Cable (15m) - ManualPQRSTA0
PQDSB(A) / PQDSB1 / PQDSBC
Dry Contact module• It is connected between indoor units and external device, so it can be used for various purpose.
* PQDSBC is applicable for only MULTI V II Series.
• Features
√
√
√
√
√
√
√
√
√
√
Contact point
PQDSA(B) PQDSB1 PQDSBC
Voltage / Non voltage input
On_Off control
Lock / Unlock
Fan speed setting
Thermo off
Energy saving
Expected temperature setting
Error Monitoring
Operation monitoring
Power input
1 contact point
AC 220V from outside power source
√
√
√
1 contact point
AC 24V from outside power source
2 contact points
DC 5V&12V from indoor unit PCB
√
√
• Ceiling Cassette - 4Way (24k ~ 48k Btu/h)
LG A
ir Conditioners System
86
_8
7 &
Accessory
Refrigerant Charging Kit
PRAC1
• Procedure 1. Arrange manifold, refrigerant charging kit, refrigerant vessel and scale 2. Connect manifold to the gas pipe service valve of outdoor uint as shown in the figure. 3. Connect manifold refrigerant charging kit. Use designated refrigerant charging kit. If designated refrigerant charging kit isn’t used, the system may get damaged. 4. Connect refrigerant charging kit and refrigerant vessel. 5. Purge hose and manifold. 6. After “568” is displayed, open the valve and charge the refrigerant
• Error contents about auto refrigerant charging function
1. “329”: Temperature range error (In case that indoor unit or outdoor unit is out of range) 2. “339”: Low pressure descent error (In case the system runs at low pressure limit for over 10 minutes) 3. “349”: Rapid refrigerant inflow (In case the liquid refrigerant flows in because of not using designated refrigerant charging kit) 4. “359”: Instability error (In case the high/low pressure target doesn’t get satisfied for some time after the starting operation)
• Application • Dimension
133
69
202Manifold
Refrigerant
Refrigerant Charging Kit
AHU Control Kit & EEV KitFresh air can be supplied from outside connecting AHU to Multi V Plus II.
PRCKA0 PRLK048A0
• Specifications
Control KitEEV Kit
NETPOWERModel Name
Gross W H D
Weight(kg) Dimension(mm)
PRCKA0PRLK048A0
2.233.1
3.63.6
280404.2
13583
280217
220~240V / 50HZ / 1Pha
When selecting evaporator, Change ‘Option PCB’ in EEV kit according to below table(Basic ‘Option PCB is for 36k Btu/h )
• Selection of evaporator
Option PCB P/No Capacity (Btu/h)
Allowed heat exchanger Volume (dm3/hr)
Allowed heat exchanger capacity (kW)
EBR52358907
EBR52358908
EBR52358909
EBR52358910
EBR52358911
EBR52358912
28k
36k
42k
48k
76k
96k
1.22~1.53
1.53~1.91
1.91~2.14
2.14~2.67
3.06~3.82
3.82~4.78
7~9
9~11
11~13
13~16
20~24
25~31
* Saturated Suction Temperature (SST) = 6ºC, SH (Superheat)=5k, Air Temperature = 27ºC DB / 19ºC WB
(Main PCB)
Detail
Capacity setting'Option PCB'
• Wiring diagram
Single
Pipe
Themistor Return Air
Supply Air
(PRAC1)
LG A
ir Conditioners System
88
_8
9
Indoor unit
Outdoor unit
2
26
26
19
801x218x617
9.52(3/8)
19.05(3/4)
19.05(3/4)
Max. connectable number of indoor units
Max. connectable capacity of indoor units (Per port/unit) kW
Nominal Input cooling W
heating W
Net weight kg
Dimensions (WxHxD) mm
Piping Indoor liquid mm(inch)
connections unit gas mm(inch)
Outdoor liquid mm(inch)
unit low pressure mm(inch)
high Pressure mm(inch)
Power supply Ø/V/Hz
3
40
40
20
801x218x617
12.7(1/2)
28.58(1 1/8)
22.2(7/8)
4
40
40
21
801x218x617
12.7(1/2)
28.58(1 1/8)
22.2(7/8)
9.52(3/8)15.88(5/8)
1/220 ~ 240/50
PRHR020 PRHR030 PRHR040
14.1 / 47
• Specifications
PRHR020(2 Pipe-connection)
PRHR030(3 Pipe-connection)
• Combination
& Accessory
Heat recovery unit (Applied to MULTI V SYNC II R410A)
• Max. 4 indoor units can be connected by module design.
• Due to the automatic search algorithm for piping detection, easy installation and effectiveness is improved.
• Subcooling cycle in HR unit makes the system efficiency maximum.
PRHR040(4 Pipe-connection)
• Application • Dimension
• Features - High external static pressure facilitates unit use with flexible ducts of varying lengths. - When using suction panel, unit requires only 270mm of ceiling space. - Blends unobtrusively with any interior decoration.
PBSGB30
PBSGB40
A B C
910
1188
359
359
56
56
PBSC30
PBSC40
A B C
821
1100
274
274
42~250
42~250
• Models applied to - Ceiling concealed duct _ Built-in type
Type
√
√
Capacity (Btu/h)
7kModel
Grille
Canvas
PBSGB30PBSGB40
PBSC30PBSC40
√
√
√
√√
√
√
√
9k 12k 15k 18k 24k
√
√
C
A
B A
B
C
PQAGA
Air Guide• Used to control the direction of air discharge by outdoor unit.
• Converts vertical discharge into horizontal discharge.
• Dimension
Suction Grille and Canvas• High flexibility for a wide variety of applications
PBSGB30 / PBSGB40PBSC30 / PBSC40
If you need a highly efficient air condition-ing system in your building, MULTI V is the right choice for you.
Auto Clean
4-Way Air Deflection
Swirl Swing
Auto Restart
Sleep Mode Auto Operation
Weekly Program Wired remote controller only
Two Thermistor Control Wired remote controller only
Changable Panel
Second Remote Control
NEO Plasma Air Purifying System
Jet Cool
Child Lock Function Wired remote controller only
Healthy Dehumidification
Hot Start (Heat pump only)
Soft Dry Operation Mode
Low Standby Power
Group Control Wired remote controller only
Auto Changeover MULTI V SYNC model only
( )
( )
( )
( )
( )
LG A
ir Conditioners System
90
_9
1 &
Accessory
* MULTI V PLUS II, MULTI V MINI, MULTI V SPACE II
Model ModelGas Pipe Liquid Pipe Gas Pipe Liquid Pipe
(unit:mm) (unit:mm)
ARBLN07121
ARBLN14521
* MULTI V SYNC II
Model Low Pressure Gas Pipe Liquid Pipe
(unit:mm)
ARBLB01621
High Pressure Gas Pipe
ARBLB03321
ARBLB07121
ARBLB14521
Y Branch pipe for connection of indoor units
ARBLN01621
ARBLN03321
* MULTI V SYNC II (2 Outdoor units)
Model Low Pressure Gas Pipe
Liquid Pipe
(unit:mm)
ARCNB20
High Pressure Gas Pipe
* MULTI V SYNC II (3 Outdoor units)
Model Low Pressure Gas Pipe
Liquid Pipe
(unit:mm)
ARCNB20
High Pressure Gas Pipe
ARCNB30
Header for connection of indoor units
Y Branch pipe for connection of outdoor units
Model
4 branchARBL054
7 branchARBL057
4 branchARBL104
Model
7 branchARBL107
10 branchARBL1010
10 branchARBL2010
Gas Pipe Liquid Pipe Gas Pipe Liquid Pipe
(unit:mm) (unit:mm)
* MULTI V PLUS II (2 Outdoor units)
Model
ARCNN20
Model
ARCNN20
ARCNN30
Connection of Gas Pipe Connection of Liquid Pipe Connection of Gas Pipe Connection of Liquid Pipe
(unit:mm) (unit:mm)
* MULTI V PLUS II (3 Outdoor units)
* MULTI V PLUS II, MULTI V MINI, MULTI V SPACE II